HomeMy WebLinkAboutUtilities 2015-05-12 COMPLETE AGENDA PACKETCity of Tukwila
Utilities Committee
❖ Dennis Robertson, Chair
❖ Verna Seal
❖ De'Sean Quinn
AGENDA
Distribution:
P. Brodin
D. Robertson
R. Turpin
V. Seal
M. Hart
D. Quinn
Clerk File Copy
K. Kruller
2 Extra
Mayor Haggerton
Pg. 1
D. Cline
e-mail cover to: A. Le,
L. Humphrey
C. O'Flaherty, D.
B. Giberson
Robertson, D. Almberg,
F. Iriarte
B. Saxton, S. Norris,
R. Tischmak
M. Hart, L. Humphrey
G. Labanara
Pg. 15
TUESDAY, MAY 121 2015 — 5:30 PM
FOSTER CONFERENCE ROOM
(formerly known as CR #1) in the 6300 Building
Item
Recommended Action
Page
1. PRESENTATION(S)
2. BUSINESS AGENDA
a) Duwamish Gardens
a) Forward to 5/18/15 Regular
Pg. 1
Grant Amendment — Recreation and Conservation Office
Consent Agenda
b) Duwamish Gardens
b) Forward to 5/18/15 Regular
Pg. 9
Bid Award
c) CBD Sanitary Sewer Rehab - APW to APE Sewer Repair
c) Forward to 5/18/15 Regular
Pg. 15
Change Order No. 3
Consent Agenda
d) CBD Sanitary Sewer Rehabilitation - Construction
d) Forward to 5/18/15 Regular
Pg. 19
Project Completion and Acceptance
Consent Agenda
3. ANNOUNCEMENTS
4. MISCELLANEOUS
Future Agendas:
Next Scheduled Meeting: Wednesday, May 27, 2015 (due to holiday)
SThe City of Tukwila strives to accommodate individuals with disabilities
Please contact the Public Works Department at 206 - 433 -0179 for assistance.
Utilities Committee - 2015 Work Plan
Description
Qtr
Dept
Action or
Briefing
Status
Andover Park West /Strander New Water Main
Closeout with the TUC Transit Center
3
PW
A
58th Avenue South Water Main Replacement
Bid award
4
PW
A
Macadam Road South Water Upgrade
Design contract
PW
A
Fort Dent Sewer Relocation
Design contract (301 Fund)
1
PW
A
3/16 Consent
Andover Park E Water Main Replacement
Sewer Component
2
PW
A
Road Component
2
PW
A
Annual Sewer Repair Program
Bid award
2
PW
A
CBD Sanitary Sewer Rehab
Bid award
2
PW
A
Closeout
3 -4
PW
A
CBD Sewer Repair
Update & Closeout
1
PW
B
Sewer Lift Station #2 Upgrades
Bid award
2
PW
A
Sewer Repair West of Strander Blvd Bridge
Bid award
3
PW
A
Andover Park East Sewer Replacement
Design consultant
4
PW
A
Annual Small Drainage Program
Bid award
2
PW
A
2016 program design contract
4
PW
A
NPDES
Annual update
3
PW
B
Complete 3/10
E. Marginal Way S Stormwater Outfalls Construction
Grant acceptance
4
PW
A
East Marginal Way S Storm Pipe Replacement Construction
Status update & Closeout
4
PW
B
Tukwila 205 Levee Certification Phase 1
Funding Options (per Budget work shop)
2
PW
B
Chinook Wind
Design consultant
PW
A
OTHER
Water Asset Management Briefing
4
PW
B
King County Grant for Recycling Assistance - DCD
1
DCD
A
Complete 2/2
Briscoe Desimone Levee Update — City of Kent
1
PW
B
Zayo Franchise Agreement
1 1
PW
A
Complete
Utility Comprehensive Plan Review
1 -4
PW
B
In Progress
Standard Reports /Briefings
Frequency
Dept.
Facility Tours
As needed
PW
Waste Management Update I
Annual
PW (Complete 3110)
Committee Work Plan
2X
Council, Staff
City of Tukwila Updated 4/30/15
City of Tukwila
Jim Haggerton, Mayor
TO: Mayor Haggerton
Community Affairs and Parks Committee
Utilities Committee
FROM: Bob Giberson, Public Works Director.."o
By: Ryan Larson, Senior Program Manager
DATE: May 8, 2015
SUBJECT: Duwamish Gardens
Project No. 90630102, Agreement No. 14-102
Grant Amendment — Recreation and Conservation Office
ISSUE
Approve a grant amendment with the Washington State Recreation and Conservation Office
(RCO) for additional construction funding for the Duwamish Gardens Project.
BACKGROUND
The City acquired the Duwamish Gardens site in 2008 for future restoration as a salmon
habitat site with minor park elements. The project's design and permitting are complete and
construction is anticipated to begin this spring.
The City entered into Agreement No. 14-102 with the RCO to provide $949,434 in
construction funding for Duwamish Gardens. This RCO grant requires a total of $301,523.00
in matching funds which can come from any combination of other available funding.
Staff reviewed the total construction funds available and compared this with the final
construction estimate prior to project bidding and determined that the project had insufficient
construction funding. Staff contacted the RCO about the need for additional construction
funding to allow the project to be advertised and was able to secure an additional $250,000 in
RCO funding.
ANALYSIS
The RCO developed a grant amendment that will provide the additional $250,000 in
construction funding for Duwamish Gardens. With this increased funding level, the City is
required to provide $80,000 in additional matching funds, bringing the total RCO match
requirement to $381,523. As with the previous grant agreement, these funds can be matched
using any other non-RCO grant or City funds. A total of $1,416,990 is available in non-RCO
grant funding, which covers the total RCO match requirement. The other grant funding is from
King County Conservation Futures, King Conservation District, and the King County Flood
Control District (for $1.265m).
1; 110141 U, 161:4
Council is being asked to approve a grant amendment with the RCO for an additional grant
funding amount of $250,000 for the Duwamish Gardens Project and consider this item on the
Consent Agenda at the May 18, 2014 Regular Meeting.
Attachment: RCO Amendment to Project Agreement
W,\PW Eng\PROJECTS\A. DR Projects\Duwamish Gardens 06-DR02 (90630102)\GrantskConstruction\PSAR\AddftionaI Funding Requestkinfo Memo RCO Construction Grant Amendment gI-sb.docx
WASHINCTON STATE
Recreation and
Conservation Office Amendment to Project Agreement
Project Sponsor: City of Tukwila Project Number: 13-1099R
Project Title: Duwamish Gardens Restoration Amendment Number: 1
Amendment Type:
Cost Change
Amendment Description:
The project agreement amount is increased by $1701,335,47 of 2013-15 PSAR, $79,664.53 of 2011-13 PEAR and
$80,000 sponsor match to afford cost increases primarily associated with the Section 106 Consultation and
mitigation of impacts to historic and pre-historic cultural resources as outlined in the MOA (PRISM Attach, No.
#215119).
Project Funding:
The total cost of the project for the purpose of this Agreement changes as follows:
RCO - PEAR
RCO - SALMON ST PROJ
Project Sponsor
Total Project Cost
Admin Limit
A&E Limit
Agreement Terms
701FUTUTSM,
Amount %
$622,081 00 49.73%
$327,353,00 26,17%
$301,523,00 24.10%
$1,250,957.,00 100%
$0.00 Oi.00%
$11 0,00U0 9i.64%
New Amount
Amount
$872,081,00
55.16
$327,35100
20.71
$381,523.00
24.13
$11,580,95700
100
$0.00
0.00
$139,004.25
9.6401
In all other respects the Agreement, to which this is an Amendment, and attachments thereto, shall
remain in full force and effect. In witness whereof the parties hereto have executed this Amendment.
State Of Washington
Recreation and Conservation Office
BY: dw kL
Kaleen Cotfinqham L)
City of Tukwila
AGENCY:..d
1_4
BY:
TITLE: y'"
J
it
6 aLfAt_5-
PSAR Project Cost Change Amendment
Salmon Fundina Accounts Chapter 77.85 RCK Chanter 420 WAC 2
AMENAGMAPT
Project onsoir: City of Tukwila
Project Title: Duwarnish Gardens, Restoration
mm� MM
AAGREEDSC .PP T March 2, 2015 Page 1
Amendment Special Conditions
Project Sponsor. It of Tukwila Project Number: 13-1:1099 R
Project Title: Duwamish, Gardens Restoration Amendment Number: I
ff,
ASPECCONURPT March 5, 2015 Page 1
5MMIMaRrin
I I � I III � I
I F
I
Any signiage or press materials must acknowledge the Puget Sound Acquisition and Restoration Fund as well as RCO
as a fund source.
ASPECCOND,RPT March 5, 2015 Page 3
Project Sponsor: City of Tukwila
Project Title: Duwamisih Gardens Restoration
Program: Puget Sound Acq. & Restoration
Restoration M�etrics
VITM M H 0 C U Log = II &T% Ws M Ms
Targeted salmonid ESEW&
Targeted species (non-ESU species):
...........................
MEMO=
Restoration fencing and g,ates
Number of g!ates:
Linear feet of fencing:
Traffic controil
Utility relocation / reconnection
Utilities relocated / reconnecte&
EMEME=
t I 'I It I I
2=617041WIM
WWI
IOE
a
been completed monitoring and data
recovery during construction, and
mitigation whichi are eligible
pre-agreement expenses, not included
in scope of design grant,
the Design contract,
6
AELIGRENAPT March 2, 2015 Page:
"NE47raTim-
L Agency Name
Recreation and Conservation Office
P.0, Box 40917
9850,4-0917
Sponsor
Tukwila City of
Public Works Dept
6300 Southcenter Blvd Ste 100
TukMa, WA 98188
FORM A-119 State of Washington
INVOICE VOUCHER
and totals fisted herein are proper charges for materials, merchandise or
services furnished to the State of Washington, and that all goods furnished
of ag or, national ongin, handicap',
religion or Vietnam era or disabled veterans status.
M
RIUM
Em
Pr*ct Number 13-1099 R
Billinig Period
Project Name Duwarnish Gardens Restoration
Fmm,
TO,
i sE endiftitesJoi Date
Costs For,This Billing
Pro
Reimbursable
CATEGORI
FUNDING & EXPENDITURE FORMULA
Fair RCO Use ONLY
Agreement Informabion
— - ------- -
Previous RC,0 Reimbursements
19FUMMAR
0 Fade al.
RCO: SALMON ST a R O
1» w
1'
Share Approved
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .....
Agreement Tot
01 #1100
Match Bank
urren
ertifidation,
For pa�rnent
i ipjNinirr- PPT 31212015
City of Tukwila
Jim Haggetton, Mayor
TO: Mayor Haggerton
Community Affairs and Parks Committee
Utilities Committee A
FROM: Bob Giberson, Public Works Director /fZ��
By: Ryan Larson, Senior Program Manager
DATE: May 8, 2015
SUBJECT: Duwamish Gardens
Project No. 90630102
Bid Award
ISSUE
Award the bid for construction of the Duwamish Gardens project.
BACKGROUND
The City acquired the Duwamish Gardens site in 2008 for future restoration as a salmon
habitat site with minor park elements. The project's design and permitting are complete.
ANALYSIS
The Duwamish Gardens project was advertised for bids on March 17 and 24, 2015. Eight bids
were received and opened on April 15, 2015. The bids were checked, corrected, and
tabulated. McCann Construction Enterprises, Inc. is the apparent low bidder with a bid of
$2,447,346.95. The Engineer's Estimate was $2,345,993.94. References were checked and
McCann Construction has successfully constructed other municipal projects.
The overall bid is more than the Engineers Estimate and more than the current budget listed
in the 2015 CIP. A complete budget review was performed on the Duwamish Gardens Project
including acquisition, design, and estimated construction costs. It was determined that a total
of $54,213 in construction budget was required to complete the acquisition and design of the
project. This additional funding includes added acquisition and design costs associated with
the expanded site and additional design costs related to the required cultural resources work.
For additional grant funding, staff worked with WRIA 9 and determined that approximately
$200,000 in additional King Conservation District (KCD) funding is available from the recently
completed Seahurst Park Project in Burien. WRIA 9 and KCD staff are both supportive of
these available funds being transferred to Tukwila pending approval of the WRIA 9 Forum and
KCD Board. Given the high priority both entities have placed on the Duwamish Gardens
Project, approval of this additional funding is expected.
Staff also reviewed the 2015 CIP to determine where additional funding could be transferred
from a different CIP project. Habitat projects are now included under the 412 Surface Water
Utility due to surface water runoff's impact on receiving water bodies. It was determined that
the East Marginal Way S Stormwater Outfalls Project has funding that could be used now for
Duwamish Gardens as the Outfalls construction will be delayed until 2016. In addition, the
East Marginal Way S Stormwater Outfalls Project had anticipated grant funding of $300,000 in
"I, PRAVI
Page 2
2017, but staff applied for funding through Washington State's Department of Ecology (DOE)
and has been notified that the project has been tentatively approved to receive $1,106,000 in
project funding. This DOE grant requires a 25% sponsor match and can be used for
completion of project design, construction management, and construction. Of the $732,000 in
current surface water utility funding proposed through 2017, $456,000 can be used for other
projects and still leave $276,000 in available matching funds. It is recommended a portion of
these funds be used to cover the budget shortfall in the Duwamish Gardens project.
BUDGET AND BID SUMMARY (All amounts include sales tax.)
Bid Results Encl. Estimate Bud-get
Bid Amount $2,447,346.95 $2,345,993.94 $2,125,000.00
Construction Budget Needed for Design (54,213.00)
Grant Amendment - RCO 250,000.00
Additional KCD Funding - Proposed 200,000.00
East Marginal Wy S Stormwater Outfalls 171,295.00
Contingency (10%) 244,734.70 234,599.39 0.00
Total $2,692,081.65 $2,580,593.33 $2,692,082.00
RECOMMENDATION
Council is being asked to award the construction of the Duwamish Gardens project to McCann
Construction Enterprises Inc. in the amount of $2,447,346.95 and consider this item at the
May 18, 2015 Regular Meeting.
Attachment: Pages 36 and 88, 2015 CIP
Bid Tabulation
10
WAPW Eng\PROJECTS\A- DR Projects0uwarnish Gardens 06-DR02 (90630102)\DesignWO MEMO Contruction Award gl-sb.docx
CITY OF TUKWILA CAPITAL PROJECT SUMMARY
2015 to 2020
PROJECT: Duwamish Gardens Project No. 90630102
DESCRIPTION: Purchase and restore site as a salmon estuary and passive park.
JUSTIFICATION: This project is included in the WRIA 9 Salmon Recovery Plan's efforts to acquire and restore 20-acres
within the Duwamish estuary. Also includes all riverfront property from E Marginal VVy S to Tukwila Int'l Blvd.
STATUS: Property acquired in 2008. Design began in 2012 with construction scheduled to begin in 2014.
MAINT. IMPACT: With a new passive park, additional maintenance will be needed.
Funding from State Salmon Recovery Board (SRFB), King Conservation District (KCD), WRIA 9 King
COMMENT: Conservation District, King County Conservation Futures, WA State Aquatic Lands, WA State Earmark,
King County Flood Control District, and Puget Sound Acquisition and Restoration (PSAR) grants.
FINANCIAL Through Estimated
(in S000's► 2013 2014 2015 2016 2017 2018 2019 2020 BEYOND TOTAL
EXPENSES
Design
403
90
493
Land (RNA
2,134
60
2,194
Const. Mgmt.
50
265
315
Construction
7
750
1,375
2,132
TOTAL EXPENSES
2,544
1 950
1 1,640
1 01
01
01
01
01
01
6,134
FUND SOURCES
Awarded Grant Land
2,011
2,011
Award Grant Design
270
131
401
Award Grant Const.
750
1,614
2,364
Mitigation Expected
0
City Oper. Revenue
263
69
26
0
0
0
0
0
0
358
TOTAL SOURCES 1
2,5441
950
1 1,640
1 01
01
01
01
01
01
5,134
2015 - 2020 Capital Improvement Program 36 11
CITY OF TUKWILA CAPITAL PROJECT SUMMARY
2015 to 2020
PROJECT: East Marginal Wy S Stormwater Outfalls Project No. 91041204
DESCRIPTION: Establish legal drainage connections from East Marginal Way South to the Duwamish River.
JUSTIFICATION: Drainage from E Marginal Wy S is discharged through outfalls owned and operated by the Boeing Co.,
Jorgensen Forge, and two King County Airport storm systems without easements.
Jorgensen Forge outfall was closed in 2011 under an order from the US EPA. The Boeing Company
STATUS: contacted the City in 2009 requesting that the City take over ownership of their storm line and outfall. A
consultant is preparing design for rerouting the Jorgensen outfall and adding water quality features.
MAINT. IMPACT: Clarifies maintenance responsibility and will ensure reliability of system.
City Attorney is working on the easements for Jorgensen's and Boeing's outfalls. Phase I: Adopt Boeing's
COMMENT: Z Line and then line lower portion of pipe in 2014. Phase 11: Line pipe, add water quality device and connect
Jorgenson's drainage to Boeing's Z Line in 2015 and 2016. DOE design grant proposed in 2014.
FINANCIAL Through Estimated
(in $000's) 2013 2014 2015 2016 2017 2018 2019 2020 BEYOND TOTAL
EXPENSES
Design
59
140
10
50
259
Land (R/W)
0
Const. Mgmt.
10
30
91
131
Construction
100
191
550
841
TOTAL EXPENSES
1 59
1 1401
120
1 271
1 641
1 01
01
01
01
1,231
FUND SOURCES
Awarded Grant
120
120
Awarded Grant
20
20
Proposed Grant
300
300
Mitigation Expected
0
Utility Revenue
59
0
120
271
341
0
0
0
0
791
TOTAL SOURCES 1
59
1 11401
1201
271
1 641
1 01
01
01
01
1,231
2015 - 2020 Capital improvement Program 88 12
CITY OF TUKWILA
DEPARTMENT OF PUBLIC WORKS
Duwamish Gardens
Bid Tabulation
Project No. 90630102
Date:
Item
15- Apr -15
Description
Quantity
Unit
Engineers Estimate
Unit Price Amount
McCann Construction
Unit Price Amount
MidMountain Contract. Inc.
Unit Price Amount
Pivetta Brothers Const. Inc.
Unit Price Amount
ERRG
Unit Price
Amount
Ohno Construction Company
Unit Price Amount
Olson Brun. Excavating
Unit Price Amount
3 Kings Environmental Inc.
Unit Price Amount
A -1 Landscaping and Const.
Unit Price Amount
ROADWAY
1
Mobilization
LS
17175197
17175197
20140100
20140100
230,000.00
230,000.00
139,297.00
139,297.00
10710100
107,50100
25100100
259,00100
20100100
20100100
338,000.00
338,000.00
26100100
26100100
2
Contractor Supplied Surveying and Staking
LS
1020100
1020100
1100100
1100100
1100100
1100100
137100
137100
2100100
21000.00
20,00100
2100100
2100100
2100100
2100100
2100100
1100100
11000.00
3
Permits and Licenses
LS
150100
150100
150100
250100
150100
150100
11,680.00
11,680.00
4,00100
4,00100
100100
100100
1100100
1100100
5,000.00
100100
1100100
1100100
4
Resolution of Utility Conflicts
FA
2100100
2100100
2100100
2010100
2100100
2100100
2100100
2100100
2100100
2100100
2010100
2100100
2100100
2100100
2100100
2100100
2100100
2100100
5
Project Temporary Traffic Control
LS
220100
220100
31000.00
3910100
750100
750100
2144100
2144100
3000100
3000100
10,00100
1100100
5100100
5100100
1100100
1100100
1100100
11000.00
6
Clearing and Grubbing
LS
180100
180100
2170100
2270100
2100100
2100100
11904.00
11904.00
2100100
2100100
4100100
4100100
100100
100100
30,000.00
3100100
3150100
3150100
7
Pavement Removal Including Haul (AC-)gravel)
1552
SY
564
11311.49
1.00
1,55210
100
7,76100
1.00
1,55210
715
1133140
100
9,31200
1210
11624.00
100
9,31200
1800
27,93100
8
Cement Concrete Sidewalk Removal Inc. Haul
21
SY
1180
41180
14.00
294.00
5100
115100
4.00
84.00
3125
63525
1100
27100
14.00
294.00
100
18100
3500
73100
9
Cement Concrete Curb Removal Inc. Haul
77
LF
164
434.51
100
61100
100
385.00
100
462.00
1125
86125
100
61100
7.00
53100
10.00
77100
7.00
53100
10
Removal of Structure and Obstructions- Parking Area
LS
2,20100
120100
110100
110100
50100
50100
125800
125800
110100
110100
710100
710100
12,000.00
12,000.00
2110100
2110100
3100100
3100100
11
Removal of Structure and Obstructions- Structure A
LS
2210100
2210100
4000100
4310100
3100100
3100100
2153100
2153100
4100100
4100100
2450100
2450100
2100100
2100100
3125100
3125100
7710100
7710100
12
Removal of Structure and Obstructions - Structure B (Farmhouse)
LS
2210100
2210100
4110100
4110100
2150100
2150100
1146100
1146100
3110100
3110100
1150100
1150100
2100100
2100100
2125100
2125100
5100100
5100100
13
Salvage Materials- Structure B (Farmhouse)
FA
150100
150100
100100
510100
100100
100100
100100
100100
100100
100100
510100
510100
100100
100100
100100
100100
100100
100100
14
Removal of Structure and Obstructions- Structure C
LS
150100
150100
210100
210100
000100
000100
1751100
17,51500
100100
100100
210100
210100
2100100
2100100
210100
100100
2210100
2210100
15
Removal of Structure and Obstructions - Structure D
LS
1110100
1110100
1150100
1250100
100100
100100
1751100
17,515.00
100100
100100
520100
520100
2100100
2100100
1100100
1100100
3100100
3100100
16
Removal of Structure and Obstructions- Structure E
LS
2210100
2210100
2100100
2010100
1150100
1150100
9,21800
9,21800
1100100
1100100
1910100
19,00100
2100100
2100100
1150100
1150100
6110100
6110100
17
Removal of Structure and Obstructions- Structure F
LS
030100
030100
110100
110100
150100
150100
7,13500
7,13500
110100
110100
70100
70100
1100100
1100100
210100
100100
1100100
1100100
18
Removal of Structure and Obstructions - Structure G (Barn)
LS
2210100
2210100
3100100
3810100
14,00100
14,00100
47114.00
47114.00
2710100
2710100
1210100
1180100
2100100
2100100
1100100
1100100
2180100
2180100
19
Salvage Materials- Structure G (Barn)
LS
1198100
1198100
100100
510100
710100
710100
1411100
14,01100
1310100
13,00100
310100
310100
1100100
1100100
310100
3,00100
35,40100
35,40100
20
Removal of Structure and Obstructions - Structure H
LS
030100
030100
110100
110100
60100
60100
11671.00
11671.00
40100
40100
90100
90100
100100
100100
000100
000100
1100100
1100100
21
Removal of Structure and Obstructions - Structure I
LS
030100
030100
150100
150100
150100
150100
176100
176100
46100
46100
1,90100
1,90100
150100
150100
000100
000100
2110100
2110100
22
Removal of Structure and Obstructions- Underground Tank(s)
2 EA
1110100
2210100
1100100
2010100
100100
1100100
14,74100
2149100
3,850.00
7,70100
110100
620100
100100
1100100
100100
100100
1210100
24,00100
23
Demolish Chain Link Fence
547
LF
178
3,15193
100
3,28200
5.00
2,735.00
9.00
4,92300
4.00
118800
4.00
2,18800
5.00
2,735.00
5.00
2,735.00
5.00
2,735.00
24
Water Main Abandon and Repair Work
1 LS
030100
030100
150100
150100
1100100
1100100
7,92100
7,92100
210100
100100
510100
510100
100100
100100
1100100
1100100
12,40100
12,400.00
25
Excavation, Handling and Disposal of Contaminated Soil
2012
TON
53.90
10144610
55.00
110,660.00
60.00
12172100
9100
197,176.00
5100
111696.00
82.00
164,984.00
9100
181,080.00
80.00
16196100
135.00
271,620.00
26
Excavation (including Class II)
22805
CY
11.00
25185100
100
13183100
100
11412100
310
7181710
150
12142710
135
144,81115
710
159,63100
100
20124100
2210
50111100
27
Cultural Resource Site Excavation
4599
CY
3130
16594170
210
9,19100
710
3119100
100
41,39110
4.10
1185190
11.40
52,428.60
2100
91,98100
1210
5118100
3100
174,76210
28
Embankment fill and compaction
965
CY
180
149100
100
4,825.00
7.00
1755.00
100
7,72100
120
7,913.00
190
158150
23.00
21195.00
14.00
13510.00
11.00
11615.00
29
Excess Common Excavation (including Class II) Haul and Dispo:
29294
CY
13.20
38168180
2100
73135100
3100
87182100
2210
644,46800
3300
96170200
26.73
78312162
2100
849,52100
2100
76114400
3800
1,113,17210
30
Gravel Borrow
8 CY
7150
57210
5100
40100
3100
24100
4100
344.00
41.00
32100
9100
76100
16100
1104.00
6100
48100
2100
224.00
31
Temporary Dewatering
1 LS
2750100
2750100
34,00100
3410100
11100100
11100100
131503.00
131503.00
26100100
26100100
9010100
9100100
15100100
15100100
33100100
33100100
8100100
8100100
32
Temporary Shoring and Cofferdam
1 LS
2710100
2710100
710100
710100
7100100
7100100
4154100
4154100
2100100
2100100
2210100
2150100
4100100
4100100
5100100
5100100
6100100
6100100
33
Construction Geotextilo for Soil Stabilization
729
SY
220
110180
710
110100
4.00
1916.00
1.00
72100
150
592550
100
2,18710
500
064100
100
118710
710
110100
34
Construction Geotextilo for Ditch Lining
240
SF
220
52100
710
118100
1.75
42100
210
48100
225
54100
2.10
504.00
710
118100
100
72100
100
116100
ROADSIDE DEVELOPMENT
35
4" Streambed Cobbles (for spillway)
8.5
TON
60.50
514.25
19100
1115.00
25100
1125.00
103.00
87150
5100
47100
285.00
242150
123.00
114150
75.00
637.50
65.00
55150
36
Crushed Surfacing Top Course
50
TON
3180
1,54100
11100
150100
4100
2,25100
2710
1,35100
3175
1,83710
7710
315100
6100
100100
5100
175100
3100
115100
37
Crushed Surfacing Base Course
80
TON
2190
117210
10100
810100
3150
192100
2710
116100
3575
186100
6100
5,44100
6100
4,80100
5500
4,40100
2100
224100
38
HMA Class 1/2" Pavement, In Place
50
TON
110.00
5,500.00
200.00
10,000.00
125.00
6,250.00
308.00
1140100
222.00
11,100.00
150.00
7,500.00
150.00
7,500.00
275.00
1175100
135.00
6,750.00
39
Cement Concrete Pavement (for Gathering Plaza)
1411
SF
2710
3180210
1715
24,339.75
1100
1134100
3210
4115200
11.75
11579.25
2215
32,10125
21.00
29,63110
2100
2122100
800
11,28800
40
Cement Concrete Commercial Driveway
30
SY
82.50
147100
10100
310100
8100
2,40100
184.00
152100
12100
075100
13710
4,11100
15100
4,50100
18100
140100
9500
185100
41
FocaI Point Sculpture (budget)
1 LS
36,30100
3130100
27,00100
2710100
25,00100
2100100
36,13710
3113710
30,00100
3100100
30,00100
3100100
35,00100
3100100
30,00100
3100100
70,87100
7187100
42
Freestanding Sign and Frames (including Interpretive signs)
2 EA
4,620.00
9,240.00
120100
140100
210100
4,00100
136100
4,736.00
1,925.00
3,850.00
3,40100
6,80100
2,00100
4,00100
4,00100
100100
5,50100
11,00100
43
Metal inlays Into Paved Surfaces
1 LS
180100
180100
2100100
2610100
1150100
1150100
27149.00
27,049.00
2210100
2100100
27,00100
27,00100
16,00100
16,00100
27,50100
27,50100
8,80100
8,80100
44
Pine Rail fence
1305
LF
1150
21,532.50
1210
1166100
1210
1166100
1710
22,18100
14.00
1127100
12.50
11312.50
1100
1957100
2100
2110100
1100
1196100
45
City of Tukwila Park Sign
1 EA
3,850.00
3,850.00
220100
220100
750100
750100
1,824.00
1,824.00
145100
145100
210100
210100
2100100
2100100
1100100
1100100
1120100
1120100
46
Park Sign
1 EA
1110100
11,00100
1120100
16,20100
110100
110100
113100
113100
1,10100
1,10100
17,75100
17,75100
2410100
2410100
1100100
1100100
710100
710100
47
Paint Line
60
LF
220
132.00
1100
96100
100
30100
20.00
1,20100
7.50
45100
100
36100
12.00
72100
20.00
1,20100
3.00
18100
48
Permanent Ground Anchors
77
EA
55100
4135100
30100
23,10100
8500
154100
90100
69,30100
29100
2171100
27710
2112100
65100
5105100
50100
3150100
55100
4135100
49
Erosion Control and Water Pollution Control
1 LS
5100100
5100100
7100100
7510100
2100100
2100100
21048.00
21048.00
4110100
4110100
10199100
10199100
3100100
30,000.00
140,000.00
140,000.00
110,000.00
110,000.00
50
Seeding, Fertilizing and Mulching (Erosion Control Mix)
122
ACRE
150100
1,21100
130100
1,16100
2,20100
484.00
137800
1,84116
4,20100
924.00
219100
52180
100100
112100
120100
1,14400
710100
1,71100
51
Seeding, Fertilizing and Mulching (High Marsh Seed Mix)
134
ACRE
22,00100
7,48100
12,50100
4,25100
2,50100
85100
19,90710
176138
3,86100
1,312.40
2,68100
91120
11,50100
311100
13,00100
4,42100
8,00100
172100
52
Seeding, Fertilizing and Mulching (Low Marsh Seed Mix)
124
ACRE
22,000.00
5,280.00
17,000.00
4,080.00
120100
528.00
2614100
6,46132
4,20100
1,008.00
2,440.00
585.60
1100100
160100
17,000.00
4,080.00
180100
1,87100
53
Coir Log (Bio-D Blocks)
177
LF
1550
2,92150
21.25
3,761.25
3100
184100
13100
2189100
3100
119100
3100
131100
7100
1127100
8100
1104100
100
116200
54
Topsoil Type
394
CY
4150
19,50100
3125
1131250
4500
17,73100
5100
19,70100
34.00
1319610
51.00
21094.00
3100
1112100
3500
1319100
4100
1191210
55
Loosen Topsoil - rip tol8 " (el 8 and below)
774
BCY
1215
1791.10
100
4144.00
100
317100
4.00
3196.00
2.10
112140
100
4144.00
100
087100
100
087100
2210
1712100
56
Compost (3" across whole site)
557
CY
4150
2757110
34.50
1121150
50.00
2715100
55.00
31635.00
2710
1131710
5100
3163100
3100
1149100
3100
1149100
5100
3163100
57
Bark or Wood Chip Mulch (3" in non -marsh planted areas)
553
CY
4150
2717150
37.25
21599.25
4710
2199100
59.00
3162700
2125
11857.25
5100
29,309.00
34.00
11802.00
3100
19,35100
5100
3141100
58
Seeded Lawn Installation
422
SY
150
132110
1.40
59180
155
232.10
210
844.00
150
1,47710
161
257.42
125
527.50
210
844.00
4.00
118100
59
PSIPE-Livestake Plantings
577
EA
1.10
634.70
2.00
1,154.00
2.45
1,41165
3.00
1,731.00
4.10
136170
165
152105
1.75
110175
2.00
1,154.00
100
1462.00
60
PSIPE- 12 " -18" Bare root plantings
475
EA
2.20
114500
100
1,42500
110
99710
100
137100
4.00
1,90100
235
1,11125
100
1,42100
100
1,42100
100
2,85100
61
PSIPE - 18" Bare root plantings
1,153
EA
220
253160
125
074725
225
2594.25
100
176100
125
074725
2.55
214115
100
3,45100
4.00
4,61210
100
191000
62
PSIPE 4" Pot Container Plants
330
EA
160
2,178.00
4.00
1,32100
4.00
1,320.00
6.00
1,980.00
7.00
2,310.00
4.50
1,485.00
4.00
1,320.00
4.00
1,320.00
6.00
1,980.00
63
PSIPE -10" Tube Container Plants
5171
EA
2.20
1157520
150
2119150
175
2114115
100
3185100
4.25
2122175
4.10
25,301.10
100
18,51100
4.00
24,684.00
800
49,36800
64
PSIPE - 1 Gallon Container Plants
2753
EA
11.00
3028100
150
17194.50
175
1182175
1100
27,53100
160
1116180
140
1711120
100
1151100
710
11271.00
1100
41554.00
65
PSIPE- 2 Gallon Container Plants
41
EA
1150
67150
17.00
697.00
22.00
902.00
27.00
1,107.00
44.00
1,804.00
24.50
1104.50
1100
61100
17.00
697.00
24.00
984.00
66
PSIPE- 5 Gallon Container Plants
193
EA
5210
10,19140
22.25
4,294.25
3100
179100
3100
6,75100
3710
7,14110
3150
6,46150
21.00
4,05100
2710
5,21110
3210
6,17100
67
PSIPE -11/2 "Caliper Plants
9 EA
16100
1,48100
24100
2,16100
9100
85100
37210
314810
19100
1,75100
104.00
93100
21100
113100
30100
170100
25100
225100
68
Removal of Buried Man -made Debris
1 FA
2210100
2210100
2100100
2010100
2100100
2100100
2100100
2100100
2100100
2100100
2010100
2100100
2100100
2100100
2100100
2100100
2100100
2100100
69
Irrigation Water System
1 LS
82197.13
81097.13
3750100
3710100
3100100
3100100
5150100
59,50100
4100100
4100100
37,10100
37,10100
4100100
4100100
4100100
4100100
4100100
4100100
70
Cement Concrete Traffic Curb
230
LF
1120
3136.00
3100
190100
3100
128100
4100
11,040.00
52.50
1107100
3150
819100
2100
175100
3100
105100
2210
106100
71
Cement Concrete Traffic Curb &Gutter
15
LF
1320
198.00
30.00
450.00
36.00
540.00
11100
1,74100
104.00
1,560.00
100.00
1,500.00
60.00
900.00
35.00
525.00
35.00
525.00
72
Chain Link fence
815
LF
3120
2168800
24.00
19,56100
3210
2108100
3100
2152100
3125
2172175
2140
2170100
31.00
2126100
3100
24,45100
3210
2108100
73
Permanent Signing
1 LS
22100
22100
25100
25100
50100
50100
1517.00
1,51710
150100
1,50100
1,15100
1,15100
100100
100100
150100
150100
4100100
4100100
74
Painted Access Parking Space Symbol
1 EA
9100
99.00
32100
32100
50100
50100
363.00
36100
620.00
620.00
580.00
580.00
250100
150100
25100
25100
45100
45100
75
Rock Wall
132
FF
13210
17,424.00
44100
5818100
6100
712100
59100
7127100
33100
51,48100
37100
4150100
40100
5180100
16100
21,12100
3100
101100
CITY OF TUKWILA
DEPARTMENT OF PUBLIC WORKS
Duwamish Gardens
Bid Tabulation
Project No. 90630102
Date:
15- Apr -15
Engineers Estimate
McCann Construction
MidMountain Contract. Inc.
Pivetta Brothers Const. Inc.
ERRG
Ohno Construction Company
Olson Bros. Excavating
3 Kings Environmental Inc.
A -1 Landscaping and Const.
76
Seat Boulder
5
EA
4,730.00 23,650.00
4,300.00 2190200
4900.00 20,000.00
4,570.00
2285200
325200 1825200
4,500.00
22,500.00
4,500.00
2290200
280020
1900200
4,500.00
2290200
77
Boulder-Mounted Bench - Accessible
1
EA
4,40200 4,400.00
4,72200 4,725.00
2,90200 290200
5,52900
592900
5,10200 210200
4,60200
4,600.00
250200
690200
2,50200
250200
3,80020
280200
78
Bike rack
1
EA
1,10200 1,10020
1,22200 122900
1,150.00 1,150.00
95820
95820
1,02200 122900
1,750.00
125200
200200
200020
1,50200
190020
220200
220020
79
Trash receptacles
1
EA
99020 990.00
145200 1,45200
95200 95200
1,58420
1,584.00
1,10020 1,10200
220020
220200
250020
290200
1,50020
1,50200
250200
290200
80
Type 1 Removable Bollard
2
EA
124520 209200
72520 1,45200
190020 200200
95820
1,91620
55200 1,10200
45200
90200
200020
420200
80020
120200
98200
126200
81
Habitat Logs w/ Root Wads
24
EA
220200 5280200
1,40200 3320200
1,10200 2240200
947.00
2272820
1,22200 2240200
190200
3200200
200200
12200200
271200
65,160.00
280200
6220200
82
Stumps with Root Wads
5
EA
1,92900 262900
95200 4,750.00
70020 390020
34720
1,73900
1,15200 975200
83200
4,15200
900020
2900020
216900
1092900
390020
1250020
83
Habitat Log
12
EA
1,925.00 2210200
90200 1980200
90200 1280200
51320
6,156.00
1,11200 1232200
94200
1128200
200200
6200200
2,44200
2928200
220200
26,400.00
84
Habitat Snag
5
EA
1,430.00 7,15200
1,250.00 6,250.00
120200 200200
947.00
4,735.00
122200 262200
120200
250200
720200
3200200
205200
1027200
220200
1200200
85
Stone Pavers (Flagstone Paving - Gathering area)
149
SF
44.00 695620
5320 7297.00
3200 521200
4200
620200
4620 625420
60.00
294200
27200
4297200
140.00
20,860.00
4200
620200
86
6" Streambed Cobbles (for cobbles/cobble spit)
23
TON
6620 1,51820
10020 230020
8900 1,95900
22120
908320
6620 1,51820
16220
322900
8200
124200
8200
1,84200
13900
210900
87
Streambed Boulders (1/2 Men -3 Man)
65
TON
16200 1272200
10200 622200
14200 910200
22120
14,36200
10220 6,63200
18220
11,83200
14200
942200
16200
1240200
15200
1207200
88
Drain Rock
52
TON
44.00 228820
57.00 2964.00
7200 290200
27.00
1,404.00
4250 252200
7820
4,056.00
6200
3,380.00
7200
290200
4200
234200
89
Goose Excluder
1
LS
4,400.00 4,400.00
2020020 2020020
2090020 2090020
4028920
4028920
2020020 2020020
5890020
5890020
1890020
1890020
2020020
2020020
4900020
4900020
90
Kiosk
1
EA
1220200 1220200
1200200 1200200
10,10200 10,10200
258820
258820
1250200 1250200
9,50200
950200
1200200
1200200
20,00200
2200200
1200200
1200200
91
Scrambling Path -3' wide (lump sum)
1
LS
205200 6,050.00
200200 200200
200200 200200
2304.00
2304.00
1,55200 1,55200
6,50200
6,500.00
2200200
2200200
1200200
1200200
2987200
2987200
92
Fire Pit
1
LS
60200 60200
67200 67200
250200 250200
293620
293620
525200 525200
200200
200200
620200
620200
1,50200
1,50200
250200
250200
93
Crushed Surfacing
5177
SF
195 254225
290 1224290
1.50 7,76950
1.00
2177.00
1.85 9577.45
1.70
280290
295
1124895
1.50
7,76950
620
3126220
STORM DRAINAGE
-
94
Slotted Underdrain Pipe -6" PVC
35
LF
1950 57790
3900 126200
4200 1,40020
3720
129900
2920 1,01900
4220
147200
64.00
224200
2900
87900
6200
210020
95
Corrugated Polyethylene Storm Sewer Pipe 12" Dia.
46
LF
7190 228900
5390 2,46120
66.00 2036.00
6900
299200
7790 254220
44.00
2224.00
8320
281820
4900
207200
9900
4,14900
96
Corrugated Polyethylene Storm Sewer Pipe 8" Dia.
220
LF
6620 14,52200
3725 8,19200
17.00 274200
5200
11,440.00
3250 8,030.00
40.00
820200
7320
16,060.00
3200
7,70200
7200
1690200
97
Solid Catch Basin Lid
1
EA
22200 22200
40200 40200
35200 35200
33900
33900
125200 125200
45200
45200
65200
65200
75200
75200
20200
20200
98
Beehive Grate
1
EA
60200 60200
40200 40200
35200 35200
336.00
336.00
90200 90200
2,80200
280200
190200
190200
75200
75200
45200
45200
99
Type Catch Basin
1
EA
1,37200 1,37200
1,150.00 1,150.00
1,650.00 1,650.00
1287.00
1287.00
231200 231200
89200
89200
1,30200
1,30200
1,250.00
1,250.00
2,100.00
210200
100
Connection to Existing Drainage Structure
2
EA
44200 88200
72900 145200
82900 125200
374.00
74820
67200 1,34200
1,10200
220200
210200
220200
250200
900200
45200
90200
101
Gravel Backfill for Drain
5
CY
2790 13790
10200 50200
7900 37200
2790
13200
5900 25200
13200
65200
15190
75200
16200
80200
4900
22200
102
Sewer Cleanout
2
EA
27200 55200
50200 1,00200
150.00 30200
36820
73620
630.00 1,260.00
650.00
1,30200
200200
4,00200
35200
70200
120200
240200
103
Bio-retention Soil Mixture
30
CY
1950 49900
9200 270200
3320 99200
7220
216200
8820 264200
9220
276200
7120
213200
6900
1,95200
6900
1,95200
104
Curb Scupper
2
EA
11900 22200
5900 11200
20200 40200
10200
21200
125200 270200
50200
120200
190200
200200
75200
1,50900
65200
1,30200
SUBTOTAL
214246222
293902905
222242820
2454,98286
295233290
296293329
2997,16220
2077,96200
4,119,40950
SALES TAX (0.095)
20253972
212,326.90
220,630.66
233,223.66
242,566.62
243,288.67
284,730.39
292,406.68
391,343.90
TOTAL
$2,345,993.94
$2,447,346.95
$2,543,058.66
$2,688,209.52
$2,795,899.42
$2,804,222.06
$3,281,892.39
$3,370,371.68
$4,510,753.40
Bold = Error
Rounding Error
City of Tukwila
Jim Haggerton, Mayor
TO: Mayor Haggerton
Utilities Committee
FROM: Bob Giberson, Public Works Director440
BY: Mike Cusick, PE, Senior Program Manager
DATE: May 8, 2015
SUBJECT: CBQ Sanitary Sewer Rehabilitation/APW to APE Sewer Repair
Project No. 91140203, Contract No. 14-159
Change Order No. 3
ISSUE
Approve Change Order No. 3 with the R.L. Alia Company (Alia) for the APW to APE Sewer Repair Project in the amount of
$91,152.15, including sales tax.
BACKGROUND
A contract with Alia was awarded by Council on September 15, 2014 for work that included the repair of a collapsed sewer line
between APW and APE and also the installation of a manhole in Andover Park East near Strander Blvd. The Notice to
Proceed was given to the contractor on October 15, 2014 and the contractor started work on the project on December 5,
2014.
DISCUSSION
Alia was able to complete the repair of the collapsed sewer line between APW and APE in accordance with the original
construction contract. The APW sewer repair was intended to enable the entire line between APW and APE to be sliplined as
part of a second, separate contract with the Michels Corporation. During the necessary effort to clean and video the sewer line
for sliplining, a second (new) collapsed portion of the sewer line was discovered. This newly collapsed portion of the sewer
line needed to be repaired before the sliplining work could take place. Alia was then requested to repair the second collapsed
sewer line in order to allow the sliplining work to proceed.
The scope of work to repair the second sewer main collapse (Change Order No. 3) could not be estimated at the time as the
extent of the collapsed pipe was not known. Alia was asked to expose the new collapsed pipe to determine the extent of the
damage under an agreement to pay them for their time and materials. The contractor was able to expose the pipe and repair it
without any additional design effort or any need to evaluate alternatives. The entire sewer line between APW and APE was
successfully sliplined without incident by Michels after all repairs had been completed.
FISCAL IMPACT
Change Order No. 3 covers the cost for Alia to perform the repair of the second, unanticipated collapsed sewer line. Tracking
of their actual costs to perform this additional work amounted to $91,152.15, including sales tax. Since two separate contracts
were awarded as part of the same CIP project, the total contingency for the CBD Sewer Rehabilitation Project is considered.
Contract
Contract Alia $342,560.90
Contract Michels 238,270.91
Totals $580,831.81
Contingency Additional Funds Needed
$81,245.27 $44,263.41
32,118.97 0.00
$113,364.24 $44,263.41
IN
INFORMATIONAL MEMO
Page 2
After Change Order Nos. 1 and 2 and contract overruns were accounted for, there is $46,888.74 remaining in the contingency.
To cover the full amount of Change Order No. 3 at $91,152.15, the additional $44,263.41 required to complete the APW to
APE Sewer Repair Project will be funded from the 2015 construction funds of the CBD Sewer Rehabilitation Project.
RECOMMENDATION
Council is being asked to approve Change Order No. 3 to Contract No. 14 -159 with the R.L. Alia Company in the amount of
$91,152.15 for the APW to APE Sewer Repair Project and consider this item on the Consent Agenda at the May 18, 2015
Regular Meeting.
Attachments: Spreadsheet of Costs
Page 71, 2015 CIP
WAPW Eng\PROJECTSIA- SW Projects \CBD Sewer Rehabilitation (91140203) \Constructiominfo Memo JC Alia CO #3 05 -08 -15 rt gl sb1.docx
16
ALIA CHANGE NO. 3
BACKUP DATA
MPC APRIL 25.2O15
APE MANHOLE
CONTINGENCY USED BY MICHELS
ALIA'S LAST INVOICE
CREDITS
UNIT
MICHELS
$ 32,118.97
SCHEDULE
$ 238130J0
TONS
PRICE
CREDIT
YfDA%
ALIA
$ 81.245.27
TAX
n 22,622.36
BACKFILL
95.00
$ 50.00
$ 4,750.00
$ 5,201.25
PROJECT CONTINGECY
$ 113,364.24
SCHEDULE B
$ 175,317.67
YDA2
TAX
$ 16,655.18
HMA PATCH
10.00
$ 300.00
$ 4,800.00
$ 5,256.00
MICHELS
TOTAL
$ 452,725.31
W/TAX
TOTAL $ 9.550.00 $ 10,457.25
CREDIT
MICHELS FINAL INVOICE YNTAX
$ 171,530.07
TO MARCH 30, 2015
MICHELS BASE CONTRACTWJTAX
$ 160.594.80
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMIIIIIIIIIIIIIIIIIIII
CHANGE
CONTINGECY USED BY MICHELS
$ 10.035.18
ALIA TOTAL
TOTAL TO MARCH 30, 2015
s 452,725.31
'
CHANGE ORDER #3
$ 91.152.15
ViC0<
ORDER #3
YfDAX
PROJECT CONTINGECY
WOAK NOT DONE
19.498.67
W/TAX
PIPE REPAIR
$ 77,269.40
$ 84.009.99
CONTINGENCY TOTAL
$ 113,364.24
TOTAL TO DATE
$ 563,376.12
W/TAX
PIPE CLEANING
$ 5,974.57
$ 6,542.15
CONTINGECY USED BY MICHELS
$ 10.935.18
TOTAL
$ 83,243.97
$ 91,152.15
REMAINING CONTINGECY
$ 102,429.06
ALIA CONTRACT
ALIA ORIGIANAL CONTRACT
400.226.33
W/TAX
WORK NOT
UNDER RUNS & CREDITS
* 10.457.25
COMPLETE
Y07AX
REMAINING CONTINGENCY
102.429.06
SEA COATING
$ 17.780.00
9.409.10
TOTAL FUNDS
518.11270
RESTORATION
$ 27.00
29.57
TOTAL
*17.807.00
9.488.07
ALIA TO DATE
$ 563,376.12
W/TAX
TOTAL FUNDS
$ 519,112.70
W/TAX
FROM 2015 CEO
$
PROJECT
CITY OFTWKVVLA CAPITAL PROJECT SUMMARY
2015 to 2020
PROJECT:
CBD Sanitary Sewer Rehabilitation Project No. 91140208
The osbea�uounon�epipe in the CBD(commem�| business die�oViaappmxm�e�45yeam�dand
D���N]PD�m'
'
becoming soft. Slip lining the pipe will reinforce the strength with little impact to roadways and minimal excavation.
|f the pipe ooUopoou.the etne��wiUhave 0obe excavated and the cost of the mpoinswiUbooign�conL|nthe
�U�UH�A�|��'
'
last five years we have had two major pipe failures on Andover Park West.
STATUS:
A Public Works Trust Fund loan was successfully obtained in 2012 for construction.
Dx4|NT.|DURuCT:
Reduced maintenance and repair costs.
20
The |imi�of the 2U13pn4ectioAPVVtn APE hnmK0ink|er Blvd hoG18(DhGt and wiUnow indudothe repair
��x8K8�NT'
to the sewer under the railroad tracks.
FINANCIAL Through Estimated
EXPENSES
Design
159
33
20
20
20
20
20
292
Const. Mgmt.
87
120
120
120
120
120
687
Construction
639
900
900
900
900
900
5,139
TOTAL EXPENSES
159
759
1 1,040
1 1,040
1 1,0401
1,040
1 1,040
1 01
01
6,118
FUND SOURCES
Awarded Grant
0
PWTF/Proposed PW1
45
250
455
750
Mitigation Actual
0
Mitigation Expected
0
Utility Revenue
114
509
585
1,040
1,040
1,040
1,040
0
0
5,368
TOTAL SOURCES
169
759
1,040
1,040
1,040
1 1,040
1 1,040
1 01
01
6,118
2015 2020 Capital Improvement Program 71
•
5A
City of Tukwila i
Jim Haggerton, Mayor
Mayor Haggerton
Bob Giberson, Public Works Director
Mike Cusick, PE, Senior Program Manager
May 8, 2015
SUBJECT: CBD Sanitary Sewer Rehabilitation - Construction
City Project No. 91140203, Contract No. 14-154
Project Completion and Acceptance
ISSUE
Accept contract as complete and authorize release of retainage.
BACKGROUND
On March 11, 2013, City staff received a call from a business owner on Andover Park East
reporting that sewage was coming up in his parking lot. City staff discovered that the 12-inch
pipe between Andover Park West and Andover Park East was full of sewage and not flowing.
The next day, staff noted gravel in the downstream manhole and determined that the sewer
pipe had failed and a sink hole had formed near the railroad tracks. Council declared an
Emergency with Resolution No. 1793.
Notice to proceed for Contract No 14-154 with Michels Corporation, of Salem Oregon,
was issued on December 9, 2014. Michels Corporation relined 2,444 feet of sanitary
sewer pipe in the CBD.
Contract Award Amount (without sales tax) $146,662.00
Change Order No. 1 (Pre Liner) 9,518.46
Cost Over-runs 468.00
Sales Tax at 9.5% 14,881.61
Total Contract Amount $171,530.07
Council is being asked to formally accept the project and authorize the release of
retainage, subject to standard claim and lien release procedures for the CBD Sanitary
Sewer Rehabilitation Contract No. 14-154 with Michels Corporation, in the final amount
of $171,530.07 and consider this item on the Consent Agenda at the May 18 2015,
Regular Meeting.
Attachment: Notice of Completion Contract No. 14-154
I V1
WAPW Eng\PROJECTS\A- SW Projects\CBD Sewer Rehabilitation (91140203)\Info Memo Michels Close out May 8 2015 - sb.doc
❑ Original
❑ Revised #
��'i i$88 tZa
NOTICE OF COMPLETION OF PUBLIC WORKS CONTRACT
Date: Contractor's UBI Number: 601061071
, ,, ,,, Nam eh &, iYlaiing Aridress;of P..ulilic Agency Department Use Only
�� -
Ity ot I u wl a Assigned to:
6200 Southcenter Blvd STE 100
Tukwila WA 98188 Date Assigned:
UBI Number: 91- 60015919
Notice is herebv given relative to the completion of contract or project described below
Proiect Name
Contract Number
T14-154 TO
Job Order Contracting
CBD Sanitary Sewer Rehabilitation
Phone Number: 206 - 433 -1871
Yes V No
Description of Work Done/include Jobsite Address(es)
Relining of sanitary sewers in the Central Business District (CBD)
Federally funded transportation project? ❑ Yes V No (if yes, provide Contract Bond Statement below)
Contractor's Name
E -mail Address
Affidavit ID*
Michels Corporation Idphelps@michels.us
1567077
Contractor Address
Telephone #
1715 16th St SE Salem OR 97302
503- 364 -1199
If Retainage is not withheld, please select one of the following and List Surety's Name & Bond Number.
❑ Retainage Bond ❑ Contract/Payment bond (valid for federally funded transportation projects)
Name:
I Bond Number:
Date Contract Awarded
Date Work Commenced
Date Work Completed
Date Work Accepted
9/15/14
1/12/15
13/5/15
Were Su6e6fraeteirs ;used
„cin'th>is,project?
If n `please complete
AildeudumwA: ' ; Yes °❑ No
Afficlav ;t`TDi = No`8ii release wXll 1ie`granted
urikl all afdavtfs ire ltsted ”'
Contract Amount
Additions ( + )
Reductions (- )
Sub -Total
Amount of Sales Tax 9.5
(If various rates apply, please send a breakdown)
TOTAL
$ 146,662.00
$ 9,986.46
$ 156,648.46
$ 14881.61
$ 171,530.07
NOTE. These two totals must be
Liquidated Damages $
Amount Disbursed $ 163,697.64
Amount Retained $ 7,832.43
TOTAL $ 171,530.07
Note: The Disbursing Officer must submit this completed notice immediately after acceptance of the work done under this contract.
NO PAYMENT SHALL BE MADE FROM RETAINED FUNDS until receipt of all release certificates.
Submitting Form: Please submit the completed form by email to all three agencies below.
Contact Name: Diane Jaber
Title: Fiscal Specialist
Email Address: diane.jaber @tukwilawa.gov
Phone Number: 206 - 433 -1871
Department of Revenue Washinown State Depwment of
Public Works Section Labor & industries
(360) 704 -5650 Contract Release
PWC @dor.wa.gov (855) 545 -8163, option # 4
ContractRelease @LNI.WA.GOV
Employment Security
Department
Registration, Inquiry,
Standards & Coordination
Unit
(360) 902 -9450
publicworks@esd.wa.gov
REV 31 0020e (4/28/14) F215- 038 -000 04 -2014
1801
(Addendum A: Please List all Subcontractors and Sub -tiers Below
This addendum can be submitted in other formats.
Provide known affidavits at this time. No L &I release will be granted until all affidavits are listed.
Subcontractor's Name: UBl Number: (Required) Affidavid ID*
BC Traffic LLC 602178781 674853
Bravo Environmental NW Inc 602946216 569349
For tax assistance or to request this document in an alternate format, please call 1- 800 - 647 -7706. Teletype (TTY) users may use the
Service by callinc 711.
REV 31 0020e Addendum (04/28/14) F215 -038 -000 04 -2014
`AI