Loading...
HomeMy WebLinkAboutPermit D06-043 - Stepping Stone Ventures #42 - Mobile HomeSTEPPING STONES VENTURES 14005 42 AV S D06 -043 Parcel No.: 1523049008 Address: 14005 42 AV S TUKW Suite No: Architect of Record: Name: - Address: , Phone: Engineer of Record: Name: - Address: , Phone: DESCRIPTION OF WORK: INSTALL AND SET UP OF MIBILE HOME doc: IBC - PERMIT City Ole Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: ci.tukwila.wa.us Tenant: Name: STEPPING STONE VENTURES Address: 14005 42 AV S, UNIT 42, TUKWILA WA Owner: Name: ANDERSON CARL AUGUST Address: 10212 NE 43RD, KIRKLAND WA 98033 Phone: Contact Person: Name: ERIN O'LEARY Address: 20303 10 AV W, LYNNWOOD WA 98036 Phone: 206 484 -3840 DEVELOPMENT PERMIT Contractor: Name: ESE CONSTRUCTION INC Address: 7189 F & S GRADE RD, SEDRO WOOLEY, WA 98284 Phone: Contractor License No: ESECOI *000RA * *continued on next page ** Permit Number: D06 -043 Issue Date: 03/16/2006 Permit Expires On: 09/12/2006 Expiration Date:12 /01/2007 Steven M. Mullet, Mayor Steve Lancaster, Director Value of Construction: $1,150.00 Fees Collected: $96.01 Type of Fire Protection: NONE Intemational Building Code Edition: 2003 Type of Construction: Occupancy per IBC: 0022 D06 -043 Printed: 03 -16 -2006 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N City tri Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206 -431 -3665 Web site: ct.tukwila.wa.us Permit Number: D06 -043 Issue Date: 03/16/2006 Permit Expires On: 09/12/2006 Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: N Hauling: N Start Time: End Time: Land Altering: N Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: 14 Moving Oversize Load: 14 Start Time: End Time: Sanitary Side Sewer: 14 Sewer Main Extension: N Private: Public: Storm Drainage: 14 Street Use: N Profit: N Non - Profit: 14 Water Main Extension: 14 Private: Public: Water Meter: N Permit Center Authorized Signature: I hereby certify that I have read and min his permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pe rmance of work. I am authorized to sign and obtain this development permit. Signature: Date: c /) (! / o� Print Name: J(+ ( c / el This permit shall become null and void If the work is not commenced within 180 days from the date of issuance, or if the work Is suspended or abandoned for a period of 180 days from the last Inspection. doc: IBC - PERMIT Steven M. Mullet, Mayor Steve Lancaster, Director Date: 0,711 6 006-043 Printed: 03-16-2006 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 Parcel No.: 1523049008 Address: 14005 42 AV $ TUKW Suite No: Tenant: STEPPING STONE VENTURES 1: ** *BUILDING DEPARTMENT CONDITIONS * ** PERMIT CONDITIONS Permit Number: D06 -043 Status: ISSUED Applied Date: 02/10/2006 Issue Date: 03/16/2006 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: AU permits, Inspection records, and approved plans shall be at the Job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All wood to remain in placed concrete shall be treated wood. 6: There shall be no occupancy of a building until final Inspection has been completed and approved by Tukwila building inspector. No exception. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Department of Public Health - Seattle and King County (206/296-4932). 8: All electrical work shall be inspected and approved under a separate permit issued by the Washington State Department of Labor and Industries (206/248- 6630). 9: VALIDITY OF PERMIT: The issuance or granting of a pemiit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The Issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors In the construction documents and other data. 10: ** *PLANNING DEPARTMENT CONDITIONS * ** 11: Manufactured home must be set back 5 feet from 5. 141st Street property line. * *continued on next page ** doc: Conditions 006-043 Printed: 03 -16 -2006 Signature: doc: Conditions Tukwila City of Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. / Print Name: 1" 1 n CY.L r � �VVf 1 Date: c3j 1(7 /® D06 -043 Printed: 03 -16 -2006 k t -' k'%, Pie Works Department x X Permit Center 1 6300 Southcenter Blvd., Suite 1o0 Tukwila, WA 98188 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print" Site Address: Iq o s. LW Ave,' S Tenant Name: Property Owners Name: CS4' 1) Mailing Address: r 2830 ' Company Name: Mailing Address: .ENCIN R EREC9 1 . kt2 .- dt ..i:" - 3j • Company Name: Mailing Address Vomits plaice k application (7.1000) 4 1 171 King Co Assessor's Tax No.: 1529/04 — 1,co Suite Number Floor. New Tenant: ❑ .. -. Yes ❑..No &'ak.C.- flu, X02 L.L& Ave, W Lyn /ILAW, Name: t i3 CY Lett t DayTelephone:PO&P ygq 3eHo Mailing Address: i l') ��� ( IOC`` Ave. (."-) I-th nwa WA b E-Mail Address: a biZfl 1 . g R.: Number 4S -rite, IO S illi [.tONTia i[tsli � k il sJl��" � Meihantoit tractOtiUfoisnathin O4La Company Name: ESI (ni.v&v/ ' 1 ( Al A L_ n (� f /.t f! 9$ �� Mailing Address: I R1 F S G rn to c ro COQ 4 Q C ryr (J ao� �f Contact Person: t�t:J� n t )a+ In r Day Telephone: i , (0{� CQ55 (0 - i o E-Mail Address: p - FaxNrmber: R 5 (c_ 3i5 Contractor Registration Number. FS Cot Ct)1� E Z T'C Expiration late: f -11 ...An original or mniriud copy ointment Washington State Contractor License must be presented at the .( e of permit issuance** rsa Contact Person: Day Telephone: E-Mail Address: Fax Number: mxtiiast $lechaptcal Peanut No.- iblic Works Permit No .Protect No lick. :` WA/A 9go3Ga Eagimet of.Rc&n State Sp ciy sure . 21p Contact Person: Day Telephone: E -Mail Address: Fax Number: Page 1 i Existing Interior Remodel Addition to Existing Structure New Type of Construction pa IBC Type of Occupancy Per IBC I Floor Y" Floor 3" Floor Floors duo Bamae+ 1 Accessory Structure Attached Garage Detached Garage Attached Carport . Detached Capon Covered Deck - .. Uncovered Deck BUILDING PERI4IITINFO MATION 4 2064314670 Valuation of Project (contractor's bid mice): S £ . rc) Existing Building Valuation: S cQ t n.r 0 Scope of Work (please provide detailed information): J D -1-4 I I SP 71'4 p rYlnint 1 A' 4- Pineal Will there be new rack storage? ❑ -Yes If "yes", see Handout No. for requirements. Provide All Building Areas In Square Footage Below PLANNING DMSIO Single - family building footprint (en ofdm arsdmao of smrcmrm plus eras dots ova 18 lot sod ovaharas grvaa diw' 1111 forbm) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling- Floor area for axessory dwelling: *Provide documentation entation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact Handicap: Will there be a change in use? ❑ —Yes ❑ _No lflyes °, explain: Far PROTECTION/HAZARDOUS M ATERIAL S_ 0.-Sprinklers 0-Automatic FireMarm -None ❑. Other (spedffy) Will there be storage or use of flammable, cwnbustible or materials in the building? ❑..Yess ❑ _No If yes'. attach list of materials and storage locations on a separate & //2 x It paper indicating quantities and Material Safety Data Sleets. ater District D_Tekwita ...WaterDistdct ❑_Water Availability P • Li-Right-of-way User- Nonprofit for lass than 72 haus ❑ -Right-of-way Use - No Disturbance ❑_ConslnniailExavatimWFin -Right-of -way Now Right- of-way - ❑ _Total Cut ❑ _Total Fill ❑_Sanitary Side Sewer 0-Cap or Remove Utilities ❑ -Frontage ❑-Traffic control ❑ ._Backflow Prevention - Fore Protection Irrigation Domestic Water cubic yards cubic yards ❑ _Permanent Water Meter size - . 0—Temporary Water Meter sine_ ❑ _Water Only Meter Sin B _Sewer Main EztExtension _ _Public -Water Main Extension — Public _ - Caf before you Dig: 1-800 -5555 ❑ _ Abandon Septic Tank ❑_cwbCut ❑ - Pavement taco ❑ _ looped Fee line WON WON WON Private Private ❑ - Work in Flood Zone ❑ _ Stone Drainage av PUBLIC -WORKS PERMIT ORMATION- 204=433 -0179 Scope of Wort (please provide detailed information)_ Please refer to Public Works Bulletin /1 for fees and estimate sham. ❑_Renton VaIVoe ❑ - Ramon ❑ _Seattle ❑ -Sewer Use Certificate Sewn Amiability Provided ❑- Approved Septic PlansProvided ❑ _. Sepdc System- For mite iigpicc system, provide 2 copies of a current septic design approval by King County Health Department- a6 c_url' - Plans (M m asimm Paper Size-22" z 34') ❑...Tedudat Into matian Report (Stem Drainage) ❑_.Bond ❑_Insurance ❑_Easanngs) ❑- Mat= Agmrmau(s) 0-Hold Harmless ❑ - Gwtedmial Report a_Traffie Impact Analysis ❑ - Rightof -way Ike -Profit for leas than 72 hours ❑ - Riga -of -dray elsz - Potential Disturbance ❑ - Crease Imaceptor ❑ _ (2,anndimtion ❑ _ Trench Excavation ❑ - Utility Uodagramding ❑_Datum Water Meter Sme___ EitionlliMithiaM Fire Lire Size at Property Line Number of Public Fire Hydrant) 0-Water 0-Sewer ❑._SewageTreatment MauhH savior: Blume m: Minn Day mdepbone Sore r Water Meter Refmd/Bliinc Nam= Day Tekphnac ?Milo& Address: Dar Sat TA Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furruice<100K Bit) Air Handling Unit >10,000 CFM Fire Damper 0-3 HP/100,000 ETU . Fumace>100K BTU Evaporator Cooler Dia= 3-15 HP/500,000 BTU Floor Furnace Ventilation Fan Conneaed to Single Duct Thamostat 15-30 HP/1,000,000 BTU Suspended/WalVFloor Mounted Heater VattilationSystan Wood/Gas Stove 30-50 HP/1,750,000 BTU Appliance Vent Hood and Duct Water Heater 50+ HP/I,750,000 BTU Repair or Addition to Heat/Retrig/Cooling System Incinerator - Domestic Emergency Generator Air Handling Unit <10,000 CFM Incinerator — Conunllnd Ma Medianical Equipment MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Cif Stale Zip Contact Person: Day Telephone E Address: Fax Number: Contractor Registration Number. Expiration Date: 'An original or notarized copy of current Washington State Contractor License must be presented at the time of permit issmuicen Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed infotmation) VAL: Residential: New ....0 Replacement-0 Commercial: New ....0 Replacement-0 Fuel Tyne: Electric.... Gas —.0 •Other: Indicate type of mechanical work being installed and the quantity below: Value of Contraction — In all can a value of construction antotmt should be entered by the applicant This figure will be reviewed and is subject to possible revision by the Permit Center to comply with =rent Sze schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon written request by the applicant as defined In Section 107.4 of the Uniform Balding Code (current edition). No application shall be extended more than once. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPUCATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF 114E STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ONVI,..3.0R AMIE ' b Ali Signature: ye - Print Name: E UV 0 e Day Telephone: i/qq34q maili Add ta 0 {Vie ki k..• AmetcP (A )1 60,360 ge rip I Date Application Accepted: 02 10' W Date Application Expires Staff Initials: 1 imalls *glee duseeeparai appiceioe (74004 % Page 4 Date: vi —103-0 RECEIPT NO: R06 -00351 Initials: JEM UserID: 1165 Payee: STEPPING STONE VENTURES, LLC SET ID: 0315 SET NAME: STEPPING STONES SET TRANSACTIONS: Set Member Amount D06 -042 59.96 006 -043 59.96 D06 -044 59.96 D06 -045 59.96 D06 -046 59.96 D06 -047 59.96 D06 -048 59.96 D06 - 049 59.96 D06 -050 59.96 D06 -051 59.96 D06 -052 59.96 TOTAL: 659.56 TRANSACTION LIST: Type Method Description Payment Check 6064 659.56 TOTAL: 659.56 ACCOUNT ITEM LIST: Description BUILDING - RES STATE BUILDING SURCHARGE City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431 -3670 Fax: 206 -431 -3665 SET RECEIPT Payment Date: 03/16/2006 Total Payment:659.56 Amount Account code Current Pmts 000/322.100 610.06 000/386.904 49.50 TOTAL: 659.56 Steven M. Mullet, Mavor Steve Lancaster, Director 3621 03/16 9716 TOTAL 659.56 C AT T11 �IW Steven M. Mullet Mavor Department of Community Development Sieve Lancaster, Director 6300 Southcenter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431 -3665 SET RECEIPT Copy Reprinted on 02 -10 -2006 at 14:28:20 02/10/2006 RECEIPT NO: R06 -00200 Initials: JEM User ID: 1165 Payee: STEPPING STONE VENTURES, LLC SET ID: 021006 SET NAME: STEPPING STONE VENTURES SET TRANSACTIONS: Set Member Amount D06 -042 D06 -043 D06 -044 D06 -045 D06 -046 D06 -047 D06 -048 D06 -049 D06 -050 D06 -051 D06 -052 TOTAL: 36.05 36.05 36.05 36.05 36.05 36.05 36.05 36.05 36.05 36.05 36.05 396.55 TRANSACTION LIST: Type Method Description Amount Payment Check 6035 ACCOUNT ITEM LIST: Description PLAN CHECK - RES TOTAL: Payment Date: 02/10/2006 Total Payment: 396.55 396.55 396.55 Account Code Current Pmts 000/345.830 TOTAL: 396.55 396.55 2348 02/10 9716 TOTAL 396.55 P I S c 1 4g 7 di_ 12;/7 ..3 AAP' Type of Inspection: / C / A, fr, / \,. Address: /90a5 4 S Date Called: Special Instructions: Date Wanted: a.m. Pm. Requester: Phone No: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERM (206)431-36 0 COMMENTS: Se1/43. 4. Approved per applicable codes. Corrections required prior to approval. .00 REINSPECTION C E REQ !RED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. 'Receipt No.: 'Date: * -, ^ Pr�o c1• - - 2 /e' J, ,Slinr Type of Inspection: / /F ()Oct) , I l Addr s: � S / yZ Date Called: Special LIT Date Wanted: a.m. /3- 0 7 G ltequ 2t toy— 2s vv pproved per applicable codes. Corrections required prior to approval. OMMENTS: ezti.:vvii. 1 l' 'Date _ / 3 -- 7 : .00 REINSPECTIO FEE REQUIRE Prior o inspection. fee must be m INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 eipt No.: 'Date: PER 1 -3670 City of Tukwila Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670 PERMIT INSPECTIONS Parcel No.: 1523049008 Permit Number: D06 -043 Address: 14005 42 AV S TUKW Status: FINAL Suite No: Applied Date: 02/10/2006 Tenant: STEPPING STONE VENTURES Issue Date: 03/16/2006 Description: INSTALL AND SET UP OF MOBILE HOME Item: 00203 TIEDOWN - MOBILE HOMES 07/13/2007 By: JD Action: AP Comments: APPROVED/ #1 Item: 01700 FINAL - BUILDING 07/27/2007 By: JD Action: AP Comments: APPROVED / #2 doc: Inspections 006 -043 Printed: 08 -30 -2007 Ml nuts Man 7th'- :'I`ak1D 1.1 :173 I'L Pacific Consulting Engineers September 21, 2005 Mr. Scott Morena Minute Man Products, Inc. 305 West King Street Fast Fla( Rack NC 28726 2150 Hell An., Salle 145 • Seeram•nto, CA 9930 • (916) 3646028 • Fax; (910) 5646029 RE: State of Washington Engineer's seal Dear Scott; 828 682 0268 neaaff David A. Dabmcn P.E. P' 08/22/06 081 Seam P. 002 'AO.>OVOGCJ r.n, Please be advised my Washington Engineer's license has been renewed to 7/17/07. 1 have stamped and signed by seal on this letter. I have re- sealed the Engineered Tie Down plan and details with the updated WA seal and have mailed the plans to you for Your use- Sincerely FILE COPY Of 1llkwlla RIM 1Nt nnvgTnhi Amami) roar O M P L E T E CRYOFTUKWILA LTR # �� MAR 102006 ,`.,CORRECTION PERMIT CENTS, LTR# # _..("_ 1 Minute Men DESIGN WADS: • WIND - 15PSF• • • SOIL BEARING 1000 PSF • TIE DOWN STRAP - 3150# WORKING LOAD • SEISMIC ZONE 4 TIC 71 EMSTRAPS TO BE MIN. 1 1/4" WIDE X 0035 THICKNESS ZNC PLATED AND MEET ASTM D395391 • • EARTH AUGERS 29629 MIN. (TESTED TO 475C# MIN.) • CROSS DRIVES 1727# ((CALCULATED) • CONCRETE SLAB ANCHORS 1390# (CALCULATED) GENERAL NOTE& 1 THE CHARTS SHOWN HEREIN ARE FOR THE REQUIRED NUMBER OF TIE DOWNS DN THE SIDES OF THE MANUFACTURED HOME. 2 TIE DOWNS ARE REQUIRED AT EACH CHASSIS BEAM, EACH END OF EACH TRANSPORTABLE SECTION OF THg MANUFACTURED HOME AND CAN BE ANY `OF THE TYPES6HOWN HEREIN. 3.� QQMBI TX S OF THE DIFFERENT TYPES OF TIE DOWNS CAN BE USED. 4.L'IP)'tHEIAN EARTH AUGER CANNOT BE INSTALLED DUE TO AN OBSTRUCTION, USE OF CROSS DRIVE ANCHORS IS PERMfTTEO, PROVIDED (2) CROSS ORIVES ARE IN FOR EACH EARTH AUGER THAT CANNOT BE INSTALLED. - 5.4F.OR ALMA DOWN INSTALLATIONS, THE MFGD HOME CHASSIS MEMBERS ARE SHOWN AS BEAMS. FOR ILLUSTRATION PURPOSES ONLY. CHASSIS BEAMS (,1i Iir f54N'ALEO SitiSIiAPED OR "RFC" SHAPED. 6. END TIE DOWNS CAN BE LOCATED WITHIN 24" OF EITHER SIDE OF CHASSIS BEAM NOS AS SHOWN. ✓ 7. THE SIZES, TYPES, LENGTHS, ECT.OF MATERIALSHOWN HEREIN ARE MINIMUM. LARGER, LONGER, HEAVIER MATERIALS SUPPLED BY MINUTE -MAN PRODUCTS, MAY BE USED AT THE SAME SPACING & LOCATION SHOWN. 8. ALL. PARTS ARE STAMPED MMA- WITH THE APPROPRIATE PART NUMBER. 9. THIS TIE DOWN SYSTEM CAN BE USED WITH 10' WIDE MANUFACTURED HOME SECTIONS WITH 100" CHASSIS CENTERS PROVIDED THE HEIGHT FROM GRADE TO THE BOTTOM OF THE CHASSIS BEAM DOES NOT EXCEED 19". 111 TIE DOWN STRAPS IN THE LONGITCIDINAL OR TRANSVERSE DIRECTION CAN BE BOLTED TO THE HITCH ATTACHMEN) PLATE THAT IS WELDED TO THE CHASSIS BEAM; r.r1- 11 ^rF ' : r 5 1.0 1 PO 929 892 0258 - 09.'Z210S 091SBam P 009 MINUTE MAN ANCHORS, INC. E� FLATROOCE, NG -• PH: (800 438 -7277 ENGINEERED TICE DOWN SYSTEM DESIGN & GENERAL NOTES • m 7/ 07 Minut. Man 828 892 0268 DX Am SHOWN. TIE • - 'q'AFC ".PAST 'CR CVO '•E DOWN CJ.MCC }IONS '— M VI -4 -I NC4636, EZDH & MMA34 EARTH AUGER TIE DOWN - r f POI T2 DOWN AT CALL OF [tAn, MULL 1/r Ax7 BOLT. STC0. SFRA/ SErYOCAY CRAMS FOR TIE DOWN ANCHOR N C W BEAM CHASSIS 1 IA 434 MMWC 11C STABILIZER Putt 01111 e/1r mac 4 MID MIGHT ICAK n a T/r Asb7 COL[ -1 STCCL r" In = V&CM . RFC` BEAM CHASSIS INSTALLATION INSTRUCTIONS 09/22/05 08,68am P. 004 -IIGAM MOWN. WCe 'a 2 Wan SIS tort mo SIC born CONNtCTIOPs N ant ED E m Cown - EARTH AUGER TIE DOWN 1. THE DRIVE MACHINE IS STARTED AND THE ANCHOR IS TURNED INTO THE GROUND TO A POINT WHERE THE TOP (STABILIZER HEAD PLATE) IS PLUSH OR SLIGHTLY BELOW GROUND LEVEL THIS INSURES THAT THE E'ZANCHOR STABILIZER WILL BE AT ITS REQUIRED INSTALLATION POSITION, , 2. FOR THE E-Z ANCHOR/STABILIZER TO ACHIEVE FULL POTENTIAL, INSTALL THE ANCHOR VERTICALLY WITH NO DEVIATION GREATER THAN 10 DEGREES. NOTE: A SLIGHTLY GREATER ANGLE MAY BE USED TO START THE ANCHOR TO AVOID CONTACT WITH THE HOME & STRAIGHTENED AS THE ANCHOR IS GROUND SET. THE SPLIT BOLT IS INSERTED, STRAP FASTENED, AND TIGHTENING ADJUSTMENT MADE NOTE: WITH MACHINE INSTALLATION, A MINUTE -MAN ADAPTER DESIGNED TO FIT BOTH THE ANCHOR HEAD AND DRIVE MACHINE SHAFT IS AVAILABLE, INSTALLERS DO NOT NEED ADDITIONAL OR SPECIAL EQUIPMENT FOR CZ ANCHOR INSTALLATION. • NOTE: AN ADDITIONAL STABILIZER PLATE IS NOT REQUIRED WITH EZDH & GW2 EARTH AUGER TIE DOWN. CONCRETE TIE DOWN CROSS DRIVE TIE DOWN DHnsSiS -� trAr IDWH, etc E NO T ( SI GOWN CONNWCOe6 1 ,0/461 4 • ta I SAES SO LT It NUT CROSS sTAWILI r O ANCHOR ' „ ► MAC t CR9S5 DRIVE w/ sT45ILVrR PI ATr nE-rMP Minute Man 828 692 0258 FIRST CHECK FOR UNDERGROUND UTILITY LOCATION: EZDH EARTH AUGERS 1. SEE DETAIL THIS BOOKLET FOR INSTALLATION INSTRUCTIONS. EARTH AUGERS 1. INSTALL AUGERS INTO SOIL WITH CONSTANT DOWNWARD PRESSURE TO MINIMIZE SON. DISTURBANCE LEAVING APPROX. 12" OF SHAFT EXPOSED. 2. INSTALL STABILZER PLATE - DRIVE FLUSH WITH GROUND SURFACE. 3. COMPLETE TURNING AUGER INTO GROUND UNTIL AUGER HEAD IS FLUSH WITH GROUND SURFACE AND TOP OF STABILIZER PLATE. CROSS DRIVE ANCHORS 1. CROSS DRIVES ARE USED WHERE HARD ROCKY SON_ OCCURS. IF THE GROUND SURFACE IS OTHER THAN ROCK OR MINIMUM 2' ASPHALT, INSTALL MMA -SD2 STABILZER PLATE, OR PLACE 121(12102" DEEP CONCRETE CONCRETE SLAB ANCHORS 1. CONCRETE SLAB TO BE MINIMUM 31/2' THICK AND IN GOOD CONDITION. 2. MINIMUM SLAB AREA REQUIRED FOR EACH ANCHOR IS 28 SO. FEET. • 3. DRILL PROPER SIZE HOLE IN SLAB MINIMUM 12" FROM ANY EDGE ALL APPLICATIONS 1. ATTACH ACH STRAPS TO CHASSIS BEAM IN MANNER SHOWN. 2. INSERT STRAP THROUGH SPLIT NUT, CUT OFF EXCESS STRAP AND TIGHTEN UNTIL. SNUG. CND S T TIC DOWNS EE SINGLE WIDE INSTALLATION INSTRUCTIONS TIE DOWN LOCATIONS EARTH AUGERS I CROSS DRIVE max HIE roio 1 W17 '2}3I4I 32 SINE Ma OF= TI6DCMfs 3 ANCHORS 42 162) 52 1 OP 13 CONCRETE SIAS ANCHORS , ¢oowRs 5 18 4 5 7 1 rR iTO nero6 B NOTE: IF OBSTRUCTIONS PRECLUDE THE PLACEMENT OF THE SIDE TIE DOWNS AT THE 2' LOCATION SHOWN SIDE TIE DOWNS AT 24' FROM EACH END HAVE A TOLERANCE OF 1 t ---I I-' 1/3“ MIN. t0 TO IS SEE MART DOUBLE WIDE SOLT at TOP PER 09/22/05 08:S8am P. 005 CC TIC OTT*TA !EC 1 I M ty TRIPLE WIDE .wcdo* END TIE DOWN N NOTE; TIE DOWN STRAPS ATTHE CHASSIS BEAM ENDS , TEND TIE DOWNS) CAN BE ATTACHED TO A CHASSIS CD - SuFPORT PIER WITH A PIER BOLT ON TOP. (SEE SKETCH ABOVE). Q Minute Man TLW 01 -03 MMA'a02 STABILIZER PLATE STABILIZATION PLATE WELDED TO ROD GUIDE B STRAP HEAD 626 B92 0256 NC4538 7/8 DIA 38"AUOER ANCHOR AZTEX ANCHOR MMA -35 CROSS DRIVE ANCHOR CROSS ORNE ANCHOR W/ 3/4'4x32' RODS W/ 23/32 RODS MMA SPUT BOLT & NUT MMA -21EUDH MNA•210POH (�,, STABILIZER CAP 't'J CO DISSK 0 u •� 4:10 I4 s) Ii L I I L r/ T MMA -TB CONCRETE CHR U8 LASE OUT9DE Hats ADR - 4• TIAHOEs MMA - 5/5 DIA MMA •92 3/4 DIA MMA -94 3/4 DIA 32 "aLutR ANCHOR 32'AUCER ANCHOR 36 AUGER ANCHOR DOTTOU PLATE MMA-•34 LONCRUDIM4L FRAME TIE AND CLAMP (rcR WIND ZONE 1) MMA 8 3/4 0H 4430 NU 3/4 TD'.JrafW+ no +eowI r. ...... MM 32 STEEL STRAP w /BUCKEL oP D TOP PLATE MMA -34 BOTTOM PLATE MMA -II STEEL $TRAP w /COR Y NER TIE TOP PLATE 0 0 1, O I alt ecw ! LASE RIS70E NOLLS FOR r - r FIANCES 4- ode GAVE e iMQmC DOLTS e -A• S RICH SWEHGTH WASHER � 1 MW 71 CORNS? RC a RAP Maus CLIP ONts COW TO MMA .-650 3/4 DIA 4430 0m 3/ OIA 50 ANCHOR 30 AUGER ANCHOR HOR NE ROO v 114 C ESE Construction Inc. i 7189 F&S Grade Rd. Sedro Wooiey, Wa. 9828428 e 360-708-3599 c 360-8684345 fax 1105 $ I c i WAINS ESECOI'°OOORA 12105 o An State approved tie downs every 11' on center Ron Soini 4 1 resident 1 ;- t o red home 12'114'116' wide to 70' long Manufactured Home Main Beam in Typical blocking and tie down installation to Washington state code 8x8x16 hollow concrete blocks set on 2 ea, 4x4x8 solid concrete blocks (pad) Or state approved metal stands on pads with wood shimes and wedges.. Foundation pier blocking.8' center to 12' center RECEIVED CITY OF TUKWILA FEB 2 3 2006 PERMIT CENTEn Perimeter block at every door and window larger than 48" RECEIVED CITY OF TU FEB 23 PEHiwi I GEN MATERIALS CALCULATIONS CfEiU fC1:3Cflt E3C g T g Q t a r ctive Me in s ted cen num w ProG uard' r 7 tf»ure %v ventee s :o install 4 Lifetime Warranty c Cgc - I1 -OR U nS ViAy '4 w it. - 4r. White 02 -02 -2007 ERIN O'LEARY 20303 10 AV W LYNNWOOD WA 98036 RE: Permit No. D06-043 14005 42 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted pernit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be br wrltiut and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/11/2007 , your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: Permit File No. D06-043 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206-431-3665 07 -28 -2006 ERIN O'LEARY 20303 10 AV W LYNNWOOD WA 98036 RE: Permit No. D06 -043 14005 42 AV S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for additional periods not exceeding 90 days each. Extension requests must be In writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 09/12/2006, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, rshall, Permit - ician XC: Permit File No. D06-043 City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite 1!100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206- 431 -3665 March 23, 2007 Erin O'Leary Stepping Stone Ventures, LLC 20303 10 Av W Lynnwood, WA 98036 RE: Request for Extension #2 Development Permit No. D06 -042 through 052 & D06 -105 Stepping Stone Ventures —14005 42 Av S Dear Erin: This letter is in response to your written request for an extension to Permit Nos. D06 -042 through 052 and D06 -105. The City of Tukwila Building Division will be extending the expiration dates of your permits for an additional 180 days. Consequently, permits D06-042 through D06 -052 will be extended through September 07, 2007 and permit D06 -105 will be extended through September 25, 2007. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, File: Permit No. D06 -042 through 052 & D06 -105 P:Vennif r%Extension Letterswemuts■2006'D06-042 -052 & 105 Permit Extension #2.doc Page 1 of l jem rshall it'Tedlmician City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206- 431 -3665 March 9, 2007 Jennifer Marshall City of Tukwila 6300 Southcenter Boulevard Suite #100 Tukwila Washington 98188 RE: Request for Extension on Permits Dear Jennifer Marshall: I am writing you to request an extension on the following (11) permits: D06 -042 043 044 045 046 048 049 050 051 052 105 The request is asked due to the time it has taken to finalize the necessary electrical upgrades with Seattle City Light. Please accept our request for the extension on these permits Sincerely, Erin 'Leary Stepping Stone Ventures, LLC dba Southgate Mobile Home Park 07-411 104- fol2-OZ si chi2q1A. CA- 4174- thole- all Atikee-4 fifra 03 -12-0 RECENED CCTV OF Y. n.•tirn A MAR 0 9 2007 CENTER September 15, 2006 Erin O'Leary Stepping Stone Ventures, LLC 20303 10 Av W Lynnwood, WA 98036 City of Tukwila Department of Community Development Steve Lancaster, Director RE: Request for Extension Development Permit No. D06 -042 through 052 & D06 -105 Stepping Stone Ventures —14005 42 Av S Dear Erin. This letter is in response to your written request for an extension to Permit Nos. D06 -042 through 052 and D06 -105. The City of Tukwila Building Division will be extending the expiration dates of your permits for an additional 180 days. Consequently, permits D06 -042 through D06 -052 will be extended through March 11, 2007 and permit D06 -105 will be extended through March 29, 2007. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely arshall unit l hnician Mali File: Permit No. D06 -042 through 052 & D06 -105 PNenniferkExtemion Let ters\PennitslW6042 -052 & 105 Permit Extension.4a Page 1 of I jem Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 -431 -3665 oI Kt to S(TEND tea vais 0`l- 15-01, September 8, 2006 Jennifer Marshall City of Tukwila 6300 Southcenter Boulevard Suite #100 Tukwila Washington 98188 RE: Request for Extension on Permits Dear Jennifer Marshall: I am writing you to request an extension on the following (13) permits: Exe safe oe - 25-o7 Nor etreNo A•r TMi4 t'iME Oat - lt-O( \ n I D06 -015 042 043 044 045 046 047 048 049 050 051 052 105 Sincerely, ti The request is asked due to an extended period of time it took to complete financing that was required to move forward with the above referenced permit numbers. Please accept our request for our first extension on these permits. We are looking forward to beginning our work within the next week. u 09 -3o -o& • -1.07) Erin O'Leary Stepping Stone dba Southgate Mo oa -i2 -O4 I•t?q) es, LLC ome Park RECEIVED CITY OF TUKWI A SEP 0 8 2008 PERMIT CENTER March 2, 2006 Erin O'Leary 20303 10 Av W Lynnwood, WA 98036 City of Tukwila Dear Ms. O'Leary: Department of Community Development Steve Lancaster, Director RE: Letter of Incomplete Application # 1 to Correction Letter #1 Development Permit Application D06 -042 through 052 Stepping Stone Ventures —14005 42 Av S (Units 35, 36, 38, 39, 40, 41, 42, 43, 44, 46, 58) This letter is to inform you that your resubmittal received at the City of Tukwila Permit Center on February 23, 2006 is determined to be incomplete. Before your application can continue the plan review process the attached items from the following department(s) need to be addressed: Building Department: Allen Johannessen, at 206 433 -7163, if you have any questions concerning comment below. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenzer service. If you have any questions, please contact me at the Permit Center at (206) 433 - 7165. Sincerely, Enclosures 4 ikaA�IINI.r hall clan File: Permit D06 -042 through 052 P:Vennifer\Incomplete Letters\2006\D06 -042 through 052 Inc Ltr #1 to Corr #I.DOC Steven M. Mullet, Mayor 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 Determination of Completeness Memo Tukwila Building Division Allen Johannessen, Plan Examiner Date: February 28, 2006 Project Name: Stepping Stone Ventures Permit #: D06-042, 043, 044, 045, 046, 047, 048, 049, 050, 051 and 052 Plan Review: Allen Johannessen, Plans Examiner A Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (Drawing and structural calculations sheets shall be original signed wet stamp not copied.) — Please address all comments per previous letter dated February 21.2006. 1 Provide details for each individual mobile home installation that shall show the following items as recommended by the manufacture. (Not the contractor) a) Show the recommended spacing and construction method for the support blocking. (By the manufacture) b) Show the recommended method of tie downs with details and hardware specifications. (By the manufacture) c) Show skirting details as recommended by the manufacture. Sheets that were submitted are not clear and legible. Provide sheets that are legible. 2 Provide setback dimensions on the site plan that meet setback requirements. Setbacks for that location are 6 feet. Show the appropriate setbacks on the plans. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. February 22, 2006 Erin O'Leary 20303 10 Av W Lynnwood, WA 98036 RE: CORRECTION LETTER #1 Development Permit Application Number D06 -042 through 052 Stepping Stone Ventures —14005 42 Av S (Units 35, 36, 38, 39, 40, 41, 42, 43, 44, 46, 58) Dear Ms. O'Leary: City of Tukwila Steven M. Mullet, Mayor Department of Community Development Steve Lancaster, Director This letter is to inform you of corrections that must be addressed before your development permit(s) can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Allen Johannessen, at 206 433 -7163, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) complete sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mall or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely l: encl arshall echnician xc: File No. D06 -042 through 052 P:Vennifer\Correction Letters \2006 \D06.042 Ono 052 Correction Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206-431-3670 • Fax: 206- 431 -3665 Building Division Review Memo Tukwila Building Division Allen Johannessen, Plan Examiner Date: February 21, 2006 Protect Name: Stepping Stone Ventures Permit #: D06- 042, 043, 044, 045, 046, 047, 048, 049, 050, 051 and 052 Plan Review: Allen Johannessen, Plans Examiner A Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (Drawing and structural calculations sheets shall be original signed wet stamp not copied.) 1 Provide details for each individual mobile home installation that shall show the following items as recommended by the manufacture. a) Show the recommended spacing and construction method for the support blocking. b) Show the recommended method of fie downs with details and hardware specifications. c) Show skirting details as recommended by the manufacture. 2 Provide setback dimensions on the site plan that meet setback requirements. Should there be questions concerning the above requirements, contact the Building Division at 206431- 3670. No further comments at this lime. itiorPERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: 006 -043 DATE: 03 -10 -06 PROJECT NAME: STEPPING STONE VENTURES SITE ADDRESS: 14005 42 AV S, UNIT 42 X Response to Incomplete Letter # 1 Revision # After Permit Issued Original Plan Submittal X Response to Correction Letter # 1 DEPARTMENTS: Bui :'3 g Division Comments: Documents/touting slip.doc 2 -28-02 Fire Prevention DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Ft Incomplete ❑ TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DATE: Planning Division Public Works ❑ Structural ❑ Permit Coordinator No further Review Required DUE DATE: 03-14-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: DUE DATE: 04 -11 -06 Not Approved (attach comments) ❑ Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: ACTIVITY NUMBER: D06 -043 DATE: 02 -23 -06 PROJECT NAME: STEPPING STONE VENTURES SITE ADDRESS: 14005 42 AV S, UNIT 42 Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 8-1 Public Works vision WO& DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Comments: TUES/THURS ROUTING: Please Route ❑ Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPY '" PLAN REVIEW /ROUTING SLIP Fire Prevention Structural Incomplete DATE: DATE: Planning Division Permit Coordinator DUE DATE: 02 -28-06 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: At DI. • c p LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:` No further Review Required DUE DATE: 03-28-06 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: PERMIT COORD COPY` - PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D06 - 043 PROJECT NAME: SITE ADDRESS: X Original Plan Submittal Response to Correction Letter # STEPPING STONE VENTURES 14005 42 AV S, UNIT 42 DATE: 02 -10 -06 Response to Incomplete Letter # Revision # After Permit Issued D , Bui Division Public Works cq✓� E . DETERMINATIQN OF COMPLETENESS: Complete Comments: Fire Prevention Structural (Tues., Thurs.) Incomplete ❑ � Ip govt 21 Planki Division �J ❑ Permit Coordinator ❑ DUE DATE: 02 -14-06 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ Pw ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: I;(,/ Departments issued corrections: Bldg% Fire ❑ Documents/routing slip.doc 2-28-02 Approved with Conditions j No further Review Required DATE: DUE DATE: 03 -14 -06 Not Approved (attach comments) DATE: Ping ❑ PW ❑ Staff Initials: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the marl, fax; etc Date: 3-10 -0 (p Plan Check/Permit Number: D06 -04-3 ® Response to Incomplete Letter # 1 to Correction Letter # 1 ❑ Response to Correction Letter # ❑ Revision # _ after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner .a■ IL s . \applicadensVormsappliabons on linekevision submittal Created: 8-13 -2004 Revised: Steven M. Mullet, Mayor Steve Lancaster, Director RECEIVE CITtTlilNhu MAR 1 0 Y006 PERMIT CFA Project Name: STEPPING STONE VENTURES Project Address: 14005 42 Av S. Unit 4'- Contact Person: Erin O'Leary Phone Number: Summary of Revision: n Pee. 4<cn y . "A1 d 0)12. Qn nt, i ►vac -Fn rt svLpv }- [a.) c1r(5 hu+ 1 (Usk..? 0&41- ,trh4Q 444 ■4 -1\,d ' � t,-c) gr. Y)W rp vleW ;ACluarea c ao.. -ear 4& 41Wv,4 . '; 11-- Pcir rnk4:6Vi 0 V) /Spa mot, 4 , kerrn .c>, `Per IJor ^. e3r9loco '4 twas otytee4 41. f S-P-f Sitioet rk ors a ce.(4 6-14, , 4, no meal 41) a it -hoh dor raw; z 6 Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: i614 /at 5/1_ Entered in Permits Plus on -/' 10-"0(p Date: cal — 01 oa' 0 (r7 City of Tukwila Project Name: Stepping Stone Ventures Project Address: 14005 42 Ay S, Unit 42 Contact Person: Erin O'Leary Summary of Revision: i _ rn / U Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us pp ictos ors -apm mlessubmittal Created: 8 -13 -2004 Revised: Plan Check/Permit Number: D06 -043 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Steven M. Mullet, Mayor Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Phone Number: C -484 3 IWO Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: i Entered in Permits Plus on ' '222''0( Quvner information : ,. , .... Name: ``c ,, Name: • drefl.:OnAtFl (� 1'* av , Address i3n.�.R n' (\V.c_ on t q q4 .3A4 © Phone: a (o 4wi r-csw4h CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 RECEIVED CITY OF TUKWILA FEB 1 O 7OnF PERMIT CENTEM rpattA Tb:be conipietedtkappiicant ` Site ackiress (attach ma of emotion showing hydrant location and size of mein): 14015 y ik- S Ivkbtic10 Lf7A e, 1ot�3 � This certificate Is for the purposes of. ❑ Residential Building Permit ❑ Preliminary Plat ❑ Commercial/Industrial Building Permit ❑ Rezone Estimated number of service connections and water meter size(s): Vehicular distance from nearest hydrant to the closest point of structure is n. Area is served by (Water Utility District): GO Pt-FS– 4\ i S + ' as � a rm / Owner /Agent Signature j( I Part S -To .be completed by;watei utility district 1. The proposed project is within 2. f,nf6 improvements required. 3. The Improvements required to upgrade the water system to bring it into compliance with the utilities' comprehensive plan or to meet the minimum flow requirements of the project before connection and to meet the State cross connection control requirements: (Use separate sheet If more room is needed) \applications \water availability (7 -2003) Printed: 9 -16-03 CERTIFICATE OF WATER AVAILABILITY Required only If outside City of Tukwila water district tE 5. Water availability: . cceptable service can be provided to this project O Acceptable service cannot be provided to this project unless the improvements in Item B-2 are met. O System is not capable of providing service to this project. I hereby certify that the above information is true and correct. Date Permit Center /Building Division: 206-431-3670 Public Works Department: 206 - 433 Planning Division: 206431 -3670 PERMIT NO.: Pa Q-ou7 ❑ Short • d t -9/ Other Gweuc j .4k �e .ON:4' —/ 9 (City /County) 3 od 0 4. Based upon the improvements listed above, water can be p ded and will be available at the site with a flow of at 20 psi residual fora duration of 2 hours at a velocity of fps as documented by the attached calculations. gpm (0. 0 ZS c A A -L. Z,)—a6 Agency/Phone By Date 1 - --d7 License Information License ESECOI.000RA Licensee Name ESE CONSTRUCTION INC Licensee Type CONSTRUCTION CONTRACTOR UBI 602034081 Ind. Ins. Account Id #2 Business Type CORPORATION Address 1 7189 F &S GRADE RD Address 2 City SEDRO WOOLLEY County SKAGIT State WA Zip 98284 Phone $6,000.00 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/1/2000 Expiration Date 12/1/2007 Suspend Date Separation Date Parent Company Previous License ESECO••011 RA Next License Associated License Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date #2 CBIC SC6302 12/01/2001 Until Cancelled $12,000.00 11/30/2001 #1 CBIC SC6302 12/01/2000 12/01/2001 $6,000.00 11/20/2000 Business Owner Information Name Role Effective Date Expiration Date SOINIE, RONALD E 01/01/1980 SOINIE, ROLENE K 01/01/1980 Look Up a Contractor, Electrician or Plumber License Detail Page 1 of 2 Washington State Department of Labor and Industries General/Specialty Contractor A business registered as a construction contractor with L&I to perfonn construction work within the scope of its specialty. A General or Specialty construction Contractor must mamtain a surety bond or assignment of account and carry general liability insurance. https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= ESECOI *000RA 03/15/2006 v- lov�lr. � A PORTION OF THE S.E. 1/4, S.W. 1/41 SEC. 10+5, T.W.P. 23 N., R. 4 E., W.M., IN KING COUNTY, WASHINGTON i!.!"e COPY 140TH 6T. — EDGE OF PAVERENT – – -- _ •_�_ _ _ ye2� EDGE OF PAVEMENT ^ � -- 1 tfi�' 2.11°0 1 N07.51'23•V- – — al- i – •---a- – – 531.14' NODULAR Ip O 1 % Ilk �,Ly yy % NTBMB Mt HNNE iD N70ULAR HoE i 30' 'p MODULAR NOW Y I a3.� 11 I({X4'1 MODULAR MOE A I•� O I� ❑`'I 41 ��Ily /f -w NODpLAR 10C 71 13G LiG7 RQ ❑ C ' V 14x52 �-' to 1 r. � i/ �� �(±1 IOBLAR NOME r S /Y• f I t / TONING Co. 1 p ' A EX 111111G. I UTILITY B DFi 4 13.n 7 P C Nr C I N VA .. Tkkb H� I (/ I 59� � NDpU.AR HOME r I EDGE CIF PAVEMENT I 4, •• I I EDGE OF PAVEMENT' l (Tlj) ),' i 11) 38 q rlx Ile �� li° T13) 42.11, )ta' .!5!• , MV T1.75 -IL75 1:1 I MT fy Ian t , �( (sl 14ts 12 G N NB •5 t 4A 50720; _ ((UU _ _ _ _ _ (• � 6. 141 ST. Sr. -- _— _ -- -- c _ Cd Five.ofi ' ilj'III�III�II 'III :I�I�I�III�III�IIII'I Inch 1118' Sincc $TCOTT" �III�IIIIIIIII�IIIIIIIII�IIIII .IIIIN�llllllll•I�Lil01lll7l L. l�ll111-ITI- 11sll��1��`��1�� Rtw. 1• LIlJJJ�lll�lllllllli1111111111�111111111�111111111�111111111�111111IIl�Nlllllll�IIIIIIIII�IILII i CODE WED FOR B OMPLIANCE , MAR 7 5 2006 wAa —N— • ;Ii ITI 1'11•t1ll- < I! jI (r' 1!`iitl Slr r «( BASIS OF WAAINO N87T33'07r" 'S S)OVN 01 105 TW. 23 SURVEY AS RE- CORDED IN VOLUME 97, PAGE 153, RCORDS OF KING COUNTY, WASHINGTON. INSTRUMENT USED • A FIELD TRAVERSE USING A SOKKIA 3100 TOTAL STATION :INSTRUMENT WAS USED TO ESTABLISH THE ELATIONSHO BETWEEN THE CONTROLLING MONUIENTATIUN AS SHOWN. LINEAR AND ANGULAR CLOSURE OF TRAVERSE MEETS THE STANDARDS OF VAC 332 - 130 - 090. LEGEND �b0./ A FOUND MONRENT AS NOTED ® RECO DTD IN VTOL•A ENpp C DG „ , DES; D,� CORRECTION DURING NEW CONSTRUCTION OF INTERNATIONAL BLVD. (PACIFIC HWY. SOUTH) T R # O SET No. 5 RCBAR MID I.D. CAP L TITL P�DRT ORDER NM 1145210 PREPARED BY CHICAGO TITLE INSURANCE COPANY. 2, THE FOLLOWING RECORD DF SURVEYS VOL. 97 PG. ISS L 136. -Mu MwvLT BT "TECH DATED OCH'1999 ANO PLAT of JAMES CLARK'S GARDEN RECEIVED ADDITION TO TFE CITY 1F SEATTLE v1IL t3 v PLATS, PG. 12. AND CITY OF TUKWILA THE PLAT Cf BOBBINS VIEW TRACTpp'ADD., VOL. 17. PG. 90. 3' (PACIFIC HIHWY I S-) AS PERYVA�RRANIY DEE S IASEPER RECORDING No.'S r�• 20020"6003153 AND 20020.16003156 CONTAIN HUFEROUS ERRORS AND CAN�EB 2 3 2006 NOT BE ESTABLISHED. RIGHT DF VAY DRAWINGS REFERED TO 1N LEGAL DESCRIPTION W NOT EXIST < ACCORDING TO THE CITY Or TUKWILLA ENGINEERING DEPARTMENT, HPROVEMENT DRAWINGS ONLY) 4, MONUMENTS IN INTERNATIONAL BLVD. ,(PACIFIC HIGHWAY SOUTH) HAVE BE -1- EN DESTROYED DURING NEW CbNSTRUCTIOL CENTERLINE ESTABLISHED ERMIT CENTEh FROM SURVEY BY V, NINE SURVEY DATED ALIGIST 197R. L•EQAL DE90RIPTION THAT OF SEATTLE, ACCORDING 'TO BLOCK THE PLATY THEREEOF RECORDED N ADDITION OLUME THE CITY OF PLATS, PAGE(S) 12, IN KING COUNTY, WASHINGTON. LYING EAST or THE EASTERLY MARGIN OF STATE ROAD No.1 (PACIFIC HIGHWAY SOUTID AS ESTABLISHED BY DEED RECORDED UNDER RECORDING NUMBER 20142331 EXCEPT THAT PORTION THEREOF CONDEMNED FOR PUBLIC ROAD AND HIGHWAY PURPOSES IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 6099401 TOGETHER VITH THE NORTH 322.7 FEET Or THE VEST 320 FEET OF THE EAST 540 FEET OF THE SOUTHEAST QUARTER OF THE SOUTHWEST QUARTER OF SECTION 15, TOWNSHIP 23 MONTH, RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, VASNINGTO. EXCEPT THAT PORTION THEREOF CONVEYED TO THE STATE O' WASHINGTON FOR STATE ROAD No. 1 (PACIFIC HIGHWAY SOUTH) BY DEED RECORDED UNDER RECORDING NUMBER 20481441 AND EXCEPT THAT PORTION THEREOF CQ(DEMMNED FOR COUNTY RIGHT O• WAY (42ND AVENUE I SOUTH) IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 6140901 ' TOGETHER WITH THAT PORTION Or VACATED 40TH AVENUE SOUTH (CONNECTION STREET) LYING EASTERLY OF STATE ROAD N0. I (PACIFIC HIGHWAY SOUTH) AND ADJOINING ALL THE HEREIN ABOVE DESCRIBED PARCEL OF LAND) EXCEPT THOSE PORYIONS CONVEYED; TO THE CITY IF TU(VILLA BY DEEDS RECORDED UNDER RECORDING NUMBERS 20020416003155: AND 20020416003156. (LEGAL DESCRIPTION FROM CHICAGO ;TITLE INSURANCE ORDER No. 1145210 sow ` 'rw C/o JERRY HMBOTIIE ROSH- WJMTTU CNIERM REAL ESTATE 1715 114TH. NNE. Si. SUITE 112 ,4 i A PORTION OF THE SE 1/4, S.W. 1/4, SEC. 15, T.W.P. 23 K. It 4 E.. W.Y., N KNO COUMrY, WASHMON VAN CLISAVS AND ASSMATO 112 CANDLMTK.DRIVE WEST LAKEWOOD, WASHINGTON 98499 (2331 !SI(n -1!191 MAR 15 2006 `,. Qf Tk�vil� 1TR1r, TY1 f (gr(IN siding products and accessories in the world. ..h ganels;� unpact As a leading manufacturer of vinyl product; isure s look their best. Variform has continuously engineered, and ?tea ~ innovated to`produce and offer the highest quality . checked for compound product with the latest technology available. y and heat distortion. All Variform products are made in the U.S.A.; built to stand the test of time. and are backed In p Jill lllll I l 1111111I1111111 11 l��Y��ll111I1 1 T44 S 16 l 6 Inch 1/16 I yl. D. / Slnc� a 8711 t f a - i 5 Ig ?I� , g Ig -' y I6 IZ I IL Wol n nilnn IIII�IIII IIII�IIIJ..Llll1illl I IIII11III nliH] W HIlin ll IIII IIII 1111 III I Illl1llll 1111111111111111111 IIIIiHII 111111111 IIll1lll.1 Ria'al ProGuard' INCOMPLETE LTR #_I_ CORRECTION RECEIVED CIlYOFTUKMLA LTR #—.Y._!_._.r _- MAR 10 2006 PERMIT CENTEH o(j-#- S ProGuard VINYL SKIRTING rig, I - � 11 at, MATERIALS C A L C U L A T I O N S I " AS -BUILT " A PORTION OF THE S.E. 1/4, S.W. 1/4, SEC. 15, T.W.P. 23 N., F1. 4 E., W.M., IN KING COUNTY, WASHINGTON REVIEWED CODE COMPLIANCE — --- — 6(1T1 MTn►r_ wila EDGE O' PAVEMENT — — 2K� EDGE UR PAVEMENT in 531.14' ��,►¢ 2y\ a0 MODULAR ")PC )1 I t 50' /yy'/y % MOa1LAR MODULAR HOME ta) 30' t �y �° ►�` 88 I'fx9�l MOER LAR NONE ,10 MODULAR NONE 1� 14 %4�! MOA,LAR 'ONE �� � -> (J K ° 136 13 C1 IT.q 1s —CJ --I •b4 Ny l!.4W MODIA.AR N10HE — C.l�l IY2 NO \ . d' � �: •'�'� ��1 MODULAR )OE , �S y� fs, � 1 p TOWING C. . ND 4tV ( r 0*11 y /��hti _ � UTILITY ILDG � I �-� � ,mot• U \V/ Iq I� � � � a I V vesr j0• A0* \ham I ( I ^ I� INXrJ(o ' �4 \0 _� '� �` w Ys �- 6 l II o MODULAR NOW EDGE O PAVEMENT I ' EDGE OF PAVEMENT t 12. I n:s 3> -IL75 q 7;1 P Yy% LJ Me •512 Vvt °a a 20 SEPARATE PERMIT REQUIRED FOR: le Mechanical I� Electrical (� Plumbing [� Gas Pip*,ng City Of TldiCt%tiltu BUILDING DBaSION S. 141 ST. ST. _ — - - - - - N N ��`I�IONS il:D ch on9w 51mill be made to 07 wwk Tupzmilla Bt:sMiG4t� NOTE- Revisions will require a revs and may Include additional plan rcv;1_._::..: 1 2 ` Inch t /is Vl i® nlJinllinllliillillllinluu�Lillllulli ii��ll�il�`IIIIIJlJ �1 Aw �. Rf M MvIeW approval Is subject to en'ors and off* Approval of construction documents does not &A violation c: cccepted code or ordinance. R Of ved , F -.,I and rMwItkIns is aclux" B By Da — - -N- � of TUkwb BASIS OF BEARING SOUTH LINE OF S.V. 1/4, SEC. 15, T.W.P. 23 K, R. 4 E., N07 .35'07•V, AS SHOWN ON RECORD OF SURVEY AS RE- CORDED IN VOLUME 97, PAGE 155, RCORDS OF KING COUNTY, WASHINGTON. INSTRUMENT USED A FIELD TRAVERSE USING A SOKKIA 3100 TOTAL STAT113N INSTRUMENT WAS USED TO ESTABLISH THE RELATIONSHIP BETWEEN THE CONTROLLING MONUMENTATION AS SHOWN LINEAR AND ANGULAR CLOSURE OF TRAVERSE MEETS THE STANDARDS OF VAC 332 - 130 - 090. LEGEND �100411 9 FOUND MONUMENT AS NOTED ® CALCULATED MONUMENT RECORD OF SURVEY AS RECORDED IN VOL. 18, PG, 29. MONUMENT DESTROYED DURING NEW CONSTRUCTION OF INTERNATIONAL BLVD. (PACIFIC HWY. SOUTH) O SET No. 5 REBAR AND I.D. CAP REFERENCES 1. TITLE REPORT ORDER No. 1145210 PREPARED BY CHICAGO TITLE INSURANCE COMPANY. 2. THE FD.LOVING RECORD OF SURVEYS VOL. 97 PG. 155 t 156, VOL. 16, P4 29, VOL. 44, PG 200, UNREC13RDED SURVEY BY EIRTHTECH DATED MARCH 1999 AND PLAT OF ,JAMES CLARK'S GARDEN ADDITION TO THE CITY OF SEATTLE. VOL. 13 UR PLATS, PG. 12, AND THE PLAT IMF ROBBINS VIEW TRACT ADD.. VOL. 17, PG. 90. 3. ADDITIONAL RIGHT OF WAY AOIUIRI*9 ALnr. 11NTrDNAYI(NA1 N Vn CITY OF TIUKWILA FE8 l n ?nna PERMIT C 51 I I I 61 lil�lilllllilllllllilil�llll�llll�lill�llll�llll�llll�llll�llll�flll�llll�ihl�llll�llll� ' CAN 4. BY V. MINE SURVEY DATED AUGUST 1978. LZOAL ONSORIPTION THAT PORTION Q LOT B, BLOCK 1, ,MITES CLARK'S GARDEN ADDITION TO THE CITY I3F SEATTLE, ACCORDING TO THE PLAT THEREOF, RECORDED IN VOLUME 13 OF PLATS, PAGE(S) 12, IN KING COUNTY, WASHINGTON. LYING EAST UR THE EASTERLY MARGIN OF STATE ROAD No. 1 (PACIFIC HIGHWAY SOUTH) AS ESTABLISHED BY DEED RECORDED UNDER RECORDING NUMBER 20142331 EXCEPT THAT PORTION THEREOF CONDEMNED FOR PUBLIC ROAD AND HIGHWAY PURPOSES IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 6099481 TOGETHER VITH THE NORTH 322.7 FEET OF THE VEST 520 FEET OF THE EAST 540 FEET OF THE SOUTHEAST QUARTER OF THE SOUTHWEST QUARTER O' SECTION 15, TOWNSHIP 23 NORTH. RANGE 4 EAST, WILLAMETTE MERIDIAN, IN KING COUNTY, WASHINGTON EXCEPT THAT PORTION THEREOF CONVEYED TO THE STATE OF WASHINGTON FOR STATE ROAD No.I (PACIFIC HIGHWAY SOUTH) BY DEED RECORDED UNDER RECORDING NUMBER 2048144/ AND ' EXCEPT THAT PORTION THEREOF COtDENED FOR COUNTY RIGHT UR WAY (42ND AVENUE SOUTH) IN KING COUNTY SUPERIOR COURT CAUSE NUMBER 6140981 TOGETHER WITH THAT PORTION OF VACATED 40TH AVENUE SOUTH (CONNECTION STREET) LYING EASTERLY OF STATE ROAD 140. I (PACIFIC HIGHWAY SOUTH) AND ADJOINING ALL THE HEREIN ABOVE DESCRIBED PARCEL OF LAND1 EXCEPT THOSE PORTIONS COlVEYED'TO THE CITY OF TU(WILLA BY DEEDS RECORDED UNDER RECORDING NUMBERS 20020416003155: AND 20020416003156. (LEGAL DESCRIPTION FROM CHICAGO TITLE INSURANCE ORDER No. 1145210) ` TDB C/0 JERRY II( OMU ROSEN -WMTRE COHFRCHK REAL ESTATE 1715 1147K TAE. S.E. SUITE 212 A PORTION O THE S.E. 1/4, S.W. 1/4. SEC. 15, T.W.P. 23 K, K 4 E. WJL, IN KING COLNTY. IMSH NGTON x VAN MWE AND ASSMATO 112 CANDLEWYCK DRIVE WEST LAKEWCIOD. WASHINGTON 98490 (253) 588 -3821 BVM BY, K.V.V. Jr. 100 BT��. AP M iri K.1 ,ATE 07 /OS MR 07 I)S ,AR 07 OS P.B NO LL /EFB BVG No, 05- 1180AB