Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-1357 - CITY OF TUKWILA - CITY HALL
CITY OF TUKWILA 6200 SOUTHCENTER BL ELO8-1357 Parcel No.: 0003200005 Address: Suite No: Cityf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 6300 SOUTHCENTER BL TUKW ELECTRICAL PERMIT Permit Number: EL08 -1357 Issue Date: 10/24/2008 Permit Expires On: 04/22/2009 Tenant: Name: CITY OF TUKWILA - CITY HALL Address: 6200 SOUTHCENTER BL , TUKWILA. WA Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD , TUKWILA WA Contact Person: Name: BILL BONNER Address: 4326 PACIFIC HY , BELLINGHAM WA Contractor: Name: BONNER ELECTRIC INCORPORATED Address: PO BOX 31548 , BELLINGHAM WA Contractor License No: BONNEEI967LQ Phone: Phone: 360 - 756 -0798 Phone: 360 - 738 -1940 Expiration Date: 07/08/2010 DESCRIPTION OF WORK: REMOVE EXISTING GENERATOR, ATS & FEEDERS FROM EXISTING STANDBY GENERATOR, AM, SERVICE RATED DISCONNECT, NEW MDS. INSTALL NEW 225 KW FEEDERS Value of Electrical: 109,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: $2,012.50 National Electrical Code Edition: 2005 Date: 10- L2( off I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform e of work. I am authorized to sign and obtain this electrical permit. Signature: Date: / 0% q(CtP Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1357 Printed: 10 -24 -2008 Parcel No.: 0003200005 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6300 SOUTHCENTER BL TUKW CITY OF TUKWILA - CITY HALL PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1357 ISSUED 10/16/2008 10/24/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: f Print Name: : (� 20 ►'l h Date: I (U/2 4 7 doc: Cond -Elec EL08 -1357 Printed: 10 -24 -2008 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwwci.tukwila.wa.us Electrical Permit No. •E g' 13E7 POO.- )15" Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: Property Owners Name: Mailing Address: foix-k in tee E King Co Assessor's Tax No.: 30C 3) 0 ' 000 5 Suite Number: Floor: New Tenant: ❑ Yes R..No City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: i \ - C .Y\ tr'— ga Ete( -4r%L. Mailing Address: Li 31 61 ?a �� �Z A',"` I 13e U; E -Mail Address: 1 I iaU►'mNey- d 11- n..t,vi „ Co ►r►^ Day Telephone: (3'40) 75-70 — O 71 9 cvl� LAN- 9 S. z Z' ,ty State Zip Fax Number: (360) 15-1 - 0 4"s-z_._ ELECTRICAL CONTRACTOR INFORMATION Company Name: ECr la ear- f krr L . . Mailing Address: ti U(4 ?act- .tit— 14-..v...1 I .. Si YNCJ lg,y, U' 9 QZ2 ' t Cty State Zip Contact Person: 'gill l©4h.er //1414 ,E. I ‘-re,.., Day Telephone- CO) °75-6 — 07 9? E -Mail Address: b 1 i l fi:)) !ao n n v- e 1:42e,-4- r : L-h (Al , Lb Fax Number: Uo) 71(y - o es-z_ Contractor Registration Number: 13O IVA/EE in 7.1._ Q Expiration Date: Z 0 / l 9 t>0 P Valuation of Project (contractor's bid price): $ /O Scope of Work (please provide detailed information): Gv -4614 ,fir/ f• f9Kn /741 "171-ede✓I Will service be altered? k Yes ❑ No Type of Use: Type of work: ❑ New El Addition ❑ Service Change ❑ Remodel ❑ Low Voltage Generator ❑ Fire Alarm ❑ Telecommunication Adding more than 50 amps? ❑ Yes No Property Served by: Puget Sound Energy ❑ Seattle City Light H:\Applications\Fonns- Applications On Lineal -2007 - Electrical Permit Application.doc bh ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: IDate Application Accepted: 'v Day Telephone: / /WA' Ci Date Application Expires: Date: /WaoO (��c) 7.51 -o75f State Zip Staff Initials: If\ Applications \Forms- Applications On Line \4-2007 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http. / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 0003200005 Permit Number: EL08 -1357 Address: 6300 SOUTHCENTER BL TUKW Status: PENDING Suite No: Applied Date: 10/16/2008 Applicant: CITY OF TUKWILA Issue Date: Receipt No.: R08 -03536 Payment Amount: $2,012.50 Initials: WER Payment Date: 10/16/2008 10:29 AM User ID: 1655 Balance: $0.00 Payee: BONNER ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11444 2,012.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 1,610.00 402.50 Total: $2,012.50 r1nr. RPraint -OR Printari 1O- 1R -2n(1R Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 3597000282 6200 SOUTHCENTER BL TUKW CITY OF TUKWILA - CITY HALL RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -1357 ISSUED 10/16/2008 10/24/2008 Receipt No.: R09 -01221 Initials: User ID: Payee: JEM 1165 Payment Amount: Payment Date: Balance: $360.00 08/04/2009 11:48 AM $0.00 EBENAL GENERAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA - Authorization No. 007176 360.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING INVESTIGATION 000/322.800 360.00 Total: $360.00 PAYMENT RECEIVED doc: Receiot -06 Printed: 08 -04 -2009 INSPECTION NO. INSPECTION RECORD Retain a copy with permit t og l357 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 15a- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro' WIC (All 1 Amoir Ifr Type of Inspection: n G 00 Ad . res 10200 5.c-. 81.-- Date Called: --� Special Instructions: Date Wanted: D ViO P.m- Requester: Phone No: IXI Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Re&xi0A15 r11tDE K. Inspector: Date: to inspect fee m ' O p n $60.00 REINSP�ECTION FEE RE(iUIRED. Prior %st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION : K- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 CtA3 -135 Project:C 1 t l.( C 1f I .l6a4 Type of Inspection: 2100 ) KO. s cti j on) HL . Address: 6 2oo 5.C. 6L . Date Called: Special instructions: Date Wanted: S r S ll� a.m. p- Requester: Phone No: IDApproved per applicable codes. JJ Corrections required prior to approval. S COMMENTS: ) KO. s cti j on) HL . L C-t. ca. frtAX. St/2\W St/2\W N PAI r7 3�LNISEL, 2 u JL A ( S ame_tqLS L) eft- Most Ste 4i6C bi J46c-r _� Inspector: . Date: cgl i z O $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee mutt be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: % gf7j.,r`L4 6� Type of Inspection: 7001.. Address: b?� S -c- • fit. Date Called: Special Instructions: Date Wanted: Q g P.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. 1 COMMENTS: • Jtr 6•Jeozq t zt Inspector: Date: i ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule rein pection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit I16g13s1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project:// /" f�, 0( "r` 1...,11 1'�s�/ � Type of Inspection: �0 014. — a-AkizirroicAeodA/NAki Address: 4Zoo s.c.. tL. Date Called: - MAW t k t PAO ATS i i rli4T ohl3 Special Instructions: Date Wanted: o Olif m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. I` COMMENTS: 014. — a-AkizirroicAeodA/NAki - C(RoJA/DIALI /6 IA/t) yyr MVIGE - MAW t k t PAO ATS i i rli4T ohl3 Inspector: 74,Jetc, Date: 03/04 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 4.a..•it.,,_...a -.may 0.404W- ita .igitt g.aa,•era1- ,.,. =__. INSPECTION NO. INSPECTION RECORD Retain a copy with permi PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 7WXttliM c47-7 iti9L Type of Inspection: -270/ Address: (JC') v ;fJ , , Date Called: l Special Instructions: ate Wanted: %a.m. p.m. Requester: Phone No: oved per applicable codes. Corrections required prior to approval. MMENTS: lifiG3//t). 7a 6/' 1 -7 /4 r - / / 9 dfi&,f/ `" r 91 X4,6 Inspeit/W itgeroWn1(617' Date: 7/5//�� El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ~OA- Oe ‘Jimmtt tawl- REIMBURSEMENT AUTHORIZATION AND APPROVAL TO CONDUCT INSPECTION ACTIVITIES DURING OFF HOURS , Date: S Permit No. 'Et/ 199s1- Requested by A).\\D'' c,r Firm/Company: i. ; Project Name: Project Address/Location: Time of Off-Hours Construction Activity — From: Requested Time for Inspection: Contact Name: P 017:A Special Conditions for Consideration: To: arn/Pni, am/pm) Phone No ** Contractor will be charged a minimum of four (4) hours inspection time for any off-hours inspection work at $90.00 per hour. This is to be paid at time of request. ** The undersigned, as an authorized representative of the above firm, hereby agrees to reimburse the City for its overtime inspections on the above referenced project. A separate invoice will be issued for all inspection time in excess of four (4) hours. ,., Signature: Print Name: .■"" \z(' e . JUL & 1 2009 PERMIT caw Reviewed by: Approved: Remarks: Disapproved: PAPormit ContenemplatesTormslAfter Hour Inspection Requestdoo • • City of f Tukwila Jim Haggerton, Mayor March 12, 2009 Department of Community Development Jack Pace, Director Randy Reynolds Bonner Electric PO Box 31548 Bellingham, WA 98228 RE: Request for Extension Electrical Permit No. EL08 -1357 City of Tukwila (City Hall) — 6200 Southcenter BI Dear Mr. Reynolds, This letter is in response to your written request for an extension to Permit Number EL08 -1357. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. The City of Tukwila Building Division will be extending your permit an additional 180 days from the date of expiration, through October 19, 2009. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, ifer Marshall it Technician File: Permit No. EL08 -1357 P:\Permit Center\Extension Letters \Pemrits\2008\EL08 -1357 Permit Extension.doc jem 6300 Southcenter Boulevard. Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • Bill Rambo - permit extension • Page 1 of 1 4:420s2AA •:121LI Ma7mmml11q} rt atc:aresrZwr439AMInL• •X:rr41:20.•ad na:ZMI10 1MATMUISNawecc w AlxdliVeL m From: To: Date: Subject: Randy Reynolds 03/09/2009 1:54 PM permit extension This is a request for extension of 180 days on EL08 -1357. This project has been delayed do to design modifications. Thank you for your consideration. Randy Reynolds Bonner Electric 360 - 319 -3626 Windows LiveTM: Keep your life in sync. Check it out. 4K, b6gte/gi e7/10.cfr /6007 4eA46 0,07 iftE0E4 W60 CITY of TUI Wt1A MAR 0 9 2009 PERMIT CENTER eP o�1221c �- Pi r I file: / /C: \temp\XPGrp Wise \49B 51 F81 tuk- mail6300 -po 10013675 3 8117001 \GW } 00001.11... 03/09/2009 • 03 -02 -2008 BILL BONNER 4326 PACIFIC HY BELLINGHAM WA 98228 Jim Haggerton, Mayor epartment of Community Development Jack Pace, Director RE: Permit No. EL08 -1357 6200 SOUTHCENTER BL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/22/2009 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall 't Technician xc: Au2 Permit File No. ELO8 -1357 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • PER IT C 1ORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1357 DATE: 10 -16 -08 PROJECT NAME: CITY OF TUKWILA - CITY HALL SITE ADDRESS: 6200 SOUTHCENTER BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: C p Bu ding Qivision Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 10 -21 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11 -18 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • Page 1 of 2 Electrical Contractor A business licensed by LFtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip BONNER ELECTRIC INCORPORATED 3607381940 PO BOX 31548 BELLINGHAM WA 98228 County WHATCOM CORPORATION EBENAL GEN SPEC PROJ INC Business Type Parent Company UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602355799 ACTIVE BONNEEI967LQ ELECTRICAL CONTRACTOR 7/8/2004 7/8/2010 BONNEWH972N2 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License BONNEWH972N2 Name BONNER, WILLIAM HAROLD Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BONNER, WILLIAM H AGENT 06/18/2004 EBENAL, DAVID C PRESIDENT 06/18/2004 Bond Information Bond Bond Effective Expiration Cancel Impaired ( Bond Received https: / /fortress.wa. gov /lni/bbip/Detai 1. aspx ?License= BONNEEI967LQ 10/24/2008 �E . eCC_IPt/ Per ni No .ge(1:18.116i Piar ro\fiew cpproval is sub;ect to error and or. • APF '.'::' of construction document; does not aub see the o ation of any adopted codo or ordinance. 11,-L%-r.:-Ant o� Lpproved Field Copy and concretions is ac nawic oe.d: CITY OF TUKWILA ANDBY POWER UPGRADES -YEAR ONE By Date (y2 fI DP CITY PROJECT NO. 06 -BG01 BUDGET ITEM NO. 303.00.594.190.41.72 TAC PROJECT NO. PDO6P0051 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. i City of Tukwila BUILDING DM SON VACINITY MAP DRAWING INDEX TO-1 TO-2 E1 -1 El -2 (1.3 E2 -1 E2 -2 E2-3 (3-1 E3-2 (4-1 E4-2 E4-3 5-1 ,yRa - J • FIRE STATION #52 a 5900 S. 147TH ST. TUKWILA, WA 98188 TITLE SHEET AND DRAWING INDEX LEGEND AND :ENERAL NOTES CITY HALL P,RTI AL PLANS CITY HALL ONE -LINE DIAGRAMS CITY HALL LSAD SUMMARY AND PANEL SCHEDULES FIRE STATION /52 PARTIAL PLANS FIRE STATILI'! /52 DETAILS FIRE STATION /52 ONE -LINE DIAGRAMS FIRE STATION 03 PARTIAL PLANS FIRE STATION 1153 ONE -LINE DIAGRAMS, LOAD SUMMARY, ELEVATION DETAIL FIRE STATION 154 PARTIAL PLANS FIRE STATION 154 DETAILS FIRE STATION /54 CNE-L I NE DIAGRAMS, SCIEDULE, MID DETAILS TCR - . DETAILS D C PR 2 Z00 REVIEWED FOR CODE COMPLIANCE E NFPA 7 OCT 2 2 0B B FIRE STATION #53 a 4202 S. 115TH ST. TUKWILA, WA 98188 di ELO9 1357 FIRE STATION #54 a 4237 S. 14411.1 ST. TUKWILA, WA 98188 i 2 Title Sit�taa�, �ai9�o4,la1eX-�,��, ,...... Provided to Builders Exchange of WA, Inc. For usage Conditions _Agreementsee.www.bxwa.com,Always Verify-Scale- 3 RECEIVED OCT 16 PERMIT CENTER II I'; 4 Copyright 0 2007. TAC. M Rights Rpne . D C • I - R - • - - g= t:i ELECTRICAL SYMBOLS G GENERAL NOTES A ABBREVIATIONS g EM P 1 1 . PROVI DE ELECTRI CAL I NSTALLATI ON I N ACCORDANCE WI TH A ALIERNATI NG CURRENT a ( a WP T EXISTING WORK OR EQUIPMENT (THIN U / /, / / /` / /` / / /��/ EXISTING WORK TO BE REMOVED 4 •1411" < r R 0 EQUIPMENT CONNECTION (EQUIPMENT NAME, LOAD. I MAU 1. 12KVA,480.3 VOLTAGE, AND PHASE INDICATED) • RACEWAY ONLY S INDICATES DIRECTION OF CUTTING CO R SECTION POWER OR UGHTNG BRANCH CIRCUIT INDICATING C ALPHABET ■ SECTIONS & ELEVATIONS o /111/11 AgrAB T DRAWING CONTAINING SECTION, ELEVATION, 1 DRAWNG CONTAINING PLAN AT WHICH SECTION, —� �— B FLAG NOTE � �� C CIRCUIT BREAKER C EXISTING RACEWAY S I AVAILABLE SHORT CIRCUIT CURRENT, 3 PHASE, N . I a 5 TO -2 Legend and'€erteratliottss^ - "o- ,-41' Provided to Builders Exchange of WA,. Inc. For usage Conditions Agre rnent see www.bxwa.com - Always_Verify Scale_ 2 3 CDPYNyR O 14D7, TIC, AD RW` 1 D B A MECHANICAL EQUIPMENT GENERATOR FUEL TANK 2 3 PAD MOUNT UTIUTY TRANSFORMER • CT & METERING \\ • / CABINET \ \ \\ \ \\ \ • • \; \ \\ ` • • ATS STANDBY GENERATOR wP 47 41"P WP N 1 MAIN DISTRIBUTION SWITCHBOARD (MDS) PULL BOX ABOVE MDS • TO PANEL EM DEMOLITION PARTIAL FLOOR PLAN SCALE 1/4. 1• -0• E1 -11 E5 -1 CONCRETE PAD UNDERGROUND FUEL UNE TO BE DEMOLISHED. SEAL ALL PENETRATIONS TO BUILDING AND FLOOR. PATCH WALL AND PAINT TO MATCH EXISTING. f0 STUB -UP CONDUIT TO NDMA 3R J -BOX. PROVIDE J-BOX AT +24 AG t7 MAINTAIN MIN. 6' -0• CLEARANCE TO MECHANICAL EQUIPMENT. 1© PROVIDE WP GFCI RECEPTACLE MOUNTED ON UNISTRUT AND SUPPORTED fROM GENERATOR PAD. MOUNT RECEPTACLE +16 ABOVE CONCRETE PAD. PAD MOUNT UTILITY TRANSFORMER J.G. SECONDARY SERVICE FLAG NOTES: • REMOVE DOOR PRIOR TO DEMOUTON. DOOR FRAME TO REMAIN. • TERMINATE GENERATOR EXHAUST STACK 10' FROM PROPERTY UNE AND 10' FROM BUILDING AS REQUIRED BY IMC SECTION 501.2.1 DEMOUSH SERVICE ENTRANCE CONDUCTORS FROM SECONDARY OF PSE'5 TRANSFORMER TO MAIN DISTRIBUTION SWITCHBOARD AS SHOWN. CONDUITS TO REMAIN. COORDINATE WITH PSE TO COMPLY PITH THE NECESSARY NATE REQUIREMENTS. 11- 253 - 395 -6911) DEMOUSH GENERATOR. FUEL TANK. AND ALL ASSOCIATED EQUIPMENT INCLUDING FEEDER BACK TO ATS COMPLETE • DEMOUSH ATS AND FEEDER BACK TO MDS COMPLETE P SERVICE ENTRANCE FEEDER ROUTED VIA MDS TO SE DISCONNECT. FEEDER FROM ATS TO MDS. \\ \ \ \\ \ \\ •• \ \ \ CT & METERING ENCLOSURE SE DISCONNECT STANDBY FEEDERS CONTROLS MAIN DISTRIBUTION SWITCHBOARD, (MDS) PULLBOX ABOVE MDS •\ TO BATTERY CHARGE 7225 KW STANDBY GENERATOR c>. EQUIPMENT PANEL 1(2) -1 PANEL 1(2) -1 BLOCK HEATER WP WP YT YT A TS EM \ TO ANNUNCIkthR PANEL 1•C.- 3#T0.1#10EGC 1•C. FOR GENERATOR CONTROL (2)3"C- 4#35OKCMIL.1 j1 EGC El -1 GENERATOR ANNUNCIATOR PANEL PANEL 1(2) PANEL 1 REVISED PARTIAL FLOOR PLAN SCALE: 1/4• - 1' -0• APR D RECEIVE F ,OCT 162008 PERMIT CENTEr GRAPHIC SCALE : 14'.1• -CF 0' r 4• 8' 12' DESCRIPTION 2 SUBMISSION / REVISION DRAWN BY R. NAZZARD CHECKED Bn H. GIESE DESIGNED BY. K. NISTRY APPROVED BY 8. GIESE DATE■ JUTE 2608 PROJECT PD06Po051 CITY HALL PARTIAL PUNS El -1 SHT. 3 OF 14 E1-1 City {JAILEagjaJRAE$� 1 1 2 Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www bxwa.com - Always Verify Scale _ 3 4 S CapyrIQM O 2007. TIC, All Rlye. Reamed. D C B A TO PSE ELECTRICAL VAULT CT AND METER CABINET L 2 1225 TKRVAANSFORMER 112.5KV - 208Y/120V, 3- PHASE, 4 W 29100 r 00/31AB (5) 3 "- 48500KCMIL EGC Q7 L 3 MAIN DISTRIBUTION SWITCHBOARD (MDS CH) 1600A. 208Y/120V,30,4W 22k AIC (225/3 (100/3 (100/3 (100/3 LTR GENERATOR 35KW,43.75KVA 208Y/120V,3,4W PANEL PANEL 0 PANEL EM DEMOLITION ONE —LINE DIAGRAM .(2)3 C- 4/350CCMK,1/1EGC TO PSE ELECTRICAL VAULT PSE TAAN2FORµERR r v 12.50V - 208Y/12CV 3- PHASE. 4 W L CT AND METER CABINET- 150/3 150/3 PANEL A PANEL C SCALE NONE CIRCUIT BREAKER DISCONNECT 600A, 3P, SE RATED FLAG NOTES: DEMOLISH EXISTING SE CONDUCTORS FROM SECONDARY SIDE OF PSES TRANSFORMER TO MAIN DISTRIBUTION SWITCHBOARD, CONDUITS TO REMAIN. REMOVE EXISTING 1600A MAIN CIRCUIT BREAKER AND PROVIDE SOUD COVER. COORDINATE ALL SERVICE RELATED WORK WITH PSE AND COMPLY WITH ALL NECESSARY REQUIREMENTS DEMOUSH A15 AND FEEDER BACK TO MDS COMPLETE. • PULL CONDUCTORS BACK TO PULL BOX LOCATED ABOVE MDS TO FAOUTATE RE -FEED FROM PNL -EM. DEMOLISH CONDUCTORS FROM ATS To MDS. • REMOVE GENERATOR FUEL TANK LL AND A ASSOCIATED EQUIPMENT INCLUDING FEEDER TO ATS COMPLETE RETURN GENERATOR BACK TO OWNER. PROVIDE SERVICE ENTRANCE CONDUCTORS FROM SECONDARY OF PSES TRANSFORMER TO MAIN DISTRIBUTION SWITCHBOARD, FROM MAIN DSTRBUTION SWTCHBOAD TO BE DISCONNECT AS SHOWN COORDINATE WITH PSE TO COMPLY WITH ALL NECESSARY REQUIREMENTS UTIUZE EXISTING CONDUITS TO PULL-IN NEW CONDUCTORS FROM TRANSFORMER TO MDS. CAP AND ABANDONED UNUSED CONDUITS PROVIDE SOUD NEUTRAL CONNECTION BETWEEN GENERATOR NEUTRAL AND UTIUTY TRANSFORMER NEUTRAL TERMINATE EXISTING PANEL EM CONDUCTORS TO BREAKER AS SHOWN. NOT USED. PROVIDE (2) 3/4- DIAMETER 10' -0- LONG COPPER CLAD STEEL GROUND R00 FOR GENERATOR EQUIPMENT GROUND. USE EXOTHERMIC WELD. t0 PROVIDE ALL NECESSARY CONNECTIONS WITH CABLES TO EXISTING BUS. Ilt> (2)3-C -4 j35oKC AIL,1111 ECC (2)3-C- 4/350KCMIL,I#1EGC GENERATOR CIRCUIT BREAKER 3 POLE STANDBY GENERATOR SET I /-\ I I _ — l✓ 225KW.208Y/120V,30,4W o o I 600A MAIN CIRCUIT BREAKER - Lm i1 249811 27349 I▪ Q 1 225/3 (225/3 (350/3 (350/3 PANEL 2 PANEL 3 PANEL PANEL 4 1 L 1 r I L_ IU iQ J u 236661 ATS 208V, 3P, 600A. SE RATED• (2)3- C- 4/350KCMILI/1EGC (225/3 7..CONOUIT C41401 W1RESSEXIISTING 100/3 PANEL MAIN DISTRIBUTION SWITCHBOARD (MDS CH) 600A, 208Y/120V,30,4W 22K AIC 100/3 PANEL D 100/3 PANEL EM 150/3 PANEL A REVISED ONE —LINE DIAGRAM 150/3 PANEL C 225/3 PANEL SCALE: NONE 225/3 PANEL 3 350/3 PANEL PANEL 1 (2) 350/3 PANEL 4 21606 1 J RECEIVED X16 PERMIT CENTER 1 6 SUBMISSION / REVISION DRAWN BY R. NAZZARD DECKED 3Y6 IL GIESE DESIGNED BY, K. NISTRY APPROVED BY B. GIESE DATE■ JUNE 2008 PROJECT PD06P0051 CRY HAIL ONE -UNE DIAGRAMS E1 -2 SHT. 4 OF 14 2 City tia,10,0a4,J29mEna.. -,«, Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always Verify Scale_ 3 4 5 Copyright 0 2007, TAG, M Rights Resoled. 1 D C B A 2 3 1 LOAD SUMMARY CRY HALL. PANEL: MAIN DISTRIBUTION PANEL (MOP CH) EMIT/4010AD UTILITY PEAK DEMAND 168.0 KVA NEC 220.87 ADJUSTMENT FACTOR (25 %) 42.0 KVA ADJUSTED PEAK DEMAND 2100 KVA ADDED LOAD 3.88 KVA la[E E1 11:1 /OR ADDED LOAD BREAEDDEEI TOTAL CALCULATED PEAK DEMAND AMPERES 0 208 VOLTS. 3 PHASE ISOM 0711.1, PERE moan, PROVIDED BY DEB. 213.8 KVA 544.4 AMPS PANEL SCHEDULE DESIGNATION Panel 1 208 YI 120 VOLTS 3 PHASE. 4 WRE NOTES: SQUARE D LOCATON CITY FULL ELEC RM 400 AMP MAIN LUG ONLY CATS 08L44241 FED FROM MOS 100% NEUTRAL 10000 AC SYM CR S OCT BKR CIRCUTT DESCRIPTION LOAD KVA P LOAD H KVA CR 8 ENT BKR CRCUIT DESCRIPTION 1 80/3 AR HANDLER 01 a 2 5013 AR HANDLER 03 b 1 I 1 b 1 1 j D 6 1 1 5 1 I • 4 40,3 SPACE ONLY 3 50,3 DUCT HEATER 02 9 1 I to 10 12 I_____I 1 SPACE ONLY c 1 SPACE ONLY a I 1 VAOJM - OUTSIDE BLDG 5 70/3 RECEPTS a 6 0012 WATER HEATER 15 1 Recopade at 009.1830 1.38 9 18 1 J 17 I 0eneramr 000k Heater 250 c 8 20/2 UNABLE TO DETERMINE a 20 I I 7 SPACE ONLY b 22 SPACE ONLY SPACE ONLY b 10 201 RECEPTS 9 20/2 UNABLE TO DETERMINE c 12 20/1 RECEPTS a 14 20/1 REFRIG RM 101, HEATER RM 104 27 I 1 11 20,1 HOT WATER UNDER SMC RM 101 SPACE ONLY D 16 20/1 VENDING MACH@E c 18 20/1 RECEPTIBULDING SIGN RM 001 13 20/1 DISHWASHER RM 101 15 20/1 MICROVEN RECEPT RM 101 SPACE ONLY a 20 20/1 GENERATOR RM RECEPT b 22 20/1 GENERATOR OUTLET 17 20/1 HEAT CONTROL. RM 1 19 20/1 MICROVEN SPACE ONLY �0''► c 24 20/1 RECPPTS RM 001 a 28 20/1 IRRIGATION SYSTEM 21 20/1 LTG RM 10 SPACE ONLY b 20 2012 FOUNTAIN FRONT 23 20/2 JAPANESE FOUNTAIN SPACE MY PERMIT 25 1 1 c 30 I I SUBFEED PNL 1(2) LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY(CONTI CONNECTED CALCULATED UG1iTND 0.00 KVA 0.00 KVA (125%) HEATING 6 MISC 000 KVA 0.00 KVA (100%) LARGEST MOTOR 0.00 KVA 0.00 KVA (125%) NON-COINCIDENTAL 0.00 KVA 0.00 KVA ( 0%) 01/ER MOTORS 0.00 KVA 0.00 KVA (100%) KITCHEN EOPT 0.00 KVA 0.00 KVA ( 85%) RECEPTACLES 3.88 KVA 3.88 KVA (50%.- 10KVA) CONTINUOUS 0.00 KVA 0.00 KVA (125%) TOTAL 3.88 KVA 3.88 KVA 10.77 AMPS 10.77 AMPS LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY (CONT) CONNECTED CALCULATED LIGI4T01G 0.00 KVA 0.00 KVA (125%) HEATING 6 MISC 0.00 KVA 0.00 KVA (100%) LARGEST MOTOR 0.00 KVA 0.00 KVA (125%) NONCONCDENTAL 000 KVA 0.00 KVA( 0%I OTHER MOTORS 0.00 KVA 0.00 KVA (100%) KITCHEN EOPT 0.00 KVA 0.00 KVA ( 85 %) RECEPTACLES 0.00 KVA 0.00 KVA ( 50%> 10KVA) CONTINUOUS 0.00 KVA 0.00 KVA (125%) TOTAL 0.00 KVA 0.00 KVA O00 AMPS 0.00 AMPS Re/670N LATE 58202008 PANEL SCHEDULE DES/GNAT:N Panel 1(2) 208 Y/ 120 VOLTS 3 PHASE, 4 WRE NOTES: BOLD NDCATES NEW WORK LOCATION CITY MU. ELEC RM 400 AMP MAN WG ONLY Added bad b 2.7% of the FED FROM PANEL 1 100% NEUTRAL 10000 AC SYM capacity M the pang. CR S CKT BKR CIRCUIT DESCRIPTION LOAD KVA P LOAD H KVA CR 6 CKT BKR CIRCUIT DESCRIPTION 1 20,3 AR HANDLER 02 e 2 40/3 HEAT PUMP 03 3 1 1 b 4 1 j E 6 1 I 5 1 1 a 8 40,3 HEAT PUMP 02 7 50/3 HEAT PUMP 01 9 1 5 c 10 12 I_____I 1 1 11 1 a 14 201 VAOJM - OUTSIDE BLDG 13 20,1 RECEPTS 5 18 SPACE ONLY 15 20/1 Recopade at 009.1830 1.38 c 18 SPACE ONLY 17 3011 0eneramr 000k Heater 250 19 SPACE ONLY a 20 SPACE ONLY 21 SPACE ONLY b 22 SPACE ONLY 0 24 SPACE ONLY 23 SPACE ONLY 25 SPACE ONLY a 28 SPACE ONLY 27 SPACE ONLY b 28 SPACE ONLY 29 SPACE ONLY c 30 SPACE ONLY 31 SPACE ONLY a 32 SPACE ONLY b 34 SPACE ONLY 33 SPACE ONLY 35 SPACE ONLY c 36 SPACE ONLY �0''► 37 SPACE ONLY • 38 SPACE ONLY OCT V 7 ) b 40 SPACE ONLY 39 SPACE ONLY c 42 SPACE MY PERMIT 41 SPACE ONLY LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY(CONTI CONNECTED CALCULATED UG1iTND 0.00 KVA 0.00 KVA (125%) HEATING 6 MISC 000 KVA 0.00 KVA (100%) LARGEST MOTOR 0.00 KVA 0.00 KVA (125%) NON-COINCIDENTAL 0.00 KVA 0.00 KVA ( 0%) 01/ER MOTORS 0.00 KVA 0.00 KVA (100%) KITCHEN EOPT 0.00 KVA 0.00 KVA ( 85%) RECEPTACLES 3.88 KVA 3.88 KVA (50%.- 10KVA) CONTINUOUS 0.00 KVA 0.00 KVA (125%) TOTAL 3.88 KVA 3.88 KVA 10.77 AMPS 10.77 AMPS RISISEN CAM 5202009 IVED 6 CENTEP a a DRAWN 8Y. R. NAZZARD. CHECKED 80 a GIESE DESIGNED 31■ K. /WIRY APPROVED 8Y B. GIESE DATE. JUNE 2008 PROJECT P006P0051 CRY HALL LOAD SUUVARY AND PANE. SCHEDULES E1.3 SHT. 5 OF 14 E1 -3 City 1..1'11 Loa �T�c{ par1Q' �.i1QL' l 2 ' d�e� .+7k��R41= Ya.�1X`idA`�- ]SGMWGY eDS7m/mDe aw a¢n Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always Verify Scale 1 3 4 1 5 Cops10/4 0 2007, TAG AO FOOT Maa /ed. D c B A 1 2 3 O-- c O APPROXIMATE LOCATION OF ELECTRICAL UTILITY SERVICE VAULT- C� MOVE STORAGE SHED TO NEW LOCATION AFTER COORDINATING W111 PROJECT MANAGER AND FIRE DEPARTMENT STAFF WORK AREA S "ORAGE HOSE TOWEP P- 1,3,5, APPARA'uS ROOM 34HP,240V,30 34HP,240V,30 DEMOLITION PARTIAL FLOOR PLAN D SCALE: 1/4' t• -0' CONCRETE PAD E2_1 ES—t 5OKW STANDBY GENERATOR`+ I STANDBY FEEDER E2 -1 E —2 2 "C- 3#3/0, 1/4 EGC APPROXIMATE LOCATION OF ELECTRICAL UTILITY SERVICE VAULT AREA FLAG NOTES: DEMOUSH EXISTING ROLL —UP DOOR MOTOR AND )40TOR STARTER PULL CONDUCTORS BACK TO POWER SOURCE. CONDUITS TO REMAIN. CONTROLS BATTERY CHARGER Ej. REPLACE EXIS71NG 240V 3 —PHASE MOTOR AND STARTER WITH NEW BLOCK HEATER 240V 1 —PHASE MOTOR AND STARTER. COORDINATE REQUIREMENTS WITH MOTOR /STARTER SUPPUER. R & S AUTOMATION 1- 503 - 774 -8708. PROVIDE WP/ GMT PROTECTED RECEPTACLE MOUNTED ON UNI —STRUT SUPPORTED FROM GENERATOR PAD. MOUNT RECEPTACLE +18' ABOVE CONCRETE PAD. TERMINATE GENERATOR EXHAUST STACK 10' FROM PROP UNE AND 'C, FOR GENERATOR CONTROLS 1.-0" MIN 10' FROM BUILDING AS REQUIRED BY IMC SECTION 501.2.1 STUB —UP CONDUIT TO NEMA 3R J—BOX. PROVIDE J—BOX T 24'AG. F1 TYP) ATS $1"C TO GENERATOR ANNUNCIATOR PANEL 1' C -3/12 1,12 EGC, MDP FS#22 -5,7 MDP FS/52 ----REVIEWED OR CODE CD Op SEC R1Fp�` OCi 2 2 2008 Ot TuloNilIO 11.01 DI% 1 HOSE TOWER L PANEL L DORM BATH ROOM SERVICE ENTRANCE RATED DISCONNECT SWITCH, 400A, 2 POLE 3N EXISRNG2GGNDU T9c 3N EXISTING CONDUIT C S ROCM PPARA P -1,3 • © P-2,4 YNP,240V,10 — 1,3,2,4 E2-1 E2— 44HP,240V,10 PANEL P 1 C TO ATS FOR CON -OL WIRES GENERATOR ANNUNCIATOR PANEL REVISED PARTIAL FLOOR PLAN D SCALE 1/4' WATCH OFFICE F D OCT 11620 PER 3" CENTER GRAPHIC SCALE 0' 2' 4' e' 12' SUBMISSION / REVISION DRAVN DT, R. NAZZARO CHECKED !Y. B. GIESE DESIGNED BT, K. NISTRY APPROVED BY B. GIESE DATE, JUNE 2008 PROJECT PD06P0651 F RE STAnoN /52 PARTIAL PUN$ E2.1 SHE, 6 OF 14 E2 -1 Fire atati2 ,f� 2D�Yr IlI,E .S. ,1 1 2 Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always Verify Scale 3 4 5 Copyright 0 2001, TAC, All Rights Removed. D c B A TO MOP FSg52 400 AMP 2 -POLE TO ATS SERVICE ENTRANCE RATED DISCONNECT SWITCH EXISTING 3' SERVICE ENTRANCE CONDUIT TO MDP FS/52 FINISHED FLOOR REVISED ELEVATION SCALE 1• _ 1' -0" E2 -2 E2 -1 CONTINUOUS WARNING RED TAPE NON - DRIVING SURFACE '1= III —III - 1I =1I1= 16 MIN, 30' MAX —_ DRIVING SURFACEESS - 111 =1 _111_ /. SCHED 40 PVC CONDUIT (TYP) 0 1r BACKFILL 90% COMPACTION ALC 1. RESTORE SURFACE BACK TO ORIGINAL CONDITION. 2. SEE PLAN FOR CONDUIT SIZE AND OUANTITY. DIRECT BURIED DETAIL % SCALE NONE E1- 1,E2- 1,E3 -1 E2 -2 E2 -2 Fire Station 52aq lg, ,,,_T.„ ,,m, m_n V„ .,,,, Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement seer wv.bxwa om -.Always Verify Scale 2 DISCONNECT 200A, 2POLE PANEL 'L' DISCONNECT 200A. 3 POLE 11 7�s-ra�. %y %�0� 6l 7 �410/ • I wi iron /////A iiii i .rimk4 /,'i�li�; Ainiiain� ABANDONED COMM CABINET 2. -10" • EXISTING 3' SERVICE ENTRANCE CONDUIT ABANDONED COMM CABINET 20 RECEIVED OCT 1620 PERMIT CENTER FINISHED FLOOR 3 DEMOLITION ELEVATION SCALE 1' - 1' -O' 4 E2-.7.215-1 DESCRIPTION SUBMISSION / REVISION DRAVN DY. R. NAZZARD CHECKED BY1 B. GIESE DESIGNED Dn K. NISTRY APPROVED 8r & GIESE 5 DATE. J E 2009 PROJECT PDO6POO51 FIRE STATION /52 DETAILS E2 -2 SHT. 7 OF 14 Capp1QK O 2C07,1 AC. AD ROM R-a,ep. 1 D C B A 2 FLAG NOTE: DEMOUSH SERVICE DITRANCE CONDUCTORS FROM SECONDARY SIDE OF PSE'S TRANSFORMER TO SERVICE ENTRANCE DISCONNECTS AS SHOWN. CONDUITS TO REMAIN COORDINATE ALL SERVICE RELATED WORK WITH PSE AND COMPLY WITH AU- NECESSARY REQUIREMENTS PROVIDE SERVICE ENTRANCE CONDUCTORS FROM SECONDARY SIDE OF PSES TRANSFORMER TO SERVICE ENTRANCE DISCONNECT AS SHOWN. COORDINATE WITH PSE TO COMPLY WITH THE NECESSARY REQUIREMENTS. (CONTACT: NATE UNVILLE, 1- 253 - 395 - 6911). PROVIDE SCUD NEUTRAL CONNECTION BETWEEN GENERATOR NEUTRAL AND UTIUTY TRANSFORMER NEUTRAL EXISTING HIGH LEG CONFIGURATION TO BE ELIMINATED. PROVIDE (2) 3/4- DIAMETER. 10' -0- LONG COPPER CLAD STEEL GROUND ROD. FOR GENERATOR EQUIPMENT GROUND. USE EXOTHERMIC WELDS. 30 -Day Matering Point. 120/240V,18,3W TO PSE VAULT PSE TRANSFORMER 50 KVA 1::>r 1 12.5 KV- 120/240V 1 -PHASE (2) 3/4/O, 1/2 EGC USE EXISTING CONDUITS TO PSE VAULT IM (2) 414/0 AL 1g2 EGC SERVICE ENTRANCE DISCONNEC 200 AMP, 3 POLE 3 PSE TRANSFORMER (1)50 KVA,(1)25KVA,1 -0 TRANSFORMER 12.5 KV- 120/240V DELTA BANK (HIGH LEG CONFIGURATION) ' / /// - / Ar / / / / / / / / /// SERVICE ENTRANCE ���y��� ��� ��� ��������� CABINET I SERVICE ENTRANCE DISCONNECT 200 AMP, 3 POLE 240V,30 CENTER TAP 120V CENTER TAP (20V (HIGH LEG CONFIGURATION) DEMOLITION PARTIAL ONE -LINE DIAGRAM SCALE NONE SERVICE ENTRANCE RATED DISCONNECT 2 POLE n (2) 2-C- 3#4/0, 1/2 EGC 7ATS 400A 2 POLE 120V/240V,1 a, 3W r 1 1 GENERATOR CIRCUIT BREAKER 2 POLE I1 4811 i ISTANDBY La - -- J GENERATOR 50KW. 14 200* 20 /A2MAIN 0V,10,3W CIRCUIT BREAKER 2-C- 3/4/0. 1/2 EGC (2) 2-C- 3/4/0, 1/2 EGC I(1 6919 1 (200/2 (200/2 L_ J MDP FS/52 34118 400A MAIN BREAKER 1 20/240V,1 0,3W 2-C- 3e4/0. 1/2 EGC 120/240V,18,3W REVISED PARTIAL ONE -LINE DIAGRAM SCALE: NONE LOAD SUMMARY PANG: MAN DISTRIBUTION PANEL (MDP PSa52) EOM* LOAD. RECORDED 30-DAY PEAK DEMAND ON: 11(102687 24 CO KVA SEASONAL ADJUSTMENT FACTOR (1.34) 8.64 KVA SEASONALLY ADJUSTED PEAK DEMAND 32 94 KV n 12914 OF CURRENT MAX( NEC 220.87) 8.16 KVA ADJUSTED PEAK DEMAND 40 80 KVA ADDED LOAD 2888 KVA rase MAL SC rs45i roe ADDeo wAD are TOTAL CALCULATE) PEAK 091AND AMPERES ® 240 VOLTS. 1 PHASE 43.68 KVA 182 OC AMPS MAIN DISTRIBUTION PANEL SCHEDULE DESIGNATION MOP FS#52 240 / 120 VOLTS 1 PHASE. 3 WIRE NOTES: Maw Panel LOCATION NW Caner 400 AMP MAN CIRCUIT BREAKER FED FROM AT5 100% NEUTRAL 10000 AC SYM CIR 0 CKT BKR CIRCLETCESCRPTION LOAD KVA P H KVA 002 8 CKT BKR CIRCUIT DESCRIPTION 1 20012 Panel L 1.68 a 2 200/2 Pool P 3 1 1 b 4 I 1 5 2011 Receptacle at Generates 1.38 a 8 I SPACE ONLY 7 2011 Generator Bkcr Heater 1.50 D 8 202 SPACE ONLY 9 1 SPACE ONLY 4.30 a 10 1 SPACE ONLY 11 202 SPACE ONLY 11 b 12 4.30 SPACE ONLY a 14 Kitchen Rage SPACE ONLY 13 I SPACE 0N1..5 Is 8.72 15 6012 SPACE ONLY 15 D 16 I SPACE ONLY 17 SPACE ONLY SPACE ONLY c a 18 1 SPACE ONLY 19 Kitchen Range SPACE ONLY a 0 20 SPARE SPACE ONLY a 22 SPACE ONLY 21 I SPACE ONLY 23 23 SPACE ONLY SPACE ONLY c D 24 SPACE ONLY SPACE 0141.5 a 28 SPACE ONLY SPACE ONLY 25 70/3 SPACE ONLY 27 27 SPACE ONLY SPACE ONLY b b 28 1 SPACE ONLY 29 1 SPACE ONLY 29 a 30 SPACE ONLY LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY (COM) CONNECTED CALCULATED LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY COAT) CONNECTED CALCULATED LIGHTING 0.00 KVA 0.00 KVA (12596) HEATNG & MISC 1.50 KVA 1,50 KVA (100%) LARGEST MOTOR 0.80 KVA 0.00 KVA (12596) NONCONCDENTAL 0.00 KVA 0.00 KVA ( 0%) OTHER MOTORS 0.00 KVA 0.00 KVA (10094) KITCHEN EOPT 0.00 KVA 0.00 KVA (85 %) RECEPTACLES 1 38 KVA 1.38 KVA ( 5094 > 10KVA) CONTINUOUS 0.80 KVA 0.00 KVA (12596) TOTAL 2.88 KVA 288 KVA 1200 AMPS 12.00 AMPS Nan 1) Noma was tar so 4004 as rurnmrte40 on LOAD SUMMARY (SAM 122-3) PaASCN DATE 618808 PANEL "P" SCHEDULE DESIGNATION Panel P 240) 120 VOLTS 3 PHASE, 4 WIRE NOTES: Existing Panel "P. To Be LOCATION Apparatus Room 225 AMP MAN LUGS ONLY Demolished FED FROM MN 100% NEUTRAL 10000 AC SYM CE 0 OCT BKR CIRCUIT DESCRIPTION LOAD KVA P LOAD H KVA CN 0 CKT BKR CIRCUIT CESCRPTIDN 1 2013 Wet Bay Door Opener 1.68 a 1.68 2 2013 Easty Bay Door Opener 3 1 1 b 4 I 1 5 1 1 4.30 c 6 I 1 7 2012 Elec. Heater Front Dome 430 a 4.30 B 202 Elec. Feeler Freed Mae 9 1 I 4.30 5 c 4.30 10 1 1 -_, 12 202 Elec. Heater Resaoona 11 20/2 Elec. Heater Rea Dams 4.30 13 I I Kitchen Rage 4 14 I I Is 8.72 18 6012 Air Compress". 15 b SPACE ONLY I 17 17 SPACE ONLY SPACE ONLY c 18 I 1 19 5012 Kitchen Range 9.80 a 20 20/2 SPARE 21 I I b 22 I I 23 23 SPACE ONLY SPACE ONLY c 24 24 SPACE ONLY 25 25 SPACE ONLY SPACE ONLY a 26 70/3 SPARE 27 D SPACE ONLY b 28 I 1 c 30 1 ) 29 a SPACE ONLY SPACE ONLY LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY (COM) CONNECTED CALCULATED CORING 0.00 KVA 0.00 KVA (125%) HEATING 8 MISC 23.92 KVA 23.92 KVA (10016) LARGEST MOTOR 0.00 KVA 0.00 KVA (12516) NONCOOICCENTAL 0.68 KVA 0.00 KVA ( 0%) OTHER MOTORS 3.32 KVA 132 KVA (100%) KITCHEN EOPT 9.63 KVA 8.24 KVA (65%) RECEPTACLES 0.00 KVA 0.60 KVA (50%> 10KVA) CONTINUOUS 000 KVA 0.00 KVA (125 %) TOTAL 38.84 KVA 33.48 KVA 88.62 AMPS 80.54 AMPS 1/TE EXITING PAWL TO BE FEPLA®. SCHEEUFRCVDE0 FOR REERMEOILY. REV6ON CA1E 52020CD PANEL "P" SCHEDULE DESIGNATION Panel P 240 / 120 VOLTS 1 PHASE, 3 WIRE NOTES: Nov Panel'P LOCATION Apparatus Room 225 AMP MAN UUG5 ONLY FED FROM MDP F5862 1CO% NEUTRAL 10000 AID 0154 CIR 8 OCT BKR CIRCUIT DESCRIPTION LOAD KVA P LOAD H KVA CN 0 CKT BKR CIRCUIT DESCRIPTION 1 1512 West Bay Door Opener 1.88 a 168 2 15/2 Easty Bay Door Opener 3 1 I b 4 I 1 5 202 Elec. Heater Front Dame 4.30 a 4.30 8 2012 Elec. Heater Fran OM. 7 I I Is B I I 9 2012 Elec. Heater Re0 Dome 4.30 a 4.30 10 20/2 Elec. Heater Ret Man s 11 I I b 12 I I 13 5012 Kitchen Rage 9.80 a 8.72 14 6012 At Compressor 15 1 I b 18 I I 17 SPACE ONLY • 18 _ SPACE ILLY 5 20 SPACE ONLY Jai jp 19 SPACE ONLY a 22 SPACE ONLY n�$� ,L� 21 SPACE ONLY 23 SPACE ONLY b 24 SPACE ONLY 25 SPACE ONLY • 28 SPACE ONLY /r�� D 28 SPACE 0M-5 Olt 27 SPACE ONLY 29 SPACE ONLY a 30 SPACE ONLY LOAD SUMMARY. CONNECTED CALCULATED LOAD SUMMARY (CONT) CONNECTED CA LCl1L UGHTNG 0.00 KVA 000 KVA ( 25%) HEATING 8 MISC 23.92 KVA 21.92 KV (1 LARGEST MOTOR 0.00 KVA 0.0) KVA ( 25%) NONCO0ICDENTAL 0.60 KVA 0.80 KVA ( 0%) OTHER MOTORS 3.32 KVA 132 KVA ( 0016) KITCHEN EOPT 9.68 KVA 9.24 KVA ( 5516) RECEPTACLES 0.68 KVA 0.68 KVA (50% > 10KVA) CONTINUOUS 000 KVA 0.00 KVA ( 25%) TOTAL 38.84 KVA 33.48 KVA 153.50 AMPS 139.50 AMPS NOTE LGA06 BORN APE FOR TAN. SED0NLV. ACTUAL LOAD N},(KI® NmOAY 80038089000980E LOAD SLUMMY, Fe/60N DA TE YA'JDOe CEIVED T 1620 MIT CENTEF I9 1 SUBMISSION / REVISION DRAVN BY, R. HAZZARD DECKED BY, B. GIESE DESIGNED DT. K NOITRY APPROVED BY aGIESE DATE. JUNE MS PROJECT PD06P0051 FIRE STATN)N ONE -UNE D E2 -3 SHT. 8 OF 14 E2 -3 Fire Sfativa LiWkniagr .osrA3 .� ,am 2 Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.c4m - Always Verify.Scale 3 4 5 Cop o(gla o 2002 TIC, AB lights Resew& 1 D c B A O 2 3 1•C, FOR GENERATOR CONTROLS [S DISCONNECT NEA3R MA E3-1 E2 -2 CONTROLS C' 2D 50KW STANDBY GENERATOR CIRCUIT FROM CT CABINET TO EMERGENCY PANEL ATS PANEL A OUTSIDE LIGHTING CONTROL CABINET MOP FS f$3 I l TO PORTABLE GENERATOR EMERGENCY CT CABINET RECEPTACLE OUTSIDE PANEL -E STATION EAST WALL (VERIFY EXACT LOCATION) SECOND FLOOR MECHANICAL LOFT a SCALE 1 /Er - 1' -O• STANDBY FEEDER I II 2•C. 3/4/0, 112 EGC MOP -5.7 1 •C- 3/10,1 /10EGC METER BOX CT CABINET COMM CABINET OU AR TERS LD J RESOURCE POOM COMM CABINET E3-1 IE MEETING. AREA GENERATOR ANNUNCIATOR PANEL 1• C, FOR GENERATOR ANNUNCIATOR PANEL II L STORAGE +10 RESTROOM 109 WOVEN J CONCRETE PAD / A 1 E3-1 ES- OUAP TERS r 1 EXISTIN1; HVAC EOUIPMrNr I —REVIEWED RrF COMPLIANCE OOT 2 2 2013B City � PARTIAL FLOOR PLAN SCALE 1/4• . i• -o- �jt -1 -Jrc Tukwila C.JA RTERS E'NERG•SE ROOM 8 1 FLAG NOTES PROVIDE WP/GFa RECEPTACLE MOUNTED ON UNI -STRUT SUPPORTED FROM GENERATOR CONCRETE PAD. MOUNT RECEPTACLE +16• ABOVE CONCRETE PAD. TERMINATE GENERATOR EXHAUST STACK 10' FROM PROPERTY LINE AND 10' FROM BUILDING AS REQUIRED BY IMC SECTION 501.2.1 REMOVE CONDUCTORS AND NE PORTABLE GENERATOR RECEPTACLE ABANDONED CONDUIT SEAL ALL PENETRATIONS. COORDINATE WITH SCL TO FIND EXACT LOCATION OF UT1uTY TRANSFORMER. �� DETAIL •A• ON SHEET E3-2 FOR CONDUIT ROUTING it LAM, NOR L - U EMS LJ r VFNDN:, ECEr►' ®CT 16 2008 PERMIT CENTEh GRAPHIC SCALE : I �•,•� 0• 2' 4• rr 12• LEI g 58` 5 SUBMISSION / REVISION DRAVN Yi R. NAZZARD CHECKED 3Y. & GIESE D c DESIGNED IVY, K. NSSTRY APPROVED 1Y B. GIESE DATE JUNE BOOB PRAXES PIX16P00S1 FIRE STA110N iS3 PARTIAL PAS E3.1 SHT. 9 Of 14 E3 -1 Fire $ les't> g1. �,ir . .D„�D:aR,,•„". 2 Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always VerWSle. 3 4 5 CapyvdQlK O 0m7. TAG. M ROM Reserved. B A 1 D C B A 2 3 MAIN DISTRIBUTION PANEL SCHEDULE DESIGNATION MDP FS#53 240 1 120 VOLTS 1 PHASE. 3 WIRE NOTES: Existing Panel LOCATION NW Caner 400 AMP MAIN CIRCUIT BREAKER FED FROM ATS 10016 NEUTRAL 22000 AC SYM CR 6 CKT 8KR CIRCUIT DESCRIPTION LOAD KVA P H KVA CM it CKT BKR CIRCUIT DESCRIPTION 1 20/2 TVSS a 2 100/2 Panel E 9 4 I 3 1 J 5 2011 Generator eatery Charger 1.38 a 6 602 Emergency Canpesan 7 20/1 Generator Block Master 1.60 b 8 1 I 8 SPACE ONLY a 10 602 Hose Tower -Tek COmpesaor 11 SPACE ONLY 6 12 1 I a 14 SPACE ONLY 13 SPACE ONLY b 18 SPACE ONLY 15 SPACE ONLY 17 SPACE OMY a 18 SPACE OMY b 20 SPACE ONLY 19 SPACE ONLY 21 SPACE ONLY a 22 SPACE ONLY b 24 SPACE ONLY 23 SPACE ONLY 25 SPACE ONLY a 26 SPACE ONLY 0 28 SPACE 07621 27 SPACE OMY 29 SPACE ONLY a 30 SPACE 096_7 31 225/2 Panel El a 32 22512 Pad A I I 6 I I LOAD SUMMARY CONNECTED CALCULATED LOAD SUMMARY (CONI) CONNECTED CALC14 51EO UGHT54G 0.00 KVA 000 KVA (129%) !EATING & MISC 1 50 KVA 1.50 KVA (100%) LARGEST MOTOR 0.00 KVA 0.00 KVA (125%) NON-COINCIDENTAL 0.00 KVA 0.00 KVA ( 0%) OTHER MOTORS 0.00 KVA 0.00 KVA (100%) KRCIEN EQPT 0.00 KVA BOO KVA (85 %) RECEPTACLES 1.38 KVA 1.3B )0/5 (5016 > 10(515) CONTINUOUS 0.1:0 KVA 0.00 KVA (125%) TOTAL 288 KVA 2.86 KVA 12.00 AMPS 12.00 AMPS Man 1) 8818:1)66855 lamb for Ms peal se summered an LOADSTASURY Bc8 Mimes raw bads In the psaL SCL CT CABINET E::::.3- C- 3 /500KCMIL r L TO SCL VAULT SCL TRANSFORMER j 75 KVA SECONDARY: 120/24DV,1 e,3W 3'C 3/500 KCMIL SCL METER BOX L 4 _1© (25/2 PANEL MOP FS /53 120/240'1,10,3W MDP FS /53 400/2 r 1 20/2 40V,1 0,3W 400 AMPS T 22K&IC (100/2 (225/2 J )25A MAIN LUGS ONLY GENERATOR TRANSFER PANEL /G- PORTABLE 4 GENERATOR DEMOLITION PARTIAL ONE —LINE DIAGRAM SCALE NONE R1NL40NDATE 5/2020M GENERATOR CIRCUIT BREAKER 1 4730 STANDBY GENERATOR r SOKW,120/ 40NV.10.3W ,(I - S 1 161711 200A MN CIRCUIT BREAKER J LOAD SUMMARY PANG: MAIN DISTRIBUTION PANEL (EDP F5053) EASING LOAD RECORDED 30-DAY PEAK DEMAND ON 1,44.2007 21.00 KVA SEASONAL ADJUSTMENT FACTOR (1.08) 168 KVA SEASONALLY ADJUSTED PEAK DEMAND 22 68 KVA 125% OF CURRENT MAX ( NEC 220 07) 567 KVA ADJUSTED PEAK DEMAND 28 35 KVA ADDED LOAD TO DE 1.B X88 KVA use ADCC.... AD sb I TOTAL CALCULATE) PEN( DEMAND AMPERES © 240 VOLTS, 1 PHASE 31.23 KVA 13013 Amps TO SCL VA AT SCL TRANSFORMER - - 75 F7A ▪ ' SECONDARY: 120 /240V, I0,3W ra' SERVICE ENTRANCE RATED DISCONNECT 2 POLE 2 C- 3/4/0,1/2 E ICI L!J NJ ATS 400A 2 POLE 6730 L 9041 - RE -USE EXISTING CONDUIT Q SCL METER CABINET r F.-�, SCL METER BOX 4 M Y 3 -C -3000 KCMIL (2)2 0-3/4/0.1 /2 EGC ROUTE USING DOST1NG CONDUIT. (225/2 PANEL 8 MDP FSp53 400/2 - 12O'240V,10,3W 400 AMFS T, 2 I AIC (100/2 (225/2 J 125A MAX. LU'4S GENERATOR TRANSFER PANEL REVISED PARTIAL ONE —LINE DIAGRAM SCALE NONE SERVICE ENTRANT RATED DISCONNE FLAG NOTES: DISCONNECT SERVICE ENTRANCE CONDUCTORS AT MOP. RE -SIZE SERVICE ENTRANCE CONDUCTORS SO THE LENGTH IS SUFFICIENT TO CONNECT TO 400 AMP SERVICE ENTRANCE DISCONNECT. PROVIDE 3-C FROM SCI CT CABINET TO SERVICE ENTRANCE RATED DISCONNECT AS SHOWN ON DRAWING 53-2. USE EXISTING WIRE FROM CT CABINET TO SERVICE ENTRACE DISCONNECT. !� ROUTE CONDUCTORS FROM MS TO MDP FS/53 THROUGH SCL CT CABINET. USE EXISTING CONDUIT FROM CT CABINET TO PANEL MDP FS#53. COORDINATE WITH SCL BEFORE USING SCL METER CABINET TO ROUTE CONDUCTORS. 30 DAY METERING POINT. I] PROVIDE (2) 3/4- DIAMETER. 10' -0 LONG, COPPER CLAD STEET. GROUND ROD FOR GENERATOR ECIIPMENT GROUND. USE EXOTHERMIC WELDS. REMOVE CONDUCTORS AND 111E PORTABLE GENERATOR RECEPTACLE ABANDON CONDUIT. SEAL ALL PENETRATIONS PROVIDE SOUR NEUTRAL CONNECTION BETWEEN GENERATOR NEUTRAL AND UTIUTY TRANSFORMER NEUTRAL 1- C TO ANN i4CIATOR PANEL REVIEWED FOR C®®E Cc �p E p FPw NEC E OCT 2 2 2008 Oity0f Tavola g ILDYNG DWISION (2)2' 400 AMP 2 POLE NDAA 3R ENCLOSURE ATS 400A 2 POLE NE3AA 3R ENCLOSURE SCL 3, METE BOX J SCL CT CABINET 2-C FOR FEEDER CONDUCTORS 1 -C LDW r VOLTAGE CONTR ANTICIPATED CONDU ROUTING TO GENERATOR REVISED ELEVATION SCALE 1/2' - E-2 EXIST CONDUIT TO MDP FS/53 LOCATED IN MECHANICAL LOFT EXIST CONDUIT FROM UTIU TY COMM CABINET RECEIVED OCT 162008 PERMIT CENTEF a E. SUBMISSION / REVISION DRAWN I1'. R NAZZARD CHECKED I`!. & OffSE D C DESIGNED BT. K NISIRY APPROVED IT & IIIESE DATE. .JANE 21306 PROJECT PBOSPU,ST FIRE STATION ONE -UNE D WAD SUMMARY ELEVATION DETAILS E3 -2 SHT. 10 OF 14 E3 -2 Fire 2 Statilsila�rAialgrar >�s1�AadSuEl�q�.Edevation Details Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always Verify Scale 3 5 Comdata 02007. TAC. AI ZION R6,a,ati 1 D c B • 3 — 11,1 AI INCOMING UTILITY SERVICE CONNECTION AND METER CABINET E4-1 E4-2 "b `• r`.. d. •.. 20OA,IP DISCONNECT Eht Eh FOR PANEL A 2O0A,1P DISCONNECT FOR PANEL B I , , PANEL B PANEL E DEMOLITION /\4 ir �- PARTIAL PLAN ',.>' �. SCALE: 1/8- - 1' -0' � i x VJ 0\4,13014:C „ FLAG NOTES: \co*pi10 0I" �4`R 2 2 2009 'CV rt`59,t) ��� 0)._ �y �`1�_� fr..... +MOUNT \ Q 1� PROVIDE YYP /GFq RECEPTACLE MWNTED ON UNI -STRUT SUPPORTED FROM GENERATOR PAD. RECEPTACLE AT +18' ABOVE STUB -ETE PAD. STUB -VP CONDUIT TO NEMA 3R J-BOx SE RATED DISCONNECT INCOMING UTIUTY SERVICE CONNECTION AND METER CABINET E4-1 E4-2 L 1 I- 11- �a r B_r7.,_ —_ —_ _ TO MDP -5,7 Q _�_�- 1'C- 2j10,1#10 EGC INTERCEPT AND REUSE DUSTING CONDUIT b o « rc 5 1 ••. " E4-1 E 3 ( ) © Lt, PANEL ANEL B MAIN DISTRIBUTION PANEL (MDP F5�54) Eli 4O0A ATS, 2 POLE Q BATTERY CHARGER � HEATER GENERATOR E4-1 E 2 GENERATOR BLOCK ANNUNCIATOR ATS CONTROLS PANEL FEEDER tA STANDBY -- GENERATOR STANDBY CONCRETE PAD A Eht ES-1 �• �'� , � ����� R E C - L _ -_ - - -. PANEL B PANEL E (V 41 u L 1{it OCT I, a 6 2008 - \ — — • DRAWN BY R. NA22AR0 CHECKED BY B. GIESE DESIGNED K. KISTRY APPROVED S. GIESE Y -- __- DATE, ma PRC..ECT PD06POOSI - -��- .. LL _ - -.. PERMIT CENT REVISED "' PARTIAL P! E4 -1 SHT. 11 OF 14 PARTIAL PLAN 0� GRAPHIC SCALE ` 1 '1'� —� —� SCALE ,/8' 1' -0' • 4' 8' 18' 24' E4 -1 Fire 4�sI1 Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com- = Always Verify Scale 2 5 D c B A 1 FLAG NOTES: COORDINATE LOCKER DEMOLJTION WITH OWNER. PERMISSION WAS GRANTED TO DEMO LOCKER TO MAKE SPACE FOR ELECTRICAL EQUIPMENT. 2 3 1 OPEN LOCKERS 41 REMOVE AND RELOCATE AS DIRECTED BY OWNER DEMOLITION ELEVATION SCALE: 1- - 1• -O' TO ELECTRICAL CABINET E4-1 E4-2 A CONDUIT TO PANEL A 200 A FUSED DISCONNECT FOR PANEL A / WATER HOSE CORNER WALL 200 A FUSED DISCONNECT FOR PANEL B CONDUIT TO PANEL B CONDUITS INTO BUILDING 7- CORNER WALL CONDUIT FROM UTILITY POLE U TIU TY CABINET UTIU TY METER REVIEWED FOR CODE COMPLIANCE 1 NFPA 70 - NEC L,;T 2. z 2008 �Dnrt C la DEMOLITION ELEVATION SCALE`_ 1' - ,• -0- who 8R€ Ext ylo A15 400 AMP 2 -POLE EXISTING 2 CONDUIT TO PANEL A (2)2 -C- 3@4/0,112 EGC 1'C GENERATOR ANNUNCIATOR PANEL 114301-11°,12-L x 4'D CORNER WALL �2 -C- 3/4/0.112 EGC 2-C-3#4/0.1/2 EGC EXISTING 2•C CONDUIT TO PANEL 9 MDP FS#S4 400 AMP 10,3W 12"H x X2'L x 4-D TO GENERATOR REVISED ELEVATION SCALE 1' - 1• -0' TO GENERATOR BLOCK HEATER S AND CONTROLS CORNER WALL /—CONDUIT FROM UnuTY POLE UTILTY CABINET 3 1 /2'C- 3/350KCMIL1/1 /0 EGG NEW CONDUIT. RE -USE EXISTING CONDUCTORS UTILITY METER 400 AMP 2 POLE NEMA 3R ENCLOSURE SE DISCONNECT RECEIVED OCT 0 6 2008 REVISED ELEVATION SCALE 1' - I• -0- PERMIT CENTER DESCRIPTION SUBMISSION / REVISION DRAVR D R NAZZARD DECKED BY H. GIESE DESIGNED DY, K. IOSTRY APPRDVED DY JL GIESE DATE, JUNE 200@ PRO.ECT PDOSP0031 FIRE STATION fs4 DETAILS E4.2 SHT. 12 OF 14 E4-2 Fire AOp, gEWAS,,.4 -�m ,m,m�, ,an 2 Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www.bxwa.com - Always Venfv Scaie 3 4 5 Capplg4 0 400, TAG, An RW,e R9se oi. • 1 D C A SCL CABINET 3 /500KCMIL. 1 /1 /0 ECG r 200A SAFETY DISCONNECT SWITCH TO SCL VAULT r 7 SCL TRANSFORMER 750 %/A, L J 120/240V,10,3W SCL METER BOX r - �- 2 ELECTRICAL CABINET 200A SAFETY DISCONNECT SW TCH 60A RECEPTACLE DEMOLITION PARTIAL ONE -LINE DIAGRAM SCALE NONE SCL CABINET TO SCL VAULT 3 SCI. TRANSFORMER 75KVA J 120/240V.10.3W METER BOX SERVICE ENTRANCE RATED DISCONNECT 2 POLE (2) 2'C- 3/4/0.1/2 EGC GENERATOR BREAKER 2 POLE r�� - - - --1 I1 °I 7---11 47791 22 *C 3/4/01#2 EGC (2) 2*C- 3/4/0.1/2 EGC 2 ATS 400A 2 POLE 1 7035 r (400/2 1/ (200/2 I STANDBY GENERATOR 50KW,120/240V,10.3W 200A MAINUNE CIRCUIT BREAKER MDP FS#54 MTH 400A MAIN BREAKER 120/240V.10.3W 3/4/0.1 /2 EGC �1 REVISED PARTIAL ONE -LINE DIAGRAM SCALE: NONE FLAG NOTES: INTERCEPT AND REUSE E30511NG CONDUIT TO PANELS A AND B. PULL NEW CONDUCTORS FOR PANEL FEEDERS SOLID NEUTRAL CONNECTION BETWEEN GENERATOR NEUTRAL AND UTIUTY TRANSFORMER NEUTRAL 30 DAY METER POINT. PROVIDE (2) GROUND R00 3/4' DIAMETER. COPPER CLAD STEEL, MINIMUM LENGTH 10. FOR GENERATOR EQUIPMENT GROUND. USE EXOTHERMIC WELDS REMOVE CONDUCTORS AND THE PORTABLE GENERATOR RECEPTACLE ABANDONED CONDUIT SEAL ALL PENETRATIONS PROVIDE CONDUIT, RE -USE CONDUCTORS. MAIN DISTRIBUTION PANEL SCHEDULE DESIGNATION MDP FS#54 2401 120 201.111 1 PIKSE. 3 WIRE NOTES: New Panel LOCATION NW Cans 400 AMP MAN CIRCUIT BREAKER FED FROM MS 100% NEUTRAL 10000 AC SYM CN 0 CAT BKR CIRCLET DESCRIPTION LOAD KVA P LOAD H KVA C8R 0 CKT SKR CIRCUIT CESCRITION 1 200/2 Pa%t A a 2 200'2 Panel B 5 4 1 3 I 5 20/1 Receptacle at Generator 1 38 a 8 SPACE ONLY 7 20/1 Generator Block Home 1.50 b 8 SPACE ONLY a 10 SPACE ONLY 9 SPACE ONLY b 12 SPACE ONLY 11 SPACE ONLY 13 SPACE ONLY • 14 SPACE ONLY D 18 SPACE ONLY 15 SPACE ONLY • 18 SPACE ONLY 17 SPACE ONLY 19 SPACE ONLY D 20 SPACE OILY 21 SPACE ONLY a 122 SPACE ONLY b 24 SPACE ONLY 23 SPACE ONLY a 28 SPACE ONLY 25 SPACE ONLY 27 SPACE ONLY 5 28 SPACE ONLY 29 SPACE ONLY a 30 SPACE ONLY LOAD SUMMARY: CONNECTED CALCULATED LOAD SUMMARY (CONT) CONNECTED CALCULATED LIGHTING 0.00 KVA 0.00 KVA (125%) NEATNG 8 RISC 1.50 KVA 1.50 KVA (100%) LARGEST MOTOR 0.00 KVA 0.00 KVA (125%) NOWCONCIOENTAL 0.00 KVA 0.20 KVA ( 0%) OTHER MOTORS 0.00 KVA 0.00 KVA (100%) 8501-E■ EOPT 000 KVA 0.00 KVA (G5%) RECEPTACLES 1.38 KVA 1.38 KVA (50%, 10KVA) CONTINUOUS 0.00 KVA 0.00 KVA (125 %) TOTAL 2.88 KVA 288 KVA 12.00 AMPS 1200 AMPS Nwn' 1) L4mbale Peer • sunaR• m LLAD6BAMRf (Swot E S) LOAD SUMMARY PANEL: MAIN DISTRIBUTION PANEL (LDP F0654) E)STNG LOAD: RECORDED 30.0AY PEAK DEMAND ON 11/8/2007 18.00 KVA SEASONAL ADJUSTMENT FACTOR (1.11) 1.76 KVA SEASONALLY ADJUSTED PEAK DEMAND 17.78 KVA 129% OF CURRENT MAX( NEC 220.87) 4.44 KVA ADAISTED PEAK DEMAND 22.20 KVA ADDED LOAD TO THE BULDNG X88 KVA IeEE NYE1.1.1101.6 % ro .060 aw sac �I TOTAL CALCULATED PEAK DEMAND 25.08 KVA AMPERES ® 240 VOLTS. 1 PHASE 104.50 AMPS 65/1== DATE 52oacce CONTINUOUS DRIVING SURFACE WARNING RED TAPE L1'►.= u►2 W 1 =1 1 = I1 I1 -_ 1 24' MIN. 30' MAX _1 UNDER DRIVING _ 1= SURFACES GRS (TYP) 0 0 8' a 1- 1i! -111 -11 1- III =1"- I' CDF BAgffILL NOM 1. 2. SEE PLAN RESTORE SURFACE BACK SIZE ORIGINAL 8 \ 'lmm %9 E 4 ` F DIRECT BURRY DETAIL, DETAIL SCAT F. NONE OCT 1620"; PERMINTEF E4-1 E4-3 (pi! 2 2 i MISSION / REVISION O ORAVN Y, R. NAZZAR0 OECKED BY, a GIESE DESIGNED BY K. NISTRY APPROVED BY a GIESE DATE, JAE 2008 PROJECT PD06P0051 FIRE STATION /54 , ONE -UNE IAG�AIIS asaroo E4 -3 SHT. 13 OF 14 I 2 Fire Swft,,„Qm145,cA Brari1SPI ggpgtail Provided to Builders Exchange of WA, Inc. For usage Conditions Agreement see www_bxwa.com_ Always Verify Scale. 3 1 4 5 Coya10N O 6537, TAC. AI ROM Rem0a0. • 5 -6' t` 50 KV GENERATOR PAD 6'-O• • V 0 20' TFN PAD • B (10) 14 TOP/BOT (7) 14 TOP/BOT 230 KV GENERATOR PAD 2'-0' THK PAD • D (16) 15 TOP/BOT (7) 15 TCP/BOT r SECTION A r - 0• 7 REINF PER PLAN GROUND LEVEL 2 ' / < ' \ — I MAX (7)µV /EXtSL GRADE (2) # e■ PER PLAN SECTION B CENTER GENERATOR ON PAD GROUND LEVEL REINF PER PLAN — REVIEWED FOR COMPLIANC E C NFpA7O - NEC Cv 22 233% • City Tuicwil IAN B LD1MG 0 lV STRUCTURAL BACKFILL SECTION C CENTER GENERATOR'. ON PAD PER PLAN SECTION D GROUND LEVEL REINF PER PLAN RECEYVEt OCT 16 2008 PERMIT CENTEF 1 5 2 DRAWN BY: LIDA CEDED BY: JAIH ECM= BY JGC APPROVED BY: EJS DAIS JUNE 2008 r0DJCDT PD08P0051 1 2 E5 -1 Generator Pad Details Provided to Builders Exchange of WA,. Inc, For usage Conditions Agrgelnent se_e_www_bxwa_com - Alway verify Scale 3 4 5 Gopp2A10 207, TAC, Ae 80 R0 »2d.