Loading...
HomeMy WebLinkAboutPermit 5363 - Nordstrom - ReroofCITY OF TUKWILA Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 -; 1 BUILDING PERMIT Work to be done Site Address Building Use Property Owner_ Address Contractor Address RE, ROOF PERMIT # 3 Control # 88 -240 1020 - 1040 ANDOVER PK W Suite # Assessors Tenant NORDSTROM - THEROGARD Account # Phone #(503) 297 -8029 Zip 97221 Phone # 947 -7674 Zip 98023 sFA PORT .1 NDUSTRY GROUP 5319 S.W. WESTGATE DR. PORTLAND. OR LYNX ENTERPRISES #LYNXE 184 Bel 417 S.W. 363 PL FEDERAL WAY FOR BUILDING PERMIT ONLY Approved for Issuance By: Sq. Ft. 175T-171 . Office warehouse Retail Other IOcc. Load 2nd F1, 3rd F1, '1f Total Fire Protection: ❑ Sprinklers ❑ Detectors Zoning 0111 Type of Construction Special Conditions . /WillDate: ees sq. ft. @ 1st F1. $ sq. ft. @ 2nd Fl. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt #p9011 $ 815.00 Receipt # $ Receipt # $ Receipt #Lj3O $ 3.50 Receipt # $ Receipt # $ 818.50 FOR SIGN PERMIT ONLY ❑ Permanent ❑ Temporary [] Single Face Building face 0 Double Face J Wall Mounted Setbacks: Front 0 Free Standing ❑ Other Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions 11115 PERMII BECOMES NULL AND VOID IF WOR ABANDU EU FUR A PERIOD OF 180 DAYS AT I HEREBY C T.IfY THAT 1 HAVE R D GOVERNING T 1ST E OF WORK WILL VIOLATE OR CANC >��; PROVISIO Signed CONSTR CTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR WORK IME AFTER WORK IS COMMENCED. APPLICATION AND KNOW THE SAME TO BE TRUE THER SPECIFIED HEREIN OR NOT. THE GRA ESTATE +'r LOCAL LAW REGULATING Date 15 SUSPENDED OR ECT. ALL PROVISIONS OF LAWS ANU ORDINANCES ERIIIT FOES NOT PRESUME TO GIVE AUTHORITY TO THE PERFORMANCE OF CONSTRUCTION. I hereby affirm that I am Contractor (signature)_____. TORS DECLARATION d Professions Code, and Date -IIDER DECLARATION ( ) I, as owner of the property, or my employ with wages as their sole compensation, will do the work, and the structure is offered for sale. l 1 I, as owner of the property, am exclusively contracting with licensed contractor's to construct the project. Owner (signature)_____, s f force and effect. Date not intended or (! CITY OF TUKWILA Building Division j2 6200 Southcenter Boulevard r Tukwila, Washington 98188 ' (206) 433 - (F1-9 BUILDING PERMIT PERMIT it 5 .3 r` Control #1 88 -240 Work to be done l e• ROOF Site Address 1020 - 1040 ANDOVER PK W u to errant '��1 �' f '•� Building Use Assessors Account # Property Owner sr•A PnRT .INDUSTRY -GROUP Phone Address 5319 S.W. WESTGATE DR. PORTLAND, OR Contractcr LYNX ENTERPRISES JLLYNXE 184 BO Address 417 S.W. 363 PL FEDERAL WAY W FOR BULLING PERMIT ONLY Approved for Issuance By: Sq. Ft, Office Wareho Storageus/ e Retail Other Occ. Load st n. • !lJ4 otal Fire Protection: 0 Sprinklers J Detectors Zori irly_.._ .01 Type of Construction _ Special Conditions . 297 -8029 Zip 97221 Phone i ip Z947 -7674 98 Date: `Y y ,14)1 ees sq. ft. !l st sq. ft. @ 2nd F1. sq. ft. @ other sq. ft. @ other Total Valuation of Construction S S S.••■•=141■■■■•■■••■ Bldg. Permit Fee Plan Check Fee Demolition Surcharges Other Other TOTAL Receipt 00;%',1 S_, 815.00 Receipt 0 S Receipt 0 S`" Receipt 0,41,1 31) S 3,50 Receipt 0 S� Receipt N S '� lowoo 41111110P 1111411141PWW0011111 818.50 FOR SIGN ?ERMIT ONLY r1 0 Permanent J Temporary 0 Single Face Building face 0 Double Face 0 Wall Mounted Setbacks: Front 0 Free Standing [] Other Side Side Rear Square Footage of each sign face Total square footage of sign Specia, Conditions MIS PERMI' BECOMES NULL ANU VOID IF WOR ABANDONED FAR A PtR1U0 OF 180 DAYS AT I HEREBY CE LZY THAT I HAVE R GOVERNING ! IS -T E OF WORK WILL VIOLATE Ok CANC PROVISIO CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION uR .URK I5 ')1:St'ENUEO OR IME AFTER'WORK I5 COMMENCED. 0 ND KAMINED TH ISSy PL 1 H AMp6r�OTH Signed_ APPLICATION AND KNOW THE SAME TO BE TRUE THER SPECIFIED HEREIN OR NOT. THE GRA R_.STATE I.0R, LOCAL LAW REGULATING i Date COR A CT1 ECT. ALL PROVISIONS OF LAWS ANU ORDINANCES E', IT DOES ROI PRESUME TU GIVE AuTNORITY 10 THE PERFORMANCE OF CONSTRUCTION. 0 CO ? 'CTORS DECLARATION d Professions Code, and Date I hereby rtfirm that 1 wn Contractor (signaturel_ _, -ILDER DECLARATION ( 1 1, a, owner of the property, or my employs s, with'wages as their sole compensation. will do the work, and the structure is not intended or offered for sale. ( 11, at owner of the property. am exclusively contracting with licensed contractor's to construct the project. Owner icilnatural Date_ _. e is( 2 t'1 force and effect. • • .c. CITY OF TUKWILA ( Building Division 6200 Southcenter Boulevard Tukwila, Washington 98188 (206) 433 - /FP'? BUILDING PERMIT PERMIT # S 3 , Control # 88 -Z40 Work to be done R5' ROOF Site Address 770-70 - 1040 ANDOVER PK W Suite # Tenant - THER GARD Building Use Property Owner Address Contractor Address Assessors Account # _SEA PORT J NDUSTRY -GROUP 5319 S.W. WESTGATE DR. PORTLAND, OR LYNX ENTERPRISES #LYNXE 184 Bd 417 S.W. 363 PL FEDERAL WAY W FOR BUILDING PERMIT ONLY Approved for Issuance By: S Ft. Sq. • Office Storage/ Warehouse Retail Other Occ. Load 1st F1. 2nd F1. 3rd F1. l ,` � 11'" i Total _ Fire Protection: ❑ Sprinklers ❑ Detectors Zon i rry C 10 Type of Construction Special Conditions . Phone # (503) 297 -8029 Zip 97221 Phone # 947 -7674 /7 Zip 98023 Date: ees sq. ft. @ 1st Fl. sq. ft. @ 2nd F1. $ sq. ft. @ other $ sq. ft. @ other $ Total Valuation of Construction $ Bldg. Permit Fee Receipt # p�0r1 $ 815.00 Receipt # $ Plan Check Fee Demolition Surcharges Other Other Receipt # $ Receipt #1.�?3() $ Receipt # $ Receipt # $ 3.50 TOTAL $ 818.50 FUR SIGN PERMIT ONLY ❑ Permanent ❑ Temporary ❑ Single Face ❑ Double Face Building face ❑ Wall Mounted J Free Standing J Other Setbacks: Front Side Side Rear Square Footage of each sign face Total square footage of sign Special Conditions THIS PERMIT BECUMES NULL AND V010 IF WOR ABANDUNEU FUR A PERIOD OF 180 DAYS AT 1 HEREBY C 1�Y THAT 1 HAVE R. 0 GOVERNING T lS TY'E OF WORK WILL VIOLATE UR CAR � �./_PROVISIO Signed CONSTRUCTION AUTHORIZED IS NOT COMMENCED WITHIN 180 DAYS, OR IF CONSTRUCTION OR wURK IS StSPENUEO OR IME AFTER WORK IS COMMENCED. 1 I hereby affirm that I am Contractor (signature) APPLICATION AND KNOW THE SAME TO BE TRUE THER SPECIFIED HEREIN OR NOT. THE GRA ER__STATI/.70k LOCAL LAM REGULATING Oate D COR'ECT. ALL PROVISIONS OF LAWS ANU ORDINANCES A E IT UES NOT PRESUME TO GIVE AUTHORITY TO CTIs 1 0.R/ THE PERFORMANCE OF CONSTRUCTION. CTORS DECLARATION d Professions Code, and Date BUILDER DECLARATION ( ) 1, as owner of the property, or my employ s, with•wages as their sole compensation, will do the work, and the structure is not intended or offered for sale. ( 1 1, as owner of the property, am exclusively contracting with licensed contractor's to construct the project, Owner (signature)_ ____ Date_ si t'l force and effect. t CITY OF TUKWILA Building Division' 6200 Southcenter Boulevard. Tukwila, Washington 98188 (206) 433 -1849 INSPECTIIN RECORD PERMIT # S- 3 C 3 Type of. Inspection Site Address /G000 r - - ect Project A/_ L . /< Requester '21144 T.lL Phone # 2 fir- 5" 7 r 7 Special Instructions Date Wanted Inspection Results /Commen G((1 -/ ili'9)- Inspector ,ni ..52:/1/5JI`1/ Date if �+ i4E C t10N �../ � OORpORA KP�Rh� VMS AS o, s E1000b E`tIN A p7ooe Her+ coax, Nr iuooa t0 q L110,5 Karnak #97 Fibrated Aluminum Asphalt Roof Coat- ing Now Has a U.L. Class "A" Rating, When Used With The Following Modified Bitumen Single -Ply Membrane Systems. Gat — Bitec — Celotex — Tarmac — Arc — Rhoflex — Der - bigum —1H-Ply — Dibiten USA — U.S. Intec /Brai — Not Bitumi U.S., Inc. — Others Pending. One coat of Kamak #97 Fibrated Aluminum Asphalt Roof Coating will extend the life of Modified Bitumen Membrane Roofs not only by limiting fire - spread (as in- dicated by the U.L. Class "A" Rating), but its high aluminum content and excellent reflectivity afford solar protection and weather durability. The special formula of Karnak #97 increases leafing of aluminum flakes to the surface of the asphalt coating, creating a more uniform and a tough metallic surface. One coat of Karnak #97 applied at one to two gallons a square is all that's needed to enhance the life and look of modified bitumen membrane roofing. KARNAK CORPORATION 330 Central Avenue, Clark, NJ 07066 (201) 388 -0300 Toll Free 1 -(800) 526 -4236 KARNAK SOUTH INC. 1010 S.E. 20th Street, Port Everglades, Fort Lauderdale, FL 33316 UNDERWRITERS LABORATORIES INC. 333 PFINGSTEN ROAD • NORTNRROOK, ILLINOIS 60082 an independent, not - for - profit organization testing for public safety December 13, 1985 Dibiten U.S.A. Mr. Rudi Bianchi 4301 E. Firestone Blvd. Southgate, CA 90280 Our Reference: File R11659/85NK20219 Dear Mr. Bianchi: WED O E ; i 8 3985 This is to advise you that we have completed our Investigation of your Dibiten "4 Poly" modified bitumen roofing membrane over combustible decks (Project 85NK20219). T E S T R E C O R D SAMPLES: A representative of Underwriters Laboratories Inc. visited your manufacturing facility, witnessed the manufacture, quality control tests, and batching of your "4 Poly" membrane. Our Casualty and Chemical Hazards Department conducted chemical verification tests on the samples selected by our representative..__ Their•results are summarized on the attached sheet. The test samples for the fire tests were constructed as follows: System la -• 2 in. Thick of UL Classified fiberglass insulation, followed by one layer of UL Classified Type G -2 base sheet mechanically fastened to the deck. Followed by one layer of "Dibiten 4 Poly" modified roofing membrane heat fused into place, covered with "Dibicoat" roof coating applied at a rate of 1 -1/2 gal /100 fta. System lb - Two layers of 15/16 in. UL Classified fiberglass insulation with 6 in. offset joints covered with one layer of UL Classified Type G -2 base sheet mechanically fastened into place over the test deck constructed with 15/32 in. plywood. Followed by one layer of "Dibiten 4 Poly" modified roofing membrane heat fused into place, covered with " Dibicoat" roof coating applied at a rate of 1 -1/2 gal /100 fta. Look For The a Listing or Classification Mark On The Product Phones 1312) 243400 NCI WWI Ne.s 2.44347 Coble: uUNC NORTHBROOK, IL Yalu No.s 201231 R11659 December 13, 1985 Page 2 FIRE TESTS: Class A fire tests were conducted on the above samples. These tests were conducted in accordance with the Test Standard UL 790, "Tests for Fire Resistance of Roof Covering Materials ", (ASTM E -108, "Fire Tests of Roof Coverings "). In the spread of flame and intermittent flame tests described in this report, the temperature of the test flame, as measured by a No. 14 gauge chromel- alumel wire thermocouple located as described in UL Standard 790, was found to be 1400 ± 20 °F. The physical appearance of the test flame when the test apparatus was calibrated for flame temperature, was generally triangular in shape, being about 3 ft wide at the deck's leading edge and gradually narrowing to a width of approximately 6 in. at the top of the 52 in. long calibration deck, with licks of flame extending approximately another 1 ft. The wind velocity required by UL 790 was determined by taking readings on a smooth deck (40 in. wide and 52 in. long) midway up the deck at the center and 3 in. from each vertical edge with a vane type anemometer and timer. The velocity measured at an incline of 5 in. /ft was found to be 1050 ± 50 ft /min (12 ± 1/2 mi /h) with the carriage in position. The results of these tests are summarized below: SPREAD OF FLAME TEST System la - One layer of UL Classified 2 in. fiberglass insulation covered with one layer of UL Classified Type G -2 base sheet and "Dibiten 4 Poly" modified roofing membrane heat fused . into place and coated with UL Classified "Dibicoat" roof coating applied at a rate of 1 -1/2 gal /100 ft2. Slope Of Maximum Flying Test System Deck Flame Brands Deck No. No. (in. /ft) Spread (ft) Produced Exposure 1 1 i /12 4 -1/4 None None 2 1 i /12 2 -1/2 None None This test was conducted on duplicate test decks positioned at an incline of 1/2 in. to the horizontal foot. At no time during these tests were any flying flaming brands of roof covering material produced or did exposure of the roof deck occur. Also, there was no significant lateral spread of flame from the path directly exposed to the test flame. FIRE TESTS: Class A fire tests were conducted on the above samples. These tests were conducted in accordance with the Test Standard UL 790, "Tests for Fire Resistance of Roof Covering Materials ", (ASTM E -108, "Fire Tests of Roof Coverings "). In the spread of flame and intermittent flame tests described in this report, the temperature of the test flame, as measured by a No. 14 gauge chromel- alumel wire thermocouple located as described in UL Standard 790, was found to be 1400 ± 20 °F. Tb.e physical appearance of the test flame when the test apparatus was calibrated for flame temperature, was generally triangular in shape, being about 3 ft wide at the deck's leading edge and gradually narrowing to a width of approximately 6 in. at the lop of the 52 in. long calibration deck, with licks of flame extending approximately another 1 ft. The wind velocity required by UL 790 was determined by taking readings on a smooth deck (40 in. wide and 52 in. long) midwa;r up the deck at the center and 3 in. from each vertical edge with a vane type anemometer and timer. The velocity measured at an incline of 5 in. /ft was found to be 1050 t 50 ft /min (12 t 1/2 mi /h) with the carriage in position. The results of these tests are summarized below: SPREAD OF FLAME TEST System la,- One layer of UL Classified 2 in. fiberglass insulation covered with one layer of UL Classified Type G -2 ,lase sheet and "Dibiten 4 Poly" modified roofing membrane heat fu:;ed into place and coated with UL Classified "Dibicoat" roof coaf:ing applied at a rate of 1 -1/2 gal /100 fta. Slope Of Maximum Flying Test System Deck Flame Brands Deck No. No. (in. /ft) Spread (ft) Produced ExpDsure 1 1 i/12 4-1/4 None Vone 2 1 i/12 2-1/2 None /lone This test was conducted on duplicate test decks positioned ;:,t an incline of 1/2 in. to the horizontal foot. At no time during these tests were any flying flaming brands of roof covering material produced or did exposure of the roof deck occur. ,Also, there was no significant lateral spread of flame from the path directly exposed to the test flame. R11659 December 13, 1985 Page 3 INTERMITTENT FLAME TEST System lb - Two layers of 15/16 in. UL Classified fiberglass insulation (with 6 in. offset joints) covered with Type G -2 base sheet and "Dibiten 4 Poly" modified roofing membrane heat fused into place, coated with UL Classified "Dibicoat" roof coating applied at a rate of 1 -1/2 gal /100 ft2. The intermittent flame test was conducted on duplicate test decks positioned at an incline of 1/2 in. to the horizontal foot. Similar results were obtained in both tests. At no time during these two tests was any smoke or asphalt visible at the horizontal joint. At no time during these two tests were any flying flaming brands of roof covering material produced or did exposure of the roof deck occur. Also, at no time during these tests were any sparks or flames noted on the underside of the test deck. These results comply with the Class A requirements. A discoloration of the plywood resulted during each of these two test. BURNING BRAND TEST System lb - Two layers of 15/16 in. UL Classified fiberglass- insulation (with 6 in. offset joints) covered with Type G -2 base sheet'and "Dibiten r Poly" modified roofing membrane heat fused into place coated with UL Classified "Dibicoat" roof coating applied at a rate of 1 -1/2 gal /100 ft1. For each of four test decks at an incline of 1/2 in. to the horizontal foot, a well ignited Class A burning brand was positioned over the "T" joint formed in the plywood deck. At no time during these tests were any flying flaming brands of roof covering material produced or did exposure of the roof deck occur. Also, at no time during these tests were any sparks or flames noted on the underside of the test deck. These results comply with the Class A requirements. A slight discoloration of the plywood surface resulted during each of these four tests. R11659 December 13, 1985 Page 4 CONCLUSION: Based upon the above fire test results, Classification can be established. The Follow -Up Service Inspection Procedure is being revised to include "Dibiten 4 Poly" modified bitumen roofing membrane. The Classification Cards are being established to include the following: Sheathing material (modified bitumen) and roof insulation, for use in construction of built -up roof coverings as specified below (minimum specified) . CLASS A 1. Limited to noncombustible decks at inclines not exceeding 1/2 in. to the horizontal foot. One layer of UL Classified Type G -2 base sheet mechanically fastened to the deck, covered with one layer of sheathing material ( "Dibiten 4 Poly ") heat fused into place and surfaced with one coat of UL Classified roof coating ( "Dibicoat ") applied at a rate of 1 -1/2 gal /100 ft2. 2. Limited to noncombustible decks at inclines not exceeding 1/2 in. to the horizontal foot. One layer of UL Classified-- roof insulation (perlite, fiberglass, or vegetable fiber) 'not exceeding 2 in. in thickness covered with one layer of UL Classified Type G -2 base sheet mechanically fastened to the deck, followed by one layer of sheathing material ( "Dibiten 4 Poly ") heat fused into place and surfaced with one coat of UL Classified roof ( "Dibicoat ") applied at a rate of 1 -1/2 gal /100 ft'. 3. Limited to- noncombustible and 1/2 in. (minimum) thick plywood decks at inclines not exceeding 1/2 in. to the horizontal foot. Two layers of UL Classified 15/16 in. fiberglass insulation with joints in the insulation offset 6 in. with the joints in the roof deck mechanically fastened into place, covered with one layer of sheathing material ( "Dibiten 4 Poly ") heat fused into place and surfaced with one coat of UL Classified roof coating ( "Dibicoat ") applied at a rate of 1 -1/2 gal /100 ft=. R11659 December 13, 1985 Page 5 UL's testing of the above was for the purpose of leading to a program of Classification and Follow -Up Service. Product Classification involves much more than merely testing the product in accordance with a designated Standard. It also involves identification of and selection of materials to be tested at the factory where produced. It involves the preparation of a detailed inspection document if the product is found to conform. It involves the implementation of an ongoing program of unannounced inspections at the factory and countercheck tests to verify on a continuing basis that the product, as produced, is identical to the product tested. Finally, product Classification involves the use of a Classification Mark on that part of a manufacturer's production that is found to be in conformance. The use, purchase, and distribution of such Marks are rigorously controlled by the Laboratories. The Classification Mark of Underwriters Laboratories Inc. on the containers or wrappers is the only method provided by Underwriters Laboratories to identify roof covering materials which have been produced under our Follow -Up Service. This letter concludes the investigation being conducted under Project 85NK20219. We have advised our Accounting Department to issue a final billing for this project. Underwriters Laboratories Inc. authorizes the addressee to__, reprod"uce this - Report `provided it is reproduced in its entirety. _ Should you have any questions concerning this project, please contact me. Very truly yours, DOUGLAS C. MILLER Engineering Assistant Fire Protection Department DCM :bg L17 cc: Mr. Norm Christensen Pabco Roofing Products 1014 Chesley Ave. Richmond, CA 94801 Reviewed by: 1 GL L. A. PLENCNER Engineering Team Leader Fire Protection Department R11659 December 13,198.5 Page 6 PHYSICAL CHARACTERISTICS OF "DIBITEN 4 POLY" MODIFIED BITUMEN ROOFING MEMBRANE MANUFACTURED BY DIBITEN U.S.A. Test Results UN- Modified Asphalt Coatin oftening Point, °F (RB) 102 Modified Asphalt Coating - Softening Point, °F (RB) Penetration Core Weight, lb /100 ft2 Membrane - Weight, lb /100 ft2 Thickness, in. 311 17 3.80 TECHNICAL SHEET Product Specifications dibCen poly/4 DIBITEN POLY 4 Product Name Dibiten Poly 4 Product Type A.P.P. Modified Bitumen Application Method Torch Applied Reinforcement Nonwoven Polyester Roll Weight 88 lbs. (± 1%) Roll Length 10 m. ( ±1 %) approx. 33 ft. Roll Width 1 m. ( ±1 %) approx. 39 in. Membrane Thickness 4 mm. ( ±5 %) Surface Color Black Surface Finish Smooth Gross Area per Roll Approx. 107.6 sq. ft. Net Coverage per Roll Approx. 95 sq. ft. dibitenwn 4301 East Firestone Blvd. South Gate, CA 90280 (213) 564-7220 (213) 564-8364 Toll Free: 1- 800 - DIBITEN 1-800-367-8315 (Calif.) EMEMENONSUMOUSWEINEMBIESSEGMOOMINI TECHNICAL SHEET `.7 Technical Data dib4n polg/4 • Slipping Test Temp. 194° F, Inclination 90 ° (7 Day Test) Slippage less than 1 mm Water Resistance " After 28 Day Immersion Absorption less than 0.5% Weight Loss less than 0.1% Water Vapor Transmission * Nil Resistance To Low Temperatures (Flexibility) Specimens were tested after 2 hours at a temperature of +14° F, then bent at 180° over a 20 mm 8 rod in 5 seconds. No cracking at + 14° F Resistance To Aging Resistance recorded by Weather -O -Meter (radiations of sunlight coupled with spout of water and subjected to thermal changes). No changes recorded after 1000 hours Running Point Testing A specimen of material is suspended vertically in a thermostatic oven. The temperature recorded is the highest which does not give place to any running or melting of the material. Running Point More than + 266 ° F Resistance To Tensile Stress And Ultimate Yield Elongation Tensile Strength velocity 100mrrt/minute. Test Temperature + 68 ° F. Resistance (kg/5cm) Longitudinal 80 Resistance (kg/5cm) Transversal 65 Elongation Longitudinal 50% Elongation Transversal 50 °/Q Dimensional Stability (to heat) After Thermal Action • Specimen is heated in an oven for 3 days @ 176 °F, then cooled for 24 hrs. @ room temp. Longitudinal :I.5% Transversal ± 0.2% • The above data was determined according to UNI 8202 norms, the European standard for modified bitumen. dibitenw� Product Advantages Dibiten Poly 4 has received approval from the following agencies: Underwriters Laboratories (Class A ). Dade County, Fla. (Wind Uplift). SBCCI (Southern Building Code Congress International). ICBO (International Conference of Building Officials). • Strong, Durable, Flexible Dibiten Poly 4 membrane is reinforced with a nonwoven polyester core. It has elongation capabilities of up to 50 %, plus strength and resilience. • Easy to Apply Dibiten Poly 4 is easy to install using a propane torch and trowel. No need for costly kettles and other equipment or large crews. Dibiten Poly 4 is resistant to the effects of weathering, pollution, aging, and ponding water. (See Technical Data ). Flashing is made from the membrane on the spot. • Versatile Dibiten Poly 4 is ideal for new roofing, reroofing and general waterproofing. Dibiten Poly 4 does not require ballasting. Dibiten Poly 4 roof systems are easy to maintain. • Warranty Dibiten Poly 4 roof systems carry up to a twelve year manufacturer's warranty, or up to twenty years when used in two plies. • Assistance Technical assistance and application & safety guidelines can be obtained from DibitenUSA by contacting the manufacturing plant at the toll free number listed below: Toll free 1- 800 - DIBITEN 1- 800 - 367 -8315 (CA) Sea -Port Industry Group division of Sea -Port Investments, Inc. July 21, 1988 Mr. David Link LYNX ENTERPRISES 417 SW 363rd Place Federal Way, Washington 98023 Sylvan Westgate Bldg. • Suite 245 6319 S.W. Westgate Drive • Portland, Oregon 97221 Phone (503) 297 -8029 RE: M -4 Building Roof, Southcenter Dear Dave: We received your contract proposal today. Thank you for.the prompt response. In our phone conversation there were several other features or conditions regarding this roof job that you proposed and agreed would be included in th:i.s project at the $1.20 /sq. ft. or $152,000.00 price. These are listed below as items to be included by reference to your contract proposal. Would you please confirm: 1. Use of a basing tape system, with 3/4" nails, 2. Rolled -ony Karnak fibrated emulsion tb: flow.=.coat at-,2 gallons per square. . 3. Installation of a new wood cripple cross -brace in the entry hatch area where roof joists were cut. 4. New leads for sumps and drains. 5. Resealing of the new heat vents, and protection of existing electrical conduit. 6. Two -ply APP modified bitumen on all skylights, vents and roof protrusions. 7. Pabco also to supply twelve -year written warranty on labor and materials. 8. Lynx Enterprises to begin and complete job in August, 1988. (Approximately•25, days.) One payment modification I would like to make for our own cash requirement . considerations, is to split the $65,720.00 advance into two payments as follows: Sea -Port Industry Group 1. $32,860.00 at the start of work. 2. $32,860.00 two weeks later when job is half completed. We have .a credit line at the First Interstate Bank of Oregon that more than covers the entire project. As usual, Lynx Enterprises will take every precaution to protect building occupants and their property as well as carry all necessary insurance to cover any claims for damages and injuries resulting from the work. Owner will' be held harmless from liability for payment of payroll and related taxes, including supplier demands in the form of mechanics and materialman liens filed on the property. If this meets with your approval, please sign and return one copy so we can start the job. .Please advise as soon as possible. Sincerely yours, SEA -PORT INDUSTRY GROUP Lloyd B. Rosenfeld/ President APPROVED: Lynx Enterprises *ILA 1908 City of Tukwila 6200 Southcenter Boulevard Tukwila Washington 98188 COW 433.1800 Gary L. VanDusen, Mayor • NOTICE TO ALL ROOFING CONTRACTORS: For all reroofing and roofing projects that require a fire retardant roof covering under the provisions of Section 3202 (b), 1985 UBC, the Tukwila Building Department will require a written statement from the installer stating the following (or some- thing similar). This statement must be provided before or at the time of final inspection. I HAVE INSTALLED A ROOF MEMBRANE ASSEMBLY, INCLUDING INSULATION IF APPLICABLE, CONSISTING OF (Manufacturer) , SPECIFICATION # DATA SHEET ENCLOSED, WHICH MEETS OR EXCEEDS THE REQUIREMENTS FOR CLASS A OR CLASS B ROOFS. THIS ROOF WAS INSTALLED AT (Address) UNDER CITY OF TUKWILA BUILDING PERMIT NO. The statement will include the name of the roofing company that installed the . roof, signature of installer, and date. . CIIY Of TUKWILA e'64:, b2 ttgitMashterBoulevard BUIL ^ qNG PERMIT APPLICP 'ION Control # (-1C-7 (206)- 433 -1849 q Site Address '1)Z7 �y0 0/0 IL • A • 6e Suite# Floor# Project Name /Tenant A i ems. - '. 0 .,.Ae-O____ Valuation of Constructio /5 000 -- Asses ors Account# .0, . Phan Property Owner �i 4 Address J � � �� ' G�PBT PTE , OL,3 JD � nee Zip cv72.2.1 Applicant ik-A(, C/JyE -1 Phone -7366, ,) Address Cly D. 3 s-f ("/ - I.la� -C. (JJ49 Zip 9807-3 Architect /Engineer Phone Address Zip Contractor A,, ._ , r ', S License# / J may &KE Ref-8i Phone %7-76,--74- � -,1 ' Zip Class of Work: [] New C1 Addition Tenant Improvement [l Remodel (residential) KReroof Demolition 7 Interior Demolition D Other Describe work to done e, A '0 �. ST /Ic-1%J --77Ca , o.� ,e J a ) �� '. - 6/:14- CS ti..) 4 Type of Const. (UBC) Occ. Group (UBC) Square footage of entire building Square footage of tenant space Building Use Will there be a change of use? (] Yes jNo If yes, describe change of use, including square footages of changed areas / %. Will there be storage or use of flammable, combustible azardous materials on the premise or area of construction? 4:21 Yes Q No If yes, explain I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLIC Y' D KNOW THE SAME TO BE TRUE AND CORRECT AND THAT I HAVE THE PROPERTY i^' '' AUTHORIZ'TIO 'TO DI HIS WORK. Applicant /Authorized Agent (signature) SI ,`..` Date 8/5/2'S (print me) big L)t r _ Contact Person (please print) 0 /L2/ ,- Phone R3g'849 OFFICE USE ONLY FEES: Building Permit Fee (000/322.100) $ V,..;.0 -m, Receipt# '7(736 Date Paid -S/-611 Plan Check Fee (000/345.830) Receipt# Date Paid Bldg Code Sur Charge (000/386.904) 3.50 Receipt# Date Paid Energy Sur Charge* (000/386.907) Receipt# Date Paid Other ( ) Receipt# Date Paid II V *New construction only TOTAL (OWES: $ ) ___.Li... SQUARE FOOTAGE /BUILDING USE INFORMATION Square Foot�Iae of Entire Building: FLOOR USE /Occ Type SQ.FT. OOC-' LOAD USE /Occ Typo SOFT. dm LOAD. USE /Occ Ty2 SO.FT. OCC 1nan TOTAL SQ.FT. TOTAL OCC. TOTAL TRACKING • • e, I •, si OMMEN BLDG / T- It Y - �i Approved for Issuance Type of Const. To Mahan: Date Approved: FIRE Approved (Initials) Per letter dated Fire Protection: • Sprinklers ❑Detectors PLNG / Approved (Initials) • BAR OLAND IJSE /SEPA CONDITIONS Zoning Setbacks: N S E W Parking stalls required for: Site Tenant Space Parking stalls provided: Site Tenant Space ADDITIONAL PARKING STALLS REQUIRED: PWD Approved (Initials) Per letter /plans dated F;/& ( / &603- 3826 South 306th Place, Auburn, Washington. 98002 ENTERPRISES (206) 941 -5093 CITY ofTUKWILA 6200Southcenter Blvd. Tukwila Wa.'98188. We have installed a one ply DIBITEN membrane: roof spec. book attached. Q,LkSS Es 1,..71 tz Our roof, as specified by Ray Wetherholt, coneistsof a two ply layer of Genstar #281b. fiberglass base sheet, . one torch on layer of type 4 DIBITEN torch on roofing, and a coating of Karnak fibered alumi- coa,ing. Permit #5363 Res bmitted, W 1,, ' I H 1 : 1( 1 1 ( ) 1. ' I ' A N 1 ) :\ S S O C; 1 A 'I' I S FIELD REPORT ROOFING INSPECTION FINAL INSPECTION Job No.75 /LJg Report No. 3 Page No. 1 of Job Name M "/ £kfl, Attendee's Ill = e°'t5 Date 9 -I'-813 Comments -7 ec.=-vf is. n 1 en"— r.Dco. ec.c_e 1 /J2 . G(.) At LASAIOca u9w LGl-1- Aizcz A-t=4-4 aO'7' QkFig-spo Iv 4u_ Fu4r-J..4 A04, tU Nric,i4 t.0 1 tL_ T f av epvWE.e.e A..0ELL3 ►ivtalvt<,$2 W E' . -- uo-r tgfw c —gyp . ter A P te. ervevt-L 7 5f!;r q v, 4 DOPILLIV >, .:..try 2 ' - /KC! Final r Signed Signed I'.O. '21tH2 tin nth Serve( Sinai Kirkland. 'V.\ ')ROM '?cIidt ' ;71■1' n N r. Specification #401 Nailable Deck, No Insulation Type of decks: Plywood, Wood Plank, Lightweight Insulating Concrete, Poured & Precast Gypsum Base Sheet • UL approved fiberglass base sheet type G -2 (for plywood or wood plank decks) • UL approved organic #40 (for li htweight insulating concrete and poured gypsum decks) L12 )� ns Dibiten Poly /4 • APP modified bitumen membrane reinforced with nonwoven polyester fabric (torch applied only). Coating or Ballast • 2/3 gal /100 sq. ft. of Dibicoat or equivalent or • 4001b /100 sq. ft. of 3/8" river bottom gravel applied in cold, wet emulsion Roofing Application 1. Starting at low point of roof apply one ply of fiberglass base sheet or one ply of organic base sheet. Nail base sheet 9" o.c. on side lap and stagger nail field 18" o.c. Overlap side laps 2" and end laps 4". 2. Starting at low point of roof deck torch Dibiten Poly /4 to base sheet overlapping side laps 4" and end laps 6 ". 3. Apply finish coating or ballast at rate specified above. Material Required per 100 sq. ft. of Roof Area • Fiberglass or organic base ply 108 sq. tt. • Dibiten Poly /4 107.6 sq. ft. • Dibicoat 2/3 gal. • Gravel 400 Ib • Emulsion 60 Ib SPECIFICATIONS MANUAL Specification #401 1 Nailable beck Slope 1. 19 "o.c. O G Fiberglass Base Sheet or Organic Roofers Base DlbltenPoly /4 B" Dibicoat C; or Gravel SPECIFICATIONS MANUAL