Loading...
HomeMy WebLinkAboutPermit EL08-0064 - WESTFIELD SOUTHCENTER MALL - LITO PANIDAWESTFIELD 2800 SC MALL 07 -23 -08 EL08-064 Cit3af Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2800 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -064 Issue Date: 03/12/2008 Permit Expires On: 09/08/2008 Tenant: Name: WESTFIELD MALL INTERIOR RENOVATION Address: 2800 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WEA SOUTHCENTER LLC Phone: Address: 11601 WILSHIRE BLVD , LOS ANGELES CA Contact Person: Name: Address: Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW Phone: Phone: Expiration Date: 12/16/2009 DESCRIPTION OF WORK: WORK IS LIMITED TO INTERIOR RENOVATION AND SELECTED AREA IMPROVEMENTS TO EXISTING MALL. NEW POLICE SUB - STATION OFFICE SPACE, NEW RESTROOM, AND SELECTED KIOSK AREA FOR NEW TENANT /FUTURE TENANT LOCATION. Value of Electrical: 250,000.00 Fees Collected: $4,127.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and Date: 074 (Z4Di ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied itl,, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ce of wor I am authorized to sign and obtain this electrical permit. Signature / a �L Date: 3) I L I D 2r' Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -064 Printed: 03 -12 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2800 SOUTHCENTER MALL TUKW WESTFIELD MALL INTERIOR RENOVATION Permit Number: Status: Applied Date: Issue Date: EL08 -064 ISSUED 01/17/2008 03/12/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 7` ` Date: 3112-1 Ui Print Name: /(/�lG���LZ ��l(C• doc: Cond -Elec EL08 -064 Printed: 03 -12 -2008 CITY OF TUKWIta Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa. us Electrical Permit No. Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: n y''KiiIng Co Assessor's Tax No.: p f}�Li11►iT �" I !A V 4 IN Suite Number: Floor: Tenant Name: WesrriarD Property Owners Name: OVSnol olJ ' CAZPOP A1'IOa t IN G. Mailing Address: I1GFO1 Wit.1741112 uevfi b l2'fl+ Vtota.. Los AlkteL1:S CA VMS- 1744 Zip ( Nit-12o --00c 0 New Tenant: ❑ Yes ❑..No City State CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: LI TD t ?4117► Mailing Address: ¶O' li Arlorg M t 51.4ITE. 160 Day Telephone: la, - 44.4 - S 7vrn,c i)1A ga14.4. E -Mail Address: UPprotarkstx,capomp. Pout City State Fax Number: ZOO -1 /,Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: Ltrii= --- Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 2.5101 OOo Scope of Work (please provide detailed information): OP- 42.10— L5 11 al tanD To IN it lei R- rsevr► na id wA- v11C.+rJ mertovtivi w Tg 1° 6Xt, -n e.L.e Niao % lAce- SAS -s1A -p oil opfic,E Spate 4 N7'14-$ ReSTAtsorvk sr'I.we nso 41051/... A pow nW - ti= 'NAIQT / -t ' fi ti,arh p t . Will service be altered? ❑ Yes ►: No Adding more than 50 amps? J Yes ❑ No Type of Use: {2c--r t L/ O C.e--- Type of work: ❑ New Ul Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy El Seattle City Light El Service Change ❑ Fire Alarm H: Applicahons\Forms- Applications On Lne\4 -2007 - Electrical Permit Application.dnc bh NI Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 6Z,d. Movo Mme . Mailing Address: 611173 So.rlt•4Geaji -ttle, HALL. 1 Day Telephone: S AT I- Date: Zio Zo6- 3c11- 4,7 City PAC State `t8126 Zip Date Application Accepted: ®� Date Application Expires: D j (q..4 i7' Staff Initials: H:WpplicationsWomns- Appl matrons On Ltne4 -2007 - Electncal Permit Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -064 Address: 2800 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/17/2008 Applicant: WESTFIELD MALL INTERIOR RENOVATION Issue Date: Receipt No.: R08 -00712 Initials: User ID: Payee: JEM 1165 Payment Amount: $3,302.00 Payment Date: 03/12/2008 09:05 AM Balance: $0.00 SEA -TAC ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8781 3,302.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 3,302.00 Total: $3,302.00 -fir+ • /2 doc: Receipt -06 Printed: 03 -12 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -064 Address: 2800 SOUTHCENTER MALL TURW Status: PENDING Suite No: Applied Date: 01/17/2008 Applicant: WESTFIELD INTERIOR RENOVATION Issue Date: Receipt No.: R08 -00155 Initials: ]EM User ID: 1165 Payment Amount: $825.50 Payment Date: 01/17/2008 11:38 AM Balance: $3,302.00 Payee: WESTFIELD TRANSACTION LIST: Type Method Description Amount Payment Check 06010488 825.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES iEri j.:1 1 r n N .;;+•,.: tJI 000.345.832.00.0 825.50 Total: $825.50 7361 01/17 9710 TOTAL 825.50 doc: Receiot -06 Printed: 01 -17 -2008 INSPECTION RECORD Retain a copy with permit 6tolc- 014 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION It 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 6 0 Project: i i1 ffi 1 We Type of Inspection: 7-1 00 G3 Address: Date Called: t)R- f /JAL - f LeeK j<,'"_s, Special Instructions: Date Wanted: / Z� a m. Requester: Phone No: pproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 0/2 — CL/- C� — 1/111/E6 G3 I/I t)R- f /JAL - f LeeK j<,'"_s, 614- F , ,e t- - /Jz-4) coafpw /.,/KP;hk3 Date: j �34v0 Inspector:...1;i t /„ (e /6 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 64-061 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION A- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: , , , `_r ejA) Type of Inspection: Address: zgoo 6 ` t Date Called: Special Instructions: Date Wanted: 1/II a:m: Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: o I-I Inspector: Date: I pot' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: U. ::_..:___ �..� - --- ALL.- .._.ik._��.... INSPECTION RECORD � D,/ Retain a copy with permit a ' UP INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: LA/ + tt «wv. 1 Type of Inspection: VV Address: .(' "���•'J�,�` 1 / Date Called: Special Instructions: 1 Date Wanted: (O /1 a.m. Requester: Phone No: Approved per applicable codes. Ij Corrections required prior to approval. COMMENTS: - 'ozeasiik6 709 Inspector: Date: ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION t' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /11,,5 II f f L A Type of Inspection: /CC i Address: Date Called: Special Instructions: Date Wanted: /�, ,�/ /9` a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. • OMMENTS: NA r ,/1'i1 VY S W MYL f F ���� r MS "11 / V c.: Ins a r p1014- 2. MI6/ Date W9 / r ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ,. L INSPECTION NO. INSPECTION RECORD Retain a copy with permit �uJfs UC4 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project: Ty. • . f , s • io 0 - :T h T/t L f /N, L- — l idr{ li/1 li Date Called: ;�,��C. -- 406 k s/ W- eixkcs ,eviv /1/14c-y" Special Instructions: 7Ti bN / )LG- Date Wanted: cv/3 a.m. P.m. Requester: Phone No: / pproved per applicable codes. D Corrections required prior to approval. COMMENTS: 0— WA 1, cmt) M - itffh) I17 / e;/ li T Y 0 - :T h T/t L f /N, L- — l Al _<1 G J/, /7Y &c/cf ,Ale [q,2c X - '�fsr s/' 4A 01 ;�,��C. -- 406 k s/ W- eixkcs ,eviv /1/14c-y" _ 0111--gi� fL) ,l ZC'4z?n - 7Ti bN / )LG- nspe /44- / M4/91/CP Date: 4// $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit Ec4-N4 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ? 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 \A Project: j t5Tri e� 11 t 1 Type of Inspection: QO Address:2p l Date Called: Special Instructions: Date Wanted: j 5 3, Q P.m. Requester: Phone No: ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 17A- 0 . IC , — JnIDr 8.51.9$ 1-o-of' S cogirk - L(AiSCiza-T 5 6.19II1- 0,1.1 TD Inspector: SI 46thInleit ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 6.015- 06y INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: (.51-(0,9 Type of Inspection: 7a0?......- Address: Zoo fi v _ Date Called: Special Instructions: gof et- r 3tOJ "'1 6 "-&C.4 Date Wanted: 3o c.rn Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: OA( - 50.110e AJorf = L 4036— P C — P` re-041.• Inspector: 6151/dett_ Date: 40513 ` 0 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: l/ INSPECTION NO. INSPECTION RECORD Retain a copy with permit fuj- o6Q PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: L / _ 1A)/9-i' Aec A �'`1"10f(�,�/0/ Type of Inspection: _,/ 0- .3 2 GEti / �,61'Lfi Date Called: Special Instructions: Date Wanted: / 2"--1..--` a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: piq 0(, cpt_,iiGS— Ews7-2r116- ime4 Inspecto . go /ic .)u744,41/0 Dated /0 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: A $7 A#SM446 011/6 07110A2 Type of Inspectio / 7a 3 immosimmirm■m Address: p�C7 Z �tp m 4,VT ��A- Date Called: Special Instructions: Date Wanted : -4 d a.m. p.m. Requester: Phone No: pproved per applicable codes. rrections required prior to approval. OMMENTS: a immosimmirm■m r - &4 s-L -co_ > TI 1 - iax WAIIIMSNIMINFIWAIMENII idgira.k J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit Ifio -06 4 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Pro ect: Type of Inspection: —20 / Address: es � Date Called: -- A Ec.7-41 // s'y 4 .J021)ST, of special Instructions: Date Wanted: _,,, St/ 5) a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: Oft — 1)t CL'9 8 -- ,V,gtC- i ktr< -71W . A Se/94 .c -- A Ec.7-41 // s'y 4 .J021)ST, of Inspecto, 1/1 fia7,444/V/6// Date: (I/ 7 �& r $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 f toi- O4 1/ t4 ST f /t4 ii(,i74 Type of Inspection: _20 _63 Address: Pa8 Sal kC-4 /L Date Called: Special Instructions: ,i Date Wanted: , / ;� a.m. p.m. Requester: Phone No: \r) pproved per applicable codes. Corrections required prior to approval. OMMENTS: sP/9 01L- 041-,) sica4/ff officT Inspe Date / 4 /J„, 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address INTERIOR RENOVATION - SOUTHCENTER MALL Date 1/16/2008 633 Southcenter Parkway For Building Department Use Tukwila, WA 98188 -2888 Applicant Name: DLR Group Applicant Address: 901 5th AVE, Suite 700 Applicant Phone: Seattle, WA 98164 Project Description 348.0 ❑ Plans Included requirements. [_] New Building ❑ Addition J Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option O Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Fixture Description Allowed Area in ft2 Allowed x Area Occup• l ?�iC i Watts per ft2 " First Floor - General Office �VpE®� COMPLIANCE CODE COMPLIANCE l 1.00 ° 348.0 348.0 First Floor - drat office NFPA 70 - NEC 1.00 184.0 184.0 Floor - jjjjj,,,,, a Restroom 0.80 92.0 73.6 zst Floor - Storage FI:R P 2008 0.50 61.0 30.5 irat Floor - o4A Locker Room 0.80 119.0 95.2 first Floor - fiS Dispatch Office 1.00 221.0 221.0 1 651W 7 rst Floor - 105A Waitin g Room ity of u cuvila LEARLDING 0.80 110.0 88.0 DIVISION, "* From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1040.3 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed First Floor - jj,, 6 2'x2' Recessed Fluorescent Light with (2) BE 40W lamp 7 76.0 532.0 F9irat Floor - 7 ] First 2'x4' Recessed Fluorescent Light with (2) T5 28W lamp 3 60.0 180.0 Floor d8 10" Surface mounted fixtrue with (2) CF13DD /E lamp 2 13.0 26.0 rat Floor - ], 2 2'x4' Recessed Fluorescent Light with (2) T5 28W lamp 1 60.0 60.0 Yirst Floor - 04]� drat 2'x4' Recessed Fluorescent Light with (2) T5 28W lamp 1 60.0 60.0 Floor - 5 2'x4, Recessed Fluorescent with (2) T5 28W lamp ht g amp 2 60.0 120.0 OSAt Floor - 2'x4' Recessed Fluorescent Light with (2) T5 28W lamp 1 651W --‘r-ii /E-1") 6p0.0 `I.Jtl:kii j l;l_.1`;1 Est Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1038.0 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. FILE COPY 161X5°D(Pial 2006 Washington State Nonresidential Energy Code Compliance Form Ulterior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers °Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liahtina Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces° 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall °'4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address INTERIOR RENOVATION - SOUTHCENTER MALL Date 1/16/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E2.2 yes 1513.2 Area controls Maximum limit per switch E2.2 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n . a . (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations E2 .2 n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n. a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 'Max. watts 'Indicate watts for each exit sign IE2.2 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E4.1 n. a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n. a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'Indicate size and efficiency 1 I If "no" is circled for any question, provide explanation: Wstfieff January 15, 2008 Don Tomaso, Fire Marshal Tukwila Fire Department 444 Andover Park East Tukwila, Washington 98188 RE: Westfield Southcenter Existing Mall Renovation Permit Application #D07 -197 Westfield Southcenter 633 Southcenter Mall Tukwila, Washington Dear Mr. Tomaso, Westfield understands that the Tukwila Fire Department is requiring the means of egress lighting system in the existing mall to be on emergency power. These areas include common public areas and service corridors. Existing interior tenant spaces and anchor tenant buildings will not be included in this upgrade. The construction of these upgrades to the existing lighting systems will be completed prior to the opening of the new mall expansion. These improvements are currently being designed under a design -build contract with SeaTac Electric, and will be submitted to the city for plan review and approval under its own permit application. Westfield therefore requests that the city issue the renovation building permit for the existing mall exclusive of these upgrades to the existing lighting system, with the understanding that the installation of these upgrades will be in place prior to the opening of the new mall expansion. Sincerely, Par P\o-± Ray Marter Technical Director of Design Westfield Southcenter cc: Bob Benedicto, Building Official City of Tukwila Page 1 of 1 REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC FEB 2 8 2008 CI Of Tukwila 3 IN ION FILE COPY ',PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: ELOg -064 DATE: 01 -17 -08 PROJECT NAME: WESTFIELD MALL INTERIOR RENOVATION SITE ADDRESS: 2800 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 0. •/ Bulefing 1 ivislon -Fig) Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 01 -22-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route F7f Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02-19-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Doaunentslouting slip.doc 2.28 -02 Look Up a Contractor, Electron or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SEATAEI077RW Licensee Name SEA TAC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601510212 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 7056 S 220TH ST Address 2 City KENT County KING State WA Zip 98032 Phone 2538725553 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/16/1993 Expiration Date 12/16/2009 Suspend Date Separation Date Parent Company Previous License SEATAEC131QC Next License Associated License HARGRT *974CD Master Electrician Information License HARGRT *974CD Name HARGREAVES, TOM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM AGENT 12/17/1993 HARGREAVES, TOM PRESIDENT 12/17/1993 HARGREAVES, • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SEATAEI077RW 03/11/2008 SEPARATE PERMIT REQUIRED FOR: VIVI6chanical 0 Electrimaf alumbing arGas Piping City of Tukwila BUILDING DIVISION , • W N F %4) n vco < 0 0 I N E P I 1- a 0 N oQ n � U ABBREVIATIONS (SOME ABBREVIATIONS MAY NOT APPLY) A AMP AB AC AC AFF AHU AIC ALT ARCH ATS AWG BEL BKR BLDG C CCTV CKT /CCT CKT BKR CLG CO (GOMM CU DC D DDC DEG DISC SW DISC DWG EC EDH EF EH ELEC ELEV EMER EMD EMS EMT EP EPO EQUIP WC (E) EXIST EXT FA FA FACP FBOIC FC FCU FD FDR FT FLUOR FS FSD FT F1JT GA GC GEN GFI GFP GND CRC HID HOA HP HP HTG HZ TES IG IMC IN KV KVA KVAR KW KWH LT LTG LV MAN MATV IAAU MAX MCA MCB MCC MCM MECH MFR MFRG MG MN MLO MTD MTG N N/A NC NEC NEMA NIC NL NO NO NTS OC OFOI OHP OHT P P PB PB PF PH PNL PWR RECP RM SCHED SCR SD SEC SES SF SHT SPEC SW SWBD SYM TB TC TELE TGL TV 1VSS 1W UG UGE UGT UH UL UNO UPS VFD VIA w W/o wH HHM NIP XFMR i.e. Z 0 AMPERE ABOVE AIR CONDITIONING UNIT ALTERNATING CURRENT ABOVE FINISH FLOOR AIR HANDLING UNIT AMPS INTERRUPTING CAPACITY ALTERNATE ARCHITECTURAL AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE BELOW BREAKER BUILDING CONDUIT CLOSED CIRCUIT TELEVISION CIRCUIT CIRCUIT BREAKER CEILING CONDUIT ONLY COMMUNICATIONS COPPER DEDICATED DIRECT CURRENT DIRECT DIGITAL CONTROL DDEPRESS(ION)(ED) DISCONNECT SWITCH DISCONNECT DRAWING ELECTRICAL CONTRACTOR OR EMPTY CONDUIT ELECTRIC DUCT HEATER EXHAUST FAN ELECTRICAL HEATER ELECIRIC(AL) ELEVATOR EMERGENCY ESTIMATED MAXIMUM DEMAND ENERGY MANAGEMENT SYSTEM ELECTRICAL METAWC TUBING EXPLOSION PROOF EMERGENCY POWER OFF EQUIPMENT ELECTRIC WATER COOLER ELECTRIC WATER HEATER EXISTING EXISTING EXTERIOR FIRE ALARM FRESH MR FIRE ALARM CON1ROL PANEL FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FOOT CANDLE FAN COIL UNIT FIRE DAMPER FEEDER FINISH FLOOR FLUORESCENT FLOW SWITCH ARE /SMOKE DAMPER FEET (FOOT) FUTURE GAUGE GENERAL CONTRACTOR GENERATOR GROUND FAULT INTERRUPTER GROUND FAULT PROTECTION GROUND GALVANIZED RIGID CONDUIT GALVANIZED RIGID STEEL HIGH INTENSITY DISCHARGE HAND OFF AUTOMATIC HEAT PUMP HORSEPOWER HERTZ G INTERCOM ILLUMINATING ENGINEERING SOCIETY ISOLATED GROUND INTERMEDIATE METAL CONDUIT INCH KILOVOLT KILOVOLT AMPERES KILOVOLT AMPERES REACTIVE KILOWATT KILOWATT HOUR LIGHT LIGHTING LOW VOLTAGE MANUAL MASTER ANTENNA TELEVISION MAKEUP AIR UNIT MAXIMUM MINIMUM CIRCUIT AMPS MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER THOUSAND CIRCULAR MILLS MECHANICAL MANUFACTURER MANUFACTURING MOTOR GENERATOR METAL HALIDE MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOUNTING NEUTRAL NOT APPUCABLE NORMALLY CLOSED NATIONAL ELECTRIC CODE NATIONAL ELECTRICAL MANUFACTURERS ASSN. NOT IN CONTRACT NIGHT LIGHT NORMALLY OPEN NUMBER NOT TO SCALE ON CENTER OWNER FURNISHED OWNER INSTALLED OVERHEAD POWER OVERHEAD TELEPHONE POLE PUMP PULL BOX PUSH BUTTON POWER FACTOR PHASE PANEL POWER RECEPTACLE ROOM SCHEDULE SHORT CIRCUIT CURRENT RATING SMOKE DETECTOR SECONDARY SERVICE ENTRANCE SWITCHBOARD SUPPLY FAN SHEET SPECIFICATION SWITCH SWITCH BOARD SYMMETRICAL TERMINAL BOX TIME CLOCK TELEPHONE TOGGLE TELEVISION TRANSIENT VOLTAGE SURGE SUPPRESSION TYPICAL UNDER GROUND UNDER GROUND ELECTRICAL UNDER GROUND TELEPHONE UNIT HEATER UNDERWRITERS LABORATORIES UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VOLT VARIABLE FREQUENCY DRIVE VOLTMEILR WATT WITH WITHOUT WATER HEATER WATT HOUR METER WEATHERPROOF TRNSFORMER IMPEDANCE AND AT THAT IS NUMBER O E N E RAL NOTES (SOME GENERAL NOTES MAY NOT APPLY) 1. DRAWINGS INDICATE GENERAL DESIGN INTENT AND PLACEMENT OF EQUIPMENT. INFORMATION SHOWN IS DIAGRAMMATIC AND DOES NOT NECESSARILY SHOW EVERY REQUIRED ACCESSORY, EXTENSION OR MOUNTING OPTION. PROVIDE EQUIPMENT COMPLETE WITH ALL NECESSARY ACCESSORIES AND HARDWARE IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS - PROVIDE COMPLETE AND OPERATING SYSTEMS MEETING THE DESIGN INTENT. 2. D0 NOT SCALE DRAWINGS. COORDINATE ELECTRICAL WORK WITH THE WORK OF OTHER 'TRADES. LOCATIONS OF DEVICES AND EQUIPMENT SHALL SUIT SITE CONDITIONS. 3. CEIUNG CAVITY SPACES AND SPACES BELOW ACCESS FLOORS SHALL BE CAREFULLY COORDINATED WITH OTHER TRADES. RACEWAY AND SYSTEM ROUTINGS ARE DIAGRAMMATIC AND FOR COORDINATION PURPOSES ONLY. 4. VERIFY THE EXACT HEIGHT AND LOCATIONS OF DEVICES MOUNTED IN CASEWORK WITH CASEWORK DRAWINGS, AS WELL AS LOCATIONS AND ALL ELECTRICAL REQUIREMENTS OF DEVICES MOUNTED ABOVE COUNTERS PRIOR TO ROUGH -IN. 5. PROVIDE A CONTINUOUS GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS, RACEWAYS, FEEDERS AND BRANCH CIRCUITS WHETHER INDICATED OR NOT SIZED IN ACCORDANCE WITH THE NEC. PROVIDE A SEPARATE CONTINUOUS GREEN WITH YELLOW TRACER ISOLATED GROUND CONDUCTOR, WHERE INDICATED, SIZED IN ACCORDANCE WITH THE NEC. 6. CONDUCTOR HASH MARKS, FOR BRANCH CIRCUITS, ARE PROVIDED FOR EASE OF ESTIMATION AND ARE DIAGRAMMATIC ONLY. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND PROVIDING REQUIRED WIRECOUNT AND SIZING CONDUIT ACCORDINGLY. THE OWNER SHALL NOT BE LIABLE FOR ANY COST INCREASES DUE TO WIRECOUNT CHANGES. 7. ALL SYSTEMS CABLES ROUTED EXPOSED ABOVE SUSPENDED CEIUNGS AND BELOW RAISED ACCESS FLOORS SHALL BE PLENUM RATED. 8. ALL PENETRATIONS OF FIRE RATED FLOORS OR WALLS SHALL BE PROTECTED BY MATERIALS AND INSTALLATION DETAILS THAT CONFORM TO UNDERWRITER LABORATORIES LISTINGS FOR THROUGH PENETRATION FIRE STOP SYSTEMS. THE CONTRACTOR SHALL SUBMIT SHOP DRAWING DETAILS TO THE ARCHITECT/ENGINEER WHICH SHOW COMPLETE CONFORMANCE TO THE U.L USING. THE DETAILS SHALL BE SPECIFIC FOR EACH PENETRATION WITH ALL VARIABLES DEFINED. THESE SHOP DRAWING DETAILS SHALL BE AVAILABLE ON SITE FOR REVIEW BY ENFORCING AUTHORITY INSPECTORS. 9. FOR CONNECTION REQUIREMENTS TO NON- MECHANICAL EQUIPMENT SEE THE EQUIPMENT AND UTIUTY SCHEDULE DRAWINGS AND /OR ELECTRICAL PANEL SCHEDULES. 10. FOR CONNECTION REQUIREMENTS TO MECHANICAL EQUIPMENT SEE THE MECHANICAL EQUIPMENT SCHEDULES, AND /OR ELECTRICAL PANEL SCHEDULES LOCATED IN THE SPECIFICATIONS OR ON THESE DRAWINGS. 11. SEE MECHANICAL AND PLUMBING DRAWINGS TO CONFIRM LOCATIONS OF ALL HVAC EQUIPMENT, WATER HEATERS, PUMPS, EXHAUST FANS, FIRE /SMOKE DAMPERS, THERMOSTATS, CONTROL DEVICES, CONTROL PANELS, EMCS EQUIPMENT, ETC. COORDINATE WITH MECHANICAL CONTRACTOR AND SPECIFICATIONS TO PROVIDE A COMPLETE RACEWAY SYSTEM FOR CONTROL WIRING WHERE REQUIRED. PRIOR TO ROUGH-IN, REVIEW MECHANICAL/PLUMBING SHOP DRAWINGS AND SUBMITTALS TO VERIFY POINT OF CONNECTION(S), LOADS, VOLTAGE, PHASE, ETC. (COORDINATE DISCREPANCIES WITH ENGINEER.) ADJUST FUSE SIZES AND /OR BREAKERS PER RESPECTIVE EQUIPMENT MANUFACTURERS RECOMMENDATIONS, FUSES FEEDING MECHANICAL EQUIPMENT, SHALL BE DUAL ELEMENT-TIME DELAY, CLASS RK -5, UNO. 12. PROVIDE FUSIBLE DISCONNECTS PER NEC FOR AU. EQUIPMENT FURNISHED UNDER OTHER DIVISIONS OF THE CONTRACT WHICH ARE LABELED OR LISTED TO BE FUSED. 13. IN ELECTRICAL/MECHANICAL EQUIPMENT ROOMS, STORAGE AND ALL AREAS WITH EXPOSED CEILING STRUCTURES, PROVIDE METAL STRUTS AND SUSPEND FLUORESCENT LIGHTING FIXTURES WITH 3/8" DIA. STEEL RODS (CHAINS WILL BE UNACCEPTABLE). SUSPEND SO THAT BOTTOM OF FIXTURES ARE ALIGNED WITH BOTTOM OF HVAC DUCTWORK OR AS NOTED (COORDINATE WITH MECHANICAL DWGS.) DO NOT ATTACH OR SUPPORT FROM DUCTWORK OR HVAC EQUIPMENT. 14. PROVIDE 4 INCH MINIMUM RAISED CONCRETE HOUSEKEEPING PADS FOR ALL FREE STANDING ELECTRICAL DISTRIBUTION EQUIPMENT. (EMERGENCY GENERATOR, SWITCHBOARDS, TRANSFORMERS, ETC.) CONFIRM FINAL PAD SIZES WITH MANUFACTURER'S SHOP DRAWINGS PRIOR TO CONSTRUCTION OF PAD. 15. PROVIDE GFCI RECEPTACLES WITH WP OUTLET ENCLOSURES ON ROOF WITH IN 25' --0° OF HVAC EQUIPMENT PER N.E.C. RECEPTACLE SHALL BE UNISTRUT SUPPORTED AND NOT MTD ON MECH EQUIP. VERIFY RECEPTACLE LOCATION WITH FINAL EQUIPMENT LOCATIONS AS SHOWN ON MECHANICAL DRAWINGS. A 1 ELECTRICAL SYMBOLS (SOME ELECTRICAL SYMBOLS MAY NOT APPLY) LIGHTING IFLUORESCENT LIGHT FIXTURE, -A" INDICATES FIXTURE SEE FIXTURE SCHEDULE. LIGHT FIXTURE WITH EMERGENCY BATTERY PACK I--o -I FLUORESCENT STRIP LIGHT 0 OS s so WALL MOUNTED TWO HEAD EMERGENCY LIGHT FIXTURE WITH BATTERY PACK EXIT SIGN, DOUBLE FACE CEILING MOUNTED, DIRECTIONAL ARROW AS INDICATED EXIT SIGN, SINGLE FACE WALL MOUNTED, DIRECTIONAL ARROW AS INDICATED OCCUPANCY SENSOR SWITCH, SINGLE POLE SWITCH, OCCUPANCY SENSOR POWER TYPE. CIRCUIT HOME RUN - -0 CONDUIT TURNING UP -* CONDUIT TURNING DOWN -3 CONDUIT WITH CAP -�- CONDUIT HAZARDOUS LOCATION SEAL 11 CONDUIT CONCEALED W CEILING OR WALLS, POWER CONDUIT CONCEALED UNDER FLOOR OR UNDER GROUND WRING IDENTIFICATION. SHORT HASH MARKS INDICATE QUANTITY OF PHASE CONDUCTORS, LONG HASH MARK INDICATES NEUTRAL. REVERSE SHORT HASH MARK INDICATES ISOLATED GROUND, AND ' S " INDICATES CONTINUATION. A CONTINUOUS GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR TO BE PROVIDED IN ALL FEEDERS AND BRANCH CIRCUITS SIZED IN ACCORDANCE WITH THE NEC. CUM 0 GEN TRANSFORMER BRANCH CIRCUIT PANEL BOARD DISTRIBUTION PANEL BOARD EQUIPMENT CABINET SWITCHBOARD CURRENT TRANSFORMER ENCLOSURE METER GENERATOR AUTOMATIC TRANSFER SWITCH SYSTEM GROUNDING ELECTRICAL VAULT ELECTRICAL PULL BOX MOTOR CONNECTION, HORSEPOWER AS INDICATED MOTOR RATED TOGGLE SWITCH MAGNETIC MOTOR STARTER DISCONNECT SWITCH, WITH FUSE DISCONNECT SWITCH, WITHOUT FUSE COMBINATION MOTOR STARTER DUPLEX RECEPTACLE FOURPLEX RECEPTACLE Q FLUSH FLOOR OUTLET BOX FLUSH FLOOR BOX WITH DUPLEX RECEPTACLE FLUSH FLOOR BOX WITH FOURPLEX RECEPTACLE o-e CT CABLE TRAY SMR -- SURFACE METAL RACEWAY BW BUSWAY Q JUNCTION BOX FLUSH JUNCTION BOX, WALL MOUNTED EQUIPMENT CONNECTION FIRE ALARM FACP FILE ALARM CONTROL PANEL FILE ALARM ANNUNCIATOR PANEL FIRE ALARM STROBE SMOKE DETECTOR - PHOTOELECTRIC TYPE SPECIAL SYSTEMS • TELEPHONE OUTLET, WALL TELEPHONE OUTLET, +60' AFF. PAY TELEPHONE OUTLET. +60" AFF. FLUSH FLOOR BOX WITH TELEPHONE OUTLET 0:11 04 1 • SPEAKER, CEILING TELEPHONE BACKBOARD, SIZE AS SHOWN TELEPHONE/DATA OUTLET. PROVIDE SINGLE GANG COVER PLATE AND 4" SQUARE BACKBOX WITH SINGLE GANG MUD -RING. PROVIDE 1" EMT C.O. TO ACCESIBLE CEIUNG SPACE OR CABLE TRAY. PROVIDE INSULATED BUSHING ON CONDUIT END AND PULL UNE IN CONDUIT WITH LABELING BOTH ENDS. FLUSH FLOOR BOX WITH DATA OUTLET FLUSH FLOOR BOX W/ TELEPHONE /DATA OUTLET ONELINE 11 1 I, UTILITY TRANSFORMER Q CURRENT TRANSFORMER CABINET METER MAIN SWITCHBOARD ELECTRICAL GROUND 171 WATER PIPE GROUND CONNECTION 'NI JUMPER SWITCHBOARD MAIN OR FEEDER BREAKER �-- BRANCH CIRCUIT BREAKER �-►�- FUSED SWITCH .-4"--8:0-40- FUSED SWITCH /STARTER ER PANEL u PANEL - SECOND EDITION TRANSFORMER 1 TRANSFORMER JUNCTION BOX 0 MOTOR � COMBINATION STARTER/DISCONECT i ATS FUSED DISCONECT GENERATOR AUTOMATIC TRANSFER SWITCH CONNECTION DOT OUTLET MOUNTING HEIGHT SCHEDULE DEVICE CENTERLINE OF BOX ABOVE FINISH FLOOR (U.O.N) RECEPTACLE 18 INCHES DATA OUTLET 18 INCHES TELEPHONE OUTLET 18 INCHES FIRE HORN WITH VISUAL WARNING 90 INCHES TO TOP PULL STATION 42 INCHES DISCONNECT SWITCH 54 INCHES MOTOR STARTER 54 INCHES ACH - ABOVE COUNTER HEIGHT 42 INCHES PANELBOARD 72 INCHES TO TOP FIRE ALARM CONTROL PANEL 72 INCHES TO TOP INDEX OF DRAWINGS E0.1 ELECTRICAL SYMBOL ABBREVIATIONS ES1.0 ELECTRICAL SITE PLAN 01.E1 DEMOLITION AT MACY'S COURT POWER AND SYSTEMS PLAN D1.E2 DEMOLITION SECURITY OFFICE POWER AND SYSTEMS PLAN D1.E3 DEMOUTION MACYS COURT UGHITN0 PLAN D1.E4 DEMOLITION SECURITY OFFICE UGHTING PLAN E1.1 PARTIAL WEST ENTRY POWER PLAN E1.2 PARTIAL MACY'S COURT POWER AND SYSTEMS PLAN E1.3 NEW POLICE SUB - STATION POWER AND SYSTEMS PLAN E1.4 PARTIAL NORTH MALL POWER PLAN E1.5 PARTIAL EAST MALL POWER PLAN E1.6 PARTIAL SOUTHWEST MALI- POWER PLAN E2.1 PARTIAL MACYS COURT LIGHTING PLAN E2.2 NEW POLICE SUB - STATION LIGHTING PLAN E3.1 EXISTING LANDLORD POWER DISTRIBUTION ONE -UNE DIAGRAM E3.2 EXISTING WEST TENANT POWER DISTRIBUTION ONE -LINE DIAGRAM E4.1 SCHEDULES --- , - - • -•-t , • R EViSIONS No clang st -till b n -icGr1 to the S; of work +ter ;out p: io( approv& of Tukwila F3uii„ir ig Div si n. NOTE: Revisions will redo re a new plan submittaf and may include ads iV ;nai plan review fees. APPROVED P" , ",!S !+.';L1 F.PEC FlCAT"0p!S e!-L LL I• "T !7.!'' '"I'A "�uED MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILD= OF lC AI ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS NM fS ,,t1S. ZiCT TO FIELD INSPECTIONS --REVIEWED FOR CODE COMPLIANCE NFPA 70 NEC FEB 2 8 2008 City Of Tukwila B .ILOIN °:: D ION FILE C '-PY Permit No. Plar review approval is subject to errors and onions. not authothe Approvel of construction documents c • does the violation of any adopted approved Field • ' and cordons is acknowledged: By Data 3 i a City oaf Tu w EJILDM DrkriSION ELECTRICAL SYMBOL LEGEND SCALE: NONE Public Works, Building Division PERMIT NUMBER 0 8 0 4 RECEIVED CITY OF TUKWILA JAN 17 2008 PEHMI f CENTER FILE COPT ur/06I10 _( o7 T►° w 73-07129-03 W W CO re 0 C] n O v 0 0 0) 0) W n 0 O O A d N Q • l• m !mink uavoiI 1) -29-01 977 ID 1 I Jr' EXISTING FACP • NORDSTROM a C MM. MUM MUM 11111111100 1=11 MIMI 1 1 Flo a 0 it FI MOM ■IM EXISTING MAIN TELEPHON BOARD (QWEST) AND FIBER CABLE. a tl a R R 4C 'enr e ; a a 1 1 1 1 'NNW' °sr ,'err , , 'wry NNW rrs.411117; low 'rte' -w` ' - a L 1 a ler x ;;- iT 6TECL ii-L L Lai i 1111 1.�. J. i$.1 1 4 1 1 1 1 KEY NOTES: 0 PROVIDE 4" EMT C.O. FROM TELECOM ROOM TO POLICE SUB— STATION FOR TELEPHONE/DATA CONNECTIONS. PROVIDE INSULATED BUSHING ON CONDUIT ENDS AND PULL LINE IN CONDUIT WITH LABLIING BOTH ENDS. WHERE POSSIBLE, ROUTE CONDUIT A MINIMUM OF 9' AFF IN SERVICE CORRIDORS. WHERE CONDUIT CROSSES MALL CONCOURSE. COORDINATE EXACT CONDUIT ROUTING WITH OWNER AND OBTAIN OWNERS APPROVAL OF ALL PROPOSED ROUTING PRIOR TO INSTALLATION. COORDINATE MST SERVICE REQUIREMENTS WITH MICHAEL HARRISON, PHONE (866)416 -7613 OR EMAIL Michael.HarrisonCPgweskcom. GENERAL NOTES: 1. THE PURPOSE OF THIS DRAWING IS 10 SHOW GENERAL AREAS OF WORK AND LOCATIONS OF SOME EXISTING POWER DISTRIBUTION AND SYSTEMS EQUIPMENT. REVIEWED FOR CODE COMPLIANCE NPPA 70 - NEC FEB 282.0R Cif Of (* ila ILDING DWI ION B 13"a ELECTRICAL SITE PLAN NORTH SCALE: 1" = 50' -0" RECEIVED CITY OF TUKWILA JAN 1 7 2008 PERMIT CENTER w 73-07129-00 Al BLD'G DEPT. COMM. 11/26/2007 2 0 oe J 0 0.. 1 qp (E) LIGHTING CONTROL (E) PANEL HJA (E) PANEL LJC LOCATED IN AC PENTH USE #-3 (ROOF) (Fp 49 v 39 37 41 46 LEO j 50 L 39, 40 n77-'-----------'-lik 0 LHC -41, 2, 43, 44 4 LOCATED IN AC PENTHOUSE #4 (ROOF) LHC -49, 50, 51, 52 (E) LIGHTING CONTROL (E) PANEL HHA 122‘...----4-- (E) PANEL LHC � (E) PANEL WA c_ DEMOLITION AT MACY'S COURT POWER AND SYSTEMS PLAN NORTH SCALE: 1/8. = 1'-0" LEGEND NOTES GENERAL NOTES: 1. FLOOR OUTLETS SHOWN ON THIS PLAN ARE EXISI1NG TO REMAIN. nEWEPL�� E N FOR CODE PA o a NEC N FEB 2 S NOB City Of Tukwila BODIN •: OM .ION Emmet u it0 -► _07I LLI • t N N ® CAS O KEY PLAN INE L 0 0.2 .0= CD tum. a) w L ©2007, DLR Group inc., a Washington corporation, ALL RIGHTS RESERVED. BID/ CONSTRUCTION SET 10 -1 -2007 LEGEND NOTES KEY NOTES: 0 REMOVE WIRING DEVICES SHOWN IN THIS AREA. RE -USE EXISTING BACKBOXES AND CONDUITS FOR DEVICES SHOWN ON SHEET E1.3. 0 EXISTING °TPD° TELEPHONE OUTLET TO BE RELOCATED IN NEW POLICE SUB-STATION. SEE SHEET E1.3. COORDINATE EXACT LOCATION WITH OWNER. SEE SHEET E1.3. EXISTING SPEAKER TO BE RELOCATED IN NEW CEILING. u /ae/ee� 1. REMOVE EXISTING DISCONNECT AND ASSOCIATED CONDUITS AND WIRING BACK TO PANELBOARD OR LAST ACTIVE DEVICE TO REMAIN. GENERAL NOTES: BIM CONSTRUCTION SET 10 -1 -2007 1. REMOVE ALL BRANCH CIRCUIT WIRING AND CONDUITS ASSOCIATED VNTH ANY ELECTRICAL WIRING DEVICES AND OUTLETS AS PART OF DEMOLITION BACK TO PANEL BOARD OR LAST ACTIVE DEVICE TO REMAIN. EXISTING RESTROOM EXISTING RESTROOM EXISTING RESTROOM < 101) EXISTING OFFICE SPACE < 102 EXISTING BREAK ROOM <109> EXISTING OFFICE SPACE <10S>> EXISTING SECURITY OFFICE SPACE <103> EXISTING OFFICE SPACE < 104 >> EXISTING STORAGE ROO4 EXISTING STORAGE ROOM EXISTING ENERAL OFFICE 105> EXISTING STORAGE ROOM c EXISTING OFFICE SPACE <107> '_EMIT OF WORK EXISTING OFFICE SPACE <105> Z a (1) z 2 �O �Q O <uJ w O a� W 01- LLZ LL o —J ›- < E 2 W W � cn W O V O I-- w 0 o CD Ea RI MI la ENIENEMZEIRMEEKEMIESISIERMEZEEEENEMIE xFMENIEEEELE EMOMMEEMWEEMEAMMEEIMMESEEE31 73- 07129 -03 RECEIVED CITY OF TUKWILA JAN 17 2008 Pth MIT CENTER KEY PLAN 0 NOM !I1INE 540E01 DEMOLITION SECURITY OFFICE POWER AND SYSTEMS PLAN NORTH SCALE: 1/4" = 1' -0" o a-,03 (13 Architecture ©200T, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED. LHC-29,31 LEGEND NOTES DEMOLITION KEY NOTES: 10 REMOVE COLUMN LIGHTING INCLUDING (4) UPLIGHT FIXTURES 458W, 120V AND (4) DOWNLIGHT FIXTURES 62W, 120V. REUSE ELECTRICAL CIRCUITS FOR NEW LIGHTING FIXTURES. SEE NEW LIGHTING PLAN E2.1. 11/_10- t -67 J BID/ CONSTRUCTION SET 10 -1 -2007 LHC -1 ,161 IJIC -18 STING SS DESIGN LJC --9,11 EXISTING CARTON CARDS 65� 2808 SF EXISTING NATURALIZER 660 12855E EXISTING HELZGERG DIAMONDS <576> 1280 SF EXISTING THINGS REMEMBERED 1396 SF EXISTING FRANKLIN COVEY < 568 > 5052 SF (E) LIGHTING CONTROL (E) PANEL HJA (E) PANEL LC (EruGti IINC LAM ItaUL (E) PANEL LJB LOCATED IN AC PENTH i (ROOF) EXISTIN SHROUD COLUMN (TYPICAL OF 34) LOCATED IN AC PENTHOUSE #4 (ROOF) (E) LIGHTING CONTROL EXISTING LE CHATEL <58o> 571 SF (E) PANEL HHA (E) PANEL U-IC (E) PANEL LHA LHC -49,51 EXISTING STARBUCKS <584> 827 SF EXISTING THE PICTURE PEOPLE (672 2155 SF EXISTING SEATTLE MARNIERS TEAM SHOP <585> 1654 SF EXISD G M EXIS1ING w XISTIN el um!, -, ti CS . p N 6 ti Or EX?STINNG TRASH F.XISTINC, EXISTING LHC -32, RECEIVED CITY OF TUKWIL.A JAN 17 2008 PEfMI r CENTER EXISTNG ABERCROMBIE <675> 5064 SF EXISTING ACIFIC SUNWEAR 4097 SF KEY PLAN LHC -4 ,4' mun NMI 0 .17 a) ca.:2 CD Lrr DEMOLITION MACY'S COURT LIGHTING PLAN 0 Architecture Engineering ©2007, DLR Group Inc., a Washington corporation, ALL. RIGHTS RESERVED. 17 EXISTING CORRIDOR 19 EXISTING RESTROOM EXISTING RESTROOM <_ 101 11 335 EXISTING OFFICE SPACE EXISTING BREAK ROOM < 109 EXISTING SECURITY OFFICE SPACE EXISTING BA K OF HOUSE c EXISTING OFFICE SPACE <104> EXIST3NG STORAGE ROOM rffi MI;� Iwg 1 K EN EXISTING STORAGE ROOM EXISTING STORAGE ROOM 3 LIMIT OF WORK EfONNAMMENIERAMMEMEEININNEMINEEMINEMMIEIMIMMIMIISISMEREE MMINKINEMEGIIMMINENIMINNMEEMMMMUIRMLOI DEMOLITION SECURITY OFFICE LIGHTING PLAN NORTH SCALE: 1/4" = 1. -0" LEGEND NOTES KEY NOTES: O REMOVE ALL LIGHTING FIXTURES AND ASSOCIATED UGHTING SWITCHES IN THIS AREA. RELOCATE EXISTING LIGHTING FIXTURE TO ACCOMODATE NEW WALL LOCATION. SEE SHEET E2.Z • REMOVE EXISTING WALL MOUNTED TWO HEAD EMERGENCY LIGHT. GENERAL NOTES: 1. REMOVE ALL BRANCH CIRCUIT WIRING AND CONDUITS ASSOCIATED WITH ANY ELECTRICAL WRING DEVICES AND OUTLETS AS PART OF DEMOLITION BACK TO PANEL BOARD OR LAST ACTIVE DEVICE TO REMAIN. CODE. C� OP NEC, NfPN Eg 2 g 2p� City Of Tukw� �pN BUIWI% ® - RECEIVED CIT1 OF TUKWILA JAN 17 2008 PERMIT CENTER Z 0 I= QO aZ w z z � �O Ce w U z Fr. 0 J Q c7f 0 Li] W � u) zw V 51 I— w 0 D CO 'CC W 73-07129-03 NORDSTROM d KEY PLAN Group Architecture Engineering Planning Interiors ©2007, DLR Group Inc,, a Washington corporation, ALL RIGHTS RESERVED. BID/ CONSTRUCTION SET 10 -1 -2007 1- N ca Lu M I Cr, N �y o� I d= a0 0 N W co. - N • .11 MIN A� I\ERENE, i -J =off ■ ,I1 n 5.5 I 1 --r E3 14 LEGEND NOTES KEY NOTES: 0 PROVIDE (3) 20A /1P, 120V POWER CONNECTION FOR NEW NORDSTROM SIGN. 0 EXTEND 120V CIRCUIT UNDERSLAB FROM EXISTING DIRECTORY TO NEW FLOOR MOUNTED DIRECTORY LOCATION. PROVIDE STUB -UP 6" AFF AND J-BOX FOR ELECTRICAL CONNECTION TO NEW DIRECTORY, FBOIC. COORDIANTE EXACT LOCATION WITH OWNER AND ARCHITECT. a: 30 26 LKA- 26,28,30 • Fir- I DIRECTORY—'- DIRECTORY -- EXISTING DIRECTORY ---� • 0 111 PP- 3/4 "C: 2 '12, 1 #12G. 0 (E) PANEL LKA�_ (E) PANEL HKA AC PENTHOUSE #1 (ROOF) (E) LIGHTING CONTROL L rC REVXEWEp�ANCE �,pNFPA 70 NEC N� BUILDING o SION WEST ENTRY POWER PLAN NORTH SCALE: 1/8" = 1' -0" RECEIVED CITY OF TUKWILA + JAN 17 2008 PERMIT CENTER u/oo/*to - I - a7 Z O O ct z 0 a Em W w~ Z O J O. -I ›- < rI z w H z w w J 1- Q a 00 W cQ NORDSTROM 0 KEY PLAN 0 0 WARS mocyb .....I._ 12 co _ ... —n 1�� 0 o.p Q c c D o .o A �I INS! Wild; 'IIj IINI� MEI 1 SIO■ 0 a) Cam -cs)c—c a) O Lit Ce iii• U In :1.2 BID/ CONSTRUCTION SET 10 -1 -2007 LEGEND NOTES KEY NOTES: 0 EXISTING PFTITF T <124) EXISTING VERIZON WIRELESS <9018> EXISTING CUSTOMER SERVICE 0 0 PROVIDE 3/4° PVC SCHED. 40 CONDUIT WITH PULL STRING FOR FUTURE 100A, 120/208V 1 PH 3W POWER USING 3#3 THWN AND #80 CU. SEE E1.3 FOR SWITCHBOARD TMB -F1 LOCATION. SEE E3.2 ONE-UNE DIAGRAM FOR FUTURE CONNECTIONS TO THE NEW SWITCHBOARD SECTION. PROVIDE 3/4" PVC SCHED. 40 CONDUIT WITH PULL STRING FOR FUTURE TELEPHONE /DATA. SEE ES1.O FOR TELEPHONE BOARD LOCATION. PROVIDE 3/4° PVC SCHED. 40 CONDUIT WITH PULL STRING FOR SPRINKLER WATER FLOW ANNUNCIATION. FIELD VERIFY FIRE ALARM CONTROL PANEL LOCATION. Irannwhu/08/oIIO -IG -o7 PROVIDE THREE GANG CAST IRON SHALLOW FLOOR BOX EQUAL TO HUBBELL "B4314" FOR POWER, PHONE/DATA AND FIRE SPRINKLER ANNUN. WITH THREE 52425 BRASS COVERS. PROVIDE THREADED FITTINGS TO PVC SCHED. 40 CONDUIT AS REQUIRED. REFER TO ARCHITECTURAL DRAWING A1.2 FOR EXACT LOCATIONS. 0 PROVIDE FLUSH WALL J --BOX, SIZE AS REQUIRED, MOUNT AT 3 FEET AFF TO TOP (TYP.) 0 EXISTING SUNGLASS DESIGN <9013> EXISTING LEEDS 0 NEW DIRECTORY ----.-- 3/4 "C: 2#12, 1 f12G.0 EXISTING FRANKLIN COVEY <568> BID/ CONSTRUCTION SET 10 -1 -2007 EXTEND 120V CIRCUIT UNDERSLAB FROM NEAREST EXISTING POWER FLOOR BOX TG NEW FLOOR MOUNTED DIRECTORY LOCATION. PROVIDE STUB UP 6" AFF AND J -BOX FOR ELECTRICAL CONNECTION TO NEW SIGNAGE, FBOIC. COORDIANTE EXACT LOCATION WITH OWNER AND ARCHITECT. PROVIDE TWO GANG CAST IRON SHALLOW FLOOR BOX EQUAL TO HUBBELL "B4214" FOR PHONE /DATA AND FIRE SPRINKLER ANNUN. WITH TWO 52425 BRASS COVERS. PROVIDE THREADED FITTINGS TO PVC SCHED. 40 CONDUIT AS REQUIRED. REFER TO ARCHITECTURAL DRAWING A1.2 FOR EXACT LOCATIONS. PROVIDE ROUND CAST IRON FLOOR BOX EQUAL TO HUBBELL "B2506415" FOR POWER WITH S3525 BRASS COVERS. PROVIDE THREADED FITTINGS TO PVC SCHED. 40 CONDUIT AS REQUIRED. REFER TO ARCHITECTURAL DRAWING A1.2 FOR EXACT LOCATIONS. PROVIDE (2) 1 -1/2" PVC SCHED. 40 CONDUIT WITH PULL STRING FOR FUTURE 200A, 120/208V 1 PH 3W POWER USING 3 #1/0 THWN AND #4G CU. SEE E1.3 FOR SWITCHBOARD TMB -F1 LOCATION. SEE E3.2 ONE -LINE DIAGRAM FOR FUTURE CONNECTIONS TO THE NEW SWITCHBOARD SECTION. EXISIIN0 POWER FLOOR BOX GENERAL NOTES: 1. EXISTING CARTON CARDS <656> EXISTING NATURALUZER <660> EXISTING TALL'S AMERA <664> EXISTING FREIDL-- ANDER'S JEWELERS <668> ROUTE ALL CONDUITS IN EXISTING 3" MAX. DEPTH TOPPING SLAB. SEE SHEET S12. AT FLOOR BOX LOCATIONS, IF ADDITIONAL DEPTH I5 REQUIRED, CHIP OUT CONCRETE TO REQUIRED DEPTH. EXISTING HELZGERG DIAMONDS < 576 ) EXISTING THINGS REMEMBERED (E) LIGHTING CONTROL (E) PANEL HJA (E) PANEL LAC LOCATED IN AC PENTHG SE #3 (ROOF) (E) PANEL LJB 120/208V 1PH 3W POV R 2 PHONE/DATA PARTS FIRE SPRINKLER ANNUN. EVENT AREA LOCATION LOCATED IN AC PENTHOUSE #4 (ROOF) (E) LIGHTING CONTROL EXISTING LE CHATEL <580> (E) PANEL HHA EXISTI G JAMBA J ICE (E) PANEL LHC (E) PANEL LHA EW SECTION OF EXISTING R CENTER "T1.1B -F1° IN CORRIDOR EXISTING S T ARBUCKS TO EXISTING TTB IN CORRIDOR 3 € TO EXISTING FACP IN SECURITY OFFICE EXISTING THE PICTURE PEOPLE <672>i UP TO CEILING I 120/208V 1PH 3W POWER 2 PHONE /DATA PARTS FIRE SPRINK ANNUN. FUTURE KIOSK LOCATION <i 030if EXISTING SEATTLE MARNIERS TEAM SHOP <.558 > EXISTING EXISTING EXISTING TRASH EXISTING EXISTING 1 N ■ w RECEIVED CITY OF TUKWILA JAN 1 7 2008 PERMIT CENTER EXISTING ABERCROMBIE <W: EXISTING PACIFIC SUNWEAR <592> KEY PLAN 0 La. ,- 0 La C et Lu rn a ..„ z ,_ 0 . . a 0 CL CO o m 0 N c 120/208V 1PH 3W POWER 2 PHONE/DATA PORTS FIRE SPRINKLER ANNUN. FUTURE KIOSK I LOCATION IMO .I■ • •1... EXISTING "TMB –F1" METER CENTER 1200A, 208/120V, 30, 4W i ■ o- ls0,_.-_f•- •-•--•--- MMEIMM ■ ■ NEW SECTION TO EXISTING 'FMB –F1" METER CEN 3/4 "C – 3#.i, 1 #BG CU \19 EXISTING ■ CORRIDOR ■ E XSTING 100A, 208V/3PH, > P---EXISTING BOA_ 2 V/3PH. 7HP FUSED DISCONNECT 7,5HP FUSED DISCONECT EXISTING RESTROOM <110> 1 ■ ■ 1 OPANEL 'P' ■ I III II EXISTING RESTROOM EXISTING 100A 208V /3PH ELECTRICAL PANELBOARD EXISTING RESTROOM < 101 E JS11NG 100A, 208V /3PH ELECTRICAL PANELBOARD EXISTING OFFICE SPACE <.102->. Li EXISTING BREAK ROOM <109> EXISTING SECURITY OFFICE SPACE EXISTING BACK OF HOUSE 01h-111-11 P– 6,181= I11fWHlIIIIILFUI IIII IIIII11: I111111i] 6L1. I III IIIEfULILIIBI1 111111111fII111111111111 1 li _11 1_ 11 if10' di = � 1= P -13 1/20HP, 120V/1PH . Q5i I NEW LOCKER RM <104A> Le .. I' a s 11I1Ii1111 1111111lIIIII11 1ILIiiililti11iluiLl 1ilLEIL1:1 1kf111111' lliltlll {llLllll:lit[t111:lnELIILq Ii EXISTING STORAGE ROOM EXISTING STORAGE ROOM P- 3,5,7,9,11 EXISTING OFFICE SPACE <104> 1111111111) ll 1.1111111 t NEW GENERAL OFFICE <100r EXISTING STORAGE ROOM < / NEW OFFICE <107> NEW DISPATCH <105> NEW WAITING AREA 05A> IIt 111F111114.n t{I1 11111:11111.1 MINN NI IN IN MINN MIN POLICE SUB –STAT1 MALL SECURITY NEW POLICE SUB - STATION POWER AND SYSTEMS PLAN NORTH SCALE: 1/4" = 1' -0" LEGEND NOTES KEY NOTES: OPROVIDE 100A, 208V/1PH ELECTRICAL PANELBOARD 'P' CUTLER – HAMMER PRL1A. SEE PANEL SCHEDULE ON SHEET E4.1. ORELOCATE "TPD" TELEPHONE OUTLET. COORDINATE EXACT LOCATION WITH OWNER. v 0 EXISTING DEVICES TO REMAIN. EXISTING SPEAKER RE– INSTALLED IN NEW CEILING. RE –USE EXISTING BACKBOX AND CONDUIT FOR NEW DEVICES. OPROVIDE 4" EMT C.O. FROM TELECOM ROOM TO POLICE SUB – STATION FOR TELEPHONE /DATA CONNECTIONS. PROVIDE INSULATED BUSHING ON CONDUIT ENDS AND PULL UNE IN CONDUIT WITH LABELING BOTH ENDS. WHERE POSSIBLE, ROUTE CONDUIT A MINIMUM OF 9' AFF IN SERVICE CORRIDORS. WHERE CONDUIT CROSSES MALL CONCOURSE, COORDINATE EXACT CONDUIT ROUTING WITH OWNER AND OBTAIN OWNERS APPROVAL OF ALL PROPOSED ROUTING PRIOR TO INSTALLATION. COORDINATE QWEST SERVICE REQUIREMENTS WITH MICHAEL HARRISON, PHONE 866- 416 -7613 OR EMAIL MichaeLHarrison •west.com. 0 PROVIDE 120V POWER CONNECTION TO AUTOMATIC MOTION SENSOR. 8 PROVIDE NEMA 5-20R RECEPTACLE FOR WASHER. 9 PROVIDE NEMA 10-30R RECEPTACLE FOR DRYER. 10 PROVIDE SINGLE GANG COVER PLATE AND 4' SQUARE BACKBOX WITH SINGLE GANG MUD –RING FOR TELEPHONE /DATA OUTLET. PROVIDE 1" EMT C.O. TO ACCESSIBLE CEILING SPACE OR CABLE TRAY. PROVIDE INSULATED BUSHING ON CONDUIT END AND PULL UNE IN CONDUIT WITH LABELING BOTH ENDS. GENERAL NOTES: 1. DEVICES SHOWN HALF TONE ARE EXISTING TO REMAIN. NEW DEVICES ARE SHOWN FULL TONE. 2. CONNECT NEW FIRE ALARM DEVICES TO EXISTING FACP. -------\ R 00 FOR CODE A NF 70 - NEC City G DIVISION.... RECEIVED CITY OF TUKWILA JAN 1 7 2008 P thMII r CENTER 73- 07129 -03 A BLDG DEPT. COMM,11/26/2007 NORDSTROM n KEY PLAN MIN •1 P2 L 0 a) I1 O� co if•51.1 .1. ^a) W a) C21to L ©2007, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED. BID/ CONSTRUCTION SET 10 -1-2007 7 7 i u6 ' : Y r '7 i3q r: I i + 7 7 ,5140 OFF i 1 • V 7 V 7 r 7 ,ii42rF Lii 1F F r i r 7 i43+ 11 NEW DIRECTORY D1S11NG POWER FLOOR BOX L 1 NEW DIRECTORY -- 3/4 "C: #12, 1 #12G. 3/4 "C: #12, 1 #12G. L r s\ 44/ Lf :1 (E) LIGHTING CONTROL (E) PANEL HDA (E) PANEL LDA (E) LIGHTING CONTROL fll 7 r 7 7 i 7 \ 461' \46. ii l 7 ,r 1 l 5 f i 1 4 Y Y J -EK J. n NORTH ENTRY POWER AND SYSTEMS PLAN NORTH SCALE: 1 /8" M 1' -0" 7 LEGEND NOTES KEY NOTES: 0 EXTEND 120V CIRCUIT UNDERSLAB FROM NEAREST EXISTING POWER FLOOR BOX TO NEW FLOOR MOUNTED DIRECTORY LOCATION. PROVIDE STUB-UP 6" AFF AND J -BOX FOR ELECTRICAL CONNECTION TO NEW SIGNAGE, FBOIC. COORDIANTE EXACT LOCATION WITH OWNER AND ARCHITECT. REVIEWED FOR P1NANCE NF PA PA 7p e NEC FEB 282Q8 City Of 'Tukwila B I,pUN DM ION RECEIVED CITY OF TUKWILA JAN 17 2008 PERMIT CENTER liammitm/031/0 —1. 07 14: w KEY PLAN Group Architecture Engineering Planning Interiors P ©2007, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED, BID/ CONSTRUCTION SET 10 -1-2007 LEGEND NOTES KEY NOTES: EXTEND 120V CIRCUIT UNDERSLAB FROM EXISTING DIRECTORY TO NEW FLOOR MOUNTED DIRECTORY LOCATION. PROVIDE STUB-UP 6° AFF AND J --BOX FOR ELECTRICAL CONNECTION TO NEW DIRECTORY, FBOIC. COORDIANTE EXACT LOCATION WITH OWNER AND ARCHITECT. LOCATED IN AC PENTHOUSE I (ROOF) (E) PANEL LDB (E) LIGHTING CONTROL (E) PANEL HDB (E) LIGHTING CONTROL z 0 0 z w 0 z W O. I- O Q a ;z < LLJ w Q= Lt Q O a cn L m c O ti NEW DIRECTORY 150W, 120V /1PH 3/4'C: 2 #12, 1 #12G. 01 EXISTING DIRECTORY RECEIVED CITY OF TUKWILA JAN 17 2003 PERMIT CENTER KEY PLAN EAST ENTRY AND JCPENNEY POWER AND SYSTEMS PLAN NORTH SCALE: 1/8' 0 U Architecture Engineering @M OT, DLR Group inc„ a Washington corporation, ALL RIGHTS RESERVED. f LEGEND NOTES KEY NOTES: EXTEND 120V CIRCUIT UNDERSLAB FROM EXISTING DIRECTORY TO NEW FLOOR MOUNTED DIRECTORY LOCATION. PROVIDE STUB -UP 6" AFF AND J--BOX FOR ELECTRICAL CONNECTION TO NEW DIRECTORY, FBOIC. COORDIANTE EXACT LOCATION WITH OWNER AND ARCHITECT. RE -USE EXISTING FLOOR BOXES FOR POWER AND DATA OUTLETS FOR KIDS PLATE TENANT. PLUM hies nella - < —or BID/ CONSTRUCTION SET 10 -1-2007 NEW DIRECTORY 150W, 120V/1PH EXISTING DIRECTORY 91jpCE CO NITA 70 - NEC FEB 2, 8 20 City Of Tukwila BUILDING DIVISION co. w RECEIVED CITY OF TUKWILA JAN 17 2008 PLI MI T GETTER KEY PLAN NM :at MN •1U a G O G a C G d U rn N U1 L ▪ l W cp ° • o c▪ � rn Q N G cJ L▪ .0 0 2 O . 21 O PARTIAL SOUTHWEST MALL POWER PLAN NORTH SCALE: 1/8" = 1'--0" 0 0 cm. 2 0 rze J 0 c W 0 © 2007, DLR Group inc., a Washington corporation, ALL RIGHTS RESERVED. EXISTING PF'T1 T FT EXISTING VERIZON VORELESS K9018>> LEGEND NOTES GENERAL NOTES: 1. REFER TO ARCHITECTURAL ELEVATIONS AND SECTIONS FOR EXACT FIXTURE LOCATION AND MOUNTING HEIGHT. 2. SEE LIGHTING FIXTURE SCHEDULE ON SHEET E4.1. 3. PROVIDE 1/2" FLEXIBLE METALLIC TUBING FOR ELECTRICAL WIRING BETWEEN EXISTING COLUMN J--BOX AND NEW LIGHTING FIXTURE. RUN CONDUIT INSIDE STEEL CHANNEL RING. SEE ARCHITECTURAL DETAILS 20/A3.0, 22/A3.0, AND 31/A3.0. - u/(to -q —o7 Provide an average of one foot- candle illumination at the floor along the entire egress pathway and exit discharge BID/ CONSTRUCTION SET 10 -1 -2007 LJC 18, 01 LHC -2, STING SUNG S DESIGN EXISTING LEEDS < > C41012 LHC *2123 EXISTING CARTON CARDS 658> EXISTING NAIURALIZER <660> _ EXISTING_ iALL'S AMERA < 664 EXISTING FREIDL— ANDER'S JEWELERS <666> EXISTING HELZGERG DIAMONDS < 576 j EXISTING THINGS REMEMBERED (E) LIGHTING CONTROL (E) PANEL HJA (E) PANEL LJC (ErT IGIi I ING LON I I OL (E) PANEL LJB LOCATED IN AC PENTHISE #3 (ROOF) LOCATED IN AC PENTHOUSE #4 (ROOF) (E) LIGHTING CONTROL LHC , 41,43 EXISTING LE CHATEL <580> (E) PANEL HHA EXISTING JAMDA J ICE <670 (E) PANEL LHC (E) PANEL LHA EXISTING THE PICTURE PE RETIE-WED COMPLIANCE CE CONFPA 70 - NEC FEB 2 ?8208 City Of Tukwila BUILDING DIVISION EXISTIN SEATTLE MARNIERS TEAM SHOP 588 • t1! w RECEIVED CITY OF TUKWILA JAN 17 2008 PI_HMIT CENTER EXISTING ABERCROMBIE <676> KEY PLAN i N w C < M o I N E I18 o U3 C7 U " N c � O -""t", O MACY'S COURT LIGHTING PLAN NORTH SCALE: 1/8" a Es) - _ = es 2 .,,. ... CO Iv c co C Lu Ce N a) irti:1., U N 3= L ®2007, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED. l EXISTING CORRIDOR EXISTING 140A, 2GV /3PH, 3OHP FUSED DISCONNECT EXISTING 100A, 20BV /3PH ELECTRICAL PANELBOARD EXISTING RESTROOM EXISTING EOA, 208V /3PH, 7.5HP FUSED DISCONNECT EXISTING RESTROOM < 111. > EXISTING RESTROOM .(101 PANEL EXISTING 100A, 208V /3PH c ECTRICAL PANELBOARD '2' ESTiNG OFFICE SPACE 10?' BREAK ROOM EXISTING SECURITY OFFICE SPACE 103 TO EXIS1ING CKT I - K OF HOUSE EXISTING STORAGE ROOM EXISTING STORAGE ROOM rIMI1111111111111!0 = =it EXISTING OFFICE SPACE <1D4 RF -1 X1 TO EXIS11NG CKT EXISTING STORAGE ROOM EXISTING STORAGE ROOM Mo�■rn�a�������s��a ® MUM IMMIIIMIN I■ INMMIN■aN■■a�■r�IrNM■■®- IM NEW POLICE SUB - STATION LIGHTING PLAN NORTH SCALE: 1/4" = 1' -0" LEGEND NOTES KEY NOTES: 1 RELOCATE EXISTING LIGHTING FIXTURE. 2 PROVIDE LIGHT SWITCH TO CONTROL RELOCATED FIXTURE. 0 PROVIDE OCCUPANCY SENSOR WALL SWITCH EQUAL TO LEVITON ODS10 -W SERIES. 0 PROVIDE "'TIME DELAY OFE',, LIGHT;SWITCH EQUAL TO LEVITON 6515M -I TO CONTROL NEW LIGHTING FIXTURE AND EXHAUST FAN IN BATHROOM.' t. PROVIDE UNSWITCHED HOT LEAD AND NEUTRAL TO EXIT SIGN. PROVIDE 3 -WAY SWITCH BY NEW DOOR TO CONTROL NEW LIGHTING FIXTURES. I!; GENERAL NOTES: 1. DEVICES SHOWN HALF TONE ARE EXISTING TO REMAIN. NEW DEVICES ARE SHOWN FULL TONE. 2. SEE LIGHTING FIXTURE SCHEDULE ON SHEET E4.1. 3. LIGHTING FIXTURES WITH EMERGENCY BATTERY PACKS REQUIRE THE HOT UNSWITCHED CIRCUIT CONNECTION, WIRE COUNT HASH MARKS ARE NOT SHOWN FOR THIS. E IE E FOR CODE COMPLIANCE NFPP' 70 o NEC fE.B` ?82 City ui SION AWING D B RECEIVED CITY OF TUKWILA JAN 1 7 2008 Pthlvu I CENTER Z 0 0 zZ gW o Z_ uj 0 1- J O J � J H 1 w 1-wim 0 m W � Z W — 0 a H w0 z cA eq LU 73- 07129 -03 C) 0 ABLD'G DEPT. COMM. 11/26/2007 NOROSIROM J KEY PLAN MINN A1• m 0 c a CD C w w 2 L. co cr) W 0 .1 Ce L o „V W 0 :.=. L ©200T, OLR Group inc., a Washington corporation, ALL RIGHTS RESERVED. BID! CONSTRUCTION SET 10 -1 -2007 -r,7- -ITII In cn IQ co b < b E M1c) (q O vN 00 O N rPENTHOUSE #4 PANEL LHA 208Y/120V 30, 4W 225A SECTION 1 PANEL LHA 205Y/120V 30, 4W 225A SECTION 2 Ar 75KVA 480V i1t' 208Y/120V 3 %% G 4W PANEL HHA 480'Y/277 V 30, 4W 600A --] 1 A.C. PENTHOUSE #3 PANEL LHC 208Y/120V 34, 4W 225A SECTION 1 PANEL LHC 208Y/120V 34, 4W 225A SECTION 2 75KVA 480V I 205Y/120V a%% C 4W [PANEL WEE PANEL LJ3 I208Y/120V 208Y/120V 30, 4W 30, 4W 225A 225A I SECTION 1 SECTION 2 rr�Y� 45KVA 480V 208Y/120V 3 %% C 4W PANEL L,JC 208Y/120V 30, 4W 225A Lkj I 45KVA 480V 2a0q/�Ba�)Y/120V 37Z c 4W PANEL HJB 180Y/277V 30, 4W 400A L VOLTAGE REGULATOR FA.C. PEN THOU SE i6 PANEL LDA 208Y/120V 3-0, 48 225A SECPON 1 PANEL LOA 208Y/120V 30, 48 225A SECTION 2 75KVA 450V to 208Y /120V 37Z C 48 PANEL HDA 480Y/277V 30, 4W 400A VOLTAGE EGULATOR FA.C. PENTHOUSE '15 PANEL LNG 208Y/120V 30, 4W 225A SECTION 1 PANEL LHB 208Y/120V 34, 48 225A SECTION 2 45KVA 450V `1' 1 208Y/120V 3%% C 48 PANEL HH8 480Y/277V 30, 4W 225A A.G. PENTHOUSE #7 PANEL L DBIPANEL LDB 208Y/120V 208Y/120V 3C. 48 30, 48 225A I 225A SECTION 1i SECTION 2 PANEL HOB 80Y/277 34, 44 400A PANEL LBO3 205Y /120V 30, 48 100A 75KVA 460V 208Y/120V 3Z% C 4W PANEL HDB2 480Y/277V 30, 48 225A VOLTAGE REGULATOR F.C. PENTHOUSE #2 PANEL LJA PANEL LJA 208Y/120V 208Y/120V 3fb, 4W 30, 4W 225A 225A SECTION 1 SECTION 2 LULU 45KVA 480V 3%% C 2 3€C 4W PANEL HJA VOLTAGE 480Y/277V REGULATOR 30, 48 400A L J r4.0. PENTHOUSE f1 PANEL LKA PANEL LKA 205Y/120V 208Y/120V 30,4W 30,4W 225A 225A SECTION 1 SECTION 2 PANEL HKA 480Y/277V 3+D, 48 400A 45KVA 480V 208Y/120V 37A C 48 VOLTAGE REGULATOR 1 MALL LEVEL PSE PAD MOUNTED TRANSFCfMER BB2927 (V13) 1000 KVA 480/277V, 30, 4W X/I? =8 5.3% 22,600A SYMM ASCI 1 i TO PSE VAULTS V10 AND V12 (4)4=C: 4 #600XCMIL CU OR (5)4*C: 4#750KCMIL AL TLIMEL EL EL J 0 F L Lf} MAIN SWITCHBOARD, 480Y/277V, 30, 4W, 2000A, 100K MC tJ7 ..J 0 J 0 O PANEL PA 48OY/277V 30, 4W 400A PANEL LHD PANEL LHD 480Y/277V 480Y/277V 30, 4W 30, 48 225A 225A SECTION I KCTICN2 J J J EL 4 i 157 16? O in ic7 0 in I- r 1 f- Q 1 Is LA LA „� cry C� o- �'7 LJ N) EJ? "'T 4} '-) W 7 1"7 w in ! Q D c cp d O C'i I a -4- 1,446'G: 4 #50OKCMIL CU CR (5)6 "C: 4f750KCMIL AL LOADING COCK VAULT V66 75KVA 4I OV 2D8Y /12DV 3%% C 4W PANEL PB 4-80Y/277V 30, 48 225A MALL LEVEL EXISTING LANDLORD POWER DISTRIBUTION SCALE: NONE LEGEND NOTES KEY NOTES: 1 EXISTING GE PANEL AFFECTED BY THIS PROJECT. 2 LOAD REDUCED AFTER DEMOLITION. REVIEWED FOR CODE COMPLIANCE NFPi► 70 - NEC FEB 28 T0u (af Yu{ila B.lLD1NG D .. ION RECEIVED CITY OF TUKWII.A JAN 1 7 2008 PtRivu f CENTER Z O 17- O z °LU Immm. m E2O 1(7) E 1-ll w ? O J Q 0 2 � W 1- Z z gw 0U z= x 0 W fA ▪ 1~ M 0 C N W O CI a 0 U 0 Architecture Engineering ©2UQT, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED. r 200 AF SPACE SWBD TIRE -J4 208Y/120V, 30, 4W, 12COA, 65:AIC RS` PAD MOUNTED TRANSFORMER BB28.90r (V11) 500 KVA 2D /120V, 30. 4'N TO PSE VAULTS V1oo AND V12 (6)4 "C; 4 #25OKCMIL (4)4"C: 3 #SODKCMIL, :#3 /0 Kj• -• (4)4"G: 3 #500KCMIL, 1#25OKCMI.. (N) = 8 %Z = 2.3% 60,30 DA SYM M AASCI TUNNEL (6) 4 #25OKCMIL VIA (2)6"C (4) 3 #500KCMIL; e #3 /OKCFI L (N) 'OA (2)6"C (4) 3 #5O0KCMIL , 1 #3 /C<CMIL (ti) VIA (2)6 "C -e BUS GUTTER SWIBD TSC —J3 208Y/120V, 30, 4W, 1000A, 50KAIC E 30, 1#8G CU SPARE SPARE N N I SECTION 3 3/4 "C POLICE SUB- STATION (2)1 -1 /2 "C (2)1-1/2 "C NT AREA LOCATION RE KIOSK LOCATION 1030 620 — VERIZON TIRELESS 648 — GYMBOREE 48,908A O 0 0 644 — BATH d A 4 0 N 0 t� a LN N N N SECTION 2 SECTION 1 I 0 9 684 — POLICE STA110 J KEY NOTES: SWITCHBOARD AFFECTED BY THIS PROJECT. PROVIDE NEW SECTION 3 ATTACHED TO EXISTING CUTTER- HAMMER METER CENTER 1MB -F1. AMP RATING AND KAIC RATING FOR NEW SECTION TO MATCH EXISTING RATING OF TMB -F1. PROVIDE CLASS T FUSE FOR NEW TENANT. 4 COORDINATE WITH UTILITY EXACT METERING REQUIREMENTS. 5 FUTURE CI..ASS T FUSES TO BE PROVIDED AND INSTALLED BY TENANT E.C. ABANDONED GENERAL NOTES: 1. EXISTING ELECTRICAL SHOWN LIGHT IJNE. NEW ELECTRICAL SHOWN BOLD. REVIEWED OIypp,NCE tr.____v____ NFPA 70 - NEC FEB 2 8 2408 City Of TLIIMIla B CODE COMPLIANCE. D SION HOUSE PANEL F1 (UTIIJTY CORRIDOR) SW!BD ThIB —r1 208Y/120V, 0, 4W, 1200A, 651(.41C EXISTING WEST TENANT POWER DISTRIBUTION ONE -LINE DIAGRAM SCALE: NONE ..J c� 0 w z J Z w0 O ~ zj O p 1:7 = m W h D LL W W O z a Z J Q z W ~ w W (-) Z= X � W fn CITY OF TUKW, tA JAN 17 2008 PERM) i CENTER 0 1 C.Lc2c Lims c.) 0 co 0 Architecture Engineering ©2007, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED. BID/ CONSTRUCTION SET 10 -1 -2007 LIGHTING FIXTURE SCHEDULE Project Name: SOUTHCENTER MALL RENOVATIONS MFR. CATALOG NUMBER LAMP BALLAST FIXTURE DESCRIPTION Project No: 73-07129-03 RF -1 FOCAL POINT FLU- 22-B-- 2- BX40 -S- 120- G- PS- FW- L835 --W11 -EM WHERE INDICATED ON DRAWINGS RF -2 FOCAL POINT FLU- 24- B- 2T5 -S- 120- G- PS -FW- L835 -WH -EM WHERE INDICATED ON DRAWINGS SF -1 TERON EAGLE EE213QE WF -1 VISA LIGHTING CB6542- 2FS54- FINISH TO BE SELECTED TO MATCH EXPANSION -120 TYPE F F F F QTY 2 2 2 2 WATT DESCR BX40 35K FP28 35K T5 CF1300/E/835 13W QE 35K FP54 T5 -HO 35K TYPE E, OT VOLT 120 277 INPUT WATT E X 76 E x 60 E x 26 E 108 MOUNTING RECESSED RECESSED SURFACE COLUMN WALL MOUNT TYPE 2'X2' 2'X4' 10" DIA DNLT 96" DESCRIPTION RECESSED DIRECT /INDIRECT BASKET TYPE FIXTURE WITH PERFORATED CENTER BASKET; 5" DEEP; SHADED FIXTURES TO BE PROVIDED WITH EMERGENCY BATTERY PACK. 120V PROGRAM START BALLAST; UL LISTED. RECESSED DIRECT /INDIRECT BASKET TYPE FIXTURE WITH PERFORATED CENTER BASKET; 5" DEEP; SHADED FIXTURES TO BE PROVIDED WITH EMERGENCY BATTERY PACK. 120V PROGRAM START BALLAST; UL LISTED. 10" DIAMETER SURFACE MOUNTED FLUORESCENT FIXTURE. UL USTED FOR DAMP LOCATIONS. SURFACE MOUNTED UNEAR FLUORESCENT SCONCE NOTE X1 EMERGI -UTE PRESCOLITE SURE-LITES UTHONIA ESCORT EC SERIES PEX SERIES CLX SERIES GENERAL NOTES: LQM SERIES LED N/A LED A. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE UNITS MEETING FIXTURE SCHEDULE DESCRIPTION AND SPECIFICATION REQUIREMENTS. THE FIXTURE CATALOG NUMBER MAY NOT BE COMPLETE; USE ONLY AS A GUIDELINE B. FLUORESCENT LAMP BALLAST SHALL BE ELECTRIC, ENERGY - EFFICIENT, HIGH -POWER FACTOR, WITH MINIMUM OPERATING FREQ. OF 20,000 HZ. MANUFACTURERS: EBT, ADVANCE, MAGNETEK, KINGTEC, OR APPROVED EQUAL ABBREVIATIONS: F: FLUORESCENT L: LED(LIGHT EMITTING DIODE) E: ELECTRONIC, HIGH FREQUENCY BALLAST OT: OTHER(REFER TO FIXTURE DESCRIPTION) MT: MOUNTING S: SURFACE R: RECESSED W: WALL OT X 5 UNIVERSAL LIGHTING FIXTURE SCHEDULE SINGLE FACE EXIT SINGLE FACE GREEN LED EXIT SIGN. THERMOPLASTIC CONSTRUCTION. UNIVERSAL MOUNT. LETTERS SHALL BE EVENLY ILLUMINATED BY LED LAMPS TO CREATE GREEN LETTERS. EXIT SIGN SHALL BE UL LISTED. PANEL SCHEDULE PANEL P AMP MAIN BRKR: LOCATION: Police Sub - station AMP MLO: 100 VOLTS: AIC: CIRCUIT DESCRIPTION LOAD VA _ CKT BKR P CIR # LIGHTING - RM 104A, 106, 107, 108 858 20 1 1 COMPUTER - OFFICE 106 . 900 20 1 3 COMPUTER - OFFICE 106 900 20 1 5 COMPUTER - OFFICE 107 630 20 1 7 COMPUTER - OFFICE 107 900 20 1 9 RECEPT - RESTROOM 108, OFFICE 106 360 20 1 11 AUTO SENSOR - RESTROOM 108 200 20 1 13 ELECTIRC WATER HEATER - BACK OF HOUSE 2500 30 1 15 WASHER - BACK OF HOUSE 1200 20 1 17 _ Z 02779785 LOAD SUMMARY: CONNECTED FEEDER / SERVICE CALCULATION LIGHTING 0.86 KVA 1.07 KVA (125 %) LARGEST MOTOR 0.00 KVA 0.00 KVA (125 %) MOTORS 0.00 KVA 0.00 KVA (100 %) RECEPT 0.36 KVA 0.36 KVA (10KVA © 100 %, REMAIN © 50 %) KITCHEN EQUIPMENT 0.00 KVA 0.00 KVA (65 %) ELECTRONIC LOADS 3.53 KVA 3.53 KVA (100) ELECTRIC HEATING 2.50 KVA 2.50 KVA (100 %) MISC. 5.70 KVA 5.70 KVA (100 %) TOTALS 13 KVA 13 KVA 62 AMPS 63 AMPS 208/1ph/3w NOTES: Dec -06 1. NEW PANEL. 2. 3. 4. 5. 6. SWBD TMB -F1 208/120V, 3P, 4W, 1200A, 65KAIC LOAD DESCRIPTION METER DEMAND KWH DEMAND KW VOLTAGE 2006 -2007 PEAK MONTH EXISTING SECTION 1 SPARE 4 1 20 30 SPARE 6 Z 64554251 192.6 16.1 208/1ph/3w 8 Jul -06 20 Z 76459256 357.7 29.8 208 /1ph /3w 20 Aug -06 SPARE Z 06621174 109.7 9.1 208/1ph/3w SPARE May -06 1 Z 76349010 127.6 10.6 208/1 ph /3w 2 Jan -07 2250 Z 04533549 0 0.0 208 /1ph /3w 2250 abandoned Z 02779785 273.7 22.8 208/1ph/3w Dec -06 EXISTING SECTION 2 Z 29127282 195.8 16.3 208/1ph/3w Jul-06 Z 70190577 78 6.5 208/1ph/3w Aug -06 Z 64717202 134 11.2 208/1ph/3w Nov -06 Z 62685554 226.6 18.9 208/1ph/3w Jul-06 2 06498400 135.8 11.3 208 /1ph /3w Nov -06 Z 64-881974 346.8 28.9 208/1ph/3w Jul-06 Sub -total Section 1 +2 (Existing) 181.5 503.9 AMP DEMAND NEW SECTION 3 New kiosk #1 33.28 208/1ph/3w New kiosk #2 33.28 208/1ph/3w New kiosk #3 16.64 208/1ph/3w New Panel P 13.0 208/1ph/3w Sub-total Section 3 (New) 96.2 TOTAL (1.25xExisting + New) 323.1 896.9 AMP DEMAND LOAD SUMMARY FOR SWITCHBOARD TMB -F1 P A B A B A B A B A 208 Y/ 120 22,000 PH: 1 -Phase MOUNT: FLUSH W: 3 -Wire FED FROM: TMB -F1 CIR # P CKT BKR LOAD KVA CIRCUIT DESCRIPTION 2 1 20 NOTE 1 SPARE 4 1 20 30 SPARE 6 1 20 SPARE 8 1 20 SPARE 10 1 20 SPARE 12 1 20 SPARE 14 1 20 SPARE 16 2 30 2250 DRYER - BACK OF HOUSE 18 -- --- 2250 --- V5.2 BRANCH CIRCUIT SUMMARY PANEL LKA CKT DESCRIPTION NEW LOAD [W] REMOVED LOAD [W] 26 NORDSTROM SIGN 1,920 NOTE 1 28 NORDSTROM SIGN 1,920 NOTE 1 30 NORDSTROM SIGN 1,920 NOTE 1 NOTES: 1. EXISTING SPARE BREAKER 20A, 120V TO BE RE -USED FOR NEW LOAD AS SHOWN. BRANCH CIRCUIT SUMMARY PANEL LHC CKT DESCRIPTION NEW LOAD [W] REMOVED LOAD [W] REMOVED LOAD [W] LTG. COLUMN 216 2080 2080 TOTAL OF 25 COL. 5,400 52,000 BRANCH CIRCUIT SUMMARY PANEL LJC CKT DESCRIPTION NEW LOAD [W] REMOVED LOAD [W] LTG. COLUMN 216 2080 TOTAL OF 9 COL 1,944 18,720 CODE. 70 .. NEC :E328la City Of Tvllla CITY OF TIuKWILA JAN 17 2008 PERMIT CENTER 1 C.,,,---4--,„,,,,,, ' r \ 0\•-• 0 v N' BID/ CONSTRUCTION S 10 -1 -2007 ■ ;ti N p r � ▪ A r co O 0 0 Architecture Engineering ©2007, DLR Group Inc., a Washington corporation, ALL RIGHTS RESERVED.