Permit EL08-0130 - WESTFIELD SOUTHCENTER MALL - STARBUCKS
STARBUCKS COFFEE CO 1047 SC MALL 07-10-08 ELO8-130 City ''f Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1047 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -130 Issue Date: 05/14/2008 Permit Expires On: 11/10/2008 Tenant: Name: STARBUCKS COFFEE COMPANY Address: 1047 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: VALERIE BARTHOLME - OLYMPIC ASSOCIATES Phone: 206 - 674 -6107 Address: 701 DEXTER AVE N #301 , SEATTLE WA Contractor: Name: SOUTHGATE ELECTRIC INC Phone: Address: 23444 30 AV S STE 101 , KENT WA Contractor License No: SOUTHEI366P 1 Expiration Date: 08/30/2009 DESCRIPTION OF WORK: ELECTRICAL SYSTEM FOR RESTAURANT TENANT IMPROVEMENT Value of Electrical: $20,000.00 Fees Collected: $512.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: WIL Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to giv uthority to violate or cancel the provisions of any other state or local laws regulating construction or the performer work. I orized to sign and obtain this electrical permit. Signature: Print Name: Date: -57-/Y-- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -130 Printed: 05 -14 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 1047 SOUTHCENTER MALL TUKW STARBUCKS COFFEE COMPANY Permit Number: Status: Applied Date: Issue Date: EL08 -130 ISSUED 02/08/2008 05/14/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance o ork. Signature: Print Name: � 2 , s Date: doc: Cond -Elec EL08 -130 Printed: 05 -14 -2008 CITY OF TUKWIL Community Development Depailment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hifp 17www. ci. tukwila. wa. us • Electrical Permit No. EL-09— 1 t Project No. ?0•6'00' (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted' for plan review. Applications will not be accepted "through the mail or by fax, * *Please Print ** SITE LOCATION _ King Co Assessor` "s Tax No.: �c�367 ;? (t!) Site Address: (�`T� % P u` /l� _ Suite Number: - _ Floor: Tenant Name: S -Pti 1-z--,0ci-S cY,i — er.ANA PA-t.11-r- New Tenant: Yes ❑ ..No Property Owners Na me: W t ST't t. j�c---l` d - – - Mailing Address: (93_ - cam ✓ C2, l OA_. LLb- � �� —1 14 cl P) Zip City Stale CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: VA —( 1E- _S 22t1 --V - Mailing Address: E -Mail Address:Vbdt vh e ajc.,1 cn!t nth Js c-, tcL Day Telephone :_, 0.6 674 . b 1 U City state Zip Fax Number: c ?6, .s_, — 3 '7/ ELECTRICAL CONTRACTOR INFORMATION Company Name: l .il• E' (' V1' ✓1 E Mailing Address: stale Contact Person: E -Mail Address, Contractor Registration Number: - City Day'Teiephone: Fax Number: Expiration Date: - ;zip Valuation of Project (contractor's bid prieee) Scope of Work (please provide detailed information): .s♦ e a e S e -e:i Will service be altered? ❑ yes ❑ No Type of Use: _ Type of work: New ❑ Addition ❑ - Service Change ❑ Lbw Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Adding more than 50 amps? Ye's ❑ No ❑ Remodel Tenant Improvement Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light Ii4W( mliei- ions Torms'Applicetionsih .LmeW -2007 = F= lectrical Permit App iatioaAnc hh Pagel & 3 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings - - - - - -- - - '$140'00 VS .0-6 $55.00 ea (including an attached garage) El Garages, pools, 'spas and'outbuilditigs ❑ Low voltage systems (alarm; furnace thermostat),- RESIDENTIAL REMODEL.AND- SERVICE CHANGES. El Service change of alteration - -- —$75 00 (no added/altered circuits) ❑ Service change with addedaltered circuits - -- - $75.00 number of added circuits— '$10:00'ea ❑ Circuits added/altered without service change $5000 (up to 5 circuits) ❑ Circuits added/altered without service change - $50:00 (6 o more "circuits) $7:00 ea 111 Meter /mast repair t63:66 ❑ Low voltage systems —$55:00 (alarm; furnace thermostat) MULTI - FAMILY AND'COMMERCiAL Fees aree based on illoValuation of the elec'trical'contraci- MISCELLANEOUS _FEES ✓ Temporary Service (residential) — $58.00 ❑ Temporary "service '(generator,) — -- $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) �❑ 'Carnivals $75.00 Number ofteridessions— $10:00 ea PERMIT APPLICATION NOTES - Value of Construction = In all "cases, a value of construction amount should be entered by the applicant This figure will be reviewed and is "subject to possible 'revision by` the Permit "Center to comply with current fee schedules: Expiration of Plan Review — .Applications Mr which no permit is issued within 180 days following the' dateOf'aPplie2tion "shali expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension'shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND 1 -AM AUTHORIZED TO APPLY FOR THIS, PERMIT. BUILDING OWNER -OR ELECTRiCALCONTRACTOR: Signature: Print Name: Mailing Address: Date: _ C Telephone: _ 4774 -•6/6? Date Application Accepted: Date Application Expires: g I Stafflnitials: H:WpplicazIonsWomu= Applications pn Linc4-2007 = Ekcmcal Pemmii Application doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -130 Address: 1047 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/08/2008 Applicant: STARBUCKS COFFEE COMPANY Issue Date: Receipt No.: R08 -01621 Payment Amount: $410.00 Initials: WER Payment Date: 05/14/2008 11:15 AM User ID: 1655 Balance: $0.00 Payee: SOUTHGATE ELECTRICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 60733 410.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 410.00 Total: $410.00 2404 05/14 9710 TOTAL 410.00 doc: Receiot -06 Printed: 05 -14 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -130 Address: 1047 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/08/2008 Applicant: STARBUCKS COFFEE COMPANY Issue Date: Receipt No.: R08 -00368 Payment Amount: $102.50 Initials: WER Payment Date: 02/08/2008 02:51 PM User ID: 1655 Balance: $410.00 Payee: OLYMPIC ASSOCIATES CO TRANSACTION LIST: Type Method Description Amount Payment Check 25452 102.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 102.50 Total: $102.50 8401 02/11 9710 TOTAL 1054.50 50P doc: Receiot -06 Printed: 02 -08 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Cog- X30 Project: 46 Type of Inspection: ^/0(3 Address: i ©Lnv " Date Called: �+ Special Instructions: 1 Date Wanted: /'i 0 (a.nL, m. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. OMMENTS: D 7rii\iAt, Inspector:dill Date: 0716/>, ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 60V -13c7 Project: 6V64I5 Type of Inspection: �od3 Address: /041 l t p Date Called: Special Instructions: Date Wanted: 7/67 (J a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: D 66(un Cep a.K. kokAil (Inspector: JA7 EicifA/et rome 01P5 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit tL4 f3o PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 6 0� J f lam- Type of Inspection: 7001 ' Address: q / Date Called: Special Instructions: Date Wanted: 7/0/ Sn. Requester: Phone No: Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: D7 /0l ick El $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .1,4644... - . -- ' ` '• • •rant 1.46~. • W.1.r,.r►•S��. yr.w.. fi+�. �•ery..n' aaF .mss_..._. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ttoQ -1; 0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 Project: S :61/6.- , ` �r j 016 ct! I v Et Eivt fOfZ Type of Inspection: -BUG Z ,, E-4L9A)4 Txhidigmfiig ,Vrif 77 - Ad�d/reess: 17 66, %� / Date Called: special Instructions: Date Wanted: 7/3 a.m m. Requester: Phone No: ElApproved per applicable codes. fErrections required prior to approval. COMMENTS: , ` �r j 016 ct! I v Et Eivt fOfZ NT//?( 1,4.4i6 71 ,, E-4L9A)4 Txhidigmfiig ,Vrif 77 - 111- Giles TO �� £4 A , 2I? s. c� ,6G/GT / S -- 6E c_, , 1 G bV G-i 7( InspectX7 /4 4T6'4I/' Date: 741/4? ? $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY • F TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 a -iJ0 Project: $'8iiw e I5 Type of Inspection: 703 Address: / �Y V �� - °T4 Date Called: Special Instruction's: Date Wanted: i/ atni:. Requester: Phone No: ElApproved per applicable codes. Il Corrections required prior to approval. COMMENTS: ?4 - amu, co,,f9urry ate- F Inspector: (Date: 0 I f 103 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: L • Lr 3 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit iW 0 , /�vl PERMIT NO. 1'- (206)431 -3670 Project: s fiRcgSc� s Type of Inspection: / 7074 Address: .../ /01/ 7 v cztiJY,,ef4il., Called: Special Instructions: Date Wanted: z 9 Requester: Phone No: roved per applicable codes. ❑ Corrections required prior to approval. OM M ENTS: U K- /1-hl0 L_ .6.5 ffi73 Inspector! / / /'C ;WaVIVC Date: 6/94F J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit - ?- IS 0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: / h'q Type of Inspection: / 061 7 Address : M J 0 / ,k77/6.1-417744 r %G Date Called: Special Instructions: Date Wanted: a.m m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. OMMENTS: ,(2-W 6// /A) US Inspector; Date ❑ $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 51-27/2/1217( C Type of Inspection: 7101 Address: /U47,r- 4t. Date Called: Special Instructions: Date Wanted: s // !/ a�.mm. Requester: Phone No: proved per applicable codes. p Corrections required prior to approval. COMMENTS: /3,4 O — /AWSt,12 64 J -o�lil/ AF- ail /.s /rdtc GvfILL I ns p,�f>:b/ z. ( Date: r- $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: Structural Calculations Starbucks Southcenter 11 1047 Southcenter Mall Tukwila, Washington 98188 REVIEWED CODE COMPLIANCE NFPA 70 - NEC MAR 2 7 mg Prepared for Starbucks Coffee Company March 03, 2008 Project Number 2007228 INCOMPLETE LTR #�� j 43f43f Tukwila B ILDIN _ D I FILE COPY £LO& 130 '°.CElVED MAR 0 4 2008 PEHMII CENTER Project Information Starbucks Southcenter 11; Tukwila WA March; 2008 Project Starbucks Southcenter 11 Address '1047,Southdenter Mall Tukwila; WA '98188 Job' No 2007228 Designer Justin J Franklin Date 03/03/08 Scope: ,Analysis of 'transformer support. Referenced Building Code and Specifications; Product Guides and Manuals Design Code: 2006 International Building Code With Washington State Amendments Design Specifications' 2002 AISI Cold Foimed Steel Design Manual Project Notes: Table of Contents: Miscellaneous Framing Elements Seal Justin J Franklin 'EXPIRES 12/14/ Oe _ 1 OLYMPIC CONSULTING SERVICES, LLC Client Project Subject Date Project No. Page -- 61 E.& ?vD F- 1/4-3 •k t.*L -L F0F7 t) 45- Nspo� r es 72 !I 1-4t, saL4 E 1,t)m oV N1-h'# MFG— 72- !�9 _ •t-i A Wholly Owned Subsidiary of Olympic Associates Company 701 Dexter AvenJe North #301, Seattle, WA 98109 -4342 t: 206.285.4300 f: 206.285.4371 OLYMPIC CONSULTING SERVICES, LLC a 1 Client Date Project Project No. Subject Page 4,1 / sct s I hl /d 4vtic Fero- c t M €Ni = 1570 .V IS-7o �5 3. o 1::)//or 96 ?idol- Lj / /45 � 7727 )1 rvb Sr l 4 K gP )'-- Mir , /3oC' M i¢lLV� SrZ0o ig��z 11,-1r � f _. o� 1,p A Wholly Owned Subsidiary of Olympic Associates Company 701 Dexter Avenue North #301, Seattle, WA 98109 -4342 t: 206.285.4300 f: 206.285.4371 IV -10 Connecti0n5 for -Lite with the 2001 `North American COId- Formed Steel Specification Tattle IV =Se Screws .Shear' Of Sheet- Fu = 45 kst li -3:0 Ili ='Od5 Nominal Shear Strength, Phi, kips Screw Designation Diameter in. Thickness of member in contact with Thickness of member not in contact With thescrew head, in. 1 screw head; in. 0.036 6.048 '0:060 0:075 0:090 0.105 0.135 0.036 0.480 0.604 11604 0.604 0.604 0.604 0.604 0:648 '0:486 0.738 0.805 '0:805 6805 '0:805 0:805 #6 0.138 0.060 11480 0.738 1.01 1.01 I 1.01 1.01 1.01 0.075 0.480 0.738 1:01 1.26 1.26 1.26 1.26 0.090 6480 0.738 1 :01 1226 151 1.51 1:51 0.105 (1480 0:738 . 1.01 1.26 1.51 1.76 1.-76 0.135 0.480 0.738 1.01 1.26 1:51 1:76 2,26 0.036 0 :523 0.717 0.717 0.717 0.717 0.,717 0:717 (1048 0 :523 0.805 0.956 0:956 0:956 0:956 0 :956 #8 0.164 '0.066 11523 ' 0.805 142 1.20 1.20 1:20 '1:20 1. (6:075 '0:523 0:805 1.12 1 :49 1_:49 1 1:49 1:49 1 0.090 '0:523 ' 0.805 1.12 1.49 ) 1.79 1.79 179 0.105 0:523 0.805 1.12 `1.49 1 :79 2.09 2:09 0.135 0.523 '0 :805 1:12 . 1.49 1.79 1 2.09 `2.69 0.036 '0.563 0 :831 0.831 , 0:831 0.831 0.831 0.831 0.048 0.563 0.866 1:11 1.11 1.11 1.11 1.11 #10 '0.190 '6066 0.563 0.866 121 1.39 1:39 '1'39 139 '0.075 0.563 0.866 1.21 1.69 1.73_ L73 0.090 0.563 0.866 1.21 1.69 " 2.08) 2.08 2:08 0.105 0.563 0.866 1.21 1.69 • 2.08 142 2:42 0.135 '0:563_ 0.866 1.21 1.69 I 2.08 '2.42 _ 3:12_ 0.036 0.600 0 :928 0.945 0.945 ■ 0.945 0 :945 0.945 0.048 0.600 0.924 . 1.26 1:26 11.26 126 1.26 #12 0.216 0.060 0.600 0 :924 1.29 1:57 1.57 1.57 ,1.57 0.075 0.600 0.924 1.29 1.80 1.97 1.97 ! 1.97 0.090 0 :600 '0.924 � `1.29 1.80 236 2:36 'i 236 0.105 0.600 0.924 1.29 1.80 `:'-236 2.76 2.-76 10.135 0.600 '0:924 1.29 1:80 /- 236 2:76 3.54 0:036 0:645 ,, 1.02 1:09 1 -09 1109 1.09 1. 1.09 0.048 '6645 . 0.494 1.40 1.46 1.46 1.46 146 1%4 in 0.250 0.060 (1645 11 i 0.994 1.39 1.82 1.82 1:82 ' 182 , 0.075 0:645 0.994 `1.39 1.94 2:28 2:28 ii 2.28 .0:090 0,645 0:994 1:39 1:94 2:55 2:73 ,! 2.73 '0.105 0.645 0.994 1.39 1.94 2.55 3.19 1! 3.19 '0.135 0:645 0.994 1.39 1.94 2.55 _ 3 :19 li 4 :10 Note: Deslgn Strengths are: ASD: P,s / 52 LRFD: 4P IV -12 Connections for use with the 2001 North American Cold= Formed Steel Specification Tattle IV - 9a Screws Q_ 3.0 'Pull -Out - Fu = 45 kill = 0:5 Nominal Pullout Strength, Pao, kips Screw Designation I, Diameter 11 in. Thickness of 'member not in contact with the screw head, in. 0.036 I 0.048 0.060 0.075 '0.090 '0.105 '0135 #6 0.138 0.190 0.253 0.317 0.396 0:475 0:554 0.713 #8 0.164 0.226 0.301 0.376 0.470 0.565 0.659 0.847 #10 0.190 0.262 0:349 '0.436' 0.545 0:620 0.654 '0:763 0:981 #12 __ 1%4 in. _ 0:216 0.297 '0:397 0:496 L 0:574 _'107717 0:744 0.861 0:868 1 -00 1.12 0..250 0.344 '0.459 1.29 Tame IV - 9b 52= 3.0 Screws • = 0.5 Pull -Out - F„ = 65 ksl Nominal Pullout Strength, Pnot, kips Screw Designation Diameter in. Thickness of member not in contact with the screw head, in. 0.036 0.048 0.060 0.075 0.090 0.105 0.135 #6 0.138 0.274 0.366 0.457 0.572 0.686 0.801 103 es 0.164 0.326 0.435 0.544 0.680 0.815 0.951 122 #10 0.190 0.378 0.504 0.630 0.787 0.945 110 1.42 #12 0.216 0.430 0.573 0.716 0.895 1.07 1.25 161 1/4 in. 0.250 0.497 0.663 0.829 1.04 1.24 1.45 1.86 `Noes Design Strengths are: ASD: !Ph-fit- / 52 LRFD: Beam Design for use with the 2001 North American Cold- Formed Steel Specification Table 1I - 2 (continued) Beam Properties SSMA Studs C- Sections With Lips Section Vn kips Fy = 33 ksi, F, = 45 ksi Fya 3 ksi. Mnxo 1 kip-in. Se in.3 800S137 -97 7.72 41.25 88.7 2.15 8.60 8005137 -68 5.39 50.9 1.54 6.30 8005137 -54 3.35 38.9 1.18 5.08 800S137 -43 1.68 29.6 0.896 4.00 8005137 -33* 0.758 20.5 0.622 3.00 600S250 -97 11.1 37.72 81.5 2.16 6.50 600S250 -68 6.96 36.36 54.8 1.51 4.73 600S250 -54 4.38 38.2 1.16 3.82 600S250 -43 2.27 30.3 0.918 3.08 600S200 -97 11.1 38.83 72.6 1.87 5.61 6005200 -68 6.96 37.16 50.8 1.37 4.10 600S200 -54 4.38 36.34 40.2 1.11 3.32 600S200 -43 2.27 28.8 0.873 2.68 600S200 -33 1.02 20.4 0.618 2.06 600S162 -97 4.02 40.08 64.1 1.60 4.80 600S162 -68 3.74 38.07 44.7 1.17 3.52 6005162 -54 3.02 37.07 35.3 0.954 2.86 600S162 -43 1.98 36.30 27.9 0.767 2.32 6005162 -33 1.02 19.1 0.577 1.79 600S137 -97 4.02 41.25 57.6 1.40 4.19 6005137.68 3.74 38.94 40.2 1.03 3.09 600S137 -54 3.02 27.5 0.832 2.52 600S137 -43 1.98 21.3 0.645 2.04 6005137 -33 1.02 15.0 0.455 1.55 550S162 -68 3.29 38.07 39.6 1.04 2.86 5505162 -54 2.67 37.07 31.3 0.845 2.32 5505162 -43 1.92 36.30 24.7 0.681 1.88 550S162 -33 1.12 16.9 0.512 1.46 4005200-68 5.14 37.16 29.5 0.795 1.59 4005200 -54 4.17 36.34 23.5 0.646 1.29 400520043 2.78 16.8 0.509 1.05 400S200 -33 1.56 - 12.0 0.363 0.805 400S162 -68 1.43 - 21.7 0.658 1.33 4005162-54 1.51 17.3 0.526 1.08 400S 162.43 1.30 13.7 0.417 0.870 4005162 -33 0.952 9.86 0.299 0.669 Fy = 50 ksi. F„ = 65 ksi Fya 3 1 Mnxo 1 Se ksi kip-in. in.3 9.50 107 2.15 5.39 1 73.4 1.47 3.35 54.2 1.08 16.8 8.56 4.52 56.17 116 69.3 53.4 16.8 57.61 8.56 i 55.44 4.52 6.09 4.61 3.12 59.24 56.63 55.32 6.09 4.61 3.12 60.78 108 73.0 50.8 94.7 65.9 50.6 2.06 1.39 1.07 Maximum Effective Moment 2 ie Mweb Mflange Mlip in.4 ; kip -in. kip-in. kip -in. 8.60 123 6.29 41.6 4.97 20.7 10.4 4.72 6.50 354 4.72 126 3.77 67.9 1.87 5.61 1.32 4.10 1.02 3.32 1.60 , 4.80 1.16 3.53 0.916 2.86 84.9 ' 1.40 51.5 ' 1.03 38.9 0.777 4.19 3.09 2.52 38.9 330 127 69.7 39.2 20.6 373 132 71.0 41.1 19.8 384 131 67.4 36:7 19.5 132 56.3 32.7 19.0 187 77.5 44.6 24.5 11.1 213 82:7 48.6 30.1 17.6 80.9 41.3 28.0 19.5 125 60.9 40.5 27.6 16:1 228 91.7 51.9 30.1 15.2 143 63.7 40.6 27.1 17.2 150 50.8 25.0 12.6 5.70 4.05 55.63 58.4 1.03 2.86 129 3.01 55.32 44.9 0.811 2.32 66.5 - I - I - 7.79 1 55.44 T 42.4 0.766 _ 1.59 5.39 29.4 0.589 1.29 4- 2.17 - 32.4 0.648 1.96 - 24.9 0.498 • 36.5 19.4 125 65.5 37.0 - ' 19.1 1.32 0.00 1.07 0.00 0.00 0.00 234 91.5 50.5 28.5 15.0 148 58.3 34.6 21.6 12.8 81.2 45:9 26.7 13.5 56.4 36.0 24.1 15.2 45.1 26.1 14.3 6.49 48.7 27:5 16.0 8.12 35.4 23.6 16.1 9:50 35.0 22.1 14.6 9.03 0 I (E) METAL DECK AND CONCRETE FLOOR NEW 600S125 -33 TRACK FASTENED TO CONC. DECK w/ HILTI X -EDNI 16 P8 FASTENERS @ 12" o/c (E) DIMISING WALL NEW 6" STEEL STUD FURRING WALL 600S162 -54 STEEL STUDS AT BRACKET ATTACHMENT LOCATIONS WALL MOUNTING BRACKETS BY TRANSFORMER MFR. ANCHOR BRACKETS TO STEEL STUDS WITH (2) #12 SCREWS EACH BRACKET TO BE MOUNTED BELOW THE PLENUM NEW 600S125 -33 TRACK FASTENED TO CONC. FLOOR w/ HILTI X -EDNI 16 P8 FASTENERS @ 12" o/c (E) CONCRETE FLOOR DATE DRANK CHECK JOB 2007228 02/28/08 JR JF STARBUCKS SOUTHCENTER 11 TRANSFORMER BRACKET ATTACHMENT SCALE 314° =1' -0' cOPFRnRO WM 012 PC ASSOCIATES COMPANY 'MESE DOCUMENT. TIE OEM AND DERMAS PSOPOPATED SIMMS AS AM V181ROTENT OF SERVICE ARE TIR PROPERTY . OLYMPIC A®OCIAT® CO ART AM ME NOT TO SE USED M MOLE OR M PART xCNOUTWRRTEN AUOCROATn1 OF OLMIC ASSEMATES COVART • 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2008 Washington State Nonresidendal Energy Code Compliance Fans Redeed July 2007 Project Info Project Address st risucks (SOOTIMENTER 7=) Date 1/25/2008 eo6 Southaenter Blvd, #1310 For B(Ing . .< 1 :-_ • .,''':'l ED CODE COMPLI NFPA 70 - f MAR 201 Tukwila, Washington 98188 Applicant Name: AEE mss, 121C. Applicant Address: 11153 120th Ave NE, Eiskland, 901 98033 Apph Phone: 425- 739 -6051 Project Description BAR AREA =NWT POE FOOD PASPABATIO®1 0 flans ..:: / • New Building • Addfan o Alteration Refer to WSEC Section 1513 for controls and commissioning requi : ts.C� Of Tukv 1' > >y . Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 System (See Oualificalion Cheer (o. Irk Prescriptive & LPA spaces cle1y on !!L1 -, �1:llil`1�1 �' -. plans.) Alteration Exceptions (check appropriate box - sec- 1132-3) 977. 6 10 • No changes are being made to the lighting & space use not changed. • Less than 60% of the Mures new, installed wattage not Increased, Maximum Allowed Lighting Wattage Location (floor/room no.) Occupancy Description Allowed Watts per ft? " - - - Area in 1t2 Allowed x Area TENANT SPACE FAST roan 1:30 752:0 9776 TYPE L563 BAR AREA =NWT POE FOOD PASPABATIO®1 3 294.0 288.0 TYPE 7500 Recessed Compact fluor. (1 -18r TTY lamp) 1 20.0 -- " From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 977. 6 Proposed Lighting Wattage lys OR ANCE fEC 8 ila Location (floor/room no.) Fod re Description Number of Foctures Watts/ F'odcre Watts Proposed TYPE 1.145 Baakhar track lighting (Exempt in food prep area) (in 1.r) 11 TYPE L563 2x4 Fluor. Troffers (3-Te lamps) 3 96.0 288.0 TYPE 7500 Recessed Compact fluor. (1 -18r TTY lamp) 1 20.0 20.0 TYPE L500 Recessed Compact fluor. (Exempt in food prep area) 10 TYPE L530 Pendant 'It'd Inc. (Enept in food prep area) 1 TYPE L037 floor. Pendant (1 -18w TTT Lamp) 4 20.0 80.0 TYPE 3nL5 1x4 Fluor. Strips (2-TO lamps) 3 64.0 192.0 Total Proposed Watts may not exceed Total Allowed Watts for Irderior Total Proposed Watts 580.0 Notes: 1. For proposed Fixture Description, indcate fbdure type, lamp type (e.g. T -8), number of tamps in the fixture, and bast type (if included). For track lid, list the length of the track (in feet) in addition to the fodure, lamp, and ballast Information. 2. For proposed Watts/Fature, use manufacturer's meted ma dint n input wattage of the fochae (not simply the lamp wattage) and ether criteria as specified in Section 1530. For hard -wired ballasts only, the defauft table in the NREC Technical Reference Manual may also be used. For tract lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current Fowling devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fbdure blank. p 1-7cr r0 ELO8 - (30 FILE COPY FEB 08 NO3 Pti1M1T GLn1 ER I 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code CompFianoe Fortes Revised Juty 2007 Project Address Stasbooks (socr II) rate 1/25/2008 The following information is necessary to check a perm appfication for compliance wfih the ligMing, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. (yes, n.a.) I Section (C 'Information Required Location on Plans &Alm Department Notes LIGHTING CONTROLS (Section 1513) Yes 1513.1 Local control/access Schedule will type, indicate locations - - s3 . o yes 15132 Area controls Maximum limit per switch 83.0 yes 1513.3 Daylight zone control Schedule with type and features, indicate locations 13.0 yea vertical glazing Indicate vertical glazing on plans 83.0 n. a. overhead glazing Indicate overhead glazing on plans - - — - Yes 1513.4 Display/exdnih/speclal Indicate separate controls g3.0 1513.5 Exterior shut -off Schedule with type and features, indicate location Yes (a) timer rsdbacnrp Indicate location - - 13.0 fl. a . (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indite location fl. a . 1513.6.1 (a) occup. sensors Schedule with type and locations fl. a . 1513.6.2 (b) auto. swims Schedule with type and features (back-up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning trhdicate requirements for lighting cords commissioning 13.0 EXIT SIGNS (Section 1514) -- yes I 1514 'Max. watts 'Indicate watts for each ez t sign 1E3.0 I LIGHTING POWER ALLOWANCE (Section 1530- 1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fodure attache yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per future ,, "�`�` MOTORS Section 1511) no 1511 IEtec motor efficiency IMECH -MOT Or Equipment Schedule wtrh hp, rpm, efficiency 1 I TRANSFORMERS (Section 1540) n - a - [ 1540 1Transfonners !Indicate size and efficiency I- I- If "no" is circled for any question, provide explanation: sus RTC F!.../(Tr) CIiy is r i . ''LA FEB 0 8 2008 PthiVII T CENTER February 15, 2008 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Valerie Bartholme 701 Dexter Avenue N, #301 Seattle, WA 98109 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -130 Starbucks Coffee Company — 1047 Southcenter Mall Dear Ms. Bartholme, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on February 8, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4758, if you have any questions concerning the following comments. 1. Provide structural and seismic engineering and detail for transformer above the ceiling grid. 2. Provide an average 1 foot candle illumination at floor along egress pathway and exit discharge. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. 1 have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, 4104411L- Brenda Holt Permit Coordinator Enclosures File: E1.08 -130 P:\Permit Center\Incomplete Letters \2008\EL08 -130 incomplete Ltr # 1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -130 DATE: 03 -04 -08 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 1047 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTM NTS: PA Jg Ivision Public Works Fire Prevention Structural n Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 03-06 -08 Complete Comments: Incomplete Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 111 Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-03-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 4111ERMBT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -130 DATE: 02 -08 -08 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 1047 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: 2 .08 Building Piv s�iorl !.1 Public Works n Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 02 -14 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: 2 'Kirk LETTER OF COMPLETENESS M ED: Departments determined incomplete: Bldg u Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03 -13 -08 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 1 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.citukwila.wa.us 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: ((1 s (I 3 �C c)S Plan Check/Permit Number: EL00 -130 ® Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: STARBUCKS COFFEE COMPANY Project Address: 1047 Southcenter Mall Contact Person: Valerie Bartholme Summary of Revision: tDtr Phone Number: U" O 3 . ���' _ (?�vist�� -- l L.2.0 P3Ul , `Ul Z.! g.22 rn . v E./. 1 . c f a- 4- �1'fv OF TIIKWILA Sheet Number(s): MAR OA infB "Cloud" or highlight all areas of revision including date of revision c---7) Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 3- 21-001 \applications \forms - applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SOUTHEI366P1 Licensee Name SOUTHGATE ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 578089488 Ind. Ins. Account Id Business Type CORPORATION Address 1 23444 30TH AVE S STE 101 Address 2 City KENT County KING State WA Zip 98032 Phone 2068782866 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/21/1964 Expiration Date 8/30/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License BRENNPJ066RC Electrical Administrator Information License BRENNPJ066RC Name BRENNAN, PATRICK JOSEPH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date STEIGERS, HERBERT C 01/01/1980 PASCHOS, CHRIS 01/01/1980 PSACHOS, CHRIS AGENT 01 /01/1980 PSACHOS, BARBARA SECRETARY 01/01/1980 08/03/2001 • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer. aspx ?License= SOUTHEI366P 1 05/14/2008 ALL CONNECTIONS TO METAL DECK SLABS FOR STRUCTURAL LOADS SHALL BE EITHER PRESET OR DRILLED IN ANCHORS WALL BLOCKING KEY: WALL TYPE LEGEND: SYMBOL ITEM WEIGHT HEIGHT AFF "I SHELVES ABOVE 3 -COMP SINK SHELVES AND DATA RACK AT MANAGER'S DESK 200 LBS 300 LBS 5'--8" TO 6'--0" Y2" ACX PLYWOOD UPPER STORAGE (CUBBY) CABINETS AT BACKBAR E•ft-I -'r"S :ISIONS No changes :;'-,.;ill be rn-a-rile, to thie of of work °MMithout prior approval Tukwila Building Division NOTE: Revisions will require a new nln submitfnl n, -- i and may include additional plan review fees o 8 o No 1 % BACKBAR 04 lik... 0 r////////////////////////////Ae/ // / / / / / //I/ Ill//////////%////////////// ✓ / / / / / / / / / /'// / / %eF2Ui %� / / / //// CONSTRUCTION PLAN �fz APPROVED P! qtr.' n?rrl 7;nrr:7IOATir. 1`7 Clt -A1 i^ " rrn1- r2T !P NGED. MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BOWING 07IC!Al , ALl WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND is 'i: :T TO F► ~'.0 INSPEOTIOf lC V.I.F. STARBUCKS LEASE LINE APPROX. WIDTH 8' -0" CENTERED ABOVE 3 -COMP SINK WALL TYPE 7' -0" CENTERED ABOVE MANAGER'S DESK AND DATA RACK BLOCKING SPECIFICATION FOR FRENCH CLEAT MOUNTING SYSTEM TO BE DETERMINED BY ARCHITECT OF RECORD BASED ON INFORMATION PROVIDED ON STARBUCKS' AEC WEBSITE. FILE COPY Permit No. EXISTING WALL NEW PARTI71ON WALL TO 6" ABOVE CEILING 20 GA 35/8" MTL STUDS 16" O.C. WITH 5/8" TYPE "X" GWB ON ONE OR BOTH SIDES TO MIN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS @ 12" 0.C.. 45 DEGREE MTL STUD REINFORCEMENT @ 48" 0.C. ABOVE CEILING LINE TO STRUCTURE ABOVE. CONSTRUCTION /DETAIL LOCATION SEE DETAIL 1/A2.1 NEW 1 HOUR PARTITION WALL AT FNISHED COR SEE DETAIL 4/A2.1 Plar review approval is subject to errors and omissions. Approval of construction document does not authorize the violation of any adopted * • or ordinance. Receipt of approved Field I • is wed: By Date:..,. - l City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: at Mechanical ❑ Electrical I Plumbing or Piping City of Tukwila BUILDING DIVISION 1 (E) META DECK AND CONCRETE FLOOR NEW 600S125-33 TRACK FASTENED TO CONC. DECK w/ HILTI X -EDNI 16 P8 FASTENERS @ 12" o/c N W FU "ED PLUMBING WALL TO 6" ABOVE CEILING W/ GREENBOARD 20 GA 6" MTL STUDS 16" 0.C. WITH 5/8" GREEN BOARD TO CEILING. SECURE THE GREEN BOARD TO STUDS WITH DRYWALL SCREWS AT 10" 0.C. AT PANEL EDGES AND 12" 0.0. AT INTERMIATE SUPPORTS. 45 DEGREE MIL STUD R INFORCEMENT @ 48" 0.C. ABOVE LING LINE TO STRUCTU i BOVE NEW PLUMBING WALL TO 6" ABOVE CEIL rt EXISTING WALL LOTCO 20 GA 6" MTL STUDS 16" 0.C. WITH 5 /a" TYPE "X" OWE ON ONE OR BOTH SIDES TO MIN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS @ 12" 0.C.. 45 DEGREE MTL STUD REINFORCEMENT AT 48" 0.0. ABOVE CEILING LINE TO STRUCTURE ABOVE. NEW PARTIAL- HEIGHT WALL 20 GA 35/8" MTL STUDS 16" 0.C. WITH 5/8" TYPE "X" GWB ON BOTH SIDES TO SPECIFIED HEIGHT. DRYWALL SCREWS @12" 0.C.. NEW PARTITION WALL - HEAVIER GAUGE STUD 16 GA 35/8" MTL STUDS 16" 0.C. WITH 5/8" GREENBOARD ON BOTH SIDES TO MIN OF 6" ABOVE CEILING GRID. DRYWALL SCREWS @12" 0.C.. L REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR 2 7 2008 V�Y City Of Tukwila BUILDING DIVISION (E) DIMISING WALL NEW 6" STEEL STUD FURRING WALL 6005162 -54 STEEL STUDS AT BRACKET ATTACHMENT LOCATIONS WALL MOUNTING BRACKETS BY TRANSFORMER MFR. ANCHOR BRACKETS TO STEEL STUDS WITH (2) #12 SCREWS EACH BRACKET TO BE MOUNTED BELOW THE PLENUM NEW 6005125 -33 TRACK FASTENED TO CONC. FLOOR w/ HILTI X -EDNI 16 P8 FASTENERS © 12" o/c (E) CONCRETE FLOOR ublic Works, Building Division ERMIT NUMBER 4 4 0811 Date A 74;11 ,EATT NOTES: GC TO VERIFY ALL DIMENSIONS AND NOTIFY STARBUCKS CM OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. ALL DIMENSIONS TO BE TAKEN FROM DESIGNATED DATUM POINT. PROVIDE FIRE TREATED 2X6 OR 2X8 WOOD STUD BLOCKING AS REQ'D TO SUPPORT ANY WALL ATTACHMENTS. NUMBER NOT USED NUMBER NOT USED ® NUMBER NOT USED O NUMBER NOT USED 0 1/4" GREEN BOARD ON BACKBAR WALL. ® EXISTING COLUMN, GC TO V.I.F. Q CASEWORK PANEL, SEE A7.0 FOR SCHEDULE INFORMATION 10 GWB BOARD ON ONE SIDE ONLY 11 SUPPORT COLUMN FOR MOTORIZED ROLLING GRILLE WALL TYPE KEY: TRANSFORMER BRACKET WALL ATTACHMENT NTS EXISTING WALL: NEW WALL: NEW FURRED WALL: INCOMPLETE RECEIVED MAR 04 2008 PERMIT CENTER ELO8 13a STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. ARCHITECT OF RECORD 8758 REGISTERED ARC Val Earl STATE • ASHINGTON 781 Uerrar Avenue 8013 5301 Sniffle, WA 98109 -4344 t: 306.485.4300 f: 106.185.4311 ;. www.olyopitossodotes.raro OLYMPIC ASSOCIATES COMPANY REV DATE PD DESCRIPTION STARBUCKS COFFEE `a " "' SOUTHCENTER 11 1047 SOUTHCENTER MALL T U KW I LA, WA 98188 z 0 0 0 z z O U STORE #: 14777 PROJECT #: 12197 -001 CONCEPT: SM FT PRNT PALETTE: diMODA ISSUE DATE: 02.01.08 DM: ROY HWANG PD: MICHELLE PIERRE CHECKED: SCOTT LaROSE CM: DIANE RANDECKER OAC CHECK: VALERIE BARTHOLME SHEET TITLE CONSTRUCTION PLAN SCALE: 1 / 4 " =1' -0" (DO NOT SCALE DRAWINGS) SHEET NUMBE HVAC SCHEDULE: HVAC SCHEDULE: / .RBA Y �� ���� _+ '' (CONFIRM ALL QUANTITIES WITH PLAN VIEW AND STARBUCKS) ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SHIP ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP SUPPLY AHU- -1 1 3.0 TON AIR HANDLER LENNOX CB30M --41 -1 G W /OUT ELEC. HT 460V/10 MCA�2 MOCP =15 INDIRECT 3.0 TON CAPACITY 1200CFM ®0.5 MAX ESP WEIGHT =177 LBS CD-1 CD-2 CD -3 4 SQ. 4 -WAY SUPPLY - HARD LID TITUS TDC #6 - 12X12 18X18 4 -WAY - 12IN DUCT GC 2 SQ. 4 -WAY SUPPLY - LAY -IN TITUS TDC #3 - 14X14 24X24 4 -WAY - 14IN DUCT GC 1 24" 24 SLOT DIFFUSER TITUS MP -39 3EA 1 "SLOTS 24" LENGTH 8 "0 DUCT CONN. GC STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 CU -1 1 3.0 TON A/C UNIT LENNOX TSA036 -S2N41 G 460V/30 MCA =7.6 MOCP =15 3.0 TON COOLING CAPACITY 1 3.0 SEER W /OPTIONS AS NEEDED WEIGHT= 1 50LBS RETURN RG -1 RG-2 2 SQ. RETURN - HARD LID TITUS 350RL - 22X22 24 X 24 FACE HARD LID VAV --1 1 SERIES POWERED VAV FAN TERMINAL BOX ENVIROTEC 12 CFR -1221 W /ECM MOTOR& 6.0 KW ELEC HT MOTOR: 277V/10 HEATER' 480V/1 MOTOR: FLA =5.5 HEATER: FLA =21.7 1 CFM FAN ® 0.9" MAX ESP 1600CFM MAX /300CFM MIN PRIME AIR 3 /4HP ECM MOTOR W /OPTIDNS A5 NEEDED H254 2 SQ. RETURN -- LAY-IN TITUS 350RL #3 22X22 24X24 - 22" DUCT GC STARBUCKS' NAME AND CLOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. MI SC H501 1 THERMOSTAT WITH SENSOR HONEYWELL T7351 F W/ T7770 REMOTE SENSOR GC CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. (425) 739 -6051 SUITE 200 (425) 739 -7362 KIRKLAND, WA 98033 AER123 @AOL.COM HVAC ROOF PLAN 0 O HVAC PLAN KEY NOTES - - 28 2 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL MECHANICAL EQUIPMENT. ® F &I SAMPLING TUBE AND DUCT SMOKE DETECTOR IN AIR PLENUM. INTERLOCK DETECTOR WITH RESPECTIVE HVAC UNIT TO SHUT DOWN UNIT UPON DETECTION OF SMOKE, COORD. W /ELECTRICAL AND SEE POWER SHEETS FOR FURTHER REQUIREMENTS AND REMOTE ANNUCIATOR. INTERCONNECT WITH CENTRAL SYSTEM IF APPLICABLE. 0 NUMBER NOT USED. Q WALL MOUNTED THERMOSTAT FOR ROOFTOP A/C UNIT AT 60" AFF. THERMOSTAT SHALL BE 7 -DAY PROGRAMMABLE WITH NIGHT SETBACK AND A MINIMUM 5 DEGREE DEADBAND. CONFIRM HEIGHT COMPLIES WITH BARRIER FREE, AND ALL OTHER LOCAL REQUIREMENTS. 0 REMOTE TEMPERATURE SENSOR AT 60" AFF ON WALL 0 MANUAL BALANCE DAMPER (TYPICAL). 0 NUMBER NOT USED. 0 SUSPEND VAV1 & AHU1 ABOVE CEILING W /VIBRATION ISOLATORS & FLEXIBLE DUCT CONNECTIONS. MAINTAIN ACCESS TO UNITS PER CODE & MANUF. REQUIREMENTS. 9 1" DUCT LINER IN DUCTS AS SHOWN. INCREASE DIMENSIONS OF DUCT SIZE INDICATED TO ALLOW FOR LINER. 10 MOUNT CONDENSER ON ROOF PER LANDLORD REQUIREMENTS. (CONFIRM) 22X'2 H254 REV DATE JC DESCRIPTION / ' \ 02 -26 -08 LL /CITY COMMENTS RG-2� ' ©03- -03 -08 LANDLORD REVISIONS 22X22 12X12 12X12 PRIM RY RG--1 -- CD -1 50 CD--1 500 CONNECT TO EXIST "0(EX) AIR DUCT (CONFIRM) wri 16 POWER L DISCONNECT SWITCH I��. 1 1 • ' ■ lilliallilli lib,. O O O O RECESSED ELECTRICAL PANELS II Ip� 4.: �I� re (-1) G �� 1 1 I B A C K B A R ' 1 I » 12 Ill 14X14 ENSURE UNIT IS MOUNTED A MIN. OF 6" OFF THE ROOF SLAB. 11 MULTIPLE THERMOSTATS SHALL BE STACKED IN A VERTICAL ---r O� -= - _ • _ _= CD -2 600 _ _ _ _ __ 0 ONL .�.�,� RIO, , Q • CONFIGURATION WITH A MINIMUM 8" CLEARANCE BELOW EACH THERMOSTAT. (2 F &I ENVIRO -TEC ANALOG CONTROL SYSTEM THAT IS COMPATIBLE WITH `-' SERIES FAN POWERED VAV UNIT. CONTROLS SHALL INCLUDE PROGRAMMABLE THERMOSTAT (TO SUIT STARBUCKS NEEDS), REMOTE WALL MOUNTED SENSOR, AND ALL CONTROL COMPONENTS NECESSARY FORA COMPLETE & OPERATING SYSTEM. SYSTEM CONTROLS SHALL MODULATE PRIMARY AIR VALVE AS NEEDED TO MEET THERMOSTAT'S COOLING SETPOINT. THERMOSTAT SHALL HAVE AT LEAST ONE STAGE OF HEATING AND SHALL TURN OFF /ON HEATING ELEMENT AS NEEDED TO MEET THERMOSTAT'S HEATING SETPOINT. PRIMARY AIR VALVE SHALL STAY IN MIN. POSITION DURING HEATING MODE. VAV UNIT SHALL SHUT DOWN DURING UNOCCUPIED MODE & CLOSE PRIMARY AIR VALVE. - 0 0 0 "„ I- _ i ,)fr . ■ l� _I w4 NO uI O O f f 12X12 ∎ri 1rI 2i JTHCENTER BL A, WA 98188 )LINTY CD -1 300 ¢ _ tr -111 4 18X16, F 0 1 12 "o 8 "0 a� CU-1 SURFACE MOUNT REFRIG �� 4 PIPE SLEEVE THRU ROOF FOR • " ' - STUBBED I I I � 1 SLEEVE �© r p ON ROOF LINES (2EA) & POWER CONEUIT TO CONCRETE POWER AND REFRIG. LINES. SEAL ABOVE CEILING UP THRU 2ND S FLOOR, (SEE ROOF PLAN) L E S I SEATING �- 1 IF NI .0 VAV1 VI $ me L PENETRATION PER LL ROOFING CURS,. (CONFIRM) CONTRACTOR RED( UIREMENTS. J∎ 10 " 22X22 o1 12X12 1'—" VAV1 Q -- _ _ - -7- COLUMNS AT SECOND FLOOR CD -1 300 "0 RG -1 m r•" 10 , - I I - ` e 4 I I 1 -41 ma I r - �I or I ji ) !r JU "7 I �,, i u 1 �. I 1 gill �a 24 3 -SLOT +�' 4 1 (E3 " 0 --.1-.x==--- CD -3 100 I 0 RG 2 r ��`. 11�:r .�` 4" PIPE SLEEVE DOWN THRU FLOOR TO STARBUCKS SPACE. OFFSET WITH 30 DEG. MAX ELBOWS. MAINTAIN CONTINUOUS RACEWAY FOR STARBUCKS POWER AND REFRIG. LINES TO BE PULLED THRU SLEEVE. 1 - I - .. • LL \ I • �S L J MAINTAIN CLEARANCE TO ACCESSR(CONFIRM)AND o a RE i R f - _ I- Ir I I 1 1! I Q I., O '' rll�t'�e - o o II Q • R 0 0 M (1. I NOTES 12"� `, ►�� 20X14 T T _ _ W 0 R K 1. SEE ARCH. PLANS FOR DIMENSIONED DIFFUSER LOCATIONS. 2. CEILING SPACE IS BENG PLENUM. = •J / P /�1 C - _ 2 O F &I INSULATED REFRIG. ` MANUF. REQUIREMENTS. IIII!1P4L_ AH U1 O� LLII% PROJECT #: 12197 -001 ISSUE DATE: 01/28/08 CHECKED: JOHN BEEBE DESIGNED: CHRIS BENSON DRAWN: DAN PURAVET (-- _ O V V _ � • ,- REVIEWED FOR 14X14 © ; CODE C®MPL,P NCE CD-2 600 MFPA 70 - NEC A H r - -s MAR 2 "7 2fl38 --T-- .�r b Y,;� t: w -"---Tukwila $ f City Of . HVAC PLAN � BULL ®INGDNi ION MAR 04 2t�Ud SKYLIGHT ON ROOF SHEET TITLE HVAC PLAN & SCHEDULE SCALE. (DO NOT SCALE DRAWINGS) 0 1 2 3 4 8 12 PER�AIT CENT E L x „. _. - r. (SEEOE?rOR)) SCOP F 0- �Y �/j , / .� I di .. ,v ®.,P X90 3 , "0 N � \-SCREENED HVAC UNIT AREA ON ROOF PARKING LEVEL SHEET NUMBER M 2 . 0 - 26 EXPIRES ,['� -- ___ PLUMBING GENERAL NOTES PLUMBING SCHEDULE F &I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. a PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING EQUIPMENT. Q DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED. Q REFER TO DETAIL SHEETS FOR PLUMBING FITTINGS LOCATED IN CASEWORK. FO COLD WATER SUPPLY LINES INSIDE CASEWORK & BAR AREA TO BE COVERED WITH 1/2" THICK SELF SEALING, SECTIONAL CLOSED -CELL FOAM INSULATION. REFER TO SPECIFICATIONS FOR HOT WATER SUPPLY LINE INSULATION REQUIREMENTS. aG CONTRACTOR SHALL CONTACT WATER FILTER SUPPLIER 10 DAYS (MINIMUM) BEFORE THE TIME THAT THE FILTER SYSTEM IS TO BE STARTED UP. aH STOP VALVES SHALL BE F &I AT ALL PLUMBING FIXTURES EVEN IF NOT SHOWN IN PLAN. 0 RUN ALL PIPING CONCEALED. 200A 480V 30 FUSED DISCONNECT SWITCH BY LANDLORD (CONFIRM). 3/4" CWF &CW BLOW COUNTER REMOTE RE AT 60" AFF (CONFIRM) RECESSED ELECTRICAL PANELS (CONFIRM ALL QUANTITIES WITH PLAN VIEW AND STARBUCKS) ITEM# QTY DESCRIPTION MANUFACTURER MODEL # VOLTS AMPS SUPPLY WASTE REMARKS SKU # SHIP FIXTURES P012 1 ICE BIN 95LBS - STAINLESS SPOKANE STAINLESS ZURN Z7440 -WF 1/2" CW /TW 1" 1 15 "X25 "X20" 194924 VD P021 1 SINK - 5S HAND (2 WORKROOM SPOKANE STAINLESS EHS-14-W 208V/10 5KW 1/2" IPS H/C 1 1/2" D WALL MTD W /FAUCET - ADA COMPLIANT 179715 3PL P026 1 SINK - WORKROOM 3 COMPART SPOKANE STAINLESS 3C16X20 -2 -18 1/2" CW /HW 2" D 16 X 20 X 16 120019 3PL P034 3 SINK FLOOR - 12" SQ FERGUSON ENTERPRISES ZURN FD2375 -NH3 3„ D W /3" PLUMBING TAIL PIECE 180465 3PL P036 1 MOP SINK FERGUSON ENTERPRISES ZURN Z- 1995 -24 1/2" CW 3" D GC INSTALL BACKFLOW PREVENTER IN SUPPLY 180461 3PL P080 1 SINK DROP -IN FOR MSSV2 CBS SPOKANE STAINLESS KN26 -5012 SP 1/2" CWF 1 1/2" D W/ DRAINBOARD & GRATE 505824 VD P390 1 10" DIPPERWELL DEEP DRAWN FERGUSON ENTERPRISES INC ZURN Z -826F1 1/2" CW 1 1/2" INDIRECT 357151 3PL P392 1 45 LB ICE BIN FERGUSON ENTERPRISES ZURN Z -82651 1/2" CW /HW 1" INDIRECT 344430 3PL P393 1 WORKSINK 1 /2 "HW 1 1/2" INDIRECT 344429 3PL P395 1 HAND SINK STAINLESS STEEL 1 /2 "HW 1 /2 "CW 1 1/2" DIRECT 344428 3PL FAUCETS P354 1 FAUCET HANDSINK ZURN FERGUSON ENTERPRISES ZURN Z7440 -WF 1/2" CW /TW AT RESTROOM HAND SINK 190076 3PL P355 1 WORKSINK FAUCET PRE -RINSE COMPONENT HARDWARE GROUP KN53- 1000 -BR 208V/10 5KW 1/2" CW /HW INDIRECT AT WORKROOM COMPARTMENT SINKS 181032 3PL P356 1 FAUCET & BRACKET FOR MOP FERGUSON ENTERPRISES ZURN 2- 1996 -SF 1/2" CW /HW INCLS INTGRL VACUUM BRKER & STP CHK VLVS 277679 3PL P360 1 FAUCET 14" WORKROOM ADD -ON COMPONENT HARDWARE GROUP KN55-7014 183203 3PL P367 1 FAUCET BACKBAR PITCHER RINSER FERGUSON ENTERPRISES ZURN Z -825F1 1/2" CW GC INSTALL BACKFLOW PREVENTER IN SUPPLY 182121 3PL P376 1 FAUCET 12" GLASS FILLER COMPONENT HARDWARE KN26 -5012 SP 1/2" CWF 185897 3PL P377 1 FAUCET LABORATORY HOT & COLD FERGUSON ENTERPRISES INC ZURN Z -826F1 1/2" CW /HW 189613 3PL P380 1 FAUCET BACKBAR WORKSINK FERGUSON ENTERPRISES ZURN Z -82651 1/2" CW /HW 194916 3PL ACCESSORIES P804 3 FLOOR SINK HALF WIRE GRATE FERGUSON ENTERPRISES ZURN 180466 3PL P806 1 ELECTRICAL WATER HEATER A.O. SMITH DEN52 208V/10 5KW 3/4" CW /HW INDIRECT 50 GAL CAP./ 2EA 5KW NON - SIMULTANEOUS ELEMENTS GC 1" WATER SUBMETER W /REMOTE READOUT (TYPE PER LL REQUIREMENTS). SEATING PLUMBING SUPPLY PLAN 2 3 12 PLUMBING PLAN KEY NOTES 0 1" CW TO WATER HEATER & 1" HW FROM WATER HEATER. INSTALL 3/4" TEMPERTATURE MIXING VALVE ABOVE HOT WATER TANK. ® WATER HEATER AS SPECIFIED AND IN COMPLIANCE WITH APPLICABLE CODES AND ORDINANCES. CONTRACTOR TO ENSURE DIMENSIONS OF THE HEATER ALLOW INSTALLATION ABOVE THE MOP SINK. REFER TO WATER HEATER DETAIL. EXTEND WATER HEATER THRU CEILING IF NEEDED. Q 1/2" HW & CW TO FAUCET AT MOP SINK: PROVIDE APPROVED BACKFLOW PREVENTION DEVICE ON SERVICE FAUCET AS NEEDED. CAULK AND SEAL BACK OF SINK TO WALL. O4 3/4" CW TO WATER FILTER & 3/4" CWF FROM WATER FILTER. PLUMBING CONTRACTOR TO FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ACTIVATION PROCEDURES FOR FILTERS. INSTALL ASSEMBLY ON WALL. REFER TO WATER FILTER DETAIL. a 1/2" HW & CW TO FAUCET & SPRAY AT COMPARTMENT SINK AND AT WORK SINK. CAULK AND SEAL BACK OF SINK TO WALL. Q 3/4" HW TO SANITIZER. INSTALL SHUT -OFF WITH 3/4" MALE HOSE -END FITTING AT 18" A.F.F. UNDER COMPARTMENT SINK. SHUT -OFF TO INCLUDE PRESSURE REDUCING VALVE, PRESSURE GAUGE (SET @ 20 PSIG, +1- 5 PSIG), LINE STRAINER, AND SHOCK ARRESTOR IN WALL. CONNECT SANITIZER TO HW SUPPLY WITH 72" LONG BRAIDED STAINLESS STEEL HOSE. 1/2" CWF TO ICE MACHINE. REDUCE TO 3/8" AT MACHINE. 1/2" TW & CW TO HANDSINK. 1/2" CWF TO COFFEE BREWER. INSTALL SHUT -OFF IN CABINET @24" AFF REDUCE TO 3/8 " AT UNIT. 0 Q 0 1/2" CWF TO ESPRESSO MACHINE. CONNECT 3/8" BRAIDED STAINLESS STEEL HOSE FROM SHUT -OFF TO ESPRESSO MACHINE WATER INLET. 1/2" CW TO DIPPERWELL FAUCET. 3/8" CWF TO HOT TAP. REDUCE TO 1/4 " AT UNIT. 3/8" CWF TO WATER TOWER FAUCET LOCATED IN WATER STATION. KEY NOTE NOT USED. KEY NOTE NOT USED. 3/4" CW STUB -OUT THRU WALL W /BALL SHUT -OFF VALVE. 3/4" CWF STUB -OUT THRU WALL W /BALL SHUT-OFF VALVE. KEY NOTE NOT USED. VERIFY BACKFLOW PREVENTER REQUIREMENTS OF EQUIPMENT & MAIN WATER SERVICE TO STARBUCKS WITH INSPECTOR BEFORE BID. BACKFLOW PREVENTERS SHALL BE FURNISHED, INSTALLED, & INSPECTED PER CODE (NOT NECESSARILY SHOWN). 20 1/2" CW TO PITCHER RINSER SINK FAUCET, F &I BACKFLOW PREVENTERS PER AHJ REQUIREMENTS & PER CODE. F &I PRESSURE REDUCING VALVE IF PRESSURE WITHIN STARBUCKS EXCEEDS 65PSI. KEY NOTE NOT USED. KEY NOTE NOT USED. SEE SHEET P3.0 FOR TAG AND LOCATION. TIE INTO LANDLORD PROVIDED 1» DOMESTIC WATER SERVICE. VERIFY LOCATION AND REQUIREMENTS ON SITE BEFORE BID. 26 RUN ALL PIPING CONCEALED (TYP), • let • MAR 042008 PERMIT CENTEh STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STAREUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL. COM REV DATE JC DESCRIPTION STARBUCKS COFFEE PROJECT: SOUTHCENTER 11 806 SOUTHCENTER BLVD #1310 oo Or-c; rn COUNTY: KING COUNTY PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH DAN PURAVET SHEET TITLE PLUMBING SUPPLY PLAN 8t SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P2.0 P804 P034 P392 3X2 ABS HUB LOCATE TO SID UC REFER 0 0 P821 00 P036 Ts C a. an ur.rrs� RIESOM IRO l_I.t►_ + 3 "GW Q wei r O idir O 1 A til pm I- -I DRAIN I H r \) SIDE OF P080 2" CV Mae rIl IBACKBAR -111 - -2"V- - -FLT 3 "GW -2 "V- t 1 0 0 GOO 0 • (ALL TYPICAL) folarials 51/ SLAB ON GRADE - EXISTING GRADE BEAMS AND PILE CAPS BELOW SLAB (TYPICAL; NOT ALL SHOWN). DO NOT PENETRATE /CUT THESE EXISTING STRUCTURAL ELEMENTS. (CONFIRM REQUIREMENTS FOR CUTTING, BACKFILL AND PATCHING SLAB WITH LANDLORD'S ENGINEER). PIPING SHALL BE ROUTED BELOW OR AROUND THESE ITEMS AS NEEDED. SEATING 4 "W (EX) SALES 1 021 I )--2-1/2"V 13- -3"V- L -�- 2 "V • (39DFU) 4 "W (EX)- S (6DFU) CONNE� WASTE LI LOCATI�N (CONFIRM 'rc) P804 P034 PLUMBING WASTE/ VENT PLAN 4" GW (EX i— — T WORKROOM 0 17 RECESSED ELECTRICAL PANELS CONNECT TO EXIST. GREASE WASTE (CONFIRM LOCATIONS ETC) (3 DFU) AIR HANDLER ABOVE CEILING PLUMBING GENERAL NOTES: PLUMBING KEY NOTES • F &I A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. Q FOR FULL SCHEDULES AND COMPLETE LISTING SEE SCHEDULES. CONFIRM ALL QUANTITIES WITH PLAN. O PLUMBING CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. 0 COORDINATE WITH ELECTRICAL CONTRACTOR FOR POWER CONNECTION TO ALL PLUMBING Q EQUIPMENTNOTED. . DIMENSIONS ARE TO FACE UNLESS OTHERWISE 0 ALL INDIRECT DRAIN LINES SHALL BE ROUTED WITHOUT DIPS OR SAGS TO TERMINATE WITH AN AIR GAP INTO AN APPROVED INDIRECT WASTE RECEPTOR. cG REFER TO DETAILS FOR FURTHER REQUIREMENTS. NOTE: t ALL BELOW GRADE PIPES SHALL BE SUPPORTED FROM SLAB WITH STAINLESS STEEL HANGERS PER CODE AND LANDLORD REQUIREMENTS. 2. SEE UNDERSLAB CONDUIT PLAN FOR ADDITIONAL UNDERSLAB ITEMS. 3. ALL INDIRECT DRAINS SHALL RUN SEPARATELY FROM FIXTURE TO INDIRECT DRAIN RECEPTOR AND SHALL TERMINATE WITH AN AIR GAP PER CODE UNLESS INDICATED OTHERWISE. 3/4" PRESSURE RELIEF FROM WATER HEATER TO MOP SINK. 1" INDIRECT DRAIN FROM WATER HEATER DRIP PAN TO MOP SINK. 3" GREASE WASTE /2 "V FROM MOP SINK. 2" DIRECT DRAIN FROM COMPARTMENT SINK TO GREASE WASTE. COORD. W/ AHJ PRIOR TO BID & F &I INDIRECT IF NEEDED. 1 -1/2" INDIRECT DRAIN FROM DISHWASHER TO FLOOR SINK. (DO NOT CONNECT TO GREASE WASTE. (SEE DETAIL) (2) 3/4" INSULATED INDIRECT DRAINS FROM ICE MACHINE TO FLOOR SINK, DO NOT INTERCONNECT DRAINS. INSTALL FEMALE PIPE THREAD FROM ESPRESSO MACHINE DRAIN TRAY TO INDIRECT HUB DRAIN. 2" INDIRECT LINE FROM HUB DRAIN TO FLOOR SINK. 1" INDIRECT DRAIN FROM DIPPER WELL TO FLOOR SINK. 1 -1/2" INDIRECT INSULATED DRAINLINE FROM ICE BIN DROP TO FLOOR SINK. 1 -1/2" INDIRECT DRAIN FROM WATER STATION DRAIN BOARD TO FLOOR SINK, 3" WASTE /2 "V FROM FLOOR SINK. 2" GREASE WASTE /1 -1/2 "V FROM SINK. NUMBER NOT USED. 3" GREASE WASTE /2 "V FROM FLOOR SINK. TRAPPED PRIMARY & AUX, CONDENSATE INDIRECT DRAINS FROM AIR HANDLING UNIT TO FLOOR SINK. VERIFY SIZE & LOCATION OF DRAIN BASED UPON EQUIPMENT REQUIREMENTS AND PLACEMENT. F &I CLEANOUTS AS NEEDED. FLOOR CLEAN OUT, MATCH SIZE TO DRAIN LINE. CONFIRM THAT THESE LOCATIONS ARE CORRECT & NOT AS SHOWN ON SHELL DWGS. NUMBER NOT USED. 1" INDIRECT DRAIN FROM CBS DRAINBOARD TO FLOOR SINK. 2 "GREASE WASTE /1 -1/2 "V FROM PITCHER RINSER SINK. IF DIRECT NOT ALLOWED, PROVIDE 1 -1/2" INDIRECT DRAIN. VERIFY WITH AHJ BEFORE BID. F &I ANY NEEDED INDIRECT PIPING FROM BACKFLOW DEVICES TO FLOOR SINKS (TYP)(NOT SHOWN). F &I ALL NEEDED INDIRECT PIPING (NOT NECESSARILY SHOWN). NUMBER NOT USED. FIELD LOCATE EXISTING VTR & CONNECT TO IT PER CODE. 3/4" INDIRECT DRAIN FROM WATER FILTER EQUIPMENT TO MOP SINK OR FLOOR SINK. EVEN THOUGH INDIRECT PIPING I5 SHOWN AT THIS LOCATION, IT IS NOT SHOWN ELSEWHERE. ALL P -TRAPS (WITH INTEGRAL UNION) & TAIL PIECE TO BE TYPE ABS UP TO AND INCLUDING THREADED COUPLING TO BASKET STRAINERS AT ALL SINKS. F &I WALL CLEANOUTS AT ALL SINKS AND AS NEEDED (NOT SHOWN- TYPICAL). CODE REVIEWED FOR AN CE NFPA 70 - NEC MAR 2 7 2008 City Of Tukwila BUILDING DIVISION RD, rffve: MAR 0 4 2008 PERMIT UEN ; L EXPIRES f STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23@AOL.cOM REV DATE JC DESCRIPTION STARBUCKS COFFEE �E� SOUTHCENTER 11 806 SOUTHCENTER BLVD #1310 TU KWI LA, VITA 98188 COUNTY: KING COUNTY PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01 /28/08 JOHN BEEBE CHRIS RENSCH DAN PURAVET SHEET TITLE PLUMBING WASTE /VENT PLAN SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER P3.0 GENERAL ELECTRICAL NOTES: TELEPHONE SYSTEM NOTES: SECURITY SYSTEM NOTES: DSL /FRAME RELAY NOTES: ELECTRICAL LEGEND NOTE: "CONTRACTOR" MEANS "ELECTRICAL CONTRACTOR" (SEE LANDLORD SCOPE OF WORK ON THIS SHEET TO DETERMINE IF WORK IS BY LANDLORD'S OR STARBUCKS ELECTRICAL CONTRACTOR) WHEN REFERENCED ANYWHERE IN THE ELECTRICAL CONSTRUCTION DOCUMENTS. "AHJ" MEANS AUTHORITIES HAVING JURISDICTION, "NEEDED" MEANS ITEMS CALLED OUT IN THE CONTRACT DOCUMENTS PLUS ANY OTHER ITEMS TO MAKE A COMPLETE AND OPERABLE SYSTEM THAT ARE NOT CALLED OUT. ® THE INTENT OF THE SPECIFICATIONS AND THE DRAWINGS IS TO PROVIDE A COMPLETE AND FULLY OPERATIONAL ELECTRICAL SYSTEM. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL LABOR, MATERIAL AND EQUIPMENT NECESSARY TO COMPLETE THE ELECTRICAL WORK (SEE ELECTRICAL SPECIFICATIONS). ® THE ELECTRICAL CONTRACTOR SHALL THOROUGHLY EXAMINE ALL AREAS WHERE EQUIPMENT, CONDUIT, AND WIRING WILL BE INSTALLED AND WILL REPORT ANY CONDITION THAT PREVENTS THE PROPER INSTALLATION OF THE ELECTRICAL WORK. EQUIPMENT AND MATERIALS SHALL CONFORM WITH APPROPRIATE PROVISIONS OF NEC, WAC, ASTM, UL, ETL, NEMA, ANSI, AND OTHER APPLICABLE AGENCY AS THEY APPLY TO EACH INDIVIDUAL UNIT OR •ASSEMBLY. ® ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALL APPLICABLE STATE AND LOCAL CODES AND ORDINANCES AND PER REQUIREMENTS OF THE A.H.J. IN CASE OF CONFLICT BETWEEN THE DRAWINGS SPECIFICATIONS AND THE CODES AND ORDINANCES (OR A.H.J.), THE MOST STRICT STANDARD ON THE OPINION OF THE ENGINEER) SHALL APPLY. THE ELECTRICAL CONTRACTOR SHALL SATISFY CODE REQUIREMENTS, A.H.J. AND THE CONTRACT DOCUMENTS AS A MINIMUM STANDARD WITHOUT ANY EXTRA COST. ® THE ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL WORK WITH OTHER TRADES. THE ARCHITECTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER ALL OTHER DRAWINGS. DO NOT SCALE DISTANCES OFF THE ELECTRICAL DRAWINGS; USE ACTUAL BUILDING DIMENSIONS. ® ALL ELECTRICAL SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. BALANCE ALL BRANCH CIRCUIT LOADS BETWEEN THE PHASES OF THE SYSTEM TO WITHIN 10% OF THE HIGHEST PHASE LOAD IN EACH PANELBOARD. ® THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEENERGIZING CIRCUITS IN DEMOLITION AREAS TO INSURE A SAFE CONDITION. ELECTRICAL DEVICES AND ASSOCIATED WIRING LOCATED WITHIN THE DEMOLITION AREA THAT WILL NO LONGER BE USED SHALL BE REMOVED AND PROPERLY DISPOSED OF AT CONTRACTORS EXPENSE UNLESS OTHERWISE NOTED. ® THE ELECTRICAL CONTRACTOR SHALL SCHEDULE ALL ELECTRICAL SYSTEM(S) OUTAGES WITH THE GENERAL CONTRACTOR AND LANDLORD AT LEAST 24 HOURS IN ADVANCE. UNLESS APPROVED OTHERWISE ALL OUTAGES SHALL OCCUR BETWEEN 11:OOPM AND 5:OOAM. ® AT START OF CONSTRUCTION, GNOC (GLOBAL NETWORK OPERATIONS CENTER) WILL ORDER PHONE SERVICE. CM TO SUBMIT FORM VIA EMAIL TO THE GNOC GROUP AT GNOC@STARBUCKS.COM © STORES REQUIRE A MINIMUM OF FIVE OR SIX(SEE BELOW) PHONE LINES TERMINATED AT THE DEMARC BOARD IN THE BACK OF HOUSE NEAR THE MANAGER'S DESK AND THE TECHNOLOGY RACK. PHONE LINE ASSIGNMENTS CAN BE FOUND ON THE STORE DELIVERY SCHEDULE. THEY ARE TO BE TERMINATED AND LABELED IN THE FOLLOWING ORDER AND USE. LINE #1 — VOICE LINE FOR MAIN LISTED PHONE NUMBER AND ALARM PANEL. ROUTE THE CABLE FROM DEMARC TO RJ31X JACK ADJACENT TO INTERACTIVE SECURITY ALARM PANEL. LABEL JACK .AS "V1 —VOICE LINE W/telephone number /ALARM PANEL ". EXTEND CABLING FROM RJ31X TO THE MANAGER'S DESK AND EACH BARISTA PHONE LOCATION WITH AN RJ11 JACK. LINE #2 — VOICE LINE FOR ROLLOVER PHONE NUMBER. ROUTE CABLE FROM DEMARC TO A RJ11 JACK LOCATED AT THE MANAGER'S DESK. LABEL JACK AS "V2 —VOICE LINE W /telephone number ". LINE #3 — DEDICATED LINE FOR DIAL UP MODEM FOR THE MANAGER'S PC WORKSTATION. ROUTE CABLE FROM DEMARC TO A RJ11 JACK ADJACENT TO THE BOH TECHNOLOGY RACK. LABEL JACK AS "MODEM LINE W /telephone number ". SEE DETAIL. LINE #4 — DEDICATED LINE FOR THE INTERACTIVE SECURITY SYSTEM. ROUTE CABLE FROM DEMARC TO A RJ11 JACK ADJACENT TO THE DIGITAL SECURITY RECORDER ON THE BOH TECHNOLOGY RACK. LABEL JACK AS "AUDIO LINE W /telephone number ". SEE DETAIL. LINE #5 — DEDICATED LINE FOR THE VIDEO MODULE IN THE SECURITY ALARM PANEL. ROUTE CABLE FROM DEMARC TO A RJ11 JACK ADJACENT TO THE SECURITY ALARM PANEL. LABEL JACK AS "VIDEO LINE W /telephone number ". SEE LAN /POWER /SECURITY SYSTEM DIAGRAM. LINE #6 — CONFIRM IF 6TH LINE IS NEEDED WITH C.M. FOR INTERAC DEBIT SYSTEM. © COORDINATE THE WORK OF THIS SECTION WITH THE REQUIREMENTS OF STARBUCKS COFFEE COMPANY'S SECURITY SYSTEM INSTALLER. ® USING PHONE NUMBER ASSIGNMENT FROM THE STORE DELIVERY SCHEDULE, THE GC WILL CROSS CONNECT THE VOICE TELEPHONE LINES FROM THE PHONE COMPANY (LEC) INTERFACE (66 BLOCK) TO THE 110 HARDWARE IN THE MPOE. THE DATA CABLING VENDORS WILL CROSS CONNECT THE DSL /FRAME RELAY CIRCUITS, Q STARBUCKS CONTRACTS DIRECTLY WITH SECURITY VENDOR TO SUPPLY & INSTALL THE SECURITY SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF SECURITY SYSTEM FOR TWO TIMES: ROUGH —IN PRIOR TO DRYWALL INSTALLATION AND FINAL TRIM PRIOR TO STORE TURNOVER. SECURITY VENDOR REQUIRES A MINIMUM TWO WEEKS LEAD TIME FOR EACH INSTALLATION. SECURITY VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. SECURITY VENDOR THE DIEBOLD COMPANY CONTACT: DIEBOLD PROJECT MANAGEMENT, STARBUCKS NEW STORES PHONE: 206- 318 -6688 EMAIL: starbucksWieboid,com ®A THE DSL /FRAME RELAY VENDOR WILL INSTALL THE IN —HOUSE WIRING AND RJ45 JACK FOR THE DSL /FRAME RELAY SERVICES. THE CAT5 CABLE PINNED TO POSITIONS 9 ''12 AT THE 110 BLOCK SHALL BE EXTENDED AND TERMINATED WITHIN TWO (2) FEET OF THE TECHNOLOGY (OR IT) RACK INTO A J —BOX ATTACHED TO THE WALL CONTAINING AN RJ45 JACK. THE RJ45 JACK SHALL BE LABELED "DSL /FRAME RELAY LINE ". POS / DATA LINE NOTES: COMMUNICATION SYSTEMS NOTES: T- MOBILE / TI NOTES: ® THE CAT5 CABLE PINNED TO POSITION 13 -16 AT THE 110 BLOCK SHALL BE EXTENDED AND TERMINATED WITHIN TWO (2) FEET OF THE TECHNOLOGY (OR IT) RACK, INTO A J—BOX ATTACHED TO THE WALL, CONTAINING AN RJ48C JACK. THE RJ48C JACK SHALL BE LABELED TMOBILE /T1 �� . ®A PROVIDE FOUR (4) CAT5 (WHITE) COMMUNICATION CABLES TO THE SPACE. ® FOUR ((4) CAT5 CABLES ARE DEDICATED TO STORE OPERATIONS /COMMUNICATIONS. a THE GC MUST INSTALL 110 HARDWARE (MINIMUM SIZE: 25pr) IN BOTH THE MPOE AND BOH. THE 110 HARDWARE IN THE BOH SHOULD BE PLACED ON THE BACKBOARD (PARTS RECOMMENDED: AVAYA 110DW 2-25 — MFG PART# 107256653). THE SERVICE LOOP (30 FOOT) CAN BE SHORTENED TO ACCOMODATE THE PLACEMENT OF THE 110 HARDWARE. ALL FOUR (4) OF THE CAT5 CABLES MUST BE PUNCHED DOWN TO THE 110 HARDWARE AT THE MPOE AND BOH, TONED, TESTED AND LABELED AS INDICATED IN THE TABLE BELOW: CABLE PAIRS /POSITION LABELED 1 2 3 4 9 ,-12 13,-16 V1, V2, V3, V4 V5, V6, V7, V8 DSL/FRAME RELAY T— MOBILE/T1 THE GC SHOULD PERFORM THE PUNCH DOWN AT THE MPOE AND THE BOH PER THE FOLLOWING 568b IN— BUILDING CAT5 CABLING STANDARD: PIN WIRE COLOR 1 WHITE /ORANGE 2 ORANGE 3 WHITE /GREEN 4 BLUE 5 WHITE /BLUE 6 GREEN 7 WHITE BROWN 8 BROWN ® STARBUCKS CONTRACTS DIRECTLY WITH THE DATA CABLING VENDOR TO SUPPLY AND INSTALL CATEGORY 5 LAN CABLE AND CONNECTORS FOR THE POS SYSTEM. CONTRACTOR TO SCHEDULE INSTALLATION OF DATA CABLING WITH DATA CABLING VENDOR. DATA CABLING VENDOR REQUIRES A LEAD TIME FOR INSTALLATION. DATA CABLING VENDOR WILL COORDINATE REGIONAL INSTALLERS. ALL ADDITIONAL EXPENSES INCURRED DUE TO THE CONTRACTOR'S FAILURE TO SCHEDULE ACCORDINGLY WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. © AT THE START OF CONSTRUCTION, STARBUCKS CM SCHEDULES DELIVERY OF CASH REGISTER /MANAGER'S WORKSTATION EQUIPMENT AND INSTALLATION BY A DATA CABLING TECHNICIAN FOR TWO DAYS PRIOR TO CONSTRUCTION END. CONTRACTOR TO VERIFY DELIVERY SCHEDULE TWO WEEKS PRIOR TO DELIVERY AND INSTALLATION DATE. EQUIPMENT I5 SHIPPED DIRECTLY TO THE STORE, CONTRACTOR TO ACCEPT POS EQUIPMENT DELIVERY, DO NOT REFUSE DELIVERY. ®C DATA CABLING TECHNICIAN TO PROVIDE ALL CATEGORY 5 LAN CABLING AND CONNECTIONS TO ALL DESIGNED AND FUTURE CASH REGISTER LOCATIONS, AND MANAGER'S WORKSTATION. ® DATA CABLING TECHNICIAN TO REMOVE PACKAGING, INSTALL AND TEST CASH REGISTERS, CASH DRAWERS AND .MANAGER'S WORKSTATION. ® CONTRACTOR RESPONSIBLE FOR COORDINATION OF PHONE /DSL LINE INSTALLATION PRIOR TO DATA CABLING VENDOR'S WORK. ®F INTERAC PAYMENT METHOD (IF NEEDED) TO BE INSTALLED BY DATA CABLINE VENDOR. COORDINATE EXACT LOCATION FOR ELECTRICAL /PHONE LINES WITH PROJECT MANAGER. POS DELIVERY AND INSTALLATION CONFIRMATION CONTACT: NEWSTORE @STARBUCKS.COM FOR CURRENT DATA CABLING VENDOR CONTACT: NEWSTORRSTARBUCKS.COM MUSIC SYSTEM NOTES: $3 $M $K A 0 E D.L. U. 0.N. LL O.C.P. OR SWITCH THREE WAY SWITCH MOTION (OCCUPANCY) SENSOR SWITCH KEYED SWITCH SWITCHBANK SEE DETAIL ON E3.0 TELEPHONE THERMOSTAT THERMOSTAT SENSOR DIMMER DAY LIGHT ZONE SWITCHED SEPARATELY TIME CLOCK UNLESS OTHERWISE NOTED LANDLORD OVER CURRENT PROTECTION EXIT SIGN NL E F &I AHJ U.N.O. MDP JUNCTION BOX L.A.N. RECEPTACLE RECEPTACLE; 110 DUPLEX RECEPTACLE: 110 DEDICATED GFI RECEPTACLE: 110 DUPLEX RECEPTACLE: 110 QUAD RECEPTACLE: 208V OR 220V GROUNDING ELECTRODE CONNECTION NIGHTLIGHTING 24 HR /DAY EXISTING FURNISH & INSTALL AUTHORITIES HAVING JURISDICTION UNLESS NOTED OTHERWISE MAIN DISTRIBUTION PANEL DISCONNECT SWITCH, FUSED, IF NEEDED CONCEALED RACEWAY: CONTRACTOR TO F &I APPROPRIATE QUANTITY OF CONDUCTORS BY SUMMING QUANTITIES CALLED OUT IN NOTES. IF NOTE DOES NOT CALL OUT QUANTITIES, F &I 2 #12 CU. MINIMUM PER DEVICE. F &I DEDICATED NEUTRAL FOR ALL GFI CIRCUITS TO PREVENT FALSE TRIPPING. F &I A NEUTRAL FOR PHASE TO PHASE LOADS IF NEEDED FOR CONTROLS OR OTHER REASONS. F &I GROUND WIRE IN ALL PVC CONDUITS (NOT SHOWN). PVC CONDUITS ARE NOT ALLOWED IN MULTI FLOOR BUILDINGS WHERE CONDUIT IS EXPOSED TO AIR OR ABOVE GRADE FOR ANY BUILDING. ® PROVIDE AND INSTALL A COMPLETE WIRING SYSTEM FOR ALL SPEAKERS. CONNECT ALL SPEAKERS TO THE OWNER PROVIDED MUSIC SYSTEM. MOUNT OWNER FURNISHED SPEAKERS. FOLLOW MANUFACTURERS INSTALLATION REQUIREMENTS. ENERGY CODE CALCULATIONS SEE ATTACHED 8 -1/2 "x 11" SHEETS FOR ENERGY CODE CALCULATIONS SCOPE OF WORK NOTE: CONTRACTOR SHALL COORDINATE WITH LANDLORD AND OBTAIN A COPY OF THE TENANT CRITERIA MANUAL /SPECIFICATIONS AND ALL OTHER CONSTRUCTION REQUIREMENT DOCUMENTS FOR THIS PROJECT. CONTRACTOR SHALL BECOME COMPLETELY FAMILIAR WITH LANDLORD REQUIREMENTS /SPECIFICATIONS AND ADHERE TO THEM. LANDLORD'S SCOPE OF WORK: THE FOLLOWING ABBREVIATED SCOPE OF WORK SHALL BE COMPLETED BY THE LANDLORD'S CONTRACTORS AS SPECIFIED IN THE "LANDLORD WORK LETTER — EXHIBIT B AND TENANT CRITERIA MANUAL ". NOT ALL WORK IS NECESSARILY CALLED FOR IN THIS DESCRIPTION OR IN THESE PLANS. REFERENCE THE "LANDLORD WORK LETTER" AND "TENANT CRITERIA MANUAL" FOR A COMPLETE DESCRIPTION OF WORK SCOPE. THE LANDLORD SHALL: 1. FURNISH AND INSTALL (F &I) POWER SERVICE(S) WITH 200 AMPS OF 480V/277V 30, 4W CAPACITY TO STARBUCK'S SPACE INCLUDING ALL METER(S), DISCONNECT(S), CONDUIT(S), WIRE AND MISCELLANEOUS AS SHOWN ON THESE PLANS. TERMINATE SERVICE IN A 200A FUSED SWITCH LOCATED PER THESE PLANS READY TO BE USED FOR TEMPORARY POWER. (STARBUCKS CONTRACTORS TO F &I TRANSFORMERS AND PANELS TO UTILIZE 480V TEMPORARY POWER). 2. LANDLORD TO F &I COMMUNICATION TERMINAL BOARD IN ELECTRICAL ROOM FOR PHONE SYSTEM AND MAKE AVAILABLE A CABLE TRAP IN THE SERVICE CORRIDOR FOR CABLING. 3. F &I JUNCTION BOX WITHIN SPACE WITH CONDUIT FEED FOR FIRE ALARM SYSTEM (CONFIRM SCOPE). STARBUCKS CONTRACTORS SCO E OF WORK; STARBUCKS CONTRACTORS SHALL BE RESPONSIBLE FULLY OPERATIONAL ALL POWER, FIRE ALARM AND IN ADDITION, INCLUDE LANDLORD'S APPROVED FIRE THIS SPACE. FOR ALL WORK NOT COVERED IN ABOVE LANDLORD'S SCOPE OF WORK TO COMPLETE AND MAKE LIGHTING SYSTEMS. COORDINATE WITH STARBUCKS GC. ALARM CONTRACTORS COST TO DESIGN, FURNISH AND INSTALL THE FIRE ALARM SYSTEM FOR LANDLORD REQUIREMENTS THE FOLLOWING LANDLORD REQUIREMENTS /SPECIFICATIONS IS AN ABBREVIATED OVERVIEW. IT IS THE CONTRACTORS RESPONSIBILITY TO OBTAIN, BECOME COMPLETELY FAMILIAR, AND ADHERE TO ALL OF THE LANDLORD'S REQUIREMENTS. WHERE LANDLORD REQUIREMENTS ARE MORE STRINGENT THAN SHOWN IN THESE PLANS, LANDLORD REQUIREMENTS SHALL GOVERN. 1. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION OR CORE DRILL AND /OR POSTIONING OF ANY EQUIPMENT ON THE ROOF, ALL THE PROPOSED LOCATIONS AND /OR PENETRATIONS SHALL MATCH LOCATIONS AS INDICATED ON LANDLORD — APPROVED PLANS AND APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 2. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGISHER (MINIMUM SIZE 2A:20BC), WHEREVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR THE LEAST ONE (1) HOUR AFTER COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE CITY OF TUKWILA FIRE DEPARTMENT. 3. FLEXIBLE CONDUIT CANNOT BE USED AS COMMON ROUTING FOR WIRES. IT IS LIMITED TO WITHIN CASEWORK AND FINAL CONNECTION OF EQUIPMENT AND LIGHT FIXTURES (4 FT. MAX). 4. ALL WIRING SHALL BE IN CONDUIT WITH TYPE PER CODE. NO MC CABLE (ETC.) IS ALLOWED. 5. CONDUIT RUNS SHALL BE SEPARATED BY 3" WHEREVER THEY RUN NEXT TO OR CROSS WATER OR GAS LINES. 6. ALL CONDUIT HANGERS, CLAMPS, LIGHT FIXTURE SUPPORT, ETC. SHALL BE MADE TO BAR JOISTS AND BEAMS. CONDUITS SHALL NOT BE SUPPORTED FROM ANY OTHER CONDUIT, DUCT, PIPE, ETC. 7. CAULK AROUND ELECTRICAL BOXES IN DEMISING WALLS TO REDUCE NOISE TRANSMISSIONS. 8. PROVIDE LOC —ON DEVICES ON PANEL CIRCUIT BREAKERS FOR EXIT, EMERGENCY LIGHT, AND FIRE /ALARM SYSTEMS. 9. TENANT'S ELECTRICAL CONTRACTOR SHALL F &I IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD (CONFIRM REQUIREMENTS). MAR 04 2008 PERMIT CENTE.I- STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELT. AS STARBUCKS NAME AND LOGO, TRADEMARKS MD DESK IS ARE THE EX•LUSI4E PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT 15 STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COM REV DATE JC DESCRIPTION STARBUCKS COFFEE Q (r7 rx W Z z 0 0 15 O D cry 0 c0 VJ 00 U LU 0 a co 00 COUNTY: KING COUNTY PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL SPECIFICATIONS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E1.0 NOTES CFI GFI PANEL A VOLTAGE: 208V/120V 3PH, 4W MAIN BREAKER: 125A FED FROM: PANEL 'H' VIA TRANSFORMER AIC RA11NG: 10K BUS: 125 AMP LOCATION: WORKROOM SERVES TYPE LOAD CKT BRKR CKT NO. CKT LOAD PHASE LOADS CKT LOAD CKT NO. CKT BRKR TYPE LOAD SERVES AMP POLE A B C AMP P011 ESPRESSO MACHINE K 40/2 1 3,300 3,660 360 2 20/1 R PHONEBOARD GENERAL LIGHTS K 3 3,300 460 4,500 t360 L200 4 20/1 R MANAGERS DESK ESPRESSO MACHINE K 40 /2 5 3,300 4,500 1,200 6 20/1 R MANAGERS DESK POS MIS /SCALE K 7 3,300 3,800 1,560 4,510 500 8 20/1 NC MANAGERS DESK DISHWASHER K 50 /2 9 3,952 9 3,952 2,016 3,040 10 20 /1 10 SPARE K K 11 3,952 20 /1 11 3,952 12 20 /1 2,950 SPARE SPARE K 20/1 13 R 1,356 13 90 1,356 14 20/1 K HOT TAP @ BARISTA FOODCASE LIGHTS L 15/1 15 290 20 /1 1,130 840 16 15 /1 K UC REFER @ BARISTA FOODCASE K 20/2 17 1,310 20 /1 17 2,150 840 18 15/1 K UC REFER @ BARISTA K 19 1,310 2,090 19 500 780 20 20 /1 K FRAPP /LABELER /WARMERS SPARE CL 20 /1 21 K 15 /1 840 1,200 840 22 15/1 K UC REFER SPARE K 20 /1 23 K 20 /2 23 840 840 24 15 /1 K UC REFER SPARE K 20 /1 25 K 840 25 1,435 840 26 15 /1 K UC REFER SALES AREA RECS R 20/1 27 1,080 20 /1 1,260 180 28 20/1 K LABELER REC. IN WORKROOM R 20 /1 29 180 29 1,680 1,500 30 20 /1 K GRINDER CU ROOFTOP UNIT REC R 20 /1 31 180 1,380 31 1,200 32 20 /1 L SIGNAGE WORKROOM REC R 20 /1 33 1,200 1,700 500 34 20 /1 R MISC. LIGHTS / RECS FOR AHU SPARE 20 /1 35 35 550 5 3 1 EN�FtA Il�,,�G :r„,� 1� SPARE 20 /1 37 400 37 400 38 20/1 N AHU SMOKE DETECTOR SPARE ���` SPARE 20 /1 39 0 40 20/1 SPARE 20 /1 41 BLANK 0 42 20 /1 0 SPARE PHASE PHASE TOTAL KITCHEN LOAD = TOTAL LIGHTING LOAD = TOTAL NON -CONT. LOAD = TOTAL RECEPTACLE LOAD = TOTAL CON11NUOUS LOAD = TOTAL HVAC LOAD = LARGEST MOTOR LOAD = TOTAL KVA = TOTAL AMPS = CONNECTED WATTS = CONNECTED AMPS = CONN. DEMAND KVA FACTOR 13,526 13,382 13,672 LOAD TYPE KEY: K = KITCHEN LOAD L = LIGHTING LOAD NC = NON - CONTINUOUS LOAD R = RECEPTACLE LOAD CL = CONTINUOUS LOAD H = HVAC LOAD LM = LARGEST MOTOR LOAD /120V 3PH, 4W 113 112 114 = = = - = = = - = 1 DEMAND KVA UNDER 10KW AMPS©208V 31.74 2.04 0.90 5.90 0.00 0.00 0.00 X 0.65 X 1.25 X 1.0 X 1.0 X t25 X 1.0 X 1.25 20.63 2.55 0.90 5.90 0.00 0.00 0.00 40.6 30.0 CONN. DEMAND 113 AMPS 83 NOTES: GFI - F &I GFI BREAKERS AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO LIMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). COORDINATE WITH LANDLORD. PANEL SCHEDULE 'A' NOTES GFI GFI GFI GFI GFI GFI GFI GFI PANEL B VOLTAGE: 208V/120V 3PH, 4W MAIN BREAKER: 125A FED FROM: PANEL 'H' VIA TRANSFORMER AIC RATING: 10K BUS: 125 AMP LOCATION: WORKROOM SERVES TYPE LOAD CKT BRKR CKT NO. CKT LOAD PHASE LOADS CKT LOAD CKT NO. CKT BRKR TYPE LOAD SERVES AMP IPOLE A B C AMP POLE DISPLAY LIGHTS L 20 /1 1 660 840 180 2 20 /1 NC SAFE GENERAL LIGHTS L 20 /1 3 460 3,000 t360 900 4 20/1 NC POS EQUIPMENT SPARE 20 /1 5 3,460 720 720 6 20/1 NC POS MIS /SCALE BLENDER K 20 /1 7 1,560 4,510 460 2950 8 30 /2 K WARMING OVEN SPARE OUTLET FOR BLENDER R 20 /1 9 90 2,016 3,040 2,016 2,950 10 H K SPARE BLENDER K 20 /1 11 t560 2,016 4,510 2,950 12 30/2 K WARMING OVEN SPARE OUTLET FOR BLENDER R 20 /1 13 90 3,040 2,016 Z950 14 H K SUBFEED TO PANEL 'A' SPARE 60/3 20 /1 15 25,582 2,500 12,200 2,500 16 30 /2 K HOT WATER TANK ROLL -UP GRILLE DOOR R 20 /1 17 500 27,437 3,000 2,500 18 K ROLL -UP GRILLE DOOR R 20 /1 19 500 2,000 11,825 1,500 20 20 /1 CL LCD /SERVER REACH -IN REFER K 15 /1 21 1,200 106 5,300 119 4,100 22 50 /2 K TWIN BREWER ICE MACHINE K 20 /2 23 1,435 112 AMPS 86 5,535 4,100 24 K K 25 1,435 1,435 26 BLANK SPARE 20 /1 27 0 28 BLANK BLANK 29 0 30 BLANK BLANK 31 0 32 BLANK BLANK 33 0 34 BLANK BLANK 35 0 36 BLANK BLANK 37 0 38 BLANK BLANK 39 0 40 BLANK BLANK 41 0 42 BLANK PHASE TOTAL KITCHEN LOAD = TOTAL LIGHTING LOAD - TOTAL NON -CONT. LOAD = TOTAL RECEPTACLE LOAD = TOTAL CONTINUOUS LOAD - TOTAL HVAC LOAD = LARGEST MOTOR LOAD = TOTAL KVA = TOTAL AMPS = CONNECTED WATTS = PHASE CONNECTED AMPS = CONN. DEMAND KVA FACTOR 11,825 12,200 13,765 LOAD TYPE KEY: K = KITCHEN LOAD L = LIGHTING LOAD NC = NON-- CONT1N000S LOAD R = RECEPTACLE LOAD CL = CONTINUOUS LOAD H = HVAC LOAD LM = LARGEST MOTOR LOAD /120V 3PH, 4W 99 102 115 = - = = - = = = = DEMAND KVA UNDER 10KW AMPS 0208V 32.19 1.12 1.80 1.18 1.50 0.00 0.00 X 0.65 X 1.25 X 1.0 X 1.0 X 1.25 X 1.0 X t25 20.92 1.40 1.80 1.18 1.88 0.00 0.00 37.8 27.2 CONN. DEMAND 105 AMPS 78 NOTES: GFI - F &I GFI BREAKERS AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUCTION. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO LIMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). COORDINATE WITH LANDLORD. NTS NOTES PANEL H VOLTAGE: 480V/277V 3PH, 4W MAIN BREAKER: M.L.O. FED FROM: MAIN ELECTRICAL ROOM AIC RA11NG: 18K BUS: 200 AMP LOCATION: WORKROOM SERVES TYPE LOAD CKT BRKR CKT NO. CKT LOAD PHASE LOADS CKT LOAD CKT NO. CKT BRKR TYPE LOAD SERVES AMP POLE A B C AMP I POLE 20 /1 VAV -1 FAN H 20 /1 1 1,524 1,524 2 SPARE VAV -1 HEATER H 20 /2 3 3,000 3,000 4 20 /1 SPARE H 5 3,000 3,460 460 6 15/2 H AHU -1 SPARE 20 /1 7 460 460 8 H SPARE 20/1 9 2,016 2,016 10 15/3 H CU -1 SPARE 20/1 11 2,016 2,016 12 H SPARE 20/1 13 2,016 2,016 14 H SUBFEED TO PANEL 'A' 60/3 15 13,382 25,582 12,200 16 60 /3 SUBFEED TO PANEL 'B' VIA TRANSFORMER 17 13,672 27,437 13,765 18 VIA TRANSFORMER 19 13,526 25,351 11,825 20 PHASE TOTAL KITCHEN LOAD = TOTAL LIGHTING LOAD = TOTAL NON -CONT. LOAD = TOTAL RECEPTACLE LOAD = TOTAL CONTINUOUS LOAD = TOTAL HVAC LOAD = LARGEST MOTOR LOAD = TOTAL KVA = TOTAL AMPS _._.. = CONNECTED WATTS = PHASE CONNECTED AMPS = CONN. DEMAND KVA FACTOR 29,351 30,598 32,913 LOAD TYPE KEY: K = KITCHEN LOAD L = LIGHTING LOAD NC = NON - CONTINUOUS LOAD R = RECEPTACLE LOAD CL = CONTINUOUS LOAD H = HVAC LOAD LM = LARGEST MOTOR LOAD /277V 3PH, 4W 106 110 119 = - = = = = = = = 1 DEMAND KVA UNDER 10KW AMPS©480V 63.93 3.16 2.70 7.08 1.50 14.49 0.00 X 0.65 X 1.25 X 1.0 X 1.0 X 1.25 X 1.0 X 1.25 41.55 3.95 2.70 7.08 1.88 14.49 0.00 92.9 71.7 CONN. DEMAND 112 AMPS 86 NOTES: GFI - F &I GFI BREAKERS AND DEDICATED NEUTRALS FOR THESE CIRCUITS TO PREVENT FALSE TRIPPING. EQUIPMENT AIC RATINGS SHALL EXCEED THE AVAILABLE FAULT CURRENT. CONTRACTOR SHALL VERIFY AVAILABLE FAULT CURRENT WITH UTILITY PRIOR TO CONSTRUC11ON. SYSTEM SHALL BE SERIES RATED IF NECESSARY TO OMIT SHORT CIRCUIT CURRENT TO BELOW 22,000 AIC (FOR GFI BREAKERS). COORDINATE WITH LANDLORD. PANEL SCHEDULE 'H' NTS NOTES PANEL SCHEDULE 'B' NTS DISCONNECTS AND FUSED SWITCHES THE NOTES GFI GFI GFI - REVIEWED FOR CODE CO NFPA 70 - NEC MAR 2 7 MB LIGHTING City Of Tukwila B ILDING DM : I! N ELECTRICAL SPECIFICATIONS SCOPE PERMITS AND FEES THE ELECTRICAL CONTRACTOR SHALL PROCURE AND PAY FOR ALL PERMITS, FEES AND INSPECTIONS NECESSARY TO COMPLETE THE ELECTRICAL WORK. WARRANTY THE ELECTRICAL CONTRACTOR SHALL UNCONDITIONALLY WARRANT ALL WORK TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF ONE S'Id YEAR FROM THE DATE OF FINAL ACCEPTANCE BY STARBUCKS AND WILL REPAIR OR REPL E ANY DEFECTIVE WORK PROMPTLY AND WITHOUT CHARGE AND RESTORE ANY OTHER EXISTING WORK DAMAGED IN THE COURSE OF REPAIRING DEFECTIVE MATERIALS AND WORKMANSHIP. TEMPORARY POWER THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY ELECTRICAL WIRING FOR CONSTRUC11ON. THE TEMPORARY SERVICE SHALL BE A MINIMUM OF 60 AMPS, SINGLE PHASE, THREE WIRE, 120/208 VOLTS (OR 120/240V IF 120/208V IS NOT AVAILABLE) FUSED AT MAIN DISCONNECT. ALL RECEPTACLES ON THIS TEMPORARY SERVICE SHALL BE PROTECTED BY A GFI BREAKER. MECHANICAL EQUIPMENT ALL FINAL CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE DONE BY THE ELECTRICAL CONTRACTOR. BASIC MATERIALS AND METHODS MATERIALS PROVIDE ALL NEW MATERIAL AND EQUIPMENT UNLESS NOTED OTHERWISE. ALL EQUIPMENT SHALL BE UL APPROVED AND LABELED, OR OTHER APPROVED TESTING ORGANIZATION WHICH HAS ACCEPTANCE BY THE AUTHORITIES HAVING JURISDICTION (AHJ) FOR THE PURPOSE FOR WHICH THEY ARE USED, IN ADDITION TO MEETING ALL REQUIREMENTS OF THE CURRENT APPLICABLE CODES AND REGULATIONS. NO SUBSTITUTION TO MATERIALS SPECIFIED WILL BE ALLOWED UNLESS NOTED OTHERWISE. ALL ITEMS ARE NEW UNLESS OTHERWISE NOTED (UON). CUTTING AND FITTING PERFORM CUTTING, CORING, FITTING, REPAIRING AND FINISHING OF THE WORK NECESSARY FOR THE INSTALLATION OF THE EQUIPMENT OF THIS SECTION. HOWEVER, NO CUTTING OF THE WORK OF OTHER TRADES OR OF ANY STRUCTURAL MEMBER SHALL BE DONE WITHOUT THE CONSENT OF THE STARBUCKS CONSTRUC11ON MANAGER AND LANDLORD. PROPERLY FILL, SEAL, FIREPROOF, AND WATERPROOF ALL OPENINGS, SLEEVES AND HOLES IN SLABS, WALLS, AND CASEWORK. RACEWAYS FUSED SWITCHES HEAVY DUTY TYPE, HORSEPOWER RATED WITH INTERLOCKING COVER. NEMA 1 TYPICAL. OUTDOOR AND WET LOCATION SWITCHES SHALL BE RAINTIGHT TYPE NEMA 3R. ALL SWITCHES SHALL BE LOCKABLE. FUSES IN CIRCUITS RATED AT 600 AMPERES OR LESS SHALL BE UL CLASS RK1 DUAL - ELEMENT, TIME DELAY, CURRENT LIMITING FUSES. FUSES IN CIRCUITS RATED AT 601 AMPERES OR LARGER SHALL BE UL CLASS L TIME - DELAY, CURRENT LIMITING SWITCHES. INSTALL A NEW (U.N.O.) LIGHTING SYSTEM COMPLETE AND FULLY OPERATIONAL AND IN CONFORMANCE WITH CODE AND UL LISTING REQUIREMENTS. CLEAN ALL FIXTURES AT TIME OF JOB COMPLETION UTILIZING MANUFACTURERS APPROVED OR RECOMMENDED CLEANING SOLUTIONS. ALL FIXTURES AND LAMPS ARE SELECTED, APPROVED AND SUPPLIED BY STARBUCKS AS SCHEDULED ON ARCH. SHEETS UNLESS NOTED OTHERWISE. PROVIDE CODE APPROVED WIRING METHODS FOR BRANCH CIRCUITING INDOORS, SUCH AS EMT CONDUIT AND COPPER CONDUCTORS. ALL ABOVE GROUND CONDUITS SHALL BE EMT OR RIGID. PVC CONDUITS ARE NOT ALLOWED IN MULTI FLOOR BUILDINGS WHERE CONDUIT IS EXPOSED TO AIR OR ABOVE GRADE FOR ANY BUILDING. CONDUIT RUNS ON EXTERIOR OF BUILDING SHALL BE CONCEALED AND BE RIGID STEEL CONDUIT WITH WEATHER TIGHT, CORROSION- RESISTANT FITTINGS. SCHEDULE 40 PVC IS ACCEPTABLE WHERE PERMITTED BY CODE AND AHJ, FOR UNDERGROUND RUNS OR CONCRETE ENCASEMENT WHERE NOT EXPOSED TO PHYSICAL DAMAGE. CONDUIT SHALL NOT BE RUN EXPOSED WITHOUT SPECIFIC PERMISSION FROM THE CONSTRUCTION MANAGER. THE MINIMUM SIZE OF CONDUIT SHALL BE 1/2" UNLESS OTHERWISE NOTED. CONDUIT RUNS CONCEALED IN CONCRETE OR UNDERGROUND. SHALL BE 3/4" MINIMUM, UNLESS OTHERWISE NOTED. CONDUIT CONNECTORS SHALL BE DOUBLE LOCKNUT TYPE, UL LISTED AND LABELED, WITH COMPRESSION OR SET SCREW FITTINGS. RIGID CONDUIT SHALL BE HOT DIPPED GALVANIZED. BRANCH CIRCUIT WORK CHASED INTO EXISTING CONSTRUCTION FOR CONCEALMENT UNDER PATCHED FINISHES SHALL BE INSTALLED IN RIGID CONDUIT, OR EMT. WHERE RACEWAYS ARE INSTALLED FOR OTHERS TO USE, OR FOR FUTURE USE, PROVIDE NYLON PULL STRING. PENETRATIONS THROUGH FIRE RATED CONSTRUCTION SHALL BE SEALED USING 3M FIRE BARRIER CAULK, NELSON ELECTRIC FLAMESEAL OR T &B FLAMESAFE OR OTHER METHOD APPROVED BY THE STARBUCKS CONSTRUCTION MANAGER. SWITCHES AND RECEPTACLES NAMEPLATES CONDUCTORS AND TERMINATIONS PROVIDE PERMANENT NAMEPLATE LABELING ON ALL DISCONNECTS AND PANELS. INCLUDE LOAD SERVED, VOLTAGE, PHASE, HORSEPOWER, FUSE SIZE, AND TYPE. FOR PANELS, INCLUDE DESIGNATION (SUCH AS "PANEL A "). MOUNTING MOUNT DISCONNECTS INDEPENDENTLY OF THE MECHANICAL UNIT HOUSING UNLESS SPECIFICALLY ACCEPTED BY THE LOCAL CODE AUTHORITY. PROVIDE UNISTRUT SUPPORT CHANNELS MOUNTED IN COORDINATION WITH ROOF PENETRATION AND PATCHING WORK. COORDINATE WITH GENERAL CONTRACTOR. GROUNDING ALL MAJOR PARTS NOT CARRYING CURRENT, INCLUDING BUT NOT LIMITED TO, SECONDARY FEEDER CIRCUIT, EQUIPMENT AND PANELBOARD ENCLOSURES, PULL AND JUNCTION BOXES, SHALL BE PROPERLY GROUNDED. METALLIC RACEWAYS SHALL UTILIZE DOUBLE LOCKNUTS AND OTHER FITTINGS TO PROVIDE GROUND CONTINUITY. CONDUCTORS CONDUCTORS SHALL BE COPPER, INSULATED FOR 600V. TYPE THWN /THHN. NUMBER 12 AWG MINIMUM. MOTORS AND OTHER WIRING THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WIRING, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN THOUGH THE MOTORS AND EQUIPMENT, MAY BE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. SHALL BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. THE EQUIPMENT MAY INCLUDE BUT IS NOT LIMITED TO SUCH ITEMS AS MOTORS AND INTERLOCKS, STOREFRONT AND OTHER SIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES, ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATA SYSTEMS, INTERCOMS, SOUND SYSTEMS, AND OTHER APPLIANCES. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT BEFORE INSTALLING THE CONDUIT OR OUTLETS. SWITCHES SLATER OR APPROVED EQUAL WITH MATCHING COVERPLATES UNLESS NOTED OTHERWISE. SEE E3.0. RECEPTACLES SLATER OR APPROVED EQUAL WITH MATCHING COVERPLATES UNLESS NOTED OTHERWISE. SEE E2.0. INSTALL RECEPTACLES WITH GROUND PIN FACING IN A DIRECTION PER THE GENERAL CONTRACTOR. PROVIDE GFCI TYPE TYPE WHERE INDICATED. SHOW WINDOW RECEPTACLES SHALL BE PAINTED TO MATCH ADJACENT SURFACE. OCCUPANCY SENSORS (FOR SITES HAVING RESTROOMS) WATTSTOPPER, UNLESS NOTED OTHERWISE, FOR USE IN ALL TOILET ROOMS. SEE E2.0 AND E3.0. CONDUCTORS AND TERMINATIONS LOW VOLTAGE PANELBOARDS PROVIDE BRANCH CIRCUIT PANELBOARD(S) AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HERON. PANELBOARDS SHALL HAVE PLUG -IN BREAKERS AND MAN LUGS ONLY OR MAIN BREAKERS AS REQUIRED. PANELBOARDS SHALL BE CONSTRUCTED WITH ALUMINUM BUS AND BE ENCLOSED IN NEMA 1 TYPE RECESSED HOUSING AS MANUFACTURED BY "SQUARE D ", "ITE ", OR EQUAL AND CAPABLE OF ACCEPTING GFI BREAKERS. ENCLOSURE(S) SHALL BE COMPLETE WITH A HINGED DOOR, CYLINDER LOCK, AND A NEATLY TYPED DIRECTORY UNDER PLASTIC COVER IN EACH PANEL DOOR. ALL MULTIPLE POLE BREAKERS SHALL HAVE A COMMON TRIP HANDLE. FOR EXISTING PANELS SHOWN TO BE REUSED OR RELOCATED, PROVIDE ANY NEW BREAKERS NECESSARY. ALL LOW VOLTAGE WORK SHALL COMPLY, BE PERMITTED AND INSPECTED PER STATE (AND AHJ) REQUIREMENTS. ALL LOW VOLTAGE WORK SHALL BE INSTALLED BY A LICENSED CONTRACTOR IN ACCORDANCE WITH THE STATE AND AHJ REQUIREMENTS. ALL LOW VOLTAGE CABLING INSTALLED UNDERGROUND SHALL BE ROUTED IN A CONDUIT RACEWAY AND CABLING /CONDUCTORS SHALL BE LISTED FOR USE IN WET LOCATIONS AND FOR LOW VOLTAGE APPLICATION PER AHJ. ALL LOW VOLTAGE CABLING ROUTED INDOORS SHALL BE ROUTED CONCEALED IN WALLS /CEILINGS IN A CONDUIT RACEWAY (UNLESS STARBUCKS CM AND AHJ AUTHORIZE IT TO BE ROUTED EXPOSED THROUGH WALL /CEILING). IF APPROVED BY STARBUCKS CM & AHJ TO BE ROUTED EXPOSED, CABLING SHALL BE PROPERLY FASTENED SUPPORTED PER CODE, AHJ, AND INDUSTRY STANDARDS. CABLING NOT ROUTE IN CONDUIT SHALL BE PLENUM RATED WHERE REQUIRED BY CODE OR AHJ (CONFIRM WHETHER CEILING SPACE IS BEING USED AS AN AIR PLENUM.) ALL LOW VOLTAGE CABLING OUTDOORS SHALL BE ROUTED IN CONDUIT PER CODE AND AHJ REQUIREMENTS. CONDUCTORS CONDUCTORS SHALL BE COPPER, INSULATED FOR 600V. TYPE THWN /THHN. NUMBER 12 AWG MINIMUM. MOTORS AND OTHER WIRING THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL NEEDED CONDUIT, WIRING, AND SAFETY SWITCHES FOR ALL MOTORS, AND EQUIPMENT, EVEN THOUGH THE MOTORS AND EQUIPMENT, MAY BE SUPPLIED BY OTHERS. MOTORS, CONTROLS, ETC. SHALL BE FURNISHED BY THE SUPPLIER OF THE DRIVEN EQIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE ALL WORK AND CONNECTIONS NEEDED TO MAKE THE SYSTEM COMPLETE AND OPERATIONAL. THE EQUIPMENT MAY INCLUDE BUT IS NOT LIMITED TO SUCH ITEMS AS MOTORS AND INTERLOCKS, STOREFRONT AND OTHER SIGNAGE, STARTING DEVICES, MOTOR CONTROLLERS, FLOAT SWITCHES, ALARM DEVICES OR SYSTEMS, PUSH BUTTONS, EXHAUST FANS, DATA SYSTEMS, INTERCOMS, SOUND SYSTEMS, AND OTHER APPLIANCES. THE ELECTRICAL CONTRACTOR SHALL VERIFY EQUIPMENT LOCATION AND SIZES WITH THE TRADE AND VENDOR SUPPLYING THE EQUIPMENT BEFORE INSTALLING THE CONDUIT OR OUTLETS. MAR 042008 -`EMIT CEN1-EF. SEE SCOPE OF WORK ON SHEET E1.0 STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318-1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE 1HE EXCLUSRE PROPERTY OF STARBUOKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THDA) WITHOUT STAREUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COM REV DATE DESCRIPTION 02 -26 -08 LL /CITY COMMENTS 03-03 -08 LANDLORD REVISIONS STARBUCKS COFFEE PROJECT: SOUTHCENTER 11 806 SOUTHCENTER BLVD #1310 PROJECT #: 12197-001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE PANEL SCHEDULES & ELECTRICAL SPECIFICATIONS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER EI.I POWER PLAN FLAG NOTES POWER PLAN GENERAL NOTES POWER PLAN KEY NOTES Q� 7 r ©��l' �� , PROVIDE ALL BRANCH CIRCUITING AND DEVICES, EVEN IF NOT SHOWN. PROVIDE ALL WIRING AND WIRE QUANTITIES TO ACCOMPLISH CIRCUITING TO MEET SPEC REQUIREMENTS AND APPLICABLE CODES. OWNER PROVIDED SPEAKER. MOUNT AT ELEVATIONS PER GENERAL CONTRACTOR. F &I ANY NEEDED CONDUITS AND CONDUCTORS (NOT SHOWN). FLAG NOTE NOT USED. PROVIDE WALL PENETRATIONS AND ELECTRICAL CONNECTIONS AS NEEDED FOR SIGN. 12 FLAG NOTE NOT USED. FLAG NOTE NOT USED. PROVIDE RECEPTACLE FOR WARMING OVEN. COORDINATE WITH OVEN MANUFACTURER FOR NEMA RECEPTACLE TYPE. (F &I #10 CU. CONDUCTORS). 15 CONFIRM VOLTAGE REQUIREMENTS FOR ALL EQUIPMENT. IF NEEDED THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK BOOST TRANSFORMERS TO BE LOCATED IN AN ACCESSIBLE LOCATION ABOVE THE CEILING WITHIN 6' OF THE ELECTRICAL PANEL. IF LOCAL CODES DO NOT ALLOW INSTALLATION ABOVE CEILING, THE TRANSFORMERS SHALL BE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLE TRANSFORMERS INCLUDE ACME. F &I ANY NEEDED ADDITIONAL O.C.P. >4-PLEX FOR PHONE BOARD ABOVE CEILING (CONFIRM LOCATION OF BOARD AND OUTLET). NOT ALL SWITCHES ARE NECESSARILY SHOWN. 18 ON GROUND FLOOR OF STARBUCKS BUILDING. SEE NOTES FOR MOUNTING ELEVATION. 19 SEE LAN /POWER /PHONE /SECURITY SYSTEM DIAGRAM FOR CIRCUITING. 20 PROVIDE GFI RECEPTACLE, SWITCH AND LIGHT NEXT TO HVAC UNIT PER BUILDING CODE REQUIREMENTS. Rd INDEPENDENT SUPPORT IF NEEDED. COORDINATE RECEPTACLES, SWITCHES AND LIGHTING LOCATIONS WITH SERVICE SIDE OF UNITS. A FURNISH AND INSTALL A COMPLETE AND OPERATING SYSTEM. ALL ITEMS O ARE NOT NECESSARILY SHOWN. Q ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. C DIMENSIONS ARE TO FINISH FACE UNLESS OTHERWISE NOTED, D REFER TO DETAIL SHEETS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ELECTRICAL DEVICES. E THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR CONFIRMING ALL Q VOLTAGE REQUIREMENTS ON ALL EQUIPMENT AND PROVIDING BUCK -BOOST NECESSARILY NDICATEp BE NEEDED FOR CODE. ALL ARE NOT O ELECTRICAL CONTRACTOR SHALL COORDINATE WITH PLUMBING AND HVAC CONTRACTORS FOR ANY ADDITIONAL EQUIPMENT NEEDING POWER. aG ALL FUTURE EQUIPMENT NEEDED HEREIN SHALL BE PROVIDED WITH AN APPROPRIATE RECEPTACLE AND FULLY WIRED. EVEN IF NOT SPECIFICALLY INDICATED. 37 Q ROLL -UP GRILLE DOOR: FURNISH AND INSTALL ELECTRICAL CIRCUIT. ROUTE CIRCUIT CONCEALED FROM PANELBOARD TO EACH DOOR. F &I INTERIOR AND EXTERIOR DOOR SWITCHES /KEYS AND CIRCUITS (NOT SHOWN). CONFIRM POWER, CONTROL AND SWTCH REQUIREMENTS. ® FURNISH & INSTALL NEMA 6 -30R RECEPTACLE @ 28" AFF, & ALL NECESSARY CONDUIT, WIRE ( #10) & CONNECTIONS BACK TO SERVING PANEL TO SUPPORT WARMING OVEN. 39 SURE -SHOT DISPENSERS: PROVIDE RECEPTACLE Q 26" AFF. 40 CUP LABELER - FURNISH AND INSTALL BACKBOX FOR DATA OUTLET AT 26" AFF. ROUTE (1) 3/4" CONDUIT FROM BACKBOX TO DATA RACK NEAR MANAGER'S WORK STATION. LABEL CONDUIT FOR DATA CABLING AND PROVIDE PULL STRING FROM END TO END. CONDUIT NOT SHOWN (TYPICAL). 41 PROVIDE ELECTRICAL CONNECTION TO WATER HEATER. CONFIRM ELECTIRICAL REQUIREMENTS PRIOR TO ROUGH IN. 42 LCD MONITOR: PROVIDE RECEPTACLE AND J -BOX FOR VIDEO CABLE. ROUTE 1" CONDUIT FROM LCD J -BOX TO J -BOX ADJACENT TO NOW PLAYING SERVER AND PROVIDE END TO END PULL STRING. 43 NOW PLAYING SERVER: PROVIDE RECEPTACLE AND J -BOX FOR VIDEO CABLE. INTERCEPT CONDUIT FROM LCD MONITOR LOCATION. NUMBER NOT USED. a RETAIL GRINDER: PROVIDE RECEPTACLE @ 26" AFF. Q TWIN BREWER: NEMA 14 -50R RECEPTACLE 26" AFF, 3/4 "C -3 6 AND 1 1D GROUND, CONTRACTOR TO PROVIDE A NEMA 14 -50P CORD CA FOR T BREWER, BRYANT OR EQUAL. a4 FOR ESPRESSO MACHINE, FURNISH AND INSTALL NEMA 6 -50R RECEPTACLE HUBBELL HBL9367 SERIES OR EQUAL AT 30" AFF. ROUTE 3/4" CONDUIT - (2) #6 AND (1) 10 GROUND FROM MACHINE BACK TO PANEL. FURNISH AND INSTALL NEMA 6 -50P ANGLED PLUG, HUBBELL HBL9368 SERIES OR EQUAL. 5 UNDER COUNTER REFRIGERATOR: PROVIDE RECEPTACLE @ 26" AFF. 6 REFRIGERATOR AND /OR FREEZER: RECEPTACLE AT 84" AFF. O ICE MACHINE (AIR COOLED): PROVIDE NEMA RECEPTACLE. 120V 15A HARD WIRE EQUIPMENT CONNECTION. PROVIDE SEPARATE (1) 120V 15A AND (1) 220V 20A DEDICATED CIRCUITS. 09 DISHWASHER (HIGH TEMP): NEMA 14 -50R RECEPTACLE @ 18" AFF, 3/4 "C - 3#6 AND 1 #1O GROUND. 10 RECEPTACLE @ 18" AFF. Rd TELEPHONE JACKS AND WIRING AT EACH LOCATION IF WIRELESS ACCESS IS NOT AVAILABLE. 11 NUMBER NOT USED. ® COFFEE WARMERS AND /OR SCALE: PROVIDE RECEPTACLE @ 26" AFF. 13 BLENDERS: PROVIDE A DUPLEX RECEPTACLE BOX AT 26" AFF ON A DEDICATED CIRCUIT FOR EACH BLENDER. MOUNT BOXES TO DIE -WALL BENEATH BLENDER CABINET. 14 ALL BACK BAR AND FRONT BAR J -BOXES AND OUTLETS SHALL BE SURFACE MOUNTED. PROVIDE CONDUITS AS NEEDED AND (1) ADDITIONAL SPARE CONDUIT BETWEEN ALL J -BOXES FOR FUTURE ELECTRICAL REQUIREMENTS. ALL J -BOXES SHALL BE POSITIONED TO AVOID OBSTRUCTION OF ANY EQUIPMENT SUCH AS REFRIGERATORS AND DISHWASHERS. CONFIRM ALL THE ABOVE WITH GENERAL. lip LOCATION OF SWITCHING. 0 PROVIDE ADDITIONAL OUTLET AND J -BOX ABOVE AS NEEDED FOR SECURITY SYSTEM ABOVE CEILING. 17 FOR SIGNAGE, FURNISH AND INSTALL ELECTRICAL CIRCUIT. ROUTE CIRCUIT CONCEALED FROM PANELBOARD TO SIGNAGE. 18 SAFE: FURNISH AND INSTALL DUPLEX RECEPTACLE AND SECURITY J -BOX AT 1$" AFF. 0 HOT TAP: PROVIDE RECEPTACLE AT 26" AFF. 0 CIRCUIT VOLTAGE SHALL BE AT VOLTAGE RECOMMENDED BY EQUIPMENT MANUFACTURERS. IF NEEDED, THE CONTRACTOR SHALL PROVIDE AND INSTALL BUCK -BOOST TRANSFORMERS TO BE LOCATED IN ACCESSIBLE LOCALIOCODES ABOVE NOT ALLOIW INSTALLATION SITALLATION ABOVE ELECTRICAL R EI�LINGSNE HE IF TRANSFORMERS SHALL BE MOUNTED TO THE WALL JUST BELOW THE CEILING. ACCEPTABLE TRANSFORMERS INCLUDE ACME. FURNISH AND INSTALL ANY ADDITIONAL O.C.P. NEEDED. 21 NUMBER NOT USED. @ MANAGER'S DESK: PROVIDE LAN / POS / ELECTRICAL DEVICES. SEE DETAILS FOR LOCATIONS AND EQUIPMENT. ALL REQUIRED OUTLETS ARE NOT NECESSARILY SHOWN. 23 POS: FURNISH AND INSTALL DUPLEX ISOLATED - GROUNDING TYPE RECEPTACLE AT 18" AFF., INCLUDING GREEN GROUNDING WIRE AND ISOLATED GROUNDING WIRE BACK TO SERVING POWER PANEL PER CODE. FURNISH AND INSTALL (1) J -BOX FOR DATA OUTLET AND (1) J -BOX FOR PHONE OUTLET AT 18" AFF. NUMBER 0 � NOT T USED. 0 4" SQUARE J -BOX MOUNTED ON 1/2" EMT CONDUIT @ LOCATION SHOWN IN SEATING AREA FOR SECURITY SYSTEM STROBE LIGHT. MOUNT TO CEILING OR AT MAXIMUM HEIGHT IF EXPOSED STRUCTURE (NEVER ABOVE BAR UNO). ROUTE CONDUIT TO SECURITY ALARM PANEL LOCATION. " 26 ALARM KEYPAD AND EMERGENCY CALL PHONE: MOUNT @ 54" AFF. ROUTE CONDUIT IN WALL FROM J -BOX AND STUB UP ABOVE CEILING. NUMBER NOT USED. Kio PHONE PANEL ABOVE CEILING. 0 RECEPTACLE FOR FUTURE USE. MOUNT BOX IN A HORIZONTAL ORIENTATION + 96° AFF. DUPLEX CONVENIENCE RECEPTACLE @ 48 AFF. 48" STUB UP POWER, DATA, PHONE AND SECURITY CONDUITS 6" AFF IN THIS LOCATION AS INDICATED ELSEWHERE. ROUTE ABOVE FLOOR POWER CONDUCTORS IN FLEXIBLE METAL CONDUIT WITH GROUND TIGHT TO WALL FROM RECEPTACLES TO NEAREST RIGID STUB -UP AND BACK TO SERVING POWER PANEL. ROUTE DATA, PHONE AND SECURITY CONDUITS UNDERFLOOR BACK TO DATA RACK NEAR MANAGERS WORKSTATION. LABEL DATA AND PHONE CONDUITS "FOR DATA CABLING ", PROVIDE INSULATED BUSHINGS, AND PROVIDE PULL STRING FROM END TO END. LABEL SECURITY "CONDUIT FOR SECURITY" AND PROVIDE PULL STRING FROM END TO END. e MUSIC SPEAKER: SEE ARCH. SHEETS FOR INSTALLATION LOCATIONS. 0 NUMBER NOT USED. B ELER: 0 CUP LABELER: PROVIDE ISOLATED GROUND RECEPTACLE AND BACKBOX FOR LAN CONNECTION @ 26" AFF. 35 FURNISH AND INSTALL WEATHERPROOF, GFI, DUPLEX NEMA 5 -20R RECEPTACLE ON ROOF ADJACENT TO UNIT. MOUNT RECEPTACLE ON FREE - STANDING C- CHANNEL FRAME 18" ABOVE FINISH ROOF LEVEL. 36 TIMECLOCK SHALL BE LOCATED ADJACENT TO THE POWER PANELS. FURNISH AND INSTALL ALL CONDUIT, WIRE, CONNECTIONS, CONTACTORS, ENCLOSURES, TIMECLOCK MODULES AND MISCELLANEOUS NECESSARY TO ENSURE A FUNCTIONAL TIMECLOCK SYSTEM. RECEIVED SMOKE DETECTOR IN DUCT WORK. (SEE DETAIL) CONFIRM REQUIREMENTS. RUN ALL CONDUITS CONCEALED. FLAG NOTE NOT USED. RUN CONDUITS CONCEALED IN SOFFIT, WALL, CEILING OR BELOW SLAB IF APPLICABLE. IF ANY CORD AND PLUG IS OBSTRUCTED BY CABINET PARTITIONS, PROVIDE ADDITIONAL OUTLET. STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1676 10 SEE ARCH. SHEETS FOR EXACT LOCATIONS OF SIGNS. � VERIFY ACTUAL RATINGS, OF CIRCUITS, BREAKERS AND CONNECTIONS IN FIELD. THESE PLANS AND SPECIFICATIONS, AS WEI AS STARBUCKS' NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS DI N. CORPORATION. O5URE AND/OR NREPRODUCTION, THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. (425) 739 -6051 SUITE 200 (425) 739 -7362 KIRKLAND, WA 98033 AER123 @AQL.CQM NOTES: 1. CEILING SPACE IS BEING USED AS A RETURN AIR PLENUM. F &I WIRING PER CODE AND LANDLORD REQUIREMENTS. 2. F &I WIRING & MISCELLANEOUS FOR HVAC CONTROL SYSTEM NOT SHOWN. COORDINATE WITH GENERAL. T T 7 28 (FORMERS ABOVE CEILING - SEE 200A 480V 30 FUSED DISCONNECT REQUIREMENTS. SWITCH BY LANDLORD (CONFIRM). TO HAVE CEILING AREA IF NEEDED. LANDLORD FURNISH & INSTALLED 480V FEEDER FROM MAIN ELECTRICAL ROOM a- REV DATE JC DESCRIPTION / ' \ 02.26 -08 LL /CITY COMMENTS NOT ALL CONDUITS /CIRCUITS CALLED FOR IN NOTES ARE SHOWN IN PLAN VIEW. A 03 -03 -08 LANDLORD REVISIONS 45KVA WALL MOUNTED PANELS BUT BELOW STRUCTURAL DETAIL S1 FIR COORDINATE WITH GENERAL RAISED IN THIS G a oAk O. L� NOTE: WIRE QUANTITIES ARE NOT SHOWN. FURNISH & INSTALL PER CODE WITH DEDICATED NEUTRALS FOR ALL GFI BREAKER PROTECTED CIRCUITS (TO PREVENT FALSE TRIPS). IN ADDITION, FURNISH AND OTHERWISE. SE. CONDUITS. ALL ISSN NEW UNLESS SS NOTED IN ALL PVC Y� E A -32 VIA TIMECLOCK P Q �' € �j ��__ —� 20$V RECESSED ELECTRICAL PANEL 480V RECESSED ELECTRICAL PANEL 'H' 8V RECESSED 20 ELECTRICAL PANEL TIMECLOCK 36 SWITCHBANK LOCATION 3210 '1111�i `1ti 0 20 �' __ `� .�"��;i � I fa iii �I G o 411 �I:� : i�!� ��) III► . o [ 1 I I r ,- 26 r ' �M- w l I �`�y ii-ir- D � r�� I - - �"-"` _ x ' :- 7,9,11,13 L_ ■ -1 A-- 20'22'2 8-12, 4 / x'28 '' TO SECURITY PANEL B A C K B A R 14 �� -y A--31 ep - PliAllEll / I TYPICAL - A -15,1 k :2,4,6 A ,19 30 i �► 1� �_ 7 ► ' _ _33 �■Ir A- 14,16,18 , 4 A) ■ A -27 °3 �� P _ AWN 27- r� -1,3 A_5,7 ,- `" �..�I �• T -�--' r�� • 4111) 1-- - 1101..10),,,,„. © ��s_� 27 H-- 10,12,14 (ON ROOF) i� r WORKROOM r ,� p 3 5 0 VAV UNIT ABOVE CEILING CONFIRM POWER REQUIREMENTS AND F &I DISCONNECT SWITCH IF NEEDED). inc FOR PHONE SYSTEM - EXTEND CONDUIT THRU ADJACENT TENANT'S SPACE (TIGHT TO TTRAYCIS LOCATED WITH CORRIDOR (CONFI M). ,..., J N : r, g ,, ���1 • �Q / 00 0 >>>>> (TYPICAL) 2 _�B 'p -21 r 8 '' TO SECURITY PANEL 'r� �'y•= =ti ` 1 tea► ► I • �© 0 ' - =2 : -20 �� ®�G� e� ,�+A R�� ®N, ��G CO �pp7® N Q�� �pR 2 1 COI 1. :-19 SALES B -23, r�� . "; �I�A �I -4,6,8 ��� Q �% *OW 0 III �i �o�~ J:;�7 ©r' � - _ TO h MONITOR �_'� ��,� ` /E� 20 TO SERVER H_6�8 f, e; ��► �....._ um A -911 3 /� — — SEATING 0 - A "' B -17 1 �-- 1 �4'!r� ' (ABOVE CEILING) �` ®�' . ® PROJECT #: 12197 -001 ISSUE DATE: 01/28/08 CHECKED: JOHN BEEBE DESIGNED: CHRIS RENSCH DRAWN: SHARON HARRIS p •L A -29 3811 , — © i!I A ADL7 11 (CONFIRM IF POWER IS REQUIRED) P,r J r j )1 ', r' ' % ! ;' SHEET TITLE ELECTRICAL POWER PLAN SCALE: (DO NOT SCALE DRAWINGS) ELECTRICAL CONTRACTOR TO COORDINATE PLAN WITH PM FOR COLOR OF OUTLETS, SWITCHES AND FACE PLATES IN MAR 04 2008.: PERMIT CENT E� �� =. - ' cow 4 �. .. - : _ . . dl �'(:. `e /. �I `'¢ 1 `' '� . , .`t',. ;` F ,p 1.9023 . , 115- o��. SEE SCOPE OF WORK 0 1 2 3 4 8 12 CUSTOMER AREA AND IN RESTROOM. ON SHEET E1.0 i.:... SHEET NUMBER E2.0 EXPIRES _ -..D _7,. - BLENDER 1 -TWIN BREWER 1- REFER(2 EA) /LABELER/ FRAPP /WARMERS 2- WARMING OVEN �1-REFER/LABELER T 2 -40A ESPRESSOS 1- REFERS(2 EA) /HOT TAP 1 -SPARE POWER Wwwweld r- w `I`` 1 BACKBAR 1- z SCAL; MSC EE PO1hER 0000000 (TYPICAL AT ALL CONDUIT STUB -UP LOCATIONS) -E, I 200A FUSED DISCONNECT SWITCH r T LAiN1 (, IFA CUP 1 ,`v\\ 1 I I 1 1 -SC �\ 1--LA SPARE - 1 -LAN SAFE 1-LAN P05/ 1 -LAN SPA SLAB ON GRADE - EXISTING GRADE BEAMS AND PILE CAPS BELOW SLAB (NOT ALL SHOWN). DO NOT PENETRATE CUT THESE EXISTING STRUCTURAL ELEMENTS. (CONFIRM REQUIREMENTS FOR CUTTING, BACKFILL AND PATCHING SLAB WITH LANDLORD'S ENGINEER). ROUTE ALL CONDUITS UNDER OR AROUND THESE ITEMS. /POS PHONE SALES POWER PANELS® 1- GRINDER 1-FOODCASE ELECTRICAL UNDERSLAB CONDUIT PLAN 0 1 2 3 4 12 IT RACK MANAGER'S DESK GENERAL NOTES: 01 CONTRACTOR IS TO FURNISH AND INSTALL PULLSTRINGS THROUGH ALL CONDUITS. STUB CONDUITS UP IN LOCATIONS PER ARCHITECTURAL SHEETS. QUANTITIES OF CONDUITS PER THIS SHEET, NOT ARCHITECTURAL. ALL UNDERSLAB (POWER & LAN) CONDUITS SHALL BE 3/4" PVC. U.O.N. ALL STUB UPS & ELBOWS FOR POWER, LAN & OTHER SHALL BE RIGID STEEL. a SEE PLUMBING PLANS FOR ADDITIONAL UNDER FLOOR ITEMS (TYPICAL). 0 CONTRACTOR SHALL F &I CORE DRILLS, CONCRETE CUTTING, AND PATCHING TO STUB-UP RACEWAY THROUGH FLOOR SLAB. COORDINATE WITH STARBUCKS AND GENERAL CONTRACTOR TO DETERMINE SPECIFIC METHODS AND EXACT LOCATIONS. Q PROTECT CONDUIT OPENINGS FROM CONTAMINANTS AFTER CONDUITS ARE INSTALLED AND PRIOR TO BACKFILL.. Q IF POSSIBLE, ALL STUB UPS SHALL BE 4" OC MINIMUM. @:: CONDUITS ROUTING TO POWER PANELS SHALL EXTEND UP WALL UNDER PANELS AND TERMINATE IN PANELS WITH APPROPRIATE FITTINGS AND BUSHINGS READY FOR WIRE TO BE PULLED BY OTHERS. F &I J- BOXES /WIREWAYS TO ACCOMPLISH THIS IF NECESSARY. 4�J LABEL ALL CONDUITS SO VENDORS WILL KNOW WHICH CONDUITS TO USE, SUCH AS 1-0 DT SIGNAGE" OR TO SOUTH SIDE OF DT WINDOW FOR POS EQUIP ". CONDUCTORS ARE NOT SHOWN (TYPICAL). REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAR 2 'T 2008 City Of Tukwila BUILDIN DIVISI s N NOTE: 1. ALL BELOW GRADE CONDUITS SHALL BE SUPPORTED FROM SLAB WITH STAINLESS STEEL HANGERS PER CODE AND LANDLORD REQUIREMENTS. REC RMT MAR 0 4 2008 PERMIT GENT STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS WELL AS STARBUCKS' NAME AND LOGO. TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRRTEJ CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 1155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COM REV DATE JC DESCRIPTION STARBUCKS COFFEE PROJECT: SOUTHCENTER 11 806 SOUTHCENTER BLVD #1310 PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL UNDERSLAB PLAN SCALE: (DO NOT SCALE DRAWINGS) 1E)17E-S. /d! 1 SHEET NUMBER E2.1 F SWITCHBAN K LOCATION 200A FUSED DISCONNECT SWITCH SEE NOTE NOTE 4 LIGHTING PLAN SCHEDULE ITEM* QTY DESCRIPTION MANUFACTURER MODEL * VOLTS WATTS AMPS VD REMARKS SKU + SHIP PENDANTS /SCONCES L037 4 PENDANT WHITE WHITE - DIMODA RESOLUTE WHITE HAND BLOWN 120 IOIOIIIIPIIPIIPIIIIIIIIIIIIIIII aT ..- 119703 VD W/ L949 LAMP 1060444 1 I LLL 3PL TRACK 8c TRACK FIXTURES L145 11 TRACK FIXTURE WHITE JUNO R552WH 120 IOIOIIIIPIIPIIPIIIIIIIIIIIIIIII aT ..- 119703 VD USES L956 LAMP 165938 VD L174 1 TRACK WHITE 8' JUNO RBWH 120 18 � LITHONIA W/ (3) L986 LAMPS 165939 VD L175 1 TRACK WHITE 4 JUNO R4WH 120 18 SAME AS L500 EXCEPT WITH EMERGENCY BATTERY PACK USES FRAME L500 AND LAMP L949 120167 VD ELLIQLESCENT FIXTURES L500 r � 0 10 DOWNLIGHT FRAME - 6 "DIA FLUOR LITHONIA LP6F 18DTT /TRT MVOLT 120 IOIOIIIIPIIPIIPIIIIIIIIIIIIIIII aT ..- 119703 VD USES L949 LAMP 192404 VD L563 3 2X4 FOR ACT LITHONIA 2GT 332 Al2 120GEB 120 18 � LITHONIA W/ (3) L986 LAMPS 119695 VD L961 11 RECESSED DOWN 6 "DIA LITHONIA 607A 120 18 SAME AS L500 EXCEPT WITH EMERGENCY BATTERY PACK USES FRAME L500 AND LAMP L949 192405 VD ANCILLARY FIXTURES L851 ,,...__ _..._. 1 _,._ :....., .� - __ LITHONIA . _...r.....r..�. .� V11 �T .. 55 ..� 120 IOIOIIIIPIIPIIPIIIIIIIIIIIIIIII aT ..- 119703 VD L853 381903 EMERGENCY /EXIT LIGHT- WHITE LITHONIA LHQMSW3G ELN - HITE .�� nIIUIIIIIIII � W/ GREEN ILLUMINATED LETTERING SYLVANIA VD L859 18 � LITHONIA - HBMACK ELN .■041111PIWINIMAIIII"M"--W-/- GR-EEN 120 ILLUMINATED LETTERING VD VD LOCALLY SOURCED L530 1 HAND OFF PENDANT CLUSTER IVORY RESOLUTE IVORY CLUSTER 120 75 CLUSTER OF 3 -L900 LAMPS 381903 3PL LAMPS /BULBS L900 3 LAMP FOR HAND OFF PEND - 75W SYLVANIA DIRECTOR COATED 120 75 SHATTER -PROOF VD L949 5 DULUX 18W COMPACT FLUOR SYLVANIA CF18DDE827 120 18 W /(2) L986 LAMPS AND 600 LUMEN BATTERY TO POWER 2 LAMPS VD VD L955 10 DULUX 18W COMP FLUOR COATED SHAT -R- SHIELD CF18DDE827 COATED 120 18 SAME AS L500 EXCEPT WITH EMERGENCY BATTERY PACK SHATTER RESISTANT REPLACEMENT FOR L949 192402 VD L956 11 60 PAR 30 LAMP COATED SHAT -R- SHIELD 60 PAR 30 /CAP /SPL /NFL25 130 60 LIGHTS IN FOOD PREP AREAS VD L986 15 48 IN LAMP FOR 2X4 OR STRIP SYLVANIA F032/830ECO 120 32 119712 VD ADDITIONAL ITEMS v AILS 2 FLDURESCENT LAMPS -STRIP LITHONIA C232- 120 -GEB W/ (2) L986 LAMPS GC ELC 1 EMERGENCY BACKUP FLUOR. STRIP LITHONIA C232 - 120 -EL6 120 W /(2) L986 LAMPS AND 600 LUMEN BATTERY TO POWER 2 LAMPS VD ELD 1 EMERGENCY BACKUP DOWNLIGHT LITHONIA LP6F -18DTT /TRT /EL -MVOLT 120 SAME AS L500 EXCEPT WITH EMERGENCY BATTERY PACK VD LIGHTING SCHEDULE NOT S: 1, CONTRACTOR SHALL COORDINATE WITH SCHEDULE AND STARBUCKS TO ENSURE THAT ALL LIGHT FIXTURES IN FOOD PREP AREA ARE PROVIDED WITH SHATTER PROOF LAMPS OR LENSES 2. F &I PENDANTS AS MAY BE NEEDED. 3. CONFIRM LOCATION WITH STARSUCKS. 4. CONTRACTOR SHALL CONFIRM REQUIRED LETTER COLOR WITH AHJ. POWER PANELS NOTE: CONDUCTOR QUANTITIES ARE NOT SHOWN. F &I PER CODE WITH SWITCHING AS INDICATED BY LETTER DESIGNATION, NOTE, OR LOCAL SWITCH. LIGHTING PLAN GENERAL NOTES LIGHTING PLAN KEY NOTES CA PROVIDE A COMPLETE AND OPERATING SYSTEM. ALL ITEMS ARE NOT NECESSARILY SHOWN. 1 a COORDINATE WITH GC AS TO WHOM IS TO PROVIDE ALL LIGHT FIXTURES AND LAMPS UNLESS NOTED OTHERWISE. Q ELECTRICAL CONTRACTOR RESPONSIBLE FOR SITE INVESTIGATION PRIOR TO START OF WORK TO REVEAL FULL SCOPE OF WORK. Q REFER TO ARCHITECTURAL CASEWORK DETAILS FOR EXACT LOCATIONS OF LIGHT FIXUTRES LOCATED IN CASEWORK. Q REFER TO ARCHITECTURAL PLANS FOR EXACT FIXTURE LOCATIONS. CF CONFIRM ALL QUANTITIES IN SCHEDULE WITH THOSE IN PLAN VIEW. COMMISSIONING REQUIREMENTS THE CONTRACTOR SHALL FURNISH AND INSTALL LIGHTING CONTROLS THAT INCLUDE DAYLIGHT CONTROLS, AUTOMATIC SHUT -OFF CONTROLS, AND AUTOMATIC TIME SWITCHES WHERE INDICATED. TEST TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THEY OPERATE IN ACCORDANCE WITH THESE PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER AND STARBUCKS, O TIMING DEVICE FOR SIGNAGE TO BE LOCATED ADJACENT TO POWER PANELS. COORDINATE WITH STARBUCKS AND LANDLORD FOR TIME ON /OFF AND PUT ON A 24HR /DAY LOCK ON CIRCUIT. THE TIMING DEVICE SHALL BE TORK SERIES Z, #Z7200. • INTERIOR LOGOS, AND LIGHTS IDE 1 BE ON 24 HOUR PER DAY LOCK -ON CIRCUIT. C NOT ALL SWITCHES ARE NECESSARILY SHOWN. Q ADJUST FOCUS OF ALL TRACK AND RECESSED DIRECTIONAL LIGHTING TO FULLY ILLUMINATE ALL ARTWORK, MENU BOARDS, AND MERCH BAYS. C5 RUN ALL CONDUITS CONCEALED (TYPICAL). CONTRACTOR TO COORDINATE WITH PM FOR COLOR OF OUTLETS, SWITCHES AND FACE PLATES IN CUSTOMER AREA AND IN RESTROOM. TO TYP (MOUNT ABOVE TRANSLUCENT CEILING PANELS - CONFIRM) LIGHTING PLAN ECE •VED MAR 042008 PERM) T CEMTEF STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIIE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUC1ON, MQDFMATION, DISCLOSURE AND /OR USE OF 1NESE MATERIALS (OR ANY POR110N OF 11150 WITHOUT STARBUCKS' PRIOR %KITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23@AOL.cOM REV DATE DESCRIPTION ' 02 -26 -08 LL /CITY COMMENTS STARBUCKS COFFEE 0 r alct 0 LLI w Z z LLI 0 I I- 0 0 0 (0 Go w 0 co co c Q � 0 PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE LIGHTING PLAN 8( SCHEDULE SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E3.0 SLATING SEATING 0 SEATING WORKROOM EMERGENCY LIGHTING PLAN- PHOTOMETRICS MAR 2 7 2003 City Of Tukwila B YLDIN . D . I ENTIRE SHEET IS NEW. CEWED MAR 042008 PERMIT CENTEA STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS, AS % U. AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE IXCLUZE PROPERTY CF STARDUCKS CORPORATION. ANY REPROCUCTION, MODIFICATION, DISCLOSURE AND /OR USE OF THESE MATERIALS (OR ANY PORTION OF THEW) NITHOUT STARBUCKS' PRIOR INiIT1EN CONSENT I5 STRIC1LY PRCNIBITED. CONSULTANTS ENGINEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COMI REV DATE DESCRIPTION 02 -26 -08 LL /CITY COMMENTS STARBUCKS COFFEE CD c) 0 riszweN MAiLMEZO co LU ui co F- co 0 <F- 15 0 co CO c0 i E— v z 0 a. PROJECT #: 12197 -001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 02/26/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE EMERGENCY LIGHTING PLAN - PHOTOMETRICS SEE SCOPE OF WORK ON SHEET E1.0 SHEET NUMBER EXPIRE 'HOTSPOT' TELEPHONE LINES -2 CAT5 CABLES J -BOX FOR T1 INTERNET CONNECTIONS- DEDICATED 1" EMT CONDUIT TO SECURITY (BY OTHERS). -� MOUNT 92" AFF. PROVIDE AN ORANGE COVER PLATE. PANEL J -BOX. Ti 'HOTSPOT' LINE -1 CAT5 CABLE J -BOX FOR TELECOMMUNICATION WIRING -MOUNT (BY OTHERS) ABOVE CEILING, ROUTE BACK TO DEMARC PANEL. DEDICATED 3/4" EMT CONDUIT TO SECURITY PANEL J -BOX. (2) 1" EMT CONDUITS FOR SECURITY AND VIDEO I PLENUM CABLES. DSL /FRAME RELAY LINE -1 CAT5 _— SECURITY STROBE J -BOX CABLE (BY OTHERS) n _ SECURITY PANEL J -BOX -MOUNT @ 92" AFF & 15" OVER FROM ADJACENT DUPLEX. J- BOX WITH COVERPLATE FOR NOW PLAYING SERVER * 11 II II �� II II _ o - - 0-- go _ L - - - AL DEDICATED 1/2" EMT CONDUIT TO SECURITY PANEL J -BOX WHERE APPLICABLE LINE OF CEILING / STROBE LOCATION J -BOX DEDICATED POWER CIRCUIT TO PANEL '� i °v ELI! o D (IF PRESENT) // ��^ P I SAFE ARE _ o 1- EACH CAMERA I MOTION DETECTOR DEDICATED POWER CIRCUIT TO PANEL RECEPTACLE FOR NOW PLAYING SERVER 3/4" EMT CONDUIT (3y OTHERS) �► (BY OTHERS) = - J -BOX FOR DSL /FRAME RELAY LINE -MOUNT 92" AFF. MICROPHONE /SPEAKER FRONT DOOR CAMERA J -BOX (BY OTHERS) II II I I H 11 DUPLEX FOR SECURITY PANEL -MOUNT 92" AFF. SECURITY J -BOX J BOX FOR POS TELEPHONE. POWER CIRCUIT TO PANEL c - - QUADPLEX FOR SECURITY CAMERA POWER SUPPLIES -MOUNT 92" AFF. , II I II / RECEPTACLE - 4- SQUARE BOX FOR LAN. RECEPTACLE DEDICATED DUPLEX FOR POS. II FOR GRINDER � = = DUPLEX FOR SECURITY -MOUNT @ 48 AFF. 48" r .� 1 FOR SCALE RECEPTACLES FOR _ 1 DUPLEX OUTLET FOR no.isl a MUSIC SYSTEM or��� ■� I I , J FOR POS STATION EXPEDITOR STATION POS STATION SCALES, CHECK VALIDATION &CASH POs STATION -BOX SECURITY KEYPAD. WORKSTATION PLUG I 1 1 1 — DEDICATED DUPLEX (ORANGE) _ _ I �RAW�R� N--- ----- - -1 11 a I III / 1 _ =-= _ _ - - - 1W 11 1 1 II II IN ONLY ISOBAR HERE-MOUNT @ 42" AFF. _ - ^ 7 1 I ( Q SEA OTHER DETAILS 1 I I I 0 FOR P0DITIONAL REC'. 11 11 \- HI 1 1' I I I , J BOX FOR POS TELEPHONE. 4 SQUARE BOX FOR LAN. DEDICATED DUPLEX FOR POS. EiL III — — I H- v o I, I II •r' o 1 °o °o I 1 : o °°SAFE 1 -" I I L 1 1 11 L— - --J T - i RECEPTACLES FOR SCALES, CHECK VALIDATION & CASH DRAWERS 1 WINDOW P05 BEAN POS MAIN POS WITH SAFE DEDICATED CONDUIT TO SECURITY PANEL J -BOXY J- BOX LOCATED ADJACENT TO SAFE DEDICATED DUPLEX OUTLET FOR SAFE SQUARE BOX FOR QUAD RECEPTACLE MANAGER'S STATION 12" AFF. — J -BOX FOR (2) TELEPHONE JACKS. NOTES 1) COORDINATE ALL J -BOX LOCATIONS WITH SECURITY VENDOR PRIOR TO ROUGH IN INCLUDING SECURITY PANEL, SAFE, KEYPAD, STROBE, FRONT DOOR CAMERA, MOTION DETECTOR, MICROPHONE /SPEAKER, AND CAMERA. 2) COORDINATE "SECURITY J -BOX" AND "SECURITY STROBE J- BOX" LOCATIONS WITH SECURITY VENDOR PRIOR TO ROUGH-IN. 3) CONDUCTORS ARE NOT SHOWN. . • POWER CIRCUIT(S) TO PANEL (ORANGE) SEE E2.O LAN/POWERIPHONE/SECURITY SYSTEM DIAGRAM MAIN BONDING JUMPER SERVICE DISCONNECT SWITCH 1200A PANEL - '1E' SWBD 4S1 E1 F (CONFIRM) (OTHER TENANT SWITCHES OUTSIDE OF STARUCKS SPACE PANEL -- -NOT ��iDE COMP P� 7Q -CEO ,1 �i �f TuiCUVjjB r�® N ®I!/ISION AVAILABLE FAULT CURRENT = 16,874AMPSAIVCE TO NEUTRAL BUS GROUND BUS BOND TO BLDG. STEEL PER CODE. BUILDING STEEL COPPER GROUNDING ELECTRODE Ill li OR PANEL BOARD BOND TO METAL WATER PIPE. FED FROM PER SHELL ELECTRICAL PLANS 480/277V, 30,4w SHOWN) ( POWER CHECK METER (CONFIRM)BREAKER N N `/ .... EQUIPMENT FOOTING ro - MAIN WATER SHUT -OFF VALVE '_ " 5 0 MAX WATER R SERVICE RVICE _ _ r © -1 a b c A-32 rl I " 4 250KCMIL, W GND AL. MC CABLE (CONFIRM) L ) A -36 n. - PANEL ---� B CKT: 1 3 3 CONTROL ZONE SCHEDULE NOTES AHJ) GROUND ROD(S) -- (IF ALLOWED BY NOTES: W = /f V:Z , MAIN 200A FUSED ( 1 F&I ADDITIONAL RELAYS AS NEEDED. L-. SIGNAGE CONTROL A I 1 ASTRONOMIC TIMESWITCH, TORK *72002, SET TO TURN ON AND OFF WITH MALL LIGHTING SCHEDULE (PER STARBUCKS DIRECTION) ON 24 HRS /DAY LOCK ON CIRCUIT LIGHTING DETAIL IN STARBUCKS 4480KVVA TRANSFORMER 8 208V/120V SPACE NEMA TP -1 GND PER 4 #1 CU., W/ CND. IN 1 -1/2 125A/3P MAIN 3� 4W SWITCH < AVAILABLE FAULT CURRENT 611,541AMPS \ X �45KVA TRANSFORMER UNDERGROUND. CONNECT TO REBAR AT A CLEANED POINT WITH EXOTHERMIC WELD. REBAR SHALL BE A MIN, Y" DIA. AND 20 FT. IN LENGTH, ENCLOSED BY MIN. OF 2" OF CONCRETE. / i 480 - 20$V/12DV 30, 4W NEMA TP -1 GND PER CODE 4 #1 CU., W/ GND. IN 1- "C CODE a - b - c - DISPLAY/ ACCENT WORKROOM FRONTBAR LIGHTING CONTROL INDICATES SWITCH DIAGRAM 4 #250KCM C 3/ CU., AL., W /GND -1/2 W /GND IN `` 3/4"C - AL. IN 2 -1/2"C 25A /3P MAIN 1. THIS DETAIL IS APPLICABLE WHEN STARBUCKS IS MODIFING AN EXISTING OR INSTALLING A NEW BUILDING SERVICE. IF MAIN BUILDING POWER SERVICE IS BY OTHERS, CONTRACTOR SHALL ENSURE GROUNDING SYSTEM INSTALLED BY OTHERS IS PER CODE. 2. GROUNDING ELECTRODE SYSTEM INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH LOCAL CODES AND /OR AUTHORITIES HAVING JURISDICTION. 3. ALL GROUNDING ELECTRODE CONDUCTORS AND BONDING JUMPERS TO BE SIZED PER CODE. D DETAIL GROUN ING i\N..l 125 PANEL 208V/30 60A /3P AMP "B" 200 AM 125 AMP A" B' �� PANEL A PANEL H" 2O8V/30 460V/0 SERVICE ONE —LINE DIAGRAM sio SEE LANDLORD'S SCOPE OF WORK ON SHEET E1.0 0 FILL ANNULAR SPACE W /UL LISTS' (TESTED PER ASTM E 119) FIRESTOP CAULKING WITH A RATING MATCHING THE WALL OR CEILING /FLOOR RATING (SEE ARCH. SHEETS FOR WALL/ CEILING /FL00" RATING). CONDUIT RIGID STEEL SLEEVE INSIDE DIAMETER THAN PASSING THRU. 1" GREATER CONDUIT CONDUCTORS NOTES: li / 31 0 AS NEEDED. PROVIDE DETECTOR, HOUSING, TYPE, REMOTE STATION, V 5120 AND ALL ACCESSORIES. DETECTOR SHALL BE INSTALLED PROVIDE CONTROL UNDER DIVISION 15. CONNECT DETECTOR AS SHOWN. WIRING FOR FAN WHEN STARBUCKS SPACE IS MONITORED BY CENTRAL BUILDING SHUT DOWN FIRE ALARM SYSTEM, GC TO COORDINATE WITH LANDLORD'S ' 0 vs, a IiLT ` HVAC DUCTWORK "C, *14 ALARM CONTRACTOR TO CONNECT BUILDING ALARM SYSTEM NI SAMPLING TUBE SIZED FOR DUCT —Y2 4 TO DUCT DETECTOR AUXILIARY CONTACTS. MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL DUCT SEE SCOPE OF WORK ON SHEET E1.0 l;I IN DETECTOR WITH MINIMUM TWO SETS OF AUXILIARY CONTACTS ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL CONTROL *14 WIRING FROM DUCT DETECTOR TO AC UNIT �� k "`�"`I 1"`��`�` �1 , CONDUIT WALL 6 RATED WALL OR CEILING /FLOOR - SEE ARCHITECTURAL DRAWINGS FOR RATING. PENTRATING OR CEILING/FLOOR MINERAL /WOOL BACKING RATED DETAIL MATERIAL. DUCT MOUNTED VC, 4 -- F &I ANY NEEDED RELAYS /HOUSING ETC. , -..3 -�i../ `` SMOKE DETECTOR REMOTE ANNUNCIATOR / RESET SYS SENSOR, LOCATED NEAR MANAGERS (NOT SHOWN). PROVIDE PHENOLIC E LATE I pIICATING SMOKE DETECTOR". . EM MAR 042008 PERMIT CETEF _- _ . ,, • CO (x� , ' 0` '� w.. 6�. i1,ee � = - "�'� .. d ,�a.� is �.H At °1\i �, `° °• .3. rev EXPIRES SK TYP DUCT DETECTOR DETAIL NTS F &I ANY NEEDED RELAYS, ETC. (NOT SHOWN). n� .. .... .. _ STARBUCKS COFFEE COMPANY 2401 UTAH AVENUE SOUTH SEATTLE, WASHINGTON 98134 (206) 318 -1575 THESE PLANS AND SPECIFICATIONS. AS WELL AS STARBUCKS' NAME AND LOGO, TRADEMARKS AND DESIGNS ARE THE EXCLUSIVE PROPERTY OF STARBUCKS CORPORATION. ANY REPRODUCTION. MODIFICATION. DISCLOSURE AND /OR USE OF THESE MATERIALS OR ANY PORTION OF THEM) WITHOUT STARBUCKS' PRIOR WRITTEN CONSENT IS STRICTLY PROHIBITED. CONSULTANTS AER ENG INEERS 11155 120TH AVE. N.E. SUITE 200 KIRKLAND, WA 98033 (425) 739 -6051 (425) 739 -7362 AERI23 @AOL.COM REV DATE DESCRIPTION 02 -26 -08 LL /CITY COMMENTS 03 -03 -08 LANDLORD REVISIONS STARBUCKS COFFEE Q Ct7; 411- 0 Ww Z Z LIJ 0 U= 0 cr) o w d co oo r H z 0 Z z 0 PROJECT #: 12197-001 ISSUE DATE: CHECKED: DESIGNED: DRAWN: 01/28/08 JOHN BEEBE CHRIS RENSCH SHARON HARRIS SHEET TITLE ELECTRICAL 8 LIGHTING DETAILS SCALE: (DO NOT SCALE DRAWINGS) SHEET NUMBER E4.0