HomeMy WebLinkAboutPermit EL08-0097 - RAINIER RUBBERRAINIER RUBBER 15660 NELSON PL EL08 -097 Parcel No.: Address: Suite No: CRAM' Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 0005800023 15660 NELSON PL TUKW ELECTRICAL PERMIT Permit Number: EL08 -097 Issue Date: 03/07/2008 Permit Expires On: 09/03/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: RAINIER RUBBER 15660 NELSON PL , TUKWILA WA MEYERS VERNON L 13911 SE 45TH PL , BELLEVUE WA DEAN HUMPHRIES 13301 SE 26 ST , BELLEVUE WA Contractor: Name: PRIME ELECTRIC INC Address: 13301 SE 26 ST , BELLEVUE WA Contractor License No: PRIMEEI134BT Phone: Phone: 425 747 -5200 Phone: 425 747 -5200 Expiration Date: 01/30/2009 DESCRIPTION OF WORK: INSTALL 200 AMP, 480 V SUBPANEL WITH 75 KVA TRANSFORMER. INSTALL 200 AMP 120/200 V PANEL. Value of Electrical: Type of Fire Protection: $15,000.00 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: (A) Fees Collected: National Electrical Code Edition: $410.00 2005 Date: 3- -U e I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presu construction or tl} pe o •■ ance of work. Signature: Print Name: give authority to violate or cancel the provisions of any other state or local laws regulating authorized to sign and obtain this electrical permit. DAN i //t_itfc Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -097 Printed: 03 -07 -2008 Parcel No.: 0005800023 Address: Suite No: Tenant: 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 15660 NELSON PL TUKW RAINIER RUBBER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -097 ISSUED 01/30/2008 03/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: �<-QC ci_ /A n i-iYf Date: doc: Cond -Elec EL08 -097 Printed: 03 -07 -2008 • • • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http:/Avww.ci.tukwila.wa.us Electrical Permit No. - Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: /5— 66,0 /lG6o,.. Tenant Name: King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes NI,. No =c10 — 0013 Property Owners Name: Mailing Address: City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: De ..., r%LtLKN 1r,1 es Day Telephone: 4/24— 7417- 5-200 Mailing Address: /S301 SE Z(o2 S{ Lf e getiL4 t %DQS City State Zip E -Mail Address: d L LA. FJ 431 ior; r• t P Co,,Wax Number: '/2S— — 747— TS ? ELECTRICAL CONTRACTOR INFORMATION Company Name: 2/i .si e 5 /eti,- c Mailing Address: /330/ 3e' 2(o l4 St aegtvw2 64 *tee - City State Zip Contact Person: - �nnGav� f% tii l J Day Telephone: Vl T 7 (47— 52c0 E -Mail Address: GY. J 'P7 - - c Fax Number: tfZ.5 - 7e17 - S-S1-2 Contractor Registration Number: Expiration Date: eco Valuation of Project (contractor's bid price): $ A570 Scope of Work (please provide detailed information): .s42,1Y ZDOsr_ pr S/fOv , S La/ 7S /NVA -fret44.54' rr+ e✓ . 2O0a,,, p X20/208 ✓ Pa •,.41 Will service be altered? cgf Yes ❑ No Type of Use: Ai Type of work: f/ ❑ New X Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? Yes ❑ No ❑ Service Change ❑ Fire Alarm ti \App hcanons\Fom s- Apphcaaons On Line \4 -2007 - Electrical Pemut Applicat on.doc bh ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 oft RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm. furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change S50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I IIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW T}IE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASIIINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 04/90 Print Name: .-ea,/ Day Telephone: yam= 74/7— .5-20 0 6"82; Mailing Address: /3 ?O/ 26' S{ .r3,e /4m.e. City IDate Application Accepted: /ti ` 10 I ; Date Application Expires: H \Applrcatrons\Forms- Applications On Law \4 -2007 - Electncal Pemat Application doc bh 9as State Zip Staff Initials: Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 0005800023 Permit Number: EL08 -097 Address: 15660 NELSON PL TUKW Status: PENDING Suite No: Applied Date: 01/30/2008 Applicant: RAINIER RUBBER Issue Date: Receipt No.: R08 -00263 Initials: User ID: Payee: JEM 1165 Payment Amount: $410.00 Payment Date: 01/30/2008 01:24 PM Balance: $0.00 PRIME ELECTRIC, INC. TRANSACTION LIST: Type Method Description Amount Payment Check 15934 410.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 328.00 000.345.832.00.0 82.00 Total: $410.00 7859 01/30 9710 TOTAL 410.00 doc: Receiot -06 Printed: 01 -30 -2008 INSPECTION RECORD Retain a copy with permit /JL INSPECTION NO. P ' IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: /' "SAM XI/ Type of Inspects n: / , Address : (; Date Called: Special Instructions: .f1 Date Wanted: //2 a.m. P.m. Requester: Phone No: p• oved per applicable codes. D Corrections required prior to approval. OMMENTS: Insp r: t t- ,uric G/1 Date 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Pr ect: gAIN/M 4/ & ?h'- Type of Inspection - 7001- Addis`) ivi, c dil oe.,/ Date Called: Special Instructions: Date Wanted: ..r- -5 /v. Requester: Phone No: roved per applicable codes. Corrections required prior to approval. OMMENTS: - owl 7A1 4-- 77) I/ / I ''///'rliE,l/T hirl-07-4.6/91./o// Date r /./U //a 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: P,. . Trend Report 12,004 w 750.0 r 700.0 I- 650.0 r 600.0 550.0 500 0 450 0 A 400.0 350.0 300.0 250.0 200.0 150.0 100.0 r 50.00 r 1 ttc10 v /11 Air Recording Start Date 12/4/2007 - 10:30:00 AM Recording Duration 6:20:30:00 (d:h:m:s) Instrument ID SDL A301 Serial 187335EKDV Firmware 3003 1.13 L L 1 1 12/4/2007 10:30:00.000 AM Name Date Time Ch2 Al2/4/200V10:30:00.000 AM Ch3 AI12/4/2007110:30:00.000 AM Ch1 A :12/4/2007.10:30:00.000 AM i r 1- 6:20:30:00 (D:H:M:S) 1 Days /Div Duration Units Avg Min Max Units 6:20:30:00 (D:H:M:S)1186.63 22.200 648.70 A 6:20:30:00 (D:H:M:S)1185 72'13.500 631.40 A 6:20:30:00 (D:H:M:S)L195.69 16.000 687.601 A 1 12/11/2007 7:00:00.000 AM A CPC's* G Name Date Time Duration Units Max Units Maxi 5MinuteAvg Ch1 A;12/10/200712:36:12.000 AM 15:00.00 (M:S) 360.20 A Maxl5MinuteAvg Ch3 A :12/10/2007 2:17:24.000PM- 15:00.0001 (M:S) 346.10 A :Maxl5MinuteAvg Ch2 A.12/10/2007 2:17:24.000 PM 15:00.0001 (M:S) 348.40, A 12/4/2007 - 10:30.00 000 AM Value 285.0 — Ch1 A 287 5 Ch2 A 279.5 -- Ch3 A X.XX — Maxl5MinuteAvg Ch1 A X.XX Maxl5MinuteAvg Ch2 A X.XX Maxl5MinuteAvg Ch3 A L..) A R�" CITY LA- FEB 2 9 2008 PERMIT CENTER Max15MbiUteAvg Chi A (A ) Date Time Avg 12/10/2007'2:36:12.000 AM1360.20 12/10/2007'2:51:12.000 AM '360.20 INCOMPLETE ILTR # —J- Trend Report --'?et € 450.0 400.0~ - - - -t4. 350.0E - -- I 300.0 - -- 1 A 250.0-- - 200.0 - -- 150.0 100.0 l� 2 . Recording Start Date 11/27/2007 - 8:30:00 AM Recording Duration 7:00.00:00 (d:h:m:s) Instrument ID SDL A301 Serial 187335EKDV Firmware 3003.1.13 J L L 50.00 0.000' 11/27/2007 8:30:00.000 AM 7:00:00:00 (D:H:M:S) 1 Days /Div Name Date Time Duration Units Avg Min Max Units Ch2 A.11/27/2007 8:30:00.000 AM 7:00:00:00! (D:H:M:S) 66.98911.5000 416.60 A Ch3 A:11/27/2007-8'30:00.000 AM 7:00:00:00' (D:H:M:S) 66.01711.5000 390.70 A Chi A.l1/27/2007 8.30:00.000 AM 7:00:00:00! (D:H:M:S) 69.94812.7000 427.80 A - Name Date Time Duration Units Max Units ' Maxl5MinuteAvg Ch3 A 12/3/2007 1:36:30.000 PM 15:00.000' (M.S),164.40 A 1 Maxl5MinuteAvg Ch1 Al2/3/2007 1:36:30.000 PM 15:00.000 (M:S) 167.40. Maxl5MinuteAvg Ch2 A.12/3/2007.1:36:42.000 PM,15:00.000 (M:S052.80, A 11/27/2007 - 8 30:00 000 AM Value 106.2 — Ch1 A 105.4 Ch2 A 100.6 — Ch3 A X.XX — Maxl5MinuteAvg Ch1 A X.XX - --- Maxl5MinuteAvg Ch2 A X.XX — Maxl5MinuteAvg Ch3 A W-ev- 11rt 1 C)LA 12/4/2007 8:30:00.000 AM Maxl5MinuteAvg Ch3 A (A) Date Time Avg 12/3/200711:36:30.000 PM 164.40 , 12/3/2007,1:51:30.000 PM' 164.40 1 Trend, 1 of 1 EXISTING PANEL H2 480V 3PH 3W 400 AMP MLO 1 PANEL HP2 200 A 60 AIR COMPRESSOR 2 3 PANEL HP2 200 B 60 AIR COMPRESSOR 4 5 PANEL HP2 200 C 60 AIR COMPRESSOR 6 7 PANEL C 150 A - 8 9 PANEL C 150 B - 10 11 PANEL C 150 C - 12 13 - A - 14 15 - B - 16 17 - C - 18 VA PHASE A - 29417.4 TOTAL VA - 86479.4 VA PHASE B - 29195.8 VA PHASE C - 27866.2 UTILITY NEW PANEL H2 -1 480V 3PH 3W 200 AMP MB 1 TRANSFORMER TX-1 90 A - LATHE MACHINE 2 3 TRANSFORMER TX-1 90 B - LATHE MACHINE 4 5 TRANSFORMER TX-1 90 C - LATHE MACHINE 6 7 MILL MACHINE -A A - 8 9 MILL MACHINE -B B - 10 11 MILL MACHINE - C - 12 13 - A - 14 15 - B - 16 17 - C - 18 VA PHASE A - 24930 VA-PHA =24930 REVISIONS VA PHASE C - 24930 No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ( EXISTING 480V/277V 3 PH, 4W 1200A SECTION 1 480V/277V 3 PH, 4W 1200A SECTION 2 TOTAL VA - 74790 #3/0 CU APPROVE- CAT a " : l a . ! R F-7— 77 ^. `a:GEC MODIFIED CR ALTERED WITHOUT AUTHORIZATION FPOM THE BUILDING 0"' ^: ?1L, AL'' WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS 1".:132.7.-.CT TO F: ?' C 'NSPEr..:TIOP:S PANEL H2 480V, 3 PH 3 WIRE 400 AMP MLO NEW 3" CONDUIT 3 — #3/0 CU 4" CONDUIT 4 -600 MCM CU PANEL H2 -1 480V, 3 PH 3 WIRE 200 AMP MB NEW PANEL L1 120/208V 3PH 4W 200 AMP MB 1 MILL MACHINE 40 A 20 LATHE MACHINE 2 3 MILL MACHINE 40 B 20 LATHE MACHINE 4 5 MILL MACHINE 40 C 20 LATHE MACHINE 6 7 MILL MACHINE 40 A - 8 9 MILL MACHINE 40 B - 10 11 MILL MACHINE 40 C - 12 13 - A - 14 15 - B - 16 17 - C - 18 VA PHASE A - 9600 TOTAL VA - 28800 VA PHASE B - 9600 VA PHASE C - 9600 SEPARATE PERMIT REQUIRED FOR: Mechanical ❑ Electrical Rif Plumbing 511 Gas Piping City of Tukwila BUILDING DIVISION NEW 2" CONDUIT 3 — #3/0 CU 1 — #4 GND 115' 75 kVA 1-1/4" CONDUIT 3 — #3 CU 1—#6 GND 20' CITY Ur I Unr FEB 2 9 2008 PERMIT CENTER (PRIME) ELECTRIC INC Electrical Construction Design & Service 425 - 747 -5200 Fermis N.,.01i)5 v47 Plar review approv Approval of con the violation of any N E111ot proved F By PANEL L1 Date: 120/208V 3 PH, 4 WIRE 200 AMP MB is subject to errors and orris documents does not mil opted code or ordinance. R and ditions is acknoW1E City of Tukwila BUILDING DIVISION 2" CONDUIT 3 — #3/0 CU 1—#4 GND 12' #6 GND INCOMPLETE LTR# Put& Works, Building Division PERMIT NUMBER IZa.;u atev- k�.b Tc�icr..� IG w A -061* FILE COPY February 28, 2008 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Dean Humphries 13301 SE 26t Street Bellevue, WA 98005 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -097 Rainier Rubber — 15660 Nelson Place Dear Mr. Humphries, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 30, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide complete 1 -line — show service etc. 2. Provide 30 -day meter reading on service or utility demand records for 1 year. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, ‘46e Brenda Holt Permit Coordinator Enclosures File: EL08 -097 P:U'ermit Center\Incomplete Letters\2008\EL08 -097 Incomplete Ltr # 1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 � PERMIT COORD COPY PLAN REVIEW /ROUTING SLOP ACTIVITY NUMBER: E1.08 -097 DATE: 02 -29 -08 PROJECT NAME: RAINIER RUBBER SITE ADDRESS: 15660 NELSON PL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: ��� Buil >: Dit�Psion Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Fr Incomplete n Comments: DUE DATE: 03-04 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW 111 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -01-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing sl ip.doc 2 -28 -02 M PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -097 DATE: 01 -30 -08 PROJECT NAME: RAINIER RUBBER SITE ADDRESS: 15660 NELSON PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bung D vi isionN wo6 Public Works n Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete J Incomplete DUE DATE: 01 -31 -08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: t'2$ 4f LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg e Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 1 Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 02 -28 -08 Approved n Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Wcb site: http : / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must he submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: VL 2\ 10% Plan ChecWPermit Number: EL08-097 ® Response to Incomplete Letter # 1 111 Response to Correction Letter # ❑ Revision # -after Permit is Issued ❑ Revision requested by a City Building inspector or Plans Examiner Project Name: RAINIER RUBBER goEIVCD CITY OF F'.JIM/ILA FEB 2 4 2n08 "F. Mi i GENTEF! Project Address: 15660 Nelson Place Contact Person: Dean Humphries Phone Number: g2_5"-- ,R6 V fg51676 7 Summary of Revision: c^ A (� oa-L9 S c ty, ., r c r-e c-0--119; K4 s ��/ I�/�(.�.�, 1� ✓ v I IV B y Gi wJ , C),(2 (.„'1409 A A H SA ✓ /?tc, L (fi udy, f-4 eeQa ✓ 5. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: ( Entered in Permits Plus on \ applications \forms - applications on Tine \revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electrician or Plumber License Detail 11111 • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License PRIMEEI134BT Licensee Name PRIME ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601004783 Ind. Ins. Account Id Business Type CORPORATION Address 1 13301 SE 26TH ST Address 2 City BELLEVUE County KING State WA Zip 98005 Phone 4257475200 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/30/1987 Expiration Date 1/30/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License TYRREWF973CK Master Electrician Information License TYRREWF973CK Name TYRRELL, WAYNE Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date TYRRELL, WAYNE F 01/01/1980 TYRELL, NANCY 01/01/1980 TYRELL, WAYNE AGENT 01/01/1980 1 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= PRIMEEI134BT 03/07/2008