Loading...
HomeMy WebLinkAboutPermit EL08-0128 - WESTFIELD SOUTHCENTER MALL - GODIVA CHOCOLATIERGODIVA CHOCOLATIER 555 SOUTHCENTER MALL ELO8-128 City.f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 555 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -128 Issue Date: 04/17/2008 Permit Expires On: 10/14/2008 Tenant: Name: GODIVA CHOCOLATIER Address: 555 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DEB SUBOTNIK Phone: 800 - 407 -7990 X581 Address: 11006 NE 41 DR , ICRKLAND WA Contractor: Name: PRO TECH ELECTRIC INC Phone: 206 - 931 -4173 Address: PO BOX 12755 , EVERETT WA Contractor License No: PROTi ri 934JC Expiration Date: 04/03/2009 DESCRIPTION OF WORK: PROVIDE NEW LIGHTING, CONNECT NEW EQUIPMENT TO EXISTING, INCLUDING THE EXISTING METERING EQUIPMENT Value of Electrical: $24,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: Date: $594.50 2005 Lt-n -og I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: „4/ Date: 7L/ f 2 -0e This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -128 Printed: 04 -17 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 555 SOUTHCENTER MALL TUKW GODIVA CHOCOLATIER PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -128 ISSUED 02/08/2008 04/17/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: !�� Date: U y (7 8 Print Name: / " ' c Off, doc: Cond -Elec EL08 -128 Printed: 04 -17 -2008 CITY OF TUKWIN Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httallwww. ci. tukwila. wa. us Electrical Permit No. G I_ F 126 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: \ Site Address: .5) \) 30c, _�h c' c' ( Suite Number: I C O floor: 1 Tenant Name: (- -)tY1 t , - C i t,oR New Tenant: Ild Yes ❑ ..No Property Owners Name: l _L.7)V t ci. Arcl N • Mailing Address: l 1(01 Li:), Iotal it C ".-K L),\, IL 10 Mkt '' l,-.o-, it q�.km . O-� Ql; �;QJ City J State Zip CONTACT PERSON -Who do we contact when your permit is ready to be issued i Name: 1 )c br -1n.t Day Telephone: E\c - &1g- -3clotc) k5Ei 1 Mailing Address: 1 0l4' ' l �-� yy i \ i X�1 � ll City State Zip (�5LE-Mail Address: ( u i (43 i _ (l t ct t OA, i ruz , 0 Ct kik Fax Number: Sid-- -CI( )( • ELECTRICAL CONTRACTOR INFORMATION 1 Company Name: - ` LAJ Mailing Address: City Day Telephone: Fax Number: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ .M0 -- Scope of Work (please provide detailed information): --0y7.0 t 7; (le ∎1 1N.L , (.:\�J_ r,) (� " ft. a (� c e a,D M,Lc rt �t . -5� R , l nC �srk t w tilR PA( c YFX 1 lJ Q . rL w Will service be altered? ❑ Yes oi No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light H: 1ApplicationsWomi-Appliations On Lmc'4 -22007 - Electrical remit Application.doc m Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESW NTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of constriction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: \ \c`C?(c Date: 7- 7 - Day Telephone: �� M Ll1 (9 X 1411 1? h cvv.ck, 0114 City State Zip Date Application Accepted: el_ g Date Application Expires: 6_9_09 IStaff Initials: Gip H:UpldicatiomWomu- Appluations On L 4 -21107 - Electrical Pamir Application.dnc bb Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -128 Address: 555 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/08/2008 Applicant: GODIVA CHOCOLATIER Issue Date: Receipt No.: R08 -01193 Payment Amount: $475.60 Initials: WER Payment Date: 04/16/2008 09:22 AM User ID: 1655 Balance: $0.00 Payee: MARKET CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11722 475.60 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 475.60 Total: $475.60 dor.• Raraint -CIS Printari. n4-16-200R • • ,{ . City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://wwwci.tukwila.wa.us Parcel No.: 6364200010 Address: 555 SOUTHCENTER MALL TUKW Suite No: Applicant: GODIVA CHOCOLATIER RECEIPT Permit Number: EL08 -128 Status: PENDING Applied Date: 02/08/2008 Issue Date: Receipt No.: R08 -00358 Initials: WER User ID: 1655 Payment Amount: $118.90 Payment Date: 02/08/2008 10:04 AM Balance: $475.60 Payee: DEB SUBOTNIK TRANSACTION LIST: Type Method Description Amount Payment Check 1662 ACCOUNT ITEM LIST: Description 118.90 Account Code Current Pmts ELECTRICAL PLAN -- NONRES 000.345.832.00.0 118.90 Total: $118.90 8282 02/08 0710 TOTAL 1296.37 doc: Receipt -06 Printed: 02 -08 -2008 INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: <ON1/4 C,u( ,-f T'F-/ . Type of Inspection: Cr) A�dddrreesss: "�' �+ pl [ -‘ j� ! �T I /�% } / F!'iV Date Called: /2/ Special Instructions: Date Wanted:, in Requester: 745-7 ,gf-C>lt'f E Phone No: Z%pioved per applicable codes. Corrections required prior to approval. COMMENTS: F/11:4 Ald tai s 4/6» 17,) 745-7 ,gf-C>lt'f E 1%Icl ciiF 7i 14,4 ''G i,t Inspector Ni 6110— 7/"H 1Date:6 /6/6 !' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 8 INSPECTION RECORD Retain a copy with permit `/2" INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le-, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: obi VA rn L r' Type of Inspect�6 � 0-0 Address. 5;1/ Vie -IN P44 ,/iA;V Date Called: Special Instructions: Date Wanted: � �/ a.m. Requester: Phone No: k4. pproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: do4... o/4- f- i,�l�l'- -- eiN2c/Ai ,a ss / /( /17/4)6 77-5r Inspe Date r/ / g, 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: 7 INSPECTION NO. INSPECTION RECORD Retain a copy with permit flogzcr PERMI NO. ti CITY OF TUKWILA BUILDING DIVISION A 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (2 06)43 1 -3670 Project: . j / Y/ C#OCUL-04 77(4. Type of Inspection: 7O? Address: 7,61 Date Called: Special Instructions: Date Wanted: �/2 7 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: pie) 0/4—pan, ‘-6i7-74)(;- Insp /Are aribile,671 Date` 7/t ff $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6 3 0 0 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: CGM'4 Qo c 61,1; ; Type of Inspection: / C A IVSpecial Date Called: Innstrruuctions: Date Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: a49_ rir)(g— i)Pk _-W <, -- f ,,A., /G%/ . l'v itgai S - ,; /" 6,7( � / i 1 A*c4, I : Z / 1 4 — ,i' fil 1 •1 / ( ti {,1/'. ,, y c 41r Ili/4Y: Inspec r' ./� (47..ex,enz76,9 Date:. 4,2/6 ID $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 0-442 Cr PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 4t- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: � /p� L d 6oh 9Pi c//7 /fA Type of Inspection: /, 7x63 A dre Date Called: Special Instructions: Date Wanted: a. m. Requester: Phone No: oved per applicable codes. Corrections required prior to approval. OMMENTS: p,J 14--- // (— /8-zs44r-4 Inspe r: fi/k Date: sy�� /e 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 1,1 INSPECTION NO. INSPECTION RECORD Retain a copy with permitift0r-/;. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Project: 1 ill C//46046 7/e-- Type of Inspection: 7 2 Address: M Date Called: Special Instructions: Date Wanted: 3--/r a.m Requester: Phone No: roved per applicable codes. Corrections required prior to approval. MMENTS: (-2/ .(-71 Inspector: 93id i 6i7F- -11 C ,Tl'Cl/ Date: ,",;?., Ger D $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: S INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 46 S---"/;1 r PERMIT NO. (206)431 -3670 Pr ject: GO%A/ kin C/ftrcot 7 '4A- Type of Inspection: -7Ort a ess 4 Date Called: Instructions: Date Wanted: `? „ IGI-Special Requester: Phone No: proved per a plicable codes. OMMENTS: Corrections required prior to approval. 1 (A)I 2L 1' Inspe Date: . ,/_, £fi /G, 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: (Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. 1- (206)431 -3670 Project: 66AI VII 41wi 7/- Type of Inspection 6-6 711-1" W / Ti tdIt 7 /1 1O/ (/A)t Address \5-c-1 6.0-an MGG Date Called: cac-G.Ii .E 72_// /ci, f_ JC w/111 It1 /7' , Special Instructions: Date Wanted C 7 Cam+ p.m. Requester: Phone No: Approved per applicable codes. fl 51 Corrections required prior to approval. 1. COMMENTS: 0 /MUG A7E ,ffl1T g - c 4 i E s / UM 6-6 711-1" W / Ti tdIt 7 /1 1O/ (/A)t s pflpa/t f fry; - 14)'7- iN "XI f &/cTA' •2x ,(� cac-G.Ii .E 72_// /ci, f_ JC w/111 It1 /7' Inspe ?fl' /Rge( /1 Date; /60ir $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit cog- its h PERMIT NO. (206)431-3670 Project: Li QD A /t Type of Inspection: 70q Address: 553_ 4M j Date Called: Special Instructions: Date Wanted: a.m p.m. Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: V Date: 01 9 O El $58.00 REINSPECTION FEE RI=QUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ARMOUR UNSDERFER ENGINEERING, INC 13456 SE 27th PI., Suite. 200 Bellevue, WA 98005 (425) 614 -0949 Fax (425) 614-0950 STRUCTURAL CALCULATIONS FOR: GODIVA Cizocolatier Godiva Southcenter Mall Tukwila, WA Client: MODA4 Design 4325 Tam 0 Shanter Way Dayton, OH 45229 ID : 11 -10 -09 I By Brian Unsderfer SE, SECB INCOMPLETE LT R# FILE COPY ELOS- 11.$ RECEIVED FEB 2 8 2008 PERMIT CENTER AUE No. 8077 Date: 02/21/2008 Godiva Southcenter Mall Support of New Condensing Units 1 Unit at Floor above 1 1 Gravity Design of Soffit Unit Weight Wt = Framing = ITotal = 400.0 LBS 50 LBS 450 LBS No. Vert. = 4 T / Vert. = 112.5 LBS Try: 0.5 IN Diameter Rod As = ft= 0.196 INA2 572.96 PSI Rod is OK by Inspection !Use : 0.5 IN Diameter Rod 1 Try Angles: 3x3x1/4 S= I= 0.577 In ^3 1.24 I N^4 M = 450 LBS FT fb = 9359 PSI �I R Al Plan of Support 1 I P = 400.0 LBS 1 I 14 L= 4.5 FT Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (206) 614 -0949 Project: Godiva Southcenter Mall Pg. No: ME1 Address: Tukwila, WA Date: 2/21/08 Client: MODA4 Design Job No.: 8077 Lateral: 0.319 x W Lat WS = 0.228 x W Wt = 450 LBS Lateral Load= 102.4 LBS Lat per brace = 51.22 LBS (Braces OK by Inspection ANGLE To V8' [, I V2' TOP GIORD V0' (E) METAL DFLK TYP UNISTRUT TO TOP FLANGE ROM UNISTRUT BETWEEN REAM. MIN OF (2) ASSEMBLIES PER MECHANICAL UNIT UNISTRUT WOW NUT. TACK WELD NUT AFTER ROD INSTALLATION, TTP \-(E) BEAM PER PLAN r'\ V2°0 THREADED ROD WITH DOUBLE TAUT AT BOTTOM EOLATER AS R£OUIREP I V7 WODO UNISTRUT. SLOPE At AN ANGLE NOT GREATER THAN 1 TO I. ORIENTATE PER DET A L3'X3'5V4",TYP SECTION A -A ANGLE LOIPIECTIQI DETAIL OFTAN R BRACING PATTERN Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (206) 614 -0949 Project: Godiva Southcenter Mall Pg. No: ME2 Address: Tukwila, WA Date: 2/21/08 Client: MODA4 Design Job No.: 8077 0.2461 1 IBC Seismic 1 See Seismic Output 1 Ss= S1= 1.473 0.507 le = R= Site Class = ID v 1 Seismic Use Group I Design Category D 1.0 4.0 hn = Ct = Standard -Occupancy Buildings 35 FEET 0.02 Fa = Flt = 1.00 1.50 Sms = 1.473 Sm1 = 0.761 Sds= Sd1= 0.982 0.507 See procedure IBC 1617.4 lCs = T= 0.288 Seconds lCs max = 0.4401 Cs min = Cs min = Not Applicable Cat. E & F 0.043 Cat. A - D (Cs min = 0.0431 ICs = 0.246 W 1 1 See procedure ASCE 9.6.1.3 Non Building Systems 1 Ap = Rp = Ip = Fp = Fp max = Fp min = 1 2.5 1 0.32 Wp 1.57 Wp 0.29 Wp IFp= 0.319 W z= h= 18 FEET 35 FEET Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (206) 614 -0949 Project: Godiva Southcenter Mall Pg. No: SEIS 1 Address: Tukwila, WA Date: 2/21/08 Client: MODA4 Desian Job No.: 8077 Conterminous 48 States 2005 ASCE 7 Standard Zip Code = 98188 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Centroid Sa (sec) (g) 0.2 1.429 (Ss, Site Class B) 1.0 0.489 (S1, Site Class B) Period Maximum Sa (sec) (g) 0.2 1.473 (Ss, Site Class B) 1.0 0.507 (S1, Site Class B) Period Minimum Sa (sec) (g) 0.2 1.377 (Ss, Site Class B) 1.0 0.470 (S1, Site Class B) Armour Unsderfer Eng, 13456 SE 27th PL., Suite 200, Bellevue, WA 98005 (206) 614 -0949 Project: Godiva Southcenter Mall Pg. No: SEIS2 Address: Tukwila, WA Date: 2/21/08 Client: MODA4 Design Job No.: 8077 I/8° \I I /2° / TYP UNISTRUT 1/8n/1 I /2° \ TO TOP FLANGE ANGLE TO TOP CHORD (E) METAL DECK I/8° \ 1 1/8° V I I /2° 1/2° PI001 UNISTRUT BETWEEN BEAM. MIN OF (2) ASSEMBLIES PER MECHANICAL UNIT V(E) BEAM PER PLAN TRANSFORMER PER MECH (400 lb MAX) —., UNISTRUT PI010 NUT. TACK WELD NUT AFTER ROD INSTALLATION, TYP I /24 THREADED ROD WITH DOUBLE NUT AT BOTTOM 0,FISOLATER AS REQUIRED 11/2 1 1/2° 11/2° 1 I/2° (SK TRANSFORMER SUPPORT P1000 UNISTRUT. SLOPE AT AN ANGLE NOT GREATER THAN 1 TO 1. ORIENTATE PER PET A L3° X 3° X 1/4 °, TYP SECTION A -A ANGLE CONNECTION DETAIL DETAIL B BRACING PATTERN EXPIRES: 11 -10 -09 ARMOUR UNSDERFER ENGINEERING, INC. \ 13456 SE 27T1-1 PL., STE 200, BELLEVUE, WA 98005 \ 425 614 -0449 PROJECT: GOD IVA SOUTNCENTER MALL ENG: B.U. PG: SKI ADDRESS: TUKWILA, WA VER: CLIENT: MODA4 DESIGN DATE: 02 -21 -08 JOB NO: 8077 2006 Washington State Nonresidential Energy Code Compliance Form Interior Li l tin Sumrnar yz 2008 Washington State Nonresidential Energy Code Compliance Forms LTG-INT Project Info ProJect Address codiva Chocolatier - Southcenter Mall Date 1/24/2008 633 Southcenter, Suite 1020 For Building DesgagnILLis Sales Area 101 REVIEWED IE\ ED l CODE COMPLI NFPA / 0 - 1' 1 Seattle, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Project Description p � 0.50 Plans Incnuded require = MAR � A 2 20 �� � i ❑ New Building ❑ Addition ./ Alteration Refer to WSEC Section 1513 for controls and commissioning _ _ Compliance Option 0 Prescriptive Q Lighting Power Allowance Q Systems (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clea ,., _! 4n Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new. Installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 ** Area in ft2 Allowed x Area Sales Area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main Sales Floor 0.50 162.0 81.0 Restroom 103 Restroom 0.80 56.0 44.8 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1093.3 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Rxtures Watts/ Fixture Watts Proposed 101 Type 82 - Semi - Recessed Adjustable Fixture 6 40.0 240.0 101 Type SA - 6" Square Adjustable Fixture 4 44.0 176.0 101 Type SD - 6" Square Downlight 2 44.0 88.0 101 Type PA - Pendant - Exempt per Table 15 -1, Footnote 10 8 101 Type 82A - Semi - Recessed Adjustable Fixture 2 44 .0 88.0 102 Type SR - 4' Linear Channel Fixture 5 58.0 290.0 103 Type FC - Fan /Light Combo 1 60.0 60.0 101 Type 82 - Exempt per 1512.1 - Food Prep Area 4 101 Type B2 - Exempt per Table 15 -1, Footnote 10 4 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 942.0 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T-8), number of lamps In the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) In addition to the fixture, Tamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture b E 0 FILE COPY FEB - 8 2008 PERMIT CENTEF, CE EC 8 vela 9 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is other and fature answer Is checked, the number of factures In the space is not limited by Code. Clearly Indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 J Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elect tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. nit Lighting Power Allowance (LPA Use' - • LPA` (WIsf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stationsa 1.0 Cafeterias, fast food establishments', restaurants/bars5 1.3 Post office 1.1 Dormitory 1.0 Retail1e. retail banking, mall concourses. wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnaslaa, assembly spaces¢ 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hail" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified 'laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet fadlities and washrooms, elevator lobbies 0.8 ootnotes for Table 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 8) Reserved. 7) For conference rooms and offices Tess than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft2 may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window. provided that the display window is separated from the retail space by walls or at least three- quarter-height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED. tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only If the lighting Is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance. as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary LTG -EXT 2006 Washington State Nonresidential Energy Code Compliance Forms Project Info Pro) Addres:Godiva Chocolatier - Southcenter Mall Date 1/24/2008 Area (ft2), perimeter (If) or # of items 633 Southcenter, Suite 1020 For Building Department Use Seattle, WA 98188 Name: Appl. Name Appl. Phone Project Description New ❑ Addition ❑ Alteration -, Plans Induded Indicate controls (Sections 1513) including commissioning requirements on plans. 'Compliance Option QQ Lighting Power Allowance 0 Systems Analysis 0 Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 Iumens/W ❑ Controlled by motion Sensor Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the fighting ❑ Less than 60% of the fixtures new, Installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) , - . . Tradable Proposed Lighting Wattage Total Allowed Watts Use mfgr listed maximum Input wattage. For fixtures with hard -wired ballasts only, the default table In the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts! Fixture Watts Proposed , - . . owed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts Non - Tradable Locations T v Description Allowed Watts per ft2 or per If Area (ft)), perimeter (If) or # of items Allowed Watts x ft2 (or x 1f) Non - Tradable Proposed Lighting Wattat=e Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed aas ror category 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, 2006 Washington State Nonresidential and Transformer Permit Plans Checklist LTG -CHK Energy Code Compliance Forms Revised July 2007 Project Address Goaiva Chocolatier - Southcenter Mall 'Date 1/24/2008 (transformer The following information is necessary to check a permit application for compliance with the lighting, motor, and requirements In the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E -2.0 yea 1513.2 Area controls Maximum limit per switch E -2.0 no 1513.3 Daylight zone control Schedule with type and features, indicate locations no vertical glazing Indicate vertical glazing on plans No daylighting no overhead glazing Indicate overhead glazing on plans No overhead glazing yes 1513.4 Display /exhib /special Indicate separate controls E -2.0 1513.5 Exterior shut -off Schedule with type and features, Indicate location no (a) timer w/backup Indicate location No exterior ltg no (b) photocell. Indicate location No exterior ltg 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations Controlled by contactor and switches yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E -2 . o Contactor Cl no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yea I 1514 (Max. watts Indicate watts for each exit sign E -1.0 1 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps. ballasts, watts per fixture Attached AO 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts. watts per fixture No exterior ltg MOTORS (Section 1511) no 1511 [Mac El motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency I No motors over � TRANSFORMERS (Section 1540) yea 1540 Transformers Indicate size and efficiency E- 2.1,E•TP1 4.0 If "no" is circled for any question, provide explanation: February 13, 2008 • Ciz of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Deb Subotnik 11006 NE 41st Drive Kirkland, WA 98033 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -128 Godiva Chocolatier — 555 Southcenter Mall Dear Ms. Subotnik, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 8, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide structural and seismic engineering and details for the suspended transformer installation. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. 1 have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: EL08 -128 P:\Permit Center\Incomplete Letters\2008\EL08 -128 Incomplete Ltr t11.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 HERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -128 DATE: 02 -27 -08 PROJECT NAME: GODIVA CHOCOLATIER SITE ADDRESS: 555 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: Bt�i ingA(j/isioii3 n Public Works 5 Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: f� Incomplete DUE DATE: 02-28 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required n DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03 -27 -08 Approved Approved with Conditions F71 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -128 DATE: 02 -08 -08 PROJECT NAME: GODIVA CHOCOLATIER SITE ADDRESS: 555 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT : � I B i.ing +ivisio Fire Prevention Public Works n Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ Incomplete DUE DATE: 02-12 -08 Not Applicable [1 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: ,(2" VV. Of) LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg LJ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route C , Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-1 1 -08 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentslrouting slip.doc 2 -28 -02 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: EL08-128 • Response to Incomplete Letter # 1 111 Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: GODIVA CHOCOLATIER Project Address: 555 Southcenter Mall Contact Person: Deb Subotnik Summary of Revision: `)yn ; • oo2.4 a (4— Phone Number: aNe, -5 tc - P _ 'tECC -F1 D crTv eF TI 1KWIIA FEB 28 2008 WO, f •c'r� rngi Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on •- '0S \applications \forms - applications on Iinc\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electric or Plumber License Detail • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License PROTETE934JC Licensee Name PRO TECH ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602694961 Ind. Ins. Account Id AGENT Business Type CORPORATION Address 1 PO BOX 12755 Address 2 City EVERETT County SNOHOMISH State WA Zip 98206 Phone 2069314173 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/3/2007 Expiration Date 4/3/2009 Suspend Date Separation Date Parent Company Previous License PROTETE943PP Next License Associated License DAMMANC997RA Electrical Administrator Information License DAMMANC997RA Name DAMMANN, NICK C Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date DAMMANN, NICK 04/03/2007 DAMMANN, NICK AGENT 04 /03/2007 IBond Information I i Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= PROTETE934JC 04/17/2008 1 2 3 4 5 6 7 10 LIGHT FIXTURE SCHEDULE ELECTRICAL SYMBOLS NOT NOTE: ABBREVIATIONS, ETC. EARE DNECEDSS RILYLU EDM ON THE DRAWINGS. LAMP VOLTAGE ELECTRICAL ONE-LINE & RISER 'CIRCUITING & WIRING WIRING DEVICES & OUTLETS NOTES 7 5 3 HOMERUN TO PANELBOARD, ARROWS INDICATE NUMBER OF CIRCUITS, HASH MARKS INDICATE NUMBER OF CONDUCTORS. OR P1 INFORMATION AT ARROWS ARE CIRCUIT NUMBERS AND P1 -3,5,7 PANELBOARD. �� EQUIPMENT GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION OR BARE) �1 ISOLATED GROUNDING CONDUCTOR IN CONDUIT (GREEN INSULATION WITH YELLOW TRACER) ....----■ CONDUIT CONCEALED - - - CONDUIT IN /UNDER FLOOR /GROUND CONSTRUCTION - - - - EXPOSED CONDUIT ^ �/ FLEXIBLE CONDUIT -- - -. LOW VOLTAGE CABLE O CONDUIT TURNING DOWN ((((i i.2 $ e � .V 6 ll Q p ,1}1, 6 6 0) Ci] u ® -A-2, SINGLE POLE WALL SWITCH (NO LETTER DESIGNATION) SWITCH LETTER DESIGNATIONS AS FOLLOWS: 2 = TWO POLE WALL SWITCH 3 = THREE -WAY WALL SWITCH 4 = FOUR -WAY WALL SWITCH D = DIMMER TYPE SWITCH OS = OCCUPANCY SENSOR P = SPST PILOT LIGHT SWITCH K = KEYED LIGHT SWITCH M = MOTOR RATED SWITCH ,)))) CEILING MOUNTED OCCUPANCY SENSOR WITH POWER SUPPLY AND LOAD RELAY AS REQUIRED OR SPECIFIED. SIMPLEX RECEPTACLE --- NEMA 5 -20R, LINO DUPLEX RECEPTACLE - NEMA 5 -20R, UNO DOUBLE DUPLEX RECEPTACLE - NEMA 5 -20R, LINO HEAVY DUTY RECEPTACLE - NEMA TYPE AS NOTED TWIST --LOCK TYPE RECEPTACLE RECEPTACLE INSTALLED 6" ABOVE COUNTER OR BACKSPLASH CEILING MOUNTED DUPLEX RECEPTACLE FLOOR MOUNTED DUPLEX RECEPTACLE ISOLATED GROUND (DUPLEX RECEPTACLE, SIMILAR FOR OTHERS) RECEPTACLE INSTALLED VIA DROP CORD GFCI RECEPTACLE LETTER DESIGNATIONS AS FOLLOWS: C = CLOCK HANGER TYPE E = EMERGENCY POWER S = SWITCHED IG = ISOLATED GROUND GFCI = GROUND FAULT CIRCUIT INTERRUPTER TR = TAMPER RESISTANT WP = WEATHERPROOF MULTI - OUTLET SURFACE RACEWAY WITH NEMA 5 -20R 40W 2 --LAMP T4 METAL HALIDE SEMI-RECESSED, ADJUSTABLE FIXTURE. PANELBOARD (SEE SCHEDULES) B2A AMERLUX MSRA- 39- T4 -E -WT- 120 - NF-SUN -FLO MULTI - SECTION PANELBOARD (SEE SCHEDULES) TTX# TRANSFORMER J iTX# SHIELDED RATINGS TRANSFORMER LJ AS SHOWN i i [ ~J TYPE AND RATINGS AS SHOWN 1 800A SWITCH 1 225A CIRCUIT BREAKER 3P RATING AS SHOWN ( RATINGS AS SHOWN I 200AS FUSED SWITCH 3P RATING,POLES AND 200AF FUSE TYPE AS SHOWN FRS ® CIRCUIT IDENTIFICATION - SEE CIRCUIT SCHEDULE GFR GROUND FAULT RELAY SD CONDUIT TURNING UP ® SHUNT TRIP rm.( 1 0 UTILITY METER (AS REQUIRED BY UTILITY) CURRENT TRANSFORMER RATING AS SPECIFIED OR REQUIRED CONNECTION POINT OR EQUIPMENT TERMINATION TERMINATION • EQUIPMENT 39W T6 METAL HALIDE TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR 44W LIGHTING 1 11' GROUND CONNECTION 0-111 GROUND ROD = CONTACT (OPEN OR CLOSED) A HEATER � MOTOR A 120V o FLUORESCENT LIGHT FIXTURE: (SEE LIGHT FIXTURE SCHEDULE) 1 PA a a = SWITCHED BY SWITCH "a" A = UGHT FIXTURE TYPE "A" p 120V/12V CI PENDANT FIXTURE WITH FLAT GLASS RING. FIXTURE INCLUDES 4" MONOPOINT CANOPY AND 75W LV TRANSFORMER. 1,2 PS ## BLOCK LOAD KW OR KVA 120 ar= SURFACE MOUNT FIXTURES FOR EXTERIOR SIGNAGE ILLUMINATION, CLEAR LENS, HONEYCOMB BAFFLE, 24" FROM WALL. 1 w ■ FLUORESCENT LICHT FIXTURE WITH NIGHT LIGHT RECEPTACLES 12" ON CENTER, LINO. TELEPHONE OUTLET - FLOOR OR WALL MOUNTED. INSTALL ® V AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. ,� Q DATA OUTLET - FLOOR OR WALL MOUNTED. INSTALL AT SAME ELEVATION AS ADJACENT RECEPTACLE, UNO. MULTI - SERVICE OUTLET - FLOOR OR WALL MOUNTED. INSTALL Ell V AT SAME ELEVATION AS ADJACENT RECEPTACLE, LINO. A MULTI- SERVICE POWER POLE WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS A MULTI - SERVICE FLOOR BOX WITH TELEPHONE, DATA AND POWER OUTLETS A = TYPE, SEE SCHEDULE IN SPECIFICATIONS ©A POKE THROUGH, A = TYPE, SEE SCHEDULE IN SPECIFICATIONS 0 THERMOSTAT JUNCTION BOX /OUTLET BOX J JUNCTION BOX /OUTLET BOX IM1 EMERGENCY SHUNT RELAY SIGNALING 58W 2 -LAMP LINEAR WIDE CHANNEL LIGHT FIXTURE WITH PLASTIC TUBE GUARD FOR LAMPS. 1 XC B T • SIGNALING BELL SIGNALING BUZZER LV TRANSFORMER 120V MR �- FLUORESCENT LIGHT FIXTURE WITH EMERGENCY LIGHTING BATTERY PACK FLUORESCENT LIGHT FIXTURE WITH DUAL BALLASTS CIRCUITED XW OR SEPARATELY. (SHADING IMPLIES EMERGENCY BALLAST WITH ( BATTERY PACK) A V V v_ ABBREVIATIONS A AMPERES, AIR (COMPRESSED) A/C AIR CONDITIONING AF AMPERE FUSE AFC ABOVE FINISHED CEILING AFC! ARC FAULT CIRCUIT INTERRUPTER AFEA AREA FOR EVACUATION ASSISTANCE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE Al ANALOG INPUT AIC AMPERE INTERRUPTING CURRENT AL ALUMINUM AO ANALOG OUTPUT AP ACCESS PANEL ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WIRE GAUGE BAS BUILDING AUTOMATION SYSTEM BFF BELOW FINISHED FLOOR BEG BELOW FINISHED GRADE BI BINARY INPUT BKR BREAKER BO BINARY OUTPUT C CONDUIT CD CANDELA CT CURRENT TRANSFORMER CATV CABLE TELEVISION SYSTEM CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CPT CONTROL POWER TRANSFORMER CU COPPER, CONDENSING UNIT CVD CUMULATIVE VOLTAGE DROP DDC DIRECT DIGITAL CONTROL DI DIGITAL INPUT, DUCTILE IRON DN DOWN DPDT DOUBLE -POLE, DOUBLE -THROW DPST DOUBLE -POLE, SINGLE -THROW EM EMERGENCY EPO EMERGENCY POWER OFF ETR EXISTING TO REMAIN FACP FIRE ALARM CONTROL PANEL FBO FURNISHED BY OTHERS OWNER / FCA FAULT CURRENT AMPS FF FINISHED FLOOR FLA FULL LOAD AMPS FLR FLOOR FVNR FULL - VOLTAGE, NON-REVERSING GC GENERAL CONTRACTOR GFCI GROUND FAULT CIRCUIT INTERRUPTER GER GROUND FAULT RELAY G GROUND GND GROUND GRS GALVANIZED RIGID STEEL HOA HAND -OFF -- AUTOMATIC IG ISOLATED GROUND ISC SHORT CIRCUIT CURRENT JB JUNCTION BOX J -BOX JUNCTION BOX kcmil 1000 CIRCULAR MILS KK KIRK KEY kV KILOVOLT kVA KILOVOLT -AMPS kVAR KILOVOLT -AMPS REACTIVE kW KILOWATT kWH KILOWATT -HOUR LF LINEAR FEET MAN MASTER ANTENNA TELEVISION SYSTEM MAX MAXIMUM MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MD MOTORIZED DAMPER MDP MAIN DISTRIBUTION PANEL MFR MANUFACTURER MG MOTOR GENERATOR MH MANHOLE MIN MINIMUM MLO MAW LUGS ONLY MOCP MAXIMUM OVERCURRENT PROTECTION MSB MAIN SWITCHBOARD MSWB MAIN SWITCHBOARD MS/TP MASTER SLAVE /TOKEN PASSING - COMMUNICATION TRUNK MTD MOUNTED N/A NOT APPLICABLE N/C NORMALLY CLOSED NIC NOT IN CONTRACT NL NIGHT LIGHT N/O NORMALLY OPEN QC ON CENTER OS OCCUPANCY SENSOR PDU POWER DISTRIBUTION UNIT PH, 0 PHASE PIV POST INDICATOR VALVE PNL PANEL PNLBD PANELBOARD PROVIDE FURNISH AND INSTALL PT POTENTIAL TRANSFORMER PTZ PAN, TILT, ZOOM QTY QUANTITY RCPT RECEPTACLE RLA RUNNING LOAD AMPS RTU ROOFTOP UNIT SD SMOKE DETECTOR, SUPPLY DUCT SF SQUARE FEET, SUPPLY FAN SPDT SINGLE -POLE, DOUBLE -THROW SPST SINGLE -POLE, SINGLE -THROW SS STAINLESS STEEL, SANITARY SEWER, SOIL STACK ST SHUNT TRIP, STEAM TRAP SWBD SWITCHBOARD Ti_ TWISTLOCK TR TAMPER RESISTANT TX TRANSFORMER TYP TYPICAL U/F UNDERFLOOR U/G UNDERGROUND UH UNIT HEATER U/5 UNDERSLAB UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY v VOLT(S) VAC VOLTS ALTERNATING CURRENT VD VOLTAGE DROP VDC VOLTS DIRECT CURRENT VFD VARIABLE FREQUENCY DRIVE W WIRE WP WEATHERPROOF XP EXPLOSION -PROOF LIGHTING TRACK WITH LIGHT FIXTURE TYPES AS INDICATED 0A LIGHT FIXTURE - CEILING / WALL MOUNTED. y A = LIGHT FIXTURE TYPE "A" A WALL WASHER LIGHT FIXTURE - ARROW INDICATES DIRECTION. ®1 A = LIGHT FIXTURE TYPE "A" A WALL MOUNTED LIGHT FIXTURE. A = UGHT FIXTURE TYPE "A" (� `l' ❑ SITE LIGHTING FIXTURE (SEE LICHT FIXTURE SCHEDULE) o a A EXIT SIGN - CEILING / WALL MOUNTED, ARROWS AS INDICATED. ® A = UGHT FIXTURE TYPE "A" (SEE LIGHT FIXTURE SCHEDULE) �4A EMERGENCY BATTERY PACK LIGHT FIXTURE - CEILING /WALL MOUNTED. (SEE LIGHT FIXTURE SCHEDULE) POWER EQUIPMENT & DEVICES ELECTRICAL SERVICE PANELBOARD ■ 1Eir (SURFACE OR FLUSH MOUNT) o = TERMINAL CABINET (SURFACE OR FLUSH MOUNT), TYPE AS NOTED PLYWOOD TERMINAL BOARD FOR TELEPHONE STANDARD MOUNTING HEIGHTS (AFF, AFG, UNLESS NOTED OTHERWISE) ELECTRICAL ALARMS 48" ANNUNCIATOR PANELS 48" CLOCK OUTLETS (CENTERLINE) 84" CONTROLS (CENTERLINE) 48" EXIT SIGNS (WALL MOUNTED, BOTTOM) 80" INTERCOM (AFEA ONLY) 36 " INTERCOMS 48" PANELS /PANELBOARDS (TOP) 72 " PHOTOCELLS 144" RECEPTACLES (CENTERLINE) 18" RECEPTACLES (EXTERIOR) 24" RECEPTACLES (GARAGES) 26" RECEPTACLES IN EQUIPMENT ROOMS 48" REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) 48" REMOTE INDICATING LIGHT (FINISHED AREAS) CEILING SAFETY SWITCHES 48" STARTERS 48" SWITCHES (CENTERLINE) 48" " 36" TELEPHONES (PUBLIC) 1 © 48 , 1 © 36 TELEPHONE, DATA OUTLETS (CENTERLINE) 18" TELEPHONE TERMINAL BOARD (BOTTOM) 6" TELEVISION OUTLETS 18" .. SYSTEM, UNO. SIZE AS NOTED. r / /1, ELECTRICAL DISTRIBUTION PANELBOARD LIGHTALARMS ELF605P r lA SWITCHBOARD OR MOTOR CONTROL CENTER ON HOUSEKEEPING PAD 20W RECESSED GIMBALL EMERGENCY LIGHT, PLASTIC TRIM RING. PROVIDE 90 MINUTE BATTERY BACK -UP. PROVIDE 20W LAMPS IN LIEU OF 8W LAMPS SUPPLIED WITH FIXTURES TO MEET EMERGENCY LIGHTING PHOTOMETRICS. 1 TRANSFORMER -431" MOTOR 200/3/150 DISCONNECT SWITCH - "200/3/150" DENOTES q= AMPERES /POLE /FUSE NF= NON -FUSED CB= CIRCUIT BREAKER (200/3/CB) COMBINATION DISCONNECT SAFETY SWITCH AND (SAFETY) 30/3/15/1 MOTOR STARTER "30/3/15/1" DENOTES L® AMPERES /POLE /FUSE /NEMA STARTER SIZE NF= NON -FUSED CB= CIRCUIT BREAKER (30/3/CB/1) MAGNETIC MOTOR STARTER, NEMA licioi 2 SIZE AS NOTED. 3 -POLE, UNO. MS MANUAL STARTER 120V/277V VFD VARIABLE FREQUENCY DRIVE ® RELAY OR CONTACTOR (IN SCHEMATICS) MAGNETIC CONTACTOR, SIZE, COIL VOLTAGE AND C L NUMBER OF POLES AS INDICATED (L= LIGHTING CONTACTOR, P= POWER CONTACTOR) TS TIME SWITCH PC PHOTOCELL g INDICATING LIGHT • PUSH BUTTON ANNOTATION WC 1 ® ELECTRICAL PLAN NOTE CALLOUT TECHNOLOGY PLAN CALLOUT 120V 1 EQUIPMENT DESIGNATION (OWNER FURNISHED, CONTRACTOR INSTALLED) CONNECTION POINT OF NEW WORK TO EXISTING Q DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER • • STOP -START PUSH BUTTON CONTROL STATION NUTONE 769RL ••• HAND- OFF -AUTO PUSH BUTTON CONTROL STATION NW LOWER NUMBER INDICATES SHEET NUMBER Q 0 "D MUSHROOM -TYPE PUSH BUTTON IV OVERHEAD PADDLE FAN SECTION CUT DESIGNATION LIGHT FIXTURE SCHEDULE TYPE -MANUFACTURER /MODEL 1 LAMP VOLTAGE WATTS (VA) DESCRIPTION NOTES B2 AMERLUX MSRA- 2- 20- T4 -E -B- 120 -FL -W (2) 20W T4 METAL HALIDE 120V 40W 2 --LAMP T4 METAL HALIDE SEMI-RECESSED, ADJUSTABLE FIXTURE. 1 B2A AMERLUX MSRA- 39- T4 -E -WT- 120 - NF-SUN -FLO (1) 39W T4 METAL HALIDE 120V 44W SINGLE LAMP T4 METAL HALIDE SEMI- RECESSED ADJUSTABLE FIXTURE. 1 SD AMERLUX SD6- 39- T6- E -SD -W- 120 -FL -SUN 39W T6 METAL HALIDE 120V 44W 6" SQUARE LENSED DOWNLIGHT WITH T6 METAL HALIDE LAMP. 6' ADJUSTABLE SQUARE LENSED DOWNLIGHT WITH T6 METAL HALIDE LAMP. 1 1 SA AMERLUX SA6- 39- T6- E -SD -W- 120 -FL -SUN 39W T6 METAL HALIDE 120V 44W RA AMERLUX RA6- 39- T6- E -SD -W- 120 -FL -SUN 39W T6 METAL HALIDE 120V 44W 6" ROUND ADJUSTABLE LENSED DOWNLIGHT WITH T6 METAL HALIDE LAMP. 1 PA BRUCK 220097MC/MP -76" 35W MR16 FLOOD 120V/12V 35W PENDANT FIXTURE WITH FLAT GLASS RING. FIXTURE INCLUDES 4" MONOPOINT CANOPY AND 75W LV TRANSFORMER. 1,2 PS BK LIGHTING INC. ST- 4- BLP- 13- 11- B -24 -C (2) 50W MR16 120 100W SURFACE MOUNT FIXTURES FOR EXTERIOR SIGNAGE ILLUMINATION, CLEAR LENS, HONEYCOMB BAFFLE, 24" FROM WALL. 1 SR MERCURY MM- 232- OCT- C- ELB -UNI R & R PLASTIC TUBE GUARD - PAL40T8 F32T8/TL835 120V 58W 2 -LAMP LINEAR WIDE CHANNEL LIGHT FIXTURE WITH PLASTIC TUBE GUARD FOR LAMPS. 1 XC COOPER - ATLITE TSC16RWSA INCLUDED 120V 5W EDGELIT EXIT SIGN 1 XW LIGHTALARMS U- XQELR -DC INCLUDED 120V 5W LED EXIT SIGN 1 BP LIGHTALARMS 2P12Q1/L25 -M INCLUDED 120/277 12W 12V EMERGENCY LIGHTING FIXTURE WITH 25W HEADS AND 90 MINUTE BATTERY BACK -UP 1 CEH LIGHTALARMS ELF605P INCLUDED 120V 20W RECESSED GIMBALL EMERGENCY LIGHT, PLASTIC TRIM RING. PROVIDE 90 MINUTE BATTERY BACK -UP. PROVIDE 20W LAMPS IN LIEU OF 8W LAMPS SUPPLIED WITH FIXTURES TO MEET EMERGENCY LIGHTING PHOTOMETRICS. 1 WMEH HIGHLITES HL -90 INCLUDED 120V/277V 10W EMERGENCY LIGHTING UNIT WITH (2) 5.4W HEADS AND 90MIN BATTERY BACK -UP, CEILING - MOUNTED WHERE APPLICABLE. 1 WC LITHONIA WC- 2- 25- MVOLT- GEB10IS F25T8/TL835 120V 46W 3 -0" ALL PURPOSE WALL BRACKET CHANNEL WITH (2) 25W T8 LAMPS. 1 FC NUTONE 769RL 60W A19 120V 240W TOILET ROOM FAN /LIGHT COMBO. FIXTURE TO BE LABELED FROM FACTORY TO ACCEPT ONLY 60W LAMPS. 1 NOTES: 1. ALL LIGHT FIXTURES FURNISHED BY GODIVA VIA CAPITAL LIGHTING 2. BOTTOM OF PENDANT TO BE AT 6' -8" AFF. 3. NOT ALL FIXTURES SHOWN ON THIS SCHEDULE ARE PROVIDED ON EACH GODIVA STORE. REVISIONS_ ' No changes shat de to the scone of work without prior approval of Tukwila Building Division , I NOTE: Revisions will require a new plan submittal and may include additional plan revin"' fees ELECTRICAL GENERAL NOTES: 1. FIELD VERIFY ALL CONDITIONS. SEPARATE D PERMIT REQUIRED ❑ E1ectrical plumbing t 'Gas Piping I City of Tukwila ',BUILDING DIVISION 2. DESIGN DRAWINGS ARE SCHEMATIC. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. 3. CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN. INCLUDE IN BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT AND /OR ENGINEER VIA OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT AND /OR ENGINEER VIA THE OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. 5. MINOR VARIATIONS DUE TO UNFORSEEN CONDITIONS THAT MAY EFFECT THE CONTRACTOR'S SCOPE OF WORK, REQUIRED FOR ACCOMPLISHING THE INTENT OF THIS DESIGN SHALL BE INCLUDED IN CONTRACTOR'S PRICING. 6. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL REQUIRED PERMITS. CONTRACTOR'S INSTALLATION SHALL CONFORM TO ALL LOCAL CODE REQUIREMENTS. 7. VERIFY EXACT PLACEMENT OF ALL DEVICES SHOWN OF THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. 8. BECOME FAMIUAR WITH REQUIRED DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL DEMOLITION AS REQUIRED FOR INSTALLATION OF NEW WORK. 9. COORDINATE INSTALLATION OF ELECTRICAL WORK ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF PLUMBING AND MECHANICAL INSTALLATION. CONDUFT RUNS TO BE RUN THROUGH TRUSSES WHERE POSSIBLE. 10. COORDINATE EXACT LOCATION OF DEVICES SERVING CASEWORK WITH CASEWORK CONTRACTOR. 11. COORDINATE ALL LOW VOLTAGE CONDUIT AND ROUGH -IN REQUIREMENTS WITH LOW VOLTAGE CONTRACTORS. 12. SWITCHBOARDS, PANELBOARD, DISCONNECT SWITCHES, TRANSFORMER AND CONTACTORS SHALL BE LISTED AND IDENTIFIED AS RATED FOR A MINIMUM OF 75'C CONDUCTOR TERMINATIONS. 13. INCLUDE EQUIPMENT GROUND CONDUCTOR IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH NEC. 14. PROVIDE ALL EMPTY CONDUITS WITH A PULL STRING. 15. PROVIDE #10 AWG CONDUCTORS FOR ALL 20A BRANCH CIRCUITS BETWEEN 100' AND 150' IN LENGTH. PROVIDE #8 AWG CONDUCTORS FOR ALL 20A BRANCH CIRCUITS OVER 150'. 16. PROVIDE #12 AWG CONDUCTORS, #12G, IN 3/4" CONDUIT FOR ALL 20A BRANCH CIRCUITS UNLESS NOTED OTHERWISE. 17. CIRCUITING INDICATED ON PLAN 15 PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU- WIRING" WHERE /WHEN POSSIBLE. MULTI - CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR FIELD CONDITIONS OR VOLTAGE DROP FACTORS MAY BE REQUIRED (FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU- WIRING "), AND RELATED COSTS SHALL BE INCLUDED IN BID. 18. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF UGHT FIXTURES. FILE COPY Permit No. Plar review approval is Subjec t to errs and ardesions. Approvaleconstructiondoomentsdoesnotadhonze VieviolatIondanyikkOedoodecradhance.Flece#4 of approved Re fd Copy and cones is acknowledged: QY- (7 -o6 By, Date: City of Tukwila BUILDING DIVISION 19. EMERGENCY LIGHTS SHALL BE INSTALLED AND CIRCUITED PER NEC AND ALL LOCAL CODES. ALL EMERGENCY FIXTURES SHALL BE DUAL VOLTAGE (120/277 AUTO XFMR) BATTERY BACK -UP UNITS. INSTALL CENTRAL BATTERY BACK -UP ONLY IF INDIVIDUAL UNITS ARE PROHIBITED BY LOCAL CODES. CLOSELY COORDINATE WITH TENANT CONSTRUCTION MANAGER. 20. MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. 21. WHERE DRYWALL CEILINGS ARE USED, ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITING SO THAT JUNCTION BOXES /ACCESS PANELS ARE NOT REQUIRED IN THESE DRYWALL CEILING AREAS. (THE USE OF JUNCTION BOXES IN THESE DRYWALL CEILINGS IS NOT PERMITTED, ARRANGE CIRCUITS TO AVOID THIS SITUATION). FIELD COORDINATE WITH TENANT'S CONSTRUCTION MANAGER PRIOR TO ROUGH-IN TO AVOID CONFLICTS. JUNCTION BOXES MAY BE PLACED ABOVE LAY -IN CEILINGS. 22. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 23. PLACEMENT OF ALL RECEPTACLES SHALL BE INTENTIONAL (I.E. CENTERED ON COLUMNS OR WALL FEATURES OR TIGHT TO CORNER). IF RECEPTACLE I5 NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUCTION MANAGER PRIOR TO RECEPTACLE BOX ROUGH -IN. 24. INSTALLATION OF LIGHTING FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. 25. ALL LIGHT FIXTURES SCHEDULED MAY NOT NECESSARILY BE USED ON THIS PROJECT. REFER TO ELECTRICAL LIGHTING PLAN. 26. PROVIDE ALL NECESSARY COMPONENTS TO MAKE A COMPLETE WORKING SYSTEM. VERIFY ROW LENGTHS, FEED POINT AND MOUNTING REQUIREMENTS PRIOR TO ORDERING. 27. TAKE ADEQUATE CARE TO CORRECTLY LOCATE ALL ELECTRICAL STUBOUTS, FLOOR BOXES, JUNCTION BOXES, TRACK, ETC. PRECISE LOCATIONS OF FLOOR OUTLETS AND JUNCTION BOXES I5 VERY IMPORTANT. 28. ALL CAT -5e WIRE TO BE PROVIDED BY OWNER'S VENDOR. ELoB 128 Puhrte Works, Building Division PERMIT NUMBER 08 Approw,; 8 Date3A0r TAG RECEIVED EWER FEB D - 8 2008 PERMIT CENTER HENDERSON ENGINEERSI 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7701 FAX 713 783 7797 www.hei- eng.com 0750001294 R1S 1MH SLM 4325 Tam -O- Shanter Way, Dayton, OH 454291 p 937.477.23341 info @mada4.com EXP. 12/08/08 0 v qb Fo *E1 co cD 0 O to 4 ate'' LO Lu LO o 0 O INT 0 0- 0) MODA4 PROJECT NUMBER: 07009 ISSUED /REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 SCHEDULES AND LEGENDS E -1.0 FILE COSY 1 2 3 4 5 6 7 8 9 10 REMOTE STOCK ROOM ELECTRICAL LIGHTING PLAN SCALE: 1/4" =1' -0" SALES AREA ACCENT LTG DIPPING UNIT /STOREFRONT LTG CORE CABINETS SALES AREA DOWN LTG SLAB SHELVES (a) (b) (a) (d) (e) 0 0 0 0 0 0 L -9 0 0 0 0 L -3 L -16 L -7 L -15 O BAR DISPLAY LTG CUSTOM AND CORE LIGHTS BACK BAR LIGHTS NESTING TABLE LTG (f) (g) (h) (i) O 0 0 0 O 0 0 0 L -1 L -15 L -5 L -7 SWITCH BANK DETAIL NOT TO SCALE n T BULK CASE /REGISTER LTG NESTING TABLE LTG CORE CABINETS STOREFRONT LIGHTBOXES 0) (k) (1) (m) O 0 0 0 O 0 0 0 L -12 L -16 L -16 L -6 � ,� , t� =� -gin= — �r �l -JJ °i , i 2 8 � i iJ ; l� 1 � � - 10 ?i MN - REMOTE STOCK ROOM ■ 102 ® EX STING PNLBD REMOTE STOCK ROOM ELECTRICAL LIGHTING PLAN SCALE: 1/4" =1' -0" SALES AREA ACCENT LTG DIPPING UNIT /STOREFRONT LTG CORE CABINETS SALES AREA DOWN LTG SLAB SHELVES (a) (b) (a) (d) (e) 0 0 0 0 0 0 L -9 0 0 0 0 L -3 L -16 L -7 L -15 O BAR DISPLAY LTG CUSTOM AND CORE LIGHTS BACK BAR LIGHTS NESTING TABLE LTG (f) (g) (h) (i) O 0 0 0 O 0 0 0 L -1 L -15 L -5 L -7 SWITCH BANK DETAIL NOT TO SCALE n T BULK CASE /REGISTER LTG NESTING TABLE LTG CORE CABINETS STOREFRONT LIGHTBOXES 0) (k) (1) (m) O 0 0 0 O 0 0 0 L -12 L -16 L -16 L -6 � ,� , t� =� -gin= — �r �l -JJ , i 2 8 � i iJ ; l� SALES AREA 101 TO SWITCH "k" TO SWITCH "a" REVIEWED FOR CODE COMPUANCE NFPA70 -NEC MAR 2 6 2008 BY Of Tukwila LDt . G DM IIN. NOTE: 2006 IBC -- Sec. 1006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. TO SWITCH "e" 11 (PART) TO SWITCH "m" L ALL EXISTING EXTERIOR EGRESS LIGHTING IS BY LANDLORD. ELECTRICAL LIGHTING PLAN SCALE: 1/4 " =1' -0" 4 ELECTRICAL PLAN NOTES: El MASTER SWITCH BANK. REFER TO DETAIL 3 ON THIS SHEET FOR MORE INFORMATION. LIGHT FIXTURES INSTALLED IN ISLAND BY FIXTURE CONTRACTOR AND CONNECTED TO JUNCTION BOX IN FIXTURE. ROUTE CONDUIT UNDERGROUND FROM ISLAND TO WALL AS SHOWN. GROUP CONDUIT WITH OTHER UNDERGROUND CONDUITS SHOWN ON SHEET E -2.1. RECEPTACLES FOR SLAB SHELVE LIGHT FIXTURES. INSTALL LIGHT FIXTURES FOR SHELVES SUPPLIED WITH SLAB SHELVES AND MAKE FINAL CONNECTIONS. SWITCH SHELVES AND SIGNS SEPARATELY. COORDINATE RECEPTACLES WITH FIXTURE DRAWINGS. El 6 0 CONNECTION POINT FOR LIGHT FIXTURE INSTALLED IN CORE CABINET BY FIXTURE CONTRACTOR. COORDINATE ELECTRICAL CONNECTION WITH FIXTURE DRAWINGS. CIRCUIT EMERGENCY LIGHTING FIXTURES AHEAD OF ANY SWITCHING. INTERNALLY ILLUMINATED SIGN BOX FURNISHED BY TENANT. CIRCUIT VIA TIMESWITCH. SET TIMESWITCH TO MALL'S OPERATING HOURS. LIGHT FIXTURES INSTALLED IN STOREFRONT DIPPER BY FIXTURE CONTRACTOR. MAKE ALL ELECTRICAL CONNECTIONS AS REQUIRED. CUT FLOOR TO FIXTURE AND PROVIDE (2) DUPLEX OUTLETS IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWTICHED CIRCUIT L -7 AND LABEL RECEPTACLE "LIGHTING." CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E -2.1. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. l a l - SHOW WINDOW RECEPTACLE. COLOR OF RECEPTACLE AND COVER PLATE SHALL MATCH CEILING COLOR. El 10 m 12 NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEILING. REFER TO DETAIL 3, SHEET E -2.1 FOR FURTHER INFORMATION. EXISTING REMOTE STORAGE ROOM. NO ELECTRICAL WORK TO BE PERFORMED TO EXISTING SPACE. LOCATION OF CONTACTORS "C1 " AND "C2 ", AND TIMESWITCH "TS1 ". REFER TO SHEET E -4.0 FOR CONTACTOR SCHEDULE. LIGHT FIXTURE LOCATED ABOVE FINISHED RESTROOM, FOR STORAGE ILLUMINATION. RENNF. FEB -8 2008 PERMIT CENTE HENDERSON ENGINEERS=_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.com 0750001294 R1S JMH SLM 4325 Tani-O-Shanter Way, Dayton, OH 454291 p 937.4772334 f Info @moda4.com EXP.12 /08/03 Q D 0 555 Southcenter N EL O U MODA4 PROJECT NUMBER: 07009 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 ELECTRICAL LIGHTING PLAN E -2.0 1 2 4 5 6 7 8 10 FIRE PROTECT. SYMBOLS NOTE: THIS NECESSARILY IS A MASTER USED LEGEND DN THE AND NOT RAWINGS. ALL SYMBOLS, ETC. ARE D FIRE ALARM F© FIRE ALARM CONTROL PANEL /UNIT J FACP RECESSED FIRE ALARM CONTROL PANEL /UNIT FAAP FIRE ALARM ANNUNCIATOR PANEL FAAP RECESSED FIRE ALARM ANNUNCIATOR PANEL I=1 FACT FIRE ALARM TRANSPONDER ■ AMP AMPLIFIER PANEL RPS REMOTE POWER SUPPLY RT REMOTE TEST STATION WITH INDICATING LIGHT RL REMOTE INDICATING LIGHT PS PRESSURE SWITCH LOW /HIGH FS WATERFLOW ALARM SWITCH © CONTROL VALVE TAMPER SWITCH DH MAGNETIC DOOR HOLD OPEN DEVICE K KNOX BOX PULL STATION VI FIREFIGHTER'S PHONE JACK a HEAT DLILCTOR (E INDICATES ELEVATOR RECALL) SMOKE DETECTOR (E INDICATES ELEVATOR RECALL) SINGLE STATION SMOKE DETECTOR ? ')))))) BEAM DETECTOR DUCT MOUNTED SMOKE DETECTOR SUPPLY Q RD 0 Di I RI ❑) 0 (SD= /RD= RETURN) AREA OF REFUGE 2 -WAY COMMUNICATION SYSTEM WALL MOUNTED AUDIBLE NOTIFICATION APPLIANCE WALL MOUNTED VISIBLE NOTIFICATION APPLIANCE ## ## INDICATES CANDELA II WALL MOUNTED AUDIBLE /VISIBLE NOTIFICATION APPLIANCE, ## ## INDICATES CANDELA MOUNTED AUDIBLE NOTIFICATION APPLIANCE CEILING MOUNTED VISIBLE NOTIFICATION APPLIANCE, ## ## INDICATES CANDELA CEILING MOUNTED AUDIBLE /VISIBLE NOTIFICATION APPUANCE, ## ## INDICATES CANDELA ABORT SWTICH BELL ANNOTATION O FIRE PROTECTION PLAN CALLOUT s CONNECTION POINT OF NEW WORK TO EXISTING Q DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER ilIZIF LOWER NUMBER INDICATES SHEET NUMBER Aft my SECTION CUT DESIGNATION ABBREVIATIONS AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE CD CANDELA DI DUCTILE IRON ESFR EARLY SUPPRESSION FAST RESPONSE ETTR EXISTING TO REMAIN FHC FIRE HOSE CABINET FP FIRE PROTECTION GC GENERAL CONTRACTOR GPM GALLONS PER MINUTE JB JUNCTION BOX MAX MAXIMUM MIN MINIMUM N/A NOT APPLICABLE NIC NOT IN CONTRACT OC ON CENTER PIV POST INDICATOR VALVE PROVIDE FURNISH AND INSTALL PRV PRESSURE REDUCING VALVE RD RETURN DUCT REV REVISION SD SUPPLY DUCT SF SQUARE FEET TYP TYPICAL UL UNDERWRITERS LABORATORIES, INC. UNO UNLESS NOTED OTHERWISE V VOLT(S) WP WEATHERPROOF 0� REMOTE STOCK ROOM 104 m iii‘EXISTING PNLBD m REMOTE STOCK ROOM ELECTRICAL POWER PLAN SCALE: 1 /4 " =1' -0" 31 30/2/15/3R 30/3/20/3R L 29 7 SUPPORT SYSTEM SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER INSTALL TRANSFORMER ABOVE AND IN FRONT OF ELECTRICAL PANELBOARD MINIMUM DISTANCE 1' -0" PANELBOARD WORKING SPACE CLEARANCE AS REQUIRED BY NEC SALES AREA 101 7 DEDICATED ELECTRICAL SPACE. EXTENDS TO 6' ABOVE PANEL BOARD OR TO STRUCTURAL CEILING, WHICHEVER 15 LOWER. LOCATE TRANSFORMER 6" MINIMUM FROM ALL WALLS. MAXIMUM OF 10' SECONDARY CONDUCTOR LENGTH. FLEXIBLE CONDUIT RIGID CONDUIT ELECTRICAL PANELBOARD SUPPLIED BY TRANSFORMER DEDICATED ELECTRICAL SPACE (BOTTOM OF PANELBOARD TO FLOOR) SUSPENDED TRANSFORMER MOUNTING LOCATION NOT TO SCALE ELECTRICAL POWER PLAN SCALE: 1/4"=1'-0" FIRE ALARM GENERAL NOTES: 1. FIRE ALARM SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL BE IN ACCORDANCE WITH NFPA 70 AND NFPA 72. SYSTEM SHALL ALSO MEET ALL APPLICABLE BUILDING CODES, FIRE CODES AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER. VERIFY REQUIREMENTS PRIOR TO BID SUBMITTAL. 2. INFORMATION ON CONTRACT DOCUMENTS I5 GENERAL INFORMATION AND FOR BID PURPOSES ONLY. LAYOUT SYSTEM, PERFORM REQUIRED CALCULATIONS AND COORDINATE WITH OTHER TRADES. 3. PROVIDE ADDITIONAL MATERIALS AND LABOR REQUIRED DUE TO LACK OF COORDINATION OR TO MEET AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. 4. PROVIDE ALL EQUIPMENT AND LABOR REQUIRED FOR A COMPLETE AND OPERATIONAL FIRE ALARM SYSTEM. 5. THE FIRE ALARM CONTROL PANEL (FACP) SHOWN SHALL BE COORDINATED WITH THE FIRE DEPARTMENT AND AHJ PRIOR TO INSTALLATION. 6. PROVIDE AUDIBLE AND VISIBLE NOTIFICATION APPLIANCES AS INDICATED ON THE DRAWINGS. 7. PROVIDE DUCT DETECTION AND SHUTDOWN FOR AIR DISTRIBUTION SYSTEMS EXCEEDING 2000 CFM. DUCT SMOKE DETECTION SHALL TRANSMIT A SUPERVISORY SIGNAL TO THE FACP. 8. FORWARD COMPLETED FIRE ALARM CERTIFICATE OF COMPLETION TO THE OWNER. 9. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. FIRE ALARM PLAN NOTES: 10 PROVIDE DUCT MOUNTED SMOKE DETECTOR FOR AIR HANDLING UNIT SHUT -DOWN. INSTALL DETECTOR PER MANUFACTURER'S RECOMMENDATIONS. REFER TO MECHANICAL SHEETS FOR AIR HANDLING UNIT AND DUCTWORK LAYOUT AND DETAILS. O PROVIDE LOW VOLTAGE WIRING FROM DUCT DETECTOR TO REMOTE TEST STATION. MOUNT REMOTE TEST STATION AT 48" AFF. KD CONNECT FIRE SPRINKLER MONITORING DEVICES TO FIRE ALARM SYSTEM. COORDINATE QUANTITY AND LOCATION OF DEVICES WITH FIRE PROTECTION SYSTEMS. FLOOR ELECTRICAL GENERAL NOTES: MAKE ALL CONNECTIONS BETWEEN LOW - VOLTAGE DATA COMMUNICATTONS WIRING AND CASH REGISTER. 2. PROVIDE PULL THRU CONDUIT BETWEEN CASH REGISTER COUNTERS FOR CASH REGISTER INSTALLATION COMPANY. 3. VERIFY ALL NEW WORK REQUIRED BY THE LANDLORD. 4. ALL WORK OUTSIDE OF THE TENANT SPACE SHALL BE BY A LANDLORD APPROVED CONTRACTOR. 5. PROVIDE ACCESS TO ANY LANDLORD EQUIPMENT, VALVES, DAMPERS, CLEANOUTS, JUNCTION BOXES, ETC. LOCATED ABOVE GYPSUM BOARD CEILING AREAS. VERIFY WITH LANDLORD PRIOR TO START OF WORK. 6. ALL REQUIRED INTERIOR PHONE CONDUIT WITH PULL STRING SHALL BE SUPPUED BY THE GENERAL CONTRACTOR FROM CASH REGISTER TO DEMARK. 7. DO NOT ATTACH OR SUPPORT ANY ELECTRICAL CONDUITS FROM THE ROOF DECK. HANGERS, CLAMPS, AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. ELECTRICAL PLAN NOTES: TT 4 n 0 8 n 10 m CONNECTION FOR COOLED SHOWCASE. PROVIDE CIRCUITING AS SHOWN IN SLAB IN 3/4 "C. COORDINATE SAW GUTTING OF SLAB WITH ARCHITECT AND OWNER. RECEPTACLE AND DATA OUTLET FOR P05 STATION WITHIN MILLWORK. COORDINATE EXACT LOCATION WITH ARCHITECT/ OWNER PRIOR TO ROUGH -IN. COORDINATE LOCATION OF RECEPTACLES ALONG BACK COUNTER WITH FIXTURE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. RECEPTACLES FURNISHED BY FIXTURE SUPPLIER. CIRCUIT AS SHOWN. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. PROVIDE DUPLEX RECEPTACLE FOR MUSIC SYSTEM. VERIFY EXACT LOCATION WITH ARCHITECT /OWNER PRIOR TO ROUGH-IN. CUT FLOOR TO STOREFRONT DIPPER AND PROVIDE (2) DUPLEX RECEPTACLES IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWITCHED CIRCUIT AND LABEL RECEPTACLE "POWER ". CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E -2.0. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. PROVIDE (2) 1" CONDUITS WITH PULL WIRE UNDER SLAB AS SHOWN TO BACK WALL. ROUTE DATA CONDUITS OVERHEAD BACK TO STOCK ROOM. NEW " VENTROL" REFRIGERATION AND CONDENSING UNITS PROVIDED BY GODIVA. VENTROL CONDENSING UNIT LOCATED ON ROOF. LOCATION TO BE DETERMINED. COORDINATE FINAL LOCATION OF CONDENSING UNIT WITH LANLORD PRIOR TO INSTALLATION. NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEILING. REFER TO DETAIL 3, THIS SHEET, FOR FURTHER INFORMATION. EXISTING REMOTE STOCK ROOM. NO ELECTRICAL WORK TO BE PERFORMED TO EXISTING SPACE. PROVIDE EDWARDS SIGNALING AND SECURITY SYSTEM PULL CORD #6537 IN HANDICAPPED RESTROOM FOR STAND -ALONE CALL -FOR- AID SYSTEM. PROVIDE POWER THROUGH CIRCUIT L -27. PROVIDE EDWARDS SIGNALING AND SECURITY SYSTEM HORN/ STROBE #6536-G5 IN HANDICAPPED RESTROOM FOR STAND -ALONE CALL-FOR-AID SYSTEM. RECraVET FEB - 8 2008 PERMIT CENTEL HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hel- eeg.com 0750001294 RJS JMH SIM 4325 Tam -O- Shanter Way, Dayton, OH 454291 p 937.477.2334 j info ®moda4.com 12/18/ Q V 1 1 4 W 0 F. Z F-- Q W '- (i) 0 N O 0 0- MODA4 PROJECT NUMBER: 07009 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT 12.17.07 01.03.08 01.11.08 01.25.08 ELECTRICAL POWER PLAN E -2.1 I L) � I o co_ 11_x' o. SUPPORT SYSTEM SHALL BE DESIGNED BY A LICENSED STRUCTURAL ENGINEER INSTALL TRANSFORMER ABOVE AND IN FRONT OF ELECTRICAL PANELBOARD MINIMUM DISTANCE 1' -0" PANELBOARD WORKING SPACE CLEARANCE AS REQUIRED BY NEC SALES AREA 101 7 DEDICATED ELECTRICAL SPACE. EXTENDS TO 6' ABOVE PANEL BOARD OR TO STRUCTURAL CEILING, WHICHEVER 15 LOWER. LOCATE TRANSFORMER 6" MINIMUM FROM ALL WALLS. MAXIMUM OF 10' SECONDARY CONDUCTOR LENGTH. FLEXIBLE CONDUIT RIGID CONDUIT ELECTRICAL PANELBOARD SUPPLIED BY TRANSFORMER DEDICATED ELECTRICAL SPACE (BOTTOM OF PANELBOARD TO FLOOR) SUSPENDED TRANSFORMER MOUNTING LOCATION NOT TO SCALE ELECTRICAL POWER PLAN SCALE: 1/4"=1'-0" FIRE ALARM GENERAL NOTES: 1. FIRE ALARM SYSTEM DESIGN, INSTALLATION AND MATERIALS SHALL BE IN ACCORDANCE WITH NFPA 70 AND NFPA 72. SYSTEM SHALL ALSO MEET ALL APPLICABLE BUILDING CODES, FIRE CODES AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER. VERIFY REQUIREMENTS PRIOR TO BID SUBMITTAL. 2. INFORMATION ON CONTRACT DOCUMENTS I5 GENERAL INFORMATION AND FOR BID PURPOSES ONLY. LAYOUT SYSTEM, PERFORM REQUIRED CALCULATIONS AND COORDINATE WITH OTHER TRADES. 3. PROVIDE ADDITIONAL MATERIALS AND LABOR REQUIRED DUE TO LACK OF COORDINATION OR TO MEET AUTHORITY HAVING JURISDICTION AND INSURANCE CARRIER REQUIREMENTS AT NO ADDITIONAL COST TO THE OWNER. 4. PROVIDE ALL EQUIPMENT AND LABOR REQUIRED FOR A COMPLETE AND OPERATIONAL FIRE ALARM SYSTEM. 5. THE FIRE ALARM CONTROL PANEL (FACP) SHOWN SHALL BE COORDINATED WITH THE FIRE DEPARTMENT AND AHJ PRIOR TO INSTALLATION. 6. PROVIDE AUDIBLE AND VISIBLE NOTIFICATION APPLIANCES AS INDICATED ON THE DRAWINGS. 7. PROVIDE DUCT DETECTION AND SHUTDOWN FOR AIR DISTRIBUTION SYSTEMS EXCEEDING 2000 CFM. DUCT SMOKE DETECTION SHALL TRANSMIT A SUPERVISORY SIGNAL TO THE FACP. 8. FORWARD COMPLETED FIRE ALARM CERTIFICATE OF COMPLETION TO THE OWNER. 9. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. FIRE ALARM PLAN NOTES: 10 PROVIDE DUCT MOUNTED SMOKE DETECTOR FOR AIR HANDLING UNIT SHUT -DOWN. INSTALL DETECTOR PER MANUFACTURER'S RECOMMENDATIONS. REFER TO MECHANICAL SHEETS FOR AIR HANDLING UNIT AND DUCTWORK LAYOUT AND DETAILS. O PROVIDE LOW VOLTAGE WIRING FROM DUCT DETECTOR TO REMOTE TEST STATION. MOUNT REMOTE TEST STATION AT 48" AFF. KD CONNECT FIRE SPRINKLER MONITORING DEVICES TO FIRE ALARM SYSTEM. COORDINATE QUANTITY AND LOCATION OF DEVICES WITH FIRE PROTECTION SYSTEMS. FLOOR ELECTRICAL GENERAL NOTES: MAKE ALL CONNECTIONS BETWEEN LOW - VOLTAGE DATA COMMUNICATTONS WIRING AND CASH REGISTER. 2. PROVIDE PULL THRU CONDUIT BETWEEN CASH REGISTER COUNTERS FOR CASH REGISTER INSTALLATION COMPANY. 3. VERIFY ALL NEW WORK REQUIRED BY THE LANDLORD. 4. ALL WORK OUTSIDE OF THE TENANT SPACE SHALL BE BY A LANDLORD APPROVED CONTRACTOR. 5. PROVIDE ACCESS TO ANY LANDLORD EQUIPMENT, VALVES, DAMPERS, CLEANOUTS, JUNCTION BOXES, ETC. LOCATED ABOVE GYPSUM BOARD CEILING AREAS. VERIFY WITH LANDLORD PRIOR TO START OF WORK. 6. ALL REQUIRED INTERIOR PHONE CONDUIT WITH PULL STRING SHALL BE SUPPUED BY THE GENERAL CONTRACTOR FROM CASH REGISTER TO DEMARK. 7. DO NOT ATTACH OR SUPPORT ANY ELECTRICAL CONDUITS FROM THE ROOF DECK. HANGERS, CLAMPS, AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. ELECTRICAL PLAN NOTES: TT 4 n 0 8 n 10 m CONNECTION FOR COOLED SHOWCASE. PROVIDE CIRCUITING AS SHOWN IN SLAB IN 3/4 "C. COORDINATE SAW GUTTING OF SLAB WITH ARCHITECT AND OWNER. RECEPTACLE AND DATA OUTLET FOR P05 STATION WITHIN MILLWORK. COORDINATE EXACT LOCATION WITH ARCHITECT/ OWNER PRIOR TO ROUGH -IN. COORDINATE LOCATION OF RECEPTACLES ALONG BACK COUNTER WITH FIXTURE DRAWINGS. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. RECEPTACLES FURNISHED BY FIXTURE SUPPLIER. CIRCUIT AS SHOWN. REFER TO ARCHITECTURAL DRAWINGS FOR MORE INFORMATION. PROVIDE DUPLEX RECEPTACLE FOR MUSIC SYSTEM. VERIFY EXACT LOCATION WITH ARCHITECT /OWNER PRIOR TO ROUGH-IN. CUT FLOOR TO STOREFRONT DIPPER AND PROVIDE (2) DUPLEX RECEPTACLES IN FLUSH FLOOR BOX WITH BRASS COVER. CONNECT ONE RECEPTACLE TO SWITCHED CIRCUIT AND LABEL RECEPTACLE "POWER ". CONNECT OTHER RECEPTACLE TO CIRCUIT INDICATED ON E -2.0. COORDINATE FLOOR BOX LOCATION WITH FIXTURE DRAWINGS. PATCH FLOOR TO MATCH EXISTING. PROVIDE (2) 1" CONDUITS WITH PULL WIRE UNDER SLAB AS SHOWN TO BACK WALL. ROUTE DATA CONDUITS OVERHEAD BACK TO STOCK ROOM. NEW " VENTROL" REFRIGERATION AND CONDENSING UNITS PROVIDED BY GODIVA. VENTROL CONDENSING UNIT LOCATED ON ROOF. LOCATION TO BE DETERMINED. COORDINATE FINAL LOCATION OF CONDENSING UNIT WITH LANLORD PRIOR TO INSTALLATION. NEW SUSPENDED 45KVA TRANSFORMER ABOVE CEILING. REFER TO DETAIL 3, THIS SHEET, FOR FURTHER INFORMATION. EXISTING REMOTE STOCK ROOM. NO ELECTRICAL WORK TO BE PERFORMED TO EXISTING SPACE. PROVIDE EDWARDS SIGNALING AND SECURITY SYSTEM PULL CORD #6537 IN HANDICAPPED RESTROOM FOR STAND -ALONE CALL -FOR- AID SYSTEM. PROVIDE POWER THROUGH CIRCUIT L -27. PROVIDE EDWARDS SIGNALING AND SECURITY SYSTEM HORN/ STROBE #6536-G5 IN HANDICAPPED RESTROOM FOR STAND -ALONE CALL-FOR-AID SYSTEM. RECraVET FEB - 8 2008 PERMIT CENTEL HENDERSON ENGINEERS= 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hel- eeg.com 0750001294 RJS JMH SIM 4325 Tam -O- Shanter Way, Dayton, OH 454291 p 937.477.2334 j info ®moda4.com 12/18/ Q V 1 1 4 W 0 F. Z F-- Q W '- (i) 0 N O 0 0- MODA4 PROJECT NUMBER: 07009 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT 12.17.07 01.03.08 01.11.08 01.25.08 ELECTRICAL POWER PLAN E -2.1 2 3 4 5 6 7 8 9 10 LCK C1 C2 C1 C1 /EM C2 01 C1 C1 LCK LCK LCK LO PANELBOARD: H (NEW) FAULT CURRENT: SEE RISER DIAGRAM EQUIPMENT GROUND BUS BUS AMPS: 225A AIC RATING:14,000 FULLY RATED MAIN SIZE /TYPE: 200A MCB SERVES: FIRST FLOOR VOLTS /PHASE: 480Y/277V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: ELECTRICAL ROOM, ROOM #:100 CKT NO. DESCRIPTION VOLTAMPS PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS PHASE DESCRIPTION CKT NO. A B C A B C 1 PWR - CU -1 1,657 ' / i /// 20 3 3 70 12,554 // /' // 2 3 pr 1,657 %j %j/%i 12 4 „//j/� 11,614 `/jjjje PNLBD L THRU 45KVA XFMR 4 5 �jj/� J,%C/,/,I 1,657 F/jjjj/AVOEjj4 11,691 TXL LTG - BACK BAR LTG OgIl SPARE �i%/jj F/j//jj/�I- wyox/�F/jjjjj�■■■� ///dV,,,/ 20 1 11 20 12 �% r/` SPARE SPARE 587 1,200 /%/% 20 20 MI 20 20 /j,�///,1 �jQjQJ . SPARE SPARE TOTAL AMPACITY 11 SPARE ® SPARE fir%// / /j/ir/////jiJMIN 20 H0 20 IIIIIIIIIIMIII�j,/%/,%Ai ,ff/.- SPARE Ea 15 SPARE V///jj/'- id 20 1 1 20 �F/jjjjj,�IMINIVja SPARE 16 17 SPARE Pl2. Ar/jjjjj/JIIIIIIIIN 12 20 1 1 20 �VAff..jaPM.1 M11111111111111111 SPARE 18 SUBTOTAL 1,657 1,657 1,657 12 12,554 11,614 11,691 SUBTOTAL TOTAL PHASE A - VA 14,211 LOAD CONN. VA DF 1 LOAD CONN. VA DF %% // REFRIGERATION 3 556 1.00 AMPS 51 COOLING 6,947 1.00 HEATING 478 0 TOTAL PHASE B - VA 13,271 SIGN /DISPLAY 3,600 1.25 LIGHTING 2 214 1.25 AMPS 48 KITCHEN 12 1.00 RECEPTACLES 2,880 1.0/.5 1.00 EXISTING pr. 4017,A 1.00 TOTAL PHASE C -- VA 13,348 AMPS 48 MOTORS 1,492 LARGE MOTOR 20 1.25 TOTAL DEMAND 20 TOTAL PNLBD - VA 40,830 SUPP HEAT 10,752 1.00 SHOW WINDOW 6,050 1.25 49,067 VA AMPS 49 MISC EQUIP 8,610 1.00 LTG TRACK 12 1.00 59 A 'PANELBOARD NOTES LCK - LOCKABLE OFF (FOR MAINTENANCE) LTG TRACK - TRACK LENGTH SIGN /DISPLAY - SIGNAGE & DISPLAY CASE PANELBOARD: L (NEW) FAULT CURRENT: SEE BUS AMPS: 225A AIC RATING:10,000 MAIN SIZE /TYPE: 150A MCB SERVES: GODIVA CHOCOLATIER VOLTS /PHASE: 208Y/120V, 3PH, 4W MOUNTING: SURFACE SECTION: 1 LOCATION: STOCK RISER DIAGRAM EQUIPMENT GROUND BUS FULLY RATED ROOM CKT NO. DESCRIPTION VOLTAMPS /PHASE WIRE NO. BKR AMP P P BKR AMP WIRE NO. VOLTAMPS /PHASE I DESCRIPTION CKT NO. A I B I C A I B I C j 1 LTG - BAR DISPLAY LTG 1,040 �/1e�/ i / 12 12 20 20 1 1 2 15 12 587 ` 1/1/11 1 PWR - FCU -1 2 4 3 LTG - COUNTER TOP S WIND � 7 5 LTG - BACK BAR LTG �jj/j/' 240 12 20 1 1 20 12 �� 587 1,200 /%/% LTG - WINDOW SIGNAGE SPARE 6 8 12 20 1 1 20 TOTAL AMPACITY 56.79 / // 7 LTG - GENERAL LTG + EM 286 , , 9 LTG - SALES ACCENT LTG % /// 160 '////// 12 20 1 1 20 12 / /// / 696 / / / / //i PWR - VAV -1 10 11 RCPT - SHOW WINDOW �/ /// 540 12 20 1 1 20 12 �/ ///r/ � //j 193 LTG - COUNTERTOPS 12 13 LTG - STOCK /RESTROOM 450 '77 '/ % / / /// 12 20 1 1 20 12 1.080 %% // % / / /// RCPT - CONV. RCPTS 14 15 LTG - SLAB SHELVES /CORE ' 1,040 ' 12 20 1 1 20 12 ' 160 ' // 7 1,000 LTG - CORE CABINETS 16 17 PWR - EXTERIOR SIGNAGE 2 fjjjj/)r/jjjjjA 1,200 12 20 1 1 20 12 pr. 4017,A j PWR - UC REFRIGERATOR 18 19 RCPT - REFRIGERATOR 1,200 For jj %/J`/j %jjj 12 20 1 1 20 12 720 P Adr/ y � 7 //i RCPT - ISLAND REGISTERS PWR - BLENDER 1 20 22 21 RCPT - ICE MACHINE 1,056 i 12 20 1 1 20 12 1,500 23 SPARE %/ 20 1 1 20 12 // // ' / / / / //i 1,000 PWR - VENTROL EVAP. UNIT 24 25 SPARE ' 7/ ' 20 1 1 20 "` i / //// i SPARE 26 27 PWR - CALL FOR AID SYSTEM r/%jjjj/,,I 360 r/jjjj/ 12 20 1 1 20 r/jjjj/� jj SPARE 28 29 PWR - VENTROL COND. UNIT wjjj�r/jjjjj�l 988 12 _ _ 12 15 _ 20 2 __ 1 3 50 8 pjjjjj�r%jjjji 2,880 PWR - WATER HEATER EQ --27A RCPT - HOT POT 30 31 4,992 jj r/jj1 2,880 7j j A 800 988 %jjj//�r/ /jj /j 32 34 36 33 PWR - HEAT GUN 500 rQ'jj 35 PWR - SHRINK WRAP rijjjj/�F/jjjjjA 500 12 20 1 1 20 12 ri/'j 37 PWR - TS /CONTACTORS 250 I%QjjAF/jjpj 12 20 1 1 20 12 1,200 F/jjj PWR - EXTERIOR SIGNAGE 1 38 40 39 PWR - COOLED SHOWCASE %jjjj� 1,000 r%j,Q/Or 12 20 1 1 20 12 r0'/jjj/J 1.500 j PWR - BLENDER 2 41 PWR - COOLED SHOWCASE LTG 150 12 20 1 1 20 12 / i / i 1,000 PWR -- COUNTER REFRIG 42 SUBTOTAL 4,214 4,291 3.618 8,579 7.323 8.073 SUBTOTAL TOTAL PHASE A --- VA 12,793 LOAD CONN. VA DF LOAD CONN. VA DF REFRIGERATION 3,556 1.00 AMPS 107 COOLING 1,976 1.00 HEATING 478 0 TOTAL PHASE B - VA 11,614 SIGN /DISPLAY KITCHEN 3,600 1.25 LIGHTING 2,214 1.25 1.00_ 1.00 AMPS 97 TOTAL PHASE C - VA 11,691 RECEPTACLES 2 880 EXISTING 1.0/.5 MOTORS 796 1.00 LARGE MOTOR 696 1.25 TOTAL DEMAND AMPS 97 TOTAL PNLBD - VA 36,098 SUPP HEAT 10,752 1.00 SHOW WINDOW 6,050 1.25 44,270 VA AMPS 100 MISC EQUIP 8,610 1.00 LTG TRACK 1.00 123 A PANELBOARD NOTES LCK - LOCKABLE OFF (FOR MAINTENANCE) C# - VIA LTG CONTACTOR # LO --- HANDLE TAB-ON LTG TRACK - TRACK LENGTH EM - EMERG LTG /LOCKABLE TAB SIGN /DISPLAY - SIGNAGE & DISPLAY CASE TENANT ELECTRICAL SERVICE LOAD SUMMARY BUILDING OCCUPANCY TYPE: M I BUILDING SQUARE FOOTAGE: 950 I SERVICE DESCRIPTION: 480Y/277V, 3PH 4W LOAD DESCRIPTION I Connected KVA Demand FACTOR Demand KVA HVAC - SUMMER 6.95 100% 6.95 HVAC - WINTER 0.48 100% 0.00 LIGHTING (PER NEC -220) 2.85 125% 3.56 RECEPTACLES 2.88 1 00%;50% 2.88 MOTOR LOADS 0.80 100% 0.80 LARGEST MOTOR LOAD 0.70 125% 0.87 SUPPLEMENTAL ELECTRTC HEAT 10.75 100% 10.75 MISCELLANEOUS EQUIPMENT 8.61 100% 8.61 REFRIGERATION EQUIPMENT 3.56 100% 3.56 DISPLAY CASE /SIGNAGE 3.60 125% 4.50 SHOW WINDOW / TRACK LIGHTING 6.05 PER NEC 7.56 TOTAL LOAD 47.22 KVA 50.04 TOTAL AMPACITY 56.79 AMPS 60.18 SERVICE AMPACITY 200 AMPS 200.00 SPARE CAPACITY AMPS 140 LCK C2 LCK 01 01 LO LCK LCK LCK 02 M2 `AC- /2 fl oiZm,G4 1 s /1)E.4 -4 Plitz e1 / 6 ELECTRICAL KEYED NOTES: Fri 1200A DISCONNECT SWITCH PROVIDED BY THE LANDLORD FOR THE GODIVA CHOCOLATIER SPACE. EI PROVIDE IDENTIFICATION NAMEPLATE ON GODIVA'S DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. REFER TO TENANT CRITERIA FOR NAMEPLATE REQUIREMENTS. ELECTRICAL GENERAL NOTES: 1. INCLUDE GROUND WIRE IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH N.E.C. 2. VERIFY EXACT LOCATION OF ELECTRICAL DEVICES SHOWN ON THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MECHANICAL, AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. 3. PROVIDE A TYPED LISTING OF FINAL CIRCUIT ASSIGNMENTS PERMANENTLY ATTACHED TO PANELBOARDS WITH COPIES TO THE MANAGER AND OWNER. 4. BALANCE ALL PANELBOARDS AND ELECTRICAL EQUIPMENT TO +/- 10% BETWEEN PHASES: A /B, B /C, A/C REGARDLESS OF CIRCUITING INDICATED. 5. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 6. CONDUCTORS IN ONE -LINE DIAGRAMS MAY BE UPSIZED FOR VOLTAGE DROP. REPORT CHANGES TO ENGINEER. 7. FAULT CURRENT CALCULATED USING AN INFINITE BUS. VERIFY AND REPORT ACTUAL FAULT CURRENT FOR VERIFICATION OF DRAWINGS. 8. TELEPHONE CONDUIT TO BE ROUTED FROM DEMARK TO TELEPHONE TERMINAL BOARD IN GODIVA'S SPACE. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE A TEMPORARY TRANSFORMER AND PANEL AS NECESSARY FOR CONSTRUCTION POWER. EXISTING LA\DLORD METERING EQUIPMENT LANDLORD ELECTRICAL ROOM 1 B 480Y/277V 30 4W FCA= 18,437A EXISTING NEW TENANT SPACE #1020 --- BY TGC 200/3/200 11 CVD= 0.3% FCA= 10,370A PNLBD H TXL -I 45KVAq 1480Y 277V _1208 /120V CVD= 0.5% FCA= 3,084A PNLBD L CIRCUIT SCHEDULE: ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN /THWN -2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70. 73 204 G150 I- T154 ONE -LINE DIAGRAM NO SCALE 70A, (3) #4, (1) #8G, 1" C 200A, (4) 0/0, (1) #6G, 2" C GND, #6 COPPER GROUND, 3/4" C 150A, (4) #1/0, (1) #6G, 1-1/2" C LIGHTING CONTACTOR SCHEDULE CONTACTOR NUMBER CONTACTOR CONTROL CIRCUIT LOAD DESCRIPTION AMPS POLES CIRCUIT NO. VOLTS OPERATION BY C1 30 10 L- -1,5,7,11,12,15,16,17 120 TS ON/TS OFF SALES FLOOR LIGHTING C2 30 6 L- 3,6,9,28 120 TS ON/TS OFF SHOW WINDOW, SIGNAGE CONTACTOR NOTES: 1. PROVIDE MECHANICALLY HELD CONTACTORS. REFER TO SPECIFICATIONS. 2. PROVIDE ALL REQUIRED CONTROL ACCESSORIES NECESSARY FOR OPERATION AS DESCRIBED ABOVE. 3. PROVIDE LABELS FOR EACH CONTACTOR INDICATING THE LOADS CONTROLLED AND CONTROL CIRCUIT NUMBERS. 4. NUMBER ALL CONDUCTORS AT EACH CONTACTOR. 5. PROVIDE EACH CONTACTOR WITH MINIMUM OF (1) SPARE POLES, IN ADDITION TO ACTIVE POLES INDICATED. 6. REFER TO PANELBOARD SCHEDULE FOR CONTROL CIRCUITING INFORMATION. . ABBREVIATIONS: TS = TIMESWITCH RECEIVE FEB - 8 2008 PERM11 CEN1 h REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR 2 6 2008 City Tukwila BUILDIN DWI I! N HENDERSON ENGINEERS"" =_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TU. 713 783 7707 FAX 713 783 7797 www.Nei- eng.cem 0750001294 RJS JMH SIM 4325 Tam- O- Shanter Way, Dayton, OH 454291 p 937.47723341 info @moda4.00m i 0 U Ifta 555 Southcenter MODA4 PROJECT NUMBER: 07009 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 ELECTRICAL PNLBD SCHED AND DETAILS E -3.0 1 2 3 6 7 8 9 10 1 6A: ELECTRICAL: 16A1 GENERAL CONDITIONS: A. THE REQUIREMENTS AS SET FORTH UNDER GENERAL CONDITIONS, INSTRUCTIONS TO BIDDERS AND GENERAL REQUIREMENTS ARE A PART OF THIS CONTRACT. B. BIDS SHALL BE BASED ON A COMPLETE /FULL SET OF DRAWINGS. C. CONTRACTOR MUST READ THE ENTIRE SPECIFICATIONS COVERING OTHER BRANCHES OF WORK AND IS RESPONSIBLE FOR COORDINATION OF THE WORK WITH WORK PERFORMED BY OTHER TRADES. 16A2 SCOPE OF WORK: A. CONTRACTOR SHALL VISIT SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS. ALL REQUIREMENTS INCLUDING MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS ARE TO BE OBTAINED BY ELECTRICAL CONTRACTOR PRIOR TO AND INCLUDED IN BID PRICE. FIELD VERIFY ALL EXISTING ELECTRICAL AND TELEPHONE EQUIPMENT, LOCATIONS, CONDITIONS ETC. FAILURE TO VISIT THE SITE SHALL NOT RELIEVE THE CONTRACTOR FROM ANY RESPONSIBILITY IN THE PERFORMANCE OF THE ELECTRICAL WORK. B. FURNISH ALL LABOR, MATERIALS, TESTING, EQUIPMENT, INCIDENTALS AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 1. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW AND AS SUCH APPEAR ON THE UNDERWRITERS LABORATORIES LIST OF APPROVED ITEMS AND SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND OTHER APPLICABLE CODES, WHICHEVER ARE MORE STRINGENT. C. THE WORK IS TO BE IN ACCORDANCE WITH THE LATEST EDITION OF THE NEC AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. D. INCLUDE ANY LABOR AND MATERIALS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO PROVIDE A COMPLEIL AND FULLY OPERATIVE ELECTRICAL SYSTEMS. 16A3 PERMITS: A. SECURE AND PAY FOR ALL REQUIRED PERMITS, FEES, ASSESSMENTS AND INSPECTION CERTIFICATES THAT RELATE TO THE ELECTRICAL CONTRACT. B. FURNISH APPROVED CERTIFICATE OF FINAL INSPECTION, AND TURN OVER TO OWNER AT COMPLETION OF PROJECT. 16A4 DRAWINGS AND SPECIFICATIONS: A. THESE ELECTRICAL PLANS ARE DIAGRAMMATIC, NOT SHOWING EVERY ITEM IN EXACT LOCATION OR DETAIL. MEASUREMENTS AND LOCATIONS MUST BE FIELD VERIFIED AND COORDINATED WITH ARCHITECTURAL, PLUMBING, HVAC, FIRE PROTECTION, STRUCTURAL AND OTHER BUILDING DRAWINGS. 16A5 SHOP DRAWINGS: A. SUBMIT FIVE COPIES OF MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S CONSTRUCTION MANAGER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS EARLY ENOUGH IN PROJECT TO ALLOW AMPLE TIME FOR OWNER'S REVIEW WITHOUT CAUSING TIME DELAYS OR CONFLICTS IN THE JOB PROGRESS. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND THE MANUFACTURERS LISTED ON THE DRAWINGS AND SHALL BEAR THE STAMP OF THE CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM AND THAT THEY ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. B. WHERE TRADE NAMES, BRANDS OF MANUFACTURERS OF EQUIPMENT OR MATERIALS ARE SHOWN ON THE DRAWINGS OR SPECIFICATIONS THE EXACT EQUIPMENT SHALL BE USED ON THE PROJECT. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL /REPLACEMENT AT THE REQUEST OF THE OWNER'S CONSTRUCTION MANAGER (AT THE ELECTRICAL CONTRACTORS EXPENSE). 16A6 CONDUITS: A. CONDUIT SHALL BE STANDARD STEEL RIGID, IMC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY ARCHITECT. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. B. FLEXIBLE METAL CONDUIT SHALL BE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND VIBRATING EQUIPMENT ONLY; AND WHERE SO USED TO BE GROUNDED WITH A SEPARATE FULL SIZED GREEN GROUNDING CONDUCTOR. FINAL FLEXIBLE METAL CONDUIT CONNECTIONS SHALL BE LIMITED TO 5' -0" IN LENGTH. (ARRANGE CIRCUITS 50 AS TO AVOID THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED ABOVE LAY IN CEILINGS ARE ACCEPTABLE). 1. MINIMUM SIZES OF CONDUITS SHALL BE 3/4 ". ELECTRIC METALLIC TUBING (EMT) SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. FITTINGS SHALL BE SET SCREW OR I SHALL BE AS MANUFACTURED BY REGEL, STEEL CITY RACO, COMPRESSION TYPE, FITTING HALL E T & B, EFCOR OR EQUAL. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE SUSPENDED CEIUNGS OR CONCEALED IN INTERIOR PARTITIONS. 2. PAINTING OF ELECTRICAL CONDUITS, ETC., IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. C. THE USE OF AC, MC, NM, ROMEX, OR BX IS NOT PERMITTED. D. MAXIMUM CONDUIT HANGER SPACING SHALL BE 8'--0" FOR 3/4" THRU 1 1/4" AND 10' -0" FOR 1 1/2" THRU 4" CONDUITS. DO NOT SUPPORT CONDUIT FROM THE CEILING SYSTEM. E. LEAVE A #10 AWG PULL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS. F. SECURE ALL RACEWAYS TO THE BUILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS "CADDY CUPS" OR EQUAL. G. FLASH AND COUNTER FLASH ALL RACEWAYS WHICH PENETRATE THE ROOF OR USE PITCH POCKETS. INSURE THAT PENETRATIONS ARE COMPLETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO THE WEATHER SHALL BE WEATHERPROOF. PRIOR APPROVAL BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRUCTURE OR TO MAKE HOLES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 72 HOURS PRIOR TO ANY REQUIRED ROOF WORK. H. SLAB OPENINGS FOR CONDUITS IN WET AREAS MUST BE SLEEVED 2" ABOVE FLOOR AND SEALED TO PROPER FLOOR WATERPROOFING SYSTEM PER B -2. X -RAY SLAB PRIOR TO CORE DRILLING. 16A7 WIRE: A. WIRE SHALL BE SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MINIMUM WIRE SIZE SHALL BE #12 AWG, ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. ALL WIRING OF ANY TYPE SHALL BE IN CONDUIT. NO STRANDED WIRE ALLOWED FOR #10 AND #12 AWG SIZES. (INCREASE CONDUCTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD FOR 120 VOLT CIRCUITS.) 1. GENERAL WIRING SHALL BE THW OR THHN. (ALUMINUM CONDUCTORS ARE NOT PERMITTED.) B. C. D. ALL WIRING TO BE COLOR CODED AS FOLLOWS: WIRE CONNECTORS SHALL BE EQUAL TO SCOTCHLOCK FOR #8 AND SMALLER, AND EQUAL TO T & B "LOCK -TITE" FOR #6 AND LARGER. THE USE OF SHARED NEUTRALS IS ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF INSTALLED IN ACCORDANCE WITH N.E.C. #310, AND LOCAL CODES. 120/208 VOLT SYSTEM NEUTRAL - WHITE PHASE A OR L1 -BLACK PHASE B OR L2 -RED PHASE C OR L3 -BLUE GROUND -GREEN 277/480 VOLT SYSTEM NEUTRAL - WHITE WITH TRACER OR GRAY PHASE A OR L1 - BROWN PHASE B OR L2- ORANGE PHASE C OR L3- YELLOW GROUND -GREEN WITH TRACER 16A8 LIGHTING: A. LIGHTING FIXTURES AND LAMPS SHALL BE FURNISHED AS SCHEDULED ON THE LIGHTING FIXTURE SCHEDULE. (THE MAJORITY OR THE FIXTURES AND LAMPS ARE FURNISHED BY THE TENANT) ELECTRICAL CONTRACTOR SHALL INSTALL ALL FIXTURES AND LAMPS. FLUORESCENT FIXTURES SHALL HAVE HPF BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH "NATIONAL APPLIANCE ENERGY CONSERVATION ACT OF 1987, AMENDMENTS OF 1988." B. LIGHT FIXTURES SHALL BE SUPPORTED FROM THE BUILDING STRUCTURAL VIA ALL THREAD AND UNISTRUT, AND NOT SUPPORTED BY CEILING SYSTEM. 16A9 WIRED GROUND SYSTEM: A. FURNISH AND INSTALL A COMPLETE WIRED GROUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOWN ON THE DRAWINGS AND DESCRIBED GENERALLY BELOW. B. ALL GROUNDING CONDUCTORS SHALL BE GREEN, WHERE EXPOSED IN PANEL, SWITCHBOARD, OUTLET, BOXES, ETC. C. ALL ENCLOSURES AND NON CURRENT CARRYING METALS TO BE GROUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. D. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, #12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS BOND THE GROUNDING CONDUCTOR TO THE CONDUIT, WHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SHALL BE PENN -UNION OR EQUAL, SIMILAR TO "GPL" TYPE. CONDUIT GROUND BUSHINGS SHALL BE THOMAS & BETTS OR EQUAL, SIMILAR TO #3800 SERIES WITH NYLON INSULATED THROAT. E. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL TO METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX 15 NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT SHALL BE JUMPERED WITH A GROUND CONDUCTOR. 16A10 WIRE DEVICES: A. COLOR OF WIRING DEVICES SHALL BE IVORY. 1. RECEPTACLES SHALL BE 20 AMP, 3 -WIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. 2. SWITCHES SHALL BE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 277 VOLT, AS REQUIRED. 3. SPECIAL DEVICES SHALL BE A SPECIFICATION GRADE. 4. ALL DEVICE COVER PLATES SHALL BE BRASS. 5. FLOOR BOXES TO BE HUBBELL #B- 2527/29 WITH S -3925 BRASS COVER (OR EQUAL BY "STEEL CITY ") AND HUBBELL 5362 RECEPTACLE (UNLESS OTHERWISE NOTED). 6. EQUAL BY ARROW -HART, GENERAL ELECTRIC, BRYANT, PASS & SEYMOUR, OR SIERRA. 16A11 PANELBOARDS AND SAFETY SWITCHES: A. PROVIDE BRANCH CIRCUIT PANELS WHICH SHALL BE OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL HINGED /LOCKABLE DOOR, AND TYPE WRITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SHALL BEAR THE MANUFACTURER'S LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITH N.E.C. #230-70. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITCHBOARDS. TWO AND THREE P011 BREAKERS SHALL BE COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 277V. LIGHTING CIRCUITS, FURNISH TYPE "SWD" BREAKERS IN ACCORDANCE WITH N.E.C. #240 -83B. SQUARE D OR EQUAL BY GOULD ITE, CUTLER - HAMMER, WESTINGHOUSE, CHALLENGER, FEDERAL PACIFIC, OR GENERAL ELECTRIC (OR APPROVED EQUAL). B. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON FUSED, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FUSES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, WESTINGHOUSE, ECONOMY FUSE CO., OR LITTLE FUSE CO. ARE ACCEPTABLE). DISCONNECT SWITCHES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, HEAT PUMPS, ETC. SHALL BE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIREMENTS PER N.E.C. 440 -21 & 110 -3B. SWITCHES SHALL BE HEAVY DUTY, QUICK MAKE /QUICK BREAK TYPE, FUSIBLE OR NON FUSIBLE, WEATHERPROOF AS INDICATED ON THE DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE D, GOULD ITE, CHALLENGER, CUTLER HAMMER, WESTINGHOUSE, FEDERAL PACIFIC, OR GENERAL ELECTRIC (OR APPROVED EQUAL). C. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE USED FOR FRACTIONAL HORSEPOWER MOTORS THAT DO NOT REQUIRE AUXILIARY CONTROL. SINGLE PHASE STARTERS SHALL BE SQUARE D OR EQUAL. THREE PHASE STARTERS SHALL BE PROVIDED WITH OVERLOAD DEVICE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR STARTERS (MINIMUM SIZE #1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP OR THAT REQUIRE AUXILIARY CONTROL PROVIDE CONTROL DEVICES (CONTACTS, TRANSFORMERS, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS, COORDINATE WITH MECHANICAL AND /OR TEMPERATURE CONTROL CONTRACTORS. COMBINATION STARTERS, WHEN USED, SHALL CONTAIN FUSIBLE SWITCHES. 16Al2 BOXES: A. OUTLET BOXES AND COVERS SHALL BE GALVANIZED, ONE PIECE PRESSED STEEL KNOCKOUT. B. JUNCTION, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE SIZE. C. INSTALL BOXES RIGIDLY ON BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE /PROPER BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF WALLS ETC. ALL OUTLET BOXES TO HAVE SUITABLE BLOCKING BEHIND THEM TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. D. WHERE A 277 VOLT LIGHT SWITCH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A SUITABLE DIVIDER OR SEPARATE JUNCTION BOXES IN ACCORDANCE WITH NEC AND LOCAL CODES. 16A13 SERVICES: A. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PROVIDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPLICABLE TEMPORARY NEEDS, AND FURNISH EXTENSION CORDS. ANY TEMPORARY WIRING, FUSES, ETC., SHALL BE REMOVED UPON COMPLETION OF THE PROJECT. PROVIDE GROUND FAULT PROTECTION AS REQUIRED BY N.E.C. AND LOCAL CODES. B. PROVIDE ELECTRICAL SERVICE AS SHOWN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIREMENTS PRIOR TO BIDS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH LANDLORD AND POWER COMPANY AS REQUIRED. (PROVIDE EQUIPMENT THAT IS COMPATIBLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVIDE "CABLE UMITERS" IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILITIES PRIOR TO BIDDING PROJECT. C. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENANT'S PREMISES SHALL BE PROVIDED AS REQUIRED FOR A COMPLETE TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. CLOSELY HELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER TO AVOID CONFLICTS. 16A14 STEP -DOWN TRANSFORMER: A. PROVIDE A DRY -TYPE TRANSFORMER OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS AND WITH COILS DESIGNED FOR 150 DEGREES C. RISE ABOVE A 40 DEGREE C. AMBIENT WITH 100% OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. (TWO ABOVE AND FOUR BELOW NORMAL) SOUND LEVEL /DECIBELS SHALL BE IN ACCORDANCE WITH "NEMA" STANDARDS, AND INSTALLATION SHALL INCLUDE KORFOUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MINIMIZE SOUND TRANSMISSION. (MOUNT TRANSFORMER ON SEPARATE VIBRATION ISOLATORS, THESE ARE ADDITIONAL VIBRATION ISOLATORS AND ARE USED IN CONJUNCTION WITH ANY INTEGRAL FACTORY INSTAI 1 FD VIBRATION ISOLATORS.) AS MANUFACTURED BY SQUARE D, HEAVY DUTY, ACME, GENERAL ELECTRIC OR WESTINGHOUSE. 16A15 LIGHTING CONTACTOR: A. WHERE INDICATED ON THE DRAWINGS, CONTACTORS FOR CONTROL OF LIGHTING SHALL BE SQUARE D CLASS 8903, TYPE 'L' IN A NEMA 1 ENCLOSURE, ELECTRICALLY OPERATED, AND ELECTRICALLY HELD. EQUALS BY SIEMENS -ITE, GENERAL ELECTRIC, OR WESTINGHOUSE, NO EXCEPTIONS. TIME SWITCHES FOR CONTROL OF SHOW WINDOW LIGHTING AND SIGNS SHALL BE TORK MODEL NO. W220L, 7 DAY TYPE, WITH RESERVE POWER, OR EQUIVALENT BY SANGAMO OR PARAGON. 16A16 INSTALLATION: A. ALL ELECTRIC WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE FASTENED TO BUILDING STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHEREVER POSSIBLE. EXPOSED CONDUITS SHALL BE IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES OR BEAMS AND SEPARATED AT LEAST 3 INCHES FROM WATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. ALL CONDUCTORS SHALL BE IN CONDUIT, DUCTS OR OTHER CODE APPROVED RACEWAYS. B. ALL LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEPT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC., SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. (ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE POWER SOURCE THRU THE STARTER /DISCONNECT ETC. TO THE MOTOR OR EQUIPMENT IS THE RESPONSIBILITY OR THE ELECTRICAL CONTRACTOR. ALL HVAC RELATED LOW VOLTAGE CONTROL WIRING, CONDUIT AND FINAL CONNECTIONS IS THE RESPONSIBILITY OF THE MECHANICAL/TEMPERATURE CONTROL CONTRACTOR, UNLESS OTHERWISE NOTED ON THE PLANS). C. THE ELECTRICAL CONTRACTOR SHALL DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK UNDER THE ELECTRICAL DIVISION, ANY CUTTING SHALL HAVE PRIOR APPROVAL OF THE LANDLORD. SLEEVES SHALL EXTEND AT LEAST TWO (2 ") INCHES ABOVE FINISHED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THROUGH FIRE RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL BY HILT AFTER CONDUIT /CABLES INSTALLATION SO AS TO RETAIN THE FIRE RATING. D. E F. G. H. THE ELECTRICAL CONTRACTORS, INSOFAR AS THE WORK IS CONCERNED, SHALL AT ALL TIMES KEEP THE PREMISES IN A NEAT AND ORDERLY CONDITION AND, AT THE COMPLETION OF THE WORK, SHALL PROPERLY CLEAN UP AND CART AWAY ANY DEBRIS AND EXCESS MATERIAL. THE FOLLOWING EQUIPMENT SHALL BE IDENTIFIED WITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND /OR FUNCTION; DISTRIBUTION PANELS, LIGHTING PANELS, MOTOR STARTERS AND DISCONNECT SWITCHES. NAMEPLATES TO BE APPROXIMATELY 1" X 2" IN SIZE AND BE FASTENED WITH POP RIVETS OR SCREWS. THE LOCATION OF OUTLETS AND EQUIPMENT SHOWN ON THE DRAWINGS ARE APPROXIMATE AND THE ARCHITECT /TENANT CONSTRUCTION MANAGER SHALL HAVE THE RIGHT TO RELOCATE ANY OUTLETS OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDMONAL COST. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN THE WORK AS THE JOB PROGRESSES, AND TURN THIS "AS BUILT" INFORMATION OVER TO THE OWNER AT THE COMPLETION OF THE PROJECT. ELECTRICAL CONTRACTOR SHALL PROTECT ALL FIXTURES /EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABUSE, ETC., AND PAY COST OF REPAIR OR REPLACEMENT OF FIXTURES OR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. I. ALL ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. AFTER ALL EQUIPMENT HAS BEEN INSPECTED AND APPROVED, THOROUGHLY CLEAN ALL EQUIPMENT PROVIDED UNDER THIS WORK JUST PRIOR TO COMPLETION OF PROJECT. J. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR ANY /ALL NECESSARY ELECTRICAL DEMOLITION WORK THAT IS REQUIRED TO FACILITATE THE NEW INSTALLATION, FIELD COORDINATE PRIOR TO BIDS. REMOVE AND /OR MODIFY EQUIPMENT, ETC. AS REQUIRED A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE REMAINING IN USE AFTER PART THE EQUIPMENT OR DEVICES HAVE BEEN REMOVED ARE TO BE RECONNECTED TO EXISTIN OR NEW CIRCUITS AND LEFT IN WORKING ORDER. FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO BE ROUTED CONCEALED IN FINISHED AREAS. COORDINATE ANY DISRUPTION OF ELECTRICAL OR TELEPHONE SERVICES WITH LANDLORD AND TENANT CONSTRUCTION MANAGER TO AVOID CONFLICTS. 16A17 GUARANTEE: A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THE ELECTRICAL CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND /OR INSTALLED BY THE ELECTRICAL CONTRACTOR. 4325 Tam-O-Shanter Way, Dayton, OH 454291 p 937.477.23341 Info @moda4.com / ~6)1 12108108 i► .v V 0 Co) Cas:) J J 4 Q rig DW 2'- CODE COMPLIANCE . Z NFPA 70 - NEC z W Q0 w I 1 MAR 2 6 2088 City Of Tukwila BUILDING DIVISION 16A18 TELEPHONE: A. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLLIE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITIED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UIIUZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. 16A19 FINALLY: A. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. RECEWEF. FEB - 8 2008 PERMIT GEN I - riHENDERSON ENGINEERSN 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 m.7137837707 Fax 713 783 7797 www.hei-eng.com 0750001294 RJS JMH SI M 0 555 Southcenter co co O CO N Ci7 O < w U p- a) CO CI) MODA4 PROJECT NUMBER: 07009 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW HEALTH DEPT RVSNS ISSUED FOR PERMIT 01.03.08 01.11.08 01.25.08 ELECTRICAL SPECIFICATIONS E -4.0 6 7 8 9 10 SECTION 1 6C FIRE ALARM SYSTEM: 16C1 GENERAL 16C 1 -1 GENERAL REQUIREMENTS THE WORK COVERED BY THIS SECTION OF THE SPECIFICATIONS INCLUDES THE FURNISHING OF ALL LABOR, EQUIPMENT, AND MATERIAL AS HEREIN SPECIFIED. THIS SECTION REQUIRES THE CONTRACTOR TO FURNISH ALL MATERIALS REQUIRED TO INSTALL THE FIRE ALARM SYSTEM. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING, TESTING, AND START -UP OF A COMPLETE FUNCTIONING FIRE ALARM SYSTEM, AND EACH ELEMENT THEREOF, AS SPECIFIED OR INDICATED ON THE DRAWINGS OR REASONABLY INFERRED, INCLUDING EVERY ARTICLE, DEVICE OR ACCESSORY (WHETHER OR NOT SPECIFICALLY CALLED FOR BY ITEM) REASONABLY NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTION AS INDICATED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. ELEMENTS OF THE WORK INCLUDE MATERIALS, LABOR, SUPERVISION, SUPPLIES, EQUIPMENT, TRANSPORTATION AND UTILITIES. INSTALLATION OF DEVICES SHALL BE PERFORMED OR SUPERVISED BY A NATIONAL INSTITUTE FOR CERTIFICATION OF ENGINEERING TECHNOLOGIES (NICET) LEVEL 2 OR HIGHER FIRE ALARM TECHNICIAN. SUBMIT COPIES OF THE CERTIFICATION FOR EMPLOYEES THROUGH SHOP DRAWING SUBMITTALS. 16C 1 -2 SCOPE OF WORK THE SCOPE OF WORK IN THIS SECTION INCLUDES: EXTENSION OF THE EXISTING LANDLORD'S FIRE ALARM SYSTEM FOR NEW TENANT SPACE TO INCLUDE FIRE ALARM NOTIFICATION APPLIANCES; AUXILIARY FIRE ALARM EQUIPMENT; SPRINKLER SYSTEM WATERFLOW AND VALVE TAMPER ALARMS; AIR HANDLING UNIT SHUTDOWN; DUCT SMOKE DETECTORS. 16C 1 -3 CODES AND STANDARDS PROVIDE AN INTEGRATED FIRE ALARM SYSTEM, WHICH MEETS THE CURRENT VERSIONS OF NFPA 70, NATIONAL ELECTRICAL CODE; NFPA 72, NATIONAL FIRE ALARM CODE; AND ALL LOCAL BUILDING AND FIRE CODES. ALL FIRE ALARM EQUIPMENT SHALL BE UNDERWRITERS LABORATORY (UL) OR FACTORY MUTUAL (FM) APPROVED FOR THE TYPE AND CLASS OF SERVICE PERFORMED. 16C 1 -4 SYSTEM DESCRIPTION THE FIRE ALARM SYSTEM SHALL BE A NON -CODED MANUAL AND AUTOMATIC FIRE ALARM SYSTEM WITH CONNECTION TO THE EXISTING LANDLORD'S FIRE ALARM CONTROL PANEL. CONTROL PANEL IS EXISTING TO REMAIN IN LANDLORD SPACE. 16C 1 -5 SUBMITTAL REQUIREMENTS SUBMIT A DETAILED SEQUENCE OF OPERATION. PRE-PRINTED, GENERIC MATERIAL WILL NOT BE ACCEPTED AND WILL BE REJECTED. SHOP DRAWINGS SHOWING FIRE ALARM FLOOR PLANS AND A FULL BUILDING RISER DIAGRAM. FIRE ALARM FLOOR PLANS AND RISER DIAGRAM SHALL SHOW FIRE ALARM CONTROL PANEL, ANNUNCIATOR, ALL FIRE ALARM INITIATING DEVICES AND NOTIFICATION APPUANCES. SHOW TYPICAL WIRING DIAGRAMS OF CONTROL PANEL /S, ANNUNCIATOR AND EACH DEVICE AND WIRING CONNECTIONS REQUIRED. SHOW ALL INTERFACES TO OTHER SYSTEMS, SUCH AS TEMPERATURE CONTROL SYSTEMS, AND SECURITY SYSTEMS. SUBMIT A BILL OF MATERIAL AND MANUFACTURERS PRODUCT DATA FOR ALL DEVICES AND EQUIPMENT. 16C 1 -6 QUALIFICATIONS THE MANUFACTURER SHALL BE A COMPANY SPECIALIZING IN MANUFACTURING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE. THE INSTALLER SHALL BE A COMPANY SPECIALIZING IN INSTALLING THE PRODUCTS SPECIFIED IN THIS SECTION WITH MINIMUM THREE YEARS DOCUMENTED EXPERIENCE. SHALL BE BONDABLE AND LICENSED CONTRACTOR AND MERCHANT OF ELECTRONIC AUTOMATED FIRE ALARM SYSTEMS AND EMPLOY FULL -TIME FACTORY- TRAINED INSTALLERS AND TECHNICIANS. THE EQUIPMENT MANUFACTURER'S SERVICE DEPARTMENT SHALL BE FULLY STOCKED IN STANDARD PARTS AND COMPONENTS AND ENGAGED IN THE MAINTENANCE OF FIRE ALARM SYSTEMS. ON- THE - PREMISES SERVICE SHALL BE AVAILABLE WITHIN 4 HOURS OF NOTIFICATION, 7 DAYS A WEEK, 24 HOURS A DAY. FURNISH SERVICE AND MAINTENANCE OF FIRE ALARM SYSTEM FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. 16C 1 -7 SERVICE AND GUARANTEE FURNISH SERVICE AND MAINTENANCE OF FIRE ALARM SYSTEM INCLUDING WIRING AND RACEWAYS FOR ONE YEAR FROM DATE OF SUBSTANTIAL COMPLETION. ALL COMPONENTS, SYSTEM SOFTWARE, PARTS AND ASSEMBLIES SHALL BE GUARANTEED AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP FOR ONE -YEAR. LABOR (INCLUDING TRAVEL EXPENSES) TO TROUBLE - SHOOT, REPAIR, REPROGRAM, OR REPLACE COMPONENTS SHALL BE FURNISHED BY THIS CONTRACTOR AT NO CHARGE DURING THE WARRANTY PERIOD. ALL CORRECTIVE SOFTWARE MODIFICATIONS MADE DURING WARRANTY PERIODS SHALL BE UPDATED ON ALL USER DOCUMENTATION AND ON USER AND MANUFACTURER ARCHIVED SOFTWARE DISKS. 16 2 EQUIPMENT 16C 2 -1 MANUFACTURERS SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS THAT ARE COMPATIBLE WITH THE EXISTING FIRE ALARM SYSTEM. 16C 2 -2 FIRE ALARM CONTROL PANEL THE FIRE ALARM CONTROL PANEL IS EXISTING TO REMAIN IN LANDLORD SPACE. POWER SUPPLY: PROVIDE TWO SEPARATE AND RELIABLE POWER SUPPLIES. THE CONTROL PANEL SHALL RECEIVE 120 VAC POWER VIA A DEDICATED FUSED DISCONNECT CIRCUIT OF THE BUILDING'S ELECTRICAL SYSTEM. EACH SHALL HAVE ADEQUATE CAPACITY FOR THE SYSTEM. THE FIRE ALARM CONTRACTOR SHALL SUBMIT BATTERY CALCULATIONS FOR REVIEW AND APPROVAL. THE CALCULATIONS SHALL INDICATE EACH DEVICE AND THE LOAD REQUIRED IN STAND -BY AND ALARM MODE. THE SECONDARY POWER SYSTEM SHALL BE A BATTERY - -OPERATED EMERGENCY POWER SUPPLY AND CHARGER WITH CAPACITY FOR OPERATING SYSTEM IN STANDBY MODE FOR 60 HOURS FOLLOWED BY ALARM MODE FOR 5 MINUTES. SYSTEM SUPERVISION: AUTOMATICALLY DETECTS AND REPORTS OPEN CIRCUITS, SHORTS, AND GROUNDS OF WIRING FOR INITIATING DEVICE, SIGNALING LINE, AND NOTIFICATION APPLIANCE CIRCUITS. ALARM, SUPERVISORY AND TROUBLE SIGNALS SHALL BE MONITORED BY THE SUPERVISING STATION OVER A DIGITAL ALARM COMMUNICATOR TRANSMITTER (DACT), OR OTHER APPROVED METHOD. INITIATING DEVICE CIRCUITS: PROVIDE CIRCUITRY, WHICH MEETS THE PERFORMANCE REQUIREMENTS DURING ABNORMAL CONDITIONS, BASED UPON THE STYLE AND CLASS OF THE CIRCUITRY SELECTED. INITIATING DEVICE CIRCUITS SHALL BE CLASS B, STYLE B. NOTIFICATION APPLIANCE CIRCUITS: PROVIDE CIRCUITRY, WHICH MEETS THE PERFORMANCE REQUIREMENTS DURING ABNORMAL CONDITIONS, BASED UPON THE STYLE AND CLASS OF THE CIRCUITRY SELECTED. NOTIFICATION APPLIANCE CIRCUITS SHALL BE CLASS B, STYLE Y. SIGNALING UNE CIRCUITS: PROVIDE CIRCUITRY, WHICH MEETS THE PERFORMANCE REQUIREMENTS DURING ABNORMAL CONDITIONS, BASED UPON THE STYLE AND CLASS OF THE CIRCUITRY SELECTED. SIGNALING LINE CIRCUITRY SHALL BE CLASS B, STYLE 4. AUXILIARY RELAYS: PROVIDE SUFFICIENT SPDT AUXILIARY RELAY CONTACTS TO PROVIDE ACCESSORY FUNCTIONS SPECIFIED. 16C 2 -3 SEQUENCE OF OPERATIONS THE SEQUENCE OF OPERATION SHALL MATCH THAT OF THE EXISTING LANDLORD'S SYSTEM OR MEET THE CRITERIA LISTED BELOW AT A MINIMUM. TROUBLE SEQUENCE OF OPERATION: SYSTEM OR CIRCUIT TROUBLE PLACES SYSTEM IN TROUBLE MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: 1) VISIBLE AND AUDIBLE TROUBLE ALARM INDICATED AT FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL (IF PROVIDED). 2) TROUBLE SIGNAL TRANSMITTED TO CENTRAL STATION. 3) MANUAL ACKNOWLEDGE FUNCTION AT FIRE ALARM CONTROL PANEL SILENCES AUDIBLE TROUBLE ALARM; VISIBLE ALARM 15 DISPLAYED UNTIL INITIATING FAILURE OR CIRCUIT TROUBLE IS CLEARED. SUPERVISORY SEQUENCE OF OPERATION: THE ACTIVATION OF ANY SPRINKLER VALVE TAMPER SWITCH OR DUCT - MOUNTED SMOKE DETECTOR PLACES SYSTEM IN SUPERVISORY MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS: 1) VISIBLE AND AUDIBLE SUPERVISORY ALARM INDICATED BY ADDRESS AT FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL (IF PROVIDED). 2) SUPERVISORY SIGNAL TRANSMITTED TO CENTRAL STATION. 3) DUCT - MOUNTED SMOKE DETECTORS SHALL SHUTDOWN THEIR RESPECTIVE UNIT UPON DETECTION OF SMOKE AND REMAIN DOWN UNTIL MANUALLY RESET. 4) MANUAL ACKNOWLEDGE FUNCTION AT FIRE ALARM CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL SILENCES AUDIBLE SUPERVISORY ALARM; VISIBLE ALARM 15 DISPLAYED UNTIL DEVICE IS RETURNED TO ITS NORMAL POSITION /SUPERVISORY CONDITION IS CLEARED. ALARM SEQUENCE OF OPERATION: ACTUATION OF AN ALARM INITIATING DEVICE PLACES SYSTEM IN ALARM MODE, WHICH CAUSES THE FOLLOWING SYSTEM OPERATIONS. 1) AUDIBLE NOTIFICATION APPLIANCES SHALL SOUND UNTIL SILENCED BY THE ALARM SILENCE SWITCH AT THE CONTROL PANEL. 2) ALL VISIBLE ALARM NOTIFICATION APPUANCES SHALL DISPLAY A CONTINUOUS SYNCHRONIZED PATTERN UNTIL RESET BY THE ALARM RESET SWITCH. 3) ALARM SIGNAL TRANSMITTED TO CENTRAL STATION. 4) ALL AIR - HANDLING SYSTEMS THAT ARE MONITORED SHALL SHUTDOWN AND REMAIN DOWN UNTIL THE FIRE ALARM CONTROL PANEL IS RESET. 5) THE ALARM LED SHALL FLASH ON THE CONTROL PANEL AND REMOTE ANNUNCIATOR PANEL UNTIL THE ALARM HAS BEEN ACKNOWLEDGED AT THE CONTROL PANEL /REMOTE ANNUNCIATOR PANEL. ONCE ACKNOWLEDGED, THIS SAME LED SHALL LATCH ON AND THE CUSTOM LABEL FOR THE ADDRESS IN ALARM SHALL BE DISPLAYED ON THE ALPHANUMERIC LCD READOUT. A SUBSEQUENT ALARM RECEIVED FROM ANOTHER ADDRESS AFTER ACKNOWLEDGED SHALL FLASH THE ALARM LED ON THE CONTROL PANEL SHOWING THE NEW ALARM INFORMATION. 6) A PULSING ALARM TONE SHALL OCCUR WITHIN THE CONTROL PANEL UNTIL ACKNOWLEDGED. 16C 2 -4 INITIATING DEVICES DUCT MOUNTED SMOKE DETECTOR: PHOTOELECTRIC DETECTOR ALONG WITH A STANDARD, RELAY OR ISOLATOR DETECTOR MOUNTING BASE. PROVIDE FOR VARIATIONS IN DUCT AIR VELOCITY BETWEEN 300 AND 4000 FEET PER MINUTE. PROTECT THE MEASURING CHAMBER FROM DAMAGE AND INSECTS. PROVIDE AN AIR EXHAUST TUBE AND AN AIR SAMPUNG INLET TUBE THAT EXTENDS INTO THE DUCT AIR STREAM UP TO TEN FEET. PROVIDE DRILLING TEMPLATES AND GASKETS TO FACILITATE LOCATING AND MOUNTING THE HOUSING. PROVIDE REMOTE ALARM LEDS AND REMOTE TEST STATIONS AS SHOWN ON THE PLANS. 16C 2 -5 NOTIFICATION APPLIANCES VISIBLE ALARM NOTIFICATION APPLIANCES (STROBES): STROBES SHALL BE XENON OR EQUIVALENT, UNFILTERED OR CLEAR FILTERED WHITE LIGHT, A MINIMUM INTENSITY OF 15/75 CANDELA AND AS INDICATED ON DRAWINGS, FLASH RATE RANGE FROM 1 TO 3 HZ, A MAXIMUM PULSE DURATION OF 0.2 SEC WITH A MAXIMUM DUTY CYCLE OF 40 %. STROBE SHALL MEET ALL REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (MINIMUM 75 CD AS TESTED PER UL 1971). AUDIBLE/VISIBLE ALARM NOTIFICATION APPLIANCES (HORN /STROBES): COMBINATION UNITS SHALL PROVIDE A COMMON ENCLOSURE FOR THE FIRE ALARM AUDIBLE AND VISIBLE ALARM APPUANCES AND BE UL LISTED FOR ITS PURPOSE. MINIMUM AUDIBLE LEVEL AND STROBE INTENSITY SHALL MEET ALL REQUIREMENTS FOR SEPARATE APPLIANCES. 16C 2 -6 AUXILIARY DEVICES CONTROL RELAY MODULE: PROVIDE INTELLIGENT CONTROL RELAY MODULES. THE CONTROL RELAY MODULE SHALL PROVIDE ONE FORM "C" DRY RELAY CONTACT RATED AT 2 AMPS CP 24 VDC TO CONTROL EXTERNAL APPLIANCES OR EQUIPMENT SHUTDOWN. THE CONTROL RELAY SHALL BE RATED FOR PILOT DUTY AND RELEASING SYSTEMS. THE POSITION OF THE RELAY CONTACT SHALL BE CONFIRMED BY THE SYSTEM FIRMWARE. 16C 2 -7 FIRE ALARM WIRE AND CABLE FIRE ALARM POWER BRANCH CIRCUITS: BUILDING WIRE AS SPECIFIED IN DIVISION 16. SIGNALING LINE, INITIATING DEVICE AND NOTIFICATION APPLIANCE CIRCUITS: POWER LIMITED FIRE- PROTECTIVE SIGNALING CABLE, SOLID COPPER CONDUCTOR, 300 VOLTS INSULATION, SUITABLE FOR TEMPERATURE, CONDITIONS AND LOCATION INSTALLED. MINIMUM WIRE SIZE FOR INITIATING DEVICE CIRCUITS, CONTROL CIRCUITS AND NOTIFICATION APPLIANCE CIRCUITS SHALL BE DETERMINED BY CALCULATIONS AND MANUFACTURER'S REQUIREMENTS OR RECOMMENDATIONS. WIRE AND CABLE SHALL BE TWISTED AND SHIELDED IF RECOMMENDED BY THE SYSTEM MANUFACTURER. INITIATING, NOTIFICATION, AND CONTROL CIRCUITS SHALL BE SIZED BASED ON 20% ADDITIONAL POWER CONSUMING DEVICES. THE CONDUCTORS SHALL MEET THE REQUIREMENTS OF NEC ARTICLE 760. THE TYPE OF CABLE CHOSEN SHOULD BE BASED ON FIRE ALARM SYSTEM REQUIREMENTS, SPECIFICATION REQUIREMENTS AND APPLICABLE CODE REQUIREMENTS. CONSIDERATION SHOULD ALSO BE GIVEN TO THE LENGTH OF CABLE RUNS AND POTENTIAL INTERFERENCE. ALL WIRING PROVIDED ON THIS PROJECT SHALL BE UL USTED FOR THE INTENDED USE. ALL WIRING INCLUDING WIRING TO EXISTING MODIFIED DEVICES AND APPLIANCES SHALL BE NEW. 16C 3 EXECUTION 16C 3 -1 GENERAL THE CONTRACTOR SHALL INSTALL, PROGRAM AND TEST ALL NEW EQUIPMENT IDENTIFIED IN THIS CONTRACT AND REVISE EXISTING EQUIPMENT AS NOTED. THE INSTALLATION SUPERVISOR SHALL BE ON THE JOB SITE DURING THE ENTIRE INSTALLATION. THE INSTALLATION SUPERVISOR SHALL MAINTAIN MARKED UP COPIES OF THE DRAWINGS AT THE JOB SITE SHOWING AS -BUILT CONDITIONS. THESE DRAWINGS SHALL BE UPDATED DAILY AND AVAILABLE FOR OWNER REVIEW. THE CONTRACTOR SHALL PROVIDE ALL REQUIRED CONDUIT AND ALL ASSOCIATED HARDWARE, AND SHALL INSTALL (PULL), CONNECT, AND TEST ALL CABLE FOR A COMPLETE FIRE ALARM SYSTEM. ALL WIRING SHALL BE INSTALLED IN ACCORDANCE WITH THE GUIDELINES OF THESE SPECIFICATIONS AND DOCUMENTS AS WELL AS THE NFPA CODES AND STANDARDS LISTED IN THESE SPECIFICATIONS. 16C 3 -2 INSTALLATION MINIMUM ALLOWABLE CONDUIT SIZE SHALL BE 3/4 INCH. THE CONDUIT SHALL BE SIZED SO THAT CONDUIT FILL DOES NOT EXCEED 75% OF NFPA 70 MAXIMUM FILL REQUIREMENTS. CABLES IN VERTICAL RISERS SHALL NOT EXCEED 50% OF NFPA 70 MAXIMUM FILL REQUIREMENTS. CONDUIT INSTALLATION SHALL BE AS REQUIRED BY THE CONTRACTOR'S LAYOUT AND AS DESCRIBED IN THESE SPECIFICATIONS. ALL CONDUIT FIELD ROUTING SHALL BE ACCEPTABLE TO THE OWNER. ROUTING NOT ACCEPTABLE SHALL BE REROUTED AND REPLACED WITHOUT EXPENSE TO THE OWNER. ALL WIRE, CABLE, CONDUIT AND RACEWAYS SHALL BE CONCEALED IN WALLS, CEILING SPACES, ELECTRICAL SHAFTS OR CLOSETS IN FINISHED AREAS EXCEPT AS SPECIFICALLY NOTED OTHERWISE. CONDUIT AND RACEWAYS MAY BE EXPOSED IN UNFINISHED AREAS OR WHERE SPECIFICALLY APPROVED BY THE OWNER. EXCEPT AS OTHERWISE SPECIFIED OR INDICATED ON THE DRAWINGS, ALL CONDUIT SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO DOMINANT SURFACES WITH RIGHT ANGLE TURNS MADE OF SYMMETRICAL BENDS OR FITTINGS. EXCEPT WHERE PREVENTED BY THE LOCATION OF OTHER WORK, A SINGLE CONDUIT OR A CONDUIT GROUP SHALL BE CENTERED ON STRUCTURAL MEMBERS. CONDUIT SHALL BE LOCATED AT LEAST SIX INCHES FROM HOT WATER OR STEAM PIPES, AND FROM OTHER HOT SURFACES. CONDUIT SHALL NOT BLOCK ACCESS TO ANY EXISTING EQUIPMENT OR FIXTURES. ALL CONDUITS AND JUNCTION BOXES SHALL BE LABELED AS SPECIFIED IN DIVISION 16 (RED). ALL WIRING SHALL BE TERMINATED AT DEVICES OR PANELS USING TERMINAL CONNECTORS FOR SCREW TYPE TERMINALS. ALL TERMINAL CONNECTORS FOR CONDUCTORS SHALL BE PRE - INSULATED RING TYPE OR PRE - INSULATED SPADE TYPE. PRE - INSULATED TERMINAL CONNECTORS SHALL INCLUDE A VINYL SLEEVE, COLOR CODED TO INDICATE CONDUCTOR SIZE. PRE - INSULATED TERMINAL CONNECTORS SHALL INCLUDE A METALLIC SUPPORT SLEEVE BONDED TO THE VINYL - INSULATING SLEEVE AND DESIGNED TO GRIP THE CONDUCTOR INSULATION. MOUNT END -OF- --LINE DEVICE IN BOX WITH LAST DEVICE OR SEPARATE BOX ADJACENT TO LAST DEVICE IN CIRCUIT FOR CONVENTIONAL HARDWIRED CLASS B INITIATING AND NOTIFICATION APPLIANCE CIRCUITS. CONDUIT SHALL BE SECURELY FASTENED TO ALL BOXES AND CABINETS. THREADS ON METALLIC CONDUIT SHALL PROJECT THROUGH THE WALL OF THE BOX TO ALLOW THE BUSHING TO BUTT AGAINST THE END OF THE CONDUIT. THE LOCKNUTS BOTH INSIDE AND OUTSIDE SHALL THEN BE TIGHTENED SUFFICIENTLY TO BOND THE CONDUIT SECURELY TO THE BOX. CONDUIT SHALL ENTER CABINETS FROM THE BOTTOM AND SIDES ONLY. INSTALL WALL MOUNTED VISIBLE AND AUDIBLE/VISIBLE NOTIFICATION APPUANCES WITH VISIBLE ELEMENT (STROBE) BETWEEN 80 INCHES AND 96 INCHES ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE ON DRAWINGS. INSTALL WALL MOUNTED AUDIBLE DEVICES WITH THE TOP OF THE DEVICE AT LEAST 90 INCHES ABOVE FINISHED FLOOR OR 6 INCHES BELOW THE CEILING, WHICHEVER IS LOWER, UNLESS NOTED OTHERWISE ON DRAWINGS. IF COMBINATION DEVICES ARE INSTALLED, THEY SHALL BE INSTALLED PER THE VISIBLE SIGNAL DEVICE REQUIREMENTS. MAKE CONDUIT AND WIRING CONNECTIONS TO EQUIPMENT PROVIDED BY OTHERS LISTED IN SECTION 1.1.E. PROVIDE STROBE SYNCHRONIZATION AS REQUIRED PER NFPA 72. 16C 3 -3 FIELD QUALITY CONTROL SYSTEMS SHALL BE CHECKED AND TESTED IN ACCORDANCE WITH THE INSTRUCTIONS PROVIDED BY THE MANUFACTURER TO INSURE THAT THE SYSTEM FUNCTIONS AS REQUIRED AND IS FREE OF GROUNDS, OPENS, AND SHORTS. EACH DEVICE SHALL BE TESTED. SMOKE DETECTORS SHALL BE TESTED WITH PRODUCTS OF COMBUSTION. UPON COMPLETION OF THE SYSTEM INSTALLATION AND BEFORE THE DATE OF FINAL ACCEPTANCE, A FACTORY - TRAINED TECHNICIAN SHALL PERFORM ALL NECESSARY TESTS AND ADJUSTMENTS AND SHALL THEN FILE A LEIIER OF CERTIFICATION AND A CERTIFICATE OF COMPLETION (NFPA 72) WITH THE OWNER INDICATING THAT THE SYSTEM FUNCTIONS AND CONFORMS TO THE FIRE ALARM SYSTEM SPECIFICATIONS. TEST IN ACCORDANCE WITH NFPA 72 AND LOCAL FIRE DEPARTMENT REQUIREMENTS. 16C 3 -4 MANUFACTURER'S FIELD SERVICES INCLUDE SERVICES OF FACTORY TRAINED AND CERTIFIED TECHNICIAN TO SUPERVISE INSTALLATION, ADJUSTMENTS, FINAL CONNECTIONS, AND SYSTEM TESTING AS PERFORMED BY THE FIRE ALARM CONTRACTOR'S FACTORY - TRAINED TECHNICIANS. THE EQUIPMENT SUPPLIER'S FACTORY TRAINED TECHNICIAN SHALL TRAIN THE OWNER'S PERSONNEL IN THE PROPER USE AND MAINTENANCE OF THE SYSTEM. TRAINING SESSIONS SHALL BE CONDUCTED AS NEEDED, NOT TO EXCEED A TOTAL OF 2 SESSIONS, WITH EACH SESSION LASTING A MAXIMUM OF 4 HOURS EACH. 16C 3 -5 ACCEPTANCE TESTING UPON COMPLETION OF THE SYSTEM INSTALLATION, A FACTORY - TRAINED TECHNICIAN SHALL PERFORM ALL NECESSARY TESTS AND ADJUSTMENTS IN THE PRESENCE OF THE OWNER'S DESIGNATED PERSONNEL. END OF SECTION 16C FEB - 8 2008 PERMIT GENIE REVIEWED �CE CODE NFPA 70 - NEC Ma 2 k 2BBB Of Tukwila TWIN . DWI TON HENDERSON ENGINEERS=_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 ra 713 7837707 FAX 713 783 7797 www.hei-eng.com 0750001294 RJS JMH SLM 4325 Tarn-O-Shanter Way, Dayton, OH 45429 j p 937.477233411nfo@moda4.com 555 Southcenter CO co CO 8 O Q W rti N U) co MODA4 PROJECT NUMBER: 07009 ISSUED/REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 FIRE ALARM SPECIFICATIONS E -4.1 2 3 4 5 6 7 8 9 10 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2006 Washhgton State Nanreslden5al Energy Code Compliance Forms LTG -INT Revised July 2007 Project Info Project Address GodJ.va Choco1atier - southcenter Mall Date 1/24/2008 633 Southcenter, Suite 1020 For Building Department Use Seattle, WA 98186 Applicant Name: Applicant Address: Applicant Phone: 967.5 Project Description ❑ Plans Included requirements. ❑ New Building ❑ Addition .1 Alteration Refer to WSEC Section 1513 for controls and commissioning 3, Compliance Option 0 Prescriptive ® Lighting Power Allowance Q Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting III- Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2.. Area in ft2 Allowed x Area Sales area 101 Retail Sales Area 1.50 645.0 967.5 Stockroom 102 Stockroom attached to main sales Floor 0.50 162.0 81.0 Restzgoa 103 Restrocm 0.80 56.0 44.8 root Table 15 -1 (over) - document all exceptions cm form LTG-LPA Proposed Lighting Wattage Total Mowed Watts 1093 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 Type 82 - Semi- Recessed Adjustable Fixture 6 40.0 240.0 101 Type SA - fi^ Square Adjustable Fixture 4 44.0 176.0 101 Type SD - 5" Square nownlight 2 44.0 88.0 101 Type PA - Pendant - Exempt per Table 15 -1, Footnote 10 8 1.5 Exercise center 101 Type 82A - semi- Recessed Adjustable Fixture 2 44.0 88.0 102 Type SR - 4+ Linear Channel Fixture 5 58.0 290.0 103 Type FC - Fan /Light combo 1 60.0 60.0 101 Type B2 - Ex apt per 1512.1 - Food Prep ATOa 4 0.5 Hotel banquet /conference /exhibition ha113° 101 Type 82 -- Exempt per Table 15 -1, Footnote l0 4 Laboratory spaces (all spaces not classified 'laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 No exterior ltg Libraries' 1.3 Plans Submitted for Common Areas Only` Indicate location oral Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 942.0 Notes: 1. For proposed Fixture Description, indicate fixture type, Tamp type (e.g. T -8), number of tamps in the fixture, and ballast type (if Included). For trade lighting, fist the length of the trade (In feet) in addition to the fixture, lamp. and ballast information_ 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track tighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) 2006 Washington State Nonresidential Energy Code coepIance Forms LTG -INT Revised July 2007 Prescriptive Spaces Qualification Checklist Note: If occupancy type is - Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans- If not qualified, do LPA Calculations. Occupancy: Warehouses, storage areas or aircraft storage hangers Lighting Fixtures: (Section 1521) 0 other Check If 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 .60 watt T -1, T -2, T-1, T -5, T-8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2- Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED fights. TABLE 15-1 Unit Lighting Power Allowance (LP Use' 1 LPA{ (Wisf) Use' LPA` (W(sf) Automotive facility 0.9 on buildings, office /administrative areas in facilities of other use types (including but not limited to schools. hospitals, institutions. museums. banks, churches)57•" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias. fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail1', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1-1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses'", storage areas 0.5 Hotel banquet /conference /exhibition ha113° 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified 'laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 No exterior ltg Libraries' 1.3 Plans Submitted for Common Areas Only` Indicate location Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 ootnotes for Table 1) In cases in which a general use and a specific use are fisted, the specific use shall apply. In cases in which a use is not mentioned specifically. the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified In the table. See Section 1512 for exempt areas_ 2) The watts per square foot may be increased, by two percent; per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150f9 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2- 10) Display window illumination Installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three-quarter- height partitions (transparent or opaque). and Iighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). 0) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge [amps. This additional fighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, Indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary 2006 Washington State Nonresidential Snergy Code Compare= Forms Revised July 2007 Project Info Proj Addresicodi_va cbocolatier - southcenter tda11 Date 1/24/2008 633 southcenter, Suite 1020 For Building Department Use 6eattla, WA 98186 Name: Appl. Name Appl. Phone Project Description yes New ❑ Addition ❑ Alteration • Pleas Included Indicate controls (Sections 1513) Including commissioning requirements on plans. Compliance Option © Lighting Power Allowance 0 systems Analysis l3uilding Grounds (luminaires > 100 Watts) motion Sensor • Efficacy > 60 lumens/W ❑ Controlled by 12 Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132 3) ❑ No changes are being made to the fighting • Less than 60° of the fixtures new. installed wattage not increased, & space use not changed. Tradable Maximum Allowed Li tin Wattage Tradable Locations Description Allowed Watts per ft2 r per If Area (ft2), perimeter Of) or # of items Allowed Wafts x if (or x It) Applicability (yes, no, n.a.) i Code Section I Location I Component 'Information Required on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch Tradable Proposed Lighting Wattage Total Mowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Applicability (yes, no, n.a.) i Code Section I Location I Component 'Information Required on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts Non - Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or# of items Allowed Watts x ft2 (or x if) Applicability (yes, no, n.a.) i Code Section I Location I Component 'Information Required on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch Non - Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Applicability (yes, no, n.a.) i Code Section I Location I Component 'Information Required on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch Proposed Watts may not exceed Allowed Watts for Category 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Motor, and Transformer Permit Plans Checklist;:::.: LTG -CHK 2008 Washington State Nonresidential Energy Code Compliance Foams .... Revised July 2007 Project Address Codi.va Chocolatier - seu*snentex Mall Date 1/24/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements In the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) i Code Section I Location I Component 'Information Required on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch E -2.0 no 1513.3 Daylight zone control Schedule with type and features, Indicate locations no vertical glazing Indicate vertical glazing on plans No daylignting no overhead glazing Indicate overhead glazing on plans No overhead glazing yes 1513.4 Display /exhfo /special indicate separate controls E -2.0 1613.5 Exterior shut-off with type and features, indicate location no eer Indicate No exterior ltg no (b) photocell. Indicate location No exterior ltg 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations Controlled by contactor and switches yam 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E -2 -0 Contactor C. no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign E -1.0 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior lighting Summary Form Completed and attached. Schedule with fixture types, lamps, hailasts, watts per fixture Attached no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture No exterior ltg MOTORS (Section 1511) no 1511 Elec motor efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency No motors over 1 TRANSFORMERS (Section 1540) yes 1540 Transformers Indlcate size and efficiency E- 2.1,E•TF1 4.0 If "no" is circled for any question, provide explanation: RECERIP FEB - 8 2008 PERMIT CENT. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR 2 6 naa Qty Of Tukwila ILDDNG DIVISION HENDERSON ENGiNEERS =_ 10370 RICHMOND AVENUE, SUITE 370 HOUSTON, TX 77042 TEL 713 783 7707 FAX 713 783 7797 www.hei- eng.com 0750001294 RJS JMH SLM 4325 Tam- OShanter Way, Dayton, OH 454291 p 937.477.23341 Info@moda4.00m /08 e TENANT FIT OUT AT MODA4 PROJECT NUMBER: 07009 ISSUED / REVISED DATE HEALTH DEPT SUBMITTAL 12.17.07 98% OWNER REVIEW 01.03.08 HEALTH DEPT RVSNS 01.11.08 ISSUED FOR PERMIT 01.25.08 ELECTRICAL ENERGY FORMS E -5.0