Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-1158 - WESTFIELD SOUTHCENTER MALL - T-MOBILE
T- MOBILE 718 SOUTHCENTER MALL ELO8-1 158 CitOif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: htip://www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 718 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1158 Issue Date: 10/03/2008 Permit Expires On: 04/19/2009 Tenant: Name: T- MOBILE Address: 718 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MICHAEL CADY Phone: 425 - 785 -0444 Address: 19807 NORTH CREEK PKY N , BOTHELL WA Contractor: Name: AUBURN ELECTRICAL SERVICE INC Phone: 253 833 -2789 Address: 29410 110 AV SE , AUBURN WA Contractor License No: AUBURES953LT Expiration Date: 06/30/2009 DESCRIPTION OF WORK: ELECTRICAL TENANT IMPROVEMENT OF NEW MALL SPACE. NEW FIXTURES AND LIGHTS 10 -22 -08 REVISION #1: ADD (1) LOW VOLTAGE THERMOSTAT WIRE Value of Electrical: $13,600.00 Fees Collected: $389.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: LJJL /\ Date: l V)--)-- d-)- - O CJ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: c."-' Date: 7O 22- V� Print Name: 5 % c �4i / , ZOoiJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1158 Printed: 10 -22 -2008 Cityilhf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 718 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1158 Issue Date: 10/03/2008 Permit Expires On: 04/01/2009 Tenant: Name: T- MOBILE Address: 718 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MICHAEL CADY Phone: 425 -785 -0444 Address: 19807 NORTH CREEK PKY N , BOTHELL WA Contractor: Name: AUBURN ELECTRICAL SERVICE INC Phone: 253 833 -2789 Address: 29410 110 AV SE , AUBURN WA Contractor License No: AUBURES953LT Expiration Date: 06/30/2009 DESCRIPTION OF WORK: ELECTRICAL TENANT IMPROVEMENT OF NEW MALL SPACE. NEW FIXTURES AND LIGHTS Value of Electrical: $13,500.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY $389.50 2005 Permit Center Authorized Signature: 1)4A- Date: to 6 01A I hereby certify that I have read and a amiaed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied djith whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or a performan a of work. I am authorized to sign and obtain this electrical permit. Signature: ( T Date: /0 3 08 Print Name: ' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1158 Printed: 10 -03 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: T- MOBILE • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 718 SOUTHCENTER MALL TUKW PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1158 ISSUED 08/21/2008 10/03/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature at��-' - Date: -0& Print Name: , doc: Cond -Elec EL08 -1158 Printed: 10 -03 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.cLtukwila.wa.us 0 Electrical Permit No. EL-i9— 1 S$ Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION RPV Site Address: 719 ,,``�A'2 d eX / Tukw 1a )1ok Ite Tenant Name: King Co Assessor's Tax No.: 6,34,ie 6196 10 Suite Number: Property Owners Name: q> Pr Mailing Address: P0 1'60940 Floor: New Tenant: ❑ Yes ❑..No atr(slas&Q City CA State qt2..o l3 Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued ktAatoi Day Telephone: 42,6 75 -0144 Name: �,,� p�, Mailing Address: 1 Q 7 >Fa Pot:kill (�/� ?gait City State Zip Fax Number: 425 3c18- 7620 E -Mail Address: MI dad Cadti t— mDbt&L_cOivt ELECTRICAL CONTRACTOR INFORMATION Company Name: Euert?reeh Porar & tho 4 4) Mailing Address: 39 i t AutlAve &/i Secitte L City so Contact Person: Jam E. ha,euey Day Telephone: az 774- i4 E -Mail Address: J Fax Number: Contractor Registration Number: EVER6PS 9S0 BE Expiration Date: WA g8131 State Zip Valuation of Project (contractor's bid price): $ 1315Qo Scope of Work (please provide detailed information): %rauovz lrf rOUKK 4Y d t %, (Q $V✓e &j :, Ybr.) Ault). bVjo aPte(._ Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H:\Applications \Forms - Applications On Line \42007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ca ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ca ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ca ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENAL OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 W '! R ' E .. SRICAL CONTRACTOR: Signature: Print Name: I.A Mailing Address: iq& i Wolk CADA Zit ___ tA00 Date Application Accepted: g„._01.1 9 (((( 'l Date: eezi Day Telephone: 12S" 711S• 0444 Bpiittit City taht State Zip Date Application Expires: 2?)4 -O9 Staff Initials: H.1Applicatinns\Fnnns -Applications On Linet4 -2007 - Electrical Permit Applicatinn.dot bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwi/a.wa.us SET RECEIPT RECEIPT NO: R08 -03065 Initials: WER User ID: 1655 Payee: HAWK BUILDING Payment Date: 08/27/2008 Total Payment: 2,059.08 SET 1D: 0827 SET NAME: T- MOBILE SET TRANSACTIONS: Set Member Amount D08 -410 1,574.30 EL0:8a1f1583 77.90 M08 -212 365.88 PG08 -231 41.00 TOTAL: 2,059.08 TRANSACTION LIST: Type Method Description Amount Payment Check 70034 2,059.08 TOTAL: 2,059.08 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 77.90 000/345.830 1,981.18 TOTAL: 2,059.08 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -1158 Address: 718 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/21/2008 Applicant: T- MOBILE Issue Date: Receipt No.: R08 -03434 Payment Amount: $311.60 Initials: JEM Payment Date: 10/03/2008 08:35 AM User ID: 1165 Balance: $0.00 Payee: AUBURN ELECTRICAL SERVICE INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8910 311.60 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 311.60 Total: $311.60 doc: Receipt -06 Printed: 10 -03 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit (1.4:•\ I-1(5V PERMIT NO. Project: i : ilotStue Type of Inspection: /100 Address: a 11414., Date Called: Special Instructions: Date Wanted: / 0/Z7— t , Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: .ill r Date: loit7,lag ❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: eb �r�..sr._ -rte ate..• auras.. �. ti..� . _.e .. • ... . r. Ye.% NE.. 'a�1�r�'.. .4/11.• ` •r • . _ . r a ..)--eel INSPECTION RECORD Retain a copy with permit 60 1151 INSPECTION NO. PERMIT NO. / CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 3 Project: ,d 0 & j / z 7003 `- Type of Inspection_O 7. Address: IN ' v"i�1..I Date Called: Special Instructions: Date Wanted: 10/Li p.m. Requester: Phone No: cgs Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 12K, - SekJta 19. GErunk CoJo'c Inspector: Date: (0 /Z- /;r El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 4 .0.41.. .•rre t.� 011�w.. �Y...i _. r:... rny(. ��.ri �w .w "••. ` •Lb....�..:.+7Ym...._ _ -�. _ INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION '(2' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36;7 tov- Pro ect: / ''''r: Pt* L, Type of Inspection: / 003 Address: 1 11 n Date Called: Special Instructions: Date Wanted: J 10/ 03 p.m. Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: I2A - c-��,� FL04 GEILu�, 57� Ic+2o.J-r 57 Inspector: -Tit/ &-AWc-i\ 'Date: o 3 Jd? ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: I INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 1� 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 PERMIT NO. Project: o `� Type of Inspection: 7o03 Address: 74 ' w � Date Called: Special Instructions: Date Wanted: ,Q /0\i a:m Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pa 13Ao( Roori5 wb49 Inspector: �✓} l t/ 1Date: r0 /c47 4" r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: �-� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3fj7 Project: ! _ �"� OS ( Type of Inspection: /7°4-- Address: 1 IV tiAlk, Date Called: Special Instructions: Date Wanted: x®/04 a:m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: K. km9c-csLA Date: !O f �,, $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 0 Prescriptive • Lighting Power Allowance O Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans. CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2008 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Project Info Project Address n c I �,J_ _ , /) Tuktkltt& VA r'�pa(x Qt3 l Ea Revised July 2007 Applicant Name: Applicant Address: Iq&o7 L Applicant Phone: 125 -- igTTTT� -no , Project Description (Yak /trKL q11 Date �}_a) -0p For Building Department Use FIE COPY g r,� ❑ New Building ❑ Addition -['Alteration ❑ plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option Alteration Exceptions (check appropriate box - sec. 1132.3) Occupancy Description No changes are being made to the lighting • llowed x Area • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. /.� Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 llowed x Area Wait /.� j,?Z� 2,5Az<o FOP AWE® ** From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 45197.SD Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed .3 41 33 L'Q ot3 FOP AWE® CO'FPA 7®" "EC ..�'t! l WING DIVISICIN Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Wafts 3, q 2 3 ores: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fbdure, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Refere may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt listhtino. note section and exception number, and leave Watts/Fixture blank. !ELO8 ELO8v its ''n IVED AUG 2 1 PERMIT CENTER CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (bac,k)'1 LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers O Other Q ualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 • Check if 95% ° or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA) Use' LPAIW /st) Use LPA' (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)"'." 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 AP Dormitory 1.0 Retail1O retail banking, mall concourses, wholesale stores (pallet rack shelving) Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia°, assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference /exhibition hall'•0 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted tor Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 ootnotes or 1 able t b- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 15062 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/fte may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft' of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -LPA Project Address 7Ig Svicatier Wait , �kah l a 6618b rate 8 .aI -og Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for in erior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Revised July 2007 Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception ** Adjusted LPA Watts per ft2 1.5 1 ** From Table 15 -1 based on exceptions listed in footnotes • PERMIT COORD COPP PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1158 DATE: 08 -21 -08 PROJECT NAME: T- MOBILE SITE ADDRESS: 718 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: A6A)C, el, -opt Bui ing'Division Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator t-/ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08 -26 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 09 -23 -08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2.28 -02 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /0 ~ 2Z ^ 0 B Plan Check/Permit Number: aL v 8 - I I 5' 8 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: T V►'lo g L� Sou CC-A /E,2 71(3 50 ,ACC-ei /FA P,RVwj ST�u t= Phone Number: 253 - 2‘, I " 5 )5 / Summary of Revision: /100 1 A64mos biT 6- 44,'!? RECEIVED CITY OF TUKWILA OCT 2 2 2008 Sheet Number(s): "Cloud" or highlight all areas of revision including"kte of rev �c Received at the City of Tukwila Permit Center by: ntered in Permits Plus on \applications\fonns- applications on line\revision submittal Created: 8 -13 -2004 Reviced. Untitled Page • 0 Page 1 of 2 Electrical Contractor A business licensed by LW to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company AUBURN ELECTRICAL SERVICE INC 2538332789 29410 110TH AVE SE AUBURN WA 98092 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602513331 ACTIVE AUBURES953LT ELECTRICAL CONTRACTOR 6/30/2005 6/30/2009 AUBURES165NA BOONES*950LF GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License BOONES*950LF Name BOONE, STEVEN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BOONE, PEGGY J AGENT 06/30/2005 BOONE, PEGGY J PRESIDENT 06/30/2005 BOONE, PEGGY J SECRETARY 06/30/2005 BOONE, STEVEN R TREASURER 06/30/2005 BOONE, STEVEN R VICE PRESIDENT 06/30/2005 https: / /fortress. wa. gov /lni/bbip/Detai 1. aspx ?Li cense= AUBURES 95 3 LT 10/03/2008 nor COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary llability. MIMS CO Flo* alai >IV ilgu=4 2 to op L. 2 cn w c av wAr +040 trs u .,yea BA 0 TIE 4 ma ell 2112 wgmX a R aQ 2M1 IA 0 z W 0 <IC CZ. U t� 2 U W Le▪ i • Ln —N in co co O oN vt N E • o)�qq,r 111 "0 CY+4 8+ F +1 480 998 7223 RECEIVE AUG 21 2000 EMT CENTEb DATE: SCALE: DRAWN BY: PROJECT No.: O5.14.06 SHEET: 1/4 " P-Qu STAPP, E 10 0 TMSOaOI ,i (N) 20. FOR TELEPHONE SERVICE NEIN TELEPHONE BACKBOARD PROVIDE CABLE RUNWAY FROM TOP OF EQUIP. CADINET TO TmLe. BACKBOARD £'1'I MO NT., (c IN DUCT LAN L CATI LORD TELEPHONE t.YE.F.IFY\EXACT N) IP A EQUIP. CABINETS BY OTHERS T'STAT, 4" fkFF(TYP) TEM, 45" 055MS CONTROLLER AND POWER SUPPLY E5O2 r I ▪ I _dam Fatal_ I.25" C. TO ACCESS15LE CEILING 0 24" ArF 24" AFF 0 24" AFF L.. TEM, 45" AFF 45" AFF LIGHTING coNTROL. PANEL "LCP" 45" AFF 1.25" c. TO DATA RACK - ,..N\ 1.25" C. To ,..ACcESSII5LE CEIL1N6 -41 I E 1,25" C. TO A C.--ESSIE31..E7 1- . ,. ...,.,.. ._. iJt 1: 7,11 I 02 .1.25" 0, TO FILING T 1.25" a. TO ACCESSIBLE CEILING 5/4" C. To MUZAK AT TELEPHONE 15AcKBoARD--- 0 :ta • ACCESSIBLE 6 12" AFF ECTRICAL SIGNAL PLAN 24" AFF 0 24" AFF 1.25" C. TO ACCESSIBLE CEILING • I 0 ®12" AFF -1.25" ACCE CEILI IT 000 0 0 0 YLlg. I \ I r 1 1 q 1.25" IC —TO ACCESSIBLE 1 24 GENERAL NOTES *REFER.TO sHET E 400 raiz EM5 INFORMATION. *ALL LOW VOLTA e CABLING SHALL 5E RUN IN LOW VOLTA 0E PATHWAY SYSTEM PER DETAIL ON SHEET E502. PROVIDE CONDUIT ONLY IF REQUIREDIS'e COPE, • LANDLoRD, OR auesT. SCALE: 1/4" . l'-o" KEYED SIGNAL PLAN NOTES 0 AT FLOORBOX PROVIDE THE REQUIRED QTY OF DEVICE E3RACKETS TO ACCOMMODATE THE oN OUTLETS. COORDINATE EXACT LOCATION OF FLOOR.50X WITH ARCHITECT AND MILLWORK CONTRACTOR. FP-UN CONDUIT BELOW SLA5. PRIOR TO TRENCHING OR CoRIN0, COORDINATE WITH ARCHITECT AND LANDLORD (1)PROVIDE CONDUIT W/PULL CORD STU5-UP FOR LOW VOLT AGE SERVICES TO M1LLWoRK. RUN CONDUIT DOWN1NALL AN TU5-INTO MILLWORK AT A CoNcEALep, ACCESSIBLE LOCATIONINITHIN MILLWORK. COORDINATE EXACT LOCATION OF STU5-IN WITH ARcHITECT AND MILLWORK CONTRACTOR., (1)PROVIDE TWO 4%5%5/4" FIRE RESISTANT PLYWOOD BACK50ARD WITH RECEPTACLES AND 4t6 CU. TO BUILDING &ROUND. SEE TELEPHONE BACKBOARD DETAIL FRoVIPE 2" CONDUIT WITH HEAVY GAUGE PULL CORP FROM LANDLORD TELEPHONE BACKBOARD TO THE TENANT TELE. E3ACK5OARD O FOR SHOPPER TRAK, FLUSH MOUNT OUTLET IN CEILING AND PROVIDE A 5/4" CONDUIT WITH CAT. 5 cAIL E FROM OUTLET To 'TELE. 15AGKOOAFA12. PRIOR TO ROU6H-IN COORDINATE EXACT LOCATION OF OUTLET WITH T-MOBILE • FOR OUTLET moutsiTer, WITHIN MILLWORK, COORDINATE WITH MILLWORK CONTRACTOR FOR EXACT LOCATION oUTDOOFR. TEMPERATURE/ LIGHT LEVEL sels1*,1R. "OTLI" SHOPPER TRAK AT CEILING REV OED VOR ODE COMPL1OCE NRIk 70 - NEC VL? - 10 Oty Of 'Tukwila , • • BUILDING 011:510N COPYREHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work' under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and/or monetary liability. co cp 01 co <Lfl m - co wm C‘.1. cA• rn. • N cii Ct) mm winE rsi ± SULTING ENGINEER U 0 ECEIIVEID AUG 21 Z000 EMIT CENTER DATE: o SHEET: a.14.oa SCALE: DRAWN BY: 1/4" STA PP El 01 PROJECT No.: 1111111111M, Tmeoaoizt EM Reg RC2 (TYP.) a Olt '11M (TYP) WA 5 I ---1-- , M • TA 111 LI 9 liiIL1511 or _„, _ i_ onr 1B6 1 • I ME II 5 0 Fria TiVE7MITIE1111 Ell TEM ME III MI NZ 111111110MENIII 111 111 1111MISI""U 1111 5.1111 A, a> PM ME ME II' 11111441Mi 1111 WAS e IllitiMill1111 Ill MI A 2 01111111111 Immv. ■ RIMEEM MEM ffl =EMMEN- 0 13'6. -1 GK AM2 GK its ELECTRICAL LIGHTING PLAN 0 0 0 0 0 NOTES REFER TO ARCHITE=CTURAL DRAWINGS FOR ALL FIXTURE LOCATIONS. ARCHITECTURAL PLANS ALWAYS TAKE PRECEDENCE OVER THOSE SHOWN ON MEP PLANS. MEP PLANS ARE FOR TECHNICAL INFORMATION ONLY. a u 0 t4` SCALE: 1/4" = 1' -0" KEYED . LIGHTING PLAN NOTES PROVIDE - JUNCTION 13OX, TOGGLE DISCONNECT SWITCH IN NON - VISIBLE LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN FURNISHED ESY OWNER, COORDINATE EXACT LOCATIONS WITH OWNER'S CONSTRUCTION MANAGER. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS WITH U.L. SECTION 2161 REQUIRING THE USE OF SECONDARY GROUND FAULT PROTECTION AND INCLUDE COSTS IN 131D. . SHOW WINDOW RECEPTACLE. LOCATE FLUSH. IN CEILING -- COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE EMERGENCY BATTERY BACK -UP BALLAST FOR NIGHT LIGHT (UNSWITCHEI ) AND EMERGENCY LIGHTS, REFER TO EMS NOTES ON SHEET E401, ALL EMERGENCY/EXIT/NIGHT LIGHTING SHALL, BE CONNECTED TO LOCAL CIRCUIT ON UNSWITGHED LEG FOR CONTINUOUS OPERATION. CODE COMP .t%,' .0 one ef 110G MI COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary llability. w 0 0 C7 co co 41 w m V I✓ f N 68 V g o mm 0 w1 N E N + — I- li13_ltii ,1 tswrog nimmitztvil ty Plil fu R.a ac, ! ;I; cn E +041 o I. al cC t ita to •_ U cu co CONSULTING ENGINEER 0 CCE Wm EriEl 4 IX.; Z LUto ZH9 ZZI CIOM c0 z 0 LA -a ce ra V o 0 to � a1 Z di IT1 F +'f 480 998 7223 ECEIVEL AUG 21 2000 PERMIT CENTEF DATE: 08.14.08 SCALE: DRAWN BY: PROJECT No.: MEET: 1/4" =1' -0" STAFF E200 TME30SO1 I SINGLE -LINE ELECTRICAL RISER DIAGRAM PRIOR TO INSTALLATION, THE ELECTRICAL CONTRACTOR SHALL CONFIRM WITH THE LOCAL INSPECTOR THAT THE PANELS SM N TACCORDAN WIDTH LLOCALTLODES CONTROL MEETS THE REQUIREMENTS OF THE INSPECTOR. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL JURISDICTION. ...,rq.........'rr9•'n . -r" a riii.'t1Y9^VN14.11` RN 1r-re."e•4^xcStftn:rl,31 ELECTRICAL CONTRACTOR SHALL ARRANGE PANELBOARDS TO MATCH LAYOUT ON ¢$ POWER PLAN. ,9037+3 . a"' FHP. ICfml i • 3 .1.133,,W W .•TA ELECTRICAL CONTRACTOR SHALL PROVIDE ALL. EQUIPMENT FULLY RATED FOR AVAILABLE FAULT CURRENT r :M5f1, ",rtrrilti 4Y etpArt asr,.4`. :, lwnn . ' ..trsni..:lY•:!A9:1`tmimeitrunu 1:wmantmm (E) I- I/4 "G., (4) #4, (I) #a GN0., (I) #$ I.6. CU THWN PROVIDED BY LANDLORD (N) I- I /4 "C., (4) #4 CU THWN, (I) #& 6ND, EXISTING SES EXIST' ' 6OA, P MAIN CIRCUIT BREAKER. PROVIDED 5 Y1 LL. EXIST'& METER. PROVIDED B LL. ELECTRICAL SERVICE: 4O-/211V - •,S• 3 M. mtf% CCirt 'duxR504wmRxrrrri,,tY.a %x1V.li ILANDLORC SPACE T.G.G. TO PROVIDE SP/60A DISCONNECT AT TRANSFORMER '(N) I- 1/4 "C., (4) #4 CU THWN, (I) #8 CND. NEW 45 KVA TRANSFORMER (N) 2"C.., (4) #1/0 GU THWN, (I) #6 'ND. 45KVA XFMR (■) I-- I /4 "C., (4) #4 GU THWN, () #8 6ND. (N) PANEL "A" 120/208 VAG,SFH. 22KAIC I2SA MCB #6 6ND T STEIEL 4 LINE PER BUILDING .OLD WATER NEC 250. TENANT SPACE (N) I- I /2 "C., (4) #I CU THWN, (I) #6, CND. (N) PANEL ll5 l 120/208 VAC,SPH. 22KAIC IOOA MLO FLOOR ELECTRICAL RISER DIAGRAM NOTES: I. CIRCUIT BREAKER TYPE PANELBOARDS WITH BOLT -ON TYPE CIRCUIT BREAKERS WITH ADEQUATE INTERRUPTING CAPACITY SHALL BE INSTALLED TO ACCOMMODATE AVAILABLE FAULT CURRENT (AFC). 2. THE GROUNDING SYSTEM WITHIN THE PREMISES :HALL BE CONTINUOUS FROM THE SYSTEM 'ROUND IN THE LANDLORD'S ELECTRIC ROOM, THE SECONDARY OF THE TENANT'S TRANSFORMER SHALL BE &ROUNDED IN ACCORDANCE WITH THE N.E.G. REQUIREMENTS FOR ASEPARATELY DERIVED SYSTEM. - S. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH LOCAL AND' NATIONAL CODES AND IN COMPLIANCE WITH THE LANDLORD'S REQUIREMENTS. ALL MOWER WIRING SHALL BE INSTALLED IN CONDUIT (EMT REQUIRED WW ERE WITHIN PUBLIC VIEW). CONDUCTOR INSULATION SHALL BE THW, THHN, OR THWN. ROMEX AND BL ALLOWED APPROVED BY CCL. JUR SDIG ON, THE LANDLORD, AND WHERE NOT WI N PUBLICIW 4. ALL ELECTRICAL MATERIALS SHALL BE NEW AND SHALL 'BE OF THE NATIONAL ELECTRICAL CODE STANDARD UNLESS BETTER GRADE IS REQUIRED BY LOCAL CODE, AND SHALL BEAR THE UNDERWRITERS' LABORATORIES LABEL. - 5. THE ELECTRICAL SERVICE SHOWN IN THE SINGLE -LINE DIAGRAM IS THE TENANT'S ELECTRICAL CONTRACTOR'S RESPONSIBILITY. OOP NOTE: :LATLYL (TENANT ELECTRIC COORDINATION ANELS ARE TO BE POWER FURNISHED AND INSTALLED EY THE ELECTRICAL CONTRACTOR. 6. HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C.. '7. ELECTRICAL CONTRACTOR SHALL PROVIDE EQUIPMENT RATED FOR THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY FAULT CURRENT LEVELS PRIOR TO ORDERIN& EQUIPMENT. 8. ff.TA . - M.VA R'FiiW.sV .'fxix rms,. rec$ T1PR_ $' I.111404:1 FJ !YrT:'tRCRR.r.EP.ti4 ::` q� I. IO: ELECTRICAL ELECT F ICAL B /C, . T , RE PROP ER CL EQUIPMENT SPAC AVA AREA FRIO ELEGTRICA ELECTRIGA I NFOR ATIO RECORD P TO BIP ELE EXAG EX IS ROUTI 6. Bi EXIST NG S ADDITION 0 12' WIH WITH FEEDER CO I. IF NEW PAN SYSTEM, M AND TYPE. . '., {pRO1rr ,toa rralar•+XtA.TA! 1y2YS PW'k• •41+.0. W.P.'7RWirSI11,11 ." "NIT:. ONTRACTOR SHALL BALANCE ALL PANELS AND QUIPMENT TO "7% ( +) BETWEEN PHASES: A /B, ARDLESS OF CIRCUITING INDICATED. ARANCE MUST BE MAINTAINED ABOUT ELECTRICAL FAR N.E.C. FIELD VERIFY EXACT MOUNTING L.AE'LE IN ELECTRICAL ROOM/ TO INSTALLATION OF ELECTRICAL EQUIPMENT. CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS FOR A COMPLETE 12 O SYSTEM. 15TRIE3UTI _ N OUTLINED ON ONE -LINE DIAGRAM IS BASED ON WINGS AND LANDLORD INFORMATION: PRIOR TRIAL CONTRACTOR SHALL VISIT SITE TO VERIFY IN6 CONDITIONS, FEEDER LEN&THS AND FEEDER SHALL INCLUDE ALL COSTS REQUIRED TO MODIFY THENACCOMMODATE THE TENANT ELECTRICAL V C. •DITIONAL SECTIONS OF MULTI- SECTION PANEL TORS SIZED THE SAME AS THE PANEL > UCTORS. 1.I50ARDS ARE TO BE ADDED TO AN EXISTING T.H EXISTING .PANELBOARD MANUFACTURER • { i ,P'/x4SfA9{,`6°C"wirOVIIV.. ,rrtt NEW LIGHTING CONTROL PANEL. SEE SHEET ESO2 FOR DETAILS. AV CABLE TRAY (REQ'DI ONLY ABOVE AV RACK) N,T.s. TYPICAL IUS CORNER. INTERIOR 2IUS SHALL BE 5" MINIMUM, OU SIDE SIZE WILL VARY WITH TRAY WIDTH. PROVIDE TWO FAST SPLICE FOR CA @LETRAY COUPLING (EZ -EDRN TO DEVICE INSULATED E}USHINS TRAPEZE HAN&ING CLIPS FOR TRAY 8" OR SMALLER WITH (EZ -AS) THREADED ROD AT & FOOT INTERVALS. USE PAS P400, P550, OR P100 FOR TRAYS LARGER THAN 8 ". STARTING AT I FOOT OPP THE FIRST AND AST SEGMENTS OF CABLETRAY. SEE MCP LEVATIONS FOR ACTUAL SPAN LENT EMT TO OUTLET-A". PROVIDE CONDUIT ANCHOR (SBD) - CLAMP CORNERS WITH (GE25 /GESO OR CE25/ED215) CABLETRAY, SEE PLANS FOR SIZE, CORNERS, TEES, ETC. INFORMATION. (EZ -TRAY C.F54 /x00EZ) UNIVERSAL SUPPORT BRACKET (EZ- FASUxOO) SUPPORT TRAK AT & FOOT INTERVALS, STARTING AT I TOOT OFF THE FIRST AND LAST SEGMENTS OF CASLEETRAY. 5 FOOT INTERVALS IN MDF OR IDF. PROVIDE A DIVIDER TO SEPARATE CABLES (EZ -GOT 54) FOR EACH SYSTEM. 6ENl =RAL NOTES: CABLE TRAY MAY BE SUPPORTED WITH OTHER S. CABLETRAY SHALL BE ROUTED AROUND, OVER SUPPORT MECHANISMS THAT THE APPROVED - OR UNDER ANY OBSTACLES THAT INTERFACE WITH THE MANUFACTURER HAS TO OFFER. CONTRACTOR DECLARED PATH. CONTRACTOR' SHALL FOLLOW SHALL OBTAIN, IN WRITING, APPROVAL FROM THE GUTTING AND BENDIN& RECOMMENDATIONS ENGINEER BEFORE ANY SUBSTITUTIONS CAN BE FROM THE MANUFACTURER'S INSTALLATION GUIDE MADE. AS WELL AS THE MINIMUM CABLE E3END RADIUS ALLOWED PER ANSI/TIA /ETA STANDARDS. 2. PROVIDE THE FAS ROLLER TO PULL GABLE INTO CABLETRAY :Ci?P.d+J4.. %t7L'1:f.EJT„° {",moirilrnriff4Ts $: -.» w' .re toceowfli1e¢Lta+$ II. ESTA1TAj!$9f7SPSCX9ft£VAafIP.F :RT9i'„RTMMI:9bh55f!°'AfPidS$S. 1'" .. 94tWlt?7M�i?^` '.7R1 •y},. _......:.. `i. :.. 1/ 4. NOT ALL PARTS , tND P CONTRACTOR IS RESP� INSTALLATION INgLUDIN PROVIDE PART N MBE THE CONTRACTOI, SHA FOR HANES C& T9' THIS 5. ALL CONDUIT STUBSS TO TRAY INDICATED AE0 [ill:L:klt41FC;,f.,p!'l.T. 7R.T:1.'s1.9 . YlitiESIC IV... 'IIVlFtT1• CLAMPING DETAIL RT NUMBERS ARE SHOWN. THE SIBLE FOR A COMPLETE WORKING MISCELLANEOUS APPURTENANCES. AS SHOWN (OR EQUIVALENT). L. ISSUE A SUBSTITUTION REQUEST ETAIL OR PART NUMBERS. CABLE TRAY SHALL BE FASTENED TO VarSalirrarglarK ^?+e•^ 45tms • +etFtltraTSVPAiI OPPER CABLE OR ' OPTICAL FIBER GABLE OTHR LOW VOLTAC7E CABLES PANEL SCHEDULES / LOAD CALCULATIONS PANEL A Service: • It- REM CKT 1201208 Volts II _u! DESCRIPTION 3 1I, " WATT ° Phase WIRE _` ._ BKR 1/20 120 1/20 A X 4 B X C X Wire 125 --, - 1/20 12• 1120 WIRE 12 Cabinets: Surface • .. ..1 •t ' .•,I DESCRIPTION SPARE VAV 0 TR•L SPARE Mounted NEMA WATT` 110 1 CKT 2 REM REM LD ffill 1 3 5 SPARE A - SPARE • SIGNAGE 1120 7 625 • O�i� 1120 1/20 X RI� 500 Ira R WM ills( 2/15 12 AHU -1 1120 R11 : FIR , ti%i of 1LIGHTING- � i 12 I W -E TELEPH a NE :A KB • ARD I EI : REC -TE E- , ON B • BOARD soW1111711111E1 360 I 1120 X 111111 1 20 2/40 - LIGHTING-BOH RR 1 S & DATA ACCU -1 WEN SPARE SPARE SPARE - ® IG 13 REC.- TELEPHONE BACKBOARD IG 1120 1/20 1120 REC.- MANAGERS 1080 1/20 :ax 1111ci :I,rtIK•l,rtt:OCI:I,I4r 1/20 ii CDP -1 2101/4 LD 18 LD LL1 •R L 1500 12 1120 ® 1120 SPARE . 20 21 PARE , REC.-SALES MILLWORK LTS 720�1'ill 111•1111iti �I_ 1/20 NM ®U© 1 20 1/20 iornIcESEME:1317=11 illailagi. 12 3.016: 360071 360 maI 7inurral I IG IG Val REC.-SALES MILLWORK ALARM 720 MNIMILil 60illlll 1/20 Ii7 U FIN ,,, 1/20 NMI 12 ' . EggEZ:=MCMIIIIIIIIIM SPARE 361 rEl Iril IG . - _ . I • , _ 12 I 30 I ( 27 29 - _ .. i � • 9 # :LvIr+1ll= L'1:11T11•11.*),'Lt� 10 ;0 200 12 12 20 1120 U I X X 1120 �i� 1 ' • . - REC. - SHOPPER TRAK 1/20 REC. -DATA RACK 00 10 2130 REC. -SALES CASHWRAP 360 20 WM REC. ALE I L. . PLAY TABLE 31 32 15 11 500 120 X 1120 1 2 � SPARE 34 f c� 33 35 _MINIM 500 10 2130 ri X 1120 Y:,\a4Y•I.F- 9:1'ihttm REC. -SALES BILL PAY REC.-SALES TECH CHAT 360 36 IG 500 360 36 Irli 31100 _ PANEL B 'A' 10.1._ REC.-DATA RACK 37 KgA 5201 f 10317 i REC. -RACK 0 2 2l SPARE X 1120 SPARE 1/20 g , m X TOTAL LOAD PHASE REMARKS TOTAL LOAD PHASE 'B' 11030 (TC) TIME CLOCK CONTROLLED TOTAL LOAD PHASE 'C' 10293 (C#) VIA CONTACTOR (LD) LOCK -ON DEVICE TOTAL LOAD ALL PHASES 31640 WATTS (iG) ISOLATED GROUND 87.89 AMPS (HR) HACK RATED CB (SD) SWITCHING DUTY CB ' ALL BREAKERS TO BE 20A BOLT -ON UNLESS NOTED OTHERWISE PANEL B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface . M.in : 1'0 All . u.LO II Al • T. .lW_s ; . .2 Mounted NEMA 1 REM DEMAND LOAD is 11' DESCRIPTION WATT ` WIRE BKR A I] C BKR 22220 DESCRIPTION WATT ` MHO 11.11111671111111r411 225 %1i NEM BIG 8 1 12 REM LD ffill 1500 1 SPARE 2.3 SIGNAGE 1120 X 625 0.8 1120 ® LIGHTING -SALES 500 Ira R WM ills( REC.-SHOW WINDOW REC. -SHOW WINDOW SPARE : i Mill MiiiERIiiil ti 1120 R11 _ _� IOC ®Fi . x IIMI 1120 I_ of 1LIGHTING- � i 12 SALES LIGHTING -SALES : _ l:az .j :C•L'1'.11i I • 50 i UN 1 20 11111 LIGHTING-BOH RR 1 S & DATA C Lb WI EEI WI 19 SPARE SPARE SPARE 111.... ®® ® 1120 .1/20 1/20 E r U• X 1120 1/20 1120 11.111IMEMMINIMIIIIIMMINIMIll INEMI 14 :ax 1111ci :I,rtIK•l,rtt:OCI:I,I4r 180 16 LD REC: BMS POWER SUPPLY 500 18 LD WATER HEATER 1500 12 1120 1120 SPARE . 20 21 REC. CONVENIENCE NO N/ S REC. - CONVENIENCE SALES 720 720 12 12 1/20 1/20 ®U© 1/20 1/20 12 SPARE 12231MMEZMMIEM REC.- • LE ERV E BAR 360 maI 7inurral 22 24 IG REC. GFI - RESTROOM & RTU'S 60illlll E 1 20 FIN lr 20 12 LD 27 REC. - REFRIGERATOR 1800 12 1/20 1/20 12 REC. -SALES SERVICE BAR 360 28 IG 29 REC PLAY TABLE 36 12 1/20 X 1/20 12 REC. -SALES CASHWRAP 360 30 IG 31 .-SALES REC.-MI R•WAVE 15 11 12 120 1 2 � 1 2 -37Ei ALE CA WRAP RE A f c� _ • - _MINIM ri sp l 1 caI.Z=C• 12 Y:,\a4Y•I.F- 9:1'ihttm REC. -SALES BILL PAY 360 36 Irli Ira SPARE 10.1._ 1/20 X 1/20 wa SPARE EM11111111111111 1120 1/20 1111111101SPARE MEM 38 II r l COILING DOOR MOTOR IET i ��ri� �II�T� - _ ' 111111M1111111111 REMARKS (TC) (D) (IG) (HR) (SD) ra TIME LOCK ISOLATED HACR SWITCHING ALL SPARE 20 ■M X mina REC. -SALES W.T.M. TOTAL LOAD PHASE 'A' TOTAL LOAD PHASE V CLOCK CONTROLLED TOTAL LOAD PHASE 'C' -ON DEVICE TOTAL LOAD ALL PHASES GROUND RATED CB DUTY CB BREAKERS TO BE 20A BOLT -ON UNLESS NOTED OTHERWISE 5585 5840 5201 16626 WATTS 46.18 AMPS ELECTRICAL LOAD SUMMARY 277/480 3 PH - 4W LOAD DESCRIPTION CONNECTED LOA If DEMAND -I •: DEMAND LOAD is 11' DEMAND LOAD u'- 2746 - 3433 4.1 RECEPTACLES 22220 NOTE #1 16110 19.4 WATER HEATERS 1500 1.25 • . 1875 2.3 SIGNAGE 500 125 625 0.8 MISC. 500 1.00 500 0.6 HVAC 4174 . . NOTE #2 5112 6.2 TOTAL 31640 27654 • 33.3 . NOTES: 1. 100% OF FIRST 10,000 WATTS, PLUS 50% OF REMAINING LOAD. 2. 100% OF A/C LOAD, PLUS 25% OF HIGHEST LOAD. RENION CI 01=k CODE. COMPLIINACE. Oti 0'040 -1, X01 COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation. the overall form, arrangement and compositioh of spaces, and elements of the doslgn. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction. building seizure, and /or monetary liability. to co t3 c• m m ui m w u.. t~it • N • m Q "t' E n N +r Nt • c (NI F- r- RIIRAI co To co I. W Q V V )6, O w( 17 03 di 41 rA rrw tA • 02 r�rr• t/i% W J H D 0 Z W Q ua itkik J V DG V QW WD 0 8 Ce5 P Wqp <toN 2116 re W'( 0 z zP" ap �p w ZJg 2 F I II in 002 0 oCI 00 z 0 ramtau sn N N n 0 01 CO to "Fcl ce w 0(V (13 00 ro u N Q o a Z tr. 'd rn - 8 • 7 rr 0 co 0 E 0 DECEIVE AUG 21 ZOO PERMIT CENTE►- DATE: OP .14.05 SHEET' SCALE: DRAWN BY: 1/4" =r-o" T ,* E300 PROJECT No.: TMB080141 ELECTRICAL SYMBOLS LiST A/22 S 5 2 S5 DENOTES LIGHT FIXTURE WITH FIXTURE TYPE DESIGNATED AND CIRCUIT # - EXAMPLE SHOWS FIXTURE TYPE "A ", CIRCUIT NUMBER 22 SINGLE POLE TOGGLE SWITCH, @ 46" UON TWO POLE TOGGLE SWITCH, Cad 46" UON THREE -WAY TOGGLE SWITCH, @ 46" UON OCCUPANCY SENSOR SWITCH (LEVITON), @ 46" UON JUNCTION BOX, SIZE 4 TYPE AS INDICATED OR AS REQUIRED 20 AMP 125V 5W DUPLEX RECEPTACLE, ® I&" UON 20 AMP I25V 5A DOUBLE DUPLEX RECEPTACLE, @ I&" UON 20 AMP I25V 5W ISO - GROUND DUPLEX RECEPTACLE, @ I &" UON 20 AMP 1251/ SW ISO- GROUND DOUE3LE DUPLEX RECEPTACLE, g 1&" LION I -GANG (I) WALKER &5051 FLUSH FLOORBOX. LETTER DESIGNATION FOR &YaT1 =M WIRING, " "- NO PE VICES, "P "- POWER, "D" -DATA 2 -GANG (I) WALKER & &052 PLUSH FLOORBOX. LETTER DESIGNATION FOR SYSTEM WIRING, "- NO DE VICES, "P "- POWER, "D" -DATA 5-GANG (I) WALKER 8&095 FLUSH •FLOORBOX. LETTER DESIGNATION FOR PASS -THRU WIRING, " . "- NO DEVICES,"P "-POWER, "D" -DATA 2-}GANG (I) WALKER 880;.'2 FLUSH FLOORBOX WITH DUPLEX RECEPTACLE AND DUPLEX ISOLATED GROUND RECEPTACLE TEL> . /DATA OUTLET, 4" SQ. 150X w/ SINGLE DEVICE RING & PLATE @ I&" UON . FLUSH CEILING MOUNTED DUPLEX RECEPTACLE }, NON -FUSED DISCONNECT SWITCH SIZED PER NEC IF FUSED DISCONNECT SWITCH, SIZE PER UNIT LABEL, PER NEC MOTOR OUTLET. CONNECTION AS REQUIRED. EQUIPMENT CONNECTION PANELBOARD - SEE SCHEDULE DISTRIBUTION TRANSFORMER, MOUNTING AS NOTED MAIN :SWITCHBOARD OR MOTOR CONTROL CENTER, SEE ONE LINE DIAGRAM POWER TRANSFORMER FOR LOW VOLTAGE LIGHTING CONDUIT RUN CONCEALED BELOW FLOOR OR FINISHED GRADE OR IN FLOOR UNDERLAYMENT CONDUIT CONGEALED IN CEILING OR WALL HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - OVERHEAD . 0 CONDUIT RISER - UP OR DOWN 11/ oft. DENOTES BRANCH CIRCUIT WITH 2 #12 AWG HOT, I #12 NEUTRAL, PLUS EQUIPMENT GROUND WIRE, UNLESS NOTED OTHERWISE. ALL BRANCH CIRCUITS SHALL BE INSTALLED WITH SEPARATE GREEN EQUIPMENT GROUND WIRE SIZED PER NEC. El 0 A SMOKE DETECTOR, MOUNTING AS NOTED. FIRE ALARM MANUAL PULLSTATION, 48" AFF FIRE ALARM COMBINATION HORN /STROBE UNIT, WALL MOUNTED, 80" APF TO BOTTOM OF STROBE LENS DUCT SMOKE DETECTOR FIRE ALARM STROBE UNIT, WALL MOUNTED FIRE ALARM AUDIBLE/ VISUAL UNIT, CEILING MOUNTED. PF-151 SMOKE FIRE DAMPER 0 SHEET NOTE REFERENCE (E) (N) a SECTION DESIGNATION: TOP LETTER INDICATES SECTION, BOTTOM LETTER/NUMBER. INDICATES SHEET DETAIL DESIGNATION: TOP NUMBER INDICATES DETAIL, BOTTOM LETTER/NUMBER INDICATES SHEET ELEVATION DESIGNATION: TOP NUMBER INDICATES ELEVATION, BOTTOM LETTER/NUMBER INDICATES SHEET NUMBER. MECHANICAL 4 PLUMISING EQUIPMENT DESIGNATION DENOTES EXISTING EQUIPMENT, SCHEDULED TO REMAIN DENOTES ELECTRICAL CONTRACTOR PROVIDE NEW PUSHBUTTON, MOUNTED @ 46" UON SELL NOTE: SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. ABBREVIATIONS AFF AHJ A AWG ABOVE FINISH FLOOR AUTHORITY HAVING JURISDICTION • AMPERE AMERICAN WIRE GAUGE BKESD BACKBOARD BLDG BUILDING C CB CKT CL6 CO CONTR CT CU CONDUIT CIRCUIT BREAKER CIRCUIT CEILING CONDUIT ONLY CONTRACTOR CURRENT TRANSFORMER COPPER DIST DISTRIBUTION DS DISCONNECT SWITCH (E) EC EF EL ELEC EM EQUIP FIR EUH EINC EXiST EXISTING EMPTY CONDUIT EXHAUST PAN EMERGENCY LIGHT ELECTRICAL EMERGENCY EQUIPMENT EXISTING TO REMAIN ELECTRIC UNIT HEATER ELECTRIC WATER COOLER EXISTING FACP FIRE ALARM CONTROL PANEL GNP GROUND 6E1 GROUND FAULT CIRCUIT INTERRUPTER HAND /OPE /AUTOMATIC HORSEPOWER HEATER HOA HP HTR J -BOX LTG ILTS LV MGB MI-0 MT MTD MTG HGT (N) NL NF WIC PFB PS PPNL (s) REC SORSW SIG SMR SPKR SS STA TEL TRANS TYP UG UON V VP W WT XFMR JUNCTION .BOX LIGHTING LIGHTS LOW VOLTAGE MAIN.CIRCUIT BREAKER MAIN LUGS ONLY EMPTY CONDUIT WITH PULLSTRI NG MOUNTED MOUNTING HEIGHT NORMAL NEW NIGHT LIGHT NON -FUSED NOT IN CONTRACT PROVIDE FOR FUTURE BREAKER PULLBOX PANEL POWER RELOCATE RECEPTACLE SWITCH SIGNAL SURFACE METAL RAGEWAY SPEAKER SAFETY SWITCH STATION TELEPHONE TRANSFORMER TYPICAL UNDERGROUND UNIT HEATER UNLESS OTHERWISE NOTED VOLTAGE VA POR PROOF WATT OR WIRE WITH WEATHERPROOF WATERTIGHT TRANSFORMER GENERAL ELECTRICAL NOTES I. CIR.SUIT BREAKER TYPE PANELBOARDS WITH BOLT -ON TYPE CIRCUIT BREAKERS WITH ADEQUATE INTERRUPTING CAPACITY SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 2 THE GROUNDING SYSTEM WITHIN THE PREMISE SHALL EE CONTINUOUS FROM THE SYSTEM GROUND IN THE METER ROOM. THE SECONDARY OF THE TENANT TRANSFORMERS SHALL BE GROUNDED IN ACCORDANCE WITH N.E.C. 5 ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH LOCAL SAND NATIONAL CODES. ALL POWER WIRE ON THE PREMISE SHALL SE INSTALLED IN CONDUIT. CONDUCTOR INSULATION SHALL BE THIN, THHN OR THWN. NO ROMEX CABLES ARE 4 ALL. EL CTRICAL MATERIALS SHALL EE NEW AND UNUSED AND SHALL INCLUDE ALL OPTIONAL ITEMS REQUIRED FOR A COMPLETE INSTALLATION. ALL EQUIPMENT SHALL SEAR THE UNDERWRITER'S LABORATORIES LABEL. 5 EX, ROMEX, ARMORED CABLING, ETC. SHALL NOT GEE ALLOWED. . 6 WHEN SPACE ABOVE CEILING 15 INDICATED TO SE A RETURN AIR PLENUM, PLENUM NONCOMEUSTIBLE CONSTRUCTION MATERIALS TO BE USED ABOVE CEILING, INCLUDING EXISTING AND NEW WIRING EXCEPT INSULATION OF 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. LOW VOLTAGE OR LIMITED POWER WIRING MAY BE LABELED PLENUM RATED TYPE. 1 ELECTRICAL CONTRACTOR SHALL PROVIDE ALL SEISMIC SUPPORT (LATERAL AND HORIZONTAL) FOR LIGHT FIXTURES PER THE JURISDICTIONAL REQUIREMENTS. • UON ALL OUTLET HEIGHT. DIMENSIONS SHALL SE TO CENTER OF DEVICE, MEASURED FROM FINISHED FLOOR. q ELECTRICAL CONTRACTOR SHALL PROVIDE PULL STRING IN ALL CONDUITS. 10 ELECTRICAL CONTRACTOR SHALL PROVIDE MOTOR STARTERS FOR ALL HVAC EQUIPMENT AS REQUIRED SY MECHANICAL CONTRACTOR. JI FOR RECEPTACLE LOCATIONS THAT REQUIRE SURFACE MOUNTING, PROVIDE STEEL, RAISED COVER. POWER GENERAL NOTES SECURITY ALARM, DATA AND TELEPHONE SYSTEMS SHALL BE INSTALLED . SY THE TENANT AFTER CASEWORK INSTALLATION. CONDUIT, BOXES AND PULL WIRES TO SE PROVIDED SY THE ELECTRICAL CONTRACTOR. COORDINATE WiTH SECURITY AND TELEPHONE SYSTEMS INSTALLER AT JOB5ITE. . 2 REFER TO MECHANICAL DRAWINGS FOR EXACT HVAC EQUIPMENT LOCATIONS AND SPECIFICATIONS. VERIFY EQUIPMENT WIRE SIZE, CONDUIT SIZES, CIRCUIT BREAKER AND DISCONNECT SIZES WITH EQUIPMENT NAMEPLATE PRIOR TO ROUGH -IN. 5 ALL CONNECTIONS TO HVAC EQUIPMENT SHALL BE MADE WITH COPPER CONDUCTORS ONLY. 4 PROVIDE FUSIBLE DISCONNECT SWITCHES OR HACK CIRCUIT BREAKERS FOR ALL. HVAC EQUIPMENT. FUSE SIZES SHALL BE AS INDICATED ON EQUIPMENT NAMEPLATES. THE ELECTRICAL CONTRACTOR SHALL COORDINATE DISCONNECT SWITCH AND FUSE SIZES WITH ELECTRICAL CONTRACTOR PRIOR TO ORDERING MATERIAL. 5 ALL FUSES FOR THIS PROJECT SHALL 15e EUSSMAN CLASS RK5 DUAL ELEMENT CURRENT LIMITING WITH AMPERAGES AS INDICATED OR REQUIRED. 6 FIRE SAL ALL FIRE WALL PENETRATIONS FOR CONDUITS WITH AN APPROVED FIRE SEALANT AFTER CONDUIT INSTALLATION. FIRE SEAL SHALL PROVIDE EQUAL FIRE RATING. AS WALL. 1 ALL RECEPTACLE CIRCUITS UP TO 100' -0" IN LENGTH SHALL UTILIZE #I2 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM IOI' -0" TO ISO' -O" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS I51' -O" UP TO 250' -0" IN LENGTH SHALL. UTILIZE #8 CONDUCTORS. MINIMUM. CIRCUITS ABOVE 25I' -0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. 8 PLANS ARE PREPARED WITH REQUIRED SRANGH CIRCUITS INDICATED BY CIRCUIT NUMBERS AND HOME RUNS. PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISC. FITTINGS, ETC, FOR A COMPLETE AND OPERABLE SYSTEM. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATION AND NEC. Gi RUN ALL ELECTRICAL WIRING CONCEALED IN WALLS, FLOOR, CEILING OR COUNTERS. EXPOSED WIRING IS NOT PERMITTED. 10 ALL I25V SINGLE PHASE, 2OAMP RECEPTACLES INSTALLED IN THE KITCHEN, BATHROOM, AND ON THE ROOF (IF ROD.) SHALL HAVE GROUND -FAULT CIRCUIT- INTERRUPTER PROTECTION PER NEC. II CONTRACTOR SHALL PROVIDE AND INSTALL ALL JUNCTION AND PULL BOXES REQUIRED FOR THE INSTALLATION OF L.ECTRICAL DEVICES AND EQUIPMENT WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. SIZING OF THE BOXES SHALL SE PER NEC. 12 ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUITS FOR MUSIC SYSTEM, ALARM SYSTEM, P05 OUTLETS, PHONE, DATA, AND ALL OTHER LOW VOLTAGE SYSTEMS (T'STAT, LIFE SAFETY, ETC.) AS REQUIRED. LIGHTING GENERAL NOTES I REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LIGHT FIXTURE AND TRACK LOCATIONS. 2 ALL NIGHT LIGHTS AND EMERGENCY LIGHTS SHALL BE UNSWITCHED. S ALL LIGHTING CIRCUITS UP TO 100 '-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 1O1' -0" TO 150' -0" IN LENGTH SHALL UTILIZE #IO CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0" SHALL UTILIZE #6 CONDUCTORS. 4 ALL LIGHT FIXTURES SHALL SE FURNISHED BY THE OWNER FOR INSTALLATION SY THE ELECTRICAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL SE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF ALL LIGHT FIXTURES. THIS SHALL INCLUDE, BUT IS NOT LIMITED TO PROVIDING ALL SUPPORTS, CLIPS, POWER CONNECTIONS, AND SEISMIC BRACING AS REQUIRED BY THE JURISDICTION. 5 INSTALL EXIT SIGNS OVER DOORWAYS TO MAINTAIN 4" SPACING SETWEEN BOTTOM, OF SIGN AND TOP OF JAMS, OR AT THE DIRECTION OP THE FIRE DISTRICT, • 6 ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE AND ADJUST THE LIGHT FIXTURE INSTALLATION SCHEDULE AS REQUIRED TO ACCOMMODATE THE PATE OF DELIVERY OF THE UWNER FURNISHED LIGHT FIXTURES. CONTRACTOR SHALL IMMEDIATELY IDENTIFY AND REPORT ANY SHORTAGE OF FURNISHED MATERIALS TO THE GENERAL CONTRACTOR. 1 ELECTRICAL CONTRACTOR SHALL INSTALL ALL TRACK HEAPS AT LOCATIONS SHOWN ON PLANS AND ADJUST HEAPS AS DIRECTED BY OWNER. & SEE ARCHITECTURAL DRAWINGS FOR MOUNTING DIMENSIONS AND / OR DETAILS. ARCHITECTURAL SPRINKLERS, SENSORS, • AND OTHER CEILING MOUNTED DEVICES, ETC. IF THERE IS ANY CONFLICT NOTIFY THE ARCHITECT IMMEDIATELY. DRAWINGS SUPERSEDE ALL OTHERS. LIGHT FIXTURE POSITIONS TAKE PRECEDENT OVER DIFFUSERS. -1 ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE WITH ARCHITECT AND LIGHTING DESIGNER FIXTURE MOUNTING DETAILS AND SIZES BASED ON FIELD CONDITIONS. 10 . ALL FIXTURES SHALL SE U.L. OR ETL LISTED AND LABELED. . . . II ELECTRICAL CONTRACTOR TO COORDINATE VOLTAGES. . 12 ARCHITECT TO VERIFY ALL SPECIFIED FINISHES. .15 ELECTRICAL CONTRACTOR SHALL VERIFY ALL LIGHT FIXTURE QUANTITIES AND REPORT THIS INFORMATION TO LIGHTING SUPPLIER. . 14 UON, ALL NIGHT LIGHTS AND EMERGENCY LIGHTS SHALL BE UNSWITCHED. PROVIDE SEPARATE HOT CONDUCTOR, SY- PASSING CONTROLS, TO EMERGENCY BALLAST. . . FIRE ALARM BIDDER DESIGN GENERAL NOTES I TENANT FIRE ALARM SYSTEM SHALL SE PROVIDED SY BIDDER DESIGN SUS- CONTRACTOR AT THE EXPENSE OF THE ELECTRICAL CONTRACTOR. SEE SPECIFICATIONS FOR GENERAL REQUIREMENTS. 2 FIRE ALARM SYSTEM DESIGN WILL BE .DONE UNDER SEPARATE PERMIT DOCUMENTS. FIRE ALARM DESIGN / BUILD CONTRACTOR SHALL BE RESPONSIBLE FOR SHOP DRAWINGS, POINT TO POINT WIRING DIAGRAMS, VOLTAGE DROP CALCULATIONS, SUBMITTAL TO FIRE MARSHALL FOR APPROVAL, DEVICE LOCATIONS, SPECIFICATIONS, AND INTERLOCK •WITH SASE BUILDING FIRE ALARM SYSTEM. COORDINATE ALL FIRE ALARM DEVICE LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION. WORK SHALL INCLUDE INTERLOCK WIRING AND MONITORING OF DUCT SMOKE DETECTORS, FIRE /SMOKE DAMPERS, AND ANSUL FIRE SUPPRESSION SYSTEMS. ADA NOTES LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH, THE MAXIMUM HEIGHT IS REPLCED TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE THAN 25 ", FROM THE WALL BENEATH A CONTROL. LIGHT FIXTURE SCHEDULE MARIE SYMBOL MFGR. / DESCRIPTION LAMPS AM1 0 AMERLUX - 2 LAMP RECESSED CMH - CYLR- I- 20- T46U6.5 -E -ST- VOLTS -NF -WT 20 watt CM 1-i LAMP 20 watt .CMH LAMP GE - CMH2OT- U&506U6.5 _ AM1 _ AMERLUX - CYLR- 2- 20- T46U6.5 -E -WT- volts -NF -WT I'IXTURE . (2) 20 watt CMH LAMP AM2 Io 01 RECESSED DOWN LIGHT. AMERLUX GYLR- 2- 20- T46U6.5 -E -ST- VOLTS- NF -NF -WT (2) 20 watt GMH LAMP AM2F 6E - CMH2OT -U 550006.5 (2) 20 watt CMH LAMP AM2L AMERLUX - GYLR- 5- 20- T46U6.5 -E -WT- Salts -NF -WT FIXTURE (5) 20 watt CMH LAMP AM3 GE - GMH2OT- U5$06U6 5 RECESSED DOWN LIGHT. AMERLUX GYLR- 2- 20- T46U6.5 -E -ST- VOLTS- NF -NF -WT 2 LAMP RECESSED CMH FIXTURE COLUMBIA - 4X4 ROUND FLUORESCENT RECESSED - M464- 552 - ESOP- ESSUNV (5) 20 watt CMH LAMP AM3L AM1F ° (I) E Sr S3O M464 - 952 - ESOP -E15&UNV FF1 FF1L T.S.D. T.B.D. E QHE2X52T 5{UNV - ISN -SC LIGHTOLIER - 2X4 RECESSED LENSED LUMINAIRE, BALLAST: 014E2X52T8/UNV- ISN -SC, XP26VA252UNVH1 -* A LIGHTOLIER - 2X2 RECESSED FLUORESCENT, 5" DEEP, 1 CELL PARABOLIC, LOUVER, BALLAST: QHEEXE2T5UNV- 15N -SC, DPA2601LPEllUNVOK -"* QHE5X52T5UNV- ISN -EC RC2 101 ARCH LIGHTING - REC. SQ. DOWNLIGHT - LUCI- 12- 26- ST /I2O /271 LUCI- P- 26- ST/12O/211 GE - 26 WATT EFL, F26TBX &55 F26TBX &95 RD1 0 • HERA LI'HTIN6 - ARF -LED LED INCLUDED, S WATTS V0105- R- W15- RC /60-WH EX1 T EXITRONIX -- EXIT EDGE LIT - Vg02- U- W15-RC -WH EX l C 1 EXITRONIX Vg02- R- W15- RC /GC -WH EE ISOLITE - RECESSED EGRESS FIXTURE - MI- -6N -25 -LC. -UN MI- 6N- 25 -LC -UN ell EM EXITRONIX - WALL MOUNT EGRESS FIXTURE - LLgQ • LIAOHW- 6- 21- S- IN -G2 FIXTURE NOTES: . I. IPIXTURES SHALL HAVE APPROPRIATE UL LABEL, DAMP, OR WET AS REQUIRED BY LOCAL CODES. 2. FIXTURES SHALL INCLUDE ACCESSORIES FOR INSTALLATION ACCORDING TO LOCAL AND NATIONAL COPES. . 5. PRIOR TO ORDERING LIGHTING EQUIPMENT, THE CONTRACTOR SHALL VERIFY LOCATIONS AND RECESS DEPTHS. 4. LAMPS SHALL BE INSTALLED ACCORDING TO THE ATTACHED FIXTURE SCHEDULE. CONTRACTOR SHALL VERIFY FINAL VOLTAGES AND CEILING TRIM COMPATIBILITY PRIOR TO ORDERING FIXTURES. CEILING THICKNESS IN EXCESS OF 5/4" SHALL BE IDENTIFIED IN WRITING SY CONTRACTOR /ARCHITECT. . FIXTURES SHALL BE ORDERED WITH THE APPROPRIATE BALLASTS THAT HAVE UL AND GSM LABELS. BALLASTS SHALL CONFORM TO TITLE 24 REQUIREMENTS FOR PERFORMANCE, SWITCHING, AND WIRING (I.E. TANDEM). PROVIDE APPROVED FIRE -RATED ENCLOSURES FOR LIGHTING FIXTURES LOCATED IN A FIRE -RATED CEILING. q. , WALLS DIRECTLY ILLUMINATED SHALL BE INSTALLED AND FINISHED IN A MANNER TO ELIMINATE SHADOWS OR BLEMISHES (I.E. HANG DRY WALL VERTICALLY). 10. RESPONSIBILITY FOR EMERGENCY LIGHTING, TITLE 24 CALCULATIONS, AND CIRCUITING TO MEET CODE CONFORMANCE REMAINS WITH THE ARCHITECT AND ELECTRICAL ENGINEER AS REQUIRED SY LAW. . FIXTURES LOCATED IN AN INSULATED CEILING AREA, SHALL HAVE AN IC HOUSING (ELECTRICAL CONTRACTOR TO COORDINATE). S. 6. 1. &. II. 12. THE ARCHITECT AND LIGHTING DESIGNER SHALL APPROVE FIXTURE SUBSTITUTIONS PRIOR TO SIP. CONTRACTOR SHALL SUPPLY A SAMPLE AND /OR PHOTOMETRIC DATA IF REQUESTED. IF SUBSTITUTION IS REJECTED, CONTRACTOR SHALL PROVIDE SPECIFIED PRODUCT. 15. ALL FiXTURE VOLTAGES TO BE DETERMINED BY ELECTRICAL ENGINEER I. SUBMITTALS 2. INSTALLATION GENERAL NOTES REVIEWED FOR CODE COMPLIANCE NFPA 70 — NEC S ° 4 '4103 City Of Tukwila UILDING DIVISION CONTRACTOR IS TO PROVIDE COMPLETE SUBMITTALS, INCLUDING ORDER #S AND ANNOTATED CUT SHEETS FOR APPROVAL BY ARCHITECT AND LIGHTING DESIGNER PRIOR TO FIXTURE ORDER. ALL FIXTURES TO SE INSTALLED PER MANUFACTURER'S REQUIREMENTS AND IN COMPLIANCE WITH ALL APPLICABLE BUILDING CODES. LOCAL BUILDING AUTHORITIES ARE TO BE CONSULTED TO RESOLVE QUESTIONS OF COMPLIANCE. ARCHITECT IS TO BE ALERTED IN CASES WHERE COMPLIANCE REQUIRES DEVIATION FROM DESIGN DOCUMENTS. S. ADDITIONAL COMPONENTS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL COMPONENTS AS REQUIRED FOR COMPLETE INSTALLATIONS FOR ALL PIXTURES.THIS INCLUDES, BUT IS NOT LIMITED TO: MOUNTING BRACKETS, POWER PEEP FITTINGS FOR LINEAR FIXTURES AND TRACK, POWER SUPPLIES, CONNECTORS, FUSES, AND ANY OTHER COMPONENTS NOT SPECIFICALLY LISTED IN THE SPEC. BUT REQUIRED FOR A FUNCTIONING CODE- COMPLIANT INSTALLATION AND OPERATION OF FIXTURE. 4. ADDITIONAL COMPONENTS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL COMPONENTS AS REQUIRED FOR COMPLETE INSTALLATIONS FOR ALL FIXTURES.THIS INCLUDES, BUT IS NOT LIMITED TO: MOUNTING BRACKETS, POWER FEED FITTINGS FOR LINEAR FIXTURES AND TRACK, POWER SUPPLIES, CONNECTORS, FUSES, AND ANY OTHER COMPONENTS NOT SPECIFICALLY LISTED IN THE SPED BUT REQUIRED FOR A FUNCTIONING COPE - COMPLIANT INSTALLATION AND OPERATION OF FIXTURE. . 0- •G ,• 1 These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 0 0 a) OD 4 ui m 00 Uirn w w aa • • o G"w a .c m mm o u, E Lei ] Nrt iN N yeanginWIA. 111 t/9 W J CI W V W J W W H 0 Z z cci P al za. i re WAtax U./ Lil agill z yF- LAJ z apm v � 01 R v, 0o2 . ckoiseS 0 Ui Liss w is Co N E Q a. U tts a cs g g 0. 4J — C F- RECEWED AUG 21MOO PERMIT CENTEh■ DATE: 05.14.O& SHEET: SCALE: DRAWN BY: 1/4" -1' -0" STAFF E301 PROJECT No.: TMSO&OIq TELEPHONE BACKBOARD ELEVATION NT.S. NETWORK NIU T I CONNECTIONS AP0(GORP AND WIRELESS MOBILITY) MUZAG FLOOR 00 00 Pe ADT SECURITY PANEL ADT eEc,URITY SYSTEM RJ -SIX JACK FOR ADT SECURITY NOTES: .� PROVIDE GROUNDING TERMINAL BUS BAR WITH #6 GU GROUND WIRE TO SERVICE GROUNDING ELECTRODE. QUEST ENVIRONMENTAL WALLBOARD PHONE 5'0 "x5' -O "x S /q" TERMINAL BOARD. (DTP. OF 2) PROVIDE ISOLATED GROUND RECEPTACLE. PROVIDE ORANGE DEVICE WITH WHITE GOVERPLATE ENGRAVED (DPIGSAO).GNP7.' #6 GU GNP TO GROUNDING ELECTRODE LOW VOLTAGE PATHWAY SYSTEM DETAIL NQ.S. DATA VOICE HVAC CONTROL CABLING CEILING LINE 7 Ya" THREADED ROD SOUND vEGURITY NOTES: I. PROVIDE SEPARATE J -HOOK GABLE MANAGEMENT SYSTEM FOR EACH INDIVIDUAL LOW VOLTAGE SYSTEM. EACH SYSTEM TO BE INDEPENDENTLY SUSPENDED FROM STRUCTURE. 2. CONTRACTOR SHALL PROVIDE INDIVIDUAL SUPPORT ROD AND J -HOOK AT 5' -0" O.G. POR ROUTING O. EACH LOW VOLTAGE: SYSTEM. 5. PROVIDE J -HOOKS ATTACHED DIRECTLY TO STRUCTURE .IN AREAS WITH LOW CEILING HEIGHT. 4. WHERE PASSING UNDER 05 OVER DUCTWORK, TRANSITION TO. A HORIZONTAL J -HOOK SUPPORT ARRANGEMENT, MAINTAINING PROPER GABLE SPACING. NO PHYSICAL CONTACT IS ALLOWED BETWEEN LOW VOLTAGE GABLES AND DUCTWORK, PIPING, STRUCTURE, CONDUITS, LIGHTS, OTHER SYSTEM GABLES, ETC. 5. INDEPENDENTLY SUPPORT J -HOOKS PROM THE BUILDING STRUCTURE SUCH .A5 THE UNDERSIDE OF THE ROOF OR TRUSSING. PO NOT SUPPORT J -HOOKS OR THREADED RODS FROM FRAMING. ANY RODS oR J -HOOKS SUPPORTED FROM FRAMING, PIPING, DUCTWORK, ETC., SHALL BE REMOVED. AND RE- SUPPORTED AT THE EXPENSE OF THIS CONTRACTOR. RTU -2 RTU-I QSRTU CONTROLLER ROC)F LIGHTING AND Q9RTU CONTROLLER STS2 DUCT MOUNT TEMP. ' SENSOR ZT52 WALL MOUNT TEMP. SENSOR STS1 DUCT MOUNT TEMP. SENSOR ZTSI SEE NOTE #6 HVAC CONTROLS RISER NTS. DENOTES 15MS WIRING REQUIRED. PROVIDED CONDUIT ONLY AS REQUIRED I5Y GODS, JURISDICTION, LANDLORD OR QUEST. pEE NOT4 146 TYP) L (SHTINd CONTROL PANEL TSTAT TGTAT (TY q. P) OTE # SEE NOTE #2• WALL MOUNT TEMP. SENSOR SEE NOTE #I SEE NOTE #4 (TYP) 120 VA0 --W ELECTRICAL SUB- CONTRACTOR SHALL INSTALL COMPLETE BMS SYSTEM AND SHALL PROVIDE ALL WIRING STARTUP AND CHECK OUT. CONTROLLER, LOG, P.S. OTLI, OVRI, PATCH CORD, ZTS DEVICES, STS DEVICES SHALL BE FURNISHED BY OUEST FOR INSTALL BY ELECTRICAL CONTRACTOR. 1.25 "C TO DATA RACK 4" SQUARE OUTLET BOX W/ 2 -GANG MUD RING 2 x 2 MONITORS DETAIL N.T.S. SINGLE DEDICATED 20 AMP CIRCUIT HOMERUN COORDINATE LOCATION WITH OWNER'S VENDOR EIMS CONTROLLER PANEL ItG186MS LIGHTING OVERRIPE PANEL "OVRI" SEE NOTE #1 DATA ROAM BACK OF MOUSE OUTDOOR TEMPERATURE LIGHT SENSOR "OTLI" SEE NOTE #E EXTERIOR NOTES: I. MOUNT ON TELEPHONE BACKBOARD. SEE DETAIL ON THIS SHEET. 2. MOUNT ABOVE PANEL-BOARDS. 5. MECHANICAL SUB- CONTRACTOR .SHALL MOUNT SENSOR IN DUCT; ELECTRICAL SUB- CONTRACTOR SHALL PROVIDE CONDUIT /WIRING. 4. SEE SIGNAL AND HVAC PLANS FOR EXACT LOCATION OP DEVICES. 5. COORDINATE EXACT LOCATION W/ 'ARCHITECT PRIOR TO ROUGH -IN. 6. MOUNT WITHIN RTU. ALL ASSOCIATED WIRING SHALL RUN AT UNDERSIDE OF ROOF AND WITHIN OPENIN. COORDINATE WITH MECHANICAL SUB- CONTRACTOR, 3 x 3 MONITORS DETAIL N.T.S. I.25 "C TO DATA RACK 4" SQUARE OUTLET BOX I^t/ 2 -6AN6 MUD RING' COORDINATE LOCATION WITH OWNER'S VENDOR SINGLE DEDICATED 20 AMP CIRCUIT HOMERUN LOci — FOURPLEX RECEPTACLE (TYP) --REVIEWED FOR CODE COMPLIANCE NWpA 70 2Vna -•--- City Of -nuk b BuILTAQpivisioN COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as on ".architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form. arrangement and composition of spaces. and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result In cessation of construction, building seizure. and /or monetary liability. ranriFsql i >,:,2 c CV a- Vet raC rM # miC Q a) tQ .76.1 g giCE ;Z .12 tir) J Vf Fag W • �j F O Z V W Q c. uLU z w W 6 z J 0 0 mho' z 0 m N ry 01 c0 0 CO a ®' `tr c II' N at in a co •c co co z a° m m r 0 u u RECEIVED ,AUG 21 NOB PERMIT CENTER DATE: SCALE: DRAWN BY: PROJECT No.: Ob.14.O5 SHEET: I/4 =1' -0" SIAI- E302 TMSO&O I [i 00000' 0 0 0 0 0 0 0 '0 0 A n n 9-2-5 P/N QTY DESCRIPTION 150435 .. 1 Q3BMS CONTROLLER. (Q3BMS) 150211 -3 1 LIGHTING CONTROL PANEL (LCC) 300747 1 24/120 VAC DUAL POWER SUPPLY (PS1) 150745 1 OUTDOOR TEMP/LIGHT LVL (OLT1) 150677 1 OVERRIDE PNL 2- BUTTON (OVR1) 350064 -15 -- CAT5E 10' PATCH CBL, BLUE I EXT FIELD WIRING LEGEND WIRE COLOR/PAiR DEVICE CRED /1- RTU :TB3 :°+PLY TERMINAL BLOCK -I POSISITION CABLE PAIR LEGEND: RED /1 BLK/1= PAiR 1 WHT /2 BLK/2 = PAIR 2 INSTALLATION NOTE( #1): REFER TO SITE DRAWINGS FOR SPECIFIC LIGHTING LOAD CONNECTIONS, ELSE REFER TO SECTION 3.5 OF THE INSTALLATION INSTRUCTIONS LOCATED ON DRAWING BMS 1.3. 12.0" *NOTE — CABLE/WIR DESCRIPT ON TAN DA A. CABLE, 2 PAIR, 3ELDEN 20AWG,.STRND, SHLD 1441 FE B. TSTAT, 8 COND, • cOLEMA 18 AWG, SLD 5308 C. WIRE, 16 AWG HHN 0, WIRE, 14 AWG HHN E LIST (PROVIDED BY CONTRACTOR) D P NUM ACCEPTABLE C OSS BELDEN STANDARD - BELDEN 5341FE, 5341PT, & 5541PT. 6441 FE STANDARD -- ALPHA 561082002, 5610B1802, 2242C, & 6427. PLENUM — ALPHA 57632 COLEMAN ANY COMPARABLE 8 CONDUCTOR T -STAT CABLE. 55508 N/A N/A FIELD WIRING TER MIN TORQUE ALL FIELD WIRIpG TO 7 IN-LBS •IS Ill ALS 12.0 TOP 0 PNL# PNL# PNL# PNL# PNL# NL# PNL# PNL# PNL# PNL* PNL# PNL# 0 PREWIRED ® FACTORY: NEUTRAL - 14AWE /WHITE 120 VAC - 14AW6/BLAGK 6ROUNA - I4AINE /EREEN 24VAC - 20A10.16/RED 24VAG RETURN _ 20AWE/BLAGK 24V - 20A146/RED BXTERIQR LIEHTS- BRKR# BRKR# BRKR# BRKR# INTERIOR GENERAL LIGHTS #2 PRKR# BRKR# 15RKR# BRKR# INTERIOR GENERAL LIGHTS #I BRKR# BRKR# BRKR# BRKR# EXTERIOR LIGHTS (C3) OO?M M ®6 ac S.✓ v x 6 $1& JANUARY' I, 200'7 Oa K— (C_J 4 V REVIEW J Et YES . VO ai NO EMPLOYEE LIFTS (C2) O . =_° M ®6 ac S.✓ v x 6 $1& JANUARY' I, 200'7 K— P I K 4 • CUSTOMER Ld HT (Cl) C2 C . . T Mill mirmom = ■u u■■7■ ■ r- ■ Numrimr ■ 1< ■■ ■ it ■ U "MIMI ION 2'I VAG - 24 VAC (RTN) 24 V K3 K2 K1 I ■14` •i ,1 ■'i.C,11 (TG LIcHTIN6 LDAri) imii�.III INN DAMN ■C` ■m Imumum ( THHN, RED, 16 AWG, STRNP(L) 2.0 1i.0" RED -LGG, T132, 24VAG Pal, Avxn$s /A: WMT/8LU(GOM (10SI : AJX/15VA :INHT/YE'IF247 P/N 150435 Q3BMS REFER TO. INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION 120 VAC --� NEUTRAL GROUND BOTTOM P/N 130211 --3 LIGHTING CONTROL— PANEL, REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION 120 VAG SUPPLIED TO PANEL BY ELECTRICAL CONTRACTOR PNL# 15RKR# R50 /I- RTU :T154 :A) + i D /1 -GZ; 13M5111B21A }� COL K/1-05 146 TB21 B)_.I SEE DRAWING BMS 1.2 BLK/I- RTU:T04:5 II ( WHT /2- RTU:T154 0 >a--d 1--- 4mW14T /2- OSBM5:752 :0 I SPARE L4N L THHN 14A NOTE: UPON COMPLETION OF THE INSTALLATION, VERIF THE HAS BEEN INSTALLED AND HAS NETWORK CONN CTIVIT TO THE ROUTER IS ESSENTIAL FOR VERIFYING THE OPE CONTROLLERS. CONTACT QUEST CONTROLS MON TORIN COORDINATE TESTING AND VERIFICATION OF THE SYSTE PRIOR TO PUNCH —DOWN. THE MONITORING CENTER C AT (941) 723 -4130 OR (866) 799-0812. t, C NOTE. INSTALL AUMPER 0 9 IA - >2A 2A - >SA REC- 0313MS:TEO: IA Eg- K -Q3BMS 1133 :313 6RN- 05BMSTE55 :2i3 WHT- 255MS.T55115 4 SPARE COLEMAN 55305 , GOND, 18AWc5, SLP, T -STAT THHN, RED, 16 AWE, STRND RFD- c2SBMSITBI.NE6 PNL 120 VAC SUPPLIED TO PANEL BY ELECTRICAL CONTRACTOR 5i7K1s# L' N DTHHN, BLKIGRN /WHY, ' 14 AWE, STRND PS1 L( °51 :AUX /4OVA,WHT/i?Lt)(GOM — (RED -c 3BMS :TB1: .:�--- - - P511AUx/40VA,WFiT/YEI('24V) INSTALLATION NOTES( #5): PROVIDE GROUND WIRE FROM BONDED -. ELEGTRIGAL PANEL FEEDING THE 05/LCC POWER SUPPLY (PSI) 1101 V1 CI 111A 10 (Dee j)0 ip0. �JC?(- TAG TU7 C2 A2J1 4 SPARE 1.0" INSTALLATION NOTE( 44): TERMINATE t3US GABLE SHIELD TO CHASSIS GROUND AT G3BMS ONLY. CARRY AND INSULATE SHIELD DRAIN THROUGH TO EACH RTU. TAPE OFF GABLE SHIELD 'AT END OF LINE RTU ONLY. BLK /6RN/WHT, , STRND I SPARE a NV9 0 Q.. K1iTF 0� J 0 K2 K31 c) ICI • 0 • 0 Ks (L) O KS e 0 • f ( C K? T— (D CS • 9 0 Ka KS O • (E� (D p cZP x1c 0 K1l () ▪ CD ✓ CD L (D rT t_ --3 e r (1).Z) K11 — W C3 0 K1 - T- (D .0.. r- 1(1a C0 L _2 K1 ti ( 0 . 0 x1 0 0 OLIO 11 0 0 D " o0 0 0 0 0 0 o c 0 4 G v V_ 0 O h .a rr� J10 T81 0 C `1� JANUARY' I, 200'7 ®K\ P I K /7. REVIEW J YES . VO NO C2 C . . T Mill mirmom = ■u u■■7■ ■ r- ■ Numrimr ■ 1< ■■ ■ it ■ U "MIMI ION 2'I VAG - 24 VAC (RTN) 24 V K3 K2 K1 I ■14` •i ,1 ■'i.C,11 (TG LIcHTIN6 LDAri) imii�.III INN DAMN ■C` ■m Imumum ( THHN, RED, 16 AWG, STRNP(L) 2.0 1i.0" RED -LGG, T132, 24VAG Pal, Avxn$s /A: WMT/8LU(GOM (10SI : AJX/15VA :INHT/YE'IF247 P/N 150435 Q3BMS REFER TO. INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION 120 VAC --� NEUTRAL GROUND BOTTOM P/N 130211 --3 LIGHTING CONTROL— PANEL, REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION 120 VAG SUPPLIED TO PANEL BY ELECTRICAL CONTRACTOR PNL# 15RKR# R50 /I- RTU :T154 :A) + i D /1 -GZ; 13M5111B21A }� COL K/1-05 146 TB21 B)_.I SEE DRAWING BMS 1.2 BLK/I- RTU:T04:5 II ( WHT /2- RTU:T154 0 >a--d 1--- 4mW14T /2- OSBM5:752 :0 I SPARE L4N L THHN 14A NOTE: UPON COMPLETION OF THE INSTALLATION, VERIF THE HAS BEEN INSTALLED AND HAS NETWORK CONN CTIVIT TO THE ROUTER IS ESSENTIAL FOR VERIFYING THE OPE CONTROLLERS. CONTACT QUEST CONTROLS MON TORIN COORDINATE TESTING AND VERIFICATION OF THE SYSTE PRIOR TO PUNCH —DOWN. THE MONITORING CENTER C AT (941) 723 -4130 OR (866) 799-0812. t, C NOTE. INSTALL AUMPER 0 9 IA - >2A 2A - >SA REC- 0313MS:TEO: IA Eg- K -Q3BMS 1133 :313 6RN- 05BMSTE55 :2i3 WHT- 255MS.T55115 4 SPARE COLEMAN 55305 , GOND, 18AWc5, SLP, T -STAT THHN, RED, 16 AWE, STRND RFD- c2SBMSITBI.NE6 PNL 120 VAC SUPPLIED TO PANEL BY ELECTRICAL CONTRACTOR 5i7K1s# L' N DTHHN, BLKIGRN /WHY, ' 14 AWE, STRND PS1 L( °51 :AUX /4OVA,WHT/i?Lt)(GOM — (RED -c 3BMS :TB1: .:�--- - - P511AUx/40VA,WFiT/YEI('24V) INSTALLATION NOTES( #5): PROVIDE GROUND WIRE FROM BONDED -. ELEGTRIGAL PANEL FEEDING THE 05/LCC POWER SUPPLY (PSI) 1101 V1 CI 111A 10 (Dee j)0 ip0. �JC?(- TAG TU7 C2 A2J1 4 SPARE 1.0" INSTALLATION NOTE( 44): TERMINATE t3US GABLE SHIELD TO CHASSIS GROUND AT G3BMS ONLY. CARRY AND INSULATE SHIELD DRAIN THROUGH TO EACH RTU. TAPE OFF GABLE SHIELD 'AT END OF LINE RTU ONLY. BLK /6RN/WHT, , STRND I SPARE a NV9 0 Q.. K1iTF 0� J 0 K2 K31 c) ICI • 0 • 0 Ks (L) O KS e 0 • f ( C K? T— (D CS • 9 0 Ka KS O • (E� (D p cZP x1c 0 K1l () ▪ CD ✓ CD L (D rT t_ --3 e r (1).Z) K11 — W C3 0 K1 - T- (D .0.. r- 1(1a C0 L _2 K1 ti ( 0 . 0 x1 0 0 OLIO 11 0 0 D " o0 0 0 0 0 0 o c 0 4 G v V_ 0 O h .a rr� J10 T81 0 C Goo �� to OOJPJ RES 0 0 MODEM MODULE • 0 0 (7 !M 'TI ( 0 0 0 0 0 C) 0) cci) ci) 0) C' O (D 0 3 4.3 FEW 0 TRANUFORMER: 25V0c, 4594. ' AS$ 2 TRANDFORIIEti PRIMARY: CUM_ 124 - 0t:WI-OP 111949410 024104 »tau 00p2411214. 014111' PCMAC41: 12OVne on,: tl 40 iasrh wir0, Neu401 ,vhile 41re, Or7sr, 49900000. 24Vot 4OVA: WMn.5oIow (24Vhr.). W11900II)I a (GQA.11 TRANSFORMER: 24V00. 7,5w, Ct0554 TR0.213FORMCR PRLMARY CCM 120 2401 240 7r7 444 tip 'Atli R%1) at900 URf. [w4Y I00000to unuo0J1 \I(tb cops soy. INPUT ICYAF.N: 1$1Vnc only: IIrL. hyr.' o(oo.99490 .vhUa w'ra, (.1coond glrcn 905 14AI5 YQ'MPR 4 I4OIuUra4or tOn • I'ev).4 091030o1 4a 4„x444[., SEC01104.RY: 2,f0944754'k. \VUiLh, OOIOS (24Vo5, f1 WII4o1bIna(0000) • 4J $ PE@91 Dtp • 12/N 300747 24/120VAC DUAL POWER SUPPLY REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION ri.gam �liSl ,■r UHI 00090000.0000.00000 NETWORK MODULE 4000040009004000o 00600•0•0 ******** J4 F1 J0) OQ) 0 O (A . 0) O G — 0) 0 12V N1p N11 12V 1N12 I1112 G 12V 11114 11415 12V IN16 G (I) G O 0 12V mD C) (I) D1 n 0 0 C1 0 (I) +r2" 0R F4 a BELDEN 5441FE 2 PAIR, 20AWc5, STRND, SHLD (BELDEN 644IFE - FOR PLENUM) TORE. ROUTER CONNECTIVITY ATION OF THE RTU CENTER TO AT LEAST 24 HOURS BE REACHED Q3BMS tri MODEM' PORT AODOO �� 1`--'J �4hO4 Lam/ RS232 PORT E THE RNE' PORT 101 GAT 5E PATCH GABLE, BLU (SUPPLIED BY GlUEST) J 1 a 1 TAPE SHIELD (TYP.) REP /I- OSSM5: T54: INI BLK/1- Q515M5: T544 :12 LK/2 -OBE N15 :Ti34,6N� V41-1T /2 - 0515MS: T154: IN 2 8.3 OIL' 2.23" ■ I/2" NM' Knackaub BELDEN 5441FE 2 PAIR, 20AWE, STRND, SHLD (BELDEN 6441FE - FOR PLENUM) INSTALLATION NOTE( #6)• TERMINATE SENSOR CABLE SHIELDS) TO CHASSIS GROUND AT 055MS ONLY. TAPE OFF CABLE SHIELD AT SENSOR. 11J CISCO ROUTER 0 (TBD) PORT# __ PROVIDED BY OTHER MOM NEIN '?.010" 3.82" P/N 150745 OUTDOOR TEMPERATURE/ LIGHT LEVEL SENSOR REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION TAPE 5HIELe7 (TYP.) REi7 /I- Q915MS. Ti F. IN4 BLK/I- 05SMSI TES4 :12 T /2 Q3BMS: T154: INS 1.14./2- 613E3M5: T154:12 41NT16LK .)— {INT :6LK)— OVERRIDE PANEL INTERIOR LIGHTS EXTERIOR LIGHTS .SI P/N 150677 TWO BUTTON OVERRIDE PANEL REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION OVR1 INSTALLATION NOTE( #2): ** INSTALLATION CONTRACTOR IS RESPONSIBLE FOR USING CABLE /WIRE THAT EITHER MEETS OR EXCEEDS THE WIRE SPECIFIED IN THIS DRAWING. ANY DEVIATIONS FROM THE WIRE SPECIFIED COULD AFFECT THE PROPER OPERATION OF THE SYSTEM. . INSTALLATION NOTE( #3): ** CONTACT T- MOBILE PROJECT MANAGER IF THERE ARE MORE THAN TWO HVAC UNITS TO REQUEST ADDITIONAL RTU CONTROLLERS OR TO REPLACE DAMAGED OR MISSING PARTS. THE LIGHTING AND HVAC CONTROLS CONSIST OF A QUEST ENERGY MANAGEMENT SYSTEM FURNISHED BY QUEST FOR THE COMPLETE INSTALLATION BY THE ELECTRICAL SUBCONTRACTOR. INFORMATION SHOWN ON ELECTRICAL - SHEETS E -400, E-401 AND E -402 ARE TO ILLUSTRATE THE SCOPE OF WORK,. HOWEVER, PRIOR TO ROUGH -IN THE ELECTRICAL SUB - CONTRACTOR SHALL OBTAIN THE LATEST QUEST PLANS FOR REFERENCE AND PROVIDE A COMPLETE INSTALL. COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. to 0 00 co QL.n oo w M m re TNIt U mai 034-' m o VI N € as r N h�- N Co 2 to co • Rs 0 w 0. A u .c (DI s— 0 CU RI g :97) Eimmi cs° z tii 1, F+1 480 998 7223 RECEIVED AUG 2 1 2000 PERMIT (rnrrl DATE: 0e,.14.05 SHEET: SCALE: . DRAWN BY: SrAr E 4OO PROJECT No.: 1/4" ;i1'-0" TMBOBOI0i JANUARY' I, 200'7 REVIEW J YES . NO PROGRA 1 I EXT OCCUPIED ILG] WITCH ENTER q 1 ca 1 Ia Goo �� to OOJPJ RES 0 0 MODEM MODULE • 0 0 (7 !M 'TI ( 0 0 0 0 0 C) 0) cci) ci) 0) C' O (D 0 3 4.3 FEW 0 TRANUFORMER: 25V0c, 4594. ' AS$ 2 TRANDFORIIEti PRIMARY: CUM_ 124 - 0t:WI-OP 111949410 024104 »tau 00p2411214. 014111' PCMAC41: 12OVne on,: tl 40 iasrh wir0, Neu401 ,vhile 41re, Or7sr, 49900000. 24Vot 4OVA: WMn.5oIow (24Vhr.). W11900II)I a (GQA.11 TRANSFORMER: 24V00. 7,5w, Ct0554 TR0.213FORMCR PRLMARY CCM 120 2401 240 7r7 444 tip 'Atli R%1) at900 URf. [w4Y I00000to unuo0J1 \I(tb cops soy. INPUT ICYAF.N: 1$1Vnc only: IIrL. hyr.' o(oo.99490 .vhUa w'ra, (.1coond glrcn 905 14AI5 YQ'MPR 4 I4OIuUra4or tOn • I'ev).4 091030o1 4a 4„x444[., SEC01104.RY: 2,f0944754'k. \VUiLh, OOIOS (24Vo5, f1 WII4o1bIna(0000) • 4J $ PE@91 Dtp • 12/N 300747 24/120VAC DUAL POWER SUPPLY REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION ri.gam �liSl ,■r UHI 00090000.0000.00000 NETWORK MODULE 4000040009004000o 00600•0•0 ******** J4 F1 J0) OQ) 0 O (A . 0) O G — 0) 0 12V N1p N11 12V 1N12 I1112 G 12V 11114 11415 12V IN16 G (I) G O 0 12V mD C) (I) D1 n 0 0 C1 0 (I) +r2" 0R F4 a BELDEN 5441FE 2 PAIR, 20AWc5, STRND, SHLD (BELDEN 644IFE - FOR PLENUM) TORE. ROUTER CONNECTIVITY ATION OF THE RTU CENTER TO AT LEAST 24 HOURS BE REACHED Q3BMS tri MODEM' PORT AODOO �� 1`--'J �4hO4 Lam/ RS232 PORT E THE RNE' PORT 101 GAT 5E PATCH GABLE, BLU (SUPPLIED BY GlUEST) J 1 a 1 TAPE SHIELD (TYP.) REP /I- OSSM5: T54: INI BLK/1- Q515M5: T544 :12 LK/2 -OBE N15 :Ti34,6N� V41-1T /2 - 0515MS: T154: IN 2 8.3 OIL' 2.23" ■ I/2" NM' Knackaub BELDEN 5441FE 2 PAIR, 20AWE, STRND, SHLD (BELDEN 6441FE - FOR PLENUM) INSTALLATION NOTE( #6)• TERMINATE SENSOR CABLE SHIELDS) TO CHASSIS GROUND AT 055MS ONLY. TAPE OFF CABLE SHIELD AT SENSOR. 11J CISCO ROUTER 0 (TBD) PORT# __ PROVIDED BY OTHER MOM NEIN '?.010" 3.82" P/N 150745 OUTDOOR TEMPERATURE/ LIGHT LEVEL SENSOR REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION TAPE 5HIELe7 (TYP.) REi7 /I- Q915MS. Ti F. IN4 BLK/I- 05SMSI TES4 :12 T /2 Q3BMS: T154: INS 1.14./2- 613E3M5: T154:12 41NT16LK .)— {INT :6LK)— OVERRIDE PANEL INTERIOR LIGHTS EXTERIOR LIGHTS .SI P/N 150677 TWO BUTTON OVERRIDE PANEL REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING LOCATION OVR1 INSTALLATION NOTE( #2): ** INSTALLATION CONTRACTOR IS RESPONSIBLE FOR USING CABLE /WIRE THAT EITHER MEETS OR EXCEEDS THE WIRE SPECIFIED IN THIS DRAWING. ANY DEVIATIONS FROM THE WIRE SPECIFIED COULD AFFECT THE PROPER OPERATION OF THE SYSTEM. . INSTALLATION NOTE( #3): ** CONTACT T- MOBILE PROJECT MANAGER IF THERE ARE MORE THAN TWO HVAC UNITS TO REQUEST ADDITIONAL RTU CONTROLLERS OR TO REPLACE DAMAGED OR MISSING PARTS. THE LIGHTING AND HVAC CONTROLS CONSIST OF A QUEST ENERGY MANAGEMENT SYSTEM FURNISHED BY QUEST FOR THE COMPLETE INSTALLATION BY THE ELECTRICAL SUBCONTRACTOR. INFORMATION SHOWN ON ELECTRICAL - SHEETS E -400, E-401 AND E -402 ARE TO ILLUSTRATE THE SCOPE OF WORK,. HOWEVER, PRIOR TO ROUGH -IN THE ELECTRICAL SUB - CONTRACTOR SHALL OBTAIN THE LATEST QUEST PLANS FOR REFERENCE AND PROVIDE A COMPLETE INSTALL. COPYRIGHT NOTICE: These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. to 0 00 co QL.n oo w M m re TNIt U mai 034-' m o VI N € as r N h�- N Co 2 to co • Rs 0 w 0. A u .c (DI s— 0 CU RI g :97) Eimmi cs° z tii 1, F+1 480 998 7223 RECEIVED AUG 2 1 2000 PERMIT (rnrrl DATE: 0e,.14.05 SHEET: SCALE: . DRAWN BY: SrAr E 4OO PROJECT No.: 1/4" ;i1'-0" TMBOBOI0i O a 0 To Circuit Breaker Panel (120V single phase) 1. Mounting the Q3BMS: Power Supply 24VAC 2 -Stage (Quest P/N 300747) Q3BMS (Quest P/N 150435) 1.1 Location 1.1.1 Q3 mounting location, to ensure uniformity throughout the T- Mobile sites the Q3 will be mounted eye level on. the .Telco equipment board provided as identified in site drawings. Usually this is in maintenance or other non - public location near the circuit breaker panel. Ensure the area is well lit and free from excessive vibration and moisture. Sufficient area around the system must allow for routing of conduit and cable. GROUNDING STUDS TOP MOUNTING HOLES O 0 by • irs 03SM$ (3.1 03105107 ewe unw iO 1E1 FSCEM 0 BB EMU 0 •D I. W M a BOTTOM MOUNTING HOLES 1.2 Securing to the wall 1.2.1 Using appropriate hardware ( #8 x 3/4 pan head wood screw or equivalent) fix the top mounting hardware to wall approximately 70" above the floor 9.5" apart and level. Remove cover from the Q3 and slip the Q3 onto the top mounting hardware and slide down until it stops. Install the bottom mounting hardware. 1.2.2 Using terminal lug, run 16 awg (or larger) ground wire from Q3 ground stud to building ground and connect using appropriate hardware. Select most convenient ground stub, all grounding studs and ground bus are common. 3 • emove these two screws and carefully tilt the ower supply down and pull it away from the ack panel mounting plate I/0" L 0 1 Mount back panel securely to wall using these sholes o� . 2. Power Supply Ins allot on: . 2.1 Mounting Loco ion 2.1.1 Locate th power supply on the left side of the Q3 as per installation drawings. 2.1.2 Attention must be paid to the location of the power supply when it comes to protection f sw tches. Ensure inadvertent traffic near or by the power supply will not accidentally switch the power supply off. . 2.2 Mounting the power supply 2.2,1 Remove t o screws identified in diagram, tilt power supply down and slide off plate . 2.2.2 Ensure 1/8" gap is maintained between wall and plate to allow for power supply tangs to slip into . tee slots. 2.2.3 Make power connections using appropriate wire nuts or insulated crimps. Power supply pircuit breaker is designated in site drawings. 4OVA Output Q3BMS 120VAC. Input 75VA Output to LCC White - Neutral . Black - 129VAC WHT /YEL - 24VAC Green -- Ground WHT /BLU - COM • WHT /YEL 2fVAC WHT /BLU - COM 2.2.4 Slip tang intc tee _ slots and tilt power supply up into place. Return retaining screws and tighten. 2.3. Wiring for 12 vac, use 20a single phase breaker as identified in site drawings. Connect to the power supply using appropriate wire. 2.4 Low voltage wiring to power Q3, connect low voltage 24vac power from power supply 40 VA output to the Q3 input power connector using 16awg stranded wire. 2.5 Label power supply with circuit breaker panel designation and breaker. number.. 2.6 Turn on circuit breaker and power supply switches, . verify. Q3 is powered up and LCD display is I t. . 3.. LCC installation: 3.1 Location 3.1.1 As iden hardware. Q ( ) TOP MOUNTING HOLES o- sR uu • in 0 il,l c �i Qtly iillEf011 ii : oill "maim 0 0 I/0" L 0 1 Mount back panel securely to wall using these sholes o� . 2. Power Supply Ins allot on: . 2.1 Mounting Loco ion 2.1.1 Locate th power supply on the left side of the Q3 as per installation drawings. 2.1.2 Attention must be paid to the location of the power supply when it comes to protection f sw tches. Ensure inadvertent traffic near or by the power supply will not accidentally switch the power supply off. . 2.2 Mounting the power supply 2.2,1 Remove t o screws identified in diagram, tilt power supply down and slide off plate . 2.2.2 Ensure 1/8" gap is maintained between wall and plate to allow for power supply tangs to slip into . tee slots. 2.2.3 Make power connections using appropriate wire nuts or insulated crimps. Power supply pircuit breaker is designated in site drawings. 4OVA Output Q3BMS 120VAC. Input 75VA Output to LCC White - Neutral . Black - 129VAC WHT /YEL - 24VAC Green -- Ground WHT /BLU - COM • WHT /YEL 2fVAC WHT /BLU - COM 2.2.4 Slip tang intc tee _ slots and tilt power supply up into place. Return retaining screws and tighten. 2.3. Wiring for 12 vac, use 20a single phase breaker as identified in site drawings. Connect to the power supply using appropriate wire. 2.4 Low voltage wiring to power Q3, connect low voltage 24vac power from power supply 40 VA output to the Q3 input power connector using 16awg stranded wire. 2.5 Label power supply with circuit breaker panel designation and breaker. number.. 2.6 Turn on circuit breaker and power supply switches, . verify. Q3 is powered up and LCD display is I t. . 3.. LCC installation: 3.1 Location 3.1.1 As iden hardware. ified in site drawings. Remove cover, mount LCC using appropriate 3.2 Powering LC(p fro 120v circuit 3.2.1 A .20a single phase circuit breaker is identified in the . site drawings. Connect to the 120vac feed from the circuit breaker to TB2 of the LCC using appropriate wire. 134VA.6 I TO 24V Prot SUPPLY j74VAG orN) I 124V I TO'AS6MS evn5vi •xx IKa 1 To aaoMe OUTPUT 4XX 1y 1 TO AeeMS ourw1 +rxx IKI I TO OSSMIS OUTPUT •xX TO 34V rpm suriet -Y Gannecting Low Voltage control to LGG II Connecting 4,ine Voltage to LCC I Extertor LI -h Exterior Von Typical LCC connection to serviced circuits check site drawings for specific connections Interior Genteel LIghte e2 Exhaust t'on (Lc.) Employee Lights (L64,2) Interior Gentrol LItite "I O 0 0 0 0 6. RTU Installation - the RTU installation consists of the RTU, a Supply duct sensor, and a Zone temperature sensor with adjustment 61 The RTU controller mounts inside the roof top HVAC unit. For split systems mount the RTU controller in the Fan Coil Unit. v 6.1.1 Separate the RTU controller from the snap trek. a 6.1.2 Mount Snap Trak . 6.1.3 Insert RTU Gustomar Light. (LGGI) Interior Ascent Licehte 0 0 0 0 0 6.2 Connect Power to RTU G2 6.2.1 Check jumper J1A and J1 B for HVAC power 6.2.2 Connect C and R to the HVAC 24vac. 6.2.3 Check that the RTU LEDs light and begin cycling between Zone & Sup. 6.3 Installation of supply air sensor (QUEST PN 300199) 6.31 Select an appropriate location on the supply duct close to the air handler. 6.3.2 If the area iii insulated, peel back the insulation until an area the size of the probe box is clear. 6.3.3 Drill a small hole into the duct large enough to insert the probe into the duct. . . . 6.3.4 Secure the probe box using sheet metal screws or appropriate hardware. . 6.3.5 The sensor is not polarity sensitive so connect one lead: from the supply sensor to the + of the RTU .SPLY input and the other to the - of the RTU SPLY input. The recommended wiring is 20 AWG twisted shielded pair. 3..3 Label LCC with circuit breaker panel designation and breaker number. 3.4 Connecting Line Side 3.4.1 Connect dedicated circuits to line side of contactor across from the load connection. The contactors can be oriented either direction, check contactor connection designations (L -line, T- load). 3.5 Connect Load Side 3.5,1 Connect Customer lighting circuits to Contactor 1 = customer lights. 50% of sales floor down lights + accent lights.. Up to four individual circuits. 3,5.2 Connect Employee lighting circuits to Contactor 2 = employee lights - office lights, 50% sales (minus night lights) and bathroom exhaust fans. Bathroom exhaust fans, can be controlled by additional switches downstream, the feed will be controlled to ensure the fans are not running after the store is closed. If there is only one fan, wire directly and the Q3 will turn the fan on and off when scheduled. Up to four individual circuits. 3.5.3 Connect Exterior lighting circuits. to Contactor 3 = exterior lights - all exterior sign, soffit and building ckts. Up to four individual circuits. 3.5.4 Emergency lights are not , controlled by the LCC, check site drawings. 3.6 Wire of low voltage control to Q3 using 1 5awg TSTAT cable. 4. Override Buttons: 4.1 Install Override Button (QUEST PN 150677 ) at location identified in site drawings. 4.1.1. Location -°- Typically mounted near the manager's office or a light switch. 4.2 Connect to Q3 using 2 pair .20 awg shielded cable. . Light Level Sensor 2 Pair 20 elwS Fuck to C!r 9BM9 outside Temperature Sensor 5. Light Level & Outside Air Sensor: . 5:1 Location: See site drawings for mounting location 5.1.1 Mounting location considerations . 5.1.1.1 North facing exterior wall. 5.1.1.2 Avoid locating the OA temperature sensor near windows, doors, louvers, exhaust -air discharges, or other sources that will influence the temperature 5.1.1.3 Away from exterior lighting 5.2 Connect to Q3 using 2 pair 20 awg shielded cable per the site drawings. VIA* rCIO 9 ve Ensure Jumpers J1A and J1B are connecting the top set of pins. II \t 41f1 Up unc _o Connect the C & .R Power to the HVAC 24VAC 6.4 Zone Sensor 6.4.1 Mount zone sensor in store according to drawing. If location is not identified, select an area out of direct sunlight and away from HVAC duct airflow, but near the return air grille. Installation locations should be selected to avoid the effects of exterior wall- surface temperatures, solar radiation from windows, and heating or cooling sources such as heating convectors or air diffusers. Consideration should be given to locations of furniture and equipment, especially office copiers, light dimming switches, and other heat producing equipment. Sensor should be mounted at a height accessible by staff to adjust temperature settings. 6.4.2 Connect zone sensor to Zone Temperature Sensor w /Slide RTU using 2 pair 20awg shielded cable. Connect the Zone + and to the RTU Zone + and -, Connect the SET on the Zone sensor to the ADJ ' on the RTU. This connection is not polarity sensitive. 6.4.3 If either the Zone or Supply sensors are not wired correctly an error message will be displayed. on RTU controller. If the display "SSE" there is a short in the line or if there is an open in the line the display will read "OSE ".. 6.5 Setting of address switch for RTU. 6.5.1 When only one RTU is installed. 6.5.1.1 Ensure SW1 -6 &7 and . SW2 -1 &3 are set to on. 6.5.2 When a additional RTU's are . installed 6.5.2.1 Follow the above instruction on the 1st RTU 6.5.2.2 On the second RTU, move switch 4 on switch block . SW1 up to the on position. 6.5.2.3 On the third RTU, move switch 3 on switch block SW1 up to the on position and switch 6 & 7 to the off position. Adjust IRTU 7. Communications Bus: 7.1 Wiring from Q3 to RTU 7.1.1 Using 2 pair 20 awg shielded connect the A terminal on the Q3 to the A terminal on the RTU. Connect the B terminal on the Q3 to the B terminal on the RTU and connect the C terminal on the Q3 to the C terminal on the RTU. 7.1..2 Terminate the shield at the Q3 chassis only, 7.2 Wiring from RTU to RTU 7.2.1 Daisy chain the bus connections from RTU 1 to RTU 2. 7.2.2 Carry the shield wire through ensuring it is insulated from ground. Cut, tape, and insulate the shield wire on the last RTU. 7.3 End of line resistor 7.3.1 On the last RTU connected, or if there is only one RTU board, ensure jumper J5 is set 1 -3 and 2-4. For intermediate RTU boards, leave the jumpers off. Supply Duct Temperature Sensor SW1 -6 &7 ON, SW2 -1 &3 ON (0' I I 0110t1060 EtiblO00110 32 When only one RTU is installed SW1- 0p774,6 &`7q7,. ON, S9�yW2- 1&113, ON 9M1 ati OU Y I1l1YLIY YYYY n lu 114 Settings on the second RTU SW1- 3 ON. SW2 -1 &3 ON 641 sea Settings on the third RTU Jumpers installed between pins 1 - 3 and 2 - 4 for the last. RTU on the BUS or if only one RTU is used 11111( 111111( RC C. 0 A BBC BUS 8. Ethernet (CATS) Connection: 8.1 Connect the supplied Ethernet cable to the RJ45 connector on the bottom of the Q3. Connect the other end to the store's router in the assigned spot. If the router is not present then route the cable to the area where the router will be installed and label the cable. . 9. Start up and Checkout: 9.1 Ensure the Q3 and the RTU has power. 9.2 Refer to : T- Mobile NSC Verification Check List 9.3 Contact Quest Controls after the installation is complete to setup an appointment for store checkout at least 1 day prior to the date. Allow approximately 1 hour to complete the system checkout with Quest. This assumes that a network connection can be established with the system. WS 1 THE LIGHTING. AND HVAC CONTROLS CONSIST OF A QUEST ENERGY MANAGEMENT SYSTEM FURNISHED BY QUEST FOR. THE COMPLETE INSTALLATION BY THE ELECTRICAL SUBCONTRACTOR.. INFORMATION SHOWN ON ELECTRICAL SHEETS E -400, E -401 AND E -402 ARE TO ILLUSTRATE THE SCOPE OF WORK. HOWEVER, PRIOR TO ROUGH -I• THE ELECTRICAL SUB - CONTRACTOR SHALL OBTAIN THE LATEST QUEST PLANS FOR REFERENCE AND PROVIDE A COMPLETE INSTALL. COPYRIGHT NOTICCI These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorised use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 11 Oa 7713 :04! 113 CX) CV ld.+ o as 76 g IIII co !!!! ■3L QUEST CONTROLS u ws t-i14 of' grit aW w a. MNWN 0 P. z 0 m Let 001 0 r a; 0 N co 0 0 0 re In ,n c L °u, oa,�� CI) ECENNED AUG 21 NOD PERMIT CENTEb DATE: 08.14.0 SHEET: SCALE: DRAWN BY: 1/4" - I' -O" STAFF E401 PROJECT No.: TMB0801 a © TOP MOUNTING HOLES o- uu • in U n il,l c �i Qtly iillEf011 ii : oill "maim iii a . lfffl _� mirmill _ 0 ca cs c.i i i' .., ,_. I h_ 0 -. 11111 K3 ICS KI 0 _o - -� I ...(� Y11 aria` ^� MI- mom! U wJcioni i,,, U,i ll , , . - 0 ' �q BOTTOM MOUNTING HOLES ified in site drawings. Remove cover, mount LCC using appropriate 3.2 Powering LC(p fro 120v circuit 3.2.1 A .20a single phase circuit breaker is identified in the . site drawings. Connect to the 120vac feed from the circuit breaker to TB2 of the LCC using appropriate wire. 134VA.6 I TO 24V Prot SUPPLY j74VAG orN) I 124V I TO'AS6MS evn5vi •xx IKa 1 To aaoMe OUTPUT 4XX 1y 1 TO AeeMS ourw1 +rxx IKI I TO OSSMIS OUTPUT •xX TO 34V rpm suriet -Y Gannecting Low Voltage control to LGG II Connecting 4,ine Voltage to LCC I Extertor LI -h Exterior Von Typical LCC connection to serviced circuits check site drawings for specific connections Interior Genteel LIghte e2 Exhaust t'on (Lc.) Employee Lights (L64,2) Interior Gentrol LItite "I O 0 0 0 0 6. RTU Installation - the RTU installation consists of the RTU, a Supply duct sensor, and a Zone temperature sensor with adjustment 61 The RTU controller mounts inside the roof top HVAC unit. For split systems mount the RTU controller in the Fan Coil Unit. v 6.1.1 Separate the RTU controller from the snap trek. a 6.1.2 Mount Snap Trak . 6.1.3 Insert RTU Gustomar Light. (LGGI) Interior Ascent Licehte 0 0 0 0 0 6.2 Connect Power to RTU G2 6.2.1 Check jumper J1A and J1 B for HVAC power 6.2.2 Connect C and R to the HVAC 24vac. 6.2.3 Check that the RTU LEDs light and begin cycling between Zone & Sup. 6.3 Installation of supply air sensor (QUEST PN 300199) 6.31 Select an appropriate location on the supply duct close to the air handler. 6.3.2 If the area iii insulated, peel back the insulation until an area the size of the probe box is clear. 6.3.3 Drill a small hole into the duct large enough to insert the probe into the duct. . . . 6.3.4 Secure the probe box using sheet metal screws or appropriate hardware. . 6.3.5 The sensor is not polarity sensitive so connect one lead: from the supply sensor to the + of the RTU .SPLY input and the other to the - of the RTU SPLY input. The recommended wiring is 20 AWG twisted shielded pair. 3..3 Label LCC with circuit breaker panel designation and breaker number. 3.4 Connecting Line Side 3.4.1 Connect dedicated circuits to line side of contactor across from the load connection. The contactors can be oriented either direction, check contactor connection designations (L -line, T- load). 3.5 Connect Load Side 3.5,1 Connect Customer lighting circuits to Contactor 1 = customer lights. 50% of sales floor down lights + accent lights.. Up to four individual circuits. 3,5.2 Connect Employee lighting circuits to Contactor 2 = employee lights - office lights, 50% sales (minus night lights) and bathroom exhaust fans. Bathroom exhaust fans, can be controlled by additional switches downstream, the feed will be controlled to ensure the fans are not running after the store is closed. If there is only one fan, wire directly and the Q3 will turn the fan on and off when scheduled. Up to four individual circuits. 3.5.3 Connect Exterior lighting circuits. to Contactor 3 = exterior lights - all exterior sign, soffit and building ckts. Up to four individual circuits. 3.5.4 Emergency lights are not , controlled by the LCC, check site drawings. 3.6 Wire of low voltage control to Q3 using 1 5awg TSTAT cable. 4. Override Buttons: 4.1 Install Override Button (QUEST PN 150677 ) at location identified in site drawings. 4.1.1. Location -°- Typically mounted near the manager's office or a light switch. 4.2 Connect to Q3 using 2 pair .20 awg shielded cable. . Light Level Sensor 2 Pair 20 elwS Fuck to C!r 9BM9 outside Temperature Sensor 5. Light Level & Outside Air Sensor: . 5:1 Location: See site drawings for mounting location 5.1.1 Mounting location considerations . 5.1.1.1 North facing exterior wall. 5.1.1.2 Avoid locating the OA temperature sensor near windows, doors, louvers, exhaust -air discharges, or other sources that will influence the temperature 5.1.1.3 Away from exterior lighting 5.2 Connect to Q3 using 2 pair 20 awg shielded cable per the site drawings. VIA* rCIO 9 ve Ensure Jumpers J1A and J1B are connecting the top set of pins. II \t 41f1 Up unc _o Connect the C & .R Power to the HVAC 24VAC 6.4 Zone Sensor 6.4.1 Mount zone sensor in store according to drawing. If location is not identified, select an area out of direct sunlight and away from HVAC duct airflow, but near the return air grille. Installation locations should be selected to avoid the effects of exterior wall- surface temperatures, solar radiation from windows, and heating or cooling sources such as heating convectors or air diffusers. Consideration should be given to locations of furniture and equipment, especially office copiers, light dimming switches, and other heat producing equipment. Sensor should be mounted at a height accessible by staff to adjust temperature settings. 6.4.2 Connect zone sensor to Zone Temperature Sensor w /Slide RTU using 2 pair 20awg shielded cable. Connect the Zone + and to the RTU Zone + and -, Connect the SET on the Zone sensor to the ADJ ' on the RTU. This connection is not polarity sensitive. 6.4.3 If either the Zone or Supply sensors are not wired correctly an error message will be displayed. on RTU controller. If the display "SSE" there is a short in the line or if there is an open in the line the display will read "OSE ".. 6.5 Setting of address switch for RTU. 6.5.1 When only one RTU is installed. 6.5.1.1 Ensure SW1 -6 &7 and . SW2 -1 &3 are set to on. 6.5.2 When a additional RTU's are . installed 6.5.2.1 Follow the above instruction on the 1st RTU 6.5.2.2 On the second RTU, move switch 4 on switch block . SW1 up to the on position. 6.5.2.3 On the third RTU, move switch 3 on switch block SW1 up to the on position and switch 6 & 7 to the off position. Adjust IRTU 7. Communications Bus: 7.1 Wiring from Q3 to RTU 7.1.1 Using 2 pair 20 awg shielded connect the A terminal on the Q3 to the A terminal on the RTU. Connect the B terminal on the Q3 to the B terminal on the RTU and connect the C terminal on the Q3 to the C terminal on the RTU. 7.1..2 Terminate the shield at the Q3 chassis only, 7.2 Wiring from RTU to RTU 7.2.1 Daisy chain the bus connections from RTU 1 to RTU 2. 7.2.2 Carry the shield wire through ensuring it is insulated from ground. Cut, tape, and insulate the shield wire on the last RTU. 7.3 End of line resistor 7.3.1 On the last RTU connected, or if there is only one RTU board, ensure jumper J5 is set 1 -3 and 2-4. For intermediate RTU boards, leave the jumpers off. Supply Duct Temperature Sensor SW1 -6 &7 ON, SW2 -1 &3 ON (0' I I 0110t1060 EtiblO00110 32 When only one RTU is installed SW1- 0p774,6 &`7q7,. ON, S9�yW2- 1&113, ON 9M1 ati OU Y I1l1YLIY YYYY n lu 114 Settings on the second RTU SW1- 3 ON. SW2 -1 &3 ON 641 sea Settings on the third RTU Jumpers installed between pins 1 - 3 and 2 - 4 for the last. RTU on the BUS or if only one RTU is used 11111( 111111( RC C. 0 A BBC BUS 8. Ethernet (CATS) Connection: 8.1 Connect the supplied Ethernet cable to the RJ45 connector on the bottom of the Q3. Connect the other end to the store's router in the assigned spot. If the router is not present then route the cable to the area where the router will be installed and label the cable. . 9. Start up and Checkout: 9.1 Ensure the Q3 and the RTU has power. 9.2 Refer to : T- Mobile NSC Verification Check List 9.3 Contact Quest Controls after the installation is complete to setup an appointment for store checkout at least 1 day prior to the date. Allow approximately 1 hour to complete the system checkout with Quest. This assumes that a network connection can be established with the system. WS 1 THE LIGHTING. AND HVAC CONTROLS CONSIST OF A QUEST ENERGY MANAGEMENT SYSTEM FURNISHED BY QUEST FOR. THE COMPLETE INSTALLATION BY THE ELECTRICAL SUBCONTRACTOR.. INFORMATION SHOWN ON ELECTRICAL SHEETS E -400, E -401 AND E -402 ARE TO ILLUSTRATE THE SCOPE OF WORK. HOWEVER, PRIOR TO ROUGH -I• THE ELECTRICAL SUB - CONTRACTOR SHALL OBTAIN THE LATEST QUEST PLANS FOR REFERENCE AND PROVIDE A COMPLETE INSTALL. COPYRIGHT NOTICCI These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorised use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 11 Oa 7713 :04! 113 CX) CV ld.+ o as 76 g IIII co !!!! ■3L QUEST CONTROLS u ws t-i14 of' grit aW w a. MNWN 0 P. z 0 m Let 001 0 r a; 0 N co 0 0 0 re In ,n c L °u, oa,�� CI) ECENNED AUG 21 NOD PERMIT CENTEb DATE: 08.14.0 SHEET: SCALE: DRAWN BY: 1/4" - I' -O" STAFF E401 PROJECT No.: TMB0801 a INSTALLATION NOTE( #1) - RTU CONFIGURATION: *PRIOR TO TURN UP SET RTU MODULE BUS ADDRESS. . RTU #1 SALES AREA - SW1 1 -8 OFF OFF OFF OFF OFF ON ON OFF SW2 1 -8 ON OFF ON OFF OFF OFF *OFF *OFF SW1 ON OFF r l IW2 4 Jk SEE NO1E RTU #2 EMPLOYEE AREA - SW1 1 -8 OFF OFF OFF ON OFF ON ON OFF SW2 1 -8 ON OFF ON OFF OFF OFF *OFF *OFF SWI ON OFF r SW2 *SEE NOTE. RTU #3 SERVER ROOM - SW1 1 -8 OFF OFF ON OFF OFF OFF OFF OFF SW2 1 -8 ON OFF ON OFF OFF OFF *OFF *OFF SW1 t)N OFF Sw2 , L • SEE NOTE *NOTE - TYPE SWITCH SETTINGS FOR HVAC HYPE SW2.7 SW2.8 DESCRIPTION STANDARD OFF AC (DX) HEAT PUMP OFF (HP) HEAT PUMP ON (H2) GAS HEAT (GH) OFF STANDARD Dj( HVAC WITH AUX. HEAT ON COMPRESSOR (Y1) & REVERSING VALVE (W1) ARE "ENERG ZED" WHEN CALL FOR STAGE 1 HEAT OFF COMPRESSOR (Y1) IS "ENERGIZED" 84 . REVERSING VALVE (W1) IS "DE— ENERGIZED" WHEN CALL FOR STAGE 1 HEAT ON ON STAGE 1 HEAT (W ) NOT — INTERLOCKED WITH FAN (G). ASSUMES THE HVAC UNIT INTERNALLY WILL TURN ON FAN (G) BASED QN SUPPLY TEMPERATURE. . INSTALLATION NOTE( #2): . ON THE LAST RTU CONNECTED, OR IF THERE IS ONIrY ONE RTU BOARD, ENSURE JUMPER. J5. IS SET 1 -3' & 2 -4. FOR INTERMEDIATE RTU BOARDS, LEAVE JUMPERS OFF. *NOTE _ CABLE /WIRE LIST (PROVIDED BY CONTRACTOR) ji DESCRIPTION A. CABLE, 2 PAIR, 20AWG, STRND, SHLD B. TSTAT, 8 GOND, 18 AWG, SLD C. WIRE, 16 AWG. D. WIRE, 14 AWG INSTALLATION NOTE( #3): TERMINATE BUS CABLE SHIELD(S) TO CHASSIS GROUND AT Q3BMS ONLY. CARRY AND INSULATE SHIELD DRAIN THROUGH TO EACH RTU. TAPE OFF CABLE SHIELD AT END OF L NE RTU. n 1 ( RED/1 -RTU:TB4:A SEE DRAWING BvIS 1.1 BLK 1 / - Q3BMS :TB2: :B Ii --- ( BLK/1 WHT /2 -Q3BMS :TB2 :C WHT /2- RTU:TB4:C ) - -- 1 SPARE P/N 300199 - 8" (SUPPLY) DUCT MNT TEMPERATURE SENSOR BELL BOX THERMISTOR W /P /N 150744 RED /1- Q3BMS :TB2 :A 4.3c;iit 5,50" l INSTALLATION NOTE(fl5): REFER TO INSTALLATION INSTRUCTIONS FOR PROPER MOUNTING OF EQUIPMENT. STS1 ___,,c.„ 8 fii .2.81 2:.00' TYPICAL FOR EACH HVAC SYSTEM CABLE LEGEND: RED /1 BLK /1 = PAIR 1 WHT /2 BLK /2 = PAIR. 2 BELDEN 5441FE 2 PAIR, 20AWG, STRND, SHLD (BELDEN 6441FE -- FOR PLENUM) INSTALLATION NOTE( #4): TERMINAtE SENSOR CABLE SHIELD(S) TO GROUND AT RTU ONLY. . TAPE OFF CABLE SHIELD AT SENSOR. WHT) -J BLK /1- RTU :TB3: +SPLY WHT) RED /1 -RTU :TB3: -SPLY -' 2 SPARE . TAPE SHIELD (TYP.) !If7===lf:! STANDARD BELDEN 5441 FE COLEMAN 55308 THHN THHN PLENUM BELDEN 6441 FE COLEMAN 55508 N/A N/A ACCEPTABLE CROSS STANDARD — BELDEN 5341FE, 5341PT, & 5541PT. STANDARD -- ALPHA 5610E12002, 561081802,. 2242C, & 6427. PLENUM — ALPHA 57632 ANY COMPARABLE 8 CONDUCTOR.T —STAT CABLE. NOTE . BUS CABLE TO RTU #2 IF PRESENT. RED/1 -RTU. 1 :TB4:A ) (BLK /1- RTU.1:TB4:B) WHT /2- RTU. 1:TB4 :C) BELDEN 5441 FE 2 PAIR, 20AWG, STRND, SHLD (BELDEN 6441FE — FOR PLENUM) P/N 150744 - Q3RTU CONTROLLER (RTU1) 6).0" {RED /1- RTU.2:TB4:A (BLK/1 -RTU.2:TB4:B WHT /2- RTU.2:TB4:C 1 SPARE TAPE SHIELD (TYP.) INSTALLATION NOTE(# O 0 6 0 O 9 CUR OUT - RESET eCJ 1-° 5WJ ° J2 COLD START a i T R 0 0._ (� 0 CD BUS ( 4.50" ZTS1 Le 001! U if O 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 00 JTE9t Quest Controls k TU Controller P/N 1130440 O 0 0 O 0 0 19 0 0[ 01 0 0 L WT --, :ZONE PLY ADJ SWI 1 2 7 A I0 II B 61$12 K1 n JIA ° J15( F1 ) C.. 1 0 C1 ((• .? C) ; F6-8-1-F-07"1 1 eaejeCDC""c -U)C eUU€aC t� 20+ 24. ( C^ R 3 V I Y2 ' °I 111.12 NO ..NC • FAN DI VAC FAN COO , HEAT EN K2 K3 n ( F2 ) K4 n F5 ) 615P1 K5 n ( 1,5 ) Y1 Y2 WI W2 EC EN FIB CF KG DO NOT CONNECT POWER TO THESE TERMINALS. ATTACH TO EARTH GROUND BELDEN 5441 FE 2 PAIR, 20AWG, STRND, SHLD (BELDEN 6441FE — FOR PLENUM) .TB2 :SET :1 TB2:SET: 1 TB1 :TMP :+ TB1 :TMP. TAPE SHIELD (TYP.) BLK /2- RTU:TB3: +ADJ WHT /2— RTU:TB3: --ADJ BLK /1- RTU:TB3: +ZONE, RED/1 -RTU:TB3:-ZONE 2.15" I P/N 150748 - ZONE TEMPERATURE SENSOR IV /COOL /WARM ADJ INCLUDED W /P /N 150744 --. RTU 1 1 4 P/N 150744 Q3RTU KIT KIT INCLUDES THE FOLLOWING ITEMS: P/N 150440 - .Q3RTU P/N 300199 - 8" DUCT MOUNT TEMP SENSOR P/N 150748 - ZONE COOL /WARM ADJ P/N QTY DESCRIPTION 150744 1 Q3RTU CONTROLLER (RTU1) 150748 1 ZONE TEMP SENSOR W /ADJ (ZTS1) 300199 .1 SPLY AIR. DUCT TEMP SENSOR (STS1) FIELD WIRING LEGEND WIRE COLOR/P1R ## DEVICE CRED /1- RTU :TB3: +SPLY TERMINAL BLOCK POSISITION CABLE PAIR. LEGEND: RED /1 BLK/1 = PAIR 1 WIfT /2 BLK/2 = PAIR 2 INSTALLATION NOTE( #8): .. . MOUNT RTU CONTROLLER IN RTU /HVAC CONTROL PANEL USING 3" TDK SNAP -TRACK PROVIDED. IF IT IS A SPLIT SYSTEM, MOUNT THE RTU 3.2" CONTROLLER IN THE AIR HANDLER UNIT. IF COMMUNICATIONS WITH Q3 CANNOT BE ESTABLISHED, EACH RTU CONTROLLER IS CAPABLE OF MAINTAINING THE TEMPERATURE OF THE HVAC ZONE INDEPENDENTLY. INSTALLATION NOTE( #7): !! INSTALLATION CONTRACTOR IS RESPONSIBLE FOR USING CABLE. /WIRE THAT EITHER MEETS OR EXCEEDS THE WIRE SPECIFIED IN THIS DRAWING. ANY DEVIATIONS FROM THE WIRE SPECIFIED COULD AFFECT THE PROPER OPERATION OF THE SYSTEM. !! . COLEMAN 55308 8 COND 18AWG SLD T —STAT INSTALLATION NOTE( #8): ** CONTACT T-- MOBILE PROJECT MANAGER IF THERE ARE MORE THAN TWO HVAC UNITS TO REQUEST ADDITIONAL RTU CONTROLLERS OR TO REPLACE DAMAGED OR MISSING PARTS. C� LE BRN-RTU:TB2:C) RED- RTU:TB2 :R GRN- ITU:TB2:G YEL- -RTU:TB2:Y1 BLU- RTU :TB2 :Y2 !I1 WHT- RTU:TB2 :W1 1 Q ORN- RTU:TB2 :W2 BELDEN 5441FE 2 PAIR, 20AWG, STRND, SHED (BELDEN 6441FE — FOR PLENUM) INSTALLATION NOTE( #9): TERMINATE SENSOR • CABLE SHIELD(S) TO GROUND AT RTU ONLY. TAPE OFF CABLE SHIELD AT SENSOR. HVAC#1 — VIA ,KE/ nual BLU ORN 24 VAC G FAN Y'1 COMP# 1 Y2 COMP#2 Wr1 /0 HEAT #1 W2 HEAT #2 OIL) REVIEWED FOR -. CODE COMPLIANCE NFPA70 -NEC S = 201U City Of Tukwila BUILDING DIVISION FIELD WIRING 'I. ERMINALS TORQUE ALL FIELD WIRING TERMINALS TO 7 IN -LBS THE LIGHTING AND HVAC CONTROLS CONSIST OF A QUEST ENERGY MANAGEMENT. SYSTEM FURNISHED BY QUEST FOR THE COMPLETE INSTALLATION BY THE ELECTRICAL SUBCONTRACTOR. INFORMATION SHOWN ON ELECTRICAL SHEETS E -400, E -401 AND E -402 ARE TO ILLUSTRATE THE SCOPE OF WORD_. HOWEVER, PRIOR TO ROUGH -IN THE ELECTRICAL SUB - CONTRACTOR SHALL OBTAIN THE LATEST QUEST PLANS FOR REFERENCE AND PROVIDE A COMPLETE INSTALL. COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. to 0 oo on 03 ¢ gin m w m N .J mot w - 7. • • w m ce - Nai co CO 0 N co La gm w i o ,w � V Tui uni tf) QUEST INSTALLATION z 0 aTirco ZI'W W IPIFS le la o Dv Ut;la�o 0 ylb yi t• 01 CO c4 Ln IA. MI co V t o, u 9 . c U z loin 4 m S tnt+- a4 g g RECEIVED AUG 21 2.006 PERMIT CENTER DATE: uS.l4. ©S SHEET: SCALE: DRAWN BY: 1/4" _r-O" vTArr E402 PROJECT No.: TMB©PoI,11 SECTION 16050: GENERAL ELECTRICAL THE DRAWINGS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND DIVISION I APPLY TO WORK UNDER THIS SECTION, 1.00 GENERAL 1.01 DESCRIPTION A. GENERAL: FURNISH ALL LABOR, MATERIALS, APPARATUS, TOOLS, EQUIPMENT, TRANSPORTATION, A. TEMPORARY CONSTRUCTION AND SPECIAL OR OCCASIONAL SERVICES AS REQUIRED TO MAKE A COMPLRETiE WORKING ELECTRICAL INSTALLATION, AS SHOWN ON THE DRAWINGS OR DESCRIBED IN THESE SPECIFICATIONS. B. WORK INCLUDED: I. INSTALL LIGHT FIXTURES. 2. GROUNDING. 5. INSTALLATION OF DUCT SMOKE DETECTORS (IF REQD. BY LL OR JURISDICTION). 4. PROVIDE PANELBOARDS AND OVERCURRENT DEVICES (ONLY AS NOTED ON PLANS). 5. BRANCH CIRCUIT WIRING. 6. EXIT SIGNS AND EMERGENCY LIGHTING SYSTEM. 1. INSTALLATION OF CONVENIENCE OUTLETS. 8. INSTALLATION OF TELEPHONE AND DATA OUTLETS AND RACEWAYS. 41. FURNISHING, SUPPORT AND INSTALLATION OF NEW TRANSFORMER: 10. ROUGH -IN WIRING FOR DISPLAY CASE LIGHTING.. II. DEMOLITION AND REMOVALS. 12. INSTALLATION Q. LIGHTING CONTROLS, AND TIME SWITCHES, 13. CONNECTIONS OF, AND POWER WIRING TO, HVAG EQUIPMENT: 14. CONDUIT FOR DATA, TELEPHONE AND ALARM SYSTEMS. G. RELATED WORK SPECIFIED ELSEWHERE: . IPERFORM THE FOLLOWING WORK, IN AGGORDANGE.WITH APPROPRIATE Si_CTIONS OF THE • SPECIFICATIONS CITED, WHERE AND AS NECESSARY TO FURNISH A COMPLETE, WORKING ELECTRICAL INSTALLATION. A CONCRETE: B. PAINTING: C. DOOR HARDWARE: D. MECHANICAL: 1.02 CODES AND STANDARDS: A. SPECIFIC 1. 2. DIVISION 3 DIVISION q DIVISION II DIVISION 15 COMPLY WITH ALL CODES ENFORCED BY THE STATE AND LOCAL JURISDICTIONS. EQUIPMENT AND MATERIALS SPECIFIED UNDER THIS DIVISION SHALL CONFORM TO THE FOLLOWING STANDARDS WHERE APPLICABLE, A. UL UNDERWRITERS' LABORATORIES. 8. ASTM AMERICAN SOCIETY FOR TESTING MATERIALS. C. GBM CERTIFIED BALLAST MANUFACTURERS. D. ANSI AMERICAN NATIONAL STANDARDS. INSTITUTE. E. NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION 1.03 DRAWINGS: 1.04 A. LAYOUT: GENERAL LAYOUT SHOWN ON THE DRAWINGS SHALL BE FOLLOWED EXCEPT WHERE OTHER WORK MAY CONFLICT WITH THE DRAWINGS. 5. ACCURACY: I. DRAWINGS FOR THE WORK UNDER THIN SECTION ARE DIAGRAMMATIC AND COMPLETE DETAILS I OF THE BUILDING WHICH AFFECT THE ELECTRICAL INSTALLATION ARE NOT SHOWN. COORDINATE WITH DRAWINGS OF ALL OTHER TRADES. 2. CONTRACTOR SHALL VERIFY LIMES, LEVELS AND DIMENSIONS SHOWN ON THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE SETTING OUT OF WORK AND FOR ITS STRICT CONFORMANCE WITH EXISTING CONDITIONS AT THE SITE. SUBSTITUTIONS: SUBSTITUTIONS OF SPECIFIED DEVICES AND EQUIPMENT SHALL NOT BE ALLOWED. 1.05 SUBMTTALS: A. GENERAL: REFER TO THE GENERAL CONDITIONS, SUPPLEMENTARY GENERAL CONDITIONS AND DIVISION I FOR REQUIREMENTS. B. FORMAT: FURNISH SUBMITTAL DATA NEATLY BOUND IN AN 5 -1/2" X II" FOLDER OR BINDER WITH A TABLE OF CONTENTS LISTING IN ORDER OF SPECIFICATION SECTION AND PARAGRAPH NUMBER. G. C. SUBMITTALS SHALL CONSIST OF DETAILED SHOP DRAWINGS, SPECIFICATIONS, CATALOG "GUTS" AND DATA SHEETS CONTAINING PHYSICAL AND DIMENSIONED INFORMATION, PERFORMANCE DATA, ELECTRICAL CHARACTERISTICS, MATERIALS .USED IN FABRICATION, MATERIAL FINISH AND THOSE OPTIONAL ACCESSORIES WHICH ARE INCLUDED AND THOSE WHICH ARE EXCLUDED. D. EACH SUBMITTAL SHALL BE THOROUGHLY REVIEWED BY THE CONTRACTOR. THE COVER LETTER ACCOMPANYING SUBMITTAL LETTER SHALL LIST IN FULL THE ITEMS AND DATA SUBMITTED AND SHALL CONTAIN A STATEMENT ACKNOWLEDGING THAT THE CONTRACTOR HAS PERFORMED A DETAILED REVIEW OF THE SUBMITTAL DOCUMENTS PRIOR TO SUBMISSION. FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL CONSTITUTE GROUNDS FOR RETURN OF DATA FOR RESUBMISSION WITHOUT REVIEW. E. CONTRACTOR AGREES THAT SHOP DRAWING SUBMITTALS PROCESSED 5Y THE ENGINEER ARE NOT CHANGE ORDERS, THAT THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, THAT HE DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH EQUIPMENT AND MATERIAL HE INTENDS TO FURNISH AND INSTALL AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS HE INTENDS TO USE. 1.06 PRODUCT DELIVERY, STORAGE AND HANDLING; EQUIPMENT AND MATERIALS SHALL BE PROPERLY STORED AND ADEQUATELY PROTECTED AND CAREFULLY HANDLED TO PREVENT DAMAGE BEFORE AND DURING INSTALLATION. EQUIPMENT AND MATERIALS SHALL BE HANDLED, STORED, AND PROTECTED IN ACCORDANCE WITH THE MANUFACTURERS'S RECOMMENDATIONS AND AS APPROVED BY THE OWNER'S REPRESENTATIVE. ELECTRICAL CONDUIT SHALL BE STORED TO PROVIDE PROTECTION FROM THE WEATHER AND ACCIDENTAL DAMAGE. PLASTIC CONDUIT SHALL BE STORED ON EVEN SUPPORTS AND IN LOCATIONS NOT SUBJECT TO DIRECT SUN RAYS OR EXCESSIVE HEAT. CABLES SHALL BE.SEALED, STORED AND HANDLED CAREFULLY TO AVOID DAMAGE TO THE OUTER COVERING OR INSULATION AND DAMAGE FROM MOISTURE AND WEATHER. DAMAGED OR DEFECTIVE ITEMS, IN THE OPINION OF THE OWNER'S REPRESENTATIVE, SHALL BE • REPLACED WITH NEW ITEMS AT THE EXPENSE OF THE CONTRACTOR. I.O"1 PERMITS AND FEES: PROVIDE, PROCURE AND PAY FOR ALL PERMITS, LICENSES AND FEES REQUIRED TO CARRY ON AND COMPLETE THE WORK. 2.00 PRODUCTS (NOT APPLICABLE) 5.00 EXECUTION: 3.01 TESTS: A. TESTS SHALL BE GONOUCTED DURING THE CONSTRUCTION PERIOD AND AT COMPLETION TO DETERMINE CONFORMITY WITH APPLICABLE COPES AND WITH THESE SPECIFICATIONS. TESTS SHALL BE PERFORMED IN THE PRESENCE OF THE ARCHITECT AND SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: I. INSULATION RESISTANCE: PERFORM 500 -VOLT D.C. TESTS FOR ONE MINUTE ON ALL FEEDER CONDUCTORS; INCLUDING THE NEUTRAL, AND MAKE A TYPED RECORD OF ALL READINGS TO BE INCLUDED IN THE MAINTENANCE INSTRUCTIONS. REPAIR OR REPLACE CIRCUITS SHOWING LESS THAN 40 MEG OHMS RESISTANCE TO GROUND. MAKE TESTS USING 5IDDLE INSULATION RESISTANCE MEGGER, OR EQUAL. 2. GROUND RESISTANCE: TEST GROUND RESISTANCE PER IEEE STANDARD NO. 51. 5. CIRCUITS CONTINUITY: TEST ALL FEEDER AND BRANCH FOR CONTINUITY. TEST ALL NEUTRALS FOR IMPROPER GROUNDS. . 4. EQUIPMENT OPERATIONS: TEST LIGHTING CIRCUITS FOR CORRECT OPERATION THROUGH THEIR CONTROL DEVICES. TEST ELECTRIC BASEBOARD HEATERS FOR CORRECT OPERATIONS THROUGH THEIR CONTROL RELAYS/THERMOSTATS. 5. LI'H ING CONTROL CIRCUITS: PERFORM OPERATION TESTS FOR ALL LIGHTING CIRCUITS. 6. PRO UGT FAILURE: ANY PRODUCTS WHICH FAIL DURING THE TESTS OR ARE RULED UNSATISFACTORY BY THE OWNER'S REPRESENTATIVE SHALL BE REPLACED, REPAIRED, OR CORRECTED AS PRESCRIBED BY THE OWNER'S REPRESENTATIVE AT THE EXPENSE OF THE CONTRACTOR. TESTS SHALL BE PERFORMED AFTER REPAIRS, REPLACEMENTS OR COR ECTIONS UNTIL SATISFACTORY PERFORMANCE 15 DEMONSTRATED. I "1. PHY S CAL INSPECTION OF ELECTRICAL EQUIPMENT ANC CABLES: INSPECTION SHALL BE MADE OF ALL EQ')IPMENT TO INSURE PROPER ASSEMBLY AND CONSTRUCTION. 5.02 INSTRUCTIONS ANC MANUALS A REFER TO DIVIS ON I B. AT THE TI1�IE OF COMPLETION, AN ADEQUATE PERIOD SHALL 5E ALLOTTED BY' THE CONTRACTOR FOR INSTIUCTIO'I OF BUILDING OPERATING AND MAINTENANCE PERSONNEL IN THE US! OF ALL SYSTEMS. I(4LL. PERSONNEL SHALL BE INSTRUCTED AT ONE TIME, THE CONTRACTOR MAKING ALL NECESSARY ARRANGEMENTS WITH MANUPACTURERS'S REPRESENTATIVES. THE EQUIPMENT MANUFACTURER SHALL PROVIDE PRODUCT LITERATURE AND APPLICATION GUIDES FOR THE USERS' REFERENCE. . C. COSTS, IF ANY, FOR THE ABOVE SERVICE SHALL BE PAID BY THE CONTRACTOR. 5.05 PROJECT trEGORt DOCUMENTS (AS- BUILT) A. PROVIDE I ROJEGT RECORD DRAWINGS AND SPECIFICATIONS AS REQUIRED BY OTHER SECTIONS�OP SPECIFICATIONS AND AS REQUIRED HEREIN. SUCH DRAWINGS SHALL FULLY REPRESENT INSTALLED CONDITIONS INCLUDING ACTUAL LOCATION OF OUTLETS, CORRECT CONDUIT AND WIRE SIZING AS WELL AS ROUTING, REVISED FIXTURE SCHEDULING LISTING THE MANUFACTURER AND PRODUCTS ACTUALLY INSTALLED. . 5. ALL CHANGES TO DRAWINGS SHALL. BE MADE BY QUALIFIED [DRAFTSPERSONS TO MATCH EXISTING LINE WORK ANP LETTERING AS CLOSELY AS POSSIBLE.. 5.04 WORKMANrHIP A. PREPARATION, ANDLING AND INSTALLATION SHALL 5E IN ACCORDANCE WITH MANUi'ACTURER'S WRITTEN INSTRUd TIONS AND TECHNICAL DATA PARTICULAR TO THE PRODUCT SPECIFIED AND /OR APPROVE EXG PT A5 OTHERWISE SPECIFIED. COORDINATE WORK AND COOPERATE WITH OTHER IN FURNIS ING A I9. PLACING THIS WORK. WORK TO APPROVED SHOT' DRAWINGS FOR WORK SY OTHERS A D T FIELD MEASUREMENTS AS NECESSARY TO PROPERLY FIT THE WORK. B. CONFORM TO T E NATIONAL ELECTRICAL CONTRACTOR'S ASSOCIATION STANDARD OF INSTALLA ION F•.R GENERAL INSTALLATION PRACTICE. . 5.05 SGHEDULEI OF W ESTABLISITIED F MAJOR ElUIPM RK: ARRANGE WORK TO CONFORM TO THE SCHEDULE WHICH HAS BEEN R THE PROGRESS OF THE WORK. ADVISE REGARDING SHIPPING SCHEDULE OF T. 3.06 SUPERVISION: CONTRACTOR SHALL PERSONALLY OR THROUGH AN AUTHORIZED AND COMPETENT REPRESEi TATIV CONSTANTLY SUPERVISE THE WORK FROM BEGINNING TO COMPLETION AND, WITHIN REASON, EEP THE SAME WORKMEN AND FOREMAN ON THE .PROJECT THROUGHOUT THE PROJIEGT URA ION. r 3.01 PROTECT! N: K EP CONDUITS, - JUNCTION BOXES, OUTLET BOXES, AND OTHER OPENINGS CLOSED TO PREY NT EN RY OF FOREIGN MATTER. COVER FIXTURES, EQUIPMENT AND APPARATUS AND PROTECT ALAI ST IT PAINT, WATER, CHEMICAL OR MECHANICAL DAMAGE, BEFORE AND DURING CQNSTR CTION PERIOD. RESTORE TO ORIGINAL CONDITION ANY FIXTURE, APPARATUS, OR EQUIPMENT !-AMAGED PRIOR TO FINAL. ACCEPTANCE. PROTECT BRIGHT FINISHED SURFACES AND SIMIfAR I EMS UNTIL IN SERVICE. NO RUST OR DAMAGE WILL SS PERMITTED. 3.05 SPECIAL 10OL ALL SPECIAL TOOLS FOR PROPER OPERATION AND MAINTENANCE OF THE EQUIPMENT ROVIDED UNDER THIS SECTION SHALL BE DELIVERED TO THE OWNER'S REP SENTATIVE. 3.041 CUTTING POND P TCHING A. INSTALL ALL R; QUIRE" SLEEVES, FORMS AND INSETS BEFORE WALLS OR PARTITION AS BUILT. A. • CUTTING AND P TGHING OF WALLS, PARTITIONS, CEILINGS AND FLOOR NECESSARY FOR RECEPTION OF WORK' CAU 15Y FAILURE TO PROVIDE OR PROPERLY LOCATED SLEEVES, FORMS AND INSETS, INGORRE4T LO' ATION OF WORK OR FAILURE TO COOPERATE WITH OTHER TRADES, SHALL BE DONE AT EXPIE;NSE O TRADE RESPONSIBLE. 5. NO CUTTING OF FINISHED OR STRUCTURAL WORK MAY 5E DONE WITHOUT ACCEPTANCE. WHEN NECESSARY TO HAVE FINISHEDD MATERIAL OR STRUCTURAL WORK CUT, FURNISH NECESSARY DRAWING'S TO TRADE WHOSE MATERIALS ARE OUT TO 5E GUT. 3.10 GLEARAN.ES: FROVIDE WORKING CLEARANCE IN FRONT OP, IN BACK OF, AND TO SIDES FOR ALL ELEG RICA_ EQUIPMENT AS REQUIRi P BY NATIONAL ELECTRICAL COPE ARTICLE 110. 1 3.11 DEMOLITION: DEMOLITION AND REMOVAL OF EXISTING ELECTRICAL SERVICES TO THE EXISTING TENANT SPACE TO 5E BY THE CONTRACTOR. 5.12 ACCESS PANEL . A. ELEC. CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS REQUIRED FOR C.ove REQUIRED ACCESS ITO ELECTRICAL DEVICES AND JUNCTION. BOXES. B. ACCESS PANELS SHALL NOT BE ALLOWED IN SALES AREA CEILING OR WALLS. DEVICES AND EQUIPMENT THAT NORMALLY WOULD BE CONGEALED FROM VIEW SHALL BE LOCATED AT NORMALLY ACCESSIBLE AREAS SUCH AS ABOVE CEILING, NEAR HVAG DIFFUSERS OR IN BACK ROOMS N ACCESSIBLE CEILING AREAS. END OF SECTION SECTION 16100; ASIG MATERIALS ANP METHODS THE GENERAL G NDITIONS, SUPPLEMENTARY CONDITIONS, AND DIVISION I APPLY TO WORK UNDER THIS SECTION. 1.00 GENERAL 1.01 DESCRIPTION A. WORK 5 INSTALL. DIVISIOr ECIFIED IN THIS SECTION ENCOMPASSES PRODUCTS, ASSEMBLIES AND BASIC TION 1IETHODS REQUIRED FOR ELECTRICAL PROJECT SYSTEMS SPECIFIED UNDER THIS AND . NCLUDES, BUT IS NOT LIMITED TO: . I. CO DUIT, RACEWAYS, AND FITTINGS. 2. WI E AND GABLES. 5. WIDE CONNECTIONS AND DEVICES. 4. OUTLET 60XES. 5. PURL AND .JUNCTION BOXES. 6. 5W TCHES AND R! GEPTAGLES. 1. DE ICE PLATES. • :5. OVERGURRENT PROTECTIVE DEVICES. 1. TE EPHONE TERMINAL BACKBOARD. 10. PA�IELBOARDS AND ASSOCIATED EQUIPMENT 1.01 SUBMITTAL5 A. SUBMIT •1 CONFORMANCE WITH THE REQUIREMENTS OF SECTION I6O50 THE FOLLOWING ITEMS: TGHES RECEPTACLES ANC, DEVICE PLATES. CONDUCTOR S AND CABLES, I. SW� , 2. OVERCURRENT PROTECTIVE DEVICES. . 5. RAGEWA``5. 4. PANELBOARDS AND TRANSFORMER 5. GAyBLE TRAY . 2.00 PRODUCI TS 2.01 GONDUI AND FITTINGS A. RIGID 5 EL CONDUIT I. G NDUIT, RIGID STEEL: FULL WEIGHT, THREADED, HOT -DIP GALVANIZED, INSIDE ENAMELED, G NFORMING TO ANSI 480.1. 2. THj EEPP EGE COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON. EFCOR 165 SERIES, O. -. /GEDNEY 4 -50 SERIES OR EQUAL. . S. THH ADLESS COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON; WITH INTEGRAL CONDUIT STEP. E>~GOR 1160. 4. THREADLESS CONNECTORS: ELECTROPLATED, CAST MALLEABLE IRON, ON THREADED MALE HU5 PLASTIC INSULATED THROAT RATED 410 DEGREES C MINIMUM. EFCOR 115015 SERIES, O.- . /GEDNEY 51 -050 IT SERIES OR EQUAL.. 5. INSULATED BUSHINGS: THREADED POLY PROPYLENE OR THERMOSETTING PHENOLIC RATED 150 DEGREES G MINIMUM. 6. INSULATED GROUNDING BUSHINGS: THREADED CAST MALLEABLE IRON 5017Y WITH INSULATED THROAT AND .STEEL, "LAY -IN" GROUND LUG WITH COMPRESSION SCREW.. O.Z. /GEDNEY 5L6 SERIES, THOMAS BETTS 5510 SERIES OR EQUAL. 1. INSULATED METALLIC BUSHINGS: THREADED CAST MALLEABLE IRON BODY WITH PLASTIC INSULATED THROAT RATED 105 DEGREES G. O.Z. /GEDNEY TYPE B, THOMAS 4 BETTS 1222 SERIES OR EQUAL: 5. ELECTRICAL METALLIC TUBING (EMT) 1. CONDUIT: SHALL SE FORMED OF COLD ROLLED STRIP STEEL, ELECTRICAL RESISTANCE WELDED I. CONTINUOUSLY ALONG THE LONGITUDINAL SEAM AND HOT -DIP GALVANIZED AFTER FABRICATION. CONDUIT SHALL CONFORM TO ANSI. C. O.3 SPECIFICATIONS AND SHALL MEET U.L. REQUIREMENTS. 2. COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON, GLAND COMPRESSION TYPE, U.L. LISTED RAIN AND CONCRETE TIGHT THROUGH 1 -1/4 INCH. TRADE SIZE, O.Z. /GEDNEY 605OW SERIES, EFGOR 160 SERIES OR EQUAL. SET SCREW TYPE COUPLINGS MAY BE USED IN PRY LOCATIONS, O.Z. /GEDNEY SO50 SERIES OR EQUAL, 5. CONNECTORS; GLAND COMPRESSION TYPE WITH CAST MALLEABLE IRON BODY WITH MALE HUS AND INSULATED PLASTIC. THROAT 150 DEGREES C. TEMPERATURE RATED. O.Z. /GEDNEY 4050 SERIES OR EQUAL: C. FLEXIBLE METALLIC CONDUIT I. CONDUIT: SHALL BE FABRICATED IN CONTINUOUS LENGTHS FROM GALVANIZED STEEL STRIP, SPIRALLY WOUND AND FORMED TO PROVIDE AN INTERLOCKING DESIGN. 6' MAX. LENGTH FLEXIBLE GONDUIT.15 NOT PERMITTED IN WALLS. 2. FITTINGS: CONNECTORS SHALL BE MADE OF THE SCREW CLAMP WITH CAST MALLEABLE IRON BODIES AND THREADED MALE HUBS WITH INSULATED THROATS. S. FLEXIBLE CONDUIT SHALL ONLY BE ALLOWED IN THE LENGTHS AND FOR APPLICATIONS AS ALLOWED BY THE ..JURI5DIGTION.ANC LANDLORD. CONTRACTOR SHALL 8E RESPONSIBLE FOR CORRECTING INSTALLATION THAT IS NOT IN COMPLIANCE WITH THE JURISDICTIONAL /LANDLORD iREQUIREMENTS LIQUID TIGHT FLEXIBLE METALLIC CONDUIT I. CONDUIT: ANACONDA TYPE U.A., COLEMAN TYPE UXTI OR EQUAL. 2. FITTINGS: CONNECTOR BODY AND GLAND NUT SHALL BE OF CADMIUM PLATED CAST MALLEABLE. IRON, WITH INSULATED THROAT, MAX.. 24 ", T * 5 5551 SERIES, O.Z. /GEDNEY 40-5S-IT T SERIES, OR EQUAL. E. MINIMUM ACCEPTABLE CONDUIT SIZE SHALL BE 1/2 INCH. F. MG CABLING (ONLY AS ALLOWED BY LANDLORD AND JURISDICTION) 1. METAL CLAD GABLE SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH UL 1561. THE GABLE 1. SHALL BEAR THE UL LABEL AND MANUFACTURER'S "E" NUMBER ACCEPTABLE SIZES FOR MG GABLE: 12/2 THROUGH 12/41; 10/2 THROUGH 10/ 41 AND SHALL CONTAIN COPPER CONDUCTORS ONLY, NO ALUMINUM ALLOWED 2. 4. 5. 6. MANUFACTURER - AFC OR EQUAL CONDUCTORS: COPPER; SOLID OR 5-TRAMPED . INSULATION: THERMOPLASTIC (THHN) OR EQUIVALENT; VOLTAGE RATING 600V; TEMPERATURE RATING 410°C. ARMOR: ALUMINUM; CORRUGATED OR SMOOTH TUBE "1. NOT USED &. GABLE SHALL BE FIRE RATED, I HOUR MINIMUM OR HIGHER AS REQUIRED BY SPECIFIC INSTALLATION S. AREA, UL LISTED, RATED FOR USE IN CABLE TRAY, AND FOR USE IN ENVIRONMENTAL AIR PLENUMS q. CONNECTORS: FURNISH ONLY UL LISTED MC CONNECTORS MANUFACTURED FOR MC GABLE. 10. CONNECTORS SHALL BE STEEL; DIE CAST NOT ALLOWED. MG CABLING SUPPORTS: CADDY, OR APPROVED EQUAL. ALL SUPPORTS SHALL 5E U.L. LISTED FOR THE APPLICATION, AND SHALL COMPLY WITH THE NEC. TIE -WRAPS AND STAPLES+ ARE NOT ACCEPTABLE. UTILIZE THE FOLLOWING: . I. SNAP -IN SUPPORTS TO FRAMING STUD, CADDY #MAG2. . 2. STRAP TO FRAMING STUD GADDY #FX02O 5. DROP -WIRE SUPPORTS, GADDY #PGEI. 4. GABLE SNAP CLIP FOR ATTACHMENT TO STRUCTURE CADDY #SC. 5. GABLE SUPPORT FOR ATTACHMENT TO FRAMING STUD, CADDY #4.16 6. SUPPORT AND ANTI - RATTLE CLIP FOR MG. THROUGH STUDS; GADDY # "1$I. 11,• MC CABLING SHALL ONLY BE ALLOWED FOR APPLICATIONS AS ALLOWED BY THE JURISDICTION AND THE LANDLORD. PRIOR TO INSTALLATION, CONTRACTOR SHALL CONFIRM WITH BOTH AGENCIES, THAT MC 15 PERMITTED. FOR INSTALLATIONS THAT HAVE NOT BEEN APPROVED BY BOTH AGENCIES, THE CONTRACTOR SHALL 5E RESPONSIBLE FOR THE REMOVAL OF THE MC AND REPLACEMENT WITH EMT, AT THE EXPENSE OF THE CONTRACTOR. 12. MG CABLING SHALL NOT 5E ALLOWED TO RUN INTO THE PANELBOARDS. TRANSITION TO EMT BY MEANS OF A WIREWAY ABOVE PANELBOARDS, AND RUN BRANCH CIRCUITS IN EMT FROM WIRREWAY TO PANEL OARDS NO EXCEPTIONS 13. CONTRACTOR'S BID SHALL REFLECT COSTS .FOR UTILIZING MG CABLING AND /OR EMT INSTALLATION AS PERMITTED BY THE JURISDICTION AND LANDLORD. 14. MC GABLE SHALL NOT BE PERMITTED IN AREAS OPEN TO PUBLIC VIEW. 2.02 WIRE AND GABLE A. GENERAL I. ACCEPTABLE MANUFACTURERS: GENERAL ELECTRIC CO., ROME GABLE, S DUTHWIRE , TRIANGLE, I. CONDUCTOR MATERIAL: ALL WIRE AND GABLE SHALL BE INSULATED COPPER CONDUCTORS FOR ALL PWC INC„ OR EQUAL. 2. WIRE SIZES. ALUMINUM WIRE AND CAi5LE SHALL NOT 5E USED. 5. INSULATION: INSULATION SHALL BE THWN -THHN FOR WIRE SIZES THROUGH SIZE I/O MG. FOR LARGER WIRE SIZES INSULATION SHALL BE THAN, XHHW, THW OR AS REQUIRED TO SUIT APPLICATION. 4. . FIXTURE WIRE; TYPE AF. 5. MINIMUM CONDUCTOR SIZE: POWER AND LIGHTING BRANCH CIRCUITS: SIGNAL AND CONTROL CIRCUITS UNDER 100 VOLTS: ANY 120V./ 20A. CIRCUITS OVER 15 L.F. MUST 5E: COLOR GORE. COLOR CODE ALL CONDUCTORS IN PHASE A PHASE 5 PHASE G NEUTRAL #12 AWG #14 AWG: #IQ A. ACCORD WITH 6 . O L 8 COD - -jA �� 4LO N SA G. SWITCHES: TWENTY AMPERE, 120 -211 VOLTS, PAST MAKE -SLOW 5REAK, QUIET TYPE SWITCH WITH SILVER CADMIUM ALLOY CONTACTS, BINDING HEAD TERMINAL SCREWS, SIDE WIRED ONLY. ALL .SWITCHES SHALL BE GREY IN COLOR WITH BRUSHED STAINLESS STEEL COVER PLATE. . 1. SINGLE POLE, SINGLE THROW, LEVITON #1221 OR EQUAL. 2. THREE -WAY, LEVITON #1225 OR EQUAL. 2.05 DEVICE PLATES A. PLATES: WHITE. 5. SURFACE MOUNTED DEVICES, INDOOR: GALVANIZED METAL TO FIT BOX. C. OUTDOOR, WEATHERPROOF: PIE CAST ALUMINUM CONSTRUCTION, CORROSION RESISTANT, HEAVY DUTY, HINGED COVER FLAP, AND GASKET, LEVITON #6116, HORIZONTAL MOUNTING. 2.06 D15 . )NNEGT SWITCHES A. SWITCH INTERIOR: DEAD -FRONT .CONSTRUCTION WITH HINGED ARC SUPPRESSOR AND SWITCH BLADES WHICH ARE FULLY VISIBLE IN THE "OFF "" POSITION ANP WITH DOOR OPEN. 5. SWITCH MECHANISM: QUICK -MAKE AND QUICK -BREAK OPERATING HANDLE AND MECHANISM WITH DUAL COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR IN THE "ON" POSITION OR CLOSING THE SWITCH MECHANISM WHILE THE POOR 15 OPEN. . G. RATINGS: SWITCHES SHALL BE HORSEPOWER RATED FOR THE OPERATING VOLTAGE AND WITH FUSED OR NON -FUSED ARRANGEMENTS AS SHOWN ON THE DRAWINGS. . D. ENCLOSURES: NEMA I, GODS GAUGE SHEET STEEL WITH HINGED COVER, OR . . NEMA SR AS SHOWN ON DRAWINGS, AND AS REQUIRED BY APPLICATION. 2.01 TRANSFORMERS (ONLY AS SHOWN ON PLANS) . A. TRANSFORMERS SHALL TEE INDOOR TYPE, SELF COOLED, 4S0V, THREE- PHASE, DUAL WINDING, FULLY ENCLOSED; VENTILATED, GENERAL PURPOSE DRY TYPE, 4S0 VOLT PRIMARY, 120/20P VOLT SECONDARY, 60 HERTZ, EQUIPPED WITH TWO 2 I/2% PULL CAPACITY TAPS ABOVE AND BELOW RATED VOLTAGE AND SHALL BE OF THE KVA RATING SHOWN ON THE DRAWINGS. TRANSFORMERS SHALL HAVE COPPER OR ALUMINUM WINDINGS GLASS 'H' INSULATION GROUP, WITH TEMPERATURE RISE, WHEN OPERATED CONTINUOUSLY AT FULL LOAD AND RATED FREQUENCY, NOT EXCEEDING 150 DEGREE C.' RISE OVER 40 DEGREE C. AMBIENT, UNLESS MENTIONED OTHERWISE ON THE ONE LINE DIAGRAM. . C. TRANSFORMER SHALL HAVE A MINIMUM OF 10% OVERLOAD CAPACITY AT RATED VOLTAGE AND SHALL HAVE A 10 KV BIL RATING. D. SOUND LEVEL AT ANY LOAD SHALL NOT EXCEED 45 P5 WHEN TESTED IN A ROOM WITH AMBIENT SOUND LEVEL NOT EXCEEDING 24 P5. EXCESSIVELY NOISY TRANSFORMERS SHALL BE REPLACED WITH NEW AT THE EXPENSE OF THE CONTRACTOR. E. TRANSFORMER IMPEDANCE SHALL NOT BE LESS THAN 4% NOR GREATER THAN 5%. TRANSFORMERS SHALL CONFORM TO NEMA TRI- 1114, NEC, 45O-2I AND ALL, APPLICABLE STATE AND LOCAL' GO. DES. F. TRANSFORMER SHALL NOT CONTAIN ANY PUB'S (POLYCHLORINATED BIPHENYLS). G. TRANSFORMER SIZE SHALL PIT SPACE ALLOCATED PER DRAWINGS. H. MANUFACTURER SHALL 55 GE, SIEMENS, CUTLER HAMMER, OR SQUARE D I. ELECTRICAL CONTRACTOR SHALL PROVIDE TRANSFORMER AS INDICATED ON THE PLANS 2.08 PANELBOARDS A. RATINGS: SEE PANEL SCHEDULES. 5. FINISH: ALL PAINTED STEEL WORK SHALL BE TREATED WITH A PRIMER COAT AND FINISH GOAT OF THE MANUFACTURER'S STANDARD GRAY DOLOR OR ANSI 61. C. ELECTRICAL CONTRACTOR SHALL' PROVIDE ALL PANELBOARDS AS INDICATED ON THE PLANS. D. PANELBOARPS SHALL BE KEYED ALIKE, AND ARRANGED TO FIT IN THE SPACE INDICATED ON THE PLANS E. BUSSING I. BUSSING SHALL 5! RECTANGULAR CROSS SECTION FULL LENGTH TIN PLATTED 2. EACH PANELBOARD SHALL BE EQUIPPED WITH A GROUND BUS SECURED TO THE INTERIOR OF THE ENCLOSURE. THE BUS SHALL SE EQUAL TO THE PANELBOARD NEUTRAL. BUS AND SHALL HAVE A SEPARATE LUG FOR EACH GROUND GONPUGTOR. NOT MORE THAN ONE CONDUCTOR SHALL BE INSTALLED PER LUG. . 5. EACH ISOLATED GROUND PANELSOARD SHALL BE EQUIPPED WITH A ISOLATED GROUND BUS SECURED TO THE INTERIOR OF .PANELBOARD WITH A SEPARATE ISOLATED GROUND WIRE .(SIZED PER THE NEC) RUN SACK TO THE GROUNDING ELECTRODE , F. MANUFACTURER SHALL BE GE, SIEMENS, CUTLER HAMMER, OR SQUARE D G. PRIOR TO ORDERING, THE ELECTRICAL CONTRACTOR SHALL CONFIRM WITH THE SERVING UTILITY AND THE LANDLORD, THE AVAILABLE FAULT CURRENT LEVEL AT THE TENANT DISCONNECT. TENANT PANELBOARDS SHALL BE. ORDERED WITH AN AIC RATING GREATER THAN THE AVAILABLE FAULT CURRENT LEVEL. IF CONTRACTOR POES NOT CONFIRM FAULT CURRENT LEVEL, EQUIPMENT FULLY RATED AT 65K Al G MINIMUM SHALL BE REQUIRED. 2.041 PROTECTIVE DEVICES r 120/208V 2'1'f/4 ^U 80V 4. �.� BLACK RED BLUE WHITE 2,05 OUTLET 50XES AND COVERS BROWN ORANGE YELLOW GRAY A, . STANDARD OUTLET BOXES: GALVANIZED, ONE - PIECE, PRAWN STEEL, KNOCK -OUT TYPE OF. A. SIZE AND CONFIGURATION BEST SUITED TO THE APPLICATION INDICATED ON THE PLANS. MINIMUM BOX SIZE, .4 INCH SQUARE 5Y 1 -1/2 INCH DEEP. ACCEPTABLE MANUFACTURERS: STEEL CITY, APPLETON, ROCO, PYLE NATIONAL, KILLARK AND HOPE. B. SWITCH BOXES: TWO INCH BY 3 -INCH LONG, GALVANIZED STEEL SWITCH BOXES SHALL BE USED ONLY FOR THE INSTALLATION OF SINGLE SWITCHES, INSTALL MULTIPLE SWITCHES IN STANDARD GANG BOXES WITH RAISED DEVICE COVERS SUITABLE FOR THE APPLICATION INDICATED. G. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY, BUT NOT SMALLER THAN 4- II /16" SPARE X 2 -I/$" DEEP WITH SINGLE -GANG RING AND SIERRA #S -754N SPLIT PLATE BUSHING. 2.04 SWITCHES AND RECEPTACLES A. GENERAL: COLOR OF DEVICES SHALL BE WHITE WITH WHITE COVER PLATE. FOR I.G. RECEPTACLES, USE ORANGE DEVICE WITH WHITE COVERPLATE, ENGRAVED WITH "ISOL. I. ALL GENERAL PURPOSE 20 AMPERE, 125 -250 VOLT RECEPTACLES AND 120 -211 VOLT SWITCHES SHALL CONFORM TO NEMA AP I AND APPLICABLE U.L. TESTS. 6. RECEPTACLES: I. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE: NEMA, TYPE 5 -20R LEVITON #6541$ -HG OR EQUAL. . 2. DUPLEX RECEPTACLES: NEMA TYPE 5 -20R, HEAVY DUTY SPECIFICATION GRADE, SIDE WIRED ONLY, LEVITON 5245 OR EQUAL, 5. GASH REGISTER RECEPTACLES: NEMA TYPE 5 -20R, HEAVY DUTY SPECIFICATION GRADE, SIDE WIRED ONLY, HUt 5ELL #10 -5562, PROVIDED WITH GREEN INSULATED GROUND WIRE. 2.10 A. CIRCUIT BREAKERS: MOLDED CASE, BOLT -ON, THERMAL MAGNETIC TYPE, 40 DEGREES G. AMBIENT TEMPERATURE COMPENSATED, FIXED MOUNTING, WITH QUICK -MAKE AND QUICK -BREAK SWITCHING MECHANISM MECHANICALLY TRIP -FREE FROM THE OPERATING HANDLE B. RATINGS: REFER TO DRAWINGS AND PANEL SCHEDULES FOR TRIM FRAME AND POLES REQUIRED. EQUIPMENT SHALL BE FULLY RATED BASED ON AVAILABLE FAULT CURRENT LEVEL. G. MANUAL MOTOR STARTERS: FRACTIONAL M.P. I PHASE MOTORS SHALL BE PROTECTED BY THERMAL O.L. RELAY INTEGRAL WITH THE DISCONNECT: • "MOTOR- MINDER ", OR EQUAL. ELECTRICAL SUPPORTING DEVICES A. CONDUIT STRAPS: HOT -DIP GALVANIZED, CAST MALLEABLE IRON, ONE HOLE TYPE STRAP WITH CAST CLAMP -BACKS AND SPACERS AS REQUIRED. O.Z,/GEDNEY #I4 -504 STRAP AND #1416 SPACER, REFGOR #251 STRAP AND #15I SPACER, OR EQUAL. 5, CONSTRUCTION CHANNEL: H/2 INCH BY I -1/2 INCH 12 GAUGE GALVANIZED STEEL CHANNEL WITH 11/52 INCH DIAMETER BOLT HOLES, 1 -1/2 INCHES ON CENTER, IN BASE OF THE CHANNEL. KINDORF 4105 SERIES, UNISTRUT P- 1000-HS, OR EQUAL. FASTENERS (GENERAL): WOOD SCREWS FOR FASTENING TO WOOD. MACHINE SCREWS FOR FASTENING TO STEEL. TOGGLE BOLTS FOR FASTENING TO HOLLOW CONCRETE BLOCK, GYPSUM SOAR" OR PLASTER WALL. EXPANSION ANCHORS FOR ATTACHMENTS TO PRE- POURED CONCRETE. 2.11 IDENTIFYING DEVICES A. PANELBOARD DIRECTORIES: SHALL SE TYPEWRITTEN, ARRANGED IN NUMERICAL ORDER AND SHALL SHOW THE NUMBER OF THE CIRCUIT IS INDICATED. THE ROOM NUMBERS USED SHALL BE VERIFIED WITH THE OWNER AND SHALL NOT NECESSARILY 55 THOSE USED IN THE DRAWINGS. MOUNT DIRECTORIES IN A 6" X .5 METAL FRAME UNDER PLEXIGLA55 INSIPE'EACH PANELBOARD. 5. WIRE 8 TERMINAL MARKERS: SELF- ADHERING, PRE - PRINTED VINYL WITH SELF - LAMINATING WRAP GROUND STRIP BRADY 514t1 SERIES, THOMAS BETTS WSI SERIES, OR EQUAL. . COPYRIGHT NOTICE; . These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec. 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design. Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability. 0 O co CO < uti m • (.4� W u. 1- • ILA om Q _cm mm o vu I1 t 0 i' tN r F-• E-4 1L co rr ,42 2 al CO CU c CI) tai /y am �/ rwr VA2 0 N 9 ccE wg uJ c9a4.4 z- ae ILI 5 zzmNiV, ®Oat z 0 m N r• Ch 00 r ce) 0 :e n 1 w- o � -I- eC av N -(0 00 0 e O r4 zfao tm RECEIVED AUG 2 1 2000 'ERMIT CENTER DATE: SCALE: DRAWN BY: PROJECT No.: 08.14.0' SHEET: 1/4" =1' -0" STAFF E500 TMS08OI a 2.12 PLYWOOD BACKBOARDS A. WHERE INDICATED FOR TELEPHONE OR COMMUNICATION SYSTEM TERMINALS, OR FOR MOTOR CONTROL OR OTHER EQUIPMENT ASSEMBLES, PROVIDE BACKBOARDS OF SIZE INDICATED. I, USE DOUGLAS FIR PLYWOOD, EXTERIOR GRADE WITH "B ". FACE, PRIME AND FINISHED PAINTED. . 2. UNLE55 OTHERWISE INDICATED, PROVIDE 5/4 INCH THICK PLYWOOD. 5. ALL PLYWOOD SHALL BE FIRE RESISTANT. 2.15 GROUNDING A. ENCLOSURES OF EQUIPMENT, RACEWAYS, AND FIXTURES SHALL SE PERMANENTLY AND EFFECTIVELY GROUNDED, PROVIDE CODE - SIZED, (UNLESS OTHERWISE INDICATED) COPPER, INSULATED GREEN EQUIPMENT GROUND WITH ALL BRANCH AND FEEDER CIRCUIT RUNS, EQUIPMENT GROUND SHALL ORIGINATE AT PANELBOARD GROUND BUS AND SHALL BE BONDED TO ALL SWITCH AND RECEPTACLE >3OXES AND ELECTRICAL EQUIPMENT ENCLOSURES, E3. BUILDING SERVICES SHALL BE GROUNDED TO BUILDING STEEL AND TO GOLD METALLIC WATER PIPING. C. ISOLATED GROUND CONDUCTORS SHALL TERMINATE ON ISOLATED GROUND BUS AND RECEPTACLE .ISOLATED GROUND LUG$ ONLY. 2.14 LIGHTING CONTROL SYSTEM A. INSTALL A COMPLETE AND OPERATING LIGHTING CONTROL SYSTEM WITH ALL NECESSARY ACCESSORIES, RELAYS, WIRING, CONTACTORS, PHOTOELECTRIC DEVICE, AND PROGRAMMING. . PART 5 EXECUTION 3.01. CONDUIT AND RACEWAY APPLICATIONS. A. RIGID STEEL CONDUIT: FOR ALL EXPOSED AND U/6 CONDUIT EXPOSED TO MEGHANIGAL DAMAGE, MINIMUM SIZE IS 3/4 ". O. ELECTRICAL METALLIC TUBING (EMT): INTERIOR POWER AND LIGHTING BRANCH CIRCUITS WHERE RUN CONGEALED ABOVE SUSPENDED CEILING, IN STUD WALLS, FURRED SPACES, AND WHERE NOT EXPOSED TO MEGHANIGAL DAMAGE, OR ABOVE 6' FROM FLOOR, FLEXIBLE METALLIC CONDUIT: IN DRY LOCATIONS CONNECTION TO TRANSFORMERS, C, (6' MAX.), VIBRATING EQUIPMENT (24" MAX.), AND TO RECESSED LIGHTING FIXTURES, D. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT: IN DAMP AND WET LOCATIONS FOR CONNECTION TO ALL PUMP MOTORS, SOLENOID VALVES, HVAG EQUIPMENT AND SIMILAR DEVICES SHALL BE MADE USING LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT. PROVIDE SEPARATE GROUND. WIRE INDEPENDENT OF CONDUIT, RUN INSIDE CONDUIT AND BONDED AT BOTH ENDS TO ENCLOSURES. MAXIMUM LENGTH OF 24 INCHES, 3.02 . CONDUIT INSTALLATION A. GENERAL L CONDUIT SYSTEM SHALL SE GONGEEALED.UNLESE EEXPO$ED WORK IS CLEARLY CALLED FOR ON DRAWINGS. 2. CONDUITS SHALL BE TIGHTLY COVERED AND WELL PROTECTED DURING CONSTRUCTION USING .METALLIC BUSHINGS AND BUSHING "PENNIES" TO SEAL OPEN ENDS. 5. IN ALL EMPTY CONDUITS OR DUCTS, INSTALL A 200 -POUND TENSILE STRENGTH POLYETHYLENE PULLING ROPE. 4. CONDUIT SYSTEMS SHALL BE ELECTRICALLY CONTINUOUS THROUGHOUT. INSTALL GODS SIZE, INSULATED, COPPER, GREEN GROUNDING CONDUCTOR IN ALL CONDUIT RUNS PULLED WITH PHASE B. LAYOUT I. LOCATIONS OF CONDUIT RUNS SHALL BE PLANNED IN ADVANCE OF THE INSTALLATION AND COORDINATED WITH THE DUCTWORK, PLUMBING, CEILING AND WALL CONSTRUCTION IN THE SAME AREAS AND SHALL NOT UNNECESSARILY CROSS OTHER CONDUITS OR PIPE:, NOR PREVENT REMOVAL OF CEILING OR TILES OR PANELS, NOR BLOCK ACCESS TO MECHANICAL OR ELECTRICAL EQUIPMENT. 2. WHERE PRACTICAL, INSTALL CONDUITS IN GROUPS, IN PARALLEL, FOR VERTICAL AND HORIZONTAL RUNS AND AT ELEVATIONS THAT AVOID UNNECESSARY OFFSETS, EXPOSED CONDUIT SHALL BE RUN PARALLEL OR AT RIGHT ANGLES TO THE CENTERLINES OF S. COLUMNS AND BEAMS. CONDUITS SHALL NOT BE PLACED CLOSER THAN 12 INCHES+ FROM A PARALLEL HOT WATER OR 4. STEAM LINE OR 3 INCHES FROM SUCH LINES GROSSING PERPENDICULAR TO THE RUNS. C. SUPPORTS . I. ALL RACEWAY SYSTEMS SHALL BE SECURED TO THE BUILDING STRUCTURES USING SPECIFIED FASTENERS, CLAMPS AND HANGERS SPACED ACCORDING TO CODE REQUIREMENTS. SUPPORT SINGLE RUNS OF CONDUIT USING ONE HOLE PIPE STRAPS, WHERE RUN HORZONTALLY 2. ON WALLS IN DAMP OR WET LOCATION, INSTALL "CLAMP - BACKS" TO SPACE CONDUIT OFF THE SURFACE. MULTIPLE CONDUIT RUNS SHALL BE SUPPORTED USING "TRAPEZE" HANGERS FABRICATED S. FROM SPECIFIED CONSTRUCTION CHANNEL, MOUNTED TO 3/6 INCH DIAMETER, THREADED STEEL RODS SECURED TO BUILDING STRUCTURES., FASTEN CONDUIT TO CONSTRUCTION CHANNEL WITH STANDARD ONE HOLE PIPE CLAMPS OR THE EQUIVALENT. D. TERMINATION AND JOINTS I. RACEWAYS SHALL BE JOINED USING SPECIFIED COUPLING OR TRANSITION COUPLINGS WHERE DISSIMILAR RACEWAY SYSTEMS ARE JOINED. 2.. CONDUITS SHALL BE SECURELY FASTENED TO CABINETS, BOXES AND GUTTERS USING TWO LOGKNUTS AND AN INSULATING BUSHING OR SPECIFIED INSULATED CONNECTORS. INSTALL GROUNDING BUSHINGS OR BONDING JUMPERS ON ALL CONDUITS TERMINATING AT CONCENTRIC KNOCKOUTS. 3. CONDUIT TERMINATIONS EXPOSED AT WEATHERPROOF ENCLOSURES AND CAST OUTLET BOXES SHALL BE MADE: WATERTIGHT USING SPECIFIED CONNECTORS AND HUBS. 4, INSTALL EXPANSION COUPLINGS WHERE ANY CONDUIT CROSSES A BUILDING SEPARATION OR EXPANSION JOINT. E. PENETRATIONS I. ALL. FLOOR PENETRATIONS SHALL BE SEALED WATER- TIGHT. MAINTAIN FIRE RATING AS REQUIRED, 2. FIRE --SAFE ALL RATED WALL PENETRATIONS USING 5M LISTED FIRE- SAFING SEALANTS AND ASSEMBLIES. 3.05 GABLE: AND WIRE: INSTALLATION A. GENERAL I. CONDUCTORS SHALL NOT BE INSTALLED IN CONDUIT UNTIL ALL WORK OF ANY NATURE THAT MAY CAUSE DAMAGE IE COMPLETED. CARE SHALL BE TAKEN IN PULLING CONDUCTORS THAT INSULATION. IS NOT DAMAGED, U.L. APPROVED NON - PETROLEUM BASE AND INSULATING TYPE PULLING COMPOUND SHALL SEE USED AS NEEDED. 2. ALL GABLES SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER'S REQUIREEMENTE AND WARRANTY. SPLICING AND TERMINATING I. ALL ASPECTS OF SPLICING AND TERMINATING SHALL BE IN ACCORDANCE WITH GABLE MANUFACTURER'S PUBLISHED PROCEEDURES, 2. MAKE UP ALL SPLICES IN OUTLET BOXES WITH CONNECTORS AS SPECIFIED HEREIN WITH SEPARATE: TAILS OF CORRECT COLOR TO ESE MADE UP TO SPLICE. PROVIDE AT LEAST SIX (6) INCHES OF TAILS PACKED IN BOX AFTER SPLICE IS MADE: UP. 3. ALL WIRE AND GABLE IN PANELS, TERMINAL GAiSINETS AND EQUIPMENT ENCLOSURE:$ SHALL BE BUNDLED AND CLAMPED. C. MC GABLE INSTALLATION . I. INSTALL CABLE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN, STRICT AG ORDANCE WITH NFPA 10, ARTICLE 3$4 2. USE SOLID C NDUGTOR FOR BRANCH CIRCUITS 12 AWG AND SMALLER - 3. BEND GABLE ER NEC, ARTICLE 354 4, GROUNDING: ALL CABLE SHALL CONTAIN A GREEN WIRE GROUND. THE JACKET SHAL_ NOT SERVE AS THE ONLY GROUNDING MEANS 5. SP: I. US I. ENSIONGABLE SHA L BE STRAPPED TIGHT TO UNDERSIDE OF DECKING WHERE PRACTICAL. 2. 2. GABLE SH LL HAVE INDEPENDENT SUSPENSION AND SHALL NOT BE TIED TO CEILING 5, GRID EUSPEN ION SYSTEM, PLUMBING PIPING, OR SPRINKLER PIPING. 4. 3, CABLE SHILL BE GROUPED SEPARATELY FROM LOW VOLTAGE GABLE SYSTEMS. 5, 4, SUPPORT GBLE EVERY 6 FEET, MAXIMUM. 6, 5, CA BLE SHA L .BE STRAPPED EVERY 6'-0', AT EACH TURN AND WITHIN 12 INCHES OF ALL JUNCTION BOXES USING GABLE STRAPS, NOT TIES. 1. 6. BUNDLING: INETA_L NO MORE THAN .4 GABLES TOGETHER IN A SINGLE BUNDLE 6. ROUTING: I. SENDING RADIUS SHALL BE APPROXIMATELY 12 TIMES THE EXTERNAL DIAMETER OF THE METAL SHEATH. 2. ROUTING OF THE CABLE SHALL FOLLOW THE ORTHOGONAL GRID OF THE BUILDING STRU TURN- ELEMENTS OF THE I;SUILDING, SUCH AS BEAMS AND PURLINS. . 5.04 A. 5. CABLE IN CEEIINGS SHALL RUN AS TIGHT TO STRUCTURE A$ POSSIBLE, AND IN NO CASE (IN TH THE EXCEPTION OF DROPS) LESS THAN 12 INCHES ABOVE ACCESSIBLE CEILINGS. 4. MC GABLE SHALL NOT BE USED IN FINAL HOMERUN CONNECTION TO THE BRANCH CIRGLIT PANEL 5. ISOLATED GROUND CIRCUITS AND NORMAL GROUND CIRCUITS SHALL BE RUN IN SEPARATE ¶ABLEE. 6. GABLE SHALL E INSTALLED USING BUSHINGS OR BUSHED rITTINGS, INSTALLATION OP GENERAL OXES AND WIRING SERVICES I. ALL OUTLETS SH LL F NISH FLUSH WITH WALL FINISHES AND CEILING, EXCEPT WHERE EXPOSED WORK IS CALLED FOR. THERE SHALL BE NO GAP BETWEEN BOX AND WALL OR CEILING MATERIAL. ANY OPENING BETWEEN BOX AND WALL OR CEILING SHALL BE CAULKED AIRTIGHT. INSTALL RAISED DEVICE COVERS ON ALL OUTLET BOXES A$ WITH SURFACE, rOVERS SHALL BE OF A DEPTH TO SUIT THE 5. LEAVE NO UNUSED OPENINGS IN ANY BOX. INSTALL CLOSE-UP SEAL OPENINGSI, REQUIRED TO FINISH FLUSH WALL OR CEILING FINISH, PLUGS AE REQUIRED TO 4. EXPOSED OUTLET BOXES AND BOXES. IN DAMP AND WET LOCATIONS SHALL BE CAST METAL WITH GASKETED CAST METAL COVER PLATES. B. BOXES LAYOUT I. OUTLET BOXES SHALL BE INSTALLED AT THE LOCATIONS AND ELEVATIONS SHOWN ON THE DRAWINGS 9R SP7j.C.IFIED HEREIN. MAKE ADJUSTMENTS TO LOCATIONS AS REQUIRED BY 5 RIJCTURAL GONDITIONE AND TO SUIT COORDINATION REQUIREMENTS OF OTHER TRADES. f 2. OUTLET BOXES 1111 STUD WALL AND PARTITIONS SHALL NOT BE. MOUNTED BACK- TO- -5AGK NOR SHALL THRQUGH -WALL BOXES BE PERMITTED.. 5. WHERE INSTALL I ION IS WITHIN OR BEHIND GAS) =WORK, COORDINATE EXACT LOCATION WITH CASEWORK CONTRACTOR PRIOR TO ROUGH -IN TO ENSURE ACCESSIBILITY. C. SUPPORTS I. BOXES INSTALLED IN STUD WALLS SHALL BE EQUIPPED WITH BRACKETS DESIGNED FOR ATTACHING DIRECTLY TO THE STUDS OR SHALL BE MOUNTED ON HEAVY GAUGE GALVANIZED STEEL BOX SUPPORTS. 2. FIXTURE OUTLET AND PLASTER c' ATTACHED TO M IOXES INSTALLED IN SUSPENDED CEILINGS OF GYPSUM BOARD OR LATH NSTRUGTION SHALL BE MOUNTED TO 16 GAUGE METAL CHANNEL BARS IN CE: LING RUNNERS, 3: FIXTURE OUTLETXES INSTALLED IN SUSPENDED CEILINGS SYSTEMS SUPPORTING ACOUSTICAL TILES OR PANELS SHALL Be SUPPORTED DIRECTLY FROM THE STRUCTURES ABOVE . WHEREVER PENDANT - MOUNTED FIXTURES ARE INSTALLED FROM THE BOX: D. MOUNTING HEIGHTS: UN TO CENTER LINE OF WITH HANDICAPPED A DEVICE: ESS NOTED OTHERWISE HEIGHTS ARE FROM FINISHED FLOOR >EVIC1= BOX SHALL BE AS FOLLOWS, AND IN AGCORDANGEE GESS BILITY REQUIREMENTS OF STATE: CODE. HEIGHT(INCHES) . IS CONVENIENCE RECEPTACLE CONVENIENCE: REC PTAGLES ABOVE COUNTERS UNLESS OTHERWISE NOTED SWITCHES, LIGHT TELEPHONE OUTLET 44 46 la 3,05 TRANSFORMER INSTALLATiON A. TRANSFORMER SHALL E FLOOR MOUNTED A5 SHOWN ON THE DRAWINGS. FURNISH AND INSTALL ALL MOU TING 4ARDWARE TO SAFELY CARRY THE WEIGHT OF THE TRANSFORMER. MAINT IIN ADEQUATE SPACING FOR VENTILATION AS RECOMMENDED BY THE MANUFACTURER AND REQUIRED BY CODE. PROVIDE KORFUND TYPE VIBRATION ISOLATION PADS FOR EACH TRANSFORMER. B. CONNECTIONS TO TRANSFORMER SHALL BE MADE WITH FLEXIBLE METALLIC CONDUIT. INSTALL C. GROUND CONDUCTORS IN EACH CONDUIT AND PROVIDE GROUNDING BUSHINGS AS REQUIRED. PROVIDE HEAT INSULATING BARRIER BELOW TRANSFORMER WHERE INSTALLED ON COMBUSTIBLE D. SURFACE, END OF SECTION ELECTRICAL SPECIFICATIONS (CONTINUED) SECTION 16510: LIGHTING FIXTURES PART I GENERAL . 1,01 DESCRIPTION A. WORK .INCLUDED I, INSTALLATION AND GONNEGTION OF ALL FIXTURES, LAMPS, BALLASTS, LIGHTING CONTROL DEVICES, RELAYS, RELATED COMPONENTS AND ACCESSORY WIRING AS SHOWN ON THE PLANS, FIXTURE SCHEDULE OR A5 SPECIFIED 2. PROVIDE ALL. LIGHT FIXTURES AND LAMPS, EXCEPT THOSE NOTED As FURNISHED BY OWNER. FINAL AIMING AND ADJUSTMENT OF RECESSED ADJUSTABLE FIXTURES AND TRACK MOUNTED 3. FIXTURES SHALL E BY THE ELECTRICAL CONTRACTOR, AS DIRECTED BY THE OWNER'S REFIRE ENTATI VE. B. RELATED WORK SPEGI IED ELSEWHERE: REFER TO SECTION 16050 FOR REQUIREMENTS APPLIGr5LE -0 THIS SECTION. . 1.02 COORDINATION: REFS I TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF LIGHTING FIXTURES. . 1.03 SUBMITTALS: SUBMIT IN CONFORMANCE WITH THE REQUIREMENTS OF SECTION 16050: TIME SWITCHES, CONTROL DEVICES, RELAYS AND CABINETS AND WIRING DIAGRAMS. 2.00 EXECUTION 2.01 INSTALLATION A. CONTRACTOR SHALL BE RESPONSIBLE FOR HANDLING AND STORAGE. FIXTURES SHALL BE INSTALLED A. PLUME,, LEVEL, IN STRAIGHT LINES WITHOUT DISTORTION AND GLEAN. B. INSTALL EAGH FIXTURE IN A MANNER RECOMMENDED BY THE FIXTURE MANUFACTURER AND APPROVED BY THE OWNER'S REPRESENTATIVE. UNDER THIS SECTION OF THE WORK, FURNISH AND INSTALL ALL ADDITIONAL CEILING BRACING, HANGER SUPPORTS AND OTHER STRUCTURAL REINFORCEMENTS TO THE BUILDING REQUIRE TO PROPERLY AND SAFELY SUSPEND FIXTURES, ALL AS APPROVED BY THE OWNER'S REPRESENTATIVE. G, FIXTURES IN AREAS OF EXPOSED DUCT AND PIPE WORK SHALL BE SUSPENDED TO AVOID CONFLICT WITH SAME, D. PENDANT FIXTURES SHALL BE PROVIDED WITH BALL ALIGNERS AND SWAY ADAPTERS. FIXTURE CHAIN SHALL NOT BE USED FOR SUPPORTING FIXTURES. E. BALLASTS: BALLASTS JUDGED BY THE OWNER'S REPRESENTATIVE TO BE NOISY, AND FAILED OR MALFUNCTIONING BALLASTS SHALL BE REPLACED AT OWNER'S EXPENSE, 2.02 FIXTURE SUPPORT - SUSPENDED CEILINGS . . . A. PROVIDE FOUR WIRE SUPPORTS FOR EACH SUSPENDED FIXTURE, SECURED TO THE BUILDING STRUCTURE INDEPENDENT OF THE CEILING SUPPORTING SYSTEM. END OF SECTION SECTION 16720:, FIRE ALARM SYSTEM BIDDER DESIGN -A5 REQUIRED 1.00 GENERAL 1.0 SCOPE OF WORK . A. PROVIDE A COMPLETE BIDDER DESIGN FIRE ALARM SYSTEM FOR THE TENANT SPACE TO INCLUDE, BUT SHALL NOT BE LIMITED TO: 1: COMPLETE SYSTEM DESIGN. THIS SHALL INCLUDE COORDINATION OF LANDLORD AND L JURISDICTIONAL REQUIREMENTS. 2. DEVELOP PERMIT SUBMITTAL DOCUMENTATION, INCLUDING SHOP DRAWINGS AND BATTERY 2. CALCULATIONS. 5. ALL WORK, ITEMS, ARTICLES, MATERIALS, EQUIPMENT, WIRING, AND RACEWAY FOR A 5. COMPLETE AND OPERATIONAL SYSTEM, 4. SYSTEM TESTIN, DEMONSTRATION, AND TRAINING. 5. WARRANTY. . 6, ALL. DOCUMENTATION REQUIRED BY NFPA. B, SUBMITTALS -- BIDDER DESIGN CONTRACTOR SHALL PROVIDE ALL SUBMITTALS AS FOLLOWS:. I. SHOP DRAWINGS AND PRODUCT DATA SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL OF DEVICE LOCATIONS AND FINISH. 2, SUBMIT ALL DOCUMENTATION TO LANDLORD AND LOCAL JURISDICTION AS REQUIRED FOR APPROVAL. AND TO OBTAIN PERMITS, THIS SHALL INCLUDE, BUT IS NOT LIMITED TO, SHOP DRAWINGS, BATTERY CALCULATIONS, LISTING INFORMATION, AND PRODUCT DATA. 1.02 CODES AND STANDARDS . A. TENANT SYSTEM SHALL BE IN ACCORDANCE WITH ALL .JURISDIGTIONAL CODES, AND SHALL BE IN COMPLIANCE WITH THE LANDLORD'S STANDARDS AND REQUIREMENTS. 1.03 APPROVED CONTRACTOR AND INSTALLER . A. ALL WORK RELATED TO THE TENANT FIRE ALARM SYSTEM INSTALLATION SHALL ESE PERFORMED BY A LANDLORD APPROVED CONTRACTOR, B. ALL WORK REQUIRED TO BE PERFORMED BY THE LANDLORD OR THE LANDLORD'S CONTRACTOR SHALL BE AT THE EXPENSE OF THE TENANT FIRE ALARM CONTRACTOR. . C. TIE -IN AT LANDLORD'S FIRE ALARM PANEL, LOCATED IN THE FIRE CONTROL ROOM, SHALL BE PERFORMED BY LANDLORD'S APPROVED FIRE ALARM CONTRACTOR. 1.04 DEVICE COORDINATION A. FIRE ALARM SYSTEM DEVICES, NOTES, AND RELATED INFORMATION SHOWN ON THE ELECTRICAL PLANS ILLUSTRATES THE INTENT OF DEVICE LOCATIONS AND INSTALLATION REQUIREMENTS, AND SHALL NOT CONSTITUTE A COMPLETE FIRE ALARM SYSTEM !DESIGN. BIDDER DESIGN CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE EXACT SYSTEM REQUIREMENTS WITH LANDLORD AND JURISDICTION, . B, FIRE ALARM SYSTEM INSTALLER SHALL COORDINATE WITH ARGHITEGTURAL AND ALL OTHER TRADES FOR PROPER PLACEMENT OF DEVICES TO ELIMINATE CONFLICTS WITH OTHER SYSTEMS. 2.00 PRODUCTS . 1.01 DEVICES AND EQUIPMENT A. ALL WIRING, DEVICES, AND EQUIPMENT SHALL BE NEW AND COMPATIBLE WITH LANDLORD'S EYTEM. . . . B. ALL DEVICES AND EQUIPMENT SHALL BE U.L. LISTED, FM APPROVED, AND LABELED FOR FIRE ALARM SYSTEM USE. . AUDIBLENISUAL DEVICES, IF REQUIRED; SHALL BE WHITE IN COLOR AND CEILING MOUNTED, UNLESS NOT ALLOWED BY LANDLORD OR .JURISDICTION. IF CEILING MOUNT DEVICE ARE NOT ALLOWED BY JURISDICTION OR LANDLORD, PROVIDE THE REQUIRED WALL MOUNT DEVICES, D. PULL STATIONS, IF REQUIRED, SHALL BE ('"LUSH. . E. FOR INSTALLATIONS REQUIRING COMMUNICATOR OR DIALER, PROVIDE REQUIRED PRIMARY AND SECONDARY TELEPHONE LINES TO CONTROL PANEL AND PROVIDE 120 VAC DEDICATED BRANCH CIRCUIT AS REQUIRED FOR POWER, 3.00 INSTALLATION 1.01 INSTALLATION SHALL BE IN COMPLIANCE WITH LANDLORD AND JURISDICTIONAL REQUIREMENTS, 1.02 INSTALLATION SHALL BE 11s1 ACCORDANCE WITH REQUIREMENTS OUTLINED IN TENANT DESIGN CRITERIA MANUAL. 1.03 WIRING . . A. AT AREAS THAT ARE WITHIN PUBLIC VIEW, ALL FIRE ALARM CABLING SHALL BE RUN IN EMT. B. AT NON - PUBLIC AREAS, CABLING MAY BE RUN EXPOSED ABOVE 10' A.P.F, UNLESS LANDLORD /JURISDICTION REQUIRES METALLIC RACEWAY. IF SO, PROVIDE REQUIRED RACEWAY. FOR CABLING BELOW 10' A.F.F., RUN CONGEALED IN WALL OR IN RACEWAY. 1.04 CEILING MOUNT DEVICES A. AT AREAS WITH GINS OR ACT CEILING, PROVIDE REQUIRED BAGKBOX AND FLUSH MOUNT DEVICE IN CEILING, . B. AT AREAS OPEN TO STRUCTURE, PROVIDE APPROPRIATE BAGKBOX ATTACHED TO STRUCTURE WITH SURFACE MOUNT DEVICE. FOR AUDIBLENISUAL DEVICE SUPPORT FROM STRUCTURE WITH 5/8" THREADED ROD WITH DEVICE AT THE REQUIRED. ELEVATION. 1,05 COORDINATION A PRIOR TO INSTALLATION, INSTALLER SHALL REVIEW WITH THE LOCAL JURISDICTION AND THE LANDLORD, THE FIRE ALARM SYSTEM DEVICE LOCATIONS, INSTALLATION SHALL NOT OGGUR UNTIL APPROVAL OF LAYOUT IS OBTAINED BY BOTH AGENCIES AND COORDINATED WITH ARCHITECT. B. IF CEILING MOUNTED AUDIBLE/VISUAL DEVICES ARE NOT ALLOWED By THE LOCAL JURISDICTION, NOTIFY ARCHITECT, 1.06 FIRE ALARM SYSTEM BIDDER DESIGN CONTRACTOR :,HALL BE RESPONSIBLE FOR PROVIDING ALL RACEWAY 'REQUIRED FOR THE FIRE ALARM SYSTEM INSTALLATION. . 4.00 TESTING AND CLOSEOUT 1.01 . PROVIDE A COMPLETE SYSTEM TEST AS REQUIRED 15Y NFPA "12, AND THE LANDLORD. 1.02 TEST ALL GONDUGTORS AS REQUIRED IN NFPA "12, CHAPTER 1. 1.03 CONTRACTOR SHALL COMPLETE THE INSPECTION AND TESTING FORM IN NFPA '72, FIGURES 1- 5,2,2. 1.04 SUBMIT ALL TESTING AND INSPECTION REPORTS, SHOP DRAWINGS, AND AS -BUILT DRAWINGS TO OWNER AND AUTHORITY HAVING JURISDICTION AS REQUIRED BY NFPA '72, REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC 203 City Of Tukwila BUILDING DIVISION.. COPYRIGHT NOTICE; These drawings and specifications are copyrighted and subject to copyright protection as an "architectural work" under sec, 102 of the copyright act, 17 u.S.C. As amended december 1990. The protection Includes, without limitation, the overall form, arrangement and composition of spaces, and elements of the design, Under such protection, unauthorized use of these drawings and specifications may result in cessation of construction, building seizure, and /or monetary liability, o .w. CO '. wo.� IV 14 cri 4.. 4 W 03 (1) t),2 rN 112 LA z 0 Pim W J H V W J W 0 8 OCg P LU s10g w WO'� LLJ Zap W S'ENTI 23 $1 z • O • crs F +1 480 998 7223 0 co o uu 01 o CO 4V. a CC g 1 en a 41 C!C 0 1- . 0 RECEIVE VE AUG 21 2008 PERMIT CENTEF DATE: SCALE: DRAWN BY: 08,14,0a. SHEET: I /4s =11-0". PROJECT No.: STAFF E501 TME30801 a