Permit EL08-0043 - WELLS FARGO
WELLS FARGO 6815 S 180 ST ELO8-043 CitAbf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 3623049095 Address: 6815 S 180 ST TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -043 Issue Date: 03/17/2008 Permit Expires On: 09/13/2008 Tenant: Name: WELLS FARGO Address: 6815 S 180 ST , TUKWILA WA Owner: Name: FIRST INTER BNK- KIRKLAND Phone: Address: WELLS FARGO BANK - 92685 , PO BOX 63931 Contact Person: Name: JESSICA BRADLEY Phone: 206 -720 -7001 Address: 1932 FIRST AVE SUITE 408 , SEATTLE WA Contractor: Name: KIRBY ELECTRIC INC Address: 4826 B ST NW, STE 101 , AUBURN WA Contractor License No: KIRBYEI077BN Phone: 253 859 -2000 Expiration Date: 01/13/2009 DESCRIPTION OF WORK: NEW SINGLE STORY OFFICE/MANUFACTURING BUILDING. NEW SITE LIGHTING, NEW GENERATOR Value of Electrical: 668,558.00 Fees Collected: $8,579.38 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and Date: CC/3( rTi6O ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ri4h, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -043 Printed: 03 -17 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 3623049095 Address: 6815 S 180 ST TUKW Suite No: Tenant: WELLS FARGO PERMIT CONDITIONS Permit Number: EL08 -043 Status: ISSUED Applied Date: 01/11/2008 Issue Date: 03/17/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Print Name: /4MdU G%i J I. Date: ,3/7 C 7g doc: Cond -Elec EL08 -043 Printed: 03 -17 -2008 CITY OF TUKWIL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:ll www. ci. tukwila. wa. us Electrical Permit No. .4--W 6 0 3 Ic001-00/ Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 3 CD 2.-3 0 A alO9,C Site Address: al S oukh I \1 tr\t\ . _ / ivku'� \a , Suite Number: Tenant Name: \IA eA S F °A y Property Owners Name: \tom \t\ S Mailing Address: c\GN -5 c k 1\\12xts� Floor: New Tenant: ❑ Yes g..No 5 Calk City \�1 R State 1\3 101‘ Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: - SQ.4SLco, 90 Crv��gy Mailing Address: \C\?j2 c-NM 'i Seai k VAC,k State Zip Day Telephone: (ZSJ6� 7 ` 706 E -Mail Address: `..c \.CO c't 0.V6Kkke,C4c5 C11`1t� City Fax Number: L2.0C9 77-0 - -Z-CAL{ ELECTRICAL CONTRACTOR INFORMATION Company Name: (OWtP TL11v IP, 1132 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ WWT/1 q0• Scope of Work (please provide detailed information): N SIP1( 4- Uhl' WrAki UIciIJG 13.thoiNq. N l tI'M. 1- I4It1\Kci. NOV 6i V$MTah- • Will service be altered? Yes_ Type of Use: $- Witt FA til Type of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light No Adding more than 50 amps? ) Yes ❑ No ❑ Service Change ❑ Fire Alarm 11 \Apphwnons \Forms- Apphcattons (hr l.me'4 2007 Elenncal Permit Application doe bh ❑ Remodel ❑ Tenant improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERIVIIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 1 ' TRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Pl.-0141.w( 4t- Boa Day Telephone: City Date: t) (1-01 \t�— &1c 1 State Zip IDate Application Accepted: I — Date Application Expires: 7 -H- d' Staff Initials: H.\Apphcanons \Forms- Applications tht 1.mc14 -2007 - F.Icctncal Pcrmn Applicann .dnt bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http :• / /www.ci.tukwila.wa.us Parcel No.: 3623049095 Address: 6815 S 180 ST TUKW Suite No: Applicant: WELLS FARGO RECEIPT Permit Number: EL08 -043 Status: APPROVED Applied Date: 01/11/2008 Issue Date: Receipt No.: R08 -00769 Initials: User ID: Payee: JEM 1165 Payment Amount: $6,863.50 Payment Date: 03/17/2008 09:01 AM Balance: $0.00 CRAFT ARCHITECTS, PLLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3409 6,863.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 6,863.50 Total: $6,863.50 )3/17 ; 710 TOTA... 686:'-50 doc: Receiot -06 Printed: 03 -17 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 3623049095 Address: 6855 S 180 ST TUKW Suite No: Applicant: WELLS FARGO RECEIPT Permit Number: EL08 -043 Status: PENDING Applied Date: 01/11/2008 Issue Date: Receipt No.: R08 -00107 Initials: WER User ID: 1655 Payment Amount: $1,715.88 Payment Date: 01/11/2008 02:38 PM Balance: $6,863.50 Payee: CRAFT ARCHITECTS TRANSACTION LIST: Type Method Description Amount Payment Check 3337 1,715.88 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 1,715.88 Total: $1,715.88 7131 01/11 .9710 TOTAL 171588 doc: Receiot -06 Printed: 01 -11 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD _atf Retain a copy with permit PERMIT NO. (206)431 -3670 Prod c : �.5 /fit & C2 Type of Inspection: SIG 1 A r ' Date Called: Special Instructions:. Date Wante4 /8 rryr/ Requester: Phone No: `;;proved per applicable codes. Ij Corrections required prior to approval. OMMENTS: Inspec r:' 5/L1 i /0/ Date: Y /VO? ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit ft - *3 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. Project: f.-ii a.s f -G 0 Type of Inspection: F /AM L. ,r n /. Date Called: 077/1,4 -r 4'' T eft 1 0 A 4Y'. Special Instructions: Date Wanted: �, / ° p Requester: �Ai<1 Ik T/( /� fcA4 f."h '7 0/0/97-04S Phone No: 0 Approved per applicable codes. - Corrections required prior to approval. COMMENTS: e 1)fl1'v'M t ;:' w,)6`l fog /l1c,T�. Ilor 5auriz. TAP s7-'4,s X Ade 4/s% -,A Fog is 077/1,4 -r 4'' T eft 1 0 A 4Y'. Ns Cvi)/VF. c. r- A r t/447-1A i,i rXUG/C my 0i: U4/6. oh c L Fa< 77/111-K G ', 15 Fars 4/44 e.1 '' L/G #73". Will) /aL AMA/1efi96- 7H/t,'4s IN.(7xti41? 7a AI �Ai<1 Ik T/( /� fcA4 f."h '7 0/0/97-04S VIMT/1y /2V v/' Ey///`157 r-git) C Inspect /)1/7-1Y O pate: _3/ / q El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 1� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Ins ction: Ad s. S/ -�rj llJJ�, �� Date Called: Special instructions: Date Wanted: /�L a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: ,`9 fr/e/14 ft SLR/ / /7i/ 9- u Inspect / 1 (Date: :--►/2.,1/� El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ■■■L.l e.,.� r.. n, 0.11.-. .•• • •1,....0.240 INSPECTION NO. INSPECTION RECORD Retain a copy with permit (c ' -Q9j PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P.m 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 qt- Project: a 70 / /2,42 Type of s io V / -2QA 7 Address: ?Si" S /KO - f Date Called: Special Instructions: Date Wanted: ...- /1- 7 a.m. p.m. Requester: Phone No: r. proved per applicable codes. f Corrections required prior to approval. COMMENTS: 70 / /2,42 g — '6 C0/1 // 7. S7T w %,/ /TM4/ - ,N /9/7449 C24' v- Gam: 70g — G/fil ,5-ALE "/G .<-U / /aic r a¢ r77,//' f/107//14‘ 7i / C... /4/A16 6X/Z Inspector* _./L T 1y6H IDatW;. -7/Q� ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION ;R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 , (206)431 -3670 Project: ca *c � (0 Type of Ins ction: Aid - ifirAr /C( -7- Sr D to Called: pecial Instructions: .r- Date Wanted: 7.-4r a.m. P.m. Requester: Phone No: A. . roved per applicable codes. El Corrections required prior to approval. OMMENTS:f,Z) O� – (/( -- s/ /..-/6/7/7-/4/a• 4�� / 7-41e/11C-17/465 Insp I-L 1L9 i 4'V4,10/ Date:/ / El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit PERMIT INSPECTION NO. N • CITY OF TUKWILA BUILDING DIVISION %- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: pddreeks ( G Cl Type of Inspection: ss. Date Called: /e (/- F/ t- Special Instructions: Date Wanted: �`� li.,,,,„ri-- Requester: ! /4-/-/../ Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: re/ 64-- Li& --- ,` " /e (/- F/ t- ,:inz --- s./77 ! /4-/-/../ ,416. //..- /9',1,4.64- s Ins ec r. Date. , EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: s INSPECTION NO. INSPECTION RECORD Retain a copy with perm! PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- Project: F G Type of Inspection: t Date Called: Special Instructions: Date Wanted: �� 3 a.m. p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: fyi. j — �f y/c 4 T- 77(2//9/►/5/, So)/7-6-171 ,9N1) /11, 1 2 "XVUI O.< - a& 7 6L41/,4 T Inspegio: Date /3 h p ri$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: t.,..r- •,elk •v'. •s �•04ese'40s. "•4 t9 'p .a.- v).ah. Nat fi. aatuµ •.Aetl!Y110M.Awywxmtkit;w ere e 02. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 446 1�N)'CL4,l��r Type of Inspection: ri Address: �, Date Called: Special Instructions: Date Wanted: /�a) Requester: Phone No: Approved per applicable codes. 5ZIF required prior to approval. COMMENTS: In `� S,� V/ C. t , / ,/JV1/:o1// 444 /,1V (`Z4 /k `4 0/11 G }` c/4, - a i L. CLJ/N 6IzA 4 of b21,/44- y N67?/ — g'i e MIN 409/1)48 Ti/74',,c-FE /T G. /.7 Insp at: f'4fi//f/ Date: .�, El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .�_._ a... st,...4. ,..a..,. - &Laaa_x .. • I., al _ _S • • INSPECTION NO. INSPECTION RECORD ����-Uy� Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /AJt LL 1/MI G U Type of Inspection: 7700/ Olt 116- dress: Date Called: NcY 7?/ f /0\ Special Instructions: Date Wanted: //---? a.m. p.m. Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. 7EOMMENTS/ 7 %% Olt 116- NcY 7?/ f /0\ r f /f = T/ r i I ri/6 r -- i l& A /.kz 7; 105761- /0' el <. \■ Date i/y b k9. ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: )v INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /12' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 -Project: g 1 5 f L f) Type of Inspection: `/ drre Date Called: ° Jo /7,4JG f /� Special Instructions: Date Wanted: //T 1 _ A —'/ �� a:m: Requester: Phone No: pproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Pot ` - L'✓4S7- ° Jo /7,4JG f /� 7 _ A —'/ �� fV,p2- aCi/6 z..o" I /TS Insp.. /CL ..Sf4%!9L/(U /7/ Date: // g. /y ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: ,Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit fLUfy- U`/3I PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: q'--- OK I a T 4 )0 0 ,18491/4- gtDate Called: fncf_ ;f (4 NfLS Special Instructions: Date Wanted: —� / �.� a.m. p.m. Requester: Phone No: roved per applicable codes. Corrections required prior to approval. Z COMMENTS: fig. q'--- OK I a T 4 )0 0 ,18491/4- ft)frC /4) .44fc4L- ` 1 -- cr 1(.0fx Awsr , arm //f v-- fncf_ ;f (4 NfLS Inspectoy l L 1 (A PC Date //?/(7 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: )Date: Es? INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. P ject: r lived- S 1-1946 G Type of Inspection: 7 GO I Ad ress: ^� kg 0 c % Date Called: - Special Instructions: Date Wanted: / 7 ., �,�( Requester: Phone No: proved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: tX IA/ ii- ,, 6 S Inspect(�,`L A/ e r f` i y'- ne6 Date: //,7 /0 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit beg- 01/ 3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: WELLS f 6 a Type of Inspection: ) J Address: 72/ Date Called: Special Instructions: Date Wanted: / a. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: pei. if)- Mkt. --acYcg /5/75 Inspe c LJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. - CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Miks bit-4a Type of Inspection: —w S Address: / r) ! Date Called: Special instructions: Date Wanted: r2M a. Requester: Phone No: 1;5.... per applicable codes. CE}MMENTS: M 0 Corrections required prior to approval. r /,j47 ; L c_01/, C pccicr rici,76X Inspe - >/ 1 Date , // /( Z r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: _... .1. __ , INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1/2-• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: pia $ "WAG 0 Type of Inspection: -7.67)1 d re ,40-21 Date Called: Special Instructions: ..."' Date Wanted: /p /<1 4;--. a.m. .m. Requester: Phone No: p p ved per applicable codes. Corrections required prior to approval. crOMMENTS: 0114- U -- flit-L ?,)/< ( x,19 -. 2 - -A ' 16/ C, InsienVot.r:L. Date: ` .2/15, $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: l� ki.W. 9.3 INSPECTION RECORD `7 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ref 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -360 Proict:. _ b 60 Type of Inspection: / Ads /2 MI r Date Called: pecial Instructions: Date Wanted: C / • . ._ �p^� Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 24 4: (.1/C4/ ,'2x i % Insp t 67,04/1/4me,67./ 1 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: e:ue?�..JL.6 tw' '•1Y'Y%!f' ws- �h.,E.�.+r� w ':••• •5- •• .• - •••• .NP -[e. -.— s. • 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit lracc PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3j67 Project: but-0-5 f Q Type of Inspection: / qd t S / o ( Date Called: Special Instructions: Date Wanted: e.nr a Requester: Phone No: roved per applicable codes. LJ Corrections required prior to approval. Q COMMENTS: n 6/4 - AC -Cz-/7 I L t c772 k' dv,If Insp c,!`G DateFibM n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit (L6 -oL43 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 00 2 4 ra pci O Type of Inspection: �00 Address : 31 5- 1'o sr- Date Called: Special Instructions: Date Wanted: f.,/ 5 a r p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0-4‹. - 2 OrekGa0o42 �{ /HD 3/0 Inspector: gthh\fec Ioate / 3/c LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: bate: 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION x- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 tc °'g-x'13 Project: - ! �_... x411 0 Type of Inspection: 70D Address: Av. Date Called: Special Instructions: Date Wanted: t3 /1 / a.m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: e A fL fai2f K 5-rv$5 01.4'!'E uuK., Kmti roan o)11 tiFKc Ni0E-P Inspector: Date: n1rj'Gv El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: E MEMORANDUM angrneers tore sustainable future' R. J To: Kathy Craft From: Jennifer Ferguson Craft Architects PLLC 2111 Third Avenue r f c Seattle, WA 98121 (206) 720 -7001 Fax: (206) 720 -2949 ❑ Record of Telephone Conversation on kathy@craftarchitects.com ❑Mail Original Project: TOCAnnex Project #: 207C7401 Subject: Fault Current Calcs January 28, 2008 Page lof1 BUlm , 13109 Amps 3P C111.-raq 12s nsn. 14238 Amps 3P 18860 Amps 3P 19338 Amps 3P TARS FILE COPY Document2 a.AAI 19980 Amps 31. B.F.FI. — 21326 Amps 3P 112413-31.1 8245 Amps 3P rfi11 11635 Amps 3P i -FEL1 84.61.1 15889 Amps 31. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR - 4 2008 ity Of Tukwila B ILDIN D . ION nAisv BATS. 21326 Amps 3P 4580 Amps 31. N B ' _ B.1TLFlI 15889 Amps 3P B:.wsl 40000 Amps 3P JAN 2 9 2008 Seattle • Portland • Sacremenla • San Francisca • Los Angeles • Irvine Lase 22850 Amps 3P sml 9241 Amps 31. INCOMPLETE "R# SLOB- a+3 SW Was dlgten St. Suite 203 T. S&1.221.0280 F. 503!14.1S74 Portland, OR 9774 -1040 tmrnsv.glntaaclase 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Proj Address wells Fargo Bank - CV Operations Date 1/10/2008 6855 S. 180th street For Building Department Use Tukwila, Washington 98188 Name: Craft Architects Appl. Name 1932 First Avenue, Seattle WA98101 Appl. Phone (206) 720 -7001 Project Description ❑ Plans Included requirements. New ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) Efficacy > 60 lumens/W ❑ Controlled by motion Sensor ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lis~htin Wattage Tradable Locations D Description p Allowed Watts A Area (ft2), perimeter A Allowed Watts Uncovered Parking and drives P Parking Lot and Drive Lanes 0 0.15 W /ft2 6 68453.0 1 10268.0 Tradable Proposed Lighting Wattage Total Allowed Watts 10268.0 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Number of Watts/ Watts Location Fixture Description Fixtures Fixture Proposed Open Parking 400W, Pulse Start Metal Halide 21 455.0 9555.0 otal Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts 9555.0 ---------- lowed Watts Area (ft2), perimeter Allowed Watts Non - Tradable Locations De tP�lo �rr� ENV_ 1 •1 -r ft2 or per If (If) or # of items x ft2 (or x If) NFPA 70 — �RCC k.,.•O — A ')flfR 1 Non - Tradable Proposed Lighting attage i Q Citv Of Tukwila Number of Watts/ Watts Location Fix re Des on Fixtures Fixture Proposed 13 IL) NG D sIO,11.__I roposed Watts may not exceed Allowed Watts for Category FILE COpy EzO8 0H3 RECEIVED JAN 11 2008 PERMIT CENTER otal Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts 9555.0 ---------- lowed Watts Area (ft2), perimeter Allowed Watts Non - Tradable Locations De tP�lo �rr� ENV_ 1 •1 -r ft2 or per If (If) or # of items x ft2 (or x If) NFPA 70 — �RCC k.,.•O — A ')flfR 1 Non - Tradable Proposed Lighting attage i Q Citv Of Tukwila Number of Watts/ Watts Location Fix re Des on Fixtures Fixture Proposed 13 IL) NG D sIO,11.__I roposed Watts may not exceed Allowed Watts for Category FILE COpy EzO8 0H3 RECEIVED JAN 11 2008 PERMIT CENTER Non - Tradable Proposed Lighting attage i Q Citv Of Tukwila Number of Watts/ Watts Location Fix re Des on Fixtures Fixture Proposed 13 IL) NG D sIO,11.__I roposed Watts may not exceed Allowed Watts for Category FILE COpy EzO8 0H3 RECEIVED JAN 11 2008 PERMIT CENTER roposed Watts may not exceed Allowed Watts for Category FILE COpy EzO8 0H3 RECEIVED JAN 11 2008 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft2 Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft2 Stairways 1.0 W /ftz Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W/ft2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ftz Street frontage for vehicle sales lots in addition to "open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W /ftz for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/ft2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/ft2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ftz Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address wells Fargo Bank - CV operations Date 1/10/2008 6855 S. 180th Street For Building Department Use Tukwila, Washington 98188 Applicant Name: craft Architects Applicant Address: 1932 First Avenue, Seattle WA98101 Applicant Phone: (206) 720 -7001 Project Description ❑ Plans Included requirements. 4 New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 62.0 • No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area First Floor Fluorescent Downlight office 1.00 13000.0 13000.0 Fluorescent 2' x 4' Indirect / Direct Troffer 31 62.0 1922.0 First Floor Fluorescent 4' Strip Fixture 9 62.0 558.0 First Floor Metal 'Halide Garage Fixture 2 455.0 ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 13000.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed First Floor Fluorescent Downlight 10 26.0 260.0 First Floor Fluorescent 2' x 4' Indirect / Direct Troffer 31 62.0 1922.0 First Floor Fluorescent 4' Strip Fixture 9 62.0 558.0 First Floor Metal 'Halide Garage Fixture 2 455.0 910.0 First Floor Fluorescent 4' Indirect / Direct Linear Fixture 30 62.0 1860.0 First Floor Fluorescent 8' Indirect / Direct Linear Fixture 39 124.0 4836.0 First Floor Fluorescent 4' Vanity Fixture 2 32.0 64.0 First Floor Fluorescent 2' Vanity Fixture 1 22.0 22.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 10432.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington Slate Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 .' Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)57 •t1 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia, assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall•` 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Wells Fargo Bank - CV Operations Date 1/10/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E0.1, E3.0 yes 1513.2 Area controls Maximum limit per switch E3.0 n. a . 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a . vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w /backup Indicate location E0.1 yes (b) photocell. Indicate location E0.1 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E0.1 yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E0.1 yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning E3.0 EXIT SIGNS (Section 1514) yes I 1514 'Max. watts 'Indicate watts for each exit sign 1E0.1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E0.1 yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E0.1 MOTORS (Section 1511) Yes I 1511 JElec motor efficiency'MECH -MOT or Equipment Schedule with hp, rpm, efficiency Imo .1 I TRANSFORMERS (Section 1540) n.a. I 1540 (Transformers 'Indicate size and efficiency 1E6.0 I If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energ Code Com fiance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space. enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry /exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas. as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100.000 ft 2. 1513.3 Daylight Zone Control: All daylighted zones. as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant - sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety. security. or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5.000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings. all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours. if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch. or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). C a r c h i t e c t s August 13, 2008 Bob Benedicto, Building Official City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Re: Wells Fargo CV Operations Permit # EL08 -043 Project #: 746.00 Dear Mr. Benedicto: AUG 14X08 LOMMUNITY We received written notice from Ms. Jennifer Marshall dated July 29, 2008 stating our permit application for #EL08 -043 was approaching 180 days without a final inspection scheduled. See attached copy of letter. My understanding is there have been inspections on the project regarding electrical work, but the final inspection is still several months away. We were able to obtain our building permit #D07 -452 the week of August 3, 2008 and the contractor is now moving forward with the project. I believe the electrical permit was approved and issued back in March 2008. The final inspection has not been asked for because the contractor has been limited in the amount of work that they could perform without a building permit. We would like to request an extension of 180 days for the referenced permit application at this time. If you have any questions regarding our permit application #EL08 -043 please feel free to contact me at 206.720.7001 or cthomecraftarchitects.com. Sincerely, Chris Thome, AIA, NCARB Senior Project Manager 1932 First Avenue, Suite 408, Seattle, Washington 98101 Phone 206.720.7001 Fax 206.720.2949 07 -29 -2008 City of f Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director JESSICA BRADLEY 1932 FIRST AVE SUITE 408 SEATTLE WA 98101 RE: Permit No. EL08 -043 6815 S 180 ST TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 09/13/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall t Technician xc: Permit File No. ELO8 -043 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 January 18, 2008 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Jessica Bradley 1932 First Avenue, Suite 408 Seattle, WA 98101 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -043 Wells Fargo — 6855 South 180th Street Dear Ms. Bradley, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 11, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide fault current and load calculations. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: EL08 -043 P:\Permit Center\Incomplete Letters \2008 \EL08 -043 Incomplete Ltr # 1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -043 DATE: 01 -29 -08 PROJECT NAME: WELLS FARGO SITE ADDRESS: »D L S 180 ST Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMFNTC• Bun r g-Division Public Works Fire Prevention Structural Planning Division n Permit Coordinator ii DETERMINATION OF COMPLETENESS: (Tues., Thurs Complete Comments: Incomplete u DUE DATE: 01 -31 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAttED: Departments determined incomplete; Bldg (4 Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route 7 Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: d DUE DATE: 02 -28 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 PLANpREVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -043 DATE: 01 -11 -08 PROJECT NAME: WELLS FARGO SITE ADDRESS: 6855 S 180 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPAR MENT : leo B ilding Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 01 -17 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: !� I a U'DV q LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg (yJ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: n DUE DATE: 02 -14 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail,, fax, etc. Date: 1'2� 09 Plan Check/Permit Number: EL08-043 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: WELLS FARGO Project Address: 6855 South 180th Street Contact Person: Jessica Bradley Summary of Revision: Phone Number: RVVIStb tAUL* cUl 1 CAlg 7-DJO 72p 70D •r.twtu 1KW1lA .IAN 2 9 7000 -`tTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of rev's Received at the City of Tukwila Permit Center by: ❑ Entered in Permits Plus on \applications \forms - applications on line \revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Election or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License KIRBYEI077BN Licensee Name KIRBY ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601433048 Ind. Ins. Account Id Business Type CORPORATION Address 1 4826 B ST NW STE 101 Address 2 City AUBURN County KING State WA Zip 98001 Phone 2538592000 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/15/1993 Expiration Date 1/13/2009 Suspend Date Separation Date Parent Company Previous License KIRBYE *101QE Next License Associated License KIRBYDE962LZ Master Electrician Information License KIRBYDE962LZ Name KIRBY, DOUGLAS E Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date KIRBY, DOUGLAS E 01/01/1980 KIRBY, SHANNON 01/01/1980 • Bond Information i Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= KIRBYEI077BN 03/17/2008 ECSS, LIGHTING DISTRIBUTION & EQUIPMENT POWER DEVICES REFERENCE SYMBOLS SYMBOL • a 0 Q porameassal PTA 3c PTA 3A DESCRIPTION RECESSED LENSED LUMINAIRE (SIZE /SHAPE VARIES) RECESSED PARABOLIC LUMINAIRE (SIZE /SHAPE VARIES) SHADING OF ANY LUMINAIRE INDICATES CONNECTION TO EMERGENCY POWER SOURCE PER CIRCUITING INDICATED SUSPENDED LUMINARE (SIZE /SHAPE VARIES) POINT SOURCE - SURFACE, RECESSED CEILING MTD, FLOOR OR GRADE MOUNTED BOLLARD WALLWASH - SURFACE, RECESSED CEILING MTD. RECESSED WALL POINT SOURCE WRAP - AROUND TYPE FLUORESCENT TRACK LIGHTING WITH HEADS AS INDICATED, ADJUSTABLE POINT SOURCE - SURFACE CEILING, RECESSED CEILING MOUNTED, WALL WASH - SURFACE, RECESSED CEILING MTD, WALL SCONCE WALL MOUNTED FLOOD, POSSIBLY AIMABLE ILLUMINATED EXIT SIGN, SHADED QUADRANT INDICATES FACES, ARROWS AS SHOWN POLE MOUNTED LUMINAIRE- SINGLE OR DUAL HEAD POLE TOP MOUNTED LUMINAIRE "FOOT" INDICATES WALL MOUNTED LUMINAIRE FLUORESCENT STRIPLIGHT - POWER FEED SECTION, FEED THROUGH SECTION. LENGTH AS SHOWN. UNDERCABINET FLUORESCENT STRIPLIGHT FLUSH GRADE POINT SOURCE GARAGE LIGHTING LUMINAIRE WITH CUTOFF LOUVERS LUMINAIRE MARKING CONVENTION LEGEND: PTA = LUMINAIRE TYPE IDENTIFICATION. SEE LUMINAIRE SCHEDULE, 3c = CIRCUIT NUMBER VIA LOCAL SWITCH (LOWERCASE LLI11R) THAT SERVES THE LUMINAARE, 3A = CIRCUIT NUMBER /UPPERCASE LETTER COMBINATION INDICATES LOW VOLTAGE RELAY OR LIGHTING CONTACTOR THAT SERVES THE LUMINAIRE SWITCHING CONTROLS SYMBOL DESCRIPTION So S2 S s4 ;c D Srs sv sr sOR, PC 1-O EPO LCP ? SINGLE POLE SWITCH (SUPERSCRIPT DENOTES SIMILARLY MARKED LUMINAIRES CONTROLLED TOGETHER) TWO POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH KEY OPERATED SWITCH DIMMER SWITCH, NUMBER INDICATES WATTAGE RATING. IF NOT SHOWN THEN EQUAL TO LOAD. DIMMER SWITCH UNDER SEPARATE COVERPLATE TIMER SWITCH LOW VOLTAGE MOMENTARY CONTACT SWITCH, UPPER CASE LETTER SUPERSCRIPT INDICATES CONNECTION TO LOW VOLTAGE RELAY CONTROLLING SIMILARLY MARKED LUMINAIRES. EXPLOSION PROOF' SWITCH WEATHERPROOF SWITCH LINE VOLTAGE, VARIABLE SPEED FAN CONTROL SWITCH, PROVIDED BY DIV. 15, INSTALLED BY DIV, 16, LOCATE ADJACENT TO ADJACENT TO LIGHT SWITCHES. MOTOR -RATED THERMAL OVERLOAD SWITCH LIGHTING CONTROL OVERIDE SWITCH, SEQ. NUMBER PHOTOCELL EQUIPMENT OPERATOR PUSH BUTTON STATION, PROVIDED WITH EQUIPMENT, INSTALLED AND CONNECTED BY DIV. 16, UON, PUSHBUTTON OR PUSHBUTTONS, BY DIV. 16 TIME CLOCK OCCUPANCY SENSOR - WALL MOUNTED 360 DEGREE OCCUPANCY SENSOR - CEILING MTD. 180 DEGREE OCCUPANCY SENSOR - CEILING MTD, CORRIDOR /AISLE OCCUPANCY SENSOR - CEILING MOUNTED COMBINATION OCCUPANCY SENSOR & WALL SWITCH. EMERGENCY POWER OFF, HEAVY -DUTY, OIL -TIGHT RED MUSHROOM -HEAD PUSHBUTTON W/ GUARD, UGHTING CONTROL PANEL AND ASSOCIATED COMPONENTS. PROVIDE 120V OR 277V CONTROL POWER AS REQUIRED OR AS INDICATED. REMOTE MOUNTED LINE TO LOW - VOLTAGE FUSED TRANSFORMER, CONCEAL FROM VIEW, SYMBOL DESCRIPTION BRANCH CIRCUIT PANELBOARDS, SURFACE AND RECESS MOUNTED, SOLID= 120/280V, HATCHED= 277/480V, DASHED EQUIP, = FUTURE MOTOR CONTROL CENTER W/ CODE CLEARANCES SHOWN, DASHED EQUIP. = FUTURE TRANSFORMER WITH CODE CLEARANCES SHOWN SERVICE AND /OR DISTRIBUTION EQUIPMENT WITH CODE CLEARANCES SHOWN CONNECTION TO MOTOR PROVIDED BY OTHERS CONNECTION TO DIV. 15 FURNISHED VARIABLE FREQUENCY DRIVE WITH INTEGRAL DISCONNECT DIV. 16 TO INSTALL VFD EQUIPMENT DISCONNECT SWITCH, SIZE AS NOTED OR IF NOT SHOWN SIZE PER CONNECTED MOTOR SIZE AND MOTOR DISCONNECT SCHEDULE FUSED DISCONNECT SWITCH, SIZE AS NOTED. SIZE FUSE PER MANUFACTURER'S RECOMMENDATIONS ENCLOSED CIRCUIT BREAKER DISCONNECT SWITCH, TRIP SIZE AS NOTED, DISCONNECT W/ MAGNETIC MOTOR STARTER (CONOLLER) OR CZE PER D. NEMAOSIZE # R.MI IMUM. MAGNETIC MOTOR STARTER (CONTROLLER) OR CONTACTOR, SIZE PER LOAD SERVED, NEMA SIZE #1 MINIMUM. DIV. 16 CONNECTION TO EQUIPMENT PROVIDED BY OTHERS. SHADED = ON ALT. POWER SOURCE NOTED DIV, 16 CONNECTION TO EQUIPMENT WITH INTEGRAL DISCONNECT THAT IS PROVIDED BY OTHERS, SHADED = ON ALT, POWER SOURCE NOTED EQUIPMENT OR TERMINAL ENCLOSURE AS NOTED, SURFACE AND RECESS MOUNTED BUILDING GROUND BUS, SEE DETAILS DAMPER MOTOR BUSWAY RISER BUSWAY STAB -IN TYPE CIRCUIT BREAKER OR FUSE DISCONNECT. SIZE AS NOTED, DIAGRAMS SYMBOL DESCRIPTION r� L EIA 10 i0 HAND /OFF /AUTO SWITCH SWITCH FIELD INSTALLED CONTROL CIRCUIT WIRING TO DESTINATION SHOWN, U,O,N, OVERLOADS NORMALLY CLOSED CONTACTOR OR RELAY CONTACTS NORMALLY OPEN CONTACTOR OR RELAY CONTACTS BUS DUCT BUS BAR BATTERY GENERAL RESISTOR CONNECTOR, FEMALE AND MALE RESPECTIVELY PIPE GROUND CONTACTOR COIL RELAY COIL LIGHTNING SURGE ARRESTOR D= DISTRIBUTION CLASS I = INTERMEDIATE CLASS TRANSIENT VOLTAGE SURGE SUPPRESSOR CURRENT TRANSFORMER POTENTIAL TRANSFORMER NORMALLY OPEN PUSH BUTTON NORMALLY CLOSED PUSH BUTTON FUSED VOLTAGE SENSE LEADS METER: POWER FACTOR METER: KILOWATT HOUR UTILITY CO, APPROVED SOCKET WITH METER INSTALLED. SQUARE = REMOTE MOUNTED DIGITAL METER UNIT, REFER TO SPECIFICATIONS, CURRENT TRANSFORMER SHORTING TERMINAL BLOCK. TERMINAL FOR FIELD INStTALLED, TYPE LED D INDICATOR T BR LIGHT, PUSH ELLLOW TEST, WHITE DELTA CONNECTION GROUNDED WYE CONNECTION CONNECTION TO GROUND CIRCUIT BREAKER, WITH TRIP & FRAME AMPERE RATING FUSED SWITCH, WITH FUSE AND SWITCH AMPERE RATING INDIVIDUALLY MOUNTED CIRCUIT BREAKER CIRCUIT BREAKER, MEDIUM VOLTAGE, DRAWOUT DRAWOUT CIRCUIT BREAKER GROUND FAULT TRIP UNIT BELL ALARM TRIP MODULE CONTACTS SHUNT TRIP UNIT, 120VAC OR VOLTAGE AS NOTED MONITORING COMMUNICATION MODULE INTEGRAL AMMETER DISPLAY KEY INTERLOCK MECHANICAL INTERLOCK CAPACITOR, POWER FACTOR CORRECTION, SIZE IN KVAR GENERATOR FUSE, HOLDER & PULLER CONNECTION TO DIV, 15 CHILLER (+0 SOLENOID SYM BOL )11 40 40 0 40 44 0 40 L5 -15R AB GFI WP +42" 0 0)C-1; OIt Qi lr' KcZ tP 9v, DESCRIPTION SIMPLEX RECEPTACLE - WALL, CEILING, UPS POWER DUPLEX RECEPTACLE - WALL, CEILING, UPS POWER DOUBLE DUPLEX RECEPTACLE - WALL, CLG, UPS PO SPECIAL PURPOSE RECEPTACLE -WALL, CEILING UPS POWER; NEMA CONFIGURATION AS NOTED RECEPTACLE TYPE SHOWN -WALL -ABOVE COUNTER BACKSPLASH. SEE ARCHITECTURAL DRAWINGS, DUPLEX RECEPTACLE - WALL - GENERATOR POWER COMBINATION SWITCH /DUPLEX RECEPTACLE DUPLEX RECEPTACLE - WALL - WITH INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER RECEPT. TYPE SHOWN W/ WEATHERPROOF COVER AND INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER RECEPT. TYPE SHOWN AT SPECIAL HEIGHT WALL MOUNTED ELECTRICAL CONNECTION TO ELECTRIFIED FURNITURE. PROVIDE 8 WIRES (4 HOTS, 1 DEDICATED NEUTRAL, 1 COMMON NEUTRAL, 1 ISOLATED GROUND) NEUTRALS TO BE #10 AWG. USE LIQUID -TIGHT FLEX, CLOCK HANGER RECEPTACLE FLUSH FLOOR BOX DEVICE - DEVICE TYPE PER SYMBOLS ABOVE PEDESTAL FLOOR DEVICE - DEVICE TYPE PER SYMBOLS ABOVE POKE THRU UNIT WITH DUPLEX RECEPTACLE FLUSH, PEDESTAL MOUNTED. POKE THRU UNIT WITH DOUBLE DUPLEX RECEPTACLE - FLUSH, PEDESTAL MOUNTED. COMBO POKE THRU UNIT WITH DUPLEX RECEPTACLE AND TELEPHONE OUTLET - FLUSH, PEDESTAL MOUNTED. MULTI - SERVICE FLOOR BOX CAST IN CONC. OR IN RAISED FLOOR - SEE ARCH DWGS; WITH RECEPTACLES & SIGNAL OUTLETS AS NOTED, POKE THRU UNIT WITH JUNCTION BOX. RACEWAY COMPONENTS RC -700 SERIES, TELE /POWER POLE, POWER POLE TELE /POWER POLE WITH WHIP CONNECTION TO ELECTRIFIED FURNITURE TWO -PIECE SURFACE METAL RACEWAY WITH RECEPTACLES AS NOTED, LENGTH AS INDICATED ON THE DRAWINGS AND WITH ALL FITTINGS AS REQUIRED. TWO OR THREE COMPARTMENT SURFACE METAL RACEWAY WITH RECEPTACLES AND OUTLETS AS INDICATED, LENGTH AS INDICATED ON THE DRAWINGS. PROVIDE ALL FITTINGS AS REQUIRED, SIGNAL DEVICES SYMBOL DESCRIPTION 1 1 4w d TERMINAL /MOUNTING BOARD, 8' HIGH X WIDTH AS SHOWN, FIRE TREATED. SIGNAL SYSTEM EQUIPMENT ENCLOSURES AS NOTED - SURFACE, RECESSED MOUNTED ROUGALHLIN FOR COMBO TELEPHONE /DATA OUTLET ROUGH -IN FOR TELEPHONE OUTLET - WALL, W = USE HIGHER MOUNTING HEIGHT PER MOUNTING HT, DETAIL ROUGH -IN FOR DATA OUTLET - WALL PUSHBUTTON OR PUSHBUTTONS ROUGH -IN FOR RF COAX CABLE OUTLET (TV, ETC.) ROUGH -IN FOR COMBINATION RF COAX CABLE AND DATA OUTLET ER SYMBOL (12) EQUIP NAME DESCRIPTION SHEET NOTE REFERENCE BRANCH CIRCUIT OR FEEDER NOMINAL AMPACITY & TYPE; REFER TO BRANCH CIRCUIT AND FEEDER SCHEDULES FOR WIRE AND CONDUIT SIZES & QTY. REFER TO DETAIL NO. ON DRAWING INDICATED NOT ALL DETAIL REFERENCES ARE SHOWN. ALL DETAILS APPLY TO ALL APPLICABLE SITUATIONS, UON, ELEVATION TAG: REFER TO ELEVATION NUMBER ON DRAWING INDICATED SECTION TAG: REFER TO SECTION NUMBER ON DRAWING INDICATED KITCHEN EQUIPMENT REFERENCE, REFER TO KITCHEN EQUIPMENT SCHEDULE MECHANICAL EQUIPMENT IDENTIFICATION TAG EQUIPMENT BY OTHERS IDENTIFICATION TAG WIRING SYMBOL DESCRIPTION 410■111111, 021111•111 (09t.• X X X T ® MV — G — GC — fN L1A -1,3 HD1A nn.nn w UZI WIRING CONCEALED IN CEILING OR WALL. LINE WEIGHT TOP TO BOTTOM= NEW, EXISTING TO REMAIN, FUTURE WIRING CONCEALED IN FLOOR OR UNDER GRADE OR ROUTED IN CEILING SPACE OF FLOOR BELOW. LINE WEIGHT TOP TO BOTTOM= NEW, EXISTING TO REMAIN, FUTURE EXISTING WIRING TO BE REMOVED TELEPHONE SYSTEM CONDUIT MEDIUM VOLTAGE CONDUIT BARE GROUNDING GRID OR CONDUCTORS, UON. GROUNDING CONDUCTOR(S) ROUTED IN CODE SIZED CONDUIT, UON, STROKES INDICATE QUANTITY OF #12 AWG, CONDUCTORS, UON, NOTE: WIRING STROKES FOR 20A BRANCH CIRCUITS ARE NOT SHOWN ON DRAWINGS. CONTRACTOR SHALL USE INFORMATION IN PANEL AND BRANCH CIRCUIT SCHEDULES TO PROVIDE REQUIRED CIRCUITING, GROUND HOT NEUTRAL HOME RUN WIRING TO INDICATED DESTINATION, 3/4 "C. MIN. OR AS OTHERWISE NOTED, CONTRACTOR SHALL USE CIRCUIT SIZES NOTED IN RESPECTIVE SCHEDULES AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT SCHEDULES. CONDUIT RUN TURNED UP THROUGH FLOOR OR CEILING. CORE & FIREPROOF AS REQUIRED, CONDUIT RUN TURNED DOWN THROUGH FLOOR OR CEILING. CORE & FIREPROOF AS REQUIRED, CONDUIT STUBBED OUT AT LOCATION SHOWN. PROVIDE INSULATED BUSHING & PULLROPE, TELEPHONE /DATA SLEEVE THROUGH WALL, ABOVE CEILING. EXTEND TO ACCESSIBLE TILE CLG. BOTH SIDES, TERMINATE WITH BUSHINGS, (1) 1,25" CO UON, COORDINATE LOCATIONS WITH CABLE INSTALLER(S) PRIOR TO ROUGH -IN, BASKET TYPE CABLE TRAY WITH 90 DEGREE ELBOW SHOWN LADDER TYPE CABLE TRAY WITH 90 DEGREE ELBOW SHOWN JUNCTION BOXES, WALL, CEILING AND FLUSH FLOOR MOUNTED. 4" SO, BOX MIN., LARGER IF REQUIRED WIRING EXTENSION POINT - CONDUIT TO MC CABLE OR MANUFACTURED WIRING SYSTEM J- BOX ABOVE ACCESSIBLE CEILINGS AREAS, OR EXTEND CONDUIT & WIRE IN EXPOSED OR "HARD" CEILING AREAS. SHADED= ON ALT. POWER SOURCE (EM;.RG,UPS,ETC.) PULL BOX, MIN, SIZE PER NEC,, UON. FLEXIBLE CONDUIT CONNECTION POWER CONNECTION TO DIV 15 FIRE /SMOKE DAMPER, REFER TO FSD CONNECTION DETAIL IF NOT SHOWN GROUND ROD CONNECTION GROUND ROD CONNECTION WITH TEST WELL BOX LIGHTNING SYSTEM AIR TERMINAL GROUNDING SYSTEM SYMBOL DESCRIPTION —GC • VI Z. WIMI6191, • BARE GROUNDING GRID OR CONDUCTORS, UON. GROUNDING CONDUCTOR(S) ROUTED IN CODE SIZED CONDUIT, UON, GROUND GRID BOND POINT GROUND GRID BOND POINT - MECHANICAL CONNECTION GROUND GRID BOND POINT - EXOTHERMIC WELD CONNECTION 24" GROUND BAR 60" GROUND BAR GROUND ROD LOCATION GROUND ROD IN TEST WELL SEPARATED PERMIT REQUIRE dMechanical ❑ Electrical /Iumbing I. Gas Piping City of Tukvvila BUILDING DIVISION APPROVED Pt.^.rlC .^r;n t;^CCIFICAr1'JPT p''' ' �r CI;ANGED, MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING 0' 7:::AL, ALI WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS T_YllECT TO FIELD INSPECTIONS. EXAMPLES / LEGEND MCC— H M 1 A DP— U L D 1 A XFR— H L 1 A SWBD— M H SN 1 A PNL— E H K 2 T T POWER ADDN'L SYSTEM DESIG. DESIG. EQUIP. SYSTEM FLOOR TYPE VOLTAGE SEQ. LETTERS SUB SW8D SWGR DP PNL ATS BIATS MTS XFR UTX MCC CB FSW DSW EQUIPMENT TYPE - UNIT SUBSTATION - SWITCHBOARD - SWITCHGEAR - DISTRIBUTION PANEL - BRANCH PANEL - AUTOMATIC TRANSFER SWITCH - BYPASS ISOLATION ATS - MANUAL TRANSFER SWITCH - TRANSFORMER - UTILITY MAIN TRANSFORMER - MOTOR CONTROL CENTER - ENCLOSED CIRCUIT BREAKER - FUSED DISCONNECT SWITCH - NON -FUSED DISCONNECT SW. POWER SYSTEM BLANK - NORMAL LOADS M - MAIN UTILITY SERVICE E - EMERGENCY POWER (Life Safety) S - STANDBY POWER U - UNINTERRUPTIBLE POWER (UPS) C - CRITICAL POWER (Hospital) Q - EQUIPMENT POWER (Hospital) S - LIFE SAFE IY POWER (Hospital) VOLTAGE H - 480/277 VOLT L - 208/120 VOLT MV - MEDIUM VOLTAGE (E) (F) (R) (RL) AB ACU AC A, AMP AF AFF AEG AIC AL ALC AS AT ATS AUTO AUX AWG BAT BG BRKR C CAB CB CFM CKT CLG CO CPT CT CU EXISTING TO REMAIN FUTURE EXISTING TO BE REMOVED EXISTING TO BE RELOCATED ABOVE COUNTER BACKSPLASH AIR CONDITIONING UNIT ALTERNATING CURRENT AMPERES AMPERE (RATED) FUSE OR CB FRAME ABOVE FINISHED FLOOR ABOVE FINISHED GRADE EQUIPMENT SHORT CIRCUIT INTERRUPT RATING (RMS SYM, AMPS) ALUMINUM (ALLOY) AUTOMATIC LIGHTING CONTROL AMPERE (RATED) SWITCH CIRCUIT BRKR TRIP SETTING (AMPS) AUTOMATIC TRANSFER SWITCH AUTOMATIC AUXILIARY AMERICAN WIRE GAUGE BATTERY BELOW GRADE CIRCUIT BREAKER CONDUIT (CIRCULAR RACEWAY) CABINET CIRCUIT BREAKER CUBIC FEET PER MINUTE CIRCUIT CEILING CONDUIT ONLY CONTROL POWER TRANSFORMER CURRENT TRANSFORMER COPPER DC DIRECT CURRENT DISC DISCONNECT DIA DIAMETER DIV DIVISION DP DISTRIBUTION PANEL DPDT DOUBLE POLE DOUBLE THROW DPST DOUBLE POLE SINGLE THROW DWG DRAWING E,EMERG EMERGENCY EF EXHAUST FAN EMT ENCL EO EOL EWC EWH FA FAA FBO FC FF FLA FLEX FPB FSD FW FU GEN GFI GND GRAP GRC HLO HP HPF HTR HZ IES IBC ID IG IMC ELECTRICAL METALLIC TUBING ENCLOSURE ELECTRICALLY OPERATED END OF LINE ELECTRIC WATER COOLER ELECTRIC WATER HEATER FIRE ALARM FIRE ALARM ANNUNCIATOR FURNISHED BY OTHERS FOOT CANDLES FLUSH FLOOR MOUNTED FULL LOAD AMPERES FLEXIBLE FAN POWERED BOX FIRE /SMOKE DAMPER FLUSH WALL MOUNTED FUSE GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND GENERATOR REMOTE ANNUNCIATOR PNL GALVANIZED RIGID STEEL CONDUIT HANDLE LOCK- ON(OFF) HORSEPOWER HIGH POWER FACTOR HEATER HERTZ (CYCLES PER SECOND) ILLUMINATING ENGINEERING SOCIETY INDIVIDUAL BRANCH CIRCUIT INSIDE DIAMETER ISOLATED GROUND INTERMEDIATE METAL CONDUIT KCMIL THOUSAND CIRCULAR MILS KO KNOCK OUT KW KILOWATTS KVA KILOVOLT- AMPERES LTG LIGHTING LCP LIGHTING CONTROL PANEL MAX MAXIMUM MCA MINIMUM CIRCUIT AMPERES MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUGS ONLY MO MANUAL OPERATOR MTD MOUNTED MTR MOTOR -N- NEUTRAL (GROUNDED CONDUCTOR) NC NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE -,NEG NEGATIVE NEMA NATIONAL ELECTRICAL MFGR'S ASSOC. NL NIGHT LIGHT (UNSWITCHED) NO NORMALLY OPEN NTS NOT TO SCALE NP NAMEPLATE OC ON CENTER OD OUTSIDE DIAMETER OFCI OWNER FURNISHED CONTRACTOR INSTALLED OF01 OWNER FURNISHED, OWNER INSTALLED OS OCCUPANCY SENSOR P POLE PB PUSHBUTTON PH, 0 PHASE PNL PANEL +,POS POSITIVE PRI PRIMARY REQD REQUIRED RNC RIGID NON- METALLIC CONDUIT (PVC) RS RAPID START RST REMOTE STATION TRANSMITTER S,A,D. SEE ARCHITECTURAL DRAWINGS SEC SECONDARY SN SHEET NOTE SOL SOLENOID SPDT SINGLE POLE DOUBLE THROW SPST SINGLE POLE SINGLE THROW SUB SUBSTATION SWBO SWITCHBOARD SWGR SWITCHGEAR TB TERMINAL BOARD TDC TIME DELAY CLOSING TDO TIME DELAY OPENING TEL TELEPHONE TYP TYPICAL UL UNDERWRITERS LAB UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY UTX UTILITY TRANSFORMER ✓ VOLTS VA VOLT- AMPERES VFD VARIABLE FREQUENCY DRIVE W WATT W/ WITH W/O WITHOUT WP WEATHERPROOF, SEE RECEPT, SYMBOL XFR TRANSFORMER XP EXPLOSION PROOF Z ZONE ", IN INCHES FT FEET O PHASE > GREATER THAN < LESS THAN 2 GREATER THAN OR EQUAL TO 1. NATIONAL ELECTRIC CODE VERSION USED: 2006 2, FIRE ALARM CODE VERSION USED: IFC 3, INTERNATIONAL BUILDING CODE VERSION USED: IBC LOCJ 4, AMERICANS WITH DISABILITIES ACT, (ADA) 5. WASHINGTON STATE ENERGY CODE 6. LIGHTING CRITERIA USED, BASED ON RECOMMENDED LEVELS BY ILLUMINATING ENGINEERING SOCIETY (IES) CORRIDORS - 10 FC OFFICES - 30 FC RESTROOMS - 10 FC 7, PARKING LOT & SECURITY LIGHTING CRITERIA, BASED ON THE OWNER'S REQUIREMENTS, THE UNIFORMITY OF THE SITE UGHTING IS DESIGNED TO A MAX /MIN RATIO OF 1:25 PARKING LOT - 2 FC BUILDING PERIMETER - 5 FC (20' OUT FROM BLDG) BUILDING EMTRANCE - 10 FC 8. LIGHTING CONTROLS: A. LOW VOLTAGE CONTROLS FOR SWEEP -OFF FUNCTIONS IN OFFICE AREAS, B, OCCUPANCY SENSORS IN CONFERENCE RMS, STORAGE ROOMS, RESTROOMS, SMALL OFFICES. C, PHOTOCELL ON & OFF- EXTERIOR LIGHTING 9, POWER DENSITY IN OFFICE AREAS: 6 WATTS /SQFT. 10. MAX. NUMBER OF WORKSTATIONS PER 20A CIRCUIT: 4 A, REFER TO DETAIL DRAWINGS FOR ADDITIONAL INFORMATION, ALL DETAILS APPLY FOR ALL APPLICABLE SITUATIONS WHETHER REFERENCED OR NOT, LION, REFER TO ARCHITECTURAL FLOOR PLANS, INTERIOR ELEVATIONS AND DETAIL DRAWINGS PRIOR TO ROUGH -IN FOR EXACT LOCATION OF RECEPTACLES, FLOOR BOXES AND OUTLETS. INFORM ENGINEER OF CONFLICTS. THE CIRCUITING SHOWN IS DIAGRAMMATIC. THE DRAFTING METHOD WHICH MOST SIMPLY CONVEYS THE CIRCUITING INTENT IS EMPLOYED. WHERE DEVICES OR EQUIPMENT ARE SHOWN UNCONNECTED; CONNECT (IN A MANNER CONSISTENT WITH THE MATERIALS AND METHODS INDICATED IN THE SPECIFICATIONS AND DRAWINGS) FROM THE WIRING EXTENSION POINT SHOWN TO EACH DEVICE, CONTRACTOR IS RESPONSIBLE TO REVIEW ARCHITECTURAL DRAWINGS TO CONFIRM CEILING TYPES IN ALL ROOMS (ACCESSIBLE, EXPOSED, OR "HARD ") AND TO USE THE APPROPRIATE WIRING METHOD FOR EACH TYPE. INSURE ALL J -BOXES ARE ACCESSIBLE AFTER ALL OTHER TRADE'S WORK IS COMPLETED, DO NOT LOCATE ANY J -BOXES ON "HARD" CEILINGS; ALL WIRING MUST BE ACCESSIBLE THROUGH DEVICE ONLY IN "DAISEY- CHAIN" METHOD OR WITH DEDICATED HOMERUNS TO EACH DEVICE. J- BOXES MAY BE LOCATED ABOVE OTHER TRADE'S ACCESS DOORS IF FEASIBLE AND DOES NOT INTERFERE WITH ACCESS. INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS. THESE DRAWINGS ARE DIAGRAMMATIC, zs E0,0 ELECTRICAL LEGEND E0.1 ELECTRICAL SCHEDULES E1.0 ELECTRICAL SITE PLAN E2,0 FIRST FLOOR PLAN - POWER & SIGNAL E2,2 ROOF PLAN - POWER E3.0 FIRST . FLOOR PLAN - LIGHTING E6.0 ELECTRICAL - ONE LINE DIAGRAM E7.0 ELECTRICAL - PANEL SCHEDULES E8.0 ELECTRICAL - DETAILS E8.1 ELECTRICAL - DETAILS FILE 90 Permit No.. (/Ots -0,13 Plar review approval is subject to errors an Approval of construction documents does r the violation of any adopted code or ordinal of approved Field Copy and conditions is ac Date:.? City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made too the Veis of Tukwila Building Division. NOTE: Revisions will require a new plan and may include additional plan review Public Works, Building Division PERMIT NUMBER 0P Ap _Date .212-1/D £LO8OM3 1 ()missions. 01 authorize :C s. Receipt owled'ged: AINOM110 FILE COP JAN 1 1 2008 i'L 'ti�ii I i`J f C I. PERMIT SET 05.31.07 Terminal Sales Building 1932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 206.72.0.2949 fax www.craftarchitects.com WELLS FARGO BANK Z CC 0 ca cr 0. CONSULTANT TUKWILA, WASHINGTON GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 T. 503.227.5280 P. 503.274 7674 www.ghunac.com Job No.: 207W2001 A Contact: J. FERGUSON r 9 engineers for a sustainable future- s. r SEAL EXPIRES 01/28/2009 Revisions: Sheet Title: ELECTRICAL LEGEND Date: Design: Drawn: 6/I/01 JXF JXF Project No: Approved: 207W2001A COPYRIGHT ©2007 GLUMAC L: \.LUU /— Jobs \YU /WLUU1A.gZ \Wt— LU1.tlwg UV Nov 'LUU/ — 2:46 pm JtG E: TOC Annex TAG DA GA HA KA LA1 LA2 MA1 MA2 SA SB1 SB2 SC SD1 SD2 SIZE/ DESCRIPTION RECESSED, OPEN REFLECTOR DOWNUGHT WITH 6" APERATURE. RECESSED, DIRECT /INDIRECT 2' X 4' LUMINAIRE SURFACE MOUNTED, 4' GENERAL PURPOSE STRIP LUMINAIRE CEILING MOUNTED, GARAGE FIXTURE WITH SILICONE GASKETING, EXTRUDED ALUMINUM HOUSING WITH ARCHITECTURAL CLASS I ANODIZING. SUSPENDED, LINEAR SEMI — INDIRECT 4' LUMINAIRE SUSPENDED, LINEAR SEMI — INDIRECT 8' LUMINAIRE WALL MOUNTED, 4' VANITY LUMINAIRE LUMINAIRE SCHEDULE LAMP INFORMATION WALL MOUNTED, 2' VANITY LUMINAIRE SINGLE HEAD, CUTOFF POLE MOUNTED LUMINAIRE. DIE CAST ALUMINUM HOUSING, ANODIZED ALUMINUM REFLECTOR AND TEMPERED GLASS LENS. DOUBLE HEAD, CUTOFF POLE MOUNTED LUMINAIRE. DIE CAST ALUMINUM HOUSING, ANODIZED ALUMINUM REFLECTOR AND TEMPERED GLASS LENS. DOUBLE HEAD, CUTOFF POLE MOUNTED LUMINAIRE WITH ROTATED OPTICS. TRIPLE HEAD, CUTOFF POLE MOUNTED LUMINAIRE WITH HEADS SEPARATED BY 90 DEGREES. TYPE QTY DESCRIPTION FLUO FLUO FLUO PSMH FLUO FLUO WALL MOUNTED, WIDE THROW AREA LUMINAIRE, DIE CAST ALUMINUM HOUSING. COMPLETELY SEALED AND GASKETED. SD3 X WALL MOUNTED, FORWARD THROW AREA LUMINAIRE, DIE CAST ALUMINUM HOUSING. COMPLETELY SEALED AND GASKETED. CUTOFF MINI— WALLPACK. UL LISTED FOR WET LOCATIONS. UNIVERSAL MOUNTED LED EXIT SIGN WITH GREEN LETTERS 1 2 2 1 2 FLUO FLUO PSMH PSMH PSMH PSMH MH MH FLUO LED 4 1 26W DTT 3500K, 80 + CRI F032 T8 3500K, 80 + CRI F032 T8 3500K, 80 + CRI 400W PULSE START METAL HAUDE 4000K, 75+ CRI F032 T8 3500K, 80 + CRI F032 T8 3500K, 80 + CRI 1 1 2 2 3 1 1 F032 T8 3500K, 80 + CRI FO17 T8 3500K, 80 + CRI 400W PULSE START METAL HAUDE 4000K, 75+ CRI 400W PULSE START METAL HAUDE 4000K, 75+ CRI 400W PULSE START METAL HAUDE 4000K, 75+ CRI 400W PULSE START METAL HAUDE 4000K, 75+ CRI 175W METAL HAUDE 4000K, 75+ CRI 175W METAL HAUDE 4000K, 75+ CRI BALLAST DESCRIPTION (1) 1 'mP ELECTRONIC LAST TOTAL VA (1) 2 -LAMP ELECTRONIC LAST (1) 2 —LAMP ELECTRONIC LAST (1) 1 —LAMP HIGH POWER FACTOR BALLAST (1) 2 —LAMP ELECTRONIC : LAST (1) 2 -LAMP ELECTRONIC : -' LAST 26 62 62 430 62 (1) —LAMP ELECTRONIC : LAST MANUFACTURER GOTHAM PORTFOLIO CATALOG NUMBER AF 1/26 DIT 6AR 120 GEB 10 C6126 E, 6251 LI VOLT 120 LITHONIA METALUX LITHONIA METALUX GARDCO 2AV G 232 MDR 120 GEB10IS 2 RDI 232 RP 120V EB81 120 C 232 120 GEB10IS SS 232 120V EB81 SCBEH19 Q 400PSMH 208 BLA 120 208 124 32 (1) LAMP ELECTRONIC LAST 22 (1) 1 —LAMP HIGH POWER FACTOR BALLAST 410 (2) 1 —LAMP HIGH POWER FACTOR BALLAST 820 (2) 1 —LAMP HIGH POWER FACTOR BALLAST 820 (3) 1 —LAMP HIGH POWER FACTOR BALLAST 1230 (1) 1 —LAMP HIGH POWER FACTOR BALLAST 205 (1) 1 —LAMP HIGH POWER FACTOR BALLAST 205 1 26W DTT 1 GREEN LED ELECTRONIC HIGH POWER FACTOR 120 V POWER SUPPLY 26 GENERAL NOTES: A. PRODUCT NUMBERS SHOWN ARE ASSOCIATED WITH THE FIRST MANUFACTURER USTED ON THE LUMINAIRE SCHEDULE FOR EACH LUMINAIRE TYPE. ALL OTHER LISTED MANUFACTURERS ARE APPROVED BUT MUST MEET ALL REQUIREMENTS OF SPECIFIED ITEM. CONTRACTOR TO SUBMIT CUTSHEETS OF ALTERNATE AND APPROVED MANUFACTURERS PRODUCT ALONG WITH CUTSHEETS OF SPECIFIED FIXTURE FOR REVIEW AND APPROVAL BY ENGINEER. C. CONTRACTOR IS : RESPONSIBLE TO VERIFY CEIUNG TYPE AND THICKNESS AND PROVIDE REQUIRED LUMINAIRE MOUNTING TRIMS & BRACKETS FOR ALL FIXTURE TYPES. D. CONTRACTOR IS RESPONSIBLE TO VERIFY SINGLE OR DOUBLE FACE AND MOUNTING OF EXIT SIGNS WITH LIGHTING PLANS AND ARCHITECTURAL CEILING PLANS AND PROVIDE WALL MOUNTING BRACKETS, CEILING MOUNTING BRACKETS AND /OR PENDANTS AS REQUIRED E. IN LOCATIONS WHERE DUCT WORK RUNS OVER THE TOP OF RECESSED LUMINAIRES, THE LUMINARIES AT THESE LOCATIONS WILL BE HORIZONTALLY SUPPORTED TO AVOID UNNECESSARY DUCT PENETRATIONS. LUMINAIRES ARE TO BE SUPPORTED BY THE CEIUNG SYSTEM OR BUILDING STRUCTURE ONLY. F. ALL SUSPENDED LINEAR LUMINAIRES TO BE EQUIPPED WITH WHITE POWER CHORD 3 PEERLESS COREUTE PEERLESS COREUTE 10 CRM 7232 WHR 120 GEB10 DCT LP835 F1/24" SCEP AZ WP2T82C120 AC 24" T1 CMET LITHONIA METALUX LITHONIA METALUX GARDCO GARDCO GARDCO GARDCO GARDCO GARDCO LTT1i0NIA UTHONIA 10 CRM 7232 WHR 120 GEB10 DCT LP835 F1/24" SCEP AZ WP2T82C120 AC 24" T1 CMET 120 120 WC 1 32 120 GEB10IS BC 132 120V EB81 WC 1 17 120 GEB10IS BC 117 120V EB81 EH19- 1- 4X- 400PSMH EH 19 — 2- 4X- 400PSMH EH 19- 2- 4X- 400PSMH EH19- 3 /90- 4X- 400PSMH RECESSED CEILING 120 RECESSED CEILING 120 SURFACE CEILING 208 SURFACE CEILING 208 208 101 WT 175MH SUSPENDED CEILING 208 101 FT 175MH SUSPENDED CEILING 208 TWAC -26DTT -120 208 SURFACE WALL 120 LE SERIES SURFACE WALL POLE AT 25' 120 POLE AT 25' POLE AT 25' POLE AT 25' SURFACE WALL SURFACE WALL WALL VARIES LUMINAIRE REMARKS: €1 1 REFER TO ARCHITECTURAL ELEVATIONS TO CONFIRM MOUNTING HEIGHTS. INFORM ENGINEER OF CONFUCTS. 21 SEE POLE DETAIL 2/E8.1. PROJECT: LOCATION: RELAY TOC ANNEX MAIN ELECTRICAL ROOM TAG NO. 1 2 3 4 5 6 7 PANEL NAME CKT. SL1A 38 SL1A 39 LIGHTING CONTROL PANEL SCHEDULE LCP-A LOAD DESCRIPTION CORRIDOR UGHTING OPEN OFFICE SWEEP SL1A SL1 A SL1A SL1 A to 41 37 35 2 4 OPEN OFFICE OPEN OFFICE OPEN OFFICE EXTERIOR UGHTING 12:OOAM 12:OOAM 12:OOAM 12:OOAM 12:OOAM ON /OFF CONTROL PROGRAMM NG LS PC —ON X X PC —OFF TC —ON TC OFF OS X X 11 9 07 12:09 PM REMARKS X X X X X X X X " SL1A 6 EXTERIOR LIGHTING 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 " 8 so " SL1A 7 EXTERIOR LIGHTING X X " 9 " SL1A 11 EXTERIOR LIGHTING X X " 13 " SL1 A 15 EXTERIOR LIGHTING X X " 17 " " SL1 B 57 EXTERIOR LIGHTING X X 59 " SPARE SPARE SPARE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE LEGEND: TC= TIME CLOCK, PC= PHOTOCELL, OS= OCCUPANCY SENSOR AUX. CONTACT, LS= LOCAL SWITCH GENERAL NOTES: A. SYSTEM IS DESIGNED AROUND PCI LITEKEEPER 32. B. SWEEP OFF TIME NOTED IS THE TIME TO START THE SWEEP, IT SHALL REOCCUR EVERY TWO HOURS UNTIL 4:OOAM C. PROVIDE 32 RELAY ENCLOSURE SIZE WITH 20 RELAYS INITIALLY REMARKS: I1� €21 REVIEWED FOR ...... CODE COMPLIANCE NFPA 70 - NEC 3` MAR - 4 2008 City Of Tukwila ILli DIVISION I[ i inai ''ia ' 5 H1)1 1 92s ` -irct Av' ":tie. 'I.., t 108 Sea-. 5:1A :F is 1 0 1 rfl(-). t2(1.?'li4.i1 p s °ie "I°i:h afti rc hi°tects.cca m z f2 IA _J o x CONSULTANT !20 SW i' asisiie °r „,i5'ss., Suitt:'` 00 ' Porthold, OR 07204 t a413 It'47 211<.a 1? 54)1,2741674 1. 207W2001A 1• J. FERGUSON w st inajI fafurl EXPIRES 01/28/2009 Revisions: 1 1.09.07 SITE RESUBMITTAL ELO fa■ Li 3 Sheet Title: ELECTRICAL SCHEDULES JAN 11 2008 CLi\ L , Date: II /Q/07 Design: JXI= Drawn: JI(F Project No: 207141200IA Approved: Sheet No: E0.1 COPYRIGHT©2007 GLUMAC L: \ -1UU /— Jobs \'LU /WLUU1A.g2 \WF— L1U.dwg U9 Nov 2UU/ — 2:4/ pm 5LU sCD `% .7.111.0 ow.. MHO f dIEBVIa OM SD1 SD1 SOUTH 180TH ST (1) 2 "C. SD1 SD1 SD1 SD1 SD1 (1) 4 "C. SD1 SD1 SD1 SD1 SD1 / O/ SD1 SD1 SD2 (1) 4 "C. SD2 SD2 NEW BUILDING PROPOSED TRANFORM LOCATION CP —A -12,13 SD1 SD1 SD1 SD1 O SD1 0 0 ELECTRICAL SERVICE RESPONSIBILITY \ TRENCHING &: BACKFILL PRIMARY CONDUITS SECONDARY CONDUIT PRIMARY CONDUCTORS SWB LINE SIDE SECONDARY CONDUCTORS TRANSFORMER (UTX) UTX PAD/ VAULT UTX CONNECTIONS PRIMARY GROUNDING CT ENCLOSURE CT's METER BASE METER METER GROUNDING SECONDARY CONDUCTORS NOTES: UTILITY CONTRACTOR CO. PROVIDES X X X X X x x x X x X X X X X UTILITY CONTACTS 1. CONTACT AND COORDINATE ALL REQUIREMENTS AND RESPONSIBILITIES WITH SERVING UTILITY COMPANIES PRIOR TO SUBMITTING BIDS 2. ALL SERVICE INSTALLATION WORK SHALL BE IN STRICT COMPLIANCE WITH THE REQUIREMENTS OF THE SERVING UTILITY. 3. GLUMAC HAS CONTACTED THE UTILITIES BUT HAS NOT RECEIVED IN WRITING THE FINAL REQUIREMENTS FROM THE POWER UTILITY, TELEPHONE: UTILITY OR THE CAN UTILITY. THESE DRAWINGS INDICATE OUR BEST ESTIMATION OF THEIR REQUIREMENTS. PRIOR TO ANY CONSTRUCTION CONTACT THE UTILITIES AND OBTAIN IN WRITING THEIR REQUIREMENTS TELEPHONE UTILITY CONTACT: QWEST PHONE: (206) 224- 1146 POWER UTILITY CONTACT: PUGET SOUND ENERGY 3130 S. 38TH STREET TACOMA, WASHINGTON 98409 PHONE: (425) 452 -1234 FAX: (253) 476-6007 CABLE T.V. UTILITY (CAR/ COMCAST PHONE: (800) 266 ®2278 CONTACT: 96) SD1 'v \ ♦ • \ SB2 SD1 EXISTING BUILDING ( TOC) SD1 SD1 SD1 SD1 GENERAL NOTES A. REFER TO ELECTRICAL DETAIL DRAWINGS FOR ADDITIONAL INFORMATION. ALL DETAILS APPLY \ FOR APPLICABLE SITUATIONS WHETHER REFERENCED ON THE PLAN OR NOT. 1 SD1 B. SEE ARCHITECTURAL AND LANDSCAPE DRAWINGS FOR ADDITIONAL MOUNTING DETAIL FOR SITE LUMINAIRES. C. ALL SITE POWER SHALL BE MINIMUM #10 WIRE IN 3/4 "C. SHEET NOTES CD 1. SEE 1/E6.0 FOR ATS FEEDER SIZES. SEE 1/E8.0 FOR ACCESSORY CIRCUITS AND CONTROLS. 2. 3. SD1 SD1 )--rDSD1 'S D 1 LCP -A -8,9 \SB2 \ ELECTRICAL SITE PLAN SCALE: 1.=20' 0 10' 20' 40' PROJECT SB2 4. 5. SEE 1/E6.0 FOR SECONDARY FEEDER SIZE. PROVIDE FIXTURE WITH BODINE ARCKEEPER AK175PRB REMOTE BALLAST. MOUNT BALLAST WITHIN 25' OF FIXTURE. REFER TO 1/E8.0 AND 2/E8.0 FOR ADDITIONAL INFORMATION ON GENERATOR SYSTEM. CONNECT TO NEW 20AMP, 2 POLE BREAKER IN EXISTING 120/208V POWER PANEL VIA 20AMP, 2 POLE RELAY. CONTROL RELAY FROM LCP —A. 6. CONNECT TO SERVING UTILITY. COORDINATE EXACT LOCATION AND UTILITY REQUIREMENTS. REVIEWED FOR �E CODE A 7 -NEC MAR -- 4 200B C'W Of Tukwila B . ILDIN DIVISION FLp8- 0'3 JAN, 112008 i- -anal Ic• Hi.; d ;:' -ir41- v t,t I.., to 408 t .91'.A C: } I 0 I 19 r?. 1111. !OW p on. 2 C 6.7 20.29L9 www. c r'fta rc hitectl .co m CONSULTANT C�LUM/�C 320 SW Wa43t11.,& j, si , ii1G Post 1fld, 0 1.82 207W2001A J. FERGUSON SEAL EXPIRES 01/28/2009 Revisions: 1 1.09.07 SITE RESUBMITTAL Sheet Title: ELECTRICAL SITE PLAN Date: II /q /07 Design: JKF Drawn: JKF Project No: 201W2001A Approved: Sheet No: E1.0 COPYRIGHT©2007 GLUMAC SPERRY DRIVE EXISTING LUMINAIRE APPROXIMATE LOCATION. FOR EXACT LOCATION. LCP—A-16,17 82 1 EXISTING LUMINAIRE APPROXIMATE LOCATION. REFER TO CIVIL PLAN FOR EXACT LOCATION. L.J ELECTRICAL SITE PLAN- PARCEL °B° SCALE: 1 =20' 0 10' 20' PROJECT NORTH GENERAL NOTES A. REFER TO ELECTRICAL DETAIL DRAWINGS FOR ADDITIONAL INFORMATION. ALL DETAILS APPLY FOR APPLICABLE SITUATIONS WHETHER REFERENCED ON THE PLAN OR NOT. B. SEE ARCHITECTURAL AND LANDSCAPE DRAWINGS FOR ADDITIONAL MOUNTING DETAIL FOR SITE LUMINAIRES. C. ALL SITE POWER SHALL BE MINIMUM #10 WIRE IN 3/4 "C. REVIEWED FOR CODE COMPLIANCE NFPA 70 NEC MAR - 200'B City Of Tukwila ILQ11... tRY ION EL08-- 0'13 JAN, 11 2008 le Hr.; Llmr nit Avenue € 408 f° €. 't;4fA 4 8 1 t) 11)6.il(I.1I)11 F'sincirici i`0 . 7 20 .29 i f www.craftarchitects.fiam z Ig < E x CONSULTANT CALU MAC 320 SW ..t'l 'li POLitf iij, Ct a xvu igtur, . t Nli lob T ry: 207W2001A C n4 4; J. FERGUSON SEAL EXPIRES 01/28/2009 Revisions: 1 1.09.07 SITE RESUBMITTAL Sheet Title: ELECTRICAL SITE PLAN - PARCEL 'B' Date: Design: Drawn: I I /q /01 JKF JKF Project No: 201■2001A Approved: Sheet No: E1.1 COPYRIGHT 02007 GLUMAC L: \_2007— Jobs \207W2001A.g2 \WF— E20.dwg 31 May 2007 — 4:43 pm JXF 27-2-7 1 )VERED I 1 UL1- 8,10,12,14 VJ ROOF HA's' ^,'ti SL1 B -54 TRANSFER 3 CAf1T MPF SORTER SI 1 -14,16 SL1 0 -50, RECEIVING MPF SORTER TRANSFER 2 TRUCK BAY SL1A -16 ;ft RAPK.11 TOMER RVICE TRANSFER 1 SL1A-18,20 SL1 B- 19,21,23 OUTGOING POD SL1 B -43,45 t;!R' 'DVIRiCONSOLE (I <I K; RACK, REFRIGERATOR I MICROWAVE GFI ,.iii�i' l , B iLC) �-�I- �1CITiT � ICROWAVE SL 1 B- 13,15,17 U,L1' S 1 B -24.__ .. UL1 -2,22 SL1 B 26 `: I REF KO 0 azi / III. 0 mil o i tea `pl1 Ar ...VI A II 11111111111r 4' 18 20 22 3H' L ® .:I) ,_G:'► 1,�� I- ►mI r� SL1B-42 i SL1B-5 SL1 -42 GUEST LOCKERS 1DETECTOR SL1A -14 C VAV 7 SL1 B- 25,27,29 PROCESSING CAt UL1 -33 MPF SORTER SL1A- 32,34,36 ilA`P f' MPF SORTER Si RA r'rn FUTURE TOSl- MAN TRAP SL1A-22,24 A COPY/ WORK AREA SUPPLIES UL1- 2x,30, SL1B 0 UNCN RO STAFF L 0 01M 11 'AV 11 11 111 S 1A-29,31,33 L1 B- 31,33,35 INNER VAULT ICON PALLET CON PALLET COIN PALLET' CON PAALL E I' 001; PALLET ' ail ORTER' Sl_1 A- 26,28,30" RA; PI1Ri' TOSHIBA. SORTER SL1 B -49,51 UL14'35,37,3 ELEC /TELCO SL1B-38 UL1-17,19 STORAGE 49 49 L. .. EXIT VESTIBULE 4 —r, 0 FARKIN 0 0 PARCEL LINE FIRST FLOOR PLAN - POWER/SIGNAL 111 SCALE: 1 /8 " =1' -0" 1•1 :I' it •.•U I �r1` I ,1 ..1 1 ; 1';C _..: 1.:1" 1 �•••uu..■ 4' 8' 16' PROJECT NORTH GENERAL NOTES A. PROVIDE #10 AWG, NEUTRALS TO ALL 15A AND 20A RECEPTACLES THAT SHARE A COMMON NEUTRAL, UNLESS OTHERWISE NOTED, 8, PROVIDE SINGLE GANG BOX AND 1"C. TO ACCESSIBLE CEILING AT EACH TELE /DATA ROUGH -IN LOCATION SHOWN UNLESS OTHERWISE NOTED, REFER TO DETAIL 3/E8,0 FOR ADDITIONAL INFORMATION. SHEET NOTES CD 1. CONNECTION TO WATERCOOLER, 2, PROVIDE FLEX WHIP POWER CONNECTION TO SPLINE OF ELECTRIFIED FURNITURE. 3. PROVIDE DOUBLE GANG J -BOX WITH (1) 1-1/2" CONDUIT TO ACCESSIBLE CEILING WITH PROTECTIVE BUSHINGS ON EACH END FOR TELE /DATA CONNECTION TO ELECTRIFIED FURNITURE. 4. PROVIDE CONNECTION TO TELE /POWER POLE WITH FLEX WHIP CONNECTION TO SPLINE ELECTRIFIED FURNITURE. TELE /POWER POLE PROVIDED BY FURNITURE VENDOR. 5, PROVIDE CONNECTION POWER SUPPLY PROVIDED BY SECURITY VENDOR, COORDINATE WITH SECURITY VENDOR PRIOR TO INSTALLATION. 6. PROVIDE 120V, 30A TWISTLOCK RECEPTACLE, 7, PROVIDE A DEDICATED NEUTRAL AND GROUND TO EACH RECEPTACLE IN SERVER ROOM. 8, PROVIDE LABEL ON COVERPLATE OF SWITCH THAT READS "SUPPLY FAN CONTROL ". 9. PROVIDE RECESSED FLOOR BOX WITH DEVICES SHOWN, PROVIDE 1"C, FROM BOTH POWER AND TELE /DATA SIDE OF BOX TO ACCESSIBLE CEILING. 10. PROVIDE CONNECTION TO OWNER FURNISHED DIRECTION LIGHTS. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS. 11. REFER TO 1/E8.0 AND 2/E8, 0 FOR CONNECTIONS TO GENERATOR REMOTE ANNUNCIATOR PANEL. 12. CONNECT FIRE ALARM ANNUNCIATOR TO FIRE ALARM CONTROL PANEL IN MAIN ELECTRICAL ROOM. REVIEWED COOS COMP,_ NCI + FPS, 0 MAR - 4 2000 City Of - f�ykail ELO8 0'13 0 0 JAN 1 1 2001 Terminal Sales Building 1932 First Avenue Suite 408 Seattle, WA 98101 2.06.720.7001 phone 206.720.2949 fax www.craftarchitects.corr: Cr C) Lu .1 0 co CD se ox CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 T. 503.227.5280 0. 503.274.7674 www.glurnac.com Job No.: 207W2001A Contact: J. FERGUSON 1. engineers for a sustainable future' 6 J 1EXPIRES 01/28/2009 Revisions: Sheet Title: Date: Design: Drawn: Project No: Q. Approved: FIRST FLOOR PLAN - POVR / SIGNAL 6/1/01 JKF JKF 2011200IA Sheet No: E2.0 COPYRIGHT © 2007 GLUMAC 'I! WP SL1 B- 10 WP n SL1 B -8 OV (R u) WP SL1 B -1,3 ROOF PLAN - POWER SCALE: 1 /8 " =1 ' -0" I I ..I • ••. 1 1- 1 1 1 1 1 1 I'.1 •.0 ■NN111111111 0 4' 8' 16' PROJECT NORTH GENERAL NOTES A. REFER TO DETAIL DRAWINGS FOR ADDITIONAL INFORMATION, ALL DETAILS APPLY FOR ALL APPLICABLE SITUATIONS WHETHER REFERENCED OR NOT, UON, 8, DO NOT ROUTE CONDUIT ON ROOF. RUN ALL HORIZONTAL CONDUIT BELOW ROOF. C. REFER TO MECHANICAL DRAWINGS FOR MOUNTING AND EQUIPMENT DETAILS. D. ALL EXTERIOR MOUNTED EQUIPMENT AND CONDUIT SHALL BE WEATHERPROOF RATED, MINIMUM NEMA 3R, E. ROUTE ALL CONDUITS UP THROUGH EQUIPMENT CURBS. COORDINATE LOCATION TO AVOID CONFLICTS AND ALLOW FOR CODE CLEARANCES AND MAINTENANCE ACCESS, F. INSTALL ALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS, THESE DRAWINGS ARE DIAGRAMMATIC. G. CIRCUIT SIZES ARE NOT SHOWN ON THE PLANS, CONTRACTOR SHALL USE CIRCUIT SIZES INDICATED IN NOTES OR RESPECTIVE SCHEDULES (PNL, MCC, ETC.) AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT SCHEDULES, REVIEWED FOR cO% COMPLIANCE NEC AR - 4 City Of Tukwila u!.LpIMS © V QN EL08-0y3 JAN ,11 2008 Terminal Sales Building 1 932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 206.720.2949 fax www.craftarchiitects.com Z CC Cr cc TUKWILA, WASHINGTON CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 T. 503.227.5280 F. 503.274.7674 www.glumac.corn Job No.: 207W2001A Contact: J. FERGUSON r i engineers for a sustainable future° J EXPIRES 01/28/2009 Revisions: Sheet Title: Date: Des 1(.0. Drawn: ign: CC 0. Approved: Project No: ROOF PLAN- FOYER 6 /I /01 JKF JKF 201112001A Sheet No: E2.2 COPYRIGHT C)2007 GLUMAC 11 GA ! 11 rwrrvnrrN.,` EXIT DA VESTIBULE EL1 -6,8 RECEIVING Ti ANSFER 2 mI,ff'w' MAMMA UWMIAIN TRUCK BAY (GUMMI TRANSFER RUINIVAVN -'V- -- - -- � � - - - - -, OWNW ai MOWN li MIS I■■■■ii...--wr / /i Ali • 3h 13 ! 3M 3h SL1 B -44,46 SL1A -37i LA2 NIPF SORTER. ///////////////////////////// /////// �DA UC REF $ I RECYC. mm 4•40' 44Eiria M N'S R.R. DA 'LUNCH f O RASH LCP -A-,1 !GA OCKERS MDF)ID M ' _PAL LE1 ON- ME" 41 I G?11N ! P;xLtil (COIN:_. PALLET 61 -1113A SORTER 0 s ,LLt;i,J, TYPICAl. SL1A-38 0 PARCFJ. M. 0 0 0 LANDSCAPING FIRST FLOOR PLAN - LIGHTING SCALE: 1/8"=1' -0" alum i ,i ; l .limmainummol PROJECT 0 4' 8' 16' NORTH GENERAL NOTES A. REFER TO DETAIL DRAWINGS FOR ADDITIONAL INFORMATION, ALL DETAILS APPLY FOR ALL APPLICABLE SITUATIONS WHETHER REFERENCED OR NOT, UON. B. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL LUMINAIRES. INFORM ENGINEER OF CONFLICTS. THE CIRCUITING SHOWN IS DIAGRAMMATIC. THE DRAFTING METHOD WHICH MOST SIMPLY CONVEYED THE CIRCUITING INTENT IS EMPLOYED. WHERE LUMINAIRES ARE SHOWN UNCONNECTED; CONNECT (IN A MANNER CONSISTENT WITH THE MATERIALS AND METHODS INDICATED IN THE SPECIFICATIONS AND DRAWINGS) FROM THE WIRING EXTENSION POINT SHOWN TO EACH LUMINAIRE USING: 1) MC CABLE IN HARD AND ACCESSIBLE CEILING AREAS -OR- 2) CONDUIT & WIRE ONLY IN EXPOSED AREAS. D, CONTRACTOR IS RESPONSIBLE FOR REVIEW OF ARCHITECTURAL DRAWINGS TO CONFIRM CEILING TYPES IN ALL ROOMS (ACCESSIBLE, EXPOSED, OR "HARD") AND TO USE THE APPROPRIATE WIRING METHOD FOR EACH TYPE, INSURE ALL J -BOXES ARE ACCESSIBLE AFTER ALL OTHER TRADE'S WORK IS COMPLETED, DO NOT LOCATE ANY J- BOXES ON "HARD" CEILINGS; ALL WIRING MUST BE ACCESSIBLE THROUGH LUMINAIRE ONLY IN "DAISEY- CHAIN" METHOD OR WITH DEDICATED HOMERUNS TO EACH LUMINAIRE. J -BOXES MAY BE LOCATED ABOVE OTHER TRADE'S ACCESS DOORS IF FEASIBLE AND DOES NOT INTERFERE WITH ACCESS. E. CIRCUIT SIZES ARE NOT SHOWN ON THE PLANS. CONTRACTOR SHALL USE CIRCUIT SIZES INDICATED IN NOTES OR RESPECTIVE SCHEDULES (PNL, MCC, ETC,) AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT SCHEDULES. F. DO NOT LOCATE JUNCTION BOXES ON WALLS, EXCEPT ONES REQUIRED TO MOUNT THE ITEM. THERE SHALL BE NO JUNCTION BOXES WITH BLANK COVERPLATES ON WALLS OR CEILINGS. G. WHERE MULTIPLE DEVICES (LIGHT SWITCHES, DIMMERS, ETC.) ARE LOCATED ADJACENT TO ONE ANOTHER, ALL DEVICES SHALL BE GANGED UNDER A SINGLE DEVICE COVER PLATE, H. CORRIDOR AND OPEN OFFICE AREA ARE CONTROLLED BY LIGHTING CONTROL PANEL TIME SWEEPS WITH LOCAL OVERRIDE SWITCHES, SHEET NOTES cf) CONNECT LUMINAIRE TO PANEL UL1, CIRCUIT 36. 2. CONNECT LUMINAIRE TO PANEL EL1, CIRCUIT 4. 3. PROVIDE FIXTURE WITH BODINE ARCKEEPER AK175PRB REMOTE BALLAST. MOUNT BALLAST WITHIN 25' OF FIXTURE. 4. PROVIDE CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR. 5, PROVIDE CEILING MOUNTED DUAL TECHNOLOGY, 360 DEGREE OCCUPANCY SENSOR. 6. PROVIDE WALL MOUNTED INFRARED OCCUPANCY SENSOR, 7, PROVIDE CEILING MOUNTED INFRARED OCCUPANCY SENSOR. 8. PROVIDE LOW VOLTAGE OVERRIDE WALL SWITCH, PROGRAM SWITCH TO CONTROL RELAY INDICATED, LOOH 3 JAN, 11 2008 ��ry:ivlL.oE PERMIT SET 05.31.07 Terminal Sales Building 1932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com z cc O Lu CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 T. 503.227.5280 F. 503.274.7674 www.glumac.com Job No.: 207W2001A Contact: J. FERGUSON r ■ engineers for a sustainable future- .11 Revisions: Sheet Title: FIRST FLOOR PLAN- LIGHTING Dote: Design: Drawn: Project No: Approved: 611101 JKF JKF 207012001A Sheet No: E3.0 COPYRIGHT ©2007 GLUMAC (200, 4K) 45 pm JXF : \_ 2007— Jobs \207W2001A.g2 \WF— t60.dwg S1 May 2001 COPPER FEEDER SCHEDULE FEEDER TAG (000 (1000.4) (1000.3) (800,4K) ( 800.4 ) ( 800.3 ) (400.4K) ( 400.4 ) ( 400.3 ) (350,4 ) ( 350.3 ) ( 300,4 ) ( 300.3 ) (250.4 ) (250.3) (225.4K) ( 225.4 ) ( 225.3 ) (200.4 ) ( 200.3 ) (175.4 ) (175.3) (150.4K) (150.4) ( 150,3 ) ( 125,4 ) (125.3) (1 10.4K) (110.4) (110.3) ( 100.4 ) 100.3-) ( XFR ) ( SCHD ) CONDUITS CONDUCTORS PER SET MET SETS RNC PHASE /NEUTRAL GROUND 3.50 3 4.00 " (3) 500 KCMIL, #2/0 (2) 400 KCMIL -N 3,00" 3 4.00" (4) 400 KCMIL #2/0 3.00" 3 4.00" (3) 400 KCMIL #2/0 3,00" 3 4.00" (3) 350 KCMIL, WO /0 (2) 300 KCMIL -N 3.00" 3 3,00" (4) 300 KCMIL #1 /o 2.50" 3 3.00" (3) 300 KCMIL #1/0 2.50" 2 2.50" (3) #4/0, #2 (2)#3/0 -N 2.00" 2 2.50" (4) #3/0 #2 2,00" 2 2.50" (3) 3/0 #2 3.50" 1 4.00" (4) 500 KCMIL #2 2.50" 1 4.00" (3) 500 KCMIL #2 3.00" 1 3.00" (4) 350 KCMIL #4 2.50" 1 3.00" (3) 350 KCMIL #4 2.50" 1 3,00" (4) 250 KCMIL #4 2.50" 1 3.00" (3) 250 KCMIL #4 3.00" 1 3.00" (3) 250 KCMIL, #4 (2) #4 /0 -N 2.50" 1 3.00" (4) #4/0 #4 2.00" 1 2.50" (3) #4/0 #4 2.50" 1 2.50" (3) #4/0,(2) #3 /O -N #6 2.00" 1 2.50" (4) #3/0 #6 2.00" 1 2.50" (3) #3/0 #6 2.00" 1 2.50" (4) #2/0 #6 1,50" 1 2.00" (3) #2/0 #6 2.00" 1 2.00" (3) #2/0,(2) #1 /0 -N #6 2,00" 1 2.00" (4) #1/0 #6 1.50" 1 2.00" (3) #1/0 #6 1.50" 1 1.50" (4) #1 #6 125" 1 1.50" (3) #1 #6 1.50" 1 2.00" (3) #2,(1) #4 /0 -N #6 1.25" 1 1.50" (4) #2 #6 1.25" 1 1.50" (3) #2 #6 125" 1 1,50" (4) #2 #8 1,25" 1 1.50" (3) #2 #8 NOTES 7 7 7 7 7 9 NOTES: 1, CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN /THWN INSULATION. 2, THIS SCHEDULE SHALL BE USED ON ALL FEEDERS SERVING LOADS WHERE THE CIRCUIT BREAKER SIZE MATCHES THE AMPACITY OF ITS FEEDER. USE THE "MOTOR CIRCUIT SCHEDULE" FOR LOADS, SUCH AS MOTORS, PUMPS, FANS, CHILLERS, ETC., WHERE THE CIRCUIT BREAKER SIZE IS LARGER THAN THE AMPACITY OF ITS FEEDER, 3, PROVIDE GROUND WIRE NOTED ABOVE IN ALL FEEDERS AND BRANCH CIRCUITS, WHERE MULTIPLE CONDUITS ARE INDICATED PROVIDE NOTED GROUND WIRE IN EACH CONDUIT. 4. NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT. 5, NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75 DEG.,C TERMINALS. 6. "MET "= EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC " = PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND, REFER TO SIZING ON DRAWINGS IF "RNC" CONDUITS ARE ROUTED ABOVEGROUND, CONDUIT SIZES NOTED ON SINGLE -LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. 7. OVERSIZED (173% MIN,) NEUTRAL FOR FEEDERS CONNECTED TO A K -4 OR HIGHER RATED TRANSFORMER, 8, REFER TO TRANSFORMER SCHEDULE FOR STANDARD PRIMARY AND SECONDARY FEEDER SIZES, 9, REFER TO MCC OR PANEL SCHEDULES FOR FEEDER SIZES TO EQUIPMENT NOTED WITH THIS TAG. LOAD SUMMARY CONNECT. LOAD SUMMARY LOAD (L) LIGHTING 33.9 (R) RECEPT. - 9 (M) MOTOR 3.1 (C) CONTINUOUS 120.1 (N) NON -CONT -®- 63.6 (K) KITCHEN--- 0 TOTAL - --- -> 230 WITH 25% SPARE - >287 DEMAND FACTOR 1.0 0.25 1.25 1.0 1.0 1.0 DEMAND KVA AMPS 42.4 9 3.1 150.1 63.6 0 117.7 25 8.6 417 176.7 0 269 746 336 932 _ CONN, LOAD SUMMARY PH, AMPS A 662.5 B 645.0 C 606.7 BRKR. AMPS 3CB EXTERNAL MAINTENANCE BYPASS FEEDER, TYPICAL BACKFEED PROTECTION 175A INPUT FUSES STATIC SW.TCH STATIC INVERTER ( 175.4) 175A ^a ■■■B 175A ®\ _ p 175A , OUTPUT OUTPUT FUSES CONTACTOR BATTERY CABINET #1 UPS MODULE FR3T FLOOR co J r• PNL UL1 22KAIC 13.1) ( 175.4 40 KVA/ 36 KW UPS SYSTEM 175.3 (77.4-7) UTILITY TRANSFORMER 300KVA PAD MOUNTED 208 120V,3O,4W,WYE 55/65 C. TEMP RISE 1 X44.0 L c) -(1000.4)- ;18.9) DIST.PNL SLD 1 22KAIC 400.4 PNL SL1B SECT. 1 22KAIC ( 400.4 ) KzLL) VATS ( 800.4 PNL SL1B SECT. 2 22KAIC PNL EL1 22KAIC (1 1 6) 800A 4 POLE 22 KAIC • t15 EL1 60A 4 POLE 22 KAIC GENERAL NOTES A, ALL CIRCUITS ARE 3 PHASE, UNLESS OTHERWISE NOTED. B. ITEMS SHOWN WITH SHADED SHORT - DASHED LINES ARE FUTURE. C, THE VALUE IN THE WIDE HEXAGON IS THE AVAILABLE INTERRUPTING SHORT- CIRCUIT CURRENT (AIC) AT THAT PIECE OF EQUIPMENT. SHEET NOTES GE) 1. PROVIDE SIZE AND QUANTITY OF CONDUITS REQUIRED BY PUGET SOUNDS ENERGY FOR PRIMARY CONDUCTORS. 2. INSTALL EQUIPMENT PER UTILITY REQUIREMENTS, 800.4 ( 60.4 ) REMOTE ANNUCIATOR PANEL IN BUNKER RM, 800AT 800AF 60AT 60AF CONTROLS 800AF800ATi ) 60AF60ATb ) BUSED SPACE 400AF BUSED SPACE 200AF J MAIN SWITCHBORAD MLS1 �?-°) 1000A, 208Y/120V, 3P, 4W & GND, 42KAIC ELECTRICAL - ONE -LINE DIAGRAM SCALE: NONE F.; FRST .. EG -1 450 KW/ 562 KVA 208V, 30, 4 WIRE DIESEL WITH 300 GALLON BASE TANK CODE. COMVISPAC,E. 0�0 1 \1W ELO8o'i3 .9 JAN 1 1 2008 Terminal Sales Building 1932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 200.720.2949 fax www.craftarchitects.com WELLS FARGO BANK 2 !lc' Lu CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 'C. 503.227.5280 E 503.274.7674 www.glumac.com Job No.: 207W2001A Contact: J. FERGUSON r '1 engineers fora sustainable future - L J EXPIRES 01/28/2009 Revisions: 0 Sheet Title: 0 Date: co Design: Drawn: cr Project No: a. Approved: ELECTRICAL - ONE LINE DIAGRAM 6/1/01 JKF JKF 201W200IA Sheet No: E6.0 COPYRIGHT C)2007 GLUMAC \_ 2007— Jobs \207W2001A.g2\WF— E80.dwg 31 May 2007 — 4:45 pm JXF SKID MOUNTED FUEL TANK Cg NORMAL CKT - — — Ink 20A, 120V, NORMAL CIRCUIT 20A, 120V, EMERGENCY CIRCUIT RADIATOR DIESEL ENGINE 4 #14 GENERATOR 41110118i 010101D• CONTROL PANEL ® — ®G MAXIMUM OF THREE 90 DEGREE BENDS TO REACH ACCESSIBLE CEILING AREA OR CABLE TRAY EXTEND DEDICATED CONDUIT TO NEAREST CABLE TRAY OR NEAREST ACCESSIBLE TILE CEILING SPACE FOR ALL OUTLETS IN AREAS WITH HARD CEILINGS AND AS SHOWN. MARK OUTLET BOX NUMBER ON CONDUIT, VISIBLE FROM BELOW, USE PERMANENT MARKER PEN, 3/4" HIGH LETTERS G WEATHERPROOF ENCLOSURE ®-- ® 20A, 120V, EMERGENCY CIRCUIT 2#10 20A, 120V, NORMAL CIRCUIT /-'GROUND ROD __Er; WELLS t- 1 G GENERATOR OUTPUT FEEDER TO ATS CONTROL WIRING TO ATS AND REMOTE EMERGENCY STOP SWITCH (EMS), 2 #12,1 "C TO ATS AND WIRES AS REQUIRED TO EMS. TO REMOTE ANNUNCIATOR PANEL 1 1/2"C,, WIRING PER MANUFACTURER'S INSTRUCTIONS NOTES: 1. LOAD TERMINATION JUNCTION BOX WITH CIRCUIT BREAKER. 2. GROUND LUG, 3, JUNCTION BOX FOR DUPLEX OUTLET. 4. BATTERY CHARGER WITH WIRING TO CONTROL PANEL AND REMOTE ANNUNCIATOR, 5. STARTING BATTERIES. 6. JACKET WATER HEATER (SET AT 110 DEGREES F. ). 7. JUNCTION BOX FOR CONTROL PANEL AND GENERATOR ANTI - CONDENSATION HEATERS. 8. BATTERY HEATER (50 - 60 DEGREES F. TEMPERATURE RANGE). 9. SKID FUEL TANK - TWO LEVEL SENSORS, ONE LEAK SENSOR WIRING 10. VERIFY CONDUIT STUB -UP LOCATIONS WITH SHOP DRAWINGS. COMBINE CIRCUITS 12, COMBINE CIRCUITS OUTDOOR DIESEL GENERATOR SCHEMATIC WIRING INSTALLATION SKID TANK NO LOAD BANK SCALE: NONE PROVIDE 1" EMT CONDUIT FOR SINGLE WORKSTATION OUTLET AND FOR SINGLE WALL MOUNTED OUTLET, USE 1.5" CONDUIT FOR OUTLETS SERVING A MAXIMUM OF 6 ELECTRIFIED FURNITURE WORKSTATIONS COMPRESSION TYPE EMT CONNECTOR LOCK NUT 16 4W0 4 IN A SINGLE 1" CONDUIT, IN A SINGLE 1" CONDUIT. 4" SQUARE DEEP JUNCTION BOX WITH SINGLE GANG PLASTER RING, U,O,N. USE CAST ALUMINUM SINGLE -GANG BOX WHERE BOX IS EXPOSED ON CONCRETE WALL. FINISHED FLOOR I' r, /41•PAKEN/ArAwW■01 Fr o SEE MOUNTING HEIGHT DETAIL 12 INSULATING BUSHING - STUB -OUT CONDUIT ABOVE ACCESSIBLE SUSPENDED CEILING OR AT LADDER TRAY LEVEL SUSPENDED OR HARD CEILING WHERE OCCURS PER ARCHITECTURAL DRAWINGS GYPSUM BOARD OR OTHER ROOM WALL SYSTEM FOR OUTLETS IN AREAS WITH HARD CEILINGS: MARK BACK OF BOX WITH UNIQUE BOX NUMBER, PER DRAWINGS. USE PERMANENT MARKER PEN, 3/4" HIGH LEIIERS, MATCH NUMBER TO END OF EXTENDED CONDUIT. UNLESS NOTED OTHERWISE COVERPLATE BY TELECOM CONTRACTOR. TELEPHONE DATA OUTLETS SCALE NONE NOTES: 1. GENERATOR CONTROL PANEL 4» 0 d 2. ALARM WIRING FROM SKID TANK'S TWO LEVEL AND ONE LEAK ALARM SENSORS TO GENERATOR CONTROL PANEL AND GENERATOR REMOTE ANNUNCIATOR PANEL (GRAP). 3, UNDERGROUND CONDUIT 4. ANNUNCIATION WIRING FROM GENERATOR TO GENERATOR REMOTE ANNUNCIATOR PANEL (CRAP); QUANTITY, TYPE AND SIZE PER MANUFACTURER'S INSTRUCTIONS 5, HARDWIRED DRY CONTACT WIRING FROM TWO SETS OF DRY CONTACTS ON THE GENERATOR CONTROL PANEL TO TWO DIGITAL INPUT POINTS IN BUILDING MANAGEMENT SYSTEM (BMS) FOR COMMON ALARM AND TROUBLE ANNUNCIATION (24 HOUR ANNUNCIATION) 6, HARDWIRED DRY CONTACT WIRING FROM TWO SETS OF DRY CONTACTS IN THE ATS FOR ANNUNCIATION OF NORMAL AND EMERGENCY POSITIONS AT THE GRAP, 7. GENERATOR REMOTE ANNUNCIATOR PANEL, LOCATE IN LOBBY NEAR ENTRY. 8. ABOVE GROUND CONDUIT 9, ALARM WIRING FROM BATTERY CHARGER TO CONTROL PANEL AND TO GRAP. 10, GENERATOR STOP /START CONTROL FROM ATS TO GENERATOR CONTROL PANEL AND REMOTE EMERGENCY STOP PUSHBUTTON WIRING FROM GENERATOR CONTROL PANEL TO PUSHBUTTON MOUNTED ADJACENT TO ATS. USE DEDICATED CONDUIT, 11. TO BMS SYSTEM INPUT POINTS BY DIV. 16 IG /-•-C4) P DIESEL GENERATOR WITHOUT LOAD BANK - ANNUNCIATION CONTROL WIRING SCHEMATIC SCALE: NONE ATS ID CO 4 (REQUIRED NFPA 1 10 LEVEL 1 INTERCONNECT WIRING.) 15'231 0 3 £LO9wOLL3 JAN 1 1 2006 VIP Terminal Sales Building 1932 First Avenue Suite 408 Seattle, AXJA 98101 206. 720.700 1 phone 206.720.2949 fax www.craftarchitects.cam WELLS FARGO BANK ix cc uj 0 co CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Porttand, OR 97204 T. 503.227.5280 F. 503.274.7674 www.glumao.com Job No.: 2Q7W2001 A Contact: J. FERGUSON r engineers for a sustainable future* d EXPIRES 01/28/2009 Revisions: Sheet Title: ELECTRICAL - DETAILS Date: Design: fx F— Drawn: Project No: 201112001A QW. Approved: 5/15/01 JXF Sheet No: E8.0 COPYRIGHT02007 GLUMAC 04/21/01 VF -E50 12 "MIN. 90" FFACPIE ,cAg‘ga 66" 2" BETWEEN BOXES TYP, 86" 6' -6" TO TOP CABINET QD LS ©(iQ vv• 1PQEQo COUNTER (SAD) QIPMQcp.vv NOTES 84" 44" 48" 18" NOTE: ALL DEVICES INDICATED TO BE INSTALLED AT DIFFERENT MOUNTING HEIGHTS AND LOCATED WITHIN ONE STUD SPACE FROM EACH OTHER SHALL ALIGN VERTICALLY, ON THE SAME SIDE OF THE STUD. WHERE WALL MOUNTED TELEPHONES OCCUR OVER LIGHT SWITCHES,VOLUME CONTROLS, ETC. OFFSET ONE STUD SPACE. ALIGN TOP OF BOXES FINISHED FLOOR A. HEIGHTS SHOWN ARE TYPICAL TO TOP OF BOX, UNLESS OTHERWISE NOTED. B. WHERE EVER DEVICES ARE INDICATED TO BE ABOVE DOORS, DEVICE SHALL BE CENTERED VERTICALLY BETWEEN TOP OF DOOR TRIM AND CEILING LINE AND CENTERED HORIZONTALLY ON DOOR OPENING, UNLESS OTHERWISE NOTED. C. MOUNTING HEIGHTS SHOWN ON ARCHITECTURAL ELEVATIONS SHALL GOVERN OVER THOSE SHOWN ABOVE. CONTRACTOR SHALL ALWAYS REFER TO ARCHITECTURAL DRAWINGS PRIOR TO INSTALLING J —BOXES AND BACKBOXES, INFORM ENGINEER AND ARCHITECT OF CONFLICTS, D. DO NOT MOUNT THERMOSTATS OR TEMPERATURE SENSORS ABOVE DIMMERS. INFORM ENGINEER OF CONFLICTS. ELECTRICAL TELECOM & SIGNAL SYS. DEVICE MOUNTING HEIGHTS & ALIGN. SCALE: NONE GENERAL NOTES A. PROVIDE EACH RECEPTACLE WITH A DEDICATED NEUTRAL AND GROUND. (2) 4 "C. SLEEVES 16'140-01 SHEET NOTES CD 1. PROVIDE (2) 120V, 20A, L5 -20R STRAIGHT BLADE TWIST —LOCK RECEPTACLES. 2. PROVIDE 24" GROUND BAR AND CONNECT TO MAIN SERVICE GROUND WITH #6 GROUND WIRE, 3. PROVIDE FIRE RESISTIVE PLYWOOD BACKBOARD FROM FLOOR TO CEILING. 4, PROVIDE EQUIPMENT WITH A #6 GROUND WIRE AND CONNECT TO GROUND BAR IN ROOM. 5. MOUNT (2) 120V, 20A, L5 -20R STRAIGHT BLADE TWIST —LOCK RECEPTACLES TO THE NETWORK RACK 6" FROM THE TOP. COORDINATE EXACT MOUNTING LOCATION WITH VENDOR PRIOR TO ROUGH —IN. UL1 -2,4,6 UL1 —7 ( SL1B-12 CD 5 UL1 -1,3,5 ENLARGED MDI /IDF ROOM SCALE: 1 /4 " =1' -0" I ' ;1 1 ° ■••■ ;1 1 1 1 1 1': 1 ■UR■ ' 1 1 1 •..•U• 0 2' 4' 8' #6 INSULATED GROUNDWIRE BOND TO FIXTURE, TYPICAL BOND TO POLE, TYPICAL #4 BARE COPPER GROUND WIRE; BOND TO POLE BASE SEE FIXTURE SCHEDULE PROVIDE 1" RADIUS CORNERS, SACK AND PATCH SURFACE TO UNIFORM FINISH. USE FORM LINER, SONOTUBE OR EQUAL GRADE (4) GALVANIZED J —BOLTS VERIFY SIZE WITH POLE MANUFACTURER CONCRETE 3000 PSI ri 1 arstr;= 11117.11 V4 sirartarmmuz isso ■ POLE (REFER TO LIGHT FIXTURE SCHEDULE FOR POLE DESCRIPTION) HAND HOLE BOND CONDUIT GROUND BUSHINGS & CIRCUIT GROUND CONDUCTOR TO POLE & FIXTURE STEEL BASE COVER LEVELING NUT AND WASHER GROUT SOLID UNDER BASE AFTER LEVELING / 2" l; ill -111 Ili- ill 1 l��_11 i, i l I I, :I l I I I_=;i ! f = ' I_� l 11.1=1 H, -i i #6 INSULATED GROUND WIRE EXOTHERMIC WELDED (CADWELD) CONNECTION, TYPICAL 3/4 "0x10' LONG COPPER —CLAD GROUND ROD AT EACH POLE FOOTING, TYPICAL VERIFY WITH STRUCTURAL ENGINEER DEPTH AND DIAMETER OF POLE BASE PRIOR TO FORMING MACHINE COMPACTED BACKFILL CONDUIT, SEE PLANS & SPECS (6) #6 VERTICAL REBAR, EQUALLY SPACED #6 HOOPS AT 6" OC I� LONG RADIUS, PVC COATED, SEE TABLE X RIGID STEEL CONDUIT ELBOWS SEE TABLE POLE HEIGHT BASE DIA. BASE DEPTH 0 -12 FT. 18" MIN, 5' -6" MIN. 13 -20 FT, 24" MIN. 6' -6" MIN, 21 -30 FT, 24" MIN, 7' —O" MIN, OUTDOOR NON- TRAFFIC AREA POLE BASE INSTALLATION SCALE: NONE 16521-01 BATTERY CABINET UPS MODULE PNL —UL1 LCP —A PNL —EL1 PNL—SL1 A DP—SLD 1 PNL —SL1 B ENLARGED ELECTRICAL ROOM SCALE: 1 /8 " =1 '— c 111 ' 11M••• 1 1 11.1 ^1 1 ME 0 4' 8' 16' REVIEWED b FOR CODE COMPLIANCE NFPA 70 City Of luimia LOB-O'f' JAN 11 2006 Produclion Dept SEAL OF ENGINEERING QUALITY Prole tMeneger Propel Engneer Terminal Sales Building 1932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com CO 2E F�- GIJ Lu Ne CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 T. 503.227.5280 F. 503.274.7674 www.glumac.com Job No.: 207W2001A Contact: J. FERGUSON r 7 engineers far a sustainable future' 6 r EXPIRES 01/28/2009 Revisions: O Sheet Title: ELECTRICAL - CD DETAILS Date: 6/1/07 ign: JKF DrawnDes: JKF ILI Project No: 2011'42001A Approved: a. Sheet No: E8.1 COPYRIGHT © 2007 GLUMAC L: \ _2007 -Jobs \207W2001A.g2 \WF-E70.dwg 31 Moy 2007 - 445 pm JXF LOCATION: MAIN ELECTRICAL ROOM Glurnec 2005 POLE NO. 1 3 LOAD SERVED PANEL SL1A 11 IV CKT SIZE 1LINE PANEL SLDI LOAD TYPE HP KVA SF 17.5 C.B. AMP POL 225 3 PH A C.B. LOAD AMP 400 POL 3 TYPE HP SF KVA 31.1 CKT SIZE 1LINE LOAD SERVED PANEL SL1B STANDBY POWER POLE NO. 2 5 SF SF 17.6 16.8 SF SF 28.1 4 25 7 9 11 13 PANEL UL1 11 i LINE SF 11.1 175 3 A 200 18.3 200.4 RTU-1 SF 10.6 18.3 SF 11.4 18.3 11 0 15 17 19 21 23 25 27 29 31 33 35 37 39 41 BUSED SPACE 1 A BUSED SPACE 6 8 10 12 14 BUSED SPACE 1 1 BUSED SPACE BUSED SPACE BUSED SPACE 1 1 BUSED SPACE 16 18 1 A BUSED SPACE 20 BUSED SPACE 1 1 BUSED SPACE 22 BUSED SPACE BUSED SPACE 1 BUSED SPACE 1 A BUSED SPACE 24 26 BUSED SPACE BUSED SPACE 1 1 BUSED SPACE BUSED SPACE 28 30 BUSED SPACE 1 A 1 BUSED SPACE 32 BUSED SPACE 1 1 BUSED SPACE 34 BUSED SPACE BUSED SPACE 1 1 BUSED SPACE 1 A BUSED SPACE 36 38 BUSED SPACE BUSED SPACE VOLTAGE: MOUNTING: MAIN: BUS RATING 1 BUSED SPACE 120Y/208V 30, 4W SURFACE 800A MLO 800A AIC RATING: SEE ONE LINE ADDITIONAL PANEL FEATURES: LOAD TYPE 1 CONN. DEMAND KVA FACTOR (L) LIGHTING -----------> (R) RECEPTACLES (M) MOTOR LOADS LARGEST MOTOR > (0) CONTINUOUS > (N) NON-CONTINUOUS > (K) KITCHEN EQUIP. > (.#) SPECIAL DEMAND > TOTAL WITH 9% SPARE -> 30.2 8.8 3.1 1.3 120.1 61.9 0 0 NEC 220-11 NEC 220-13 1.0 0.25 '1.25 1.0 1.0 1.0 1 DEMAND CONN LOAD KVA AMPS SUMMARY PH AMPS A 650.0 B 621.7 C 595.8 37.8 104.9 8.8 24.4 3.1 8.6 .3 .9 150.1 61.9 0 0 417 171.9 0 0 224 262 728 244 286 793 UPDATED: 5/3112007 212 pm \ _2007-Jobs \207W2001A.g2 \WF-E70.dwg 31 Moy 2007 - 445 pm JXF LOCATION: MAIN ELECTRICAL ROOM Glumac 2005 POLE NO. LOAD SERVED FED FROM: PANEL MLS1 SF = LOADS FROM SUBFED PANEL/MCC XFR = SIZE PER XFR SCHD BUSED SPACE CIRCUIT NOTES: 80% RATED PNL DMND FACTORS PROJECT: TOC ANNEX ISSUED FOR: PERMIT SET DATE ISSUED: 01-JUN-2007 40 42 CKT SIZE LOAD PANEL ELI C.B. TYPE HP KVA AMP C.B. LOAD POL PH AMP POL TYPE HP KVA CKT SIZE EMERGENCY POWER LOAD SERVED POLE NO. 1 GENERATOR OUTLET 20.1 R .2 20 1 A 20 1 L .5 20.1 GENERATOR BATTERY CHARGER 7 FIRE ALARM CONTROL PANEL SPARE BREAKER 20.1 N 1.2 20 B 20 1.6 20.1 EXIT SIGNS 20.1 .5 20 1 20 .8 20.2N EGRESS LIGHTING EXTERIOR EGRESS LIGHTING 20 1 A 9 11 SPARE BREAKER SPARE BREAKER 20 20 SPARE BREAKER 20 1 C 20 1 SPARE BREAKER 2 4 6 8 10 12 13 15 17 SPARE BREAKER SPARE BREAKER SPARE BREAKER VOLTAGE: MOUNTING: MAIN: BUS RATING 20 1 20 SPARE BREAKER 20 1 B 20 1 SPARE BREAKER 120Y/208V 30, 4W SURFACE 100A MLO 100A AIC RATING: SEE ONE LINE ADDITIONAL PANEL FEATURES: UPDATED: 513012007 457 pm \ _2007-Jobs \207W2001A,g2 \WF-E70.dwg 31 Moy 2007 - 445 pm JXF LOCATION: MAIN ELECTRICAL ROOM Glumac 2005 POLE NO. 1 3 5 1 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 LOAD SERVED MDF / IDF RECEPTACLES 20 1 C 20 1 CONN. DEMAND DEMAND LOAD TYPE KVA FACTOR KVA AMPS CONN LOAD SUMMARY SPARE BREAKER (L) LIGHTING -------_-_> (R) RECEPTACLES -----> (M) MOTOR LOADS LARGEST MOTOR > (C) CONTINUOUS > (N) NON-CONTINUOUS > (K) KITCHEN EQUIP. > (.#) SPECIAL DEMAND > 3.7 .2 0 0 0 1.7 0 0 NEC 220-11 NEC 220-13 1.0 0.25 1.25 1.0 1.0 1.0 4.6 .2 0 0 0 1.7 0 0 12.8 .6 0 0 0 4.7 0 0 TOTAL 6 7 18 WITH 25% SPARE 23 PH AMPS A 12.5 B 23.3 10.8 80% RATED PNL DMND FACTORS FED FROM: PANEL MLS1 SF = LOADS FROM SUBFED PANEUMCC XFR = SIZE PER XFR SCHD CKT SIZE 20.1 psgsgs.spessassompar PANEL UL1 LOAD TYPE HP KVA .5 C.B. AMP POL 20 1 PH A C.B. CIRCUIT NOTES: 14 16 18 PROJECT: TOC ANNEX ISSUED FOR: PERMIT SET DATE ISSUED: 01-JUN-2007 LOAD AMP 20 POL 1 TYPE, HP KVA .5 CKT SIZE 20.1 MDF / IDF RECEPTACLES 20.1 .5 20 1 20 1 .5 20.1 LOAD SERVED MDF / IDF RECEPTACLES MDF 1 IDF RECEPTACLES COMPUTER OUTLETS 20.1 .5 20 1 20 .5 20.1 MDF / IDF RECEPTACLES MDF 1 IDF RECEPTACLES UPS POWER POLE NO. MDF / IDF RECEPTACLES 2 4 6 : \ _2007-Jobs \ 2071'2001AV \WF-70.dwg 31 Moy 2007 - 4:45 pm JXF LOCATION: MAIN ELECTRICAL ROOM Glomac 2005 POLE NO. 1 LOAD SERVED GENERATOR JACKET HEATER 3 GENERATOR CONTROL PANEL 5 GENERATOR BATTERY HEATER 7 EXTERIOR LIGHTING 9 11 11 11 EXTERIOR LIGHTING CKT SIZE 20.1 20.1 20.1 20.2N TYPE N N LOAD HP PANEL SLIA KVA .5 .5 C.B. AMP POL 20 20 N .5 20 L 1.5 20 L 1.5 30.2N 20.1 C .5 20 A 20 1 1.6 20.1 SERVER ROOM 8 20.1 N .8 20 1 20 1 1.6 20.1 SERVER ROOM 10 COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 20 1 1.6 20.1 SERVER ROOM 12 20.1 N .8 20 1 A 20 1 1.6 20.1 COMPUTER OUTLETS 20.1 .8 20 1 20 1 .8 20.1 SERVER ROOM COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 1 20 .8 20.1 COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 1 A 20 .8 20.1 20.1 N .8 20 1 20 1 .8 20.1 COMPUTER OUTLETS 20.1 N .8 20 1 20 .8 20.1 COMPUTER OUTLETS COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 1 A 20 1 .8 20.1 COMPUTER OUTLETS COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 1 20 1 .8 20.1 14 16 18 20 COMPUTER OUTLETS 22 COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 1 20 1 .8 20.1 COMPUTER OUTLETS 20.1 N .8 20 1 A 20 .8 20.1 COMPUTER OUTLETS 20.1 .8 20 1 20 .8 20.1 COMPUTER OUTLETS 24 26 COMPUTER OUTLETS COMPUTER OUTLETS 28 30 32 34 13 15 EXTERIOR LIGHTING 17 19 KITCHEN APPLIANCE RECEPTACLES 21 LUNCH ROOM MICROWAVE 23 KITCHEN APPLIANCE RECEPTACLES 25 DISPOSAL 27 REFRIGERATOR L 1.8 25 1 1 PH A B 1 L 1.8 30.2N L 1.5 30 29 VENDING MACHINE 31 VENDING MACHINE 33 LUNCH ROOM RECEPTACLES 35 LIGHTING 37 LIGHTING 39 LIGHTING 41 LIGHTING VOLTAGE: MOUNTING: MAIN: BUS RATING 120Y/208V 30, 4W SURFACE 225A MLO 225A AIC RATING: SEE ONE LINE ADDITIONAL PANEL FEATURES: UPDATED: 5/300007 143 pm \ _2007-Jobs \ 2071112001A.g2 \WFE70.dwg 31 May 2007 - 4:45 pm JXF LOCATION: MAIN ELECTRICAL ROOM Glume9 2095 POLE NO. 1 3 5 LOAD SERVED CU-2 VI 20.1 20.1 20.1 20.1 20.1 20.1 20.1 20.1 20.1 20.1 20.1 20.1 L 1.5 2 A 2 A R .4 20 C.B. AMP POL TYPE 2 B N 1.2 20 R .4 20 M 1.2 20 1 A 1.8 20 1.8 20 1 B 30 2 L L 1 1.8 20 R .5 20 1 A 40 2 L L 1 B L 1.4 20 L 1.4 20 1 40 2 L LOAD HP KVA 1.5 CKT SIZE 30.2N 1.5 1.5 40.2N STANDBY POWER LOAD SERVED L 1 A L 1.7 20 1 LOAD TYPE (L) LIGHTING (R) RECEPTACLES ----- --> (M) MOTOR LOADS LARGEST MOTOR > (C) CONTINUOUS (N) NON-CONTINUOUS > (K) KITCHEN EQUIP. > (.#) SPECIAL DEMAND > 20 1 B 1 1 A 1 B 1 1.8 20 1 20 1 R 1.1 • 20.1 EXTERIOR LIGHTING POLE NO. 2 1.3 20.1 20 1 R 20 1 N .5 20.1 11 EXTERIOR LIGHTING 20 1 N 20 1 1.3 20.1 .9 20.1 1.5 20.1 1 20.1 1 20.1 EXTERIOR LIGHTING 11 LOCKER & RESTROOM RECEPTACLES 20 1 N 20 1 N 20 1 N 20 1 N 20 1 L 1 20.1 1 20.1 20 1 L 20 1 R CONN. DEMAND DEMAND KVA FACTOR KVA AMPS 1 20.1 RECEIVING RECEPTACLES WATERCOOLER 1 20.1 1.5 20.1 1.4 20.1 CONFERENCE ROOM RECEPTACLES WORK AREA RECEPTACLES 1.1 20.1 27.6 7 1.2 1.2 5.9 10.2 0 0 TOTAL -> 52 WITH 25% SPARE -> 65 FED FROM: PANEL SLDI NEC 220-11 NEC 220-13 1.0 0.25 1.25 1.0 1.0 1.0 34.5 7 1.2 .3 7.4 10.2 0 0 95.8 19.4 3.3 .8 20.5 28.3 0 0 CONN LOAD SUMMARY PH AMPS A 145.8 B 146.7 C 140.0 61 168 76 210 SF = LOADS FROM SUBFED PANEL/MCC XFR = SIZE PER XFR SCHD SF-1 CKT SIZE TYPE 20.2N N 20.1 M LOAD HP 80% RATED PNL DMND FACTORS 6 8 10 COPIER SORTER SORTER SORTER SORTER 12 14 16 18 20 22 24 26 28 SORTER SORTER LIGHTING CIRCUIT NOTES: PROJECT: TOC ANNEX ISSUED FOR: PERMIT SET DATE ISSUED: 01-JUN-2007 PANEL SLIB (SECTION 1) .3 KVA 1.8 1.8 .7 C.B AMP 20 20 POL 2 1 C.B. LOAD POL TYPE HP KVA 2 C " 3 3 1 N .5 CKT S IZE 40.2N LOAD SERVED EWH-1 30 32 34 36 38 40 42 STANDBY POWER POLE NO. 2 4 20.1 LIGHTING CONTROL PANEL 7 EF-1 20.3M M 9 .8 .4 20 3 A 25 1 2 30.1 CU-1 .4 20 1 R .5 20.1 ROOFTOP RECEPTACLES 11 13 15 17 VAV-1,2,3 11 40.4 C .4 3.3 3.3 3.3 35 3 A 20 20 20 C 2 C 1 R .5 1.5 1.5 .4 20.1 CRAC-1 20.2N EWH-1 6 8 10 12 14 11 l 16 20.1 19 VAV-4,5 21 VS 40.4 C 3.3 35 3 A 20 1 N 1.2 20.1 3.3 20 1 N 1.2 20.1 BUNKER ROOM RECEPTACLES BUNKER ROOM MICROWAVE BUNKER ROOM REFRIGERATOR 18 20 22 23 3.3 C 20 1 N 1 20.1 WORKSTATIONS 24 25 27 VAV-6 30.4 2.5 30 3 A 20 1 20.1 WORKSTATIONS 26 2.5 20 1 N 1 20.1 WORKSTATIONS 28 29 31 2.5 C 20 1 N 1 20.1 33 VAV-7,8,9 0 11 40.4 3.8 40 3 A 20 1 N 20.1 WORKSTATIONS WORKSTATIONS 30 32 3.8 20 1 N 1 35 37 39 11 0 VAV-10,11 11 30.4 41 Of VOLTAGE: MOUNTING: MAIN: BUS RATING 120Y/208V 30, 4W SURFACE 400A MLO 400A AIC RATING: SEE ONE LINE ADDITIONAL PANEL FEATURES: FEED-THRU LUGS 91 Tcts1/6 WM A g2 F-E70.dwg 31 Moy 2007 - 445 pm JXF LOCATION: MAIN ELECTRICAL ROOM Ok4meto 2005 3.8 2.3 2.3 2.3 25 LOAD TYPE CONN. KVA 20 1 3 20 1 B 20 1 N C 20 1 N DEMAND DEMAND FACTOR KVA AMPS .5 .5 CONN LOAD SUMMARY (L) LIGHTING (R) RECEPTACLES ----- --> (M) MOTOR LOADS LARGEST MOTOR > (C) CONTINUOUS ------ > (N) NON-CONTINUOUS > (K) KITCHEN EQUIP. > (.#) SPECIAL DEMAND > 2.1 1.8 1.9 1.3 59.3 19.1 0 0 NEC 220-11 NEC 220-13 1.0 0.25 1.25 1.0 1.0 1.0 2.6 1.8 1.9 .3 74.1 19.1 0 0 7.3 5 5.3 .9 205.9 53.1 0 0 TOTAL -> 84 WITH 25% SPARE -> 105 FED FROM: PANEL SLD1 100 125 277 347 PH A AMPS 234.2 217.5 176.7 20.1 WORKSTATIONS 34 20.1 WORKSTATIONS 36 20.1 WORKSTATIONS 38 20.1 WORKSTATIONS 40 20.1 SECURITY POWER SUPPLY 42 CIRCUIT NOTES: 80% RATED PNL DMND FACTORS PROJECT: TOC ANNEX ISSUED FOR: PERMIT SET DATE ISSUED: 01-JUN-2007 SF = LOADS FROM SUBFED PANEL/MCC XFR = SIZE PER XFR SCHD POLE NO. LOAD SERVED 43 45 DIRECTION LIGHTS PANEL SL1 p (SECTION 2) CKT LOAD C.B. C.B. LOAD CKT SIZE TYPE HP KVA AMP POL PH AMP POL TYPE HP KVA SIZE 20.1 .5 20 1 A 1 20 2 .3 STANDBY POWER 20.2N LOAD SERVED TRUCK BAY LIGHTING POLE NO. DIRECTION LIGHTS 20.1 .5 20 1 .3 44 46 47 DIRECTION LIGHTS 49 STORAGE RECEPTACLES 51 SORTER 53 EUH-1 20.1 20.1 20.1 20.2N 55 57 .5 .7 1.3 1.3 20 20 20 20 1 1 1 2 • 20 1 A 20 2 C 20 1 .2 .2 .2 1.8 20.1 20.2N ELECTRICAL ROOM RECEPTACLE 48 CRAC-2 50 11 0 52 20.1 VENDING MACHINE 54 A 20 9 SPARE BREAKER 56 SPARE BREAKER 20 1 B 20 1 SPARE BREAKER 58 59 61 SPARE BREAKER BUSED SPACE 20 1 C 20 1 SPARE BREAKER 20 1 A 20 1 BUSED SPACE 63 65 67 69 BUSED SPACE 20 1 B 20 1 BUSED SPACE 60 BUSED SPACE 20 C 20 1 BUSED SPACE BUSED SPACE BUSED SPACE 71 73 BUSED SPACE BUSED SPACE 75 COMPUTER OUTLETS COMPUTER OUTLETS 20.1 N .8 20 1 20 1 .5 20.1 UPS LIGHTING 36 20.1 N .8 20 A 20 SPARE BREAKER 38 39 COMPUTER OUTLETS 41 SPARE BREAKER VOLTAGE: 120Y/208V 30, 4W MOUNTING: SURFACE MAIN: 175A MLO BUS RATING 225A AIC RATING: SEE ONE LINE ADDITIONAL PANEL FEATURES: UPDATED: 5131/2007 221 pm 20.1 .8 20 20 1 LOAD TYPE 20 1 C 20 1 CONN. DEMAND DEMAND KVA FACTOR KVA AMPS CONN LOAD SUMMARY (L) LIGHTING ------------> (R) RECEPTACLES (M) MOTOR LOADS LARGEST MOTOR > (0) CONTINUOUS > (N) NON-CONTINUOUS > (K) KITCHEN EQUIP. (.#) SPECIAL DEMAND > TOTAL WITH 25% SPARE -> .5 0 0 0 9.9 20.8 0 0 NEC 220-11 NEC 220-13 1.0 0.25 1.25 1.0 1.0 1.0 .6 0 0 0 12.4 20.8 0 0 1.7 0 0 0 34.4 57.8 0 0 31 34 94 39 42 117 FED FROM: PANEL SLD1 SF = LOADS FROM SUBFED PANEL/MCC XFR = SIZE PER XFR SCHD PH A AMPS 92.5 88.3 79.2 80% RATED PNL DMND FACTORS SPARE BREAKER SPARE BREAKER CIRCUIT NOTES: PROJECT: TOC ANNEX ISSUED FOR: PERMIT SET _ DATE ISSUED: 01-JUN-2007 40 42 77 BUSED SPACE BUSED SPACE 79 81 BUSED SPACE BUSED SPACE 83 BUSED SPACE VOLTAGE: 120Y/208V 30,4W MOUNTING: SURFACE MAIN: 400A MLO BUS RATING 400A AIC RATING: SEE ONE LINE LOA D TYP 20 20 20 20 20 20 20 20 20 CONN. KVA 1 1 1 1 1 A 20 B 20 C 20 A 20 B 20 1 C 20 1 1 A 20 1 1 B 20 1 1 C 20 1 DEMAND DEMA FACTOR KVA ND AMPS BUSED SPACE BUSED SPACE BUSED SPACE BUSED SPACE BUSED SPACE BUSED SPACE BUSED SPACE BUSED SPACE BUSED SPACE 62 64 66 68 70 72 74 76 78 80 82 84 CONN SUM LOAD MARY ADDITIONAL PANEL FEATURES: UPDATED:. 513112007 2:24 pm (L) LIGHTING ----------> 2.1 (R) RECEPTACLES ----- ---> 1.8 (M) MOTOR LOADS > 1.9 LARGEST MOTOR > 1.3 (C) CONTINUOUS ------ > 59.3 (N) NON-CONTINUOUS > 19.1 (K) KITCHEN EQUIP. > 0 (.#) SPECIAL DEMAND > 0 NEC 220-11 NEC 220-13 1.0 0.25 1.25 1.0 1.0 1.0 2.6 1.8 1.9 .3 74.1 19.1 0 0 7.3 5 5.3 .9 205.9 53.1 0 0 TOTAL -> 84 100 277 WITH 25% SPARE -> 105 125 347 FED FROM: PANEL SL1B (SECTION 1) SF = LOADS FROM SUBFED PANEL/MCC XFR = SIZE PER XFR SCHD PH A AMPS 25.0 16.7 31.7 80% RATED PNL DMND FACTORS CIRCUIT NOTES: PROJECT: TOC ANNEX ISSUED FOR: PERMIT SET DATE ISSUED: 01-JUN-2007 SIDIOISMSSSIIMM.S.S. CIRCUIT TAG ( 60.2N) ( 60.) ( 601 ) ( 50.2N) ( 50.2) ( 50,1 ) ( 40.2N ) ( 40.2 ) ( 40.1) ( 30,2N ) ( 30.2) ( 30,1 ) ( 20.2N) ( 20,2) ( 20,1 ) FEEDER TAG (200,3M) (1 75.3M) (150.3M) (125.3M) (110.3M) (100,3M) ( 90.3M) ( 80.3M ) (60.3m) (5o.3m) (40.3m) (30.3m) (20.3m) MOTOR CIRCUIT SCHEDULE CONDUITS 0 CONDUCTORS PHASE/NEUTRAL PER SET GROUND 0 MET SETS RNC 2.00" 1 2.50" (3) #3/0 #3 2,00" 1 2.50" (3) #2/0 #3 1.50" 1 2.00" (3) #1/0 #4 1.50" 1 2.00" (3) #1 #4 1.25" 1 2.00" (3) #2 #6 1,25" 1 2.00" (3) #2 #6 1 .25" 1 1,50" (3) #4 #6 1.25" 1 1,50" (3) #4 #6 1.25" 1 1,50" (3) #4 #6 1.00" 1 1.50" (3) #6 #8 0,75" 1 1.50" (3) #6 #6 0.75" 1 1.00" (3) #8 #8 0.75" 1 1,00" (3) #10 #10 0,50" 1 1.00" (3) #12 #12 REMARKS GENERAL NOTES A, CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN/THWN INSULATION, B. THIS MOTOR BRANCH CIRCUIT SCHEDULE SHALL BE USED FOR ALL CIRCUITS WHERE THE CIRCUIT BREAKER SIZE PROTECTING THE LOAD IS LARGER THAN THE AMPACITY OF THE CIRCUIT CONDUCTORS, EXAMPLES ARE: MOTORS, CHILLERS, ELEVATORS, FANS, PUMPS, ETC. C. PROVIDE NOTED SIZE GROUND CONDUCTOR IN EACH CONDUIT OF CIRCUITS CONSISTING OF MULTIPLE SETS OF PARALLEL CONDUCTORS, D. NOT ALL CIRCUITS ARE NECESSARILY USED ON THIS PROJECT, E, NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75C TERMINATIONS, F. ON CIRCUITS SHOWN WITH A ".6M" SUFFIX, PROVIDE SIX PHASE CONDUCTORS AND ONE GROUND WIRE IN CODE SIZED CONDUIT. INCLUDE 80% DERATING FACTOR ON PHASE CONDUCTOR SIZE. SCHEDULE REMARKS 0 "MET= EMT, GRC (RIGID), RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC"= PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND, REFER TO SIZING ON DRAWINGS IF "RNC" CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES NOTED ON SINGLE-LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. 0 PROVIDE GROUND WIRE NOTED IN ALL MOTOR BRANCH CIRCUTS. BRANCH CIRCUIT SCHEDULE CONDUITS CONDUCTORS PER SET MET SETS RNC PHASELNEUTRAL GROUND 0,75" 1 1.00" (2) #6, (1) #6N #10 0,75" 1 1.00» (2) #6 #10 0.75" • 1,00" (1) #6, (1) #6N #10 0.75" 1 1.00" (2) #6, (1) #6N #10 0.75" 1 1,00" (2) #6 #10 0.75" 1 1,00" (1) #6, (1) #6N #10 0.75" 1 1.00" (2) #8, (1) #8N #10 0,75" 1 1.00" (2) #8 #10 0.75" 1 1.00" (1) #8, (1) #8N #10 0,75" 1 1.00» (2) #10, (1) #10N #10 0.75" 1 1.00" (2) #10 #10 0.75" 1 1,00" (1) #10, (1) #10N #10 0.50" • 1.00" (2) #12, (1) #12N #12 0.50" 1 1.00" (2) #12 #12 0.50" 1 1,00" (1) #12, (1) #12N #12 WIRING CONFIG. NOTES 10,2WN 102W 101WN 10,2WN 10,2W 10,1W,N 10,2W,N 102W 101W,N 10,2WN 10,2W 101WN 102WN 10,2W 10,1WN 78 7,8 7,8 NOTES: 1. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN/THWN INSULATION. 2. THIS SCHEDULE SHALL BE USED ON ALL BRANCH CIRCUITS SERVING LOADS WHERE THE CIRCUIT BREAKER SIZE MATCHES THE AMPACITY OF ITS FEEDER. USE THE "MOTOR CIRCUIT SCHEDULE FOR LOADS, SUCH AS MOTORS, PUMPS, FANS, CHILLERS, ETC., WHERE THE CIRCUIT BREAKER SIZE IS LARGER THAN THE AMPACITY OF ITS FEEDER, 3. PROVIDE GROUND WIRE NOTED ABOVE IN ALL BRANCH CIRCUITS. 4. NOT ALL BRANCH CIRCUITS SHOWN ABOVE ARE NECESSARILY USED ON THIS PROJECT, 5. "MET"= EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS, "RNC"= PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND. REFER TO SIZING ON DRAWINGS IF "RNC" CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES NOTED ON SINGLE-LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER, 6, THIS SCHEDULE APPLIES TO STANDARD LENGTH CIRCUITS ONLY, CONTRACTOR TO UPSIZE WIRING AS REQUIRED TO MEET MINIMUM VOLTAGE DROP REQUIREMENTS INDICATED IN SPECIFICATIONS. GROUND CONDUCTOR WILL ALSO NEED TO BE INCREASED PROPORTIONATELY AS REQUIRED BY NEC, 7, THESE BRANCH CIRCUITS TAGS ARE TYPICALLY NOT SHOWN ON PLANS FOR CLARITY REASONS. CONTRACTOR SHALL USE THIS INFORMATION AS IT APPLIES FOR ALL CONDUITS CONTAINING ONE OR MORE 20A/1P CIRCUITS, 8, CONTRACTOR MAY COMBINE 20A 1 AND 2-POLE CIRCUITS, UP TO A MAXIMUM OF 4 PHASE CONDUCTORS, IN ONE CONDUIT, ALL 3-PHASE AND CIRCUITS LARGER THAN 20A SHALL BE IN DEDICATED CONDUITS, UON, WHERE NEUTRALS FOR 20A CIRCUITS ARE SHARED, THE MINIMUM NEUTRAL WIRE SIZE SHALL BE #10 AWG., ONE PER "ROUNDHOUSE." 9. ALL HOMERUNS SHALL USE 0.75" CONDUIT SIZE MINIMUM, EL08-093 REVIEWED FOR ODE COMPLIANCE NFPA 70 - NEC MAR - city orrukwita puiaNumsjom JAN 1 1 2008 Terminal Sales Building 932 First Avenue Suite 408 Seattle, WA 98101 206.720.7001 phone 206.720.2949 fax www.craftarchitects.com z LL co mimermemommil CONSULTANT GLUMAC 320 SW Washington St., Suite 200 Portland, OR 97204 T. 503.227.5280 F. 503.274.7674 www.glumac.com Job No.: 207W2001A Contact: J. FERGUSON engineers for a sustainable future SEAL EXPIRES 01/28/2009 Revisions: 0 Sheet Title: - Date: (j) Design: Drawn: cr Project No: Approved: ELECTRICAL PANEL SCHEDULES 5/15/01 JXF 201112001A Sheet No: E7 .0 limasmannamemerdmiss COPYRIGHT 02007 GLUMAC 04/21/01 1^1F-E01