Loading...
HomeMy WebLinkAboutPermit EL08-0094 - SOUND TRANSITSOUND TRANSIT 4522 S 133 ST ELO8-094 CRAM' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2613200006 Address: 4522 S 133 ST TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -094 Issue Date: 04/08/2008 Permit Expires On: 10/05/2008 Tenant: Name: SOUND TRANSIT Address: 4522 S 133 ST , TUKWILA WA Owner: Name: SHEEHAN PAUL E Phone: Address: PO BOX 68726 , TUKWILA WA Contact Person: Name: MICHAEL A BELLO Phone: 206 762 -7684 Address: 6533 3 AV S , SEATTLE WA Contractor: Name: L K COMSTOCK & CO INC Phone: 212 - 502 -7900 Address: 5 PENN PLAZA 12TH FLOOR , NEW YORK NY Contractor License No: LKCOMCI312CR Expiration Date: 06/17/2008 DESCRIPTION OF WORK: SET AND ENERGIZE SIGNAL BUNGALOW AT 133 ST Value of Electrical: $5,000.00 Fees Collected: $205.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Date: t—'"l!'o I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: ay, Print Name: AW/ J' A L Date: �C /G.f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -094 Printed: 04 -08 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2613200006 Address: 4522 5 133 ST TUKW Suite No: Tenant: SOUND TRANSIT PERMIT CONDITIONS Permit Number: EL08 -094 Status: ISSUED Applied Date: 01/30/2008 Issue Date: 04/08/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: �° �`"� Date: ��GP /oc Print Name: ,4 //DDS 7 Ef'44%,4 ■I/e doc: Cond -Elec EL08 -094 Printed: 04 -08 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: Site Address: 4522 S. /33RD s'T. TQ 4 W /C,A WA 98/68 Suite Number: Floor: Tenant Name: .90GOVD TiCAMS/ C /T New Tenant: ❑ Yes ❑ ..No Property Owners Name: SOUND TRANS /T Mailing Address: *0/ 30(47# v'ACI Po,V `97; c,S'EATTL E WA 93/64 11222 L) CC z.zl Name: /0/CNAE[.. A . 8EL LC) Mailing Address: 6533 3R.D AVEN'WE SOuTN/ 1416el/o r ii /worA.s , c0 E -Mail Address: Day Telephone: (2 O 6> 76 2-76 8¢ SGAT`TG ' 98/08 City State Zip Fax Number: ( 2 0G,) 76 2 - 76 95 Company Name: L . / . COMS7OCk ' CO /NC Mailing Address: S PENN PGA eA 1 / 2 T,4 FL oOR It/E'Ge) YO, e Contact Person: M /CHA EL f{ . 16 EC-(.0 E -Mail Address: 14,76e/ /o @ seal/we) rks . Cowl Fax Number: (20 (o) 76 2 - 7695 Contractor Registration Number: EC() / 1..00/1/1 CI3 /2 C Expiration Date: DG // 7/0 i@ 8 City Day Telephone: (20 Co) 76 2 - 76,Q N Y /000/ State Zip Valuation of Project (contractor's bid price): $ $j 000 Scope of Work (please provide detailed information): SET AND NE' G% E S /,(yNA ,BU,(IGA LOW Ar Will service be altered? ❑ Yes Q(No Type of Use: Type of work: B' New El Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator El Fire Alarm [V]rTelecommunication ❑ Temporary Service Adding more than 50 amps? ❑ Yes ❑ No Property Served by: ❑ Puget Sound Energy Rif Seattle City Light H: ApplicationsWonns- Applications On fine4-2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea 1ESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Value of Construction -- In all cases, a value of constriction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: M /CHAes�C_ .4 . £ EGGU Day Telephone: Mailing Address: 6533 340 AVE SOUTH SEATTG6 IDate Application Accepted: City Date: //30/08 ( 2 0 6 ) 7 6 2 — 7 6 6 ' 0 WA( 980 /8 State Zip Staff' Initials: Date Application Expires: N.. 101,..d.23 H: ApplicationsWonns- Applications On Line\4 -2007 - Electrical Permit it Applcation.dac bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 2613200006 Address: 4522 S 133 ST TUKW Suite No: Applicant: SOUND TRANSIT RECEIPT Permit Number: EL08 -094 Status: APPROVED Applied Date: 01/30/2008 Issue Date: Receipt No.: R08 -01077 Payment Amount: $164.00 Initials: WER Payment Date: 04/08/2008 01:24 PM User ID: 1655 Balance: $0.00 Payee: L K COMSYOCK TRANSACTION LIST: Type Method Descriptio Amount Payment Check 118900 164.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 164.00 Total: $164.00 don. Raraint -08 Printpd 04- n8 -200R • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: htv/Iwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -00260 Initials: JEM User ID: 1165 Payee: MICHAEL BELLO Payment Date: 01/30/2008 Total Payment: 123.00 SET ID: 0130 SET NAME: SOUND TRANSIT SET TRANSACTIONS: Set Member Amount EL08 -093 41.00 EL08 -094 41.00 EL08 -095 41.00 TOTAL: 123.00 TRANSACTION LIST: Type Method Description Amount Payment Cash 123.00 TOTAL: 123.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 123.00 TOTAL: 123.00 7789 01/30 9710 TOTAL 123.00 Doc: RECSETS -OR INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. Pr 'ect: ow) T.1),AjS •• 7- Type of Inspection: ,,, / Aide s: L� -� -, _ /.+1l ,. -- / ., Date Called: Special Instructions: Date Wanted: /��` S V p.m. Requester: Phone No: A • • roved per applicable codes. 11 Corrections required prior to approval. f. COMMENTS: • ft' /% /7 fJ0 04/ / Inspecto `�,t` yo Date://, El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: P.vaAM4f r..w YleE` •L ea. J awl' -1 LAN. mi:xsi_: b INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit latc-ogy PER NO. (206)431 -3670 Project: Type of Inspection: A dr ss: 2 ,C ,71Ra c Date Called: Special Instructions: Date Wanted: , I J,� /g� // a.m. p.m. Requester: Phone No: AO oved per applicable codes. Ei Corrections required prior to approval. COMMENTS: wv/c.e. SX•ve \'*1 Ay416110W Insp GL &TfvMk'/1 Date: y46 /a El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT O. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prooject: ``w,& -�s ` /-r ri C---/(■__ .c Type of Insp Pci n: 14. <E 1 �cyn i F Address: 12 g p 112- ,5 1...-.._.7 t ...)1 Date Called: c_zu //e/ . Special Instructions: Date Wanted�� a.m. p.m. Requester: Phone No: ❑ Approved per applicable codes. rrections required prior to approval. COMMENTS: ri C---/(■__ .c IMOY/Y 14. <E 1 �cyn i F r bite rh % /Wman li 2I(4 /Jo r Rc. L, r' , /V- ze-A ,'zed f /GM c_zu //e/ . Inspect //G Date` /r /ir( ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: 9162299677 GE Transportation Department of Labor and Industries Factory Assembled Structures POBox44430 Olympia WA 98504-4430 ONE,PERMIT PER FLOOR 08:01:08 a. m. 03 -11 -2008 3 /4 FACTORY PERMIT Do not complete shadkd area Permit 71177 Manufacturer No Contact Phone Manufacturer, Phone Address City _24 Q;L Please check the appropriate box indicating the type of floor (unit) t) t be inspected model number and plan approval number in the spaces provided. ❑ Commercial Coach Factory Built Structures Temporary Worker Housing Vendor/ Medical Units F;44- 7$J -Z3? ' r1 State Zip �S hMi and list the serial number, Serial No. Model No. Plan Approval Number DRFA' b?OQO ?Z_ L&I Department Use Only FLOOR r COVER J t7 INSULATION / ' VAPOR BARRIER FINAL L. Date u Date 7 -v? Date • / • Invoice # Invoice # 1 Invoice # Date Invoice # Date Invoice # FLOOR REIN. COVER REIN. INSUL REIN. VB REIN. FINAL REIN. Date R CODE COMPLIANCE FOR NFPA 70 - E Date Date Date City Of Tukwila IL 1 a RElnidicE CITY OF TUKWILA MAR 12 2008 PERMLTERITER Date AreeOffice Return to C‘ntral Office, MS 4430 within 3 work1g-days after final inspection. F623 -005 -000 factory permit 04 -2004 White - Olympia Canary - Inspector Pink - Customer Goldenrod - Customer FILE C1zPY INCOMPLETE LTR# 1 S. 133rd Nonvital Load Center Device Load (A) per unit of equipment Total quantity of units L1 Total load (A) L2 Total load (A) AC Circuit Breaker (A) Heater (240V, 1500W) 6.25 1 6.25 6.25 20 HVAC /Fan motor 3.40 0* 15 Receptacles A wall 1.50. 1 1.5 15 Receptacles C wall 1.50 5 7.5 20 Receptacles Entry 1.50 3 4.5 20 Fluorescent lights 0.25 6 1.5 15 Switch 1 Heaters 0.125 4 0.5 15 Switch 3 Heaters 0.125 4 0.5 15 ACPOKR (240V) 0.017 1 0.02 0.02 15 UPS (240V) „1 32.27 32.27 100 Total 49.54 43.54 200 Yellow are the fields to be filled in According to NEC - 220 -13 each receptacle draws 180VA (1.5A @ 120V) Calculation utilizes the higher heater load only as fan and heaters are interlocked to prevent simultaneous operation. S. 133rd Vital Load Center Device Load coefficient/quantity L1 load (A) L2 load (A) AC Circuit Breaker (A) AF Power supply PRR 28 -36M (1TBO) 0.76 9.93 20 AF Power supply PRR 28 -36M (2TBO) 0.76 9.93 20 AF Power supply PRM 28 -17 (RBO) 0.32 2.10 15 Converter for Power frequency track circuits 0.13 1.63 20 Switch(s) 1* 2 28.00 30 Switch(s) 3* 2 28.00 30 Alarm Panel 1 0.30 15 B12 power supply primary 0.31 3.99 20 B12 power supply redundant 0.13 1.65 20 Communication equipment (W) 600 1 5.00 15 Maintenance computer (W) 200 .1 1.67 15 LED signals (W) 10 4 0.33 15 TC circuits (V -TAG & Modem) W Quantity of interrogators D 0.00 - 0 0.00 - Total 31.58 32.96 200 * Switch circuits allow only one crossover to be thrown at a time. Full current for each switch rectifier is displayed to size AC circuit breaker only. Adjust formula(s) per comment fields. S. 133rd Location Summary O O N t Q 0) 0 J t C Y U U ° m Q Z E 7 E X C 2 l a7 m Vital Load Center j 0 U rn c CO m O 0 O O N 2 w C N U U aC E 7 E c 2 (0 o N M M vlap of Seattle, WA by MapQuest Sorry! When printing directly from the browser your map may be incorrectly cropped. To print tT�e1LE. entire map, try clicking the "Printer- Friendly" link at the top of your results page. P lt ■7o. Plar review approvtd is sikject to errors and omissions. Approval of construt tlon documents does not authorize * Seattle, WA US the *tenon _ _.. _ .._. �adopted code Of allot Page 1 of Sorry! When printing directly from the browser your map may be incor.oftopgavad- t and conditions a entire map, try clicking the "Printer-Friendly" link at the top of your results page. "^'v� conditi e P, rY 9 Y° P Y P 9 Ott)tl _....:. zoo 1, oats w tit 2007 NAVT Cr ortTeleAbas All rights reserved. U eSulbject to Li n right This map t�ja " eieie{pr�c nt n is made or warranty given as to its content. User assumes all risk of use. MapQuest and its suppliers assume no res o sibiliREVI I ti om such use. CODE COMP NEC V NFPA 7 APR - 3 2008 ,p \ \v Vet C. qty Of Tukwila �� #�. (0,;a ILDING :i\: ,�. \\ ova ° '6 (,°46 °°°C)9 Ittp: / /www. mapquest. com/maps /map. adp ?formtype= address &addtohistory = &address = &city= seattle &state... 1/1 7/20 public W'crks. Ru Idinq Division FERMI NUMBER /33R./) ST S"/,fc/A GAL0V/ S. 133rd Nonvital Load Center Device Load (A) per unit of equipment Total quantity of units L1 Total load (A) L2 Total load (A) AC Circuit Breaker (A) Heater (240V, 1500W) 6.25 6.25 6.25 HVAC /Fan motor Receptacles A wall 3.40 20 15 1.5 Receptacles C wall 1.50 7.5 Receptacles Entry 1.50 4.5 Fluorescent lights Switch 1 Heaters 0.25 0.125 1.5 0.5 Switch 3 Heaters 0.12: 0.5 ACPOKR (240V) 0.017 0.02 0.02 15 20 20 15 15 15 15 UPS (240V) 32.27 32.27 Total 49.54 Yellow are the fields to be filled in According to NEC - 220 -13 each receptacle draws 180VA (1.5A @ 120V) 43.54 * Calculation utilizes the higher heater load only as fan and heaters are interlocked to prevent simultaneous operation. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 3 2008 City Of Tukwila B ILD. N ' IVI ION 100 200 JAN 3Q: 0.76 9.93 20 S. 133rd Vital Load Center Device Load coefficient/quantity L1 load (A) L2 load (A) AF Power supply PRR 28 -36M (1TBO) AF Power supply PRR 28 -36M (2TBO) 0.76 9.93 AC Circuit Breaker (A) 20 AF Power supply PRM 28 -17 (RBO) Converter for Power frequency track circuits 0.32 2.10 15 0.13 1.63 20 Switch(s) 1* 28.00 30 Switch(s) 3* 28.00 30 Alarm Panel 1 0.30 B12 power supply primary 0.31 3.99 15 20 B12 power supply redundant 0.13 1.65 20 Communication equipment (W) Maintenance computer (W) 600, 5.00 15 LED signals (W) TWC circuits (V -TAG & Modem) 1C Quantity of interrogators 1.67 0.33 0.00 15 0.00 Total 31.58 32.96 200 * Switch circuits allow only one crossover to be thrown at a time. Full current for each switch rectifier is displayed to size AC circuit breaker only. Adjust formula(s) per comment fields. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 3 2008 City Of Tukwila I DIN DM I S N S. 133rd Location Summary N = 3 N To O Fo- a , ce Q c rn c co 2 To 6 m` • co c `) • m O O N CA -- O J L co a) U > f0 O d U Q Z E • 2 .E U • c 2 co 2 3 of 0) Q o • J C of c co = • 0 U • Z c=i < U 3 c a) U v 0 To- J 5a O w w c a) • raa L a1 U a Q cU E c x a) a)2 To > Q O) J L. C Y +r3 .CT3 CO c 2 m U 2 UQ U (o M CO tq M REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 3 2008 City Of Tukwila BUILDING DIVISION S/ ' cIT : • JAN 3 0 ? Fitl- itv.11 lair t Lri 09 -08 -2008 MICHAEL A BELLO 6533 3 AV S SEATTLE WA 98108 City of Tukwila Jim Haggerton, Mayor Department of Community Development RE: Permit No. EL08 -094 4522 S 133 ST TUKW Dear Permit Holder: Jack Pace, Director In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/13/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall 't Technician xc: Permit File No. EL08 -094 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 o Fax: 206 - 431 -3665 February 28, 2008 • Cizy of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Michael A. Bello 6533 Third Avenue South Seattle, WA 98108 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -094 Sound Transit — 4522 South 133`d Street Dear Mr. Bello, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 30, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide Labor and Industries inspection report for electrical. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, 16- Brenda Holt Permit Coordinator Enclosures File: EL08 -094 P:\Permit Center\Incomplete Letters\2008\EL0S -094 incomplete Ltr #1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 *EMIT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: E1_08 -094 DATE: 03 -13 -08 PROJECT NAME: SOUND TRANSIT SITE ADDRESS: 4522 S 133 ST Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: ding division Public Works Fire Prevention ri Planning Division Structural Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Fr Incomplete ri Comments: DUE DATE: 03 -18-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required ri No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04-15-08 Approved Approved with Conditions FVf Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -094 DATE: 01 -30 -08 PROJECT NAME: SOUND TRANSIT SITE ADDRESS: 4522 S 133 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART ENTS: Bu I ing i ion Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete U Comments: Incomplete DUE DATE: 01-31-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Vj Fire ❑ Ping ❑ PW ❑ Staff Initials: i./ TUES/THURS ROUTING: Please Route Li Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02-28 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa. us REVISIU. T.- SIBIVIITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3//2� E- Plan Check/Permit Number: EL00 -094 • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED rrrVOFTUk MAR 12 2ffl] Project Name: SOUND TRANSIT Project Address: 4522 South 133rd Street Contact Person: Michael Bello Phone Number: (206v) 76 2-7 6 a Summary of Revision: 14TTA CHO !_q,Cao2 5' /MOWT/L/OE /A/SPEC-770N / /2-EPO/ T Sheet Number(s): "Cloud" or highlight all areas of revision including date o Received at the City of Tukwila Permit Center by: krEntered in Permits Plus on 014(1-1.D') revision \applications\Porms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electnan or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License LKCOMCI3 I 2CR Licensee Name L K COMSTOCK & CO INC Licensee Type ELECTRICAL CONTRACTOR UBl 600045260 Ind. ins. Account Id Business Type CORPORATION Address 1 5 PENN PLAZA 12TH FLOOR Address 2 City NEW YORK County OUT OF STATE State NY Zip 10001 Phone 2125027900 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/19/1969 Expiration Date 6/17/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License ORCUTDD974PW Master Electrician Information License ORCUTDD974PW Name ORCUTT, DOUGLAS D Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date AZARELA, MICHAEL R 01/01/1980 LARKIN, JOHN G 01/01/1980 MOORE, C WILLIAM 01/01/1980 GEORGE, KEITH 01/01/1980 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= LKCOMCI312CR 04/08/2008 BOEING ACCESS L & 1 GOLD SEAL APPROVAL NO. FBS43792 r GENERATOR P »• RATED 100A »- > »-- TO GROUND GRID VIA STRUCTURE GNO NEU L2 L1 DISCONNECT DISTRIBUTION PANEL MAIN 1- IC /2 3 -IC /2 1C 56 RATED 100A TO GROUND GRID VIA STRUCTURE 1C 56 GND T PERMITTED UNDER C755 PERMIT NO. /2809/2E z Z 1C /6 3 -1C #2()CHHW) HOUSE LOAD 6.93 KVA NEU W 0 z NEU L2 L1 W z z U GROUND GRID NON -VITAL VIA STRUCTURE LOAD CENTER TRANMANsFEUALR SWITCI$ RAC 4— 1C 56 3 -1C /2 UPS 4 4 4 D _0 UPS LOAD 2.94 KW 3 -IC 52 4— 1C /6 MAIN • NEU GND VITAL LOAD CENTER 1 L J DISTRIBUTION PANEL PERMITTED UNDER PERMIT NO. /2809/2 E 133RD STREET L & I GOLD SEAL APPROVAL NO. FBS45651 J J 1C /6 4 3 1 C 52 (XHHW) tJ z HOUSE 2.8 LOAD VA 4_, NEU TO 4" GROUND GRID NON -VITAL VIA STRUCTURE LOAD CENTER GENERATOR PLUG ■'' >?- L2 ■ ■ 1111 L1 iil%7ii RATED 100A L FUSED DISCONNECT NEU TO GROUND GRID VIA STRUCTURE 3 -1C /2 IC /6 RATED 100A TO GROUND GRID 1 VIA STRUCTURE GND IC /6 3 -IC /2 UPS LOAD 10.8 KW 3 IC 12 IC 56 VITAL LOAD CENTER 1 ITM - - _. JAN 3.0 . .3 It thll +tI 1 LC,�. J Designed Bye KLW A M -11 -07 No. Pate rKLW Dsn. r Dorn Byc Checked By SAT .sJs s.1s AS SUBMITTED Ago- Revisions Approved By • GETS Global Signaling SOUNDTRANSIT Scd NTS Submitted Dote: Dote: F9enome: 0145SPD003.DWG Contract No.: RTA/LR95- 03/C802 Dote: 10 -11 -07 LINK LIGHT RAIL PROJECT SIGNAL SYSTEM SIGNAL POWER DISTRIBUTION C755 BOEING ACCESS /133RD STREET 'Drawing No.: SPD- 3 Sheet No.: Rev.: 003 A SIDE "B" DRAIN WIRE GROUND BUSS NOTE 5. 6 FOOT #4 AWG GROUND PIGTAIL FROM STATION GROUND OR GROUNDING RING THROUGH FOUNDATION SLAB FOR CONNECTION TO BUNGALOW BUSS. (INSTALLED BY FACILITES CONTRACTOR) NOTE 5. #6 GRN PRIME GROUND BUSS GROUND DETECTORS SIDE "C" #4 AWG BARE COPPER irBURIED IN EARTH A MINIMUM OF 18" INSTALLED BY FACILITIES ONTRACTOR) EO;MENT RACK SIDE "D" #6 GRN FROM EACH RACK TO PRIME GROUND PLATE #6 GRN TEST GROUND #6GRN FROM EACH PRIME GROUND PLATE NOTE 5. COPPER ▪ C I I I COPPER is ?�G Pi- ox 01_0 efg gag l 14 Sew 8 Designed By SIGNAL POWER LOAD CENTER HOUSE POWER LOAD CENTER U MANUAL TRANSFER SWITCH FUSED \ GENERATOR DISCONNECT RECEPTACLE (GROUND TO TRUCTURE) SIDE "A" UPS BYPASS SWITCH Scots MAT Cneeked Br GETS Global Signaling SOUNDTRANSIT A D6 -15 -0i MAT CRK SJS AS SUBMITTED Sutunitted: Dote: NTS Filename: 01 45658094.DWG Controet No.: RTA/LR95- 03/C802 Dots. No. Date Dsn. Cnk App. Revisions 05 -31 -07 1/2 — 13 SILICON BRONZE GROUNDING STUD LOCATED ALL FOUR CORNERS. PLhi.0 t Lil:i4 NOTES: 1. ALL RACK — MOUNTED EQUIPMENT REQUIRING GROUNDING WILL BE CONNECTED TO THE PRIME GROUND PLATE VIA THE RACK GROUND STUD LOCATED ON THE REAR OF EACH RACK. 2. EACH EQUIPMENT RACK IS ISOLATED FROM GROUND EXCEPT FOR THE GROUND WIRE CONNECTION TO THE PRIME GROUND PLATE. 3. ALL UGH TING ARRESTORS MOUNTED ON THE MTB WILL BE CONNECTED TO THE PRIME GROUND PLATE AS SHOWN ON THE TERMINAL BOARD LAY OUT DRAWINGS. 4. ALL HOUSE CIRCUITS WILL GROUND TO THE LOAD CENTER GROUND BUSS WHICH IN TURN IS CONNECTED TO A GROUND STUD LOCATED ON THE FLOOR DIRECTLY BELOW THE LOAD CENTER. 5. FLOOR GROUND STUD. 6.WIR£ CHASE WILL GROUND TO THE HOUSE POWER LOAD CENTER. LINK LIGHT RAIL PROJECT SIGNAL SYSTEM 133RD STREET 10' X 24' HOUSE GROUNDING ARRANGEMENT Droning NO.: 658 -094 Silent No.: Rev.: 094 A PE-3307 ( it).- 4 \ 843 - ti GROUND I NG 0AL I _ - - L00-0100 100-0100 NOTE 2 S I -MAC .BUI40AL0W 844 FOUNDATION N SC-7526 (6-4) LV-7503 ------ _ AUXILIARY Y ELECTRICAL L CAB I NET (N I C) I_ v -7 #4 ( I -2 . . - . ... / , -- --- -J / 1 - ----- _ I- I T-3 6-4) \-MY-3,301 (2-4) TPSS - C33 / ROVIDAT ON NOTES 0- TE MH-330 I (2) rr-3311 (5-4 / DIANCE ACCESS STAIR TOWER FT:CT:777D JAN 3 0 I. MANHOLE, DUCTBANK AND CONDUITS SHOWN FOR I NFORMAT ION ONLY. W I LL BE I NSTALLED BY CIVIL CONTRACTOR. 2. S I GNAL BUNGALOW FOUNDAT I ON AND GROUNDING WILL. BE INSTALLED BY CIVIL CONTRACTOR. DETAIL SCALE: 1' = 5 L57-0002 157-G478 0 5 ID. 1;tt SCALE IN FEET zays Ibmwhoil ax-ant threseImod uxnt i -i 3 4 5 00 to mN 1- IS A 10/09/06 KLY RME o . 0 03/15/05 No. 20' (MAX) a PLUG -IN • PHOTO CONTROL RELAY WITH TAMPERPROOF - CAGE 38' i 120V CCI DUPLEX ® RECEPTACLE WITH LOCKABLE* WEATHERPROOF COVER LEFT SIDE ELEVATION NOTE 2 9J •BRANCH CIRCUIT PANEL AND . LI GHT ING CONTROLS CT= ] GROUND BUS 1 ( ITT u t B' h p 1 }` t- I 9 �_N 1 T - 1 #1 D /0 BARE TO NOTES: 1. ELECTRICAL CABINET SHALL BE FABRICATED FROM STAINLESS STEEL WITH NQN- DIRECTIONAL BRUSH PATTERN. DOOR. SHALL BE PADLOCKASLE WITH -THREE -POINT LATCHES. • 2. FOR ELECTRICAL•ONE LINE DIAGRAM AND BLOCK DIAGRAM SEE DETAILS 3 AND 4. .3. VERIFY BL0 KOUT LOCATIONS WITH CABINET MANUFACTURER. 4. PROVIDE A MANUAL SWITCH (LOCKABLE) RATED FOR 480V. SQUARE D CLASS 2510 TYPE K OR APPROVED EQUAL 6. PROVIDE A 150 VA GENERAL PURPOSE TRANSFORMER, 480/240V I0 PRIMARY WITH A 120V SECONDARY. • 6. PROVIDE AND MOUNT A 12'x12'x6' DEEP NEMA 12 ENCLOSURE WITH A HINGED DOOR. MOUNT AND LABEL COMPONENTS. 7. CONNECT UN - ORMER SECONDARY LOAD _ti: �,.r; iN a OUND CABLE IN THE FRONT ELEVATION AUXILIARY ELECTRICAL CABINET n SCALE: 1 = L'-•0' L57 -.008 SCHEMATIC DIAGRAM SCALE NTS Deegned Bx R. EACKER Dote RME CNWD #128 ISSUED FOR CONSTRUCT! ON ban. CAk. Revbiane Drown the B. PORTER Checked Bye • M. DURNETT Approved By Jl DESANTO Submitted: E. ROWE Ootte SCALE 1' = I'-0' PANELBOARD LI GHT !NG CONTROLLER L57 -J008 L57-41320 THRU .023 • CABINET MOUNTED PHOTO CONTROL SEE SPECIFICATIONS KTK 2 AMP FOR REQUIREMENTS FUSE W/HOLDER NON - CONTROLLED CONTROLLED LIGHTING BRANCH CIRCUITS' BRANCH CIRCUITS LIGHTING CONTROLLER BLOCK DIAGRAM (41 SCALE NTS L57� 03/15/05 SOUNL1fRANsIT R. KEMPKES Dote: Stake AS SHOWN Flamm, S55J.57— J008.dwg Contrite! No 03/t5/06 -Dote: C 755 09/13/04 :77) cITV - "n JAN 3 0 PEhilvi1.+ CCTV AND INTRUSION DETECTOR POWER ' CAB.I NET re 1 SCALE NTS - 157.t08 L57 -.P19, .P22 Drawing Na: I GHT RAIL PROJECT L57 -JD08 LINKL SOUTH CORRIDOR AUXILIARY ELECTRICAL CAB1NET DETAILS Street No.: Rev.: 1420 A