Loading...
HomeMy WebLinkAboutPermit EL08-1413 - WESTFIELD SOUTHCENTER MALL - CHAMPSCHAMPS 1030 SOUTHCENTER MALI. EL08 -1413 CitApf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1030 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -1413 Issue Date: 01/28/2009 Permit Expires On: 07/27/2009 Tenant: Name: CHAMPS Address: 1030 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: JENNIFER MIRELES Phone: 310 328 -6300 X 105 Address: 1327 POST AV #H , TORRANCE CA Contractor: Name: ABACUS ELECTRIC CO Phone: 253 984 -1611 Address: 9804 SALES RD S STE A -1 , LAKEWOOD WA Contractor License No: ABACUEC928LT Expiration Date: 06/30/2010 DESCRIPTION OF WORK: ELECTRICAL FOR TENANT REMODEL Value of Electrical: $25,000.00 Fees Collected: $615.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: / ` . Date: hi f 7.1 1 I hereby certify that I have read and governing this work will be complie ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: C,�,, Date: 11 2467 Print Name: 1 P- s 1 Y 1f3S--e> This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1413 Printed: 01 -28 -2009 Parcel No.: 6364200010 Address: Suite No: Tenant: CHAMPS City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 1030 SOUTHCENTER MALL TUKW Permit Number: Status: Applied Date: Issue Date: EL08 -1413 ISSUED 11/05/2008 01/28/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: doc: Cond -Elec EL08 -1413 Printed: 01 -28 -2009 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. EI v J 19 I ' Poi -11 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 10 Sam Cr,oa.c,✓Mwll King Co Assessor's Tax No.: (1),APiZ4) ' CNA U Suite Number: 2 e2 t_i Floor: New Tenant: ❑ Yes ❑ ..No Tenant Name: (` 1 "� Property Owners Name:tX11W tii.. ESC a(,vJwv f i'v'es{F -r-i4fGQ LA) Mailing Address LQO tlkhr■it✓ 4N.ic- Ih1 nnow Los AV1 City t A- yoo ZS State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name:j {,V111 -f .C/✓ M Day Telephone:')) / i 3 Z q5 ti 306 Y% I S Mailing Address: [ 2")(921 'PGSf` Aku • $I }-i --rev yew cc CA- go5oi City State Zip E -Mail Address: ,t4 O�j Y ?los Kvali -1 C OYv1 Fax Number: V 3Z 1S 0";302 ELECTRICAL CONTRACTOR INFORMATION Company Name: TP,O Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ t7'5i0-60 Scope of Work (please provide detailed information): Will service be alter d. i Yes ❑ No Adding more than 50 amps? [e Yes ❑ No Type of Use: ' ®NANe I TI "lot Type of work: ❑ New ❑ Addition Service Change Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator BeFire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: (Puget Sound Energy ❑ Seattle City Light H: Appli cat ions lrotnis- Applications On Lined -2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANCES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions S10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: /39-7 I Date Application Accepted: Past Avc -4)6 Date: / / /y /06- 41;/u Day Telephone: &10 32-01.06a-0 1 vvezA-i.e C/1 9oa/ City State Zip Date Application Expires: l Cz H: \Applications,Forns- Applications On Line•4 -2007 - Electrical Permit Application.doc bh Staff initials: I Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http://www.citulcwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -1413 Address: 1030 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/05/2008 Applicant: CHAMPS Issue Date: Receipt No.: R09 -00146 Initials: JEM User ID: 1165 Payment Amount: $615.00 Payment Date: 01/28/2009 09:37 AM Balance: $0.00 Payee: ABACO CONTRACTORS, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5387 615.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES PAYMENT RECEIVED 000.322.101.00.0 492.00 000.345.832.00.0 123.00 Total: $615.00 a....• o......�..� nc OA..4..A• n4 no )nnn INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ik 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 to'S - 113 \a_ Project: /1 APS of Inspection: ;.1.00 ;.1.00 Address: / ®3U �� Date Called: Special Instructions: / Date Wanted: 006 a.m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: IN Date: 63/06/ El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, feeknust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit tio-g-H)3 PERMIT N (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: we, Type of Inspection: ;100 Address: t4 3� Date Called: Special Instructions: Date Wanted: D3/05 p.m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: PA (u/dc pc-PCkill.t7■ff k ON/Okt. of tile/U.6)1 1.-iG sen4 Inspector: -1-rti &NW Date: 03/05(0 El $60.00 REINSPECTION FEE�tEOUIRED. Prior to ins p a n fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit t0481— ILI I INSPECTION NO. PERMIT NO<. CITY OF TUKWILA BUILDING DIVISION }le-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: /) APS of Inspection: 7Q0, Address 030 11 Date Called: �� Special Instructions: Date Wanted: 0211-7 a m p.m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: �. - s70 26R-041- se TT' Inspector 6.6.4.14 Date: Z /07 El $60.00 REINSPECTION FEE REdUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 INSPECTION RECORD Retain a copy with permit £LD- I1-113 PERMIT NO. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: ^ eiti p 5 Type of Inspection: 700, b Address:,0 3 Date Called: Special Instructions: Date Wanted: 0Z (of Requester: Phone No: EApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: PA 0.K. - N164 ul au.5 niJ9 ,.1a�i._ ,D5 - J„rt Yk3 L413 thAIDUIT,5 Inspector: f,1 r __i_ 16r, Date: O1 -I O7 LJ$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1413 DATE: 11 -05 -08 PROJECT NAME: CHAMPS SITE ADDRESS: 1030 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEEP�jARTTMMENTS: i Building Division IVI Public Works Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 11-06-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS R TING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 12-04 -08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by L£tI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ABACUS ELECTRIC CO UBI No. 2539841611 Status 9804 SALES RD S SUITE A- 1 LAKEWOOD WA 98499 PIERCE LIMITED LIABILITY COMPANY ABACO CONTRACTORS LLC License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 602838703 ACTIVE ABACUEC928LT ELECTRICAL CONTRACTOR 6/30/2008 6/30/2010 MOSS *HT928Q4 GENERAL UNUSED ADMINISTRATOR INFORMATION License MOSS *HT928Q4 Name Moss, H TROY JR Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MOSS, HAYWOOD TROY PARTNER /MEMBER 06/30/2008 SMITH, SHANE PARTNER /MEMBER 06/30/2008 Bond Information IBond I Bond Effective IExpiration1Cancel Impaired) Bond https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= ABACUEC928LT Received 01/28/2009 DIVISION XV MECHANICAL DIVISION XV MECHANICAL (CONT.) DIVISION XV MECHANICAL (CONT.) DIVISION XV MECHANICAL (CONT.) DIVISION XVI ELECTRICAL (CONT.) DATE: 10-30-08 JOB NO 0813130 DRAWN: CHECKED: GROSS AREA: 5,535 SQ. FT. SALES AREA 3,278 SQ. FT. sEc. 5000 - MECHANICAL GENERAL PROVISIONS A SLEEVES 1. THE CONTERACTOR SEIALL PROvITDE ELEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE NSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RE$PECT1VE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WI1I-1 EACH SURFACE EXCEPT SLEEVES TEAT F'ENETRATE THE FLOOR, WHICH SHALL EXTEND 2' ABOVE THE FLOOR. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOOR.S SEIALL BE FIRE sEALEID WITH CALCIUM SILICATE, SILICONE 'RTNE FOAM, '3M' FIRE RATED SEALANTS OR EaJAI SO AS TO RETAIN THE FIRE RATING OF THE FLOOFR OR WALL. CONFORM TO U1. ASSEMBLY RATING OF FLOOR OR WALL. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL t5E ST,ANDARD UJEIG1-1T $TEEL PIPE FINISHED UJITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTMONS, TI-HROUGH SUSPENDED CEILINGS, OR FOR CONCEALED vERTICAL PIPING, SLEEVES SHALL BE GALvANIZED STEEL MNIMUM. 4. DI.JCT SLEEvES To 15E MINIMUM 14 GAUGE STEEL. B. HAN4EREE I HANGERS SHALL INCLUDE ALL M1SCELLANEOU$ STEEL SUCH AS AELGLE IRON, BAND& C-CLAMF"S UJITH RETANING CLIP& CHANNELS, HANGER RoDs, ETC., NECESZARY FOR THE NSTALLATION OF WORK 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING OR DUCTWORK HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACEED TO UPPER CHORD OF 15AR JOIST. WHERE INTERPEIRENCES OCCUR IN ORDER TO SUPPORT DUCTUJORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WEIICH SHALL E35 LOCATED WEEIRE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMF'ERS, VALVES, ACCESS DOORS AND OTHER EQUIPMENT SERVICE !REQUIREMENTS AND/OR OTHER TR.ADES. HANGER rrFES AND INSTALLATION METHOD& ARE SUBJECT TO LANDLORD CRITERIA. 3. EIANGERS FofR ALL INSULATED PIPING SEIALL BE SIZED AND INSTALLED FOR TEE OUTER DIAMETER OF INSULATION. INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE I-IANGER AND THE FIFE INSULATION. 4. HANG=T AND PIPING OF DIsSIMILAR METALS 81-IALL BE DI-ELECTRICALLY SEPARATED FROM oNE I-IER. a ELECTRICAL MOTORS: I. FURNISH, INSTALL AND ALIGN ALL MOTORS REQUIRED FOR THIS EQUIPMENT. UNLESS TI-IEY ARE FACTORy INSTALLED ON THE UNIT, ALL 8TAIRTERS AND ASSOCIATED WIRING AND SAFETY SWITCHES FOR $UCH MOTORS SHALL SE FURNISHED AND INSTALLED 151- THE ELEcTRIcAL CONTRACTOR. STARTERS SHALL MEET ALL REQUIREMENTS AS DEFINED IN THE ELECTRICAL DIVISION OP THE SPECIFICATIONS. 2. DESIGN, CONSTRUcTloN AND pERFORMANCE CEIARACTERISTICS OF motoRa $14ALL CONFORM TO ALL APPLICABLE PROVISION$ OF LATEST NEMA, ANSI, ISEE STANDARDS FOR ELECTRICAL EQUIPMENT. ALL MOTORS SHALL IBE $U1TABLE FOR OPERATION ON VOLTAGE VARIATION OF PLUS OR MINUS 10%, 40 DEGREES C 'AMBIENT TEMPERATURE± HAVE A SERVICE FAcToR OF NOT LESS THAN 1.5. D. LOW VOLTAGE (24 VOLT) WIRING: I. TI-1E CONTRACTOR IS TO INSTALL ALL LOW VOLTAGE WIRING REQUIIRED FOR I-115 EQUIPMENT. THIS WORK INCLUDES ALL TRANSFORMERS AND DEVICES TO MAKE TH1$ A COMPLETE FUNCTIONAL 8Y8TEM. 2. ALL WORK IS TO CONFORM TO THE LATEST ADDITION N.E.0 AND TO DlvISION 16 ELEcTRICAL SPECIFICATIONS. 3. ANY CONDUIT REQUIRED I3Y CODE OR TEE LANDLORD WILL IBE INSTALLED f5Y TI-4E ELECTRICAL SUBCONTRACTOR. 4. FLASI-IING 61-IALL BE SEALED WATERTIG1-1T AN1D PERFORMED IN AccoRDANcE To TEE LANDLORD'S CRITERIA USE A LANDLORD APPROVED ROOFNG CONTRACTOR WHERE APPLICABLE. E. RELOCATION OF EQUIPMENT: L RELOCATION OF EXISTING WATER, GAS, WASTE, VENT, OR DRAINAGE LINES TO FACILITATE SToRE DESIGN CRITERIA MUST BE INCLUDED IN SID PROPOSAL. SEC. WOO - SPIRINKLER SYSTEMS A. SPRINKLER SYSTEM: I. SUBMITTALS; a. PROVIDE DATA ON OPRINKLERE, VALVES, AND SPECIALTIES, INCLUDING MANUFACTURERS CATALOG INFORMATION. 5U15MIT PERFORMANCE RATINS, ROUGH-1N DETAILS, WEIGHTS, SUPF'ORT REQUIREMENTS, AND PIPING CONNECTIONS, b. $140P DRAWINGS: I SUBMIT SHOP DRAWINGS OF EINISHED CEILING AREAS INDICATING ONLY SPRINKLER LOCATIONS COORDINATED WITH CEILING NSTALLATIoN. 2. INDICATE HYDRAULIC CALCULATIONS, DETAILED PIPE LAYOUT, HANGERS AND SUPPORTS, SPRINKLERS, COMPONENTS AND ACCESSORIES. INDICATE SYSTEM CONTR.OL$. SLIBMIT $HOF' DRAWINGS, PRODUCT DATA HYDRAULIC CALCULATIONS TO AUTHORITIES 1-1AVING JURISDICTION (INCLUDING 15UT NOT LIMITED TO THE FIRE MARSI-IALL AND LANDLORD) FOR APPROVAL. SEC. 15400 - PLUM15ING A. PLUMING EQUIPMENT: I REFER TO M $1-1EETS FOR EQUIPMENT AND FIXTURE SCHEDULES. EL GENERAL PIPING REQUIRMNTS: I. GENERALLY, SANITARY AND POTABLE WATER TAPS WILL BE PROVIDED BY THE LANDLORD. FIELD VERIFY EXACT CONNECTION POINTS PRIOR TO EUSMITTING BID AND NOTIFY THE TENANT'S CONSTRUCTION MANAGER F CONDITIONS ARE NOT AS 51401IN ON TEE PLANS OR AS STATED IN THE SPECIFICATIONS CONTRACTOR MUST VERIFY THE OPERABILITY CF ENTIRE SYSTEM PRIOR TO TIE IN AS FOLLOWS: a. SNAKE SANITARY FOR A DISTANCE OF 100 FEET AND ?REPORT ANY BLOCKAGE. b. TEST WATER PRESSURE TO INSURE MINIMUM OF E0 PEI. 2. INSTALL ALL NECE$SARY PIPE HANGER& EADDLES, AND CARRIER8 To PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SEALL SUIT TYPE OF PIPING PROVIDED AND 15E SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING UJHERE REQUIRED EYE coDES. 3. EScUTcHEONS SHALL I5E CHR.OME PLATED, SIZE AS REQUIRED AND PLACED AT ALL pipe PENETIRATIONS AT WALLS, FLOORS, AND CEILINGS IN ENISHEID AREAS. 4. FLASHING SHALL BE SEALED LUATERTIGHT AND PERFORMED IN ACCORDANCE TO TI-1E LANDLORD'S CRITERIA USE A LANDLORD APPROVED ROOFING CONTRACTOR WEERE APPLICABLE. C. PIPING: I. EANITARY PEEING - NO PVC ALLOWED (STORM PIPING AS REQUIRED). • WASTE, DRAN AND VENT PIPING SHALL IBE SERVICE WEIGHT, CAST IRON SOIL PIPE. VENT PIPING ABOVE FLOOR 2' OR SMALLER MAY BE GALVANIZED STEEL. b. JOINTS: BELOW FLOOR SLAB - COMPRESSION TYPE PLASTIC SEAL (1-1U5 AND SPIGOT). ABOVE FLOOR SLAB - NEOPRENE SEALING SLEEVE WITH STAINLESS STEEL sHIELD AND CLAMP WITH APPROVED INEOP'RENE - 'BASED LUBRICANT, (HUIBLESS) GALvANizED VENT - ScREu.ED JOINTS WITI-4 TEFLOW TAPE ON MALE THREAD& c. PITCH WASTE LINES 2" AND SMALLER NOT LESS THAN 1/4' PER FOOT. pITci-1 LARGER MAINS NOT LESS THAN 1/5' PER FOOT. d. INSTALL A CLEANOUT AT BASE OF EACH SOIL STACK, AT EACH CHANGE IN DIRECTION, AT INTERVALS NOT OVER 50 FEET, AND ELSEWHERE AS SHOLIN ON DRAWINGS OR nQUIRED BY LOCAL CODE. CLEANOUTS SHALL NOT BE INSTALLED IN PUBLIC AREAS WITHOUT SPECIFIC pERIISSION I5Y TENANT'S CONSTRUCTION MANAGER* BUT WHERE NECESSARY, TEE WALL COVERS ARE TO BE STAINLESS STEEL AND THE FLOOR COVERS ARE TO !BE BRASS (FLUSH WITH FNISEED FLOOR). PROVIDE COVERS WITH INSET AREA FOR CARPETED FLOOR LOCATIONS. ALL CLEAN-OUT LOCATIONS SHALL BE APPROVED BY THE TENANT'S CONETRUCTION MANAGER e. INSULATE ALL HORIZONAL RUNS OF PIPING LOCATED IN CEILING SPACES WI-EN AF'PLICABLE. INSULATION TO 5E AS SF'ECFIED FOR WATER PIPING, r. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2' ARMSTRONG 'ARIAELEX' PIPNG INsuLATIoN OR TRUEBRO MODEL 102W 'HANPI LAV GUARD' INSULATION KIT. 2. coNDENSATE PIPING: a. CONDENSATE PIPING SHALL BE TYPE 'L' IDIRA.UJN COPPER TUBE WITH '35-5 TIN-ANTIMONY SOLDERED JOINTS AND WROUGHT COF'PER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. 3. F'OTAIBLE WATER PIPING: a. BELOW GRADE: TYPE 'K', ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTE. b. ABOVE GRADE: TYPE 'L' DRAUJN COPPER TUBE WITI4 WROUGHT COPPER FITTINGS AND 95-5 TIN-ANTIMONY SOLDER c. INSTALL AIR CHAMBER SI-locK ABOORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. d. ALL BRANCI4 PIPING SYSTEM SHALL HAv'E ACCES$15LE $ERV10E VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. es, PROVIDE WATER METER AND REMOTE READER F'ER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTO IF APPLICABLE. REFER TO PLANS TO DETERMINED IF WATER METER IS REQUIRED. f. SECURE PIPE AT ANGLE STOPS. e. PROVIDE FLEXIBLE 1N$ERTS AT ALL PIPE PENETRATIONS THROUGH FRAMING TO KEEP PIPES FROM HITTING FRAME WHEN IN OPERATION, 4. GAS PIPING PROVIDE A compLete GAS PIPING SYSTEM 1E APPLICABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM IS REQUIRED. b. LOW F'RESSURE (14' W.C. AND BELOW GAS LINES SHALL i8E BLACK STEEL, SCHEDULE 40, ASTM A-120, WITH MALLEABLE THREADED FITTINGS FOR 2' AND SMALLER, AND WITH WELDED JOINTS FOR 2-1/2' AND LARGER MEDIUM F1RESSURE (ABOVE 14' W.C.) SI-ALL HAVE WELDED JOINTS. c. PROVIPE A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT. PROVIDE GAS METER AND/OR REGULATOR AS FREQUIRED. REGULATOR TO SE VENTED To THE EXTERIOR. d. PITCH PIPING AT A UNIFORM GRADE OF 1/4' IN 15 FEET UF'UJARTD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED oN [DRAWINGS, OIR BY et ANDARD INDUSTRY PRACTICE, WHICHEVER 15 MORE STRINGENT. E. GAS PIPING EXPOSED ON TROOP MUST EE PAINTED WIT1-1 fRUST-NHIESITING PAINT. f'. INSTALLATION, TESTING AND PURGNG OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 COIEES. g. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH T1-4E E LOCAL GAS COMP,4NY AND THE MALL'S MANAGER PRIOR TO 51P. sEa 15400 C. PIPING 5. 6. SEC. 15100 A 1-VAC I. 2. 3. 4. 5. 6. 1. 8. - PLUMEING (CONT.) (CONT./ INSULATION: a. INSULATE ALL WATER SNAP-ON FIBERGLASS CODES AND UL FLAME APPROVED MANUFACTURER: TEST 4 STERILIZATION; a. LEAKAGE TESTS SHALL I. TEST POTABLE 2. TEST DRAIN, LUASTE, 14OURS. ALL JOINTS 3. TEST GA8 PIPING 4. STERILIZE PoTA15LE SYSTEM. STERILIZE - 1-IEATING, VENTILATION EQUIPMENT: PRIMARY HEATING, VENTILATION a. PRIMARY HEATING, CORPORATION AS SCHEDULED. EXTENDED WARRANTY. b. EQUALS EQUIPMENT AVAILABLE THROUGH c. ALL EQUIPMENT SEALL DEV10E$, APFURTENANCEe, AN1D OFERATION OF d. EQUIPMENT SHALL BE MANUFACTURER'S INSTRUCTIONS. CONDENSATE DRAIN MANUFACTURERS DATA. a. SECONDARY DRAIN CONDITIONING EQUIpMENT TO pROTEcT ENTIRE SHALL ME DIREcTED VARIABLE AIR VOLUME a. WHERE 61-10U.N ON DRAWINGS, CONTROL$, HEATING FLEXIBLE DUCT/PIPE CONTRACTOR. TOILET ExHAUST FANS: a. WHERE SHOWN ON DRAWINGS, COMPLETE WITH GRAVITY OPENINGS AND CAPS PROVIDED BY THE BASEBOARD, CABINET, AND a. WHERE SHOWN ON DRAWINGS, HEATING COIL, CONTROL$, INLINE PUMPS: a. WI-IERE SHOWN ON DRAWNGS FITTED, PUMPS EHALL SLEEVE AND MECEIANICAL THEY MAY 1BE MOUNTED RPM UNLES$ NOTED IBRATION ISOLATION DEVICES: a. vIBRATIoN ISoLATION vIBRATNG EQUIPMENT ETC.) AND STRUCTURE. b. VIBRATING EQUIPMENT SPRING DEVICES. VIBRATING ISoLATED WITH HoUSED 0. EXAMINE DEAD LoAD SELECTING DEVICES. •'GROUNDING' T1-4E ISOLATOR. d. CHECK HANGER ROD THE UPPER ANID LOWER et CON$ULT MANUFACTURER CURBS AND STEEL FRAMING a. TI-IIS CONTRACTOR WILL TO INSTALL ALL 1-MAC 54-IALL IBE A MINIMUM SUPPORTED. INeULATE ALL CURBS MUST BE PENETRATIONS OF EXI5TING LANDLORD'S GUIDELINES METAL DUCTWORK: a. NO FIE3ERGLA5S DUCT b. No DUcTUJoRK :*IALL TENANT'S CONSTRUCTION APPROVED 5Y TENANT'S INSTALLATIoN. ti .L ALL DUCT BRANCHES coNNEcTIONS TO THE cr. EXCEPT AS OTHERUJISE RECTANGULAR DUCTS 'HVAC DUCT CON$TRUCTION REQUIREMENTS h4 TEE TYPES AND INTERVALS, d EXCEPT WHERE OTHERWIEE FOLLOWING F'RESSURE POSITIVE OR NEGATIVE 1. SUPPLY DUCTS: 2. RETURN AND EXHAUST PRESSURE. PRESSURE JOINT$ AND APPLY SYSTEM THAT DOES CLASS RATINGS E. AS A MINIMUM, CROSSBREAK APPROXIMATELY 3/0' f'. INSTALL DOU5LE THIcKNESS g. INSTALL RIGID R.OUND IN SMACNA STANDARDS. AND WITHIN 4 FEET OF EACH sIDE OF FITTING. AND ,AT EACH FLOOR PROVIDE SWAY AND IBY LANDLoRD. h. WHERE DUCTS PASS 1-1/21X1-1/2' XI/81 STEEL ANNULAR 5F'ACE BETWEEN SEALANT OR FIREPROOEEP I. ALL TRAVEREE JOINTS WITH PAP CMC DUCT SEEET METAL scREWS. j. SOFT ELASTOMER !BUTYL FLANGED JOINTS. k DUcT TRANSITIONS SHALL SPECIFICALLY NOTED I PROVIDE ACCES$ TO CONTROLS, AND OTHER INSPECTIoN. IF THE 15E APPROVED MY TEE LAY-1N SUPPLY AND FRAMES MAY BE USED m. FLEXII5LE CONNECTIONS: I. FLEXIBLE COLLARS BETWEEN VIBRATING HANDLERS, FAN CASINGS. ALSO, CROSS BUILDING 2. FLEXIBLE CONNECTIONS NEOPIRENE-COATED JOINT FLEXIBILITY TRAN$M1e$ION OF 3. FLEXIBLE CONNECTION PRESSURE OF THE n. FIRE DAMPERS: 1. ' PROVIDE PRIMARY DAMPERS ;31-1ALL REQUID, FIRE 2. FIRE DAMPERS FUSIBLE LINK, rrpe 3. PROVIDE ALL NECESSARY AND CODE REQUIREMENTS. 4. PROVIDE DUCT DAMPERS. DOOR AND PIANO HINGE. ';‘::4'- -PARATE PERMIT Qc REQUIRED FOR: d Mechanical pjlectriCal grifiumbing I! Gas Piping City of Tukwila BUILDING DIVISION -,- AND INTERIOR CONDENSATE PIPING WITH l' THICK (K.0.23 PIPE INSULATION WITH AN ALL SERVICE JAcKET TO MEET BF'READ RATNG OF 25 AND SMOKE DEVELOPED R.ATINGS MANVILLE MICRO-La< 5E PER LOCAL. coDES, MINIMUM AS FOLLOWS: WATER PIPING AND CONDENSATE PIPING AT 125 PSIG FOR VENT PIPING 13y A 10' WATER COLUMN FOR TWO SEIALL IBE GAS AND WATER TIGHT. PER NEPA 54 coDEs. HOT AND coLP WATER LINES UpON COMPLETIoN oF WATER SYSTEM N ACCORDANCE WITH LOCAL CODE 4 AIR CONDITIONING AND AIR CONDITIONING UNITS: VENTILATION, AND AIR CONDITIONING UNITS ARE TO 5E By ALL COMPRESSORS ARE TO INCLUDE A 5-YEAR AS MANUFACTURED IBY CARRIER OR YORK IF NOT REASONAME EFFORT. BE COMPLETE IN EVERY RESPECT WITH ALL AND ACCESSOR1E$ PROVIDED TO MEET THE DESIGN THE SYSTEMS S140U.N ON THE DRAWINGS AND SPEcIFIED 1N$TALLED IN STRICT ACCORDANCE WITH THE ALL AIR CONDITIONING EQUIPMENT MUSTHAVE AND BE TRAPPED N ACCORDANCE WITH SEE DRAWINGS FOR ADDITIoNAL DETAILs. PANS ARE REQUIRED TO DE INSTALLED BENEATH ALL I WITH T1-4E ExcEPTION OF vAV 'BOXES. SEcoNDARTr UNIT. pRovIDE coNDENSATE FUMPS, AS REQUIRED. co TO MOP' SINK OR AS EPECIFIED ON PLANO. BOXES (VAV) PROVIDE VAV 150XES COMPLETE WITH COILS (FANS AS REQUIRED). ALL DUCT CONNECTIONS CONNECTIONS SHALL BE PROVIDED BY TEE PROVIDE A TOILET EXHAUST PAN UNIT BACK DRAFT DAMPER& ALL DUCTWORK, ROOF NECESSARY TO PROvIDE A COMPLETE EXHAUST SYSTEM CONTRACTOR REFER TO PLANS FOR APPLICABILITY. UNIT HEATERS: pRovIDE ELECTRIC HEATERS COMPLETE WITH ELECT AND INTEGRAL THERIOSTAT. PROVIDE AN INLINE CLOSE COUPLED FUMF(S), 15E FURNISHED WIT1-4 BRONZE CASE WEARING RINGS, BRONZE SEAFT SEAL RATED FOR. PUMPS TO BE SO coNSTRUCTE IN A 1-10RIZONTAL oR VERTICAL FEEE LINE. MOTOR TO OTHERWISE. DEvIcES 54-IALL BE PIEOVIDED IN ALL SUPPORTS BET (FAN8, ROOFTOP UNITS, AI IR HANDLERS, FAN POWERED I-IUNG FROM STRUcTURE SHALL 15E ISOLATED WITI-I RUE3 EQUIPMENT SUFF'ORTED FROM FLOOR OR DECK SPRING MOUNT DEVICES. AND opERATING LOAD coNDITIoNS WHEN ADJUST FOR PROPER ALIGNMENT AND LOADING. AVOI SIZE FOR ALLOWABLE LOADS AT THE ISOLATING DEVIC ATTACHMENTS TO STRUCTURES, DUCTS, EQUIPMENT, ETC. FOR APPLICATION DATA FOR SUPPORT; PROVIDE ALL NECESSARY CURBS AND STEEL FRAMING EQUIPMENT AS DESCRIBED OR IMPLIED ON THE RAW OF 14' 1-11G1-1, OF TI-1 E SAME MANUFACTURER OF TEE EQUIPMENT UNDER TEE COMPRESSOR SECTION TO PREVENT CQNPENSA NSTALLEP So TWAT Top OF cUR155 ARE 'DEAD' LEvEL. STRUCTURE SHALL SE DONE IN ACCORDANCE T AT THIS CONTRACTOR'S EXPEN$E. ALL0WEID. BE FABRIcATED PRIO R TO APPRovAL BY THE MANAGER SIGNIFICANT DEVIATIONS FROM DESIGN MU-5T CONSTRICTION MANAGER PRIOR TO FABRICATION OR DUcT MAINS ARE To ME RECTANGULAR UNLESS NOTES OT TO DIFFUSERS ARE TO SE ROUND RIGID DUCT. (FLEXIBLE DIFFUSER ARE NOT TO EXCEED 5-01). INDICATE, FABRICATE AND INSTALL WITH GALVANIZED SEEET STEEL, IN ACCORDANCE WITH STANDARDS' OF THE LATE$T EDITION. CONFORM REFERENCED STANDARD FOR METAL THICKNESS, REINFORCI TIE ROD APPLICATIONS, AND JOINT TYPES AND INTERVALS. INDICATED, CONSTRICT DUCT SYSTEMS TO THE CLASSIFICATION& (VERIFY WHETHER RETURN OR EXI4AUST PRESSURE). 2 INCHES WATER GAUGE, poSITIvE PRESEURE. DUCTS: 2 INCHES WATER GAUGE, NEGATIVE TEST DUCTS FOR LEAKAGE. REMAKE LEAKING SEALANT$ AS REQUIRED TO FABRICATE A NOT EXCEED 5% LEAKAGE OR LESS AS STATED 15Y IN SMACNA STANDARD8. ALL FLAT SURFACES OR REINFORCE WITH A 15EAD WIPE X 3/16' DEEP ON 12' CENTERS TO PREVENT VIBRATION& TURNING VANES IN ALL RIGHT 'ANGLE ELBOWS. AND RECTANGULAR METAL DUCT WITH SUPPOR SYSTEMS SUPPORT HORIZONTAL DUCTS WITI-IIN 2 FEET OE EACH EACH BRANCH INTERSECTION USING DOUBLE WRAP HANG SUppoRT VERTICAL DUcT5 AT A MAXIMUM INTERVAL OF NO WOOD SHALL BE USED TO SUPPORT OR BRACE DUCTS SEIEMIC !BRACING AS REQUIRED BY STATE AND LOCAL THROUGH ROOFS AND FLooRs, pRoviDE AS MNIMUM ANGLE FRAMES AT EACH siDE cif opENING. THE DUCT AND ANGLE FRAMEE 51-1ALL 15E CAULKED WITH AS F2EQUIRED BY ASSEMBLY FIRE RATING. AND SEAMS IN SUPPLY AIR DUCT SHALL BE SEALED AIR SEALER. JOINTS ALSO SHALL BE RIVETED OR CONNECTID GA8KET WITH ADHESIVE BACKING SHALL BE USED T NOT EXCEED 30 DEGREES SLOPE EXCEPT AS OTEERUJISE. ALL MOTORIZED PAMPERS FIRE DAMPERS ITEMS IN DUCTWORK THAT REQUIRE EERVICE OR ACCESS PANEL LOCATION IS EXPOSED TO THE SALES AREA TENANT'S CONSTRUCTION MANAGER PRIOR TO INSTALEATI RETURN AIR DIFFUSERS, GRILLES AND REGISTER5 WITH PLASTE AS ACCESS LOCATIONS. SEIALL 155 PROVIIDED IN ALL CONNECTIONS EQUIPMENT (FANS, ROOFTOP UNITS, AIR POWERED VAV !BOXES, ETC.) AND Duo-re OR PROVIDE FLEXIBLE COPINECTIONS WHERE DUCTS EXPANSION JOINTS. SHALL CONSTRUCTED OF FLAMEPROOF FABRIC. PROVIDE ADEQUATE TO ALLOW FOR MOVEMENT AND PREVENT THE VIBRATION. IS TO 15E RATED FOR TI-IE OPERATING SYSTEM. FIRE DAMPERS WHERE INDICATED OR REQUIRED BY BE DESIGNED FOR 140RIZONTAL OR VERTICAL FLOW OF DAMPERS SEIALL SE UL LABELED. S4-ALL HAVE T14E BLADES OUT OP THE AIRSTREAM AND A, 45 MINIMUM. FRAMING AND SLEEVES FOR !DAMPER MOUNT! ACCESS DOORS IN AN ACCESSABLE LOCATION FOR ALL IS TO BE 20 GA GA-VANIZEID !DOOR WITH QUICK-OPENING p piermItFI:Lo: FY far rev.Ow Epproval la subiect to errors and Approvq1 f , o construction documents d . ow not the violation I code or ordinan of approved Fiel Copy and con By o any adopted , ons is ac! te.-...------ Datc....t e 9 .• Citi of Tukwila E3 , ULDING DMSION 0 -I 1-0pAL • SIX T IN -IEREI A 0 • PAN DEN SH • BRONZ I, BE EN AV E•XES, EFR • $HAL AND RE NGS. ALL TI-E ERUI D UT omA TO TH I D PRES IND' EL 16 TEE elLI TIG WI SEA IT OPE AIR Ar 1650 PE MIRE L mist auth . e Re MiitiCi F) 50. OURS, ENT AIR ARE ATE LL BE IC AT THAT 150 IBE AT IRED US ION. 1 1 T 18 RE ATM, ON ET OR ONE T UST . UL CH ions . ' rszo . cv t L,n , gt..'d: o. FLEXIBLE AIR DUCT: • 1. FLEXIBLE AIR DUCT $HALL BE 1" IN5ULATED CLASS I AND RATED FOR NE OPERATING PRESSURE OF THE SYSTEM, DUCT CONSTRUCTION MATERIAL- (PLASTIC, CLOTH, ALUMINUM) MUST ADHER.E TO LOCAL CODES AND LANDLORD'S REQUIREMENTS AND BE INCLUDED AS SUCH N THE BID. 2. FLEXIBLE AIR DUCT MAY ONLY 13E USED N vERTICAL APFLICATIONS WITH PRIOIE APPROVAL FROM TENANT'S CONSTRUCTION MANAGER 3. FLEXIBLE DUCT SEIALL NOT EXTEND OVER 5coo N LENGTH AT ANY ONE LOCATION. P SUPPLY AIR TAKE-OPE EITINGS: L PROVIDE CONICAL OR 'BELL-MOUTH' TAKE-OFFS FROM MAIN DUCTWORK TO ROUND BRANCHES. INSTALL PER MANUFACTURER'S NSTRUcTIoNS. 2. PROVIDE 45. RECTANGULAR TAKE-OFFS FROM MAIN DUCTWORK TO RECTANGULAR BRANCHES. q. DAMPERS: 1. pRovIDE MANUAL LOCKING QUADRANT voLUME CONTROL PAMPERS WITH HANDLE OPERATOIRS IN EAci-I BRANcH DUCT AND AS SHOWN oN PLANS TO FACILITATE AIR BALANCING. 2. WHERE ACCESS TO BALANCING PAMPER IS RESTRICTED, YOUNG'S REGULATORS 51-IALL BE USED. 3. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR RELIEF AIR OR RETURN AIR DUCTS ARE TO 1BE OF OPPOSED BLADE TYPE. ALL OUTSIDE AIR DUCT DAMPERS MUST ALSO BE OF THE LOW LEAKAGE TYPE. 4. ALL MOTORIZED PAMPERS NOT FURNSHED WITH EQUIPMENT ARE TO BE HONEYWELL DAMPER.S. r. DIFFUSERS, GRILLES AND REGISTERS: 1. PROVIDE DIFFUSERS GRILLES AND FZEGISTERS AS SCI-IEDULED. 'DEVICES TO E3E COMPLETE LIJITI-1 DAMPERS FRAMES AND ALL AccESSofRIES. FINI81-1 A5 INDICATED. 2. INSTALL ALL AIR DEVICES AS LOCATED CM THE ARCHITECTURAL REFLECTED CEILING PLAN. 3. AppRovED MANUFACTURERS: TITUS 15 SFECIFIEP, EQUALS BY METALAIRE OR KRUEGER IS ACCEPTABLE. 8. MEDIUM PRESSURE DUCT 1. WI-IERE DUCTWORK IS SPECIFICALLY NOT AS MEDIUM PRESSURE, IT SI-IALL BE cONSTRUCTEp IN AccoRDANCE WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 3 INCI-IES UJATER COLUMN MINIMUM OR LARGER AS REQUIRED 15Y LANDLoRD. 2. ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LATEST EDITION OF SMACNA STANDARDS FOR MEDIUM PRESSURE DUCT AND WITH TI-4E LANDLORD'S CRITERIA 3. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY To THIS SECTION sEa 15'100 - 1-IE4TING, VENTILATION 4 AIR CoNDITIoNING (CONT.) 6. METAL DUCTWORK. (CONT.): t. DUCTWORK INSULATION I INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFAcTURERIS WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH FECOGNIZED INDUSTRY PRAcTIcES. INSULATION MUST COMPLY WITH NEPA 90A, 2, DUCT SIZES SHOWN ON DRAWINGS ARE INEIDE CLEAR DIMENSIONS. INSULATE SUPPLY AND RETURN AIR RECTANGULAR DUCTWORK WHERE SHOLIN ON PLAN. DUCTWORK SHALL BE INTERNALLY INSULATED WITH 1 THICK I-1/2 LB. DENSITY LINER (C2028 • 15f). LINER IS TO 1-1AVE A COATED SURFACE EXPOSED TO AIRSTREAM To pREvENT ER0810N. APPLY ADEESIVES AND MECHANICAL FASTENERS AS RECOMMENDED BY SMACINA AND THE MANUFACTURER TO PREVENT LINER SEPARATION FROM THE DUCT. ALL TRAN$VERSE EDGES TO 15E COATED WITH ADI-EEIVE. 3. ALL ROUND AND OUTSIDE AIR DUotWORK ABOVE THE CEILING SEIALL BE EXTERNALLY INSULATED WITH A MINIMUM OF I'THICK, 1-1/2 LE3. DENSITY (FRN5.6) DUCT WRAP WITH VAPOR 15ARRIER VAPOR BARRIER 15 TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS V18IBLE. EXTEND 'DUCTWORK INEULATION WITHOUT NTERRUPTION THR.OUGH WALLS, FLOORS, AND SIMILAR PENETRATION5. 4. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEvELOpED RATING OF NO HIGHER THAT 50 WHEN TESTED IN AccoRDANcE WITH ASTM c 411, OR AS REQUIRED ImY LOCAL coDES. u. SYSTEM CLEANOUT L DUcTWoRK AND AIR HANDLING EQUIPMENT IS TO !BE CLEANED OUT AND IBLOEN OUT BEFORE PAINTING IS STARTED BY THE GENERAL CONTRACTOR. 2. FILTERS MUST 15E IN UNITS AT ANY TIME FANS ARE OPERATED. E. HYDRONIC PIPING: a. PROVIDE A COMPLETE HYDRONIC plpING SYSTEM IF AFPLICABLE. REFER TO PLANS TO DETERMINE IP A 1-1YDRONIc SYSTEM IS REQUIRED. b. HyDRONIC PIPING FOR cmiLLED WATER AND/oR HEATING WATER AND/OR CONDEN$ER WATER SHALL BE ASTE1 A-I20, SCHEDULE 40, ERIU,15LACK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2-1/2 INCH AND LARGER - INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS OR INSTALL TYPE 'K' ANNEALED TEMFERED COFFER TUBE WITH SILFOS JoNTS FOR 2 INcH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT coNFoRMANcE WITH ASTM, ASA AND LANDLoRD'S REQUIREMENTS, WHICHEVER IS MOST STRINGENT. UNIONS OR FLANGES MUST i5E USED AT EQUIpMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. c. ,ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. d. ALL HyDR0Nic PIPING AND EQUIpMENT coNNEcTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREENS. FILL TENANTS SYSTEM WITH DoMESTIc WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR SHALL NOT PILL TENANT'S SYSTEM WITH WATER FROM THE LANDLove SYSTEM UNLESS SPECIFICALLY INSTRUCTED TO DO SO FROI THE LANDLORD'S FIELD REPRESENTATIVE. e. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION FROM TEE LANDLORD'S FIELD REPRESENTATIVE, TEAT ,ALL TESTING, FLUSHING, AND PROPER FILLING OF THE TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLopvs REQUIREMENTS AND TEAT THE TENANT'S SYSTEM IS READY TO IBE CONNECTED TO TI-4E LANDLORD'S SYSTEM. E. VALVES: I. GATE VALVES, 2-INCH AND SMALLER: CLASS 150, BoDy AND UNION moNNET oF ASTM 15 62 CAST BRONZE WITH THREADED OR SOLDER ENDS, INTEGRAL SEAT, RENEUJABLE SOLID 'BRONZE UJEDGE DISC, RISING STEM, SCREWED BONNET AND RE-PACKABLE UNDER PRESSURE. I5ALL VALVES ARE ACCEPTED AS AN EQUAL SUEsSTITUT1oN. 2. GATE VALVES, 2-1/2 INCH AND LARGER.: CLASS In CAST IRON DOPY, RENEWABLE BRONZE SEATS AND SOLID WEDGE DISC, RISING STEM FLANGED ENDS, AND RE-PACKABLE UNDER PRESSURE. 3. $WING CHECK VALVES, 2-INcH AND SMALLER: CLASS MO, CAST BRONZE BODY AND CAP CONFORMING TO AeTtl 5 62 WITH HORIZONTAL SWING, Y-PATTERN, RENEWABLE BRONZE D1Sc, AND HAVING THREADED OR $OLDERED ENDS. 4. SWING CHECK vALvE, 2-1/2 INCH AND LARGER: CLASS 125 CAST IRON BODY AND MOLTED cAp, HoRIZoNTAL SWING, RENEWAME MR-OWE DISC, FLANGED ENDS AN1D CAPABLE OF BEING REFITTED WEILE THE VALVE REMAINS IN T1-E LINE. 5. COMBINATION BALANCING AND SHUT-OFF VALVES: [3ELL 4 GOSOETT CIRCUIT SETTER WITH LOCKING SETPONT. A CIRCUIT SETTER BALANCE WHEEL MUST IBE NCLUDED WITH 0 4 m MANUAL. 6. FLOW METER BELL AND GOSSETT THERMOFLO INDICATOR MODEL TFI. g. PIPING SPECIALTIES: L pREsSURE/TEMpERATURE TEST PLUGS ( PETE1$ PLUG) - 1/4 INCH NEI FITTINGS TO RECEIVE EITHER A TEMPERATURE OR PRESSURE PROBE, 1/8 INCH O.D. FITTING AND CAPS EHALL SE IBRA$S WITH VALVE CORE OF NORDEL, RATED AT 400 PSIG, Of TO 200•R 2. STRAINERS - 'Y' PATTERN STRAINERS, 125 POIG, CAST IRON 'BODY WITH PERPORATED STAINLESS &TEEL SCREEN, THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2-1/2 INCHES AND LARGER SCREEN OPENING SIZE AT 0.033 INCH FOR I-EATING AND I/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH OLOUJIDOWN VAI-VE WITH 1-10SE EN ID FITTING. 3. THERMOMETERS - DIE CAST ALUMNUM, 9' INDUSTRIAL MERCURY THERMOMETER, FULLY ADJUETABLE WITH CLEAR ACRYLIC WINDOW AND !BRASS SEPARABLE SOCKET. 4. MANUAL AIR VENTS - WEE COIN-OPERATED VENT. PROVIDE AN AIR CEAMBER CONSISTING OF A 3/4' NIPPLE AND BUSI4INGS. h. GENERAL INSTALLATION: I INSTALL WATER MAINS WITHOUT PITC1-1. USE ECCENTRIC REDUcING COUPLINGS Al AT CHANGES IN SIZE WITH THE TOP OF PIPES AT EAME ELEVATION. MAKE CHANGES IN DIRECTION WITH FITTINGS 2. BRANCHES TO UNITS E3ELOW MAINS TO 13E TAKEN FROM BOTTOM OF MAINS AT A 45 DEG ANGLE, PITCH DOWNWARD TOWARD LINITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1' TO 10 FEET. HANGERS 61-IALL BE SIZED AND INSTALLED FOR THE OUTSIDE DIAMETER OF THE INEULATED PIPE, INSTALL 6' LONG SPLIT CIRCLE GALVANIZED SADDLE EETUJEEN TEE 1-4ANGER AND PIPE INSULATION. 4. HANGERS AND PIPING OF 'DISSIMILAR METALS 614ALL BE DIELECTRICALLY SEPARATED FROM ONE AN0THER. 5. SEE PLANS FOR APPLICABLE DETAILS. 6. ALL pRESSURE PIPING SYSTEMS INSTALLED SHALL CONFORM TO THE REQUIREMENTS OF THE STATE PIPING AND WELDING CODES. 1, INSTALL VALVES AT LOW POINTS FOR DRANING EACH SYSTEM AND INSTALL MANUAL VENTS AT ALL HIGH POINTS OF EQUIPMENT ANID PIPING 114 THE SYSTEM TO PROPERLY REMOVE ENTRAF'PED AIR. I. INSULATION: I ,41-1- HYDRONIC PIPING FO 1R CI-IILLED WATER AND/OR 1-IEATING UIATER., VALVES, FITTINGS, AND ACCESSORIES &HALL IBE INSULATED. FOR PIPE eine UP TO 2 INCHES, INSULATE WITH 1 INCH THICK (K.023 • lEf FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2-1/2 1NCI-4E5 AND LARGER, INSULATE WITH I-1/2 NCH THICK (K.023 • 15P) FIESEE4LASS INSULATION WI714 ALL SERVICE JACKET AND VAPOR BARRIER, 2. INSULATION AT ALL HANGER5 FOR PIPING 2-1/2 iNcHES AND LARGER SHALL ME HARD AND NON-COMPRESSIBLE. 3. ALL INSULATION SHALL HAVE A FLAME eFfiEAD RATING OF NoT MoRE TI-1,4N 25 AND A SMOKE DEVELOF'ED RATING OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMENTS oF THE NEPA. SilE ,.. r VISICPIS he SCOPe \\\'6 'N, p,E____.----ie to t- 4 ..--Th ,...r. rna'-' .„,..„‘0.31 01 hail '-' \ hanges s , A ntiot aPP‘) 00 C.- 1( VvithOt" r DIVIVOn • ..,rota% \ ot wot . Boding „Ian sou WM TON v -rti . Ulla a .e ,ees. . • ...slam mg 1 ,.,Ian rev% ,... fieVISLOE d60:1119. V 140 1 'nclUde a and Mall 10. REFRIGERANT FflING a. pROvIDE A COMPLETE REFRIGERANT PIPING $Y$TEM BETWEEN INDOOR FAN UN1T$ AND OUTDOOR CONDENENG UNITS, IF AF'PLICABLE. PROVIDE OIL, REFRIGERANT CHARGE AND TEST 8YSTEM. REFER TO PLANS TO DETERMINE IF A !REFRIGERANT PIPING SYSTEM 15 REQUIRED. Is. MATERIALS: 1. REFRIGERANT PIPING SHALL BE TYPE "L' DRAWN COPPER TUBING (ATM WE) , WROUGHT COPPER OR CAST BRONZE FITTINGS (ANSI 516224 WITH SILFOS-5 SOLDEFED JOINTS. 2. SERVICE VALVES, CHARGING PORTS, FILTER-DRIER, SIGHT GLASS, AND A THERIOSTATIC EXPANSION VALVE (TXV) SI-IALL BE 1N$TALLED FOR EACH SYSTEM A$ A MINIMUM. e. INSTALLATION: L SIZE LINES WITH ADEQUATE LIFT TRAPS AND DOUBLE SUCTION RISERS AS NECESSARY TO MEET THE NEEDS OF EQUIPMENT SPECIFIED, FIELD CONDMON$, AND EQUIPEENT MANUFACTURER'S RECOMMENDATIONS. 2. PRESSURE 'TEST FoR LEAKS WITH AN INERT GAS AT 250 pea REDO LEAKING JOINTS AND RETE$T UNTIL EYETEM IS TIGHT. EVACUATE GAS AND CHARGE $Y$TEM. RE -TE5T SYSTEM AND CHECK FOIR LEAKS WITH EIALIDE LEAK DETECTOR. ALL LEAKING JOINTS MUST IBE COMPLETELY RE-DONE UNTIL NO LEAK $ EXIST. 3. UPON coMFLETION OF TESTNG, BUT BEFORE INSULATION IS APPLIED, PIPING MUST BE 1N$PECTED 15Y A REPRESENTATIVE OF TEE LOCAL GOVERNING AUTHORITY AS NECESSARY. 4. REFRIGERANT LINES SHALL BE INSULATED WITH 1 INCA THICK RUBATEX OR ARMSTRONG TREFRIGERANT PIPE INSULATION IN ACCORDANCE WITH INDUETRY STANDARDS. sEC 15'520 - TESTING, ADJUSTING 4 SALANCING A SYSTEM TESTING, ADJUSTING, AND BALANCING: 1. TESTING, ADJUSTING AND E3ALANcING OF ALL UJORK SEIALL BE MADE BY AN INDEPENDENT CONTRACTOR WHO 18 CURRENTLY LICENSED Ae$OCIATED AIR BALANCING COUNCIL (AABC) OR NATIONAL ENVIRONMENTAL 15ALANcING BUREAU (NE) BALANCING CONTRACTOR- NO OTHER BALANcE REPORTS WILL I5E REVIEWED OR ACCEPTED, ALL BALANcING WORK MUST BE coMpLETE AND DoNE IN ACCORDANCE WITH THE MOST RECENT STANDARDS oF TI-IEIR SOCIETY. PAYMENT OF ALL COSTS FOF2 TESTING SI-IALL BE MADE E3Y THE HvAC CONTRACTOR. . INSTALL NEW FILTERS IN ALL UNITS PRIOR TO THE AIR BALANcE. THE CoMPLETE AIR BALANCE EHALL TAKE PLACE WITH OUTEIDE AIR DAMPERS N MINIMUM POSITION. 3. BALANCE AIR AND WATER QUANTITIES TO WITHIN + 5% OF THAT INDICATED ON THE DRAWINGe. ANY REs:PUIRED CHANGES IN SHEAVES, BELTS, PULLEYS, OR THE ADDITION cF DAMFERS REQUIRED TO ACHIEVE SP SH ECIFIED FLOW RATES ALL I5E FE WORMED 5Y 11-IE I4V4C coNTRACTOR WITH No ADDITIONAL CoST To THE TENANT. 4. THE BALANCE REPORT EI-IALL INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION: a. AA15C OR NE 55 CERTIFICATION NLIMEER AND SIGNATURE OF BALANCING cONTRACTOR b. NSTRUMENTATION LIST WITH LAST cALIBRATION DATES. c. MAKE AND MODEL NUMBERS OP ALL I-1V4C EQUIPMENT TESTED. d. AIR CFM AND STATIC pRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PIToT TUBE DUCT TRAVERSE AT TEE UNIT. et. MOTOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. f. NOT AND FAN RFMS, SHEAVE SIZES AND I5ELT SIZES. e. ouTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AT FULL COOLING. h. WATER BALANCE DATA INCLUDING Gpti WIT1-1 INLET AND OUTLET TEMPERATURE AND PRESSURE READINGE (WHERE APPLICABLE). 1. MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. J. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETUIREIS WHERE DUcTED). k. INDEXED FLAN WITH DIERJSER AND RETURN LOCATIONS. 5. ALL CONTROL SEQUENCES SHALL BE TESTED (INTERI-OCKED EQUIPMENT, SMOKE DETECTORS, SMOKE EVACUATION, ECONOMIZER Eta) AND OPERATING STATUS RECORDED IN TEE REPORT. 6. THREE COPIES OF TEE BALANCE REPORT SEIALL BE SUBMITTED TO THE TENANT'S coNSTRUCTION MANAGER FOR ApPROvAL. sEa se2o - TESTING, ADJUSTING 4 EALANCING (CONT.) A SYSTEM TESTING, ADJUSTING, AND BALANCING (CONT.): 1. PEIRFORM ALL APPLICABLE TESTING AND SALANcING FINCTIONS QUIRE FOR THE SYSTEM DESIGNED IN THESE CERAWINGS. RECHECK ANY ITEMS THAT TEE TENANT DEEMS NECESSARY AT NO ADDMONAL COST TO THE TENANT. 8. FINAL BALANCE REPORT SHALL BE INCLUDED IN THE OF'ERATION 4 MAINTENANCE MANUALS. 5.. FINAL HVAC INEPECTION: I. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, T14E TENANT SHALL 1-1AVE THE RIGEIT TO AN INDEPENDENT EIVAC CONTRACTOR INSPECT TEE FINISHED HvAC INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS, AND coDES. THE INSTALLING CONTRACTOR WILL SE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT HVAC CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS AT NO COST TO TENANT. P . 1N$TALLATION: 1. ALL ELECTRIC WORE $44ALL I3E INSTALLED 50 AS TO 15E READILY ACCEE$1BLE FOR OPERATING, SERVICNG, MAINTAINING, AND IREF'AIRING. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL ELICH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL E3E FASTENED TO Est/ILI:ENG STEEL, CONCRETE OR MASONRY, BUT NOT PIPING OIR DUCTWORK ALL CONDUIT SHALL BE CONCEALED WHEREvER POSSIBLE. ExPOSED CONDUITS $HALL BE N STRAIGHT LINES PARALLEL WITH OR AT RIGI-IT ANGLES TO COLUMN LINSE OR !BEAMS AND SEPARATED AT LEAST 3 INCHES FROM UJATER LINES WHEREVER THEY RUN ALONGSIDE OR ACROSS SUCH LINES. ALL CONDUCTORS SEIALL BE IN coNDUIT, DUcT5 OR OTWER CODE AP'PROVED RACEWAYS. 2. ALL. LINE AND LOW VOLTAGE POWER AND CONTROL WIRING (EXCEFT HVAC LOW VOLTAGE WIRING) INCLUDING CONNECTIONS TO MOTORS, DAMPERS, INTERLOCKING, ETC 14ALL BE PROVIDED. (RESPONSIBLE FOR ALL LINE VOLTAGE WIRING, CONDUIT, AND FINAL CONNECTIONS FROM THE F'OWER SOURCE TI-IRU THE STARTER/DIScoNNEcT ETc. TO THE MOTOR OR EQUIFMENT. ALL HvAc RELATED LOD voLTAGE CONTROL WIRING, CONDUIT AND INAL CONNECTION E 15 THE RESPONSIBILITY OF TEE MECHANICAL/TEMPERATURE CONTROL. CONTRACTOR, UNLESS OTHERWISE NOTED ON THE FLAW. 3. DO ALL CUTTING, CHASING OR CHANNELING AND PATCHING REQUIF:ED FOR ANY WORK UNDER THE ELECTRICAL. DIVISION, AND CUTTING SHALL HAVE PRIoR APPROvAL oF THE LANDLORD. SLEEvES SHALL EXTEND AT LEAST TWO (2') NCEES ABOVE ENISI-ED FLOOR AND ALL SLEEVES, OPENINGS, ETC., THRU FIR:E RATED WALLS AND FLOORS SHALL BE FIRE SEALED WITH CALCIUM 8ILICATE, SLICONE 'RTV' F0AM, '3M' FIRE RAM SEALANTS OR EQUAL BY HILTI AFTER CONDUIT/CABLES INSTALLATION f30 AS TO RETAIN THE FIRE FEATING, 4. TEE FOLLOWING EQUIPMENT SHALL 13E IDENTIFIED UJITH ENGRAVED BAKELITE NAMEPLATES AS TO NAME AND/OR FUNCTION* DISTRIBUTION PANELS, LIGHTING PANELS, MOTOFR STARTERE AND DISCONNECT SWITCHES. NAMEPLATES TO 15E APPROXIMATELY l' X 2' IN SIZE AND BE FA$TENELD WITH Fop RIVETS OR OCRELUS. 5. THE LOCATION OF OUTLETS AND EQUIMENT SHOUN ON THE DRAW1NG$ ARE APPROXIMATE AND THE ARCHITECT/TENANT PROJECT MANAGER SHALL 14AVE THE ERIGEIT TO RELOCATE ANY OUTLETS OR FIX-TURES BEFORE THEY ARE INSTALLED WP'-' 'T ADDITICELAL COST. 6. PFZOTECT ALL FIXTURES/EQUIPMENT AGAINST DAMAGE FROM LEAKS, ABU-SE, ETC., AND PAY CO5T OF REF'AIR OR REPLACEIENT of FIXTURES oR EQUIPMENT MADE NECESSARY BY FAILURE TO PROVIDE SUITABLE SAFEGUARDS OR PROTECTION. 1. MAKE ALL FINAL ELEcTRIcAL CONNEcTIONS AS REQUIRED FOR A COMPLETE AND oPERATING SYSTEM. AFTER ALL EQUIFMENT HAS BEEN INSPECTED AND APPROvED, THOROUGI-ILY cLEAN ALL EQUIPMENT PRovIDEP UNDER THIS WORK JUST PRIOR TO coMpLETIoN oF PROJECT. 8. PERFORM ANY/ALL NECES8ARY ELECTRICAL DEMOLTION WORK THAT IS REQUIRED TO FACILITATE TI-4E NEW NSTALLATIoN FIELD cOORDINATE PRIOR TO BIDS. REMOVE AND/OR MODIFY EQUIPMENT, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. ANY EQUIPMENT OR DEVICE RETUNING IN USE AFTER PART OF THE EQUIPMENT OR DEVICES I-IAVE BEEN REMOvED ARE TO BE RECONNECTED TO EXISTING OR NEW CIRCUITS AND LEFT IN WORKING ORDER FEEDERS TO PANELS AND WIRING TO OTHER EQUIPMENT TO 55 ROUTED CONCEALED N ENIEHED AREA& COORDINATE ANY DISRUPrTIoN OF ELECTRICAL OR TELEP1-10NE SERvICES WITH LANDLORD AND TENANT PROJECT MANAGER TO Avolp CONFLIcTS. SEC. 16100 - WIRING mETwoos A CONDUITS: I CONDUIT $14ALL 15E STANDARD ETEEL RIGID, INC OR EMT (THIN WALL) ACCORDING TO LOCAL CODE AND LANDLORD REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FNISHED AREA5, EXCEPT AS OTHERWISE APPROVED IBY ARCI-IITECT. EMT CONNECTIONS SHALL EE COMPRESSION OR SET ECREW TYPE. 2. FLEXIBLE CONDUIT OR TYPE MC CABLE SEIALL IBE USED FOR FINAL CONNECTIONS TO LIGHT FIXTURES, MOTORS AND veR.ATING EQIIIPMENT ONLY* AND WHERE 50 USED To BE GROUNDED WITH A $EPARATE FULL SIZED GREEN GROUNDING CONDUCTOR FINAL TYPE MCFLEX CONNECTIONS SHALL. 13E LIMITED TO 81-0' IN LEINGT14 (ARRANGE CIRCUITS SO AS TO AVOID THE USE OF JUNCTION MOXES ABOVE DRYWALL CEILING AREAS, JUNCTION BOXES LOCATED AE3OVE LAY-IN CEILINGS ARE ACCEPTABLE). a. MINIMUM SIZES OF CONDUITS SHALL IBE 3/4' FOR $TANDARD CONDUIT, AND 1/2' FOR FLEX CONDUIT (I/2' STANDARD CONDUIT AND 3/8' MC CABLE MAY E3E USEP AS SPEcIFIED ABovE, IF AcCEPTABLE WITH LANDLORD AND LOCAL coDES, ELECTRICAL CONTRAcTOR SHALL FIELD COORDINATE WITH LANDLORD 4 INSPECTION AGENCIES PRIOIR TO INSTALLATION). ELECTRIC METALLIC TUBING (EMT) SHALL 15E GALvANIZED OR ELECTRO-GALVANIZED. FITTINGS SEALL IBE SET SCREW OR COMPRESSION TYPE, FITTING SHALL BE AS MANUFAcTURED BY FEGEL, STEEL CITY, RAco, T 4 B, EFC0fR OR EQUAL. EMT SHALL BE USED FOR FEEDERE AND BRANCH CIRCUITS RUN ABOvE SUSFENDED CEILINGS OR CONCEALED IN INTERIOR PARTITIONS. b. PAINT ELECTRICAL CONDUITS, ETC., IF REQUIRED, 3. THE USE OF ROMEX OR I3X 1$ NOT PERMITTED. 4. MANIMUM CONDUIT I-IANGER SPACING SHALL BE V-0' FOR 3/4' THRU 1-1/4' AND 10'-0' FOR I-1/2' TERU 4' CONDUITS. EgE NOT SUPPORT CONDUIT FR.om THE CEILING SYSTEM. 5. LEAVE A 310 AWG PE LL WIRE OR NYLON PULL STRING IN ALL EMPTY CONDUITS 6. SECURE ALL RACELLE XS TO THE 15UILDING STRUCTURE IN A RIGID AND SECURE MANNER, USING FASTENERS SUCH AS 'CADDY CLIPS' OR EQUAL. 1. FLASH AND COUNTER FLASH ALL RACEWAYS WHIcH FENETRATE THE ROOF OR USE FITai-1 POCKETS INSURE TWAT PENETRATIONS ARE COMPETELY WEATHERPROOF. ALL RACEWAY SYSTEMS EXPOSED TO TEE UJEATHER SHALL 5E UJEATHERPROOR PRIOR APPROVAL. BY LANDLORD IS REQUIRED TO ADD ADDITIONAL EQUIPMENT LOADS TO STRICTURE OR TO MAKE 140LES IN EXISTING ROOF. NOTIFY LANDLORD'S ROOFING CONTRACTOR AT LEAST 12 1-1OUR5 PROIR TO ANY REQUIRED ROOF WORE- 5. UJIRE: 1. WIRE SHALL I3E SINGLE CONDUCTOR COPPER WITH 600 VOLT INSULATION. MNIMUM WIRE SIZE WALL 15E 012 AWG, ALL WIRE AND cA5LE SHALL BE NEW AND SHALL BE BROLIGI-IT To THE SITE IN UNBROKEN FAcK.?,,,ES. ALL WIRING OF ANY TYPE 51-IALL EE IN CONDUIT, NO ETRANDED WIRE ALLOWED FOR '"-'10 AND *12 AU.* SIZES. (INCREASE CONDUcTOR BY ONE SIZE FOR EVERY 150' INCREMENT OF DISTANCE FROM THE PANEL BOARD F-OR 120 VOLT CIRCUITE.) a. GENERAL WIRINt s SHALL BE THEN OR TENN. ALUMNUM CONDUCTORS ARE NOT PERMITTED. 2. UJIRE CONNECTORS &WALL BE EQUALETO 8COTELOCK FOR 413 AND SMALLER, AND EQUAL TO T 4 5 'LOCK-71'TE' FOR f*'.E AND LARGER. 3. THE US E OF SHARED INEUTRALE 15 ACCEPTABLE FOR LIGHTING AND RECEPTACLE CIRCUITS IF NSTALLED IN ACCORDANCE WITH NEC. *310, AND LOCAL CODES. sEC 16300 - TRANSMISSION 4 DISTROUTION A WIR.ED GROUND SYSTEM I. FURNISH AND INSTALL A COMPLETE WIRED GR.OUNDING SYSTEM FOR ELECTRICAL EQUIPMENT AND CIRCUITS AS SHOLN ON TEE DRAWINGS AND DESCRIBED GENERALLY BELOW. 2. ALL GROUNDING CONDUCTORS SEIALL BE GREEN, WHERE EXPOSED IN PANEL, SUJITCHIBOARD, OUTLET, BOXES, ETC. 3. ALL ENCLO$URES AND NON-CURRENT cARRYING METALS To ME GRoUNDED. CONDUIT SYSTEM TO BE ELECTRICALLY CONTINUOUS. ALL LOCK NUTS MUST CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WEERE ENCLOSURES AND NON-CURRENT CARRYING METALS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS LUITH APPROVED CLAMPS. 4. RUN A SEPARATE GROUNDING CONDUCTOR IN EACH CONDUIT, *12 MINIMUM, OR AS SHOWN ON DRAWINGS. FOR PANEL FEEDERS ON THE GROUNDING cONDUCToR TO THE CONDUIT, UJHERE ENTERING AND LEAVING THE CONDUIT. ALL GROUND CLAMPS SI4A1-1- BE PENN-UNION OR EQuAL, SIMILAR TO IGPL' TYPE. CONDUIT GROUND ElusHINGe SHALL BE THOMAS 4 METTs oR EQUAL, SIMILAR TO It'.4300 SERIES WITH NYLON INOULATED THROAT. 5. ,ALL DEVICES 5J-ALL EE 'BONDED TO THE CONDUIT SYSTEM. USE A !BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL TO METAL CONTACT 'BETWEEN THE 'DEVICE. YOKE AND TI-4E CUTLET 1BOX IS NOT ACCEPTABLE AS A BOND F0fR EITI-4E SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION recxEa, OUTLET BOXES AND FULL BOXES SHALL ME BONDED TO TEE CONDUIT SYSTEM. ALL FLEXIBLE CONDUIT 5I-1ALL 15E JUMPERED WITH A GROUND CONDUCTOR 8. SERVICES: I. &HALL PROVIDE TEMPORARY SERVICE FROM LANDLORD'S DESIGNATED LOCATION AND PRoviDE LIGHTING, POWER AND WIRING AS REQUIRED TO FACILITATE APPLICABLE TEMPORARY WIRING, FUSES, ETC, BI-IALL BE REMOVED UPON COMPLETION OF TEIE PROJECT. PROVIDE GRouND FAULT PROTECTION AS REQUIRED BY NE.C. AND LOCAL CODES. 2. PROVIDE ELECTRICAL SERVICE AS SEIOLUN ON THE DRAWINGS, FIELD VERIFY EXACT REQUIRMENTS PRIOR TO BIDS. RESPONSIBLE TO PROVIDE ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR POWER COMF'ANY. CLO$ELY COORDINATE ENTIRE INSTALLATION WITH LANDLoRD AND POWER COMPANY AS REQUIRED. (pRoviDE EQUIPMENT THAT 18 COMPATABLE WITH AVAILABLE FAULT CURRENT LEVELS, PROVILDE 'CABLE LIMITERS' IF NECESSARY FOR SYSTEM COORDINATION). FIELD VERIFY EXACT TYPE, SIZE, LOCATION, REQUIREMENTS, ETC. OF EXISTING POWER AND TELEPHONE FACILME5 PRIOR TO 15ILEDING PROJECT. 3. MAKE PROVISIONS FOR NEW TELEPHONE SERVICE AS REQUIRED, AND AS INDICATED ON THE DRAWINGS. D. CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION WITHIN TENENT'S PREMISES $HALL SE PROVIDED ,A$ REQUIRED FOR A COMF'LETE TELEPHONE SYSTEM. OUTLET BOXES SHALL 1BE 4' EQUARE MINIMUM WITI-I SINGLE PEvIcE COVER ANID TELEPHONE PLATE. CLOSELY FIELD COORDINATE WITH TENANT'S PROJECT MANAGER TO AVOID CONFLICTS. SEC. 16500 - LIGHTING A LIGHTING: I. LIGHTING FIXTURES AND LAMPS SHALL EE FURNISHED At3 Sci-IEDULED. INSTALL ALL FIXTURES AND LAMP& FLUORESCENT FIXTURES SHALL HAVE EIFF !BALLASTS WITH EFFICIENCY FACTORS IN ACCORDANCE WITH INIATIONAL APPLIANCE ENEF*Y CONSERVATION ACT OF 1581, AMENDMENTS OF 1988'. 2. LIGI-IT FIXTURES SHALL 13E SUPPORTED FROM THE BUILDING STRUCTURE VIA AL I- THREAD AND UNI-STRUT, AND No SUppoRTED !BY CEILING SYSTEM. RECEIVED UV NOV PERMIT ili, - - - --. ------ - . -- ...., ------: - --- Emphasis M•Retail 750 Westerville, TEL FAX: _ - - _ On Excellence Engineering, Inc Brooksedge Blvd. Ohio 43081 614.818.2323 61 4.81 8.2337 -I _..1 Ct 00 00 I- Z 1.-L-I 0 ri.*/- CO 0") ff.) 1....LI < EEO Iffilli MM en EM., STORE NO C h 1 I- F- Z D 0 °- D Nr) NO 0 CO (1) am ps: 14498 D l- DIVISION XVI ELECTRICAL SEC A. 15. D. E. ieeso - 15ASIC ELECTRICAL MATERIALS 4 MET-1O WIRE DEVICES: L COLOR OF WIRING DEVICES AND COVERPLATE$ WALL BE SELECTED BY OWINER (SEE PLAN NOTES FO FR ADDITIONAL INFORMATION). a. RECEPTACLES SHALL BE 20 AMP, 3-UJIRE GROUNDING TYPE EQUAL TO HUBBELL 5362. b. SWITCEIES SHALL IBE 20 AMP SPECIFICATION GRADE, RATED AT 120 OR 211 VOLT AS REQUIRED. c. SPECIAL DEVICES SEIALL IBE A SPECIFICATION GRADE, d. ALL DEVICE COVERPLATES *31-4ALL BE STAINLESS STEEL. 6. FLOOFR BOXES TO SE HUEBEL 15-2N1/25 WITH 5-3925 BRAS'S COVER (OR EQUAL SY 'STEEL CITY') AND HUBSELL 5362 RECEPTACLE (UNLESS OTEERWISE NOTED). f. EQUAL 1BY ARROW-HART, GENERAL ELEcTRIc, BRYANT, PASS 4 SEYMOUR, OR SIERRA. PANEL BOARDS AND SAFETY SUJITcI-l5: I PROVIDE BRANCH CIRCUIT PANELS WHICH OHALL BE OF TEE !BOLTED CIRCUIT BREAK-ER TYPE WITH SOLID COPPER BUSSING FULL SIZED NEUTRAL, 25% GROUND BUSSING, OVERALL 1-1INGED/LOCKA8LE DOOR AND TYPtURITTEN DIRECTORY INSIDE DOOR. ALL SERVICE ENTRANCE EQUIPMENT SEIALL !BEAR THE MANUFACTURERS LABEL WHICH SHALL STATE THAT THE EQUIPMENT IS !RATED FOR SERVICE ENTRANCE APPLICATION IN ACCORDANCE WITI4 NEC . *230-10. LOAD BALANCE ALL ELECTRICAL PHASES AT PANELS AND SWITcoARDs. TWO AND THREE POLE BREAKERS SHALL I9E COMMON TRIP TYPE. WHEN USED AS SWITCHES IN 120V. AND 211V. LIGHTING C1RCUIT$, FURNIEH TYPE 'SUED' 15REAKERE N ACCORDANCE WITH N.E.C. 1240-8313. SQUARE P OR EQUAL IBY GOULD ITE, CUTLER-I-AMMER, U.ESTINGI4EXISE, CHALLENGER, FEDERAL PACIFIC OR GENERAL ELECTRIC (OR APPROVED EQUAL) 2. PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NONFUSELE, AS CALLED FOR ON DRAWINGS AND AS REQUIRED BY CODE. (FU$ES AS MANUFACTURED BY BUSSMAN, CHASE SHAWMUT, UJESTINGHOUSE, ECONOMY FUSE CO., OR LITTLE FUSE CO ARE ACCEPTABLE.) DISCONNECT SWITCEIES THAT ARE INSTALLED AT AIR CONDITIONING EQUIPMENT, I4EAT PUTIPS, ETC WALL mE FUSED IN ACCORDANCE WITH THE EQUIPMENT'S NAME PLATE REQUIRMENTS FER N.E.C. 440-21 4 110-3B. SWITCHES SHALL BE 1-1EAVY DUTY, QUICK MAKE/QUICK BREAK TYPE, FU5IE3LE oR NON-FUSIBLE, WEATHERPROOF AS INDICATED ON 1I-4E DRAWINGS, OR AS REQUIRED BY LOCAL CODES. LOAD AND 1-1ORSEF'OWER RATED AS MANUFACTURED 1BY SQUARE D, GOULD ITE, CHALLENGER CUTLER HAMMER WESTINGHOUSE, FEDERAL PACIFIC, OR GENERAL ELECTRIC (OR APPROVED EQUAL). 3. MANUAL MOTOR STARTERS WITH OVERLOAD PROTECTION MAY BE usED FOR FRACTIONAL HORSEPOWER MOTOR.5 THAT EEO NOT REQUIRE AUZILIARY CONTROL. $1NGLE PHASE STARTERS SI-IALL 155 SQUARE ID OR EQUAL. THREE PI4ASE STARTERS SEALL BE PROVIDED WITH ovERLoAD DEvIcE IN EACH PHASE MATCHED TO MOTOR NAMEPLATE RATING. MAGNETIC MOTOR $TARTERS (MINIMUM SIZE *1) SHALL BE USED FOR ALL SINGLE PHASE AND THREE HASE MOTORS FRATED ABOVE 1/2 1-1P OR THAT REQUIRED AUZILIARY CONTROL. PROVIDE CONTROL [DEVICES (CONTACTS TRANSFORMERS, Eta) IN STARTERS AS FZEQUIREID FOR INTERLOCKS COMBINATION STARTERS,WHEN USED, 54-4ALL CONTAIN FUSIBLE SWITCHES. BOXES: I OUTLET BOXES AND COVERS $HALL BE GALVANIZED, ONE-PIECE PRESSED STEEL KNOCKOUT. 2. JUNCTION, PULL BOXES AND COVERS 81-1ALL BE GALVANIZED STEEL, coDE GAUGE SIZE. 3. INSTALL 150XES RIGIDLY ON !BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE/PROPER BOX ENTENSIONS TO EXTEND BOXES TO FNISI-4E D FACES OF WALLS ETC. ALL OUTLET 150XES TO HAVE SUITABLE 13LOCKING BEHND mem TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING/UNPLUGGING INTO THESE DEvICES. 4. UJHEIRE A 211 VOLT LIGHT SUJICH IS GANGED WITH A 120 VOLT RECEPTACLE PROVIDE A sU1TABLE DIvIDER OR SEPARATE JLNCTION 150XES IN ACCORDANCE WITH N.E.C. AND LOCAL CODES. STEP-DOU.N TRANSFORMER: L PROVIDE A DRY-TYPE TRANSFORIER OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWINGS AND WITH COILS DESIGNED FOR 150 DEGREES a RISE ABOVE A 40 DEGREE a AMBIENT WITH 100 % OF RATED LOAD CONNECTED TO THE SECONDARY, CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS (TUX) ABOVE AND FOUR BELOW NORIAL) SOUND LEVEL/DECIBELS 54-IALL ME IN ACCORDANCE WITH 'NEMA' STANDAR:DS, AND INSTALLATION SHALL INCLUDE KoRFoUND OR EQUAL VIBRATION-DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS TO MNIMIZE SOUND TRANSMISSION. (MOUNT TRANSFORMER ON UTEPEIRAIN SEPARATE VJIELINRACITIONI°N wISITOHLAANTOYRSINT, ;14GRAESEL AZECTAcl,D1R?rIT INCSA5TALL VLEIEDRAV TelONRATISOIDNLAI60TOLRSATOANZA.1:: MANLFACTURED 15Y SQUARE P, 1-1EAVY DUTY, ACME, ri 0 3 i.,,, OF TUKWILA 0 5 2008 CENTER J , 0 or Efc' V "7 E"0153 07 Al s ' .. E , ( 0 E . rj ' 35495 `0C) .or , 109 / 11 REVISIONS NO. DESCRIPTION DATE LID S EEN.E. ) /owl 1 SI SHEET NUMBER MECHAN AND ELECTRICAL CI SPE FICATIO I CAL NS GENERAL ELECTRIC OR WESTINGHOUSE. LIGHTING CONTACTORS: CONTACTORS FOR coNTRoL oP LIGI-ITING AND SIGNS SHALL 15E SQUARE 'D', CLASS 6505, TYPE 'L', ELECTRICALLY wELD. EQUIVALENT PRODUCTS 15Y OTHER MANUFACTURER.S ARE PERMITTED. TIME OWITCHES &HALL 15E u$ED FOR CONTROL OF SHOW WINDOW LIGHTING, SIGNS, AND IP REQUIRED/DESIRED OTHER LIGHTING. 71-1E ELECTRONIC DIGITAL TIME SWITCH SHALL IBE A TORK MODEL DWZ100A OR EQUIVALENT WITH A 1-PAY FORMAT, 365 PAY ADVANCED HOLIDAY SCHEDULE, CAPAI5LE OF DIFFERENT SETTINGS EACH DAY OF TI-4E LUEEK, AND HAVE AN AS QU VA TRONOMIC FEATURE, OR E I LENT PRODUCTS SY OTHER MANUFACTURERS ARE PERMITTED xINGisTSINGAREFIESCLDHEcMoNATDICIT.IDNVISsIT. TLI-41: coNSITETPIRRAIDOTRLOALBL ALRIDA5DROP CANDONTRACT IPINDCINGLUID°RE ALAWL TIDOESINIGNSF'EPCRAT EW MATE IA' NECESSARY FOR FIELD MODIFICATIONS 1:)1.4E TO EXISTN G coNDMONS. CONTACT THE OUJNER PRIOR TO BIDDING FOR INTERPRETATIONE AND CLARIFICATIONS OF THE DESIGN ,AND INCLUDE N 1-11.3 EsID ALL coSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY TEE OMER AFTER BIDDING WILL BE FINAL AND SHALL DE IMPLEMENTED AT CONTRACTORS COST. HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCEe. INCLUDED IN BIDS, THE COSTS FOR ALL WOW INSTALLED IN STRICT ACCORDANCE WITH GOVERt+IING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. TEE CONTRACTOR SHALL ALERT OENER OF ANY APPARENT DISCREPANCIES /BETWEEN GOVERNING CODES AND DE$1GN INTENT. ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT 61-101EN TO REMAIN IS FULLY !REMOVED AND NOT ABANDONED. 1 G1 2 0 SPECIFICATIONS 0 FIELD VERIFY ALL CONDITIONS : ' w Ou DATE: JOB NO: 0813130 DRAWN: CHECKED: GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. 10 -30 -08 r0 MANAGER'S DESK 6 -21 13,15,1" I;19 TO TELEPHONE` M. Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 SOUND SYSTEM FAX PHONE PRINTER MODEM (TYP) (TYP) 5-2 6-10 AHU- I T -STAT i B -26 8 -25 1(5-12 ' I � +18'+ 1E6 El COMPUTER PHONE IN HANDICAPPED AREAS, THE RECEPTACLES AND TELEPHONE OUTLETS SHALL BE MOUNTED AT 24' AFF.t THE TOGGLE SWITCHES, THEii'105TATS AND MANUAL MOTOR STARTERS SHALL BE MOUNTED AT 42' A.F.F. POWER PLAN SYMBOL DESCRIPTION WIRED JUNCTION BOX DUPLEX RECEPTACLE, 3 WIRE G. TYPE, 20,4 MOUNTING I4GT TO CENTERLINE UNLESS 01I4ERWISE NOTED SEE DRAWINGS IS A.F.F. (TYP) DUPLEX RECEPTACLE, WEATNERPROOF,20A 18' A.F.F. (TYP) DESCRIPTION MOUNTING WGT. TO CENTERLINE UNLESS OTHERWISE NOTED DESCRIPTION MOUNTING WGT. TO GENTERLN+E UNLESS OTHERWISE NOTED MANUAL MOTOR STARTING SWITCH W/ PILOT LIGIH1 TELEPHONE OUTLET 2 TELEPHONE OUTLET - DUPLEX 48• AFF. (TYP) FIRE ALARM BREAK STATION 48' A.F.F. (TYP) 18' AFF. (TYP) FIRE ALARM AUDIOVISUAL SIGNAL DEVICE 80' A.F.F. (TYP) 18' AFF. (TYP) SMOKE DETECTOR GFI GROUND FAULT PROTECTED DUPLEX RECEPTACLE, 2@A 18' A.F.F. (TYP) QUADRAPLEX WALL RECEPTACLE, 20A DATA OUTLET - CATEGORY 5 I8' A.F.F. (TYP) FIRE ALARM VISUAL SIGNAL DEVICE DATA OUTLET - DUPLEX CATEGORY 5 I8' APP. (TYP) PANIC EXIT DOOR LOCK 80' AFF. (TYP) - REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC NOV 13 200$ City of Tukwila i BUIL©INQ ©IV152 G.F.I. W /LIGHT 4 SWITCH 11 SAFETY SWITCH PUSHBUTTON STATION MAGNETIC MOTOR STARTER DUCT SMOKE DETECTOR LOW VOLTAGE BUZZER TRANSFORMER DOOR BUZZER 54' AFF. (TYP) so. I@ TOGGLE SWITCH - SINGLE, 3 -WAY 4 4 -WAY 48' AFF. (TYP) j COMBINATION STARTER/SAFETY SWITCH MOTOR OUTLET - I PHASE 0 TERMOSTAT STORE NO. Champs: 14498 NT`,! 0 3 2E:3 AS REQUIRED D-- ZONE DAMPER (� MOTOR OUTLET - 3 PHASE ELECTRICAL S YM OL S I-I E D U L ALL 6/713°L6 DO NOT Nl CE6eARILY APPLY 2 0AMP, 120V., ISOLATED GROUND/DEDICATED CIRCUIT RECEPTACLE (HUBBELL *IG -5362) FOR CA514 REGISTERS. DO NOT INSTALL WITH ANY OTHER CIRCUITS. LOCATE RECEPTACLES AT CASH/WRAP COUNTER AS DIRECTED BY OWNER/ARCHITECT. RUN 2 *12 TNWN,1 *12 GRD AND 1 *12 ISOLATED GRD. PER CIRCUIT IN 1' CONDUIT IN FLOOR SLAB TO WALL, RUN UP WALL TO J -BOX AND CONNECT TO CIRCUIT INDICATED. 1' CONDUITS RUN UNDER FLOOR. CORE AND PATCH FLOOR AS REQUIRED. COORDINATE FLOOR CORING WITH LANDLORD PRIOR TO STARTING WORK SEE DETAIL 'F' ON SHEET E1.0. SEE DETAIL 'K' ON SHEET E4.1 FOR TELEPHONE REQUIREMENTS. 2 0AMP, 120V., DUPLEX RECEPTACLE AT CASH WRAP COUNTER FOR UTILITY POWER. LOCATE RECEPTACLES AT CASH WRAP COUNTER AS DIRECTED BY OWNER. RUN 2 12 THLUN AND 1 *12 GRD IN 1' CONDUIT IN FLOOR SLAB TO WALL, RUN UP WALL TO JUNCTION BOX AND CONNECT TO CIRCUIT INDICATED. 2 0AMP, 12 @V., ISOLATED GROUND/DEDICATED CIRCUIT, RECEPTACLE (HUBBELL *IG -5362) MOUNTED AT 18' A.F.F. DO NOT INSTALL WITH ANY OTHER CIRCUITS RUN 2 12 THWN, 1 *12 GRD AND 1 *12 ISOLATED GRD. IN SINGLE 3/4' CONDUIT BACK TO PANEL FOR COMPUTER TERMINAL. SEE DETAIL 'K' ON SHEET E4.1 FOR TELEPHONE RISER DIAGRAM I' CONDUIT FOR CASH REGISTER WIRELESS ACCESS POINT. RUN 314' CONDUIT FROM CASH WRAP COUNTER TO DATA OUTLET /JUNCTION BOX AT MANAGER'S DESK COORDINATE REQUIREMENTS WITH OWNER/ARCHITECT. REFER TO CABLE BLOCK DIAGRAM DETAIL A ON SHEET E4.0. FLUSH MOUNT IN CEILING (1) 20 AMP. (I.G. HOSPITAL GRADE) DUPLEX RECEPTACLE. COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS. SEE DETAIL G ON SHEET E4.1. REFER TO POWER RISER ON SHEET E3.0 FOR MORE INFORMATION. /7\ RECEPTACLES AND COVERPLATES WITH AN 'SF' DESIGNATION SHALL BE FLUSH MOUNTED IN CEILING AT STOREFRONT, PARALLEL TO STOREFRONT GLASS. CIRCUIT TO PANEL AS INDICATED. (NEC ART. 210-62) POWER CODED NOTES 12 13 14 15 16 17 18 21 22 23 25 AS REQUIRED MOTOR OPERATED DAMPER MOUNT SALES AREA DUPLEX RECEPTACLES AND COVERPLATES AT WHERE RECEPTACLES ARE LOCATED BEHIND WALL PANELS, MOUNT HORIZONTALLY AT 8' A.FF- CIRCUIT TO PANEL A5 INDICATED. RECEPTACLE SHOULD 5E MOUNTED AT 6' -0' AFF FOR CCTV. COO EXACT LOCATION WITH CONSTRACTION MGR IN FIELD. DEDICATED RECEPTACLE FOR SOUND SYSTEM MOUNTED ON SHELF. NERDY EXACT REQUIREMENTS WITH SOUND SYSTEM COMPANY 'CROWS NEST AT ( 25) 643 -5 @33. SEE DETAIL 'I' ON SHEET E4.I FOR REAR DOOR BUZZER SYSTEM. CO THE EXACT LOCATION WIT TINE PROJECT MANAGER. SEE DETAIL 'J' ON SHEET E4.1 FOR PANIC EXIT DEVICE. 3/4' EMPTY CONDUIT WITH PULL STRING FROM AHU -1 TO THERMOSTAT MECHANICAL DRAWINGS FOR EXACT LOCATION AND DETAIL 15/E4.L REFER TO HVAC ELECTRICAL CONNECTION SCHEDULE ON SHEET E3.� FO PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN CONCEALED L AND FINAL CONNECTION FOR 120 VOLT SIGN. SIGN FURNISHED BY TENANT. COORDINATE EXACT LOCATIONS WITH TENANT'S CONSTRUCTION MAN 4 E WIRE THROUGH TIME CLOCK. REFER TO LTG CODED NOTE *2 ON SH ET E @ AND POWER RISER ON SHEET E3.0 FOR MORE INFORMATION. MOUNT DUPLEX RECEPTACLES HORIZONTALLY BELOW COUNTER CO RDI EXACT LOCATION WITH CABINET MANUFACTURER RECEPTACLES AND COVERPLATES IN NON -SALES AREA 51-1ALL BE 1`1OUN 18' AFF. UNLESS NOTED OTHERWISE. CIRCUIT TO PANEL AS INDICATEi. CAMERA * 1 FRONT ENTRANCE PUBLIC VIEW (MINI DOME)ADVANCED (FUEL (PENDANT MOUNT)COLOR CAMERA w /4 -8.0mm AIVF LENS FIXED CAMERA *2 (MINI DOME)SALES FLOOR FACING THE STORE COLOR CAMERA w /4 -8.0mm AIVF LENS FIXED CAMERA • 3 (MINI DOME)SALES FLOOR FACING: THE STORE COLOR CAMERA w /4 -8.@mm AIVF LENS FIXED CAMERA *4 (MINI DOME)CAMERA ABOVE THE REGISTER COLOR CAMERA w /4 -8.0mm AIVF LENS 18° A,FF.. INAT RDI ATE RE CONDUIT, AND CIRCUIT REQUIREMENTS AND DETAIL 'B' ON SWEET E41. R TO WIRING, CATION ATE ED AT C VIEW 27 FIXED CAMERA * 5 (MINI DOME)ENTRANCE TO STOCK ROOM COLOR CAMERA w /4 -5,0mm AIVF LENS FIXED CAMERA * 6 (MINI DOME)ENTRANCE TO STOCK ROOM COLOR CAMERA w /4 -8.0mm AIVF LENS FIXED CAMERA *1 (MINI DOME/SALES FLOOR FACING THE STORE COLOR CAMERA w /4 -8.0mm AIVF LENS FIXED CAMERA * 8 (MINI DOME)DROP SAFE COLOR CAMERA w /4 -8.0mm AIVF LENS 31 FIXED CAMERA * S (MINI DOME)SERVICE DOOR COLOR CAMERA w /4 -8.0mm AIVF LENS 32 FURNISH AND INSTALL A 20A /IP MOTOR -RATED SWITCH FOR WATER HEATER 1.5 KW, 120V, IPH. CIRCUIT AS INDICATED. f PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN CONCEALED ' _ LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN. SIGN FURNISHED BY TENANT. COORDINATE EXACT LOCATIONS WITH TENANT'S CONSTRUCTION MANAGER. J -BOX WILL BE MOUNTED AT 10' -0' AFF- $ MOUNT DUCT SMOKE DETECTOR IN RETURN AIR DUCT IN ACCORDANCE WITH LOCAL CODES. PROVIDE A RELAY TO SHUT DOWN HVAC EQUIPMENT UPON ACTIVATION OF DUCT DETECTOR OR FIRE ALARM (IF PRESENT). CONNECT DUCT DETECTOR TO FIRE ALARM SYSTEM (IF PRESENT). 5 MOTOR OPARETED DAMPER (MOD), 120 VOLT, 1F H. FRAC. HP.. MAKE 120V., 1P14., POWER CONNECTION TO LOCAL CIRCUIT 8 -16 ZONE DAMPER (ZD -1): 120 VOLT FRACTIONAL H.P. MAKE 120 VOLT, POWER CONNECTION TO CIRCUIT 5-16. RUN 1/2' EMPTY CONDUIT (WITH PULL WIRE) BETWEEN ZD AND TI- IER1OSTAT PER MECHANICAL CONTRACTOR REQUIREMENTS. DEVICES AND ALL ASSOCIATED LOW VOLTAGE WIRE CONNECTIONS ARE BY MECHANICAL CONTRACTOR FIELD VERIFY EXACT INSTALLATION AND MOUNTING HEIGHT REQUIREMENTS INCLUDE IN 6ID THE COST FOR A COMPLETE OPERATIONAL FIRE ALARM SYSTEM. 0 THIS SYSTEM SHALL INCLUDE, BUT NOT BE LIMITED TO, AUDIOVISUAL DEVICES, PULL STATIONS, DUCT DETECTORS, CEILING SMOKE DETECTORS, FLOW SWITCH AND TAMPER SWITCH. A LICENSED FIRE ALARM CONTRACTOR SHALL PREPARE AND SUBMIT, TO THE LANDLORD FOR APPROVAL, A COMPLETE FIRE ALARM SYSTEM DRAWING AND MATERIALS LIST, PRIOR TO COMMENCING ANY WORK.. COMPUTER MODEM PHONE LINE QUADRAPLEX RECEPTACL SCE: REFER TO MECHANICAL PLAN FOR LOCATION OF MECHANICAL EQUIPMENT. FIELD VERIFY EXACT LOCATIONS. 2. PROVIDE AND INSTALL AT PANELS DIRECTORY WITH ALL CIRCUITS ACCURATELY DESCRIBED PRIOR TO STORE OPENING. 3. ALL RECEPTACLES AND SWITCH PLATES IN SALES AND NON -SALES AREAS TO MATCH WALL OR CEILING FINISH UNLESS DIRECTED OTHERWISE. TYPICAL MOUNTING HEIGHT IS 18' APP. EXCEPT AT COUNTERS OR IF DIRECTED OTHERWISE. 4. ALL CONDUITS 51-1ALL BE CONCEALED IN WALLS AND OUTLET BOXES SHALL BE FLUSH WITH FINISHED WALL UNLESS OTHERWISE NOTED. 5. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH NATIONAL ELECTRIC CODE AND ALL LOCAL CODES AND ORDINANCES AND LANDLORD'S TENANT DESIGN CRITERIA. POWER AT TRAINING COUNTER 1' 1' 1" 1' 1' I" DATA CO. TEL. CONDUIT ISOLATED GROUND CIRCUIT CONDUIT UTILITY POWER CONDUIT SCALE: N.T.S. GENERAL POWER NOTES DESIGN DRAWINGS ARE SCHEMATIC. VISIT TI-IE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN 1415 BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES. INCLUDED IN 5ID5, THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, T1-1E PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT SHOWN TO REMAIN IS FULLY REMOVED AND NOT 45ANDONED. TYP. CONDUIT STU - UP 6 CAS1 -IW AP � FIELD VERIFY ALL CONDITIONS NO. REVISIONS DESCRIPTION DATE RECEIVED CITY OF TUKWILA NOV 0 5 2008 PERMIT CENTER SHEET NUMBER POWER PLAN E1.0 DATE: 10-30-08 JOB NO: 0813130 DRAWN: CHECKED: GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. TO A-20 13ORINI= 1--- A -12 Emphasis On Excellence M • Retail Engineering, Inc, 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 lie RORINE >3OR INF BO[) INE MEANS OF EGRESS ILLUMINATION IBC 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied, IBC 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot - candle at the walking level. IBC 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways,. 3. Exterior egress components... 4. Interior exit discharge elements... _5. Exterior Iandings...for exit discharge doorways,.. STORE NO. Champs: 14498 NJV 0 3 2` 3 LIGHTING PLAN FURNISH AND INSTALL CONDUIT AND PULL WIRE TO ALL A/V LOCATIONS AS REQUIRED BY A/V VENDOR. CONFIRM REQUIREMENTS AND LOCATIONS WITH OWNER PRIOR TO BIP. SEE DETAIL D/E4.1. WIRE THROUGH A 6 POLE CONTACTOR CONTROLLED i3Y A TIME CLOCK CONTACTOR L`J AND TIME CLOCK SHALL 5E A5 SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. REFER TO SHEET E3.0 AND SPECIFICATIONS FOR MORE INFORMATION. REFER TO ARCHITECTURAL DRAWINGS FOR LIGHTING FIXTURE SCHEDULE HOMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED BY SWITCH 'c'. CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGI -ITING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0. HOMERUN THROUGH A 2 POLE CONTACTOR CONTROLLED BY SWITCH 'd'. CONTACTOR SHALL 8E AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0. 14OMERUN THROUGH A 4 POLE CONTACTOR CONTROLLED BY SWITCH '�'. CONTACTOR SHALL BE AS SPECIFIED IN SPECIFICATIONS AND MOUNTED ADJACENT TO LIGHTING PANEL. SEE MASTER LIGHTING SWITCH BANK DETAIL ON THIS SHEET AND 'POWER RISER' ON SHEET E3.0. DESIGN DRAWINGS ARE SCHEMATIC. VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. REVISIONS DESCRIPTION CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES. INCLUDED IN BIDS, THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES ANI DESIGN INTENT. ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT SHOWN TO REMAIN IS FULLY REMOVED AND NOT ABANDONED. FIELD VERIFY ALL CONDITIONS MASTER LIGHTING SWITCH BANK TO ISE LOCATED AT REAR DOOR TO SALES AREA. SEE DETAIL 'F' ON THIS SHEET. Q CONNECT EMERGENCY, EXIT, AND NIGHT LIGHTING FIXTURES TO CIRCUIT A -22 (TYPICAL). PROVIDE AND INSTALL A SCREW TYPE LOCK -ON DEVICE AT TI-IE CIRCUIT BREAKER. LIGHT F I XTU '.E SCHEDULE I. THE CONTRACTOR FOR THIS WORK 15 REQUIRED TO READ TIE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. 3. GENERAL CONTRACTOR TO INSTALL TENANT FURNISHED CRUSH GUARD SAFETY SLEEVES TO ALL STOCKROOM FLOURESCENT LIGHTING. • LIGHTING ENE '.AL NOTES — 4. SEE ARCHITECTURAL REFLETED FILING PLAN FOR 5. EMERGENCY AND EXIT LIGHTS 5H LL BE INSTALLED AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT BATTERY IBACKUP. ELECTRICAL CONTRACTOR 5 OPERABLE SYSTEM. EXACT LOCATION AND QUANTITY OF LIGHTING FIXTURES. AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE FIXTURES SHALL 5E DUAL VOLTAGE (120/211 VOLT INPUT) WITH MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND SALES AREA SALES AREA SALES AREA ® ® DOWN LIGHTS DOWN LIGHTS TRACK L (GITS RECEIVED CITY OF TUKWILA NOV 0 5 2008 PERMIT CENTER SHEET NUMBER LIGHTING PLAN LIGHTING co 1 EI NOTES MASTER LIGHTING SUJITCk 5,4NK Panel Wiring Schedule (3- Phase) Panelboard Panel Type NEMA Type „A„ NQQD 1 Voltage OCPD Mounting 208Y/120 250A M.C.B. SURFACE Phase 3 Wire 4 Buss 250A Options/Notes AIC Rating 10,000 Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals; Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total ** E Existing Circuit to remain IG Isolated Ground Circuit 24.957 kVA 25.687 kVA 23.991 kVA 74.635 kVA Connected Load: 2072 amps NEC 2005 Demand Feeder Load: 224.4 amps POWER RISE'. AND SCHEDULES Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter Panel Wiring Schedule (3- Phase) Panelboard Panel Type NEMA Type NQOD 1 Voltage OCPD Mounting 208Y/120 M.L.O. SURFACE Phase 3 Wire 4 Buss 100A Options/Notes AIC Rating 10,000 DESCRIPTION N.E.C. CONNECTED kVA Ckt. No. Zone Load Description Brkr. Size Brkr. Opts. N.E.C. kVA ** Phase N.E.C. kVA ** Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 - TRACK LTS 15/1 LO 0.660 A 1.200 Lo 0.000 SIGN 4.100 2 3 4.100. TRACK LTS 15/1 [6] 1.760 0 0.616 Lo [61[71 S.F. LTS 42.988 4 5 [6],[7] TRACK LTS 15/1 Lo 1.760 C 0.750 LO MISCELLANEOUS S.F. TRACK 6 6 7 9 _ SPARE FEEDER AMPERAGE AMPS Lo 0.000 0.000 A B 0.764 LO SALES LTS 8 SPARE 0.822 SALES RECEP. SALES 0.540 8 10 11 SPARE MGR DESK RECEPT. 0.000 C 0.660 SALES RECEP. 0.540 12 0.100 13 SPARE �� 0.000 A 0.654 CASH REGISTER LO SALES LTS A 14 15 SPARE 0.000 B 1.200 ® • SIGN 0.275 16 17 SPARE 20/3 0.000 1.666 C A 0.660 1.508 CASH REGISTER _ _ LO SALES LTS N.S. LTS C 18 20 19 UH -1 21 18 1.667 B 1.142 Lo LO NUEX/EM LTS A 22 23 1.667 0.000 21 ■ SPARE 24 25 B UH -2 20/3 1.667 A 0.000 23 BUZZER/PANIC ALARM SPARE LO 26 27 0.000 1.667 � 0.000 24 SPARE _ 28 29 29 1.666 A • Lo SPARE 30 31 AHU -1 90/3 8.130 �3.740 B 3.715 100/3 SPARE PANEL "B" 28 32 33 SNAKE 8.130 34 35 0.000 8.130 3.730 36 37 30 ACCU -1 70/3 4.968 A 0.000 SPARE 38 39 HACR 4.968 B 0.000 40 41 4.968 C 0.000 _ SPARE 42 Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals; Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total ** E Existing Circuit to remain IG Isolated Ground Circuit 24.957 kVA 25.687 kVA 23.991 kVA 74.635 kVA Connected Load: 2072 amps NEC 2005 Demand Feeder Load: 224.4 amps POWER RISE'. AND SCHEDULES Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, NC & Refrigeration SF Subfeed AFCI Arc Fault Circuit Interrupter Panel Wiring Schedule (3- Phase) Panelboard Panel Type NEMA Type NQOD 1 Voltage OCPD Mounting 208Y/120 M.L.O. SURFACE Phase 3 Wire 4 Buss 100A Options/Notes AIC Rating 10,000 Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total ** E Existing Circuit to remain IG Isolated Ground Circuit Connected Load: 31.0 NEC 2005 Demand Feeder Load: 32.1 3.740 3.715 3.730 11.185 kVA kVA kVA kVA amps amps Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, A/C & Refrigeration SF Subfeed AFCI Are Fault Circuit Interrupter ELECTRIC LOAD SUMMARY 208Y/120V SERVICE DESCRIPTION N.E.C. CONNECTED kVA Ckt. No. Zone Load Description Brkr. Size * Brkr. Opts. N.E.C. kVA ** Phase N.E.C. kVA ** Brkr. Opts. Brkr. Size * Load Description Zone Ckt. No. 1 - S.F. RECEPT. - LO _0.360 A 0.600 1.00 0.000 PRINTER 4.100 2 3 4.100. WC 0.000 [6] 0.600 B 0.000 34.390 [61[71 SPARE 42.988 4 5 [6],[7] VIDEO MONITOR 0.000 Lo 1.050 C 0.165 1.500 MISCELLANEOUS SOUND SYSTEM - 6 7 N.E.C. DEM. KVAX 1000 VIDEO MONITOR FEEDER AMPERAGE AMPS Lo 0.700 A 0.360 LO MGR COMPUTER 8 9 SALES RECEP. 0.540 B 0.360 MGR DESK RECEPT. 10 11 SALES RECEP. 0.540 C 0.100 LO EXIST. PHONE BOARD 12 13 CASH REGISTER LO 0.275 A 0.360 HVAC LTS /REC 14 15 CASH REGISTER LO 0.275 B 1.400 N.S. RECEP. 16 17 CASH REGISTER LO 0.275 C 1.500 WH 18 19 CASH REGISTER LO 0.275 A 0.350 LO VGA MONITOR 20 21 CASH WRAP REC 0.540 B 0.000 SPARE 22 23 BUZZER/PANIC ALARM LO 0.100 C 0.000 SPARE 24 25 TRAINING COMPUTER 0.360 A 0.100 Lo FACP 26 27 SPARE 0.000 B 0.000 SPARE 28 29 SNAKE 0.000 C 0.000 SPARE 30 Notes * All circuit breakers to be 20 -Amp, 1 -Pole unless otherwise noted. All Phases to be balanced to within 10% using Actual Load Totals. N.E.C. Connected Totals: Ph.A N.E.C. Connected Totals: Ph.B N.E.C. Connected Totals: Ph.0 Total ** E Existing Circuit to remain IG Isolated Ground Circuit Connected Load: 31.0 NEC 2005 Demand Feeder Load: 32.1 3.740 3.715 3.730 11.185 kVA kVA kVA kVA amps amps Breaker Options: AS Powerlink AS Breaker LO Handle lock -on device ST Shunt Trip Type AUX Auxiliary Contacts PA Handle Padlock Attachment GFCI Ground Fault Circuit Interrupter HACR Heating, A/C & Refrigeration SF Subfeed AFCI Are Fault Circuit Interrupter ELECTRIC LOAD SUMMARY 208Y/120V SERVICE DESCRIPTION N.E.C. CONNECTED kVA NEC DEMAND NOTES N.E.C. DEMAND FACTOR N.E.C. DEMAND kVA LIGHTING (CONTINUOUS) 14.156 (1] 1.25 17,695 TRACK LIGHT DEMAND ALLOWANCE - [2] - 7.525 SHOW WINDOW DEMAND ALLOWANCE - 13] - 0.693 KIT APPLIANCE 0.000 [4 1.00 0.000 RECEPTACLES 4.100 [5] - 4.100. MOTORS 0.000 [6] . 0.000 FIXED ELECTRIC SPACE HEATING 34.390 [61[71 - 42.988 AIR CONDITIONING SYSTEM 14.904 [6],[7] - 0.000 ELECTRIC WATER HEATER 1.500 - 1.0 1.500 MISCELLANEOUS 5.585 - 1.0 5.585 N.E.C. DEM. KVAX 1000 59.731 FEEDER AMPERAGE AMPS 80.086 = MINIMUM = 222.3 SYS. VOLTAGE X 1.732 80.086 X 1000 208 X 1.732 LOAD SUMMARY NOTES: [1] POWER FACTOR IS ALREADY INCLUDED IN LIGHTING LOAD. [2] 150VAJ2FT OF LINE VOLTAGE TRACK + SUM LOW VOLTAGE XFRMS - CONNECTED LOAD [3] 200VAJLF - ACTUAL CONNECTED LOAD [4] KIT APPLIANCE DEMAND FACTOR PER NEC 220 -56 [5] 0.0 <1 OKW = 100 %, REMAINING - 50% [6] 125% OF THE LARGEST MOTOR OR COMPRESSOR IN SYSTEM APPLIED ON ONE UNIT. [7] USE GREATER VALUE OF THESE TWO CATEGORIES ELECTRICAL CONNECTION SCHEDULE UNIT VOLTAGE FLA MCA MOCP A/POLE GROUNDED AND UNGROUNDED CONDUCTORS CONDUIT SWITCH DISCONNECT AT UNIT CIRCUIT CONNECTION NOTES AHU -1 208V, 3 PHASE 54.2 81 90/3 3 #3 THWN & (1) #8 GND 1 -1/4" 100A, 3 -POLE, NONFUSED A- 31/33/35 ACCU -1 208V, 3 PHASE 41.4 52.6 70/3 3 #4 THWN & 1 #8 GND 1" 100A, 3 -POLE, NONFUSED, WP A- 37/39/41 UH -1 UH 208V, 3 PHASE 13.8 17.3 20/3 3 #12 THWN & 1 #12 GND 3/4" MANUAL MOTOR STARTER A- 19/21/23 -2 208V, 3 PHASE 13.8 17.3 20/3 3 #12 THWN & 1 #12 GND 3/4" MANUAL MOTOR STARTER A- 25/27/29 NOTE: VERIFY EXACT OVER CURRENT PROTECTION /DISCONNECT REQUIREMENTS (PER N.E.C. #440) WITH EQUIPMENT MANUFACTURER NAMEPLATE DATA UPON RECEIPT AT JOB SITE. CONTACT ENGINEER WITH ANY DISCREPANCIES. LEASE LINE LL IS ELECTRICAL CHAMPS SPACE t'324 FURNISH AND INSTALL i4 .280MCM THWN AND I M4 GRID. A D 2 I/2' CONDUIT. TO EXISTING 120/208V., 3101-1, 4W. ELECTRICAL SERVICE. VERIFY A�L� REQUIREMENTS PRIOR TO BIDS Y15UNe Cn PGV � du .fir pub' A1I?'feed v vPM D. c. P T 6 NEW PANEL REFER TO HVAC ELECTRICAL CONNECTION SCHEDULE FOR EXISTING CIRCUITING/WIRE SIZE /CONDUIT SIZE OF HVAC EQUIPMENT. REFER TO SHEET E1.0 AND E2.0 FOR TIME CLOCK CONTROLLED CIRCUITS. EXISTING 7 DAY, 24 HOUR r TTIMECLOCK O CIRCUITS INDICATED ON PLANS. LCJ 120/208V 30 4W -d E l 250A ci M.C.B. I`'I NEW PANEL 120/208V f 30 4W 100A M.L.O. FIELD VERIFY FURNISH AND INSTALL 4 *3 THWN AND 1 .8 GIRD. AND 11/4' CONDUIT. XAC T DISTANCE os I. HVAC CIRCUIT BREAKERS SI -TALL BE 'HACK' TYPE WHERE REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. FIELD VERIFY EXACT A.I.C. RATING OF LANDLORDS DISTRIBUTION EQUIPMENT, FURNISH AND INSTALL TENANTS SYSTEM TO MATCH. 3. BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 10% BETWEEN PHASES: A/B, B /C, A/C REGARDLESS OF CIRCUITING* INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. S. MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM. 6. BOND NEUTRAL TO GROUND AT DISCONNECT SWITCH IF NOT BONDED ON LINE SIDE OF DISCONNECT SWITCH, IF NEUTRAL 15 BONDED ON LINE SIDE OF DISCONNECT SWITCH, DO NOT BOND AT DISCONNECT SWITCH. 1. MAXIMUM LENGTH OF TAP CONDUCTORS ON TRANSFORMER SECONDARY SHALL NOT EXCEED I0' -0' IN LENGTH. 8. PIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. EQUIPMENT NAMEPLATE PER N.E.C. \,_ REVIEWED FOR CODE COMPLIANCE NEC i NFP NOV 13 200 City Of Tukwila BUILDING DIVISION DESIGN DRAWINGS ARE SCHEMATIC. VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. CONTACT THE OWNER PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HIS BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. NAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES. INCLUDED IN BIDS, THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT OWNER OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING CODES AND DESIGN INTENT. ENSURE THAT ALL EQUIPMENT, PIPING AND DUCTWORK, NOT SHOWN TO REMAIN IS FULLY REMOVED AND NOT ABANDONED. POWER RISER GENERAL NOTES RECEIVED CITY OF TUKWILA NOV 0 5 2008 PERMIT CENTER FIELD VERIFY ALL CONDITIONS DATE: 10-30 -08 JOB NO: 0813130 DRAWN: CHECKED: GROSS AREA: 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. Emphasis On Excellence M•Rotail Engineering, Inc. 750 Brooksedge Blvd. Westerville, Ohio 43081 TEL: 614.818.2323 FAX: 614.818.2337 STORE NO. Champs: 14498 2,J 0320:0 yY. 7 3549 le � 4 ISTEr REVISIONS NO. DESCRIPTION DATE SHEET NUMBER ELECTRICAL POWER RISER AND SCHEDULES E3.0 SECONDARY PRIMARY REGISTER REGISTER DATE: 10 -30 -08 JOB N0: 0813130 DRAWN: CHECKED: GROSS AREA 5,535 SQ. FT. SALES AREA: 3,278 SQ. FT. 1 E i L kJ n ki n r* 1 kJ n ri I- 25 Pair 66 Black r i 1 To cash Wrap 5L Lire •�:= ■ C C C— C C C— C C L TO DEMARG -__ — — `-'- — —L — —L • � To Sack Office I 2 ry �r ?r � o f 7. 4),N '� r � 0 E '` 4 2 -, 'r I I- in 0 ice"' „` 'r 161 al- � 0 K - 4 _ 24 I JT the 1 I PFrone —■ _ — — — — — — • CAT 3 Cable AT4T i 2010 (Plenum) 201000045WH ( I ■n A ■ ■■ iE 1 � C — — — — • ., — — — a Y N — w tn Si r cA N w — 4s' r 05 W 1000 (10- 10183SS) • ■ ■ ■ ■ ■�■ 1 • 10 P — — — — ( I E C • rC� "ea'__ , `DSL clp —1 m Cv — ON w m N — • J • n 'I 4 f C— C care �— • kr Emphasis On Excellence M • Retail Engineering, Inc. 750 Brooksedge Blvd. Westerville, OhIo 43081 TEL: 614.818.2323 FAX: 614,818,2337 ■ ■ ■■ ■ ■■ ■.ya ■ ��� c„," — 4, • C— C■ C — _ • • — — — 1 YcmNNn 1 m r 1 m r 3 1 , m r- , el r 3 - u W b — O r r • • = I C ■ f c I- 1 ( ) (Q E C° II II II 1 N w lQ r (A N w BOX PORT) -246 !jl — CO 10 _ _ _ _ III • MANAGER'S ''S 1 ESK L CAIN WRAP SACK OFFICE G,4vN WRAP Surface -Mount Box M104SM , (4 Fort) M1046M5-A -246 (101952442 ) SURFACE -MOUNT M104SM5 (4 M1045M5-A (101952442) A CAIBLE LOCK WIRING DIAGRAM SGT: N.T.S. �'�IONE OUTLET WIRING !DETAIL 1. 2. 3. 1. i• VERIFY WITH TENAT CONSTRUCTION MANAGER THE INSTALL OF THE CAT 3 TIBLES. N TE: DO NOT TERMINATE CABLE NEAR OR ON METAL POLES OR CKS. L SEL JACK AT MANAGER'S DESK AS 'BACK OFFICE JACK'. I STALL A CAT 3 GABLE (SEE PART LIST BELOW FOR PARt NUMBER) F� OM THE CASH WRAP TO THE STORE DEMARG THROUGH DATA NDUIT, AND TERMINATE CABLE AT CASH WRAP PER WIRING DETAIL (F) L BEL JACK AT CASH WRAP AS 'CASH WRAP JACK'. INTAIN A MINIMUM CLEARANCE OF 18 INCHES FROM ALL NOISE E ANATING ELECTRICAL EQUIPMENT (e BALLASTS, POWER FEEDER SLES, ETC.) FOR ENTIRE GABLE RUN. OR CO: �+�v � � 3 Zc3C8 >"ukwil N'"-- �N7 I I� GROMMET IN TOP COUNTER DEDICATED QUAD OUTLET DUPLEX OUTLET FOR PRINTER DETAIL OUT) C F- r TYPICAL WOOD INSTALL IN FIXTURE WOOD LAMINATED MGR. SHELF AND PLUG PROVIDED LIGHT UNDER SHELF. DESK QUAD OUTLET RECEPTACLE _ NI al � CL W NI VOICE LINE I (CASH WRAP BACK OFFICE) DSL ONLY (CASH WRAP ONLY) GM- -� w 0 < kO ,� `# �„ `� 1- ? i ORANGE PAIR BROWN PAIR ,� � n `+ r m E 0 4 FUTURE v / —I V ! ���������������.1 FOR AUDIO SYSTEM. VERIFY EXACT LOCATION WITH A/V 4 3' OF STORE NCB. Champs: 1 �4� - - ►., w to l9 r aD NM ) eP -1 lr 111 " m CM — t' CONTRACTOR, 1-:: . I I -� ci VOICE LINE 2 (CASH WRAP d E3ACK OFFICE) PERFORM AT LEAVE 4/(() A CONTINUITY CHECK FOR EACH CONDUCTOR TERMINATED EACH END OF THE INSTALLED CABLES, INCLUDING CABLE 3HIELD. ONE AS BUILT COPY OF THIS DRAWING WITH STORE MANAGER(S). MANAGER'S DESK i r i 1 r �, ' r PW 3 ac _ _ t ' I SLUE PAIR AI GREEN PAIR l ® E •• OUTLET PIN IIIMPACIPACIAMPIKWIMPFAIR • V) A l4 r- to CAT 3 JACK SURFACE -MOUNT 13OX M104SM5 M1BH -H -246 (4 PORT) M104SMB -A -246 (101321121) 0101952442) 66 'LOCK WIRING DETAIL 25 PAIR 66 BLOCK I till.' 11)2 BUZZER • PHONE (SEE WIRING F FOR ;R aft) GON j _ , g`' '..\�\ 'jytW��35495r• cf• yy�- Wg'�Ji.� J .., h,,4. Am y�,r �/1� ifE- 0/ 11 D GENERAL T 5 5 MANAGER DESK K W I ' I N DETAIL SCE: N.T.S. WIRING DETAIL FOR JACKS. WIRING DETAIL FOR 66 BLOCK EACI -4 JACK IS TO HAVE ONE CA 3 CABLE. CAT 3 CABLE TO CASH WRAP WILL BE TERMINATED FIRST ON !BLUE PAIR ON PINS 4 AND 5 ON JACK IN OUTLET POSITION *I THE 66 BLOCK ORANGE PAIR ON PINS 4 AND 5 ON JACK IN OUTLET POSTION *2 CAT 3 CABLE TO THE SACK OFFICE WILL 113E TERMINATED GREEN PAIR ON PINS 4 AND 5 JACK IN OUTLET POSTION *3 SECOND ON THE 66 BLOCK BROWN PAIR ON PINS 4 A 5 N JACK IN OUTLET POSTION *4 DSL WILL BE BRIDGED TO THE SLUE PAIR ON THE GASH WRAP CABLE ONLY. BLUE PAIR FOR DSL ONLY PHONE LINE WILL BE BRIDGED TO THE ORANGE PAIR ON THE ORANGE PAIR FOR PHONE *I GASH WRAP CABLE. GREEN PAIR FOR PHONE *2 THEN JUMPERED TO THE BACK OFFICE ORANGE PAIR. BROWN PAIR FOR FUTURE IF SECOND PHONE LINE IS REQUIRED IT WILL 1.3E BRIDGED TO THE GREEN PAIR OUTLET COLOR CODE. ON THE CASH WRAP CABLE THEN JUMPERED TO THE SACK BLUE - WHITE PIN 5 ON JACK *1 OFFICE CABLE GREEN PAIR SOLID SLUE PIN 4 ON JACK *1 ORANGE - WHITE PIN 5 ON !JACK *2 66 BLOCK COLOR CODE CASH WRAP CABLE 66 BLOCK SOLID ORANGE PIN 4 ON JACK COLOR CODE BACK OFFICE CABLE GREEN - WHITE PIN 5 ON JACK SOLID GREEN PIN 4 ON JA 4 *3 BLUE - WHITE POSTION BLUE - 111.11TE POSTION 9 BROM - WHITE PIN 5 ON JACK *. SOLID BLUE POSITION 2 SOLID BLUE POSITION 10 WHITE 11 rPRIMARY 1 REGISTER WELL I (I) 3' GROMMET 3' GROMMET HOLE (TYF,) HOLE (TYP.) — — — REVISIONS NO. DESCRIPTION DATE DSL CABLE TO CASH — — — — — -- 1— ISECONDA9- F2EGISTER I F PHONE sorssmaserama REGISTER REGISTER WELL,' WELL 1 WELL I C4) WRAP WIRELESS ACCESS POINT (4684) I 1 (468z) 1 (4684) 0 e (4684) L — — — Imminmmon ♦ - 00 00 [ 0 ® 00 00 +7 ® I • • • SHEET NUMBER MISCELLANEOUS ELECTRICAL DETAILS .. . e .. E4.0 0 / BUZZER ® �® 0 RJ1IC PHONE JACK (LINE 1) CABLE TO B,4GK OFFICE RJ11C PHONE ® JACK (LINE 1) mruitsimil �- SOLID BROWN FIN 4 ON JACK MATERIAL LIST: *4 ORANGE - WHITE POSITION 3 ORANGE - POSITION SOLID ORANGE POSITION 4 SOLID ORANGE POSITION 12 GREEN - WHITE POSTION 5 GREEN - WHITE POSTION 13 SOLID GREEN POSITION 6 SOLID GREEN POSITION 14 BROWN - WHITE POSITION 1 BROWN - WHITE POSITION 15 SOLID BROWN POSITION 8 SOLID BROWN POSITION 16 - FURNISH AND INSTALLFOUR (4) I' CONDUITS TO WRAPPER: ® 1. FOR ENTERNET GABLE 01 FURNISH AND INSTALL ONE NON - DEDICATED DUPLEX OUTLET, WIRED TO PANEL BOAR. 2, FOR TELEPHONE BOARD . 3. FOR GENERAL ELECTRICAL POWER 2 FURNISH AND INSTALL ONE DEDICATED CIRCUIT (SEPERATE HOT, NEUTRAL, 120 VOLT, 20 AMP CIRCUIT WITH QUAD OUTLET 4. FOR DEDICATED ELECTRICAL OUTLETS UNDER EACH WELL, 2 HUBBEL I .*5352 OR APPROPRIATE EQUIVALENT, WIRED TO PANEL BOARD RECEIVED CITY OF TUI \M /� C O t YVI LPI NOV 5 2006 PERMIT CENTER ® - ® [? DESCRIPTION PT PRODUCT MATERIAL ID LENGTH/WIRING SCHEME PACKAGING COLOR SYSTIMAX VOICE CAT LENU`1 3 201000045WH 101018388 3051 (1000 Ft.) WE TOTE WHITE ® M1SN -H-246 10/321121 N/A I /PKt IVORY WIRING MUST BE CLEAN TO HOMERUN WITH OUT ANY CRIMPING AND MUST NOT HAVE ANY ADDITION CONNECTIONS. SYStIMAX DATA CAT 3 OUTLET SYSTIMAX S RFA E MOUNTEDBOX MI04SM5 -A -246 107952442 4 PORTS I /PKCs IVORY WIRING DETAIL SCALES N.T.S. - FOUR CASH REGISTER WIRING IDET4IL SCAI.Et N.T.S. 0 ® ® 4 ® 0 0 ® ® CODED NOTES CAMERA • I FRONT ENTRANCE PUBLIC VIEW (MNI DOME) INTEGRAL DVX00 INSTALL PROCEDURE DATE: ' JOB N O: 081 31 30 CHECKED: GROSS AREA 5,535 Q. PT. SALES AREA: 3,278 SQ. FT. 9 w J «: Z III vg > ` 0 i- T U 0 0 0 0 i - l `) w w = a I- 0 0 z z U U u .1 0 0 0 � u -i W 4 A `� /-,,-\ ADVANCED PUBLIC VIEW (PENDANT MOUNT) I- COLOR CAMERA w/4 -8 rn AIVF LENSCOAX WIRE • 12C I4GA `� • � w WIRE 1 (VERIFY LOCATION ON SITE) W a ! 2 FIXED CAMERA • 2 (MINI DOME) SALES FLOOR MCING THE STORECOLOR CAMERA w14.8.0mm AIVF LENSCOAX WIRE • 2 ? q 2C ISGA WIRE' 2 (VERIFY LOCATION ON SITE) !X U HEADEND NOTES: u N FIXED r41 T g 0 STORE COOR CAMERA w/4-8.0 mm AIVF LENSCOAX WIRE 3 L ALL FIXED POWER IS 2C 18GA NOTED. '' 2. ALL VIDEO CABLE IS RGj59 m ; 2C 18GA WIRE • 3 (VERIFY LOCATION CN SITE) � � o ¢t 8 le `E � /� FIXED CAMERA •4 (MINI DC)h'IE) CAMERA ABOVE REGISTER NOTED. 0 V • 3. THE 110 VOLTAGE BREAKER a. COLOR CAMERA w /4- 8�lnln AIVF LENSCOAX WIRE 4 2C 1 iR 0 18GA WIRE • 4 (VERIFY LOCATION ON SITE) BE cut AT THE ,1 p FIXED CAMERA • 5 (MINI DOME) ENTRANCE TO STOCK 4. NOTE TO INSTALLER - PLEASE 0 `n ® ROOM COLOR CAMERA w/4 -8.0mm AIvF LENSCOAX WIRE • 5 ALLOW SERVICE LOOPS FOR 0 ® 9 ® 2C ISGA WIRE • 5 (VERIFY LOCATION ON SITE) INSTALLATION NOTE: BEFORE USING THIS DOCUMENT, PLEASE WAVE THE INTEGRAL DVX500 HARDWARE 4 SOFTWARE QUICK INSTALL GUIDES AND THE DVXS@0 USER MANUAL READY. ALL PAGE REFERENCES ARE REFERRING TO THE USER MANUAL. I) PLUG IN DEVICES ACCORDING TO CLUCK INSTALL GUIDE (PAGE 6) 2) POWER ON UNIT. PUSH LARGE BUTTON ON FRC)hlT RIGHT -MOST SIDE. (BUTTON ON POWER SUPPLY MUST BE ON 3) LOGIN AFTER UNIT BOOTS, MASTERCONTROL SOFTWARE LOADS AND ASKS FOR USER NAME/PASSWORD. UNLESS OTHERWISE A. CONFIGURE EASYEvIDENCE (PAGE 11) t. SELECT WHICH CAMERAS TO BURN UNLESS OTHERWISE tl. AMOUNT OF TIME TO RECORD TO CD TO 0 PAY, @HOURS, 30 MINUTES 1It. CHECK VIDEO BOOKMARK FEATURE FOR THE EQUIPMENT MUST B. SETUP TAB; (PAGE I6) LECTR CAL FUSE POWER I. SET CAMERA NAMES (PAGE 21) ii. HARDWARE TAB: SET FRAME RATES = 3 IPS IMAGE QUALITY 9 HIGH (PAGE Is) LABEL ALL WIRES AND ' FUTURE SERVICE ON THIS (Ir. USER TAB ADD USERNAME - SERVICE /PASSWORD SERVICE . SELECT ADMIN, APPLY iv. MO oN2tAB: PAINT MASKS ON CAMERAS, SET PERCENTAGE AREA = 125 ,SET SENSITIVITY = FIXED CAMERA • 6 (MINI DOME) ENTRANCE TO STOCK 5. DIGITAL RECORDERS - ALLOW VENTILATION. ALLOW 1/2' PROPER 325 (PAGE 30) EA CE ON ALL SIDES OF v. OUTPUT TAB (FOR EXTERNAL VIDEO DISPLAY MONITOR ONLY (PAGE 31) AFv HairrOR ROOM COLOR CAMERA w /4 -8omm AIVF LENSCOAX WIRE' 6 2C ISGA WIRE • 6 (VERIFY LOCATION ON SITE) THE DIGITAL RECORDER TOP OF THE DIGITAL RECORDS //\ FIXED CAMERA • 1 (MINI DOME) SERVICE DOOR 6. FOR PELCO SEQUENTIAL V COLOR CAMERA w /4 -8.0mm AIVF LENSCOAX WIRE • 1 2C THROUGH - REMOVE LID 18GA WIRE • 1 (VERIFY LOCATION GN SITE) RESISTOR, AND OQ NOT PUT ANYTHING ON 1. OUTPUT ASSIGNMENT DROPDOWN MENU 1'O MANUAL 2. CLICK ON THE CIRCULAR SEQUENCE BUTTC1 ITCHgRS WHEN LOOPING 4D CUT TERMINATION a. REMOVE DEFAULTS b. ADD CAMERAS G. SCHEDULE TAB; (PAGE 58) I. SELECT EVERYDAY DEFAULT. APPLY, ® - - �� 4� :e t W - --, - AXED CAMERA • 8 (MINI DOME) DROP SAFE • .. / COLOR CAMERA w /4 -8.0mm 4IV1 LENSCOAX WIRE 8 2C 24VAC POIUER SUPPLY t1. CHECK 'AUTOMATICALLY RUN THIS SCHEDULE c:N STARTUP' HI. CLICK RECORD BUTTON 5) MONITOR TAB: (PAGE 52) A OUTPUTS TAB: (PAGE 55) I. CLICK 'START TOUR' 6) EXIT MASTERCONTROL Y.. - 18GA WIRE • 8 (VERIFY LOCATION ON SITE) • - ' 9 FIXED CAMERA 9 (MINI DOME) DOOR Q DOLOR CAMERA w /4 -8mm AIVF LENSCOAX WIRE • 9 2C 18GA WIRE • 9 (VERIFY LOCATION ON SITE) _ et - - Emphasis On Ex fence M• Retail Engineering, Inc. 750 Brooksed a Blvd. Westerville, Ohio 43081 TEL 614.818.2323 FAX: 614.818.2337 P to k? '° (2 CHANNEL) 0, C:1 o ® Q �� 1 �1 -- �' ...L._.—.). eL °o °o ® 1) PULL POWER PLUG AND RECONNECT TO VERIFY AUTO-BOOT AND STARTUP IN - -� 24VAC POWER SUPPLY 8) VERIFY ALL CAMERAS ARE ON MONITOR SCREEN AND THE KC IS THE TRAY (PAGE 14) h DEFAULT USERAME = ADMINISTRATOR/PASSUIORD = LET'EN INTEGRAL r 511 VGA MONITOR ID VX500 (2 CHANNEL) /1 IP 1 5 - ......1 00 �/ -J 00 LI SURGE P7TECTOR OD HEADED LAYOUT SGALE : N.T.S. I 120V NOTE: SECURITY WIRING AND CONTACT BY pAT. } TRANSFORMER HEIGHT a 96' App. AND MUST BE CAN! A DEDICATED CIRCUIT CONTROL TRANSFORMER FURNISHED TENANT 13Y VENDOR INSTALLED BY GC. HVAG HVAG EQUIPMENT TERMINAL STRIP Vs < 00 - CONCEALED WIRING t0 DOOR CONTACT BY VENDOR -FLUSH Mtp. KEY SWITCH 'SECURITECH' ALARM FURNISHED AND INSTALLED BY VENDOR �ROOF 24 VOLT CONTROL(A/C) 8 CONDUCTORS, 18AWG GA, SOLID COPPER WIRE,INSULATED WITH CEILING HIGH- DENSITY LLI a. HANG ONLY FROM TOP CHORD L (-- POLYETHYLENECONDUCTOR PARALLEL ENCLOSED IN BROILN PVC JACKET. T -STAT /SENSOR LOCATION. PROVIDE JUNCTION G.G. IS RESPONSIBLE FOR INSTALLATION OF UNISTRUT, THREADED ROD, T.Y. MONITOR TRUSSES AND TV MONITOR RINGS (RINGS ARE SUPPLIED BY AN ' I°' LL _I BOX AT 48' A.F.F. AND 3/4' CONDUIT WITH FULL STRING TO 6' ABOVE FINISHED CEILING. NOTE:THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A SET BACK THERMOSTAT AT 5 FT. ABOVE FINISHED FLOOR COORDINATE EXACT LOCATION WITH ELECTRICAL CONTRACTOR THERMOSTAT 61-IALL BE A 'LIGI-ITSTAT' MODEL THE -AVU, AUTOMATIC SETBACK, 11110 STAGE HEAT, TWO STAGE COOLING THERMOSTAT. (CONTACT'LIGHTSTAT INC.' IN BARICHAMSTED, CT AT 800 -252- 2444) THERMOSTAT SHALL BE FULLY COMPATIBLE WITH HVAG UNIT USED FOR PROJECT, COORDINATE TYPE WITH UNIT MANUFACTURER °' f 1 0� ,. < �.-.1 ELECTRICAL DUPLEX OUTLET MOUNT FASTENED TO UNDERSIDE OF UNISTRUT BLACK OUTLET AND COVERPLATE. LOCATE WITHIN 3' -0' CF MONITOR TM'S, MOUNTS AND STRAPS ARE BY AN VENDOR V d [� ~ L/ 1 1 T L • T 4 f UNISTRUT (SPANS MIN. TWO JOISTS OR AS DIRECTED BY MALL) ►M, TRUSS CEILING MOUNT BY VENDOR ;0---___..- INSTALLED BY GC.<_ 0 I, Silos B - - - f4V,4C UNIT GC 1�1T L S DETAIL N.T.S. STORE Nom. h mIDS: 1 4498 - 4 �`.. J01STS ! = - 1 COLUMN c -° BONE FLANGE v. '• DOCx I FINISHED CEILING 1 9 0 ' 8' _ GC TO FURNISH 4 INSTALL COLLAR TO COVER A.C.T. PENETRATION (TYP) UNISTRUT SUPPORT 0 3/4" SWITCH CONDUIT a: �� �' N „;r 0% r iaE �►1 i I `” 1 \ ;A " I.,� :4 , . \ � � �. 3 LUU ��� , STANCHION MOUNT LIGHT EAGLE #6 4 WITH AN ^1 GUARD EAND H 100W. GLOBE 2D1 EAGLE #604 PORCELAIN w_ /�\ '� �... MONITOR AND MCX�IT ALIGN BOTTOM OF FIXTURE WITH TOP OF RTU. /�� �/ �� EAGLE 4696 METAL.., LAMP 3/4" RIGID 100A -19 LAMP. GALVANIZED STEEL CONDUIT. IF BUILDING STRUCTURE 71-0" DEVICE ABOVE FINISHED CE LING, MOUNTED TO R.T.U. INSTALL JUNCTION BOX SINGLE POLE AND LAMPHOLDER ON n.n \rr1 10 DEGREES -0 AFF• SUPPORT TENANT A/v VENDOR TO MAKE FINAL [�, CONNECTION BETWEEN MONITORS TO WS CV TELEVISION Y ENSURE COMPATIBLE PICTURE DISPLAY SCALE: N.T.S. GFI DUPLEX RECEPTACLE r a' a TOGGLE SWITCH STUB EXTENDED DOWN W /WEATHERPROOF SO LAMPHOLDER IS \D E• GI, CP_ - -- x Ilkg . NOV 3``ti % , � f� 3549 " O`�s" a '� �� r> ' i 07 /11%09 WITH WEATHERPROOF COVER. — COVER NO MORE THAN 7' - -0" fir - ,. ,� •'3 . l - 3/4" RIGID GALVANIZED STEEL CONDUIT. u ROUTE CONDUIT UP ABOVE FINISHED CEILING. THRU RTU FINISHED ROOF SURFACE LEVI ON %,t NT" 5299 -1 COMBINATION SINGLE POLE SWITCH AND NOTE: OUTLET IN SWITCH BOX------" WITH WP COVER ins " NOTE:PROVIpE 120V., I PH. FOR PANIC EXIT DEVICE. THIS SEGURITECH PANIC TENANT'S CONTRACTOR -A POWER SUPPLY FOR ALARM NEEDS TO BE INSTALLED FRAM (ADJACENT TO THE PANIC BAR). CALL 'SECURITECH' TECHNICAL SERVICE INFORMATION. ® pEVIGETO BE INSTALLED BY THE ADJACENT TO THE DOOR AT 80@/624.5282 FOR ANY COORDINATE EXACT LOCATION OF RECEPTACLE AND LIGHT WITH MECH. CONTR. LOCATED BY CEILING ACCESS PANEL AIR DEVICE. SO AS NOT TO BLOCK ACCESS PANELS. / ACCU LIGHT/RECEPTACLE AHU LIGHT/RECEPTACLE �� I 3 4 CONDlJ1T TO 120 / VOLT CIRCUIT. SEE FLOOR PLANS FOR CIRCUIT NUMBER. PANIC DOOR EXIT DEVICE SCALE: N.T.S. e4 C CTV SECTION p E T4 IL WALE: N.T.S. 1-IVAC L IG1- 1T/IRECEFT4CLE Wes: N.T.S. REVISIONS 0 (RJIIC /LINE U CAN-WRAP (RAC /LINE ((RAC /LINE 1) (SALE'S AREA) NET GAT(: BOX 51' 5F 5I'' NO. DESCRIPTION DATE RJ -45 MODULAR MODULAR CONNE TOR CONNECTOR GE IL INCs 1 - - -- -- - - 4, TERMINAL_ LOCK ALARM SYSTEM PANEL (IF REQUIRED) SPEKER CONDUCTOR PLENUM RATED • 16 GA 2- CONDUCTOR, BLACK SOLID COFFER WIRE, PROVIDE JUNCTION Box AT 4s' APP. AND 3/4' CONDUIT ' U)ITH FULL STRING TO ABOVE FINISHED CEILING. TUJISTE D PAIR PIN• SIGNAL. PIN* SIGNAL ■ 1 I TD+ I TD+ (R) -45 (MALE)) (MANAGER'S) I 2 T �� 2 TD- ®(RJIIC /LINE I) (SALE'S AREA) 2 3 ' + 3 RD+ MANAGER'S DESK MODEM, FAX PH ONE (SALE'S AREA) CASHLURAP 3 4 NOT USED 4 NOT USED (SALE'S AREA) GABLE'S SENT ARE TERMINATES %', USE ONLY AS A REFERENCE , IF CABLE ENDS ARE REMOVED al? f (MANAGER'S) i CJ ' F S ' (MANAGER'S) (SALE'S S AREA) NOTE;TENANT C. TO FURNISH AND INSTALL CONDUIT AND PULL WIRE TO ALL AN LOCATIONS AS REQUIRED BY AN VENDOR CONFIRM REQUIREMENTS AND LOCATIONS WITH OU.NER PRIOR TO BID. 3 5 NOT USED B NOT USED 2 4 6 7 ice- NOT US 4D 1 B RD- NOT USED 4 8 NOT USErD S NOT USED - - - Cop p NOTES CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING I' TELEPHONE CONDUIT FROM TENANT'S TELEPHONE SERVICE OBTAIN TELEPHONE SERVICE FROM LANDLORD'S TELEPHONE RUN I' EMPTY CONDUIT WITH PULL WIRE INTO WALL, ETC. 1 0 2' X 3' X 3/4' TELEPHONE BOARD WITH DEDICATED DOUBLE DUPLEX RECEPTACLE AND AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE COMPANY. REUSE EXISTING LOCATION(STOCK RI.) TO TELEPHONE CLOSET. VERIFY EXACT LOCATION IN FIELD. DISTRIBUTION CLOSET. 2® GRD TO BUILDING STEEL OR COLD WATER PIPE PER N.E.G. �3 TELEPHONE OUTLET (VOICE). USE 4' SQUARE JUNCTIC)N SOX WITH PHONE JACK AND GOVERPLATE. up WALL TO STRUCTURE ABOVE, BACK TO TELEPHONE BOARD. SUMMARY OF TELEPHONE LINE REQUIREMENTS- 6 J - 4 PLUG i)IINC IA GRAM ( AU 10 E I A I L. WALE: N.T.S. M SHEET NUMBER 1 C E L LAN E 0 U ELECTRICAL DETAILS TRANSFORMER SIDE OFR£�AR DELIVERY DOOR (EDW 5 0590) 120V BUZZER BELOW DESK DESK RDS •125) MANAGER'S DESK (MANAGERS AREA) BUZZER At STOCK DOOR COMMON (EDWARDS •125) (STOCK AREA) - - I. INSTALL AN ETHERNET CABLE (TWISTED SHIELDED CABLE) FROM THE 5. MAINTAIN A MINIMUM CLEARANCE OF IS INCHES L -'ROh1 ALL NOISE EMANATING MANAGER'S DESK TO THE SALES AREA FLOOR ABOVE STOCKROOM ENTRANCE ELECTRICAL EQUIPMENT (e.r4. BALLASTS, POWER FEEDER CABLES, ETC) FOR ENTIRE DOOR, TYPICALLY BELOW OR ABOVE THE EXIT SIGN. GABLE RUN. NOTE: DO NOT TERMINATE CABLE NEAR OR ON METAL POLES OR RACKS. 6. PERFORM A CONTINUITY CHECK FOR EACH CONDUCTOR TERMINATED AT EACH END OF THE INSTALLED CABLES, INCLUDING CABLE SHIELD. 2. LABLE CABLE .4T MANAGER'S DESK AS 'ACCESS POINT'. RECEIVED 1. LEAVE ONE AS BUILT COPY OF THIS DRAWING WITH STORE MANAG1 =Rls). ClN OP TUI WiL�+ 3. INSTALL GABLE LEAVING ANT AND ALL SLACK COIL IN MANAGER'S AREA 8. INSTALL (2) SCREWS TO EE USED TO HANG THE ACCESS PONT. THE HEAD OF THE NOV 0 5 2008 4. MATERIALS TO BE SUPPLIED DY FOOT LOCKER. SCREWS MAY NOT TO EXC:EEP 1/4' IN DIAMETER THERE MUST BE A MINIMUM GLEARANcE OF 8' PER AlT CENTER (1) LINE REQUIRED AT BACKWRAP FOR HANDSET (1) DEDICATED PHONE LINE AT CASRURAP FOR CREDIT VERIFICATION, EQUIPMENT, MODEM, 4 CAT -3 CABLE IN DATA CONDUIT WITH PULL WIRE. � 0 TELEPHONE CABLE TO BE IN 3/4' CONDUIT WITH PULL WIRE. � - - - - -- - - E4.1 PUSH BUTTON AT REAR DELIVERY BuzzER ABOVE ACT. $ DOOR (EDWARDS N186G -6) (EDWARDS *125) CASH REGISTER (SALES AREA) TELEPHONE RISER » I AC 41 WALE: N.T.S. Q REAR DOOR ZZE '(STEM SCALE= N.T.S. GENERAL E 'r4L NOTE S