Loading...
HomeMy WebLinkAboutPermit EL08-0015 - WESTFIELD SOUTHCENTER MALL - AEROPOSTALEAEROPOSTALE 2626 SOUTHCENTER MALL ELO8-015 Cityif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2626 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -015 Issue Date: 03/17/2008 Permit Expires On: 09/13/2008 Tenant: Name: AEROPOSTALE Address: 2626 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WEA SOUTHCENTER LLC Phone: Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: DAPHANE VOLTZ Phone: 412 - 243 -3430 X223 Address: LAMI GRUBB MANAGEMENT SERVICES , 100 SWISSVALE AVE Contractor: Name: STATIC ELECTRIC INC Address: PO BOX 972 , GRAHAM WA Contractor License No: STATIEI951C8 Phone: 253 468 -3296 Expiration Date: 02/25/2009 DESCRIPTION OF WORK: ELECTRICAL SYSTEMS FOR TENAMT IMPROVEMENT FOR NEW MALL SPACE Value of Electrical: $45,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $1,025.00 2005 Date: n ` V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of w• . . I . authorized to sign and obtain this electrical permit. Signature: Print Name: V v "' Q Date: _17.0U This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -015 Printed: 03 -17 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2626 SOUTHCENTER MALL TUKW Suite No: Tenant: AEROPOSTALE Permit Number: EL08 -015 Status: ISSUED Applied Date: 01/04/2008 Issue Date: 03/17/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: L./ Print Name: � & av1 scG Date: 3-/-7-023- ` 1 / -0 doc: Cond -Elec EL08 -015 Printed: 03 -17 -2008 w CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:llwww. ci. tukwila. wa. us Electrical Permit No. E - Project No. FO/b (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION !rye Co Assessor's Tax No.: (3Q) ti/ C � / 0 Site Address: Z u ...50c. ft `i7G�'ri te if M a (A., Suite Number ? t- CA2401 Floor:2� 3 Tenant Name: .Y0 r L Property Owners Name: ' 1 ' — Jar 1 L ' - 7-ena r7 (Oa' , l Yj a 70 i/ Mailing Address: 1)60/ Lu, /Sh L Y --e, I2 Aid , l till-410th/ 1-1. flnn-c k s CA 0621 Zip New Tenant: -�© Yes ❑ ..No City State CONTACT PERSON - Who do we contact when your permit is ready to be issued Name Q Mailing Address: j as L S\)Gt /--' ` 1 / -L t i s 'bur,5 h PA 5'4_6 E -Mail Address: d Vo L"t-t-- PC6mi_CjYt,t613 - cc(n C I M ay Telephone: (-11,. a4 3 - 343D Y 2_23 City State Fax Number: Li ) 2 - 3 7 /- /5$(pZtp ELECTRICAL CONTRACTOR INFORMATION Company Name: 1 0 b D le r n-zi ✓) e c/ - Wi .c r Up IC 6)c1 j Do pj- V. h.4 vj act iv_ Pcy Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ 1451 OD 0 / Scope of Work (please provide detailed information): ` h te‘ r + by- 7F'')G r') j r, tJ"( or e, C -)) S' 6 S 9C1 L (? 1 () G �')P �} S e (f o r) of G 7) ,P- �I,-S .1/ y- iT)a 4c(C(r /10✓1 Or / D1S- l a l t' -7-ts dk G b,- )(PJ /(P�'dot , / e Q� (� / v(Ir1 -4°r1 )v1 .efc. Gt • , r Will service be altered? ❑ Yes\] No Adding more than 50 amps? ■ Yes \❑ No Type of Use:Me Y( 01/7k.. Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ] Tenant Improvement --_�] ,Low , LowVoltage ❑ Generator Fire Alarm �f] Telecommunication .� orary Servic Property Served by: 04 I' ❑ Puget Sound Energy ❑ Seattle City Light H:Wpplications\Fonns- Applications On Line4-2007 - Electrical Permit Application.doc bh --1:A.)(1.110\ CAD/) 5 Page 1 of 2 J • RESIDENTIAL/ NEW RESIDENTIAL SERVIC ❑ New single family dwellings $140.00 (including an attac . garage) ❑ Garages, pools, s• and outbuildings $75.00 ea ❑ Low vol . systems furnace thermostat) S55.00 ea RESIDENTIAL REMODEL A ' i SERVICE CHANGES Service change or alteration $75.00 (no added/altered circu Service change with add -.a altered circuits $75.00 number o added circuits $10.00 ea Circuits added/alterrti without service change ts) (up to 5 circ $50.00 ❑ Circuits added/ r tered without service change $50.00 (6 or m' - circuits) $7.00 ea ❑ Meter /m.: repair $65.00 ❑ Low v tage systems $55.00 alarm, furnace thermostat) MULTI- FAMILY AND COMME CIAL Fees are based on the v ion of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outb ' i ing) ❑ Carnivals $75.00 Numb- . f concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: _ ) . - v Date: � • V Print NamePA1i ANf E-, \i Q L► Z — LA /Mt C-�- (Z U&) ADhtTSL.cfDay Telephone: Li.. / 2 ZU 3 - .31/44 3() X �-Z3 Mailing Address: ) Ca 6 -5Al a V/\ L AV ]1.&) i2 J F4 /52) 6 City State Zip IDate Application Accepted: v )�_ 0 g Date Application Expires: �-0 C Staff Initials: H:\Applications\Fotms- Applications On Line4-2007 - Electrical Permit Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -015 Address: 2626 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/04/2008 Applicant: AEROPOSTALE Issue Date: Receipt No.: R08 -00770 Payment Amount: $820.00 Initials: WER Payment Date: 03/17/2008 09:06 AM User ID: 1655 Balance: $0.00 Payee: STATIC ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 820.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 820.00 Total: $820.00 doc: Receipt -06 Printed: 03 -17 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -015 Address: 2626 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/04/2008 Applicant: AEROPOSTALE Issue Date: Receipt No.: R08 -00034 Initials: WER User ID: 1655 Payment Amount: $205.00 Payment Date: 01/04/2008 03:21 PM Balance: $820.00 Payee: LAMI GRUBB MANAGEMENT TRANSACTION LIST: Type Method Description Amount Payment Check 0499 205.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 205.00 Total: $205.00 6889 01/07 9710 TOTAL. 205.00 rinr. RA- j.int -OA Printari• 01- 04 -9lflR INSPECTION NO. INSPECTION RECORD Retain a copy with permit 11.6 - &fS PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: i��l�uf US-T1�LF Type of Inspection: 71Gv dye h j6 'NGrE -$(' gejle Date Called: Special Instructions: Date Wanted: .r./2-7 Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: f.000•"- Inspbr: 6LsalG Date:....././2 7/o $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 \(\ Pr• O ift 6. 779� �: Type of Inspection: #2/00 A yse m4 #w Date Called: Special Instructions: Date Wanted: Al Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: L / G c. IJ/f y ()(1 i9 /i Z. . n' 1,04U. / Al AVT11 V 12 IN( . V0��r�G .S 3- /r) /. /) EG /4.1 w"f4c i'iv CG/mirz •t ,rif inc- (-Ma i a Ir.'P)WA 61 G' /N / /Z., whit E f-X /'6�F(} /Ns jar 'Acv /7 / /.,fi ,or ,N S Insp air4/461//0 Date: .. //a/ tr 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 9 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr ect:^^�� / f�Mi'�C_� /-� Type of Inspection: Ad rests: �'?r'- � Date Called: /,2 " F 4�t Special Ins/ ctions: f .e..s Date Wanted: . / .S"! 2 0 a. Requester: SC- ,c/EAaLi� Phone No: DApproved per applicable codes. 1orrections required prior to approval. COMMENTS: 7) s77`'4, pic. rig/IL Le Ian /Ai /,2 " F 4�t ' C 1I16 ffk f .e..s � Af . eeivE 6 /x • 9 01A) C SC- ,c/EAaLi� nspe r: j� L eirre4406/1 Date /� 0 /0e, $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Projec 01V fi I- E Type of Inspection: 7003 Ad ` ,�/�A- ate Called: Special Instructions: Date Wanted: —/� m. Requester: Phone No: roved per applicable codes. Corrections required prior to approval. C(O/MMEENTS: /'/ /' //� % � ., —J' CF/ 4 ,�V' – 6 /la — �! - ten./ /c/ /L .A - ctiSe- j Inspe 1kf4&4V64' Date (//SAC( $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 II j�iCo /eJ ; G Type of Inspection: 7 003 "c4174 n, M Date Called: i Special Instructions: Date Wanted: a•�Y Requester: Phone No: proved per applicable codes. ❑ Corrections required prior to approval. OMMENTS: /0/1 L -- c ,' MM1X - /14 A SJ( ,,4'44 Ins pecr J// altlig4gi9,6# Date: /2 -/ } p $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspedion. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit FLO6 ^ Q/J Y' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Z. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro' c 'v ��sT G _ Type of Inspection: 7 ( )-. 7 Address ,ey�� `�� 2 2L . ((/!/7 e,G '�"S Abis Date Called: , Special Instructions: Date Wanted: ccI� J I = i� Requester: Phone No: pproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 109,. -c1/(4c 47164 /z 7// c- Inspec /lt Date: -ridor $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit PERMIT NO. 1p 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: / Type of Inspection: v � Address- 16 ,Oiii-iiCeeltratit Date Called: Special Instructions: Date Wanted: / I�' a.m. p.m. Requester: Phone No: roved per applicable codes. Corrections required prior to approval. f/9 kinZL■ L _c /9/E OMMENTS: Inspe 5 %LG AfitAfingo Date 10 # /of $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPE ION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: P 5 R� o p T Type of Inspection: 0 03 Address: 6 Vito— Date Called: Special Instructions: Date Wanted: q i I Cta,..rrei. Requester: q Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: R600 0.1A . - W .5 + t•ID5 - Uk�.S Ga,J.2JIT S 1∎1 - 1 1 Pt. -a 5-rco w 1l (Z$ ',4 Q oo \) Inspector: .11 Date: 0101/14 („ El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: - _._atiY¢.+ ILii -,e 't a`' ,AWAD INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a ropy with permit PERMIT NO. (206)431 -3670 Pr ect: tivutos ?�/ Type of Inspection: 7o , Addresses 2� Lf�+Z` itilL' Date Called: Special Instructions: /--4(F Date Wanted: ���� p.m. Requester: Phone No: Ef pproved per applicable codes. Corrections required prior to approval. EOMMENTS: ,..„A qd - f -t $ t2kf," /6..69vAl// % wtS7 /--4(F Inspec eill4X641/0/ Date: ,//‘ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 408- olrl PERMIT NO. (206)431 -3670 Project: E, OA) .57/ /1G4 Type of Inspection: 7oVl Address: Date Called: Special Instructions: Date Wanted: / iff II r� a. p.m. Requester. Phone No: Approved per applicable codes. COMMENTS: rrections required prior to approval. / 1 1 6 - / - 4 1 4 / c fo'i c-C ( 44th T /W)7 4moGiii /4) /U410 PAiwv ‘-//0 19cce,f,-(AK ml-)911, Insp9 /k.. figit4141/611 Date: 9' /i�D re El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: 1 C INSPECTION NO. INSPECTION RECORD Retain a copy with permit tt) ,0 oir PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Proiem© �4 Type of Inspection: _ 2 Address: , '1,91-1, Date Called: Special Instructions: Special Date Wanted: ��" P.m- Requester: . ? coNirlic 7-6/1 Phone No: 4011, ME/,rrl1N//�+TZ ; <:-; /1 2 �C/S/e` 2 c- 7 proved per applicable codes. Corrections required prior to approval. COMMENTS: pit9 OX— ThAlp .s- (/1C . ? coNirlic 7-6/1 c / {/cX CAN /445:. 4011, ME/,rrl1N//�+TZ ; <:-; /1 2 �C/S/e` 2 c- 7 Inspe 14t- 111,446,41/0 Date: i1c g J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: /3 2006 Washington State Nonresidential Energy Code Compliance Form Proje(t Summary 2006 Washington State Nonres dential Energy Code Compliance Forms PRJ -S011 ` Revised July 2007 Project Info Project Address Aeropostale # 979 -2626 Southcenter gall Date 12/31/2007 Tukwila, WA 98188 For Building Department Use Space # 2107 Applicant Name: Daphane Voltz - -Lami Grubb Management Services Applicant Address: loo E. Swissvale Ave Applicant Phone: Pittsburgh, PA 15218 ELO8Ot5 REVIEWED Pl1�ANCE CODE PA 70 - NEC JAN 1 7 2008 city of Tu a B.ILD D I FILE COPY JAN 0 4 2008 _ .TEr 2006 Washington State Nonresidential Energy Code Compliance Form intericir Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Aeropostale # 979 -2626 Southcenter Mall Date 12/31/2007 Tukwila, WA 98188 For Building Department Use Space # 2107 Applicant Name: Daphane Voltz - -Lauri Grubb Management Services Applicant Address: no E. Swissvale Ave Applicant Phone: Pittsburgh, PA 15218 Project Description ❑ Plans Included requirements. ❑ New Building ❑ Addition -, Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2" Area in ft2 Allowed x Area A Retail 1.50 3880.0 5820.0 B Retail Footnote #10 - a, b, c 1.50 2270.0 3405.0 c Adjustable Accent Light 4 90.0 360.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 9225.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed A Adjustable Accent Light 4 117.0 468.0 B Track Head 104 39.0 4056.0 c Adjustable Accent Light 4 90.0 360.0 F Fan / Light Combo 2 100.0 200.0 G Fluorescent Strip 9 58.0 522.0 J Fluorescent Strip 4 26.0 104.0 31 Fluorescent Strip 1 33.0 33.0 M Fluorescent Strip 26 41.0 1066.0 P Fluorescent Strip 8 33.0 264.0 N Fluorescent Strip 16 40.0 640.0 H Fluorescent Strip 32 33.0 1056.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 8769.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. JAN 04 2008 2006 Washington State Nonresidential Energy Code Compliance Form Inter & Lighting Summary (back 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools. hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishment?, restaurants /barss 1.3 Post office 1.1 Dormitory 1.0 Retail '', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia9, assembly spaces9 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hal13•4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory° shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only` Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (accesst�i�J� ggly,) , of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. WiPf l!'t U 2006 Washin.ton State Nonresidential Ener• Code Com•liance Form If "no" is circled for any question, provide explanation: JAN 04 2008 ►' 0 0 ., • � � T , � . r' - P - m' P 41TZ491MIIIIII teliy:1:1 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Aeropostale # 979 -2626 Southcenter Mall Date 12/31/2007 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations El yes 1513.2 Area controls Maximum limit per switch El n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls El 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 IMax. watts 'Indicate watts for each exit sign 1E1 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'Indicate size and efficiency I If "no" is circled for any question, provide explanation: JAN 04 2008 ial Energy Code Compliance Form lir lallig, Motor, and` Tr ansformer Permit Pla sCh cklist LTG CFiK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2- Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours- Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National ElectrtCa1 Manufacturers Association (NEMA TP -1- 2002). JAN 04 2008 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -015 DATE: 01 -04 -08 PROJECT NAME: AEROPOSTALE SITE ADDRESS: 2626 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTNils MENT I� B i Ing iion Public Works n Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: V Incomplete n DUE DATE: 01 -10-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R TING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved - Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02 -07-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License STATIEI951C8 Licensee Name STATIC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602455807 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 PO BOX 972 Address 2 City GRAHAM County PIERCE State WA Zip 98338 Phone 2534683296 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/25/2005 Expiration Date 2/25/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License JOHNSS *973PH Electrical Administrator Information License JOHNSS *973PH Name JOHNSON, SHANE Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date JOHNSON, SHANE E AGENT 02/28/2005 JOHNSON, SHANE E PRESIDENT 02/28/2005 1 Bond Information 1 i 1 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= STATIEI951 C8 03/17/2008 EGRESS DIAGRAM 3rd EXIT ROUTE: DISTANCE = 54' -0" MALL 0 0 r t m T I5t EXIT ROUTE: DISTANCE = 87' -0" ADJACENT TENANT �T _ Tr 1T Tr -IT C� I-- H— I- -� r r7 r� II' CJ �� LJ LJ 1-1-- (� C� - ►-- I-- ar�� 1r-7J 1L� 1L J1 2nd EXIT ROUTE: DISTANCE = 62' -0" EXITING: REQUIRED EXITS 2 FURNISHED EXITS 2 ADJACENT TENANT :. AEROPOSTALE ::E WES IELD SOUTHG Owol AEROPOSTALE STORE LOCATION SPACE #2101 3565 SQUARE FEET r� LEVEL 2 of 3 SEPARATE PERMIT REQUIRED FOR: rie Mechanical ❑ Electrical Plumbing Li Gas Piping City of Tukwila BUILDING DIVISION WESTFIELD SOUTHCENTER FILE COPY • 16.Permit Ha Plan review approval is Subject to amore and (missions. Approval of won downier* does not nabobsd the violation of any adopted code or ordnance. Receipt of approved Field Copy and is : By Date: 7, City of Tukwila BUILDING DIVISION SEATTLE, WA STORE #979 • of work vittout "fu J otn i" . NOTE: Revisions will require a new plan Subileal i may InClude adcf tiana! . GENERAL CONSTRUCTION NOTES L THE GENERAL CONTRACTOR (HEREIN AFTER CALLED THE G.G.) IS TO VISIT THE SITE PRIOR TO SUBMITTING A BID TO VERIFY EXISTING CONDITIONS. 2. G.C. 15 TO VERIFY LEASE SPACE DIMENSIONS AND EXISTING BUILDING ELEMENTS FOR COMPLIANCE WITH THE DRAWINGS. NOTIFY THE OWNER AND ARCHITECT FOR RESOLUTION OF DIMENSIONAL CONFLICTS IF EXISTING. NO CHANGE ORDERS WILL BE ISSUED FOR CHANGES REQUIRED IN THE WORK AFTER CONSTRUCTION HAS COMMENCED UNLESS SPECIFICALLY AUTHORIZED BY THE OWNER. 3. ANY DISCREPANCIES, ERRORS, OR OMISSIONS DISCOVERED IN THE CONTRACT DOCUMENTS BY THE CONTRACTOR SHALL 13E BROUGHT TO THE ATTENTION OF THE OWNER AND LAMI GRUBB BEFORE PROCEEDING WITH RELATED WORK. OTHERWISE, THE CORRECTION OF SUCH ITEMS WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 4. THE G.G. SHALL MEET WITH AN AUTHORIZED REPRESENTATIVE OF THE LANDLORD TO REVIEW CONSTRUCTION PROCEDURES. G.G. SHALL COORDINATE WORK WITH THE LANDLORD WITH REGARD TO TEMPORARY BARRICADES, UTILITIES, ALLOWABLE MATERIALS, TRAFFIC ROUTES, DELIVERY LOCATIONS AND METHODS, STORAGE OF MATERIALS AND TOOLS, NOISE, DUST CONTROL, REQUIRED DEPOSITS, REQUIRED CONTRACTORS, GLEAN -UP, AND ALL OTHER MATTERS REQUIRING ADHERENCE TO LANDLORD REQUIREMENTS. 5. APPLICABLE STANDARDS OF THE CONSTRUCTION INDUSTRY HAVE THE SAME FORGE AND EFFECT ON PERFORMANCE OF THE WORK AS IF COPIED DIRECTLY INTO CONTRACT DOCUMENTS OR BOUND AND PUBLISHED HEREWITH. COMPLY WITH STANDARDS IN EFFECT AS OF THE DATE OF CONTRACT DOCUMENTS, UNLESS OTHERWISE INDICATED. 6. THE G.G. 15 RESPONSIBLE TO RECEIVE, COUNT AND VERIFY ALL OWNER FURNISHED ITEMS AT THE JOB SITE, INCLUDING, BUT NOT LIMITED TO: FREE - STANDING FIXTURES, PERIMETER FIXTURES, FLOORING, BASE, GLAZING CHANNEL, CASEWORK ITEMS, LIGHTING, LAMPS, GRAPHIC, BOXES, AND FITTING ROOM COMPONENTS. 1 EXCEPT AS OTHERWISE INDICATED, THE G.C. IS TO FURNISH ALL MATERIALS, LABOR AND EQUIPMENT. FOR THE COMPLETE AND SATISFACTORY EXECUTION OF THE CONTRACT WORK AS SHOWN, GALLED FOR, EXPRESSED OR REASONABLY IMPLIED BY THE CONTRACT DOCUMENTS IN COMPLIANCE WITH CODES AND REGULATIONS OF ALL NATIONAL, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. ARCHITECT CORTLAND MORGAN 111 N. FIELDER ROAD ARLINGTON, TX 76012 PHONE: SI1- 635 -5616 FAX: 517- 635 -5611 PROJECT MANAGER DAPHANE VOLTZ LAMI GRUBB MANAGEMENT SERVICES 100 EAST SWISSVALE AVENUE PITTSBURGH, PA 15215 PHONE: 412- 243 -3430 FAX: 412 - 311 -1556 ENGINEER HALLBERG ENGINEERING 1150 COMMERCE COURT WHITE BEAR LAKE, MN 55110 PHONE: 651-14E3-1100 FAX: 651 -145 -1370 ''''.94/14eLsiThoo"Nese"*Ne"—N, JONATHAN RAaDLOVE PROJECT MANAGER PHONE: 115-526-1 110 d MICHAEL BOV N o CONSTRUCTION MANAGER PHONE: 173 - 512 -4157 4 TIM ANDERSON $ VICE PRESIDENT OF CONSTRUCTION PHONE: 173- 526 -1421 AEROPOSTALE 201 WILLOWBROOK BLVD. 4 1th FLOOR WAYNE, NJ 01470 4 OP - — - REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JAN 1 7 208 Cry Of Tukwila ILDIN: D ISN TENANT COORDINATOR JOSHUA KIMMEL WESTFIELD CORP., INC. 11601 WILSHIRE BLVD, I4TH FLOOR LOS ANGELES, GA 10025 PHONE: 3I0- 513 -4761 FAX: 310 -515 -5111 MALL OPS. MGR. ANDY GIARROCGHI WESTFIELD SOUTHCENTER 633 SOUTHGENTER PARKWAY TUKWILA, WA 15155 PHONE: 206- 246 -0423 BUILDING DEPT. BUILDING DIVISION CITY OF TUKWILA 6300 SOUTHCENTER BLVD SUITE 100 TUKWILA, WA 15155 PHONE: 206 - 431 --3670 /N LEVEL PRIOR TO PROCEEDING WITH WORK. LLD NOTES L ALL COLOR AND MATERIAL SELECTIONS MUST MEET ALL CODE REQUIREMENTS FOR FLAME SPREAD AND SMOKE DEVELOPMENT FACTORS. 2. VERIFY AT JOBSITE CLEARANCE OF EXISTING BRACING AT REAR DOOR. 3. DOOR BELL TO SE INSTALLED AT 3' -6" A.F.F. 4. TENANT'S CONTRACTOR TO GET APPROVAL AND GORING REQUIREMENTS ON UPPER LEVEL PRIOR TO PROCEEDING WITH WORK. 5. TENANT SHALL PROPERLY SEAL ALL PENETRATIONS TO COMPLY WITH GORE REQUIREMENTS. THE FIRE RATED ASSEMBLY SHALL BE MAINTAINED. ALL PLUMBING, ELECTRICAL, AND MECHANICAL DEVICES PENETRATING THE FLOOR SHALL BE FIRE RATED. 6. WATER PROOF MEMBRANE MUST BE INSTALLED UNDER CERAMIC TILE IN TOILET ROOMS A MINIMUM OF 4" UP WALLS. TENANT REQUIRED TO INSTALL LANDLORD APPROVED LATEX RUBBER WATERPROOFING MATERIAL. MEMBRANE SHALL BE MANUFACTURER'S 2-PART FORMULA CONSISTING OF LIQUID LATEX RUBBER AND POWDER FOR TROWEL APPLICATION WITH GLASS FIBER FABRIC REINFORCEMENT (LATICRETE 1235 OR SUMMITVILLE S- 1000). INSTALL A WATER TIGHT DOOR THRESHOLD, 1 ALL SUPPORTS TO BE FROM STRUCTURAL BEAMS AND JOISTS. NO CONNECTING TO DECK ALLOWED. S. STOREFRONT MUST BE INDEPENDENTLY SUPPORTED. LANDLORD'S BULKHEAD GAN ONLY BE USED FOR LATERAL SUPPORT. `'��� . .L ..ice 1 1 j.. L CODE INFORMATION USE GROUP: M - MERCANTILE APPLICABLE CODES: CONSTRUCTION TYPE: 2B 2006 INTERNATIONAL BUILDING CODE W/ AMENDMENTS FULLY SPRINKLED: YES 2006 INTERNATIONAL MECHANICAL CODE OCCUPANCY CALCULATION: 2006 NATIONAL ELEGTRIG CODE PLUMBING CODE 2006 UNIFORM TOTAL SQUARE FOOTAGE = 3865 2006 INTERNATIONAL FIRE CODE SALES AREA: 2003 ANSI 1111 ACCESSIBILITY GUIDELINES 2181 SF / 30 SF per person = 100 2003 NON- RESIDENTIAL ENERGY CODE NON -SALES AREA: PREVAILING LOCAL AMENDMENTS 581 SF / 300 SF per person = 3 TOTAL OCCUPANT LOAD = 103 DESCRIPTION OF PROJECT: ' AEROPOSTALE' RETAIL CLOTHING STORE TENANT FIT -OUT OF A NEW DEMISED SPACE; NEW ADDITION TO AN EXISTING COVERED 3 STORY MALL (SHELL PERMIT D06 -I41) DRAWING INDEX e ISSUE REVISION F R '1' LANDLORD PERMIT GS COVER SI -}EET 11/23/07 12/27/07 151 SCHEDULES AND VENDOR LIST 11/23/07 12/27/07 Al CONSTRUCTION PLAN 11/23/07 12/27/07 A2 FIXTURE PLAN $ DETAILS 11/23/07 12/27/07 A5 FLOOR COVERING PLAN 11/23/07 12/27/07 A4 REFLECTED CEILING PLAN $ DETAILS 11/23/07 12/27/07 AS LIGHTING PLAN 4 DETAILS 11/23/07 12/27/07 A6 STOREFRONT FLAN, ELEVATION 4 DETAILS 11/23/07 12/27/07 Al STOREFRONT SECTIONS 4 DETAILS 11/23/07 12/27/07 AS INTERIOR ELEVATIONS 11/23/07 12/27/07 Al DETAILS 11/23/07 12/27/07 Alo DETAILS 11/23/07 12/27/07 SGI SIGN DETAILS 11/23/07 12/27/07 MO MECHANICAL TITLE SHEET 11/21/07 12/10/07 MI HVAC PLAN 11/21/07 12/10/07 M2 PLUMBING PLAN 11/21/07 12/10/07 MS MECHANICAL SPECIFICATIONS 11/21/07 12/10/07 EC ELECTRICAL TITLE SHEET $ PANEL SCHEDULES 11/21/07 12/10/07 El LIGHTING PLAN 11/21/07 12/10/07 E2 POWER PLAN 11/21/07 12/10/07 ES ELECTRICAL DETAILS 11/21/07 12/10/07 E4 ELECTRICAL SPECIFICATIONS 11/21/07 12/10/07 SI GENERAL STRUCTURAL $ DETAILS 12/13/07 52 SUSPENDED CEILING DETAILS 12/13/07 APPROVED PP. •1r ".;:D nrEc rCArioms Pa t.'7727 Ci :A." GED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING or._Ic :AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS 3:,'3.;E ;T TO FIELD INSPECTIONS DATE: 11/23/01 JOB NO: 01193 DRAWN: CHECKED: 1 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 co Coordination 0 0 0 „As rn AND MORG AYE O1 WASHING REVISIONS REVISION I Public Works, Building Division PERMIT NUMBER ELoB 015 'ED "off U 4 2008 • kiTnM COVER =, SHEET NUMBER FILE COPY 0-1Ig3 -Al- q -REV I- 122601dwg.dvag 12/27/07 1 d z 0 z d December 21 , 2001 -11:20 am PRINT DATE $ TIME BALANCE PHASE LOADS TO WITHIN 10% OF EACH OTHER. ( *) INDICATES BREAKER TO BE LOCKED ON. PANEL LA ELECTRICAL SYMBOLS A.I.C. 10,000 LIGHT FIXTURE DESCRIPTION MOUNTING WIRING DEVICE DESCRIPTION MOUNTING COMMUNICATIONS DESCRIPTION MOUNTING KVA SURFACE FLUORESCENT, NORMAL POWER SURFACE FLUORESCENT, EMERGENCY POWER RECESSED FLUORESCENT, NORMAL POWER RECESSED FLUORESCENT, EMERGENCY POWER WALL MOUNTED EXIT SIGN, SHADING 96" INDICATES THE ILLUMINATED FACES or 8" BFC CEILING MOUNTED EXIT SIGN, SHADING INDICATES THE ILLUMINATED FACES BATTERY PACK, NORMAL POWER or 8" A BFC BATTERY PACK, EMERGENCY POWER o or r B 8" BFC POLE, BASE AND FIXTURE(S). CIRCLES INDICATE # OF HEADS PER POLE, NORMAL POWER POLE, BASE AND FIXTURE(S). CIRCLES INDICATE # OF HEADS PER POLE, EMERGENCY POWER WALL MOUNTED FIXTURE AND BRACKET, NORMAL POWER WALL MOUNTED FIXTURE AND BRACKET, EMERGENCY POWER STRIP FIXTURE, NORMAL POWER STRIP FIXTURE, EMERGENCY POWER SURFACE MOUNTED DOWNLIGHT, NORMAL POWER SURFACE MOUNTED DOWNUGHT, EMERGENCY POWER RECESSED DOWNLIGHT, NORMAL POWER RECESSED DOWNLIGHT, EMERGENCY POWER RECESSED WALL WASHER, NORMAL POWER RECESSED WALL WASHER, EMERGENCY POWER TRACK FIXTURES AND TRACK ASSEMBLY, NORMAL POWER TRACK FIXTURES AND TRACK ASSEMBLY, EMERGENCY POWER OWITCH, WHERE "X " CAN BE 46" ONE OF THE FOLLOWING: 2 = DOUBLE POLE 3 = THREE WAY 4 = FOUR WAY K = KEYED LV = LOW VOLTAGE MC = MOMENTARY WITH RTC OS = OCCUPANCY SENSOR (blank) = SINGLE POLE DIMMER SWITCH, OPERATING 46" WATTAGE INDICATED SWITCH WITH PILOT LIGHT 46" OCCUPANCY SENSOR, WHERE "Y" IS THE RATED AREA OF COVERAGE AND "X" IS ONE OF THE FOLLOWING: DT = DUAL TECHNOLOGY US = ULTRASONIC PIR = PASSIVE INFRARED Main: MLO 225A RECEPTACLE OPTIONS DENOTED BY "X", WHERE "X" CAN BE ONE OF THE FOLLOWING: IG = ISOLATED GROUND GFI = GROUND FAULT INTERRUPTER TR = TAMPER RESISTANT SS = SURGE SUPPRESSOR WP = WEATHERPROOF (blank) = STANDARD RECEPTACLE SIMPLEX RECEPTACLE, NORMAL POWER DUPLEX RECEPTACLE, NORMAL POWER DUPLEX RECEPTACLE, UPS POWER DUPLEX RECEPTACLE, EMERGENCY POWER FOURPLEX RECEPTACLE FLOOR OUTLET BOX, POWER, VOICE AND /OR DATA SPECIAL PURPOSE RECEPTACLE, WITH NEMA CONFIGURATION NOTED MULTIOUTLET ASSEMBLY, REFER TO SPEC 18" 18" 18" 18" 18" 18" 54" 54" K INTERCOM - DESK 18" I4 w INTERCOM - WALL 54" I® TELEPHONE - DESK 18" 1.4 w TELEPHONE - WALL 54" 4 H HOUSE PHONE 54" IA VOICE /DATA OUTLET 18" 1 GY Ortu UOUTLET (REFER TO SPEC.) 18" CO BELL 80" IFD" BUZZER 80" CHIME 80" TELEVISION RECEIVER 18" F'lM MICROPHONE OUTLET 18" LINE LEVEL OUTLET 18" I-[]c ' VOLUME CONTROL, ZONE 46" 1 NUMBER INDICATED FEI P PROJECTOR OUTLET 18" Es I-© EFFECTS SPEAKER OUTLET RC REMOTE CONTROL M5 FE MONITOR SPEAKER OUTLET 5R I� SOUND REINFORCEMENT OUTLET 6" BFC Ar ®1 SPEAKER, CEILING MOUNTED WITH TYPE AND ZONE NUMBER INDICATED (REFER TO SPECIFICATION FOR TYPE) ®AT SPEAKER, WALL MOUNTED WITH TYPE AND ZONE NUMBER INDICATED (REFER TO SPECIFICATION FOR TYPE) 1 ©41 SPEAKER RE- ENTRANT HORN WITH ZONE NUMBER INDICATED ■0. CB NO. HL 0 B Irr: I- ® '-P x ©X x li)x Mxx 0 Ed 0-30R PS -A AMIN d • 0. 0 • FO . -111.- D EJ f' ^ MS f� MSS ° FOR TYPE AND RECEPTACLE SPACING DISCONNECT SWITCH, NON -FUSED DISCONNECT SWITCH, FUSED MOTOR STARTER SWITCH WITHOUT OVERLOAD PROTECTION MOTOR STARTER SWITCH WITH OVERLOAD PROTECTION MAGNETIC MOTOR STARTER WITH EQUIPMENT NUMBER INDICATED COMBINATION MOTOR STARTER AND FUSED DISCONNECT WITH EQUIPMENT NUMBER INDICATED EQUIPMENT TAG (REFER TO EQUIPMENT SCHEDULE) 208/120 VOLT PANELBOARD 480 /277 VOLT PANELBOARD TERMINAL CABINET ANNUNCIATOR PANEL 9.3 45/3 0 S 0 a -0 _0 7 Q I� EF -1 Nr EF -1 EH AHU 1 7' i� FIRE ALARM DESCRIPTION MOUNTING • V X "X" 4 FIRE ALARM DEVICE, WHERE CAN BE 1 X u.) ONE OF THE FOLLOWING: (blank) FIRE ALARM MANUAL PULL STATION 46" ( K FIRE ALARM MANUAL KEYED STATION 46" I IONIZATION DETECTOR H THERMAL DETECTOR P PHOTOELECTRIC SMOKE DETECTOR DS DUCT SMOKE DETECTOR FL SPRINKLER VALVE FLOW SWITCH B -T BEAM DETECTOR, TRANSMITTER B -R BEAM DETECTOR, RECEIVER RB ROTATING BEACON MM MONITOR MODULE CM CONTROL MODULE D MAGNETIC DOOR HOLDER MR SHUTTER /ROLLING DOOR RELEASE TS DUCT DETECTOR REMOTE TEST STATION 80" VDT VIDEO DISPLAY TERMINAL & KEYBOARD PR SYSTEM EVENT PRINTER F • FIRE ALARM HORN 80" F • FIRE ALARM SPEAKER 80" F • FIRE ALARM STROBE 80" • F ■ FIRE ALARM HORN WITH STROBE 80" • MH F • FIRE ALARM MINI -HORN WITH STROBE 80" • F A FIRE ALARM SPEAKER WITH STROBE 80" I® F FIREFIGHTER PHONE JACK 46" F FIRE ALARM BELL 80" FIRE ALARM CHIME 80" HS FIRE ALARM CHIME WITH STROBE 80" IDX SPRINKLER VALVE POSITION SWITCH oow HD MISCELLANEOUS DESCRIPTION MOUNTING O I-© © FE I- EPO H Fill JUNCTION BOX, RECESSED WALL JUNCTION BOX, RECESSED CEILING CLOCK, WALL MOUNTED 96" or 8 BFC CLOCK, CEILING MOUNTED LINE VOLTAGE THERMOSTAT 58" PUSHBUTTON 46" EMERGENCY POWER OFF PUSHBUTTON 46" TIME SWITCH CONTACTOR I X X E Y Y BRANCH CIRCUITING 6 9.9 SPARE LP PANEL NAME TRACK LIGHTING DESIGN PRESENTATION DESCRIPTION -1 -1 - 20/1 O 1 Al i - - ~ . KEY NOTE, REFER TO LIST OF KEY NOTES ON THE SAME PLAN FEEDER NOTE, REFER TO FEEDER SCHEDULE ON THE SAME PLAN DRAWING REVISION NOTE CONCEALED RACEWAY RACEWAY INSTALLED IN FLOOR OR BELOW FINISHED GRADE RACEWAY RACEWAY UP RACEWAY DOWN CONDUIT STUB, BUSHED AND CAPPED UNDERFLOOR DUCT, POWER AND COMMUNICATIONS RACEWAYS 1,3,5 - CIRCUIT NUMBER(S) GROUND CONDUCTOR / /� NEUTRAL CONDUCTOR PHASE CONDUCTORS 3/4' N. CONDUIT AND WIRE SIZE (1/2" C, 2 #12, UNLESS NOTED OTHERWISE) LIGHT FIXTURE DESIGNATOR, REFER TO LIGHT A-----FIXTURE JFIXTURE SCHEDULE FOR TYPE AND VOLTAGE * 0 ,-i �� 1.2 CIRCUIT NUMBER SWITCH LEG ELECTRICAL SHEET INDEX EO ELECTRICAL TITLE SHEET & PANEL SCHEDULES El LIGHTING PLAN E2 POWER PLAN E3 ELECTRICAL DETAILS E4 ELECTRICAL SPECIFICATIONS L� -- BALANCE PHASE LOADS TO WITHIN 10% OF EACH OTHER. ( *) INDICATES BREAKER TO BE LOCKED ON. PANEL LA PANEL HA A.I.C. 10,000 Location: Stockroom Mounting: Surface A.I.C. 14,000 # 480/277 Volt, 30, 4w KVA Mounting: Surface NO. Main: MLO 225A A Circuit Description C KVA CB NO. HL A B C HL NO. CB KVA Circuit Description 27.9 VAV -1 2 9.3 45/3 1 * X 20/1 3 * 2 70/3 13.0 45 KVA TRANSFORMER 4 9.3 9.3 3 TRACK LIGHTING X 0.7 - 4 13.8 5 X 6 9.9 SPARE 1.8 TRACK LIGHTING 20/1 7 20/1 X X 8 * 8 SPACE 1.2 IWH -1 PERIMETER LIGHTING 8.3 40/1 9 X 10 20/1 1.2 SPACE FITTING ROOM LIGHTING IWH -2 20/1 8.3 40/1 11 X X 20/1 12 TRACK LIGHTING CASH WRAP LIGHTING SPACE 20/1 SPACE * X 20/1 13 X 20/1 1.8 TRACK LIGHTING 14 0.8 20/1 SPACE SPACE X 20/1 15 20/1 1.8 X SPARE 0.6 16 17 SPACE SPACE 18 20/1 17 TRACK LIGHTING SPARE 0.6 X 19 18 X SPACE * CONNECTED KVA: CONNECTED AMPS: 81.2 113.4 A 22.3 B 31.4 C 27.5 ■ DESIGN DEMAND KVA: DESIGN DEMAND AMPS: 78.0 93.9 21 BALANCE PHASE LOADS TO WITHIN 10% OF EACH OTHER. ( *) INDICATES BREAKER TO BE LOCKED ON. PANEL LA Location: Stockroom A.I.C. 10,000 208/120 Volt, 30, 4w Mounting: Surface Main: MCB 150A Circuit Description KVA CB NO. HL A B C HL NO. CB KVA Circuit Description EXIT /EM /NL 0.4 20/1 1 * X HVAC 27.9 * 2 20/1 1.2 SIGN STOREFRONT LIGHTING 0.5 20/1 3 78.0 X 97.7 * 4 20/1 t8 TRACK LIGHTING PERIMETER LIGHTING 0.7 20/1 5 X 6 20/1 1.8 TRACK LIGHTING PERIMETER LIGHTING 0.7 20/1 7 X * 8 20/1 1.2 TRACK LIGHTING PERIMETER LIGHTING 0.8 20/1 9 X 10 20/1 1.2 TRACK LIGHTING FITTING ROOM LIGHTING 0.2 20/1 11 X 12 20/1 1.8 TRACK LIGHTING CASH WRAP LIGHTING 0.4 20/1 13 * X 14 20/1 1.8 TRACK LIGHTING REAR COVE LIGHTING 0.8 20/1 15 X 16 20/1 1.8 TRACK LIGHTING SPARE 0.6 20/1 17 X 18 20/1 1.5 TRACK LIGHTING SPARE 0.6 20/1 19 * X * 20 20/1 1.2 TRACK LIGHTING TOILET LTG /FAN 0.4 20/1 21 X 22 20/1 1.2 TRACK LIGHTING STOCKROOM LIGHTING 0.6 20/1 23 * X 24 20/1 0.2 SPARE SPACE 0.1 20/1 25 X 26 20/1 1.3 SPACE SPACE 0.2 20/1 27 X 28 20/1 0.7 SPACE SPACE 20/1 29 X 30 20/1 0.7 SPACE SPACE 1.5 20/1 31 * X 32 20/1 SPACE SPACE 20/1 33 X 34 20/1 SPACE SPACE 20/1 35 X 36 SPACE PANEL LB 6.1 100/3 37 * X 38 SPACE 5.3 39 X 40 SPACE 3.3 41 SPACE SPACE X 42 SPACE CONNECTED KVA: 36.7 CONNECTED AMPS: 115.0 A 13.0 B 13.8 C 9.9 DESIGN DEMAND KVA: 36.3 DESIGN DEMAND AMPS: 100.8 SPACE BALANCE PHASE LOADS TO WITHIN 10% OF EACH OTHER. ( *) INDICATES BREAKER TO BE LOCKED ON. PANEL LB Location: Stockroom A.I.C. 10, 000 208/120 Volt, 30, 4w Mounting: Surface Main: MLO 125A Circuit Description KVA CB NO. HL A B C HL NO. CB KVA Circuit Description BACK WRAP RECEPTACLES 0.4 20/1 1 1.0 X HVAC 27.9 * 2 20/1 0.4 CASH REGISTER SALES RECEPTACLES 0.8 20/1 3 78.0 X 97.7 * 4 20/1 0.4 CASH REGISTER SALES RECEPTACLES 0.8 20/1 5 X 6 20/1 0.4 CASH REGISTER SPARE 20/1 7 X * 8 20/1 0.4 CASH REGISTER SHOW WINDOW RECEPTACLES 0.2 20/1 9 X 10 20/1 0.4 CASH REGISTER (SEASONAL) SHOW WINDOW RECEPTACLES 0.2 20/1 11 X 12 20/1 0.4 CASH REGISTER (SEASONAL) MANAGER'S DESK 0.8 20/1 13 * X 14 20/1 0.4 CASH WRAP RECEPTACLES MANAGER'S DESK 0.8 20/1 15 X 16 20/1 0.8 CASH WRAP RECEPTACLES h STOCKROOM RECEPTACLES 0.6 20/1 17 X 18 20/1 SPARE q; WATER COOLER 0.6 20/1 19 * X * 20 20/1 0.2 SECURITY TOILET RECEPTACLES 0.4 20/1 21 X 22 20/1 0.6 FITTING ROOM DOORS SPARE 20/1 23 X 24 20/1 0.2 STOREFRONT GRAPHIC BOXES TIME CLOCK 0.1 20/1 25 X 26 20/1 1.3 BACK WRAP GRAPHIC BOX PHONE BOARD 0.2 20/1 27 X 28 20/1 0.7 PERIMETER GRAPHIC BOX SPARE 20/1 29 X 30 20/1 0.7 PERIMETER GRAPHIC BOX REFRIGERATOR / MICROWAVE 1.5 20/1 31 * X 32 20/1 SPARE SPARE 20/1 33 X 34 20/1 SPARE SPARE 20/1 35 X 36 SPACE SPACE 37 X 38 SPACE SPACE 39 X 40 SPACE SPACE 41 X u 42 SPACE CONNECTED KVA: 14.7 CONNECTED AMPS: 50.8 A 6.1 B 5.3 C 3.3 DESIGN DEMAND KVA: 14.6 DESIGN DEMAND AMPS: 40.4 BALANCE PHASE LOADS TO WITHIN 10% OF EACH OTHER. ( *) INDICATES BREAKER TO BE LOCKED ON. LOAD SUMMARY CONNECTED KVA DESIGN FACTOR DESIGN DEMAND KVA LIGHTING 8.4 0.95 8.0 TRACK LIGHTING 15.3 1.0 15.3 RECEPTACLES 5.8 1.0 5.8 SIGN 1.2 1.0 1.2 WATER HEATER 16.6 1.0 16.6 HVAC 27.9 0.9 25.1 MISCELLANEOUS 6.0 1.0 6.0 TOTAL KVA: 81.2 78.0 TOTAL AMPS: 97.7 93.9 SERVICE KVA: 78.0 1.25 97.5 SERVICE AMPS: 117.3 CRDEWED FOR NFpCOMP LIANCE NEC JAN 1 , 2088 B city Of Tukwil ILO. NG D . a LOBOl5 DATE: 11/21/01 JOB NO: 01- 3201.62 DRAWN: DJQ CHECKED: ILLS /JRP 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 Project Coordination 00 fDL CO r Q 12 CO J N AFF wWQ LL1 U(f) LJ d 0 �y (o uJ ( d �iJ (J 1 HALLBERG ENGINEERING Mechanical /Electrical Consulting Engineers 1750 Commerce Court, White Bear Lake, MN 55110 (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS JAN 0 4 2008 Per <M ! (.;ENTER SHEET NUMBER ELECTRICAL ma SHEET & DETAILS EO R L A LA-23 P W1 LA -23 G LA -23 G LA -23 W1 _4 -21 4W1 LA -21 F LA -2 ral W LA -23 G A -2 LA -23 G LA -23 w1 , LA -23 T 7i LB L_ G G LA -23 —7b M LA -7 • bk=51 J LA -11 H_ J LA-1 1 J1 LA -11 J LA -11 LA-5- J LA -11 W1 A- L H LA -5 N -7 H LA 5 L 0 H LA -5 M LA -7 M LA -7 1 M LA -7 I i 1 H LA -5 ' D 1 H LA -5 T T LA -5 1 1 B(3) LA -20 H LA -15 B 3) LA -20 H LA -5 M LA -15 M LA -15 W2 ❑ LA -1 / A 18 3 H NL -1 H -LA-5 I L H A5 1 � M LA -7 1 M LA -7 L • 1 H LA -15 • ..H LA -5 0 �L H LA -1 C\ B(3) LA -14 0 I�• 16' D H b-'t5 8' 6 B(3) LA -22 B(8) LA -1 _A -13 [ C A -13 C LA -13 LA-16 6 0 $' 9 NIA) LA -9 1 1 LA -9 M LA -7 M LA -7 -/�/A /e /e /e/e/e /e/e/e �rxr�coLC�acxra� AAA' • 7 L Q \ B(5) LA -14 P LA- 3 LA- 3 P LA-- 3 P LA -13 P LA--3 P LA -13 P LA -' 3 P LAS 3 8r I• W2 LA -1 ❑ W2 LA -1 12' Q S' 9 9 9 6 12' 9 B(5) LA -16 a 9 9 B(5) LA -12 9 3(5) LA -12 B(5) LA -14 Nom) LA -9 DATE: 11/21 /01 JOB NO: 01- 3201.62 DRAWN: 17.4 CHECKED: KLS /JRP 8'0 9 9 6 B(5) LA -8 8' Q 0 a 8' 9 c 0 9 9 0 Q \ B(5) LA -16 77r771277- 7777 rn.7rr77/77 ', ,7,7rmrrnrrA7JrrA 9 i /rur /rur /r/u 1.0 ..*V/ je /ii /e/u/ -I AV .//r7 ..CAT♦ M LA -7 GYP. BD. CEILING SUSPENSION SYSTEM • SURFACE MOUNTED LIGHTING TRACK. MOUNTED TO GYP. BD. CEILING WITH TOGGLE BOLTS, SEE LIGHTING DRAWINGS FOR MORE INFORMATION TRACK LIGHT FIXTURE PAINTED GYP. BD. CEILING TRACK HANGING DETAIL :ID NTS LIGHTING PLAN 1/4" = 1' -0" M LA -7 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 0 W2 LA -1 $' 9 9 U 0 0 L 0 B(5) LA -10 M LA-9 NOTE: PER GOVERNING CODE, FURNISH AND INSTALL SELF CONTAINED BATTERY PACK EMERGENCY LIGHTING THROUGHOUT THE DEMISED PREMISES INCLUDING THE TOILET ROOMS. STOREFRONT SIGNAGE AND LIGHTING TIME CLOCKS SHALL BE SET TO MALL'S OPERATING HOURS. TENANT SHALL INSTALL RECESSED LIGHTING IN CEILING AND DOOR BELL LOCATED AT 3' -6" ABOVE FINISHED FLOOR AT TENANT REAR ACCESS DOOR ALCOVE. NL LA -5 1 I 1 1 1 M LA -7 H -LA- -5 M LA -7 [3 #/!O1//,tl4 R'VE 1 POoTG/JtAL0 /L /9-7-- F4-002 A-604iG 7-7)1E oediriRs 46/C4 /9-A b.[sc-i-/-4-4.6F GENERAL NOTES A. B. �41.fifid42 ®oi2/w, Y ELECTRICAL CONTRACTOR TO REFER TO ARCHITECTURAL DRAWINGS FOR ALL LIGHT FIXTURE LOCATIONS. CONTRACTOR SHALL COMPLETELY REMOVE ALL EQUIPMENT, PANELBOARDS, DEVICES, FIXTURES, WIRING, CONDUIT, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. KEY NOTES OPROVIDE J -BOX AND WHIP FOR STORE SIGN. SIGN UL #E68384. SEE SPECIFICATIONS ON SHEET E4. COORDINATE THE EXACT REQUIREMENTS WITH SIGN VENDOR. OPROVIDE CONNECTION TO CEILING EXHAUST FAN /LIGHT COMBINATION. FAN AND LIGHT TO BE CONTROLLED BY COMMON SWITCH. OELECTRICAL SERVICE EQUIPMENT LOCATION. REFER TO SHEET E3, POWER RISER DIAGRAM AND PANELBOARD SCHEDULES. O THE STOREFR TIME CLOCK. q1E CLOCK SHALL BE SET TO MALLS OPERATING HOURS. O SPEAKER AND WIRING PROVIDED BY AEROPOSTALE'S VENDOR. ONLY IF REQUIRED BY MALL STANDARDS OR LOCAL CITY /BUILDING CODES, TENANT'S E.C. SHALL INSTALL 3/4" CONDUIT WITH PULLSTRING FROM EACH SPEAKER LOCATION TO A POINT DETERMINED BY AUDIO SUPPLIER AND BACK TO MANAGER'S DESK. COORDINATE EXACT SPEAKER TYPE, QUANTITIES AND LOCATIONS PRIOR TO ROUGH -IN. €::: COORDINATE EXACT LIGHT FIXTURE QUANTITIES, LOCATIONS AND CONNECTION REQUIREMENTS PRIOR TO BID. REFER TO ARCHITECTURAL DETAILS AND ELEVATIONS. O7 PROVIDE (2)DUPLEX RECEPTACLES MOUNTED VERTICALLY WITHIN FIXTURE, (1)DUPLEX AT 44" AND (1)DUPLEX AT 79" A.F.F. FOR SHELF LIGHTING. COORDINATE EXACT MOUNTING LOCATION AND REQUIREMENTS WITH FIXTURE SUPPLIER. REFER TO ARCHITECTURAL DETAILS. O8 REFER TO POWER PLAN SHEET E2 FOR POWER REQUIREMENTS AND LIGHT FIXTURES AT THIS LOCATION. OLIGHT FIXTURES (N) TO BE PLUGGED INTO RECESSED MOUNTED RECEPTACLES. REFER TO ARCHITECTURAL DETAILS. <> LIGHT FIXTURE TYPES 'M' AND 'H' IN THIS AREA ARE SURFACE MOUNTED FLUORESCENT STRIPS AT DECORATIVE ACCENT COVE WITH BLUE SLEEVE, GAM COLOR = #T740 OFF BLUE. .0> NOT USED. n • PROVIDE MOMENTARY CONTACT SWITCHES 'MC1' AND MC2'. .SWITCH 'MC1' SHALL CONTROL C1) LIGHTING CIRCUITS LA- 5,7,9,11,13,15. SWITCH 'MC2' SHALL CONTROL (C2) LIGHTING CIRCUITS LA- 4,6,8,10,12,14,16,18,20,22. LO8 0l5 00 L�L co CD 00 r W N Z 1-I 1-Li L UU� W v) HALLBERG ENGINEERING Mechanical /Electrical Consulting Engineers 1750 Commerce Court, White Bear Lake, MN 55110 (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS EXAIRES th/c' 12 JAN 0 4 2006 PE„,:" .c, T Eh LIGHTING PLAN SHEET NUMBER El L I G H T I N G F I X T U R E S C H E D U L E SYMBOL TYPE MFR. PRODUCT NO. FINISH DESCRIPTION LAMPING MTG. METHOD MTG. HGT. VOLTS COMMENTS T# TRACK JUNO T8WH -8', T12WH -12' WHITE SURFACE MNTD TRACK - -- CEILING 12' -O" 120 T# = TRACK LENGTH, REFER TO ELECTRICAL DWGS. FOR TRACK LENGTHS; SURFACE MOUNTED; 1 CIRCUIT TRACK A CON -TECH RAN3520MHX3 -BP2 WHITE RECESSED STORE FRONT ACCENT (3) 39W MH PAR20 RECESSED 12' -O" 120 RECESSED ADJUSTABLE ACCENT CLUSTER; ELECTRONIC BALLAST. SEE 4/A5 FOR TENTING. �O B JUNO SP3019WH WHITE ACCENT (1) 39W MH PAR20 TRACK 12' -O" 120 TRACK MOUNTED SINGLE LAMP ADJUSTABLE ACCENT FIXTURE; ELECTRONIC BALLAST an C LIGHTOLIER 4X9142HU /4X9PLCCDW WHITE RECESSED SALES FLOOR ACCENT (1) CF42DT /E /IN835 RECESSED 12' -0" 120 RECESSED ADJUSTABLE ACCENT CLUSTER; ELECTRONIC BALLAST. SEE 5/A5 FOR TENTING. F GROAN- NU TONE 680 WHITE FAN /LIGHT (1) 100 WATT INCAND. SURFACE CLG. HGT. 120 `. G A +L 4W -KD -T8 -2x32 WHITE STRIP LIGHT (2) 32W T8 3500K SURFACE CLG. HGT. 120 MOUNTING COMPONENTS FURNISHED & INSTALLED BY G.C. H A +L 55 /SID -1 F32T8 -48" WHITE STRIP LIGHT (1) 32W T8 3500K SURFACE COVE 120 ONE LAMP STAGGERED FLUORESCENT STRIP FIXTURE IN PERIMETER COVE J LAMAR B- C- 2- 17- E8 -1 -5 1/4 "X24" CHROME STRIP LIGHT (2) 17W T8 3500K WALL MOUNT 9' -4" 120 2' -0" SURFACE MOUNTED FLUORESCENT FIXTURE IN FITTING ROOM ` J -1 LAMAR B- C- 1- 32- E8 -1 -4 1/4 "X48" CHROME STRIP LIGHT (1) 32W T8 3500K WALL MOUNT 9' -4" 120 4' -0" SURFACE MOUNTED FLUORESCENT FIXTURE IN FITTING ROOM 1 0 L FOCUS CDL- 38- NL- EC -BLT BLACK BAMBOO FIXTURE LIGHT (1) 90PAR /HIR /SPI2XL LAMP IN FIXTURE 120 UPLIGHT LAMP HARDWIRE TO RECESSED JUNCTION BOX IN FLOOR M A +L SS /SID- 1F40T8 -60" WHITE PERIMETER FIXTURE (1) 40W T8 3500K SURFACE 10' -2" /COVE 120 SURFACE MOUNTED FLUORESCENT BARE LAMP ACCENT STRIP; ELECTRONIC BALLAST • 1 N HERA LIGHTING ES59BFPI -WW /BC -AERO WHITE SHELF ACCENT LIGHTING (1) 35W T5 SURFACE IN FIXTURE 120 SURFACE MOUNTED FLUORESCENT STRIP; ELECTRONIC BALLAST 1 11 P A +L STG- 2- F17 -T8 WHITE STRIP LIGHT (2) 17W T8 3500K FACTORY MOUNTED CASH WRAP 120 SURFACE STAGGERED MOUNTED FLUORESCENT STRIP IN CASHWRAP COUNTER; ELECTRONIC BALLAST -47> R CON -TECH RA8142HEMV- (1)42W TTT-CTR8427H-P-WMT WHITE ENTRY DOWNLIGHT (1) 42W TTT RECESSED BLK. HD. HEIGHT 120 RECESSED EXTERIOR DOWNLIGHT €4 W NAVILITE NXPB3RWH WHITE EXIT LIGHT INCLUDED WALL OR CEILING - -- 120 *SEE ELEVATIONS FOR STOREFRONT EXIT SIGN MTG. HGT. W1 NAVILITE N1WH WHITE EMER. LIGHT INCLUDED WALL 11' -3" DUAL --- W2 LIGHTALARMS 12PM36 -2(12) WHITE RECESSED EM ER. LIGHT MR16 -12W CEILING 12' -0" 120 COMPLETE SELF - CONTAINED UNIT WITH AUTOMATIC DOOR OPERATION II GENERAL NOTES A. B. �41.fifid42 ®oi2/w, Y ELECTRICAL CONTRACTOR TO REFER TO ARCHITECTURAL DRAWINGS FOR ALL LIGHT FIXTURE LOCATIONS. CONTRACTOR SHALL COMPLETELY REMOVE ALL EQUIPMENT, PANELBOARDS, DEVICES, FIXTURES, WIRING, CONDUIT, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. KEY NOTES OPROVIDE J -BOX AND WHIP FOR STORE SIGN. SIGN UL #E68384. SEE SPECIFICATIONS ON SHEET E4. COORDINATE THE EXACT REQUIREMENTS WITH SIGN VENDOR. OPROVIDE CONNECTION TO CEILING EXHAUST FAN /LIGHT COMBINATION. FAN AND LIGHT TO BE CONTROLLED BY COMMON SWITCH. OELECTRICAL SERVICE EQUIPMENT LOCATION. REFER TO SHEET E3, POWER RISER DIAGRAM AND PANELBOARD SCHEDULES. O THE STOREFR TIME CLOCK. q1E CLOCK SHALL BE SET TO MALLS OPERATING HOURS. O SPEAKER AND WIRING PROVIDED BY AEROPOSTALE'S VENDOR. ONLY IF REQUIRED BY MALL STANDARDS OR LOCAL CITY /BUILDING CODES, TENANT'S E.C. SHALL INSTALL 3/4" CONDUIT WITH PULLSTRING FROM EACH SPEAKER LOCATION TO A POINT DETERMINED BY AUDIO SUPPLIER AND BACK TO MANAGER'S DESK. COORDINATE EXACT SPEAKER TYPE, QUANTITIES AND LOCATIONS PRIOR TO ROUGH -IN. €::: COORDINATE EXACT LIGHT FIXTURE QUANTITIES, LOCATIONS AND CONNECTION REQUIREMENTS PRIOR TO BID. REFER TO ARCHITECTURAL DETAILS AND ELEVATIONS. O7 PROVIDE (2)DUPLEX RECEPTACLES MOUNTED VERTICALLY WITHIN FIXTURE, (1)DUPLEX AT 44" AND (1)DUPLEX AT 79" A.F.F. FOR SHELF LIGHTING. COORDINATE EXACT MOUNTING LOCATION AND REQUIREMENTS WITH FIXTURE SUPPLIER. REFER TO ARCHITECTURAL DETAILS. O8 REFER TO POWER PLAN SHEET E2 FOR POWER REQUIREMENTS AND LIGHT FIXTURES AT THIS LOCATION. OLIGHT FIXTURES (N) TO BE PLUGGED INTO RECESSED MOUNTED RECEPTACLES. REFER TO ARCHITECTURAL DETAILS. <> LIGHT FIXTURE TYPES 'M' AND 'H' IN THIS AREA ARE SURFACE MOUNTED FLUORESCENT STRIPS AT DECORATIVE ACCENT COVE WITH BLUE SLEEVE, GAM COLOR = #T740 OFF BLUE. .0> NOT USED. n • PROVIDE MOMENTARY CONTACT SWITCHES 'MC1' AND MC2'. .SWITCH 'MC1' SHALL CONTROL C1) LIGHTING CIRCUITS LA- 5,7,9,11,13,15. SWITCH 'MC2' SHALL CONTROL (C2) LIGHTING CIRCUITS LA- 4,6,8,10,12,14,16,18,20,22. LO8 0l5 00 L�L co CD 00 r W N Z 1-I 1-Li L UU� W v) HALLBERG ENGINEERING Mechanical /Electrical Consulting Engineers 1750 Commerce Court, White Bear Lake, MN 55110 (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS EXAIRES th/c' 12 JAN 0 4 2006 PE„,:" .c, T Eh LIGHTING PLAN SHEET NUMBER El LB -17 LB -17 -31 LB LA 36" LB -27 HA LB -22 ,5 -3 #8 --r LB -3 J77747727 7:97.8-.7777.07, .ii i i .evi /7/:AT.T/:7 .477.,"1- 7.0- 1'491C42'L.6ld'/ aid • i/1t7-/-a'atla7. 1, AO',1%.Q',! 8' -0" LB -28 w -4 1 LB-28 I* 10" LB -26 50-3/4" A.F.F. 4' -2" LB -17 -4 if L 4' -2 4' -24" !rl LB-26 50 -3/4" A.F.F. LB -26 50 -3/4" A.P.F. LB -26 50 -3/4" A.F.F. L -5 T 1— LB -30 LB -30 r W , #77/727777-,4777,7- � 11 loll/ LB -5 POWER PLAN 1/4" = 1' -0" NOTE: LANDLORD WILL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. TENANT SHALL CONTRACT WITH LANDLORDS DESIGNED FIRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORDS FIRE ALARM SYSTEM AT TENANT'S EXPENSE. TENANT SHALL USE ONLY LANDLORDS DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORDS FIRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHALL'S OFFICE. --1 LB -5 GENERAL NOTES A. CONTRACTOR SHALL COMPLETELY REMOVE ALL EQUIPMENT, PANELBOARDS, DEVICES, FIXTURES, WIRING, CONDUIT, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. KEY NOTES OPROVIDE CONDUITS WITH PULL WIRE BACK TO MANAGER'S DESK IN STOCKROOM. 1" MINIMUM, BUSH CONDUIT'S ENDS. </ TRENCH OR CORE BORE CONDUIT AND WIRE AS SHOWN. VERIFY ANY REQUIREMENTS WITH LANDLORD PRIOR TO BID. IF MORE THAN ONE (1) CONDUIT, CONDUIT SHALL BE IN COMMON TRENCH. CONDUIT SHOWN SOLID TO BE SURFACE MOUNTED ON FLOOR IN SPACE BELOW CASEWORK FROM STUB -UP LOCATION TO CASH REGISTER DEVICE LOCATIONS. REFER TO KEY NOTE #2. «:' THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSES. THE CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE THE CONDUIT FOR GROUNDING. ELECTRONIC CASH REGISTER OUTLETS SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL. 05 MAKE CONNECTION TO 277V/10, 8.3 KW WATER HEATER. MOUNT DISCONNECTING MEANS ADJACENT TO WATER HEATER. VERIFY EXACT LOCATION. 4::; ELECTRICAL SERVICE EQUIPMENT LOCATION. O. SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340-4G5-24VAC BUZZER, ONE (1) BUZZER LOCATED AT BACK WRAP WALL AND ONE (1) BUZZER NEXT TO MANAGER'S DESK, 852 WEATHERPROOF PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT, UNLESS REQUIRED BY THE LANDLORD OR LOCAL AUTHORITY. REUSE EXISTING IF APPLICABLE. 08 PROVIDE FLUSH RECESS MOUNTED DEVICES AS INDICATED FOR CONNECTION OF SEASONAL REGISTERS. COORDINATE EXACT LOCATION PRIOR TO ROUGH -IN. REFER TO ARCHITECTURAL PLANS FOR EXACT DIMENSIONING REQUIREMENTS. O PROVIDE J -BOX FOR GRAPHIC BOX. REFER TO DETAIL 5 ON SHEET E3 FOR MOUNTING HEIGHTS AND LOCATIONS. COORDINATE EXACT REQUIREMENTS WITH MANUFACTURER PRIOR TO ROUGH -IN. <> PROVIDE J -BOX IN ACCESSIBLE CEILING SPACE FOR SECURITY SYSTEM. COORDINATE EXACT REQUIREMENTS WITH SECURITY SYSTEM SUPPLIER PRIOR TO BID. 12 TIME CLOCK: PARAGON MODEL 7000- SERIES OR EQUAL WITH 7 DAY, 24 HOUR SCHEDULING FORMAT, MIN. (4) N.O. 20 AMP, 120/277 VOLT CONTACTS, 120 VOLT COIL AND SPRING WOUND RIDE THROUGH. SWITCH SHALL CONTROL STORE FRONT LIGHTING AND SIGN LIGHTING OR CONTACTOR(S) AS REQUIRED. PROVIDE RECESSED FLUSH WHITE DUPLEX RECEPTACLE AT SHOW WINDOW CEILING. <> PROVIDE (1) J -BOX AND (1) CEILING MOUNTED MOTION DETECTOR PER FITTING ROOM. MAKE REQUIRED CONNECTIONS TO JAMB SWITCH. INTERLOCK MOTION DETECTOR SUCH THAT UPON MOVEMENT IN FITTING ROOM THE MOTION DETECTOR CUTS POWER TO THE LIQUID CRYSTAL GLASS DOORS. G.C. TO PROVIDE 12' -15' OF EXTRA WIRE FOR J -BOX. COORDINATE EXACT REQUIREMENTS PRIOR TO BID. E.C. TO BRING POWER TO FITTING ROOM CONTROLLER PANEL AS INDICATED. RUN PIPES AND WIRES TO J -BOXES AT FITTING ROOMS. COORDINATE EXACT REQUIREMENTS WITH SUPPLIER. C> COORDINATE INSTALLATION OF RECEPTACLE WITH MILLWORK SUPPLIER. 15 DUPLEX RECEPTACLE TO BE MOUNTED HORIZONTALLY 6" ABOVE COUNTERTOP TO CENTERLINE. O. PROVIDE J -BOX FOR GRAPHIC BOX. COORDINATE LOCATION AND INSTALLATION REQUIREMENTS WITH GRAPHIC BOX MANUFACTURER PRIOR TO INSTALLATION. STOREFRONT GRAPHIC BOX, CIRCUIT LB -24 IS TO BE CONTROLLED BY THE TIME CLOCK. 17 TELEPHONE EQUIPMENT BACKBOARD LOCATION. 18 VAV UNIT (VAV -1), 480V, 3PH, BY MECHANICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ADJACENT TO UNIT A 30A, 3 POLE NON-FUSED DISCONNECT SWITCH. MAKE FINAL CONNECTIONS. COORDINATE WITH EQUIPMENT SUPPLIER. VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR. 19 TENANT SHALL INSTALL FIRE ALARM SYSTEM DEVICES AS REQUIRED BY THE DESIGN DOCUMENTS ISSUED BY LANDLORD'S FIRE ALARM CONTRACTOR. COORDINATE EXACT REQUIREMENTS WITH LANDLORD FIRE ALARM CONTRACTOR PRIOR TO BID AND INSTALLATION. LANDLORD'S FIRE ALARM CONTRACTOR WILL MAKE FINAL CONNECTIONS TO LANDLORD PROVIDED FIRE ALARM JUNCTION BOX AT TENANT'S EXPENSE. • • TRENCH OR CORE BORE CONDUIT AND WIRE AS SHOWN FOR CONNECTION TO TYPE 'P' LIGHT FIXTURES WITHIN CASH WRAP. VERIFY ANY TRENCHING REQUIREMENTS WITH LANDLORD PRIOR TO BID. IF MORE THAN ONE (1) CONDUIT, CONDUIT SHALL BE IN COMMON TRENCH. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET El. PROVIDE FIRE ALARM SYSTEM, SMOKE DETECTOR, STROBE OR HORN /STROBE DEVICES AS INDICATED AND CONNECT TO LANDLORD'S FIRE ALARM SYSTEM. COORDINATE WITH LANDLORD FIRE ALARM CONTRACTOR PRIOR TO BID AND INSTALLATION. REUSE EXISTING DEVICES IF APPLICABLE. TRENCH OR CORE BORE CONDUIT AND WIRE AS SHOWN FOR "L" LIGHT FIXTURE. E.C. TO PROVIDE RECESSED FLUSH JUNCTION BOX UNDER FIXTURE. VERIFY TRENCHING REQUIREMENTS WITH LANDLORD PRIOR TO BID. IF MORE THAN ONE (1) CONDUIT, CONDUIT SHALL BE IN COMMON TRENCH. CENTER IN FLOOR UNDER COVE ABOVE. REFER TO LIGHT FIXTURE SCHEDULE ON SHEET El. ELO9 0 l5 DATE: 11/21 /01 JOB NO: VI- 3201.62 DRAWN: DJQ CHECKED: KLS /JRP 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 co C 0 c0 a 0 0 U - t- 0 0 0 DEffm • cid 0.4 00 0 CO N ( 1 0 0 ar 0_ I— 1,n r. w HALLBERG ENGINEERING Mechanical /Electrical Consulting Engineers 1750 Commerce Court, Whlte Bear Lake, MN 55110 (651) 748 -•1100 • Fax (651) 748 -9370 REVISIONS POWER PLAN SHEET NUMBER JAN 0 4 200E E2 GL:: TEh 6 1'6" HARDWIRE EXIT HARDWIRE EXIT Storage 1,6„ r i i I Storage 2 4 2 1, '{\ � 4 -ti Poa 4_w Pow Dedi 4 -u 4 -2� Binders packs 4' -2 4'-2 4' -2 j . CD PI r Modem °° L Printer Hub Router Amplifier 2,6" 1 _ —Light °° ° ° Line 1 & 2 Phone Jack °° Line 4 (Modem) ® j5.—Phone PC ° ° Po' 2'6" d 4 -way Power Dedicated Filing Cabinet Drawer rn HARDWIRE EXIT HARDWIRE EXIT HARDWIRE EXIT r i i I z HARDWIRE EXIT " 4 -2� 4' -6" 4' -2 4'-2 4' -2 j . 'T h L I. . 17' -11° 16010 - GENERAL PROVISIONS A. WORK CONSISTS OF FURNISHING LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWN IN THE CONTRACT DOCUMENTS AND SPECIFIED IN DIVISION 16. B. INCLUDE ALL PARTS AND LABOR, WHICH ARE INCIDENTAL AND NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION EVEN THOUGH NOT SPECIFICALLY MENTIONED IN THE CONTRACT DOCUMENTS. SUCH ITEMS INCLUDE NUTS, BOLTS, ANCHORS, BRACKETS, SLEEVES, OFFSETS IN CONDUIT, FITTINGS, RELAYS, ETC. C. ARRANGE WITH LANDLORD TO PROVIDE TEMPORARY AND PERMANENT UTILITY SERVICES AS REQUIRED AND COORDINATE THEIR INSTALLATION WITH CONSTRUCTION PROGRESS OF THIS PROJECT. PAY ALL FEES AND COSTS CHARGED BY UTILITY COMPANIES FOR UTILITY SERVICES. D. OBTAIN ALL TEMPORARY AND PERMANENT PERMITS AND LICENSES REQUIRED IN CONNECTION WITH THIS DIVISION'S WORK. PAY ALL FEES AND EXPENSES REQUIRED FOR SUCH PERMITS AND LICENSES. E. REQUEST INSPECTIONS AS REQUIRED BY REGULATING AGENCIES AND /OR REGULATIONS. PAY ALL CHARGES FOR INSPECTIONS BY REGULATING AGENCIES OF INSTALLATIONS OF PLANS AND SPECIFICATIONS. F. INCLUDE STATE AND LOCAL SALES TAXES IN THE BID. KEEP ACCURATE RECORDS OF THESE TAXES AND FURNISH SUCH RECORDS TO THE TENANT UPON REQUEST. G. MEET OR EXCEED ALL CURRENT APPLICABLE CODES, ORDINANCES AND REGULATIONS FOR ALL INSTALLATIONS. PROMPTLY NOTIFY THE ENGINEER, IN WRITING, IF THE CONTRACT DOCUMENTS APPEAR TO CONFLICT WITH GOVERNING CODES AND REGULATIONS. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND COSTS FOR CORRECTING NON -COMPLYING WORK INSTALLED WITHOUT NOTIFYING THE ENGINEER H. HIGHER QUALITY OF WORKMANSHIP AND MATERIALS INDICATED IN THE CONTRACT DOCUMENTS TAKES PRECEDENCE OVER THAT ALLOWED IN REFERENCED CODES AND STANDARDS. I. THE TERMS DEFINED BELOW APPLY TO ALL WORK INCLUDED IN DIVISION 16. 1. THE WORK - AS DEFINED IN THE 1997 AIA DOCUMENT A201: "THE TERM WORK' MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS WHETHER COMPLETED OR PARTIALLY COMPLETED, AND INCLUDES ALL OTHER LABOR, MATERIALS, EQUIPMENT AND SERVICES PROVIDED OR TO BE PROVIDED BY THE CONTRACTOR TO FULFILL THE CONTRACTOR'S OBLIGATIONS. THE WORK MAY CONSTITUTE THE WHOLE OR A PART OF THE PROJECT." 2. FURNISH - TO OBTAIN IN NEW CONDITION READY FOR INSTALLATION INTO THE WORK. 3. INSTALL - TO STORE, SET IN PLACE, CONNECT AND PLACE INTO OPERATION INTO THE WORK. 4. PROVIDE -TO FURNISH AND INSTALL. 5. CONNECT - TO BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENT INCLUDING NECESSARY SWITCHES, OUTLETS, BOXES, TERMINATIONS, ETC. 6. CONDUIT - INCLUDES IN ADDITION TO CONDUIT, ALL FITTINGS, PULL BOXES, HANGERS AND OTHER SUPPORTS AND ACCESSORIES RELATED TO SUCH CONDUIT. 7. CONCEALED - HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, HUNG CEILINGS, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. 8. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. J. THE DRAWING AND SPECIFICATIONS CONSTITUTE THE CONTRACT DOCUMENTS. ANY ITEM NOTED IN THE SPECIFICATION OR SHOWN ON THE DRAWINGS IS INCLUDED IN THE CONTRACT DOCUMENTS. K. ALL ELECTRICAL DETAILS AND DRAWINGS ARE DIAGRAMMATIC, UNLESS SPECIFICALLY NOTED. FIELD VERIFY ALL DIMENSIONS AND NOTIFY THE ENGINEER OF ANY CONFLICTS OR DISCREPANCIES, IN WRITING, PRIOR TO INSTALLATION. L INITIATE, MAINTAIN AND SUPERVISE ALL SAFETY PRECAUTIONS REQUIRED WITH THIS WORK IN ACCORDANCE WITH THE REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) AND OTHER GOVERNING AGENCIES. M. DO NOT REMOVE OR DISTURB ANY ASBESTOS CONTAINING MATERIALS FROM THE PROJECT. IMMEDIATELY STOP WORK AND NOTIFY THE TENANT IF ASBESTOS CONTAINING MATERIALS ARE SUSPECTED. N. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED, EXAMINE THE SITE OF THE PROPOSED WORK AND BECOME THOROUGHLY FAMILIAR WITH EXISTING CONDITIONS AND LIMITATIONS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED NOR BIDDERS LACK OE KNOWLEDGE OF EXISTING CONDITIONS WHICH COULD HAVE BEEN DISCOVERED OR REASONABLY ANTICIPATED PRIORTO BIDDING. 0. CONDUITS, PIPES, DUCTS, LIGHTS, DEVICES, SPEAKERS, ETC., SHOWN ON THE DRAWINGS AS EXISTING HAVE BEEN BASED ON EXISTING PLANS AND MAY NOT BE INSTALLED AS ORIGINALLY SHOWN. IT IS THE CONTRACTORS RESPONSIBILITY TO VISIT THE SITE AND MAKE EXACT DETERMINATION OF THE EXISTENCE, LOCATION AND CONDITION OF SUCH FACILITIES PRIOR TO SUBMITTING A BID. P. CONSULT THE DRAWINGS AND SPECIFICATIONS OF MECHANICAL AND OTHER TRADES FOR CORRELATING INFORMATION AND LAY OUT WORK SO THAT IT WILL COORDINATE WITH OTHER TRADES. VERIFY DIMENSIONS AND CONDITIONS (I.E, FINISHED CEILING HEIGHTS, FOOTING AND FOUNDATION ELEVATIONS, BEAM DEPTHS, ETC.) WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. NOTIFY THE ARCHITECT/ENGINEER OF ANY CONFLICTS THAT CANNOT BE RESOLVED, IN THE FIELD, BY AFFECTED TRADES. REPLACEMENT OF WORK DUE TO LACK OF COORDINATION AND FAILURE TO VERIFY EXISTING CONDITIONS WILL BE COMPLETED AT NO COST TO THE TENANT. Q. INSTALL ALL CONDUIT, CABLE TRAY, BUSDUCT, EQUIPMENT, ETC. ALLOWING PROPER CODE AND MAINTENANCE CLEARANCES AND TO AVOID BLOCKING PASSAGEWAYS AND ACCESS PANELS. R WHERE WORK MUST BE REPLACED DUE TO THE FAILURE OF THE CONTRACTOR TO VERIFY THE CONDITIONS EXISTING ON THE JOB, SUCH REPLACEMENT MUST BE ACCOMPLISHED AT NO COST TO THE TENANT. THIS APPLIES TO SHOP FABRICATED WORK AS WELL AS TO WORK FABRICATED IN PLACE. S. THROUGHOUT THE COURSE OF THE WORK, MINOR CHANGES AND ADJUSTMENTS TO THE THE ENGINEER. THE CONTRACTOR SHALL MAKE INSTALLATION MAY BE REQUESTED BY TH L ADJUSTMENTS WITHOUT ADDITIONAL COST TO THE TENANT, WHERE SUCH ADJUSTMENTS ARE NECESSARY TO THE PROPER INSTALLATION AND OPERATION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. THIS DOES NOT INCLUDE WORK ALREADY COMPLETED. T. OBTAIN EXACT LOCATION OF CONNECTION TO EQUIPMENT, FURNISHED BY OTHERS, FROM THE PERSON FURNISHING THE EQUIPMENT. U. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER ONE IS AS BINDING AS IF CALLED FOR IN BOTH. V. INCLUDE THE BETTER QUALITY, GREATER QUANTITY OR HIGHER COST FOR AN ITEM OR ARRANGEMENT WHERE A DISAGREEMENT EXISTS IN THE DRAWINGS AND SPECIFICATIONS. W. GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR AFTER THE FINAL COMPLETION OF THE WORK AS EVIDENCED BY ISSUANCE OF THE FINAL CERTIFICATE BY THE ARCHITECT. X. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE TENANT AND ARCHITECT AND ENGINEER. INCLUDE DAMAGE TO THE FINISH OR THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS. Y. REPLACE ALL RECEPTACLES, SWITCHES, COVERPLATES, ETC., DAMAGED BY ANY CONTRACTOR DURING THE COURSE OF CONSTRUCTION. Z MATERIALS FURNISHED FOR THE TEMPORARY LIGHT AND POWER SYSTEM REMAIN CONTRACTORS PROPERTY, REMOVE WHEN THERE IS NO LONGER ANY NEED FOR TEMPORARY LIGHT AND POWER OR WHEN DIRECTED BY THE ARCHITECT.. AA. COORDINATE/SCHEDULE ALL WORK WITH THE TENANT TO MINIMIZE ANY DISRUPTIONS. CONFINE ALL INTERRUPTIONS TO THE SMALLEST POSSIBLE AREA. PROVIDE TEMPORARY CONNECTIONS IF REQUIRED TO PROVIDE CONTINUITY OF SERVICE BB. INSPECT ALL AREAS AFFECTED BY THE INTERRUPTIONS AND RETURN ALL AUTOMATICALLY CONTROLLED EQUIPMENT, ELECTRICALLY OPERATED EQUIPMENT TO THE SAME OPERATING CONDITION PRIOR TO THE INTERRUPTION. CC. NO FIRE ALARM SYSTEMS ARE TO REMAIN INACTIVE AT THE END OF THE WORK DAY. ASSURE THAT THE FIRE ALARM SYSTEM IS OPERATIONAL AT THE END OF EACH WORK DAY. COORDINATE WITH THE LANDLORD. DD. DO NOT DISTURB NORMAL USE OF THE FACILITY, EXCEPT WITHIN THE IMMEDIATE CONSTRUCTION AREA. KEEP WAYS, DRIVEWAYS, ENTRANCES, ETC. FREE AND CLEAR OF EQUIPMENT, MATERIAL AND DEBRIS. EE STORE ALL EQUIPMENT AND MATERIAL IN A PLACE AND MANNER THAT MINIMIZES CONGESTION AND IS APPROVED BY THE TENANT. FF. PROVIDE NEW MATERIAL AND EQUIPMENT, UNLESS NOTED OTHERWISE PROTECT EQUIPMENT AND MATERIAL FROM DAMAGE, DIRT AND THE WEATHER. GG. PROVIDE THE HIGHEST QUALITY WORKMANSHIP AND PERFORM ALL WORK ONLY BY SKILLED MECHANICS. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, INSTRUCTIONS AND CURRENT NECA STANDARDS. HH. THE TENANT RESERVES THE RIGHT TO REJECT MATERIAL OR WORKMANSHIP NOT IN ACCORDANCE WITH THE SPECIFICATIONS, BEFORE OR AFTER INSTALLATION. MM. PERFORM ALL CUTTING AND PATCHING NECESSARY TO WORK, UNLESS SPECIFICALLY DELEGATED TO THE GENERAL CONTRACTOR. OBTAIN SPECIAL PERMISSION FROM THE LANDLORD BEFORE CUTTING STRUCTURAL MEMBERS OR FINISHED MATERIAL. PERFORM ALL PATCHING IN SUCH A MANNER AS TO LEAVE NO VISIBLE TRACE AND RETURN THE AREA AFFECTED TO THE CONDITION OF UNDISTURBED WORK. PERFORM ALL PATCHING BY WORKERS EXPERIENCED, SKILLED, AND LICENSED FOR THE PARTICULAR TYPE OF WORK INVOLVED. INFERIOR WORK WILL NOT BE ACCEPTED. NN. PATCH ALL HOLES LEFT AS A RESULT OF DEMOLITION OF ELECTRICAL EQUIPMENT AND DEVICES. 00. PREVENT THE SPREAD OF DUST, DEBRIS, AND OTHER MATERIAL INTO ADJACENT AREAS. PP. REPLACE ALL CEILING TILES DAMAGED DURING INSTALLATION OF WORK, WITH NEW TILE QQ. PROVIDE MINIMUM 4' HIGH CONCRETE PADS FOR ALL FLOOR MOUNTED EQUIPMENT. RR. SIZE PAD TO PROVIDE A MINIMUM 2" OVERLAP AROUND PERIMETER OF EQUIPMENT. SS. REFINISH ALL ELECTRICAL EQUIPMENT DAMAGED DURING SHIPPING AND /OR INSTALLATION TO ITS ORIGINAL CONDITION, REMOVE ALL RUST; PRIME, AND PAINT PER MANUFACTURERS RECOMMENDATIONS FOR FINISH EQUAL TO ORIGINAL TT. PAINT ALL NEW RACEWAY SYSTEMS IN EXPOSED FINISHED AREAS UU. AFTER TESTS HAVE BEEN MADE AND ACCEPTED, CLEAN LIGHT FIXTURES, PANELS AND OTHER EQUIPMENT INSTALLED BY THE CONTRACTOR, LEAVING THE ENTIRE WORK AREA IN A CLEAN AND COMPLETE WORKING ORDER. W. OPERATE EQUIPMENT AND SYSTEMS IN ALL THEIR OPERATING MODES, TO VERIFY PROPER OPERATION, PRIOR TO FINAL INSPECTION AND OWNER INSTRUCTIONS. NOTIFY THE ENGINEER, IN WRITING, THAT ALL SYSTEMS HAVE BEEN TESTED AND ARE FUNCTIONING AND OPERATING PROPERLY WW. INCLUDE DOCUMENTATION OF INSTRUCTIONS IN THE OPERATION AND MAINTENANCE MANUALS. XX. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ELECTRICAL EQUIPMENT OR MATERIALS UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. KEEP ALL EQUIPMENT CLEAN MATERIALS UNTIL FINAL. ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. 16025 - DEMOLITION A EXAMINE THE BUILDING TO DETERMINE ACTUAL CONDITIONS AND EXTENT OF WORK PRIOR TO BIDDING THE PROJECT. REFER ANY UNCLEAR DETAILS OR CONFLICTS TO THE ARCHITECT /ENGINEER FOR CLARIFICATION PRIORTO BIDDING THE DRAWINGS. B. VERIFY THAT f, FIELD MEASUREMENTS AND CIRCUITING ARRANGEMENTS ARE AS SHOWN ON DRAWINGS. F C. VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES. D. BEGINNING OF DEMOLITION MEANS INSTALLER ACCEPTS EXISTING CONDITIONS. E. COORDINATE PHASING OF THE DEMOLITION WORK WITH THE CONSTRUCTION SEQUENCE SCHEDULE F. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. G. COORDINATE UTILITY SERVICE OUTAGES WITH LANDLORD. H. IDENTIFY EXISTING ELECTRICAL EQUIPMENT SUCH AS CONDUITS, BOXES, PULLBOXES, CONDUIT BODIES, AND CONDUIT RACKS THAT WILL NEED ADDITIONAL SUPPORT DUE TO THE DEMOLITION OF THE EXISTING SUPPORTS. I. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS, INCLUDING TELEPHONE AND DATA SYSTEMS, IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR CIRCUITS, USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. J. EXISTING ELECTRICAL SERVICE MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR SERVICE DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS NOTIFY AND OBTAIN PERMISSION FROM TENANT, ARCHITECT/ENGINEER AT LEAST 24 HOURS BEFORE PARTIALLY OR DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA K. EXISTING FIRE ALARM SYSTEM: MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS ACCEPTED. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM LANDLORD, ARCHITECT/ENGINEER AND LOCAL FIRE SERVICE AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREA ADJACENT TO WORK AREA. L. EXISTING TELEPHONE/DATA SYSTEM: MAINTAIN EXISTING SYSTEMS IN SERVICE UNTIL NEW SYSTEMS ARE COMPLETE AND READY FOR SERVICE AND ACCEPTED. DISABLE SYSTEMS ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM LANDLORD, ARCHITECT /ENGINEER AND TFI FPHONE UTILITY COMPANY AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA M. DEMOLISH AND EXTEND EXISTING ELECTRICAL WORK UNDER AND THIS SECTION, AND AS INDICATED ON THE DRAWINGS. REMOVE RELOCATE AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. N. PROVIDE SUPPORTS FOR ALL EXISTING ELECTRICAL EQUIPMENT THAT WAS SUPPORTED PREVIOUSLY BY DEMOLISHED WALLS, FLOORS, CEILING OR OTHER STRUCTURES. PROVIDE NEW SUPPORTS FROM STRUCTURAL MEMBERS NOT SLATED FOR DEMOLITION, PRIOR TO ANY DEMOLITION. 0. TENANT RESERVES THE RIGHT OF FIRST REFUSAL TO OBTAIN MATERIAL SHOWN TO BE REMOVED UNDER S CONTRACT. THE TENANT BECOME THE PROPERTY OF THE U ITEMS NOT RETAINED BY THI NTRA T. I CONTRACTOR AND MUST BE REMOVED FROM THE PREMISES. P. DEMOLISH AND REMOVE ALL ELECTRICAL SYSTEMS INDICATED FOR DEMOLITION. NO PORTION OF THESE SYSTEMS MAY BE ABANDONED IN PLACE. Q. REMOVE ABANDONED WIRING TO SOURCE OF SUPPLY. R. REMOVE EXPOSED ABANDONED CONDUIT, INCLUDING ABANDONED CONDUIT ABOVE ACCESSIBLE CEILING FINISHES. CUT CONDUIT IN WALLS, FLOORS, OR COLUMNS BACK TO A POINT WHERE PATCHING CAN BE ADEQUATELY PERFORMED AND PATCH SURFACES. S. DISCONNECT ABANDONED OUTLETS AND REMOVE DEVICES. REMOVE ABANDONED OUTLETS IF CONDUIT SERVICING THEM I5 ABANDONED AND REMOVED. PROVIDE BLANK COVER FOR ABANDONED OUTLETS, WHICH ARE NOT REMOVED. T. DISCONNECT AND REMOVE ABANDONED PANELBOARDS AND DISTRIBUTION EQUIPMENT. U. DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT SERVING UTILIZATION EQUIPMENT THAT HAS BEEN REMOVED. V. DISCONNECT AND REMOVE ABANDONED LUMINARIES. REMOVE BRACKETS, STEMS, HANGERS, AND OTHER ACCESSORIES. W. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. X_ MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS, WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS PANEL AS APPROPRIATE. Y. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. RELOCATE AND REROUTE CONDUIT AND WIRING AS REQUIRED FOR CONDUIT CONCEALED IN WALLS OR STRUCTURE BEING ALTERED AS PART OF THE REMODELING. MAINTAIN CONTINUITY TO ALL DEVICES IN AND DOWNSTREAM OF REMODELED WORK. Z. REROUTE EXISTING RACEWAY AND WIRING, WHICH IS EXPOSED DUE TO REMOVAL OF EXISTING CONSTRUCTION. CONCEAL NEW RACEWAY AND WIRING AND MAINTAIN OPERATION. AA. IF CONDUCTORS ARE REQUIRED TO BE REMOVED FROM EXISTING RACEWAYS, INSTALL WITH NEW CONDUCTORS. BB. PROVIDE NEW COVERPLATES THROUGHOUT THE REMODELED AREAS. CC. DISPOSE OF FLUO RES CENT LAMPS, BALLASTS, AN D OTHER HAZAR DOU S MATERIALS IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS. DD. PRIOR TO REINSTALLATION OF USED EQUIPMENT, THOROUGHLY INSPECT EACH ITEM AND REPORT ANY DEFECTS TO THE ENGINEER/ARCHITECT IN WRITING. INSTRUCTIONS FOR CORRECTIVE MEASURES WILL BE GIVEN AT THE TIME AND THE CONTRACT AMOUNT ADJUSTED ACCORDINGLY. IF C UNDER NO DEFECTS ARE REPORTED, THE MATERIAL WILL BE INCLUDED ND THE CONTRACTOR'S ONE- YEAR GUARANTEE AS OUTLINED IN SECTION 16010. EE. PANELBOARDS: CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING REVISED CIRCUITING ARRANGEMENT. FF. LUMINARIES: REMOVE EXISTING LUMINARIES FOR CLEANING. USE MILD DETERGENT TO CLEAN ALL EXTERIOR AND INTERIOR SURFACES; RINSE WITH CLEAN WATER AND WIPE DRY. REPLACE LAMPS, BALLASTS, AND BROKEN ELECTRICAL PARTS. GG. INSTALL RELOCATED MATERIALS AND EQUIPMENT AS INDICATED ON THE DRAWINGS. 16050 - BASIC MATERIALS AND METHODS A. ENCASE ALL CONDUCTORS IN A CONTINUOUS RACEWAY SYSTEM. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED BY THE NEC. SIZE ALL RACEWAY PER THE NEC WITH OVERSIZE CONDUITS AS INDICATED. PROVIDE MINIMUM 3/4" CONDUIT FOR BRANCH CIRCUIT HOMERUNS, PROVIDE MINIMUM 1/2" CONDUIT, UNLESS, NOTED OTHERWISE B. PROVIDE EMT FOR ALL CONDUCTORS UNLESS NOTED OTHERWISE. PROVIDE CONCRETE -TIGHT STEEL COMPRESSION OR STEEL SETSCREW TYPE FITTINGS, COUPLINGS AND BUSHINGS. CAST OR INDENTOR TYPE DEVICES ARE NOT ACCEPTABLE ALL FITTINGS USED IN PLENUM APPLICATIONS SHALL BE RATED FOR SUCH USE. C. PROVIDE EMC OR CONCRETE- ENCASED PVC CONDUIT FOR SERVICE ENTRANCE CONDUCTORS. D. PVC CONDUIT MAY BE USED UNDERGROUND OR BELOW CONCRETE SLABS. PROVIDE COATED RIGID STEEL ELBOWS FOR ALL ELBOWS WHERE PVC IS USED. E PROVIDE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO TRANSFORMERS, MOTORS AND OTHER VIBRATING PIECES OF EQUIPMENT. PROVIDE LIQUID -TIGHT CONDUIT FOR ALL CONNECTIONS IN DAMP OR WET LOCATIONS, PROVIDE GROUND TYPE FITTINGS AND GROUNDING CONDUCTOR INSIDE ALL FLEXIBLE CONDUIT. ADJUST CONDUIT SIZE IF REQUIRED. F. PROVIDE RECESSED OUTLET BOXES AND JUNCTION BOXES IN ALL NEW CONSTRUCTION. CONCEAL ALL CONDUIT WORK IN NEW CONSTRUCTION, EXCEPT MECHANICAL ROOMS. CONDUIT AND BOXES IN MECHANICAL ROOMS MAY BE RUN EXPOSED. G. PROVIDE EXPANSION FITTINGS WHERE RACEWAY CROSSES BUILDING EXPANSION JOINTS. 11. RUN ALL EXPOSED CONDUIT IN A NEAT, WORKMANLIKE MANNER PARALLEL TO THE BUILDING LINES, TIGHT TO THE WALL AND CEILING SURFACES, AND FIRMLY SUPPORT WITH CONDUIT CLAMPS OR HANGERS. PROVIDE TWO (2) HOLE MOUNTING STRAPS, MINIMUM THREE (3) FEET ON CENTER, FOR ALL SURFACE CONDUIT MOUNTED ON WALLS LESS THAN SIX (6) FEET ABOVE FINISHED FLOOR PLACE CONDUITS AT LEAST 8" AWAY FROM ALL HOT PIPING AND SURFACES INCLUDING DOMESTIC HOT WATER LINES. 1. PROVIDE GALVANIZED CODE GAUGE STEEL JUNCTION AND PULL BOXES WITH SCREW ON COVERS OF TYPE, SHAPE AND SIZE REQUIRED TO SUIT EACH INSTALLATION. PROVIDE GASKETING IN DAMP AND DUSTY LOCATIONS. PROVIDE CAST BOXES IN WEATHERPROOF, VAPOR TIGHT AND EXPLOSION PROOF ENVIRONMENTS. J. PROVIDE 4" BOXES THROUGHOUT. PROVIDE 31/2" DEEP BOXES WHERE INSTALLED IN MASONRY, 21 r2" MINIMUM ELSEWHERE PROVIDE SINGLE GANG MUD OR TILE RING FOR SINGLE DEVICES. K. MOUNT OUTLETS BOXES IN EXPOSED MASONRY WALLS WITH THE BOTTOM OF THE BOX ON THE TOP OF THE MORTAR JOINT AND THE VERTICAL LINE OF THE BOX EITHER ON THE MORTAR JOINT OR ON THE CENTER LINE OF THE MASONRY UNIT. PLUMB AND ACCURATELY ALIGN ALL WALL OUTLETS IN ROWS. MOUNT CEILING BOXES SYMMETRICAL WITH WALLS, BEAMS AND /OR TILES. MOUNTING HEIGHTS INDICATED ON THE DRAWINGS ARE FROM THE CENTER OF THE OUTLET BOX TO THE FINISHED FLOOR DIRECTLY BELOW THE OUTLET. EXTERIOR HEIGHTS ARE FROM INSIDE ADJACENT DOOR, OR IF NO DOOR, FROM THE FIRST FLOOR ABOVE GRADE, UNLESS NOTED OTHERWISE L. COORDINATE THE LOCATION OF ALL OUTLETS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS BEFORE INSTALLATION. COORDINATE ALL DOOR SWINGS IN THE FIELD BEFORE LOCATING SWITCHES. M. PROVIDE NEW WIRING DEVICES IN EACH OUTLET INDICATED ON THE DRAWINGS. PROVIDE ALL DEVICES FROM ONE MANUFACTURER. COLOR TO MATCH ADJACENT SURFACE N. APPROVED TOGGLE SWITCH MANUFACTURERS/MODEL NUMBERS: MANUFACT URER ,.. ,,! _. r. = OA(120"2 7.1F.WgLSWITCHE ._ 1- POLE 1 -POLE W /PILOT 2 -POLE 3 -WAY 4 -WAY KEYED 1 -POLE MOM. CONTACT ARROW HART HUBBELL PASS & SEYMOUR 1991 HBL- 1221 20AC1 19911 HBL- 1221PL 20AC1- RPL 1992 HBL- 1222 20AC2 1993 1994 1191L HBL- HBL- HBL- 1223 1224 1221L 20AC3 20AC4 20AC1 -L . 1995 HBL - 1556 1251 0. APPROVED STANDARD RECEPTACLE MANUFACTURERSIMODEL NUMBERS: MANUFACT URER 7V125 :STANDARD. RECEPTACLES . :V SIMPL EX DUPLEX GFI IG TVSS IGTVSS TAMPER RESISTANT ARROW HART . HUBBELL PASS & SEYMOUR LEVITON 5361 HB536 1 5361 5361A 5362 HB5362 5362 5362A GF5342 GF5362 • 2091 -- • IG5362 IG5362 IG6300 - 53625 5362S • NIA` - IG5362S IG5362S N/A. -- 6352 (15 AMP) N/A4' SG62 (15 AMP) - "PROVIDE THE CORRESPONDING HOSPITAL GRADE DEVICE WHEN THIS DEVICE IS USED. P. PROVIDE NEW COVERPLATES OVER ALL BOXES WITH THE FOLLOWING SPECIFICATIONS: ALL FINISHED AREAS AND UNFINISHED AREAS PROVIDE SMOOTH PLASTIC COVERS, COLOR TO MATCH ADJACENT SURFACE OR AS SELECTED BY THE ARCHITECT. PROVIDE APPROPRIATE COVERS OVER SPECIAL PURPOSE RECEPTACLES. PROVIDE NEW WEATHERPROOF COVERPLATES FOR OUTLETS AND SWITCHES AS INDICATED ON THE DRAWINGS AND FOR ALL EXTERIOR DEVICES. Q. PROVIDE WIRE AND CABLE WITH INSULATION VOLTAGE RATING EQUAL TO OR GREATER THAN THE APPLIED SYSTEM VOLTAGE. PROVIDE SOLID OR STRANDED COPPER CONDUCTORS WITH TYPE THWN, THHN, OR XHHN INSULATION FOR NO. 12 AWG AND NO. 10 AWG CONDUCTORS. PROVIDE STRANDED COPPER CONDUCTORS WITH TYPE THWN, THHN, OR XHHW INSULATION FOR NO. 8 AWG AND LARGER CONDUCTORS. PROVIDE MINIMUM NO. 12 AWG CONDUCTOR SIZE, UNLESS NOTED OTHERWISE. USE THE MINIMUM CONDUCTOR SIZE WHEN NO SIZE IS INDICATED. ALL CONDUCTORS TO BE COLOR- CODED AS FOLLOWS :120/208 VOLT SYSTEMS -PHASE A(BLACK), PHASE B(RED), PHASE C(BLUE), NEUTRAL(WHITE). 277/480 VOLT SYSTEMS -PHASE A(BROWN), PHASE B(ORANGE), PHASE C(YELLOW), NEUTRAL(WHITE WITH TRACER OR GRAY). GROUNDING SYSTEM(GREEN). R. PRIOR TO TURNING THE BUILDING OVER TO THE OWNER TURN ON ALL EQUIPMENT IN THE BUILDING INCLUDING LIGHTING AND WITH A MULTIMETER, READ THE CURRENT DRAWN ON EACH HOT LEG OF FEEDER SUPPLYING EACH DISTRIBUTION PANEL IF THE CURRENT IN ANY ONE LEG VARIES MORE THAN 5% (PLUS OR MINUS) FROM THE ARITHMETIC AVERAGE OF THE CURRENT IN ALL THE HOT LEGS, RECONNECT THE BRANCH CIRCUITS TO OBTAIN A BALANCED LOADING. S. PROVIDE FIRE BARRIERS AROUND CONDUIT, PIPE, TUBING, BUS DUCTS AND CABLES PASSING THROUGH SMOKE AND FIRE RATED FLOORS AND WALLS. PROVIDE CP 25, 303 AND P557904 SERIES BY OR "FLAME -SSAFE' SYSTEM BY THOMAS AND CORP FOR FIRE SEALS. 3M, BETTS C M, T. MAKE CONNECTIONS TO ALL MOTORS AND EQUIPMENT FURNISHED AND SET IN PLACE BY OTHERS. PROVIDE STARTERS, MANUAL CONTROLS AND AUXILIARY EQUIPMENT WHERE INDICATED IN SCHEDULES AND SPECIFIED HEREIN. PROVIDE ALL DISCONNECT SWITCHES AS INDICATED IN SCHEDULES, SPECIFIED HEREIN AND REQUIRED BY CODE. 16400 - POWER DISTRIBUTION A. RETAIL METERING CENTER 1. PROVIDE METER SECTIONS CONTAINING METER QUANTITIES AS INDICATED ON THE DRAWINGS. 2. PROVIDE METER BRANCHES RATED 200 AMP MAXIMUM. 3. PROVIDE 3 PHASE, 4 WIRE METERS FOR USE ON 120/208 VOLT AND 277/480 VOLT, 3 PHASE, 4 WIRE SYSTEMS WITH SEVEN (7) JAW METER SOCKETS. METERS FURNISHED BY THE UTILITY COMPANY. 4, MOUNT ALL OF THE ABOVE COMPONENTS AS SHOWN ON THE DRAWINGS IN A UL APPROVED AND LABELED, NEMA CLASS 1 FLOOR MOUNTED STEEL ENCLOSURE ENCLOSURE TO BE CONSTRUCTED TO FINISHED STEEL CLEANED, PRIMED, AND PAINTED WITH BAKED ENAMEL FINISH PRIOR TO SHIPMENT THE JOB SITE I B. PROVIDE FUSES OF THE FOLLOWING TYPES (BUSSMAN USED AS REFERENCE): 1. 600 AMPS AND ABOVE TIME -DELAY TYPE DESIGNED TO HOLD 500% OF RATED CURRENT FOR A MINIMUM OF 4 SECONDS AND CLEAR 20 TIMES CURRENT IN 0.01 SECONDS OR LESS WITH INTERRUPTING RATINGS OF 200,000 AMPERES RMS SYMMETRICAL AND PEAK LET - THROUGH CURRENT AND ENERGY LET - THROUGH VALUES ESTABLISHED BY U.L. STANDARD FOR CLASS L FUSES. PROVIDE KRP-C FUSES. 2. BELOW 600 AMPS: DUAL - ELEMENT CONSTRUCTION WITH INTERRUPTING RATING OF 200,000 AMPERES RMS SYMMETRICAL AND PEAK LET -THRU CURRENT ESTABLISHED BY U.L. STANDARD FOR CLASS RK -1 FUSES. PROVIDE LPN- RK/LPS -RK. 3. MOTOR CIRCUITS: PROTECT ALL INDIVIDUAL MOTOR CIRCUITS WITH FULL LOAD AMPERE 480 AMPERES OR LESS WITH DUAL -EL RATING (FLAX OF 48 DUAL-ELEMENT EM TIME -DELAY FUSES. PROVIDE LPN- RK/LPS -RK. PROTECT LARGER HORSEPOWER MOTORS WITH TIME -DELAY FUSES. PROVIDE KRP -C FUSES. PROVIDE U.L. CLASS RK1, DUAL - ELEMENT TIME -DELAY FOR ALL OTHER MOTORS,. 4. MOTOR CONTROLLERS: PROTECT NEMA AND IEC STYLE MOTOR CONTROLLERS WITH DUAL - ELEMENT, TIME -DELAY FUSES TO PROVIDE TYPE 2 COORDINATION FOR THE CONTROLLER. PROVIDE LPS -RK FUSES. 5. PROTECT CIRCUIT BREAKER PANELS WITH U.L CLASS RK1, CLASS L FUSES. PROVIDE LPN -RK, LPS -RK, OR KRP-C FUSES. 6. PROVIDE FUSE SIZES AS INDICATED ON THE DRAWINGS. 7. ACCEPTABLE MANUFACTURERS: BUSSMAN, FERRAZ -SHAWMUT OR LITTELFUSE OR PRE - APPROVED EQUAL. C. PROVIDE LIGHTING AND APPLIANCE PANELBOARD ASSEMBLIES ADHERING TO THE FOLLOWING SPECIFICATIONS: 1. ENCLOSURES CONSTRUCTED OF GALVANIZED SHEET STEEL OF THICKNESS AS REQUIRED BY CODE, WITH ENAMELED STEEL TRIM, DISTRIBUTED BUSING, HINGED STEEL DOORS LATCHES, LOCKS AND ADJUSTABLE TRIM CLAMPS. PROVIDE NEMA 3R ENCLOSURES FOR EXTERIOR LOCATIONS. 2. PROVIDE WELDED METAL FRAME WITH TYPED CIRCUIT DIRECTORY FOR EACH PANEL. 3. COMPLIANT TO THE FOLLOWING STANDARDS: UL 50, UL 67, NEMA PB -1, NFPA 70 AND FED. SPEC W- P -115C , UL 489, NEMA AB -1, FED. SPEC. W- C- 375B /GEN, IEC 157 -1 AND BS 4752. 4. COMPLIANT TO ARTICLE 384 OF THE NEC: "LIGHTING AND APPLIANCE PANELBOARD". MAXIMUM OF 42 POLES PER PANELBOARD ASSEMBLY. 5. PROVIDE PANELBOARDS WITH INTERRUPTING RATINGS AS SHOWN ON THE PLANS. 6. PROVIDE 240 VOLT AC RATED PANELBOARDS FOR 208/120 AND 240 VOLT AC SYSTEMS. PROVIDE 480/277 VOLT RATED PANELBOARDS FOR 480/277 VOLT SYSTEMS. 7. PROVIDE TIN - PLATED COPPER BUS BARS OR TIN - PLATED ALUMINUM BUS BARS. 8. PROVIDE PROPER LUGS (75° C. MINIMUM TEMPERATURE RATING) AND GUTTER SPACE FOR CABLE SIZE INDICATED ON THE PLANS. 9. PROVIDE ALL PANELS BY THE SAME MANUFACTURER. 10. PROVIDE SCREW MOUNTED, ENGRAVED NAMPLATES FOR EACH PANELBOARD, 11. PROVIDE MOLDED CASE, NON- ADJUSTABLE, THERMAL- MAGNETIC, QUICK -MAKE, QUICK - BREAK, BOLT -ON TYPE CIRCUIT BREAKERS. REFER TO THE SCHEDULES ON THE PLANS FOR SIZES AND QUANTITIES. 12. PROVIDE MULL -POLE BREAKERS WHERE INDICATED ON THE SCHEDULES. HANDLE TIES ON SINGLE POLE BREAKERS ARE NOT ACCEPTABLE 13. SERIES RATING OF CIRCUIT BREAKERS IS NOT ALLOWED. 14. ACCEPTABLE MANUFACTURERS: A 240 VOLT 1.SQUARE D TYPE NQOD OF NF 2.SIEMENS TYPE 51 SERIES 3.CUTLER HAMMER POW -R -LINE 1A SERIES 4.GENERAL ELECTRIC AQ SERIES 5.PRE- APPROVED EQUAL B. 480 VOLT 1.SQUARED D TYPE NF 2.SIEMENS TYPE S2 SERIES 3.CUTLER HAMMER POW -R -LINE 2A SERIES 4.GENERAL ELECTRIC AE SERIES 5.PRE- APPROVED EQUAL D. PROVIDE PANEL IDENTIFICATION LABEL FOR EACH PANEL INCLUDING PANEL NAME, VOLTAGE AND FEEDER. FOR EXAMPLE: °HDP -1 -1, 480/277 V, 30, 4 WIRE, 2 "C - 4# 4/0 THWN". E. MOUNT PANELBOARDS AND CABINETS TO BUILDING STRUCTURE OR INTERIOR WALL CONSTRUCTION. MOUNT INDEPENDENT OF CONDUIT AND RACEWAYS ENTERING BOXES. F. MOUNT PANELBOARDS WITH CABINET TOP AT 78" ABOVE FINISHED FLOOR G. PROVIDE 3/4 "EMPTY CONDUITS FROM EACH FLUSH MOUNTED PANELBOARD. WHEN THE FLOOR IS ON GRADE, PROVIDE THREE (3) CONDUITS INTO THE CEILING CAVITY ABOVE WHEN THE FLOOR HAS ACCESSIBLE SPACE BELOW, PROVIDE TWO (2) CONDUITS INTO THE CEILING SPACE ABOVE AND TWO (2) CONDUITS INTO THE ACCESSIBLE SPACE BELOW THE FLOOR. ENDS SHALL BE CAPPED AND SHALL BE TAGGED AT BOTH ENDS WITH PERMANENT TAGS. H. PROVIDE A CIRCUIT DIRECTORY COMPLETELY TYPED ON THE INTERIOR OF EACH PANEL DOOR. I. EQUIPMENT GROUND - SOLIDLY GROUND ALL CONDUIT SYSTEMS, SWITCH BOXES, CABINETS, MOTOR FRAMES, SWITCHGEAR, TRANSFORMERS, AND ALL OTHER PERMANENTLY INSTALLED EQUIPMENT IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE TO FORM A CONTINUOUS, PERMANENT AND EFFECTIVE GROUNDING SYSTEM. BOND EXPANSION JOINTS AND METAL RACEWAY SECTIONS. PROVIDE GROUND CONDUCTOR AS INDICATED ON THE DRAWINGS OR SPECIFIED HEREIN. J. WHEN CONNECTING SINGLE PHASE CIRCUITS AND EQUIPMENT TO A THREE (3) PHASE SYSTEM, DISTRIBUTE THE LOADS ON THE PHASES TO ACHIEVE AN APPROXIMATELY BALANCED LOADING OF THE THREE -PHASE SYSTEM. 16430 - MOTOR CONTROL A. PROVIDE "ON -OFF" TOGGLE TYPE MANUAL STARTER SWITCH WITH THERMAL OVERLOAD PROTECTION FOR SINGLE PHASE MOTORS, WHERE MANUAL CONTROL I5 INDICATED. PROVIDE EACH SWITCH WITH A RED PILOT LIGHT INDICATING WHEN MOTOR 15 ON. B. PROVIDE FULL VOLTAGE TYPE STARTERS AND THERMAL OVERLOAD PROTECTION AND EXTERNAL MANUAL RESET FOR ALL THREE -PHASE MOTORS, UNLESS INDICATED OTHERWISE. EQUIP EACH STARTER WITH 120 VOLT COIL, CONTROL POWER TRANSFORMER, SECONDARY FUSE BLOCK AND FUSES, AUXILIARY CONTACTS AS INDICATED, RED "ON" PILOT LIGHT, AND 'HAND-OFF-AUTO' CONTROL SWITCH. PROVIDE COMBINATION STARTER/DISCONNECT WHEN INDICATED ON THE PLANS. ACCEPTABLE MANUFACTURERS FOR MAGNETIC STARTERS: ALLEN- BRADLEY BULL. 509 &512, SQUARE D CLASS 8536, CUTLER HAMMER, GENERAL ELECTRIC, ITE/SIEMENS EQUIVALENT OR PRE - APPROVED EQUAL C. PROVIDE MANUAL MOTOR STARTING SWITCH OR TYPE 'SS" FUSED DISCONNECT ADJACENT TO EACH 120 VAC SINGLE PHASE MOTOR LOCATED OUT OF SIGHT AND /OR IN EXCESS OF 50' -0" FROM THE CONTROLLER, OR AS INDICATED ON THE DRAWINGS.. D. INTER LOCK ROOFTOP HVAC UNIT FAN STARTER WITH DUCT DETECTOR TO SHUT DOWN FAN UPON DETECTOR ACTIVATION. 16460 - TRANSFORMERS A PROVIDE VENTILATED, INDOOR, DRY -TYPE DISTRIBUTION TRANSFORMER WITH THE CAPACITY AND VOLTAGE CHARACTERISTICS INDICATED ON THE DRAWINGS. TRANSFORMERS 15 KVA AND ABOVE WILL BE DESIGNED TO OPERATE WITH A 115 DEGREES C. TEMPERATURE RISE ABOVE 40 DEGREES C. AMBIENT. PROVIDE ALL INSULATING MATERIALS FOR A 220 DEGREES C. INSULATION SYSTEM. B. PROVIDE TRANSFORMERS MEETING OR EXCEEDING NEMA CLASS 1 EFFICIENCY REQUIREMENTS AS REQUIRED IN THE LOCAL ENERGY CODE C. PROVIDE VOLTAGE TAP SAS INDICATED BELOW: 1. PROVIDE TWO 5% FCBN TAPS FOR ALL SINGLE AND 3 PHASE TRANSFORMERS 9 KVA AND BELOW. 2. PROVIDE TWO 2 1/2% FCBN AND TWO 2 1/2% FCAN TAPS FOR ALL 3 PHASE TRANSFORMERS 15 KVA AND BELOW. 3. PROVIDE FOUR 2 1/2% FCBN AND TWO 2 1/2% FCAN TAPS FOR ALL 3 PHASE TRANSFORMERS ABOVE 15 KVA D. PROVIDE SOUND RATINGS NOT EXCEEDING THE FOLLOWING LEVELS: 1. 0 TO 15 KVA, 40 DECIBELS. 2. 15 TO 50 KVA, 45 DECIBELS. 3. 50 TO 150 KVA, 50 DECIBELS. 4. 150 KVA OR GREATER, 50 DECIBELS. E. PROVIDE CONTINUOUS COPPER OR ALUMINUM COIL CONDUCTORS WITH BRAZED OR WELDED TERMINATIONS. F. ISOLATE TRANSFORMER CORE AND COIL FROM THE ENCLOSURE USING VIBRATION - ABSORBING MOUNTS. G. PROVIDE TRANSFORMERS 75 KVA OR LESS WITH ENCLOSURES SUITABLE FOR WALL, FLOOR OR TRAPEZE MOUNTING. PROVIDE TRANSFORMER LARGER THAN 75 KVA WITH ENCLOSURES SUITABLE FOR FLOOR OR TRAPEZE MOUNTING. H. PROVIDE MAXIMUM CASE TEMPERATURES NOT EXCEEDING A 35C TEMPERATURE RISE ABOVE A 40 DEGREE C AMBIENT. I. ACCEPTABLE MANUFACTURERS: CUTLER HAMMER, GENERAL ELECTRIC, SORGEL, HEVI -DUTY JEFFERSON ELECTRIC OR PRE - APPROVED EQUAL 16500 - LIGHTING A COMPLY WITH NEC AS APPLICABLE TO THE INSTALLATION AND CONSTRUCTION OF LIGHT FIXTURES. B. COMPLY WITH UBC AS APPLICABLE TO THE INSTALLATION AND CONSTRUCTION OF LIGHT FIXTURES. C. PROVIDE LIGHT FIXTURES THAT ARE LISTED AND LABELED BY U.L OR ANOTHER NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE APPLICATION. D. PROVIDE LAMP BALLASTS THAT COMPLY WITH CERTIFIED BALLAST MANUFACTURERS ASSOCIATION STANDARDS AND CARRY THE CBM LABEL E. COMPLY WITH ALL LOCAL, STATE AND FEDERAL ENERGY CODES. F. PROVIDE FIXTURES WITH LAMPS, FOR EACH OUTLET SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. SEE FIXTURES LIST ON THE PLAN. G. PROVIDE FLUORESCENT LAMP BALLASTS WITH THE FOLLOWING MINIMUM SPECIFICATIONS 1. PROVIDE U.L. LISTED AND LABELED, C.B.M. APPROVED BALLASTS. 2. PROGRAMMED RAPID START TECHNOLOGY TO ENSURE LONGEST LAMP LIFE. 3. T8 ONLY: PARALLEL -WIRED OPERATION TO ENSURE LIGHT OUTPUT FROM ONE BALLAST EVEN WITH ONE OR TWO LAMPS EXTINGUISHED. 4. COMPACT FLUORESCENT ONLY: SERIES WIRED LAMPS FOR MULTIPLE LAMP CONFIGURATIONS, AND PLUG -IN LEAD CONNECTORS FOR ALL LAMP LEADS 5. CLASS "P" RATED WITH THERMALLY ACTIVATED AUTOMATIC RESETTING PROTECTIVE DEVICES SEALED IN HOUSING. 6. CURRENT CREST FACTOR 1.7 OR LESS ON 60 HZ MODULATED CURRENT. 7. COMPLY WITH FCC RULES PART 18 REQUIREMENTS GOVERNING ELECTROMAGNETIC AND RADIO FREQUENCY INTERFERENCE 8. COMPLIES WITH IEEE 587 FOR WITHSTANDING LINE TRANSIENTS, VOLTAGE REGULATION + 10 PERCENT, LIGHT REGULATION ± 10 PERCENT. 9. BALLAST FACTOR 0.88 OR HIGHER 10. POWER FACTOR. GREATER THAN 95 PERCENT 11. SOUND RATING: `A° 12. MINIMUM 5 YEAR WARRANTY INCLUDING $10 /BALLAST LABOR 13. TOTAL HARMONIC DISTORTION: X20 %, BUT GREATER THAN 10 %. 14. END -OF -LIFE LAMP SENSING FOR ALL COMPACT FLUORESCENT BALLA H. APPROVED MANUFACTURERS - T8 ELECTRONIC BALLASTS 1. ADVANCE CENTIUM PROGRAM RAPID START SERIES 2. UNIVERSAL LIGHTING TECHNOLOGIES TRIAD ACCUSTART SERIES I. APPROVED MANUFACTURERS - COMPACT FLUORESCENT 1. MOTOROLA GOLD EDITION 2. ROBERTSON 3. OSRAM QUICKTRONIC SERIES 4. UNIVERSAL LIGHTING TECHNOLOGIES J. PROVIDE INSIDE FROSTED LAMPS WITH BRASS BASE, RATED 130 VOLTS FOR ALL INCANDESCENT LAMPS, UNLESS NOTED OTHERWISE. 1. APPROVED MANUFACTURERS REVIEWED Fa C CODE COMPLIANCE NFPA 70 - NEC JAN 1 7 2DGB TS. City OfTukw +l8 FOLDING DN S- ON. A. PHILIPS B. GENERAL ELECTRIC C. OSRAM/SYLVANIA D. PRE - APPROVED EQUAL K. PROVIDE MINIMUM 85 CRI FOR ALL FLUORESCENT LAMPS. PROVIDE 4100K COLOR LAMPS FOR ALL FLUORESCENT FIXTURES. 1. PROVIDE F032, F025 AND F017 T8 LAMPS FOR ALL 4', 3' AND 2' FIXTURES, RESPECTIVELY, UNLESS NOTED OTHERWISE. 2. APPROVED MANUFACTURERS: A. GE STARCOAT SPX B. PHILLIPS TL80 C. OSRAM SYLVANIA OCTRON 800XP L. PROVIDE SOLID STATE, SLID -TYPE DIMMERS SUITABLE FOR MOUNTING BEHIND A STANDARD DEPTH FACEPLATE AND FOR OPERATION ON COMMON NEUTRAL CIRCUITS. 1. PROVIDE 600 WATTS CAPACITY PER DIMMER UNLESS NOTED OTHERWISE ON THE PLANS, 2. ACCEPTABLE MANUFACTURERS: LUTRON NOVA T -STAR SERIES OR PRE - APPROVED EQUAL. M. SOLID STATE TYPE TIME SWITCHES. 1. PROVIDE SOLID STATE, PROGRAMMABLE 24 HOUR OR 7 -DAY, ELECTRIC TIME SWITCH WITH FOUR (4) SPST CONTACT RATED 20A AT 240 VOLTS, PROVIDE LONG LIFE LITHIUM BATTERY BACKUP TO MAINTAIN TIME AND MEMORY SETTING DURING A POWER OUTAGE. 2. PROVIDE ASTRONOMICAL CONTROL. 3. ACCEPTABLE MANUFACTURERS A. PARAGON EC7000 SERIES B. TORK MODEL D100 SERIES C. PRE - APPROVED EQUAL N. PROVIDE LIGHTING CONTACTORS THAT ADHERE TO THE FOLLOWING SPECIFICATIONS, WHERE LIGHTING CONTROL RELAYS OR CONTACTORS ARE CALLED OUT ON THE DRAWINGS: 1. ELECTRICALLY HELD RELAY, 30 AMP BALLAST RATED, 20 AMPS TUNGSTEN RATED @ 277 VOLTS 2. 2 POLE MINIMUM (REFER TO PLANS FOR REQUIRED POLES) 3. INSTALLED IN NEMA 1 ENCLOSURE INDOORS, NEMA 3R ENCLOSURE OUTDOORS. 4. COIL VOLTAGE: 24VAC. 5. COORDINATE ACCESSORIES WITH DIVISION 15'S EMS CONTRACTOR. 6. APPROVED MANUFACTURERS: A SQUARE D CLASS 8903, TYPE' L' SERIES B. ASCO 917 SERIES C. SIEMENS TYPE CLM D. PRE - APPROVED EQUAL 0. PROVIDE PHOTOELECTRIC SWITCH CONTROL WITH A SET OF SPST CONTACTS RATED AT 120 VOLT AC, 1800VA IN A NEMA 3R ENCLOSURE 1. UL LISTED. 2. APPROVED MANUFACTURERS: A PARAGON CW/210 SERIES B. TORK 2101 SERIES 3. IF USED AS A SENSOR INPUT TO THE LIGHTING CONTROL SYSTEM, PROVIDE PHOTOCELL CONTROLLERS FULLY - COMPATIBLE WITH THE LIGHTING CONTROL PANELS USED ON THIS PROJECT. REFER TO SECTION 16915. P. PROVIDE ALL HANGERS, RODS, MOUNTING BRACKETS, SUPPORTS, FRAMES, ETC. FOR PROPER AND SAFE FIXTURE INSTALLATION. INSTALL ALL FIXTURES IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AND INSTRUCTIONS. Q. PROVIDE FIXTURES COMPLETE WITH ALL AUXILIARIES REQUIRED FOR PROPER, SAFE AND DISTORTION FREE INSTALLATION IN THE VARIOUS CEILING CONSTRUCTIONS IN WHICH THEY APPEAR. COORDINATE CEILING TYPES WITH THE ARCHITECTURAL DRAWINGS AND PROVIDE COMPATIBLE FIXTURES. R. PROVIDE FELT OR FIBERGLASS GASKETS ON ALL INCANDESCENT LIGHTING FIXTURES WHERE NECESSARY TO PREVENT LIGHT LEAKAGE AT THE CEILING LINE 5. SECURELY SUPPORT ALL. LIGHT FIXTURES DIRECTLY FROM BUILDING STRUCTURAL MEMBERS OR 11/2° OR LARGER STEEL CEILING FRAMING CHANNELS. USE STEEL CHANNEL EQUIVALENT TO KINDORF #6029 WHERE IT I5 NECESSARY TO SPAN THE BUILDING STRUCTURAL MEMBERS FOR FIXTURE SUPPORT. WOOD SUPPORTING MEMBERS OR WIRES WILL NOT BE ACCEPTABLE. PROVIDE MINIMUM '/4" DIAMETER LAG SCREWS WHEN ANCHORING INTO WOOD STRUCTURAL MEMBERS. PENETRATE WOOD STRUCTURAL MEMBERS A MINIMUM OF 2° WITH ALL SCREWS. PROVIDE STEEL OR LEAD, EXPANDABLE TYPE, ANCHORS WITH MINIMUM PENETRATION OF 11/2° WHEN ANCHORING TO CONCRETE WHEN INSTALLING LIGHT FIXTURES IN A SEISMIC ZONE, SECURE TO MEET ALL REQUIREMENTS. T. DO NOT SUSPEND ANY CONDUIT, LIGHT FIXTURES, OR BALLASTS FROM METAL ROOF DECK OR FROM THE CEILING SUSPENSION WIRES. SUPPORT ALL LAY -IN FIXTURES INDEPENDENT OF THE CEILING SUPPORT SYSTEM. PROVIDE FASTENING CLIPS ON EACH CORNER OF EACH FIXTURE IN ACCORDANCE WITH THE UBC AND STATE BUILDING CODES. U. EQUIP ALL FIXTURES USING CONDUIT STEMS WITH BALL SWIVEL HANGERS. IN FINISHED AREAS, PROVIDE CANOPIES FOR THE HANGERS. V. SUPPORT ALL SURFACE MOUNTED FLUORESCENT FIXTURES WITH A MINIMUM OF ONE HANGER PER FIXTURE PLUS ONE PER ROW. SUPPORT INDIVIDUAL FIXTURES WITH A MINIMUM OF TWO HANGERS. ATTACH FIXTURE HANGERS TO THE CEILING GRID PER CODE. W. SUPPORT ALL SUSPENDED FLUORESCENT FIXTURES WITH A MINIMUM OF TWO FIXTURE HANGERS. ATTACH EACH HANGAR TO A DEDICATED ANCHOR LOCATE HANGARS DIRECTLY ABOVE THE CORNERS OF THE LIGHT FIXTURES. X. WHERE MASTERISLAVE OR INBOARD /OUTBOARD SWITCHING IS INDICATED, PROVIDE TANDEM -WIRED BALLASTS BETWEEN LIGHT FIXTURES AS REQUIRED BY THE LOCAL ENERGY CODE Y. WIRE ALL RECESSED LAY -IN FIXTURES WITH 6 FEET OF FLEXIBLE METAL CONDUIT WITH TYPE "THHNJTHWN" WIRE TO THE OUTLET BOX. PROVIDE GROUNDING TYPE CONNECTORS FOR ALL CONDUIT AND CABLE. Z. PROVIDE OUTLET BOXES ADJACENT TO EACH RECESSED FIXTURE OUTLET IN SUSPENDED CEILINGS TO PERMIT EACH FIXTURE TO BE ADJUSTED TO FIT CEILING PATTERN AND TO PERMIT "FEED THROUGH" WIRING. AA. AT THE TIME OF SUBSTANTIAL COMPLETION, ALL FIXTURES MUST BE INSTALLED AND LAMPED WITH NEW LAMPS. INSTALL ALL FIXTURES COMPLETE WITH LENSES, DIFFUSERS, REFLECTORS, LOUVERS AND OTHER REQUIRED ACCESSORIES. BB. REPLACE ANY DAMAGED REFLECTORS, DIFFUSERS, LOUVERS OR OTHER COMPONENTS AT NO EXPENSE TO THE OWNER. CC. CLEAN ALL FIXTURES FREE OF DUST, FINGER PRINTS, PAINT, ETC.. DD. PERFORM AIMING AND ADJUSTMENT OF ALL LIGHTING FIXTURES IN ACCORDANCE WITH INSTRUCTIONS ISSUED BY THE ENGINEER/TENANT. ADJUST ALL DIRECTIONAL TYPE FIXTURES (INTERIOR AND EXTERIOR) AFTER DARK UNDER THE DIRECTION OF THE ARCHITECT, ENGINEER, AND /OR TENANT. EE. REPLACE ALL DEFECTIVE BALLASTS WITHIN THE GUARANTEE PERIOD AT NO COST TO THE TENANT. FF. INSTALL DIMMERS WHERE INDICATED ON THE DRAWINGS. 1. WHERE DIMMERS ARE SHOWN GANGED WITH OTHER DIMMERS AND /OR OTHER DEVICES, SIZE OUTLET SUCH THAT DIMMERS WILL NOT BE UNDERATED. GG. INSTALL PHOTOCELL(S) PER MANUFACTURER'S RECOMMENDATIONS. 1. AIM AWAY FROM ARTIFICIAL LIGHT SOURCES SUCH AS STREET LIGHTS OR SECURITY LIGHTS. 2. SEAL PENETRATIONS THROUGH ROOF OR PENTHOUSE WALL. HH. INSTALL TIME SWITCHES ADJACENT TO THE SOURCE LIGHTING PANEL, UNLESS SPECIFICALLY LOCATED ELSEWHERE ON THE PLANS. 1. SET LONGITUDE AND LATITUDE SETTINGS AND THE ASTRONOMICAL TIME 2. PROVIDE TIME SETTINGS PER THE TENANT'S DIRECTION. MMM.PROVIDE "NAMEPLATES" A SPECIFIED IN SECTION 16050 FOR ALL CONTACTORS AND TIME SWITCHES. LABEL CONTACTORS AND TIME SWITCHES TO INDICATE LOAD SERVED (EG., CANOPY LIGHTS, STORE SIGN, ETC.). 16535 - EMERGENCY LIGHTING A PROVIDE AUTOMATIC BATTERY POWERED LIGHTING UNITS AS INDICATED ON THE DRAWINGS. B. PROVIDE EMERGENCY LIGHTING AS SHOWN ON THE PLANS TO ILLUMINATE THE EGRESS CORRIDORS AND OTHER REQUIRED AREAS. REFER TO THE LIGHT FIXTURE SCHEDULE ON THE DRAWINGS FOR TYPES. C. PROVIDE AN INTENSITY OF NOT LESS THAN 1.0 FOOTCANDLE AT THE FLOOR LEVEL ALONG THE PATH OF EGRESS. D. PROVIDE AN EXIT LIGHT AT EACH EXIT AND ALONG THE EGRESS PATH AS REQUIRED. E CONNECT EMERGENCY LIGHTS TO THE UNSWITCHED BRANCH CIRCUIT(S) IN THE AREA PROVIDE HANDLE -LOCK DEVICE FOR THAT CIRCUIT. 16741 - VOICE AND DATA RACEWAY A PROVIDE 4" SQUARE BOXES FOR EACH RECESSED OUTLET BOX. PROVIDE 3W DEEP MASONRY TYPE IN RECESSED MASONRY INSTALLATIONS. PROVIDE MUD OR TILE RING AS REQUIRED FOR ALL BOXES. B. PROVIDE THE FOLLOWING IN ACCESSIBLE CEILINGS AS FOLLOWS: PROVIDE AN EMPTY BOX WITH (1) 314" CONDUIT STUBBED INTO CEILING SPACE FOR EACH TELEPHONE OUTLET INDICATED ON THE DRAWINGS; PROVIDE AN EMPTY BOX WITH (2) 3/4" CONDUIT STUBBED INTO CEILING SPACE FOR EACH DATA, VOICE/DATA OR FIBER OPTIC OUTLET INDICATED ON THE DRAWINGS. C, PROVIDE THE FOLLOWING IN INACCESSIBLE CEILINGS (PLASTER, SPLINE, GYPSUM, SECURITY GRID, PLANK, ETC.) AS FOLLOWS: PROVIDE AN EMPTY BOX WITH (1) 3/4" CONDUIT ROUTED TO THE NEAREST TELEPHONE BACKBOARD LOCATION FOR EACH TELEPHONE OUTLET, UNLESS NOTED OTHERWISE ON THE PLANS; PROVIDE AN EMPTY BOX WITH (2) 3/4° CONDUIT ROUTED TO THE NEAREST COMMUNICATIONS CLOSET BACKBOARD LOCATION FOR EACH DATA, VOICE/DATA, OR FIBER OPTIC OUTLET, UNLESS NOTED OTHERWISE ON THE PLANS. ■ N „ AC or Romex type wiring allowed. • ELO6O1S DATE: 11/21/01 JOB NO: 01- 3201.62 DRAWN: DJQ CHECKED: KLS /JIRP 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 Project Coordination • rin 1.0 cid a. WA 98188 HALLBERG ENGINEERING IMechank d /Electrical Consulting Engineers 1750 Commerce Court, White Bear Lake, MN 55110 (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS JAN 0 4 NIA PEA- v i ULN Eh No ,attachment or support from any roof deck is allowed. Hangers, damps and supports shall be fastened bar- joists ar beams only. , • All cabling shall be plenum rated. All Tenants served by landlords air conditioning units have pIErrurm returns. ELECTRICAL SPECIFICATION SHEET NUMBER E4