Permit EL08-1051 - SABEY DATA CENTER
SABEY DATA CENTER 311 S 120 PL ELO8-1051 Cityif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1051 Issue Date: 08/07/2008 Permit Expires On: 02/03/2009 Tenant: Name: SABEY DATA CENTER Address: 3311 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Phone: Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: TERRY MCCABE Phone: 206 436 -5221 Address: 5614 7 AV S , SEATTLE WA Contractor: Name: VECA ELECTRIC CO INC Address: 5614 7 AV S , SEATTLE WA Contractor License No: VECAECI542MU Phone: 206 860 -0231 Expiration Date: 10/31/2009 DESCRIPTION OF WORK: FURNISH AND INSTALL A NEW 2500A DISTRIBUTION PANEL BOARD FOR FUTURE TENANTS Value of Electrical: 105,000.00 Fees Collected: $1,952.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: _Q(.,,L Date: —� —O u I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of • permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating constructio . e performance gvuor I am authorized to sign and obtain this electrical permit. Signature: �� L L { ;` x Y \_0..) j Date: C1 ! A) Print Name: `., . L t? 4 A 6 J N.)0 ■A/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1051 Printed: 08 -07 -2008 Parcel No.: 1023049069 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3311 S 120 PL TUKW SABEY DATA CENTER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1051 ISSUED 07/23/2008 08/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: �JA LA j A Print Name: CC � Date: C r l —G doc: Cond -Elec EL08 -1051 Printed: 08 -07 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Electrical Permit No. Project No. 1712f5 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 3311 South 120th Place Tenant Name: Sabey Data Center Property Owners Name: Sabey Corporation King Co Assessor's Tax No.: 102-0 14 al0C91 Suite Number: Floor: New Tenant: ❑ Yes © ..No Mailing Address: 12201 Tukwila International Blvd Tukwila WA 98168 City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Terry McCabe Mailing Address: 5614 7th Ave S Day Telephone: 206- 436 -5221 Seattle WA 98109 E -Mail Address: terry. mccabe @veca .com City State Fax Number: 206-763-0505 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA ELECTRIC Mailing Address: 5614 7TH AVE S, SEATTLE, WA 98108 Contact Person: LAURA RANNOW City State Zip Day Telephone: 206- 436 -5245 E -Mail Address: laura . rannow@veca . com Fax Number: 425-696-0128 Contractor Registration Number: VECAECI542MU Expiration Date: 10/31/08 Valuation of Project (contractor's bid price): $ 105, 000 Scope of Work (please provide detailed information): Furnish and install new 2500A distribution panel board for future tenants. Will service be altered? © Yes ❑ No Adding more than 50 amps? © Yes ❑ No Type of Use: Data Center Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel © Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy Seattle City Light H: Wpplications\Fonns•Applications Or Line \4 -2007 - Electrical Permit Application.doc Page 1 oft RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TIIIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1WNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: LAURA RANNOW Mailing Address: 5614 7TH AVE S, SEATTLE, WA 98108 Date: Day Telephone: 2 0 6- 4 3 6 - 5 2 4 5 Date Application Accepted: City State Zip Date Application Expires: OL H:\Applications\Forms- Applications On Line \4 -2007 - Electrical Permit Application.doc Staff Initials: ^ .7-' Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3311 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: EL08 -1051 Status: PENDING Applied Date: 07/23/2008 Issue Date: Receipt No.: R08 -02720 Initials: JEM User ID: 1165 Payment Amount: $1,952.50 Payment Date: 07/23/2008 11:39 AM Balance: $0.00 Payee: VECA ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 043878 1,952.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL P=.,AN - NONRES 000.322.101.00.0 1,562.00 000.345.832.00.0 390.50 Total: $1,952.50 4223 "i7/23 ?710 TOTAL 1252.5 tiro:. Rarstint -f1R Printarl• f17 -23 -9f flR INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION K� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr ige' 79 Type of Inspection: %.�fj Addrg�ss: Date Called: Special Instruction t: Date Wanted:/ Requester: Phone No: oved per applicable codes. LJ Corrections required prior to approval. OMMENTS: Inspecto ��� �� /�� c � /' Date: / / ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Pro'e tel.,Ey Type of Inspection: 7 r ss: Date Called Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COATS: »i3 'll/ Aii F J 6F- Its- r 2 ffalio (-eoa .1",:,6S itiA .%S/r IX Ag /R- r/ AJ d P Mi , c.mm // I D c Da7A&A ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 S Type of Inspecyn:, , _ % x f� r4 --. ..W./.// (--- f Address: Date Called: PZ 4) Aci9 /M/'f' . Special Instructions: Date Wanted: a.m. p.m. Requester: 4.2', /116 Phone N ^ %'j .‘11-1(17. proved per applicable codes. Corrections required prior to approval. COMMENTS: flit r4 --. ..W./.// (--- 1 PZ 4) Aci9 /M/'f' . 41 atiige S G I - T i s - r ,1 C- In irc 14174 :k 4/6 /-/ rate,,/, ? /(g I El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr ' g. Cam— :f, :)V1 :: /,'1A)J Type of Inspection• OrJ/ Ad ss :, . � � .���;J / 1 Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Cam— :f, :)V1 :: /,'1A)J .x'416 ;' J .�l. '/`I)K -.� Ins tor: ` . ! .. / /11// P/ L D7 // El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: 'Date: INSP CTION NO. INSPECTION RECORD Retain a copy with permit kiw-iO3/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Prof /AeJc U Type of Inspection: 700 \,,,..: S�., 2 07 P Date Called: Special Instructions: Date Wanted: ? 8 / .m Requester: Phone No: o` • proved per applicable codes. ❑ Corrections required prior to approval. 1 r OMMENTS: O/— 7zif 606 ,q _cf-AVic,4 KRT 6F,A- c_ Inspgflor: t ter4etwoil Date: $4/70r- $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD 1 Retain a copy with permit 6-0V- 105 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project :tee Q� �w ^� ' X443 ii.T,rIC- Type of Inspection: 2 J2 a00 / -" oo Address: 33 i f 5. /2.0 A. . Date Called: Special Instructions: Date Wanted: VO3 c m: Requester: Phone No: 0 Approved per applicable codes. 0 Corrections required prior to approval. 7 COMMENTS: C 444 ccI,cE9 LJ t t € 5c 1 0J L� Inspector: Date: 0,/03/0'r $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 001-nttRuraSc CkSvfx i" FILE COPY ,0- 2' Permit No. col 0 00G0slo, RECEIVED CITY OF TUKWILA JUL 2 3 2008 PERMIT CENTER ELrn- I ocf VECA Electric swim) MDP -2 -NORTH ROOM: MAIN ELEC ROOM LEVEL 1 SCL TRANSFORMER PAD LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT DESCRIPTION AMP P LOAD kVA AMPS 172.5 PANEL HE 800 .. 3 172.5 207.5 183.2 PANEL LE VIA TRANSFORMER TLE 225 3 183.2 196.3 AMP: 2500 50.4 9.9 PANEL H1 225 3 60.3 72.5 VOLTS: 277 - - 480 - - PHASE: 3 - WIRE: 4 - - BUS TYPE: AL - - A.I.C.: 65K - - M.L.O.: - MAIN CB: • - MAIN FUSE: X - - FLUSH: - - SURFACE: X - - GND. BAR: X - - ISO GND: - - 200% NEU: - - FEED THRU: - - DBL LUG: - - TOP FEED: X - - BTM FEED: - - PANEL T.C.L - - LOAD (kVA) - - RCPT 50.4 - - LTG 9.9 - - EQP 335.7 - - HEAT - - - TOTAL 398.0 - - FEEDER T.C.L. - - LOAD (kVA) - RCPT 50.4 - - LTG 9.9 - - EOP 335.7 - HEAT - - TOTAL 396.0 - - FEEDER DEMAND - - kVA 378.3 TOTAL 398.0 476.3 AMPERES 455.0 50.4 9.9 335.7 - Mfg: SQ D CB: Remarks: Project: IGE BUILDING #2 NORTH SERVICE 07/22/08 Fender T.0 L u printed hen hpvOnyuy to Om • block 'put -Ink' to the 'Load Dubldma+- columns of • sub- had puss or evdErhEenrE 50.4 I 9.9 I 335.7 I - 001-nttRuraSc CkSvfx i" FILE COPY ,0- 2' Permit No. col 0 00G0slo, RECEIVED CITY OF TUKWILA JUL 2 3 2008 PERMIT CENTER ELrn- I ocf VECA Electric LOADS ROOM: FROM: MAIN ELEC ROOM LEVEL 1 PANEL: FEED -THRU: HE SWBD MDP -2 -NORTH A B c RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 6.0 1 INDIGO PRINTER A 50 3 6.0 21.7 6.0 8.0 3 5 INDIGO PRINTER INDIGO PRINTER B 50 6.0 21.7 AMP: 600 C 50 3 8.0 21.7 VOLTS: 277 6.0 7 INDIGO PRINTER A 50 3 8.0 21.7 480 6.0 8.0 INDIGO PRINTER B 50 3 6.0 21.7 PHASE: 3 11 INDIGO PRINTER C 50 3 6.0 21.7 WIRE: 4 6.0 13 INDIGO CHILLER 50 3 6.0 21.7 BUS TYPE: AL 6.0 15 INDIGO CHILLER B 50 3 6.0 21.7 A.I.C.: 17K 8.0 17 INDIGO CHILLER C 50 3 8.0 21.7 M.L.O.: X 6.0 19 INDIGO CHILLER A 50 3 6.0 21.7 MAIN CB: 6.0 21 INDIGO CHILLER B 50 3 6.0 21.7 NEMA 3R: 6.0 23 INDIGO CHILLER 50 6.0 21.7 FLUSH: 25 A 0.0 0.0 SURFACE: x 27 B 0.0 0.0 29 C 0.0 0.0 GND. BAR: X 31 A 0.0 0.0 ISO GND: 33 B 0.0 0.0 200% NEU: 35 C 0.0 0.0 FEED THRU: X 37 A 0.0 0.0 DBL LUG: X 39 B 0.0 0.0 TOP FEED: X 41 C 0.0 0.0 BTM FEED: 6.7 2 NC A 30 3 6.7 24.2 PANEL T.C.L. 6.7 4 NC 30 3 6.7 24.2 LOAD 6.7 6 A/C c 30 3 6.7 24.2 RCPT (kVA) 0.0 8.7 8 A/C A 30 3 6.7 24.2 LTG 0.0 6.7 10 NC B 30 3 6.7 24.2 EQP 172.5 6.7 12 A/C C 30 3 6.7 24.2 HEAT 0.0 6.7 14 A/C A 30 3 6.7 24.2 6.7 16 A/C B 30 3 8.7 24.2 TOTAL 172.5 6.7 18 NC 30 3 6.7 24.2 6.7 20 A/C A 30 3 6.7 24.2 FEEDER T.C.L. 8.7 22 A/C 30 3 6.7 24.2 LOAD 8.7 24 NC 30 8.7 24.2 RCPT (kVA) 0.0 6.7 26 NC A 30 3 8.7 24.2 LTG 0.0 6.7 28 NC B 30 3 6.7 24.2 EQP 172.5 6.7 30 32 A/C C 30 3 A 0.0 0.0 34 B 0.0 0.0 6.7 24.2 HEAT 0.0 TOTAL 172.5 36 C 0.0 0.0 LG MTR 38 0.0 0,0 FEEDER DEMAND 40 0.0 0.0 kVA 172.5 42 C 0.0 0.0 AMPERES 207.5 FEED A 0.0 0.0 THRU B 0.0 0.0 LUGS C 0.0 0.0 0.0 0.0 172.5 0.0 0.0 0.0 57.5 0.0 A 0.0 0.0 57.5 0.0 B 0.0 0.0 57.5 0.0 c 0.0 0.0 172.5 0.0 KVA/AMPS: 57.5 207.6 57.5 207.6 57.5 207.6 Mfg/Type: SO D CB Type: IGE BUILDING 62 NORTH SERVICE 07/22/08 VECA Electric LOADS ROOM: FROM: MAIN ELEC ROOM LEVEL 1 PANEL: FEED -THRU: H1 SWBD MDP -2 -NORTH A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 16.9 1 PANEL L1 VIA TRANSFORMER T1 A 125 3 18.9 61.0 16.9 16.6 3 5 PANEL L1 VIA TRANSFORMER T1 PANEL L1 VIA TRANSFORMER T1 B 125 3 16.9 61.0 AMP: 225 3.3 125 3 16.6 59.9 VOLTS: 277 7 LIGHTING A 20 1 3.3 11.9 3.3 3.3 9 LIGHTING B 20 1 3.3 11.9 PHASE: 480 3 11 LIGHTING C 20 1 3.3 11.9 WIRE: 4 13 SPARE A 20 0.0 0.0 BUS TYPE: AL 15 SPARE B 20 0.0 0.0 A.I.C.: 17K 17 SPARE 20 0.0 0.0 M.L.O.: x 19 A 0.0 0.0 MAIN CB: 21 23 25 B C 0.0 0.0 0.0 0.0 NEMA 3R: FLUSH: A 0.0 0.0 SURFACE: X 27 0.0 0.0 29 C 0.0 0.0 GND. BAR: X 31 A 0.0 0.0 ISO GND: 33 B 0.0 0.0 200% NEU: 35 C 0.0 0.0 FEED THRU: 37 0.0 0.0 DBL LUG: 39 B 41 C 0.0 0.0 TOP FEED: X 0.0 0.0 BTM FEED: 2 0.0 0.0 4 0.0 0.0 PANEL T.C.L. LOAD 6 C 0.0 0.0 RCPT (kVA) 50.4 8 A 0.0 0.0 LTG 9.9 10 0.0 0.0 EQP 0.0 12 C 0.0 0.0 HEAT 0.0 14 A 0.0 0.0 16 0.0 0.0 TOTAL 60.3 18 C 0.0 0.0 20 0.0 0.0 FEEDER T.C.L. 22 B 0.0 0.0 LOAD 24 C 0.0 0.0 RCPT (kVA) 50.4 28 A 0.0 0.0 LTG 9.9 28 B 0.0 0.0 EQP 0.0 30 0.0 0.0 HEAT 0.0 32 A 0.0 0.0 34 B 0.0 0.0 TOTAL 60.3 38 0.0 0.0 LG MTR 38 0.0 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 42.6 42 C 0.0 0.0 AMPERES 51.2 A 0.0 0.0 FEED B 0.0 0.0 THRU 0.0 0.0 50.4 9.9 0.0 0.0 LUGS 16.9 3.3 0.0 0.0 A 16.9 3.3 0.0 0.0 B 16.6 3.3 0.0 0.0 C 50.4 9.9 0.0 0.0 KVA/AM PS: 20.2 72.9 20.2 72.9 19.9 71.8 Mfg/Type: SO D CB Type: IGE BUILDING #2 NORTH SERVICE 07/22/08 VECA Electric LOADS ROOM: FROM: MAIN ELEC ROOM LEVEL 1 PANEL: FEED -THRU: LE SWBD MDP -2 -NORTH VIA XFMR TLE A B C RCPT LTG EQP HEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 4.8 iGEN -SUB A 50 4.8 40.0 4.8 4.8 4.8 3 5 7 iGEN -SUB iGEN -SUB IGEN -SUB B 50 50 1 4.8 40.0 4.8 40.0 AMP: VOLTS: 600 120 A 50 4.8 208 9 SPARE 20 0.0 0.0 PHASE: 3 11 SPARE C 20 1 0.0 0.0 WIRE: 4 13 SPARE A 20 0.0 00:� BUS TYPE: AL 15 SPARE B 20 0.0 A.I.C.: 17K 17 SPARE 20 0.0 0.0 M.L.O.: X 19 SPARE A 20 0.0 MAIN CB: 21 B 0.0 0.0 NEMA 3R: 23 0.0 0.0 FLUSH: 25 A 0.0 0.0 .. �..„ SURFACE: X 27 B 0.0 0.0 29 C 0.0 0.0 GND. BAR: X 31 A 0.0 ISO GND: 33 B 0.0 200% NEU: 35 C 37 A 0.0 39 B 0.0 0.0 0.0 FEED THRU: DBL LUG: 0.0 r' TOP FEED: X 41 0.0 0.0 BTM FEED: 12.0 2 iGEN -MAIN A 125 3 12.0 100.0 °_.�...:.. PANEL T.C.L. 12.0 4 iGEN -MAIN B 12.0 100.0 LOAD (kVA) 12.0 6 iGEN -MAIN C 12.0 100.0 RCPT 0.0 12.0 8 IGEN -MAIN A 125 3 12.0 100.0 LTG 0.0 12.0 10 iGEN -MAIN B 12.0 100.0 1.-t EQP 163.2 12.0 12 iGEN -MAIN C 12.0 100.0 HEAT 0.0 12.0 14 iGEN -MAIN A 125 3 12.0 100.0 ,' 12.0 16 iGEN -MAIN 6 12.0 100.0 TOTAL 163.2 12.0 18 iGEN -MAIN C 12.0 100.0 12.0 20 iGEN -MAIN A 125 3 12.0 FEEDER T.C.L. 12.0 22 iGEN -MAIN B 12.0 100.0 LOAD (kVA) 12.0 24 iGEN -MAIN C 12.0 100.0 RCPT 0.0 26 A 0.0 LTG 0.0 28 B 0.0 0.0 EQP 163.2 30 C 0.0 0.0 HEAT 0.0 32 A 0.0 34 0.0 0.0 TOTAL 163.2 36 C 0.0 00 LG MTR 38 A 0.0 FEEDER DEMAND 40 B 0.0 0.0 kVA 183.2 42 C A 0.0 B 0.0 0.0 0.0 AMPERES 453.0 C 0.0 0.0 0.0 0.0 163.2 0.0 0.0 0.0 57.6 0.0 A 0.0 0.0 52.8 0.0 B 0.0 0.0 52.8 0.0 C 0.0 0.0 163.2 0.0 Mfg/Type: SO D CB Type: IGE BUILDING #2 NORTH SERVICE KVA/AMPS: 57.6 480.0 52.8 440.0 52.8 4400 07/22/08 C 0.0 0.0 C 20 1 1.8 15.0 VECA Electric RCPT 1.0 LOADS ROOM: FROM: MAIN ELEC ROOM LEVEL 1 PANEL: L1 FEED -THRU: PANEL H1 VIA XFMR T1 LTG EQP HEAT CKT 1 OFFICE RECEPTACLES PH AMP P A KVA AMPS KVA B AMPS KVA C AMPS 1.0 1.0 OFFICE RECEPTACLES 20 1 1.0 1.0 3 A 20 1 1.0 8.3 5 OFFICE RECEPTACLES 20 1 1.0 7 OFFICE RECEPTACLES A 20 1.0 8.3 ! =3 1.0 9 11 OFFICE RECEPTACLES OFFICE RECEPTACLES B 20 1 1.0 8.3 8.3 1.0 AMP: 225 8.3 VOLTS: PHASE: 120 208 3 C 20 1 1.0 1.0 13 BREAK ROOM RECEPTACLE 20 1 1.0 1.0 8.3 1.0 15 17 BREAK ROOM RECEPTACLE BREAK ROOM RECEPTACLE B C 20 1 20 1 1.0 1.0 19 BREAK ROOM RECEPTACLE A 20 1.0 1.0 8.3 WIRE BUS TYPE: A.I.C.: 4 AL 10K 1.0 8.3 1.0 21 23 BREAK ROOM RECEPTACLE BREAK ROOM RECEPTACLE B 20 1 1.0 8.3 M.L.O.: MAIN CB: NEMA 3R: X 20 1 0.3 0.3 25 BATHROOM GFI A 20 0.3 2.5 1.0 8.3 27 BATHROOM GFI 8 20 0.3 FLUSH: SURFACE: x 29 31 SPARE SPARE 20 1 00 00 GND. BAR: x 33 SPARE 20 1 0.0 0.0 ISO GND: 35 SPARE 20 1 0.0 200% NEU: C 20 1 37 SPARE A 20 1 0.0 0.0 0.0 39 41 SPARE SPARE 20 1 0.0 0.0 FEED THRU: DBL LUG: X TOP FEED: 20 0.0 0.0 BTM FEED: X 1.8 2 SHOP FLOOR EQUIPMENT A 20 1 1.8 1.8 1.8 4 6 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT B 20 1.8 PANEL T.C.L. LOAD C 20 1 1.8 1.8 8 10 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT A 20 1.8 15.0 1.8 15.0 RCPT LTG (kVA) 12.6 0.0 1.8 12 SHOP FLOOR EQUIPMENT B 20 1 1.8 15.0 EQP 37.8 1.8 14 SHOP FLOOR EQUIPMENT C 20 1 1.8 15.0 HEAT 0.0 A 20 1 1.8 1.8 1.8 18 18 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT 20 1 1.8 15.0 TOTAL 50.4 1.8 1.8 20 22 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT A 20 1 1.8 24 SHOP FLOOR EQUIPMENT B 20 1 1.8 26 SHOP FLOOR EQUIPMENT C 20 1 1.8 15.0 -_ FEEDER T.C.L. LOAD 1.8 15.0 RCPT (kVA) 12.6 20 1 1.8 1.8 28 SHOP FLOOR EQUIPMENT B 20 1 1.8 1.8 1.8 30 32 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT 20 1 15.0 1.8 15.0 LTG EQP HEAT 0.0 37.8 0.0 A 20 1 1.8 1.8 1.8 34 36 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT B 20 1.8 TOTAL 50.4 1.8 C 20 1 1.8 15.0 LG MTR 1.8 38 40 SHOP FLOOR EQUIPMENT SHOP FLOOR EQUIPMENT A 20 1 1.8 15.0 FEEDER DEMAND 1.8 B 20 1 1.8 15.0 kVA 49.1 42 SHOP FLOOR EQUIPMENT C 20 1 1.8 15.0 AMPERES 136.3 A 0.0 0.0 0.0 12.6 0.0 37.8 0.0 4.3 0.0 12.6 0.0 A 4.3 0.0 12.6 0.0 B 4.0 0.0 12.6 0.0 C 12.6 0.0 37.8 0.0 Mfg/Type: Sq D CB Type: IGE BUILDING 92 NORTH SERVICE KVA/AMPS: 16.9 140.8 16.9 140.8 16.6 138.3 07/22/08 • Pt GOURD COPYM PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1051 DATE: 07 -23 -08 PROJECT NAME: SABEY DATA CENTER SITE ADDRESS: 3311 S 120 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ^'G Bu ing ivision Public Works Fire Prevention Structural n El Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1 Incomplete Comments: n DUE DATE: 07-24-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments cetermined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08-21 -08 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • • Page 1 of 3 Electrical Contractor A business licensed by L£tI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. VECA ELECTRIC CO INC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7TH AVE 5 PO BOX 80467 SEATTLE WA 98108 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 601190731 ACTIVE VECAECI542MU ELECTRICAL CONTRACTOR 7/31/1946 10/31/2009 CONTIK`965D6 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License CONTIK`965D6 Name CONTI, KEITH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON AGENT 01/01/1980 929407110 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Until Cancelled $4,000.0001/06/2007 TRAVELERS https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License = VECAECI542MU 08/07/2008 0 P- c 0 N 0 0 m co Q N CJi J W Z d w z w z 0 O C7 ❑ w C7 42 c a) ❑ a-. a) rn v ❑ C5 r1 /\ TO SCL POLE SCL PADMOUNT XFR 1500KVA PRIMARY TO X480/277 SIBEY DIST. SWBD "MDP -2" - ------ _....._ - - -- - -- -- -- --------------- - -- 480/277 2500A 65KAIC SPARE 3P 25004 PNL HE 480/277 600A MLO FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 25004 (6 SETS) 4 "C 4 #600KCMIL & 1 #350 KCMIL G PER SET 2 "C 3 #4/0 & 1 #4 G 2 "C4 #4/O& 1 #4G 1 "C 3 #1 & 1 #6 G soao4 (2 SETS) 3 "C 4 #35OKCMIL & 1 #1 G PER SET 4004 3 "C 4 #500KCMIL & 1 #2 G ( 41::: 3 "C 3 #500KCMIL & 1 #2 G ARCHITECTURE CONSULTANTS PNL LE 208/120 600A MCB PNL H1 480/277 225A MLO PNL L1 208/120 225A MCB SCALE: NTS SCL POLE SCL PADMOUNT XFMR 1500 KVA SCL POLE 225 KVA XFMR SWOD MDP PNL Hi J pNL LI 75 KVA XFMR PERMIT REQUIRED FOR: lieMechanical ❑ Electrical 4/Plumbing [VGas Piping City of Tukwila BUILDING DIVISION CONSULTANT: Vera Electric 5614 7th Ave. South Seattle, WA 98108 Ph (206) 436 -5200 Fx (206) 763 -0505 www.veca.com REVISIONS 7/22/08 PROGRESS DRAWING KJA FILE COPY Permit No. 6- Pl r review approval is subject to errors and omissign . Approval of construction documents does not auth9rize the violation of any adopted code or ordinance. Regipipt of approved ;Fi, "ld Copy-and-c nditions is acknowieqcpci; c - "'\N. -0 Date: 1 ( City of Tukwila BUILDING DIVISION \:— -°"__ REVISIONS No changes shall be made to oope of work without prior app val of Tukwila Building Division Submit +�i NOTE: Revisions will require a Ian rplan`"' bmi fi and may include additional plan RECEIVED .a- CITY OF TUKWIL.A JUL 2 3 7008 PERMIT CENTER X X- -X ><_>E — >< > < —X ><—>< X ><-- >< —>E- < >< ><--><--X X - - - - -> - - ->K ><—><—>--<--><-->e _ -X - -X >(—X—X - >E— >E-- - ->< -- >< — ><- -><—>< >< ><--X _ ->E}- %F X X ><-- *—x-- —X--X >< X>< >< >< >< X >< < >< >< >< X ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concept of the Sabey Corporation. SABEY BUILDING 2 NORTH 3311 S. 120th PL Tukwila, WA., 98168 Thregiciteo e Nb . DRAWING TITLE: FILE: PLOT: PROJECT NUMBER: 89007 DRAWN BY: CHECKED BY: APPROVED BY: DRAWING NUMBER: IGE SABEY DATA CENTER BUIDLING #2 NORTH SCALE: 1/8"=1'--0" SITE LAYOUT BUILDING 2 NORTH NORTH CD FEEDER SCHEDULE 3 —PHASE 3 WIRE + GROUND SYMBOL FEEDER SIZE — CONDUIT & WIRE SIZE + GROUND 25004 (6 SETS) 4 "C 4 #600KCMIL & 1 #350 KCMIL G PER SET 2 "C 3 #4/0 & 1 #4 G 2 "C4 #4/O& 1 #4G 1 "C 3 #1 & 1 #6 G soao4 (2 SETS) 3 "C 4 #35OKCMIL & 1 #1 G PER SET 4004 3 "C 4 #500KCMIL & 1 #2 G ( 41::: 3 "C 3 #500KCMIL & 1 #2 G ARCHITECTURE CONSULTANTS PNL LE 208/120 600A MCB PNL H1 480/277 225A MLO PNL L1 208/120 225A MCB SCALE: NTS SCL POLE SCL PADMOUNT XFMR 1500 KVA SCL POLE 225 KVA XFMR SWOD MDP PNL Hi J pNL LI 75 KVA XFMR PERMIT REQUIRED FOR: lieMechanical ❑ Electrical 4/Plumbing [VGas Piping City of Tukwila BUILDING DIVISION CONSULTANT: Vera Electric 5614 7th Ave. South Seattle, WA 98108 Ph (206) 436 -5200 Fx (206) 763 -0505 www.veca.com REVISIONS 7/22/08 PROGRESS DRAWING KJA FILE COPY Permit No. 6- Pl r review approval is subject to errors and omissign . Approval of construction documents does not auth9rize the violation of any adopted code or ordinance. Regipipt of approved ;Fi, "ld Copy-and-c nditions is acknowieqcpci; c - "'\N. -0 Date: 1 ( City of Tukwila BUILDING DIVISION \:— -°"__ REVISIONS No changes shall be made to oope of work without prior app val of Tukwila Building Division Submit +�i NOTE: Revisions will require a Ian rplan`"' bmi fi and may include additional plan RECEIVED .a- CITY OF TUKWIL.A JUL 2 3 7008 PERMIT CENTER X X- -X ><_>E — >< > < —X ><—>< X ><-- >< —>E- < >< ><--><--X X - - - - -> - - ->K ><—><—>--<--><-->e _ -X - -X >(—X—X - >E— >E-- - ->< -- >< — ><- -><—>< >< ><--X _ ->E}- %F X X ><-- *—x-- —X--X >< X>< >< >< >< X >< < >< >< >< X ISSUE DATE All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written concept of the Sabey Corporation. SABEY BUILDING 2 NORTH 3311 S. 120th PL Tukwila, WA., 98168 Thregiciteo e Nb . DRAWING TITLE: FILE: PLOT: PROJECT NUMBER: 89007 DRAWN BY: CHECKED BY: APPROVED BY: DRAWING NUMBER: IGE SABEY DATA CENTER BUIDLING #2 NORTH SCALE: 1/8"=1'--0" SITE LAYOUT BUILDING 2 NORTH NORTH