HomeMy WebLinkAboutPermit EL08-1375 - UNIVERSITY OF WASHINGTONUNIVERSITY OF WA 12201 TUKWILA INTERNATIONAL BL EL08- 1375 Parcel No.: Address: Suite No: Cit34f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us ELECTRICAL PERMIT 0923049120 12201 TUKWILA INTERNATIONAL BL TUKW Permit Number: EL08 -1375 Issue Date: 10/28/2008 Permit Expires On: 04/26/2009 Tenant: Name: Address: Owner: Name: Address: UNIVERSITY OF WASHINGTON 12201 TUKWILA INTERNATIONAL BL, STE 300 , TUKWILA WA INTERNATIONAL GATEWAY WEST 12201 TUKWILA INTERNATIONAL BLVD , SEATTLE WA Contact Person: Name: LAURA RANNOW Address: 5614 7 AV S , SEATTLE WA Contractor: Name: VECA ELECTRIC CO INC Address: 5614 7 AV S , SEATTLE WA Contractor License No: VECAECI542MU Phone: Phone: 206 436 -5245 Phone: 206 860 -0231 Expiration Date: 10/31/2009 DESCRIPTION OF WORK: INSTALL POWER FOR A (8) FAN DRY COOLER ON THE ROOF. INSTALL POWER FOR A LIEBERT CRAC UNIT. INSTALL POWER FOR (2) PUMPS IN THE PUMP ROOM (ONE REPLACING EXISTING, ONE NEW). POWER FOR (2) PREVIOUSLY INSTALLED PDU'S IN THE SERVER ROOM (A3 AND B3). POWER WILL COME FROM EXISTING UPS MODULES. VECA #84443 -813 Value of Electrical: $48,000.00 Fees Collected: Type of Fire Protection: National Electrical Code Edition: Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied $1,086.50 2005 Date: :o(Z b1, Dt, ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this p - rmit oes not pres construction or ,- rfo a- ce of wor Signature: Print Name: give authority to violate or cancel the provisions of any other state or local laws regulating uthorized to sign and obtain this electrical permit. 4;/4 y Date: (% `1/off This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1375 Printed: 10 -28 -2008 Parcel No.: 0923049120 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 12201 TUKWILA INTERNATIONAL BL TUKW UNIVERSITY OF WASHINGTON Permit Number: Status: Applied Date: Issue Date: EL08 -1375 ISSUED 10/21/2008 10/28/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe t does not presume to give authority to violate or cancel the provision of any other work or local laws regulating c ; tru• 'on or thepgrf ance of work. Signature: � / Print Name: / I P 1 °' " Y' 166 i) Date: doc: Cond -Elec EL08 -1375 Printed: 10 -28 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vvww.ci.tukwila.wa.us Electrical Permit No. Ewe Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 12201 Tukwila International Blvd King Co Assessor's Tax No.: 0 60144 — Suite Number: #300 Tenant Name: University of Washington Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila International Blvd 4th Floor, Tukwila, WA 98168 New Tenant: Floor: ❑ Yes XI..No City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Laura Rannow Day Telephone: 206-436-5245 Mailing Address: 5614 7th Ave S Seattle, WA 98108 City State Fax Number: 425 - 696 -0128 E -Mail Address: laura.rannowBveca.com Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA Electric Co, INC Mailing Address: 5614 7th Ave S Seattle, WA 98108 Contact Person: Laura Rannow E -Mail Address: laura.rannow @veca.com Contractor Registration Number: VECAECI542MU City State Day Telephone: 206- 436 -5245 Fax Number: 425- 696 -0128 Expiration Date: 10/31/09 Zip Valuation of Project (contractor's bid price): $ 48,000.00 Scope of Work (please provide detailed information): Install power for a 8 fan dry cooler on the roof. Install power for a Liebert CRAC unit. Install power for two pumps in the pump room (one replacing existing, one new). Power for two previously installed PDU's in the server room (A3 & B3). Power will come from existing UPS modules. VECA #84443 -813 Will service be altered? ❑ Yes IX No Adding more than 50 amps? ❑ Yes IX No Type of Use: Data Center Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: ❑ Puget Sound Energy �X Seattle City Light ❑ Service Change ❑ Fire Alarm H:\Applmanons \Forms - Applications On Line \4 -2007 - Electrical Permit Application doc bh ❑ Remodel [I Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Camivals $75.00 Number of concessions $10.00 ca PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signaturd aokis/L.G. CJ./V"VIarLA. M Print Name: boar ce_pt ?.P1/4N u c VV Mailing Address: S-131 (44U S IDate Application Accepted: 90121 li,7b Date: is l zl 16,8 Day Telephone: ^ 436 - saMs- Seati le_ _.vr4 ( q8106 City State Zip 0(11741M) Date Application Expires: Staff Initials: / H:\Applications \Forms- Applications On Line \4 -2007 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 0923049120 Permit Number: EL08 -1375 Address: 12201 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 10/21/2008 Applicant: UNIVERSITY OF WASHINGTON Issue Date: Receipt No.: R08 -03584 Initials: JEM User ID: 1165 Payment Amount: $1,086.50 Payment Date: 10/21/2008 03:44 PM Balance: $0.00 Payee: VECA ELECTRIC CO INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1259 1,086.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 869.20 000.345.832.00.0 217.30 Total: $1,086.50 doc: Receiot -06 Printed: 10 -21 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3470 Log -131 Project: j ( ^r !- , � j . JPtia Type of Inspection: -., \ Address: 1221 T. t. 3. Date Called: Special Instructions: Date Wanted: Z O a.m,� fi' Requester: l Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: FILE COPY cmRgFITI°wiu OCT 212008 PERMIT CENTER VECA Electric SWBD MAIN SWITCHBOARD ROOM: LEVEL 3 ELECTRICAL ROOM LOAD DISTRIBUTION FROM: BUILDING MAIN ELEC ROOM RCPT LTG EOP HEAT DESCRIPTION AMP P LOAD kVA AMPS HP 225 3 - - Hi 400 3 - - AMP: 2500 H2 400 3 - - VOLTS: 277 H3 400 3 - - 480 H4 400 3 - - PHASE: 3 30.0 24.0 742.1 0.0 MDP ON LEVEL 3 1200 3 796.1 957.5 WIRE: 4 SUB -MAIN 800 3 - - BUS TYPE: AL ELEV #1 125 3 - - A.I.C.: 25K ELEV #2 125 3 - - M.L.O.: YES RTU#1 125 3 - - MAIN CB: RTU#4 125 3 - - MAIN FUSE: - - FLUSH: - - SURFACE: YES - - GND. BAR: YES - ISO GND: - - 200% NEU: - - FEED THRU: - - DBL LUG: - - TOP FEED: - - BTM FEED: YES - PANEL T.C.L - LOAD (kVA) - - RCPT 30.0 - LTG 664.7 - - EOP 742.1 - - HEAT - - - TOTAL 1,436.8 - FEEDER T.C.L - LOAD (kVA) - - RCPT 30.0 - - LTG 664.7 - - EOP 742.1 - HEAT - - - TOTAL 1,438.8 640.7 PEAK KW READING X 125% 640.7 770.6 - - FEEDER DEMAND - - kVA 1,592.9 TOTAL 1,436.8 1,728.1 AMPERES 1,918.0 30.0 664.7 742.1 - MFG: CB: NOTE: SIX DISCONNECT RULE. Protect: ICG B3- 10/21/08 10/21/08 Feeder T.0 l is pitied her horizontally to avow s WO "pfst►b tk to the load Dlea0obon' columns of a sub- feed panel or w ttohboard. 30.0 1 664.7 1 742.1 1 - FILE COPY cmRgFITI°wiu OCT 212008 PERMIT CENTER VECA Electric SWBD MDP ROOM: LEVEL 3 ELECTRICAL ROOM LOAD DISTRIBUTION FROM: BUILDING MAIN ELEC ROOM RCPT LTG EQP HEAT DESCRIPTION AMP P LOAD kVA AMPS 21.0 8.0 732.1 0.0 ATS-1 1200 3 761.1 915.4 9.0 18.0 10.0 SBS 800 3 35.0 42.1 AMP: 1200 ATS -2 (FUTURE) 800 3 - - VOLTS: 277 SPARE 1200 3 - - 480 3 - - PHASE: 3 3 - - WIRE: 4 3 - - BUS TYPE: AL 3 - A.I.C.: 85K 3 - - M.L.O.: 3 - - MAIN CB: YES 3 - - MAIN FUSE: 3 - - FLUSH: 3 - - SURFACE: YES 3 - - - - GND. BAR: YES - - ISO GND: - - 200% NEU: - FEED THRU: - - DBL LUG: - - TOP FEED: BTM FEED: YES - - PANEL T.C.L - - LOAD (kVA) - - RCPT 30.0 - - LTG 24.0 - - EQP 742.1 - - HEAT - - - TOTAL 796.1 - - FEEDER T.C.L - - LOAD (kVA) - RCPT 30.0 - - LTG 24.0 - EQP 742.1 - - HEAT - - TOTAL 796.1 - - FEEDER DEMAND - kVA 792.1 TOTAL 796.1 957.5 AMPERES 952.7 30.0 24.0 742.1 - MFG: CB: NOTE: Project: ICG B3 - 7/14/06 10/21/08 Feeder T.C.L 3 printed here horizontally to show s block'pasteMnK to the Yoed Distribution" columns of a sub- teed panel or switchboard. 30.0 I 24.0 I 742.1 I - y VECA Electric SWBD EHM2 ROOM: �. LEVEL 3 ELECTRICAL ROOM LOAD DI' ' IBITIAN^".— RCPT LT EQP HEAT CIR. - DE±B1834O AMP _ P LOAD kVA AMPS 3.7 1 CIRCULATION PUMP 20 3 3 7 4.5 3.7 3 20 3 3.7 4.5 AMP: 600 3.7 6 20 3 3.7 4.5 VOLTS: 277 7 CRAC .: ?) 40 3 - - 480 -- 9 40 3 - - PHASE: 3 11 A 40 3 - - WIRE: 4 3.0 13 DRY COOLER FOR CAC-8 1 20 3 3.0 3.8 BUS TYPE: AL 3.0 15 20 3 3.0 3.6 A.I.C.: 85K 17 20 3 3.0 3.8 M.L.O.: YES - MAIN CB: 21 SPACE - - MAIN FUSE: 23 SPACE - - FLUSH: 25 SPACE - - SURFACE: YES 27 SPACE - - 29 SPACE - - GND. BAR: YES 31 CAC -8 90 3 - - ISO GND: 33 90 3 - - 200% NEU: 35 " 90 3 - - FEED THRU: 37 CAC FUTURE 90 3 - - DBL LUG: 39 " " 90 3 - - TOP FEED: 41 90 3 - - BTM FEED: YES 2 DC1 15 3 - - 4 15 3 - - PANEL T.C.L 6 15 3 - - LOAD (kVA) 8 DC -2 15 3 - - RCPT - 10 " 15 3 - - LTG - 12 " 15 3 - - EQP 20.1 14 DC-3 15 3 - - HEAT - 16 " 15 3 - - 18 15 3 - - TOTAL 20.1 20 DC -4 15 3 - - 22 15 3 - - FEEDER T.C.L 24 15 3 - - LOAD (kVA) 28 SPACE - - RCPT - 28 - - LTG - 30 - - EQP 20.1 32 CAC FUTURE 90 3 - - HEAT - 34 90 3 - - 36 " 90 3 - - TOTAL 20.1 38 CAC FUTURE 90 3 - - 40 90 3 - - FEEDER DEMAND 42 " 90 3 - - kVA 20.1 TOTAL 20.1 24.2 AMPERES 24.2 - - 20.1 - MFG: CB: NOTE: Project: ICG B3 - 10/21/08 10/21/08 Feeder T.C.L. Is minted here horizontals to allow a block'paste-0nk' to the load DaOlhutioo" columns of a sub- teed panel or nyllehboard. - I - I 20.1 I - VECA Electric SWBD EMSB1 ROOM: LEVEL 3 ELECTRICAL ROOM VIA ATS -1 LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT , CIR. DESCRIPTION AMP P LOAD kVA AMPS 0.0 0.0 474.1 0.0 1 EMSB2 800 3 474.1 570.2 12.0 4.0 3 ELS1 250 3 16.0 19.2 AMP: 1200 5 TVSS 30 3 - - VOLTS: 277 7 EHS2 400 3 - - 480 11 -0 9 EHM2 600 3 11.0 13.2 PHASE: 3 11 GP VIA 30 KVA 50 3 - - WIRE: 4 9.0 8.0 11.0 13 EHS1 - OFF 400 3 28.0 33.7 BUS TYPE: AL 232.0 15 EHM1 600 3 232.0 279.1 A.I.C.: 65K 17 SPARE 400 3 - - M.L.O.: YES 19 3 - - MAIN CB: 21 3 - - MAIN FUSE: 23 3 - - FLUSH: 25 3 - - SURFACE: YES 27 3 - - 29 - - GND. BAR: YES 31 - - ISO GND: 33 - - 200% NEU: 35 - - FEED THRU: 37 - - DBL LUG: 39 - - TOP FEED: 41 - - BTM FEED: YES 2 - - 4 - - PANEL T.C.L 6 - - LOAD (kVA) 8 - - RCPT 21.0 10 - - LTG 8.0 12 - - EDP 732.1 14 - - HEAT - 16 - - 18 - - TOTAL 761.1 20 - - 22 - - FEEDER T.C.L 24 - - LOAD (kVA) 28 - - RCPT 21.0 28 - - LTG 8.0 30 - - EQP 732.1 32 - - HEAT - 34 - - 36 - - TOTAL 781.1 38 - - 40 - - FEEDER DEMAND 42 - - kVA 757.8 TOTAL 761.1 915.4 AMPERES 911.2 21.0 8.0 732.1 - MFG: CB: NOTE: Protect: ICG B3 - 11/9/06 10/21/08 Feeder T.C.L a primed Mm nonzontely to slow a blocc'pe$te-0mf to the 'Load D rterbon' columns or • sub- feed sand or switchboard. 21.0 1 8.0 I 732.1 I - VECA Electric swim EMS B2 ROOM: LEVEL 3 ELECTRICAL ROOM EMSB1 LOAD DISTRIBUTION FROM: RCPT LTG EQP HEAT CIR. _ DESCRIPTION AMP P LOAD kVA AMPS 221.6 1 UPS -A (400 KW /500 KVAI 800 3 221.6 268.5 3 MBC-A 800 3 - - AMP: 800 252.5 5 UPS-B (400 KW /500 KVA) 800 3 252.5 303.7 VOLTS: 277 7 MBC -B 800 3 - - 480 9 3 - - PHASE: 3 11 3 - - WIRE: 4 13 3 - - BUS TYPE: AL 15 3 - • A.I.C.: 65K 17 3 - - M.L.O.: YES 19 3 - - MAIN CB: 21 3 - - MAIN FUSE: 23 3 - - FLUSH: 25 3 - - SURFACE: YES 27 3 - - 29 - - GND. BAR: YES 31 - - ISO GND: 33 - - 200% NEU: 35 - - FEED THRU: 37 - - DBL LUG: 39 - - TOP FEED: 41 - - BTM FEED: YES 2 - - 4 - - PANEL T.C.L 6 - - LOAD (kVA) 8 - RCPT - 10 - - LTG - 12 - - EOP 474.1 14 - HEAT - 16 - • 18 - - TOTAL 474.1 20 - - 22 - - FEEDER T.C.L 24 - - LOAD (kVA) 26 - - RCPT - 28 - - LTG - 30 - - EQP 474.1 32 - - HEAT - 34 - - 38 - - TOTAL 474.1 38 - - 40 - - FEEDER DEMAND 42 - - kVA 474.1 TOTAL 474.1 570.2 AMPERES 670.2 - - 474.1 - MFG: CB: NOTE: Project: ICG B3 - 7/14/08 10/21/08 Feeder T.C.L a putted Awe rortzonteey to Mow a block - pooteEnlf to the -Load Dertributlon' column of a sub- teed panty 0r awltdr0omd. - I • I 474.1 I - VECA Electric swab MBC -A ROOM: UPS ROOM UPS-A LOAD DISTRIBUTION FROM: RCPT LTG EOP HEAT DESCRIPTION AMP P LOAD kVA AMPS 92.5 PDU -A1 250 3 92.5 111.3 129.0 .�2��. 250 3 129.0 155.2 AMP: 800 PDU-A3 260 3 VOLTS: 277 ISOLATION BYPASS 800 3 - - 480 � II BYPA 800 3 PHASE: 3 3 - - WIRE: 4 3 - - BUS TYPE: AL 3 - - A.I.C.: 36K 3 - - M.L.O.: YES 3 - - MAIN CB: 3 - - MAIN FUSE: 3 - - FLUSH: 3 - - SURFACE: YES 3 - - - GND. BAR: YES - - ISO GND: - - 200% NEU: - FEED THRU: - - DBL LUG: - TOP FEED: - - BTM FEED: YES - - PANEL T.C.L - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 221.6 - - HEAT - - - TOTAL 221.6 - - FEEDER T.C.L - - LOAD (kVA) - - RCPT - - - LTG - - - EQP 221.6 - - HEAT - - - TOTAL 221.6 - - FEEDER DEMAND - - kVA 221.6 TOTAL _ 221.6 266.5 AMPERES 266.5 - - 221.6 - MFG: CB: NOTE: CABINET LOADS ARE DUAL FED FROM PDU-A AND PDU -B. DESIGN LOAD WILL BE HALF OF THE UPS AND PDU CAPACITY. Project: ICG 83 - 10/21/08 10/21/08 Feeder T.C.L. b panted hmehorlooma y m eoow a dock -prsteimK to the load Distribution" columns of a nub- teed panel or switchboard - I - I 221.61 - VECA Electric SWBD MBC -B ROOM: UPS ROOM LOAD DISTRIBUTION FROM: UPS-8 RCPT LTG EQP HEAT DESCRIPTION AMP P LOAD kVA AMPS 92.2 PDU -B1 250 3 92.2 110.9 160.3 • - _ 250 3 160.3 192.8 AMP: 800 PDU-B3 260 3 - - VOLTS: 277 SO : •• : P: 800 3 - - 480 MAINT BYPASS 800 3 - - PHASE: 3 3 - - WIRE: 4 3 - - BUS TYPE: AL 3 - - A.I.C.: 35K 3 - - M.L.O.: YES 3 - - MAIN CB: 3 - - MAIN FUSE: 3 - - FLUSH: 3 - - SURFACE: YES 3 - - - GND. BAR: YES - - ISO GND: - - 200% NEU: - - FEED THRU: - - DBL LUG: - - TOP FEED: - - BTM FEED: YES - - PANEL T.C.L - - LOAD (kVA) - - RCPT - LTG - EQP 252.6 - - HEAT - - - TOTAL 252.5 - - FEEDER T.C.L - - LOAD (kVA) - RCPT - LTG - EQP 252.6 - - HEAT - - - TOTAL 252.5 - - FEEDER DEMAND - kVA 252.6 TOTAL 252.5 303.7 AMPERES 303.7 252.5 - MFG: CB: NOTE: CABINET LOADS ARE DUAL FED FROM PDU -A AND PDU -B. DESIGN LOAD WILL BE HALF OF THE UPS AND PDU CAPACITY. Project: ICG B3 - 10/21/08 10/21/08 Feeder T.C.L. Is primed here hod[ontatly to Brow a bock "paste-Mk" to the 'Load Distribution- columns of a sub- feed panel or switchboard - I - I 252.5 I - • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL08 -1375 DATE: 10 -21 -08 PROJECT NAME: UNIVERSITY OF WASHINGTON SITE ADDRESS: 12201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: �u -g4-c Buil P g Division Public Works Fire Prevention ❑ Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 10 -23 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11-20-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7TH AVE 5 PO BOX 80467 SEATTLE WA 98108 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601190731 ACTIVE VECAECI542MU ELECTRICAL CONTRACTOR 7/31/1946 10/31/2009 CONTIK *965D6 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License CONTIK *965D6 Name CONTI, KEITH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON AGENT 01/01/1980 829407110 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 SURETY CO WESTERN 829407110 01/06/2007 Until Cancelled $4,000.00 01/06/2007 TRAVELERS https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License = VECAECI542MU 10/28/2008 PANEL LR1 208/3 225A MCB L PANEL HL1 480/3 225A MLO XFMR T -LR1 75 KVA #6 - -,225A HL1 125A LR1 ,---.225A SPARE 900A 277/480 3'4W ,--800A ATS -2 ti1000A SPARE ..�800A ATS -1 800A SBS ( 2000AF 1200AT MCB A 2000M /1 00AT 277/480 3P4W ATS -1 480/3 1200A �$OOA SBC 150A ELS1 400A EHS2 -�30A TVSS • i600A EHM2 - 50A GP • �400A EHS1 600A EHM1 .800A EMSB2 EMSB1 1200A - P4 (3 2-1,/2 "C 4 -350. 1 /oc XHHW PANEL EHM1 480/3 600A MLO PANEL EHM2 480/3 600A M LO PANEL EHS1 480/3 400A MLO PANEL EHS2 480/3 400A MLO XFMR T -ELS1 1 2 KVA #1/O PANEL ELS1 -1 208/3 400A MCB PANEL ELS1 -2 208/3 400A MLO PANEL GP 208/3 100A MCB XFMR T -GP 30 KVA #6 , - �,800A UPS -A 800A MBC -A F �800A UPS -B .BQOA MBC -B EMSB2 $00A 277/480 3P4W (3) 2- -1/2 "C 3 -300. 1 /0G (3) 2-1/2"C 3 -300, 1/00 (3) 2 -1 /2 "C 3 -30 0, 1/0 UPS -A 400 KW 480/3 MBC -A MA NT BYPASS 480/3 800A PDU -A1 132 KW 208/3 250A - PDU -A2 132 KW 208/3 250A PDU -A3 132 KW 208/3 250A - -2-1/2 "C 3 -250, #4G -- 2 -1 /2 "C 3 -250, #4G -(3) 2 -1/2 "C 3 -300, 1/00 -(3) 2-1/2"C 3 -300, 1/00 UPS -B 400 KW 480/3 (3) 2 -1/2" C 3 -300, 4/0N, 1/0 MBC -B MAINT BYPASS 480/3 800A PDU -B1 132 KW 208/3 Ti 250A - PDU -02 132 KW 208/3 250A PDU -83 132 KW 208/3 250A - -°2 -1/2 "C 3 -250, #4G -2 -1/2 "c 3 -250, #4G -(3) 2 -1/2 "C 3 -300, 1 /00 EXISTING 1200A FEEDER TO BLDG SWITCHBOARD MTS -1 480/3 1200A 7p860A 750 KW GEN 480/3 #1/0G / ROLL UP GEN / TERM BOX Amps Number Feeder EMT w/a N 20A FA1 4 #12, #12G 1/2 "C 1/2"C 30A FA2 4 #1O, #10G 1/2"C 1/2 "C 50A FA3 4 #8, #10G 3/4 "C 3/4 "C 60A FA4 4#6, #10G 1 "C 3/4 "C 85A FA5 4#4, no 1 -1/4 "C 1 "C 100A FA6 4#2, #8G 1 -1/4 "C 1 -1/4 "C 150A FA7 4 -1/0, #6G 2"C 1 -1/2"C 175A FA8 4 -210, #6G 2 "C 2 "C 200A FA9 4 -3/0, #6G 2"C 2 "C 225A FA10 4-4/0, #4G 2 -1/2 "C 2"C 250A FA11 4 -250, #2G 2 -1/2"C 2 -1/2 "C 275A FA12 4 -300, #2G 2 -1 /2"C 2 -1/2"C 300A FA13 4 -350, #2G 3"C 3"C 380A FA14 4 -500, #2G 3 -1/2"C 3"C 450A FA15 (2) 4-10, #2G (2) 2 -1/2" (2) 2' 1000A FA16 (3) 4 -350, 1/00 (3) 2 -1/2" (3) 2 -1/2" 600A FA17 (2) 4 -350, 1 /OG (2) 3" (2) 2 -1/2" 850A FA18 (3) 4 -300, 2/00 (3) 2 -1/2" (3) 2 -1/2" 1200A FA19 (4) 4 -350, 310G (4) 3"C (4) 3"C PANEL ELS2 -1 208/3 200A MCB PANEL ELS2 -2 208/3 200A MCB 1 150 KVA o to (0 - PROVIDE MONITORING SIMILAR TO EMSB1 I N 800AF /800AT /3 U U CO EMSB3 800A 277/480 3P4W ATS_2 OOOA 277/480 3P4W Vp800A 600 KW GEN 480/3 /11/00 7-NEW ATS NEW GEN SET LOCATED LEVEL P1 SE FBOIC PANEL EMSB -2 480/3 800A - MLO PANEL GP 208/3 100A MCB (3) 2 -1/2" C 3-300, 4/0N, 1/00 TO NEW 800A CB IN MAIN SERVICE ATS -2 480/3 800A (3) 2 -1/2" C 3 -300, 4/0N, 1 /OG (2) 2 "C 4 -3/0, #30 ti$OOA UPS -C 800A MBC -C SBC TZ- EMSB3 800A 2771480 3P4W EW GENERATOR LOCATED LEVEL P1 SE �1800A FBOIC 600 KW GEN 483 #1/0G UPS -C 400 KW 480/3 T 00, MBC -C MAINT BYPASS 480/3 800A i UPS, MBC, PDU'S / FBOIC PDU -C1 132 KW 208/3 1-1250A - PDU -C2 132 KW 208/3 250A - PDU -C3 132 KW 208/3 250A - - 2 -1/2 "C 3 -250, #40 -2 -1 /2 "C 3 -250, #4G -(3) 2 -1/2 "C 3 -300, 1/00 -(3) 2 -1/2 "C 3 -300, 1/00 UTURE f �225A ELS2 125A SPARE ��125A SPARE .125A SPARE SBC 400A 277/480 3P4W XFMR T -ELS2 150 KVA PANEL ELS2-1 208/3 200A MCB PANEL ELS2 -2 208/3 200A MCB #1 /0 FLOOR 3 PANEL EHM2 480/3 600A MLO N PANEL E-M1 460/3 6004 MLO PANEL EHS1 480/3 OOA MLO PANEL EHS2 480/3 400A MLO PANEL ELS1 -1 208/3 400A MCB PANEL ELS1-2 208/3 400A MLO L0 N N ( to qp (' n 4 CO ( t ( n Q 4 l' to 4 Q ( to 4 4 ( M Q 4 ( j®I 4 N 2,711/4903.1_:,4W_ gum EMSB1 12a16 NEW FEED TO BUILDING MAIN SWBD (3) 2 -1/2" C 3 -300, 4/0N, 1 /OG m ATS -1 1200A E27/480 3P4W MTo1 277/480 3P4W 0) u F1800A vv 750 KW GEN 480 3 #1/0G PANEL HL1 480/3 225A MLO 4 u- PANEL LR1 208/3 225A MCB 4 75 KVA v I RIv RISE- R ro 0 jN 800A a77/480 3P4W /--ROL GEN /! TERM M BOX El 0) u U? u_ MDP 2000AF /1200AT 277/480 3P4W 0) L. SEDER TO 1200A BREAKER IN BUILDING MAIN SWBD 1 DIAL v C' \Vera \Sabey \SDC B3 80473 \SDC B3 elec asbullts ES1A 10- 8- 08.dwg 10/21/2008 100 PM LEVEL P2 MB/IB /ED FO R- CODE COMPLIAN NFPA 70 - NEC OCT 2 4 NB City Of Tukwila „AVM Nisi RILE COPY Permit No.k211,0iii Pi: r review approval b Subject to orro m and cm::. Approval of construction documents darn not 8uihc ::) the violation of any dopted codo or or:.t nanc . f' 7: -1 of approved ` 'Id C py and con 'ons is acktino''Jice fly By Date: City of Tukwila BUILDING DID /SION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division, NOTE: Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED CITY OF TUKWILA OCT 2 1 2008 PERMIT CENTER OWNER: Sabey Corp. 12201 Tukwila Intl Blvd #400 Seattle, WA 98168 Ph 206 - 281 -8700 Fx 206- 281 -0920 CONTRACTOR: Sabey Construction 12201 Tukwila Intl Blvd #400 Seattle, WA 98168 Ph 206 -281 -4200 Fx 206 -281 -0920 00 Lo 0 0 01:>~ rn u1 1 E R a3 y v) d CV CV Ci ..� C\> Z r SO O • >LOi/)11 Ld, w w to v• s 0 m W V/ ila Intl Blvd #300 Seattle , WA 98168 Job Number - ISSUED /REVISED DATE PROGRESS SET 6/12/2006 UPS /RACK LAYOUT 6/16/2006 RACK LAYOUT 6/20/2006 PHASE 1 ASBUILTS 8/29/2006 PHASE 2 9/16/2006 ADD PDU'S & CRAC UNIT 10/21/2008 ONE -LINE DIAGRAM POWER RISER E2.1A /2, OUTLET LABELS PDU #- PANEL -CKT #, L5 -20R RECPT L5 --30R RECPT Q L6 -20R RECPT qv L6 -30R RECPT RI ROUGH -IN ONLY, NO WIRE alp L21 -20R RECPT L15 -30R RECPT d LEV 430009W 30 amp d LEV 460009W 60 amp 0 HUB CS8365c 50 amp BATT BATT BATT UPS -B MBC -@ 400 KW 480/3 MBC A UPS -A BATT BATT BATT 400 KW 480/3 CAC EHM2- 7,9,11 DRY COOLER POWER UP TO ROOF - - -.' CIRC EHM2 2 -10H DRY COOLER EHM2 -13 MCA 16.5 4 N -s3F 3 EMSB3 P 400 KW 480/3 MBC -C BATT BATT BATT ATS-2 MDP 112 T -EL51 UMPS 1,3,5 I E S1- EH S1-1 DAMPER CTRL B1 -4- Al -4- i 127,29 27,29 23,25 23,25 19,21 19,21 4 RI RI RI RI RI 18 14 5 5 16 16 10,12 10,12 B1 -4- Al -4- 0 a 24 2 414Z 24 26 26k4,(;) 14 18,22 6,8 6,8 2,4 2,4 (5) W RES TO EACH CAC B1 -3- Al -3- RI RI 1 5,1', 33 15 ,11',33 11,1',35 11,12,35 7,9,: tQA 7,9,: EH 1 -37 -CTRL WIRES /� EMSB1 B1 -3- Al -3- 12,22,24 12.22,24 15,6,8 19,6,8 14,2,4 14,2,4 EEi1 ,1`G= HVAC CTRL PNL- B 1 -4 -20 / \.• T -LR1 EHS1 -7 J -BOX ATS -1 T -2 ELS1 -2/24 @2 -4- A2-4- RI RI `='x'7,9,1 /\ +i\ �EL51 -20 7,9,1 5,15 5,15 1 1 17 17 1,3,13 1,3,13 114 B2 -4- A2 -4- N 0 0 a 0 o co In M HS1 -13 FLA 86, MCA 102 OP 110 CAC -8 4,22ty' -} 4,22 2,20 2,20 B2 -4- A2 -4- 62 -4- A2 -4- B2 -3- A2 -3--- OOA EHS1 B2 -3- A2 -3- EHS1 -2 EHM1 -37 ONDENSER PUMP OUTLETS (TYP OF EHM1 -25 B2 -2- A2 -2- L /\ A A /\ AA 17,1',21,23 9,11 9,11 13,15 5,7 1,3, ,7 1,3 26, B2 -2- A2 -2- 32,34 A2 -3- B2 -3- B2 -2- A2 -2- A2 -2- 82 -2- 37,39,41 .._ 25,27,29 1,33,35 ,18 2 8 .12 0,42 EHS1 -8 200A 120/208/3 37,39,41 31,33,35 (50'2E A2 -4- B2 -4- EHM1 -38 4/29,31 9,5 21 27 1 ,28,30 A2 -4 B2--4 1A2 -3 B2 -3 It C \Veca\ Sabey \SDC B3 60473 \SDC B3 elec asbullts E51A 10- 8- O8.dwg 10/21/2008 100 PM ELOI 1+C RECEIVED CITY OF TUKWL° OCT 212008 PERMIT CENTER 4 8 12 20 1 /8 " =1' -0" OWNER: Sabey Corp. 12201 Tukwila Intl Blvd #400 Seattle, WA 98168 Ph 206- 281 -8700 Fx 206 - 281 -0920 CONTRACTOR: Sabey Construction 12201 Tukwila Intl Blvd #400 Seattle, WA 98168 Ph 206-281 -4200 Fx 206 - 281 -0920 CO o l() 0 0 Q 0 cq�cvLC) u? o E Z w`LaMj • Lu J (0 (0 (/) d' N N z �.i "- O CD (S) N X U > LOCO O u. co W 12201 Tukwila Intl Blvd #300 Seattle , WA, 98168 Job Number - 79623 ISSUED /REVISED DATE PROGRESS SET 6/12/2006 UPS /RACK LAYOUT 6/16/2006 RACK LAYOUT 6/20/2006 PHASE 1 ASBUILTS 8/29/2006 PHASE 1 ASBUILTS PHASE 2 9/12/2006 9/16/2006 ASBUILTS 10/4/2006 ASBUILTS 7/23/2007 ADD PDU'S & CRAC UNIT 10/21/2008 POWER LAYOUT E5.IA