Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-1295 - STARFIRE SPORTS
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL08 -1295 Starfire Sports 14800 Starfire Way RECORDS DIGITAL D- ) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # tode Exemption = 8rlef Explanatory DeSclriptiop �t�tutel ule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals' social security Personal Information — numbers are redacted to protect those Social Security Numbers individuals' privacy pursuant to 5 U.S.C. sec. 5 U.S.C. sec. DR1 Generally — 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW 552(a); RCW under section 42.56.070(1) of the Washington 42.56.070(1) 42.56.070(1) State Public Records Act, which exempts under the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information — expiration dates, or bank or other financial RCW 19 DR2 Financial Information — account numbers, which are exempt from 42.56.230(5) RCW 42.56.230(4 5) disclosure pursuant to RCW 42.56.230(5), except when disclosure is expressly required by or governed by other law. STARFIRE SPORTS 14800 STARFIRE WI' ELO8- 1295 CitAlaf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2323049001 Address: 14800 STARFIRE WY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1295 Issue Date: 10/07/2008 Permit Expires On: 04/05/2009 Tenant: Name: STARFIRE SPORTS Address: 14800 STARFIRE WAY , TUKWILA WA Owner: Name: TUKWILA CITY OF Phone: Address: 6200 SOUTHCENTER BLVD , TUKWILA WA Contact Person: Name: BROOK BOONE Phone: 253 - 261 -5768 Address: 31632 102 AVE SE , AUBURN WA Contractor: Name: DUCHESS CONSTRUCTION INC Phone: 253 952 -7285 Address: P.O. BOX 1985 , MILTON Contractor License No: DUCHECI021N8 Expiration Date: 09/01/2010 DESCRIPTION OF WORK: 400 AMP 480 VOLT SERVICE, 8 LIGHT POLES Value of Electrical: 147,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Lo:dt Fees Collected: National Electrical Code Edition: $2,582.50 2005 Date: ID` 7-0 v I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o pof ork. I am authorized to sign and obtain this electrical permit. 1 performance Signature: 760/Z. CO Date: Print Name: (:,6(66/4 boG This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1295 Printed: 10 -07 -2008 Parcel No.: 2323049001 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 14800 STARFIRE WY TURIN STARFIRE SPORTS PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1295 ISSUED 09/30/2008 10/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature:?( / Egin f Print Name: 'BOO /L FC-)0 h 41 doc: Cond -Elec EL08 -1295 Printed: 10 -07 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. L.O C- 1 Project No. 1208- oqg (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION P-1900 900 Sl -eAv- 1 e Cc) t f Site Address r Tenant Name: .5 4tyt-c;rp __ j p r-I-S Property Owners Name: 5- 1 (C, Fe,•. SPoi -i• z) /1.4 Wert 7740.4i i l c. k City King Co Assessor's Tax No.: Suite Number: 23z SQL - '1001 New Tenant: Mailing Address: Floor: ❑ Yes ❑..No State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name:r3(6-6 /C gCeS h A Mailing Address: 33/412— /r•2-,, 1 �w fE /J'!% ��7 y�%C1 fed 42—__ City State Zip Day Telephone:Z53 — Ztv f —5 74-6) E -Mail Address: Dale—/r4.2.— 1/19/ e43/01 Fax Number: 45-3 8C3— S/4 S ELECTRICAL CONTRACTOR INFORMATION Company Name: PvGLe s 5 Ge A. -4- as J e ti Z'.� Mailing Address: Pp b, s- /S8 mi WA Contact Person:2(ba /C goo r� E -Mail Address:1360/re /,G7 e2— Contractor Registration Number: Di /Gin e,r y o' I n P8 3sy City State Zip Day Telephone:45j— Z. ( — 5X Fax Number: Zrf e4)—W‘ e Expiration Date: tL° Valuation of Project (contractor's bid price): $ / Y .2/ GO Scope of Work (please provide detailed information): `100 Arr j2 %/BD i'6/4 SeI'v/e� s 1. L 4- pc, te5 Will service be altered? ❑ Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: Eij New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: j. Puget Sound Energy ❑ Seattle City Light H:ApplicationsWonns- Applications On Line 4 -2007 - Electrical Permit Applicaaon.doc bh Page 1 of 2 • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no addedialtered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits ..... . ... $10 00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential). $58.00 ❑ Temporary service (generator) S75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: gro /G god n-t� Print Name: t? coo ,1 Rod A Mailing Address: Po 60 -4 /985' Al Date: V2. Vei $ Day Telephone: 25-?- ICI— 5" g 1,1 seas/ City State Zip Date Application Accepted: 9-30 -o0 Date Application Expires: " 30_ D / Staff lnitials: H, Applicanons1Fonns- Applictuons On Gne14•2007 - Electrical Permit Application doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2323049001 Address: 14800 STARFIRE WY TUKW Suite No: Applicant: STARFIRE SPORTS RECEIPT Permit Number: EL08 -1295 Status: PENDING Applied Date: 09/30/2008 Issue Date: Receipt No.: R08 -03403 Payment Amount: $2,582.50 Initials: WER Payment Date: 09/30/2008 03:36 PM User ID: 1655 Balance: $0.00 Payee: STARFIRE SPORTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10099 2,582.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 2,066.00 516.50 Total: $2,582.50 doc: Receiot -06 Printed: 09 -30 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 - 6 Project: .e- Type of Inspection: /Dc \ 1 �J Address: DO 5 FiQ- Date Called: -- —. Special Instructions: Date Wanted: of / Q, L °.. p.m. Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: &riff Co►1heft Inspector: Ateil ri $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: D1 ©3 /07 Receipt No.: 'Date: psi- �,�.��au�� - �--y.. __,�.._.._...�,'E•"�! INSPECTION RECORD ���_'29�) Retain a copy with permit II INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: nO� Wt, Type of Inspection: 2,Op Addres : �L1 A� ` %�Yr QL �G Date Called: --. Special I' struction�s: 1 Date Wanted: 0� / a.m. Requester: q Phone No: Ai EjApproved per applicable codes. Corrections required prior to approval. COMMENTS: ..• 13 . • — t'ILI4,, it ? A A , i 4 ti 14 t 5 (ott &Jp or in-12-I107 Ai R-41)041 145r4i4. o DDiAA u , 4-r, Ad, 6P0 Wit, Inspector: .fir l��_ REINS�ECT N FEE 60 00 10 EE Date: B;(.JZ0 /0 ri $ QUIRED. Prior to inspection, fee n st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 7 INSPECTION NO. INSPECTION RECORD �`G�'64 �� Retain a copy with permit Imo' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IZ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: s Trsi{f /AA .sia ri % . Type of Inspectio ,lrO l Address: '� C Iq/it/�/w,/:h Date Called: Special Instructions: � N 1 Date Wanted: / f 2 %/ ,� � • a.m. • Requester: Phone No: oved per applicable codes. Corrections required prior to approval. /2fr COMMENTS: ,(f 7i ' E,f / v Insp r: Date: EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: -� - Abr., ......_... �.�_�.. . INSPECTION RECORD ! (�q Retain a copy with permit C--Q INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ig• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 Project: 5i1 Type of Inspection: ��� ,) Address : ,,r 1 OD 5001 Date Called: Special Instructions: Date Wanted: a.m. 17,/05- Cfm Requester: � Phone No: tApproved per applicable codes. Corrections required prior to approval. COMMENTS: OK. - 6.16-1c‘at ,5 Eic c.6 Inspector:. �'� . l J Date: r2/10E; /b� t 1 $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit f ? 1zk5 PERMIT NO. Project:T la 90 R Type of Inspection: !Vv 7oot Address: / l`�OO S i WI . Date Called: - toAlovir5 cRoi, stotccPki> TD poL S 7 Special Instructions: Date Wanted: /0/30 /-� �a`r�,, p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: O.K. - S -JMa L f 1 f/ /i r TO 17A-D. - toAlovir5 cRoi, stotccPki> TD poL S 7 Inspector: 111 6tntNit Date: / 0 / 30/ft El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit fiL £to`S 129 PERMIT NO. (206)431 -3670 Project: 10 eT � Type of Inspection: 7001 0,K . - u ,,J 9 AR..„ 0n19 CoA tf IT Address. c + Date Called: -To Po LE S r1 4f Special Instructions: , , j Date Wanted: J . .m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 12fir 0,K . - u ,,J 9 AR..„ 0n19 CoA tf IT li)t Pot.e$ 53 A4D 5 - ("4941-r) kT S (RJl C Ip -To Po LE S - 6a0J49 RODS a-r s htt,f Pi, Inspector &Aid /r� Date: 1 o Pfl El $60.00 REINSPECTION FE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit /)L 6,4 -12- PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: rk k Spp ssirvi Type of Inspection: 1"/ v Address j - mn 5- l n K � • Date Called: 55- ro 54 Special Instructions: Date Wanted: / D Zb a:m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?A- 2K. — OAJD CAQ.6 %>0 COAJ Wir9 SerLd664 Fl g49tk)Le5 1701-65 SL -ro 53 55- ro 54 Inspector: 6644e1\ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 10/2Y 0 Receipt No.: 'Date: _ ,s..._ .,an- .._a_e.:•S_e..w.70.: --...a.v,.�_�..._S.. a,...s . 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit £td -/z /sfi PERMIT NO. (206)431 -3670 Project: ,,- ri Ftkt 5 A zi-5 of Inspection: fool Address: r t r {A/ �/7 STARrie(61 • Date Called: r Special Instructions: Date Wanted: to/22_ a.m. m. Requester: Phone No: IDApproved per applicable codes. Corrections required prior to approval. COMMENTS: Pa �. - vnmt-(&(t..o' JO CDnJ DVrr5 C4o1 MA-ilC atilt-f>114(,� T1-1-kcu1. 4 Mao Le- 11) PoL4 5 Inspector: Orwex, El $60.00 REINSPECTION FEE REdUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaIL to schedule reinspection. Date: ' 0/27,-M Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit EA-121r PERMIT NO. (206)431 -36V0 Project: „ Ft %LT, Type of Inspection: 7001 Address: 1 taw ' m4f t ilk uJ'i • Date Called: Special Instructions: Date Wanted: /OM (a..m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: PA/ Gl K. - G0n1D t 11-5 I- 0 L-t 57 Inspector: Date: / /� 3 Dg $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: .� f 5f 0Q.T) Type of Inspection: ` 7 ' I Address.: Date Called: - et eau "f o O8l' A-J1c & to L An R.0 / _,5 Special Instructions: Date Wanted: r cD/C a:m: Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. /8 COMMENTS: C74 ' IN D V'(6,4 J Z)r 1" PVc. 4otT1 5Ipt 161,D IL Porch 31 A-4D 511 - et eau "f o O8l' A-J1c & to L An R.0 / _,5 Inspector: Date: /0/44 D $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: MU- "EMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1295 PROJECT NAME: STARFIRE SPORTS SITE ADDRESS: 14800 STARFIRE WAY X Original Plan Submittal Response to Incomplete Letter # DATE: 09 -30 -08 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: / -3-05 Buil lr Di Ision ► _i, Fire Prevention Public Works ❑ Structural n Planning Division Permit Coordinator DETERMINATION OF OMPLETENESS: (Tues., Thurs.) DUE DATE: 10-02 -08 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS R UTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10-30-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • • Page 1 of 1 Electrical Contractor A business licensed by L&I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company DUCHESS CONSTRUCTION INC 2538912016 PO BOX 1985 MILTON WA 98354 PIERCE CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601805583 ACTIVE DUCHECI021 N8 ELECTRICAL CONTRACTOR 8/28/1998 9/1/2010 BOONEJD250L5 GENERAL UNUSED ADMINISTRATOR INFORMATION License BOONEJD250L5 Name BOONE, JACK D Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date LEENSTRA, RUTH AGENT 08/28/1998 Received Date LEENSTRA, RUTH TREASURER 01/01/1980 Until Released BOONE, BROOK VICE PRESIDENT 01/01/1980 Assignment of Savings Information Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 1 08/27/1998 Until Released Bond $4,000.00 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= DUCHECI021 N8 10/07/2008 CIO 0 co 0 a_ J: \B1 5027 \CADDO5 \E10.DWG / ..• ,./. • • r / / / i ; .■ /'SHED • 4// / / 1/ 2uCSPARE 1.5"C'—SPARE „--- ,-- „4------ , , ,,,,,, _4-2 2"C—(3)#4,(1)/f6GND 2"C—SPARE MINN IMMIX arl.Thri 2.1:5 H!,? FI ,j i ! I , I 1 , , • • FIELD #12 7 ELECTRICAL SITE PLAN SCALE: AS INDICATED n 2"C—(3)#8,(1)#10GN 1■• 0 30 as indicated Fr IMMITIII■FM11111111111111•1 60 90 feet / • , FIELD #11 IMAM - =MME111■1111•111•1111M1 - „.. —IN - ompv-14.14,- AlgiAVORI _..7t62----7 i • / • . / (;1) , 2.5»C—(3)#4 (POLE1 S2), 2)#6 (ovERruo PARKING :LIGHTS) 2)#8 (AREA LIGHTS) !I 1)#6 GND r, (r) 0 LEGEND STEEL FLOODLIGHTING STANDARD SEPARATE PERMIT REQUIRED FOR: 0 teMethanical jlectrical Numbing Aets Piping City of Tukwila BUILDING DIVISION t> SHIELDED FLOODLIGHT, 1500 WATT, REMOTE BALLAST, 480 VOLT II AREA LUMINAIRE, 400 WATT MH, 480 VOLT E1.0 E1.1 NEMA 14-50R DUPLEX GFI RECEPTACLE, 120/240V, 50A, 4-1WIRE WITH WP COVER NEMA 3R 60 AMP FUSED DISCONNECT POLE AND FLOODLIGHT SCHEDULE POLE LENGTH TOTAL S1 90' 9 S2 90' 9 S3 90 14 S4 90' 9/10 S5 70' 4 S6 70' 4 57 70' 9/2 S8 70' 5 TOTAL 75 SHEET FLAG NOTES CONNECT EXISTING 480 VOLT PANEL STUB UP SPARE CONDUITS INSIDE BUILDING FILE COPY Permit No Rat- review approval is subject to errors and om!ssions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt �( approved Field Copy and conditions is acknowledged: By r9 /-p- Date: City of Tukwila BUILDING DIVISION R ONS No changes shall be made to the scope - of work without prior approval of Tukwila Building DiV151011• NOTE: Revisions will require a new plan submittal and may include additional plan review fees. EL() 8 ft 1 RECEIVED SEP 3020 PERMIT CENTER ; c:e (f) WORK TOGETHER I STAND APART (n z (n0 . 6.3 F... < 0 03 0 -Kt- 1 U) DRAWN: WMW LA th CHECKED: CBF 6.3 F... < 0 03 0 -Kt- 1 U) DRAWN: WMW 0 1 0 w o LL QC/) W o 2 O z col u) 0- w • Fo 0_ w ct Li_ !- Et 0 < w C.") W uJ z 0 STARFIRE SPORTS SHEET: E1.0 E1.0 ' E1.1 __2X- (3) #4,(146GND - - - - - 2 "C -SPARE 2 "C -SPARE 1.5 "C -SPARE N ' IMINIIII FIELD #12 2 "C- 3 #6, (2) #8,(1) #$GND r "C- 3 #4, 1) #6GND 2"c-0461048 0 wic FIELD ;#9 (2)4 "C (6)350MCM,(1)350MCM GILD r'�I t) -PEDESTAL PANEL - 2 "CS �?)3 "C -SPARE ':.1.5 "C -SPARE PARE is ELECTRICAL SITE PLAN SCALE: ASS INDICATED AA,A AAA A A PSE PADMOUNT TRANSFORMER , - 2.5 "C= 3 #2 POLE 32) (3 #2_ (POLE --S3 =FIELD _ #11 ) (3 #2 (P011 S3 /S8 FIELD #10) 3 #4 OVERFLOW PARKINC),LIG 2 #8 AREA LIGHTS) 3 #4 PARKING LIGHTS 1#4 GND 2.5"C-(342 (POLE POLE S1) (3) #2 (POLE S4 /S7 FIELD #9) (3) #2 (S4 /S7 FIELD #10) (3) #1 RECEPTACLE (POLE S7) (1) #2 GND 1.5 "C -SPARE HELD #11 HELD #10 (P41� S2) OVERFLOW,'PARKING L1GH;TS (AREA LIGHTS) _CND. , __h_ E1.0 El .1 S3 POLE 32) POLE S3 -FIELD #11) POLE S3 /S8 FIELD #10). (OVERFLOW PARKING LIGHTS) (AREA LIGHTS) GND 0 liffiffiwormniimmot as indicated 30 60 90 feet LEGEND 0 STEEL FLOODLIGHTING STANDARD © SHIELDED FLOODLIGHT, 1500 WATT, REMOTE BALLAST, 480 VOLT 1 AREA LUMINAIRE, 400 WATT MH, 480 VOLT NEMA 18 -50R DUPLEX CFI RECEPTACLE, 120/208V, 50A, 4 -WIRE WITH WP COVER SHEET FLAG NOTES: PSE TO INTERCEPT EXISTING UNDERGROUND PRIMARY AND SET NEW VAULT. COORDINATE WITH PSE. POLE AND FLOODLIGHT SCHEDULE POLE •a LENGTH TOTAL S1 .?, 90' 9 S2 90' 9 S3 90' 14 S4 90' 9/10 S5 70' 4 S6 70' 4 S7 70' 9/2 S8 70' 5 TOTAL 75 2.5"C-(32 () #2 (POLE S3 FIELD #11) (342 (POLE (3) #4 (OVERFLOW PARKING #L GF (2) #4(AREA PARKING LIGHTS) (1) #4 GND 101011E. VOR E 00 O` VII CtiorWsta `11 BOIL RECEIVED Y SEP` 3 02000 PERMIT CENTER U z REVISIONS CHECKED: CBF W CO 0 . DRAWN: WMW <C 1 0 10 w STARFIRE SPORTS - SOCCER FIELD LIGHTING 0 0 (1) 2 Z 0 W 0) J 0 i�- 0 LU cr w 0 STARFIRE SPORTS SHEET: E1.1 FLOODLIGHTS AND BRACKETS GALVANIZED STEEL POLE AREA LIGHTS. LIGHTS SHALL NOT BE MORE THAN 40FT ABOVE GRADE REMOTE BALLAST ENCLOSURE UNDERGROUND JUNCTION BOX, INSTALL ON 6" FREE DRAINING GRAVEL BY: WWARD 2 a 0 0 APR 29, 20Q8 - c.� 0 N W 0 0 0 r N 0 SLOPE TO DRAIN \-2" CONDUIT CONCRETE 3000 PSI MIN. PRECAST CONCRETE FOUNDATION, 18" DIA., MUSCO LIGHT STRUCTURE 2 METERING AND CT SECTION PER UTILITY REQUIRMENTS ro. 70' 80' 13' 30" MIN. STEEL POLE DETAIL E� SCALE: NONE 6" TYPICAL EACH SIDE t 24" INCOMING CONDUITS7 9 • I 14 A 277/480V 3 PH 4W 400A Main CB Type: Panelboard Pedestal Panel Surface Mounted 30,000 AIC Sin • le Lugs Panel CONTROLLER LIGHTING CB * I PANEL B © Load CONTROL PANEL LCP PANEL A MIN EMI 3 BM ■ ❑ ❑ • LIGHTING CONTACTORS 6.80 40 3 CB OM 45KVA XFMR 6.80 Lighting Pole S3, S8 _ Field ; 10 14 92.0 PHOTOCELL. PROVIDE EXPANDED METAL COVER GASKETED ND SCREENED TENT TOP & BOTTOM e 2/0 BARE COPPER OUTGOING CONDUITS FRONT PEDESTAL PANEL DETAIL E 2 0 SCALE: NONE x6 "- 10 /10WWF 3/4 X IO' GROUND ROD AT EACH CORNER ONE -LINE DIAGRAM SCALE: NONE 1-4-- 30" 90 3" 11 SIDE CONCRETE 3000 PSI MIN. " - 10/10 WWF SHEET FLAG NOTES SUPPLIER OF GALVANIZED STEEL POLE TO PROVIDE STRUCTURAL CALCULATIONS FROM A LICENSED STRUCTURAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON. CALCULATION TO INCLUDE WIND AND SEISMIC LOADS PER IBC 2003. SUBMIT WITH MANUFACTURER SHOP DRAWINGS DURING SUBMITTAL PHASE OF THE PROJECT. CONTRACTOR TO PROVIDE FOUNDATION AND STRUCTURAL CALCULATIONS FROM A STRUCTURAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. CALCULATION TO INCLUDE WIND AND SEISMIC LOADS PER IBC 2003. SUBMIT WITH MANUFACTURER SHOP DRAWINGS DURING SUBMITTAL PHASE OF THE PROJECT. CONTRACTOR TO REFER TO SOILS REPORT IN PROJECT MANUAL TO ASSESS CONDITIONS AFFECTING DRILLING FOR INSTALLATION OF POLE FOUNDATIONS, ALTERNATE FOUNDATION DESIGN ALLOWED. PROVIDE MOW STRIP AT TOP OF FOUNDATION. SMOOTH FINISH CONCRETE AND SET AT GRADE. CONDUIT RISER SHALL BE INSTALLED FLUSH TO POLE PRIOR TO POURING CONCRETE. Sparling Name Location: Serves: A 277/480V 3 PH 4W 400A Main CB Type: Panelboard Pedestal Panel Surface Mounted 30,000 AIC Sin • le Lugs Panel 45KVA 480V-208Y/120V 30 4W Load CB * I CB © Load CONTROL PANEL LCP PANEL 120/208V 125A MCB MIN EMI 3 BM PANEL I EI 277/480V 400A M B 6.80 40 3 CB OM 40 3 CB 6.80 Lighting Pole S3, S8 _ Field ; 10 2 -Pole S1 6.80 11111=1111 X 92.0 PHOTOCELL. PROVIDE EXPANDED METAL COVER GASKETED ND SCREENED TENT TOP & BOTTOM e 2/0 BARE COPPER OUTGOING CONDUITS FRONT PEDESTAL PANEL DETAIL E 2 0 SCALE: NONE x6 "- 10 /10WWF 3/4 X IO' GROUND ROD AT EACH CORNER ONE -LINE DIAGRAM SCALE: NONE 1-4-- 30" 90 3" 11 SIDE CONCRETE 3000 PSI MIN. " - 10/10 WWF SHEET FLAG NOTES SUPPLIER OF GALVANIZED STEEL POLE TO PROVIDE STRUCTURAL CALCULATIONS FROM A LICENSED STRUCTURAL ENGINEER REGISTERED IN THE STATE OF WASHINGTON. CALCULATION TO INCLUDE WIND AND SEISMIC LOADS PER IBC 2003. SUBMIT WITH MANUFACTURER SHOP DRAWINGS DURING SUBMITTAL PHASE OF THE PROJECT. CONTRACTOR TO PROVIDE FOUNDATION AND STRUCTURAL CALCULATIONS FROM A STRUCTURAL ENGINEER LICENSED IN THE STATE OF WASHINGTON. CALCULATION TO INCLUDE WIND AND SEISMIC LOADS PER IBC 2003. SUBMIT WITH MANUFACTURER SHOP DRAWINGS DURING SUBMITTAL PHASE OF THE PROJECT. CONTRACTOR TO REFER TO SOILS REPORT IN PROJECT MANUAL TO ASSESS CONDITIONS AFFECTING DRILLING FOR INSTALLATION OF POLE FOUNDATIONS, ALTERNATE FOUNDATION DESIGN ALLOWED. PROVIDE MOW STRIP AT TOP OF FOUNDATION. SMOOTH FINISH CONCRETE AND SET AT GRADE. CONDUIT RISER SHALL BE INSTALLED FLUSH TO POLE PRIOR TO POURING CONCRETE. Sparling Name Location: Serves: A 277/480V 3 PH 4W 400A Main CB Type: Panelboard Pedestal Panel Surface Mounted 30,000 AIC Sin • le Lugs Panel Description Load CB * A B CB © Load Description i MIN EMI 3 BM L.htin• Pole S1 6.80 40 3 CB OM 40 3 CB 6.80 Lighting Pole S3, S8 _ Field ; 10 2 -Pole S1 6.80 11111=1111 X - -__ -_ T_ -� 6.80 Pole 53, 58 - Field ; 10 4 Pole 51 6.80 -. - -- 6 7 6,80 -- -Pole S3, S8 - Field ; 10 6 Li•htin• Pole S2 6.80 40 3 CB X inn= 40 3 CB 6.80 6,80 Lighting Pole S4, S7 - Field ; 10 Pole S4, S7 - Field ; 10 8 10 9 Pole S2 6.80 - _ -_ - -_ 11 -- Pole S2 6.80 Space X 0 1 6.80 -Pole S4, S7 - Field #10 12 13 Li • htin • Pole S3 -- Field 11 6.80 6.80 40 3 CB BM 40 3 CB 6.80 6,80 Lighting Pole S4, S7 - Field ; 9 14 - -Pole S4, S7 - Field ; 9 16 15 Pole S3 - Field #11 17 Pole S3 - Field ; 11 6.80 0 1 X - -- 6.80 -Pole S4, S7 - Field ; 9 18 19 Li•htin• Pole S3 - Field ; 10 6.80 40 3 CB X 40 3 CB 6.80 Li•htinp Pole S5, S6 - Field9 20 0.00 -Pole S3 -- Field ; 10 6.80 0 1 0.00 -- 6.80 Pole S5, S6 - Field ; 9 22 23 - -W-Pole S3 - Field #10 6.80 - - -- - -- X „, 6,80 Pole S5, S6 Field 9 24 25 29 Li. htin • Parkin • Lights --• Parkin • Li • hts Parkin• Li•hts 0.80 0.80 0.80 30 3 CB - ---- X X 30 3 CB 0.67 0.67 0.67 Li • htin • Overflow Lights - Overflow Li • hts 26 28 30 Overflow Lights 31 Lighting Area Lights 0.67 20/3 CB Connected KVA 60/3 CB 1.20 Li•htin• Maintenance Buildin• 32 33 Area Lights 0.67 --- Equip 0.50 x 100% 0.50 1 x 100% Recept 3.20 10 KVA © 100 %, rest 0 50% 3.20 9 x 100% 9 3.70 10 Amps 3.70 10 10 ___ - - -- 1.20 -- Maintenance Building 34 36 35 Area Lights 0.67 -- ----- 1.20 -- Maintenance Buildin+ 37 Lighting Overflow Parking Lights 1.00 30/3 X 0/3 1.20 Panel B 38 39 �-Overflow Rev: Revised 815027 File: - _ -__.� ._Overflow Parking Lights 1.00 X - -_ 1.50 -8 40 Parkin. Lights 1.00 X , 1.00 B 42 Ckts Marked * Existing Ckts Marked # J: \615027 \design \sched \Panel A Musco PH A PH B PH C * Circuit Breaker Code Connected KVA 59.93 60.23 59.73 G = GFCI H = HID Rated PNL S = Shunt Trip C. = HACR Rated D = Switching Duty # = See Note A = AFCI Notes: Load Type Conn KVA NEC Demand Factor Dem. KVA Dem. Amps NEC Feed % NEC Feed Amps Equip 0.50 x 100% 0.50 1 x 100% 1 Lighting 176.20 x 100% 176.20 212 x 125% 265 Recept 3.20 10 KVA © 100 %, rest 0 50% 3.20 4 x 100% 4 179.90 216 Amps 179.90 216 269 Sparling Name B 120/208V 3 P11 4W 125A Main CB Type: Panelboard Location: Pedestal Panel Surface Mounted 10,000 AIC Serves: Single Luis Panel Description Load CB * A B C CB Load Description • 1 Rece•t NEMA 18-50R, Pole S7 1.00 50 3 CB Mill 20 1 CB 0.20 Recept Pedestal 2 3 5 --- --- - -- NEMA 18 -50R, Pole S7 - -. - - -- -NEMA 18 -50R, Pole S7 1.00 1.00 emilIMER X 20 1 CB 20 1 CB 0.50 0.00 E• ui. Li • htin • Controller 4 Spare 6 7 Space 0.00 0 1 20 1 CB 0.00 Spare 8 9 S•ace 0.00 0 1 X 0 1 0.00 Space 10 11 Space 0.00 0 1 ® 0 1 0.00 Space 12 13 Space 0.00 0/1 0/1 0.00 Space 14 15 Space 0.00 0 1 0 1 0.00 Space 16 17 Space 0.00 0 1 X 0 1 0.00 S•ace 18 19 Space 0.00 0 1 X 0 1 0.00 S.ace 20 21 S•ace 0.00 0 1 0 1 0.00 S•ace 22 23 Space 0.00 0 1 0 1 0.00 Space 24 Rev: Revised B15027 File: Ckts Marked * Existing Ckts Marked # J : \B15D27 \design \sched \Panel A Musco PH A PH 6 PH C • * Circuit Breaker Code G = GFCI H = HID Rated S = Shunt Trip C = HACR Rated D = Switching Duty # = See Note A =AFCI Connected KVA 1.20 1.50 1.00 PNL Notes: Load T •e Conn KVA NEC Demand Factor Dem. KVA Dem. Ames NEC Feed % NEC Feed Ames 1 Equip 0.50 x 100% 0.50 1 x 100% Recept 3.20 10 KVA © 100 %, rest 0 50% 3.20 9 x 100% 9 3.70 10 Amps 3.70 10 10 PANEL SCHEDULES 92.0 SCALE: NONE RECEIVED SEP S 02008 PERMIT CENTER U z Omaimmoi Mnisammol intammi C z F- M 0 J 0 J LU 0 Ct LLB (/) 0 0 0 Q) J Q 0 li F- D w LU SHEET: E2.0