Loading...
HomeMy WebLinkAboutPermit EL08-0987 - WESTFIELD SOUTHCENTER MALL - THAI GO NOODLE ZONE - STORAGEThis record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL08 -0987 Thai Go Noodle Zone — Storage 2600 Southcenter Mall RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 11 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. THAI GO NOODLE ZONE STORAGE 2600 SOUTHCENTER MALL ELO8-987 CitAgf Tukwila s Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -0987 Issue Date: 08/27/2008 Permit Expires On: 02/23/2009 Tenant: Name: THAI GO NOODLE ZONE STORAGE Address: 2600 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: ELIZABETH MONTGOMERY Phone: 206 322 -4323 Address: 1405 BOYLSTON AV , SEATTLE WA Contractor: Name: BEST ELECTRIC CORP Address: 14027 69 AV SE , SNOHOMISH WA Contractor License No: BESTEC *070M7 Phone: 206 679 -7617 Expiration Date: 08/04/2009 DESCRIPTION OF WORK: LIGHTING AND ELECTRIC PANEL Value of Electrical: $10,000.00 Fees Collected: $307.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Date: 0$l L'c ed this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: _'`121 Date: CI 6 e Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -0987 Printed: 08 -27 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW THAI GO NOODLE ZONE STORAGE Permit Number: Status: Applied Date: Issue Date: EL08 -0987 ISSUED 07/15/2008 08/27/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 47-2- 7-0 doc: Cond -Elec kc--e EL08 -0987 Printed: 08 -27 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http //www. ci. tkwila. wa. us Electrical Permit No. f , D 1.1— CObl Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: // � Tenant Name: l ��` t tU0 UZ k 2-o)-1-(2— Property Owners Name: [Pe- 51 King Co Assessor's Tax No.: Suite Number: 9 2 305 G 623E-9lodr: New Tenant: ❑ Yes ❑..No Mailing Address: City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: 1416 1} i) ' E -Mail Address: Day Telephone: �� City " State Zip ($t/ CiA/11 j1,N �• /) 1 t/OvI Fax Number: �ojj ° 322 ` q / 7 ELECTRICAL CONTRACTOR INFORMATION Company Name: �- S� EL -06 T1Z16 Mailing Address: 12 71 ci N 1b3rO (t o°AAVi Ile City p Day Telephone: 2 G e 4 ��2J ?(� E -Mail Address: , I ' - Fax Number: W Contractor Registration Number: e 5+ c F O ► r 02 / Pc Expiration Date: Contact Person: koNI Cat Iv) Stat Zi Valuation of Project (contractor's bid price): $ /0/ of U 0 Scope of Work (please provide detailed information): ( �.r(( 'u tt ,�Q t� '{ j b%'L. Will service be altered? [g Yes ❑ No Adding more than 50 amps? Type of Use: Type of work: t1 New ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Property Served by: NI Puget Sound Energy ❑ Seattle City Light H:1Applicaaons\Fonns- Applications On Ltne14 -2007 - Electrical Permit Application.doc bh Yes ❑ No ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair ... . $65.00 ❑ Low voltage systems .$55 00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: l �` Print Name: Mailing Address: IDate Application Accepted: z ),PJZ-\ /61- .- 3Gv-ev L S -P.c Date: 71/3/ d Day Telephone: 2G6 3 2-2 - %_S',71- j t-J City State in'll <l,7t Date Application Expires: Staff Initials: H \Applicanons\Fonnc- Applications On tine\4.2007 - Electrical Permit Application.doc bh Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -0987 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/15/2008 Applicant: THAI GO NOODLE ZONE STORAGE Issue Date: Receipt No.: R08 -03063 Payment Amount: $360.00 Initials: JEM Payment Date: 08/27/2008 08:45 AM User ID: 1165 Balance: $0.00 Payee: WEST COAST PROPERTY MAINTENANCE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3090 360.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000/345.830 360.00 Total: $360.00 -.:' doc: Receiot -06 Printed: 08-27 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit frog- 09Y1 PERMIT NO. (206)431 -3 70 Project: T I(AO �� ,E Type of Inspection: ^ 1 , OD N,„ . Address: ZGvoo tied/. Date Called: Special Instructions: Date Wanted: 9 / i7 # Cia3 m. Requester: Phone No: 0 ElIX I Approved per applicable codes. Corrections required prior to approval. COMMENTS: . L. / r‘Att'l� Inspector: 13(7,(4a\ Date: 1/11 1 �� L1$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: � PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -0987 DATE: 07 -15 -08 PROJECT NAME: THAI GO NOODLE ZONE STORAGE SITE ADDRESS: 2600 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DE ARTMENTS: BuiPing vision Public Works ❑ Fire Prevention Structural Planning Division n nPermit Coordinator ❑ DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07-1 7-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUT NG: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: C APPROVALS OR CORRECTIONS: DUE DATE: 08-14-08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. //www ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -02583 Initials: JEM Payment Date: 07/15/2008 User ID: 1165 Payee: THAIGO NOODLE ZONE Total Payment: 518.50 SET ID: S000001079 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount 4 E,gogm04 8 7 307.50 PGO8 -206 211.00 TOTAL: 518.50 TRANSACTION LIST: Type Method Description Amount Payment Check 1028 518.50 TOTAL: 518.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES PLUMBING - NONRES 000.322.101.00.0 246.00 000.345.832.00.0 61.50 000/345.830 35.00 000.322.103.00.0 176.00 TOTAL: 518.50 4E159 07/15 0711 TOTAL 518.50 Doc: RECSEIS -06 Untitled Page a Page 1 of 1 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company BEST ELECTRIC CORP 2066797617 14027 69TH AVE SE SNOHOMISH WA 98290 SNOHOMISH CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601480887 ACTIVE BESTEC *070M7 ELECTRICAL CONTRACTOR 7/27/1993 8/4/2009 LEE * *S *973 DS GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License LEE * *S *973DS Name LEE, SAM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date LEE, SAM 01/01/1980 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 07/27/1993 Until Released Bond $4,000.00 https: // fortress .wa.gov /lni/bbip /Detail.aspx ?License= BESTEC *070M7 08/27/2008 9' -1 O" DISH WASHER 7 12'-x" SHELVING STORAGE SHELVING ELECTRICAL PANEL(EP) 6 Ci; iltK rze tea.% r;!$a 2:2 ;;K:t3 =. . 52,1% fill K ! a 1g a I Ii 2I z <a47 ELECTRICAL POWER PLAN SCALE 3/8° = 1' -0° PANEL SCHEDULE "EP" VOLTAGE 0120/208V., 3 PHASE, 4WIRE. 277/480V., 3 PHASE, 4WIRE LJ 208V., 3 PHASE, 3 WIRE 480V., 3PHASE, 3 WIRE MOUNTING: FLUSH FISURFACE MAIN: LUGS ONLY AMP. [MAIN BREAKER 200 AMP. PLUMBING TOP BOTTOM NEUTRAL n 50% 2100% COVER: n DOOR WITH LOCK DOOR WITHOUT LOCK ALL BREAKERS AMP. POLE UNLESS NOTED OTHERWISE U/L LISTED BREAKER INTERRUPTING CAPACITY : RMS SYM. AMPS. CONNECTED LOAD: PHASE A W., PHASE B: W., PHASE C., W., TOTAL WATTS LOCATION LOAD NO. AMERICAN FLUORESCENT ABC 2 PIN FLUORESCENT *— NO. LOAD LOCATION 2 256 LIGHT (F1) L M RECEPTACLE @WORK TABLEO 250 1 E1 111 1 BEST LIGHTING M M RECEPTACLE @WORK TABLE Q RECEPTACLE @WORK TABLE 14 250 250 3 5 4 400 WALK -IN COOLER LITS +BLOWER M H MOP SINK 24 "X24 "X10" 6 100 ,_ WALK -IN COOLER a K M RECEPTACLE @WORK TABLED 250 7 8 100 ,) WALK -IN COOLER K I MOUNTED SHELVING ADVANCE TABCO K FREEZER 80 1500 9 10 1000 WASHER ® K �� 30 4 12 3000 WATER HEATER M WING TABLE CUSTOM 11 11 13 14 3000 (RHEEM E5.50.9.G) M I 1 DISH WASHER MACHINE AUTO -CHLOR 1000 10 1/2 120 1 15 16 3000 (RHEEM E5.50.9.G) M 30 "X33 "X72' 6 ® 2 STORAGE SHELVING 17 18 1I 20 16 "X60 "X6' 7 ►.► 19 1 I CUSTOM 9.1 208 21 22 I 8 24 1 FREEZER 54.125 "X19.5 "X78.375" TRUE (T -49F) 23 115/60/1 3/ 1/2" 1/2" 2 1 -jJ2" 1-1/2 25 26 NEMA 5 -20R DIRECT DRAIN INDIRECT DRAIN 9 1141 I 1 STORAGE SHELVING 64 "X21 n 28 10 ® 1 27 11 II 1 WALL MOUNT HAND SINK /W FAUCET 12 29 30 1 2 COMPARTMENT SINK ADVANCE 9- 2- 36 -24L *FIELD VERIFIED BY INSTALLER LOAD SUMMARY MIS LIGHTING KITCHEN TOTAL LOAD AMTEXES CONNECTED LOAD CODE FACTOR COMPUTER LOAD 10,400 100% 10,400 256 125% 320 3,900 65% 2,535 14,556 40 13,255 37 REFERENCES TO 2005 NATIONAL ELECTRICAL CODE LIGHTING FIXTURE SCHEDULE SYMBOL SYM NO. NO. FIXTURE QTY. QTY. MANUFACTURE MODEL NO. WATTS LAMP \UMBER ELECTRICAL PLUMBING GAS NOTES : : C!) o_ > < 0_ = F1 FLUORESCENT FIXTURE 4 AMERICAN FLUORESCENT 32X2 2 PIN FLUORESCENT *— 7 1 SINGLE POLE SWITCH 2 1 WORK TABLE • E1 EMERGENCY LIGHTING 1 BEST LIGHTING 1 BATTERY BACKUP © 13,14,16 LQ J P \T L ST REFLECTED CEILING PLAN SCALE 1/4 = 1'--0° SPECIAL NOTES 1. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION OR CORE DRILL AND OR POSITIONING OF ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD - APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 2. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER (MINIMUM SIZE 2A: 208C), WHEREVER ANY WELDING IS DONE WITH THE DEMISED PREMISED. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST ON (1) HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. ELECTRICAL SYMBOLS EP TIP r._ ELECTRICAL PANEL, 200A, 3PHASE 120/208V.4W. 3OCKTS RECEPTACLE 208V. 3PHASE, 3 POLE, 30A SWITCH DUPLEX RECEPTACLE, 120 —VOLT, 1 PHASE JUNCTION BOX AS REQ'D II DENOTES 2 #12- 3 /4 "C(ONE NEUTRAL) (THHN,CU) NOTES: 1. JUNCTION BOX SHALL BE INCLUDED WHEREVER NEEDED. ALL WIRE SHALL BE #12 (THHN,CU) OTHERWISE NOTED & SHALL BE MET CODES REQUIPMENT 2. PROVIDE INSULATION GROUND WIRE FOR ALL EQUIPMENTS PER NEC - 250 -95. 3. INTERLOCKING SYSTEM SHALL BE PROVIDE FOR CUT OFF GAS VALVE, MAKE-UP AIR FAN & LEAVE EXHAUST FAN ON. 4. ALL LIGHTING SYSTEM SHALL BE MET LOCAL CODES AND STATE CODES. 5. CONTRACTOR SHALL FINISH WIRED FOR ALL EQUIPMENT INCLUDING RECEPTACLES, & LITS INSIDE THE HOOD. 6. CONTRACTOR TO VERIFY THE ACTUAL LOADING OF EQUIPMENT AND SIZE BEFORE INSTALLATION. 7. WIRE COLORS- PHASE A- BLACK, PHASE B -RED PHASE C- BLUE, NEUTRAL- WHITE SEPARATE PERMIT REQUIRED FOR: Mechanical Q,Electrical Plumbing C�J Gas Piping City of Tukwila 13 MLDING DIVISION Permit No .-.' I,EWED FORE CC ®E C� �� NEC JUL 22 l et City Of Tu 1 BUILD N .D @PIVIEria D E S I G N S T U D I O PLANNING AND INTERIOR DESK 1405 BOYLSTON AVE SEATTLE, WA 98122 TEL 206222.4323 E- MALWO•CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM EN .JOHN BLACKLAW/THOMAS U 1602212TH AVE SW. BUFEN WA 98166 PROJECT TITLE r� AND ?PI oqi If/ Plar review approval 13 subject to errors and Orntsions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and corn:Wong is aawledged By Date:, 2 v City of Tukwila BUILDING D REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional Ian review fees. CITY OE TUKWILA JUL ,15 2008 PERMIT CENTER STORACE AND PREP. ROOM WESTFELD MALL (11JICWLA, WA) SHEET TITLE: FLOOR PLAN, CBLf4G PLAN EOUPMST UST, DETAILS REVISIONS NTEI:OR DESIGN CATCH DESIGN STUDIO DRAWN TOMAS LI CHECKED: DATE 7/10/08 SCALE AS NOTED FILE: SKEET# E1 SUPPLIER DESCRIPTION hCUSTOM vANUFACTURER vOD -L \UMBER ELECTRICAL PLUMBING GAS NOTES : : C!) o_ > < 0_ = Z -. O U 1---- O = O� O U i O U = 1- CO O C!? CD 1 III- -41 1 WORK TABLE 2 ►- 1 MOP SINK 24 "X24 "X10" ZUM INDUSTRIES 3 ■■ 4 MOUNTED SHELVING ADVANCE TABCO 4 ® 1 WING TABLE CUSTOM 5 ►-4 1 DISH WASHER MACHINE AUTO -CHLOR 1000 10 1/2 120 1 1/2' 30 "X33 "X72' 6 ® 2 STORAGE SHELVING ADVANCE TABOO 16 "X60 "X6' 7 ►.► 1 WALK -IN COOLER 6'X10 CUSTOM 9.1 208 1 NEMA 5 -15R 8 ' 4 1 FREEZER 54.125 "X19.5 "X78.375" TRUE (T -49F) 13.2 115/60/1 3/ 1/2" 1/2" 2 1 -jJ2" 1-1/2 NEMA 5 -20R DIRECT DRAIN INDIRECT DRAIN 9 1141 1 STORAGE SHELVING 64 "X21 n ADVANCE TABCO ADVANCE TABCO ADVANCE DI -1 -10 10 ® 1 STORAGE SHELVING (72 "X21 ") 11 ►V 1 WALL MOUNT HAND SINK /W FAUCET 12 110"411 1 2 COMPARTMENT SINK ADVANCE 9- 2- 36 -24L 13 ■111 1 HOT WATER HEATHER (ELECTRIC) 50 GALLONS RHEEMP ES5O -9 -G 9 25 208 3 14 11.--44 1 WORK TABLE CUSTOM 15 ® 1 STORAGE SHELVING (30 "X24 ") ADVANCE TABCO 16 ■( 1 PRE -RINSE AUTO -CHLOR SPECIAL NOTES 1. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION OR CORE DRILL AND OR POSITIONING OF ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD - APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 2. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER (MINIMUM SIZE 2A: 208C), WHEREVER ANY WELDING IS DONE WITH THE DEMISED PREMISED. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST ON (1) HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. ELECTRICAL SYMBOLS EP TIP r._ ELECTRICAL PANEL, 200A, 3PHASE 120/208V.4W. 3OCKTS RECEPTACLE 208V. 3PHASE, 3 POLE, 30A SWITCH DUPLEX RECEPTACLE, 120 —VOLT, 1 PHASE JUNCTION BOX AS REQ'D II DENOTES 2 #12- 3 /4 "C(ONE NEUTRAL) (THHN,CU) NOTES: 1. JUNCTION BOX SHALL BE INCLUDED WHEREVER NEEDED. ALL WIRE SHALL BE #12 (THHN,CU) OTHERWISE NOTED & SHALL BE MET CODES REQUIPMENT 2. PROVIDE INSULATION GROUND WIRE FOR ALL EQUIPMENTS PER NEC - 250 -95. 3. INTERLOCKING SYSTEM SHALL BE PROVIDE FOR CUT OFF GAS VALVE, MAKE-UP AIR FAN & LEAVE EXHAUST FAN ON. 4. ALL LIGHTING SYSTEM SHALL BE MET LOCAL CODES AND STATE CODES. 5. CONTRACTOR SHALL FINISH WIRED FOR ALL EQUIPMENT INCLUDING RECEPTACLES, & LITS INSIDE THE HOOD. 6. CONTRACTOR TO VERIFY THE ACTUAL LOADING OF EQUIPMENT AND SIZE BEFORE INSTALLATION. 7. WIRE COLORS- PHASE A- BLACK, PHASE B -RED PHASE C- BLUE, NEUTRAL- WHITE SEPARATE PERMIT REQUIRED FOR: Mechanical Q,Electrical Plumbing C�J Gas Piping City of Tukwila 13 MLDING DIVISION Permit No .-.' I,EWED FORE CC ®E C� �� NEC JUL 22 l et City Of Tu 1 BUILD N .D @PIVIEria D E S I G N S T U D I O PLANNING AND INTERIOR DESK 1405 BOYLSTON AVE SEATTLE, WA 98122 TEL 206222.4323 E- MALWO•CATCHSTUDIO.COM WWW.CATCHSTUDIO.COM EN .JOHN BLACKLAW/THOMAS U 1602212TH AVE SW. BUFEN WA 98166 PROJECT TITLE r� AND ?PI oqi If/ Plar review approval 13 subject to errors and Orntsions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and corn:Wong is aawledged By Date:, 2 v City of Tukwila BUILDING D REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional Ian review fees. CITY OE TUKWILA JUL ,15 2008 PERMIT CENTER STORACE AND PREP. ROOM WESTFELD MALL (11JICWLA, WA) SHEET TITLE: FLOOR PLAN, CBLf4G PLAN EOUPMST UST, DETAILS REVISIONS NTEI:OR DESIGN CATCH DESIGN STUDIO DRAWN TOMAS LI CHECKED: DATE 7/10/08 SCALE AS NOTED FILE: SKEET# E1