Loading...
HomeMy WebLinkAboutPermit EL08-0056 - WESTFIELD SOUTHCENTER MALL - SARKU JAPANSARKU JAPAN 2600 SOUTHCENTER MALL FC -3 ELO8-056 Parcel No.: Address: Suite No: CitAof Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 6364200010 2600 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: EL08 -056 03/25/2008 09/21/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: SARKU JAPAN 2600 SOUTHCENTER MALL FC -3 , TUKWILA WA WEA SOUTHCENTER LLC 11601 WILSHIRE BLVD , LOS ANGELES CA TIM PETTIFER Address: 7650 BIRCHMOUNT RD , MARKHAM, ONTARIO, CANADA Contractor: Name: D F ELECTRIC INC Address: PO BOX 7205 , TACOMA WA Contractor License No: DFELEI *010D9 Phone: Phone: 416- 891 -3327 Phone: 253 572 -3704 Expiration Date: 03/31/2009 DESCRIPTION OF WORK: ELECTRICAL SYSTEMS FOR LIGHTING AND RECEPTACLES Value of Electrical: $30,000.00 Fees Collected: $717.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: 074 I hereby certify that I have read and ex ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • h, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo . ance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: 4,0//r„, y Date: 3r2 s-�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -056 Printed: 03 -25 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Permit Number: EL08 -056 Address: 2600 SOUTHCENTER MALL TURIN Status: ISSUED Suite No: Applied Date: 01/16/2008 Tenant: SARKU JAPAN Issue Date: 03/25/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: •, dZw �e�,7'�e�j Date: 3 ' Z J — e� doc: Cond -Elec EL08 -056 Printed: 03 -25 -2008 CITY OF TUKWIL• Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us • Electrical Permit No. - LC os rosoE Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not he accepted through the mail or by fax. * *Please Print ** SITE LOCATION �� *� �pp I. King Co a Assessor's Tax No.: (L ? 1 1-( )-U " w 1 G� Site Address: (..0-S Cel er- Tkw9 Tuk►ka, �(X 9s1iS$" 2ii S5 Suite Number: re.- S Floor: 2 Tenant Name: cRik InOviiv.e.riier Food Itic. DF3P SOrktA £n New Tenant: fSI Yes ❑ ..No Property Owners Name: W F Pr cD q c.eriter . L LC t- r � Mailing Address: 1 [ (o01 1 1 s �, (',----e_, Bl.vo1 1 I'A, FJr)ar A c g, , ,,Je ) Oa 9br) 25 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: j r ►'�'{ ']�,/ 1) Mailing Address: }%650 B 'rdl✓vtdwtf Rd E -Mail Address: +p 4 t f d 30-' kt poi- . c M Day Telephone: H 1 (,,D - 8°11 via ek.t- City t `lt>f`; o Co4oe4 l 3 R State Zip Fax Number: e(05, 7/4 -042 -1 ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: State Zip Valuation of Project (contractor's bid price): $ Spi 000 Scope of Work (please provide detailed information): Ca I S j Wt5 . �l �( kb' �t-�j / 5 t.iit by ve IQ.� `T'a L�S �J U V ( Q Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Re_ Sfstlit.� r c $ Type of work: New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator [a. Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H tApphcahor l orms- Applications On Line \4-2007 - Electrical Permit Application doe hh Page 1 of 2 1 '4 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ Ncw single family dwellings $140.00 (including an attached garage) ❑ Garages. pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm. furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ca ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm. furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOI'S FEES ❑ Temporary service (residential) $58 -00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing and justifiable cause demonstrated. I IIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASI IINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BURTIM CT OWN .' OR ELE 'I'RICAL TRACTOR: Signature: Print Name: Mailing Address: Fe) "PO) e ) 21 Date: 4 CU- (CIr-- Day Telephone: t 6 '3 `R $ 1 - 1 sO q- CAYeroA.Lvr-I" 0 {R-- 1-1 o l City State Lip Date Application Accepted: 1-(to-08" - l l!/ % 8" Date Application Expires: Staff Initials: i , ,re. H `.4pplicanons•J orms- Apphcanons On Line•4 -2007 - Electncal Permit Application doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -056 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/16/2008 Applicant: SARKU JAPAN Issue Date: Receipt No.: R08 -00889 Payment Amount: $574.00 Initials: JEM Payment Date: 03/25/2008 10:54 AM User ID: 1165 Balance: $0.00 Payee: D. F. ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24095 574.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 574.00 Total: $574.00 1 • doc: Receiot -06 Printed: 03 -25 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -056 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/16/2008 Applicant: SARKU JAPAN Issue Date: Receipt No.: R08 -00138 Payment Amount: $143.50 Initials: WER Payment Date: 01/16/2008 03:13 PM User ID: 1655 Balance: $574.00 Payee: WOODBURN CONSTRUCTION TRANSACTION LIST: Type Method Description Amount Payment Check 2635 143.50 ACCOUNT ITEM LIST: Descript ion Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 143.50 Total: $143.50 7321 01/16 9710 TOTAL 1862.13 doc: Receipt -06 Printed: 01 -16 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: A ✓ t Type of Inspection: 0,00 Address: 2100 ter{/ Date Called: Special Instructions: Date Wanted: 7/1‘ p`. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: • Inspector: 2-1-16674vtic Date: Ol j�� �� ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be k paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ecog_o$ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 5 4400 f3 Type of Inspection: `040 Address: 2-G 00 ti � Date Called: Special Instructions: Date Wanted: /01 La)..7.1.. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: IA of TO CDLp - 1.- 1 1M ( ato- F&. DtF24°" /a L.TC s'45 5 - CAtEcr ul . -14 muck Inspector: 6tdwec- Date: O,P oqk El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit ELcc -USA PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 (4 Proje'a a"�q,�I,v Type of Inspection: -206 7 Address: Date Called: Strii/Lfw1 /P At Special Instructions: Date Wanted: /� P- Requester: Phone No: pproved per applicable codes. D Corrections required prior to approval. OMMENTS: fit? 014 - C /6 1,1/4, -- 7lr�1.- T4- Inspect `ti /I i V f 11(6 `I Date / / El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: L� INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project: /4 19 % X00/2. f / .CT2(/g 77, ,((/ h/t/G Type of Inspection: Type 1) T' f (/L t Ix / ,s7//4,/b4;--4.0 pip/ :. 2- 9 iin7 47 /o' - D°Ac /AI 6 Address: Za9 jeer/felt/7W Aeate Called: i4)7i' IN' 6- Af/ (/- F /..[% 1`- 77rn /o,) 6 01)6- fa� ar,ex C Special Instructions: Date Wanted: t a.m. p.m. Requester: Phone No: ElApproved per applicable codes. orrections required prior to approval. COMMENTS: X00/2. f / .CT2(/g 77, ,((/ h/t/G .x`111 *_,-r-4/1 1) T' f (/L t Ix / ,s7//4,/b4;--4.0 pip/ :. 2- 9 iin7 47 /o' - D°Ac /AI 6 F i l ' . ,Cier Ili L - - O NE7 T /a4J C M / kill 14)4 w_ 0 cigt /)77/ I41b-S f)f c-a OW 7---r i4)7i' IN' 6- Af/ (/- F /..[% 1`- 77rn /o,) 6 01)6- fa� ar,ex C c Inspect 07-k 0) l6 Dater /o !6 r $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Project :�� T�n V! Type of Inspection: ��j 7 1V �I DP2o1V'Ae- Sf I Cm ic Ais /GA) ,444 Address: .(4/-41.0.-v AI- Date Called: pecial Date Wanted: y /215 / 7P.m. a.m. Requester: Phone No: Approved per applicable codes. orrections required prior to approval. COMMENTS: DP2o1V'Ae- Sf I Cm ic Ais /GA) ,444 fit/GM/AN (, icolt sI S/aEi/ 44.N 7741 nSFOfV77 )SM t.- oTh ,c NA. 2f Cr r/4 u! 73 Pillii,W 6- 6-00L.6-45 / 1/ 4--42J Inspep G �„ mow" n w" Date: 19/z870f El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit toF -03"6" CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 \i‘ PERMIT NO. (206)431 -3670 Pr ect: 5Y2K i ,ill /9•v Type of Inspection: —203 Add reess: �favU 0/,,•91C E./ L Date Called: Special Instructions: Date Wanted: `4• / a.m. p.m. Requester: Phone No: roved per applicable codes. ❑ Corrections required prior to approval. C • MENT5M 0/Z. - ( /t i4 - Arr 4i Inspecto Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit kzos-osd PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 9 81 88 (206)431 -3670 Project: 5,q/2.Kl/ i/3) Type of Inspection: ,.., 7003 v S00,T c( 7 ? 944v Ail. Date Called: Special Instructions: Date Wanted: ]� (/6 Requester: Phone No: W2proved per applicable codes. COMMENTS: log ❑ Corrections required prior to approval. Old - wP,�� C_-()Vi/<\ Insp #1- re-roAAA/chi Date.-y/.7 /U $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: Marc Brundige February 27, 2008 City Of Tukwila Attn: Building Division 6300 Southcenter Blvd., #100 Tukwila, WA 98188 Phone: 206.431.3670 Permit Number: EL08 -056 Project Name: Sarku Japan Address: 2600 Southcenter Mall, Suite FC -3 Plan Reviewer: Bill Buterbaugh, PH: 206.973.4758 Please find attached 3 complete sets that include the revisions per building department comments noted below. The following notes describe our response to each item. Mechanical Comments: 1) Make -up air unit and exhaust fans 1 & 2 are not included in the panel schedule or Toad calculation for Panel H1. Provide new panel schedule and Toad calculation. Please see sheets E1.0 & E2.0, revisions have been made and clouded. 2) Provide an average of 1 footcandle illumination at the floor along the entire egress pathway and exit discharge. The landlord is responsible for lighting this area and will provide separate documents. Thank you for your time and attention to this project. Please feel free to contact me with any concerns. Sincerely, Marc Brundige Marc Brundige 5005 W. Royal Lane, Suite 144 Irving, Texas 75063 Voice: 972.929.9226 Fax: 972.929.9061 www.linear-architecture.com REGISTERED ARCHITECT STAT MARC F SRUNDIGE WASHINGTON FILE COPY CORRECTION LTR ILA- EioB-OSb RECEIVED FEB 2 8 2008 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary 2006 Washington State Nonresidential Energy Code Compliance Forms PRJ -SUM Revised July 2007 Project Info Project Address sarku Japan Date 1/3/2008 633 South Center Pkwy For Building Department Use Tukwila,Wa 98188 Applicant Name: q - Fill out this line on PRJ -SUM Applicant Address: s - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM rl ` Si( eit RLE CIPY ELo@ 0510 .F JAN 17 2008 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Sarku Japan Date 1/3/2008 633 South Center Pkwy For Building Department Use Tukwila,Wa 98188 Applicant Name: 4 - Fill out this line on PRJ -SUM Applicant Address: 5 - Fill out this line on PRJ -SUM Applicant Phone: 6 - Fill out this line on PRJ -SUM Project Description ❑ New Building ❑ Addition [ J Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive ® Lighting Power Allowance ❑ Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 ** Area in ft2 Allowed x Area All Restaurant /fast food 1.30 819.0 1064.7 Front Fluorescent strip light under counter 11 20.0 220.0 Front CF down light w/ (1) 26W DTT 17 21.0 357.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1064.7 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Kitchen 2x4 2 lamp fluorescent with (2) 32W 18 electronic ball 7 65.0 455.0 Front Fluorescent strip light under counter 11 20.0 220.0 Front CF down light w/ (1) 26W DTT 17 21.0 357.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1032.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: (� Warehouses, storage areas or aircraft storage hangers °Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) u Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPAz (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail'°, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia°, assembly spaces° 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall'•° 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form E xterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Proj Addres sarku Japan Date 1/3/2008 633 South Center Pkwy For Building Department Use Tukwila,Wa 98188 Name: 4 - Fill out this line on PRJ -SUM Appl. Name s - Fill out this line on PRJ -SUM Appl. Phone 6 - Fill out this line on PRJ -SUM Project Description ❑New ❑ Addition Li Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) motion Sensor ❑ Efficacy > 60 lumens/VV • Controlled by ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting fl Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Tradable Proposed Lighting Wattage Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -w'red ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts Non - Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (10 or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Proposed Watts may not exceed Allowed Watts for Category 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft2 Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater Plaza areas Special feature areas 0.2W /ft2 Stairways 1.0 W/ft2 Building Entrances and Exits Main entries 30 W /linear foot of door width Other doors 20 W /linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W /ft2 Street frontage for vehicle sales lots in addition to "open area" allowance 20 W /linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 W /ft2 for each illuminated wall or surface or 5.0W /linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/112 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W /112 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Material handling and associated storage 0.5 W /ft2 Drive -up windows at fast food restaurants 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -LPA Revised July 2007 Project Address Sarku Japan Date 1/3/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2" Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 " From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Sarku Japan IDate 1/3/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controVaccess Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch n. a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n. a. (a) timer w/backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n. a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability) Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 IMax. watts 'Indicate watts for each exit sign I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'Indicate size and efficiency I I If "no" is circled for any question, provide explanation: 4 ,Lighting 2006 Washin. ton State Nonresidential Energ Code Com'Hance Form Motor, and Transformer Permit Plans Checklists l 2006 Washington State Nonresidential Energy Code Compliance Forms CI Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling - height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting_ 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk- to-dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director February 13, 2008 Tim Pettifer 7650 Birchmount Rd Markham Ontario, Canada L3R6B9 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL08 -056 Sarku Japan — 2600 Southcenter Mall, Suite FC -3 Dear Mr. Pettifer, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted throuMh the mail or by a messenger service. if you have any questions, please contact me at (206) 433 -7165. Sincerely, 4510,4 Brenda Holt Permit Coordinator encl xc: File No. EL08 -056 P:\Permit Center\Correction Letters\2008\ELO8 -056 Correction Ltr NI.DOC ion 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 • • Building Division Review Memo Date: February 13, 2008 Project Name: Sarku Japan Permit #: EL08 -056 Plan Reviewer: Bill Buterbaugh 1. Make -up Air unit and exhaust fans 1 & 2 are not included in the panel schedule or load calculation for Panel H1. Provide new panel schedule and load calculation. 2. Provide an average of 1 footcandle illumination at the floor along the entire egress pathway and exit discharge. •PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -056 DATE: 02 -28 -08 PROJECT NAME: SARKU JAPAN SITE ADDRESS: 2600 SOUTHCENTER MALL FC -3 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Bui ding !vision Fire Prevention Planning Division Public Works n Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03 -04 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -01-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -056 DATE: 01 -17 -08 PROJECT NAME: SARKU JAPAN SITE ADDRESS: 2600 SOUTHCENTER MALL FC -3 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: , �3.D BARN DiVi'sion Public Works 111 Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 01 -22 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROkiTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02 -1 9-08 Not Approved (attach comments) 1-4. DATE: Permit Center Use Only �j CORRECTION LETTER MAILED: ` �� Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: /y/ Documents/routing slip.doc 2 -28 -02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: � Z'Oo Plan Check/Permit Number: ❑ Response to Incomplete Letter # El Response to Correction Letter # t ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: 33( s d<A L -� Contact Person: "--1 Phone Number: 41 (3 ' 3 327- Summary of Revision: t■A lr\ Ar ►+ ;2.:EIVED CIS OF TUKMI.A 1±b 28 2008 Sheet Number(s): "Cloud" or highlight all areas of revision including d e of revisio Received at the City of Tukwila Permit Center by: Entered in Permits Plus on a : )-k -09 iapplicationslfosms- applications on linerevision submittal nenteit. a_1aanne Look Up a Contractor, Elects an or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License DFELEI *010D9 Licensee Name D F ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601940601 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 PO BOX 7205 Address 2 City TACOMA County PIERCE State WA Zip 98406 Phone 2535723704 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/29/1999 Expiration Date 3/31/2009 Suspend Date Separation Date Parent Company Previous License DFELE * *269DM Next License Associated License BENTLA *972QG Master Electrician Information License BENTLA * 972QG Name BENTLEY, ANDREW Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BENTLEY, ANDREW AGENT 09/16/2003 BENTLEY, ANDREW PRESIDENT 09/16/2003 BENTLEY, LYNETTE M SECRETARY 09/16/2003 • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= DFELEI *010D9 03/25/2008 WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 SPACE# FC -3 EY P LA\ o SARKU JAPAN SPACE# FC -3 LEVEL: 02 OF 3 SO. FT.: 816 PROJECT INFORMATION: OWNER: SARKU JAPAN 7650 BIRCHMOUNT ROAD, MARKHAM, ONTARIO CANADA L3R 6B9 TEL: (905) 474 -0710 FAX: (905) 474 -0421 PROJECT MANAGEMENT: SJ DESIGN BUILD INC. 7650 BIRCHM❑UNT ROAD, MARKHAM, ONTARIO CANADA L3R 6B9 TEL: (905) 415 -5700 FAX: (905) 474 -0421 ATTN.% TIM PETTIFER - DIRECTOR, CONSTRUCTI ❑N ARCHITECT: LINEAR ARCHITECTURE 5005 WEST ROYAL LANE, SUITE 144 IRVING, TX 75063 TEL: (972) 929 -9226 FAX (972) 929 -9061 ATTN.: PHILIP KEMERY / MERCI KEMERY LANDLORD: WESTFIELD CORP❑RATI ❑N 14TH FLOOR 11601 WILSHIRE BLVD. LOS ANGELES, CA 90025 TEL.: (310) 893 -4761 FAX. (310) 575 -5991 ATTN.: JOSH KIMMEL - PROJECT MANAGER MALL PROPERTY MANAGEMENT: WESTFIELD SOUTHCENTER 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 TEL.: (206) 246 -0423 ATTN.: OPERATIONS MANAGER BUILDING DEPARTMENT: CITY OF TUKWILA 6300 SOUTHCENTER BLVD. #100 TUKWILA, WA 98188 TEL,: (206) 431 -3670 FIRE DEPARTMENT: 444 ANDOVER PARK EAST TUKWILA, WA 98188 TEL.: (206) 575-4404 EMAIL: tukfdadri@ci,tukwi ; a.wa,us HEALTH DEPARTMENT: WASHINGT ❑N STATE DEPARTMENT OF HEALTH 101 ISRAEL RD. SE TUMWATER, WA 98501 TEL,; (360) 236 -4501 TENANT: TENANT: SARKU JAPAN ADDRESS: WESTFIELD SOUTHCENTER SPACE# FC3 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 -2888 APPLICABLE CODES CONSTRUCTION TYPE EXISTING CONSTRUCTION TYPE: TYPE II — B — UNPROTECTED NONCOMBUSTIBLE FULLY SPRINKLED OCCUPANCY GROUP PRIMARY OCCUPANCY: M — MERCANTILE APPLICABLE CODES BUILDING — 2006 INTERNATIONAL BUILDING CODE WITH WASHINGTON STATE AMENDMENTS MECHANICAL — 2006 INTERNATIONAL MECHANICAL CODE WITH WASHINGTON STATE AMENDMENTS PLUMBING — 2006 UNIFORM PLUMBING CODE WITH WASHINGTON STATE AMENDMENTS ELECTRICAL — 2005 NATIONAL ELECTRICAL CODE WITH WASHINGTON STATE AMENDMENTS ACCESSIBILITY — CHAPTER 11 IBC AND OTHER INTERNATIONAL BUILDING CODE REQUIREMENTS FOR BARRIER —FREE DESIGN ACCESS INCLUDING ICC/ ANSI A117.1 -- 2003 ENERGY — 2006 WASHINGTON STATE ENERGY CODE FIRE — 2006 INTERNATIONAL FIRE CODE WITH WASHINGTON STATE AMENDMENTS DRAWING INDEX C -1 COVER SHEE I C -2 ROOM FINISH & RESPONSIBILITY SCHED., WALL LENGEND A -1 REFL. CLG. PLAN & FLOOR A -2 ELEVATIONS A -3 ELEVATIONS AD -1 AD -2 AS -1 K -1 K -2 PLAN DETAILS DETAILS ARCHITECTURE SPECIFICATIONS & NOTES EQUIPMENT PLAN, COUNTER CUT —OUT, ELECTRICAL ROUGH —IN PLANS/ LOCATIONS EQUIPMENT SCHEDULE H -1 HOOD DRAWINGS H -2 HOOD DRAWINGS H -3 HOOD DRAWINGS M -1 MECHANICAL PLAN & SCHEDULES E -1 POWER & LIGHTING PLANS E -2 ELECTRICALS DETAILS & PANEL SCHEDULES P -1 PLUMBING PLANS P -2 PLUMBING DETAILS SEPARATE PERMIT REQUIRED dhiecranical t Electrical *Plumbing SIGas Piping City of Tukwila BUILDING DIVISION & PLUMBING REVISIONS NO changes shall be made to the scope of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan yubrn ►I and may include additional plan rco' k FILE COPY Permit No, Mar review approval Is subject to errors and omisskins. Approval of construction doaunerds does not authorize the violatlon of any adopted code or ordnance. �: of approved Fief. By Date: City of Tukwila BUILDING DIVISION APPROVED P! ;ANGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING 07I ^ :AI., ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND I5 '1.13,;aCT TO FIELD INSPECTIONS ABBR T_VIAT1 O \Se A.F.F. ACT. ADJ. A.C. ALT. ALUM. A.B. & APPROX. Q AWN. B.C. B.P. BM. BLK. B.S. B.W. N. BRK. BLDG. CAB. CPT. C.I. C.B. CLG. CEM. CTR. C.T. CHBD. C.O. CLO. COL COM. CONC. CONST. C.M.U. CONT. CONTR. C.J. C.TOP DEMO. DEPART. DTL. DIA. DIM. DR. DTA. DT.S. DN. DWG. D.F. EA. E. ELEC. E.C. E.H.D. E.W.C. ELEV. ENCL. EQ. EQUIP. EXIST, E.J. EXP. EXT. ABOVE FINISH FLOOR ACOUSTICAL ADJUSTABLE AIR CONDITION / CONDIUONED/ CONDITIONER /CONDITIONING ALTERNATE ALUMINUM ANCHOR BOLT AND APPROXIMATELY AT AWNING BASE CABINET BASE PLATE BEAM BLOCK BOTH SIDES BOTH WAYS BOTTOM BRICK BUILDING CABINET CARPET CAST IRON CATCH BASIN CEILING CEMENT CENTER CERAMIC TILE CHALKBOARD CLEAN OUT CLOSET COLUMN COMBINATION CONCRETE CONSTRUCTION CONCRETE MASONRY UNIT CONTINUOUS CONTRACTOR CONTROL JOINT COUNTER TOP DEMOLITION DEPARTMENT DETAIL DIAMETER DIMENSION DOOR DOVETAIL ANCHOR DOVETAIL SLOT DOWN DRAWING DRINKING FOUNTAIN EACH EAST ELECTRICAL ELECTRICAL CONTRACTOR ELECTRIC HAND DRYER ELECTRIC WATER COOLER ELEVATION ENCLOSURE EQUAL EQUIPMENT EXISTING EXPANSION JOINT EXPOSED EXTERIOR E.G.C.B. EXTERIOR GYPSUM CRAG BOARD F.O.S. FT. F.N.D. F.N.V. FIN. FIN. OPNG. F.E. F.E.C.R. F.H. F.R.P. F.R.T. FL F.D. F.P. FTG. F.M. GALV. GA. G.C. GL G.B. G.W.B. GYP. HC. HDW. HT. H. H.C. H.M. HORIZ. IN. INCL I.D. INSUL. JT. JST. LAM. LL LAV. L. MGR. M.H. MFR. MAS. M.O. MAT'L. MAX. MECH. MT. M.F. M.S. M.R.D. MIN. M. MISC. M.R. M.B.H. MTD. N. N.I.C. N.T.S. NO. FACE OF STUD FEET FEMININE NAPKIN DISPOSAL FEMININE NAPKIN VENDOR FINISH FINISH OPENING FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET RECESSED FIRE HYDRANT FIRE RETARDANT PANEL FIRE RETARDANT TREATED FLOOR FLOOR DRAIN FLUSH PANEL FOOTING FRAMED MIRROR GALVANIZED GAUGE GENERAL CONTRACTOR GLASS GRAB BAR GYPSUM WALLBOARD GYPSUM HANDICAPPED HARDWARE HEIGHT HIGH HOLLOW CORE HOLLOW METAL HORIZONTAL INCH INCLUDE INSIDE DIAMETER INSULATION JOINT JOIST LAMINATED LANDLORD LAVATORY LONG MANAGER MANHOLE MANUFACTURER MASONRY MASONRY OPENING MATERIAL MAXIMUM MECHANICAL METAL METAL FRAME METAL STUD METAL ROOF DECK MINIMUM MIRROR MISCELLANEOUS MOISTURE RESISTANT MOP AND BROOM HOLDER MOUNTED NORTH NOT IN CONTRACT NOT TO SCALE NUMBER 0.C. OPNG. OPP. HAND 0.D. PR. P.T.D. P.T.H. P.COL PLAS. P. LAM. PLUMB. P.C. PLYWD. P.T. PHONE Q.T. R. RECT. REINF. REQ'D. REV. R.D. RM. R.O. S.C.O.F. S.N.D. SCH. SNT. SECT. SHT. SHO. SHO.C. SHO.H. SIM. S.D. S.H. S.C. S. SPECS. SQ. SQ.FT. S.S. STD. STL STR. S.M.S. SUSP. SYS. TKBD. T.C. T.P.H. T.& G. T.B. TYP. U. U / S V.T.R. VERT. V.T. W.R. W.C. W.H. W.P. W. W/. W /0. WD. ON CENTER OPENING OPPOSITE HAND OUTSIDE DIAMETER PAIR PAPER TOWEL DISPENSER PAPER TOWEL HOLDER PIPE COLUMN PLASTER PLASTIC LAMINATE PLUMBING PLUMBING CONTRACTOR PLYWOOD PRESSURE TREATED TELEPHONE QUARRY TILE RADIUS RECTANGULAR REINFORCEMENT REQUIRED REVISION ROOF DRAIN ROOM ROUGH OPENING SLIP COEFFICIENT OF FRICTION SANITARY NAPKIN DISPOSAL SCHEDULE SEALANT SECTION SHEET SHOWER SHOWER CONTROLS SHOWER HEAD SIMILAR SOAP DISPENSER SOAP HOLDER 50LID CORE SOUTH SPECIFICATIONS SQUARE SQUARE FEET STAINLESS STEEL STANDARD STEEL STRUCTURAL STRUCTURAL METAL STUD SUSPEND SYSTEM TACKBOARD TENANT C0- ORDINATOR TOILET PAPER HOLDER TONGUE AND GROOVE TOWEL BAR TYPICAL UNLESS OTHERWISE NOTED URINAL UNDERSIDE VENT THROUGH ROOF VERTICAL VINYL TILE WASTE RECEPTACLE WATER CLOSET WATER HEATER WATER PROOF WEST WIDTH WITH WITHOUT WOOD (SY v BOSS LEG SECTION CUT INDICATI ❑N PLAN DETAIL INDICATION ELEVATION INDICATION DOOR IDENTIFICATION FINISH INDICAT ❑R EQUIPMENT SYMBOL FURNISHING & ACCESSORIES INDICATOR GENERAL NOTES ELEVATION TARGET SECTION NUMBER SHEET NUMBER DETAIL AREA DETAIL NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER NOTES WHICH APPLY TO SPECIFIC ITEMS ON DRAWINGS WHERE INDICATED. 3). NOTES WHICH APPLY TO ALL DRAWINGS. 0, -0' — ELEVATI ❑N ABOVE FIN. FLR71"---- SURFACE DESCRIPTI ❑N L.L. CENTERLINE DIAMETER PLATE LEASE LINE Public Works, Building Division PERMIT NUMBER JAN 16 2008 COVER SHEET ELO&' 056 PRELIMINARY DWGS. FOR L.L. APPROVAL LL COMMENTS m N 0 2 w Q '<.<1<<<2 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK DO NOT SCALE DRAWINGS U U rcs E 0 0 1- 0 mam z� =Oct 0 n mzo o r- M V O N i LO 0 0 0 0 0 0. 0 0 w w CO ''%_. SINi CC z ACV Li_l C._.) I CO CO Li j O M, w °' 0 L`H- w a: GO c0 JOB NUMBER 21 SHEET NUMBER c1 FILE COPY DATE OF ORIGINAL ISSUE 24 SEPTh18E 2 2+Dc2)7 STATISTICS DESCRIPTION SYMBOL AVG MAX/MIN A VG/M IN CALC ZONE 41 13.0:1 6.8:1 CIRCUIT EMERGENCY/EXIT LIGHTING ON UNSWITCHED LEG OF LOCAL LIGHT CIRCUIT_ 1.7 +1.7 +1.5 +1.3 +1.1 +0.9 2.5 2_� i i 2.1 1/ 1/ \I E" ___A + + + + + + + 2.0 2.3 _ 2.6 2.6 2.5 2.3 2.0 1.8 + + + 1.0 0.8 0.7 + + + 1.2 1.0 0.9 + + + + + + + + + + 1.4 1.8 2.1 2.4 2.5 2.5 2.4 2.3 2.2 1.9 SEE SASE BUILDING DRAWINGS FOR EGRESS LIGHTING OUTSIDE OF THIS TENANTS SPACE_ OTE S 5' SYM OL PROVIDE JUNCTION BOX WITH ASSOCIATED 120V ,r/20 AMP CIRCUIT FOR MENU SOX AND PICTURE BOARD LIGHT BOXES. SEE ARCHITECTURAL DETAILS FOR EXACT MOUNTING REQUIREMENTS. SEE LIGHT FIXTURE SCHEDULE TYPES "C' AND "D" FIXTURE. 120V ,1P/30 AMP NON FUSED NEMA 3R DISCONNECT ON ROOF FOR REMOTE FREEZER AND COOLER CONDENSING UNITS. VERIFY LOCATION. 120V ,1P/30 AMP NEMA 3R DISCONNECT AT FREEZER AND COOLER EVAPORATOR BLOWERS JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR FREEZER/COOLER LIGHTS AND DOOR HEATER_ VERIFY LOCATION AND CONNECTION REQUIREMENTS. `: I 480V 3P/20 AMP DISCONNECT ON ROOF AT EF -1 AND EF -2. SEE EXHAUST PAN SCHEDULE FOR AND CONTROL BOX WIRING DIAGRAM ON DRAWING SHEET H2 ADDITIONAL INFORMATION. n 4S0V ,3P/20 AMP DISCONNECT ON ROOF AT MUA -1. SEE EXHAUST FAN SCHEDULE �/ FOR AND CONTROL BOX WIRING DIAGRAM ON DRAWING SHEET 142 ADDITIONAL INFORMATION_ PROVIDE JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR ANSUL SYSTEM CONNECTION. CONTRACTOR MUST VERIFY INTERLOCK REQUIREMENTS FOR AN5UL AND EXHAUST SYSTEMS. p PROVIDE JUNCTION BOX AND ASSOCIATED 120v ,1P/20 AMP CIRCUIT FOR HOOD LIGHTS. VERIFY MOUNTING REQUIREMENTS_ n 30 KVA TRANSFORMER SUSPENDED FROM STRUCTURE ABOVE_ SEE ELECTRICAL �J SERVICE RISER FOR ADDITIONAL INFORMATION_ VERIFY LOCATION AND MOUNTING REQUIREMENTS_ 11,-;31 450V ,3P/20 AMP DISCONNECT AND ASSOCIATED CIRCUIT FOR WATER HEATER CONNECTION_ VERIFY MOUNTING HEIGHT_ 11 ELECTRICAL PANELS "A" AND '14' . SEE ELECTRICAL SERVICE RISER AND PANEL SCHEDULE FOR ADDITIONAL INFORMATION. 12 PROVIDE JUNCTION BOX AND ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR SIGNAGE_ VERIFY LOCATION . CIRCUIT THROUGH TIME CLOCK 13 120V ,1P/20 AMP GFI RECEPTACLE IN WP ENCLOSURE FOR HVAC MAINTANENCE. + + + + + + + + + ,0.8 1.0 1.1 1.3 1.6 1.9 2.2 2.4 CIRCUIT EMERGENCY/EXIT LIGHTING ON UNSWITCHED LEG OF LOCAL LIGHT CIRCUIT_ NUMBER INDICATES - FOOT CANDLE LEVEL AT FLOOR (TYPICAL) 0 4 +0.6 +0.7 +0.9 +1.1 1.4 1.5 1.4 1.2 1.1 1.0 'EM' +1.0 +1.2 1.3 * +0. +0.8 PRELIMINARY DWGS. FOR L.L. APPROVAL m LL COMMENTS CITY COMMENTS CITY COMMENTS REVISIONS N cn O CO d Cr) co 0 O CO O CV N O <KK<T'<12 CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK DO NOT SCALE DRAWINGS 14 480v 3P/30 AMP NEMA 3R NON FUSED DISCONNECT ON ROOF AT RTU. VERIFY LOCATION. SEE ELECTRICAL RISER DIAGRAM FOR ADDITIONAL INFORMATION. 15 PROVIDE JUNCTION BOX FOR CONNECTION OF TYPE 'A" TRAY RAIL LICxHTINCx. SEE ARCHITECTURAL DETAILS FOR EXACT LOCATION. 16 PROVIDE JUNCTION BOX WITH ASSOCIATED 120V ,1P/20 AMP CIRCUIT FOR JAPANESE SCREEN LIGHTING SEE ARCHITECTURAL DETAILS FOR EXACT MOUNTING REQUIREMENTS. JUNCTION BOX AND 480V 3P/20 AMP CIRCUIT FOR EXHAUST FAN CONTROL PANEL. SEE WIRING DIAGRAM ON DRAWING SHEET 142. EGRESS LIG�ITINC FLAN SCALE: 1/4' = 1'.0' TRAY RAIL LIGHTING -I SEE DETAIL I /AD1 AND 2/4D1 FOR EXACT LOCATION 02 LIG - 4TINCB FLAN PNL "A" FNL "H" SERVICE DISCONNECT AS 410 IS I 414 45 14 14,16,18 413 r I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 42 142,4,6 �` N. E1-9-1 \ \ N. 120V CONTROL CIRCUIT FROM CONTACTS AT CAPTIVE AIR HOOD / ANSUL CONTROL PANEL. SEE EXHAUST SYSTEM DETAIL DRAWINGS HI AND H2 FOR ADDITIONAL INFO1�1 1ATION. 1-11 • j 1-13 • J H5 • J 141 • .� I-19 • 1-111 • 120V_ R� COIL f2OV 60 AMP 6 POLE ELECTRICALLY HELD CONTACTOR W/ 120V COIL. ALL CONTACTS TO BE NORMALLY CLOSED. GRIDDLE 1 GRIDDLE 2 LIGHT � f X T l SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS 'A' 2X4 TROFFER WITH ACRYLIC LENS RECESSED 2 -P32T8 METALUX *2G- 232419- 120v. -EB81 4 ►.- IT_� 14 #2GT - -1/4- ' AE' 2X4 TROFFER WITH ACRYLIC LENS AND EMERGENCr RECESSED 2 -F32TS BATTERY PACK. METALUX *2G- 232A1g- 120V- EM -ES2 (ALTERNATE: LITHONIA "2GT- 232419 -1/4- 120 -GEB) 6" 4 URE REG�ED�DOWN� (1� � RECESSED 26W DTT DTT. 120v. PROVIDE WITH LOW IRON SAFTEY GLASS e LENSES_ 1� /��� J ���� 'C' ME LIGHT _ 120V . SURFACE (6)F20 RSTP CUSTOM MODE FIXTURE COORDINATE WITH ARCHITECTURAL DRAWINGS FOR NUMBER OF BOXES TO BE INSTALLED. ' D' PICTURE BOARD LIGHT 120v SURFACE (6�F20 RSTP CUSTOM MADE FIXTURE COORDINATE WITH ARC1- IITECTURAL DRAWINGS FOR NUMBER OF BOXES TO BE INSTALLED_ 'E' SLENDER LIGHT SL24F RECESSED 20W COMPACT FLUORESCENT WITH BUILT IN ELECTRONIC BALLAST. FIXTURE USES * SL24 -CW -BULB COOL WHITE 20 WATT LAMPS 'X' LITHON14, LHQMSWIRN LED EXIT SIGN/EMERGENCY, SURFACE INCLUD�1� COMBO UNIT. WITH BATTERY BACK -UP_ rr 'EM' LITHONI4, ELM2, WALL MOUNTED, DUAL HEADS. SURFACE INCLUDED EMERCaENCY LIGHT W /90 MINUTE BATTERIES. 4_4 .2c2-* V.� tp.o c r U Q E 0 Lr) LID t -d N m N • L.0 C4 r w L ro �` Q1 6-; rtd • `xx n rn c LC obc� x . o E 0 a C CONTACTOR LC -1 60 AMP 6 POLE ELECTRICALLY HELD > CONTACTOR W/ 120v COIL. ALL CONTACTS TO BE NORMALLY CLOSED. 0 0 1- 0 zto x0 CC CC 0 moo Lc) ¢Q EMAIL: sJdesign ®sarkujapon.cam NOTE: KITCHEN FIRE SUPRESSION SYSTEM MUST BE CONNECTED TO LANDLORDS MAIN FIRE ALARM BY LANDLORDS APPROVED FIRE ALARM CONTRACTOR AT TENANTS EXPENSE. LANDLORDS EQUIPMENT ENCLOSURE---- - 14,I6,1S H13 --• 1415 Hl-1 415 425 48 �-- GRIDDLE 3 NOTE: FRONT SERVERY LIGHTS AND MAIN SIGN MUST SE CIRCUITED THROUGH TIME CLOCK SET TO LANDLORDS SCHEDULE. RICE WARMER * SA REFRIGERATED BASE *11,4 1-100D LIGHTS w W U 0 (f) a w (1) w H- 14,16,18 CONTACTOR LC -2 JOB NUMBER J.21 O3 ELECTRICAL AUTO SHUTDOUJN CONTACTOR DETAIL H- 20,22 ,24 SCALE: 1/4' = l' =0' NO SCALE CORRECTION QTR# ELO 9'O5& SHEET NUMBER RECEIVED FEB 2 8 2008 PERMIT CENTER PL,l6vR AND PLANS 1 FILE tWY DATE OF ORIGINAL ISSUE 24 SEPTMSER 2007 _ _ _.-/ LIGHT � f X T l SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS 'A' 2X4 TROFFER WITH ACRYLIC LENS RECESSED 2 -P32T8 METALUX *2G- 232419- 120v. -EB81 4 ►.- IT_� 14 #2GT - -1/4- ' AE' 2X4 TROFFER WITH ACRYLIC LENS AND EMERGENCr RECESSED 2 -F32TS BATTERY PACK. METALUX *2G- 232A1g- 120V- EM -ES2 (ALTERNATE: LITHONIA "2GT- 232419 -1/4- 120 -GEB) 6" 4 URE REG�ED�DOWN� (1� � RECESSED 26W DTT DTT. 120v. PROVIDE WITH LOW IRON SAFTEY GLASS e LENSES_ 1� /��� J ���� 'C' ME LIGHT _ 120V . SURFACE (6)F20 RSTP CUSTOM MODE FIXTURE COORDINATE WITH ARCHITECTURAL DRAWINGS FOR NUMBER OF BOXES TO BE INSTALLED. ' D' PICTURE BOARD LIGHT 120v SURFACE (6�F20 RSTP CUSTOM MADE FIXTURE COORDINATE WITH ARC1- IITECTURAL DRAWINGS FOR NUMBER OF BOXES TO BE INSTALLED_ 'E' SLENDER LIGHT SL24F RECESSED 20W COMPACT FLUORESCENT WITH BUILT IN ELECTRONIC BALLAST. FIXTURE USES * SL24 -CW -BULB COOL WHITE 20 WATT LAMPS 'X' LITHON14, LHQMSWIRN LED EXIT SIGN/EMERGENCY, SURFACE INCLUD�1� COMBO UNIT. WITH BATTERY BACK -UP_ rr 'EM' LITHONI4, ELM2, WALL MOUNTED, DUAL HEADS. SURFACE INCLUDED EMERCaENCY LIGHT W /90 MINUTE BATTERIES. 4_4 .2c2-* V.� tp.o c r U Q E 0 Lr) LID t -d N m N • L.0 C4 r w L ro �` Q1 6-; rtd • `xx n rn c LC obc� x . o E 0 a C CONTACTOR LC -1 60 AMP 6 POLE ELECTRICALLY HELD > CONTACTOR W/ 120v COIL. ALL CONTACTS TO BE NORMALLY CLOSED. 0 0 1- 0 zto x0 CC CC 0 moo Lc) ¢Q EMAIL: sJdesign ®sarkujapon.cam NOTE: KITCHEN FIRE SUPRESSION SYSTEM MUST BE CONNECTED TO LANDLORDS MAIN FIRE ALARM BY LANDLORDS APPROVED FIRE ALARM CONTRACTOR AT TENANTS EXPENSE. LANDLORDS EQUIPMENT ENCLOSURE---- - 14,I6,1S H13 --• 1415 Hl-1 415 425 48 �-- GRIDDLE 3 NOTE: FRONT SERVERY LIGHTS AND MAIN SIGN MUST SE CIRCUITED THROUGH TIME CLOCK SET TO LANDLORDS SCHEDULE. RICE WARMER * SA REFRIGERATED BASE *11,4 1-100D LIGHTS w W U 0 (f) a w (1) w H- 14,16,18 CONTACTOR LC -2 JOB NUMBER J.21 O3 ELECTRICAL AUTO SHUTDOUJN CONTACTOR DETAIL H- 20,22 ,24 SCALE: 1/4' = l' =0' NO SCALE CORRECTION QTR# ELO 9'O5& SHEET NUMBER RECEIVED FEB 2 8 2008 PERMIT CENTER PL,l6vR AND PLANS 1 FILE tWY DATE OF ORIGINAL ISSUE 24 SEPTMSER 2007 P4NFLo SCHEDULE PANEL. SCHEDULE A IQKAIG ID <,41G NOTES: NOTES: DESCRIPTION ITEM NO. I a_ TRIP AMPS TOTAL WATTS A 5 C TOTAL WATTS TRIP AMPS o a_ DESCRIPTION ITEM No. NOTES: SOFT DRINK DISPENSER 19A GRIDDLE CKT 1 IF 3 30 6000 1 3 $ 1 9 11 13 1��16 1 I9 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 X4426 20 3 RTU • HACK ' L CA51 -4 REGISTER 2 1 20 250 660 20 1 MEAT SLICER 6000 4426 • • DRINK CARBONATOR 30 "11 20 1500 1440 4 6 1 PASS THROUGH REFRIGERATOR 15 L 6000 4426 1 20 600 1200 20 1 COOLER/LIGHTSMEATER 1 • i S GRIDDLE CKT 2 IF 3 30 6000 8320 45 3 TRANSFER 'A' 20 1 �� 17/18 L • • MEAT MIXER 29 6000 86-15 1632 1800 20 1 FREEZER CONDENSER 11 L �� ANSUL /WOOD LIGHTS 10 12 1 20 1200 1800 20 1 COOLER CONDENSER 6000 5122 • RICE WARMER SA 1 11 1000 G IDDLE 3 1S 3 25 4000 1101 20 3 EF -1 / MUA -1 WCP HOT FOOD WELL 65 14 2 30 1500 4000 114000 w , I v 1500 1420 20 1 • L ICE MACHINE 208 1 20 II I 20 1 51GN WATER HEATER 2213 3 20 2000 395 20 3 ! -2 54 WCP V •�•1 20 SPACE 2000 395 SPACE 21 23'1.• 22 24 W • V 2000 395 1 20 1200 120 20 I RECEPTACLE TOTAL 'A' 32842 MAI14 200 AMP MAIN LUGS ONLY 4 VOLTS 217/480 e TOTAL 'S' 3311 TOTAL 'C' 32644 98683 4 TOTAL ELECTRICAL LOAD ANALYSIS WCP= CIRCUIT THROUGH HOOD CONTROL I LIGHTING /51GNAGE AT 125%= 5.98 KVA FANS AT 125%. 1.81 KVA PANEL_ SEE DRAWING SWEET 1-12 FOR ADDITIONAL INFORMATION. THERMOSTATICALLY CONTROLLED KITCHEN EQUIPMENT AT 650 = 38.89 KVA 4 MISC. EQUIPMENT AT 100% = 8.49 KVA WATER HEATER ATI00%= 6.00 KW HVAC 1B 100% 1321 KW TOTAL LOAD= 80.59 KVA (91 AMPS) NOTE: CONDUIT AND CONDUCTORS FROM LANDLORD PROVIDED DISCONN^Ct IN LANDLORDS ELECTRICAL ROOM TO LANDLORD PROVIDED DISCONNECT N TENANTS SPACE 15 5r LANDLORD. NEW 211/480V 200 AMP METER AND SASE_ LANDLORDS ELECTRICAL ROOM a LANDLORD PROVIDED 480v 3P 200 AMP FUSED SERVICE DISCONNECT IN LANDLORDS ELECTRICAL ROOM. (1) # 6 CU GROUND TO SUILDING GROUNDING SYSTEM .VERIFY REQUIREMENT. TENANTS SPACE 4SOV, 3P /30 AMP NEMA 3 FUSED DISCONNECT AT ROOF MOUNTED MAKE UP AIR FAN MUA -1 TENANTS CONTRACTOR SHALL PROVIDE (3) *3/0 CU THWN (1) # CU GROUND (1) 2' CONDUIT LANDLORDS SHALL — PROVIDE (3) *3/0 CU THWN (1) *4 CU GROUND (1) 2' CONDUIT (3) *10 CU THWN (1) #10 CU GROUND (1) 3/4° CONDUIT MU411 EF1 1 480V, 3P/30 AMP NEMA 3R NON FUSED DISCONNECT AT ROOF MOUNTED EXHAUST FAN EF -1 AND EF -2 _ 4830V, 3F'/30 AMP NEMA 3R NON FUSED DISCONNECT AT ROOF MOUNTED HVAC UNIT RTU -1. EP2 J RTU J '(3) 010 CU TI-4WN (1) *12 CU GROUND (1) 3/4' CONDUIT REVIEWED FOR CODE COMPLIANCE NFPA70dNEC Mkt 21 2000 LANDLORD PROVIDED 480v ,3P 200 AMP FUSED SERVICE DISCONNECT N TENANTS SPACE FUSED AT 200 AMPS_ (1)* 4 CU GROUND TO BUILDING GROUNDING SYSTEM .VERIFY REQUIREMENT_ PANEL "1•-1 3P/4S (3) % CU THWN (1) % CU GROUND (1) 1' CONDUIT Oty Of Tukwila ILDDNG D I, N 1--1000 CONTROL PANEL TIMECLOCK NEW 211/450V , 3 PHASE PANEL 1-I' WITH 200 AMP MAIN LUGS ONLY. SEE PANEL SCHEDULE FOR ADDITIONAL INFORMATION. 01 c s 'VI0 30 KVA XEMR PANEL °A° NO SCALE NEW 120/208v , 3 PHASE PANEL 'A° WITH 100 AMP MAIN CIRCUIT BREAKER SEE PANEL SCHEDULE FOR ADDITIONAL INFORMATIOiL PROVIDE (4) *1 CU THWN AND (1)* 6 CU GROUND IN 1 -1/2' CONDUIT_ (1) * 6 CU GROUND TO BUILDING GROUNDING SYSTEM _VERIFY REQUIREMENT. LOB os& rLEC RIC4L DE-T-4 LS AND PANLL S k= RECEIVE FEB 2 8 2008 PERMIT CENT& PRELIMINARY DWGS. FOR L L. APPROVAL 0 TI- N 0 LL COMMENTS 0 0 0 0 CITY COMMENTS co 0 0 0 CITY COMMENTS co 0 CV N 0 m w a 0 <1.<1 <1<zr<g CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK DO NOT SCALE DRAWINGS EIt IL: sjdesign�sarkujapan.cam L z w 0 0 (1) J W Li U) CO ›- CO CO N a I CO CC 00 Z �7w Q 0 Q rr) O ro cnco 1— JOB NUMBER 7.21 i SHEET NUMBER DATE OF ORIGINAL ISSUE 24 SEFTM35Eia 2007 PANEL. SCHEDULE A IQKAIG NOTES: DESCRIPTION ITEM NO. O W TRIP AMPS TOTAL WATTS A 8 G TOTAL WATTS TRIP AMP.. O EL DESCRIPTION ITEM NO_ NOTES: SOFT DRINK DISPENSER 19A 1 20 600 1 3 5 1 9 11 13 15 11 19 21 23 25 27 29 31 33 35 31 39 41 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 SPACE • L CA51 -4 REGISTER 10 1 20 250 660 20 1 MEAT SLICER 28 • • DRINK CARBONATOR 30 1 20 1500 1440 20 1 PASS THROUGH REFRIGERATOR 15 L COLD PAN 14 1 20 600 1200 20 1 COOLER/LIGHTSMEATER • VEGETA13LE CUTTER 21 1 20 480 1200 20 1 EVAPORATOR FANS 17/18 L • • MEAT MIXER 29 1 20 1632 1800 20 1 FREEZER CONDENSER 11 L L ANSUL /WOOD LIGHTS e a 913 1 20 1200 1800 20 1 COOLER CONDENSER 18 L • RICE WARMER SA 1 20 1000 455 20 1 LIGHTS • • HOT FOOD WELL 65 2 30 1500 SPACE w , I v 1500 1420 20 1 LIGHTS • L ICE MACHINE 208 1 20 1000 1200 20 1 51GN • • MANAGER STATION 54 1 20 250 SPACE SPACE SPACE • 0 REFRIGERATED SASE 11A 1 20 1200 120 20 I RECEPTACLE • • SPARE I 20 SPACE SPARE 1 20 SPACE • SPARE 1 20 510 20 1 LIGHTS • • SPARE 1 20 SPACE SPARE 1 20 SPACE • SPACE SPACE • • SPACE SPACE TOTAL TOTAL TOTAL TOTAL TR4N5FORMER 'A' 8320 AMPS) 08 — MAIN 100 AMP MAIN CIRCUIT BREAKER '5' 5°15 VOLTS 120/208V 3 PHASE ITEM NUMBER DEVICES 'C' 8122 DENOTES KITCHEN EQUIPMENT DENOTES CIRCUITS WITH LOCK -ON SEE LOAD ANALYSIS BELOW LOAD ANALYSIS 0 — LIGHTING /SIGNAGE AT 125 % = 3.98 KVA THERMOSTATICALLY CONTROLLED KITCHEN EQUIPMENT AT 65% = 1.10 KVA MISC. EQUIPMENT AT 100% 8.49 KVA TOTAL LOAD= 22.11 KVA (62 MU411 EF1 1 480V, 3P/30 AMP NEMA 3R NON FUSED DISCONNECT AT ROOF MOUNTED EXHAUST FAN EF -1 AND EF -2 _ 4830V, 3F'/30 AMP NEMA 3R NON FUSED DISCONNECT AT ROOF MOUNTED HVAC UNIT RTU -1. EP2 J RTU J '(3) 010 CU TI-4WN (1) *12 CU GROUND (1) 3/4' CONDUIT REVIEWED FOR CODE COMPLIANCE NFPA70dNEC Mkt 21 2000 LANDLORD PROVIDED 480v ,3P 200 AMP FUSED SERVICE DISCONNECT N TENANTS SPACE FUSED AT 200 AMPS_ (1)* 4 CU GROUND TO BUILDING GROUNDING SYSTEM .VERIFY REQUIREMENT_ PANEL "1•-1 3P/4S (3) % CU THWN (1) % CU GROUND (1) 1' CONDUIT Oty Of Tukwila ILDDNG D I, N 1--1000 CONTROL PANEL TIMECLOCK NEW 211/450V , 3 PHASE PANEL 1-I' WITH 200 AMP MAIN LUGS ONLY. SEE PANEL SCHEDULE FOR ADDITIONAL INFORMATION. 01 c s 'VI0 30 KVA XEMR PANEL °A° NO SCALE NEW 120/208v , 3 PHASE PANEL 'A° WITH 100 AMP MAIN CIRCUIT BREAKER SEE PANEL SCHEDULE FOR ADDITIONAL INFORMATIOiL PROVIDE (4) *1 CU THWN AND (1)* 6 CU GROUND IN 1 -1/2' CONDUIT_ (1) * 6 CU GROUND TO BUILDING GROUNDING SYSTEM _VERIFY REQUIREMENT. LOB os& rLEC RIC4L DE-T-4 LS AND PANLL S k= RECEIVE FEB 2 8 2008 PERMIT CENT& PRELIMINARY DWGS. FOR L L. APPROVAL 0 TI- N 0 LL COMMENTS 0 0 0 0 CITY COMMENTS co 0 0 0 CITY COMMENTS co 0 CV N 0 m w a 0 <1.<1 <1<zr<g CONTRACTOR SHALL VERIFY ALL DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECTS OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK DO NOT SCALE DRAWINGS EIt IL: sjdesign�sarkujapan.cam L z w 0 0 (1) J W Li U) CO ›- CO CO N a I CO CC 00 Z �7w Q 0 Q rr) O ro cnco 1— JOB NUMBER 7.21 i SHEET NUMBER DATE OF ORIGINAL ISSUE 24 SEFTM35Eia 2007