Loading...
HomeMy WebLinkAboutPermit EL08-0009 - PANDA EXPRESSPANDA EXPRESS 17100 SOUTHCENTER PY STE 100 EL08-009 Parcel No.: Address: Suite No: Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 2623049081 17100 SOUTHCENTER PY TUKW ELECTRICAL PERMIT Permit Number: Issue Date: Permit Expires On: EL08 -009 01/10/2008 07/08/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: PANDA EXPRESS 17100 SOUTHCENTER PY, STE 100 , TUKWILA WA WIG PROPERTIES LLC -SS 4811 134TH PL SE , BELLEVUE WA ROBBY GONNER 7056 S 220 ST , KENT WA Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW Phone: Phone: 253 872 -5553 Phone: Expiration Date: 12/16/2009 DESCRIPTION OF WORK: (2) 200 AMP PANELS Value of Electrical: $2,500.00 Fees Collected: $155.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: 1 G -0 11 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of w . I am authorized to sign and obtain this electrical permit. Signature: 4 Date: /lldr e" Print Name: / ' ( / 6- 7 /7i- �' , - €-4 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -009 Printed: 01 -10 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: Tenant: PANDA EXPRESS PERMIT CONDITIONS Permit Number: EL08 -009 Status: ISSUED Applied Date: 01/03/2008 Issue Date: 01/10/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: . ;�, jar -1 Print Name: � Date: ` l0 /Q doc: Cond -Elec EL08 -009 Printed: 01 -10 -2008 CITY OF TUKWILA Community Develops! Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www. ci.1ukwila. wa. us Electrical Pell No. Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: I7 00 SotAcen/e1- PA' Tenant Name: Panda 'r eSS Property Owners Name: LW/ 6 Pr-ty,et-i le S Mailing Address: S I! 1,39)% 4.44 SE King Co Assessor's Tax No.: 2 () Suite Number: /OD Floor: New Tenant: ❑ Yes Itgk.No City W19� State g,PDD6 Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: R 6124,7e /- Mailing Address: 705 6 Sou 1 ocO ,5,- Day Telephone: a?53 ` 8 72 - S S S � ( City State Zip E -Mail Address: / 1'PV /h . A @sec( c e feG jj iG . C si Fax Number: 23 - t 7 - 1/4/ . ELECTRICAL CONTRACTOR INFORMATION Company Name: Se4 * C. /27‘e_ Mailing Address: Z'5 Sac ade, Ski * Contact Person: #04 v%/l iy J r-c( E -Mail Address: 14' /7. h etSLoQ7 L e(,172. !dky/ Contractor Registration Number: 5;5972957 Q77X L-I !tiP4 1 i4 °lie. 3.? City State Zip Day Telephone: /■ 64 — k37- -7a / f Fax Number: e 53 — 8.7a —Zip 4 Expiration Date: /2 Jt 7 Valuation of Project (contractor's bid price): $ tV 5-0 v Scope of Work (please provide detailed information): — ••e)63 ?J':k/ 7 t pX.r Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Tyne of work: ❑ New ❑ Addition ❑ Service Change g ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Puget Sound Energy ❑ Seattle City Light HAApplications\Fortns- Applications On l.ine41.2007 - Electrical Permit Applicationdoc M Page 1 of 2 RESIDENT NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.0() ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits 575.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) • MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee e schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: �/ �f �, ,1)/ Print Name: /( /(/SHEZ ), 5u c-4 Mailing Address: S 22Uf - IDate Application Accepted: 0(l (Tht-vb HAUPplicationsTonns- Applications On tine\4.2007 - Electrical Pamit Apphcatioadoc bh Date: 1 5(06' Day Telephone: Zvv 4uv - 8(s 14 rT City Date Application Expires: o?—/ State g803Z Staff Initials: Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: EL08 -009 Address: 17100 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 01/03/2008 Applicant: PANDA EXPRESS Issue Date: Receipt No.: R08 -00018 Initials: JEM User ID: 1165 Payment Amount: $156.00 Payment Date: 01/03/2008 01:38 PM Balance: $0.00 Payee: SEA -TAC ELECTRIC, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 8747 156.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES PHOTOCOPIES /DUP SERVICES 000.322.101.00.0 000.345.832.00.0 000/341.690 124.00 31.00 1.00 Total: $156.00 6757 01/03 9710 TOTAL 156.00 doc: Receiot -06 Printed: 01 -03 -2008 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 146 -06 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -36'0 Pr a t: Type of Inspection: \ Address: /7/� emu« /111q, lea, Date Called: Special Instructions: Date Wanted: V '=- 0). Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: i / /� Inspe , L ,7' .7, 4/76fa Date: //2- 2. iat6 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Pro : , . �� Type of Inspection: Address: n/a0 ,L1/7)<1/1/714:4 fiAky Date Called: Special Instructions: Date Wanted: / !/ , m. Requester: 0/' -- Aa /6// /N — /)1q t f Phone No: CIA) -- S77ZA/° ,9/ c4gL,E Wproved per applicable codes. ,Corrections required prior to approval. COMMENTS: OK— stA V/ Ci6 P 0/' -- Aa /6// /N — /)1q t f CIA) -- S77ZA/° ,9/ c4gL,E 14) /T// //r% 1 ,. 'l £ ib/sc-04 iJ , 7 S ,9/'A InsPO;1G ®® 60 46l6� Date / / /'k $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: 13ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 --009 DATE: 01 -04 -08 PROJECT NAME: PANDA EXPRESS SITE ADDRESS: 17100 SOUTHCENTER PY, STE 100 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARRTMEE/N�TS: Buitdsng Divisio Public Works n Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ro Comments: Incomplete DUE DATE: 01-03-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route IV Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 01-31-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/rouling slip.doc 2 -28 -02 Look Up a Contractor, Elect i n or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SEATAEI077RW Licensee Name SEA TAC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UB1 601510212 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 7056 S 220TH ST Address 2 City KENT County KING State WA Zip 98032 Phone 2538725553 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/16/1993 Expiration Date 12/16/2009 Suspend Date Separation Date Parent Company Previous License SEATAEC131QC Next License Associated License HARGRT *974CD Master Electrician Information License HARGRT *974CD Name HARGREAVES, TOM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM AGENT 12/17/1993 HARGREAVES, TOM PRESIDENT 12/17/1993 HARGREAVES, • Page 1 of 2 https: / /fortress.wa.gov /lni/bbip /printer. aspx ?License= SEATAEI077RW 01/10/2008 t PANEL: P— Li PANEL VOLTAGE 120/208 3 0 4 W CIRCUIT CODE blank or N : NON -- CONTINUOUS BUS: 200 AMP L : LONG — CONTINUOUS DATE: 01/03/2007 TIME: MAINS: MAIN BREAKER R : DEMANDABLE RECEPTACLES JOB: 6089 AIC RATING: 11,000 K : KITCHEN NO. OF EQUIPMENT: 0 c. 1.1 ID 1- w a LOAD DESIGNATION CONNECTED VA LOAD DESIGNATION Ir 1,1 R° ul °z U DESCRIPTION N R L A B S� C ABC A B 0 C N R L DESCRIPTION 1 can p ° . 'T ± + + + + + + ± ____ \\MEWL 0 I 4200 r V%� % + + - + + + + + - + + + + + + + + + 0 ry r Illi 1111 3 2 1111 3 pi ROOFTOP UNIT #1 0 r 4 4200 D 4 5 mmh- =PEW M 5 �" / / 0 1111/ 1111 A � 46 • NW is 6 7 l ■ \ 0 0 3024 8 9 8 0 J ROOFTOP UNIT #2 \ �� ., . \ IFf ‘ i / 3024 Ik. L ' ila 10 1111 11 MI + 10 .11 1111/ 11 " " "�� 0 1� 3 "" i/ ❑ ���44, 3024 . V%yf 3024 ���/1111 � /�� 0 12 13 �1 rua 12 13 + + + - + + + 35 P2 —E�+4 0 / //./ �� 14 -r * + + + + + I- + . C.J. 14 15 .. / /.ff4/ ROOFTOP UNIT '3 1111 + + + + + ± + + + 4- + + + �� 3024 r4 4. 3024 -,r A1111/ / 0 / / /// + + + / + + 16 17 C.J. rrs 11=11 16 17 3 /y0 0 0��%1111% 7 , f 0 '/' 0 x/1111 �JIJ///1111 0 ��O %1111 0 "" r7 rrA 0 + + E.+ 18 19 18 19 1 C.J D � rte. 0 All A 0 f , 20 1111 1111 1111 u11, 1111 . + -I- --� ± ± + + + + C.J. I- `f- + + --H + 20 21 Ir / 474 ��4/ j oi`a�� -• , f� //. �-.. -` `' 4 0 ji E.J. 22 23 \ - ■ \ ^�\ ♦����� .. Ailx .♦♦��♦� . y►, C.J. + + + 22 23 ■ C.J. 111,,_ 4- ± + S A !.,.2 �� �, 0 II Affii /0 y AM1 r1111 NU 1111 Illi 24 25 IL 1Mil 11111111►Ilflllllll 24 25 0 •• 9fv _ _ 0 ��1111' 0 "" 27 II III 26 27 0 ! / �� 7ff 0/ / / /// 111 •_ �►7i■ %I�� ,,� , 28 29 0 + 0 �� f A 31 0 E.J. . 0 ///' 30 .111.11 ' . -� rA,. 31 W _II. - 32 33 W . / ff�7f47 111111111111.— J.. -_ % /� / //l 33 III 34 35 1" FCFvPn . 0 / A iT JA /0 34 35 36 1111 37 FAX 0 r / llr/ 0 0 AAIII / 0 0 l f / //� /f 36 37 1111 ... • �/ 0 f 0 f 38 i 39 40 41 • 0 r % , / / / �� 4 0 40 1111 41 42 PANEL NOTES: PHASE TOTALS 0A: 0 0B: 0 0C: 0 . ��� 0 0 . D 0 CONNECTED VA (CODE L) 0 CONNECTED VA (CODE R) 0 (CODE L) X 25% 0 42 PANEL NOTES: PHASE TOTALS 0A: 10248 06: 10248 0C: 10248 TOTAL CONNECTED VA 30744 CONNECTED VA (CODE N) 30744 CONNECTED VA (CODE L) 0 CONNECTED VA (CODE R) 0 (CODE L) X 25% 0 TOTAL -L° + TOTAL "N' 30744 PANEL DEMAND KVA 30.74 AMPS WITH /LCL 85.40 PANEL: P — L2 PANEL VOLTAGE 120/208 3 0 4 W CIRCUIT CODE: blank or N : NON — CONTINUOUS BUS: 200 AMP L : LONG — CONTINUOUS DAIS: 01/03/2007 TIME MAINS: MAIN BREAKER R : DEMANDABLE RECEPTACLES JOB: 6089 AIC RATING: 11,000 K : KITCHEN NO. OF EQUIPMENT: 0 z ,a ° 82 - -5 5/13 w ° LOA DESIGNATION C O N N E C T E D V A LOAD DESIGNATION (r W a° 32' z v 2 DESCRIPTION N R L 0 A 0 6 O C ABC OA O B O C N R L DESCRIPTION 1 can p ° . 'T ± + + + + + + ± ____ \\MEWL 0 I poo . ,on r + + - + + + + + - + + + + + + + + + Illi 1111 3 . �i7 r 0 r 4 5 mmh- =PEW M �" / / 0 1111/ 1111 / PRI • NW is 6 7 l ■ \ 0 0 8 9 0 J 1111 \ �� ., . \ IFf ‘ (2) 200A MC FEEDER CABLE (3) 250AL & (1) #4AL I A Ik. L ' ila 10 1111 11 MI + `r• fr " " "�� 0 r / /.� / 0 "" i/ ❑ + 7rfr 12 13 �1 rua + + C.J. + + + - + + + �1! �f —E�+4 Era P -LI 14 -r * + + + + + I- + 15 C.J. . C.J. C.J. / /.ff4/ 0 1111 + + + + + ± + + + 4- + + + 0 -H + I� + + + / + + 16 17 C.J. rrs 11=11 + + + + + _I + + ± - + + + + Nall /y0 0 0��%1111% 7 , f 0 '/' 0 x/1111 �JIJ///1111 0 ��O %1111 0 "" / 0 + + E.+ 18 19 l�lt I ;/ % /Z.All C.J D � Fry. 'A All A __ 20 1111 1111 1111 u11, 1111 21 + -I- --� ± ± + + + + C.J. I- `f- + + --H + f ' �til / 474 ��4/ j oi`a�� -• - ":drys: ° - -- ``". _ -__ ; -' -x - `,� - - :,:���' •.•_~ ry,;' Y fi � a, r,. • {Y �� ��Ii/ � �-.. -` `' 4 C.J. __ • E.J. 22 23 \ - ■ \ ^�\ ♦����� .. Ailx .♦♦��♦� . y►, C.J. + + + ■ I* - a1r ■ C.J. 111,,_ 4- ± + S A !.,.2 �� �, 0 II Affii + + ..- \„:134 + + + . ,, --- 4. ..;:z.A. �i;-��''�' �,j1� ■ 4- 11 wA . A, AL ■ A■ . dal ♦�■ A♦ ;.•�:�•�I -y Illi 24 25 IL 1Mil 11111111►Ilflllllll 0 rAAy 0 %/ °% 0 0 9fv _ _ 26 27 II III v 2rrArAr 0 L�.� 0 ! / �� �__..� 28 29 111 •_ �►7i■ %I�� ,,� , � ���S �4 . .. �- : _ - . 0 + EJ 30 31 E.J. . 0 ///' IN , r .111.11 ' . -� rA,. U W U - 32 33 W . / ff�7f47 111111111111.— J.. -_ % /� / //l III 34 35 1" FCFvPn . iT JA /0 36 1111 37 0 0 l f / //� /f 38 1111 39 • �/ 0 f 0 f 40 41 • / / / �� 4 0 - 42 PANEL NOTES: PHASE TOTALS 0A: 0 0B: 0 0C: 0 TOTAL CONNECTED VA 0 CONNECTED VA (CODE N) 0 CONNECTED VA (CODE L) 0 CONNECTED VA (CODE R) 0 (CODE L) X 25% 0 TOTAL "L" + TOTAL -N' 0 PANEL DEMAND KVA 0 AMPS WI1H/LCL 0 EXISTING 2000A 208/120V SWITCHBOARD 0 800A TAP CAN 0 0 0 0 0 0 O 0 200A MC FEEDER CABLE (3) #250AL & (I) #4AL 0 0 0 U 0 0 0 0 800A TAP CAN HOUSE PANEL 225A 120/208V EXISTING PANDA EXPRESS 200A 120/208V: P -LI PANDA EXPRESS 200A 120/208V P -L2 No chances shaU to ft s r. of work WfttiOtrt 2pp Tukwila Buii "4 NOTE: Revisions will requite a new par stibmittai and may include additional plan review fees, I REVIEWED FOR CODP�►70PNEG LIANCE NF JAN - 6 2008 City Of Tukwila „BIDDING DIVISION 01 M.E.P. FLOOR PLAN SITEA3.1 SCALE 1 /8 ° =1' -O' 001 00 . ••) r t LA PEI -MIT CENTER LANDLORD WORK PANDA EXPRESS SOUTHCENTER SQUARE BUILDING 'N' 17100 SOUTHCENTER PARKWAY TUKWILA, WA APPROVED PE. "�," � ";) (. f -Cr-in A Tln in CI wA Mto"'" 77 7! fA•GED, MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING 0717:AL, ALI WORK SHALL BE {TONE IN ACCORDANCE WITH THE APPROVED PLANS IS : "3.'L CT TO F;F'r 'NSPECTIor: REVISIONS REGISTRATION Public Works, euilding Division PERMIT NUMBER FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SIM 300 KIRKLAND, WA 98033 2KM DRAWN BY: DATE PROJECT NO.: PRINT DATE; DRAWING NAME: M.E.P.P.AN JZJ LH 06/21/07 A07 -409 01/03108 - 1:16pm A07 -409 BLDG N_A31_100.dwg '" immmon SHEET A3.1 Copyright 2007 Freiheit & Ho Architects, Inc., P.S. 14' ---8 1 /2" 82 - -5 5/13 32' -6 1/4" 32'- -6 1/4" 32' 6 1/4" OUTSIDE FACE OF PANEL J O U 0 0 U u_ O r FILE C • PIP / L Permit No. _ , :I , ,i Plar review approval Is subject to ema's and ornIsslont Approval of constructkvi documents does net mania the violation of any adopted code or ordnance. Recelp of approved Field con admovAedge E3 j U o-• SEPARATE PERMIT REQUIRED FOR: ritMechanical ❑ Electrical ��/ °lumbing LAG Gas Piping City of Tukwila BUILDING DIVISION Date :. /-10-' d a City of Tukwila BUILDING DIVISION n:tuil ¢ can p ° ° a . C.J. One moo 'T ± + + + + + + ± ____ \\MEWL 0 I poo . ,on r + + - + + + + + - + + + + + + + + + Illi 1111 �i7 mmh- =PEW M i, i cv i PRI • NW is l ■ \ / \ �� ., . \ IFf ‘ (2) 200A MC FEEDER CABLE (3) 250AL & (1) #4AL I A Ik. L ' ila IMPUB \ ArA4 :N I Lo MI + `r• fr () i/ ❑ + 7rfr �1 rua + + C.J. + + + - + + + �1! —E�+4 Era P -LI 1,3,5 �1/ -r * + + + + + I- + C.J. + + C.J. C.J. + + + + + ± + + + 4- + + + E.J. -H + I� + + + / + + ► • r ' AR Ak C.J. rrs 11=11 + + + + + _I + + ± - + + + + Nall C.J. C.J. + + E.+ 1 1' l�lt I ;/ % /Z.All C.J Fry. 'A All A __ 14' -2 1 /4" 3 _0" 37' -5" ,r; 1'i + -I- --� ± ± + + + + C.J. I- `f- + + --H + f ' �til i_ u -Y `�;:' : -.. -- - ;,f., ..we.nnsa oi`a�� -• - ":drys: ° - -- ``". _ -__ ; -' -x - `,� - - :,:���' •.•_~ ry,;' Y fi � a, r,. • {Y �� ��Ii/ � �-.. -` `' 4 C.J. __ • E.J. ± ± + + �• ti„fir , lei ..augliz A Iliki � \ - ■ \ ^�\ ♦����� .. Ailx .♦♦��♦� . y►, C.J. + + + ■ I* - a1r ■ C.J. 111,,_ 4- ± + S A !.,.2 �� �, II Affii + + ..- \„:134 + + + . ,, --- 4. ..;:z.A. �i;-��''�' �,j1� ■ 4- 11 wA . A, AL ■ A■ . dal ♦�■ A♦ ;.•�:�•�I -y Illi IL 1Mil 11111111►Ilflllllll _ II III E.J. L�.� �� �__..� 111 •_ �►7i■ %I�� ,,� , � ���S �4 . .. �- : _ - + EJ E.J. IIIII y t li1 � r�1 IN , r .111.11 ' . -� rA,. U W U - W U W U C.J. 111111111111.— J.. -_ 111111 + + + L � + + III 1" FCFvPn . iT JA OF TUKW I n 4 ?nnR 01 M.E.P. FLOOR PLAN SITEA3.1 SCALE 1 /8 ° =1' -O' 001 00 . ••) r t LA PEI -MIT CENTER LANDLORD WORK PANDA EXPRESS SOUTHCENTER SQUARE BUILDING 'N' 17100 SOUTHCENTER PARKWAY TUKWILA, WA APPROVED PE. "�," � ";) (. f -Cr-in A Tln in CI wA Mto"'" 77 7! fA•GED, MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING 0717:AL, ALI WORK SHALL BE {TONE IN ACCORDANCE WITH THE APPROVED PLANS IS : "3.'L CT TO F;F'r 'NSPECTIor: REVISIONS REGISTRATION Public Works, euilding Division PERMIT NUMBER FREIHEIT & HO ARCHITECTS, INC., P.S. 10230 NE POINTS DRIVE SIM 300 KIRKLAND, WA 98033 2KM DRAWN BY: DATE PROJECT NO.: PRINT DATE; DRAWING NAME: M.E.P.P.AN JZJ LH 06/21/07 A07 -409 01/03108 - 1:16pm A07 -409 BLDG N_A31_100.dwg '" immmon SHEET A3.1 Copyright 2007 Freiheit & Ho Architects, Inc., P.S.