HomeMy WebLinkAboutPermit EL08-0095 - SOUND TRANSITSOUND TRANSIT
11001 EAST MARGINAL WY S
ELO8-095
COW' Tukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ELECTRICAL PERMIT
Parcel No.: 0323049183
Address: 11001 EAST MARGINAL WY S TUKW
Suite No:
Permit Number: EL08 -095
Issue Date: 04/08/2008
Permit Expires On: 10/05/2008
Tenant:
Name: SOUND TRANSIT
Address: 11001 EAST MARGINAL WY S , TUKWILA WA
Owner:
Name: ROBBLEE INVESTMENT CO Phone:
Address: 11010 PACIFIC HWY S , SEATTLE WA
Contact Person:
Name: MICHAEL A BELLO Phone: 206 762 -7684
Address: 6533 3 AV S , SEATTLE WA
Contractor:
Name: L K COMSTOCK & CO INC Phone: 212 - 502 -7900
Address: 5 PENN PLAZA 12TH FLOOR , NEW YORK NY
Contractor License No: LKCOMCI312CR Expiration Date: 06/17/2008
DESCRIPTION OF WORK:
SET AND ENERGIZE SIGNAL BUNGALOW AT EAST MARGINAL WY S
Value of Electrical: $5,000.00
Type of Fire Protection:
Electrical Service provided by: SEATTLE CITY LIGHT
Permit Center Authorized Signature:
w
Fees Collected:
National Electrical Code Edition:
$205.00
2005
Date: "1- Z'J --U O
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this electrical permit.
Signature: C
Print Name:
A- A) Z,2- J' 7-- &EDE k A ilk.
Date: 4 /f /o e
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -095 Printed: 04 -08 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 0323049183
Address: 11001 EAST MARGINAL WY S TUKW
Suite No:
Tenant: SOUND TRANSIT
Permit Number: EL08 -095
Status: ISSUED
Applied Date: 01/30/2008
Issue Date: 04/08/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Signature: "---
Print Name: 4./L Lf G Eb o) .
Date:
/GPlocf-
doc: Cond -Elec
EL08 -095 Printed: 04 -08 -2008
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
King Co Assessor's Tax No.: t :'-2—hek 1 i1 17'
Site Address: 9/32 -Mix t✓Q,- WAYS. SEArr WA 98//8 Suite Number:
Tenant Name: 6'0Gl/V0 rkA/VS /T
Property Owners Name: 6014/V0 712A /VS /T
Mailing Address: 40/ 9Oe471 v'/4Ct 4..r 0 A S'7,
Name: /CA/#4 EL A. BE'. G U
Mailing Address: 6533 3RD ,4VENWE 4'0077 -/
fMbe //a rai /works ,
E -Mail Address:
Floor:
New Tenant: ❑ Yes ❑ ..No
SEA T7-46" WA 98/64
4
City State Zip
Day Telephone: (2 0 6) 76 2 -7684-
SATTCE 98/08
City
Company Name: L./<, COMST0CK fl CO /NC
State Zip
Fax Number: (2 06) 76 2-7695
Mailing Address: S /' EN// PGA eA / 2T1/ F4004
Contact Person: M /C.HAEL . ,8EGLU
E -Mail Address: /416e //Q 1/0 //GOO rk,S CO 114
Contractor Registration Number: CO / LkCUNI CI3/2 C,
A/Ew Yuk,e. A/ Y /000/
City State Zip
Day Telephone: (20 G) 76 2 - 76 '
Fax Number: C2 o (,o) 76 2 - 76 95
Expiration Date: DG //7/08
Valuation of Project (contractor's bid price): $ 5 000
Scope of Work (please provide detailed information): SE AND
4T
45.47-11 S7 Z6,677-
GA/6724.-/E E SVGA/A4.- ,Bcr//O-A c.oW
Will service be altered? ❑ Yes [le-No Adding more than 50 amps? ❑ Yes ❑ No
Type of Use:
Type of work:
Q' New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm [Telecommunication ❑ Temporary Service
Property Served by:
❑ Puget Sound Energy
lien Seattle City Light
HAApplicationsWonns- Applications On lineal -2007 - Electrical Permit Application.doc
bh
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, fumace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
Value of Construcdon — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature: .T_� /d
Print Name: M /C'HAV.. 4 . 6 FLGO
Mailing Address: 6.5,3 ' 340 AVE SvG TN
Date Application Accepted:
ll
2) Dk
Date: /l3 0/0•
Day Telephone: C") 7 6 2- 76 3 0
SEATTLE WA 960 /8
city
Date Application Expires:
A:1ApplicationaWoma- Application On line\4 -2007 - Electrical Pmeit Applirationdoc
bh
State Zip
Staff Initials:
Page 2 of 2
1
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 0323049183 Permit Number: EL08 -095
Address: 11001 EAST MARGINAL WY 5 TUKW Status: APPROVED
Suite No: Applied Date: 01/30/2008
Applicant: SOUND TRANSIT Issue Date:
Receipt No.: R08 -01078
Payment Amount: $164.00
Initials: WER Payment Date: 04/08/2008 01:28 PM
User ID: 1655 Balance: $0.00
Payee: L K COMSTOCK
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 118901 164.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 164.00
Total: $164.00
rinc• Raraint -OA
Printari• 04- f1A -700A
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206-431 -3665
Web site: http: //www.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -00260
Initials: ]EM
User ID: 1165
Payee: MICHAEL BELLO
Payment Date: 01/30/2008
Total Payment: 123.00
SET ID: 0130 SET NAME: SOUND TRANSIT
SET TRANSACTIONS:
Set Member Amount
EL08 -093 41.00
EL08 -094 41.00
EL08 -095 41.00
TOTAL: 123.00
TRANSACTION LIST:
Type Method Description Amount
Payment Cash 123.00
TOTAL: 123.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.0 123.00
TOTAL: 123.00
7789 01/30 9710 TOTAL 123.00
Don: RECSFTS -OR
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION P'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: .
Co UM ) 4 f?N.� / 7
of Inspection: �y�
... .•) f... V
Ad /re�ssss:
%�(J(!� L7f
, l ('Date
74(er!"AL A`i� l
Called:
Special Instructions:
Date Wanted:
// 9/ 'V'
a:m
m.
Requester:
Phone No:
IJ•..
COM M ENTS:
EVrAEIMAffill
roved per applicable codes. Corrections required prior to approval. /
•
Inspecto
5/4 L orgai(,?'.`
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
t
INSPEIION NO.
INSPECTION RECORD
Retain a copy with permit
fiv5 -oyr
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
1
PERMIT NO.
(206)431 -3670
Project: 7 4
Q
!
Type of Inspection 70
0
A// !lI}f 97
"4/81, 4,D4e
Called:
Special Instructions: 6
1 re'
bate Wanted:
a.m.
p.m.
Requester:
(�
Phone No:
A proved per applicable codes. El Corrections required prior to approval.
OMMENTS:
7o 5/6-'8
Inspec
//I1' A /%/(,9/1 // (Date: 1///k hr
El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
8162299677 GE Transportation
Department of Labor and Industries
Factory Assembled Structures
PO Box 44430
Olympia WA 98504 -4430
ONE PERMIT PER FLOOR
08 :01:22 a.m. 03 -11 -2008 4 /4
FACTORY PERMIT
Do not complete shaded area
Permit
F 17
It># ?.......
Manufacturer No.
k4- S07
Manufacturer
MW
Contact Phone
Pat chafer
Phone
785- 232 -7792
Address Ci ty State Zip
3 ' 1 NW HWY 24 Topeka KS 66618
Please check the appropriate box indicating the type of floor (unit) to be inspected and list the serial number,
model number and plan approval number in the spaces provided.
❑ Commercial Coach
Factory Built Structures
❑ Temporary Worker Housing
❑ Vendor/ Medical Units
Serial No.
36929
Model No.
Plan Approval Number
03FBS0600254
L &I Department Use Only
FLOOR
COVER
VAPOR BARRIER
/9W\1
FINAL
) -30 -?7z)`(
Date Invoice #
FLOOR REIN.
COVER REIN.
— )7o — t s9 -?z23` r
Date Invoice #
— ?zz3
Date Invoice
Date Invoice #
Date Invoice #
INSUL REIN.
VB REIN.
FINAL REIN.
Date
Invoice #
REVIEWED FOR
DEC�. COMPLIANCE
NFPA
APR - 3 2008
Dat
Dat
Date
Date
Date Area Office Inspector f
1-11— - ie
Return to Central Office, MS 4430 within 3 working days after final inspection.
Invoice #
Invoice #
M ) r .
F623- 005 -000 factory permit 04-2004 White — Olympia Canary — Inspector Pink - Customer Goldenrod — Customer
INCOMPLETE fiO'b
LTR #� O1' �
Boeing Access
Nonvital Load Center
Device
Load (A)
per unit of
equipment
Total
quantity of
units
L1 Total load
(A)
L2 Total
load (A)
AC Circuit
Breaker
(A)
Heater (240V, 1500W)
6.25
1
3.13
3.13
20
HVAC /Fan motor
3.40
0`
15
Receptacles A wall
1.50
1
1.5
15
Receptacles C wall
1.50
4
6
20
Receptacles Entry
1.50
3
4.5
20
Fluorescent lights
0.25
4
1
15
Switch 1 Heaters
0.125
0
0
15
Switch 3 Heaters
0.125
0
0
15
Switch 5 Heaters
0.125
0
0
15
Switch 7 Heaters
0.125
0
0
15
ACPOKR (240V)
0.017
1
0.02
0.02
15
UPS (240V)
1
14.42
14.42
100
Total
26.06
_ 22.06
200
Yellow are the fields to be filled in
According to NEC - 220 -13 each receptacle draws 180VA (1.5A @ 120V)
Calculation utilizes the higher heater Toad only as fan and heaters are interlocked to prevent
simultaneous operation.
Boeing Access Location Summary
Nonvital Load Center
Total House
w
O
0_
0)
(D
o
N
(0
O
(o
N
co
O
N
N
Vital Load Center
Vital Main AC
U
1
U
rn
Et
0)
Y
(0
A)
03
0
O
O
N
Lci
0)
:t-z. 145
O V a3 Q
Q L U
C.5 m
0
N
O
N
to
•-
O
N
O
N
woo
•-
N
N
to
.-
to
•-
to
a-
to
o
a-
00
N
a
CO
N ...
J
CO
06
N
0
O
0
O
O
Ci
O
6
Q
co
O
=
a0
O
o
6
— co
N
M
.-6
M
co.
—00
O
O
0
cD
th
Load
coefficient/quantity
0.63
co
CD
0
op
NO0*
0
Q
0
•
•
-•
h
O
O
,-
O
Ne-
a-
10
00
Device
AF Power supply PRR 28 -36M (1TBO)
1 AF Power supply PRR 28 -36M (2TBO)
AF Power supply PRM 28 -17 (RBO)
Converter for Power frequency track circuits
O
y
L
_U
Alarm Panel
B12 power supply primary
B12 power supply redundant
N
009
N
O
Quantity of
interrogators
Total
AB switch
Communication equipment (W)
Maintenance computer (W)
LED signals (W)
TWC circuits (V -TAG & Modem)
c
co
E
E
0
U
Q
t6
7
E
O
N
-0
>,
O
0)
Y
t0
0)
0
y-'
U
U
U
. N
0
t0
0
to
N
a)
a)
a..
N
FE-
_C
U
N
a)
1
O
C
a)
t
U to
'O
LL w
+lap of Seattle, WA by MapQuest
Sorry! When printing directly from the browser your map may be incorrectly croppe4„,, To print the
ermit NO
entire map, try clicking the "Printer Friendly" link at the top of your results page. l`
F
Seattle, WA US
Page 1 of'
plar review" approval is subject to errors and omissions:
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of aP_Qroved. Field Copy and conditions is acknowlcriged
Sorry! When printing directly from the browser your map may be incorrectly crop ed. To prir}}rt,the ,,
entire map, try clicking the "Printer- Friendly" link at the top of your results pag�/'
5102nd :i',
SION
ay
0
n it
'teiEn
lassurrio74il4Ey
nse /co.p'right
esentation is made or warranty givenas to its c
r delay resulting from such use.
IpQu st iris
ntent. User aS
APR - 3 2008
p
HLE
Optic Works, Building Divisiof
PERMIT NI.Jlvli?E :
Appro
rjr .t AL.
7 NiAVTEQ or Tel Alias'
1 slt � ,.,m .r e4r'r51"r
1{ ° �. thnr t r�riffl1r r�{ C�1 �� ..1lf
es' (l nlW oft e• M�j� e? `St,arfdlts` SiJppliers
Ui;'An a IJ!I . inq Ivisior
NOTE: Revisions will require a new plan submits :? ! '
and may include additional plan review fees
$OE /A/G ACCESS SVGA/AL BUNGALOW
0°6
Ittp: / /www.mapquest .com/maps /map.adp ?formtype= address &addtohistory = &address = &city= seattle &state... 1 /1 7/200
Boeing Access
Nonvital Load Center
Device
Load (A)
per unit of
equipment
Total
quantity of
units
L1 Total load
(A)
L2 Total
load (A)
AC Circuit
Breaker
(A)
Heater (240V, 1500W)
6.25
1
3.13
3.13
20
HVAC /Fan motor
3.40 ,
0* '
15
Receptacles A wall
1.50
1
1.5
15
Receptacles C wall
1.50
4
6
20
Receptacles Entry
1.50
3
4.5
20
Fluorescent lights
0.25
4
1
15
Switch 1 Heaters
0.125
0
0
15
Switch 3 Heaters
0125.
0
0
15
Switch 5 Heaters
0.125
0 '
0
15
Switch 7 Heaters
0.125
0
0
15
ACPOKR (240V)
0.07
1
0.02
0.02
15
UPS (240V)
1'
14.42
14.42
100
Total
26.06
22.06
200.
Yellow are the fields to be filled in
According to NEC - 220 -13 each receptacle draws 180VA (1.5A @ 120V)
* Calculation utilizes the higher heater Toad only as fan and heaters are interlocked to prevent
simultaneous operation.
REVIEWED FOR
CODE COMPLIANCE
NFPA 70
APR - 3 2008
City Of Tukwila
B ILDIN DM ION
JAN 3 0
L
Boeing Access Location Summary
O • csi
w r
L
j Y
U � m
U 0 L
Q zm
E •5
• o
U
c9
O) Q
6N(�
J
w 2 La)
C'
t d
U 0
m
Z 0
U
< U
O
N
(0
(0
N
a;
C
a)
0
-o
a)
0
J
0
O
O
O
N
RE'VIEVVEpLIpNCE
CODE A��_NEC
NFP
APR - 3 2008
City -Of Tukwila
B _ILDIN DINT Is N
_CE.. , =0
cIT! .7 ?'
JAN 3 0
nr nr�
(��Iilv)I I GEN 1 LIn
0
0
1.6
141
0
0
0
0
CNI
Id)
0
co
N-
CO
0
0
CO
00
a)
0
0
0
co
co
co
(NI
0_
>,
0.
0.
a_
u_
0
c
(0
7
0.
(0.
0
0
0.
CV
cvis
00
c0
z <13
-C
.0
c0
•E'
E
0.
cr.
0)
c
*E
E
E
0
0
LC)
0.
E
c
a)
"0)
2
TWC circuits (V -TAG & Modem)
o
E
E
()
1.
0)
0.
E
8
REVIEWED FOR
DODE COMPLIANCE
w NFPA 70— NEC
APR — 3 2008
rry
JAN 3 0
L;Liv
09 -08 -2008
MICHAEL A BELLO
6533 3 AV S
SEATTLE WA 98108
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
RE: Permit No. EL08 -095
11001 EAST MARGINAL WY S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the
Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work
authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does
allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests
must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from
being taken.
In the event you do not call for the above inspection and receive an extension prior to 10/13/2008 , your permit will become null and
void and any further work on the project will require a new permit application and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
er Marshall
P'bm it Technician
xc:
Permit File No. ELO8 -095
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
February 28, 2008
•
Cizy of f 7'UkwZIcZ
•
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
Michael A. Bello
6533 Third Avenue South
Seattle, WA 98108
RE: Letter of Incomplete Application # 1
Electrical Permit Application EL08 -095
Sound Transit — 11001 East Marginal Way S
Dear Mr. Bello,
This letter is to inform you that your permit application received at the City of Tukwila Permit Center on
January 30, 2008 is determined to be incomplete. Before your application can continue the plan review
process the following item from the following department needs to be addressed:
Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning
the following comments.
1. Provide Labor and Industries inspection report for electrical.
Please address the comment above in an itemized format with applicable revised plans, specifications, and /or
other documentation. The City requires that three (3) sets of revised plans, specifications and/or other
documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I
have enclosed one for your convenience. Revisions must be made in person and will not be accepted
throufh the mail or by a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 431 -3670.
Sincerely,
14wik IDAY
Brenda Holt
Permit Coordinator
Enclosures
File: EL08 -095
P:\Permit Center\Incomplete Letters \2008 \ELO8 -095 Incomplete Ltr 11.DOC
wer
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
pERMIT COORD COPY �
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -095 DATE: 03 -13 -08
PROJECT NAME: SOUND TRANSIT
SITE ADDRESS: 1001 EAST MARGINAL WY S
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # After Permit Issued
DEPARTMENTS:
�'!Ir
Bui w g ision
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 03-18 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROU NG:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 04-15-08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -2H -02
• PERMIT COORD COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -095 DATE: 01 -30 -08
PROJECT NAME: SOUND TRANSIT
SITE ADDRESS: 11001 EAST MARGINAL WY S
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Buildirig D ision
Public Works
11-1-0-4
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete r J
Comments:
Incomplete
DUE DATE: 01-31-08
Not Applicable n
Permit Center Use Only /�
INCOMPLETE LETTER MAILED: `''O0) LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg Ed Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
[I
REVIEWER'S INITIALS:
Structural Review Required
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved 1 Approved with Conditions
Notation:
DUE DATE: 02 -28-08
Not Approved (attach comments)
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documentdrouting slip.doc
2 -28 -02
1
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http : / /www.cLtukvila.wa.u.s
1
REVISION SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: 3//2108'
Plan Check/Permit Number: EL00 -095
® Response to Incomplete Letter # 1
❑ Response to Correction Letter #
❑ Revision # ^after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
RECENED
CITY OPT: -,.. „A
MAR -■ ?pn8
Project Name: SOUND TRANSIT
Project Address: 11001 East Marginal Way S
Contact Person: Michael Bello Phone Number:
Summary of Revision:
ATIACHE/ L-440/2._ Qt /NDusT2 /ES /,cls ?6C770M /2-Ep027-
Sheet Number(s):
"Cloud” or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Permits Plus on O i((74 i' r'
\appIcations\forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Look Up a Contractor, Electriiiin or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
LKCOMCI312CR
Licensee Name
L K COMSTOCK & CO INC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
600045260
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
5 PENN PLAZA 12TH FLOOR
Address 2
City
NEW YORK
County
OUT OF STATE
State
NY
Zip
10001
Phone
2125027900
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
2/19/1969
Expiration Date
6/17/2008
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
ORCUTDD974PW
Master Electrician Information
License
ORCUTDD974PW
Name
ORCUTT, DOUGLAS D
Status
ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
AZARELA, MICHAEL R
01/01/1980
LARKIN, JOHN G
01/01/1980
MOORE, C WILLIAM
01/01/1980
GEORGE, KEITH
01/01/1980
•
Page 1 of 2
https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= LKCOMCI312CR 04/08/2008
A •
•
•
•
•
•
•
r
BOEING ACCESS
L & I GOLD SEAL APPROVAL NO. FBS43792
GENERATOR
PLUG
RATED
100A
>>-
FUSED
DISCONNECT
GND
NEU
L2
11
TO
GROUND GRID
VIA STRUCTURE
•
•
3 -1C 12
-1C 16
RATED
100A
DISTRIBUTION
PANEL
PERMITTED UNDER C755
PERMIT NO. /2ea9 /2E
1C 16
3 -1 C 82 (XHHW)
HOUSE LOAD
6.93 KVA
GND
NEU
L2
L1
TO
GROUND GRID
VIA STRUCTURE
GROUND GRID
NON -VITAL VIA STRUCTURE
LOAD CENTER
TRANSFER RATED
SWITCH 1"
1C 16
3 -1C /2
UPS LOAD
2.94 KW
GND
3 1C #2
1C #6
VITAL
LOAD CENTER
L
1
J
r
DISTRIBUTION
PANEL
PERMITTED ERMIT NO. /2809/2 E
133RD STREET
L & I GOLD SEAL APPROVAL. NO. F8S45651
GENERATOR FUSED
PLUG DISCONNECT
GND
RATED
100A
L
0
z
D
w
z
1C 86
3 1C /2(XHHW)
HOUSE LOAD
12.6 KVA
MAIN
0
NEU
3 -1C /9
NEU
L2
•
L1
1C /6
GND
NEU
L2
11
TO
GROUND GRID
VIA STRUCTURE
—3 -1C J2
—1C 16
RATED
100A
z
TO
7- GROUND GRID
NON -VITAL VIA STRUCTURE
LOAD CENTER
1
0
z
J
UPS
Z
z l7
TRANSFER RAC
SWITCH
4— 1C 16
3 -1C 12
UPS LOAD
10.8 KW
3 -1C 12
41— 1C d6
NQ
rj NEU
TO 1 CND ('.ITv ,,-'r=~?. ,.
GROUND GRID - ' I
VIA STRUCTURE VITAL
LOAD CENTER JAN 3 0 ;?:,,,-,3
[�4. L J
TFf'i1 ✓ii 1 Lv, l+; �
r
1
Designed By
KLW
A 10- 11- 07 ,KLW .SJS
SJS
AS SUBMITTED
No.
Dote
Dan. Chk.
APP.
Revisions
Drown By
Checked By
Approved By
SAT
SJS
GETS
Global Signaling
iii1111'
SOUNDTRANSIT
Scde:
NTS
Submitted:
Date:
Approved:
Dote:
Faename
0145SP0003.DWG
Contract No.:
RTA/LR95- 03/C802
Dote:
10 -11 -07
LINK LIGHT RAIL PROJECT
SIGNAL SYSTEM
SIGNAL POWER DISTRIBUTION
C755
BOEING ACCESS /133RD STREET
Drawing No.:
SPD -3
Sheet No.: Rev.:
003 A
•
2
•
A •
3
•
4
•
•
C •
• E • F • G • H
SIDE 'C"
/4 AWG BARE COPPER
7 BURIED IN EARTH A MINIMUM OF 18'
(INSTALLED BY FACIUTIES
CONTRACTOR)
NOTE 5.
/6 GRN
PRIME GROUND BUSS
SIDE "B'
DRAIN WIRE GROUND BUSS
NOTE 5.
. Y
6 FOOT /4 AWG GROUND PIGTAIL FROM STATION
GROUND OR GROUNDING RING THROUGH FOUNDATION
SLAB FOR CONNECTION TO BUNGALOW BUSS.
( INSTAUED BY FACIUTIES CONTRACTOR)
MTB
GROUND
DETECTORS
EQUIPMENT RACK
TYP
GRN FROM EACH RACK TO PRIME GROUND PLATE
/6 GRN TEST GROUND
#6GRN FROM EACH
LOAD CENTER TO
PRIME GROUND PLATE
NOTE 5. � f BARE
/6 BARE
COPPER I I I 1 1 COPPER
SIGNAL POWER HOUSE POWER
LOAD CENTER LOAD CENTER
Designee Bp
TT'
SIDE 'A'
MANUAL FUSED GENERATOR
RECEPTACLE
TRANSFER DISCONNECT UPS
SNATCH (GROUND TO BYPASS
STRUCTURE) SWITCH
'D"
1/2 — 13 SIUCON BRONZE
GROUNDING STUD LOCATED
ALL FOUR CORNERS.
B
D4 -10 -07
CRK
MAT
SJS
A )2- 06 —CO CRK MAT SJS
GETS
Global Signaling
NTS
Il :r�- irj
r -i-v - a
JAN 3 0:,:`s
Ft�ilrll 1 L•;;;j ' L$
NOTES:
1. AU. RACK — MOUNTED EQUIPMENT REQUIRING GROUNDING
WILL BE CONNECTED TO THE PRIME GROUND
PLATE VIA THE RACK GROUND STUD LOCATED
ON THE REAR OF EACH RACK.
2. EACH EQUIPMENT RACK 15 ISOLATED FROM
GROUND EXCEPT FOR THE GROUND WIRE
CONNECTION TO THE PRIME GROUND PLATE.
3 ALL UGHIING ARRESTORS MOUNTED CN THE MTB WI.L
BE CONNECTED TO THE PRIME GROUND PLATE AS
SHOWN ON THE TERMINAL BOARD LAY OUT DRAWINGS.
4. ALL HOUSE CIRCUITS WILL GROUND TO THE LOAD CENTER
GROUND BUSS WHICH IN TURN 15 CONNECTED TO A
GROUND STUD LOCATED ON THE FLOOR DIRECTLY
BELOW THE LOAD CENTER.
S. FLOOR GROUND STUD.
6.y4RE CHASE WILL GROUND TO THE HOUSE POWER LOAD
CENTER.
LINK LIGHT RAIL PROJECT
SIGNAL SYSTEM
BOEING ACCESS
Drawing No-
578-063
10' X 20' HOUSE GROUNDING ARRANGEMENT
8
1 ,•*".
Taf0—•`—
1
1 /
r!
1
T.kFt.
an
ro-
—
—./L--21E- • . .
/ Rr/7 R
:A ki t
ra
- - - ra• - - - - - - - - FO
•
A36
•
M v-32.02 (2-4)
)
x x_ 1/16A4 •
1-7
---r&Fc•
TeF0
rsco--- urn,
7.6:1r0-
Olme■••••,
j-A37
TE- 3208 (4-4)
SC-7533 (6-4)
C-7522 (6-4)
X
1661 Me 6161 EBB ISM EMI =I ME Mg BIM EfEl IMM 12222 MIM ISM 626I MO IBM MN 6216 MN gm
ar
7E-3202 (6-4)-'
STAIRWAY TO
AERIAL STRUCTURE
r
-TE - 3201 i )
MSS.-
FOUNCP •
1 x x X X
NOTES:
I. MANHOLE. DUCTBANK AND CONDUITS SHOWN -
FOR INFORMATION ONLY. WILL BE INSTALLED
BY CIVIL CONTRACTOR.
2. SIGNAL BUNGALOW FOUNDATION AND GROUNDING
WILL BE INSTALLED BY CIVIL CONTRACTOR.
x
x
x
x
x
\-MY-3201 (2-4;
x
DETAIL
SCALE: IN 5'
x
EVM UM MN MO MEI MN JIBE 6M1 Me MO WM
(3-2)
I
•
• SC-7521 (6-4)-N
SC MH -7517
157-0001
L57-G47 I
x
AUXILIARY
ELECTRICAL
CAB I NET
(N I C)
x
R.
SC-7542 (2-)
M FOUNDIr I ON
---SC-7523 (6
1
SIGNAL BUNGALOW
LOO-G I OgBOE INC ACCESS
riN\ s GNAL FOUNDATION
& GROUND I NG
LOO-G 100 L00-G100 hi ear
x
RECTIVr:D
CITY T. t, ,•.1A
JAN 3 0 ikisJ
P1-ibmi uti,j 1 Le3
5
0
5
ID
SCALE IN FEET
1
Designed 8%
R. DEMARTELAERE
.4 O. D. .
a
0,
4
,, ..
. ,,,, -''
—7— —
LV-750 I
( I -2)
.
__
157-0001
L57-G47 I
x
AUXILIARY
ELECTRICAL
CAB I NET
(N I C)
x
R.
SC-7542 (2-)
M FOUNDIr I ON
---SC-7523 (6
1
SIGNAL BUNGALOW
LOO-G I OgBOE INC ACCESS
riN\ s GNAL FOUNDATION
& GROUND I NG
LOO-G 100 L00-G100 hi ear
x
RECTIVr:D
CITY T. t, ,•.1A
JAN 3 0 ikisJ
P1-ibmi uti,j 1 Le3
5
0
5
ID
SCALE IN FEET
.
Designed 8%
R. DEMARTELAERE
.4 O. D. .
a
0,
4
,, ..
. ,,,, -''
LTE
Lik Engineedng Services
.
Wies
SouNDlivwsn-
soder
NTS
LINK L I GHT RAIL PROJECT
S I GNAL. SYSTEM • •
SIGNAL BUNGALOW . :
ENLARGED PLAN
BOEING ACCESS SITE
Drawing No.:
L57—GDO 1
,..-I
.
b
Drown Bx
8., PORTER
Flenern
C82_L57_GDOI.DWG
t
,
ri
•
Checked eis
L W I TTKOP
C .
olt/get No:
C 802
Sheet No.: Rev.:
274 L 0
i 0
10/14/04
ISSUED FOR CONSTRUCTION
Approved es
R. ABBOTT
Submitted
D. PORTER
Data
10
14
04
Approve ct
/ Data
R. PARSONS 10 14
04
Data
07/02/04
No.
Date
Dan.
Chk.
• •
Reons
Ltall....W101:13.11
ARCM
Oreivol
MmoAW
1
()SCALE •
r -r
•
3
•
4
•
5
1 20• (MAX)
PLUG• -1 N
PHOTO CONTROL
RELAY WITH
TAMPERPROOF .
CAGE
a
120V GFCI DUPLEX
RECEPTACLE WITH LOCKABLE,
WEATHERPROOF COVER
LEFT SIDE ELEVATION
36'
NOTE 2
'BRANCH CIRCUIT PANEL
AND.LIGHTING CONTROLS
C; =] GROUND BUS
f r-1rv�r-�
I 1 n' n n
"- - -T I
1
'4117.-----#1/0 BARE COPPER TO
GROUND RING
FRONT ELEVAT 1 ON
AUXILIARY ELECTRICAL CABINET (jr
SCALE 1 • = 11-0' L57-
t�r7 -dD20
¢4 STEEL REINFORCING BAR
• 12' OC EACH WAY
— 412 AWG BARE COPPER
BONDED TO REINFORCING
STEEL
n ELECTRICAL
DISTRIBUTION
CABINET
NOTES:
I. ELECTRICAL CABINET SHALL BE FABRICATED
FROM STAINLESS STEEL WITH
NON - DIRECTIONAL BRUSH PATTERN. ODOR
SHALL BE PADLOCKABLE WITH
-THREE -POINT LATCHES
2. FOR ELECTRICAL.ONE LINE DIAGRAM AND
BLOCK D I AGRAM SEE DETAILS 3 AND 4.
3. VERIFY LOCKOUT LOCATIONS WITH
CABINET MANUFACTURER.
4. PROVIDE A MANUAL SWITCH (LOCKABLE)
RATED FOR 480V. SQUARE D CLASS 2510
TYPE K OR APPROVED EQUAL
5. PROVIDE A 150 VA GENERAL PURPOSE
TRANSFORMER. 460/240V 10 PR I MARY W 1 TH
A 120V SECONDARY.
6. PROVIDE AND MOUNT A 12'x12•x6' DEEP
NEMA 12 ENCLOSURE WITH A HINGED DOOR.
MOUNT AND LABEL COMPONENTS.
7. CONNECT UNFUSED TRANSFORMER SECONDARY
LOAD TO THE MAIN GROUND CABLE IN THE
BEAM STRUCTURE.
34•x 10' COPPER-CLAD
L- ��GROUJD ROTS (TYP)
C R
A 10/09/06 KLY RME RME CNWD /126
. o 03/15/05L ISSUED FOR CONSTRUCTION
Aio. Date Dsn. CDk. App Rev6bna
SCHEMATIC DIAGRAM
SCALE NTS
Designed By
R. EACKER
Drown By:
B. PORTER
Checked By
M. BURNETT
Approved By
J DESANTO
L57-J008
LTIt
LTK Engineering Services
SCALE I • =
Suwratee t
E. ROWE
PANELBOARD
C LSERVICE CABINET 2
L57 -JD08
L57 -JD20 THRU JD23
LIGHTING
CONTRGLL
CABINET MOUNTED
PHOTO CONTROL
SEE SPECIFICATIONS
FOR REQUIREMENTS
NON - CONTROLLED CONTROLLED LIGHTING
BRANCH CIRCUITS BRANCH CIRCUITS
LIGHTING CONTROLLER BLOCK DIAGRAM
SCALE: NTS L57�
AvDroveQ
03/15/05 1
SoUNDTRANSIT
Dnte:
R. KEMPKES 03/15/05
Sale:
AS SHOWN
FHenome
S55_L57_JDOB.dwg
Controet No.:
C 755
Dote
09/1.3/04_
KTK 2 AMP
FUSE W/HOLDER
r
RECE;',';_ 0
OlTvCr.TI! . 111 `1
LJAN 3 10 2C08
FLHlvil•I (;EN I LR
1
1
1 ENCLOSURE
NOTE 6
L TI T2 1
MANUAL SWITCH
NOTE 4
TRANSFORMER
NOTE 5
NOTE 7
CCTV AND INTRUSION
DETECTOR POWER • CAB.I NET n
SCALE NTS LS\�
L57-.1P19, JP22
Drawing No.:
LINK LIGHT RA I-L PROJECT
SOUTH CORRIDOR
AUXILIARY ELECTRICAL
CABINET DETAILS
L57 —JDO8
Suet No.:
Rev.:
1420 A