Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-1018 - BANK OF AMERICA
BANK OF AMERICA STRANDER BLVD ELO8-1018 Cityal If Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 320 STRANDER BL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1018 Issue Date: 10/23/2008 Permit Expires On: 04/21/2009 Tenant: Name: BANK OF AMERICA Address: 320 STRANDER BL , TUKWUJA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: BRIAN VAN STIPDONK Phone: 206 654 -2129 Address: 1200 6 AV, STE 500 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: ELECTRICAL FOR NEW STAND ALONE BUILDING: POWER, LIGHTING, FIRE .ALARM, AND SECURITY SYSTEMS. Value of Electrical: 269,353.00 Fees Collected: $4,340.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: (0 - 7.3 -00 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the peformance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: /U 2 3 - oP This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1018 Printed: 10 -23 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 320 STRANDER BL TUKW BANK OF AMERICA PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1018 ISSUED 07/18/2008 10/23/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: e Cr 'Lc✓ Date: / ° 2 3 -cab' doc: Cond -Elec EL08 -1018 Printed: 10 -23 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 S'luthcQnter 1JcL, Suite 100 Tukwile, WA 9613 p./A-r tm . r r. tuk• ':e. wa. u ELECTRICAL PERMIT APPLICATION Applicati ,ns and plats must be complete in order to be accepted for plan rc. :a rt'ications wii; not be accepted through the mail or by fax *Please Print *. u. Address • /t i; Tenant Name: Property Owners Name. Mailing Address : $7t King Co Assessor's Tax No,: Suite Number: Plan: New Tenant: .....Yes, Name: (fit . Ma:l ng Address: E-Mail Address: ELECTRICAL CONTRACTOR 1NFO op Day Telephone: ] C+sy f r■rs CO KV"� Fax ? umher: AT ON Company Name: Mailing Address:.„ Contact Person E -Mail Address: Contractor Registration Number: momilmomow City Day Telephone: Fax Number: Expiration Date: Zip Valuation of Project (contractor's bid price): S ScRpe of War' (please provide detailed information as Will service be altered? 0 yes Type of Use: et i in e I -of w rrk: New 0 Addition 0 Low Voltage 0 Generator ervcd by: uget Sound Energy Seattle City Light It :'•.'APP on.tans ?Fnrca Appliwlrons CT.rUnet4400 ?. Efac. al Tkni4A O Service Change o Fire Marm Adding more than 50 amps? Yo 0 No Q Remodel 0 Tenant Improvement O Telecommunication 0 Temporary Service Page i of 2 NEW RESIDErgw. `' T New single family dweflines 5140.00 (including an attached garages t_.i Gar 3ites, 3t ols, spas and outbuildings;... . ..............$75.00 ea O Low voltage systems (alarm, furnace thcrrrtostat) ...... ... ....... ... ..... SS5.00 ca RESIDENTIAL, RE tORCI, AND SERVICE CHANGES O Service change or alteration ,, ........ $75.00 (no addedialtered circuits) O Service change with added/altered circeatts , „.......575.00' number of added circuits ... $10.00 ea Circuits addedffaicered without service change ........,..550.00 (up to 5 circuits) f Circuits nddedtaltcred without service change ....,.. ... ..550.00 (6 or more circuits).,....:. 57.00 ea j Mcterlmctst repair .. ..,. .. .$65.00 L Low voltage systems .$55.00 (atium, furnace thermostat) PERMIT APPLICATION NOTI MI LTT FAMILY AND COM Fees ue based on the valuation of the clecira.-si cort1ratcc. MISCEI LANF,OT'S FEES O Temporary service (residenuai) ......... 5,18.00 O Temporary service (generator)... ...... ..... ...........,575.00 Q Manufaeluredtmobite home service 580;00 (excluding garage Of vi:tbuilding) O Carnivals ......... 375.00 dumber of concessions .. ,$10.00 ea Value of Construction — In all cases, a value oleo truction amount should be entered by the applicant. This figure will he reviewed a to possible revision by the Pertnit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by Jiruitatacr. Me BBuiiding Official may grant one extension of lime for an additional period not to exceed 90 days, The extension shall be requested in writing and justifcablc cruse demonstrated. 1 IIEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTIIORIZED TO APPLY FOR THIS PERMIT. Bt'ILD1t G QWNER OR ELECTRIC*. CONT:'RACTOa: uhject Signature: Print Nat Mailing Address: ft' Date Applicati Date: ' 1/ 1,a/t C 0 Day Tel hone: i/ +;t/t'� "--- O'l�///pry� ccen Ctrr sty Zp Application Expi I.Urpphc En ons.Fenns- AppiESx uiss f?n. t.ins14.2007 Appiimouli.doc Page 2af2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: htv/Iwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -02643 Initials: JEM User ID: 1165 Payee: GENSLER Payment Date: 07/18/2008 Total Payment: 6,648.25 SET ID: S000001082 SET TRANSACTIONS: Set Member Amount 1EL�'081018 4,340.00 M08 -190 1,726.25 PG08 -210 582.00 TOTAL: 6,648.25 TRANSACTION LIST: Type Method Description SET NAME: Tmp set/Initialized Activities Amount Payment Check 110577 ACCOUNT ITEM LIST: Description TOTAL: 6,648.25 6,648.25 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES 000.322.101.00.0 3,472.00 000.345.832.00.0 868.00 000.322.103.00.0 90.00 000.322.102.00.0 1,381.00 000/345.830 421.25 000.322.103.00.0 416.00 TOTAL: 6,648.25 5.,,'7 0 "/18 ' 716 TOTA! 5648.. : Doc: RECSETS -06 INSPECTION RECORD Retain a copy with permit INS I ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'V--- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Eio� -yak Project: 6 A Type of Inspection: 2100 �' Address: 3244 I r244 Date Called: Special Instructions: Date Wanted: 07 fr 1 p.m. Requester: Phone No: COMMENTS: CoNfator45 nvtot - -mei) PA4z-ri ow) cvm-. c.iptert Inspector: Date: c7 V of h Approved per applicable codes. LJ Corrections required prior to approval. to ins ecti n fee m El $60.00 REINSI'ECTION FEE REQUIRED. Prior p , st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: . s •� - y �,� INSPECTION RECORD 0(48 INSPE I IO Retain a copy with permit 00 N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 \\ Project: j or. A Type of Inspection: 2100 Address: 20 5rain i D ` „ Date Called: Special Instructions: Date Wanted: ke ( I I Q aRequester: Phone No: ElApproved per applicable codes. DCorrections required prior to approval. COMMENTS: - qINoJE aIo2K oepCiit Sco I'f Fob en4i€LP Pwri ritt-P NM- Inspector: Date: 041 s du\ r7 $60.00 REINS to inspection, FEE R OUIRED. Prior fee m t be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: A /6 r.� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 0 6-og-DA Project: Q o., A.. Type of Inspection: ;f00 l ` �J Address: 32-0 ,i.4j. Date Called: - loctLAWs i-U Nsc i4 PouJc1 Milir - 6e4-414-k, (--if, -xip L C.c P Fog ; Special Instructions: Date Wanted: QG 1 1 a P.m. Requester: Phone No: ['Approved per applicable codes. Corrections required prior to approval. f COMMENTS: - - -64> Poi' To CO — CAA 2 w 'k (osArA J - ¢1 {64A4t (kf•9 AiT A Cyr of Ta P LAEt --5 - ()Jf C Ks Is T5 - loctLAWs i-U Nsc i4 PouJc1 Milir - 6e4-414-k, (--if, -xip L C.c P Fog ; spit id ;Clic Pvl P - WC4ri._. FvA . Alcmc FlLC b Tt It r A- PPD./Dvi of wass 1,-Te, . Inspector: 14� � Date: fmc oelrr $60.00 REINSPECTION FEE R WIRED. Prior to inspection, fee Just be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 1 2 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6.01- 10 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 3 oc A Type of Inspection: 7o,5 Address:320 ` Date Called: Special Instructions: Date Wanted: 06 01 a , per Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: • arL'�(1 c0 - Koutia cofizr Date: x101( of ri $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: Receipt No.: Date: 11 INSPECTION.RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 127 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 6a- tog Project: Di /I �{ 6 Type of Inspection: 70°/ Address: 32o 5-„ Date Called: �, Special Instructions: Date Wanted: /� !/ 7 I p.m- Requester: /// Phone No: Approved per applicable codes. Corrections required prior to approval. S` COMMENTS: Pq OK. th4bektleoND Fac P�rhe� ut,wrj Inspector exedrsi fjp Date: to inspection, 05119/01 e m $60.00 REINSPECTION FEE REQUIRED. Prior must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: 10 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit toil- ioi� PERMIT NO. (206)431 -3670 Project: 13_, bi- et Type of Inspection: �00 Address: 3i0 57RAdDfic Date Called: Special Instructions: Date Wanted: D ! ' I 5 cf:e11.Reuester: Phone No: ❑ Approved per applicable codes. Ei Corrections required prior to approval. COMMENTS: P4 Dx co‘iei:\ 1�RiJE -TJ ►� c�,oPy 442D t-iD o�Ly Inspector: craZ6 Date: 05- / /07 $60.00 REINSI'ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Z. INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 fog- io Project: QF Type of Inspection: 7oo2_ PA Address: 320 Sfeck4Def Date Called: OK. - GT (Ad co,rodS /AE Lsot PaJEC.. A Special Instructions: Date Wanted: I� 30 ®I rn: Requester: Phone No: 0 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: PA OK. - GT (Ad co,rodS /AE Lsot PaJEC.. A 61/00AIDIAJCI /6601Alci 14 A OK. - 7-6 EAIEg 016 Inspector: j Date: nil 3b c El $60.00 REINS ECTION FEE R OUIRED. Prior to inspection, fee rnt st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. 14- (206)431 -3670 Project: ba. j Type of Inspection: r]DD , 3 Address: 32-o grupl Date Called: Special Instructions: Date Wanted- �� a.m. p.m. Requester: Phone No: riApproved per applicable codes. ElCorrections required prior to approval. !� COMMENTS: - Epve-f, RcAir c6 4449 up Inspector: 6‘14461\ Date: p J Z1 o ❑ $60.00 REIN PECTION FEE REQUIRED. Prior to inspection, fee m (ist be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: If'` - -x,e.x0[2. em - ME:•eid _ g 1i _°__'- ._dAP(a ti`m.c ' iif •••• • aw-- �di�n},f INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 Ecm -IorB Project: g or A Type of Inspection: 7003 Address: stvicaoest Date Called: Special Instructions: Date Wanted: Cli 04//42.y. Requester: 0i Phone No: LIApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: P4, 0i 4C (A Mit, tA)AlAs5 r Soma- � y 10s 1 CkcE i-7F-KoArr eivrionkr, j u4 Inspector: Date: o �� O El $60.00 REINS ECTION FEE R QUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ..lw .i_oa_.a_i.. .- • afwy.laaala _an._+eac...�a._w...a..�� ...� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'E. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: Address: 320 S(oec. T Date Called: Special Instructions: Date Wanted: vZ/ :m: Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. if— COMMENTS: P� 71120 hTYj Inspector: 6OJA/CA Li $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee mist be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 07-120 10 Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION R INSPECTION RECORD Retain a copy with permit PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: 3A4 K. O� jj - -6t Type of Inspection: 700 \ Address: 37. o %2■ Date Called: Special Instructions: Date Wanted: Z 1�j } p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: vaD a-oJ4J Foi DiLivf. -Rik) ATtI 6RIO 040 F 10 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPEC7tON NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit /✓L 6.01_ o N PERMIT NO. (206)431 - 67 Project: 50.4 � aF��Ili4 Type of Inspection: ?ooh J Address: 32 0 Sr-k4"1" Date Called: Special Instructions: Date Wanted: rdoc e.,11.. Requester: Phone No: EjApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: LOA' JAIDC-fe.si.acs 654DJITS Inspector: eli &rider\ Date: Oz OS El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: M�- r�es�►Iki. rillx.� i�k..a,;.:'��,.G..w..�t,,... _� � _.rte. �.:.e.dl�....:a..., a.acy �...�R,�,li � - - 7r - - � INSPECTION RECORD Retain a copy with permit f 1017"-, / INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: i /WA ,'af AZ1176 /9 Type of Inspection: 7r0 Address: if Date Called: Special Instructions: w Date Wanted : / / , m., Requester: Phone No: ;,± roved per applicable codes. D Corrections required prior to approval. COMMENTS: be). (1)4 - iif# &41tif 7' Ins O ,YU ,30714/7144/6/i Dal/ ) /0? ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2 NSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I ft,a-lot's Project: I(0( �ek �j Type of Inspection: QO o..K - S4A-6 C94! fly 3 Address: 35 � A4 Date Called: are: - mid Otik 1b Rt- vtt nr 1 . Special Instructions: - Kcc ■ 2F ca 'r C, 1;22.£ i Date Wanted: o, 2� / aa.m. m Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. /I COMMENTS: CA . o..K - S4A-6 C94! fly 3 Case LIN &5 Sd-G A11) A,t r Weir 510e are: - mid Otik 1b Rt- vtt nr CI- oil tt-PPeoV ep Kdfk pi Eta 6iR.t41_ - Kcc ■ 2F ca 'r C, 1;22.£ i Inspector: s7 Date: bt f 22.f0 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: •••: • •7•v... ' S_. gee ha. a.— -- 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit EL 01- - ioI`� PERMIT N. (206)431 -3670 Project:/) a��f� V°y Type of Inspection: - 'heir 700/ X 3/d1 " ra 041-T 1-T A 41> 410— atile Address: 3205 44° Date Called: Special Instructions: Date Wanted: 01 1 3 a.m. p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: a. - 'heir ■ la. 56vlca 5rvii iPs 44P X 3/d1 " ra 041-T 1-T A 41> 410— atile Inspector: Aler\ ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Calf to schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address BoA- southcenter Branch Relocation Date 6/27/2008 320 Strander Blvd. For Building Department Use Tukrilla, WA 98188 Applicant Name: clumac, Tatyana Mike'adze Applicant Address: 1325 4th Ave. Seattle, WA 98101 Applicant Phone: 206- 262 -8375 Fe. C ;PY it Mo. r REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUL 2 9 2008 �6f Tukwila B ILDIN D It 0 RECEIVED CITY OF TUKWLA JUL 18 2008 PERMIT CENTER • 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary, LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address BoA- southcenter Branch Relocation Date 6/27/2008 320 Strander Blvd. For Building Department Use Tukrilla, WA 98188 Applicant Name: Glumac, Tatyana Mikeladze Applicant Address: 1325 4th Ave. Seattle, WA 98101 Applicant Phone: 206- 262 -8375 Project Description CENTRAL ZONE 0 New Building • Addition • Alteration • Pians Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive O Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 4 32.0 • No changes are being made to the lighting KITCHEN • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 — Area Area in ft2 Allowed x Area MAIN BUILDING RETAIL BANKING 1.50 7451.0 11176.5 CENTRAL ZONE TYPE "B " / "BE" - FLUORESCENT DOWNLIGHT 90 40.0 3600.0 TELLER TYPE "C" - LINEAR FLUORESCENT 4 32.0 128.0 "' From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt 11176.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed VAULT TYPE "A " /"AE" - 2'X4' RECESSED FLUORESCENT 5 115.0 575.0 CENTRAL ZONE TYPE "B " / "BE" - FLUORESCENT DOWNLIGHT 90 40.0 3600.0 TELLER TYPE "C" - LINEAR FLUORESCENT 4 32.0 128.0 KITCHEN TYPE "D" - UNDERCABINET 5 32.0 160.0 VAULT LOBBY TYPE "Dl" - UNDERCABINET 1 17.0 17.0 CALL CB /OFFICE TYPE "E " / "EE" - 2'X4' RECESSED FLUORESCENT 22 62.0 1364.0 TELLER TYPE "F" /"FE" - LINEAR FLUORESCENT 3 62.0 186.0 NER ROOM TYPE "H " / "HE" - LINEAR FLUORESCENT 5 62.0 310.0 TELLER TYPE "M " / "ME" - RECESSED FLUORESCENT 13 62.0 806.0 CENTRAL ZONE TYPE "N" - COVE LIGHTING 14 32.0 448.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt 7594.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may alsc used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. • 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Proj Addrest ,- Southcantar Branch Relocation Date 6/27/2008 320 Strander Blvd. For Building Department Use Tukwilla, WA 98188 Name: Glwaac, Tatyana Mikeladze Appl. Name:1325 4th Ave. Seattle, WA 98101 Appl. Phone 206- 262 -8375 Project Description Canopies and Overhangs FA New • Addition • Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Q Lighting Power Allowance Q Systems Analysis Building Grounds (luminaires > 100 Watts) 0.2 W/ft2 motion Sensor • Efficacy > 60 lumens/W ■ Controlled by Main Entry • Exemption (list) 10.0 300.0 Alteration Exceptions (check appropriate box - sec. 1132.3) 208.0 • No changes are being made to the lighting • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per ft2 or per If Area (f12), perimeter (10 or # of items Allowed Watts x ft2 (or x If) Automated Teller DRIVE TRRU 270W + 90W per adc 3.0 450.0 Bldg. Facade (by perim) Canopies and Overhangs DRIVE TRHU 1.25 W/ft2 4978.0 6222.5 Grounds Walkways >10' wide FRNT OF THE BUILDING WALKWAYS 0.2 W/ft2 2134.0 426.8 Main Entry MAIN DOOR 30 W /LF of door widt 10.0 300.0 Tradable Proposed Lighting Wattage Total Allowed Watt 6949.3 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Automated Teller DRIVE TRRU 270W + 90W per adc 3.0 450.0 Bldg. Facade (by perim) Grounds Walkways <10 wide TYPE "OE" IN -GRADE 4 208.0 832.0 Grounds Walkways >10' wide TYPE «0G^ EALLARDS 4 32.0 128.0 Canopies and Overhangs TYPE "J" 28 213.0 5964.0 Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watt 6924.0 Non - Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (10 or # of items Allowed Watts x ft2 (or x 1) Automated Teller DRIVE TRRU 270W + 90W per adc 3.0 450.0 Bldg. Facade (by perim) 5.0 W/If 212.0 1060.0 TYPE "J" 2 213.0 Non - Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Automated Teller TYPE "K" - SIGN EXEMPT (1532.A) Automated Teller TYPE "J" 2 213.0 426.0 Bldg. Facade (by perim) TYPE "OD" IN -GRADE 4 208.0 832 .0 Proposed Watts may not exceed Allowed Watts for Category 2006 Washington State Nonresidential Enerav Code Compliance Form Lighting, 2006 Washington State Motor, and Tra;n;sformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address BoA- Southcenter Branch Relocation Date 6/27/2008 The following information is necessary to check a permit application for compliance with the lighting, motor. and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Requires Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513 yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch yes 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w /backup Indicate location yes (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts 'indicate watts for each exit sign I ' LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture yea 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) ' 1511 Elec motor efficiency'MECH -MOT or Equipment Schedule with hp. rpm, efficiency ' TRANSFORMERS (Section 1540) ' 1540 'Transformers 'Indicate size and efficiency I ' If "no" is circled for any question, provide explanation: Conformity Services June 30, 2009 Allied Fire and Security 530 NE Couch Street Portland, WA 98232 Attention: Mr. Jim Walter Seattle Area Office 2222 West Valley Highway N Ste 160 Auburn WA 98001 (253) 736 -6010 (253)- 736 -6015 Subject: Equipment Labeling Evaluation, Final Report Pneumatic Air Tube Conveyor System eti Conformity Services Reference No.: 3102212F Dear Mr. Walter: Enclosed please find one copy of the subject report, as prepared by eti Conformity Services Compliance Engineer, Gil Parayno. The equipment evaluated in this report has been inspected for general compliance with applicable codes and standards and with regard to general electrical safety. Details of this evaluation are provided in this report. The equipment was fully operational and all the required field tests were performed during this site inspection. Please contact us if you have any questions or if we can be of further service on this or other projects. Sincerely, eti Conformity Services Marc Bothel Service Center Manager cc: Mr. Doug Griffith, Electrical Supervisor, Tukwila Office Enclosures • ik Conformity Services Seattle Area Office 2222 West Valley Highway N Ste 160 Auburn WA 98001 (253) 736 -6010 (253)- 736 -6015 i EQUIPMENT FIELD EVALUATION PRELIMINARY REPORT Pneumatic Air Tube Conveyor System At Bank of America 320 Strander Blvd. TUKWILA, WA 98188 CLIENT Allied Fire and Security 530 NE Couch Street Portland, WA, 98232 INSPECTION AUTHORITY Tukwila Office Electrical Inspector: Robert Benedicto L & I No.: 09 -407 Reference No.: 3102212F Submitted By: Gil Parayno Compliance Engineer Date: June 30, 2009 Reviewed By: 7friete-13.04145 Marc Bothel Service Center Manager CLIENT Allied Fire and Security 530 NE Couch Street Portland, WA, 98232 INSPECTION AUTHORITY Tukwila Office Electrical Inspector: Robert Benedicto L & I No.: 09 -407 Reference No.: 3102212F Submitted By: Gil Parayno Compliance Engineer Date: June 30, 2009 Reviewed By: 7friete-13.04145 Marc Bothel Service Center Manager TABLE OF CONTENTS 1.0 Purpose 2.0 Summary 3.0 General Conditions of Acceptance 4.0 Referenced Electrical Standards 5.0 Equipment Inspected 6.0 Inspection Procedures 7.0 Equipment Evaluation 8.0 Testing Results and Equipment APPENDIX A Summary of Project Contacts B Field Evaluation Data Sheets C Drawings D Photograph Page 1 Page 1 Page 1 Page 2 Page 2 Page 3 Page 5 Page 9 Page Al -A2 Page B1 -B2 Pages C1 -C3 Pages D1 1.0 PURPOSE The purpose of these inspections and tests is to provide assurance that custom or non - certified equipment meets the requirements of the appropriate codes, safety orders and industry standards. These inspections and tests are normally required by the local building inspection authority having jurisdiction (AHJ) when equipment has not been certified by a Nationally Recognized Testing Laboratory (NRTL) or other recognized testing agency. These inspections address only the electrical systems on the equipment listed in Section 5.0 of this report. 2.0 SUMMARY This project was initiated at the request of Mr. Jim Walter with Allied Fire and Security. Final inspection of the equipment referenced in Section 5.0 was performed at Bank of America, 320 Strander Blvd. in Tukwila, WA by eti Conformity Services Compliance Engineer Gil Parayno on June 30, 2009. Some electrical discrepancies were observed as described in Section 7.6. All discrepancies were corrected. Field measurements were taken by eti Conformity Services as detailed in Section 8.0. These measurements were within manufacturer's specifications. eti Conformity Services considers this equipment to be in compliance with electrical codes and standards listed in Section 4.0, pursuant to the conditions of acceptance described in Section 3.0. An eti Conformity Services equipment label has been affixed to the equipment. Note that final approval is under the jurisdiction of the City of Tukwila. 3.0 GENERAL CONDITIONS OF ACCEPTANCE In the event of modifications resulting in a change in the materials, manufacturing methods, loading, or environment that would affect the use of the accepted equipment under the provisions of the noted electrical standards, this acceptance will be considered automatically canceled. The applicant will be required to request re- examination of this equipment to determine acceptability of the modifications. By acceptance of the equipment referenced in Section 5.0, eti Conformity Services does not assume or discharge the responsibility of the equipment manufacturer, installer, or other relevant parties. Equipment evaluation is based upon adherence to sound engineering practices, and upon compliance with the specific sections quoted from the electrical standards referenced in Section 4.0 of this report. eti Conformity Services Reference No.: 3102212F Page 1 Assessment of required interrupting rating and arc -flash labeling of the equipment being evaluated is beyond the scope of this field evaluation. Determining the adequacy of interrupting rating and arc -flash labeling are the responsibility of the end -user as described in subsection 6.5 of this report. This acceptance applies to the electrical circuits and components only, as referenced in this report. Unless noted otherwise, it specifically excludes examination for suitability of use for equipment involving toxic or corrosive gases, steam, and locations defined as hazardous by the National Electrical Code (NEC ®). 4.0 REFERENCED ELECTRICAL STANDARDS 4.1 UL 508, Industrial Control Equipment, 17th Edition, Revisions through December 2, 2003 4.2 UL 508A, Industrial Control Panels, 1st Edition, Revisions through May 1, 2003 4.3 ANSI /NFPA 79, Electrical Standard for Industrial Machinery, 2002 4.4 ANSI /NFPA 70, (NEC ®) National Electrical Code 2005 5.0 EQUIPMENT INSPECTED 5.1 One (1) Pneumatic Air Tube Conveyor System Manufacturer Name: Hamilton Air Products Model No.: HA -33 Serial No.: 758 Ratings: 120 Vac, 30 Amps, 60 Hz, 1- phase, 3 -wires eti Label No.: 0119089 5.2 Two (2) Customer/Teller Service Station Manufacturer Name: Hamilton Air Products Model No.: HA -33 Serial No.: 752 Ratings: 120 Vac, 30 Amps, 60 Hz, 1- phase, 3 -wires eti Label Nos.: 0119676, 0119677 eti Conformity Services Reference No.: 3102212F Page 2 6.0 INSPECTION PROCEDURES 6.1 Component Listing The following major power components are inspected for listing marks by an independent testing laboratory acceptable to the authority having jurisdiction (AHJ), or are evaluated to the appropriate nationally recognized consensus standard. Any discrepancies observed during the evaluation process are noted in Section 7.0. • Circuit breakers • Fuses and fuseholders • Disconnect switches • Terminal blocks • Pushbuttons and switches • Relays and contactors 6.2 Visual Inspection • Transformers • Motors and drives • Motor overload units • Wire ducts • Receptacles • Cables and wiring The equipment is visually inspected with particular attention to the following areas: • Manufacturer nameplates • Use of "approved" components • Proper overcurrent protection • Wiring ampacity • Ground bonding 6.3 Ground Bonding • Electrical ratings • Wiring methods • Guarding of live parts • Damaged components • General engineering practices Exposed non - current carrying parts of the equipment are inspected for effective grounding in accordance with the applicable provisions of the standards referenced in Section 4.0 and the National Electrical Code (NEC ®) Article 250. eti Conformity Services Reference No.: 3102212F Page 3 6.4 Guarding of Live Parts All internal components are inspected for installation in a suitable enclosure and effective guarding in accordance with the standards referenced in Section 4.0 and the National Electrical Code (NEC ) Section 110.27. 6.5 Overcurrent Protection Overcurrent protection installed in this equipment is evaluated for compliance with the applicable codes and standards referenced in Section 4.0. Protective devices are verified to be properly identified, and of a type suitable for the circuit applications as installed. Please note: Determining the adequacy of interrupting rating and arc - flash labeling are the responsibility of the end -user and are therefore outside the scope of this field evaluation project. The customer is hereby advised of NFPA 70 -2005, Articles 110.9 & 110.16 which state: 110.9 Interrupting Rating. "Equipment intended to interrupt current at fault levels shall have an interrupting rating sufficient for the nominal circuit voltage and the current that is available at the line terminals to the equipment." "Equipment intended to interrupt current at other than fault levels shall have an interrupting rating at nominal circuit voltage sufficient for the current that must be interrupted." 110.16 Flash Protection. "Switchboards, panelboards, industrial control panels, meter socket enclosures, and motor control centers that are in other than dwelling occupancies and are likely to require examination, adjustment, servicing, or maintenance while energized shall be field ma-ked to warn qualified persons of potential electric arc flash hazards. The marking shall be located so as to be clearly visible to qualified persons before examination, adjustment, servicing, or maintenance of the equipment." eti Conformity Services would be happy to provide a proposal for above services upon receiving a request from the customer. 6.6 Internal Wiring Internal wiring and wiring methods are evaluated for compliance with the applicable codes and standards referenced in Section 4.0. Wiring is verified to be properly sized and rated, with a temperature rating suitable for the installed application. eti Conformity Services Reference No.: 3102212F Page 4 6.7 Safety Interlocks and Operator Controls The equipment safety interlocks, emergency stops, operator controls and human machine interfaces (HMI) are verified to be properly identified. The safety features and emergency machine off (EMO) switches are tested for proper operation. 6.8 Field Testing Field testing is performed on the equipment, to meet the field testing requirements of the standards referenced in Section 4.0, unless production test results have been provided by the equipment manufacturer and accepted by eti Conformity Services. If no production tests are submitted, then testing is performed to verify the equipment to be operating within normally expected parameters as detailed in Section 8.0. 7.0 EQUIPMENT EVALUATION 7.1 One (1) Pneumatic Air Tube Conveyor System 7.1.1 System Description The equipment inspected consists of one (1) Pneumatic Air Tube Conveyor System manufactured by Hamilton Air Products. The equipment is rated at 120 Vac, 30 Amps, 60 Hz, 1- phase, 3 -wires and is used to provide air flow that moves the cannister from inside the bank out to the customer in their car. The equipment is installed indoors in an ordinary (non- hazardous) location, and has been evaluated for use in this location only. 7.1.2 Grounding Exposed non - current carrying parts of the equipment were verified to be effectively grounded in accordance with the applicable provisions of NEC ®, Article 250. 7.1.3 Guarding of Live Parts All internal components are enclosed in a grounded, screw closed, metal enclosure, and are effectively guarded per NEC ®, Section 110.27. eti Conformity Services Reference No.: 3102212F Page 5 7.1.4 Overcurrent Protection Overcurrent protection was provided by a 30 Amps circuit breaker from the panelboard and branch overcurrent protection of 20 Amp fuses for each motor. 7.1.5 Wiring All wiring was found to be UL listed or recognized type MTW/THHN or equivalent. 7.1.6 Equipment Discrepancies The discrepancies observed during the evaluation of the equipment listed in Section 5.0 were as described below. These items require corrective action in order to successfully complete the final acceptance of the equipment. .01 Warning - Disconnect Power This enclosure was not provided with a cautionary marking warning of the hazardous voltages contained within. Action: A cautionary marking shall be installed in a plainly visible location on the outside of the enclosure stating the following or equivalent: No. 111101?O11- B10NP_ (Available Sizes: 8,1:11) Reference: UL 508, Paragraphs 65.1 -65.3 NFPA 79, 17.2.1 NEC ®, Section 110.3(a)(8) Correction: Danger / Warning sign was installed as required eti Conformity Services Reference No.: 3102212F Page 6 .02 Control Panel Nameplate (missing) This control panel is not provided with the required nameplate. Action: A permanent nameplate shall be installed where plainly visible. The nameplate shall be suitable for the environment and shall contain the following information as a minimum: a) Manufacturer's name or trademark b) Equipment catalog or serial number c) Electrical ratings including voltage, amperes, horsepower, volt- amperes or any combination thereof, frequency and number of phases. Reference: UL 508, Paragraph 63.1 UL 508A, Paragraphs 52.1 -52.4 NFPA 79, 17.4 Correction: A new nameplate was installed as required. 7.2 Two (2) CustomeNTeller Service Station 7.2.1 System Description The equipment inspected consists of two (2) Service Stations for a customer and a teller manufactured by Hamilton Air Products. The equipment is rated at 120 Vac, 10 Amps, 60 Hz, 1- phase, 3 -wires and is used to send and recall a canister between the customer from their car and the teller inside the bank. The equipment is installed indoors in an ordinary (non- hazardous) location, and has been evaluated for use in this location only. 7.2.2 Grounding Exposed non - current carrying parts of the equipment were verified to be effectively grounded in accordance with the applicable provisions of NEC ®, Article 250. eti Conformity Services Reference No.: 3102212F Page 7 7.2.3 Guarding of Live Parts All internal components are enclosed in a grounded, screw closed, metal enclosure, and are effectively guarded per NEC ®, Section 110.27. 7.2.4 Overcurrent Protection Overcurrent protection was provided by a 20 Amps circuit breaker from the panelboard and branch overcurrent protection of 10 Amp fuses for each motor. 7.2.5 Wiring All wiring was found to be UL listed or recognized type MTW/THHN or equivalent. 7.2.6 Equipment Discrepancies The discrepancies observed during the evaluation of the equipment listed in Section 5.0 were as described below. These items require corrective action in order to successfully complete the final acceptance of the equipment. .01 Control Panel Nameplate (missing) This control panel is not provided with the required nameplate. Action: A permanent nameplate shall be installed where plainly visible. The nameplate shall be suitable for the environment and shall contain the following information as a minimum: d) Manufacturer's name or trademark e) Equipment catalog or serial number f) Electrical ratings including voltage, amperes, horsepower, volt- amperes or any combination thereof, frequency and number of phases. Reference: UL 508, Paragraph 63.1 UL 508A, Paragraphs 52.1 -52.4 NFPA 79, 17.4 eti Conformity Services Reference No.: 3102212F Page 8 Correction: A new nameplate was installed as required. .02 Warning - Disconnect Power This enclosure was not provided with a cautionary marking warning of the hazardous voltages contained within. Action: A cautionary marking shall be installed in a plainly visible location on the outside of the enclosure stating the following or equivalent: No. J '1O40lf -49 { Skov: S,7,11) Reference: UL 508, Paragraphs 65.1 -65.3 NFPA 79, 17.2.1 NEC ®, Section 110.3(a)(8) Correction: Warning signs were installed as required. 8.0 TESTING RESULTS AND INSTRUMENTS 8.1 Field Testing The following field- testing was completed with the summary results as indicated. Please refer to the Product Evaluation Data Sheet in Appendix B in this report for complete details on the specific tests completed. 8.1.1 Current and Voltage Measurements Current and voltage measurements were taken at the input to each piece of equipment listed in Section 5.0 under normal operating conditions. The measurements obtained were verified to be within the voltage and current ratings of the devices installed. The results found all measurements were to be satisfactory and within an acceptable operating range. eti Conformity Services Reference No.: 3102212F Page 9 8.1.2 Temperature Rise Test A temperature rise test was performed on all components within each piece of equipment listed in Section 5.0 under normal operating conditions. The test was performed using an infrared (I.R.) thermometer to verify the temperature rise for each component did not exceed those specified in UL 508. Temperatures obtained were verified to be sufficiently low enough not to constitute risk of fire or to adversely affect any material employed in the equipment. The temperature rise obtained for each component is a result of test conditions only and is not necessarily indicative of the possible temperatures generated in the operating environment. The results of the temperature rise tests found the recorded value to be less than the maximum rise allowed by the standard. 8.1.3 Insulation Resistance Test An insulation resistance test was performed on the equipment listed in Section 5.0 to verify the dielectric integrity of the insulating medium. Voltage was applied phase to ground at 1000 Vdc Volts DC for 1 minute on the incoming supply conductors of each piece of equipment tested. There were no indications of insulation breakdown as evidenced by arcing, sparks and therefore the test results indicate satisfactory results.Field testing was not performed at the time of the preliminary inspection. Testing will be performed during the final inspection as described in section 6.8. 8.2 Test Equipment All equipment has been calibrated to NIST reference standards. Certificates of calibration are available upon request. • . : ToSt Equiipnneint ° : .• .; Mocdel .; . °gti; sset fro. .Calibration Date Fluke, True RMS Multimeter 87 III 20 -01670 April, 2009 Fluke AC Current Probe 80i -600 20 -01673 PCNR AEMC AC Current Probe MN106 20 -01672 PCNR Raytek Infrared Thermometer ST -30 20 -01669 April , 2009 AVO Megger BM400 /2 20 -01671 April, 2009 Performance Digital Caliper W80152 20 -1850 April, 2009 Chicago Digital Micrometer 50050 20 -1854 April, 2009 Note: PCNR = "periodic calibration not required ". eti Conformity Services Reference No.: 3102212F Page 10 eti Conformity Services: Reference No. Name: Address: City, State, Zip: Phone: Fax: Compliance Engineer: Client Information: Company Name: Street Address: City, State, Zip: Phone: Contact: Purchase Order No: Site Information: Site Name: Street Address: City, State, Zip: Phone: Site Contact: Jurisdiction Information: Inspector's Name: Jurisdiction: L &I No: Appendices APPENDIX A Summary of Project Contacts 3102212F Seattle Area Office 2222 West Valley Highway N Ste 160 Auburn WA 98001 (253) 736 -6010 (253)- 736 -6015 Gil Parayno Allied Fire and Security 530 NE Couch Street Portland, WA 98232 503 - 866 -5090 Mr. Jim Walter 104990 Bank of America, Tukwila 320 Strander Blvd. Tukwila, WA 98188 -2939 206 -963 -3770 Mr. Tony Cegon Mr. Doug Griffith, Acting Supervisor Tukwila Office 09 -407 Manufacturer's Information: 1. One (1) Pneumatic Air Tube Conveyor System Manufacturer Name: Hamilton Air Products Model No.: HA -33 Serial No.: 758 eti Label No.: 0119089 2. Two (2) Customer/Teller Service Stations. Manufacturer Name: Hamilton Air Products Model No.: HA -33 Serial No.: 752 eti Label Nos.: 01190676, 0119677 Appendix D1 Hamilton Pneumatic Vacuum /Pressure Assembly Nameplate of the pneumatic system control panel Component layout of the control panel Warning signinstalled at the front cover of the control panel Typical assembly of the customer and teller service station Nameplate and warning sign installed for each service station Conformity Services PRODUCT EVALUATION TEST DATA CLIENT: Allied Fire and Security IETI JOB NUMBER: 3102212F LOCATION: 320 Strander Bvld. Tukwila, WA ENGINEER: Gil Parayno DATE: 06/30/2009 EQUIPMENT: 5.1 Hamilton Air Pneumatic Tube Air Conveyor System MODEL: HA -33 SERIAL NO: 758 RATINGS: 120 VOLT DATE: 30 AMPS INSULATION RESISTANCE TEST VOLTAGE: 1000 VDC 60 HZ 1 TEST DATA (MEG -OHMS) TEST EQUIP ASSET #: 1 I • PHASE 3 WIRE CALIBRATION DATE: 04/30/09 PHASE TO GROUND PHASE TO PHASE CIRCUIT IDENTIFICATION A B C A -B B -C C -A Incoming /disconnect >1000 VOLTAGE AND CURRENT DATE: TEST METHOD: TEST EQUIP N/A READINGS ASSET #: II • • CALIBRATION DATE: April 30, 2009 VOLTAGE MEASUREMENTS CURRENT MEASUREMENTS PHASE A -N PHASE B -N PHASE C -N PHASE A -B PHASE B-C PHASE C-A PHASE A PHASE B PHASE C NEUTRAL GROUND 121.5 Vacuum Pump 19.8 Pressure Pump 19.9 REMARKS: DATE: COMPONENT TEMPERATURE AMBIENT TEMP: 18 °C RISE DATA TEST EQUIP ASSET #: • -• • • • CALIBRATION DATE: , • I 8.• COMPONENT IDENTIFICATION COMPONENT TEMP. TEMPERATURE RISE TEST METHOD Incoming wire 20 2 Infrared Transformer TF1 -18 Infrared Power supply -18 Infrared Overload RIy. -18 Infrared Fuses 20 2 Infrared Magnetic contactor 22 4 Infrared EMO FUNCTION TESTS EMO AND INTERLOCK TESTS INTERLOCK FUNCTIONAL TESTS Infrared DATE: DATE: LOCATION RESULT INTERLOCK DESCRIPTION RESULT INTERLOCK DESCRIPTION RESULT LEAKAGE Location Resistance CURRENT (Ohms) AND RESISTANCE Voltage (mV) Leakage Current (mA) GENERAL NOTES I ETI LABEL #0119089 NUMBER(s) eti 2000 F/6001 rev. 3100 A = Acceptable, N/A = Not Applicable, C = Corrected, R = Needs Repair Page B -1 ati Conformity Services PRODUCT EVALUATION TEST DATA CLIENT: Allied Fire and Security IETI JOB NUMBER: 3102212F LOCATION: 320 Strander Bvid. Tukwila, WA ENGINEER: Gil Parayno DATE: 06130/2009 EQUIPMENT: 5.1 Hamilton Air Pneumatic l Service Station System MODEL: HA -33 SERIAL NO: 752 RATINGS: 120 VOLTS 10 AMPS INSULATION RESISTANCE DATE: TEST VOLTAGE: 1000 VDC 60 HZ 1 TEST DATA (MEG -OHMS) TEST EQUIP ASSET #: 1 -1 c PHASE 3 WIRE CALIBRATION DATE: 04/30/09 PHASE TO GROUND PHASE TO PHASE CIRCUIT IDENTIFICATION A B C A -B B -C C -A Incoming /disconnect >1000 VOLTAGE AND DATE: TEST ME HOD: N/A CURRENT TEST EQUIP READINGS ASSET #: a -• ; 1 CALIBRATION DATE: April 30, 2009 VOLTAGE MEASUREMENTS CURRENT MEASUREMENTS PHASE A -N PHASE B -N PHASE C -N PHASE A -B PHASE B -C PHASE C -A PHASE A PHASE B PHASE C NEUTRAL GROUND 121.5 Customer 8.48 Pressure Pump 8.48 REMARKS: DATE: COMPONENT TEMPERATURE AMBIENT TEMP: 18 °C RISE DATA TEST EQUIP A SET #: • 0 ■• " CALIBRATION DATE: 1, 0 IV' COMPONENT IDENTIFICATION COMPONENT TEMP. TEMPERATURE RISE TEST METHOD Incoming wire 19.5 1.5 Infrared Transformer TF1 Infrared Power supply Infrared Overload Riy. Infrared Fuses 19 1 Infrared Magnetic contactor Infrared EMO FUNCTION TESTS EMO AND INTERLOCK TESTS INTERLOCK FUNCTIONAL TESTS Infrared DATE: DATE: LOCATION RESULT INTERLOCK DESCRIPTION RESULT INTERLOCK DESCRIPTION RESULT LEAKAGE Location Resistance CURRENT (Ohms) AND RESISTANCE Voltage (mV) Leakage Current (mA) GENERAL NOTES ETI LABEL Customer station NUMBER(s) #0119676 Teller station #0119677 ® eti 2000 F16001 rev. 3/00 A = Acceptable, N/A = Not Applicable, C = Corrected, R = Needs Repair Page B -2 Ppui3D t)( alt C4> A t E 17"-• 0 oo JA; # pVe' V k (- HA -33 Mark 2 Turbine Control Panel 33 turbine control panel.cnv Note: In Vacuum made (Teller Send) the Vacuum motor starter V1 pulls in first followed one second later by the pressure motor starter P1. In pressure mode (Customer send) the pressure motor starter pulls in first followed one second later by the vacuum motor starter. Copyright Hamilton Safe, 2003 J#; A- PPEA I)4, Cr- 3 3 Conductor Low voltage control cable 230 Vac 30 Amp with neutral or 2 circuits of 120 Vac 30 amp each 120 Vac 10A, Building Power Panel Turbine Assembly Located Above the Customer unit 120 Vac 10 amp Customer Unit 12 Conductor Low voltage control cable 6 conductor Audio Cable Audio Matrix Teller Unit Low Voltage & Audio Cables 1 each 12 conductor 18 ga control 1 each 3 conductor 18 ga control 1 each 6 conductor Audio 1 each 4 conductor Audio* * use 4 conductors of a 6 conductor cable 33 power & cable.cnv 4 conductor Audio Cable Power Requirements Teller Unit: 120 Volt AC 10 Amp Customer Unit: 120 Volt AC 10 Amp Turbine Unit: 2 Circuits 120 Volt AC 30 Amp each or 1 circuit 230 Volts AC 30 Amp with neutral 11/14100 HA -33 Power and Cable Details © Copyright Hamilton Safe, 2003 PERMIT COORD COPY PLAN REVIEW /ROUTING SUP ACTIVITY NUMBER: EL08 -1018 DATE: 07 -18 -08 PROJECT NAME: BANK OF AMERICA SITE ADDRESS: vtvtAkA7 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: 4)15 Building Division Public Works n Fire Prevention Structural Planning Division nPermit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: DUE DATE: 07 -22-08 Incomplete n Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08 -19-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • Page 1 of 2 Electrical Contractor A business licensed by LBtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company S M E INC OF SEATTLE 2063292040 828 POPLAR PL S SEATTLE WA 98144 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License PACIFFS973PU Associated License BAKERJT973LR Specialty 1 GENERAL Specialty 2 UNUSED 601524252 ACTIVE SMEINS*066DB ELECTRICAL CONTRACTOR 3/2/1994 3/2/2010 MASTER ELECTRICIAN INFORMATION License BAKERJT973LR Name BAKER, JON T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MARVICH, STEPHEN E Cancel Date 01/01/1980 Bond Amount PINSKY, ADAM A 01/01/1980 BAKER, JON T AGENT 01/01/1980 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date Until https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License= SMEINS * 066DB 10/23/2008 DEPARTMENT OF LABOR AND INDUSTRIES LICENSED AS PROVIDED BY LAW AS ELEC CONTR GENERAL SMEINS *066DB EXP D S M E INC OF SEATTLE, 828 POPLAR. PL S SEATTLE WA 98144 F625- 052 -000 (8/97) Detach And Display Certificate LICENSED .AS PROVIDED "BY LAW AS ELEC CONT-R" GENERAL "" LICENSE ;# EXP "': DATE `►ATE S -M E :I 828 POP: SEATTLE'' Signature Issued by DEPARTMENT OF LABOR AND INDUSTRIES / F625- 052 -000 (8/97) Please Remove And Sign Identification. Card Before Placing In Billfold 1 an of America Southcenter Branch Relocation Permit / Bid Set -June 20, 2008 ELECT ICAL PERMIT SET 320 Strander Blvd, Tukwila WA FILE COPY Permit No. Pier review approval is subject to enbrs and moons. Approval of construction doctunents does not authorize the vitiation of any adopted coda orb. Receipt o+ approved Copy and conditions is acknowledged: By Date. l u - z 3 - 08 City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. SEPARATE PERMIT REQUIRED FOR ter Mechanical O Electrical (Plumbing BF Gas Piping City of Tukwila BUILDING DIVISION Gensler Architect 1524 Fifth Avenue Suite 300 Seattle WA 98101 Telephone: 206.654.2100 Facsimile: 206.654.2121 PROJECT DESCRIPTION SCALE: 1 : 1 CONSTRUCTION OF A NEW ONE STORY BANK BRANCH BUILDING WITH DRIVE THRU CANOPY ON A RETAIL PAD PROJECT. INFORMATION SCALE: 1 /8° =1' -0" BUILDING ADDRESS: 320 STRANDER BLVD, TUKWILA WA BUILDING CODE: 2006 INTERNATIONAL BUILDING CODE(IBC); WITH WASHINGTON STATE AMMENDMENTS OCCUPANCY TYPE: B- OFFICE CONSTRUCTION TYPE: TYPE VA, FULLY SPRINKLERED BUILDING AREA PROPOSED: 7,451 SF (BUILDING) + 4,327 SF (EXT CANOPY) = 11,778 SF TOTAL BUILDING AREA -MAX: PROJECT DATUM: FIRE PROOFING: ZONING: BUILDING HT- PROPOSED: BUILDING HT -MAX: 36,167 SF TOTAL PER STORY FF EL= 26' -6" NONE TUKWILA URBAN CENTER (TUC) SINGLE STORY; 20' -0" ABOVE GRADE AT ENTRY 115' -0" SHEETS E00.01 E00.02 E01.01 E02.01 E03.01 E03.02 E05.01 E06.01 ELECTRICAL ELECTRICAL LEGEND ELECTRICAL SCHEDULES SITE PLAN - ELECTRICAL LEVEL 01 CONSTRUCTION PLAN - LIGHTING LEVEL 01 CONSTRUCTION PLAN - POWER ROOF PLAN - POWER ELECTRICAL RISER DIAGRAM DETAILS - ELECTRICAL RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER VICINITY MAP ........... ...... .................... is x fr Cop rake f 7 -N7 TE ty Q: \_ 2007 — Jobs \507048GEN.g2 \BOASOUTH— E00- 01.dwg 20 Jun 2008 — 1:25 pm tam ECTRICAL LEGEN REFER TO DETAILS FOR MOUNTING HEIGHTS OF DEVICES NOT ALL .SYMBOLS, ABBREV:, ETC: ARE NECESSARILY USED ON :THIS PROJECT LIGHTIN DISTRIBUTION & EQUIPMENT SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL FERENCE SYMBOL DESCRIPTION SYMBOL IRE ALARM SYSTE DES' ESCRIPTION 1•V' PTA I;;[•;;; 1■ - - - -• 3c PTA 3A SHADING OF ANY LUMINAIRE INDICATES CONNECTION TO ALTERNATE POWER SOURCE (EMERGENCY, UPS, STANDBY, ETC.) PER CIRCUITING INDICATED ILLUMINATED EXIT SIGN, SHADED QUADRANT INDICATES FACES, ARROWS AS SHOWN LUMINAIRE MARKING CONVENTION LEGEND: PTA = LUMINAIRE TYPE IDENTIFICATION. SEE LUMINAIRE SCHEDULE. 3c = CIRCUIT NUMBER VIA LOCAL SWITCH (LOWERCASE LETTER) THAT SERVES THE LUMINIARE. 3A = CIRCUIT NUMBER /UPPERCASE LETTER COMBINATION INDICATES LOW VOLTAGE RELAY OR LIGHTING CONTACTOR THAT SERVES THE LUMINAIRE SYMBOL DESCRIPTION so LCP SINGLE POLE SWITCH (SUPERSCRIPT DENOTES SIMILARLY MARKED LUMINAIRES CONTROLLED TOGETHER) LOW VOLATGE SWITCH OCCUPANCY SENSOR - WALL MOUNTED 360 DEGREE OCCUPANCY SENSOR - CEILING MTD. COMBINATION OCCUPANCY SENSOR Sc SWITCH GANGED UNDER A COMMON COVER PLATE. OCCUPANY SENSOR TO CONTROL ALL LUMINAIRES IN ROOM WITH 1/2 UGHT REDUCTION CONTROLLED BY SWITCH, DESIGNATED BY LETTER. 2 -GANG BOX WITH SINGLE -GANG MUDRING, UON SPECIFIED LIGHTING CONTROL PANEL AND ASSOCIATED COMPONENTS. PROVIDE 120V OR 277V CONTROL POWER AS REQUIRED OR AS INDICATED. I BRANCH CIRCUIT PANELBOARDS, SURFACE AND RECESS MOUNTED, SOLID= 120/280V, HATCHED= 277/480V, DASHED EQUIP. = FUTURE MOTOR CONTROL CENTER W/ CODE CLEARANCES SHOWN, DASHED EQUIP. = FUTURE TRANSFORMER WITH CODE CLEARANCES SHOWN SERVICE AND /OR DISTRIBUTION EQUIPMENT WITH CODE CLEARANCES SHOWN CONNECTION TO MOTOR PROVIDED BY OTHERS CONNECTION TO DIV. 15 FURNISHED VARIABLE FREQUENCY DRIVE WITH INTEGRAL DISCONNECT DIV. 16 TO INSTALL VFD EQUIPMENT DIV. 16 CONNECTION TO EQUIPMENT PROVIDED BY OTHERS. REFER TO MECHANICAL COORDINATION SCHEDULES FOR REQUIREMENTS (DISCONNECTS, STARTERS, WIRING, ETC.). SHADED ON ALT. POWER. EQUIPMENT OR TERMINAL ENCLOSURE AS NOTED, SURFACE AND RECESS MOUNTED BUILDING GROUND BUS, SEE DETAILS DAMPER MOTOR SYMBOL DESCRIPTION TERMINAL /MOUNTING BOARD, 8' HIGH X WIDTH AS SHOWN, FIRE TREATED. SIGNAL SYSTEM EQUIPMENT ENCLOSURES AS NOTED - SURFACE, RECESSED MOUNTED TELEPHONE /DATA OUTLET -STUB 3/4" WITH PULL STRING TO 6' ABOVE CEILING (SINGLE GANG J -BOX) AB GFI WP +42" 0 0 SIMPLEX RECEPTACLE - WALL, CEILING, ON ALT. DUPLEX RECEPTACLE - WALL, CEILING, ON ALT. DOUBLE DUPLEX RECEPTACLE - WALL, CLG, ON ALT. DEDICATED RECEPTACLE - WALL, CEILING, ON ALT. RECEPTACLE TYPE SHOWN -WALL -ABOVE COUNTER BACKSPLASH. SEE ARCHITECTURAL DRAWINGS. DUPLEX RECEPTACLE - WALL - WITH INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER RECEPT. TYPE SHOWN W/ WEATHERPROOF COVER AND INTEGRAL GROUND FAULT CIRCUIT INTERRUPTER RECEPT. TYPE SHOWN AT SPECIAL HEIGHT FLUSH FLOOR BOX DEVICE - DEVICE TYPE PER SYMBOLS ABOVE PEDESTAL FLOOR DEVICE - DEVICE TYPE PER SYMBOLS ABOVE SYMBOL DESCRIPTION O -31E- rate DMU 100AT IT) 225AF BUS DUCT BUS BAR PIPE GROUND CONTACTOR COIL RELAY COIL CURRENT TRANSFORMER POTENTIAL TRANSFORMER UTILITY CO. APPROVED SOCKET WITH METER INSTALLED. SQUARE = REMOTE MOUNTED DIGITAL METER UNIT. DELTA CONNECTION GROUNDED WYE CONNECTION CONNECTION TO GROUND CIRCUIT BREAKER, WITH TRIP & FRAME AMPERE RATING 12 ( 125.4 ) EQUIP NAME SHEET NOTE REFERENCE BRANCH CIRCUIT OR FEEDER NOMINAL AMPACrrY & TYPE; REFER TO BRANCH CIRCUIT AND FEEDER SCHEDULES FOR WIRE AND CONDUIT SIZES & QTY. REFER TO DETAIL NO. ON DRAWING INDICATED NOT ALL DETAIL REFERENCES ARE SHOWN. ALL DETAILS APPLY TO ALL APPLICABLE SITUATIONS, UON. MECHANICAL EQUIPMENT IDENTIFICATION TAG EQUIPMENT BY OTHERS IDENTIFICATION TAG 7 E77:7 IRIN DESCRIPTION SYMBOL X X X X T -MV- -G -GC t L1A -1,3 HD1A ►00 4nnnnn^ WIRING CONCEALED IN CEIUNG OR WALL LINE WEIGHT TOP TO BOTTOM= NEW, EXISTING TO REMAIN, FUTURE WIRING CONCEALED IN FLOOR OR UNDER GRADE OR ROUTED IN CEILING SPACE OF FLOOR BELOW. LINE WEIGHT TOP TO BOTTOM= NEW, EXISTING TO REMAIN, FUTURE EXISTING WIRING TO BE REMOVED TELEPHONE SYSTEM CONDUIT MEDIUM VOLTAGE CONDUIT BARE GROUNDING GRID OR CONDUCTORS, UON. GROUNDING CONDUCTOR(S) ROUTED IN CODE SIZED CONDUIT, UON. STROKES INDICATE QUANTITY OF #12 AWG. CONDUCTORS, UON. NOTE: WIRING STROKES FOR 20A BRANCH CIRCUITS ARE NOT SHOWN ON DRAWINGS. CONTRACTOR SHALL USE INFORMATION IN PANEL AND BRANCH CIRCUIT SCHEDULES TO PROVIDE REQUIRED CIRCUITING. GROUND HOT NEUTRAL HOME RUN WIRING TO INDICATED DESTINATION, 3/4 "C. MIN. OR AS OTHERWISE NOTED. CONTRACTOR SHALL USE CIRCUIT SIZES NOTED IN RESPECTIVE SCHEDULES AND INFORMATION IN THE FEEDER AND BRANCH CIRCUIT SCHEDULES. CONDUIT RUN TURNED UP THROUGH FLOOR OR CEILING. CORE & FIREPROOF AS REQUIRED. CONDUIT RUN TURNED DOWN THROUGH FLOOR OR CEILING. CORE & FIREPROOF AS REQUIRED. CONDUIT STUBBED OUT AT LOCATION SHOWN. PROVIDE INSULATED BUSHING & PULLROPE. TELEPHONE /DATA SLEEVE THROUGH WALL, ABOVE CEILING. EXTEND TO ACCESSIBLE TILE CLG. BOTH SIDES. TERMINATE WITH BUSHINGS. (1) 1.25" CO UON. COORDINATE LOCATIONS WITH CABLE INSTALLER(S) PRIOR TO ROUGH -IN. JUNCTION BOXES, WALL, CEILING AND FLUSH FLOOR MOUNTED. 4" SQ. BOX MIN., LARGER IF REQUIRED PULL BOX, MIN. SIZE PER NEC., UON. FLEXIBLE CONDUIT CONNECTION r FIRE ALARM CONTROL PANEL AND ASSOCIATED COMPONENTS. PROVIDE 120V POWER AS REQUIRED OR AS INDICATED. SMOKE DETECTOR, DUCT MOUNTED, WITH FULL WIDTH SAMPLING TUBES. PHOTOELECTRIC TYPE SYMBOL DESCRIPTION -G- -GC • • • • • BARE GROUNDING GRID OR CONDUCTORS, UON. GROUNDING CONDUCTOR(S) ROUTED IN CODE SIZED CONDUIT, UON. GROUND GRID BOND POINT GROUND GRID BOND POINT - MECHANICAL CONNECTION GROUND GRID BOND POINT - EXOTHERMIC WELD CONNECTION 24" GROUND BAR 60" GROUND BAR GROUND ROD LOCATION GROUND ROD IN TEST WELL LECTRICAL BASIS OF DESI . THE ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM AS DETAILED IN THIS DRAWING SET AND AS REQUIRED BY ALL FEDERAL, STATE, AND LOCAL CODES AND STANDARDS INCLUDING BUT NOT LIMITED TO: A. AMERICANS WITH DISABILITIES ACT, (ADA) B. NFPA 101, UFE SAFETY CODE: 2005 C. BUILDING CODES ENFORCED BY THE AUTHORITY HAVING JURISDICTION IN TUKWILLA, WASHINGTON: 1. 2006 INTERNATIONAL FIRE CODE (IFC) WITH STATE AND CITY AMENDMENTS 2. 2005 NATIONAL ELECTRICAL CODE (NEC) 3. 2006 WASHINGTON STATE ENERGY CODE 4. 2006 INTERNATIONAL BUILDING CODE (IBC) WITH STATE AMENDMENTS. 2. LIGHTING DESIGN A. THE LIGHTING LAYOUT AND LUMINAIRE SELECTION WAS PERFORMED BY LITEWIRE 3. POWER DESIGN A. POWER DESEGN PERFORMED BY GLUMAC 4. TELECOMMUNICATIONS /AV /SECURITY SYSTEMS DESIGN A. THE ELECTRICAL CONTRACTOR IS TO PROVIDE AND INSTALL ALL RACEWAY, PULLSTRING, JUNCTION BOXES, ETC. AS REQUIRED FOR TELECOMMUNICATIONS, SECURITY AND AV SYSTEMS. COORDINATE EXACT REQUIREMENTS AND LOCATIONS WITH SYSTEM PROVIDERS, ARCHITECT AND OWNER PRIOR TO ROUGH -IN. 5. FIRE ALARM DESIGN A. FIRE ALARM DESIGN IS DESIGN /BUILD BY THE FIRE ALARM SYSTEM VENDER. DEVICES AND LAYOUT SHOWN ON THESE DRAWINGS ARE TO AIDE IN ARCHITECTURAL COORDINATION AND TO ESTABLISH A MINIMUM LEVEL FOR BIDDING PURPOSES. B. THE FIRE ALARM SYSTEM FOR THE TENANT SPACE SHALL MATCH AND INTERFACE WITH THE BUILDING -WIDE FIRE ALARM SYSTEM. COORDINATE REQUIREMENTS WITH BUILDING OPERATIONS MANAGER. C. FIRE ALARM CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL PARTS, PIECES, CONDUCTORS, EQUIPMENT, ETC. REQUIRED FOR A COMPLETE AND FULLY OPERATIONAL SYSTEM ACCEPTED BY THE AUTHORITY HAVING JURISDICTION. D. FIRE ALARM DEVICES SHOWN ON DRAWINGS ARE FOR ARCHITECTURAL COORDINATION ONLY. SHOULD ADDITIONAL DEVICES BE REQUIRED TO PROVIDE A CODE COMPLIANT SYSTEM TO THE SATISFACTION OF THE AUTHORITY HAVING JURISDICTION THEY SHALL BE INCLUDED WITHIN THE BID. ANY ADDITIONAL DEVICES NEEDED SHALL BE PROVIDED AND INSTALLED AT NO ADDITIONAL COST TO THE OWNER. E. SUBMITTALS TO AUTHORITIES HAVING JURISDICTION: IN ADDITION TO DISTRIBUTION REQUIREMENTS FOR SUBMITTALS SPECIFIED IN DIVISION 01 SECTION "SUBMITTALS," MAKE AN IDENTICAL SUBMITTAL TO AUTHORITIES HAVING JURISDICTION. TO FACILITATE REVIEW, INCLUDE COPIES OF ANNOTATED CONTRACT DRAWINGS AS NEEDED TO DEPICT COMPONENT LOCATIONS. RESUBMIT IF REQUIRED TO MAKE CLARIFICATIONS OR REVISIONS TO OBTAIN APPROVAL AT NO ADDITIONAL COST TO THE OWNER. ON RECEIPT OF COMMENTS FROM AUTHORITIES HAVING JURISDICTION, SUBMIT THEM TO ARCHITECT FOR REVIEW. F. PROVIDE LETTER ATTESTING TO THE SUBMITTAL OF ALL DOCUMENTS TO AUTHORITY HAVING JURISDICTION. G. APPROVAL AND ACCEPTANCE: PROVIDE THE "RECORD OF COMPLETION" FORM ACCORDING TO NFPA 72 TO OWNER, ARCHITECT, AND AUTHORITIES HAVING JURISDICTION. H. RECORD OF COMPLETION DOCUMENTS: PROVIDE THE "PERMANENT RECORDS" ACCORDING TO NFPA 72 TO OWNER, ARCHITECT AND AUTHORITIES HAVING JURISDICTION. FORMAT OF THE WRITTEN SEQUENCE OF OPERATION SHALL BE THE OPTIONAL INPUT /OUTPUT MATRIX. 6. HARD COPIES ON PAPER TO OWNER, ARCHITECT, AND AUTHORITIES HAVING JURISDICTION COPPER FEEDER SCHEDULE BRANCH CIRCUIT SCHEDULE TRANSFORMER SCHEDULE FEEDER TAG (4000.4) (4000.3) (3500.4) (3500.3) (3000.4) (3000.3) (2500.4) (2500.3) (2000.4) (2000.3) (1600.4) (1600.3) (1200.4) (1200.3) (1000.4) (1000.3) (800.4) (800.3) (700.4 ) (700.3) (600.4) (600.3) ( 500.4 ) (500.3 ) (450.4) (450.3) (400.41) (400.4) (400.3) ( 350.4 ) ( 350.3 ) ( 300.4 ) ( 300.3) CO MET NDUITS SETS RNC CONDUCTORS P ER SET GROUND PHASE /NEUTRAL NOTES FEEDER TAG CONDUITS CONDUCTORS PER SET MET SETS RNC PHASE /NEUTRAL GROUND NOTES CIRCUIT TAG CONDUITS CONDUCTORS PER SET MET SETS RNC PHASE /NEUTRAL GROUND WIRING CONFIG. NOTES 3.50" 3.00" 3.50" 3.00" 3.50" 3.00" 3.50" 3.00" 3.00" 3.00" 3.00" 3.00" 3.00" 3.00" 3.00" 3.00" 3.00" 2.50" 3.50" 3.00" 3.00" 2.50" 2.50" 2.50" 2.50" 2.00" 2.50" 2.00" 2.00" 3.50" 2.50" 3.00" 2.50" 11 11 10 10 8 8 7 7 6 6 5 5 4 4 3 3 3 3 2 2 2 2 2 2 2 2 2 2 2 1 1 1 1 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 4.00" 3.00" 4.00" 4.00" 3.00" 3.00" 4.00" 4.00" 4.00" 3.00" 3.00" 2.50" 3.00" 2.50" 2.50" 2.50" 2.50" 4.00" 4.00" 3.00" 3.00" (4) 500 KCMIL (3) (4) (3) (4) (3) (4) (3) (4) (3) (4) (3) (4) (3) (4) 400 KCMIL (3) 400 KCMIL (4) 300 KCMIL (3) 300 KCMIL (4) 500 KCMIL (3) 500 KCMIL (4) 350 KCMIL (3) 350 KCMIL (4) 250 KCMIL (3) 250 KCMIL (4) #4/0 (3) #4/0 (3) #4/0, (2) #3 /0 -N (4) #3/0 (3) 3/0 (4) 500 KCMIL (3) 500 KCMIL (4) 350 KCMIL (3) 350 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 400 400 400 400 350 350 KCMIL KCMIL KCMIL KCMIL KCMIL KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 500 KCMIL 400 KCMIL 400 KCMIL 350 KCMIL 350 KCMIL 250 KCMIL 250 KCMIL #4/0 #4/0 #3/0 #3/0 #2/0 #2/0 #1/0 #1/0 #1/0 #1/0 #1 #1 #2 #2 #2 #2 #2 #2 #2 #2 #2 #4 #4 1 (250.4 ) (250.3) (225.4) ( 225.3) (200.4) (200.3) (175.4 ) (175.3 ) (150.4 ) (150.3) (125.4) (125.3 ) (110.4K) (110.4) (110.3) (100.4) ( 100.3 ) (90.4) ( 90.3 ) (80.4) (80.3) (70.4) ( 70.3 ) (60.4) ( 60.3 ) (50.4) (50.3) (40.4) (40.3) (30.4) ( 30.3 ) (20.4) ( 20.3 ) 2.50" 2.50" 2.50" 2.00" 2.00" 2.00" 2.00" 1.50" 2.00" 1.50" 1.50" 1.25" 1.50" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.25" 1.00" 1.25" 1.00" 1.00" 0.75" 1.00" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3.00" 3.00" 3.00" 2.50" 2.50" 2.50" 2.50" 2.00" 2.00" 2.00" 1.50" 1.50" 2.00" 1.50" 1.50" 1.50" 1.50" 1.50" 1.50" 1.50" 1.50" 1.50" 1.50" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" (4) (3) (4) (3) (4) (3) (4) (3) (4) (3) (4) (3) (3) 250 KCMIL 250 KCMIL #4/0 #4/0 #3/0 #3/0 #2/0 #2/0 #1/0 #1/0 #1 #1 #2,(1) #4 /0 -N (4) #2 (3) #2 (4) #2 (3) #2 (4) #2 (3) #2 (4) #4 (3) #4 (4) #4 (3) #4 (4) #6 (3) #6 (4) #6 (3) #6 (4) #8 (3) #8 (4) #10 (3) #10 (4) #12 (3) #12 #4 #4 #4 #4 #6 #6 #6 #6 #6 #6 #6 #6 #6 #6 #6 #8 #8 #8 #8 #8 #8 #8 #8 #10 #10 #10 #10 #10 #10 #10 #10 #12 #12 ( XFR ) ( SCHD ) 1 2 3 GENERAL NOTES: A. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN /THWN INSULATION. B. PROVIDE GROUND WIRE NOTED ABOVE IN ALL FEEDERS AND BRANCH CIRCUITS. WHERE MULTIPLE CONDUITS ARE INDICATED PROVIDE NOTED GROUND WIRE IN EACH CONDUIT. C. NOT ALL FEEDERS ARE NECESSARILY USED ON THIS PROJECT. D. NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75 DEG..0 TERMINALS. E. "MET " = EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC " = PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND. REFER TO SIZING ON DRAWINGS IF "RNC" CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES NOTED ON SINGLE -LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. NOTES: 1. OVERSIZED (173% MIN.) NEUTRAL FOR FEEDERS CONNECTED TO A K -4 OR HIGHER RATED TRANSFORMER. 2. REFER TO TRANSFORMER SCHEDULE FOR STANDARD PRIMARY AND SECONDARY FEEDER SIZES. 3. REFER TO MCC OR PANEL SCHEDULES FOR FEEDER SIZES TO EQUIPMENT NOTED WITH THIS TAG. ( 60.2N) ( 60.2 ) ( 60.1 ) (50.2N) (50.2) (50.1) ( 40.2N ) (40.2) (40.1) (30.2N ) ( 30.2 ) ( 30.1 ) (20.2N ) ( 20.2 ) (20.1) 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.75" 0.50" 0.50" 0.50" 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" 1.00" (2) #6, (1) #6N (2) #6 (1) #6, (1) #6N (2) #6, (1) #6N (2) #6 (1) #6, (1) #6N (2) #8, (1) #8N (2) #8 (1) #8, (1) #8N (2) #10, (1) #10N (2) #10 (1) #10, (1) #1ON (2) #12, (1) #12N (2) #12 (1) #12, (1) #12N #10 #10 #10 #10 #10 #10 #10 #10 #10 #10 #10 #10 #12 #12 #12 10,2W,N 10,2W 10,1 W,N 10,2W,N 10,2W 10,1 W,N 10,2W, N 10,2W 10,1 W,N 10,2W,N 10,2W 10,1W,N 10,2W,N 10,2W 10,1 W,N 1,2 1,2 1,2 GENERAL NOTES: A. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER CONDUCTORS WITH THHN/THWN INSULATION. B. PROVIDE GROUND WIRE NOTED ABOVE IN ALL BRANCH CIRCUITS. C. NOT ALL BRANCH CIRCUITS SHOWN ABOVE ARE NECESSARILY USED ON THIS PROJECT. D. "MET"= EMT, IMC, GRC, RAC, OR PVC COATED GRC TYPE CONDUITS. "RNC " = PVC 40, PVC 80 OR FIBERGLASS TYPE CONDUITS ROUTED UNDERGROUND. REFER TO SIZING ON DRAWINGS IF "RNC" CONDUITS ARE ROUTED ABOVEGROUND. CONDUIT SIZES NOTED ON SINGLE -LINE DIAGRAM OR ON PLANS SUPERSEDE SIZES NOTED ABOVE IF LARGER. E. THIS SCHEDULE APPLIES TO STANDARD LENGTH CIRCUITS ONLY. CONTRACTOR TO UPSIZE WIRING AS REQUIRED TO MEET MINIMUM VOLTAGE DROP REQUIREMENTS INDICATED IN SPECIFICATIONS. GROUND CONDUCTOR WILL ALSO NEED TO BE INCREASED PROPORTIONATELY AS REQUIRED BY NEC. F. THESE BRANCH CIRCUITS TAGS ARE TYPICALLY NOT SHOWN ON PLANS FOR CLARITY REASONS. CONTRACTOR SHALL USE THIS INFORMATION AS IT APPLIES FOR ALL CONDUITS CONTAINING ONE OR MORE 20A/1P CIRCUITS. G. ALL HOMERUNS SHALL USE 0.75" CONDUIT SIZE MINIMUM. NOTES: 1. THESE BRANCH CIRCUITS TAGS ARE TYPICALLY NOT SHOWN ON PLANS FOR CLARITY REASONS. CONTRACTOR SHALL USE THIS INFORMATION AS IT APPLIES FOR ALL CONDUITS CONTAINING ONE OR MORE 20A/1P CIRCUITS. 2. CONTRACTOR MAY COMBINE 20A 1 AND 2 -POLE CIRCUITS, UP TO A MAXIMUM OF 4 PHASE CONDUCTORS, IN ONE CONDUIT. ALL 3 -PHASE AND CIRCUITS LARGER THAN 20A SHALL BE IN DEDICATED CONDUITS, UON. WHERE NEUTRALS FOR 20A CIRCUITS ARE SHARED, THE MINIMUM NEUTRAL WIRE SIZE SHALL BE #10 AWG., ONE PER "ROUNDHOUSE." E00.01 ELECTRICAL LEGEND E00.02 ELECTRICAL SCHEDULES E01.01 SITE PLAN - ELECTRICAL E02.01 LEVEL 01 CONSTRUCTION PLAN - LIGHTING E03.01 LEVEL 01 CONSTRUCTION PLAN - POWER E03.02 ROOF PLAN - POWER E05.01 ELECTRICAL RISER DIAGRAM E06.01 DETAILS - ELECTRICAL KVA 480V PRIMARY 208Y/120V SECONDARY C.B. FEEDER C.B. FEEDER GROUND AWG WT. 15 30/3 (30.3) 50/3 ( 50.4K) #8 275 30 50/3 (50.3) 100/3 (110.4K) #8 340 45 70/3 ( 70.3 ) 150/3 (150.4K) #6 475 75 125/3 (125.3) 225/3 (225.4K) #2 1060 112.5 175/3 (175.3) 400/3 (400.4K) #1/0 1250 150 225/3 (225.3) 500/3 (500.41) #2/0 2130 225 350/3 ( 350.3 ) 800/3 (800.41) #3/0 2665 300 450/3 ( 450.3) 1000/3 (1000.41 #3/0 4190 500 800/3 ( 800.3) 1600/3 (600.41 #4/0 3480 GENERAL NOTES: A. THIS SCHEDULE APPLIES TO 480V TO 208Y/120V DRY TYPE STEP -DOWN TRANSFORMERS ONLY. B. ON ONE -UNE DIAGRAMS AND SCHEDULES WHERE FEEDERS AND CIRCUIT BREAKERS ARE SHOWN AS "XFR ", PROVIDE RESPECTIVE FEEDERS, GROUND CONDUCTORS AND BREAKERS NOTED ABOVE. PROVIDE SECONDARY BREAKER NOTED ABOVE AS MAIN CIRCUIT BREAKER INTERGRAL IN DISTRIBUTION, PANEL AND SWITCH BOARDS, UON. C. DELETE "K" SUFFIX IN FEEDER DESIGNATION IF TRANSFORMER IS K -1 RATED. (STANDARD UNLESS "K" RATING IS SHOWN ON ONE -UNE DIAGRAM). D. GROUND CONDUCTOR SIZES INDICATED ABOVE SUPERSEED GROUND CONDUCTORS SHOWN ON FEEDER SCHEDULE. ROUTE COPPER GROUNDING CONDUCTOR TO GROUNDING ELECTRODE PER NEC. PROVIDE BONDING ALSO PER NEC. COMMON LEAD OF LARGEST REQUIRED SIZE MAY BE EMPLOYED TO SERVE MULTIPLE TRANSFORMERS. E. NOT ALL TRANSFORMER SIZES INDICATED IN THIS SCHEDULE ARE NECESSARILY USED ON THIS PROJECT. F. WEIGHTS INDICATED ABOVE ARE APPROXIMATE, ACTUAL VALUES MAY VARY. CONFIRM WITH SUBMITTAL INFO. G. GROUND CONDUCTOR SIZES LISTED ARE FOR COPPER CONDUCTORS. (E) (F) (R) (RL) AB ACU AC A, AMP AF AFF AFG AIC AL AT AUTO AUX AWG BG BRKR C CB CKT CLG CO CT CU DC DISC DIA DIV DWG E,EM EF EMT ENCL EWC EWH F FA FAA FBO FC FLA FLEX FPB FSD GEN GFI GND GRC HLO HP HPF HTR HZ IES IMC KCMIL KO KW KVA ABBREVIATIONS EXISTING TO REMAIN FUTURE EXISTING TO BE REMOVED EXISTING TO BE RELOCATED ABOVE COUNTER BACKSPLASH AIR CONDITIONING UNIT ALTERNATING CURRENT AMPERES AMPERE (RATED) FUSE OR CB FRAME ABOVE FINISHED FLOOR ABOVE FINISHED GRADE EQUIPMENT SHORT CIRCUIT INTERRUPT RATING (R MS SYM. AMPS) ALUMINUM (ALLOY) CIRCUIT BRKR TRIP SETTING (AMPS) AUTOMATIC AUXILIARY AMERICAN WIRE GAUGE BELOW GRADE CIRCUIT BREAKER CONDUIT (CIRCULAR. RACEWAY) CIRCUIT BREAKER CIRCUIT CEILING CONDUIT ONLY CURRENT TRANSFORMER COPPER DIRECT CURRENT DISCONNECT DIAMETER DIVISION DRAWING EMERGENCY EXHAUST FAN ELECTRICAL METALLIC TUBING ENCLOSURE ELECTRIC WATER COOLER ELECTRIC WATER HEATER FUTURE FIRE ALARM FIRE ALARM ANNUNCIATOR FURNISHED BY OTHERS FOOT CANDLES FULL LOAD AMPERES FLEXIBLE FAN POWERED BOX FIRE /SMOKE DAMPER GENERATOR GROUND FAULT CIRCUIT INTERRUPTER GROUND GALVANIZED RIGID STEEL CONDUIT HANDLE LOCK - ON(OFF) HORSEPOWER HIGH POWER FACTOR HEATER HERTZ (CYCLES PER SECOND) ILLUMINATING ENGINEERING SOCIETY INTERMEDIATE METAL CONDUIT THOUSAND CIRCULAR MILS KNOCK OUT KILOWATTS KILOVOLT- AMPERES LTG MAX MCA MFR MIN MISC MLO MTD MTR -N- NC NEC -,NEG NEMA NL NO NTS NP OC OD OS PB PH, 0 PNL +,POS REQD RNC RS RST SEC SWBD SWGR TB TEL TYP UL UON UPS UTX VA VFD W W/ W/0 WP XFR IN ', FT 0 LIGHTING MAXIMUM MINIMUM CIRCUIT AMPERES MANUFACTURER MINIMUM MISCELLANEOUS MAIN LUGS ONLY MOUNTED MOTOR NEUTRAL (GROUNDED CONDUCTOR) NORMALLY CLOSED NATIONAL ELECTRICAL CODE NEGATIVE NATIONAL ELECTRICAL MFGR'S ASSOC. NIGHT LIGHT (UNSWITCHED) NORMALLY OPEN NOT TO SCALE NAMEPLATE ON CENTER OUTSIDE DIAMETER OCCUPANCY SENSOR POLE PUSHBUTTON PHASE PANEL POSITIVE REQUIRED RIGID NON- METALLIC CONDUIT (PVC) RAPID START REMOTE STATION TRANSMITTER SECONDARY SWITCHBOARD SWITCHGEAR TERMINAL BOARD TELEPHONE TYPICAL UNDERWRITERS LAB UNLESS OTHERWISE NOTED UNINTERRUPTIBLE POWER SUPPLY UTIUTY TRANSFORMER VOLTS VOLT- AMPERES VARIABLE FREQUENCY DRIVE WATT WrrH WITHOUT WEATHERPROOF, SEE RECEPT. SYMBOL TRANSFORMER ZONE INCHES FEET PHASE RECEIVED CITY OF TUKWILA JUL 1.8 2008 PERMIT CENTER CODE CO NFPA 7( JUL City Of BUILDING Tukwila DIVISION- 1 SeallSignature SEAL OF G JAC.+ [ A. ENGIIEERING 4. �cti° 1" % `p x ,: ►4 4 rs� ■�4 ONAL ' 1 EXPIRES 08 -21 -08 1 Project Name Southcenter Branch Relocation 1 Project Number 32.2177.089 IDescription Electrical Legend Scale EOO.O1 ? 2006 Gensler Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: WA0049 NRSP VERSION: 2.0 INCLUDES BULLETIN: 21A 1524 Fifth Avenue Suite 300 Seattle, WA 98101 G ' Telephone 206.654.2101 er Facsimile 206.654.2121 Architecture, Design & Planning Worldwide GLU MAC engineers ' en ineers for a sustainable future*• L J 1325 Fourth Ave, Suite 1515 Job No.: 507023GEN Seattle, WA 98101 Contact: T. 206.262.1010 F. 206.262.9865 www.glumac.com 1 Rev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV 1 MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ ED F FOR ) -NEC,. 1 2008 Q: \_2007— Jobs \507048GEN.g2 \BOASOUTH— E00- 02.dwg 20 Jun 2008 — 1:25 pm tam INTERIOR LUMINAIRE SCHEDULE Type Description Mounting Volts Input Watts Lamps Notes A Lithonia 2GT8- 4- 32 —A19 -120 Recessed 120 115 F —F32T8 6 AE Some as type A except emergency 1 -175W Metal Halide E17 200 208 Hydrel 9100 series 9100—A-175M- 208— WWD— FLC -34B- GEB—LP 1, 5, 6 B Juno C6V -32T & C600 —CL —WH Recessed 120 40 1 —C32DT 6 BE Juno C6V- 32T —BN $ C600— CI —WH —BN Recessed 120 40 1 —C32DT 1, 5, 6 C Neoray Linear 79PFIT8- 4 -120WR Recessed 120 32 1— F032/835/ECO 6, 9 D Lithonia Finess N2S— Length as required Under Cabinet 120 32 1 —T8 Length as required 6 D1 Lithonia Finess N2S— Length as required Under Cabinet 120 17 1 —T8 Length as required 6 E Lithonia Avante 2AVG232MDR 120 GEB Recessed 120 62 2 —F32T8 6 EE Lithonia Avante 2AVG232MDR 120 GEB —EL Recessed 120 62 2 —F32T8 1, 5, 6 F Lithonia GT- 232— A12125 -120 —GEB Recessed 120 62 2 —F32T8 6 FE Lithonia GT- 232— A12125 -120— GEB —EL Recessed 120 62 2 —F32T8 1, 5, 6 H Lithonia C232- 120 —ES —WG Surface 120 62 2 —F32T8 2, 6 HE Lithonia C232 - 120— ES —WG —EL Surface 120 62 2 —F32T8 2, 6 1 Gotham AHZ -100M -8AR- 120 —TRW Recessed 120 130 1 -100w Metal Halide IE Gotham AF- 226DTT- 8AR —EL Recessed 120 62 2— F26DTT 1, 7 J Lithonia G2V- 175M— RW —T73 -120 Recessed 120 213 1 -175W Metal Halide 3, 4 K Open /Closed Sign supplied by drive —thru vendor Surface 120 N/A Supplied with fixture LE Guardco 101 EM— MT -226QF -120 Surface 120 62 2 -26DTT 1, 7, 8 M Lightolier QVS- 1— G— PF —OS- 232 - 120 —SO W /FK91 X4 Frame kit Recessed • 120 62 2— F32T8 /ECO 9 ME Lightolier QVS- 1— G— PF —OS- 232 - 120 —SO —N W /FK91 X4 Frame kit Recessed 120 62 2— F32T8 /ECO 1, 5, 9 N Mark Architectural Lighting CG 12 -4 -120 -1 T8 —EB Cove 120 32 1 —F32T8 6 P DelRay Lighting H5126.A30.1 E.AL.EM Recessed 120 26 1— F26TTT 1, 5, 6 X Emergi —Lite LXN —RC —U Recessed 120 10 Supplied with fixture 5 General Notes: 1. Approved equals will be acceptable. 2. Refer to electrical specifications for additional requirements which may not necessarily be reflected in catalog number and /or description in this schedule. 3. Fixtures in the vault, work room, break room, calling cubes and Ner room require two ballasts for bi —level control. Notes: 1. Provide fixture with integral test switch. 2. Provide fixture with wire guard. 3. Provide fixture with white flange. 4. Provide fixture with gasketed door frame. 5. Provide fixture with self contained emergency battery pack. 6. Provide fixture with 3500K lamps. 7. Provide fixture directly over front /rear door with emergency battery ballast for emergency egress lighting. 8. Provide wet location rated fixture. SITE LIGHTING LUMINAIRE SCHEDULE Type Description Lamp Input Watts Volts Manufacturer/ Catalog Number Mounting OC Flag pole Tight with LED Tamp option Fixture to mount on to top of flag pole. Refer to detail 12 Sheet A09.24 for mounting information. LED supplied with pole 200 120/ 12 The Flag Company ORN— FPB— IH- 6.5 —D -12V Flag Pole OD Metal halide in —grade luminaire with cast aluminum door and wall wash optic. UL listed for wet location. 1 -175W Metal Halide E17 200 208 Hydrel 9100 series 9100—A-175M- 208— WWD— FLC -34B- GEB—LP Flush in —grade OE Metal halide in —grade luminaire with cast aluminum door and narrow flood optics. 1 -70W E1 Metal Halide 200 208 Hydrel 9100 series 9100— A -70M- 208— NFL— FtC -34B— GEB —LP Flush in —grade OF Outdoor emergency light with integral battery back —up. UL Listed for wet locations. Brushed Nickel finish. 2 -6W Xenon 12 120 Lithonia Lighting AFN BN EXT Wall mount OG 8" Illuminated fluorescent bollard with louvers. 42" overall height. Cast aluminum construction. Color as selected by architect. UL listed for wet locations. 1— F32TTT 3500K 32 208 Lithonia Lighting KB_8 32TRT LV 208 DF Bollard General Notes: 1. Approved 2. Electrical 3. Refer to 4. Refer to equals will be acceptable. contractor shall provide computer generated point —by —point foot candle layout of proposed layout with shop drawing submittals. pole base detail this sheet electrical specifications for additional requirements which may not necessarily be reflected in catalog and /or description in the schedule. DUCTLESS SPLIT SYSTEM HEAT PUMP UNIT SCHEDULE TAG DESIGN BASIS LOCATION AREA SERVED ELECTRICAL CHARACTERISTICS ELECTRICAL CIRCUIT NOTES VOLT/ PH LOAD (MCA) MOCP STARTER FUSED DISC UNIT VOL CONTROL POWER SOURCE PTS OF CONN DIV 23 DIV 26 DIV 23 DIV 26 FCU -1.1 MITSUBISHI MSZ —A15 ATM ATM 208/1 1.34 15 X — — x CONSTANT NORMAL TWO (2) D -32=34 1,2 CU —R.1 MITSUBISHI MUZ —A15 ROOF ATM 208/1 26 40 X — — X CONSTANT NORMAL ONE (1) D -36,38 2 TEF —R.1 GREENHECK GB ROOF JC /RESTROOM /BREAKROOM 115/1 0.16 1/4 — — x — CONSTANT NORMAL ONE (1) A -15 1,2 NOTES: CONDENSATE PUMP, COORDINATE 1/8 HP 120V /1PH CONNECTION WITH DIV 26. UNIT PER MANUFACTURER'S SPECIFICATIONS. 4/29/2008 13:31 1. PROVIDE 2. INSTALL FAN SCHEDULE TAG DESIGN BASIS LOCATION AREA /SYSTEM SERVED ELECTRICAL CHARACTERISTICS ELECTRICAL CIRCUIT NOTES VOLT/ PH BHP MOTOR (HP) /W STARTER FUSED DISC UNIT VOL CONTROL POWER SOURCE PTS OF CONN DIV 23 DIV 26 DIV 23 DIV 26 REF —R.2 CANFAB ROOF RTU -R.2 — POWER EXHASUTER 208/3 — 2 VFD — — X VFD BY DIV 23 NORMAL ONE (1) A- 2022,24 1,3 REF —R.3 CANFAB ROOF RTU —R.3 — POWER EXHASUTER 208/3 — 3/4 VFD — — X VFD BY DIV 23 NORMAL ONE (1) A- 26,28,30 1,3 TEF —R.1 GREENHECK GB ROOF JC /RESTROOM /BREAKROOM 115/1 0.16 1/4 — — x — CONSTANT NORMAL ONE (1) A -15 1,2 AEF -1.1 GREENHECK GB ATM ATM ROOM 115/1 28.3 217W X — x — COMSTANT NORML ONE(1) D -40 1 NOTES: IN COMPLIANCE WITH MECHANICAL AND ELECTRICAL CODE REQUIRED WORKING CLEARANCES. MOTORIZED DAMPER. WITH ROOFTOP UNIT, SEE RTU SCHEDULE. 4/29/2008 13:19 1. INSTALL 2. PROVIDE 3. PROVIDE PACKAGED ROOFTOP AIR CONDITIONING UNIT SCHEDULE TAG DESIGN BASIS LOCATION AREA SERVED ELECTRICAL CHARACTERISTICS ELECTRICAL PANEL NOTES VOLT/ PH LOAD (MCA) MOCP STARTER FUSED DISC UNIT VOL CONTROL POWER SOURCE PTS OF CONN DIV 23 DIV 26 DIV 23 DIV 26 RTU —R.1 TRANE YHC ROOF WEST 208/3 28.3 40 X — X — CONSTANT NORMAL ONE (1) A -1,3,5 12 RTU —R.2 TRANE YCD ROOF LOBBY 208/3 55.9 60 X — X — CONSTANT NORMAL ONE (1) A- 7,9,11 1,2 RTU —R.3 TRANE YHC ROOF SOUTH 208/3 20.9 30 X — X — CONSTANT NORMAL ONE (1) A -2,4,6 1,2 RTU— R.4 TRANE YHC ROOF EAST 208/3 28.3 40 X — X — CONSTANT NORMAL ONE (1) A- 8,10,12 1,2 RTU—R.5 TRANE THC ROOF NER 208/3 20.9 30 X — X — CONSTANT NORMAL ONE (1) A- 19,2123 1,2 NOTES: IN COMPLIANCE WITH MECHANICAL AND ELECTRICAL CODE REQUIRED WORKING CLEARANCES. SMOKE DETECTORS ON THE RETURN. 1. NSTALL 2. PROVIDE ELECTRIC WATER HEATER TAG DESIGN BASIS LOCATION AREA SERVED ELEMENT WATAGE (KW) ELECTRICAL ELECTRICAL CIRCUIT NOTES VOLTAGE PHASE AMP DWH -1.1 A.O. SMITH DEL -30 JANITOR'S CLOSET RESTROOMS 2.5 208 1 12 D -39,41 CP -1 B &G PL -30 MECHANICAL ROOM 1 /8HP 120 1 D -37 REVIEWED FOR COOS COMP SEC NFPA 70 JUL 2 9 200E Otyerfulwila D ION RECEIVED CITY OF TUKWILA JUL 18 L008 PERMIT CENTER • ov • Yam fat -(X N s outhcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: NRSP VERSION: INCLUDES BULLETIN: Gensler Architecture, Design & Planning Worldwide WA0049 2.0 21A 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 GLUM AC r engineers for a sustainable future 1325 Fourth Ave, Suite 1515 Seattle, WA 98101 T. 206.262.1010 F. 206.262.9865 Job No.: 507023GEN Contact: www.glumac.com Rev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ 1Seal/Signature Q � OF QUALITY Production Dept Niel Manager Project Engineer 1Project Name EXPIRES 08 -21 -08 Southcenter Branch Relocation IProject Number 32.2177.089 IDescription Electrical Schedules Scale E00.02 ? 2006 Gensler 1:26 pm tam Q: \_ 2007 — Jobs \507048GEN.g2 \BOASOUTH— E01- 01.dwg 20 Jun 2008 2006 Washin ton State Nonresidential Ener Code Com•liance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Rew seed July 2007 Project Info Project Address BoA- Southcenter Branch Relocation Date 4/29/2008 320 Strander Blvd. For Building Department Use Tukwilla, WA 98188 Applicant Name: Glumac, Tatyana Mikeladze ApplicantAddress: 1326 4th Ave. Seattle, WA 98101 Applicant Phone: 206- 262 -8375 Project Description CENTRAL ZONE 4 New Building S Addition • Alteration • Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 4 .32.0 • No changes are being made to the lighting KITCHEN • Less than 60% of the fixtures new, installed wattage not increased. & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per fl` ** Area in f1 Allowed x Area MAIN BUILDING RETAIL BANKING 1.50 7451.0 11176.5 CENTRAL ZONE TYPE "B " / "BE" - FLUORESCENT DOWNLIGHT 90 40.0 3600.0 TELLER TYPE "C" - LINEAR FLUORESCENT 4 .32.0 128.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt 11176.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed VAULT TYPE "A"/"AE" - 2'X4' RECESSED FLUORESCENT 5 115.0 575.0 CENTRAL ZONE TYPE "B " / "BE" - FLUORESCENT DOWNLIGHT 90 40.0 3600.0 TELLER TYPE "C" - LINEAR FLUORESCENT 4 .32.0 128.0 KITCHEN TYPE "D" - UNDERCABINET 5 32.0 160.0 VAULT LOBBY TYPE "Dl" - UNDERCABINET 1 17.0 17.0 CALL CB /OFFICE TYPE "E " / "EE" - 2'X4' RECESSED FLUORESCENT 22 62.0 1364.0 TELLER TYPE •'F " / "FE" - LINEAR FLUORESCENT 3 62.0 186.0 NER ROOM TYPE "H " / "HE" - LINEAR FLUORESCENT 5 62.0 310.0 TELLER TYPE "M " / "ME" - RECESSED FLUORESCENT 13 62.0 806.0 CENTRAL ZONE TYPE "N" - COVE LIGHTING - 14 32.0 448.0 Indicate location yes (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location ___ yes 1513.6.1 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts/ 7594 Notes: 1. For proposed Fixture Description. indicate fixture type. lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture. lamp. and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only. the default table in the NREC Technical Reference Manual may also be used. For track lighting. list the greater of actual luminaire wattage or length of track multiplied by 50. or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting. note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK .... -i :, 1b,•:," 9 ,..1.1t',1::; DI r.. r- :;i5 -a Alt.,: (iii Project Address BoA- Southcenter Branch Relocation 'Date 4/29/2008 The following information is necessary to check a permit application for compliance with the lighting. motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Requirec Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations Refer to WSEC Section 1513 for controls and commissioning Compliance Option yes 1513.2 Area controls Maximum limit per switch 10. 0 • Exemption (list) yes 1513.3 Daylight zone control Schedule with type and features, indicate locations ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location (a) timer w /backup Indicate location yes (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location ___ yes 1513.6.1 (a) occup. sensors Schedule with type and locations 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability): Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT TSIGNS (Section 1514) ys _ ' 1 1514 I Max. watts 'Indicate watts for each exit sign I 1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps. ballasts, watts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) 1 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp. rpm, efficiency I I TRANSFORMERS (Section 1540) ___ - 1 1540 (Transformers 'Indicate size and efficiency 1 1 If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 200E Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Proj Addres! BoA- Southcenter Branch Relocation Date 4/29/2008 Area (ft2), perimeter (If) or # of items 320 Stranger Blvd. For Building Department Use DRIVE TRHU 270W + 90W per adc Tukwilla, WA 98188 Name: Glumac, Tatyana Mikeladze Appl. Name:1325 4th Ave. Seattle, WA 98101 Appl. Phone 206- 262 -8375 Project Description 1.25 W/ft2 ❑ Plans Included requirements. 6222.5 v New ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 1 Q Lighting Power Allowance Q Systems Analysis J 1 Building Grounds (luminaires > 100 Watts) ❑ Efficacy 60Iumens/W ❑ Controlled by motion Sensor 10. 0 • Exemption (list) 5964.0 Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per if or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Automated Teller DRIVE TRHU 270W + 90W per adc 3.0 450.0 Bldg. Facade (by perim) Canopies and Overhangs DRIVE TRHU 1.25 W/ft2 4978.0 6222.5 Grounds Walkways >10' wide FRNT OF THE BUILDING WALKWAYS 0.2 W/ft2 2134.0 426.8 Main Entry MAIN DOOR 30 W/LF ofdoorwidt 10. 0 300.0 Tradable Proposed Lighting Wattage Total Allowed Watts/ 6949.3 Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Automated Teller DRIVE TRHU 270W + 90W per adc 3.0 450.0 Bldg. Facade (by perim) Grounds Walkways <10 wide TYPE "OE" IN -GRADE 4 208. 0 832.0 Grounds Walkways >10' wide TYPE "on" BALLARDS 4 32. 0 128.0 Canopies and Overhangs TYPE •'s" 28 213.0 5964.0 Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non- Tradable Maximum Allowed Lighting Wattage Total Proposed Watts/ 6924.0 Non- Tradable Locations Description Allowed Watts per ft2 or per If Area (ft-), perimeter (If) or # of items Allowed Watts x ft` (or x If) Automated Teller DRIVE TRHU 270W + 90W per adc 3.0 450.0 Bldg. Facade (by perim) 5.0 W/If 212. 0 1060.0 2 213.0 426.0 Bldg. Facade (by perim) TYPE "OD" IN -GRADE Non - Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Automated Teller TYPE "K" - SIGN EXEMPT (1532.A) Automated Teller TYPE '•J" 2 213.0 426.0 Bldg. Facade (by perim) TYPE "OD" IN -GRADE 4 208.0 832 .0 Proposed Watts may not exceed Allowed Watts for Category TRANSFORMER PAD VAULT TOP MACHINE COMPACTED BACKFILL EXTERIOR BUILDING WALL SERVICE TRANSFORMER BY UTILITY CO. 60" a . . , G •. 4 .d PRIMARY PER UTILITY CO. REQUIREMENTS 1. J J BY CO. CT'S .4. METER SOCKET PER UTILITY CO. REQUIREMENTS MOUNTED ON EXTERIOR BUILDING WALL 1 1/2"CO L� L 12" MIN. SAND, ALL AROUND 95% COMPACTED. NOTES: COMPLY WITH UTILITY COMPANY REQUIREMENTS FOR TRANSFORMER VAULT INSTALLATIONS. 2. SEE SITE PLAN FOR PRIMARY AND SECONDARY ARRANGEMENTS. 3. NON- SHRINK WATER PROOF GROUT SOLID BETWEEN KNOCK OUTS AND CONDUITS TO MINIMUM 2" THICKNESS. 4. LEAVE GROUNDING RING LEADS AND GROUNDING GUARD WIRE TAILS IN VAULT AS DIRECTED BY UTILITY COMPANY. SECONDARY TO MAIN DISTRIBUTION SWITCH BOARD PAD MOUNTED TRANSFORMER DETAIL SCALE: NO SCALE /I--1\/ 0 SDCB 403 K) -SDCB 405 tS (219 218 _P 04 ■ -c- ) SDCB 375 • ■ ■ 164-61-07 GENERAL NOTES 1. CONTRACTOR PROPOSING TO UNDERTAKE WORK UNDER THIS DIVISION SHALL VISIT THE SITE OF THE WORK AND FULLY INFORM THEMSELVES OF ALL CONDITIONS THAT EFFECT THE WORK AND COST THEREOF, AND EXAMINE THE DRAWINGS AND SPECIFICATIONS AS RELATED TO THE SITE CONDITIONS. 2. CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING EXACT LOCATIONS OF ALL LIGHTING FIXTURES BY COORDINATION WITH THE ARCHITECTURAL REFLECTED CEILING PLAN. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR CONFIRMING ALL CEILING TYPES BEFORE ORDERING LIGHTING FIXTURES. 4. CONSIDERATION WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDINGS OF THE AMOUNT OF WORK TO BE PERFORMED. TENDER OF PROPOSAL SHALL CONVEY FULL AGREEMENT TO THE ITEMS AND CONDITIONS INDICATED ON THE DRAWINGS. SHOULD THE CONTRACTOR FIND DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS OR BE IN DOUBT AS TO THE INTENT THEREOF, HE SHALL IMMEDIATELY OBTAIN CLARIFICATIONS FROM ENGINEER AND /OR OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING HIS PROPOSAL FOR WORK. 5. CONTRACTOR SHALL FIELD VERIFY EXACT NAMEPLATE DATA ON ALL EQUIPMENT FINISHED UNDER OTHER DIVISIONS AND /OR BY THE TENANT (I.E. HVAC, KITCHEN, COMPUTER EQUIPMENT, ETC.) PRIOR TO THE INSTALLATION OF ELECTRICAL WORK AND MAKE ANY ADJUSTMENTS TO OUTLETS, CONDUITS, WIRE AND /OR CIRCUIT BREAKERS AS REQUESTED TO MATCH EQUIPMENT ACTUALLY FURNISHED. 6. REFER TO ELECTRICAL RISER DIAGRAM ON SHEET E05 -05 FOR MORE INFORMATION. 7. REFER TO SPECIFICATIONS SECTION 16110 FOR UNDERGROUND CONDUIT REQUIREMENTS. 8. ALL UNDERGROUND WIRING SHALL BE LOCATED WITHIN 12" OF BACK OF CURB IN ALL LOCATIONS. SHEET NOTES 1. REFER TO CIVIL PLANS FOR LOCATION OF UTILITY COMPANY'S PAD MOUNTED TRANSFORMER AND METERING EQUIPMENT. PROVIDE CONCRETE PAD FOR UTILITY TRANSFORMER. FIELD VERIFY EXACT LOCATION OF EQUIPMENT WITH UTILITY COMPANY. CONTACTOR SHALL FIELD COORDINATE ALL ASPECTS OS SERVICE ENTRANCE WITH UTILITY COMPANY. 2. INCOMING UNDERGROUND ELECTRICAL SERVICE. REFER TO ELECTRICAL RISER DIAGRAM ON SHEET E06.01 FOR ADDITIONAL INFORMATION. 3. INCOMING UNDERGROUND TELEPHONE SERVICE CONDUIT. INSTALL (2) 4 "C. FROM TELEPHONE EQUIPMENT BACKBOARD TO PROPERTY LINE AS INDICATED. FIELD VERIFY LOCATION OF TERMINATION WITH TELEPHONE COMPANY REPRESENTATIVE. PROVIDE NYLON PULL WIRE AS DIRECTED BY TELEPHONE COMPANY. 4. REFER TO DRAWING E03.01 FOR EXACT LOCATION OF CONDUITS STUB -UP. ) )i AREA 1: 15,000 SF ■ ■ • • • REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUL 2 9 2008 City Of Tukwila B ILDING DM ION ,( V AREA 2: 32,693 SF • ■ • ■ .HARDSCAPE d o ) A-NO A INO dO1S dOIS 11011 �1U11 RN II 11U11 Ell !1U11 111111 �1U11 -1MI) P P i1�11 P 1111 *11 DIM �f�ll ROII LANDSCAPE CB 401 N N CT' CABINET AND METER �d -d P 0 P , - P 0 mi r p p. p- p--- P-P - P-v P-P P- P-P P -P---. - - - - - V SS SS ss SDCB 502 PLAN - ELECTRICAL SCALE: 11"=30'-0* SDCB 500 I I I •111111•• 1 1 1 1 1 1 1 MERE 1 1 1 I•MIIENIMI• ■III 0 15' 30' -s -SS -99 RECEIVED CITY OF TUKWILA JUL 182008 PERMIT CENTER 60' 99- eft n 41k 9 6.M.'1 Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: WA0049 NRSP VERSION: 2.0 INCLUDES BULLETIN: 21A Gensler Architecture, Design & Planning Worldwide 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 G„LUmAC r engineers for a sustainable future- 1325 Fourth Ave, Suite 1515 Seattle, WA 98101 T. 206.262.1010 F. 206.262.9865 Job No.: 507023GEN Contact: www.glumac.com L J 1 Rev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ 1 Seal /Signature SEAL OF q ENfG QUALITY Prooduccttion Dept 1 Project Name Pile Plojad Engineer EXPIRES 08 -21 -08 Southcenter Branch Relocation Project Number 32.2177.089 1 Description Site Plan - Electrical 'Scale E01.01 ? 2006 Gensler 1 :26 pm tam Q: \_ 2007 — Jobs\ 507048GEN .g2 \80ASOUTH— E02- 01.dwg 20 Jun 2008 4. 3.3 12 llmTIT11III n Ernn mrEml 1 nil 111 I-fin ETfhT11111iif -1 B BE C -112 C-12 .C-12 DAYLIGHT ZONE C -10 B 0 C -10 - -8_ C -lo 0 N C -10 C -1 C -10 CD I -Lllllu u1111L� l_lll;ll_1 1 U1111111 11 I 1 mi & 1111 1 L_11111111.11.1.11 OD 0 C -31 VA LT nni IDnNI OD 0 C -31 fnPRinnR OD 0 C -31 LEVEL 01 CONSTRUCTION PLAN - LIGHTING SCALE: 1 /4 " =1' -0" 1 1 1 •• 1 1 1 1 1 1 1 ■■■■ 111 ■ ■■■ ■■■■ 0 2' 4' 8' MEANS OF EGRESS ILLUMINATION IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. IBC 1006.2 Illumination level. The means of egress illumination level shall not be Tess than 1 foot - candle at the walking level. IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways.. 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... GENERAL NOTES 1. IF NOT INDICATED TICK MARKS ON A BRANCH CIRCUIT ARE (1) HOT (FOR SWITCH LEG), (1) NEUTRAL AND (1) GROUND WIRE. 2. CONTRACTOR SHALL PROVIDE M STOCK OF P.L. LAMPS FOR TENANTS USE, NOT LESS THAT 10% OF TOTAL LAMPS. SHEET NOTES 1. CONTRACTOR TO ROUTE CIRCUIT THRU LIGHTING CONTROL PANLE LCP. NOTE HOMERUNS WITH UNSWITCHED HOTLEG FOR EMERGENCY AND NIGHT LIGHTS. FOR CONTROL SCHEDULE AND DETAILS SEE SHEET E06.01 2. WATTSTOPPER LIGHTING INTEGRATOR LIGHTING CONTROL PANEL LI- 24 -S3R -347. FOR DETAILS SEE LOW VOLTAGE ONE -LINE DIAGRAM ON SHEET E06.01 3. NOT USED. 4. EMERGENCY LIGHTING FIXTURE SHALL BE SWITCHED. CONTRACTOR TO WIRE BATTERY CHARGING CIRCUIT OF EMERGENCY BALLAST AHEAD OF LIGHTING CONTACTOR. 5. DRIVE -THRU LIGHT SWITCHES AND COVERPLATES PROVIDED BY DRIVE -THRU EQUIPMENT SUPPLIER. INSTALLATION AND WIRING IS BY ELECTRICAL CONTACTOR. 6. WATTSTOPPER 120 VOLT PW -200 WALL SWITCH OCCUPANCY SENSOR. 7. EMERGENCY AND NIGHT LIGHT FIXTURE. CONTRACTOR TO CONNECT 24 HOUR (UNSWITCHED) CIRCUIT AHEAD OF LIGHTING CONTRACTOR. 8. PROVIDE 120V POWER TO THE POWER PACK FROM NEAREST GENERAL USE RECEPTACLE. 9. PROVIDE WATTSTOPPER UT -300 CEILING MOUNT OCCUPANCY SENSOR, UW- 100 -24 WALL SWITCH OCCUPANCY SENSOR AND (ONE)BZ -100 POWER PACK. FOR DETAILS SEE LOW VOLTAGE ONE -UNE DIAGRAM ON SHEET E06.01 10. WATTSTOPPER DATALINE LOW VOLTAGE SWITCH HDLS2SS. FOR DETAILS SEE LOW VOLTAGE ONE -LINE DIAGRAM ON SHEET E06.01 11. PROVIDE FIXTURES IN THIS AREA WITH BY -LEVEL SWITCHING. PROVIDE TWO BALLASTS IN EACH FIXTURE WITH EACH BALLAST POWERING HALF OF THE LAMPS. CIRCUIT ONE BALLAST IN EACH FIXTURE THRU THE OTHER SWITCH. 12. MOUNT LIGHT FIXTURE UNDERNEATH CABINET. 13. 24 HOUR NIGHT LIGHT FIXTURE SHALL BE UN- SWITCHED. CONTRACTOR TO WIRE FIXTURE AHEAD OF LIGHTING CONTACTOR. 14. SURFACE MOUNT LIGHT FIXTURE CENTERED ON THE WALL 8" ABOVE THE DOOR FRAME 15. WATTSTOPPER DATALINE LOW VOLTAGE SWITCH HDLS4SS. FOR DETAILS SEE LOW VOLTAGE ONE -LINE DIAGRAM ON SHEET E06.01 16. WATTSTOPPER 120 VOLT PW -100 WALL SWITCH OCCUPANCY SENSOR. 17. WATTSTOPPER 120 VOLT DW -200 WALL SWITCH OCCUPANCY SENSOR. 18. WATTSTOPPER MULTI - BUTTON LOW VOLTAGE SWITCH L3S. FOR DETAILS SEE LOW VOLTAGE ONE -LINE DIAGRAM ON SHEET E06.01 19. WATTSTOPPER CEILING MOUNTED OCCUPANCY SENSOR DT -300. FOR DETAILS SEE LOW VOLTAGE ONE -LINE DIAGRAM ON SHEET E06.01 20. WATTSTOPPER POWER PACK LC -100. FOR DETAILS SEE LOW VOLTAGE ONE -LINE DIAGRAM ON SHEET E06.01 10( lois REVIEWED FOR CODE COMUpNCE NRA 70 " NEC JUL 2 9 .2.008 • City 43f Tukwila B ILDING DM Ii N OG 0 C -33 OG C -33 OG 0 C -33 OG 0 COORDINATE EXACT LOCATI WITH AN ARCHITECT N MERCHA \IT ILLUMINATED FLAGPOLE 0 C -27 nu-annar-w-v-ir-r-n rrmun. rr,r,mnm mm-1 CONSTRUCTION PLAN - PARTIAL EXTERIOR LIGHTING SCALE: 1/8"=1'-0" I i i ■■■■ 1 1 1 1 1 1 1 MN NM 111 ■■■■■ ■■■ 0 4' 8' RECEIVED CITY OF TUKWILA JUL 1`8 2008 PERMIT CENTER 16' Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: NRSP VERSION: INCLUDES BULLETIN: Gensler Architecture, Design & Planning Worldwide WA0049 2.0 21A 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 G LUMAC 9 en ineers for a sustainable future- 1325 Fourth Ave, Suite 1515 Seattle, WA 98101 T. 206.262.1010 F. 206.262.9865 Job No.: 507023GEN Contact: www.glumac.com L J Rev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ 1Seal/Signature Pled ManVer IProject Name !EXPIRES 08 -21 -08 Southcenter Branch Relocation IProject Number 32.2177.089 1Description Level 01 Construction Plan - Lighting 1 Scale E02.01 ? 2006 Gensler 1 1 1 1 1 1 1 1 1 1 1 L6 5 4.7; 4J 3.3) • 3 Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: WA0049 NRSP VERSION: 2.0 INCLUDES BULLETIN: 21A Gensler 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 Architecture, Design & Planning Worldwide C .iiI_UMAC ' engineers for a sustainable future- 1325 Fourth Ave, Suite 1515 Job No.: 507023GEN Seattle, WA 98101 Contact T. 206.262.1010 F. 206262.9865 www.glumac.com IRev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ 1 v /TWO GANG CAST FD BOX WITH TWO �THREADED HUBS ON ONE SIDE AND FLUSH THREADED 3/4" OPENINGS ON THE OTHER SIDE. PROVIDE GFCI DUPLEX RECEPTACLE. FURNISH WITH WEATHERPROOF COVER. THAT MAINTAINS WET LABEL RATING WITH CORD & PLUG INSERTED. T &B, TAYMAC OR EQUAL. ERICSON COUPLING. ARCHITECT APPROVED ROOF FLASHING AT CONDUIT PENETRATIONS Seal /Signature Q: \_ 2007 — Jobs \507048GEN.g2 \BOASOUTH— E03- 02.dwg 20 Jun 2008 — 1:39 pm tam SUPPORT CONDUITS TO STRUCTURE DtP 08 -21 -08 3/4" RIGID STEEL CONDUIT THRU ROOF. IProject Name Southcenter Branch Relocation IProject Number 32.2177.089 111 1 11 L_I__I I UI I I I 111111LIllll111 I I i L_Ll1111111111 IW111111I L_tttl u ullILU11W 1II I I I I1ll I I I I II II I �F� ROOF MOUNTED RECEPTACLE SCALE: NONE IScale ROOF PLAN - POWER SCALE: 1/4"=1'-0* E03.02 111 •NMI 11111/11 �UM 1 1 1 . ERN • ■•■ 0 2' 4' 8' ? 2006 Gensler Q: \_ 2007 — Jobs \507048GEN.g2 \BOASOUTH— E05- 01.dwg 20 Jun 2008 — 1:26 pm tam 0:\. 2007 - Jobs\ 507048GEN .g2 \BOASOUTH- E05- O1.dwg 20 Jun 2008 - 1:26 pm tom 0:\ X007- Joba\ 507D48GEN .g2 \BOASOUtH- ED5- 01.dwg 20 Jun 2008 - 126 pm tom LOCATION: NER ROOM - NORMAL POWER P5 Gtimac2005 PANEL A LOCATION: ENTER LOCATION - NER - NORMAL POWER ®G c2005 PANEL B POLE NO. LOAD SERVED CKT SIZE LOAD C.B. PH C.B. LOAD CKT SIZE LOAD SERVED POLE NO. POLE NO. LOAD SERVED CKT SIZE LOAD C.B. PH C.B. LOAD CKT SIZE LOAD SERVED POLE NO. TYPE HP KVA AMP POL AMP POL TYPE HP KVA TYPE HP KVA AMP POL AMP POL TYPE HP KVA 1 RTU -R.1 50.3M M - 3.4 40 3 A 30 3 M 5 2.5 30.3M RTU -R.3 2 1 RECEPT - TELLER LINE 20.1 N - 1.4 20 1 A 20 1 N 7 1.4 20.1 RECEPT - TELLER LINE 2 3 20 1 M 20 3.4 L - B 20.1 LIGHITNG - TELLER M 9 2.5 20.1 N 4 3 RECEPT - TELLER LINE 20.1 N - 1.4 20 1 B 20 1 N 11 1.4 20.1 RECEPT - TELLER LINE 4 5 20 1 M 20 3.4 L 1 C 20.1 LIGHTING - EXTERIOR M 13 2.5 20.1 11 II 6 5 RECEPT - FLOOR 20.1 R 20 .4 20 1 C 20 1 N - 1.4 20.1 RECEPT - TELLER LINE 6 7 RTU -R.2 60.3M M - 6.7 60 3 A 40 3 M - 3.4 40.3M RTU -R.4 8 7 RECEPT - FLOOR 20.1 N 20 .4 20 1 A 20 1 N - .2 20.1 CASH MACHINE 8 9 20 1 M 20 6.7 - 1 B - SPARE BREAKER M 21 3.4 20.1 R 10 9 RECEPT - FLOOR 20.1 N 20 .4 20 1 B 20 1 N 23 .5 20.1 RECEPT - OFFICE (D) 10 11 20 1 M 20 6.7 - - C - SPARE BREAKER M 25 3.4 20.1 N 12 11 RECEPT - FLOOR 20.1 N - .4 20 1 C 20 1 N - .4 20.1 RECEPT - OFFICE (D) 12 13 FACP 20.1 N 20 .5 20 1 A 20 1 - 29 LIGHITNG - SITE - SPARE BREAKER 14 13 RECEPT - OFFICE 20.1 N 20 .7 20 1 A 20 - 1 N - .2 20.1 HAND KEY READER 14 15 TEF -R.1 20.1 M .3 .7 20 1 B 40 1 - 33 - - SPARE BREAKER 16 15 RECEPT - OFFICE 20.1 N 20 .7 20 1 B 20 1 N 35 .5 20.1 ATM 16 17 SPARE BREAKER - - 20 - 20 1 C - - - 37 ! RECEPT - JIC - BUSED SPACE 18 17 RECEPT - OFFICE 20.1 N - .9 20 1 C 20 1 R - .7 20.1 RECEPT 18 19 RTU -R.5 30.3M M - 2.5 30 3 A 20 3 M 2 .9 20.3M REF -R.2 20 19 MONITORS 20.1 N 20 1 20 1 A 20 1 R - .7 20.1 RECEPT 20 21 " " PH AMPS A 40.0 B 40.0 C 20.8 80% RATED PNL DMND FACTORS M - - - - -> - - - -> MOTOR ---> > 2.5 -> - -> - - -> --> SPARE -> 12 14 38 15 17 48 B FED FROM: PANEL A M .9 22 21 RECEPT - ROOF TOP 20.1 N .4 20 1 B 20 1 R .7 20.1 RECEPT 22 23 " " M 2.5 C M .9 24 23 RECEPT - WORK ROOM 20.1 N - .7 20 1 C 20 1 N .7 20.1 RECEPT - WORK STATIONS 24 25 SPARE BREAKER - - 20 1 A 20 3 M .8 .4 20.3M REF -R.3 26 25 RECEPT - WORK COUNTER 20.1 N .2 20 1 A 20 1 N - .4 20.1 RECEPT - WORK STATIONS 26 27 SPARE BREAKER - - - - 20 1 B M .4 II II 28 27 RECEPT - WORK COUNTER 20.1 R .2 20 1 B 20 1 N .7 20.1 RECEPT - WORK STATIONS 28 29 SPARE BREAKER 20 1 C M .4 30 29 RECEPT - BREAK ROOM 20.1 N - .4 20 1 C 20 1 N - .5 20.1 ATM 30 31 SURGE SUPPRESSION 60.4 N - - 60 3 A 100 3 SF - 7.8 1 LINE PANEL B 32 31 RECEPT - BREAK ROOM 20.1 N - .4 20 1 A 20 1 N - .2 20.1 RECEPT - WORK COUNTER 32 33 N B SF 8.2 IS II 34 33 RECEPT - BREAK ROOM 20.1 N .4 20 1 B 20 1 N .2 20.1 RECEPT - WORK COUNTER 34 35 N - C SF 7.7 36 35 RECEPT - BREAK ROOM 20.1 N .3 20 1 C 20 1 N - .2 20.1 RECEPT - WORK COUNTER 36 37 PANEL D 1 LINE SF 11.4 225 3 A 225 3 SF - 4.8 1 LINE PANEL C 38 37 RECEPT - WORK COUNTER 20.1 N - .4 20 1 A 20 1 N .2 20.1 RECEPT - WORK COUNTER 38 39 SF 10.2 B SF 4.8 11 11 40 39 RECEPT - WORK COUNTER 20.1 N .4 20 1 B 20 1 N .3 20.1 WATER COOLER 40 41 SF 11.4 C SF 2.5 II VI 42 41 RECEPT - WORK COUNTER 20.1 N .4 20 1 C 20 1 N .3 20.1 WATER COOLER 42 VOLTAGE: 120Y/208V 30, 4W MOUNTING: SURFACE MAIN: 600A MCB BUS RATING 600A AIC RATING: SEE ONE LINE CONN. DEMAND DEMAND LOAD TYPE KVA FACTOR KVA AMPS CONN LOAD SUMMARY CIRCUIT NOTES: VOLTAGE: 120Y/208V 30, 4W MOUNTING: SURFACE MAIN: 100A MLO BUS RATING 100A AIC RATING: SEE ONE LINE CONN. DEMAND DEMAND LOAD TYPE KVA FACTOR KVA AMPS CONN LOAD SUMMARY CIRCUIT NOTES: LIGHTING 6.6 NEC 220 8.3 22.9 PH AMPS A 369.2 B 364.2 C 345.0 80% RATED PNL DMND FACTORS LIGHTING > 0 NEC 220 0 0 PH AMPS A 65.0 B 68.3 C 64.2 80% RATED PNL DMND FACTORS (L) -> -11 (R) RECEPTACLES - - - - -> 4.6 NEC 220 -13 4.6 12.8 (M) MOTOR LOADS - - - -> 66.5 1.0 66.5 184.7 LARGEST MOTOR - - -> 2.7 0.25 .7 1.9 (C) CONTINUOUS - - - -> 0 1.25 0 0 (N) NON - CONTINUOUS -> 51.7 1.0 51.7 143.6 (K) KITCHEN EQUIP. - - -> 0 1.0 0 0 (. #) SPECIAL DEMAND - - -> 0 1.0 0 0 (L) -11 (R) RECEPTACLES - - - - -> 2.7 NEC 220 -13 2.7 7.5 (M) MOTOR LOADS - - - -> 0 1.0 0 0 LARGEST MOTOR - - -> 0 0.25 0 0 (C) CONTINUOUS - - - -> 0 1.25 0 0 (N) NON - CONTINUOUS -> 21 1.0 21 58.3 (K) KITCHEN EQUIP. - - -> 0 1.0 0 0 (. #) SPECIAL DEMAND - - -> 0 1.0 0 0 ADDITIONAL PANEL FEATURES: HINGED DOOR TRIM ADDITIONAL PANEL FEATURES: HINGED DOOR TRIM 1. PANELL SHALL BE SERVICE ENTRACE RATED 2. PROVIDE FULL SIZE GROUND BUS SIZED FOR SERVICE TOTAL - ---- -> 129 132 366 WITH 25% SPARE --> 162 165 458 TOTAL - -> 24 24 66 WITH 25% SPARE --> 30 30 82 PROJECT: BOA- SOUTHCENTER BRANCH RELOC ISSUED FOR: 50% CD DATE ISSUED: 25- MAR -2008 PROJECT: BOA - SOUTHCENTER BRANCH RELOC. ISSUED FOR: 50% CD DATE ISSUED: 25- MAR -2008 FED FROM: FED FROM: PANEL A UPDATED: 41292008 5:58 pm \_2007- Jobs\ 507048GEN.g2 \BOASOUTH- E05-01.dwg 20 Jun 2008 - 126 pm tom SF = LOADS FROM SUBFED PANEUMCC XFR = SIZE PER XFR SCHD LOCATION: ELECTRICAL ROOM - NORMAL POWER CGAarec200.5 PANEL C POLE NO. LOAD SERVED CKT SIZE LOAD C.B. PH C.B. LOAD CKT SIZE LOAD SERVED POLE NO. TYPE HP KVA AMP POL AMP POL TYPE HP KVA 1 SPARE BREAKER - - - - 20 1 A 20 1 L 1 .7 20.1 LIGHITNG - CALL CUBE 2 3 RECEPT 20.1 R 2 .2 20 1 B 20 1 L 1 .8 20.1 LIGHTING - MERCHANT VEST. 4 5 SPARE BREAKER N - - - 20 1 C 20 1 L 1 1.1 20.1 LIGHITNG - CORR/REST /OFFICE 6 7 DATA RACK 20.1 N 1.5 .4 20 1 A 20 1 L - 1.4 20.1 LIGHITNG - TELLER 8 9 DATA RACK 20.1 N - .4 20 1 B 20 1 L 1 1.5 20.1 LIGHTING - CENTRAL ZONE 10 11 SPARE BREAKER - - - - 20 1 C 20 1 L 1 20.1 20.1 LIGHTING - EXTERIOR 12 13 MONITORS /NIGHT DEP 20.1 N .4 .6 20 1 A 20 1 L - 20.1 20.1 LIGHTING - EXTERIOR 14 15 TELEVISION 20.1 N - .2 20 1 B 20 1 L - .6 20.1 LIGHTING - DRIVE THRU SIGN 16 17 NER - TELEPHONE EQUIPMENT 20.1 N .2 .4 20 1 C 20 1 L - .2 20.1 LIGHITNG - EXTERIOR SOFFIT 18 19 NER - SECURITY EQUIPMENT 20.1 N .4 .7 20 1 A 20 1 - 1 20.1 - SPARE BREAKER 20 21 RRECEPT - CALLING CUBE 20.1 R - .7 20 1 B 20 1 - 1 20.1 - SPARE BREAKER 22 23 RECEPT 20.1 R 1.2 .5 20 1 C 20 1 - - - - SPARE BREAKER 24 25 DYE PACKS 20.1 N .5 .1 20 1 A 20 1 - - - RECEPT - NER ROM 26 27 LIGHITNG - FLAG POLE 20.1 L - .2 20 1 B 20 1 - SPARE BREAKER SPARE BREAKER 28 29 LIGHITNG - SITE 20.1 L - .1 20 1 C 20 1 - - - SPARE BREAKER 30 31 RECEPT - CALLING CUBE 30.1 N - .2 30 1 A 20 1 - .4 20.2M FCU -1.1 & CP SPARE BREAKER 32 33 RECEPT - CALLING CUBE 20.1 N - .2 20 1 B 20 1 - .4 SPARE BREAKER 34 35 RECEPT - CALLING CUBE 30.1 N .3 .2 30 1 C 20 1 - 2.7 - CU -R.1 SPARE BREAKER 36 37 ! RECEPT - JIC 20.1 N .5 .7 20 1 A 20 1 - - - - SPARE BREAKER 38 39 i SPARE BREAKER N - - - 20 1 B 20 1 - - - AEF -1.1 SPARE BREAKER 40 41 ; SPARE BREAKER N - - 20 1 C 20 1 - .5 20.1 RECEPT - BREAKROOM SPARE BREAKER 42 VOLTAGE: 120Y/208V 30, 4W MOUNTING: SURFACE MAIN: 225A MLO BUS RATING 225A AIC RATING: SEE ONE LINE CONN. DEMAND DEMAND LOAD TYPE KVA FACTOR KVA AMPS CONN LOAD SUMMARY CIRCUIT NOTES: (L) LIGHTING (R) RECEPTACLES (M) MOTOR LARGEST (C) CONTINUOUS (N) NON (K) KITCHEN (. #) SPECIAL TOTAL WITH > 6.6 NEC 220 -11 8.3 22.9 1.4 NEC 220 -13 1.4 3.9 0 1.0 0 0 0 0.25 0 0 0 1.25 0 0 4.1 1.0 4.1 11.4 0 1.0 0 0 0 1.0 0 0 PH AMPS A 40.0 B 40.0 C 20.8 80% RATED PNL DMND FACTORS LOADS - CONTINUOUS EQUIP. DEMAND - 25% - - - - -> - - - -> MOTOR ---> > ADDITIONAL PANEL FEATURES: HINGED DOOR TRIM -> - -> - - -> --> SPARE -> 12 14 38 15 17 48 PROJECT: BOA - SOUTHCENTER BRANCH RELOC. c ISSUED FOR: 50% CD DATE ISSUED: 25- MAR -2008 FED FROM: PANEL A UPDATED: 4/282008 5:48 pm SF = LOADS FROM SUBFED PANEUMCC XFR = SIZE PER XFR SCHD PNL D 14K AIC PNL C 14K AIC PNL B 14K AIC (225.4) (225.4) (100.4) I L ELECTRICAL RISER DIAGRAM SCALE: NOT TO SCALE CT CABINET UPDATED: 3127200811:08 am SF = LOADS FROM SUBFED PANEUMCC XFR = SIZE PER XFR SCHD 0:\_2007- Jobs\ 507048GEN .q2 \BOASOUTH- E05- 01.duq 20 Jun 2008 - 126 pm tam LOCATION: NER ROOM - NORMAL POWER GGAsree2005 PANEL D POLE NO. LOAD SERVED CKT SIZE LOAD C.B. PH C.B. LOAD CKT SIZE LOAD SERVED POLE NO. TYPE HP KVA AMP POL AMP POLJTYPE HP KVA 1 ATM 20.1 N 2 20 1 A 20 1 N 1 20.1 DRIVE THRU EQUIPMENT 2 3 ATM 20.1 N 2 20 1 B 20 1 N - 1 20.1 DRIVE THRU EQUIPMENT 4 5 ATM TOPPER 20.1 N 1 20 1 C 20 1 N - 1 20.1 DRIVE THRU EQUIPMENT 6 7 VAT BLOWER 20.1 N 1.5 20 1 A 20 1 N - 1 20.1 DRIVE THRU EQUIPMENT 8 9 VAT BLOWER 20.1 N - 1.5 20 1 B 20 1 N 1 20.1 DRIVE THRU EQUIPMENT 10 11 VAT BLOWER 20.1 N - 1.5 20 1 C 20 1 N 1 20.1 DRIVE THRU EQUIPMENT 12 13 SECURITY EQP (ISO GND) 20.1 N .4 20 1 A 20 1 N - 1 20.1 DRIVE THRU EQUIPMENT 14 15 SECURITY EQP (ISO GND) 20.1 N .4 20 1 B 20 1 N - 1 20.1 DRIVE THRU EQUIPMENT 16 17 DOOR HARDWARE 20.1 N - .2 20 1 C 20 1 N 1 20.1 DRIVE THRU EQUIPMENT 18 19 RECEPT - ATM 20.1 N - .4 20 1 A 20 1 N 1 20.1 DRIVE THRU EQUIPMENT 20 21 RECEPT - OFFICE 20.1 N .4 20 1 B 20 1 N 1 20.1 DRIVE THRU EQUIPMENT 22 23 RECEPT - OFFICE 20.1 N 1.2 20 1 C 20 1 - SPARE BREAKER 24 25 RECEPT- ROOF 20.1 R .5 20 1 A 20 1 - - SPARE BREAKER 26 27 SPARE BREAKER - - 20 1 B 20 1 - - SPARE BREAKER 28 29 SPARE BREAKER - - 20 1 C 20 1 - - SPARE BREAKER 30 31 SPARE BREAKER - - - 20 1 A 20 2 M .2 .4 20.2M FCU -1.1 & CP 32 33 SPARE BREAKER - - 20 1 B M .4 34 35 EWC -1 20.1 N - .3 20 1 C 40 2 M 2.7 40.2M CU -R.1 36 37 CP -1 20.1 M .2 .5 20 1 A M 2.7 38 39 DWH -1.1 20.2N N - 1.3 20 2 B 20 1 M - .2 20.1 AEF -1.1 40 41 " " N 1.3 C 20 1 R - .5 20.1 RECEPT - BREAKROOM 42 VOLTAGE: 120Y/208V 30 4W MOUNTING: SURFACE MAIN: 225A MLO BUS RATING 225A AIC RATING: SEE ONE LINE CONN. DEMAND DEMAND LOAD TYPE KVA FACTOR KVA AMPS CONN LOAD SUMMARY CIRCUIT NOTES: (L) LIGHTING (R) RECEPTACLES (M) MOTOR LARGEST (C) CONTINUOUS (N) NON (K) KITCHEN (. #) SPECIAL TOTAL WITH > 0 NEC 220 -11 0 0 1 NEC 220 -13 1 2.8 6.9 1.0 6.9 19.2 .5 0.25 .1 .3 0 1.25 0 0 26.4 1.0 26.4 73.3 0 1.0 0 0 0 1.0 0 0 PH AMPS A 103.3 B 85.0 C 97.5 80% RATED PNL DMND FACTORS LOADS - CONTINUOUS EQUIP. DEMAND - 25% - - - -> - - - -> MOTOR - - -> > ADDITIONAL PANEL FEATURES: HINGED DOOR TRIM _____.> SPARE -> - -> - - -> 34 34 96 -> 43 43 119 PROJECT: BOA - SOUTHCENTER BRANCH RELOC. u ISSUED FOR: 50% CD DATE ISSUED: 25- MAR -2008 FED FROM: PANEL A Pm 225 KVA PAD MOUNTED 120/208V SF = LOADS FROM SUBFED PANEUMCC XFR = SIZE PER XFR SCHD GENERAL NOTES 1. ALL CIRCUITS ARE 3 PHASE, UNLESS OTHERWISE NOTED. 2. REFER TO DWG. E00.01 FOR LEGEND FOR TRANSFORMER AND FEEDER SIZES. 3. REFER TO DWG. E03.01 FOR GROUNDING DETAILS. 4. ITEMS SHOWN WITH THIN DASH -DOT OR DASHED LINES ARE EXISTING. ITEMS SHOWN WITH SHADED SHORT- DASHED LINES ARE, FUTURE. 6. THE VALUE IN THE WIDE HEXAGON IS THE AVAILABLE INTERRUPTING SHORT- CIRCUIT CURRENT (AIC) AT THAT PIECE OF EQUIPMENT. REVIEWED MPLIFANCE CODE COMPLIANCE JUL 2 9 2008 City Of likwila N DM ION B ILD 0 -o [cb RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER d erica Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: NRSP VERSION: INCLUDES BULLETIN: Gensler Architecture, Design & Planning Worldwide WA0049 2.0 21A 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 GLUMAC r engineers for a sustainable future- 1325 Fourth Ave, Suite 1515 Seattle, WA 98101 T. 206.262.1010 F. 206.262.9865 Job No.: 507023GEN Contact: www.glumac.com L .1 Rev Issue Date & Issue Description By Check 02/13/2008 Design Development MA I TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ SeallSignature IProject Name SEAL OF ENGIEERNG QUALITY Project manager Engineer EXPIRES 08 -21 -08 Southcenter Branch Relocation IProject Number 32.2177.089 IDescription Electrical Riser Diagram IScale E05.01 ? 2006 Gensler E D E U) 0 0 N 0 N 3 7 0 1 0 w 0 Q 0 N CT Z w (0 0 0 U, N 0 0 0 N C 3/ #20 (SHIELDED) 1000 FT. MAX. CD FORbt,urti fMuni(OR 103 J MOUNT FACING NORTH SKY HPSA PHOTOCELL HPCU8SS HCLK8SS A • Se, • C -14 J LCP PANEL ID: 115/277 VAC J L C -14 LI24 —S3R -G 1 -347 (1) HPCU8SS (1)HCLK8SS 1 LOCAL DATALINE HDLW4(P) O DATALINE SWITCH HDLS4SS CONTROL ZONES SHALL BE ENGRAVED AS FOLLOWS: VAULT "a" VAULT "b" VAULT LOBBY ( 0 0 J C -14 (Dv K p 3�d 1 (2)WALL SWITCH OCCUPANCY SENSOR UW- 100 -24 MEN'S & WOMEN'S RESTROOM EACH J C -18 C -16 C -16 C -14 0 0 ( 0 0 0 El C -14 C -14 K C -14 FOR CONTINUATION SEE E02.01 C 14 J C -16 _105_ J n C -16 C -16 C -16 0 C -14 C -14 J C -16 C -14 0 C -16 N ER Qr— I I ROOF LIGHTING CONTROL SCHEDULE CONTROL ZONE CIRUIT TIMECLOCK PHOTOCELL SWITCH CALL CUBE C -2 YES 9:00PM — 6:00PM — YES MERCHANT VEST C -4 YES 9:00PM — 6:00PM — YES CORRIDOR /RESTROOMS C -6 YES 9:00PM — 6:00PM — YES TELLER C -8 YES 9:00PM — 6:00PM — YES CENTRAL ZONE C -10 YES 9:00PM — 6:00PM — — CENTRAL ZONE C -12 YES 9:00PM — 6:00PM — EXTERIOR C -14 YES 9:00PM — 6:00PM YES YES EXTERIOR C -16 YES 9:00PM — 6:00PM YES DRIVE THRU SIGN C -18 YES 9:00PM — 6:00PM — YES FLAG POLE C -27 YES 9:00PM — 6:00PM YES SITE C -29 YES 9:00PM — 6:00PM YES YES SITE C -31 YES 9:00PM — 6:00PM YES 1 (2)CEILING MOUNT OCCUPANCY SENSOR UT -300 MEN'S & WOMEN' RESTROOM EACH I J DRIVE -THRU PLAN - POWER & LIGHITNG SCALE: 1/8"=1' —o" B.3 E.5 III ••M• 1111111 MN MI I I I •■ ■ ■11111111■1111 0 4' 8' 16' POWER PACK BZ -100 DATAUNE SWITCH DATALINE SWITCH HDLS2SS HDLS2SS MEN'S RESTROOM CONTROL ZONES SHALL BE ENGRAVED AS FOLLOWS: CALL CUBES "a" CALL CUBES "b" CONTROL ZONES SHALL BE ENGRAVED AS FOLLOWS: NER ROOM NER ROOM "a" "b" DATAUNE SWITCH HDLS4SS CONTROL ZONES SHALL BE ENGRAVED AS FOLLOWS: TELLER DAYLIGHT TELLER TASK LIGHT EXTERIOR LIGHTS EXTERIOR LIGHTS (2) MULTI — BUTTON LOW VOLTAGE SWITCH L3S CONTROL ZONES SHALL BE ENGRAVED AS FOLLOWS: WORK ROOM "a" WORK ROOM "b" POWER PACK LC -100 WORK ROOM LOW VOLTAGE LIGHTING CONTROL ONE -LINE SCALE: NONE DRIVE -THRU NOTES 1. CONTRACTOR TO ROUTE CIRCUIT THRU LIGHTING CONTROL PANEL LCP. NOTE HOMERUNS WITH UNSWITCHED HOTLEG FOR EMERGENCY AND NIGHT LIGHTS. FOR CONTROL SCHEDULE AND DETAILS SEE SHEET E06.01 2. NOT USED. 3. INSTALL J —BOX FOR OPEN /CLOSE SIGN. CONTRACTOR TO CONNECT DRIVE —THRU OPEN /CLOSE SIGN WITH SWITCHES MENTIONED IN THE SHEET NOTE #5. COORDINATE INSTALLATION WITH ARCHITECTURAL DRAWINGS. 4. COORDINATE ALL ELECTRICAL REQUIREMENTS OF DRIVE THROUGH EQUIPMENT WITH TELLER EQUIPMENT INSTALLER INSTALLATION DRAWINGS SHALL BE PROVIDED BY DRIVE THROUGH EQUIPMENT INSTALLER CONTRACTOR IS RESPONSIBLE FOR A COMPLETE INSTALLATION OF ELECTRICAL AND CONTROL WIRING REQUIRED BY DRIVE THROUGH EQUIPMENT INSTALLER 5. COORDINATE STUB UP LOCATION WITH DRIVE THROUGH EQUIPMENT INSTALLER. 6. INSTALL (1) 4 "C. WITH PULLSTRING FROM ATM TO TELEPHONE EQUIPMENT BACKBOARD IN ELECTRICAL ROOM. 7. INSTALL (2) 3�4 "C. WITH PULLSTRING OVERHEAD TO TELLER WINDOW FOR COMMUNICATIONS WIRING FOR DRIVE —THRU EQUIPMENT. 8. INSTALL J —BOX ABOVE CEILING FOR VAT BLOWER MOTORS. INSTALL ONE DUPLEX RECEPTACLE FOR EVERY TWO MOTORS. COORDINATE EXACT LOCATION WITH DRIVE —THRU EQUIPMENT DRAWINGS. 9. INSTALL J —BOX FOR ELECTRICAL CONNECTION TO SIGNAGE. COORDINATE EXACT LOCATION WITH SIGNAGE CONTRACTOR. INSTALL (1 Y2 "C. FROM J —BOX TO SIGNAGE TRANSFORMER LOCATED IN NER ROOM PACK OPENING BY G.C. VERIFY SIZE AND LOCATIONS WITH EQUIPMENT INSTALLER, TYP JUNCTION BOX FOR TELLER CONTROLS, TYP UNISTRUT SUPPORT SYSTEM BY HAMILTON SAFE. G.C. TO PROVIDE CLEAR AREA FOR HAMILTON SAFE TO INSTALL UNISTRUT SUPPORT SYSTEM, TYP COUNTERTOP AND SUPPORT AUDIO CONTROL MODULE, TYP (3)DUPLEX OUTLET FOR CAMERA QUADPLEX RECEPTACLE FOR COUNTER TELLER EQUIPMENT VOICE /DATA OUTLET FOR CPU DUPLEX RECEPTACLE FOR DRIVE THRU MONITORS 1 (2)CEILING MOUNT OCCUPANCY SENSOR DT -300 WORK ROOM DATALINE SWITCH HDLS4SS CONTROL ZONES SHALL BE ENGRAVED AS FOLLOWS: VESTIBULE DAYLIGHT "a" VESTIBULE DAYLIGHT "b" VESTIBULE TASKLIGHTS LIGHTING CONTOL PANEL NOTES: 0 THE LOCAL DATALINE PROVIDES COMMUNICATION AND POWER TO DATALINE SWITCHES. THE MAXIMUM LENGTH OF A LOCAL DATALINE FROM EACH LI PANEL WITH AN AUTOMATION CARD IS (1500ft) USING FREE TOPOLOGY WITHOUT A REPEATER AND (8000ft) USING LINEAR TOPOLOGY. Q THE NETWORK CLOCK (HCLK8SS) AND PHOTOCELL CONTROLLER (HPCU8SS) U THE PHOTOCELL CONTROLLER (HPCU8SS) 1CAN CONTROL ANY GROUP OF RELAYS VIA THE DATALINE. 6 D -22 D -20 v' D -22 D -24 D -2 D -4 Jn.PI.rh.n.m.n.c, i .. —18 D -8 D 2 D -1116 D -20 WALL MOUNT THE "MEDIA RACK" QUAD RECEPTACLE AT 18" AFF DRIVE -THRU TELLER ELECTRICAL ELEVATION SCALE: NONE COMMERCIAL VAT TUBE DUPLEX OUTLET FOR POINT TO POINT MAIN STATION TERMINAL DUPLEX RECEPTACLE FOR DRIVE MONITORS QUADPLEX RECEPTACLE FOR COUNTER TELLER EQUIPMENT VOICE /DATA OUTLET FOR CPU DUPLEX RECEPTCLE FOR VAT VIDEO MATRIX SWITCHER DUPLEX RECEPTACLE FOR AUDIO SWITCHER BOX 01-First Floor (6) D PL RECEPTACLE FOR VAT CONTROL BOXES JUNCTION BOX MOUNTED BELOW THE QUAD RECEPTACLE FOR CONNECTION OF "MODEL RACK" QUAD RECEPTACLES MEDIA RACK frz MODEL RACK THE "MEDIA RACK" IS INSTALLED AFTER THE "MODEL RACKS" AT THE T -18 SCHEDULE DATE PROVIDE SEPARATE CIRCUIT, ISOLATED GROUND QUADPLEX RECEPTACLE FOR USE BY NETWORK RACKS. ROUTE ISOLATED GROUND CONDUCTORS BACK TO GROUND BUS IN PANEL A (2 TYP) RACK MOUNT AT RECEPTACLE AT RACK UNIT 22 AND 24 (APPROXIMATELY 44" AFF) ROUTE 3/4" LIQUID TITE FLEXIBLE METALIC CONDUIT FROM JUNCTION BOX IN WALL ALONG FLOOR TO RACK MOUNTED RECEPTACLE. STRAP CONDUIT TO RACK. NER ROOM RACK ELEVATION SCALE: NONE RECEIVED CITY OF TUKWILA JUL 1.8 2008 PERMIT CENTER €a is • Southcenter Branch Relocation 320 Strander Blvd Tukwila, WA 98188 SERIAL NUMBER: WA0049 NRSP VERSION: 2.0 INCLUDES BULLETIN: 21A Gensler Architecture, Design & Planning Worldwide GLUMAC 1325 Fourth Ave, Suite 1515 Seattle, WA 98101 T. 206.262.1010 F. 206.262.9865 1524 Fifth Avenue Suite 300 Seattle, WA 98101 Telephone 206.654.2100 Facsimile 206.654.2121 r 7 engineers for a sustainable future' III J Job No.: 507023GEN Contact: www.glumac.com IRev Issue Date & Issue Description By Check 02/13/2008 Design Development MA / TM SPV / MAJ 04/30/2008 CD Owner Review MA / TM SPV / MAJ 06/20/2008 Permit / Bid Set MA / TM SPV / MAJ I Seal /Signature SEAL OF ENGNERING QUALITY Procheice Dept PltiectManager Red s IProject Name EXPIRES 08 -21 -08 Southcenter Branch Relocation IProject Number 32.2177.089 IDescription Details - Electrical IScale E06.01 ? 2006 Gensler