HomeMy WebLinkAboutPermit EL08-0056 - WESTFIELD SOUTHCENTER MALL - SARKU JAPANSARKU JAPAN
2600 SOUTHCENTER MALL
FC -3
ELO8-056
Parcel No.:
Address:
Suite No:
CitAof Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ELECTRICAL PERMIT
6364200010
2600 SOUTHCENTER MALL TUKW
Permit Number:
Issue Date:
Permit Expires On:
EL08 -056
03/25/2008
09/21/2008
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
SARKU JAPAN
2600 SOUTHCENTER MALL FC -3 , TUKWILA WA
WEA SOUTHCENTER LLC
11601 WILSHIRE BLVD , LOS ANGELES CA
TIM PETTIFER
Address: 7650 BIRCHMOUNT RD , MARKHAM, ONTARIO, CANADA
Contractor:
Name: D F ELECTRIC INC
Address: PO BOX 7205 , TACOMA WA
Contractor License No: DFELEI *010D9
Phone:
Phone: 416- 891 -3327
Phone: 253 572 -3704
Expiration Date: 03/31/2009
DESCRIPTION OF WORK:
ELECTRICAL SYSTEMS FOR LIGHTING AND RECEPTACLES
Value of Electrical: $30,000.00
Fees Collected: $717.50
Type of Fire Protection: National Electrical Code Edition: 2005
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Date: 074
I hereby certify that I have read and ex ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie • h, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfo . ance of work. I am authorized to sign and obtain this electrical permit.
Signature:
Print Name:
4,0//r„, y
Date: 3r2 s-��
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -056 Printed: 03 -25 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 6364200010 Permit Number: EL08 -056
Address: 2600 SOUTHCENTER MALL TURIN Status: ISSUED
Suite No: Applied Date: 01/16/2008
Tenant: SARKU JAPAN Issue Date: 03/25/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Signature:
Print Name:
•, dZw �e�,7'�e�j
Date: 3 ' Z J — e�
doc: Cond -Elec
EL08 -056 Printed: 03 -25 -2008
CITY OF TUKWIL•
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
•
Electrical Permit No. - LC os
rosoE
Project No.
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not he accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
�� *� �pp I. King Co a Assessor's Tax No.: (L ? 1 1-( )-U " w 1 G�
Site Address: (..0-S Cel er- Tkw9 Tuk►ka, �(X 9s1iS$" 2ii S5 Suite Number: re.- S Floor: 2
Tenant Name: cRik InOviiv.e.riier Food Itic. DF3P SOrktA £n New Tenant: fSI Yes ❑ ..No
Property Owners Name: W F Pr cD q c.eriter . L LC
t- r �
Mailing Address: 1 [ (o01 1 1 s �, (',----e_, Bl.vo1 1 I'A, FJr)ar A c g, , ,,Je ) Oa 9br) 25
City State Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: j r ►'�'{ ']�,/ 1)
Mailing Address: }%650 B 'rdl✓vtdwtf Rd
E -Mail Address: +p 4 t f d 30-' kt poi- . c M
Day Telephone: H 1 (,,D - 8°11
via ek.t-
City
t `lt>f`; o Co4oe4 l 3 R
State Zip
Fax Number: e(05, 7/4 -042 -1
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number: Expiration Date:
City
Day Telephone:
Fax Number:
State
Zip
Valuation of Project (contractor's bid price): $ Spi 000
Scope of Work (please provide detailed information): Ca I S j Wt5 . �l �( kb' �t-�j / 5 t.iit by
ve IQ.� `T'a L�S �J U V ( Q
Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No
Type of Use: Re_ Sfstlit.� r c $
Type of work:
New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement
❑ Low Voltage ❑ Generator [a. Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
❑ Puget Sound Energy
❑ Seattle City Light
H tApphcahor l orms- Applications On Line \4-2007 - Electrical Permit Application doe
hh
Page 1 of 2
1
'4
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ Ncw single family dwellings $140.00
(including an attached garage)
❑ Garages. pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm. furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ca
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm. furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOI'S FEES
❑ Temporary service (residential) $58 -00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing
and justifiable cause demonstrated.
I IIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASI IINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BURTIM CT OWN .' OR ELE 'I'RICAL TRACTOR:
Signature:
Print Name:
Mailing Address: Fe) "PO) e ) 21
Date: 4 CU- (CIr--
Day Telephone: t 6 '3 `R $ 1 - 1 sO q-
CAYeroA.Lvr-I" 0 {R-- 1-1 o l
City State Lip
Date Application Accepted:
1-(to-08"
- l l!/ % 8"
Date Application Expires:
Staff Initials: i , ,re.
H `.4pplicanons•J orms- Apphcanons On Line•4 -2007 - Electncal Permit Application doc
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -056
Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 01/16/2008
Applicant: SARKU JAPAN Issue Date:
Receipt No.: R08 -00889 Payment Amount: $574.00
Initials: JEM Payment Date: 03/25/2008 10:54 AM
User ID: 1165 Balance: $0.00
Payee: D. F. ELECTRIC, INC.
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 24095 574.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 574.00
Total: $574.00
1 •
doc: Receiot -06 Printed: 03 -25 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -056
Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING
Suite No: Applied Date: 01/16/2008
Applicant: SARKU JAPAN Issue Date:
Receipt No.: R08 -00138 Payment Amount: $143.50
Initials: WER Payment Date: 01/16/2008 03:13 PM
User ID: 1655 Balance: $574.00
Payee: WOODBURN CONSTRUCTION
TRANSACTION LIST:
Type Method Description Amount
Payment Check 2635 143.50
ACCOUNT ITEM LIST:
Descript ion
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.0 143.50
Total: $143.50
7321 01/16 9710 TOTAL 1862.13
doc: Receipt -06 Printed: 01 -16 -2008
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
Project: A ✓
t
Type of Inspection: 0,00
Address: 2100
ter{/
Date Called:
Special Instructions:
Date Wanted:
7/1‘
p`.
Requester:
Phone No:
Approved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
•
Inspector:
2-1-16674vtic
Date: Ol j�� ��
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be k
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
(Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
ecog_o$
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: 5 4400
f3
Type of Inspection:
`040
Address:
2-G 00
ti �
Date Called:
Special Instructions:
Date Wanted:
/01
La)..7.1..
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
IA of TO CDLp
- 1.- 1 1M ( ato- F&.
DtF24°" /a L.TC s'45 5
- CAtEcr ul . -14 muck
Inspector:
6tdwec-
Date: O,P oqk
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
INSPECTION RECORD
Retain a copy with permit
ELcc -USA
PERMIT NO.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
(4
Proje'a a"�q,�I,v
Type of Inspection:
-206
7
Address:
Date Called:
Strii/Lfw1 /P At
Special Instructions:
Date Wanted:
/�
P-
Requester:
Phone No:
pproved per applicable codes. D Corrections required prior to approval.
OMMENTS: fit?
014 - C /6 1,1/4, -- 7lr�1.-
T4-
Inspect `ti /I i V f 11(6 `I
Date / /
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
L�
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431 -3670
Project: /4 19 %
X00/2. f / .CT2(/g 77, ,((/ h/t/G
Type of Inspection:
Type
1) T' f (/L t Ix / ,s7//4,/b4;--4.0
pip/ :. 2- 9 iin7 47 /o' - D°Ac /AI 6
Address:
Za9 jeer/felt/7W
Aeate
Called:
i4)7i' IN' 6- Af/ (/- F /..[%
1`- 77rn /o,) 6 01)6- fa� ar,ex C
Special Instructions:
Date Wanted:
t
a.m.
p.m.
Requester:
Phone No:
ElApproved per applicable codes.
orrections required prior to approval.
COMMENTS:
X00/2. f / .CT2(/g 77, ,((/ h/t/G
.x`111 *_,-r-4/1
1) T' f (/L t Ix / ,s7//4,/b4;--4.0
pip/ :. 2- 9 iin7 47 /o' - D°Ac /AI 6
F i l ' . ,Cier Ili L - - O NE7 T /a4J
C M / kill 14)4 w_
0 cigt /)77/ I41b-S f)f c-a OW 7---r
i4)7i' IN' 6- Af/ (/- F /..[%
1`- 77rn /o,) 6 01)6- fa� ar,ex C
c
Inspect
07-k 0) l6
Dater /o !6 r
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670
Project :�� T�n
V!
Type of Inspection: ��j
7 1V �I
DP2o1V'Ae- Sf I Cm ic Ais /GA) ,444
Address:
.(4/-41.0.-v AI-
Date Called:
pecial
Date Wanted:
y /215
/ 7P.m.
a.m.
Requester:
Phone No:
Approved per applicable codes.
orrections required prior to approval.
COMMENTS:
DP2o1V'Ae- Sf I Cm ic Ais /GA) ,444
fit/GM/AN (, icolt sI S/aEi/ 44.N
7741 nSFOfV77
)SM t.- oTh ,c NA. 2f Cr r/4 u! 73
Pillii,W 6- 6-00L.6-45 / 1/
4--42J
Inspep G �„ mow"
n w"
Date: 19/z870f
El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
toF -03"6"
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #1 00, Tukwila, WA 98188
\i‘
PERMIT NO.
(206)431 -3670
Pr ect:
5Y2K i ,ill /9•v
Type of Inspection:
—203
Add reess:
�favU 0/,,•91C E./
L
Date Called:
Special Instructions:
Date Wanted:
`4•
/
a.m.
p.m.
Requester:
Phone No:
roved per applicable codes. ❑ Corrections required prior to approval.
C • MENT5M
0/Z. - ( /t i4 - Arr 4i
Inspecto
Date:
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
kzos-osd
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 9 81 88 (206)431 -3670
Project:
5,q/2.Kl/ i/3)
Type of Inspection: ,..,
7003
v S00,T c( 7 ?
944v Ail.
Date Called:
Special Instructions:
Date Wanted:
]�
(/6
Requester:
Phone No:
W2proved per applicable codes.
COMMENTS: log
❑ Corrections required prior to approval.
Old - wP,�� C_-()Vi/<\
Insp
#1- re-roAAA/chi
Date.-y/.7 /U
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
Marc Brundige
February 27, 2008
City Of Tukwila
Attn: Building Division
6300 Southcenter Blvd., #100
Tukwila, WA 98188
Phone: 206.431.3670
Permit Number: EL08 -056
Project Name: Sarku Japan
Address: 2600 Southcenter Mall, Suite FC -3
Plan Reviewer: Bill Buterbaugh, PH: 206.973.4758
Please find attached 3 complete sets that include the revisions per building department comments noted below. The
following notes describe our response to each item.
Mechanical Comments:
1) Make -up air unit and exhaust fans 1 & 2 are not included in the panel schedule or Toad calculation for Panel
H1. Provide new panel schedule and Toad calculation.
Please see sheets E1.0 & E2.0, revisions have been made and clouded.
2) Provide an average of 1 footcandle illumination at the floor along the entire egress pathway and exit
discharge.
The landlord is responsible for lighting this area and will provide separate documents.
Thank you for your time and attention to this project. Please feel free to contact me with any concerns.
Sincerely,
Marc Brundige
Marc Brundige
5005 W. Royal Lane, Suite 144
Irving, Texas 75063
Voice: 972.929.9226
Fax: 972.929.9061
www.linear-architecture.com
REGISTERED
ARCHITECT
STAT
MARC F SRUNDIGE
WASHINGTON
FILE COPY
CORRECTION
LTR ILA-
EioB-OSb
RECEIVED
FEB 2 8 2008
PERMIT CENTER
2006 Washington State Nonresidential Energy Code Compliance Form
Project Summary
2006 Washington State Nonresidential Energy Code Compliance Forms
PRJ -SUM
Revised July 2007
Project Info
Project Address sarku Japan
Date 1/3/2008
633 South Center Pkwy
For Building Department Use
Tukwila,Wa 98188
Applicant Name: q - Fill out this line on PRJ -SUM
Applicant Address: s - Fill out this line on PRJ -SUM
Applicant Phone: 6 - Fill out this line on PRJ -SUM
rl ` Si( eit
RLE CIPY ELo@ 0510
.F
JAN 17 2008
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address Sarku Japan
Date 1/3/2008
633 South Center Pkwy
For Building Department Use
Tukwila,Wa 98188
Applicant Name: 4 - Fill out this line on PRJ -SUM
Applicant Address: 5 - Fill out this line on PRJ -SUM
Applicant Phone: 6 - Fill out this line on PRJ -SUM
Project Description
❑ New Building ❑ Addition [ J Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
0 Prescriptive ® Lighting Power Allowance ❑ Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
❑ No changes are being made to the lighting
❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2 **
Area in ft2
Allowed x Area
All
Restaurant /fast food
1.30
819.0
1064.7
Front
Fluorescent strip light under counter
11
20.0
220.0
Front
CF down light w/ (1) 26W DTT
17
21.0
357.0
** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
1064.7
Proposed Lighting Wattage
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Kitchen
2x4 2 lamp fluorescent with (2) 32W 18 electronic ball
7
65.0
455.0
Front
Fluorescent strip light under counter
11
20.0
220.0
Front
CF down light w/ (1) 26W DTT
17
21.0
357.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
1032.0
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank.
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary (back)
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Prescriptive Spaces
Occupancy:
(� Warehouses, storage areas or aircraft storage hangers °Other
Qualification Checklist
Note: If occupancy type is "Other' and
fixture answer is checked, the number of
fixtures in the space is not limited by Code.
Clearly indicate these spaces on plans. If
not qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
1521)
u Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts
3. LED lights.
TABLE 15 -1 Unit Lighting Power Allowance (LPA
Use'
LPA` (W /sf)
Use'
LPAz (W /sf)
Automotive facility
0.9
Office buildings, office/administrative areas in
facilities of other use types (including but not limited
to schools hospitals, institutions, museums, banks,
churches)
1.0
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations'
1.0
Cafeterias, fast food establishments',
restaurants/bars'
1.3
Post office
1.1
Dormitory
1.0
Retail'°, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only), school
classrooms, day care centers
1.2
Gymnasia°, assembly spaces°
1.0
Theater, motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group 1 -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses ', storage areas
0.5
Hotel banquet/conference/exhibition hall'•°
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
"laboratory" shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Libraries'
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies' (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
Footnotes for Table 15 -1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Reserved.
7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used.
8) Reserved.
9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W/ft2.
10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points
of track attachment).
c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
2006 Washington State Nonresidential Energy Code Compliance Form
E xterior Lighting Summary
LTG -EXT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Proj Addres sarku Japan
Date 1/3/2008
633 South Center Pkwy
For Building Department Use
Tukwila,Wa 98188
Name: 4 - Fill out this line on PRJ -SUM
Appl. Name s - Fill out this line on PRJ -SUM
Appl. Phone 6 - Fill out this line on PRJ -SUM
Project Description
❑New ❑ Addition Li Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
0 Lighting Power Allowance 0 Systems Analysis
Building Grounds
(luminaires > 100 Watts)
motion Sensor
❑ Efficacy > 60 lumens/VV • Controlled by
❑ Exemption (list)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
❑ No changes are being made to the lighting
fl Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Tradable Maximum Allowed Lighting Wattage
Tradable Locations
Description
Allowed Watts
per ft2 or per If
Area (ft2), perimeter
(If) or # of items
Allowed Watts
x ft2 (or x If)
Tradable Proposed Lighting Wattage
Total Allowed Watts
Use mfgr listed maximum input wattage. For fixtures with hard -w'red ballasts only,
the default table in the NREC Technical Reference Manual may also be used.
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Exterior
Non - Tradable Maximum Allowed Lighting Wattage
Total Proposed Watts
Non - Tradable Locations
Description
Allowed Watts
per ft2 or per If
Area (ft2), perimeter
(10 or # of items
Allowed Watts
x ft2 (or x If)
Non - Tradable Proposed Lighting Wattage
Location
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Proposed Watts may not exceed Allowed Watts for Category
2006 Washington State Nonresidential Energy Code Compliance Form
Exterior Lighting Summary (back)
LTG -EXT
2006 Washington State Nonresidential Energy Code Compliance Forms
TABLE 15 -2
LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS
Revised July 2007
Tradable Surfaces
(Lighting power
densities for uncovered
parking areas, building
grounds, building
entrances and exits,
canopies and overhangs
and outdoor sales areas
may be traded.)
Uncovered Parking Areas
Parking lots and drives
0.15 W /ft2
Building Grounds
Walkways less than 10 feet wide
1.0 W /linear foot
Walkways 10 feet wide or greater
Plaza areas
Special feature areas
0.2W /ft2
Stairways
1.0 W/ft2
Building Entrances and Exits
Main entries
30 W /linear foot of door width
Other doors
20 W /linear foot of door width
Canopies and Overhangs
Canopies (free standing and attached and
overhangs)
1.25 W /ft2
Outdoor Sales
Open areas (including vehicle sales lots)
0.5 W /ft2
Street frontage for vehicle sales lots in
addition to "open area" allowance
20 W /linear foot
Non - Tradable
Surfaces (Lighting
power density
calculations for the
following applications
can be used only for the
specific application and
cannot be traded
between surfaces or
with other exterior
lighting. The following
allowances are in
addition to any
allowance otherwise
permitted in the
"Tradable Surfaces"
section of this table.)
Building Facades
0.2 W /ft2 for each illuminated wall or
surface or 5.0W /linear foot for each
illuminated wall or surface length
Automated teller machines and night
depositories
270 W per location plus 90 W per
additional ATM per location
Entrances and gatehouse inspection
stations at guarded facilities
1.25 W/112 of uncovered area (covered
areas are included in the "Canopies
and Overhangs" section of "Tradable
Surfaces ")
Loading areas for law enforcement,
fire, ambulance and other emergency
service vehicles
0.5 W /112 of uncovered area (covered
areas are included in the "Canopies
and Overhangs" section of "Tradable
Surfaces")
Material handling and associated
storage
0.5 W /ft2
Drive -up windows at fast food
restaurants
400W per drive- through
Parking near 24 -hour retail entrances
800 W per main entry
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting Power Allowance Adjustments
2006 Washington State Nonresidential Energy Code Compliance Forms
LTG -LPA
Revised July 2007
Project Address
Sarku Japan
Date
1/3/2008
Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The
Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet,
12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts
per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM.
Adjusted Lighting Power Allowances (Interior)
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2"
Ceiling Height
for this room
Ceiling Height limit
for this exception"
Adjusted LPA
Watts per ft2
" From Table 15 -1 based on exceptions listed in footnotes
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting,
2006 Washington State
Motor, and Transformer Permit Plans Checklist LTG -CHK
Nonresidential Energy Code Compliance Forms Revised July 2007
Project Address Sarku Japan IDate
1/3/2008
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements
in the 2006 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local controVaccess
Schedule with type, indicate locations
yes
1513.2
Area controls
Maximum limit per switch
n. a.
1513.3
Daylight zone control
Schedule with type and features, indicate locations
n. a.
vertical glazing
Indicate vertical glazing on plans
n. a.
overhead glazing
Indicate overhead glazing on plans
yes
1513.4
Display /exhib /special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features, indicate location
n. a.
(a) timer w/backup
Indicate location
n.a.
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
n.a.
1513.6.1
(a) occup. sensors
Schedule with type and locations
n. a.
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability)
Indicate size of zone on plans
n.a.
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
EXIT SIGNS (Section 1514)
yes I 1514
IMax. watts
'Indicate watts for each exit sign
I
LIGHTING POWER ALLOWANCE (Section 1530 -1532)
yes
1531
Interior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
n.a.
1532
Exterior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
MOTORS (Section 1511)
n.a.
I 1511
IElec motor efficiency
IMECH -MOT or Equipment Schedule with hp, rpm, efficiency
I
I
TRANSFORMERS (Section 1540)
n.a.
I 1540
'Transformers
'Indicate size and efficiency
I
I
If "no" is circled for any question, provide explanation:
4
,Lighting
2006 Washin. ton State Nonresidential Energ Code Com'Hance Form
Motor, and Transformer Permit Plans Checklists l
2006 Washington State Nonresidential Energy Code Compliance Forms
CI
Revised July 2007
Lighting - General Requirements
1513 Lighting Controls: Lighting, including exempt lighting
in Section 1512, shall comply with this section. Where
occupancy sensors are cited, they shall have the features
listed in Section 1513.6.1. Where automatic time switches
are cited, they shall have the features listed in Section
1513.6.2.
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling - height partitions, shall be
provided with lighting controls located within that space. The
lighting controls, whether one or more, shall be capable of
turning off all lights within the space. The controls shall be
readily accessible, at the point of entry/exit, to personnel
occupying or using the space.
EXCEPTIONS: The following lighting controls may be
centralized in remote locations:
1. Lighting controls for spaces which must be used as
a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that
may be controlled from a single switch or automatic control
shall not exceed that which is provided by a 20 ampere circuit
loaded to not more than 80 %. A master control may be
installed provided the individual switches retain their capability
to function independently. Circuit breakers may not be used
as the sole means of switching.
EXCEPTIONS: 1. Industrial or manufacturing process
areas, as may be required for production.
2. Areas less than 5% of the building footprint for
footprints over 100,000 ft2.
1513.3 Daylight Zone Control: All daylighted zones, as
defined in Chapter 2, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight- or occupant- sensing automatic controls,
which control the lights independent of general area lighting.
Contiguous daylight zones adjacent to vertical glazing are
allowed to be controlled by a single controlling device
provided that they do not include zones facing more than two
adjacent cardinal orientations (i.e. north, east, south, west).
Daylight zones under overhead glazing more than 15 feet
from the perimeter shall be controlled separately from daylight
zones adjacent to vertical glazing.
EXCEPTION: Daylight spaces enclosed by walls or
ceiling height partitions and containing 2 or fewer light
fixtures are not required to have a separate switch for
general area lighting_
1513.4 Display, Exhibition and Specialty Lighting
Controls: All display, exhibition or specialty lighting shall be
controlled independently of general area lighting.
1513.5 Automatic Shut -off Controls, Exterior: Lighting for
all exterior applications shall have automatic controls capable
of turning off exterior lighting when sufficient daylight is
available or when the lighting is not required during nighttime
hours. Lighting not designated for dusk- to-dawn operation
shall be controlled by either:
a. A combination of a photosensor and a time switch;
or
b. An astronomical time switch.
Lighting designated for dusk -to -dawn operation shall be
controlled by an astronomical time switch or photosensor. All
time switches shall be capable of retaining programming and
the time setting during loss of power for a period of at least 10
hours.
EXCEPTION: Lighting for covered vehicle entrances
or exits from buildings or parking structures where
required for safety, security, or eye adaptation.
1513.6 Automatic Shut -Off Controls, Interior: Buildings
greater than 5,000 ft2 and all school classrooms shall be
equipped with separate automatic controls to shut off the
lighting during unoccupied hours. Within these buildings, all
office areas less than 300 ft2 enclosed by walls or ceiling -
height partitions, and all meeting and conference rooms, and
all school classrooms, shall be equipped with occupancy
sensors that comply with Section 1513.6.1. For other spaces,
automatic controls may be an occupancy sensor, time switch
or other device capable of automatically shutting off lighting.
EXCEPTIONS: 1. Areas that must be continuously
illuminated (e.g., 24 -hour convenience stores), or
illuminated in a manner requiring manual operation of
the lighting.
2. Emergency lighting systems.
3. Switching for industrial or manufacturing process
facilities as may be required for production.
4. Hospitals and laboratory spaces.
5. Areas in which medical or dental tasks are
performed are exempt from the occupancy sensor
requirement.
1513.6.1 Occupancy Sensors: Occupancy sensors shall
be capable of automatically turning off all the lights in an
area, no more than 30 minutes after the area has been
vacated.
Light fixtures controlled by occupancy sensors shall have a
wall- mounted, manual switch capable of turning off lights
when the space is occupied.
EXCEPTION: Occupancy sensors in stairwells are
allowed to have two step lighting (high -light and low -
light) provided the control fails in the high -light position.
1513.6.2 Automatic Time Switches: Automatic time
switches shall have a minimum 7 day clock and be capable
of being set for 7 different day types per week and
incorporate an automatic holiday "shut -off' feature, which
turns off all loads for at least 24 hours and then resumes
normally scheduled operations. Automatic time switches
shall also have program back -up capabilities, which prevent
the loss of program and time settings for at least 10 hours, if
power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a. is readily accessible;
b. is located so that a person using the device can see the
lights or the areas controlled by the switch, or so that the
area being illuminated is annunciated;
c. is manually operated;
d. allows the lighting to remain on for no more than 2 hours
when an over -ride is initiated; and
e. controls an area not exceeding 5,000 ft2 or 5% of the
building footprint for footprints over 100,000 ft2, whichever is
greater.
1513.7 Commissioning Requirements: For lighting
controls which include daylight or occupant sensing
automatic controls, automatic shut -off controls, occupancy
sensors, or automatic time switches, the lighting controls
shall be tested to ensure that control devices, components,
equipment and systems are calibrated, adjusted and operate
in accordance with approved plans and specifications.
Sequences of operation shall be functionally tested to
ensure they operate in accordance with approved plans and
specifications. A complete report of test procedures and
results shall be prepared and filed with the owner. Drawing
notes shall require commissioning in accordance with this
paragraph.
1514 Exit Signs: Exit signs shall have an input power
demand of 5 Watts or less per sign.
Motors - General Requirements
1511 Electric Motors: All permanently wired polyphase
motors of 1 hp or more, which are not part of an HVAC
system, shall comply with Section 1437.
EXCEPTIONS: 1. Motors that are an integral part of
specialized process equipment.
2. Where the motor is integral to a listed piece of
equipment for which no complying motor has been
approved.
Transformers - General Requirements
SECTION 1540 — TRANSFORMERS
The minimum efficiency of a low voltage dry-type
distribution transformer shall be the Class I Efficiency Levels
for distribution transformers specified in Table 4 -2 of the
"Guide for Determining Energy Efficiency for Distribution
Transformers" published by the National Electrical
Manufacturers Association (NEMA TP -1- 2002).
•
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
February 13, 2008
Tim Pettifer
7650 Birchmount Rd
Markham
Ontario, Canada L3R6B9
RE: CORRECTION LETTER #1
Electrical Permit Application Number EL08 -056
Sarku Japan — 2600 Southcenter Mall, Suite FC -3
Dear Mr. Pettifer,
This letter is to inform you of corrections that must be addressed before your electrical permit can be
approved. All correction requests from the Building Department must be addressed and reflected on your
drawings.
Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding
the attached memo.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that three (3) sets of revised plans,
specifications and /or other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted throuMh the mail or by a messenger service.
if you have any questions, please contact me at (206) 433 -7165.
Sincerely,
4510,4
Brenda Holt
Permit Coordinator
encl
xc: File No. EL08 -056
P:\Permit Center\Correction Letters\2008\ELO8 -056 Correction Ltr NI.DOC
ion
6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665
• •
Building Division Review Memo
Date: February 13, 2008
Project Name: Sarku Japan
Permit #: EL08 -056
Plan Reviewer: Bill Buterbaugh
1. Make -up Air unit and exhaust fans 1 & 2 are not included in the panel schedule or load
calculation for Panel H1. Provide new panel schedule and load calculation.
2. Provide an average of 1 footcandle illumination at the floor along the entire egress
pathway and exit discharge.
•PERMIT COORD COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -056 DATE: 02 -28 -08
PROJECT NAME: SARKU JAPAN
SITE ADDRESS: 2600 SOUTHCENTER MALL FC -3
Original Plan Submittal Response to Incomplete Letter #
X Response to Correction Letter # 1 Revision # After Permit Issued
DEPARTMENTS:
Bui ding !vision
Fire Prevention
Planning Division
Public Works n Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 03 -04 -08
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS RO TING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 04 -01-08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -056 DATE: 01 -17 -08
PROJECT NAME: SARKU JAPAN
SITE ADDRESS: 2600 SOUTHCENTER MALL FC -3
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS: , �3.D
BARN DiVi'sion
Public Works 111
Fire Prevention
Structural
n
Planning Division
Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 01 -22 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROkiTING:
Please Route
Structural Review Required
No further Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 02 -1 9-08
Not Approved (attach comments) 1-4.
DATE:
Permit Center Use Only �j
CORRECTION LETTER MAILED: ` ��
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: /y/
Documents/routing slip.doc
2 -28 -02
• •
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite # 100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http: //www.ci.tukwila.wa.us
Steve Lancaster, Director
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: � Z'Oo Plan Check/Permit Number:
❑ Response to Incomplete Letter #
El Response to Correction Letter # t
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name:
Project Address:
33( s d<A L -�
Contact Person: "--1
Phone Number: 41 (3 ' 3 327-
Summary of Revision:
t■A lr\ Ar
►+ ;2.:EIVED
CIS
OF TUKMI.A
1±b 28 2008
Sheet Number(s):
"Cloud" or highlight all areas of revision including d e of revisio
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on a : )-k -09
iapplicationslfosms- applications on linerevision submittal
nenteit. a_1aanne
Look Up a Contractor, Elects an or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
DFELEI *010D9
Licensee Name
D F ELECTRIC INC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
601940601
Ind. Ins. Account Id
PRESIDENT
Business Type
CORPORATION
Address 1
PO BOX 7205
Address 2
City
TACOMA
County
PIERCE
State
WA
Zip
98406
Phone
2535723704
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
3/29/1999
Expiration Date
3/31/2009
Suspend Date
Separation Date
Parent Company
Previous License
DFELE * *269DM
Next License
Associated License
BENTLA *972QG
Master Electrician Information
License
BENTLA * 972QG
Name
BENTLEY, ANDREW
Status
ACTIVE
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
BENTLEY, ANDREW
AGENT
09/16/2003
BENTLEY, ANDREW
PRESIDENT
09/16/2003
BENTLEY, LYNETTE M
SECRETARY
09/16/2003
•
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= DFELEI *010D9 03/25/2008
WESTFIELD SOUTHCENTER
633 SOUTHCENTER PARKWAY
TUKWILA, WA 98188 -2888
SPACE# FC -3
EY P LA\ o
SARKU JAPAN
SPACE# FC -3
LEVEL: 02 OF 3
SO. FT.: 816
PROJECT INFORMATION:
OWNER:
SARKU JAPAN
7650 BIRCHMOUNT ROAD,
MARKHAM, ONTARIO
CANADA L3R 6B9
TEL: (905) 474 -0710
FAX: (905) 474 -0421
PROJECT MANAGEMENT:
SJ DESIGN BUILD INC.
7650 BIRCHM❑UNT ROAD,
MARKHAM, ONTARIO
CANADA L3R 6B9
TEL: (905) 415 -5700
FAX: (905) 474 -0421
ATTN.% TIM PETTIFER
- DIRECTOR, CONSTRUCTI ❑N
ARCHITECT:
LINEAR ARCHITECTURE
5005 WEST ROYAL LANE, SUITE 144
IRVING, TX 75063
TEL: (972) 929 -9226
FAX (972) 929 -9061
ATTN.: PHILIP KEMERY / MERCI KEMERY
LANDLORD:
WESTFIELD CORP❑RATI ❑N
14TH FLOOR
11601 WILSHIRE BLVD.
LOS ANGELES, CA 90025
TEL.: (310) 893 -4761
FAX. (310) 575 -5991
ATTN.: JOSH KIMMEL - PROJECT MANAGER
MALL PROPERTY MANAGEMENT:
WESTFIELD SOUTHCENTER
633 SOUTHCENTER PARKWAY
TUKWILA, WA 98188 -2888
TEL.: (206) 246 -0423
ATTN.: OPERATIONS MANAGER
BUILDING DEPARTMENT:
CITY OF TUKWILA
6300 SOUTHCENTER BLVD. #100
TUKWILA, WA 98188
TEL,: (206) 431 -3670
FIRE DEPARTMENT:
444 ANDOVER PARK EAST
TUKWILA, WA 98188
TEL.: (206) 575-4404
EMAIL: tukfdadri@ci,tukwi ; a.wa,us
HEALTH DEPARTMENT:
WASHINGT ❑N STATE DEPARTMENT OF HEALTH
101 ISRAEL RD. SE
TUMWATER, WA 98501
TEL,; (360) 236 -4501
TENANT:
TENANT: SARKU JAPAN
ADDRESS: WESTFIELD SOUTHCENTER
SPACE# FC3
633 SOUTHCENTER PARKWAY
TUKWILA, WA 98188 -2888
APPLICABLE CODES
CONSTRUCTION TYPE
EXISTING CONSTRUCTION TYPE:
TYPE II — B — UNPROTECTED NONCOMBUSTIBLE
FULLY SPRINKLED
OCCUPANCY GROUP
PRIMARY OCCUPANCY:
M — MERCANTILE
APPLICABLE CODES
BUILDING — 2006 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS
MECHANICAL — 2006 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE
AMENDMENTS
PLUMBING — 2006 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS
ELECTRICAL — 2005 NATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS
ACCESSIBILITY — CHAPTER 11 IBC AND OTHER INTERNATIONAL BUILDING CODE REQUIREMENTS
FOR BARRIER —FREE DESIGN ACCESS INCLUDING ICC/ ANSI A117.1 -- 2003
ENERGY — 2006 WASHINGTON STATE ENERGY CODE
FIRE — 2006 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS
DRAWING INDEX
C -1 COVER SHEE I
C -2 ROOM FINISH & RESPONSIBILITY SCHED., WALL LENGEND
A -1 REFL. CLG. PLAN & FLOOR
A -2 ELEVATIONS
A -3 ELEVATIONS
AD -1
AD -2
AS -1
K -1
K -2
PLAN
DETAILS
DETAILS
ARCHITECTURE SPECIFICATIONS
& NOTES
EQUIPMENT PLAN, COUNTER CUT —OUT, ELECTRICAL
ROUGH —IN PLANS/ LOCATIONS
EQUIPMENT SCHEDULE
H -1 HOOD DRAWINGS
H -2 HOOD DRAWINGS
H -3 HOOD DRAWINGS
M -1 MECHANICAL PLAN & SCHEDULES
E -1 POWER & LIGHTING PLANS
E -2 ELECTRICALS DETAILS & PANEL SCHEDULES
P -1 PLUMBING PLANS
P -2 PLUMBING DETAILS
SEPARATE PERMIT
REQUIRED
dhiecranical
t Electrical
*Plumbing
SIGas Piping
City of Tukwila
BUILDING DIVISION
& PLUMBING
REVISIONS
NO changes shall be made to the scope
of work without prior approval of
Tukwila Building Division
NOTE: Revisions will require a new plan yubrn ►I
and may include additional plan rco' k
FILE COPY
Permit No,
Mar review approval Is subject to errors and omisskins.
Approval of construction doaunerds does not authorize
the violatlon of any adopted code or ordnance. �:
of approved Fief.
By
Date:
City of Tukwila
BUILDING DIVISION
APPROVED P!
;ANGED, MODIFIED OR ALTERED
WITHOUT AUTHORIZATION FROM THE BUILDING
07I ^ :AI., ALL WORK SHALL BE DONE IN
ACCORDANCE WITH THE APPROVED PLANS AND
I5
'1.13,;aCT TO FIELD INSPECTIONS
ABBR
T_VIAT1 O
\Se
A.F.F.
ACT.
ADJ.
A.C.
ALT.
ALUM.
A.B.
&
APPROX.
Q
AWN.
B.C.
B.P.
BM.
BLK.
B.S.
B.W.
N.
BRK.
BLDG.
CAB.
CPT.
C.I.
C.B.
CLG.
CEM.
CTR.
C.T.
CHBD.
C.O.
CLO.
COL
COM.
CONC.
CONST.
C.M.U.
CONT.
CONTR.
C.J.
C.TOP
DEMO.
DEPART.
DTL.
DIA.
DIM.
DR.
DTA.
DT.S.
DN.
DWG.
D.F.
EA.
E.
ELEC.
E.C.
E.H.D.
E.W.C.
ELEV.
ENCL.
EQ.
EQUIP.
EXIST,
E.J.
EXP.
EXT.
ABOVE FINISH FLOOR
ACOUSTICAL
ADJUSTABLE
AIR CONDITION / CONDIUONED/
CONDITIONER /CONDITIONING
ALTERNATE
ALUMINUM
ANCHOR BOLT
AND
APPROXIMATELY
AT
AWNING
BASE CABINET
BASE PLATE
BEAM
BLOCK
BOTH SIDES
BOTH WAYS
BOTTOM
BRICK
BUILDING
CABINET
CARPET
CAST IRON
CATCH BASIN
CEILING
CEMENT
CENTER
CERAMIC TILE
CHALKBOARD
CLEAN OUT
CLOSET
COLUMN
COMBINATION
CONCRETE
CONSTRUCTION
CONCRETE MASONRY UNIT
CONTINUOUS
CONTRACTOR
CONTROL JOINT
COUNTER TOP
DEMOLITION
DEPARTMENT
DETAIL
DIAMETER
DIMENSION
DOOR
DOVETAIL ANCHOR
DOVETAIL SLOT
DOWN
DRAWING
DRINKING FOUNTAIN
EACH
EAST
ELECTRICAL
ELECTRICAL CONTRACTOR
ELECTRIC HAND DRYER
ELECTRIC WATER COOLER
ELEVATION
ENCLOSURE
EQUAL
EQUIPMENT
EXISTING
EXPANSION JOINT
EXPOSED
EXTERIOR
E.G.C.B. EXTERIOR GYPSUM CRAG
BOARD
F.O.S.
FT.
F.N.D.
F.N.V.
FIN.
FIN. OPNG.
F.E.
F.E.C.R.
F.H.
F.R.P.
F.R.T.
FL
F.D.
F.P.
FTG.
F.M.
GALV.
GA.
G.C.
GL
G.B.
G.W.B.
GYP.
HC.
HDW.
HT.
H.
H.C.
H.M.
HORIZ.
IN.
INCL
I.D.
INSUL.
JT.
JST.
LAM.
LL
LAV.
L.
MGR.
M.H.
MFR.
MAS.
M.O.
MAT'L.
MAX.
MECH.
MT.
M.F.
M.S.
M.R.D.
MIN.
M.
MISC.
M.R.
M.B.H.
MTD.
N.
N.I.C.
N.T.S.
NO.
FACE OF STUD
FEET
FEMININE NAPKIN DISPOSAL
FEMININE NAPKIN VENDOR
FINISH
FINISH OPENING
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
RECESSED
FIRE HYDRANT
FIRE RETARDANT PANEL
FIRE RETARDANT TREATED
FLOOR
FLOOR DRAIN
FLUSH PANEL
FOOTING
FRAMED MIRROR
GALVANIZED
GAUGE
GENERAL CONTRACTOR
GLASS
GRAB BAR
GYPSUM WALLBOARD
GYPSUM
HANDICAPPED
HARDWARE
HEIGHT
HIGH
HOLLOW CORE
HOLLOW METAL
HORIZONTAL
INCH
INCLUDE
INSIDE DIAMETER
INSULATION
JOINT
JOIST
LAMINATED
LANDLORD
LAVATORY
LONG
MANAGER
MANHOLE
MANUFACTURER
MASONRY
MASONRY OPENING
MATERIAL
MAXIMUM
MECHANICAL
METAL
METAL FRAME
METAL STUD
METAL ROOF DECK
MINIMUM
MIRROR
MISCELLANEOUS
MOISTURE RESISTANT
MOP AND BROOM
HOLDER
MOUNTED
NORTH
NOT IN CONTRACT
NOT TO SCALE
NUMBER
0.C.
OPNG.
OPP. HAND
0.D.
PR.
P.T.D.
P.T.H.
P.COL
PLAS.
P. LAM.
PLUMB.
P.C.
PLYWD.
P.T.
PHONE
Q.T.
R.
RECT.
REINF.
REQ'D.
REV.
R.D.
RM.
R.O.
S.C.O.F.
S.N.D.
SCH.
SNT.
SECT.
SHT.
SHO.
SHO.C.
SHO.H.
SIM.
S.D.
S.H.
S.C.
S.
SPECS.
SQ.
SQ.FT.
S.S.
STD.
STL
STR.
S.M.S.
SUSP.
SYS.
TKBD.
T.C.
T.P.H.
T.& G.
T.B.
TYP.
U.
U / S
V.T.R.
VERT.
V.T.
W.R.
W.C.
W.H.
W.P.
W.
W/.
W /0.
WD.
ON CENTER
OPENING
OPPOSITE HAND
OUTSIDE DIAMETER
PAIR
PAPER TOWEL
DISPENSER
PAPER TOWEL HOLDER
PIPE COLUMN
PLASTER
PLASTIC LAMINATE
PLUMBING
PLUMBING CONTRACTOR
PLYWOOD
PRESSURE TREATED
TELEPHONE
QUARRY TILE
RADIUS
RECTANGULAR
REINFORCEMENT
REQUIRED
REVISION
ROOF DRAIN
ROOM
ROUGH OPENING
SLIP COEFFICIENT OF FRICTION
SANITARY NAPKIN DISPOSAL
SCHEDULE
SEALANT
SECTION
SHEET
SHOWER
SHOWER CONTROLS
SHOWER HEAD
SIMILAR
SOAP DISPENSER
SOAP HOLDER
50LID CORE
SOUTH
SPECIFICATIONS
SQUARE
SQUARE FEET
STAINLESS STEEL
STANDARD
STEEL
STRUCTURAL
STRUCTURAL METAL
STUD
SUSPEND
SYSTEM
TACKBOARD
TENANT C0- ORDINATOR
TOILET PAPER HOLDER
TONGUE AND GROOVE
TOWEL BAR
TYPICAL UNLESS
OTHERWISE NOTED
URINAL
UNDERSIDE
VENT THROUGH ROOF
VERTICAL
VINYL TILE
WASTE RECEPTACLE
WATER CLOSET
WATER HEATER
WATER PROOF
WEST
WIDTH
WITH
WITHOUT
WOOD
(SY
v
BOSS LEG
SECTION CUT
INDICATI ❑N
PLAN DETAIL
INDICATION
ELEVATION
INDICATION
DOOR
IDENTIFICATION
FINISH INDICAT ❑R
EQUIPMENT SYMBOL
FURNISHING &
ACCESSORIES
INDICATOR
GENERAL
NOTES
ELEVATION TARGET
SECTION NUMBER
SHEET NUMBER
DETAIL AREA
DETAIL NUMBER
SHEET NUMBER
ELEVATION NUMBER
SHEET NUMBER
NOTES WHICH APPLY
TO SPECIFIC ITEMS
ON DRAWINGS WHERE
INDICATED.
3). NOTES WHICH APPLY
TO ALL DRAWINGS.
0, -0' — ELEVATI ❑N
ABOVE
FIN. FLR71"---- SURFACE
DESCRIPTI ❑N
L.L.
CENTERLINE
DIAMETER
PLATE
LEASE LINE
Public Works, Building Division
PERMIT NUMBER
JAN 16 2008
COVER SHEET
ELO&' 056
PRELIMINARY DWGS. FOR L.L. APPROVAL
LL COMMENTS
m
N
0
2
w
Q
'<.<1<<<2
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AT THE JOB SITE AND
NOTIFY THE ARCHITECTS OF ANY
DIMENSIONAL ERRORS, OMISSIONS
OR DISCREPANCIES BEFORE
BEGINNING OR FABRICATING ANY
WORK
DO NOT SCALE DRAWINGS
U
U
rcs
E
0
0
1- 0
mam
z�
=Oct
0 n
mzo
o
r- M V
O N
i
LO
0 0
0
0
0
0.
0
0
w
w
CO
''%_.
SINi CC
z ACV
Li_l C._.) I CO
CO
Li j
O M, w °'
0 L`H-
w a:
GO c0
JOB NUMBER
21
SHEET NUMBER
c1
FILE COPY
DATE OF ORIGINAL ISSUE
24 SEPTh18E 2 2+Dc2)7
STATISTICS
DESCRIPTION
SYMBOL AVG
MAX/MIN
A VG/M IN
CALC ZONE 41
13.0:1
6.8:1
CIRCUIT EMERGENCY/EXIT
LIGHTING ON UNSWITCHED LEG
OF LOCAL LIGHT CIRCUIT_
1.7 +1.7 +1.5 +1.3 +1.1 +0.9
2.5 2_� i i 2.1 1/
1/ \I
E" ___A
+ + + + + + +
2.0 2.3 _ 2.6 2.6 2.5 2.3 2.0 1.8
+ + +
1.0 0.8 0.7
+ + +
1.2 1.0 0.9
+ + + + + + + + + +
1.4 1.8 2.1 2.4 2.5 2.5 2.4 2.3 2.2 1.9
SEE SASE BUILDING DRAWINGS FOR EGRESS
LIGHTING OUTSIDE OF THIS TENANTS SPACE_
OTE S 5' SYM OL
PROVIDE JUNCTION BOX WITH ASSOCIATED 120V ,r/20 AMP CIRCUIT FOR MENU
SOX AND PICTURE BOARD LIGHT BOXES. SEE ARCHITECTURAL DETAILS FOR
EXACT MOUNTING REQUIREMENTS. SEE LIGHT FIXTURE SCHEDULE TYPES "C' AND "D"
FIXTURE.
120V ,1P/30 AMP NON FUSED NEMA 3R DISCONNECT ON ROOF FOR REMOTE
FREEZER AND COOLER CONDENSING UNITS. VERIFY LOCATION.
120V ,1P/30 AMP NEMA 3R DISCONNECT AT FREEZER AND COOLER EVAPORATOR
BLOWERS
JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR FREEZER/COOLER
LIGHTS AND DOOR HEATER_ VERIFY LOCATION AND CONNECTION REQUIREMENTS.
`: I 480V 3P/20 AMP DISCONNECT ON ROOF AT EF -1 AND EF -2. SEE EXHAUST PAN
SCHEDULE FOR AND CONTROL BOX WIRING DIAGRAM ON DRAWING SHEET H2
ADDITIONAL INFORMATION.
n 4S0V ,3P/20 AMP DISCONNECT ON ROOF AT MUA -1. SEE EXHAUST FAN SCHEDULE
�/ FOR AND CONTROL BOX WIRING DIAGRAM ON DRAWING SHEET 142 ADDITIONAL
INFORMATION_
PROVIDE JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR ANSUL
SYSTEM CONNECTION. CONTRACTOR MUST VERIFY INTERLOCK REQUIREMENTS FOR
AN5UL AND EXHAUST SYSTEMS.
p PROVIDE JUNCTION BOX AND ASSOCIATED 120v ,1P/20 AMP CIRCUIT FOR HOOD
LIGHTS. VERIFY MOUNTING REQUIREMENTS_
n 30 KVA TRANSFORMER SUSPENDED FROM STRUCTURE ABOVE_ SEE ELECTRICAL
�J SERVICE RISER FOR ADDITIONAL INFORMATION_ VERIFY LOCATION AND
MOUNTING REQUIREMENTS_
11,-;31 450V ,3P/20 AMP DISCONNECT AND ASSOCIATED CIRCUIT FOR WATER HEATER
CONNECTION_ VERIFY MOUNTING HEIGHT_
11 ELECTRICAL PANELS "A" AND '14' . SEE ELECTRICAL SERVICE RISER AND
PANEL SCHEDULE FOR ADDITIONAL INFORMATION.
12 PROVIDE JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR
SIGNAGE_ VERIFY LOCATION . CIRCUIT THROUGH TIME CLOCK
13 120V ,1P/20 AMP GFI RECEPTACLE IN WP ENCLOSURE FOR HVAC
MAINTANENCE.
+ + + + + + + + +
,0.8 1.0 1.1 1.3 1.6 1.9 2.2 2.4
CIRCUIT EMERGENCY/EXIT
LIGHTING ON UNSWITCHED
LEG OF LOCAL LIGHT
CIRCUIT_
NUMBER INDICATES -
FOOT CANDLE LEVEL
AT FLOOR
(TYPICAL)
0 4 +0.6 +0.7 +0.9 +1.1
1.4 1.5 1.4 1.2 1.1 1.0
'EM'
+1.0 +1.2 1.3 * +0. +0.8
PRELIMINARY DWGS. FOR L.L. APPROVAL
m
LL COMMENTS
CITY COMMENTS
CITY COMMENTS
REVISIONS
N
cn
O
CO
d
Cr)
co
0
O
CO
O
CV
N
O
<KK<T'<12
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AT THE JOB SITE AND
NOTIFY THE ARCHITECTS OF ANY
DIMENSIONAL ERRORS, OMISSIONS
OR DISCREPANCIES BEFORE
BEGINNING OR FABRICATING ANY
WORK
DO NOT SCALE DRAWINGS
14 480v 3P/30 AMP NEMA 3R NON FUSED DISCONNECT ON ROOF AT RTU. VERIFY
LOCATION. SEE ELECTRICAL RISER DIAGRAM FOR ADDITIONAL INFORMATION.
15 PROVIDE JUNCTION BOX FOR CONNECTION OF TYPE 'A" TRAY RAIL LICxHTINCx. SEE
ARCHITECTURAL DETAILS FOR EXACT LOCATION.
16 PROVIDE JUNCTION BOX WITH ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR
JAPANESE SCREEN LIGHTING SEE ARCHITECTURAL DETAILS FOR EXACT MOUNTING
REQUIREMENTS.
JUNCTION BOX AND 480V 3P/20 AMP CIRCUIT FOR EXHAUST FAN CONTROL PANEL.
SEE WIRING DIAGRAM ON DRAWING SHEET 142.
EGRESS LIG�ITINC FLAN
SCALE: 1/4' = 1'.0'
TRAY RAIL LIGHTING -I
SEE DETAIL I /AD1 AND
2/4D1 FOR EXACT
LOCATION
02
LIG - 4TINCB FLAN
PNL "A"
FNL "H"
SERVICE
DISCONNECT
AS
410
IS I 414
45
14 14,16,18
413
r
I
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
42
142,4,6 �`
N.
E1-9-1 \ \ N.
120V CONTROL
CIRCUIT FROM
CONTACTS AT
CAPTIVE AIR
HOOD / ANSUL
CONTROL
PANEL.
SEE EXHAUST
SYSTEM DETAIL
DRAWINGS HI
AND H2 FOR
ADDITIONAL
INFO1�1 1ATION.
1-11 • j
1-13 • J
H5 • J
141 • .�
I-19 •
1-111 •
120V_
R� COIL
f2OV
60 AMP 6 POLE
ELECTRICALLY
HELD
CONTACTOR W/
120V COIL. ALL
CONTACTS TO BE
NORMALLY
CLOSED.
GRIDDLE 1
GRIDDLE 2
LIGHT � f X T l SCHEDULE
TYPE DESCRIPTION MOUNTING LAMPS
'A' 2X4 TROFFER WITH ACRYLIC LENS RECESSED 2 -P32T8
METALUX *2G- 232419- 120v. -EB81
4 ►.- IT_� 14 #2GT - -1/4-
' AE' 2X4 TROFFER WITH ACRYLIC LENS AND EMERGENCr RECESSED 2 -F32TS
BATTERY PACK. METALUX *2G- 232A1g- 120V- EM -ES2
(ALTERNATE: LITHONIA "2GT- 232419 -1/4- 120 -GEB)
6" 4 URE REG�ED�DOWN� (1� � RECESSED 26W DTT
DTT. 120v. PROVIDE WITH LOW IRON SAFTEY GLASS e
LENSES_ 1� /��� J ����
'C' ME LIGHT _ 120V . SURFACE (6)F20 RSTP
CUSTOM MODE FIXTURE
COORDINATE WITH ARCHITECTURAL DRAWINGS FOR
NUMBER OF BOXES TO BE INSTALLED.
' D' PICTURE BOARD LIGHT 120v SURFACE (6�F20 RSTP
CUSTOM MADE FIXTURE
COORDINATE WITH ARC1- IITECTURAL DRAWINGS FOR
NUMBER OF BOXES TO BE INSTALLED_
'E' SLENDER LIGHT SL24F RECESSED 20W
COMPACT FLUORESCENT WITH BUILT IN ELECTRONIC
BALLAST. FIXTURE USES * SL24 -CW -BULB
COOL WHITE 20 WATT LAMPS
'X' LITHON14, LHQMSWIRN LED EXIT SIGN/EMERGENCY, SURFACE INCLUD�1�
COMBO UNIT. WITH BATTERY BACK -UP_ rr
'EM' LITHONI4, ELM2, WALL MOUNTED, DUAL HEADS. SURFACE INCLUDED
EMERCaENCY LIGHT W /90 MINUTE BATTERIES.
4_4
.2c2-*
V.�
tp.o
c
r U
Q
E
0
Lr) LID t -d
N m N
• L.0 C4 r
w
L
ro
�` Q1 6-; rtd
• `xx n rn c
LC obc� x
.
o E 0
a C
CONTACTOR
LC -1
60 AMP 6 POLE
ELECTRICALLY
HELD >
CONTACTOR W/
120v COIL. ALL
CONTACTS TO BE
NORMALLY
CLOSED.
0
0
1- 0
zto
x0 CC
CC
0
moo
Lc) ¢Q
EMAIL: sJdesign ®sarkujapon.cam
NOTE:
KITCHEN FIRE SUPRESSION SYSTEM MUST BE CONNECTED
TO LANDLORDS MAIN FIRE ALARM BY LANDLORDS
APPROVED FIRE ALARM CONTRACTOR AT TENANTS
EXPENSE.
LANDLORDS
EQUIPMENT
ENCLOSURE----
- 14,I6,1S
H13 --•
1415
Hl-1
415
425
48 �--
GRIDDLE 3
NOTE:
FRONT SERVERY LIGHTS AND MAIN SIGN MUST SE CIRCUITED
THROUGH TIME CLOCK SET TO LANDLORDS SCHEDULE.
RICE WARMER * SA
REFRIGERATED BASE *11,4
1-100D LIGHTS
w
W
U
0
(f)
a
w
(1)
w
H- 14,16,18
CONTACTOR
LC -2
JOB NUMBER
J.21
O3 ELECTRICAL AUTO SHUTDOUJN CONTACTOR DETAIL
H- 20,22 ,24
SCALE: 1/4' = l' =0'
NO SCALE
CORRECTION
QTR#
ELO 9'O5&
SHEET NUMBER
RECEIVED
FEB 2 8 2008
PERMIT CENTER
PL,l6vR AND
PLANS
1
FILE tWY
DATE OF ORIGINAL ISSUE
24 SEPTMSER 2007
_ _ _.-/
LIGHT � f X T l SCHEDULE
TYPE DESCRIPTION MOUNTING LAMPS
'A' 2X4 TROFFER WITH ACRYLIC LENS RECESSED 2 -P32T8
METALUX *2G- 232419- 120v. -EB81
4 ►.- IT_� 14 #2GT - -1/4-
' AE' 2X4 TROFFER WITH ACRYLIC LENS AND EMERGENCr RECESSED 2 -F32TS
BATTERY PACK. METALUX *2G- 232A1g- 120V- EM -ES2
(ALTERNATE: LITHONIA "2GT- 232419 -1/4- 120 -GEB)
6" 4 URE REG�ED�DOWN� (1� � RECESSED 26W DTT
DTT. 120v. PROVIDE WITH LOW IRON SAFTEY GLASS e
LENSES_ 1� /��� J ����
'C' ME LIGHT _ 120V . SURFACE (6)F20 RSTP
CUSTOM MODE FIXTURE
COORDINATE WITH ARCHITECTURAL DRAWINGS FOR
NUMBER OF BOXES TO BE INSTALLED.
' D' PICTURE BOARD LIGHT 120v SURFACE (6�F20 RSTP
CUSTOM MADE FIXTURE
COORDINATE WITH ARC1- IITECTURAL DRAWINGS FOR
NUMBER OF BOXES TO BE INSTALLED_
'E' SLENDER LIGHT SL24F RECESSED 20W
COMPACT FLUORESCENT WITH BUILT IN ELECTRONIC
BALLAST. FIXTURE USES * SL24 -CW -BULB
COOL WHITE 20 WATT LAMPS
'X' LITHON14, LHQMSWIRN LED EXIT SIGN/EMERGENCY, SURFACE INCLUD�1�
COMBO UNIT. WITH BATTERY BACK -UP_ rr
'EM' LITHONI4, ELM2, WALL MOUNTED, DUAL HEADS. SURFACE INCLUDED
EMERCaENCY LIGHT W /90 MINUTE BATTERIES.
4_4
.2c2-*
V.�
tp.o
c
r U
Q
E
0
Lr) LID t -d
N m N
• L.0 C4 r
w
L
ro
�` Q1 6-; rtd
• `xx n rn c
LC obc� x
.
o E 0
a C
CONTACTOR
LC -1
60 AMP 6 POLE
ELECTRICALLY
HELD >
CONTACTOR W/
120v COIL. ALL
CONTACTS TO BE
NORMALLY
CLOSED.
0
0
1- 0
zto
x0 CC
CC
0
moo
Lc) ¢Q
EMAIL: sJdesign ®sarkujapon.cam
NOTE:
KITCHEN FIRE SUPRESSION SYSTEM MUST BE CONNECTED
TO LANDLORDS MAIN FIRE ALARM BY LANDLORDS
APPROVED FIRE ALARM CONTRACTOR AT TENANTS
EXPENSE.
LANDLORDS
EQUIPMENT
ENCLOSURE----
- 14,I6,1S
H13 --•
1415
Hl-1
415
425
48 �--
GRIDDLE 3
NOTE:
FRONT SERVERY LIGHTS AND MAIN SIGN MUST SE CIRCUITED
THROUGH TIME CLOCK SET TO LANDLORDS SCHEDULE.
RICE WARMER * SA
REFRIGERATED BASE *11,4
1-100D LIGHTS
w
W
U
0
(f)
a
w
(1)
w
H- 14,16,18
CONTACTOR
LC -2
JOB NUMBER
J.21
O3 ELECTRICAL AUTO SHUTDOUJN CONTACTOR DETAIL
H- 20,22 ,24
SCALE: 1/4' = l' =0'
NO SCALE
CORRECTION
QTR#
ELO 9'O5&
SHEET NUMBER
RECEIVED
FEB 2 8 2008
PERMIT CENTER
PL,l6vR AND
PLANS
1
FILE tWY
DATE OF ORIGINAL ISSUE
24 SEPTMSER 2007
P4NFLo SCHEDULE
PANEL. SCHEDULE A IQKAIG
ID <,41G
NOTES:
NOTES:
DESCRIPTION
ITEM
NO.
I
a_
TRIP
AMPS
TOTAL
WATTS
A 5 C
TOTAL
WATTS
TRIP
AMPS
o
a_
DESCRIPTION
ITEM
No.
NOTES:
SOFT DRINK DISPENSER
19A
GRIDDLE CKT 1
IF
3
30
6000
1
3
$
1
9
11
13
1��16
1
I9
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
X4426
20
3
RTU
•
HACK
'
L
CA51 -4 REGISTER
2
1
20
250
660
20
1
MEAT SLICER
6000
4426
•
•
DRINK CARBONATOR
30
"11
20
1500
1440
4
6
1
PASS THROUGH REFRIGERATOR
15
L
6000
4426
1
20
600
1200
20
1
COOLER/LIGHTSMEATER
1
•
i
S
GRIDDLE CKT 2
IF
3 30
6000
8320
45
3 TRANSFER 'A'
20
1
��
17/18
L
•
•
MEAT MIXER
29
6000
86-15
1632
1800
20
1
FREEZER CONDENSER
11
L
��
ANSUL /WOOD LIGHTS
10
12
1
20
1200
1800
20
1
COOLER CONDENSER
6000
5122
•
RICE WARMER
SA
1
11
1000
G IDDLE 3
1S
3 25
4000
1101
20
3 EF -1 / MUA -1
WCP
HOT FOOD
WELL
65
14
2
30
1500
4000
114000
w
,
I
v
1500
1420
20
1
•
L
ICE MACHINE
208
1
20
II
I
20
1
51GN
WATER HEATER
2213
3 20
2000
395
20
3
! -2
54
WCP
V
•�•1
20
SPACE
2000
395
SPACE
21
23'1.•
22
24
W
•
V
2000
395
1
20
1200
120
20
I
RECEPTACLE
TOTAL 'A' 32842 MAI14 200 AMP MAIN LUGS ONLY
4 VOLTS 217/480
e
TOTAL 'S' 3311
TOTAL 'C' 32644
98683 4
TOTAL
ELECTRICAL LOAD ANALYSIS
WCP= CIRCUIT THROUGH HOOD CONTROL
I
LIGHTING /51GNAGE AT 125%= 5.98 KVA
FANS AT 125%. 1.81 KVA
PANEL_ SEE DRAWING SWEET 1-12 FOR
ADDITIONAL INFORMATION.
THERMOSTATICALLY CONTROLLED
KITCHEN EQUIPMENT AT 650 = 38.89 KVA 4
MISC. EQUIPMENT AT 100% = 8.49 KVA
WATER HEATER ATI00%= 6.00 KW
HVAC 1B 100% 1321 KW
TOTAL LOAD= 80.59 KVA (91 AMPS)
NOTE:
CONDUIT AND CONDUCTORS
FROM LANDLORD PROVIDED
DISCONN^Ct IN LANDLORDS
ELECTRICAL ROOM TO
LANDLORD PROVIDED
DISCONNECT N TENANTS SPACE
15 5r LANDLORD.
NEW 211/480V 200 AMP
METER AND SASE_
LANDLORDS
ELECTRICAL
ROOM
a
LANDLORD PROVIDED 480v
3P 200 AMP FUSED SERVICE
DISCONNECT IN LANDLORDS
ELECTRICAL ROOM.
(1) # 6 CU GROUND TO
SUILDING GROUNDING
SYSTEM .VERIFY
REQUIREMENT.
TENANTS
SPACE
4SOV, 3P /30 AMP NEMA 3
FUSED DISCONNECT AT
ROOF MOUNTED MAKE UP
AIR FAN MUA -1
TENANTS CONTRACTOR
SHALL PROVIDE
(3) *3/0 CU THWN
(1) # CU GROUND
(1) 2' CONDUIT
LANDLORDS SHALL —
PROVIDE
(3) *3/0 CU THWN
(1) *4 CU GROUND
(1) 2' CONDUIT
(3) *10 CU THWN
(1) #10 CU GROUND
(1) 3/4° CONDUIT
MU411
EF1
1
480V, 3P/30 AMP NEMA 3R
NON FUSED DISCONNECT AT
ROOF MOUNTED EXHAUST
FAN EF -1 AND EF -2 _
4830V, 3F'/30 AMP NEMA 3R
NON FUSED DISCONNECT AT
ROOF MOUNTED HVAC UNIT
RTU -1.
EP2
J
RTU
J
'(3) 010 CU TI-4WN
(1) *12 CU GROUND
(1) 3/4' CONDUIT
REVIEWED FOR
CODE COMPLIANCE
NFPA70dNEC
Mkt 21 2000
LANDLORD PROVIDED 480v
,3P 200 AMP FUSED SERVICE
DISCONNECT N TENANTS
SPACE FUSED AT 200 AMPS_
(1)* 4 CU GROUND TO
BUILDING GROUNDING
SYSTEM .VERIFY
REQUIREMENT_
PANEL "1•-1
3P/4S
(3) % CU THWN
(1) % CU GROUND
(1) 1' CONDUIT
Oty Of Tukwila
ILDDNG D I, N
1--1000
CONTROL
PANEL
TIMECLOCK
NEW 211/450V , 3 PHASE
PANEL 1-I' WITH 200 AMP
MAIN LUGS ONLY. SEE
PANEL SCHEDULE FOR
ADDITIONAL INFORMATION.
01
c
s
'VI0
30 KVA XEMR
PANEL °A°
NO SCALE
NEW 120/208v , 3 PHASE PANEL 'A°
WITH 100 AMP MAIN CIRCUIT BREAKER
SEE PANEL SCHEDULE FOR
ADDITIONAL INFORMATIOiL
PROVIDE (4) *1 CU THWN AND
(1)* 6 CU GROUND IN 1 -1/2'
CONDUIT_
(1) * 6 CU GROUND TO
BUILDING GROUNDING
SYSTEM _VERIFY
REQUIREMENT.
LOB os&
rLEC RIC4L
DE-T-4 LS AND
PANLL S k=
RECEIVE
FEB 2 8 2008
PERMIT CENT&
PRELIMINARY DWGS. FOR L L. APPROVAL
0
TI-
N
0
LL COMMENTS
0
0
0
0
CITY COMMENTS
co
0
0
0
CITY COMMENTS
co
0
CV
N
0
m
w
a
0
<1.<1 <1<zr<g
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AT THE JOB SITE AND
NOTIFY THE ARCHITECTS OF ANY
DIMENSIONAL ERRORS, OMISSIONS
OR DISCREPANCIES BEFORE
BEGINNING OR FABRICATING ANY
WORK
DO NOT SCALE DRAWINGS
EIt IL: sjdesign�sarkujapan.cam
L
z
w
0
0
(1)
J
W
Li
U)
CO
›- CO
CO
N
a I
CO
CC 00
Z
�7w
Q
0
Q rr)
O ro
cnco 1—
JOB NUMBER
7.21
i
SHEET NUMBER
DATE OF ORIGINAL ISSUE
24 SEFTM35Eia 2007
PANEL. SCHEDULE A IQKAIG
NOTES:
DESCRIPTION
ITEM
NO.
O
W
TRIP
AMPS
TOTAL
WATTS
A 8 G
TOTAL
WATTS
TRIP
AMP..
O
EL
DESCRIPTION
ITEM
NO_
NOTES:
SOFT DRINK DISPENSER
19A
1
20
600
1
3
5
1
9
11
13
15
11
19
21
23
25
27
29
31
33
35
31
39
41
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
SPACE
•
L
CA51 -4 REGISTER
10
1
20
250
660
20
1
MEAT SLICER
28
•
•
DRINK CARBONATOR
30
1
20
1500
1440
20
1
PASS THROUGH REFRIGERATOR
15
L
COLD PAN
14
1
20
600
1200
20
1
COOLER/LIGHTSMEATER
•
VEGETA13LE CUTTER
21
1
20
480
1200
20
1
EVAPORATOR FANS
17/18
L
•
•
MEAT MIXER
29
1
20
1632
1800
20
1
FREEZER CONDENSER
11
L
L
ANSUL /WOOD LIGHTS
e a
913
1
20
1200
1800
20
1
COOLER CONDENSER
18
L
•
RICE WARMER
SA
1
20
1000
455
20
1
LIGHTS
•
•
HOT FOOD
WELL
65
2
30
1500
SPACE
w
,
I
v
1500
1420
20
1
LIGHTS
•
L
ICE MACHINE
208
1
20
1000
1200
20
1
51GN
•
•
MANAGER STATION
54
1
20
250
SPACE
SPACE
SPACE
•
0
REFRIGERATED SASE
11A
1
20
1200
120
20
I
RECEPTACLE
•
•
SPARE
I
20
SPACE
SPARE
1
20
SPACE
•
SPARE
1
20
510
20
1
LIGHTS
•
•
SPARE
1
20
SPACE
SPARE
1
20
SPACE
•
SPACE
SPACE
•
•
SPACE
SPACE
TOTAL
TOTAL
TOTAL
TOTAL
TR4N5FORMER
'A' 8320
AMPS)
08 —
MAIN 100 AMP MAIN CIRCUIT BREAKER
'5' 5°15
VOLTS 120/208V 3 PHASE
ITEM NUMBER
DEVICES
'C' 8122
DENOTES KITCHEN EQUIPMENT
DENOTES CIRCUITS WITH LOCK -ON
SEE LOAD ANALYSIS BELOW
LOAD ANALYSIS
0
—
LIGHTING /SIGNAGE AT 125 % = 3.98 KVA
THERMOSTATICALLY CONTROLLED
KITCHEN EQUIPMENT AT 65% = 1.10 KVA
MISC. EQUIPMENT AT 100% 8.49 KVA
TOTAL LOAD= 22.11 KVA (62
MU411
EF1
1
480V, 3P/30 AMP NEMA 3R
NON FUSED DISCONNECT AT
ROOF MOUNTED EXHAUST
FAN EF -1 AND EF -2 _
4830V, 3F'/30 AMP NEMA 3R
NON FUSED DISCONNECT AT
ROOF MOUNTED HVAC UNIT
RTU -1.
EP2
J
RTU
J
'(3) 010 CU TI-4WN
(1) *12 CU GROUND
(1) 3/4' CONDUIT
REVIEWED FOR
CODE COMPLIANCE
NFPA70dNEC
Mkt 21 2000
LANDLORD PROVIDED 480v
,3P 200 AMP FUSED SERVICE
DISCONNECT N TENANTS
SPACE FUSED AT 200 AMPS_
(1)* 4 CU GROUND TO
BUILDING GROUNDING
SYSTEM .VERIFY
REQUIREMENT_
PANEL "1•-1
3P/4S
(3) % CU THWN
(1) % CU GROUND
(1) 1' CONDUIT
Oty Of Tukwila
ILDDNG D I, N
1--1000
CONTROL
PANEL
TIMECLOCK
NEW 211/450V , 3 PHASE
PANEL 1-I' WITH 200 AMP
MAIN LUGS ONLY. SEE
PANEL SCHEDULE FOR
ADDITIONAL INFORMATION.
01
c
s
'VI0
30 KVA XEMR
PANEL °A°
NO SCALE
NEW 120/208v , 3 PHASE PANEL 'A°
WITH 100 AMP MAIN CIRCUIT BREAKER
SEE PANEL SCHEDULE FOR
ADDITIONAL INFORMATIOiL
PROVIDE (4) *1 CU THWN AND
(1)* 6 CU GROUND IN 1 -1/2'
CONDUIT_
(1) * 6 CU GROUND TO
BUILDING GROUNDING
SYSTEM _VERIFY
REQUIREMENT.
LOB os&
rLEC RIC4L
DE-T-4 LS AND
PANLL S k=
RECEIVE
FEB 2 8 2008
PERMIT CENT&
PRELIMINARY DWGS. FOR L L. APPROVAL
0
TI-
N
0
LL COMMENTS
0
0
0
0
CITY COMMENTS
co
0
0
0
CITY COMMENTS
co
0
CV
N
0
m
w
a
0
<1.<1 <1<zr<g
CONTRACTOR SHALL VERIFY ALL
DIMENSIONS AT THE JOB SITE AND
NOTIFY THE ARCHITECTS OF ANY
DIMENSIONAL ERRORS, OMISSIONS
OR DISCREPANCIES BEFORE
BEGINNING OR FABRICATING ANY
WORK
DO NOT SCALE DRAWINGS
EIt IL: sjdesign�sarkujapan.cam
L
z
w
0
0
(1)
J
W
Li
U)
CO
›- CO
CO
N
a I
CO
CC 00
Z
�7w
Q
0
Q rr)
O ro
cnco 1—
JOB NUMBER
7.21
i
SHEET NUMBER
DATE OF ORIGINAL ISSUE
24 SEFTM35Eia 2007