HomeMy WebLinkAboutPermit EL08-1015 - WESTFIELD SOUTHCENTER MALL - MARC ECKOMARC ECKO 837 SOUTHCENTER MALL ELO8-1015 Cityllif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 837 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1015 Issue Date: 08/15/2008 Permit Expires On: 02/11/2009 Tenant: Name: MARC ECKO CUT & SEW Address: 837 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEVIN WENDELL Phone: 412 243 -3430 X 236 Address: 100 EAST SWISSVALE AV , PITTSBURG PA Contractor: Name: ABACUS ELECTRIC LLC Phone: 253 - 984 -1611 Address: 9804 SALES RD S STE A -1 , LAKEWOOD WA Contractor License No: ABACUEL967DA Expiration Date: 03/01/2010 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TI: ADDITION OF TENANT LIGHTING PACKAGE, SPEAKERS, DATA & PHONE LINES, AND ALL RELATED WIRING, ELECTRICAL PANELS, ETC. Value of Electrical: $40,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: 2005 $922.50 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and xami governing this work will be complied with Date: Led this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: Print Name: 1 d2 n (lac s S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1015 Printed: 08-15 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 837 SOUTHCENTER MALL TUKW MARC ECHO CUT & SEW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1015 ISSUED 07/18/2008 08/15/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: g//s-70 (8, doc: Cond -Elec EL08 -1015 Printed: 08 -15 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cLtukwfla.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: JO 47H GE1O7L !', Tenant Name: in 4 C- ECI4•O QT - S t, j King Co Assessor's Tax No.: 6 3 6 f2. 0- ii o 1 O Suite Number:? Floor: 1 New Tenant: Yes El .. No 0-0 25 Property Owners Nanie: L' EST Fl L i-O Co R P ©R T10 L Mailing Address: (t 60 I W I ESN I i21i ISOtFilCt/44Z 0 l T." t-.65 City State Zip CONTACT PERSON - Who do we c rmit is ready t he issu Name: K t=,Vl ,J (JO D EUL.-1 L4✓hl 6-Kw ji rltkriq -wear Day Telephone: 4/2-2-43-34-50 x2% Mailing Address: 1 O0 EA5T 3WiSSPitt.E, f p"EU►te 41 TTS H PA- /5Lis• E -Mail Address: KEG -)0Q-C L/{ in 1 G-e-h /38 , rr'N City State Zip Fax Number: "HE -3 7 1 1526 ELECTRICAL CONTRACTOR INFORMATION Company Name: T60 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ d 00 Scope of Work (please provide detailed information): I N T C - 4 .' ( R rtt u j FIT Our o r . A Its E 1A) L- Y norhl6l- 5(opL C IiJ d} i vo SECT 10 4.1 cE 4N E (51-w& /j 61� �►ttr. 1100rioa of TGN4}vT L!CHIN C' At44CC/ SP€AlZ- 2Srl��T/} PNey cl�;cS Awn 4i-t.- e, w1 XI PG - , cTP.ic 1. Phut+ -5 ETA. Will service be altered? ❑ Yes Q No Adding more than 50 amps? ❑ Yes ® No Type of Use: oI✓RCa #J 11 L. Type of work: ❑ New ❑ Addition • Low Voltage ❑ Generator (seem-eft 10,+ -r A, recto od Property Served by: Puget Sound Energy ❑ Seattle City Light ❑ Service Change GE Fire Alarm H.'\Applications■Forms- Applications On Line,4-2007 - Electrical Permit Application.doc bb ❑ Remodel ® Telecommunication Tenant Improvement Temporary Service Page 1 of 2 • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits...,. $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL-- Fees are based on ation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (gene $75.00 ❑ Manufacttued/m e home service 580.00 (excl i g garage or outbuilding) ❑ C vats 575.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrates. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signa Print Name:ka ENDS' -lam ).#n,t (rfitiOB I'Apgc.NAxuf Mailing Address: 160 EAST $t�t►55vALE f�V�tukE IDate Application Accepted: Date: v 7/1¢/0$ Day Telephone: 412-24 3 -343 0 firts8ha4 -il city state Zip Date Application Expires: 01, [ (4 Staff Initials: H:Wpplications\Fomts- Applications On Line4-2OO7 - Electrical Permit Application.dnc hh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -1015 Address: 837 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/18/2008 Applicant: MARL ECKO CUT & SEW Issue Date: Receipt No.: R08 -02961 Initials: JEM User ID: 1165 Payment Amount: $828.29 Payment Date: 08/15/2008 11:17 AM Balance: $0.00 Payee: ABACO CONTRACTORS, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5031 828.29 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 738.00 000.345.832.00.0 90.29 Total: $828.29 rtnr.: Rarp,int -f1R Printari• OR- 15.2fMR INSPECTION RECORD f�, �01� Retain a copy with permit L INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION lz 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Project: , d� �Cw Type of Inspection: 00 Address: '37 '1vv Date Called: /---.., Special Instructions: w Date Wanted: ^ "rj 2� l:J" p.m. Requester: Phone No: Ir J Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Inspector: 111 ibeddcic Date: J 0\3 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: NSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1z- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I (ag - loic Project: c mozr �i l.. Type of Inspection: 7./00 Address: g31 timiti Date Called: ?A-1- Special Instructions: Date Wanted: 9 /17 p.m. Requester: OF 161(60\101 L r4 LTn» Phone No: 0. K. . Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?A-1- OK. - F-1AAt, KAN/ (I 01642-T'1 e Jr A-PfIko J A OF 161(60\101 L r4 LTn» 0. K. . 5rbctc /Smfr. Inspector: .../Tti er\ Date: / //Or El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPE ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. I 1(2- (206)431 -3670 Project: , /¢ L fc ✓ o Type of Inspection: 7D0 2- Address: g31' Date Called: ^ 1 Special Instructions: Date Wanted: cir n 44.m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: . stokila Ni"f C4PerskA6 SO RiStS Inspector: Je;0166x)deic Date: 0111510Y $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 eLo`427_ ►0'S Project: 444(ci �^ ,` Type of Inspection: 7003 Address: v37 volt, Date Called: M't AFL' Special Instructions: Date Wanted: / 0/ a. m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 9 X. - Cf(04(1. COVec M't AFL' • KO'/C04 1 A/ iolifVc Inspector: 6644ec bate: 0170(1/0 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: 0442‘c.„ E04_0 Type of Inspection: 7o0 ; U Address: )39 �AU- Date Called: Special Instructio s: Date Wanted: q i f �� _m Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: vAr 1.46491,10 it(1165 Inspector: (Date: 03/05 /o\g l ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .w. w. yaW 6 _ INSPECTION RECORD f�,g- 01 Retain a copy with permit C INSPECIION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: - R-- Type of Inspection: 1005 0.14 , - Liik. c,ovos, Address: ef.31 Date Called: AIai: feAttt Ac jss (2) pt( l. Special Instructions: Date Wanted: O� { {{ a.m Requester: Phone No: EiApproved per applicable codes. Corrections required prior to approval. ti COMMENTS: R-- 0.14 , - Liik. c,ovos, AIai: feAttt Ac jss (2) pt( 061er ' A-a, ,q--1 CoL /l1M Inspector: &Wei \ Date: Q/ O2 / j g 1 r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 6.0V -101c I PERMIT NO. (2" (206)431 -367 Project: �,I[U Type of Inspection: Tao r Address: V31 Date Called: Special Instructions: i Date Wanted: v Z a.m: Requester: Phone No: I`l Approved per applicable codes. COMMENTS: EJCorrections required prior to approval. • Unlpc(St.u�j ac-4Alti\ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: (RA c oNg 'Date: 1 NSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION its I 601-101c 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Project: _ n too r Type of Inspection: ^D0� Address: 83 ��' Date Called: Special Instructions: Date Wanted: 2.0 1 P.m; Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 74- •' P. 560 Inspector: ir'l! w Ales LI$60.00 REINSPECTION FEE EOUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Date: 0,1 12A)0 Receipt No.: 'Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -02638 Initials: JEM Payment Date: 07/18/2008 User ID: 1165 Payee: LAMI GRUBB MANAGEMENT SERVICES, INC. Total Payment: 1,388.54 SET ID: S000001081 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -379 1,163.83 em8- �1r0,-]! 94.21 M08 -188 101.50 PG08 -209 29.00 TOTAL: 1,388.54 TRANSACTION LIST: Type Method Description Amount Payment Check 0688 ACCOUNT ITEM LIST: Description TOTAL: 1,388.54 1,388.54 Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 94.21 000/345.830 1,294.33 TOTAL: 1,388.54 ,17 D?/t!? 716 TOTE=M.. 1183.51: 2005 Washington Spate Nonresidential Ene !y Code compliance Form 2006 weENnw[on Mule Nonroademlel Energy Code Compliance Forms Project Info Project Address south center t�al1 f k (4 . pate 7/16/2008 d 8 3p/ ► /_C��� ij� 0 tYi'] 001 For Building Department Use FILE COPY _ • 0. r e ,� Ta>nrila, C� Applicant Name: poi nderk Koko cut & see Applicant Address: e> r. Appticant Plane: .. ., Project Description ❑ New Building E Addition El Alteration [] Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). indicate Proscriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Lass than 60% of the fixtures new, installed wattage not Increased, & space use not changed. Maximum Allowed Lighting Wattage Location (door /room no.) Occupancy Description Allowed Watte per ft2 •* Area in ft2 Allowed x Area x Retail 1.50 2540.0 - 3810.0 sic you / Right Combo 1 100.0 100.0 B aowullQbt 4 20.0 80.0 -• From TaDle 1 &-1 (ever) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 3810.0 Location (floor /room no.) • Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed x Traci{ head 109 20.0 2180.0 sic you / Right Combo 1 100.0 100.0 B aowullQbt 4 20.0 80.0 D povenliyht 4 39.0 156.0 a xi.atrip 7 59.0 413.0 nn nomnlieht 6 40.0 240.0 F2 Daanlight 2 32.0 64.0 V CLandelier 1 240.0 240.0 roposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 3473.0 Notes: 1. For proposed Fixture Description, indicate fixture typo, lamp type (e.g. T -8). number of lamps In the fixture. and ballast type (It Includes)). For track lighting, Ilat the length oI the track (in feet) in addition to the fixture, Tamp, and ballast Information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum Input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table In the NREC Technical Reference Mafl al may also be used. For track lighting, /let the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3.1_Ist all fixtures. For exempt lighting, note section and excepticn number, and leave Watts/Fixture blank. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUL 2 9 2008 X77 City Of Tukwila BI DIN .QION RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER fnter._:i 2006 Washington State Nonrestaenttal tnergy l:oae Lonipllance rorm umr)na _ (back 2008 W:aninston sere NonreeIoentlal Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces occupancy O Warehouses, storage areas or aircraft storage hangers ()Other Qualification Checklist Note: If occupancy type Is "Other and fixture answer Is checked. the number at fixtures In the spats Is not limited by Code. Clearly indlcate these wawa on plans if not clea red. do LPA Calculations. Ug in lg Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1 Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps. b) reflector or louvers, c) 5-60 watt T -1, T -2, T•4. T -5, T-8 lamps. and d) hard -wired elec- tronlc dimming ballasts. Screw -In compact fluorescent fixtures do not qualify-. 2. Metal Halide with a) reflector b) ceramic MH lamps r_ 150w c) electronic ballasts 3. LED light. ABLE 15.1 Unit Lighting Power Allowance (LPA' Use' LPA man Use LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas In facilities of other use types (Including but not limited to schools dT hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group I -3 Occupanciee 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments°, restaurants/battis 1.3 1,0 Post office RetairlI retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.1 1.5 D❑rmitoty Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly space? 1.0 Theater, motion picture 12 Health cam dins❑ 1.0 Theater, performing arts Transportation 1.6 1.0 Hospital, nursing homes, and other Group 1 -1 and 1-2 Occupancies 1.2 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall°' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.6 Parking garages 02 Laundriea 1.2 tilebraries5 1.3 Plans Submitted for Common Areas only' Main floor building lobbies' (except mall concourses) 1.2 Manufacturing facility 1.3 Museum 1,1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shell apply. In cases in which a use is riot mentioned epecifically, the Unit Power Allowance shalt be determined by the building official. This determination shall be based upon the most comparable use specked in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty Feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be Increased by two percent per foot of cuing height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be Increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices tess than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ftf may be used, 8) Reserved. 2) For Indoor sport tournament courts with adjacent spectator seating over 6,000, the Unit Lighting Power Allowance for the court area is 2.60 W/fte. 10) Display window Illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1,6 w/ftz of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (riot on the wail). b) adjustable In both the horizontal and vertical axes (vertical axle only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten Halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only If the lighting is actually Installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined In footnote 2 applies only to the floor area not covered by racks. tnerav Loae LOmDIIance 1-0 LI htin 9 9�: 'Motor; }end Tr ansfarilmer PeI mlt Planes Checklist • le 1: - 1. mist Er+all y code Camp large LTG'. CHK. 2000 woeelnetcn - RaWeed July 2007 ProjeatAddresa south a.ntar ersli Date 7/16/200B The following Infontladon Is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements In the 2006 Washington State Nonresidential Energy Code, Applicability Coda (yes, no, n.a.) Section C• •anent Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) h1513.1 yes 1513.2 Local controlacceee Schedule with type. Indtoate locations Si Area controls Maadmum limit per switch El 1513.3 Daylight zone control Schedule with type and features, indicate locations . a . _ vertical glazing Indicate vertical glazing on plane overhead glazing Indicate overhead glazing on plane yea 1613.4 DispleyiexhIbispecial Indicate separate controls Ei 1519.5 Exterior shut -off Schedule with type and features, Indicate location .a. (a)dmerix/backup Indicate location • . a • - (b) photocell. Indloatm location 1513.6 Inter, auto shut-off Indicate location .4 - 1513.6.1 (a) occup. eenaors Schedule with typo and location . a. 1513 82 (b) auto. switches Schedule with type and features (back-up, override capability); indioata size of zone on plans _-IIIIIIII IIIIIIIIII .a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EX T SIGNS (- on 1514) 1614 Max. watts Indicate watts for each alit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532 yea 1531 Interior Lighting Completed tlnd attached. Sohsdule with fixture types, Summary Four tamps, bsliaets, watts per fixture attache , a . 1632 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps. ballasts, watts per fbxkire MOTORS Section 1511 Yea 1511 Elea motor effielenoy MECFI•MOT or Equipment Schedule with hp, rpm, efficiency TR FOR' • E'S (Section 1540 1540 Transformers Indicate size and efficiency If "no' is circled for any question, provide explanation: oPERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1015 DATE: 07 -18 -08 PROJECT NAME: MARC ECKO CUT & SEW SITE ADDRESS: 837 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 4 ctb Bu +Ing'Division X Public Works n Fire Prevention n Planning Division Structural Permit Coordinator n DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07 -22-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-19-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page 0 • Page 1 of 2 Electrical Contractor A business licensed by LFtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. ABACUS ELECTRIC CO Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ABACUS ELECTRIC CO 2539841611 9804 SALES RD S SUITE A- 1 LAKEWOOD WA 98499 PIERCE LIMITED LIABILITY COMPANY ABACO CONTRACTORS LLC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602838703 ACTIVE ABACUEC928LT ELECTRICAL CONTRACTOR 6/30/2008 6/30/2010 OUELLMR96050 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License OUELLMR96050 Name OUELLETTE, MARK R Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MOSS, HAYWOOD TROY PARTNER /MEMBER 06/30/2008 SMITH, SHANE PARTNER /MEMBER 06/30/2008 http s: / /fortress.wa. gov /lni/bbip/Detai 1. aspx ?License= ABACUEC928LT 08/15/2008 ELECTRICAL SYMBOLS LIGHT FIXTURE DESCRIPTION MOUNTING WIRING DEVICE DESCRIPTION MOUNTING COMMUNICATIONS DESCRIPTION OUNTING SURFACE FLUORESCENT, NORMAL POWER SURFACE FLUORESCENT, EMERGENCY POWER RECESSED FLUORESCENT, NORMAL POWER RECESSED FLUORESCENT, EMERGENCY POWER WALL MOUNTED EXIT SIGN, SHADING INDICATES THE ILLUMINATED FACES CEILING MOUNTED EXIT SIGN, SHADING INDICATES THE ILLUMINATED FACES /I I` BATTERY PACK, NORMAL POWER BATTERY PACK, EMERGENCY POWER POLE, BASE AND FIXTURE(S). CIRCLES INDICATE # OF HEADS PER POLE, NORMAL POWER POLE, BASE AND FIXTURE(S). CIRCLES INDICATE # OF HEADS PER POLE, EMERGENCY POWER I-O WALL MOUNTED FIXTURE AND BRACKET, NORMAL POWER I-.• WALL MOUNTED FIXTURE AND BRACKET, EMERGENCY POWER STRIP FIXTURE, NORMAL POWER STRIP FIXTURE, EMERGENCY POWER O SURFACE MOUNTED DOWNLIGHT, NORMAL POWER • SURFACE MOUNTED DOWNLIGHT, EMERGENCY POWER O RECESSED DOWNLIGHT, NORMAL POWER 600W Iw• Y Y RECESSED DOWNLIGHT, EMERGENCY POWER RECESSED WALL WASHER, NORMAL POWER RECESSED WALL WASHER, EMERGENCY POWER TRACK FIXTURES AND TRACK ASSEMBLY, NORMAL POWER TRACK FIXTURES AND TRACK ASSEMBLY, EMERGENCY POWER SWITCH, WHERE "X" CAN BE ONE OF THE FOLLOWING: 2= 3= 4= K= LV = MC = OS = (blank) = DOUBLE POLE THREE WAY FOUR WAY KEYED LOW VOLTAGE MOMENTARY WITH RTC OCCUPANCY SENSOR SINGLE POLE DIMMER SWITCH, OPERATING WATTAGE INDICATED SWITCH WITH PILOT LIGHT OCCUPANCY SENSOR, WHERE "Y" IS THE RATED AREA OF COVERAGE AND "X" IS ONE OF THE FOLLOWING: DT = DUAL TECHNOLOGY US = ULTRASONIC PIR = PASSIVE INFRARED 96" AFF or 8" BFC 96" AFF or 8" BFC 96" AFF or 8" BFC 46" 46" 46" x x RECEPTACLE OPTIONS DENOTED BY "X ", WHERE "X" CAN BE ONE OF THE FOLLOWING: IG = ISOLATED GROUND GFI = GROUND FAULT INTERRUPTER TR = TAMPER RESISTANT SS = SURGE SUPPRESSOR WP = WEATHERPROOF (blank) = STANDARD RECEPTACLE SIMPLEX RECEPTACLE, NORMAL POWER DUPLEX RECEPTACLE, NORMAL POWER DUPLEX RECEPTACLE, UPS POWER DUPLEX RECEPTACLE, EMERGENCY POWER 18" 18" 18" 18" FOURPLEX RECEPTACLE 18" O FLOOR OUTLET BOX, POWER, VOICE AND /OR DATA ©10 -30R SPECIAL PURPOSE RECEPTACLE, 18" WITH NEMA CONFIGURATION NOTED PS -A MULTIOUTLET ASSEMBLY, REFER TO SPEC FOR TYPE AND RECEPTACLE SPACING ❑J DISCONNECT SWITCH, NON -FUSED aJ DISCONNECT SWITCH, FUSED I(MS Iu)MSS EF -1 ® EQUIPMENT NUMBER INDICATED MOTOR STARTER SWITCH WITHOUT OVERLOAD PROTECTION MOTOR STARTER SWITCH IMTH OVERLOAD PROTECTION MAGNETIC MOTOR STARTER WITH EF -1 AHU 1 COMBINATION MOTOR STARTER AND FUSED DISCONNECT WITH EQUIPMENT NUMBER INDICATED EQUIPMENT TAG (REFER TO EQUIPMENT SCHEDULE) 208/120 VOLT PANELBOARD 480/277 VOLT PANELBOARD TERMINAL CABINET ANNUNCIATOR PANEL 54" 54" It H INTERCOM - DESK INTERCOM - WALL TELEPHONE - DESK TELEPHONE - WALL HOUSE PHONE VOICE /DATA OUTLET TECHNOLOGY OUTLET (REFER TO SPE I-D BELL BUZZER FEYI CHIME I fl TELEVISION RECEIVER FEN MICROPHONE OUTLET LINE LEVEL OUTLET I n L FP DES RC FE MS ASR OAT 1 ®AT ©t VOLUME CONTROL, ZONE NUMBER INDICATED PROJECTOR OUTLET EFFECTS SPEAKER OUTLET REMOTE CONTROL MONITOR SPEAKER OUTLET SOUND REINFORCEMENT OUTLET SPEAKER, CEILING MOUNTED WITH TYPE AND ZONE NUMBER INDICATED (REFER TO SPECIFICATION FOR TYPE) SPEAKER, WALL MOUNTED WITH TYPE AND ZONE NUMBER INDICATED (REFER TO SPECIFICATION FOR TYPE) SPEAKER RE- ENTRANT HORN WITH ZONE NUMBER INDICATED 18" 54" 18" 54" 54" 18" 18" 80" 80" 80" 18" 18" 18" 46" 18" 6" BFC v v v v v PANEL LA Location: Stockroom A.I.C. 10,000 208/120 Volt, 30, 4w Main: MCB 150A Mounting: Surface Circuit Description KVA CB NO. HL A B C HL NO. CB KVA Circuit Description SALES LTG - TRACK 1.8 20/1 1 1.0 X HVAC 11.1 0.9 2 20/1 0.4 SALES RECPT. - SHOW WINDOW SALES LTG - TRACK 1.8 20/1 3 40.4 X 50.1 4 20/1 0.6 SALES RECEPTACLES SALES LTG - TRACK 1.8 20/1 5 X 6 20/1 0.6 SALES RECEPTACLES SALES LTG - TRACK 1.5 20/1 7 X 8 20/1 0.2 SALES RECEPTACLES SALES LTG - TRACK 1.8 20/1 9 X * 10 20/1 0.4 CASH WRAP RECEPTACLES SALES LTG - TRACK 1.8 20/1 11 X * 12 20/1 0.4 CASH WRAP RECEPTACLES SALES LTG - TRACK 1.8 20/1 13 X * 14 20/1 0.4 CASH WRAP RECEPTACLES SALES LTG - TRACK 1.8 20/1 15 X * 16 20/1 0.2 SECURITY SALES LTG - TRACK 1.2 20/1 17 X 18 20/1 0.2 TOILET GFI SALES LTG - TRACK 1.2 20/1 19 X 20 20/1 1.5 WATER HEATER SALES LTG - SHOW WINDOW 0.2 20/1 21 X 22 20/1 0.6 STOCKROOM RECEPTACLES SALES LTG - ENTRY 0.2 20/1 23 X 24 20/1 0.7 MANAGERS DESK SALES LTG - EMERGENCY 0.3 20/1 25 * X 26 20/1 0.7 MANAGERS DESK SALES LTG 0.4 20/1 27 X * 28 20/1 0.2 PHONE BOARD DRESSING LTG 0.6 20/1 29 X * 30 20/1 SPARE STOCK ROOM LTG 0.8 20/1 31 * X 32 20/1 SPARE SIGN 0.8 20/1 33 X 34 20/1 SPARE SPARE 20/1 35 X 36 20/1 SPARE VAV -1 3.7 40/3 37 X 38 20/1 SPARE 39 X 40 20/1 SPARE 3.7 41 X 42 20/1 SPARE 3.7 CONNECTED KVA: 38.0 A 14.3 B 12.5 C 11.2 DESIGN DEMAND KVA: 40.4 CONNECTED AMPS: 119.2 DESIGN DEMAND AMPS: 112.1 BALANCE PHASE LOADS TO WITHIN 10% OF EACH OTHER. ( *) INDICATES BREAKER TO BE LOCKED ON. LOAD SUMMARY CONNECTED KVA DESIGN FACTOR DESIGN DEMAND KVA LIGHTING 2.5 0.95 2.4 TRACK LIGHTING 16.5 1.0 16.5 RECEPTACLES 5.2 1.0 5.2 SIGN 0.8 1.0 0.8 WATER HEATER 3.6 1.0 3.6 HVAC 11.1 0.9 10.0 MISCELLANEOUS 1.9 1.0 1.9 TOTAL KVA: 41.6 40.4 TOTAL AMPS: 50.1 48.6 SERVICE KVA: 40.4 1.25 50.5 SERVICE AMPS: 60.7 FIRE ALARM DESCRIPTION MOUNTING MISCELLANEOUS DESCRIPTION MOUNTING Fo FE EPO It HD JUNCTION BOX, RECESSED WALL JUNCTION BOX, RECESSED CEILING CLOCK, WALL MOUNTED CLOCK, CEILING MOUNTED LINE VOLTAGE THERMOSTAT PUSHBUTTON EMERGENCY POWER OFF PUSHBUTTON TIME SWITCH CONTACTOR 96" or 8" BFC 58" 46" 46" BRANCH CIRCUITING DESIGN PRESENTATION DESCRIPTION 1 KEY NOTE, REFER TO LIST OF KEY NOTES ON THE SAME PLAN 1 FEEDER NOTE, REFER TO FEEDER SCHEDULE ON THE SAME PLAN QDRAWING REVISION NOTE CONCEALED RACEWAY RACEWAY INSTALLED IN FLOOR OR BELOW FINISHED GRADE EXPOSED RACEWAY RACEWAY UP RACEWAY DOWN CONDUIT STUB, BUSHED AND CAPPED UNDERFLOOR DUCT, POWER AND I - -- COMMUNICATIONS RACEWAYS LP -1 -1 ---- PANEL NAME 1,3,5 CIRCUIT NUMBER(S) GROUND CONDUCTOR f- NEUTRAL CONDUCTOR PHASE CONDUCTORS 3/4" CONDUIT AND WIRE SIZE N(1/2" C OTED OTHERWISE) __LIGHT ERWISE) LIGHT FIXTURE DESIGNATOR, REFER TO LIGHT �-� A"-- FIXTURE SCHEDULE FOR TYPE AND VOLTAGE a CIRCUIT NUMBER SWITCH LEG ©/ ©/ ©• FIRE ALARM DEVICE, WHERE "X" CAN BE ONE OF THE FOLLOWING: (blank) H P DS FL B -T B -R RB MM CM D MR TS VDT PR FIRE ALARM MANUAL PULL STATION 46" FIRE ALARM MANUAL KEYED STATION 46" IONIZATION DETECTOR THERMAL DETECTOR PHOTOELECTRIC SMOKE DETECTOR DUCT SMOKE DETECTOR SPRINKLER VALVE FLOW SWITCH BEAM DETECTOR, TRANSMITTER BEAM DETECTOR, RECEIVER ROTATING BEACON MONITOR MODULE CONTROL MODULE MAGNETIC DOOR HOLDER SHUTTER /ROLLING DOOR RELEASE DUCT DETECTOR REMOTE TEST STATION 80" VIDEO DISPLAY TERMINAL & KEYBOARD SYSTEM EVENT PRINTER FIRE ALARM HORN FIRE ALARM SPEAKER FIRE ALARM STROBE FIRE ALARM HORN WITH STROBE FIRE ALARM MINI -HORN WITH STROBE FIRE ALARM SPEAKER WITH STROBE FIREFIGHTER PHONE JACK FIRE ALARM BELL FIRE ALARM CHIME FIRE ALARM CHIME WITH STROBE SPRINKLER VALVE POSITION SWITCH 80" 80" 80" 80" 80" 80" 46" 80" 80" 80" ELECTRICAL SHEET INDEX EO TITLE SHEET & SCHEDULES El LIGHTING PLAN E2 POWER PLAN E3 SPECIFICATIONS 0 REVIEWED (CODE COMPLIANCE NPPA. 70 - NEC UL 29 (IN 4 City et B ILDIN D COPY Permit No I41 ila N Pia, review cpproval Is subject to errors and omissions. Appr .)val of construction documents does not authorize the violation of any adopted code or ordirtence" Receipt of approved Fiei Copy and : is Acknowledged: By Date: Ceti of Tukwila 13U'!..DiNG DIVISION REVISIONS No changes shall be made to thel scope Of work without prior app Tukwila Building Division. NOTE: Revisions additional plan rEva submittal and may inc Qw fees ' iimiammomm DATE: 07/08/08 JOB NO: DRAWN: MDR CHECKED: SOR 08- 0196.004 • 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 Project Coordination By: Go Ifl d a ,,■ L v e V 4J C rfEi . 6 • . > a on v c ro b Y C.,, t.9 tr3 J o irmi E itt I1 • .o CO irt 1- b L 412.243.3430 • co J � co Q r WZZ Q��g Njj 00 _ M M O SEPARATE PERMIT REQUIRED FOR: Itemethanicat ❑ Electrical Plumbing 461 Gas Piping City of Tukwila BUILDING DIVISION RE4 CITY EC OF EIV TUK LA JUL 18 Z008 PERMIT CENTER ENGINEERINC ' c;4~ Mechanical /El icpkr- o!3uIting Engineers 1750 Commerce`Court; Whfte'lieartake; MN- 51tt0" (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS 1. LANDLORD REVISIONS - 07/10/08 TITLE SHEET AND SCHEDULES SHEET NUMBER EO A4 OLA -3 EL- LA -25 A2 O O LA-3 8' A 4' LA -3 , A O OA -3 8' O 4' A2 OLA-1 ,4' . O 8' A O OLA-1 .8' EL LA -25 A2 9 LA-1 9 4' A4 LA -19 iO LA -31 F LA -31 EL LA -31 EL LA -31 BO LA -27 OB LA -27 • - -23 EEC LA -31 A4 LA -9 A4 LA -13 LA -31 BO LA -27 0 LA -27 A4 LA -19 ES LA -25 F LA -31 A4 OLA -25 A4 LA -17 LA -33.6' LA -33 OD LA- 33.690 8' Fr LA -31 25 A(4) % LA -9 8' A(4) % LA -9 EL LA -25 8' A(4) 7 8, A(2) % 4' LA -7 LA -7 ' A• (4) LA -7 .. 8 A(4) / LA -5 8' 8 A(4) / 0 8' A(2) % 4' LA -5 LA -5 EL LA— 25 LIGHTING PLAN 1/4" = 1' -0" DATE: JOB NO: 07/08/08 08- 0196.004 DRAWN: MDR CHECKED: SOR Project Coordination By: 10 u 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 GENERAL NOTES REFLECTED CEILING FIXTURE LEGEND A. SYMBOL TYPE MFR. PRODUCT NO. FINISH DESCRIPTION LAMPING MTG. METHOD MTG. HGT. VOLTS COMMENTS T# TRACK CON —TECH LT -4 —P, LT -8 —P, LT -12 —P WHITE SURFACE MTD. TRACK SURFACE 11' -5" 120 9 A AME UX LT -20 —M — E —WT —C • — 120 —NF HITE ACCENT CDM20 /T /830 RACK 11' -5" 120 LT = TRACK LENGTH, REFER TO ELECTRICAL DWGS. FOR TRACK LENGT SURFACE MOUNTED; 1 CIRCUIT TRACK X IX • = Mi 1 2 I M.- OLs' ADJUS : E ACC ► LIGH ECTR• ' BALLA , 120V, • RROW BEAM DISTRIBUTOR, WHITE `r XTURE FINISH • EMX ISI EEU —U —R —W WHITE DUAL HEAD EMERGENCY LIGHT/ EXIT SIGN COMBO LED/ HALOGEN LAMPS INCLUDED WALL SEE COMMENTS 120 ELECTRICAL CONTRACTOR TO REFER TO ARCHITECTURAL DRAWINGS FOR ALL LIGHT FIXTURE LOCATIONS. B. CONTRACTOR SHALL COMPLETELY REMOVE ALL EQUIPMENT, PANELBOARDS, DEVICES, FIXTURES, WIRING, CONDUIT, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. EY NOTES DUAL HEAD EMERGENCY LIGHT /EXIT SIGN COMBO — 90 MINUTE BATT POWER, WHITE, MOUNT 1" BELOW CEILING OR HIGHEST POINT ON WA O D EL RLU AMERLUX ISI E2.9• = i -MM- W RA4- 39— T6— E —SD —C- 120 —CL EE -1 CLEAR WHITE RI. ADJ RECESSED STOREFRONT ACCFNT DUAL HEAD EMERGENCY LIGHT E C� e 6 C CDM39/T6/830 LED/ HALOGEN LAMPS INCLUDED RECESSED WALL TIGHT TO CLG. 120 120 M VO 2.• RO NLIGHT AMERLUX ROUND RECESSED ADJUSTABLE, 39W T6 METAL HALIDE DO LIGHT, SPOT, SEMI — DIFFUSE CLEAR TRIM DUAL HEAD EMERGENCY LIGHT — 90 MINUTE BATTERY POWER, WHITE (9 ES ISI PINN— R— SP— SW— UA -1 —W WHITE EXIT SIGN LED (INTEGRAL) SURFACE/ WALL SEE INTERIOR ELEVATIONS 120 ISI PINNACLE EDGE —LIT EXIT SIGN SELF — POWERED 90 MINUTE BACKUP, CEILING RECESSED, UNIVERSAL ARROWS, 1 FACE, WHITE BACKGROUND F 0 FL( #) MERCURY FIXTURE BY REJUVENATION BULB BY FERROWATT MIE6- 232— OCT— ELB -120V WHITE STRIP LIGHT (2)F32T8/730 PENDANT 11, -0" 120 FIXTURE: AA9479 — BRONZE W/ MAROON CORD (FL1 =36 "L CORD, FL2 =30" CORD & FL3= 24" CORD); BULB: 1910N SQUIRRELCAGE FILAMENT BRONZE PENDANT FITTING ROOM LIGHT (1) 40 WATT BULB PER FIXTURE PENDANT VARIES, COORDINAT W/ CORD LENGTH E120 MERCURY 4' -0" 2 LAMP 32W OCTRON T8 INDUSTRIAL FLUORESCENT WITH SYMMETRICAL REFLECTOR, ELECTRONIC BALLAST, 120V, WHITE MAKE 120V CONNECTIONS TO STORE FRONT SIGN. VERIFY EXACT LOCATION. © PROVIDE CONNECTION TO CEILING EXHAUST FAN /LIGHT COMBINATION. FAN AND LIGHT TO BE CONTROLLED BY COMMON SWITCH. <> ELECTRICAL SERVICE EQUIPMENT LOCATION. REFER TO SHEET E2, POWER RISER DIAGRAM AND PANELBOARD SCHEDULES. <> THE STOREFRONT CIRCUITS NOTED (LA -21, 23, &33) ARE TO BE CONTROLLED BY THE TIME CLOCK. COORDINATE EXACT SCHEDULING FORMAT WITH LANDLORD. €:: SPEAKER AND WIRING PROVIDED BY TENANT'S VENDOR. ONLY IF REQUIRED BY MALL STANDARDS OR LOCAL CITY /BUILDING CODES, TENANT'S E.C. SHALL INSTALL 3/4" CONDUIT WITH PULLSTRING FROM EACH SPEAKER LOCATION TO A POINT DETERMINED BY AUDIO SUPPLIER AND BACK TO MANAGER'S DESK. COORDINATE EXACT SPEAKER TYPE, QUANTITIES AND LOCATIONS PRIOR TO ROUGH —IN. 6 NOT USED. 7 THIS LENGTH OF TRACK SHALL BE ON THE EMERGENCY /NIGHT LIGHTING CIRCUIT, LA -25. REJUVENATION 'BURNSIDE' CLASSIC CLOTH— COVERED CORD PENDANT CORD, 40 WATTT FERROWATT CANOPY SQUIRRELCAGE FILAMENT BULB 0 F2 SPECTRUM SP4VF132E1 /4410SG POLISHED CHROME RECESSED STOREFRONT ACCENT U FL— CF32 /TC /730 RECESSED 9' -0" 120 SPECTRUM 4" DIAMETER, 32W COMPACT FLUORESCENT DOWNLIGHT, SOFT GLOW REFLECTOR, 120V M CUSTOM SALES AREA CHANDELIER (4) 60 WATT (MAX.) INCANDESCENT LAMP PENDANT 9' -0" B.O. FIXTURE 120 0 SP BLACK SPEAKER SURFACE/ WALL TIGHT TO CLG. CUSTOM SALES AREA CHANDELIER LIGHT FIXTURE SUPPLIED BY OWNER & INSTALLED BY G.C. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION RECESSED CEILING MOUNTED SPEAKER SUPPLIED BY A/V VENDOR INSTALLED BY G.C. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. RECEIVED CITY OF TUKWILA JUL 181008 PERMIT CENTER 8�t, HALLBE . ;f %�`: ENGINEERI GIP.k,; For; Mechanical /Ele cal •Consulting Engineers 1750 Commerc Court;�Whfeieartake;iN--55t1 (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS 1. LANDLORD REVISIONS - 07/10/08 LIGHTING PLAN SHEET NUMBER E1 10 LV 67_ LA -22 Cal -26 LA -22 05cd• LA -4 L H 11ocd A 120" A.F.F. LA -8 VAV -1 LA- 37,39,41 1 "C. -3 #8 LA -6 111 III n 111 111 LANDLORD GENERAL NOTES: (x.3) POWER PLAN 1 1/4" = 1' -0" NO BX, AC, OR ROMEX TYPE WIRING ALLOWED. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED, HANGERS,CLAMPS AND SUPPORTS SHALL BE FASTEND TO BAR JOISTS OR BEAMS ONLY. ALL CABLING SHALL BE PLENUM RATED. ALL TENANT'S SERVED BY LANDLORDS AIR CONDITIONING UNITS HAVE PLENUM RETURNS. INSTALL A COMPLETE TYPE WRITTEN IDENTIFICATIONDIRECTORY CARD FOR ALL BRANCH CIRCUITS IN THE PANEL DOOR. 1" CONDUIT 1" CONDUIT MANAGER'S DESK TELEPHONE BOARD BACK WRAP NOTE: ELECTRICAL CONTRACTOR SHALL REUSE ANY EXISTING ELECTRICAL DISTRIBUTION EQUIPMENT IF IT COMPLIES WITH CODE AND IS OF SUFFICIENT CAPACITY. LEASE LINE LANDLORD ELEC. ROOM TENANT'S SPACE 1" CONDUIT TRENCHED OR CO 'E BORED TO CASH WRAP CABINE CASH WRAP TELEPHONE CONDUIT DIAGRA 4 / NTS 0 (2) POWER RISER DIAGRAM RISER DIAGRAM NOTES O1 EXISTING LANDLORD 277/480V, 3PH, 4W ELECTRICAL DISTRIBUTION. FIELD VERIFY PRIOR TO BID. O2 LANDLORD PROVIDED MASTER METERING EQUIP. IN LANDLORD'S ELECTRICAL ROOM. O3 LANDLORD TO PROVIDE FUSED DISC. SWITCH. COORDINATE EXACT REQUIREMENTS WITH LANDLORD PRIOR TO BID. LANDLORD TO PROVIDE 1 1/4" C. 4 #3 CONDUIT FROM LANDLORD'S MAIN DISTRIBUTIONTO TENANT'S DEMISED PREMISES. COORDINATE EXACT REQUIREMENTS WITH LANDLORD PRIOR TO BID. MAIN FUSED DISCONNECT. NOT USED. TENANT'S E.C. TO PROVIDE PANEL LA. REFER TO PANEL SCHEDULES ON SHEET E0. PROVIDE 2 "C. 4#1/0 & 1#6 GND. TENANT'S E.C. TO PROVIDE COPPER GROUND PER NEC. TENANT'S E.C. TO PROVIDE NEW 45 KVA, 480V, 3PH, 3W — 208/120V, 3PH, 4W TRANSFORMER. 10 LANDLORD TO PROVIDE 480 VOLT, 30, 100A FUSED DISCONNECT SWITCH, FUSE AT 80 AMPS. PROVIDE 1-1/4"C. 3 #4 & 1#8 GND. TENANT'S ELEC. CONTRACTOR WILL PROVIDE A I.D. NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. LA -2 1I) LA -16 QJ 10 LA -6 REVIEWED CODE NPPA 70 - NEC JUL 2 9 2008 City Of Tukwila DIVY GENERAL NOTES A. CONTRACTOR SHALL COMPLETELY REMOVE ALL EQUIPMENT, PANELBOARDS, DEVICES, FIXTURES, WIRING, CONDUIT, ETC. AND ALL ASSOCIATED SUPPORTS, BRACING, PADS, ETC. NOT BEING REUSED OR SHOWN TO REMAIN WHETHER IN THE DEMISED SPACE, ON THE ROOF OR OTHERWISE LOCATED OUTSIDE OF THE DEMISED SPACE. DO NOT ABANDON IN PLACE. KEY NOTES O1 PROVIDE CONDUITS WITH PULL WIRE BACK TO MANAGER'S DESK IN STOCKROOM. 1" MINIMUM, BUSH CONDUIT'S ENDS. 22 TRENCH OR CORE BORE CONDUIT AND WIRE AS SHOWN. VERIFY ANY REQUIREMENTS WITH LANDLORD PRIOR TO BID. IF MORE THAN ONE (1) CONDUIT, CONDUIT SHALL BE IN COMMON TRENCH. O3 CONDUIT SHOWN SOLID TO BE SURFACE MOUNTED ON FLOOR IN SPACE BELOW CASEWORK FROM STUB —UP LOCATION TO CASH REGISTER DEVICE LOCATIONS. REFER TO KEY NOTE #2. O4 THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSES. THE CIRCUITS SHALL NOT SHARE THE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE THE CONDUIT FOR GROUNDING. ELECTRONIC CASH REGISTER OUTLETS SHALL BE HUBBELL NO. IG -5362, OR APPROVED EQUAL. ISOLATED GROUNDING CONDUCTOR SHALL TERMINATE WHERE THEY RECIVE THEIR SOURCE. INSTALLATION SHALL COMPLY WITH N.E.C. ARTICLE 250.146(D). 05 MAKE CONNECTION TO 120V, 1.5 KW WATER HEATER. MOUNT DISCONNECTING MEANS ADJACENT TO WATER HEATER. VERIFY EXACT LOCATION. 40. ELECTRICAL SERVICE EQUIPMENT LOCATION. INSTALLATION MUST COMPLY WITH N.E.0 ARTICLE 240.24(C) AND (D). O7 SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340- 4G5 -24VAC BUZZER, ONE (1) BUZZER LOCATED AT BACK WRAP WALL AND ONE (1) BUZZER NEXT TO MANAGER'S DESK, 852 WEATHERPROOF PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT, UNLESS REQUIRED BY THE LANDLORD OR LOCAL AUTHORITY. REUSE EXISTING IF APPLICABLE. O8 LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR THE TENANT'S USE.(NO CONDUIT WILL BE PROVIDED) LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVICE TELEPHONE COMPANY. ALL TENANT TELEPHONE WILL BE CONTAINED WITHIN THE TENANT'S SPACE. ANY CORRIDOR PENATRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. O9 LANDLORD SHALL FURNISH AND INSTALL (ONE) FIRE ALARM J —BOX INSIDED THE DEMISED PREMISES FOR EACH TENANT'S USE CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL IF NECESSARY INITIATION DEVICES, ANNUCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. TENANT SJALL CONTRACT WITH LANDLORD'S DESIGNED FIRE ALARM CONTRACTOR FOR DESIGN,PROGRAMMING AND FINAL CONNECTION TO LANDLORDS FIRE ALARM AT TENANT'S EXPENSE. TENANT SHALL ONLY USE LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATABILITY WITH LANDLORDS FIRE ALARM SYSTEM. A COPY OF ALL DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHALL. • PROVIDE J —BOX IN ACCESSIBLE CEILING SPACE FOR SECURITY SYSTEM. COORDINATE EXACT REQUIREMENTS WITH SECURITY SYSTEM SUPPLIER PRIOR TO BID. NO CORD AND PLUG CONNECTIONS ALLOWED ABOVE CEILING. 11 TIME CLOCK: PARAGON MODEL 7000 — SERIES OR EQUAL WITH 7 DAY, 24 HOUR SCHEDULING FORMAT, MIN. (4) N.O. 20 AMP, 120/277 VOLT CONTACTS, 120 VOLT COIL AND SPRING WOUND RIDE THROUGH. SWITCH SHALL CONTROL STORE FRONT LIGHTING AND SIGN LIGHTING OR CONTACTOR(S) AS REQUIRED. • PROVIDE RECESSED FLUSH WHITE DUPLEX RECEPTACLE AT SHOW WINDOW CEILING. 13 NEW 208V/30 VAV BOX (VAV- 1)WITH ELECTRICAL HEAT BY MECHANICAL CONTRACTOR. PROVIDE 60A/3P/30 DISCONNECT SWITCH WITH (3) 40A FUSES. • PROVIDE CALL —FOR —AID BOX IN HANDICAPPED RESTROOM. I M N DATE: JOB NO: 07/08/08 08- 0196:004 DRAWN: MDR CHECKED: SOR M 0 ARCHITECT 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 RECEIVED C ITY OF TUKWILA JUL 18 2008 ERMIT CENTER 00 00 CO rn -r , �-�i �–' - ') HYecAanLlcal L/Elec B Nits ' ENGINEERIN 1750 Commerce Co F _Wr_taker- (651) 748 -1100 • Fox (651) 748 -9370 REVISIONS 1. LANDLORD REVISIONS - 07/10/08 POWER PLAN SHEET NUMBER E2 16010 - GENERAL PROVISIONS A. WORK CONSISTS OF FURNISHING LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF ELECTRICAL WORK SHOWN IN THE CONTRACT DOCUMENTS AND SPECIFIED IN DIVISION 16. B. INCLUDE ALL PARTS AND LABOR, WHICH ARE INCIDENTAL AND NECESSARY FOR A COMPLETE AND OPERABLE INSTALLATION EVEN THOUGH NOT SPECIFICALLY MENTIONED IN THE CONTRACT DOCUMENTS. SUCH ITEMS INCLUDE NUTS, BOLTS, ANCHORS, BRACKETS, SLEEVES, OFFSETS IN CONDUIT, FITTINGS, RELAYS, ETC. C. ARRANGE WITH LANDLORD TO PROVIDE TEMPORARY AND PERMANENT UTILITY SERVICES AS REQUIRED AND COORDINATE THEIR INSTALLATION WITH CONSTRUCTION PROGRESS OF THIS PROJECT. PAY ALL r :. T AND COSTS CHARGED BY UTILITY COMPANIES FOR UTILITY SERVICES. D. OBTAIN ALL TEMPORARY AND PERMANENT PERMITS AND LICENSES REQUIRED IN CONNECTION WITH THIS DIVISION'S WORK. PAY ALL FEES AND EXPENSES REQUIRED FOR SUCH PERMITS AND LICENSES. E. REQUEST INSPECTIONS AS REQUIRED BY REGULATING AGENCIES AND /OR REGULATIONS. PAY ALL CHARGES FOR INSPECTIONS BY REGULATING AGENCIES OF INSTALLATIONS OF PLANS AND SPECIFICATIONS. F. INCLUDE STATE AND LOCAL SALES TAXES IN THE BID. KEEP ACCURATE RECORDS OF THESE TAXES AND FURNISH SUCH RECORDS TO THE TENANT UPON REQUEST. G. MEET OR EXCEED ALL CURRENT APPLICABLE CODES, ORDINANCES AND REGULATIONS FOR ALL INSTALLATIONS. PROMPTLY NOTIFY THE ENGINEER, IN WRITING, IF THE CONTRACT DOCUMENTS APPEAR TO CONFLICT WITH GOVERNING CODES AND REGULATIONS. CONTRACTOR ASSUMES ALL RESPONSIBILITY AND COSTS FOR CORRECTING NON - COMPLYING WORK INSTALLED WITHOUT NOTIFYING THE ENGINEER. H. HIGHER QUALITY OF WORKMANSHIP AND MATERIALS INDICATED IN THE CONTRACT DOCUMENTS TAKES PRECEDENCE OVER THAT ALLOWED IN REFERENCED CODES AND STANDARDS. I. THE TERMS DEFINED BELOW APPLY TO ALL WORK INCLUDED IN DIVISION 16. 1. THE WORK - AS DEFINED IN THE 1997 NA DOCUMENT A201: `THE TERM WORK' MEANS THE CONSTRUCTION AND SERVICES REQUIRED BY THE CONTRACT DOCUMENTS WHETHER COMPLETED OR PARTIALLY COMPLETED, AND INCLUDES ALL OTHER LABOR MATERIALS, EQUIPMENT AND SERVICES PROVIDED OR TO BE PROVIDED BY THE CONTRACTOR TO FULFILL THE CONTRACTOR'S OBLIGATIONS. THE WORK MAY CONSTITUTE THE WHOLE OR A PART OF THE PROJECT." 2. FURNISH - TO OBTAIN IN NEW CONDITION READY FOR INSTALLATION INTO THE WORK. 3. INSTALL - TO STORE, SET IN PLACE, CONNECT AND PLACE INTO OPERATION INTO THE WORK. 4. PROVIDE - TO FURNISH AND INSTALL. 5. CONNECT - TO BRING SERVICE TO THE EQUIPMENT AND MAKE FINAL ATTACHMENT INCLUDING NECESSARY SWITCHES, OUTLETS, BOXES, TERMINATIONS, ETC. 6. CONDUIT - INCLUDES IN ADDITION TO CONDUIT, ALL FITTINGS, PULL BOXES, HANGERS AND OTHER SUPPORTS AND ACCESSORIES RELATED TO SUCH CONDUIT. 7. CONCEALED - HIDDEN FROM SIGHT IN CHASES, FURRED SPACES, SHAFTS, HUNG CEILINGS, EMBEDDED IN CONSTRUCTION, IN CRAWL SPACES OR BURIED. 8. EXPOSED: NOT INSTALLED UNDERGROUND NOR CONCEALED AS DEFINED ABOVE. J. THE DRAWING AND SPECIFICATIONS CONSTITUTE THE CONTRACT DOCUMENTS. ANY ITEM NOTED IN THE SPECIFICATION OR SHOWN ON THE DRAWINGS IS INCLUDED IN THE CONTRACT DOCUMENTS. K. ALL ELECTRICAL DETAILS AND DRAWINGS ARE DIAGRAMMATIC, UNLESS SPECIFICALLY NOTED. FIELD VERIFY ALL DIMENSIONS AND NOTIFY THE ENGINEER OF ANY CONFLICTS OR DISCREPANCIES, IN WRITING, PRIOR TO INSTALLATION. L. INITIATE, MAINTAIN AND SUPERVISE ALL SAFETY PRECAUTIONS REQUIRED WITH THIS WORK IN ACCORDANCE WITH THE REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) AND OTHER GOVERNING AGENCIES. M. DO NOT REMOVE OR DISTURB ANY ASBESTOS CONTAINING MATERIALS FROM THE PROJECT. IMMEDIATELY STOP WORK AND NOTIFY THE TENANT IF ASBESTOS CONTAINING MATERIALS ARE SUSPECTED. N. BEFORE SUBMITTING A PROPOSAL ON THE WORK CONTEMPLATED, EXAMINE THE SITE OF THE PROPOSED WORK AND BECOME THOROUGHLY FAMILIAR WITH EXISTING CONDITIONS AND LIMITATIONS. NO EXTRA COMPENSATION WILL BE ALLOWED BECAUSE OF MISUNDERSTANDING AS TO THE AMOUNT OF WORK INVOLVED NOR BIDDERS LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHICH COULD HAVE BEEN DISCOVERED OR REASONABLY ANTICIPATED PRIOR T O BIDDING. 0. CONDUITS, PIPES, DUCTS, LIGHTS, DEVICES, SPEAKERS, ETC., SHOWN ON THE DRAWINGS AS EXISTING HAVE BEEN BASED ON EXISTING PLANS AND MAY NOT BE INSTALLED AS ORIGINALLY TO SITE AND MAKE EXACT CONTRACTORS RESPONSIBILITY T VI SIT THE SHOWN. I T IS THE CONTRA DETERMINATION OF THE EXISTENCE, LOCATION AND CONDITION OF SUCH FACILITIES PRIOR TO SUBMITTING A BID. P. CONSULT THE DRAWINGS AND SPECIFICATIONS OF MECHANICAL AND OTHER TRADES FOR CORRELATING INFORMATION AND LAY OUT WORK SO THAT IT WILL COORDINATE WTH OTHER TRADES. VERIFY DIMENSIONS AND CONDITIONS (I.E., FINISHED CEILING HEIGHTS, FOOTING AND FOUNDATION ELEVATIONS, BEAM DEPTHS, ETC.) WITH THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. NOTIFY THE ARCHITECT /ENGINEER OF ANY CONFLICTS THAT CANNOT BE RESOLVED, IN THE FIELD, BY AFFECTED TRADES. REPLACEMENT OF WORK DUE TO LACK OF COORDINATION AND FAILURE TO VERIFY EXISTING CONDITIONS WILL BE COMPLETED AT NO COST TO THE TENANT. Q. INSTALL ALL CONDUIT, CABLE TRAY, BUSDUCT, EQUIPMENT, ETC. ALLOWING PROPER CODE AND MAINTENANCE CLEARANCES AND TO AVOID BLOCKING PASSAGEWAYS AND ACCESS PANELS. R. WHERE WORK MUST BE REPLACED DUE TO THE FAILURE OF THE CONTRACTOR TO VERIFY THE CONDITIONS EXISTING ON THE JOB, SUCH REPLACEMENT MUST BE ACCOMPLISHED AT NO COST TO THE TENANT. THIS APPLIES TO SHOP FABRICATED WORK AS WELL AS TO WORK FABRICATED IN PLACE. S. THROUGHOUT THE COURSE OF THE WORK, MINOR CHANGES AND ADJUSTMENTS TO THE INSTALLATION MAY BE REQUESTED BY THE ENGINEER. THE CONTRACTOR SHALL MAKE ADJUSTMENTS WITHOUT ADDITIONAL COST TO THE TENANT, WHERE SUCH ADJUSTMENTS ARE NECESSARY TO THE PROPER INSTALLATION AND OPERATION WITHIN THE INTENT OF THE CONTRACT DOCUMENTS. THIS DOES NOT INCLUDE WORK ALREADY COMPLETED. T. OBTAIN EXACT LOCATION OF CONNECTION TO EQUIPMENT, FURNISHED BY OTHERS, FROM THE PERSON FURNISHING THE EQUIPMENT. U. DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY AND WHAT IS CALLED FOR IN EITHER ONE IS AS BINDING AS IF CALLED FOR IN BOTH. V. INCLUDE THE BETTER QUALITY, GREATER QUANTITY OR HIGHER COST FOR AN ITEM OR ARRANGEMENT WHERE A DISAGREEMENT EXISTS IN THE DRAWINGS AND SPECIFICATIONS. W. GUARANTEE AND MAINTAIN THE STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION FOR THE PERIOD OF ONE (1) YEAR AFTER THE FINAL COMPLETION OF THE WORK AS EVIDENCED BY ISSUANCE OF THE FINAL CERTIFICATE BY THE ARCHITECT. X. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT HIS OWN EXPENSE TO THE ENTIRE SATISFACTION OF THE TENANT AND ARCHITECT AND ENGINEER. INCLUDE DAMAGE TO THE FINISH OR THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS. Y. REPLACE ALL RECEPTACLES, SWITCHES, COVERPLATES, ETC., DAMAGED BY ANY CONTRACTOR DURING THE COURSE OF CONSTRUCTION. Z. MATERIALS FURNISHED FOR THE TEMPORARY LIGHT AND POWER SYSTEM REMAIN CONTRACTORS PROPERTY. REMOVE WHEN THERE IS NO LONGER ANY NEED FOR TEMPORARY LIGHT AND POWER OR WHEN DIRECTED BY THE ARCHITECT.. AA COORDINATE/SCHEDULE ALL WORK WITH THE TENANT TO MINIMIZE ANY DISRUPTIONS. CONFINE ALL INTERRUPTIONS TO THE SMALLEST POSSIBLE AREA. PROVIDE TEMPORARY CONNECTIONS IF REQUIRED TO PROVIDE CONTINUITY OF SERVICE. BB. INSPECT ALL AREAS AFFECTED BY THE INTERRUPTIONS AND RETURN ALL AUTOMATICALLY CONTROLLED EQUIPMENT, ELECTRICALLY OPERATED EQUIPMENT TO THE SAME OPERATING CONDITION PRIOR TO THE INTERRUPTION. CC. NO FIRE ALARM SYSTEMS ARE TO REMAIN INACTIVE AT THE END OF THE WORK DAY. ASSURE THAT THE FIRE ALARM SYSTEM IS OPERATIONAL AT THE END OF EACH WORK DAY. COORDINATE WITH THE LANDLORD. DD. DO NOT DISTURB NORMAL USE OF THE FACILITY, EXCEPT WITHIN THE IMMEDIATE CONSTRUCTION AREA. KEEP WALKS, DRIVEWAYS, ENTRANCES, ETC. FREE AND CLEAR OF EQUIPMENT, MATERIAL AND DEBRIS. EE. STORE ALL EQUIPMENT AND MATERIAL IN A PLACE AND MANNER THAT MINIMIZES CONGESTION AND IS APPROVED BY THE TENANT. FF. PROVIDE NEW MATERIAL AND EQUIPMENT, UNLESS NOTED OTHERWISE. PROTECT EQUIPMENT AND MATERIAL FROM DAMAGE, DIRT AND THE WEATHER. GG. PROVIDE THE HIGHEST QUALITY WORKMANSHIP AND PERFORM ALL WORK ONLY BY SKILLED MECHANICS. INSTALL MATERIAL AND EQUIPMENT IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS, INSTRUCTIONS AND CURRENT NECA STANDARDS. HH. THE TENANT RESERVES THE RIGHT TO REJECT MATERIAL OR WORKMANSHIP NOT IN ACCORDANCE WITH THE SPECIFICATIONS, BEFORE OR AFTER INSTALLATION. MM. PERFORM ALL CUTTING AND PATCHING NECESSARY TO WORK, UNLESS SPECIFICALLY DELEGATED TO THE GENERAL CONTRACTOR. OBTAIN SPECIAL PERMISSION FROM THE LANDLORD BEFORE CUTTING STRUCTURAL MEMBERS OR FINISHED MATERIAL. PERFORM ALL PATCHING IN SUCH A MANNER AS TO LEAVE NO VISIBLE TRACE AND RETURN THE AREA AFFECTED TO THE CONDITION OF UNDISTURBED WORK. PERFORM ALL PATCHING BY WORKERS EXPERIENCED, SKILLED, AND LICENSED FOR THE PARTICULAR TYPE OF WORK INVOLVED. INFERIOR WORK WILL NOT BE ACCEPTED. NN. PATCH ALL HOLES LEFT AS A RESULT OF DEMOLITION OF ELECTRICAL EQUIPMENT AND DEVICES. 00. PREVENT THE SPREAD OF DUST, DEBRIS, AND OTHER MATERIAL INTO ADJACENT AREAS. PP. REPLACE ALL CEILING TILES DAMAGED DURING INSTALLATION OF WORK, WITH NEW TILE. QQ. PROVIDE MINIMUM 4" HIGH CONCRETE PADS FOR ALL FLOOR MOUNTED EQUIPMENT. RR. SIZE PAD TO PROVIDE A MINIMUM 2" OVERLAP AROUND PERIMETER OF EQUIPMENT. SS. REFINISH ALL ELECTRICAL EQUIPMENT DAMAGED DURING SHIPPING AND /OR INSTALLATION TO ITS ORIGINAL CONDITION. REMOVE ALL RUST; PRIME, AND PAINT PER MANUFACTURER'S RECOMMENDATIONS FOR FINISH EQUAL TO ORIGINAL. TT. PAINT ALL NEW RACEWAY SYSTEMS IN EXPOSED FINISHED AREAS . UU. AFTER TESTS HAVE BEEN MADE AND ACCEPTED, CLEAN LIGHT FIXTURES, PANELS AND OTHER EQUIPMENT INSTALLED BY THE CONTRACTOR, LEAVING THE ENTIRE WORK AREA IN A CLEAN AND COMPLETE WORKING ORDER. W. OPERATE EQUIPMENT AND SYSTEMS IN ALL THEIR OPERATING MODES, TO VERIFY PROPER OPERATION, PRIOR TO FINAL INSPECTION AND OWNER INSTRUCTIONS. NOTIFY THE ENGINEER, IN WRITING, THAT ALL SYSTEMS HAVE BEEN TESTED AND ARE FUNCTIONING AND OPERATING PROPERLY WW. INCLUDE DOCUMENTATION OF INSTRUCTIONS IN THE OPERATION AND MAINTENANCE MANUALS. XX. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ELECTRICAL EQUIPMENT OR MATERIALS UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. KEEP ALL EQUIPMENT CLEAN MATERIALS UNTIL FINAL ACCEPTANCE OF THE ENTIRE PROJECT BY THE TENANT. 16025 - DEMOLITION A EXAMINE THE BUILDING TO DETERMINE ACTUAL CONDITIONS AND EXTENT OF WORK PRIOR TO BIDDING THE PROJECT. REFER ANY UNCLEAR DETAILS OR CONFLICTS TO THE ARCHITECT/ENGINEER FOR CLARIFICATION PRIOR TO BIDDING THE DRAWINGS. B. VERIFY THAT FIELD MEASUREMENTS AND CIRCUITING ARRANGEMENTS ARE AS SHOWN ON DRAWINGS. C. VERIFY THAT ABANDONED WIRING AND EQUIPMENT SERVE ONLY ABANDONED FACILITIES. D. BEGINNING OF DEMOLITION MEANS INSTALLER ACCEPTS EXISTING CONDITIONS. E. COORDINATE PHASING OF THE DEMOLITION WORK WITH THE CONSTRUCTION SEQUENCE SCHEDULE. F. DISCONNECT ELECTRICAL SYSTEMS IN WALLS, FLOORS, AND CEILINGS SCHEDULED FOR REMOVAL. G. COORDINATE UTILITY SERVICE OUTAGES WITH LANDLORD. H. IDENTIFY EXISTING ELECTRICAL EQUIPMENT SUCH AS CONDUITS, BOXES, PULLBOXES, CONDUIT BODIES, AND CONDUIT RACKS THAT WILL NEED ADDITIONAL SUPPORT DUE TO THE DEMOLITION OF THE EXISTING SUPPORTS. I. PROVIDE TEMPORARY WIRING AND CONNECTIONS TO MAINTAIN EXISTING SYSTEMS, INCLUDING TELEPHONE AND DATA SYSTEMS, IN SERVICE DURING CONSTRUCTION. WHEN WORK MUST BE PERFORMED ON ENERGIZED EQUIPMENT OR CIRCUITS, USE PERSONNEL EXPERIENCED IN SUCH OPERATIONS. J. EXISTING ELECTRICAL SERVICE: MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS COMPLETE AND READY FOR SERVICE. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM TENANT, ARCHITECT/ENGINEER AT LEAST 24 HOURS BEFORE PARTIALLY OR DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA K. EXISTING FIRE ALARM SYSTEM: MAINTAIN EXISTING SYSTEM IN SERVICE UNTIL NEW SYSTEM IS ACCEPTED. DISABLE SYSTEM ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM LANDLORD, ARCHITECT/ENGINEER AND LOCAL FIRE SERVICE AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREA ADJACENT TO WORK AREA L. EXISTING TELEPHONE/DATA SYSTEM: MAINTAIN EXISTING SYSTEMS IN SERVICE UNTIL NEW SYSTEMS ARE COMPLETE AND READY FOR SERVICE AND ACCEPTED. DISABLE SYSTEMS ONLY TO MAKE SWITCHOVERS AND CONNECTIONS. NOTIFY AND OBTAIN PERMISSION FROM LANDLORD, ARCHITECT /ENGINEER AND TELEPHONE UTILITY COMPANY AT LEAST 24 HOURS BEFORE PARTIALLY OR COMPLETELY DISABLING SYSTEM. MINIMIZE OUTAGE DURATION. MAKE TEMPORARY CONNECTIONS TO MAINTAIN SERVICE IN AREAS ADJACENT TO WORK AREA M. DEMOLISH AND EXTEND EXISTING ELECTRICAL WORK UNDER AND THIS SECTION, AND AS INDICATED ON THE DRAWINGS. REMOVE, RELOCATE, AND EXTEND EXISTING INSTALLATIONS TO ACCOMMODATE NEW CONSTRUCTION. N. PROVIDE SUPPORTS FOR ALL EXISTING ELECTRICAL EQUIPMENT THAT WAS SUPPORTED PREVIOUSLY BY DEMOLISHED WALLS, FLOORS, CEILING OR OTHER STRUCTURES. PROVIDE NEW SUPPORTS FROM STRUCTURAL MEMBERS NOT SLATED FOR DEMOLITION, PRIOR TO ANY DEMOLITION. 0. TENANT RESERVES THE RIGHT OF FIRST REFUSAL TO OBTAIN MATERIAL SHOWN TO BE REMOVED UNDER THIS CONTRACT. ITEMS NOT RETAINED BY THE TENANT BECOME THE PROPERTY OF THE CONTRACTOR AND MUST BE REMOVED FROM THE PREMISES. P. DEMOLISH AND REMOVE ALL ELECTRICAL SYSTEMS INDICATED FOR DEMOLITION. NO PORTION OF THESE SY STEMS MAY BE ABANDONED IN PLACE. Q. REMOVE ABANDONED WRING TO SOURCE OF SUPPLY. R. REMOVE EXPOSED ABANDONED CONDUIT, INCLUDING ABANDONED CONDUIT ABOVE A CCESSIBLE CEILING FINISHES. CUT CONDUIT IN WALLS, FLOORS, OR COLUMNS BACK TO A POINT WHERE PATCHING CAN BE ADEQUATELY PERFORMED AND PATCH SURFACES. U S. DISCONNECT ABANDONED OUTLETS AND REMOVE DEVICES. REMOVE ABANDONED OUTLETS IF CONDUIT SERVICING THEM IS ABANDONED AND REMOVED. PROVIDE BLANK COVER FOR ABANDONED OUTLETS, WHICH ARE NOT REMOVED. T. DISCONNECT AND REMOVE ABANDONED PANELBOARDS AND DISTRIBUTION EQUIPMENT. U. DISCONNECT AND REMOVE ELECTRICAL DEVICES AND EQUIPMENT SERVING UTILIZATION EQUIPMENT THAT HAS BEEN REMOVED. V. DISCONNECT AND REMOVE ABANDONED LUMINARIES. REMOVE BRACKETS, STEMS, HANGERS, AND OTHER E ACCESSORIES. W. REPAIR ADJACENT CONSTRUCTION AND FINISHES DAMAGED DURING DEMOLITION AND EXTENSION WORK. X. MAINTAIN ACCESS TO EXISTING ELECTRICAL INSTALLATIONS, WHICH REMAIN ACTIVE. MODIFY INSTALLATION OR PROVIDE ACCESS PANEL AS APPROPRIATE. Y. EXTEND EXISTING INSTALLATIONS USING MATERIALS AND METHODS COMPATIBLE WITH EXISTING ELECTRICAL INSTALLATIONS, OR AS SPECIFIED. RELOCATE AND REROUTE CONDUIT AND WIRING AS REQUIRED FOR CONDUIT CONCEALED IN WALLS OR STRUCTURE BEING ALTERED AS PART OF THE REMODELING. MAINTAIN CONTINUITY TO ALL DEVICES IN AND DOWNSTREAM OF REMODELED WORK. Z. REROUTE EXISTING RACEWAY AND WIRING, WHICH IS EXPOSED DUE TO REMOVAL OF EXISTING CONSTRUCTION. CONCEAL NEW RACEWAY AND WIRING AND MAINTAIN OPERATION. M. IF CONDUCTORS ARE REQUIRED TO BE REMOVED FROM EXISTING RACEWAYS, INSTALL WITH NEW CONDUCTORS. BB. PROVIDE NEW COVERPLATES THROUGHOUT THE REMODELED AREAS. CC. DISPOSE OF FLUORESCENT LAMPS, BALLASTS, AND OTHER HAZARDOUS MATERIALS IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS. DD. PRIOR TO REINSTALLATION OF USED EQUIPMENT, THOROUGHLY INSPECT EACH ITEM AND REPORT ANY DEFECTS TO THE ENGINEER/ARCHITECT IN WRITING. INSTRUCTIONS FOR CORRECTIVE MEASURES WILL BE GIVEN AT THE TIME AND THE CONTRACT AMOUNT ADJUSTED ACCORDINGLY. IF NO DEFECTS ARE REPORTED, THE MATERIAL WILL BE INCLUDED UNDER THE CONTRACTORS ONE - YEAR GUARANTEE AS OUTLINED IN SECTION 16010. EE. PANELBOARDS: CLEAN EXPOSED SURFACES AND CHECK TIGHTNESS OF ELECTRICAL CONNECTIONS. REPLACE DAMAGED CIRCUIT BREAKERS AND PROVIDE CLOSURE PLATES FOR VACANT POSITIONS. PROVIDE TYPED CIRCUIT DIRECTORY SHOWING REVISED CIRCUITING ARRANGEMENT. FF. LUMINARIES: REMOVE EXISTING LUMINARIES FOR CLEANING. USE MILD DETERGENT TO CLEAN ALL EXTERIOR AND INTERIOR SURFACES; RINSE WITH CLEAN WATER AND WIPE DRY. REPLACE LAMPS, BALLASTS, AND BROKEN ELECTRICAL PARTS. GG. INSTALL RELOCATED MATERIALS AND EQUIPMENT AS INDICATED ON THE DRAWINGS. 16050 - BASIC MATERIALS AND METHODS A ENCASE ALL CONDUCTORS IN A CONTINUOUS RACEWAY SYSTEM. PROVIDE PULL AND JUNCTION BOXES AS REQUIRED BY THE NEC. SIZE ALL RACEWAY PER THE NEC WITH OVERSIZE CONDUITS AS INDICATED. PROVIDE MINIMUM 3/4" CONDUIT FOR BRANCH CIRCUIT HOMERUNS, PROVIDE MINIMUM 1/2" CONDUIT, UNLESS, NOTED OTHERWISE. B. PROVIDE EMT FOR ALL CONDUCTORS UNLESS NOTED OTHERWISE. PROVIDE CONCRETE -TIGHT STEEL COMPRESSION OR STEEL SETSCREW TYPE FITTINGS, COUPLINGS AND BUSHINGS. CAST OR INDENTOR TYPE DEVICES ARE NOT ACCEPTABLE. ALL FITTINGS USED IN PLENUM APPLICATIONS SHALL BE RATED FOR SUCH USE. C. PROVIDE IMC OR CONCRETE- ENCASED PVC CONDUIT FOR SERVICE ENTRANCE CONDUCTORS. D. PVC CONDUIT MAY BE USED UNDERGROUND OR BELOW CONCRETE SLABS. PROVIDE COATED RIGID STEEL ELBOWS FOR ALL ELBOWS WHERE PVC IS USED. E. PROVIDE FLEXIBLE METAL CONDUIT FOR CONNECTIONS TO TRANSFORMERS, MOTORS AND OTHER VIBRATING PIECES OF EQUIPMENT. PROVIDE LIQUID -TIGHT CONDUIT FOR ALL CONNECTIONS IN DAMP OR WET LOCATIONS. PROVIDE GROUND TYPE FITTINGS AND GROUNDING CONDUCTOR INSIDE ALL FLEXIBLE CONDUIT. ADJUST CONDUIT SIZE IF REQUIRED. F. PROVIDE RECESSED OUTLET BOXES AND JUNCTION BOXES IN ALL NEW CONSTRUCTION. CONCEAL ALL CONDUIT WORK IN NEW CONSTRUCTION, EXCEPT MECHANICAL ROOMS. CONDUIT AND BOXES IN MECHANICAL ROOMS MAY BE RUN EXPOSED. G. PROVIDE EXPANSION FITTINGS WHERE RACEWAY CROSSES BUILDING EXPANSION JOINTS. H. RUN ALL EXPOSED CONDUIT IN A NEAT, WORKMANLIKE MANNER PARALLEL TO THE BUILDING LINES, TIGHT TO THE WALL AND CEILING SURFACES, AND FIRMLY SUPPORT WITH CONDUIT CLAMPS OR HANGERS. PROVIDE TWO (2) HOLE MOUNTING STRAPS, MINIMUM THREE (3) FEET ON CENTER, FOR ALL SURFACE CONDUIT MOUNTED ON WALLS LESS THAN SIX (6) FEET ABOVE FINISHED FLOOR. PLACE CONDUITS AT LEAST 8" AWAY FROM ALL HOT PIPING AND SURFACES INCLUDING DOMESTIC HOT WATER LINES. I. PROVIDE GALVANIZED CODE GAUGE STEEL JUNCTION AND PULL BOXES WITH SCREW ON COVERS OF TYPE, SHAPE AND SIZE REQUIRED TO SUIT EACH INSTALLATION. PROVIDE GASKETING IN DAMP AND DUSTY LOCATIONS. PROVIDE CAST BOXES IN WEATHERPROOF, VAPOR TIGHT AND EXPLOSION PROOF ENVIRONMENTS. J. PROVIDE 4" BOXES THROUGHOUT. PROVIDE 3 1/2" DEEP BOXES WHERE INSTALLED IN MASONRY, 2 1/2" MINIMUM ELSEWHERE. PROVIDE SINGLE GANG MUD OR TILE RING FOR SINGLE DEVICES. K. MOUNT OUTLETS BOXES IN EXPOSED MASONRY WALLS WITH THE BOTTOM OF THE BOX ON THE TOP OF THE MORTAR JOINT AND THE VERTICAL LINE OF THE BOX EITHER ON THE MORTAR JOINT OR ON THE CENTER LINE OF THE MASONRY UNIT. PLUMB AND ACCURATELY ALIGN ALL WALL OUTLETS IN ROWS. MOUNT CEILING BOXES SYMMETRICAL WITH WALLS, BEAMS AND/OR TILES. MOUNTING HEIGHTS INDICATED ON THE DRAWINGS ARE FROM THE CENTER OF THE OUTLET BOX TO THE FINISHED FLOOR DIRECTLY BELOW THE OUTLET. EXTERIOR HEIGHTS ARE FROM INSIDE ADJACENT DOOR, OR IF NO DOOR, FROM THE FIRST FLOOR ABOVE GRADE, UNLESS NOTED OTHERWISE. L. COORDINATE THE LOCATION OF ALL OUTLETS WTH ARCHITECTURAL AND MECHANICAL DRAWINGS BEFORE INSTALLATION. COORDINATE ALL DOOR SWINGS IN THE FIELD BEFORE LOCATING SWITCHES. Mfr. Cooper Hubbell P &S Leviton 1-pole 2221 HBL1221 PS2OAC1 1221 -2 1 -pole w/Pilot 2221PL HBL1221PL PS2OAC1- RPL 1221 -2PL 2 -pole 2222 HBL1222 PS2OAC2 1222 -2 3 -way 2223 HBL1223 PS2OAC3 1223 -2 4-way 2224 HBL1224 PS2OAC4 1224 -2 Keyed 1 -pole 2221L HBL1221L PS2OAC1- L 1221 -2L Mom. Contact 1995 HBL1557 1251 1257 M. PROVIDE NEW WIRING DEVICES IN EACH OUTLET INDICATED ON THE DRAWINGS. PROVIDE ALL DEVICES FROM ONE MANUFACTURER. COLOR TO MATCH ADJACENT SURFACE. N. APPROVED TOGGLE SWITCH MANUFACTURERS/MODEL NUMBERS: 0. APPROVED STANDARD RECEPTACLE MANUFACTURERS/MODEL NUMBERS: Manufacturer Cooper Hubbell P &S Leviton Simplex 5361 HBL5361 5361 5361 Duplex 5362 HBL5362 5362A or PT5362A 5362 GFI XGF20 GFR5352A 2094 8899 IG IG5362 IG5362 IG6300 5362- IG TVSS 5362S HBL5360SA 8300SP 7380 Tamper Resistant TR8300 HBL8300SGA TR63H 8300 -SG "PROVIDE THE CORRESPONDING HOSPITAL GRADE DEVICE WHEN THIS DEVICE IS USED. P. PROVIDE NEW COVERPLATES OVER ALL BOXES WITH THE FOLLOWING SPECIFICATIONS: ALL FINISHED AREAS AND UNFINISHED AREAS PROVIDE SMOOTH PLASTIC COVERS, COLOR TO MATCH ADJACENT SURFACE OR AS SELECTED BY THE ARCHITECT. PROVIDE APPROPRIATE COVERS OVER SPECIAL PURPOSE RECEPTACLES. PROVIDE NEW WEATHERPROOF COVERPLATES FOR OUTLETS AND SWITCHES AS INDICATED ON THE DRAWINGS AND FOR ALL EXTERIOR DEVICES. Q. PROVIDE WIRE AND CABLE WITH INSULATION VOLTAGE RATING EQUAL TO OR GREATER THAN THE APPLIED SYSTEM VOLTAGE. PROVIDE SOLID OR STRANDED COPPER CONDUCTORS WITH TYPE THWN, THHN, OR XHHN INSULATION FOR NO. 12 AWG AND NO. 10 AWG CONDUCTORS. PROVIDE STRANDED COPPER CONDUCTORS WITH TYPE THWN, THHN, OR XHHW INSULATION FOR NO.8 AWG AND LARGER CONDUCTORS. PROVIDE MINIMUM NO. 12 AWG CONDUCTOR SIZE, UNLESS NOTED OTHERWISE. USE THE MINIMUM CONDUCTOR SIZE WHEN NO SIZE IS INDICATED. ALL CONDUCTORS TO BE COLOR - CODED A S FOLL OWS 120/2 08 VO LT SYSTEMS - PH ASE A(BLACK), ), PHASE B[RED), RE D ). PHASE E C BLUE 1. NEUTRAL(WHITE). 277/480 V OLT SYSTEMS - P HASE A BROWN ), PHASE B(ORANGE), GE ), PHASE C(YELLOW), M, NEUTRAL(WHITE WITH TRACER OR GRAY). GROUNDING SYSTEM(GREEN). R. PRIOR TO TURNING THE BUILDING OVER TO THE OWNER TURN ON ALL EQUIPMENT IN THE BUILDING INCLUDING LIGHTING AND WITH A MULTIMETER, READ THE CURRENT DRAWN ON EACH HOT LEG OF FEEDER SUPPLYING EACH DISTRIBUTION PANEL. IF THE CURRENT IN ANY ONE LEG VARIES MORE THAN 5% (PLUS OR MINUS) FROM THE ARITHMETIC AVERAGE OF THE CURRENT IN AL L THE HOT LEGS, RECONNECT THE BRANCH CIRCUITS TO OBTAIN A BALANCED LOADING. S. PROVIDE FIRE BARRIERS AROUND CONDUIT, PIPE, TUBING, BUS DUCTS AND CABLES PASSING THROUGH SMOKE AND FIRE RATED FLOORS AND WALLS. PROVIDE CP 25, 303 AND PSS7904 SERIES BY 3M, OR "FLAME- SAFE" SYSTEM BY THOMAS AND BETTS CORP FOR FIRE SEALS. T. MAKE CONNECTIONS TO ALL MOTORS AND EQUIPMENT FURNISHED AND SET IN PLACE BY OTHERS. PROVIDE STARTERS, MANUAL CONTROLS AND AUXILIARY EQUIPMENT WHERE INDICATED IN SCHEDULES AND SPECIFIED HEREIN. PROVIDE ALL DISCONNECT SWITCHES AS INDICATED IN SCHEDULES, SPECIFIED HEREIN AND REQUIRED BY CODE. 16400 - POWER DISTRIBUTION A. RETAIL METERING CENTER. 1. PROVIDE METER SECTIONS CONTAINING METER QUANTITIES AS INDICATED ON THE DRAWINGS. 2. PROVIDE METER BRANCHES RATED 200 AMP MAXIMUM. 3. PROVIDE 3 PHASE, 4 WIRE METERS FOR USE ON 120/208 VOLT AND 277/480 VOLT, 3 PHASE, 4 WIRE SYSTEMS WITH SEVEN (7) JAW METER SOCKETS. METERS FURNISHED BY THE UTILITY COMPANY. 4. MOUNT ALL OF THE ABOVE COMPONENTS AS SHOWN ON THE DRAWINGS IN A UL APPROVED AND LABELED, NEMA CLASS 1 FLOOR MOUNTED STEEL ENCLOSURE. ENCLOSURE TO BE CONSTRUCTED TO FINISHED STEEL CLEANED, PRIMED, AND PAINTED WITH BAKED ENAMEL FINISH PRIOR TO SHIPMENT TO THE JOB SITE. B. PROVIDE FUSES OF THE FOLLOWING TYPES (BUSSMAN USED AS REFERENCE: 1. 600 AMPS AND ABOVE: TIME -DELAY TYPE DESIGNED TO HOLD 500% OF RATED CURRENT FOR A MINIMUM OF 4 SECONDS AND CLEAR 20 TIMES CURRENT IN 0.01 SECONDS OR LESS WITH INTERRUPTING RATINGS OF 200,000 AMPERES RMS SYMMETRICAL AND PEAK LET- THROUGH CURRENT AND ENERGY LET- THROUGH VALUES ESTABLISHED BY U.L. STANDARD FOR CLASS L FUSES. PROVIDE KRP-C FUSES. 2. BELOW 600 AMPS: DUAL - ELEMENT CONSTRUCTION WITH INTERRUPTING RATING OF 200,000 AMPERES RMS SYMMETRICAL AND PEAK LET -THRU CURRENT ESTABLISHED BY U.L. STANDARD FOR CLASS RK -1 FUSES. PROVIDE LPN- RK/LPS -RK. 3. MOTOR CIRCUITS: PROTECT ALL INDIVIDUAL MOTOR CIRCUITS WITH FULL LOAD AMPERE RATING (FLA) OF 480 AMPERES OR LESS WITH DUAL - ELEMENT TIME -DELAY FUSES. PROVIDE LPN- RK/LPS -RK. PROTECT LARGER HORSEPOWER MOTORS WITH TIME -DELAY FUSES. PROVIDE KRP -C FUSES. PROVIDE U.L. CLASS RK1, DUAL - ELEMENT TIME -DELAY FOR ALL OTHER MOTORS,. 4. MOTOR CONTROLLERS: PROTECT NEMA AND IEC STYLE MOTOR CONTROLLERS WITH DUAL - ELEMENT, TIME -DELAY FUSES TO PROVIDE TYPE 2 COORDINATION FOR THE CONTROLLER. PROVIDE LPS-RK FUSES. 5. PROTECT CIRCUIT BREAKER PANELS WITH U.L. CLASS RK1, CLASS L FUSES. PROVIDE LPN -RK, LPS -RK, OR KRP-C FUSES. 6. PROVIDE FUSE SIZES AS INDICATED ON THE DRAWINGS. 7. ACCEPTABLE MANUFACTURERS: BUSSMAN, FERRAZ - SHAWMUT OR LITTELFUSE OR PRE - APPROVED EQUAL. C. PROVIDE LIGHTING AND APPLIANCE PANELBOARD ASSEMBLIES ADHERING TO THE FOLLOWING SPECIFICATIONS: 1. ENCLOSURES CONSTRUCTED OF GALVANIZED SHEET STEEL OF THICKNESS AS REQUIRED BY CODE, WTH ENAMELED STEEL TRIM, DISTRIBUTED BUSING, HINGED STEEL DOORS LATCHES, LOCKS AND ADJUSTABLE TRIM CLAMPS. PROVIDE NEMA 3R ENCLOSURES FOR EXTERIOR LOCATIONS. 2. PROVIDE WELDED METAL FRAME WITH TYPED CIRCUIT DIRECTORY FOR EACH PANEL. 3. COMPLIANT TO THE FOLLOWING STANDARDS: UL 50, UL 67, NEMA PB-1, NFPA 70 AND FED. SPEC W- P -115C , UL 489, NEMAAB -1, FED. SPEC. W- C- 375B/GEN, IEC 157 -1 AND BS 4752. 4. COMPLIANT TO ARTICLE 384 OF THE NEC: "LIGHTING AND APPLIANCE PANELBOARD". MAXIMUM OF 42 POLES PER PANELBOARD ASSEMBLY. 5. PROVIDE PANELBOARDS WITH INTERRUPTING RATINGS AS SHOWN ONTHE PLANS. 6. PROVIDE 240 VOLT AC RATED PANELBOARDS FOR 208 /120 AND 240 VOLT AC SYSTEMS. PROVIDE 480/277 VOLT RATED PANELBOARDS FOR 480/277 VOLT SYSTEMS. 7. PROVIDE TIN - PLATED COPPER BUS BARS OR TIN - PLATED ALUMINUM BUS BARS. 8. PROVIDE PROPER LUGS (75° C. MINIMUM TEMPERATURE RATING) AND GUTTER SPACE FOR CABLE SIZE INDICATED ON THE PLANS. 9. PROVIDE ALL PANELS BY THE SAME MANUFACTURER. 10. PROVIDE SCREW MOUNTED, ENGRAVED NAMPLATES FOR EACH PANELBOARD. 11. PROVIDE MOLDED CASE, NON- ADJUSTABLE, THERMAL - MAGNETIC, QUICK -MAKE, QUICK - BREAK, BOLT -ON TYPE CIRCUIT BREAKERS. REFER TO THE SCHEDULES ON THE PLANS FOR SIZES AND QUANTITIES. 12. PROVIDE MULI -POLE BREAKERS WHERE INDICATED ON THE SCHEDULES. HANDLE TIES ON SINGLE POLE BREAKERS ARE NOT ACCEPTABLE. 13. SERIES RATING OF CIRCUIT BREAKERS IS NOT ALLOWED. 14. ACCEPTABLE MANUFACTURERS: A. 240 VOLT 1.SQUARE D TYPE NQOD OF NF 2.SIEMENS TYPE 51 SERIES 3.CUTLER HAMMER POW -R -LINE 1A SERIES 4.GENERAL ELECTRIC AQ SERIES 5.PRE- APPROVED EQUAL B. 480 VOLT 1.SQUARED D TYPE NF 2.SIEMENS TYPE 52 SERIES 3.CUTLER HAMMER POW -R -LINE 2A SERIES 4.GENERAL ELECTRIC AE SERIES 5.PRE- APPROVED EQUAL D. PROVIDE PANEL IDENTIFICATION LABEL FOR EACH PANEL INCLUDING PANEL NAME, VOLTAGE AND FEEDER. FOR EXAMPLE: "HDP -1 -1, 480/277 V, 30, 4 WIRE, 2 "C - 4 # 4/0 THWN ". E. MOUNT PANELBOARDS AND CABINETS TO BUILDING STRUCTURE OR INTERIOR WALL CONSTRUCTION. MOUNT INDEPENDENT OF CONDUIT AND RACEWAYS ENTERING BOXES. F. MOUNT PANELBOARDS WITH CABINET TOP AT 78" ABOVE FINISHED FLOOR. G. PROVIDE 3/4 "EMPTY CONDUITS FROM EACH FLUSH MOUNTED PANELBOARD. WHEN THE FLOOR IS ON GRADE, PROVIDE THREE (3) CONDUITS INTO THE CEILING CAVITY ABOVE. WHEN THE FLOOR HAS ACCESSIBLE SPACE BELOW, PROVIDE TWO (2) CONDUITS INTO THE CEILING SPACE ABOVE AND TWO (2) CONDUITS INTO THE ACCESSIBLE SPACE BELOW THE FLOOR. ENDS SHALL BE CAPPED AND SHALL BE TAGGED AT BOTH ENDS WTH PERMANENT TAGS. H. PROVIDE A CIRCUIT DIRECTORY COMPLETELY TYPED ON THE INTERIOR OF EACH PANEL DOOR. I. EQUIPMENT GROUND - SOLIDLY GROUND ALL CONDUIT SYSTEMS, SWITCH BOXES, CABINETS, MOTOR FRAMES, SWITCHGEAR, TRANSFORMERS, AND ALL OTHER PERMANENTLY INSTALLED EQUIPMENT IN ACCORDANCE WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE TO FORM A CONTINUOUS, PERMANENT AND EFFECTIVE GROUNDING SYSTEM. BOND EXPANSION JOINTS AND METAL RACEWAY SECTIONS. PROVIDE GROUND CONDUCTOR AS INDICATED ON THE DRAWINGS OR SPECIFIED HEREIN. J. WHEN CONNECTING SINGLE PHASE CIRCUITS AND EQUIPMENT TO A THREE (3) PHASE SYSTEM, DISTRIBUTE THE LOADS ON THE PHASES TO ACHIEVE AN APPROXIMATELY BALANCED LOADING OF THE THREE -PHASE SYSTEM. 16430 - MOTOR CONTROL A PROVIDE "ON -OFF' TOGGLE TYPE MANUAL STARTER SWITCH WITH THERMAL OVERLOAD PROTECTION FOR SINGLE PHASE MOTORS, WHERE MANUAL CONTROL IS INDICATED. PROVIDE EACH SWITCH WITH A RED PILOT LIGHT INDICATING WHEN MOTOR IS ON. B. PROVIDE FULL VOLTAGE TYPE STARTERS AND THERMAL OVERLOAD PROTECTION AND EXTERNAL MANUAL RESET FOR ALL THREE -PHASE MOTORS, UNLESS INDICATED OTHERWISE. EQUIP EACH STARTER WITH 120 VOLT COIL, CONTROL POWER TRANSFORMER, SECONDARY FUSE BLOCK AND FUSES, AUXILIARY CONTACTS AS INDICATED, RED "ON" PILOT LIGHT, AND "HAND -OFF -AUTO" CONTROL SWITCH. PROVIDE COMBINATION STARTER/DISCONNECT WHEN INDICATED ON THE PLANS. ACCEPTABLE MANUFACTURERS FOR MAGNETIC STARTERS: ALLEN- BRADLEY BULL. 509 &512, SQUARE D CLASS 8536, CUTLER HAMMER, GENERAL ELECTRIC, ITE/SIEMENS EQUIVALENT OR PRE - APPROVED EQUAL. C. PROVIDE MANUAL MOTOR STARTING SWITCH OR TYPE "SS" FUSED DISCONNECT ADJACENT TO EACH 120 VAC SINGLE PHASE MOTOR LOCATED OUT OF SIGHT AND /OR IN EXCESS OF 50' -0" FROM THE CONTROLLER, OR AS INDICATED ON THE DRAWNGS.. D. INTER LOCK ROOFTOP HVAC UNIT FAN STARTER WITH DUCT DETECTOR TO SHUT DOWN FAN UPON DETECTOR ACTIVATION. 16460 - TRANSFORMERS A. PROVIDE VENTILATED, INDOOR, DRY -TYPE DISTRIBUTION TRANSFORMER WITH THE CAPACITY AND VOLTAGE CHARACTERISTICS INDICATED ON THE DRAWNGS. TRANSFORMERS 15 KVA AND ABOVE WILL BE DESIGNED TO OPERATE WITH A 115 DEGREES C. TEMPERATURE RISE ABOVE 40 DEGREES C. AMBIENT. PROVIDE ALL INSULATING MATERIALS FOR A 220 DEGREES C. INSULATION SYSTEM. B. PROVIDE TRANSFORMERS MEETING OR EXCEEDING NEMA CLASS 1 EFFICIENCY REQUIREMENTS AS REQUIRED IN THE LOCAL ENERGY CODE. C. PROVIDE VOLTAGE TAPS AS INDICATED BELOW: 1. PROVIDE TWO 5% FCBN TAPS FOR ALL SINGLE AND 3 PHASE TRANSFORMERS 9 KVA AND BELOW. 2. PROVIDE TWO 21/2 /o FCBN AND ND TWO 2 1/2% FCAN TAPS FOR ALL 3 PHASE TRANSFORMERS 15 KVA AND BELOW. 3. PROVIDE FOUR 2 1/2% FCBN AND TWO 2 1/2% FCAN TAPS FOR ALL 3 PHASE TRANSFORMERS ABOVE 15 KVA D. PROVIDE SOUND RATINGS NOT EXCEEDING THE FOLLOWING LEVELS: 1. 0 TO 15 KVA, 40 DECIBELS. 2. 15 TO 50 KVA, 45 DECIBELS. 3. 50 TO 150 KVA, 50 DECIBELS. 4. 150 KVA OR GREATER, 50 DECIBELS. E. U ORS WITH BRAZED OR WELDED 0 CONDUCTORS CONTINUOUS COPPER OR ALUMINUM COIL COND TERMINATIONS. F. ISOLATE TRANSFORMER CORE AND COIL FROM THE ENCLOSURE USING VIBRATION - ABSORBING MOUNTS. G. PROVIDE TRANSFORMERS 75 KVA OR LESS WITH ENCLOSURES SUITABLE FOR WALL, FLOOR OR TRAPEZE MOUNTING. PROVIDE TRANSFORMER LARGER THAN 75 KVA WITH ENCLOSURES SUITABLE FOR FLOOR OR TRA PEZE MOUNTING. H. PROVIDE MAXIMUM CASE TEMPERATURES NOT EXCEEDING A 35C TEMPERATURE RISE ABOVE A 40 DEGREE C AMBIENT. I. ACCEPTABLE MANUFACTURERS: CUTLER HAMMER, GENERAL ELECTRIC, SORGEL, HEVI -DUTY JEFFERSON ELECTRIC OR PRE - APPROVED EQUAL. 16500 - LIGHTING A COMPLY WITH NEC AS APPLICABLE TO THE INSTALLATION AND CONSTRUCTION OF LIGHT FIXTURES. B. COMPLY WITH UBC AS APPLICABLE TO THE INSTALLATION AND CONSTRUCTION OF LIGHT FIXTURES. C. PROVIDE LIGHT FIXTURES THAT ARE LISTED AND LABELED BY U.L. OR ANOTHER NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE APPLICATION. D. PROVIDE LAMP BALLASTS THAT COMPLY WITH CERTIFIED BALLAST MANUFACTURERS ASSOCIATION STANDARDS AND CARRY THE CBM LABEL. E. COMPLY WITH ALL LOCAL, STATE AND FEDERAL ENERGY CODES. F. PROVIDE FIXTURES WITH LAMPS, FOR EACH OUTLET SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREIN. SEE FIXTURES LIST ON THE PLAN. G. PROVIDE FLUORESCENT LAMP BALLASTS WITH THE FOLLOWING MINIMUM SPECIFICATIONS 1. DISCONNECTING MEANS ON THE LINE SIDE OF THE BALLAST TO DISCONNECT ALL HOT AND NEUTRAL CONDUCTORS, AS REQUIRED AFTER JANUARY 1, 2008 BY THE 2005 NEC ARTICLE 410.730. PROVIDE EITHER FACTORY - INSTALLED DISCONNECTING MEANS, OR PROVIDE FIELD - INSTALLED DISCONNECT INSIDE THE BALLAST CHANNEL a. APPROVED FIELD - INSTALLED DISCONNECT 1) WAGO 873 2) TYCO /AMP LIGHT -N -LOK CPGI SERIES 3) T & B STA -KON LD2/LD3 SERIES 2. PROVIDE U.L. LISTED AND LABELED, C.B.M. APPROVED BALLASTS. 3. PROGRAMMED RAPID START TECHNOLOGY TO ENSURE LONGEST LAMP LIFE. 4. T8 ONLY: PARALLEL -WIRED OPERATION TO ENSURE LIGHT OUTPUT FROM ONE BALLAST EVEN WTH ONE OR TWO LAMPS EXTINGUISHED. 5. COMPACT FLUORESCENT ONLY: SERIES WIRED LAMPS FOR MULTIPLE LAMP CONFIGURATIONS, AND PLUG -IN LEAD CONNECTORS FOR ALL LAMP LEADS 6. CLASS "P" RATED WITH THERMALLY ACTIVATED AUTOMATIC RESETTING PROTECTIVE DEVICES SEALED IN HOUSING. 7. CURRENT CREST FACTOR: 1.7 OR LESS ON 60 HZ MODULATED CURRENT. 8. COMPLY WITH FCC RULES PART 18 REQUIREMENTS GOVERNING ELECTROMAGNETIC AND RADIO FREQUENCY INTERFERENCE 9. COMPLIES WITH IEEE 587 FOR WITHSTANDING LINE TRANSIENTS, VOLTAGE REGULATION ± 10 PERCENT, LIGHT REGULATION + 10 PERCENT. 10. BALLAST FACTOR: 0.88 OR HIGHER. 11. POWER FACTOR: GREATER THAN 95 PERCENT 12. SOUND RATING: "A" 13. MINIMUM 5 YEAR WARRANTY INCLUDING $10/BALLAST LABOR 14. TOTAL HARMONIC DISTORTION: <20 %, BUT GREATER THAN 10% 15. END -OF -LIFE LAMP SENSING FOR ALL COMPACT FLUORESCENT BALLASTS. H. APPROVED MANUFACTURERS - T8 ELECTRONIC BALLASTS 1. ADVANCE CENTIUM PROGRAM RAPID START SERIES 2. UNIVERSAL LIGHTING TECHNOLOGIES TRIAD ACCUSTART SERIES I. APPROVED MANUFACTURERS - COMPACT FLUORESCENT 1. MOTOROLA GOLD EDITION 2. ROBERTSON 3. OSRAM QUICKTRONIC SERIES 4. UNIVERSAL LIGHTING TECHNOLOGIES J. PROVIDE INSIDE FROSTED LAMPS WITH BRASS BASE, RATED 130 VOLTS FOR ALL INCANDESCENT LAMPS, UNLESS NOTED OTHERWISE. 1. APPROVED MANUFACTURERS A. PHILIPS B. GENERAL ELECTRIC C. OSRAM/SYLVANIA D. PRE - APPROVED EQUAL K. PROVIDE MINIMUM 85 CRI FOR ALL FLUORESCENT LAMPS. PROVIDE 4100K COLOR LAMPS FOR ALL FLUORESCENT FIXTURES. 1. PROVIDE F032, F025 AND F017 T8 LAMPS FOR ALL 4', 3' AND 2' FIXTURES, RESPECTIVELY, UNLESS NOTED OTHERWISE. 2. APPROVED MANUFACTURERS: A. GE STARCOAT SPX B. PHILLIPSTL80 C. OSRAM SYLVANIA OCTRON 800XP L. PROVIDE SOLID STATE, SLID -TYPE DIMMERS SUITABLE FOR MOUNTING BEHIND A STANDARD DEPTH FACEPLATE AND FOR OPERATION ON COMMON NEUTRAL CIRCUITS. 1. PROVIDE 600 WATTS CAPACITY PER DIMMER UNLESS NOTED OTHERWISE ON THE PLANS. 2. ACCEPTABLE MANUFACTURERS: LUTRON NOVA T -STAR SERIES OR PRE - APPROVED EQUAL. M. SOLID STATE TYPE TIME SWITCHES. 1. PROVIDE SOLID STATE, PROGRAMMABLE 24 HOUR OR 7 -DAY, ELECTRIC TIME SWITCH WITH FOUR (4) SPST CONTACT RATED 20A AT 240 VOLTS. PROVIDE LONG LIFE LITHIUM BATTERY BACKUP TO MAINTAIN TIME AND MEMORY SETTING DURING A POWER OUTAGE. 2. PROVIDE ASTRONOMICAL CONTROL. 3. ACCEPTABLE MANUFACTURERS A. PARAGON EC7000 SERIES B. TORK MODEL D100 SERIES C. PRE- APPROVED EQUAL N. PROVIDE LIGHTING CONTACTORS THAT ADHERE TO THE FOLLOWING SPECIFICATIONS, WHERE LIGHTING CONTROL RELAYS OR CONTACTORS ARE CALLED OUT ON THE DRAWINGS: 1. ELECTRICALLY HELD RELAY, 30 AMP BALLAST RATED, 20 AMPS TUNGSTEN RATED @ 277 VOLTS 2. 2 POLE MINIMUM (REFER TO PLANS FOR REQUIRED POLES) 3. INSTALLED IN NEMA 1 ENCLOSURE INDOORS, NEMA 3R ENCLOSURE OUTDOORS. 4. COIL VOLTAGE: 24VAC. 5. COORDINATE ACCESSORIES WITH DIVISION 15'S EMS CONTRACTOR. 6. APPROVED MANUFACTURERS: A. SQUARE D CLASS 8903, TYPE SERIES B. ASCO917SERIES C. SIEMENS TYPE CLM D. PRE - APPROVED EQUAL 0. PROVIDE PHOTOELECTRIC SWITCH CONTROL WITH A SET OF SPST CONTACTS RATED AT 120 VOLT AC, 1800VA IN A NEMA 3R ENCLOSURE. 1. UL LISTED. 2. APPROVED MANUFACTURERS: A. PARAGON CW/210 SERIES B. TORK 2101 SERIES 3. IF USED AS A SENSOR INPUT TO THE LIGHTING CONTROL SYSTEM, PROVIDE PHOTOCELL CONTROLLERS FULLY - COMPATIBLE WITH THE LIGHTING CONTROL PANELS USED ON THIS PROJECT. REFER TO SECTION 16915. P. PROVIDE ALL HANGERS, RODS, MOUNTING BRACKETS, SUPPORTS, FRAMES, ETC. FOR PROPER AND SAFE FIXTURE INSTALLATION. INSTALL ALL FIXTURES IN ACCORDANCE WITH MANUFACTURERS' RECOMMENDATIONS AND INSTRUCTIONS. Q. PROVIDE FIXTURES COMPLETE WITH ALL AUXILIARIES REQUIRED FOR PROPER, SAFE AND DISTORTION FREE INSTALLATION IN THE VARIOUS CEILING CONSTRUCTIONS IN WHICH THEY APPEAR. COORDINATE CEILING TYPES WITH THE ARCHITECTURAL DRAWINGS AND PROVIDE COMPATIBLE FIXTURES. R. PROVIDE FELT OR FIBERGLASS GASKETS ON ALL INCANDESCENT LIGHTING FIXTURES WHERE NECESSARY TO PREVENT LIGHT LEAKAGE AT THE CEILING LINE. S. SECURELY SUPPORT ALL LIGHT FIXTURES DIRECTLY FROM BUILDING STRUCTURAL MEMBERS OR 11/2" OR LARGER STEEL CEILING FRAMING CHANNELS. USE STEEL CHANNEL EQUIVALENT TO KINDORF #6029 WHERE IT IS NECESSARY TO SPAN THE BUILDING STRUCTURAL MEMBERS FOR FIXTURE SUPPORT. WOOD SUPPORTING MEMBERS OR WIRES WILL NOT BE ACCEPTABLE. PROVIDE WOOD STRUCTURAL MEMBERS. E LAG SCREWS WHEN ANCHORING G INT 0 W U 4 DIAMETER MINIMUM / PENETRATE WOOD STRUCTURAL MEMBERS A MINIMUM OF 2" WITH ALL SCREWS. PROVIDE STEEL OR LEAD, EXPANDABLE TYPE, ANCHORS WITH MINIMUM PENETRATION OF 11/2" WHEN ANCHORING TO CONCRETE. WHEN INSTALLING LIGHT FIXTURES IN A SEISMIC ZONE, SECURE TO MEET ALL REQUIREMENTS. T. DO NOT SUSPEND ANY CONDUIT, LIGHT FIXTURES, OR BALLASTS FROM METAL ROOF DECK OR FROM THE CEILING SUSPENSION WIRES. SUPPORT ALL LAY -IN FIXTURES INDEPENDENT OF THE CEILING SUPPORT SYSTEM. PROVIDE FASTENING CLIPS ON EACH CORNER OF EACH FIXTURE IN ACCORDANCE WITH THE UBC AND STATE BUILDING CODES. U. EQUIP ALL FIXTURES USING CONDUIT STEMS WITH BALL SWIVEL HANGERS. IN FINISHED AREAS, AN PROVIDE CANOPIES ES FOR THE HANGERS. V. SUPPORT ALL SURFACE MOUNTED FLUORESCENT FIXTURES WITH A MINIMUM OF ONE HANGER PER FIXTURE PLUS ONE PER ROW. SUPPORT INDIVIDUAL FIXTURES WITH A MINIMUM OF TWO HANGERS. ATTACH FIXTURE HANGERS TO THE CEILING GRID PER CODE. W. SUPPORT ALL SUSPENDED FLUORESCENT FIXTURES WITH A MINIMUM OF TWO FIXTURE HANGERS. ATTACH EACH HANGAR TO A DEDICATED ANCHOR. LOCATE HANGARS DIRECTLY ABOVE THE CORNERS OF THE LIGHT FIXTURES. X. WHERE MASTER/SLAVE OR INBOARD /OUTBOARD SWITCHING IS INDICATED, PROVIDE TANDEM -WIRED BALLASTS BETWEEN LIGHT FIXTURES AS REQUIRED BY THE LOCAL ENERGY CODE Y. WIRE ALL RECESSED LAY -IN FIXTURES WITH 6 FEET OF FLEXIBLE METAL CONDUIT WITH TYPE 'THHN/THWN" WIRE TO THE OUTLET BOX. PROVIDE GROUNDING TYPE CONNECTORS FOR ALL CONDUIT AND CABLE. Z. PROVIDE OUTLET BOXES ADJACENT TO EACH RECESSED FIXTURE OUTLET IN SUSPENDED CEILINGS TO PERMIT EACH FIXTURE TO BE ADJUSTED TO FIT CEILING PATTERN AND TO PERMIT "FEED THROUGH" WIRING. AA. AT THE TIME OF SUBSTANTIAL COMPLETION, ALL FIXTURES MUST BE INSTALLED AND LAMPED WITH NEW LAMPS. INSTALL ALL FIXTURES COMPLETE WITH LENSES, DIFFUSERS, REFLECTORS, LOUVERS AND OTHER REQUIRED ACCESSORIES. BB. REPLACE ANY DAMAGED REFLECTORS, DIFFUSERS, LOUVERS OR OTHER COMPONENTS AT NO EXPENSE TO THE OWNER. CC. CLEAN ALL FIXTURES FREE OF DUST, FINGER PRINTS, PAINT, ETC.. DD. PERFORM AIMING AND ADJUSTMENT OF ALL LIGHTING FIXTURES IN ACCORDANCE WITH INSTRUCTIONS ISSUED BY THE ENGINEER/TENANT. ADJUST ALL DIRECTIONAL TYPE FIXTURES (INTERIOR AND EXTERIOR) AFTER DARK UNDER THE DIRECTION OF THE ARCHITECT, ENGINEER, AND /OR TENANT. EE. REPLACE ALL DEFECTIVE BALLASTS WITHIN THE GUARANTEE PERIOD AT NO COST TO THE TENANT. FF. INSTALL DIMMERS WHERE INDICATED ON THE DRAWINGS. 1. WHERE DIMMERS ARE SHOWN GANGED WITH OTHER DIMMERS AND /OR OTHER DEVICES, SIZE OUTLET SUCH THAT DIMMERS WILL NOT BE UNDERATED. GG. INSTALL PHOTOCELL(S) PER MANUFACTURER'S RECOMMENDATIONS. 1. AIM AWAY FROM ARTIFICIAL LIGHT SOURCES SUCH AS STREET LIGHTS OR SECURITY LIGHTS. 2. SEAL PENETRATIONS THROUGH ROOF OR PENTHOUSE WALL. HH. INSTALL TIME SWITCHES ADJACENT TO THE SOURCE LIGHTING PANEL, UNLESS SPECIFICALLY LOCATED ELSEWHERE ON THE PLANS. 1. SET LONGITUDE AND LATITUDE SETTINGS AND THE ASTRONOMICAL TIME. 2. PROVIDE TIME SETTINGS PER THE TENANT'S DIRECTION. MMM.PROVIDE "NAMEPLATES" A SPECIFIED IN SECTION 16050 FOR ALL CONTACTORS AND TIME SWITCHES. LABEL CONTACTORS AND TIME SWITCHES TO INDICATE LOAD SERVED (E.G., CANOPY LIGHTS, STORE SIGN, ETC.). 16535 - EMERGENCY LIGHTING A PROVIDE AUTOMATIC BATTERY POWERED LIGHTING UNITS AS INDICATED ON THE DRAWINGS. B. PROVIDE EMERGENCY LIGHTING AS SHOWN ON THE PLANS TO ILLUMINATE THE EGRESS CORR AND OTHER REQUIRED AREAS. REFER TO THE LIGHT FIXTURE SCHEDULE ON THE DRAWING TYPES. C. PROVIDE AN INTENSITY OF NOT LESS THAN 1.0 FOOTCANDLE AT THE FLOOR LEVEL ALONG THE P OF EGRESS. D. PROVIDE AN EXIT LIGHT AT EACH EXIT AND ALONG THE EGRESS PATH AS REQUIRED. E. CONNECT EMERGENCY LIGHTS TO THE UNSWITCHED BRANCH CIRCUIT(S) IN THE AREA PROVID HANDLE -LOCK DEVICE FOR THAT CIRCUIT. 16741 -.VOICE AND DATA RACEWAY A PROVIDE 4" SQUARE BOXES FOR EACH RECESSED OUTLET BOX. PROVIDE 31/4' DEEP MASONRY TYPE IN RECESSED MASONRY INSTALLATIONS. PROVIDE MUD OR TILE RING AS REQUIRED FOR ALL BOXES. B. PROVIDE THE FOLLOWING IN ACCESSIBLE CEILINGS AS FOLLOWS: PROVIDE AN EMPTY BOX WITH (1) 3/4" CONDUIT STUBBED INTO CEILING SPACE FOR EACH TELEPHONE OUTLET INDICATED ON THE DRAWINGS; PROVIDE AN EMPTY BOX WITH (2) 3/4" CONDUIT STUBBED INTO CEILING SPACE FOR EACH DATA, VOICE/DATA OR FIBER OPTIC OUTLET INDICATED ON THE DRAWINGS. C. PROVIDE THE FOLLOWING IN INACCESSIBLE CEILINGS (PLASTER, SPLINE, GYPSUM, SECURITY GRID, PLANK, ETC.) AS FOLLOWS: PROVIDE AN EMPTY BOX WITH (1) 3/4" CONDUIT ROUTED TO THE NEAREST TELEPHONE BACKBOARD LOCATION FOR EACH TELEPHONE OUTLET, UNLESS NOTED OTHERWISE ON THE PLANS; PROVIDE AN EMPTY BOX WITH (2) 314" CONDUIT ROUTED TO THE NEAREST COMMUNICATIONS CLOSET BACKBOARD LOCATION FOR EACH DATA, VOICE/DATA, OR FIBER OPTIC OUTLET, UNLESS NOTED OTHERWISE ON THE PLANS. DATE: JOB NO: 07/08/08 08- 0196.004 DRAWN: MDR CHECKED: SOR 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635 -5699 Project Coordination By: 10 u w Q J ce a Nor a! ww 1:tHH Www aE-m� 00 N N M M ■D 00 CO cs '".111r,}5 RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER . 44030 H A LLBER ENGINEERING ' s /r3Nr.t.0 0` .a, Mechanical /Electrical conagrigh Engineers -, 1750 Commerce Cou s,- MN- 5514O' - (651) 748 -1100 • Fax (651) 748 -9370 REVISIONS ELECTRICAL SPECIFICATIONS SHEET NUMBER E3