HomeMy WebLinkAboutPermit EL08-0094 - SOUND TRANSITSOUND TRANSIT
4522 S 133 ST
ELO8-094
CRAM' Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206- 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 2613200006
Address: 4522 S 133 ST TUKW
Suite No:
ELECTRICAL PERMIT
Permit Number: EL08 -094
Issue Date: 04/08/2008
Permit Expires On: 10/05/2008
Tenant:
Name: SOUND TRANSIT
Address: 4522 S 133 ST , TUKWILA WA
Owner:
Name: SHEEHAN PAUL E Phone:
Address: PO BOX 68726 , TUKWILA WA
Contact Person:
Name: MICHAEL A BELLO Phone: 206 762 -7684
Address: 6533 3 AV S , SEATTLE WA
Contractor:
Name: L K COMSTOCK & CO INC Phone: 212 - 502 -7900
Address: 5 PENN PLAZA 12TH FLOOR , NEW YORK NY
Contractor License No: LKCOMCI312CR Expiration Date: 06/17/2008
DESCRIPTION OF WORK:
SET AND ENERGIZE SIGNAL BUNGALOW AT 133 ST
Value of Electrical: $5,000.00 Fees Collected: $205.00
Type of Fire Protection: National Electrical Code Edition: 2005
Electrical Service provided by: SEATTLE CITY LIGHT
Permit Center Authorized Signature:
Date: t—'"l!'o
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this electrical permit.
Signature:
ay,
Print Name: AW/ J' A L
Date: �C /G.f
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -094 Printed: 04 -08 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 2613200006
Address: 4522 5 133 ST TUKW
Suite No:
Tenant: SOUND TRANSIT
PERMIT CONDITIONS
Permit Number: EL08 -094
Status: ISSUED
Applied Date: 01/30/2008
Issue Date: 04/08/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Signature: �° �`"� Date:
��GP /oc
Print Name: ,4 //DDS 7 Ef'44%,4 ■I/e
doc: Cond -Elec
EL08 -094 Printed: 04 -08 -2008
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.:
Site Address: 4522 S. /33RD s'T. TQ 4 W /C,A WA 98/68 Suite Number: Floor:
Tenant Name: .90GOVD TiCAMS/ C /T New Tenant: ❑ Yes ❑ ..No
Property Owners Name: SOUND TRANS /T
Mailing Address: *0/ 30(47# v'ACI Po,V `97; c,S'EATTL E WA 93/64
11222 L) CC z.zl
Name: /0/CNAE[.. A . 8EL LC)
Mailing Address: 6533 3R.D AVEN'WE SOuTN/
1416el/o r ii /worA.s , c0
E -Mail Address:
Day Telephone: (2 O 6> 76 2-76 8¢
SGAT`TG ' 98/08
City State Zip
Fax Number: ( 2 0G,) 76 2 - 76 95
Company Name: L . / . COMS7OCk ' CO /NC
Mailing Address: S PENN PGA eA 1 / 2 T,4 FL oOR It/E'Ge) YO, e
Contact Person: M /CHA EL f{ . 16 EC-(.0
E -Mail Address: 14,76e/ /o @ seal/we) rks . Cowl Fax Number: (20 (o) 76 2 - 7695
Contractor Registration Number:
EC() / 1..00/1/1 CI3 /2 C Expiration Date: DG // 7/0 i@ 8
City
Day Telephone: (20 Co) 76 2 - 76,Q
N Y /000/
State Zip
Valuation of Project (contractor's bid price): $ $j 000
Scope of Work (please provide detailed information): SET AND NE' G% E S /,(yNA ,BU,(IGA LOW
Ar
Will service be altered? ❑ Yes Q(No
Type of Use:
Type of work:
B' New El Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement
❑ Low Voltage ❑ Generator El Fire Alarm [V]rTelecommunication
❑ Temporary Service
Adding more than 50 amps? ❑ Yes ❑ No
Property Served by:
❑ Puget Sound Energy
Rif Seattle City Light
H: ApplicationsWonns- Applications On fine4-2007 - Electrical Permit Application.doc
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $55.00 ea
1ESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
Value of Construction -- In all cases, a value of constriction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
M /CHAes�C_ .4 . £ EGGU
Day Telephone:
Mailing Address: 6533 340 AVE SOUTH SEATTG6
IDate Application Accepted:
City
Date: //30/08
( 2 0 6 ) 7 6 2 — 7 6 6 ' 0
WA( 980 /8
State Zip
Staff' Initials:
Date Application Expires: N.. 101,..d.23
H: ApplicationsWonns- Applications On Line\4 -2007 - Electrical Permit it Applcation.dac
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
Parcel No.: 2613200006
Address: 4522 S 133 ST TUKW
Suite No:
Applicant: SOUND TRANSIT
RECEIPT
Permit Number: EL08 -094
Status: APPROVED
Applied Date: 01/30/2008
Issue Date:
Receipt No.: R08 -01077
Payment Amount: $164.00
Initials: WER Payment Date: 04/08/2008 01:24 PM
User ID: 1655 Balance: $0.00
Payee: L K COMSYOCK
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 118900 164.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 164.00
Total: $164.00
don. Raraint -08
Printpd 04- n8 -200R
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: htv/Iwww.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -00260
Initials: JEM
User ID: 1165
Payee: MICHAEL BELLO
Payment Date: 01/30/2008
Total Payment: 123.00
SET ID: 0130 SET NAME: SOUND TRANSIT
SET TRANSACTIONS:
Set Member Amount
EL08 -093 41.00
EL08 -094 41.00
EL08 -095 41.00
TOTAL: 123.00
TRANSACTION LIST:
Type Method Description Amount
Payment Cash 123.00
TOTAL: 123.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.0 123.00
TOTAL: 123.00
7789 01/30 9710 TOTAL 123.00
Doc: RECSETS -OR
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
PERMIT NO.
Pr 'ect:
ow) T.1),AjS •• 7-
Type of Inspection:
,,, /
Aide s:
L� -�
-, _ /.+1l ,. --
/ .,
Date Called:
Special Instructions:
Date Wanted:
/��`
S V
p.m.
Requester:
Phone No:
A • • roved per applicable codes. 11 Corrections required prior to approval. f.
COMMENTS:
•
ft' /% /7 fJ0 04/ /
Inspecto `�,t` yo
Date://,
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
P.vaAM4f r..w YleE` •L ea. J awl' -1 LAN. mi:xsi_: b
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
latc-ogy
PER NO.
(206)431 -3670
Project:
Type of Inspection:
A dr ss:
2 ,C ,71Ra c
Date Called:
Special Instructions:
Date Wanted:
, I J,�
/g� //
a.m.
p.m.
Requester:
Phone No:
AO oved per applicable codes. Ei Corrections required prior to approval.
COMMENTS:
wv/c.e. SX•ve
\'*1 Ay416110W
Insp
GL &TfvMk'/1
Date: y46 /a
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT O.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Prooject:
``w,& -�s ` /-r
ri C---/(■__ .c
Type of Insp Pci n:
14. <E 1 �cyn i F
Address:
12 g p
112- ,5 1...-.._.7
t
...)1
Date Called:
c_zu //e/ .
Special Instructions:
Date Wanted��
a.m.
p.m.
Requester:
Phone No:
❑ Approved per applicable codes.
rrections required prior to approval.
COMMENTS:
ri C---/(■__ .c
IMOY/Y
14. <E 1 �cyn i F
r bite rh % /Wman li 2I(4 /Jo r
Rc. L, r' , /V- ze-A ,'zed f /GM
c_zu //e/ .
Inspect
//G
Date` /r /ir(
❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
9162299677
GE Transportation
Department of Labor and Industries
Factory Assembled Structures
POBox44430
Olympia WA 98504-4430
ONE,PERMIT PER FLOOR
08:01:08 a. m. 03 -11 -2008 3 /4
FACTORY PERMIT
Do not complete shadkd area
Permit 71177
Manufacturer No
Contact Phone
Manufacturer, Phone
Address City
_24 Q;L
Please check the appropriate box indicating the type of floor (unit) t) t be inspected
model
number and plan approval number in the spaces provided.
❑ Commercial Coach
Factory Built Structures
Temporary Worker Housing
Vendor/ Medical Units
F;44-
7$J -Z3? ' r1
State Zip
�S hMi
and list the serial number,
Serial No.
Model No.
Plan Approval Number
DRFA' b?OQO ?Z_
L&I Department Use Only
FLOOR
r
COVER
J t7
INSULATION
/ '
VAPOR BARRIER
FINAL
L.
Date
u
Date
7 -v?
Date
• /
•
Invoice #
Invoice #
1
Invoice #
Date Invoice #
Date
Invoice #
FLOOR REIN.
COVER REIN.
INSUL REIN.
VB REIN.
FINAL REIN.
Date
R CODE COMPLIANCE FOR
NFPA 70 - E
Date
Date
Date
City Of Tukwila
IL
1
a
RElnidicE
CITY OF TUKWILA
MAR 12 2008
PERMLTERITER
Date
AreeOffice
Return to C‘ntral Office, MS 4430 within 3 work1g-days after final inspection.
F623 -005 -000 factory permit 04 -2004 White - Olympia Canary - Inspector Pink - Customer Goldenrod - Customer
FILE C1zPY
INCOMPLETE
LTR# 1
S. 133rd
Nonvital Load Center
Device
Load (A)
per unit of
equipment
Total
quantity of
units
L1 Total load
(A)
L2 Total
load (A)
AC Circuit
Breaker
(A)
Heater (240V, 1500W)
6.25
1
6.25
6.25
20
HVAC /Fan motor
3.40
0*
15
Receptacles A wall
1.50.
1
1.5
15
Receptacles C wall
1.50
5
7.5
20
Receptacles Entry
1.50
3
4.5
20
Fluorescent lights
0.25
6
1.5
15
Switch 1 Heaters
0.125
4
0.5
15
Switch 3 Heaters
0.125
4
0.5
15
ACPOKR (240V)
0.017
1
0.02
0.02
15
UPS (240V)
„1
32.27
32.27
100
Total
49.54
43.54
200
Yellow are the fields to be filled in
According to NEC - 220 -13 each receptacle draws 180VA (1.5A @ 120V)
Calculation utilizes the higher heater load only as fan and heaters are interlocked to prevent
simultaneous operation.
S. 133rd
Vital Load Center
Device
Load
coefficient/quantity
L1 load (A)
L2 load
(A)
AC
Circuit
Breaker
(A)
AF Power supply PRR 28 -36M (1TBO)
0.76
9.93
20
AF Power supply PRR 28 -36M (2TBO)
0.76
9.93
20
AF Power supply PRM 28 -17 (RBO)
0.32
2.10
15
Converter for Power frequency track circuits
0.13
1.63
20
Switch(s) 1*
2
28.00
30
Switch(s) 3*
2
28.00
30
Alarm Panel
1
0.30
15
B12 power supply primary
0.31
3.99
20
B12 power supply redundant
0.13
1.65
20
Communication equipment (W)
600
1
5.00
15
Maintenance computer (W)
200
.1
1.67
15
LED signals (W)
10
4
0.33
15
TC circuits (V -TAG & Modem)
W
Quantity of
interrogators
D
0.00
-
0
0.00
-
Total
31.58
32.96
200
* Switch circuits allow only one crossover to be thrown at a time.
Full current for each switch rectifier is displayed to size AC circuit breaker only. Adjust formula(s) per comment
fields.
S. 133rd Location Summary
O
O
N
t Q
0)
0 J
t
C
Y
U
U ° m
Q Z
E
7
E
X C
2
l
a7
m
Vital Load Center
j
0
U
rn
c
CO
m
O
0
O
O
N
2
w
C
N
U
U
aC
E
7
E
c
2
(0
o
N
M
M
vlap of Seattle, WA by MapQuest
Sorry! When printing directly from the browser your map may be incorrectly cropped. To print tT�e1LE.
entire map, try clicking the "Printer- Friendly" link at the top of your results page.
P lt ■7o.
Plar review approvtd is sikject to errors and omissions.
Approval of construt tlon documents does not authorize
* Seattle, WA US the *tenon _
_.. _ .._. �adopted code Of
allot
Page 1 of
Sorry! When printing directly from the browser your map may be incor.oftopgavad- t and conditions a
entire map, try clicking the "Printer-Friendly" link at the top of your results page. "^'v� conditi e
P, rY 9 Y° P Y P 9
Ott)tl _....:.
zoo
1, oats w
tit 2007 NAVT Cr ortTeleAbas
All rights reserved. U eSulbject to Li n right
This map t�ja " eieie{pr�c nt n is made or warranty given as to its content. User assumes all risk of use. MapQuest and its suppliers assume
no res o sibiliREVI I ti om such use.
CODE COMP NEC V
NFPA 7
APR - 3 2008
,p \ \v Vet
C.
qty Of Tukwila �� #�. (0,;a
ILDING
:i\: ,�. \\ ova ° '6 (,°46 °°°C)9
Ittp: / /www. mapquest. com/maps /map. adp ?formtype= address &addtohistory = &address = &city= seattle &state... 1/1 7/20
public W'crks. Ru Idinq Division
FERMI NUMBER
/33R./) ST S"/,fc/A GAL0V/
S. 133rd
Nonvital Load Center
Device
Load (A)
per unit of
equipment
Total
quantity of
units
L1 Total load
(A)
L2 Total
load (A)
AC Circuit
Breaker
(A)
Heater (240V, 1500W)
6.25
6.25
6.25
HVAC /Fan motor
Receptacles A wall
3.40
20
15
1.5
Receptacles C wall
1.50
7.5
Receptacles Entry
1.50
4.5
Fluorescent lights
Switch 1 Heaters
0.25
0.125
1.5
0.5
Switch 3 Heaters
0.12:
0.5
ACPOKR (240V)
0.017
0.02
0.02
15
20
20
15
15
15
15
UPS (240V)
32.27
32.27
Total
49.54
Yellow are the fields to be filled in
According to NEC - 220 -13 each receptacle draws 180VA (1.5A @ 120V)
43.54
* Calculation utilizes the higher heater load only as fan and heaters are interlocked to prevent
simultaneous operation.
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
APR - 3 2008
City Of Tukwila
B ILD. N ' IVI ION
100
200
JAN 3Q:
0.76
9.93
20
S. 133rd
Vital Load Center
Device
Load
coefficient/quantity
L1 load (A)
L2 load
(A)
AF Power supply PRR 28 -36M (1TBO)
AF Power supply PRR 28 -36M (2TBO)
0.76
9.93
AC
Circuit
Breaker
(A)
20
AF Power supply PRM 28 -17 (RBO)
Converter for Power frequency track circuits
0.32
2.10
15
0.13
1.63
20
Switch(s) 1*
28.00
30
Switch(s) 3*
28.00
30
Alarm Panel
1
0.30
B12 power supply primary
0.31
3.99
15
20
B12 power supply redundant
0.13
1.65
20
Communication equipment (W)
Maintenance computer (W)
600,
5.00
15
LED signals (W)
TWC circuits (V -TAG & Modem)
1C
Quantity of
interrogators
1.67
0.33
0.00
15
0.00
Total
31.58
32.96
200
* Switch circuits allow only one crossover to be thrown at a time.
Full current for each switch rectifier is displayed to size AC circuit breaker only. Adjust formula(s) per comment
fields.
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
APR - 3 2008
City Of Tukwila
I DIN DM I S N
S. 133rd Location Summary
N
= 3 N
To O
Fo- a , ce
Q c rn
c
co
2
To 6 m`
• co
c `)
• m
O
O
N
CA --
O J
L
co a)
U > f0
O d
U
Q Z
E
• 2
.E U
• c
2 co
2
3
of
0) Q
o • J
C of
c co
= • 0
U • Z c=i
< U
3
c
a)
U
v
0
To-
J
5a
O
w
w
c a)
• raa
L a1
U a
Q
cU
E c
x a)
a)2
To
> Q
O) J
L. C Y
+r3
.CT3 CO
c 2 m
U 2
UQ U
(o
M
CO
tq
M
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
APR - 3 2008
City Of Tukwila
BUILDING DIVISION
S/ '
cIT : •
JAN 3 0 ?
Fitl- itv.11 lair t Lri
09 -08 -2008
MICHAEL A BELLO
6533 3 AV S
SEATTLE WA 98108
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development
RE: Permit No. EL08 -094
4522 S 133 ST TUKW
Dear Permit Holder:
Jack Pace, Director
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the
Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does
allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests
must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from
being taken.
In the event you do not call for the above inspection and receive an extension prior to 10/13/2008 , your permit will become null and
void and any further work on the project will require a new permit application and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fer Marshall
't Technician
xc:
Permit File No. EL08 -094
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665
February 28, 2008
•
Cizy of Tukwila
•
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
Michael A. Bello
6533 Third Avenue South
Seattle, WA 98108
RE: Letter of Incomplete Application # 1
Electrical Permit Application EL08 -094
Sound Transit — 4522 South 133`d Street
Dear Mr. Bello,
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
January 30, 2008 is determined to be incomplete. Before your application can continue the plan review
process the following item from the following department needs to be addressed:
Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning
the following comments.
1. Provide Labor and Industries inspection report for electrical.
Please address the comment above in an itemized format with applicable revised plans, specifications, and /or
other documentation. The City requires that three (3) sets of revised plans, specifications and /or other
documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I
have enclosed one for your convenience. Revisions must be made in person and will not be accepted
through the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Sincerely,
16-
Brenda Holt
Permit Coordinator
Enclosures
File: EL08 -094
P:\Permit Center\Incomplete Letters\2008\EL0S -094 incomplete Ltr #1.DOC
wer
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
*EMIT COORD COPY �
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: E1_08 -094 DATE: 03 -13 -08
PROJECT NAME: SOUND TRANSIT
SITE ADDRESS: 4522 S 133 ST
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # After Permit Issued
DEPARTMENTS:
ding division
Public Works
Fire Prevention ri Planning Division
Structural
Permit Coordinator
U
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete Fr Incomplete ri
Comments:
DUE DATE: 03 -18-08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUT NG:
Please Route Structural Review Required ri No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 04-15-08
Approved Approved with Conditions FVf Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
PERMIT COORD COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -094 DATE: 01 -30 -08
PROJECT NAME: SOUND TRANSIT
SITE ADDRESS: 4522 S 133 ST
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPART ENTS:
Bu I ing i ion
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete U
Comments:
Incomplete
DUE DATE: 01-31-08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg Vj Fire ❑ Ping ❑ PW ❑ Staff Initials: i./
TUES/THURS ROUTING:
Please Route Li Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 02-28 -08
Approved ❑ Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28-02
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206- 431 -3665
Web site: http: / /www.ci.tukwila.wa. us
REVISIU. T.- SIBIVIITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 3//2� E-
Plan Check/Permit Number: EL00 -094
• Response to Incomplete Letter # 1
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
RECEIVED
rrrVOFTUk
MAR 12 2ffl]
Project Name: SOUND TRANSIT
Project Address: 4522 South 133rd Street
Contact Person: Michael Bello Phone Number: (206v) 76 2-7 6 a
Summary of Revision:
14TTA CHO !_q,Cao2 5' /MOWT/L/OE /A/SPEC-770N / /2-EPO/ T
Sheet Number(s):
"Cloud" or highlight all areas of revision including date o
Received at the City of Tukwila Permit Center by:
krEntered in Permits Plus on
014(1-1.D')
revision
\applications\Porms- applications on Iine\revision submittal
Created: 8 -13 -2004
Revised:
Look Up a Contractor, Electnan or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
LKCOMCI3 I 2CR
Licensee Name
L K COMSTOCK & CO INC
Licensee Type
ELECTRICAL CONTRACTOR
UBl
600045260
Ind. ins. Account Id
Business Type
CORPORATION
Address 1
5 PENN PLAZA 12TH FLOOR
Address 2
City
NEW YORK
County
OUT OF STATE
State
NY
Zip
10001
Phone
2125027900
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
2/19/1969
Expiration Date
6/17/2008
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
ORCUTDD974PW
Master Electrician Information
License
ORCUTDD974PW
Name
ORCUTT, DOUGLAS D
Status
ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
AZARELA, MICHAEL R
01/01/1980
LARKIN, JOHN G
01/01/1980
MOORE, C WILLIAM
01/01/1980
GEORGE, KEITH
01/01/1980
•
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= LKCOMCI312CR 04/08/2008
BOEING ACCESS
L & 1 GOLD SEAL APPROVAL NO. FBS43792
r
GENERATOR P
»•
RATED
100A
»-
>
»--
TO
GROUND GRID
VIA STRUCTURE
GNO
NEU
L2
L1
DISCONNECT
DISTRIBUTION
PANEL
MAIN
1- IC /2
3 -IC /2
1C 56
RATED
100A
TO
GROUND GRID
VIA STRUCTURE
1C 56
GND
T PERMITTED UNDER C755
PERMIT NO. /2809/2E
z
Z
1C /6
3 -1C #2()CHHW)
HOUSE LOAD
6.93 KVA
NEU
W
0
z
NEU
L2
L1
W
z
z
U
GROUND GRID
NON -VITAL VIA STRUCTURE
LOAD CENTER
TRANMANsFEUALR SWITCI$ RAC
4— 1C 56
3 -1C /2
UPS
4 4
4
D
_0
UPS LOAD
2.94 KW
3 -IC 52
4— 1C /6
MAIN
•
NEU
GND
VITAL
LOAD CENTER
1
L J
DISTRIBUTION
PANEL
PERMITTED UNDER
PERMIT NO. /2809/2 E
133RD STREET
L & I GOLD SEAL APPROVAL NO. FBS45651
J J
1C /6
4 3 1 C 52 (XHHW)
tJ
z
HOUSE 2.8 LOAD
VA
4_, NEU
TO
4" GROUND GRID
NON -VITAL VIA STRUCTURE
LOAD CENTER
GENERATOR
PLUG
■''
>?- L2 ■ ■ 1111
L1 iil%7ii
RATED
100A
L
FUSED
DISCONNECT
NEU
TO
GROUND GRID
VIA STRUCTURE
3 -1C /2
IC /6
RATED
100A
TO
GROUND GRID 1
VIA STRUCTURE
GND
IC /6
3 -IC /2
UPS LOAD
10.8 KW
3 IC 12
IC 56
VITAL
LOAD CENTER
1
ITM - - _.
JAN 3.0 . .3
It thll +tI 1 LC,�.
J
Designed Bye
KLW
A
M -11 -07
No. Pate
rKLW
Dsn.
r
Dorn Byc
Checked By
SAT
.sJs
s.1s
AS SUBMITTED
Ago-
Revisions
Approved By •
GETS
Global Signaling
SOUNDTRANSIT
Scd
NTS
Submitted
Dote:
Dote:
F9enome:
0145SPD003.DWG
Contract No.:
RTA/LR95- 03/C802
Dote:
10 -11 -07
LINK LIGHT RAIL PROJECT
SIGNAL SYSTEM
SIGNAL POWER DISTRIBUTION
C755
BOEING ACCESS /133RD STREET
'Drawing No.:
SPD- 3
Sheet No.:
Rev.:
003 A
SIDE "B"
DRAIN WIRE GROUND BUSS
NOTE 5.
6 FOOT #4 AWG GROUND PIGTAIL FROM STATION
GROUND OR GROUNDING RING THROUGH FOUNDATION
SLAB FOR CONNECTION TO BUNGALOW BUSS.
(INSTALLED BY FACILITES CONTRACTOR)
NOTE 5.
#6 GRN
PRIME GROUND BUSS
GROUND
DETECTORS
SIDE "C"
#4 AWG BARE COPPER
irBURIED IN EARTH A MINIMUM OF 18"
INSTALLED BY FACILITIES
ONTRACTOR)
EO;MENT RACK
SIDE "D"
#6 GRN FROM EACH RACK TO PRIME GROUND PLATE
#6 GRN TEST GROUND
#6GRN FROM EACH
PRIME GROUND PLATE
NOTE 5.
COPPER ▪ C I I I COPPER
is
?�G
Pi-
ox
01_0
efg
gag
l 14
Sew
8
Designed By
SIGNAL POWER
LOAD CENTER
HOUSE POWER
LOAD CENTER
U
MANUAL
TRANSFER
SWITCH
FUSED \ GENERATOR
DISCONNECT RECEPTACLE
(GROUND TO
TRUCTURE)
SIDE "A"
UPS
BYPASS
SWITCH
Scots
MAT
Cneeked Br
GETS
Global Signaling
SOUNDTRANSIT
A D6 -15 -0i
MAT CRK SJS
AS SUBMITTED
Sutunitted:
Dote:
NTS
Filename:
01 45658094.DWG
Controet No.:
RTA/LR95- 03/C802
Dots.
No. Date Dsn. Cnk App. Revisions
05 -31 -07
1/2 — 13 SILICON BRONZE
GROUNDING STUD LOCATED
ALL FOUR CORNERS.
PLhi.0 t Lil:i4
NOTES:
1. ALL RACK — MOUNTED EQUIPMENT REQUIRING GROUNDING
WILL BE CONNECTED TO THE PRIME GROUND
PLATE VIA THE RACK GROUND STUD LOCATED
ON THE REAR OF EACH RACK.
2. EACH EQUIPMENT RACK IS ISOLATED FROM
GROUND EXCEPT FOR THE GROUND WIRE
CONNECTION TO THE PRIME GROUND PLATE.
3. ALL UGH TING ARRESTORS MOUNTED ON THE MTB WILL
BE CONNECTED TO THE PRIME GROUND PLATE AS
SHOWN ON THE TERMINAL BOARD LAY OUT DRAWINGS.
4. ALL HOUSE CIRCUITS WILL GROUND TO THE LOAD CENTER
GROUND BUSS WHICH IN TURN IS CONNECTED TO A
GROUND STUD LOCATED ON THE FLOOR DIRECTLY
BELOW THE LOAD CENTER.
5. FLOOR GROUND STUD.
6.WIR£ CHASE WILL GROUND TO THE HOUSE POWER LOAD
CENTER.
LINK LIGHT RAIL PROJECT
SIGNAL SYSTEM
133RD STREET
10' X 24' HOUSE GROUNDING ARRANGEMENT
Droning NO.:
658 -094
Silent No.: Rev.:
094 A
PE-3307 ( it).- 4
\
843
- ti GROUND I NG
0AL I _ - -
L00-0100 100-0100 NOTE 2
S I -MAC .BUI40AL0W
844
FOUNDATION N
SC-7526 (6-4)
LV-7503
------ _
AUXILIARY Y ELECTRICAL L
CAB I NET (N I C)
I_ v -7 #4 ( I -2
.
.
- . ...
/ ,
-- --- -J
/ 1 - ----- _
I-
I
T-3
6-4)
\-MY-3,301 (2-4)
TPSS - C33
/ ROVIDAT ON
NOTES
0-
TE MH-330 I (2)
rr-3311 (5-4
/
DIANCE ACCESS
STAIR TOWER
FT:CT:777D
JAN 3 0
I. MANHOLE, DUCTBANK AND CONDUITS SHOWN
FOR I NFORMAT ION ONLY. W I LL BE I NSTALLED
BY CIVIL CONTRACTOR.
2. S I GNAL BUNGALOW FOUNDAT I ON AND GROUNDING
WILL. BE INSTALLED BY CIVIL CONTRACTOR.
DETAIL
SCALE: 1' = 5 L57-0002
157-G478
0 5 ID.
1;tt
SCALE IN FEET
zays
Ibmwhoil
ax-ant
threseImod
uxnt
i -i
3
4
5
00
to mN
1-
IS
A 10/09/06 KLY RME
o . 0 03/15/05
No.
20' (MAX)
a
PLUG -IN
•
PHOTO CONTROL
RELAY WITH
TAMPERPROOF -
CAGE
38'
i
120V CCI DUPLEX
® RECEPTACLE WITH LOCKABLE*
WEATHERPROOF COVER
LEFT SIDE ELEVATION
NOTE 2
9J
•BRANCH CIRCUIT PANEL
AND . LI GHT ING CONTROLS
CT= ] GROUND BUS
1 ( ITT u
t B' h p 1 }`
t- I 9 �_N 1
T
- 1
#1 D /0 BARE TO
NOTES:
1. ELECTRICAL CABINET SHALL BE FABRICATED
FROM STAINLESS STEEL WITH
NQN- DIRECTIONAL BRUSH PATTERN. DOOR.
SHALL BE PADLOCKASLE WITH
-THREE -POINT LATCHES. •
2. FOR ELECTRICAL•ONE LINE DIAGRAM AND
BLOCK DIAGRAM SEE DETAILS 3 AND 4.
.3. VERIFY BL0 KOUT LOCATIONS WITH
CABINET MANUFACTURER.
4. PROVIDE A MANUAL SWITCH (LOCKABLE)
RATED FOR 480V. SQUARE D CLASS 2510
TYPE K OR APPROVED EQUAL
6. PROVIDE A 150 VA GENERAL PURPOSE
TRANSFORMER, 480/240V I0 PRIMARY WITH
A 120V SECONDARY.
•
6. PROVIDE AND MOUNT A 12'x12'x6' DEEP
NEMA 12 ENCLOSURE WITH A HINGED DOOR.
MOUNT AND LABEL COMPONENTS.
7. CONNECT UN - ORMER SECONDARY
LOAD _ti: �,.r; iN a OUND CABLE IN THE
FRONT ELEVATION
AUXILIARY ELECTRICAL CABINET n
SCALE: 1 = L'-•0' L57 -.008
SCHEMATIC DIAGRAM
SCALE NTS
Deegned Bx
R. EACKER
Dote
RME
CNWD #128
ISSUED FOR CONSTRUCT! ON
ban.
CAk.
Revbiane
Drown the
B. PORTER
Checked Bye •
M. DURNETT
Approved By
Jl DESANTO
Submitted:
E. ROWE
Ootte
SCALE 1' = I'-0'
PANELBOARD
LI GHT !NG
CONTROLLER
L57 -J008
L57-41320 THRU .023
•
CABINET MOUNTED
PHOTO CONTROL
SEE SPECIFICATIONS KTK 2 AMP
FOR REQUIREMENTS FUSE W/HOLDER
NON - CONTROLLED CONTROLLED LIGHTING
BRANCH CIRCUITS' BRANCH CIRCUITS
LIGHTING CONTROLLER BLOCK DIAGRAM (41
SCALE NTS L57�
03/15/05
SOUNL1fRANsIT
R. KEMPKES
Dote:
Stake
AS SHOWN
Flamm,
S55J.57— J008.dwg
Contrite! No
03/t5/06
-Dote:
C 755
09/13/04
:77)
cITV - "n
JAN 3 0
PEhilvi1.+
CCTV AND INTRUSION
DETECTOR POWER ' CAB.I NET re 1
SCALE NTS - 157.t08
L57 -.P19, .P22
Drawing Na:
I GHT RAIL PROJECT L57 -JD08
LINKL
SOUTH CORRIDOR
AUXILIARY ELECTRICAL
CAB1NET DETAILS
Street No.:
Rev.:
1420 A