HomeMy WebLinkAboutPermit EL08-1213 - 16901 SOUTHCENTER PARKWAY - VACANT SPACEVACANT SPACE
16901 SOUThCENTERPY
ELO8-1213
CitAbf Tukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 2623049011
Address: 16901 SOUTHCENTER PY TUKW
Suite No:
ELECTRICAL PERMIT
Permit Number: EL08 -1213
Issue Date: 09/15/2008
Permit Expires On: 03/14/2009
Tenant:
Name: VACANT SPACE
Address: 16901 SOUTHCENTER PY , TUKWILA WA
Owner:
Name: OCM ESCROW ADMINISTRATION Phone:
Address: 1717 MAIN ST 8TH FL- ESCROW , DALLAS TX
Contact Person:
Name: CLINT MCCUBBIN Phone: 425 -377 -1514
Address: 4314 106 AVE SE , EVERE'IT WA
Contractor:
Name: NORTHLAND ELECTRIC INC Phone: 425 377 -1514
Address: 4314 103 AV SE , EVERE TWA
Contractor License No: NORTHEI21879 Expiration Date: 03/31/2009
DESCRIPTION OF WORK:
INSTALL NEW LIGHT FIXTURES AND OUTLETS IN NEWLY CREATED TENANT SPACE. ADD NEW
SERVICE AND METER IN SPACE
Value of Electrical: ' $23,000.00
Type of Fire Protection:
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected:
National Electrical Code Edition:
$574.00
2005
Date: 9.....I -o
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this pe_ 't does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or th
Signature:
Print Name:
work. Imo thorized to sign and obtain this electrical permit.
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -1213 Printed: 09 -15 -2008
Parcel No.: 2623049011
Address:
Suite No:
Tenant:
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
16901 SOUTHCENTER PY TUKW
VACANT SPACE
PERMIT CONDITIONS
Permit Number:
Status:
Applied Date:
Issue Date:
EL08 -1213
ISSUED
09/08/2008
09/15/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Date:
doc: Cond -Elec
EL08 -1213 Printed: 09 -15 -2008
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http: //www. ci. tukwila. wa. us
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
/ King Co Assessor's Tax No.: 2.1,2101-t
/
Site Address: /t ?O .SD £.(H CEAn -F-F_ PEW
Tenant Name: 773'13'— V/XC4* SQQL
Property Owners Name: CSC HO
Mailing Address: „2yyz /s (A/ %}/,Q // S T �E%4/ E
City State
Suite Number:
New Tenant:
Floor:
Yes
9o[(
❑
..No
Zip
CONTACT PERSON — :Wdotdo we contact when your perinii is ready to be ssued
•
Name:
(-LN% t C KIu468 //1( Day Telephone: l�i�/r'
W State Zip (DS-
Mailing Address: V.1/ /03 '4) A F .S E- Ey E2 ) 1
City
E -Mail Address: 4''HAWk [O VEQ_jZdt'r )/E'/ Fax Number:
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
j\) 0 t H)A-A/9 E
Afrtc
Contact Person: &I E.-
E -Mail Address: S%4,Y/�
Contractor Registration Number: Moat-1E-12- 1 8 /
City State Zip
Day Telephone: ' , ,3'1 7 — 117 7
Fax Number: :? /V
Expiration Date:
Valuation of Project (contractor's bid price): $ O a / /
Scope of Work (please provide detailed information): j iL/ ) / A l / i� L- / 6 /1
A-
A-PD •tt-,) \CIEJ2 -v /c.- r ,s-P4 cc / rger
Will service be altered? 'X Yes ❑ No
Type of Use:
Type of work:
New ❑ Addition ❑ Service Change
❑ Low Voltage ❑ Generator ❑ Fire Alarm
Property Served by:
ikPuget Sound Energy
❑ Seattle City Light
H:lApplieations\Forms- Applications On t1n64 -2007 - Electncal Permit Application -doc
bh
Adding more than 50 amps? Yes , No
❑ Remodel ❑ Tenant Improvement
❑ Telecommunication ❑ Temporary Service
Page 1 of 2
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
Value of Construction – In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review – Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONT CTOR:
Signature: CrrG��
Print Name: e,C/, /Lf �� / — Cm Q a
Mailing Address:I S/7 / Oi' AVE_ £ E— EU €ar
City State Zip
Date: / �� 8J
Day Telephone: Ws- % f% /� y
Date Application Accepted: 94-.....06
Date Application Expires: 3 – g__00!
Staff Initials:
H:1Applicationeforms- Applications On Line4.2007 - Electrical Permit Application.doc
bh
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 2623049011 Permit Number: EL08 -1213
Address: 16901 SOUTHCENTER PY TUKW Status: PENDING
Suite No: Applied Date: 09/08/2008
Applicant: VACANT SPACE Issue Date:
Receipt No.: R08 -03184
Initials: WER
User ID: 1655
Payment Amount: $574.00
Payment Date: 09/08/2008 03:50 PM
Balance: $0.00
Payee: NORTHLAND ELECTRIC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 32947 574.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
ELECTRICAL PLAN - NONRES
000.322.101.00.0 459.20
000.345.832.00.0 114.80
Total: $574.00
doc: Receiot -06 Printed: 09 -08 -2008
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
-6.0g iti3
PERMIT NO.
(206)431 -3670
Project:
SPIO
Type of Inspection:
z 'Ov
Address:
I,g90 l 5
k, u Qs.i •
Date Called:
--
Specia nstructions:
Date Wanted:
D
O5'
a.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Inspector:
2±0NFE
E
Date: 03/05./07
❑ $60.00 REI EQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
nam6en d.sasw4ows- aadr u.gettit-.
//
INSPECTION RECORD
Retain a copy with permit
(ifig '-1213
1 PECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 12-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: V'Ac.AJT 3PAU
Type of Inspection: 7 3
C Addres
1661 0 1 p •
Date Called:
Special Instructions:
Date Wanted:
0 2 Z3
6331.7.
rI
Phone No:
181Approved per applicable codes.
EJCorrections required prior to approval.
'COMMENTS:
Q.K. ceiu.Jr, c0464c
R 0 41/4 14
Inspector: i;/ a&VAi6C
'- /
Date: a ;/03 o
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee mat be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
INSPECTION RECORD
Retain a copy with permit
lux- /24
PERMIT NO.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: IACfirtI SP
T
Type of Inspection:
7002--
Address:
/0°1 SIn#C,Ift• P •
Date Called:
Special Instructions:
Date Wanted:
iO/Z f
yl
14
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
ikAkoN\k, ()Yz tvr
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
AA X11 _ r4_O�_ .(/ - -- = T"ii96:�i _ .rua.....eiMigenr6a -�.s_
2-
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION V-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
tto -tit)
Project: ijA.L,,JT 5r,,040,6
AG
Type of Inspection:
7A�3
E!�
Address:
Vit o l Sri crik Pi -
Date Called:
Special Instructions:
Date Wanted:
! 3°
Q�
a.m.
p.m.
Requester:
Phone No:
❑ Approved per applicable codes. ['Corrections required prior to approval. ,
COMMENTS:
Rt
0.14. - �v C &J6-k. ro&
Inspector: —1;1 66"Wci\
Date:
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION 12'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (6)431 -3670
INSPECTION RECORD
Retain a copy with permit
cw,- 13
PERMIT NO.
Project: V Attie. 5 P Ice
Type of Inspection:
/003
Address:
16101 5114 ci.Pl -
Date Called:
Special Instructions:
Date Wanted:
9
.
a124.
Requester:
Phone No:
0 Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Pr
of %kisv4 alp
E.6S-Trzoterti /Ccb.
W
- R STS 001 Y r+ 9t-%T5
Inspector:
Date: (//2 b/a?
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: EL08 -1213 DATE: 09 -08 -08
PROJECT NAME: VACANT SPACE
SITE ADDRESS: 16901 SOUTHCENTER PY
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:i3 I
B ing t7i "vision
ii4t5
Public Works
n
Fire Prevention
Structural
Planning Division
n Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 09-11 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS R UTING:
Please Route Structural Review Required n No further Review Required
REVIEWER'S INITIALS:
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑ Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 10 -09 -08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2.28 -02
Untitled Page
•
•
Page 1 of 2
Electrical Contractor
A business licensed by LW to contract electrical work within the scope of its specialty.
Electrical Contractors must maintain a surety bond or assignment of savings account.
They also must have a designated Electrical Administrator or Master Electrician who is a
member of the firm or a full -time supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent
Company
NORTHLAND ELECTRIC
INC
4253771514
4314 103RD AVE SE
EVERETT
WA
98205
SNOHOMISH
CORPORATION
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Previous License
Next License
Associated
License
Specialty 1
Specialty 2
600344369
ACTIVE
NORTHEI21879
ELECTRICAL
CONTRACTOR
10/29/1979
3/31/2009
MCCUBCM970RH
GENERAL
UNUSED
MASTER ELECTRICIAN INFORMATION
License MCCUBCM970RH
Name MCCUBBIN, CLINTON M JR
Status ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
HECKMAN, DAVID G
01/01/1980
MCCUBBIN, CLINT M JR
01/01/1980
HECKMAN, DAVID G
AGENT
01/01/1980
Bond Information
II Bond 1 Bond I Effective I Expiration 1CanceIImpaired1 Bond I Received
https:/ / fortress. wa. gov /lni/bbip/Detail.aspx ?License= NORTHEI21879
09/1 5 /2008
ELECTRICAL SYSTEM
16901 SOUTHENTER PARKWAY
TLJKWILJ\. WA. 98188
121
bo
Abbreviat
REQUIRED FOR: i
Mechanical
D Electrical
Plurnbin
iGas Piping
City . f 'Tukwila
B :"Il..Dli ' '
Ii-e'9E1i11NS
N(, hlrine`; rnslrlr to th .inn
of t ".!()rk <�3ithol,t prior aprtro;; :1 of
T ,.4k'vIIa IPi.lildlr1cj Division
NOTE: ReviFions will rriquire a new r* ri s?!hr t'rtI
and may include additional plan resPi•w.t
0
c
anode t:ii.:...,,
51: ✓3 �.fi
tihr..zi Dr,
. Ii1,Mi i .
5r=ader El d
FO
LIGHTING
FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE
-(:)- FIXTURE CEILING MOUNTED
ao FIXTURE WALL MOUNTED
O
FIXTURE RECESSED CAN
TABLE LAMP
E FIXTURE SUPPLIED FROM EMERGENCY CIRCUIT
BC EXIT SIGN - DIRECTIONAL ARROWS AS INDICATED, SHADED SIDES
ILLUMINATED
EMERGENCY WALL MOUNTED LIGHT
EMERGENCY CEILING MOUNTED LIGHT
WALL PACK FIXTURE WALL MOUNTED
KD
SWITCH - SINGLE POLE SUBSCRIPTS a,b, etc., DENOTES CIRCUIT
CONTROLLED
3 WAY SWITCH
24 HOUR TIMER
SMOKE DETECTOR
SMOKE DETECTOR - WALL MOUNTED
RECEPTACLES
SINGLE RECEPTACLE 120V
4 DUPLEX RECEPTACLE 120V, "D" = DEDICATED CIRCUIT
DUPLEX RECEPTACLE 120V, MOUNTED 3" ABOVE COUNTER BACKSPLASH
• ,t� DOUBLE DUPLEX RECEPTACLE 120V
TWIST LOCK RECEPTACLE 120V
DUPLEX RECEPTACLE 120V, EMERGENCY CIRCUIT
DOUBLE DUPLEX RECEPTACLE 120V, EMERGENCY CIRCUIT
SPLIT WIRED RECEPTACLE, 120V, TOP SWITCHED
SPECIAL RECEPTACLE ( TYPE AS NOTES)
FLUSH FLOOR OUTLET (DEVICES AS INDICATED)
COMBINATION OUTLET (DEVICES AS INDICATED)
DUPLEX RECEPTACLE - ISOLATED GROUND TYPE
DUPLEX RECEPTACLE - GROUND FAULT CIRCUIT INTERRUPTER TYPE
II;
I G
GFP
DRAWING INDEX
E0.1 TITLE SHEET
E1.1 FLOOR PLAN LIGHTING
E1.2 FLOOR PLAN POWER
E2.1 ONLINE SERVICE DIAGRAM
y
J-
0
ELECTRICAL RIER
FUSED SWITCH
CIRCUIT BREAKER
DRAWOUT CIRCUIT BR
CIRCUIT BREAKER -
AKER
ROUND FAULT PROTECTION
CABLE TO BUS CONNECTION
FUSE OR CURRENT LIMITER
GROUND CONNECTION
IDENTIFICATION SYMBO_ FOR FEEDER SIZES
TRANSFORMER
WATT -HOUR METER
TRANSFER SWITCH
ENGINE - GENERATOR
XXX AVAILABLE SHORT CIRCUIT CURRENT
e eE
/01 MOTOR CONNECTION S
/CY MOTOR CONNECTION 3
EQUIPMENT
PANEL - 208 VOLT SYSTEM
PANEL - 480 VOLT S
YSTEM
EQUIPMENT CONNECTIO
TRANSFORMER
ABBREVIATIONS
N, E = EMERGENCY POWER
NGLE PHASE
PHASE
ACH ABOVE COUNTER HEIGHT
AFF ABOVE FINISHED FLOOR
AFP ARC FAULT PROTECTED
AG ABOVE GRADE
A, AMP AMPERE
ATS AUTOMATIC TRANSFER SWITCH
AWG AMERICAN WIRE GAGE
CB CIRCUIT BREAKER
CKT CIRCUIT
CTB COMMUNICATIONS TERMIN L BOARD
DED DEDICATED
DW DISHWASHER
EWC ELECTRIC WATER COOLER
FA FIRE ALARM
FBOIC FURNISHED BY OTHERS,
INSTALLED BY CONTRACT R
FT FEED THRU
G, GND GROUND
GD GARBAGE DISPOSAL
GFI, GFCI GROUND FAULT CIRCUIT I TERRI. PTER
HP HORSEPOWER
IH INSTA -HOT WATER DISPENSER
J -BOX
MW
MB
M LO
N
NIC
PNL
R
RO
RECEPT
REF
SPECS
SW
SWBD
TELE
TYP
V
VP
W
WP
XFMR
0
JUNCTION BOX
MICROWAVE
MAIN BREAKER
MAIN LUG ONLY
NEUTRAL
NOT IN CONTRACT
PANEL
RACEWAY
RACEWAY ONLY
RECEPTACLE
REFRIGERATOR
SPECIFICATIONS
SWITCH
SWITCHBOARD
TELEPHONE
TYPICAL
VOLT
VANDALPROOF
WIRE OR WATT
WEATHERPROOF
TRANSFORMER
PHASE
ELECTRIC HEAT
BASEBOARD HEATER CONNECTION (KW INDICATED)
CONTROL
FUSED SWITCH (FUSE RATING INDICATED)
0' DISCONNECT SWITCH
• MOTOR STARTER - MAGNETIC
J COMBINATION MOTOR STARTER DISCONNECT SWITCH
® THERMOSTAT
® TIME CLOCK
Pc PHOTOCELL CONTROL
El ENCLOSED CIRCUIT BREAKER
GENERAL NOTES
1. COMPLY WITH NATIONAL ELECTRICAL CODE 2005 EDITION AND WAC 296 -46.
2. THE LOCATIONS OF ELECTRICAL DEVICES OR LIGHTING FIXTURES INDICATED ON
ARCHITECTURAL PLANS ELEVATIONS OR SECTIONS TAKE PRECEDENCE OVER
LOCATIONS INDICATED ON THE ELECTRICAL DRAWINGS.
3. REFER TO THE ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LIGHTING
FIXTURE LOCATIONS.
4. HVAC EQUIPMENT SHOWN IN APPROXIMATE LOCATIONS. REFER TO HVAC PLANS
FOR EXACT LOCATIONS.
6. ALL NEW WIRE IS #12 THHN /THWN COPPER UNLESS OTHERWISE NOTED
6. FUSE /PROTECT ALL MECHANICAL EQUIPMENT PER MANUFACTURER'S
RECOMMENDATIONS AND CODE REQUIREMENTS.
7. ALL UTILITY ROUGH -IN WILL BE COORDINATED WITH LOCAL UTILITY COMPANIES.
8. COORDINATE AND OBTAIN MAXIMUM AVAILABLE FAULT CURRENT FROM POWER
COMPANY. ALL SERVICE EQUIPMENT WILL BE RATED AND COORDINATED FOR
MAXIMUM AVAILABLE FAULT CURRENT.
9. PROVIDE SERVICE GROUNDING PER NEC.
10. PROVIDE ASTROLOGICAL TIME CLOCK TO WORK ALL BUILDING AND SITE
EXTERIOR LIGHTING.
WORK DEFINITION
FLAG NOTE
REVISION SYMBOL
X
ELECTRICAL DETAIL SYMBOL
OUTLET MOUNTING HEIGHTS
SPECIAL OUTLET HEIGHTS ARE SHOWN ON THE ELECTRICAL DRAWINGS OR
ON THE ARCHITECTURAL DRAWINGS. IF SPECIAL OUTLET HEIGHTS ARE NOT
SHOWN OR REQUIRED, THEN LOCATE OUTLETS AS NOTED BELOW. OUTLET
HEIGHTS ARE MEASURED FROM THE FINISHED FLOOR TO THE CENTERLINE
OF THE OUTLET UNLESS OTHERWISE NOTED.
RECEPTACLES
LIGHT SWITCHES
CLOCK OUTLET
PANELBOARDS
+18 INCHES VERTICAL
+4 FEET SET VERTICAL
+6 FEET, 8 INCHES
+6 FEET TO TOP OF PANELBOARD
VICINITY MAP
F' COPY
Permit No
Pin r rcvIOw approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. flece!pt
01 approved FiP py and conditions is ckno leciged:
City of Tukwila
SIM Oil° DIVIVON
Lea htin! Summa
LTG -SUM
Note new automatic da? 11C9t1tiF3 . ocou ancY sensor, and cth control ret tairet eats of `.section 1513. as a liicatble.
Pro) '.ct Info
Roject .AdrJf ss • ,. ,.
Cate 9/7/2008
r; 2008
Applicant f ckune..: •, ' ` , ' . , . '
For Efurii: erg Department t_ e
Applicant Address- :•,.,. ,..,,.,r ..:. :...... .. ...:.
Applicant Phone; < . . < • < . < > < ... , < < , .
T l {{,
rc)ject l.i)escrrptic)u New Building [3 Addition iJ Alteration el>ig. >5,000 scl.ft, (auto shutoff req [J man; In<1t.a(i ,:
Refer to SEC Section 151:3 for vontrot and commissioning requirements.
(.'otltpititnce Option
t (_) p, escriptive j j Lighting Power Alo air e 1 }' Systems 3�\ir..slysirs t--•'} Clear
( See Qualification Check hst (over). tnd Cate; e7t escriptivee & I.PA spaces clearly on piteans.) '
Total Allowed Covered Parking. Watts
Alteration Exceptions ep ."ions
(check appropriate box
fl rtc, changes are being made to tree lighting
`- °) < Cwi)'rs of fixtures new , installed lighting `T' e3ttc3C ;3 not increased, and Table 15-1 C3sE'. 3;5 not
: Maximum Allowed 'Lighting Wattage (Interior)
Location
(floc•rfrcont no,)
(-;f:c,;iUPanoy scrPptkm
105-
.R tail Area
Allow ed
Watts per tt• ..,
1.50
Area ire ft" Allo,r> ed x Area
30:9,3.0 46.39, 5
From'l'ab{ 15-1 (over) - document tall exceptt¢zris on form E.:T(,', -L..PA Totals
Notes on l topoa d Lighting 9 Wattatae:
1 Brae nlant.Ff a,.ture3 s listed maximum input vW ettort'-. For bard -va fret! ballasts only, tlae
default table in the NREC Technical Reference Manual may ;also be used
2. include exit lights exceeding 5.0 waits per fixture.
3. List all fixtures. For exert-4A iiahtia o, note excesttion on auttlica le natures.
Proposed Lighting Wattage (Int.)
Location
( floortraoria no.)
Retail
.o9.0
46:39,5
Fixture l:. scriptiors
Nunter of
Fixtures
\Aloft*/
Fixture
A.1.
Total Proposed Watts may not exceed Total Aftow e•d W tts for Interior
Maximum Allowed Lighting Wattage (Exterior)
25
1.0
Watts
FY 1:.t;sed
0 x496.
95.0 960.5
X12. 0
Total Proposed Watts
84.0
3540.0
Location ttiora
covered Parking
f escription
No. of Fixtures
Allow ed Watts
per ft" or per it
0.2 =ft'
Area it r f to
or If for perimeter,
Allow '.d Watts
x tt (or x If)
Note: 2OD1 SEC (foes not :allow tr: din(k tote een cover d .ir- and ext kn.
Total Allowed Covered Parking. Watts
Open Parking
0.1 b \`r`ft'
Outdoor Areas
0,15 '\ +iift.
Total Proposed Watts toy not exceed To Allowed Watts for Exterior Total Proposed Watts
E(ldg. (by facade)
0..15 Wiff
Bldg. (by t) r irrt)
Note: choose either
the facade. area or the perimeter method, but not both.
7.5 Wilf
Total: Mewed €
ag. Exterior Watts
Proposed. Lighting Wattage (Exterior
Use mfgr listed astir > :frr rm k put wattage. Far fixtures w ith hard-wired ballasts
only, the default table In the NREC Technical Reference Manual may also be used.
Location
Fixture L scription
No. of Fixtures
Watts/ Fixture
Vklatt;a Ffoposed
Total Proposed Watts toy not exceed To Allowed Watts for Exterior Total Proposed Watts
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
SEP 1 2 2ni3
City Of Tukwila
BUILDING DIVISION
ECElV D
SEP 08 2008
PERMIT CENTER
LOB 1Z13
DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36"
r
LII
10011 North Fleetwood Street
Spoketrf-a, WA 99208
Phone.: (509) 466 -2936
Fox: (509) 466 -2937
email: spokaneofficet safeconsulting.biz
INSTALLING CONTRACTOR:
NORTHLAND ELECTRIC
4314 1031zZ• AVE_ SE_
EVERETT', WA. 98205
Phone: (425) 377 -1514
Fatx: (425) 377 -9414
0
aD
0
tz
0
0
Z
9
w
PERMIT SET
J
0
CO
0
SHEET TITLE:
Z
0
w
CO
m
0
z
J
0
m
(t)
DRAWN BY: Doug Burton
CHECKED BY: Adrian M. Steik
PLOT DATE:
09/07/2008
PROJECT NUMBER: 08-055
E0.1
SHEET NUMBER:
<EM>
CA;
(^)
105 -A 7
105 -A 9
105 -A 11
<Al
(A)
A>
A1>
(A)
CN;
(A)
;a)
A 1>
�D
(A)
-B 1
(A)
(A)
�rREVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
SE? 1 2 2000
City Of Tukwila
BUILDING _DIVISI..,
10011 North Fleetwood Street
.Spol<aine, WA 99208
Phone: (509) 466 -2936
Fci'c: (509) 466 -2937
email: spokaneoffice ®safeconsulting ,biz
INSTALLING CONTRACTOR:
NORTHLAND ELECTRIC
4314 1O3I2C7 AVE_ SE.
EVEIZET F, WA. 93205
Phone: (425) 377 -1514
Fctx: (425) 377 -9414
(PERMIT SET
[F
05 -B 2
LIGHTING
05 -B 4
105 -B 6
105 -B 8
( )
105 -B 10
SCALE = 1/4" ,1' -0"
RECEIVED
SEP 08 ZOOS
PERMIT CENTE
DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36"
DRAWN BY:
Doug Burton
CHECKED BY:
Adrian M. Steik
PLOT DATE:
PROJECT NUMBER:
09/07/2008
08 -055
SHEET NUMBER:
105 -B 7
HWT ABOVE CEILING
105 -B 1,3
105 -A
75KVA
XFMR
105 -B
> 105 -B 5
105 -A 2,4,6
105 -B 12
wP GFI
H 1 3F
1L_
101 -B 9
\--
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
12. 2003
City Of Tukwila
LDING pIV1$IQL
21 3
ECEWWE[
SEP 08 2000
PERMIT CENTEF
DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36"
10011 North Fleetwood Street
Spokcine, WA 99208
Phone: (509) 466 -2936
Faax: (509) 466 -2937
email: spokaneofficeesafeconsulting .biz
INSTALLING CONTRACTOR:
NORTHLAND ELECTRIC
4314 103FID AVE_ SE_
EVERE°Vrn, WA_ 98205
Phone: (42S) 377 -1514
Fcix: (425) 377 -9414
0
0
0\
0
z
0
5
W
(PERMIT SET
a]
0
Q� co
CCCO
CL
WQ
Z
W
U
J
�
0
/' (,-.2
SHEET TITLE:
0
LL
-n
DRAWN BY: Doug Burton
CHECKED BY: Adrian M. Steik
PLOT DATE:
09/07/2008
PROJECT NUMBER: 08 -055
E1.2
SHEET NUMBER:
T V3P
PA \7
105 -A
10DA vL
480
I- N) I -
0 0
Z 0 7 0
CA
75r<VA
7C8/120V
30, 4W
#4 CU
N
0 y
Z 0
NJ
01
0
PA \ -L
105 -8
200A vB
SERVICE AND PANEL SCHEDULES
SCALE = 1/4" -1' -0"
Panel NC R atin "101
PANEL SCHEDULE
Fad From Panel MOP
Panel:
1Ct5 -A
Main Bus 100A
Panel Location : Space 105
Fed Frorrr Panel MDP
: Space 105
Ckt, No,
Load Description
kva
Main Log
Trip Amps Phase
Trip Amps
100 amps
277/480v 3 -Phan+
Load Description
'00 amps 120/208 3 -Phase
CM. No
CIO. No,
Transforaner to Panel 101-8
15.31
00 A
30
6.07
1-IVAC grit
Trip Amps
2
4
Load Description
90
30
30
6. 07
6.07
2.50
4
30
A
20
0 ®
.
6
7
Lighting
1.44
20 A
W
2,50
f,
9
Lighting
1.,44
20 B
Bhow Window
2
NUMBER:
5
10
11
13
Lighting
MMIIMMEMEMMINMME
1.44
20 C
A
C
20
1.53
12
6
14
15
0.72
B
t
A
20
=
20
10
17
19
8
9
18
0.72
20
21
B
20
m--
B
Snow Window
Rooftop WP GPI
10
22
24
23
..
25
20
A
` 20
12
13
26
27
B
12
28
30
31
15
..
A
,,,
C
32
33
35
-
.
B
16
18
20
17
10
34
ry
21
3r
39
A
8
22
24
26
23
25
40
41
Total kva .
Connected Loads
10
63
18
21
m
Total kw µ
42
Total kw -
G
--
37.84
0.00
MEMMEMMEMEMEMMEMMEMMMMEME MEMMIIMMMEMEMMOIMMEMMIMMOIMM
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMIIIIIII
11111.1111111111111.11111111
0.00
0.00
0.00
Demand Loads 10.03
111=11
18 41
Total Amp
45.54
Panel:
Para€�I Ali P €iir €r .1 1£7K
INSTALLING CONTRACTOR:
NORTHLAND ELECTRIC
4314- 103Rt AVE_ SE.
EVERE1 V, WA. 98205
Phone;: (425) 377 -1514
Fnx: (42) 377 -9414
[DATE
09/07/08
PANEL SCHEDULE
rv1- in Bus 200.E
Panel Location
Fed Frorrr Panel MDP
: Space 105
105 -B
Main Lag"' ''
'00 amps 120/208 3 -Phase
CIO. No,
Load Description
kva
Trip Amps
Phase
Trip Amps
J
4
Load Description
Ckt, No,
1
Hot Water Heater
2.50
30
A
20
~ ho ii Window
co
U < co
Lt 00
CL
(r d
W
Z
W
C)
IN
H
(1)
0) :
N-C° is"
2 , .
3
W
2,50
30
B
20
1.53
PROJECT NUMBER: 08 ®055
Bhow Window
2
NUMBER:
4
5
General Receptacles
0.54
20
C
20
1.53
Show Window
6
7
General Receptacles
0.72
20
A
20
taov Window
8
9
General Receptacles
0.72
20
B
20
ME
0.18
Snow Window
Rooftop WP GPI
10
11
Bathroom Lights and Fans
0.50
20
C
` 20
12
13
A
12
14
15
,...
....,,,_.w,.
,,,
C
s
-
.
16
18
20
17
10
21
(
A
-
22
24
26
23
25
27
29
G
--
28
30
32
31
A
8
33
35
34
36
37
A
38
30
41
B
40
42
Total kw ~
Cnatnectod Loads
7.48 .. .
7.83
m
Total kw
15.31
0.00
0.00 . .
0.00
0.00
7.63
;Tonal kw
Demand Loads
7.48
Total Anal::
42.53
r NFPA REVIEWED FOR
DE COMPLIANCE
70 - NEC
LUUO
City Of Tukwila
,�BUI DffiG_DJVJSION
RECEIVED
SEP 08 20
PERMIT CENTER
DRAWING ONLY TO SCALE IF PLOTTED AT 24" X 36"
CO ,1 ;\mot,,.
10011 North Fleetwood
Spokane. WA
Phone.: (509)
Fcix: (509)
email: spokaneoffice @safeconsulting
/
�`��
Street
99208
466 -2936
466 -2937
.biz
INSTALLING CONTRACTOR:
NORTHLAND ELECTRIC
4314- 103Rt AVE_ SE.
EVERE1 V, WA. 98205
Phone;: (425) 377 -1514
Fnx: (42) 377 -9414
[DATE
09/07/08
z
05
w
CE
I-
w
I-
H
ww
J
4
■
1
co
U < co
Lt 00
CL
(r d
W
Z
W
C)
IN
H
(1)
0) :
N-C° is"
-
€J_I
El
~W
w
w
V)
(/)
W
J
D
0
W
1
0
CO
J
W
z
0.
0
W
>
DRAWN BY: boug Burton
CHECKED BY: Adrian M. Steik
PLOT DATE: 09/07/2008
PROJECT NUMBER: 08 ®055
SHEET
2
NUMBER: