Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-1418 - OLD SPAGHETTI FACTORY
OLD SPAGHETTI FACTORY 17100 SOUTHCENTER PY SUITE 160 EL08 -1418 CitAlf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1418 Issue Date: 01/20/2009 Permit Expires On: 11/02/2009 Tenant: Name: OLD SPAGHETTI FACTORY Address: 17100 SOUTHCENTER PY SUITE 160 , TUKWILA WA Owner: Name: WIG PROPERTIES LLC -SS Phone: Address: 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: BOB MARTIN Phone: 503 -225 -0433 Address: 0715 SW BANCROFT ST , PORTLAND OR Contractor: Name: R MARTIN ELECTRIC INC Phone: 425 742 -0852 Address: 3615 132 ST SW, STE A , LYNNWOOD WA Contractor License No: RMARTEI083O5 Expiration Date: 09/25/2010 DESCRIPTION OF WORK: INSTALL 4 SUBPANELS, ALL CONDUIT & WIRE RUN PER PLANS. PROVIDE AND INSTALL LIGHT FIXTURES. INSTALL OWNER PROVIDED FIXTURES, CONNECT ALL EQUIPMENT & START UP REVISION INCLUDES MODIFYING ORGINAL DESIGN TO ADD (1) 200 AMP 120/208 V 3 PHASE PANEL, FEEDER AT TENANT SPACE, AND NEW 200 AMP MODULAR METER STACK AT EXISTING METER CENTER. Value of Electrical: 100,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $1,993.50 2005 Date: &—D-CT-0/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wor I m authorized to sign and obtain this electrical permit. Signature: / /rrri Date: �---2?'4) 9 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended doc: EL -4/07 EL08 -1418 Printed: 05 -29 -2009 or abandoned for a period of 180 days fro milp last inspection. • doc: EL -4/07 EL08 -1418 Printed: 05 -29 -2009 City* Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049081 Address: 17100 SOUTHCENTER PY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -1418 Issue Date: 01/20/2009 Permit Expires On: 07/19/2009 Tenant: Name: OLD SPAGHETTI FACTORY Address: 17100 SOUTHCENTER PY SUITE 160 , TUKWILA WA Owner: Name: WIG PROPERTIES LLC -SS Phone: Address: 4811 134TH PL SE , BELLEVUE WA Contact Person: Name: BOB MARTIN Phone: 503 - 225 -0433 Address: 0715 SW BANCROFT ST , PORTLAND OR Contractor: Name: R MARTIN ELECTRIC INC Phone: 425 742 -0852 Address: 3615 132 ST SW, STE A , LYNNWOOD WA Contractor License No: RMARTEI083O5 Expiration Date: 09/25/2010 DESCRIPTION OF WORK: INSTALL 4 SUBPANELS, ALL CONDUIT & WIRE RUN PER PLANS. PROVIDE AND INSTALL LIGHT FIXTURES. INSTALL OWNER PROVIDED FIXTURES, CONNECT ALL EQUIPMENT & START UP Value of Electrical: 100,000.00 Fees Collected: $1,935.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied vd*th, The granting of this pe construction or the Signature: Print Nam Date: Ot! 2O ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. 't does not • res e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this electrical permit. Ac ��n// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -1418 Printed: 01 -20 -2009 Parcel No.: 2623049081 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW OLD SPAGHETTI FACTORY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -1418 ISSUED 11/06/2008 01/20/2009 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: -7 Date: Q/ Print Nam � �/ ' 2.44/ doc: Cond -Elec EL08 -1418 Printed: 01 -20 -2009 • • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit:No. .KLOO "'' 1.4 .# e Project No. 5? (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: /7/00 ,CfT7 Ce,14/ P CB Suite Number: 670 Tenant Nam /d� C�77 /C New Tenant: IYes ❑ ..No King Co Assessor's Tax No.: 219,130L'1— ?OS Floor: $N% - x4tm-rv-7,l-L 2)t.) C. Property Owners Name: Wi6 peoe6,riFs .L -e Mailing Address: g// /3V 771 /9% ce se- City gib Zip CONTACT PERSON - WBp do we contact. when 'your permit is ready fo be'issued Name: Zoe HA D Mailing Address: 0 Si() FA-A 7 ,� Day Telephone: („4-03) 22-S- •O J 3s n'era APO (,!e7 • 97039 City state Zip E -Mail Address: Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 41 SC /OD/ CC Y� Scope of Work (please provide detailed information): /I — l IfL-s1_r ass s, . 4974.00ir ,` L !__nt Fr Will service be altered? ❑ Yes Oc• Type of Use: Type of work: QilVew ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Adding more than 50 amps? ❑ Yes Property Served by: [Puget Sound Energy ❑ Seattle City Light H:Wpplicadons\Fonns- Applications On Line\4 -2007 - Electrical Permit Application.dec bh ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 i RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN CTRICAL CONTRA deo POW' Signature Print Name: Mailing Address: Q7if J ct-) IDate Application Accepted: I `-_ ..Q i( Day Telephone: /moo re.thv1 City Date: /7.-- c r-Oe? gZip 723�% state Date Application Expires: 5_ (0 -0 1 Staff Initials: H: Applicanons\ Forms - Applications On Line14-2007 - Electrical Permit Appl 'cation. doc bh Page 2 of 2 Parcel No.: 2623049081 Address: Suite No: Applicant: OLD SPAGHETTI FACTORY • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 17100 SOUTHCENTER PY TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -1418 ISSUED 11/06/2008 01/20/2009 Receipt No.: R09 -00800 Initials: WER User ID: 1655 Payee: Payment Amount: Payment Date: Balance: $58.00 05/29/2009 01:31 PM $0.00 R MARTIN ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check Authorization No. ACCOUNT ITEM LIST: Description 1546 58.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 doc: Receiot -06 Printed: 05 -29 -2009 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: EL08 -1418 Address: 17100 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 11/06/2008 Applicant: OLD SPAGHETTI FACTORY Issue Date: Receipt No.: R09 -00047 Payment Amount: $1,560.00 Initials: WER Payment Date: 01/09/2009 03:31 PM User ID: 1166 Balance: $0.00 Payee: OSF INTERNATIONAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1315 1,560.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,560.00 Total: $1,560.00 doc: Receipt-06 Printed: 01 -09 -2009 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 2623049081 Permit Number: EL08 -1418 Address: 17100 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 11/06/2008 Applicant: OLD SPAGHETTI FACTORY Issue Date: Receipt No.: R08 -03702 Payment Amount: $375.50 Initials: WER Payment Date: 11/06/2008 02:49 PM User ID: 1655 Balance: $1,502.00 Payee: OSF INTERNATIONAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1314 375.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 375.50 Total: $375.50 doc: Receiot -06 Printed: 11 -06 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit E oy-1L1i PERMIT NO. Ie-s (206)431 -3670 Project: 5 ^Aa - Type of Inspection: ,2100 Address '� � ��. C.. Date Called: �+ Special Instructions: Date Wanted: D6 /Zc. c4,...11 Requester: Phone No: %Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: OIL/ Date: Exa 5107 O t 0 $60.00 REVNSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT O. CITY OF TUKWILA BUILDING DIVISION IL W 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: SPA. cittcr_ Type of Inspection: 7� `, Add ress: 1710 6.e.. pi Date Called: Special Instructions: Date Wanted: 0(12 1 a:m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - .SerohL,'- /DoE rp65 riirec BkSE Inspector: Date:06 tvi o7 In $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 INSPECTION RECORDg_ l`� l a Retain a copy with permit P a INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Vv.— 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -46 0 Project: ,--)pok . rAc...,-. Type of Inspection: v Address: :7/ao S {�� �" Date Called: Special Instructions: Date Wanted: F��g /// a.m p.m. Requester: / / / Phone No: IDApproved per applicable codes. Corrections required prior to approval. COMMENTS: pa O KEcoaDwci rjeref JITS - '?-o (dS TV4 . F6ePeig, Inspector: Jr fr`'�• Date: Otoftg/D7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1(2- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 6018-11()? Project: �p ��Q,� ../f • CAC/T. ' a, Type of Inspection: 02,00 V Address: /31'00 5•e• • Date Called: OK' - Kra E??tPn &nli -� Special Instructions: Date Wanted: �/r Q 4:? Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: a, 0-K - Ec.E 1ATc per - GIuNkT I\ rtAo-o4e Root f - EJ /p -'roA, 31t dr -ri2I P orb: L4 L5 RteoiceD. l 4 b IC re $elo R(4 P410, 9 43RC- W tk OA tt. VA-To R Al5Conlnl(Gr MD " c L)kTbR CAB 1-141,11? OK' - Kra E??tPn &nli 5 elsIO/ /A LOCK Inspector: 15641461 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: ail/ Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 ►S Project: SPA • 1 J �1 • Type of Inspection: Address: (�h� S r A� Date Called: Special Instructions: Date Wanted: t totq t i aim p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: P 66\W 60.00 REIN PECTION FEE REQ Date: VD/tt Q to inspection, fee El $60.00 IRED. Prior p ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit adS- HI PERMIT NO. CITY OF TUKWILA BUILDING DIVISION YEs 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 Project: 45p Type of Inspection: 7o3 0 `. Address:, (Too oo 5.c, fit , Date Called: Special Instructions: Date Wanted: 06/ I Requester: Phone No: til Approved per applicable codes. 0 Corrections required prior to approval. /2 COMMENTS: O_K. - &ho tfj ' KIT-6451 alLiNiti 116/A-Tok L0813 Inspector: Date: ow 9 ii/0 ❑ $60.00 REINSI'ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: INSPECTION RECORD Retain a copy with permit INSPEt=TION N0. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -36 Project: DNA, Type of Inspection: Address: rpoo s-rticAeif. Date Called: Special Instructions: Date Wanted: 0�°. (.7n. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Pa 4coQp,Ncti n llrtic Inspector: 60■14 ri $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 06 /07/07 Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 641 titl Project: ..- 11 Type of Inspection: 7003 Address: /7/ 00 s.c. Py Date Called: Special Instructions: 11411d Date Wanted: D� Q a.m. P.m Requester: Phone No: DApproved per applicable codes. D Corrections required prior to approval. I COMMENTS: OK. e 6otk at0J45 O. 1. Erckrr Inspector: 'j jJGN S / N r� J /� Date: 06030 EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 11 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 (tog-v.1N Project: f Type of Inspection: 7002_ On/ Wtsw BP-A-4(4 1260 Amp 805 Address:17-100 s• c-• r n Date Called: Special Instructions: Date Wanted: 05 a �m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: /0 - irj 4-Coi)lJ(1 :c Rtail On/ Wtsw BP-A-4(4 1260 Amp 805 8(4IF00 . Ci Jt c e A PPf?j JA t- OF f j 1-n 04 Z - Gam( nl✓rt PAGE Inspector: J$J Date: 1 ri $60.00 REINSP CTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: /0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 14" ELOS-1445 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proat2TA(airTri r rq Type of Inspection: I C ; /Li N6 CoOz Address: 17100 �� PI Date Called: 6/.4(0 Special Instructions: Date Wante�� a.m. p.m. Requests : `RicK-M4gT1ti Phone 425/74-e-0362,- ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: CA'g‘ c;sdC4 - rAi Inspector: &-rkle(S, Date: OS 21 ai ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (2c )431 -3670 614- ri Project: 5p004 �/ Type of Inspection: DD3 Address: . . pl. 1-7100 5 c Date Called: Special Instructions: Date Wanted: D� 049 049 a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Og - CoJef\ nun �JQ,.✓, kintAiPtnii RMS. Inspector: di....6644 Date: D5 f U%v b' to inspection, fe m $60.00 REINS ECTION FEE REQUIRED. Prior p dst be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1.g• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 aof. 114 Project: Type of Inspection: 7oo,3 Address: 11100S.C,, p.i Date Called: Special Instructions: Date Wanted: 05,1i � p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 2A D . K. - covc -K soFirr, a41, 0Jer Roorti,JA uJEST o SiQ� poo� Inspector: Date: O� /O'1f/'04 EIS El toins $60.00 REIN FEE REQUIRED. Prior p a tion f e u st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. g- (206)431-3670 Project: 5+ A"l • -1• Type of Inspection: ��� Address: Mon s .c. Pi - Date Called: Special Instructions: Date Wanted: L� �J c Q / p.m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ?,4 _ 62.11c.E5 Woo AG#D, Inspector: ill 6cw-d Date: 05OY o r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, f e trt 'ust be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Sr_ ainl INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project:5 *l ( e1 ' Type of Inspection: 70 Address: TOO „S.C. P`f Date Called: �- Special In tructions: Date Wanted: 0 ` +v /y j a:m: Requester: Phone No: 0 Approved per applicable codes. 11 Corrections required prior to approval. COMMENTS: CD UG— -)1 14 4 -A Date: b to ins ec ion, m ri $60.00 REINS'ECTION FEE REQUIRED. Prior p y1st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: I.._ . __ ---- �- - - -- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 E�og -rgig 1� Project: Type of Inspection: 7,03 Yfr Address/710 5.c. Date Called: v i} / KDrat S ecial Instructions: p Date Wanted: � rrn p.m. Requester: Phone No: Approved per applicable codes. LICorrections required prior to approval. f COMMENTS: Yfr OK- v i} / KDrat wtt-w5 l 41 Q )c1 r oori, LAJ4+4., E ikS T 5 Df or Dook LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD 6-6" 1 if Retain a copy with permit INSP CTION NO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ft- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (706)431 -3 7 Project: ��' ����� Type of Inspection: 790, Addres11 ` ` S ' C • Pi 1 �Q . Date Called: ---� Special Instructions: Date Wanted: O� %2 (/ a:m Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: O.K Co ✓b,, nEZ.Z, 4otrT4 E JA-414/ 7.00111 1 -4A- -a LAO top LA/65r poil.545 604d Date: q o ZZ10 'f ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee m st be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .Afavrous.sol. • rM•w - -.!!� - �`ti Rr� ' +� . .sue n5 • •,. ,m00 —... . INSPECTION RECORD [1°5 L? PERMIT NO. Retain a copy with permit I ECTION NO. CITY OF TUKWILA BUILDING DIVISION - Blvd. #100, WA 98188 (206)431 -36(0 6300 Southcenter , Project: 1)io SP/A • F4C-TD411 F - Type of Inspection: 706 t Address I1 1°° PI . Date Called: . --- Special Instructions: Date Wanted: V 7 a.rr .:... p.m. Requester: ((( Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ‘41 D 1.440 eMfi UopLID5 01,1 HEZZq.Josle Date: 01/17/07 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit OA= Iti i� PERMIT NO. (206)431 -3670 Project: 5 ��� f Type of Inspection: 700/ Address: 1710o S ' C . Oa • Date Called: Special Instructions: Date Wanted: oy /Qz a .m. Requester: ++ Phone No: xiApproved per applicable codes. El Corrections required prior to approval. COMMENTS: OS. - uNipK51}44> co4pw7 Inspector: `,(r .�' 6tisidtit � $60.00 REINSPECTION FEE RE Date: oy U 2 bl El $ UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: -,:. • .ate INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO.' CITY OF TUKWILA BUILDING DIVISION 1/-' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: I , Type of Inspection: Address: r41.0 Date Called: J J E1111 Special Instructions: Date Wanted: Q��V / a.rry { -p:'m. Requester: ILA' 1 -V k A� ,( (� Phone No: (701-2 .11,,1) 2tl° Approved per applicable codes. Corrections required prior to approval. COMMENTS: P4 - T2E�Ju4 t T I o P\ Dit‘IfAit,k 4e64. 141046 Inspector: *7 &i U $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Date: 03/30/07 Receipt No.: Date: CITY OF TUKVVILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form ilnterier fLightingi Summary; 2008 Washington State Nonresidential Energy Code Compliance Forms LTG -1 N T. Project Info Project Address di- a S a AG IA uzrr1 w► a lC) •-r J. %A,J-r 1114ra 68v714 GeVflvm. 1/1 All LwAM Applicant Name: OFF vi � -►...� 0.1—) o Revised July 2007 Applicant Address: S Z S ii 11•04 -,-)5' to l': Pawn-P.-10 GIL 112 Applicant Phone: Sol 2u -3tt 1 Project Description 'Compliance Option Date t-5--0 For Building Department Use ❑ New Building ❑ Addition J Alteration ttPlans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Alteration Exceptions (check appropriate box - sec. 1132.3) IO Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) ❑ No changes are being made to the lighting i ❑ Less than 60% of the fixtures new, Installed wattage-not Increased, & space use not changed. A Maximum Allowed Lighting Wattage VA Location (floor /room no.) 1 Occupancy Description Allowed Watts per ft2 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Location (floor /room no.) Area in ft2 Allowed x Area Total Allowed Watts t? 21 3 ,ct Fixture Description Number of Fixtures FILE C! PV Watts/ Fixture Watts Proposed Permit Non ?Awl A r4 - —REVIEWED FO CODE COMPLIA� WA 70 - NE! CE► '40V 14 2008 Notes: Total Proposed Watts may not exceed Total Allowed Watts for Interior OW Of Tukwii 13 DING MIS ON Total Proposed Watts IC, • 944 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps In the fixture, and ballast type (if Included). For track lighting, list the length of the track (In feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified In Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as a i the wattage of current limiting devices or of the transformer. tb 81, /tom® 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. �7 IG LOB 1'118 NOV 062008 PERMIT CENTER CITY OF TUKWILA - BUILDING DIVISION 2006 Wasington State Nonresidential Energy Code Compliance Form Interior` Lighting; Summary (back) 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT' Revised July 2007 Prescriptive Spaces Occupancy: Warehouses, storage areas or aircraft storage hangers Other O O QQualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. -1 Unit Llgnting Power Allowance Use' LPAZ (W /sf) Use' LPA2 (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5•''" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia°, assembly spaces° 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition hall'.4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 ootnotes for Tabie 15- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square•footage for a warehouse may be defined, for computing the interior Unit Lighting Power A l ow�r4e, as the floor not Covered by racks plus the vertical face area (access side only) of the racks. The height allowance defin�d _ in foe 2 ap‘lies..onlyikIthe floor area not covered by racks. CITY OF TUKWILA - BUILDING DIVISION 2006 Washington State Nonresidential Energy Code Compliance Form �u Lighting Power Allowance Adjustments • 2008 Washington State Nonresidential Energy Code Compliance Forms Project Address LTGFLPA. Revised July 2007 171 Qo Sa 4.rt-► ce-wrtn. Pim u:4- �► ►� Date II -.s —OS Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Ceiling Height for this room Ceiling Height limit for this exception`* Adjusted LPA Watts per ft2 RECEIVED NOV 08 " From Table 15 -1 based on exceptions listed in footnotes fr'thMIT CENTEF 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting ;Summary Washington State Nonresidential Energy Code Compliance Forms LTG'-INT Ravi Pro) Info Project Address The Old Spaghetti Factory 0..tcSsq ✓vLA,-•T Date 11/3/2008 Southcenter Square For Building Department Use Tukwila, WA Applicant Name: .. rk B. O'Leary Applicant Address: 708 SW • d Avenue, Suite 400 Applicant Phone: Portland, OR 9 Project Description 12143.3 ❑ New Building ❑ Addition 4 Alteration -, Plans Induded Indicate controls (Sections 1513) includin• •mmissioning requirements on plans. Compliance Option O Prescriptive 0 Lighting Power Allowance • Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spac- -arty on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not change.. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area Level 1 Cl, C1A: Downlight, 37W MR16 Restaurant / Bar 1.30 9341.0 12143.3 Mezzanine 24 Restaurant 1.30 2968.0 3858.4 Lobby 26.0 Restaurant (Raised Ceiling) 0.18 453.0 81.5 Bar 222.0 Restaurant (Raised Ceiling) 0.17 262.0 44.5 Banquet Mezzanine Restaurant (Raised Ceiling) 0.18 916.0 164.9 Dining Ll, L2: Table top lamp, 60W Restaurant (Raised Ceiling) 0.35 2632.0 921.2 P1: Pendant 6 195.0 1170.0 Level 1 P2: Pendant 4 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 17213.9 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Level 1, Mez. Cl, C1A: Downlight, 37W MR16 26 37.0 962.0 Level 1, Mez. C2, C2A: Downlight, 20W MR16 24 18.0 432.0 Level 1, Mez. C3: Downlight, 18W CFL 9 26.0 234.0 Mezzanine C4: Wall wash, 37W MR16 6 37.0 222.0 Level 1 C5: Wall wash, 150W T4 8 150.0 1200.0 Mezzanine FM1: Flush Mount, 180W 2 180.0 360.0 Level 1 Ll, L2: Table top lamp, 60W 7 60.0 420.0 Level 1 P1: Pendant 6 195.0 1170.0 Level 1 P2: Pendant 4 252.0 1008.0 Mezzanine P3: Pendant 1 120.0 120.0 Level 1 P4: Pendant 1 108.0 108.0 Level 1 P5: Pendant 5 75.0 375.0 Level 1 P6: Pendant 3 75.0 225.0 Level 1 P7: Pendant 5 160.0 800.0 Level 1 P8: Pendant 1 1500.0 1500.0 Level 1 P9: Pendant 2 300.0 600.0 Mezzanine P10, P13: Pendant 2 100.0 200.0 Mezzanine Pll, P12: Pendant ������ 2 125.0 250.0 Level 1 Sl: Wall sconce NOV 06 2008 6 50.0 300.0 Level 1 32: Wall sconce PERMIT 2 ®ICS cair 125.0 250.0 Level 1 E S3, S5: Wall sconce , 3 50.0 150.0 - • . Mezzanine 54: Wall sconce 2 75.0 150.0 Level 1, Mex. Fl: 2x4 T8 Recessed 40 93.0 3720.0 Level 1, Mex. F2: 2x2 T8 Recessed 6 53.0 318.0 Level 1, Mez. F3: 1x4 T8 Surface 3 62.0 186.0 Level 1 F5: 2x4 T8 Surface 1 93.0 93.0 Level 1, Mez. C6: Monopoint, 37W MR16 43 37.0 1591.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 16944.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. RECEIVED NOV 06 2008 PERMIT CENTE Lighting Power;` Allowance Adjustments 2000 Washington State Nonresidential Energy Code Compliance Forms LTG__ -LPA, Revised July2007 Project Address IThe Old Spaghetti Factory 'Date 11/3/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 main Dining Resteraunt 1.30 22.4 feet 9 feet 1.65 Lobby Resteraunt 1.30 16.0 feet 9 feet 1.48 Bar Resteraunt 1.30 15.7 feet 9 feet 1.47 Banquet Resteraunt 1.30 16.0 feet 9 feet 1.48 From Table 15 -1 based on exceptions listed in footnotes RECEIVE NOV 06 2008 PERMIT CENTEI 2006 Washington State Nonresidential Energy Code Compliance Form :Lighting, Motor,;.jand 2006 Washington State Nonresidential Transformer Permit Plans Checklist' LTG ;CHK Energy Code Compliance Forms Revised July 2007 Project Address The Old Spaghetti Factory Date 11/3/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability • (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controVaccess Schedule with type, indicate locations E2.01, E2.02 yes 1513.2 Area controls Maximum limit per switch E2.01, E2.02 a . a. 1513.3 Daylight zone control Schedule with type and features, indicate locations a . a . vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib/special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w/backup Indicate location yes (b) photocell. Indicate location E0.01 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E2.01, E2.02 yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E2.01, E2.02 E2.11, E2.12 yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning 16915 EXIT SIGNS (Section 1514) yes I 1514 IMax. watts 'Indicate watts for each exit sign I I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture yes 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 I Elec motor efficiency I MECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) n.a. I 1540 ITransformers 'Indicate size and efficiency I If "no" is circled for any question, provide explanation: RECEIVE NOV 0620 PERMIT CENTEI- c,; PERMIT WORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1418 DATE: 05 -18 -09 PROJECT NAME: OLD SPAGHETTI FACTORY SITE ADDRESS: 17100 SOUTHCENTER PY, STE 160 Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 2 After Permit Issued DEPARTMENTS: AV oc-2 Building Division Public Works Fire Prevention UStructural Planning Division Permit Coordinator DETERMINATI N OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05 -19 -09 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: No further Review Required [---/ DATE: APPROVALS O CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-16-09 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1418 DATE: 12 -26 -08 PROJECT NAME: OLD SPAGHETTI FACTORY SITE ADDRESS: 17100 SOUTHCENTER PY, STE 160 Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 11 BEFORE Permit Issued DEPARTMENTS: Zing Io1? Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATIgN OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 12-30-08 Not Applicable U Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS R UTING: Please Route Structural Review Required n REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 01 -27 -09 Not Approved (attach comments) U DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip. doc 2 -28 -02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -1418 DATE: 11 -06 -08 PROJECT NAME: OLD SPAGHETTI FACTORY SITE ADDRESS: 17100 SOUTHCENTER PY SUITE 160 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPART ENTS: Bui g vision Public Works n Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-11-08 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 12 -09 -08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 PROJECT NAME: SITE ADDRESS: n I art ou c24. N • PERMIT NO: Q204?)-- ORIGINAL ISSUE DATE: O(- - pcj REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 V. •t71 _ oi---v. Q� Summary of Revision: r(1,0oLi ' oY i 1 N" d e ci 1- 40 a So( 200 Alex 124 VW V ON c,,n d Summary of Revision: ( (T G J / AA 0 Del S Received by: J '2 AA itytCl Li REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 2- OS•OP - 0`\ Summary of Revision: r(1,0oLi ' oY i 1 N" d e ci 1- 40 a So( 200 Alex 124 VW V ON c,,n d i , (please print) REVISION NO. DATE. RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please Pmt) • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5/5709 Plan Check/Permit Number: ID to Incomplete Letter # ❑ Response to Correction Letter # CrrvilggeTurcwitA ( Revision # after Permit is Issued :EA)/ 18 2009 [11 Revision requested by a City Building Inspector or Plans Examiner RMJJ- CENTER 10g- l41l4i Project Name: r}LD SPI 6 & 11) Project Address: 17100 S6U1.1( (rNTEl'Z phrociA A'J' Contact Person: P)C MA -4-7* Phone Number: 4Z5-7-1.2-08-52_ Summary of Revision: MC)C)rP,/ orl y ►mil jes ac v To ado J 200 lyre 12i /zoto 3 JPU 12nel - (QQ2o' Team q1A ie paw 2a I i p /fOclulaly 4�'kh'r c/a ck r P,i� % 69de✓ (04V ge1p e /oars 5d- edu/e5 .{61/ HVAC Q()V,frnenl vii i014 . l Sheet Number(s): C �oQ2 S'O/, %, d) "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: (45v' 110 Entered in Permits Plus on l till 041 \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: — 2 3 -O Plan Check/Permit Number: ft/V— Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: /ci/ Q e7 ‘y----- Project Address: 7 0 i C"poa[ i _ . / , , �� Contact Person: //-)j %fit-1-(-77nJ Phone Number: '706 - 5a ' c Summary of Revision: ) 2 2 -057 3 C1TV p DEC 2 6 2008 PERMIT CENTER Sheet Number(s): ' 9.O/1 a , U/ 2--Oz 3.0 -O z 3 -03 57 ) / ,0 / "Cloud" or highlight all areas of revision including date of revision / Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications\fonns- applications on line\revision submittal Created: 8 -13 -2004 Revised Untitled Page • Page 1 of 2 Electrical Contractor A business licensed by Lftl to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company R MARTIN ELECTRIC INC 4257420852 3615 132ND ST SW STE A LYNNWOOD WA 980875138 SNOHOMISH CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601252051 ACTIVE RMARTEI08305 ELECTRICAL CONTRACTOR 9/25/1992 9/25/2010 MARTI R *968M0 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License MARTIR*968M0 Name MARTIN, RICK Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MARTIN, JUNE Cancel 01/01/1980 Bond MARTIN, RICK AGENT 01/01/1980 Account MARTIN, RICK PRESIDENT 01/01/1980 Date Bond Information https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= RMARTEI083O5 01/20/2009 Bond Bond Effective Expiration Cancel Impaired Bond Received Bond Company Account Date Date Date Date Amount Date Name Number https: // fortress. wa. gov /lni/bbip/Detail.aspx ?License= RMARTEI083O5 01/20/2009 LUMINAIRE SCHEDULE 11-118 L.0 NAEE x� E 18 NOT COMPLETE WITHOUT A COPY OF THE PROJECT MANUAL CONTAMIG THE ELECTRICAL 8PECFICATIONB. TYPE: C1 DESCRIPTION: HOUSING: LENS: REFLECTOR: MOUNTING: UL LISTING: LAMP: MANUFACTURERS: TYPE: CIA DESCRIPTION: HOUSING: LENS: REFLECTOR: MOUNTING: UL LISTING: NOTE: LAMP: MANUFACTURERS: TYPE: C2 DESCRIPTION: HOUSING: LENS: REFLECTOR: MOUNTING: UL LISTING: LAMP: MANUFACTURERS: TYPE: CM DESCRIPTION: HOUSING: LENS: REFLECTOR: MOUNTING: UL LISTING: NOTE: LAMP: MANUFACTURERS: TYPE: C3 DESCRIPTION: HOUSING: REFLECTOR: BALLAST: LLAMP: MANUFACTURERS: TYPE: C4 DESCRIPTION: HOUSING: LENS: REFLECTOR: MOUNTING: UL LISTING: LAMP: MANUFACTURERS: TYPE, C5 DESCRIPTION: HOUSING: LENS: REFLECTOR: MOUNTING: LAMP: MANUFACTURERS: TYPE Ce DESCRIPTION: HOUSING: LENS: MOUNTING: FINISH: BALLAST: UL LISTING: LAMP: MANUFACTURERS: TYPE: C7 DESCRIPTION: HOUSING: LENS: MOUNTING: FINISH: BALLAST: UL LISTING: LAMP: MANUFACTURERS: TYPE: Fl DESCRIPTION: HOUSING: LENS: BALLAST: LAMP: INPUT WATTS: MANUFACTURERS: 4 INCH APERTURE NOMINAL DOWNLIGHT LUMINAIRE STEEL HOUSING PAINTED MATTE BLACK. TOP ACCESSIBLE BROAD SPREAD LENS TYPICAL OF ABRIZA CRYSTAL LOW IRRIDESCENT CLEAR REFLECTOR. NON— ADJUSTABLE DOWNLIGHT TRIM. RECESSED UL LISTED 37 WATTS MAXIMUM OSRAM SYLVANIA 37W IR MR16 NSP COOPER PORTFOLIO HA3MR SERIES OR APPROVED 4 INCH APERTURE NOMINAL ADJUSTABLE DOWNLIGHT LUMINAIRE STEEL HOUSING PAINTED MATTE BLACK. TOP ACCESSIBLE BROAD SPREAD LENS TYPICAL OF ABRIZA CRYSTAL LOW IRRIDESCENT CLEAR REFLECTOR. ADJUSTABLE DOWNLIGHT TRIM. RECESSED UL LISTED 37 WATTS MAXIMUM ORDER WITH 20 DEG CUT ADJUSTABLE TRIM OSRAM SYLVANIA 37W IR MR16 NSP COOPER PORTFOLIO HA3MR SERIES OR APPROVED 4 INCH APERTURE NOMINAL DOWNLIGHT LUMINAIRE STEEL HOUSING PAINTED MATTE BLACK. TOP ACCESSIBLE BROAD SPREAD LENS TYPICAL OF ABRIZA CRYSTAL LOW IRRIDESCENT CLEAR REFLECTOR. NON— ADJUSTABLE DOWNLIGHT TRIM. RECESSED UL LISTED 20 WATTS MAXIMUM OSRAM SYLVANIA 20W IR MR16 NSP COOPER PORTFOLIO HA3MR SERIES OR APPROVED 4 INCH APERTURE NOMINAL ADJUSTABLE DOWNLIGHT LUMINAIRE STEEL HOUSING PAINTED MATTE BLACK. TOP ACCESSIBLE BROAD SPREAD LENS TYPICAL OF ABRIZA CRYSTAL LOW IRRIDESCENT CLEAR REFLECTOR. ADJUSTABLE DOWNLIGHT TRIM. RECESSED UL LISTED 20 WATTS MAXIMUM ORDER WITH 20 DEC CUT ADJUSTABLE TRIM OSRAM SYLVANIA 20W IR MR16 NSP COOPER PORTFOLIO HA3MR SERIES OR APPROVED RECESSED FLUORESCENT DOWNLIGHT. 5" NOMINAL DIAMETER HOUSING. MATTE CLEAR REFLECTOR, SELF FLANGED. ELECTRONIC. ONE CF181TT. GOTHAM LIGHTING AFV SERIES, KURT VERSEN PORTFOLIO, LIGHTOLIER, PEACHTREE OR APPROVED. LENSED WALL WASH LUMINAIRE 4 INCH DIAMETER NOMINAL STEEL HOUSING PAINTED MATTE BLACK. TOP ACCESSIBLE DIFFUSING SPREAD LENS FIXED TO TRIM LOW IRRIDESCENT CLEAR REFLECTOR RECESSED UL LISTED 37 WATTS MAXIMUM . OSRAM SYLVANIA 37W IR MR16 NSP COOPER PORTFOLIO HA3MR SERIES OR APPROVED LENSED WALL WASH LUMINAIRE 7 INCH DIAMETER NOMINAL STEEL HOUSING PAINTED MATTE BLACK. TOP ACCESSIBLE DIFFUSING SPREAD LENS FIXED TO TRIM LOW IRRIDESCENT CLEAR REFLECTOR RECESSED 150W QT4 MINI —CAN HALOGEN COOPER PORTFOLIO HA3MR SERIES OR APPROVED MONOPOINT ADJUSTABLE ACCENT DOWNLIGHT DIECAST ALUMINUM HOUSING SOFT FOCUS LENS TYPICAL OF ABRIZA SOLITE SURFACE MOUNT TO JUNCTION BOX WITH FATORY MONOPOINT ADAPTOR BLACK ELECTRONIC UL LISTED 37 WATTS MAXIMUM OSRAM SYLVANA 37W IR MR16 NSP LIGHTOLIER TRON SERIES OR APPROVED MONOPOINT ADJUSTABLE ACCENT DOWNLIGHT DIECAST ALUMINUM HOUSING SOFT FOCUS LENS TYPICAL OF ABRIZA SOLITE SURFACE MOUNT TO JUNCTION BOX WITH FATORY MONOPOINT ADAPTOR BLACK ELECTRONIC UL LISTED 20 WATTS MAXIMUM OSRAM SYLVANA 20W IR MR16 NSP LIGHTOLIER TRON SERIES OR APPROVED RECESSED FLUORESCENT LENSED TROFFER. 2' BY 4' COLD ROLLED STEEL HOUSING. #12 PATTERN, 0.125" THICK ACRYLIC DIFFUSER. ELECTRONIC. TWO F32T8. 58 LITHONIA SP SERIES, METALUX GC SERIES, DAYBRITE, HUBBELL, COLUMBIA, LIGHTOLIER, HE WILLIAMS OR APPROVED. TYPE: F2 TYPE: F3 TYPE: F5 TYPE: PI TYPE: P2 TYPE P3 TYPE: P4 TYPE: P5 TYPE P6 TYPE P7 TYPE P8 TYPE: P9 TYPE: PIO TYPE P11 TYPE P12 DESCRIPTION: HOUSING: LENS: BALLAST: LAMP: INPUT WATTS: MANUFACTURERS: DESCRIPTION: HOUSING: REFLECTOR: FINISH: BALLAST: NOTE: LAMP: INPUT WATTS: MANUFACTURERS: DESCRIPTION: HOUSING: LENS: MOUNTING: FINISH: BALLAST: LAMP: INPUT WATTS: MANUFACTURERS: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: RECESSED FLUOR 2' BY 2' COLD R #12 PATTEF'!N, 0.1 ELECTRONIC. THREE 17W T8 60W LITHONIA SFl SERI DAYBRITE, UBBE_ WILLIAMS OR APP SCENT LENSED TROFFER. �LLED STEEL HOUSING. 25" THICK ACRYLIC DIFFUSER. MPS. S, METALUX GC SERIES, L, COLUMBIA, LIGHTOLIER, HE OVED. SURFACE M?UNTEII FLUORESCENT INDUSTRIAL. 4' DIE FORMED S EEL CHANNEL. COLD ROLLED STEEL REFLECTOR WITH NO UPLIGHT. WHITE FINIS ELECTRONIC.1 SUITABLE FOR SU "FACE, CHAIN HANG, OR CONDUIT STEM MOUNTING TWO F32T8. 58 LITHONIA AFST SE "IES, METALUX DIM SERIES, DAYBRITE, HUBBE , COLUMBIA, LIGHTOLIER, HE WILLIAMS APPROVED. FLUORESCENT LEN ED TROFFER. /1\ 2' BY 4' COLD R LLED STEEL HOUSING. #12 PATTER 4, 0.1 5" THICK ACRYLIC DIFFUSER. SURFACE M UNTE WHITE ELECTRONIC. TWO F32T8. 58 LITHONIA, METALUX DAYBRITE, HUBBELL, COLUMBIA, LIGHTOLIER, HE WILLIAMS OR APPROVED. CUSTOM PENDANT CUSTOM PENDANT CUSTOM PEN CUSTOM PEN CUSTOM PEN CUSTOM PE CUSTOM PE CUSTOM PE DANT DANT DANT BY OWNER BY OWNER BY OWNER BY OWNER BY OWNER DANT BY OWNER DANT Y OWNER DANT Y OWNER CUSTOM PENDANT Y OWNER CUSTOM PENDANT Y OWNER CUSTOM PENDANT :Y OWNER CUSTOM PENDANT :Y OWNER TYPE 81 TYPE 82 TYPE 83 TYPE 84 TYPE 85 TYPE Li TYPE: L2 TYPE: FM1 DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: DESCRIPTION: CUSTOM SCONCE T OWNER CUSTOM SCONCE OWNER CUSTOM SCONCE OWNER CUSTOM SCONCE OWNER CUSTOM SCONCE B OWNER / 1 \ CUSTOM TABLE LA P BY OWNER CUSTOM TABLE LA P BY OWNER CUSTOM FLUSH TO CEILING BY OWNER TYPE: El TYPE: E2 TYPE E3 TYPE: E4 DESCRIPTION: HOUSING: LENS: MOUNTING: FINISH: BALLAST: UL LISTING: NOTE: MANUFACTURERS: DESCRIPTION: HOUSING: LENS: FINISH: BALLAST: NOTE: LAMP: LAMP: INPUT WATTS: MANUFACTURERS: DESCRIPTION: HOUSING: MOUNTING: FINISH: BALLAST: UL LISTING: NOTE: MANUFACTURERS: DESCRIPTION: HOUSING: MOUNTING: FINISH: BALLAST: UL LISTING: NOTE: MANUFACTURERS: EXTERIOR EM RGENCY LIGHTING UNIT DIE CAST ALL MINUN HOUSING PROVIDE DIFFUSING LENS. SURFACE MOUNT BLACK PROVIDE 90 MINUTE LEAD CALCIUM BATTERY UL924 PROVIDE SEL DIAGNOSTIC. COOPER CHE SERFS OR APPROVED UNIVERSAL MOUNTED L.E.D. EXIT SIGN. HIGH IMPACT THERMOPLASTIC WITH TWO EMERGENCY LIGHTING HEADS PROVIDE DIFFUSING LENS. BLACK PROVIDE 90 MINUTE NICKEL CADIUM BATTERY BACK —UP. PROVIDE SELF DIAG OSTIC. GREEN L.E.D. 6W, 6V HALOGEN E ERGENCY LAMPS 2.3. LITHONIA ELA MR24 H0606 SERIES, COOPER, SURE —LITES HUBBELL, CHLORIDE LSI LIGHTING OR APPROVED. A ARCHITECTURAL EM 'GENCY LIGHTING UNIT DIE CAST ALUMINUM HOUSING SURFACE MOUNT W LL BLACK PROVIDE 90 MINUTE LEAD CALCIUM BATTERY UL924 PROVIDE SELF DIAGNOSTIC. COOPER CHEL SERIES OR APPROVED ARCHITECTURAL EMERGENCY LIGHTING UNIT DIE CAST ALUMINUM HOUSING SURFACE MOUNT CE LING BLACK PROVIDE 90 MINUTE LEAD CALCIUM BATTERY UL924 PROVIDE SELF DIAG OSTIC. COOPER CHEL SERI S OR APPROVED FILE: 0497E0.O1.DWG — E0.01 I EDIT: 12/23/2008 3:20 PM BY QUINLANB I PLOT: 12/23/2008 3 :20 PM BY QUINLAN BELOG ELECTRICAL SYMBOL LIST * This is a standard list and not all symbols and abbreviations may be used. SWITCHES AND RECEPTACLES SINGLE POLE SWITCH Os 3 = THREE —WAY SWITCH 4 = FOUR —WAY SWITCH a THRU z (LOWERCASE) = LUMINAIRE CONTROL DESIGNATION D = DIMMER F = FAN SPEED CONTROL K = KEY OPERATED SWITCH L = LIGHTED HANDLE M = MANUAL MOTOR STARTER WITH THERMAL OVERLOAD P = SWITCH WITH PILOT LIGHT CEILING MOUNTED OCCUPANCY SENSOR P = PASSIVE INFRARED D = DUAL TECHNOLOGY U = ULTRASONIC, 360 DEG RANGE H = ULTRASONIC, HALLWAY PATTERN WALL MOUNTED OCCUPANCY SENSOR P = PASSIVE INFRARED D = DUAL TECHNOLOGY WALL MOUNTED OCCUPANCY SENSOR /SWITCH S = PASSIVE INFRARED WITH INTEGRAL "OFF" SWITCH ® SPECIAL PURPOSE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR OPTIONS 4 EP AFD OR I'I 0 TWISTLOCK RECEPTACLE. COORDINATE RECEPTACLE CONFIGURATION WITH EQUIPMENT BEING SUPPLIED. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR OPTIONS SINGLE RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR OPTIONS DUPLEX RECEPTACLE A = ABOVE COUNTER C = FLUSH CEILING MOUNTED G = GROUND FAULT CIRCUIT INTERRUPTER W = WEATHERPROOF CONTINUOUS USE COVER AND GFCI PROTECTED DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX RECEPTACLE FOR OPTIONS CONNECTIONS EQUIPMENT MOTOR CONNECTION NON —FUSED DISCONNECT SWITCH HEAVY DUTY FUSED DISCONNECT SWITCH COMBINATION ADJUSTABLE FREQUENCY DRIVE WITH SAFETY DISCONNECT SWITCH JUNCTION BOX TRANSFORMER CONTACTOR COIL C SMOKE DUCT DETECTOR, PROVIDED BY DIVISION 15, /1 LOW — VOLTAGE WIRING BY DIVISION 16 a WEATHER PROOF PUSH BUTTON BUZZER, ABOVE CEILING NOTE: COMPONENTS SHOWN IN DEACTIVATED CONTROL POWER STATUS MANUAL OVER —RIDE SW. S.P.S.T. CONTROL POWER VERIFY VOLTAGE 2P1 -42. TELECOMMUNICATIONS TELEPHONE OUTLET WITH 3/4" C. AND PULLSTRING TO ACCESSIBLE CEILING SP V COMBINATION COMMUNICATIONS OUTLET WITH 1 "C. TO ACCESSIBLE CEILING SPACE TELEVISION SIGNAL OUTLET WITH 3/4 "C. TO ACCESSIBLE CEILING SPACE MISCELLANEOUS Q CONDUIT ELLED UP CONDUIT ELLED DOWN CONDUIT /WIRING STUBBED OUT WITH END CAP OR INSULATED PLASTIC BUSHING GROUNDING POINT SURFACE MOUNT EQUIPMENT ENCLOSURE AS NOTED FLUSH MOUNT EQUIPMENT ENCLOSURE AS NOTED BRANCH PANEL FLUSH WALL MOUNTED BRANCH PANEL MAIN DISTRIBUTION PANEL / SUB DISTRIBUTION PANEL FLEXIBLE CONDUIT BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO PANEL WITH CIRCUITS AS NOTED. WIRE SIZE IS #12 AWG MINIMUM UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE CONDUCTORS. LONG TICK MARKS INDICATE NEUTRAL CONDUCTORS. A SINGLE CURVED TICK MARK INDICATES INSULATED GREEN GROUND CONDUCTOR. SECOND CURVED TICK MARK INDICATES "ISOLATED GROUND" (GREEN INSULATION WITH YELLOW STRIPE) CONDUCTOR. CONDUIT CONCEALED IN WALL OR CEILING SPACE CONDUIT ROUTED BELOW FLOOR / GRADE EXISTING CONDUIT CONCEALED IN WALL OR CEILING SPACE EXISTING CONDUIT ROUTED BELOW FLOOR / GRADE REFERENCE NOTE KITCHEN EQUIPMENT CONNECTION ITEM. REFER TO SCHEDULE 0 A AFF AFG AIC AV C CB CATV CLG CU E N __F_ SURFACE MOUNT NEMA 1 ENCLOSURE WITH HINGED COVER. PROVIDE ENGRAVED LABEL TO READ 'LIGHTING CONTROL CABINET'. MECHANICAL EQUIPMENT CONNECTION ITEM. REFER TO SCHEDULE ABBREVIATIONS AMPERES, AMBER ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AVAILABLE INTERRUPTING CAPACITY AUDIO VISUAL CONDUIT, CLOSE, CONTROL CIRCUIT BREAKER CABLE TELEVISION CEILING COPPER EMERGENCY TORK SERIES 2100 PHOTOCELL MOUNT ON ROOF, CLEAR OF OBSTACLES AND ARTIFICIAL LIGHT. AIM NORTH. DIGITAL TIME CLOCK, 24 HOUR, 7 DAY SCHEDULING, TORK SERIES DG100 WITH RESERVE POWER 2P1 -40. F- ---I CONTACTORS: SQUARE D, CLASS 8903 TYPE "L ". EXTERIOR LIGHTS AT DOOR SPARE PHOTOCELL ON TIME CLOCK OFF 1 LIGHTING CONTROL DIAGRAM NO SCALE REVISIONS changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. (E) EXISTING (EM) EMERGENCY LIGHTING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL GFCI GROUND FAULT CIRCUIT INTERRUPTER GFI GROUND FAULT INTERRUPTER G, GND GROUND KV KILOVOLT KVA KILOVOLT AMPERES KW KILOWATT M MOTOR MCA MINIMUM CIRCUIT AMPS MOCP MAXIMUM OVERCURRENT PROTECTION (N) NEW NC NORMALLY CLOSED NL NIGHT LIGHT NO NORMALLY OPEN OSF THE OLD SPAGHETTI FACTORY PH PHASE TTB TELEPHONE TERMINAL BOARD TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR TYP TYPICAL UL UNDERWRITERS LABORATORIES UPS UNINTERRUPTABLE POWER SUPPLY V VOLTS, VOLTAGE W WIRE, WHITE WP WEATHERPROOF SECARAT E PERMIT REQUIRED FOR: lid Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION_. r REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC Fes... FILE COPY Permit 1o. pI r rcvlaw tpprovcl I3 subject to c>froro ofd asra iC ri. E,r proval e1 construction document3 063 r c1 cu!I O!' .a Vic violation cl cm/ adoptad codo cr ordinance. fcce rt o' r pprovad Fl S, . t ; acknot :d cJc tior City of Tukwila ., • CU:LJ o D3VISM11 PRI a 9y c 18 e LL P 2525 East Burnside a Portland, OR 97214 50122413017 phone a 503225.3715 Arx uuu11p.corn THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON -FOS HIS DRAWING INDEX E0.01 COVER SHEET — ELECTRICAL E2.01 FIRST FLOOR PLAN — LIGHTING E2.02 SECOND FLOOR PLAN — LIGHTING E2.11 FIRST FLOOR PLAN — LIGHTING ZONES E2.12 SECOND FLOOR PLAN — LIGHTING ZONES E3.01 FIRST FLOOR PLAN — POWER & SIGNAL E3.02 SECOND FLOOR PLAN — POWER & SIGNAL E3.03 ROOF PLAN — POWER & SIGNAL cr4DESAutiwitAc 2 6 2008 PERMIT CENTER E5.01 ONE LINE DIAGRAM, PANEL SCHEDULES — ELECTRICAL E6.01 DETAILS, CONNECTION SCHEDULES -- ELECTRICAL RV!1ON No. Contact Mark O'Leary Project 2008 -0497 t� INTERFACE E N G I N E E R I N G 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 COVER SHEET ELECTRICAL Job No: 0826 File Name: Date: 12/17/08 Rev: A \ CITY REVIEW COMMENTS Sheet No: E0.01 GENERAL NOTES A. REFER TO ARCHITECTURAL DRAWINGS FOR LUMINAIRE QUANTITIES, LAYOUT AND ADDITIONAL SPECIFICATION. B. CIRCUIT EXIT SIGNS 'E2' AND BUG—EYE 'E4' FIXTURES TO 2P1-38. C. ALL LUMINAIRES WITH (EM) DESIGNATION: PROVIDE ONE LAMP ON EMERGENCY BATTERY BACK—UP WITH A MINIMUM OF 1200 LUMENS. =7" B F C [P1 03 M 21:: 03 03 3 0 .1 1 Th.L. - -41 421C CC F 2 kIT C 2 C2 DOWN / / . r / ,,,,, ,,, [C6 // , . % S // # // .... "" s,.>„ \ `▪ `. .......... NiN▪ / \/ \\Ns, C6 C6 C6 C6 P3 \‘", N. 4. "N. LJ 1)1 C7 F1 F1 C4 P2 CE 2P1-41. #10 FILE: 0497E2.02.DWG E2.02 1 EDIT: 11/21/2008 11: 43 AM BY ANNAS 1 PLOT: 12/23/2008 3: 21 PM BY QUINLAN BELOG ......... ........ T arE C6 E4 L7 P12 04 AN 1 NG 2111 C7 C6 060 C6 C6 EN 0 W F1 P13 06 06 P2 P2 06 06 P1 E3 +22' 06 06 • 04 04 04 02 P1 06 06 C6 P1 1 SECOND FLOOR PLAN - LIGHTING' 0 2' 4' 8' SCALE: 1/4"=1'-0" 1 SHEET KEYNOTES ROUTE VIA DIMMING CONTROL PANEL 'LCP1'. EACH ZONE CORRESPONDS TO A RELAY BRANCH. EACH BRANCH CIRCUIT CORRESPONDS TO A MODULE. EACH MODULE CONTAINS UP TO 4 RELAY BRANCHES A (ZONES), 1800W MAX TOTAL FOR EACH \ MODULE. ....... .. PROVIDE LUTRON OR APPROVED SWITCH FOR SCENE CONTROL OVERRIDE. INCLUDE BUTTONS FOR "HOUSEKEEPING", "LUNCH", "DINNER", AND "OFF". (r) CCRICEOWMEPD --F° RC NFPA 70 - rvEc DEC 3 0 2003 08 14 3 Crril;f1SMtA DEC 2 6 2008 PERMIT CENTER Contact Mark O'Leary Project 2008-0497 INTERFACE mow.iJr"'' ENGINEERING 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PI-IONE 503.382.2266 FAX 503.382.2262 111111111. a r c 11 411111 17 (17tt,.!-re L L P 252f3 Et Burnside Bt. Portland, OR 97214 903.226,3617 ;Mona 503.290.3715 fax seallp.corn THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON SECOND FLOOR PLAN — LIGHTING Job No: 0826 File Name: Date: 12/17/08 Rev: CITY REVIEW COMMENTS Sheet No: E2.02 SWITCH ONLY 1 FIRST FLO O" PLAN - LIGHTING ZONES SCALE: 1 /4 " =1' -0" FILE: 0497E2.11.DWG — E2.11 I EDIT: 11/3/2008 8: 49 AM BY MARKO 1 PLOT: 11/3/2008 8:59 AM BY MARK OLEARY D GENERAL NOTES A. REFER TO ARCHITECTURAL DRAWINGS FOR LUMINAIRE QUANTITIES, LAYOUT AND SPECIFICATION. GQaE COMPLIANCE. EC NON 1 2008 • arelliterture, THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWLA, WASHINGTON FIRST FLOOR PLAN LIGHTING ZONES Job No: 0826 File Name: ELOB1M(8 Date: Contact Mark O'Leary Project 2008 -0497 INTERFACE E N G I N E E R I N G 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 Rev: 10/31/08 RECEIVED NOV 06 zoo i PERMIT CENTEt Sheet No: E2.11 Li 2 . C2 C2 C2 S5 t -_. P11 -. P12 E2 T C2 I t. C2 r" C6 Fe S2 C6 C6 C6 C6 C6 • Fe S2 C6 C6 C6 P2 C6 EN ow C6 LJ C6 C6 • C6 C6 C6 C6 P1 P1 P1 P1 a" N1/ L3 1- L. FILE: 0497E2.12.DWG - E2.12 1 EDIT: 10/31/2008 3: 38 PM BY MICHAELY 1 PLOT: 11/3/2008 8: 59 AM BY MARK OLEARY -FT 1 SECOND FLOOR PLAN - LIGHTING ZONES SCALE: 1/4"=1'- 0" F- . GENERAL NOTES A. REFER TO ARCHITECTURAL DRAWINGS FOR LUMINAIRE QUANTITIES, LAYOUT AND SPECIFICATION. E DE. COMP N 01 14 2000 08- W(8 Contact Mark O'Leary Project 2008 -0497 INTERFACE —pip— ENGINEERING 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382 2266 FAX 503.382.2262 THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWLA, WASHINGTON SECOND FLOOR PLAN — LIGHTING ZONES Job No: 0826 File Name: Date: 10/31/08 Rev: RECEIVED Nov 06 200€ PERMIT CENTEF Sheet No: E2.12 'LCP1' 2P1 -42. 2P1- 14,18. +90" +46" 2P1- 10,12. 7 2P1 -7,9. /1\ 7:#12 9: #10 1 �- L 14.`' +46_ PANEL '2J1' ry EL '2J2' 10 N PANEL '2P1' PANEL '2M1' PANEL '2K1` PANEL '2K2' 2M1— 34. i LIGHTS 0 FAN TO LIGHTS LIMIT SWITCH L TO LIGHTS J 1 l -101 1c.6b TO FAN TO FAN J +46" 2" (..G:lI E: 7;1111111�G. �prlip► � r.��:���€ 12€ dgi" L 12. 2 +79" 2J1 -30. EL r 2J1 1..16d aW / ..�... �46 all —3 +10" 7 1 23,11 X40. ( +10" \I) EL i'. f 2P1 -4 72 / (F f l €E f 1 / REFER TO KITCHEN EQUIPMENT SCHEDULE FOR ROUTING OF CIRCUIT. 1"C. TO CEILING SPACE 6. I 1l 5 #10 ...:. ...; \ 1:t::::\'\\i'l\-\'''''''i.::,\7\.',...,,,,, j: .,,, / \.v \. i / s '\ S r r • I. STUB —UP CONDUIT AT DESK FOR MUSIC SIGNAL. SEE SHEET E3.02 1 //),11''. \ \ :t // // i ,// / f /r�/ \ \\ r/( 1 "C MOUNT IN DESK / \.\ ` \ Q�( \ ` \ \--\ 6 \ \\ N. \.... ...., ... Y -.-- 1 Jr E °_ r.. 1 '' €1 fF F it f FILE: 0497E3.O1.DWG — E3.01 1 EDIT: 11/21/2008 10 :17 AM BY ANNAS 1 PLOT: 12/23/2008 3:23 PM BY QUINLAN BELOG 1 FIRST FLOO 2 SCALE: 1/4"=1'-0" R PLAN — POWER & SIGNAL 76) SHEET KEYNOTES 0 PROVIDE CONNECTION TO SOLENOID VALVE. COORDINATE WITH DIVISION 15. O PROVIDE CONNECTION TO SIGNAGE. LOCATION PER ARCHITECTURAL DRAWINGS. VERIFY ELECTRICAL REQUIREMENTS WITH SIGNAGE SHOP DRAWINGS PRIOR TO ROUGH —IN. L1 PROVIDE LOW — VOLTAGE CONNECTION TO BUZZER. LOCATE PER OSF PROJECT MANAGER DIRECTION PRIOR TO ROUGH —IN. T : IEWED FOR CODE COMPLIANCE N PA 70 ° NEC . DEC 3 0 2008 City Of Tukwila ELOB(M l 8 DEC 2 6 2008 PERMIT CENTER Contact Mark O'Leary Project 2008 -0497 INTERFACE E N G I N E E R I N G 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 arc i i c tu re 2525 Ede';t �:3tfrE�;3ir;ta t. Portland, OR 97214 503.225.'361/phone 503 229.3 15 fax t£<"ca,Ilp.r.or 1 THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON FIRST FLOOR PLAN POWER 6 SIGNAL Job No: 0826 File Name: Date: 12/17/08 Rev: A CITY REVIEW COMMENTS Sheet No: E3.01 t inc. FROM MUSIC CABINET TO CEILING SPACE FOR MUSIC SIGNAL. 190a 1 ' CRY ( -IR AG I c :..91 HUB 2P1 -45. TELEPHONE TERMINAL BOARD 2P1- 22,24,32. 4+:6�2 4- 0 :..IC E08 • 32= 2 IE 11 11 5 1. tit A Y r O 0'2) N TO COOLER LIGHTS R / +72" 1 24" na AG F 4' t AG RECEPTACLE FOR SINK HAND SENSORS (TYP. OF 8 SINKS) r BL OW E 11 c fib Cc- FILE: 0497E3.02.DWG — E3.02 1 EDIT: 11/21/2008 10:19 AM BY ANNAS 1 PLOT: 12/23/2008 3 :33 PM BY QUINLAN BELOG 11 ............ ......_.._.._......_..._.____-f - 1 SECOND FLOOR PLAN - POWER & SIGNAL 0 2' 4' 8' SCALE: 1/4"=1 '-0" REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC DEC 3 0 2008 Cod Tukwila LOB(4($ CITY DEC 2 6 2008 PERMIT CENTER Contact Mark O'Leary Project 2008 -0497 INTERFACE E N G I N E E R I N G 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 c liter ure LLP 2525 ::f:§ki;. B1 rrw:id0 SL Poaland, OR 97214 503.226,3617 phone 6'03.229.3715 fax THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON SECOND FLOOR PLAN POWER 6 SIGNAL Job No: 0826 File Name: Date: 12/17/08 Rev: CITY REVIEW COMMENTS Sheet No: E3.02 CI ( AC -5 w 31. 83 \.. .' \. `.. N // MAU -1 FILE: 0497E3.03.DWG — E3.03 1 EDIT: 11/21/2008 11 :16 AM BY ANNAS 1 PLOT: 12/23/2008 3:33 PM BY QUINLAN BELOG 33: AC-1 AC -6 AC -4 33 33. AC -2 [1 [1 [ 1 ROOF PLAN - POWER & SIGNAL 0 2' 4' 8' SCALE: 1/4"=-1'-0" 33. 1) 14 (AC- [1 REVIEWED FOR CODE COMPLIANCE NEPA 70 - NEC DEC 3 0 2008 City Of Tukwila a Y !MIMI' nit ' LLF' 2525 [:.mt E3u ¢isk.% 31 Partha d, OR . 97214 5033.22` 3617 phone 50:3.229. :W 15 fax -.soasllp.uorn THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON £LOB-m 18 ROOF PLAN CITY TU Y ALA DEC 2 6 2008 PERMIT CENTER Contact Mark O'Leary Project 2008 -0497 INTERFACE i� ENGINEERING 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 POWER 6 SIGNAL MEM Job No: 0826 File Name: Date: 12/17/08 Rev: CITY REVIEW COMMENTS Sheet No: E3.03 AVAILABLE FAULT AT COMM. MTR. CENTER: 35,606A AVAILABLE FAULT AT TRANSFORMER: 39,700A LINE TYPE LEGEND NEW EXISTING TO REMAIN EXISTING TO BE REMOVED PROVIDE FEED- THROUGH LUG PROVIDE FEED - THROUGH LUG 'LCP1' -4, 2004 �- PANEL '2K1' PANEL `2K2' SHEET KEYNOTES EXISTING MC FEEDER ROUTED TO ABOVE CEILING IN TENAN SPACE. VERIFY LOCATION IN FIELD. PROVIDE DIMMING CONTROL PANEL. REFER TO SHEET E2.11 AND E2.12 FOR CONTROL ZONES. EACH ZONE IS CIRCUITED TO A RELAY BRANCH. EACH MODULE CONTAINS 4 RELAY BRANCHES. EACH MODULE IS POWERED BY ONE 20A CIRCU T FROM PANEL '2P1'. SET SCENES FOR HOUSEKEEPING, LUNCH, DINNER AND OFF HOURS. VERIFY TIME SETTINGS WITH OSF PROJECT MANAGER. PROVIDE WITH INTEGRAL TIMECLOCK AND SWITCH CONTROL IN SECOND FLOOR OFFICE (SEE SHEET E2.02). COPPER FEEDER SCHEDULE 3 #2 CU THWN -2, 1 #8 CU GND., IN 1 -1/4" C. 2004 ) 4 #3/0 CU THWN -2, 1 #6 CU GND., IN 2" C. ELEVATOR 15 -20HP 100AS 100A DUAL ELEMENT FUSES, BUSSMANN POWER MODULE SWITCH PANEL '2J1' 2004 (TYPICAL OF 4) NEUT. BUS (E) COMMERCIAL METER CENTER FULL LENGTH GROUND BUS 1 ONE -LINE DIAGRAM NO SCALE FILE: 0497E5.01.DWG - E5.01 I EDIT: 12/23/2008 11:45 AM BY MARKO I PLOT: 12/23/2008 3 :33 PM BY QUINLAN BELOG Panel '2M1' 120/208V, 3 Ph., 4 W. Flush Mounted, 200A Bus with Main Lug Only / Available Foul ighting & Ap Iiance Branch Panelboard . 9763A RMS 08 -497 OSF TUKWILA Ckt. .o Description / . . 'o• Load 4,608 ill- M C.B. .. - 60/3 Note Ph. A Note C.B. ; -. a 20/1 Load v. - Description / o •ti.n SPARE Ckt. •. 2 1 AC -2 3 - -_ 4,608 M ° K B 2 20/1 -- -- 863 SPARE 4 5 - -- 4,608 M - K C 4 20/1 2 - ICE MAKER / BIN 1 ,608 SPARE 6 7 AC -3 4,608 M 60/3 ! A 6 7 ,, • i , - - 9 - -- 4,608 M - r B 8 10 - 900 M - -- 10 11 - -_ 4,608 M - r G 10 - 900 M - -- 12 1<3 AC -4 3,264 M 45/3 r A 12 15/3 552 M GEF -2 14 15 - -- 3,264 3,264 M M - - I C 14 - - 552 552 M M - -- - -- 16 18 17 - -- 19 AC -5 4,608 M 70/3 1 A - -- 15/3 552 M GEF -3 - 20 21 - -- 4,608 M - 18 B ---- - 552 M - -- 22 23 - -- 4,608 M - 20 0 88 - FREEZER EVAPORATOR COIL - 552 M - -- 24 25 AC -6 1,728 M 25/3 22 A - -- 15/1 528 M EF -1 26 27 - -- 1 ,728 M - 1 9 90 - CONDENSING UNIT - FREEZER 15/1 696 M EF -2 28 29 --- 1,728 M - / 0 - -° 15/1 696 M EF -3 30 • •- - •w - : ` -i 28 A - -- 15/1 50 M EF -4, 5, 6 32 33 R- ROOF 720 R 20/1 30 B 91 - REFRIGERATED SALAD PREP TBL 20/1 60 G SOLENOID VALVE 34 35 SPACE 600 K 20/1 32 0 93 - BREAD WARMER WELL 20/1 360 M WH -1,2 / CP -1,2 36 37 SPACE 720 R 116a,b,c,d - PRINTERS 34 A 94 - OVERHEAD FOOD WARMER 20/1 120 G SPARE 38 39 SPACE 360 R 20/1 36 B -- 20/1 K - SPARE 40 41 SPACE 700 L 20/1 38 0 25 - AIR CURTAIN 20/1 M 20/1 SPARE 42 Total Total Total Connected Load: Ph. A 22,118 VA 184 Amps Panel Connected Load: 66.3KVA 184.1Amps Connected Load: Ph. B 22,296VA 186 Amps Sub -Fed Connected Load: 0.OKVA 0.0 Amps Connected Load: Ph. C 21,876 VA 182 Amps Total Demand Loam 69.7 KVA 193.7 Amin Accessories:Provide Fully Rated Breakers Load Load Description Connected Subfed Total Demand Demand Type Loads Loads (S) Loads Factor Load 0 General (Non - Continuous) 0.06 0.00 0.06 100% 0.06 (KVA Typical) L Lighting 0.00 0.00 0.00 125% 0.00 R Receptacles - to 10 KVA 1.44 0.00 1.44 100% 1.44 over 10 KVA 0.00 0.00 50% 0.00 K Kitchen 0.00 0.00 0.00 100% 0.00 H Heating 0.00 0.00 0.00 100% 0.00 M Motors 50.97 0.00 50.97 100% 50.97 LM Largest Motor 13.82 0.00 13.82 125% 17.28 WH Water Heater 0.00 0.00 0.00 125% 0.00 C Continuous General Load 0.00 0.00 0.00 125% 0.00 Totak 69.75 KVA Panel '211' 120/208V, 3 Ph., 4 W. Flush Mounted, ighting & App once Branch Panelboard 200A Bus with Main Lug Only / Available Faul • 9763A RMS 08 =497 OSF TUKWILA Ckt. No Description / Location Load (VA)IType C.B. A /Pole Note Ph. Note C.B. A /Pole Load (VA)IType Description / Location Ckt. No 1 1 - ICE MAKER / BIN 863 K 20/2 A 30/3 2,100 K 48 - 12 GAL. KETTLE ON STAND 2 3 -- -- 863 K - ® B - 2,100 K - -- 4 5 2 - ICE MAKER / BIN 1 ,608 K 20/3 ® C ® - 2,100 K - -° 6 7 - -- 1,608 K - A _ 15/1 240 K * ** SPACE FOR SHUNT TRIP * ** 49 - FLOOR KETTLE 8 10 9 - -- 1,608 K - B 11 8 - DISH MACHINE 2,364 K 45/3 10 C 128 - FREEZER - U/C DESSERT 600 K 15/1 * ** SPACE FOR SHUNT TRIP * ** 12 13 - -- 2,364 K - 12 A 81, 82 - WALK -IN COOLER LTG, COIL 20/1 1,000 L 50, 73, 1102 - HOOD LIGHTING 14 15 - -- 2,364 K - 14 B 83 - CONDENSING UNIT - COOLER 30/3 2,100 K 61 - 12 GAL. KETTLE ON STAND 16 17 29 - FOOD CUTTER 1,920 K 25/1 16 C - -- - 2,100 K - -- 18 13 42 - HOLDING CABINET 2,300 K 25/1 18 A ---- - 2,100 K - -- 20 21 44a - MICROWAVE 1,600 K 20/2 20 B 88 - FREEZER EVAPORATOR COIL 915 M 15/2 * ** SPACE FOR SHUNT TRIP * ** 22 23 - -- 1,600 K - 22 C - -- 35/3 3,333 K 68 - FUTURE EQUIPMENT 24 25 44b - MICROWAVE 1,600 K 20/2 24 A 90 - CONDENSING UNIT - FREEZER - 3,333 K - -- 26 27 - -- 1,600 K - 26 B - -° - 3,333 K - -- 28 29 45 - CONVECTION OVEN W/ WORKTOP 528 K 15/1 28 C - -- 900 M - * ** SPACE FOR SHUNT TRIP * ** 30 31 * ** SPACE FOR SHUNT TRIP * ** 1,740 K - -- 30 A 91 - REFRIGERATED SALAD PREP TBL 20/1 600 K 70 - FUTURE EQUIPMENT 32 33 46 - BRAISING PAN 600 K 20/1 32 B 93 - BREAD WARMER WELL 2,040 K 25/1 * ** SPACE FOR SHUNT TRIP * ** 34 35 * ** SPACE FOR SHUNT TRIP * ** 720 R 116a,b,c,d - PRINTERS 34 C 94 - OVERHEAD FOOD WARMER 20/1 120 G 79, 80 - FIRE SUPPRESSION SYSTEM 36 37 SPARE 360 R 20/1 36 A -- 20/1 K - SPARE 38 39 SPARE 700 L 20/1 38 8 25 - AIR CURTAIN 20/1 M 20/1 SPARE 40 41 SPARE 800 L 20/1 40 C 87 - WALK -IN FREEZER 20/1 L 20/1 SPARE 42 Tota Tota Total Connected Load: Ph. A 17,868 VA 149 Amps Panel Connected Load: 49.9KVA 138.7 Amps Connected Load: Ph. B 16,408 VA 137 Amps Sub -Fed Connected Load: 47.6KVA 132.3 Amps Connected Load: Ph. C 15,673VA 131AmPs Total Demand Load 71.3KVA 198.0 MPG Accessories: Provide Feed -Thru Lugs Load Load Description Connected Subfed Total Demand Demand Type Loads Loads (S) Loads Factor Load G General (Non - Continuous) 0.12 0.00 0.12 100% 0.12(KVA Typical) L Lighting 1.00 1.92 2.92 125% 3.65 R Receptacles - to 10 KVA 0.00 1.80 1.80 100% 1.80 over 10 KVA 0.00 0.00 50% 0.00 K Kitchen 48.83 30.31 79.14 65% 51.44 H Heating 0.00 3.00 3.00 100% 3.00 M Motors 0.00 7.91 7.91 100% 7.91 LM Largest Motor 0.00 2.70 2.70 125% 3.38 WH Water Heater 0.00 0.00 0.00 125% 0.00 C Continuous General Load 0.00 0.00 0.00 125% 0.00 Totak 71.30 KVA n Panel '212' 120/208V, 3 Ph., 4 W. Flush Mounted Lighting & Ap • lance Branch Panelboard 200A Bus with Main Lug Only / Available Foul . 9763A RMS 08 -497 OSF TUKWILA Ckt. No. Description / Location Load (VA)IType C.B. A /Pole Note Ph. Note C.B. A /Pole Load (VA)IType Description / Location Ckt. No. 1 71- CONVECTION OVEN 888 K 15/1 A 25/2 2,160 K 95 - SANDWICH GRILL 2 3 * ** SPACE FOR SHUNT TRIP * ** 6,624 M ° ® B - 2,160 K - -- 4 5 72 - STEAMER 3,000 K 35/3 ® C ® 20/1 1,020 M 96 - PLATE FREEZER 6 7 __- 3,000 K - A _ 20/2 1,600 K 97 - MICROWAVE OVEN 8 9 - -- 3,000 K - B - 1,600 K - -- 10 11 128 - FREEZER - U/C DESSERT 600 K 15/1 C 20/1 1 ,080 M 98 - REFRIGERATED SANDWICH TBL 12 13 81, 82 - WALK -IN COOLER LTG, COIL 718 L 20/1 1 A _ 20/1 1,000 H EDH -1 14 15 83 - CONDENSING UNIT - COOLER 792 M 20/3 1 B _ 20/1 1,000 H - -- 16 17 - -- 792 M - K C 20/1 1,000 H - -- 18 19 ---- 792 M - M A 20/3 1,236 K 100 - HOT WELL 20 21 88 - FREEZER EVAPORATOR COIL 915 M 15/2 M B - 1,236 K - -- 22 23 - -- 915 M - 198, 199 - BEER COOLER, EVAPOR. C M - 1,236 K - -- 24 25 90 - CONDENSING UNIT - FREEZER 900 M 15/3 1 A M M 20/3 1,740 K 101 - HOT WELL 26 27 - -° 900 M - 1 B 900 - 1,740 K - -- 28 29 - -- 900 M - 1 C 1,440 - 1,740 K - -- 30 31 91 - REFRIGERATED SALAD PREP TBL 1,200 M 20/1 1 A 1,320 360 20/1 1,080 R 114a,b,c,d,e,f - POS SYSTEM & PRINTERS32 32 33 93 - BREAD WARMER WELL 2,040 K 25/1 1 B A 20/1 720 R 116a,b,c,d - PRINTERS 34 35 94 - OVERHEAD FOOD WARMER 666 K 15/2 1 C B 20/1 360 R SPARE 36 37 -- 666 K - 1 A C 20/1 700 L SPARE 38 39 25 - AIR CURTAIN 408 M 20/1 1 8 20/1 800 L SPARE 40 41 87 - WALK -IN FREEZER 1,200 L 20/1 1 C 20/1 250 C SPARE 42 Total Tota Total Connected Load: Ph. A 16,980 VA 142 Amps Panel Connected Load: 47.6KVA 132.3 Amps Connected Load: Ph. B 16,511VA 138 Amps Sub -Fed Connected Load: 0.0KVA O.OAmps Connected Load: Ph. C 14,149VA 1 18Amps Total Demand Load Refer to Section 1 Panel '2P1' 120/208V, 3 Ph., 4 W. Flush Mounted, ighting & Ap,‘Iiance Branch Panelboard 200A Bus with Main Lug Only / Available Foul '7.3A RM 08 -497 OSF TUKWILA Ckt. o Description / • 0 o e Load a- C.B. ; .. - Note Ph. Note C.B. A /Pole Load (VA)IType Description / Location Ckt. No. 1 AC -1 6,624 M 90/3 A 20/1 720 R R- VESTIBULE HOSTESS 2 3 __° 6,624 M ° ® B 20/1 720 R R- VEST., BAR SEATING /TV, S. SEATING 4 5 °°- 6,624 M - ® C ® 20/1 720 R R- S. SEATING, N. SEATING 6 7 0 ,Doh • .ii ' - • A _ 20/1 900 R R- KITCHEN CONV. 8 9 WINDOW SIGNAGE 900 R 20/1 B 20/1 540 R R- KITCHEN , ADDITIONAL SEATING 10 11 WINDOW SIGNAGE 900 R 20/1 C 20/1 720 R R- ADNL SEAT., BAR SEAT., CORRIDOR 12 13 SIGNAGE 1200 L 20/1 1 A _ 20/1 390 R R- KITCHEN CONV., BUZZER 14 15 SIGNAGE 1,200 L 20/1 1 B _ 20/1 540 R R- KITCHEN CONV. 16 17 STAIRS, 2ND FL CORRIDOR 770 L 20/1 K C 20/1 1 ,400 R R- 2ND FL RR, MECH., EMPLOYEE TBL 18 19 2ND FL BACK ROOMS 1,364 L 20/1 M A 20/1 940 R R- 2ND FL CONV, RR, STRG. 20 21 1ST FL KITCHEN NORTH 1,302 L 20/1 M B 20/1 360 R R- 2ND FL COMP. ROOM 22 23 1ST FL KITCHEN SOUTH 912 L 20/1 198, 199 - BEER COOLER, EVAPOR. 0 M 20/1 360 R R- 2ND FL COMP. ROOM 24 25 ENTRY, ZONE: 13,14 1,722 L 20/1 1 A M M 20/1 420 R R- ELEVATOR PIT 26 27 BAR, ZONE: 4,5,6,7,8 1,778 L 20/1 1 B 900 20/1 62 L L- ELEVATOR MACHINE ROOM 28 29 BANQUET, ZONE: 9,10,12 1,570 L 20/1 1 C 1,440 20/1 360 R R- TELEVISIONS, BAR 30 31 BANQUET, RR, ZONE: 11,25,29,31 1,691 L 20/1 1 A 1,320 360 20/1 720 R R- 2ND FL COMP. ROOM, CONV. 32 33 2ND FL DINING, ZONE: 22,26,27,28 819 L 20/1 1 B A 20/1 360 R R- MUSIC SYSTEM 34 35 WEST DINING, ZONE: 1,2021,30 1,748 L 20/1 1 C B 20/1 360 R R- TELEPHONE TERMINAL BOARD 36 37 MAIN STAIR, DINING, ZONE: 17,19,23,24 1,449 L 20/1 1 A C 20/1 700 L EXIT SIGNS 38 39 1ST FL N, MAIN DINING, ZN: 2,3,16,18 1,238 L 20/1 1 B 20/1 800 L L- EXTERIOR EGRESS 40 41 1ST FL S DINING, ZN: 15 1,290 L 20/1 1 C 20/1 250 C CONTACTOR, DIMMING CONTROL 42 43 L- KABOOSE 300 L 20/1 A 20/1 SPARE 44 ;e.-• -• ; -A B 20/1 SPARE 48 47 MAU -1 1,056 M 15/3 C 20/1 SPARE 48 49 - -- 1,056 M - A 20/1 SPARE 50 51 - -_ 1,056 M - B 20/1 SPARE 52 ota Total Total onnec e• _oa•: - ,;' • rA . Amps Panel Connected Load: 58.8KVA 163.3 Amps Connected Load: Ph. B 18,659 VA 155 Amps Sub -Fed Connected Load: O.OKVA 0.0 Amps Connected Load: Ph. C 19,040 VA 159Amps Total Demand Load 67.5KVA 187.5 Amin Notes: 1.PROVIDE HANDLE -TIE FOR MULTI -WIRE BRANCH CIRCUIT. Load Load Description Connected Subfed Type Loads Loads (S) G General (Non - Continuous) 0.00 0.00 L Lighting 21.92 0.00 R Receptacles - to 10 KVA 13.59 0.00 over 10 KVA 0.00 K Kitchen 0.00 0.00 H Heating 0.00 0.00 M Motors 3.17 0.00 LM Largest Motor 19.87 0.00 WH Water Heater 0.00 0.00 C Continuous General Load 0.25 0.00 Total Demand Demand Loads Factor Load 0.00 100% 0.00 (KVA Typical) 21.92 125% 27.39 10.00 100% 10.00 3.59 50% 1.80 0.00 100% 0.00 0.00 100% 0.00 3.17 100% 3.17 19.87 125% 24.84 0.00 125% 0.00 0.25 125% 0.31 Totak 67.51 KVA Panel '2J1' 120/208V, 3 Ph,, 4 W. Flush Mounted, ' ghting & Ap lance Branch Panelboard 200.0 Bus with Main Lug Only /Available Fault, 9763A RMS 08 -497 OSF TUKWILA Ckt, No. Description / Location Load (VA)�Type C.B. A /Pole Note Ph, Note C.B. A /Pole Load (VA)�Type Description / ocation Ckt. No. 1 99a - HEATED WORK CABINET 1,354 K 20/3 A 20/1 1,020 M 125 - FREEZER 2 3 - -- 1,354 K - ® B 20/1 1,320 M 129a - FREEZER - ICE CREAM 4 5 - -- 1 ,354 K - ® C ® 20/1 1,320 M 129b - FREEZER - ICE CREAM 6 7 99b - HEATED WORK CABINET 1,354 K 20/3 A _ 20/1 1,320 M 131 - FREEZER - ICE CREAM 8 9 _ -- 1,354 K - B 15/2 624 K 134a, b - SOUP WELL 10 II - -- 1,354 K - C - 624 K - -- 12 13 SPARE 180 20/1 A _ 20/1 360 R 137, 138 - TEA BREWER, MILK DISP. 14 15 17 SPARE SPARE 1,800 . 20/1 20/1 B 0 _ 20/1 30/2 540 1,800 R K 139a, b, 140 DISPENSERS 4 - COFFEE BREWER - -- 118 106a, b - PASTA COOKER 480 K 15/1 A - 1,800 K -°- 20 21 108 - WORK TOP FREEZER 816 M 15/1 B _ 30/2 1 ,800 K 142b - COFFEE BREWER 22 23 109 - REACH -IN REFRIGERATOR 660 M 15/1 C - 1,800 K - -- 24 25 SPARE 25 198, 199 - BEER COOLER, EVAPOR. 20/1 M A 20/1 864 M 145 - COOLER -RED WINE 26 27 29 SPARE 117a - OVERHEAD FOODWARMER _• 3,150 K 20/1 M M B 20/1 864 M 146 °COOLER WHITE WINE 28 35/2 0 _ 20/1 900 M 149 - BACK BAR COOLER 30 A 20/1 SPARE 33 35 204 - BOOSTER HEATER SPARE 1,440 ®163a 20/1 20/1 33 117b - OVERHEAD FOODWARMER - -- • 3,150 K ® - e■ C • 20/1 1,320 360 - R GLASSOBRUSHS 35 R -BAR CONV. RECEPTACLE 36 37 SPARE 20/1 38 A _ 20/1 720 R R - BAR CONY. RECEPTACLE 38 39 SPARE 20/1 B _ 20/1 360 R ' - CONV. RECEPTACLE 40 41 SPARE _. SPARE 20/1 Total Total Total C 20/1 SPARE 42 Tota Tota Tota Connected Load: Ph, A Connected Load: Ph. B Connected Load: Ph. C 13,862VA 13,502VA 16,472VA 116Amps 113AmPs 137Amps Panel Sub -Fed Connected Connected Total Load: 43.8KVA 121,8Amps Load: 36.4KVA lO1.2Amps Demand Load 70.1KVA 194.7 Accessories: Provide Feed -Thru Lugs Load Load Description Type 0 General (Non - Continuous) L Lighting R Receptacles - to 10 KVA over 10 KVA K Kitchen H Heating M Motors LM Largest Motor WH Water Heater C Continuous General Load Connected Subfed Total Demand Demand Loads Loads (S) Loads Factor Load 0.00 0.00 0.00 100% 0.00(KVA Typical) 0.00 0.00 0.00 125% 0.00 2.34 0.54 2.88 100% 2.88 0.00 0.00 50% 0.00 32.41 11.97 44.38 65% 28.85 0.00 0.00 0.00 100% 0.00 9.08 2.55 11.63 100% 11.63 0.00 21.38 21.38 125% 26.73 0.00 0.00 0.00 125% 0.00 0.00 0.00 0.00 125% 0.00 Totak 70.09 KVA arc nierture LLF' 2525 t a$3t. B irn;;&kle t. Purtia }d OR 137214 503.22'6.3617 phono 03 22s .3715 fax i.c�1�;J.GO €9S VIEWED FOR C i)DE COMPLIANCE N }A')A70 -NEC DEC 3 0 2000 THE OLD SPAGHETTI aoBIM18 FACTORY Panel '2�2' 120/208V, 3 Ph., 4 W. Flush Mounted, ighting & Appl'•nce Branch Panelboard 200.0 Bus with Main Lug Only /Available Fault 9763A RMS 08 °497 OSF TUKWILA Ckt. No. Description / Location Load (VA)IType C,B. A /Pale Note Ph. Note C.B. A /Pole Load (VA)IType Description / Location Ckt. No. 1 SPARE 20/1 A 100/3 7,128 M ELEVATOR 2 3 166 - GLASS FROSTER 696 M 15/1 ® B - 7,128 M - -- 4 5 168 - OASIS MACHINE 750 K 20/1 C ® - 7,128 M - -- 6 7 179 - OVERHEAD FOODWARMER 500 K 15/1 A _ 20/1 _-SPARE 8 9 180 - HOT WELL 996 K 15/1 B 20/1 SPARE 10 11 184, 188 - LEMONADE, SODA DISP. 360 R 20/1 C 20/1 _-SPARE • 12 V 180 20/1 20/1 SPARE 14 15 187 - COF EE BREWER 1,800 K 30/2 B • SPARE 17 - -- 1,800 K - 0 20/1 SPARE 18 1D 19Oa - REMOTE 1,440 20/1 • SPARE 21 23 190b - REMOTE CARBONATORS SPARE _. ® 20/1 20/1 ®e� C 1 20/1 SPARE SPARE 24 25 198, 199 - BEER COOLER, EVAPOR. 416 M 15/1 A 20/1 _-SPARE 26 27 29 200 - BEER COOLER CONDENSER - -- 718 718 M M 20/2 ° B C _ 20/1 20/1 SPARE SPARE 31 203 - GLYCOL SYSTEM 1,800 K 20/1 A 20/1 SPARE 33 35 204 - BOOSTER HEATER SPARE 1,440 K 20/1 20/1 B C _ _ 20/1 20/1 _-SPARE _-SPARE 34 36 37 SPARE • • SPARE 38 39 SPARE • 20/ 1 • SPARE 41 SPARE _. 20/1 C _ 20/1 _ SPARE Total Total Total Connected Load: Ph. A 11,464 VA 96 Amps Panel Connected Load: 36.4KVA 1O1.2AmPs Connected Load: Ph. B 14,218VA 118AmPs Sub -Fed Connected Load: 0.OKVA 0.0 Amps Connected Load: Ph. C 10,756VA 90 Amps Total Demand Load Refer to Section 1 PANEL SCHEDULE 2M1 2P1 2K1 2J1 2K2 2J2 SOUTHCENTER SQUARE TUKWILA, WASHINGTON ONE LINE DIAGRAM, PANEL SCHEDULES ELECTRICAL Job No: 0826 Ci1Y IV LA File Name: DEC 2 6 10118 PERMIT CENTER Contact Mark O'Leary Project 2008 -0497 T INTERFACE ENGINEERING 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 Date: 12/17/08 Rev: CITY REVIEW COMMENTS Sheet No: E5.01 A TO MOTOR ELEVATOR CAR ELEVATOR MACHINE ROOM TYP. ELEVATOR LOBBY ELEVATOR CONTROLLER/ DRIVE TO FIRE ALARM SYSTEM 16 TYP ELEVATOR LOBBY ELEVATION NEUTRAL PHASE HOOD FIRE SUPPRESSION 2P1 -26. NOTES THIS DETAIL O MOUNT WEATHERPROOF TOGGLE SWITCH FOR PIT LIGHT CIRCUIT BY TOP OF PIT LADDER. NG 0 PROVIDE SURFACE MOUNTED FLUORESCENT STRIPLIGHT. FOUR FOOT COLD ROLLED STEEL CHANNEL. WHITE FINISH, WIREGUARD. LAMPS GUARDED WITH CLEAR PLASTIC SLEEVES. TWO 32 WATT T8 LAMPS. LITHONIA C SERIES, METALUX, DAYBRITE, HUBBELL, LIGHTOLIER OR APPROVED. TYPICAL OF TWO. MOUNT ONE LUMINARIE ON THE FRONT ELEVATOR WALL, THE SECOND ON THE REAR ELEVATOR PIT WALL. AVOID LOCATING FIXTURES DIRE TLY BEHIND BEAMS OR STRUCTURE THAT WOULD BLOCK LIGHTING. Q NOT USED. MOUNT 135' FIXED TEMPERATURE HEAT DETECTOR TO WITH 24 INCHES OF EACH SPRINKLER HEAD IN ELEVATOR MACHINE R OM AND HOISTWAY. �5 MOUNT SMOKE DETECTOR IN ELEVATOR LOBBY ON CEILING 10 WITHIN 21 FEET OF ELEVATOR DOOR. ELEVATOR FEEDER FROM POWER DISTRIBUTION PANEL CONTROL WIRING FUSIBLE SHUNT TRIP POWER MODULE TO FIRE ALARM SYSTEM BATTERY _ ELEVATOR LOWERING CONTROLLER/ DEVICE = DRIVE CONTROL SIGNAL FROM AUTOMATIC TRANSFER SWI -CH WIRING SCHEMATIC HYDRAULIC TYPE ELEVATOR DETAIL ADDRESSABLE FIRE ALARM SYSTEM POWER PACK OVERRIDE (OFF) SWITCH LOCATED IN SAME SPACE AS LUMINARIES PROVIDE ONLY IF INDICATED ON PLANS LOW VOLTAGE CABLE FOR MANUFACTURER REQUIREMENTS Q TO NEXT REMOT1 SENSOR IF REQ IRED 24VDC REMOTE SENSOR 2 OCCUPANCY SENSOR CONTROL DIAGRAM ISYSTEM NO SCALE HOOD CONTROLLER 71 N0/ 1 ION COMMON OFF I I I TO HOOD LIGHTS TERMINAL - BLOCK TO OTHER HOOD EXHAUST FANS SHUNT TRIP BREAKERS OR CONTACTORS FOR LOADS UNDER CLASS I HOOD. TO OTHER ? MAKE -UP AIR UNITS GAS SOLENOID VALVE(S) INCOMING FEEDER / \ INCOMING FEEDER TO MOTOR TO OTHER SHUNT -TRIP BREAKERS OR CONTACTORS SEQUENCE OF OPERATION 1. WHEN HOOD EXHAUST FAN(S) ARE STARTED THEN START MAKE AIR UNITS) 2. WHEN HOOD EXHAUST FAN(S) ARE STOPPED THEN STOP MAKE -UP AIR UNIT(S) 3. WHEN HOOD FIRE SUPPRESSION SYSTEM IS ACTIVATED THEN SHUT OFF MAKE UP AIR UNIT AND, TURN OFF EQUIPMENT UNDER CLASS I HOOD, CLOSE GAS SOLENOID VALVES AND SEND ALARM SIGNAL TO FIRE ALARM SYSTEM. 3 HOOD CONTROL AND FIRE SUPPRESSION WIRING DIAGRAM NO SCALE FILE: 0497E6.01.DWG - E6.01 1 EDIT: 12/23/2008 11:44 AM BY MARKO 1 PLOT: 12/23/2008 3:39 PM BY QUINLAN BELOG MOUNT SHUNT POWER MODULE TO WITHIN 24 INCHES OF STRIKE SIDE OF DOOR TO ELEVATOR MACHINE ROOM. 7® PROVIDE DEDICATED CIRCUIT. ROUTE INCOMING CIRCUIT TO LUMINARIES UPSTREAM OF GFCI RECEPTACLE IN BOTH MACHINE ROOM AND ELEVATOR PIT, PER N.E.C. ARTICLES 620.23 AND 620.24. PROVIDE FUSIBLE SHUNT TRIP POWER MODULE WITH CONTROL TRANSFORMER, TEST SWITCH, PILOT LIGHT, AUXILIARY CONTACTS AND ALARM CONTACTS. PROVIDE 200 AMP, 3 POLE SWITCH. BUSSMAN, FERRAZ - SHAWMUT, LITTLEFUSE OR APPROVED. ® PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER /DRIVE FOR ELEVATOR PRIMARY RECALL, SEE WIRING SCHEMATIC. 10 PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO SHUNT TRIP CONTROL OF ELEVATOR POWER, SEE WIRING SCHEMATIC. 11 ROOM LIGHTING; SEE FLOOR PLAN FOR TYPE, QUANTITY AND CIRCUITING. 12 PROVIDE SEPARATE DEDICATED CIRCUITS AND LOCKABLE CIRCUIT BREAKERS FOR ELEVATOR CAR LIGHTS AND HVAC. LOCATE IN ELEVATOR MACHINE ROOM NEAR ENTRY DOOR. PROVIDE A SIGN TO IDENTIFY THE LOCATION OF THE OVERCURRENT PROTECTIVE DEVICES. INDICATE TYPE OF LOAD NEXT TO EACH CIRCUIT BREAKER. 13 PROVIDE HEAT AND SMOKE DETECTORS AT THE TOP OF EACH ELEVATOR SHAFT, WHEN SPRINKLERED. CONNECT TO F.A. SYSTEM INITIATING DEVICE CIRCUIT. COORDINATE WALL MOUNTING SPACE FOR ELECTRICAL EQUIPMENT WITH ELEVATOR SUPPLIER /INSTALLER PRIOR TO ROUGH -IN. 16 PROVIDE DEDICATED PHONE LINE IN 3/4" C. TO TELEPHONE TERMINAL BOARD. 17 PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER TO ACTIVATE FIREMAN HAT LIGHT IN ELEVATOR CAB UPON INITIATION OF SMOKE DETECTION IN ELEVATOR SHAFT OR MACHINE ROOM. O. CONNECT TO F.A. SYSTEM FOR MONITORING OF CONTROL POWER. 19 PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER FOR ELEVATOR ALTERNATE RECALL. SEE WIRING SCHEMATIC. L E G E N D 1- COPPER GROUND BAR 2- INSULATORS 3- 5/8" LOCKWASHERS 4- WALL MOUNTING BRACKET 5- 5/8 -11 X 1" H.H.C.S.BOLTS 6- BARE COPPER GROUND CONDUCTOR TO MAIN SERVICE EQUIPMENT GROUND. REFER TO SPECIFICATIONS FOR CONDUCTOR SIZE. TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB) DETAIL NO SCALE Kitchen Connection Schedule Item Description Volta / Phase Load Wlre / Conduit Circuit Notes 1 ICE MAKER /BIN 208/1 8.3 A 202 2K1 -1,3. v ,�,-,er- 2 ICE MAKER /BIN 208/3 13.4 A 203 2K1- 5.7,9. 90 8 DISH MACHINE 208/3 19.7 FLA 303 2K1- 11,13,15. 48.0 MCA 25 AIR CURTAIN 120/1 3.4 A 202 2K2 -39. 208/3 29 FOOD CUTTER 120/1 1.0 HP 202 2K1 -17. Air Conditioning Unit 42 HOLDING CABINET 120/1 2.3 KW 302 2K1 -19. AC -5 44a MICROWAVE OVEN 208/1 3.2 KW 202 2K1- 21,23. 44b MICROWAVE OVEN 208/1 3.2 KW 202 2K1 -25,27. 2M1- 25,27,29. . _, • :- ... - 120/1 ., 2K1 -29. 1 2M1 -36. 46 BRAISING PAN (EXISTING) Circulation Pump 120/1 202 2K1 -33. 1,2 4; 1 G' ' L 0' A D • • +.3 K" 0 2K1- 2,4,6. 1 49 FLOOR KETTLE 120/1 2.0 A 202 2K1 -10. 1 50 TYPE 1 HOOD 120/1 0.4 KW 202 2K1 -14. LTS 61 12 GAL KETTLE ON STAND 208/3 6.3 KW 303 2K1- 16,18,20. 1 68 SPARE - FUTURE EQUIPMENT 208/3 10.0 KW 403 2K1- 24,26,28. 1 70 SPARE - FUTURE EQUIPMENT 1 20/1 5.0 A 202 2K1 -32. 1 71 CONVECTION OVEN 120/1 7.4 A 202 2K2 -1. 1 72 STEAMER 208/3 9.0 KW 403 2K2 - 5,7,9. 202 73 TYPE 1 HOOD 120/1 0.5 KW 202 2K1 -14. LTS 79 FIRE SUPPRESSION SYSTEM 120/1 60 W 202 2K1 -36. 1.0 HP _ -- 80 FIRE SUPPRESSION SYSTEM 120/1 60 W 202 2K1 -36. 208/3 81 WALK -IN COOLER 120/1 0.5 KW 202 2K2 -13. Vake Ip . 'r nit 82 COOLER EVAPORATOR COIL 120/1 218 W 202 2K2 -13. WH -1 83 CONDENSING UNIT - COOLER 208/3 1.5 HP 203 2K2 - 15,17,19. 87 WALK -IN FREEZER 120/1 1.2 KW 202 2K2 -41. 2M1 -36. 88 FREEZER EVAPORATOR COIL 208/1 8.8 A 202 2K2 - 21,23. 90 CONDENSING UNIT - FREEZER 208/3 2.0 HP 203 2K2 - 25,27,29. B. MOCP = Maximum over current protection 91 REFRIGERATED SALAD PREP TABLE 120/1 10.0 A 202 2K2 -31. 303 3 #10 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 93 BREAD WARMER WELL 120/1 17.0 A 302 2K2 -33. 94 OVERHEAD FOODWARMER 208/1 6.4 A 202 2K2- 35,37. 95 SANDWICH GRILL 208/1 18.0 A 302 2K2 -2,4. 96 PLATE FREEZER 120/1 8.5 A 202 21(2 -6, 97 MICROWAVE OVEN 208/1 3.2 KW 202 2K2 -8,10. 98 REFRIGERATED SANDWICH TABLE 120/1 9.0 A 202 2K2 -12. 99a HEATED WORK CABINET 208/1 2.5 KW 203 2J1- 1,3,5. 3 99b HEATED WORK CABINET 208/1 2.5 KW 203 2J1- 7,9,11. 3 100 HOT WELL 208/3 10.3 A 203 2K2 - 20,22,24. 101 HOT WELL 208/3 14.5 A 203 2K2 - 26,28,30. 102 TYPE 2 VAPOR HOOD 120/1 0.1 KW 202 2K1 -14. LTS 106a PASTA COOKER 120/1 2.0 A 202 2J1 -19. 106b PASTA COOKER 120/1 2.0 A 202 2J1 -19. 108 WORK TOP FREEZER 120/1 6.8 A 202 2J1 -21. 109 REACH -IN REFRIGERATOR 120/1 5.5 A 202 2J1 -23. 114a POS SYSTEM & PRINTERS 120/1 1.5 A 202 2K2 -32. 4 114b POS SYSTEM & PRINTERS 120/1 1.5 A 202 2K2 -32. 4 114c POS SYSTEM & PRINTERS 120/1 1.5 A 202 2K2 -32. 4 114d POS SYSTEM & PRINTERS 120/1 1.5 A 202 2K2 -32. 4 114e POS SYSTEM & PRINTERS 120/1 1.5 A 202 2K2 -32. 4 114f POS SYSTEM & PRINTERS 120/1 1.5 A 202 2K2 -32. 4 116a PRINTERS 120/1 1.5 A 202 2K2 -34. 116b PRINTERS 120/1 1.5 A 202 2K2 -34. 116c PRINTERS 120/1 1.5 A 202 2K2 -34. 116d PRINTERS 120/1 1.5 A 202 2K2 -34. 117a OVERHEAD FOODWARMER 208/1 6.3 KW 402 2J1- 29,31. 117b OVERHEAD FOODWARMER 208/1 6.3 KW 402 2J1- 33,35. 125 FREEZER 120/1 8.5 A 202 2,11-2. 128 FREEZER - UNDERCOUNTER DESSERT 120/1 5.0 A 202 2K2 -11. 1 129a FREEZER - ICE CREAM 120/1 11.0 A 202 2J1 -4. 129b FREEZER - ICE CREAM 120/1 11.0 A 202 2J 1 -6. 131 FREEZER - ICE CREAM 120/1 11.0 A 202 2J 1 -8. 134a SOUP WELL 208/1 3.0 A 202 2J1- 10,12. 134b SOUP WELL 208/1 3.0 A 202 2J1- 10,12. 137 TEA BREWER 120/1 1.5 A 202 2J1 -14. 138 MILK DISPENSER 120/1 1.5 A 202 2J1 -14. 139a SODA DISPENSER 120/1 1.5 A 202 2J1 -16. 139b SODA DISPENSER 120/1 1.5 A 202 2J1 -16. 140 LEMONADE DISPENSER 120/1 1.5 A 202 2J1 -16. 142a COFFEE BREWER 208/1 15.0 A 303 2J1- 18,20. 2,3 142b COFFEE BREWER 208/1 15.0 A 303 2J1- 22,24. 2,3 145 COOLER - RED WINE 120/1 7.2 A 202 2J1 -26. 146 COOLER - WHITE WINE 120/1 7.2 A 202 2J1 -28. 149 BACK BAR COOLER 120/1 7.5 A 202 2J1 -30. 150 CARBONATORS 120/1 12.0 A 202 2J1 -32. 163 GLASS BRUSH 120/1 11.0 A 202 2J1 -34. i 2J2 -3. �, . • . .. 168 OASIS MACHINE (OWNER) 202 2J2 -5. 2 •, - -•g -i ••i.,.1 -, - . .• r,. • 2J2 -7. 180 HOT WELL 120/1 8.3 A 202 2J2 -9. 184 LEMONADE DISPENSER 120/1 1.5 A 202 2J2 -11. 186 TEA BREWER 120/1 1.5 A 202 2J2 -13. 187 COFFEE BREWER 208/1 15.0 A 303 2J2- 15,17. 2,3 188 SODA DISPENSER 120/1 1.5 A 202 2J2 -11. 190a REMOTE CARBONATORS 120/1 12.0 A 202 2J2 -19. 190b REMOTE CARBONATORS 120/1 12.0 A 202 2J2 -21. 198 BEER COOLER 120/1 0.2 KW 202 2J2 -25. . . - c • • . -. • • - 120/1 1.8 A 202 2J2 -25. 200 BEER COOLER CONDENSER (ON ROOF) 208/1 3/4 HP 202 2,12-27,29. 20 L CO * E 120/1 15.0 A 202 2J2 -31. 204 BOOSTER HEATER 120/1 12.0 A 202 2J2 -33. General Kitchen Equipment Connection Schedule Notes A- Refer to kitchen consultant drawings for exact locations and connection types. Coordinate connection with supplied equipment and vendor drawings. Kitchen Equipment Connection Schedule Notes 1 Provide shunt trip breaker. Interlock with fire suppression system. Refer to detail 3 / E6.01. 2 Verify requirements prior to rough -in. 3 Pro-fide wire for 120V connection. 4 Route power via Point of Sale Hub. Maximum of 6 registers. Copper Feeder Schedule 202 2 #12 CU THWN -2, 1 #12 CU GND., IN 3/4" C. 203 3 #12 CU THWN -2, 1 #12 CU GND., IN 3/4" C. 302 2 #10 CU THWN -2, 1 #10 CU CND., IN 3/4" C. 303 3 #10 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 402 2 #8 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 403 3 #8 CU THWN -2, 1 #10 CU GND., IN 3/4" C. Mechanical Equipment Connection Schedule Item Description Volts / Phase Load - MOCP Wire / Condidt Circuit Notes ,�,. se se- sr ,- Y- v ,�,-,er- v Y se" se- Y AC -1 Air Conditioning Unit 208/3 69.0 MCA 90 703 2P1- 1,3,5. AC -2 Air Conditioning Unit 208/3 48.0 MCA 60 553 2M1- 1,3,5. AC -3 Air Conditioning Unit 208/3 48.0 MCA 60 553 2M1-7,9,11. AC -4 Air Conditioning Unit 208/3 34.0 MCA 45 403 2M1- 13,15,17. AC -5 Air Conditioning Unit 208/3 48.0 MCA 70 553 2M1- 19,21,23. AC -6 Air Conditioning Unit 208/3 18.0 MCA 25 303 2M1- 25,27,29. CP -1 Circulation Pump 120/1 1 1 HP 20 202 2M1 -36. CP -2 Circulation Pump 120/1 1/12 HP 20 202 2M1 -36. EDH -1 Electric Duct Heater 208/3 3.0 KW 20 203 2K2 - 14,16,18. EF -1 Exhaust Fan 120/1 1/5 HP 15 202 2M1 -26. EF -2 Exhaust Fan 120/1 1/4 HP 15 202 2M1 -28. EF -3 Exhaust Fan 120/1 1/4 HP 15 202 2M1 -30. EF -4 Exhaust Fan 120/1 50.0 W 15 202 2M1 -32. 2 EF -5 Exhaust Fan 120/1 50.0 W 15 202 2M1 -32. 2 - . - - - - - .. , : . . 120/1 50.0 W 15 202 2M1 -32. GEF -1 Exhaust Fan 208/3 2.0 HP 15 203 2M1- 8,10,12. 1 GEF -2 Exhaust Fan 208/3 1.0 HP 15 203 2M1- 14,16,18. 1 GEF -3 Exhaust Fan 208/3 • • _ i MAU -1 Vake Ip . 'r nit 208/3 - 11.0 MCA 15 .0 - 203 _ _- 2P1 - 37,39,41. ` _1� _ 1 WH -1 Water Heater 120/1 50.0 W 15 202 2M1 -36. WH -2 Water Heater 1 20/1 50.0 W 15 202 2M1 -36. General Mechanical Equipment Connection Schedule Notes A The above information is for a specific manufacturer. Actual manufacturer for the equipment may be different. Coordinate with mechanical equipment submittals for loads and over current protection requirements prior to installation of wiring. B. MOCP = Maximum over current protection MCA = Minimum circuit ampacity Mechanical Equipment Connection Schedule Notes 1 Interlock with hood exhaust and fire suppression system. Refer to detail 3 / E6.01. 2 Interlock with lighting control in room. 202 2 #12 CU THWN -2, 1 #12 CU GND., IN 3/4" C. 203 3 #12 CU THWN -2, 1 #12 CU GND., IN 3/4" C. 303 3 #10 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 403 3 #8 CU THWN -2, 1 #10 CU CND., IN 3/4" C. 553 3 #6 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 703 3 #4 CU THWN -2, 1 #8 CU CND., IN 1" C. - .MEWED FOR CODE COMPLIANCE A70 -NEC DEC 3 0 2008 4/11 D i►rOkMIll1d ELOB IM(8 CITYLA DEC 2 6 2008 PERMIT CENTER Contact Mark O'Leary Project 2008-0497 INTERFACE E N G I N E E R I N G 708 S.W. 3RD AVE., SUITE 400, PORTLAND, OR 97204 PHONE 503.382.2266 FAX 503.382.2262 arc 1111111/11rMas,•_. !lecture L 2525 E;,.wt Btir 3s d& St. Portland, OR 47214 503,226,3617 phon 50122(3.3715 fax THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWILA, WASHINGTON DETAILS, CONNECTION SCHEDULES ELECTRICAL Job No: 0826 File Name: Date: 12/17/08 Rev: CITY REVIEW COMMENTS Sheet No: E6.01 TYPICAL :1 1 E6.01 ; 1 - ........ ...... 17:: . . .. . . ......... .. . : . . ...... .• • ... •• • ... ' ' ; I ! ..... • ..... .... ...... • 11 • C3 2P1 19. - DOWN 1 ... ! 1 .... . L '• F .. .... _ _ 03 C3 • , • ! ! ! 11 „ e ' ! C 3ra C 4 la) F Iv11 ; Fl -.I .... 1- • 1! ; I ! .. . ; . = Fl 2P1-33. ' F1 •-:, ot ' 1 : „ H .' 1 -- -, 3, 4 ! ; ...... .._.... .... ; . ; F1 UII 0 Y. jtjr1:17:1: ...... ::" . . F 1 .. . - ... 1 04 C4 C4 P13 04 P11 P12 E 2 E4 V' 'V , . , , , ErE 3 20' - , ; 1 , . , • 2P1— 35. • C7 C7 07 C7 . : . 2P1-37. C6 1; P2 - P2 C6 C6 ..... .... _ ..... ______ ..... ......: . . - 1.• 3/4.1*c. C6 C6 C6 •-• • ••• •-• • •• -• ........ • • • P2 06 2 ....... ••• .. • • ........ .. .. . . -" 1 ! C 2 A E2 . .... _...... ! .... . .. . ; ! ; i ! I • z C6 OREN TO BELOW P1 N.11:11111111 C6 P2 C6 C6 ; C6 . _ . . ... .... . . . ........... ..... FILE: 0497E2.02,DWG — E2.02 I EDIT: 5/6/2009 10:16 AM BY ANNAS I PLOT: 5/6/2009 2:2E PM BY ANNA SANDYS . ......... ...... ..... .... . . ...... .. •. .... . ...... ....... L. • 1 SECOND FLOOR PLAN - LIGHTING 0 2' 42 a' cierstesamr!." SCALE: 1/4"---1'— 0" ... ... ............... SEPARATE PERMIT REQUIRED FOR: Ei Mechanical 0 Electrical Plumbing EXGas Piping City of Tukwila ........... . . .... ..... ................ .. ... ...... . ... :! REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. , NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ... GENE AL NOTES A. REFER TO ARCHITECTURAL DRAWINGS FOR LUMINAIRE QUANTITIES, LAYOUT AND ADDITIONAL SPECIFICATION. B. CIRCUIT EXIT SIGNS 'E2 AND BUG—EYE 'E4' FIXTURES TO 2P1-38. C. ALL LUMINAIRES WITH (EM) DESIGNATION: PROVIDE ONE LAMP ON EMERGENCY BATTERY BACK—UP WITH A MINIMUM OF 1200 LUMENS. 111 : I SHEET KEYNOTES ROUTE VIA DIMMING CONTROL PANEL '1...CP1'. EACH ZONE CORRESPONDS TO A RELAY BRANCH. EACH BRANCH CIRCUIT CORRESPONDS TO A MODULE. EACH MODULE CONTAINS UP TO 4 RELAY BRANCHES (ZONES), 1800W MAX TOTAL FOR EACH MODULE. I i • . ' r ...... .. ....... -; ..... PROVIDE LUTRON OR APPROVED SWITCH FOR SCENE CONTROL OVERRIDE. INCLUDE BUTTONS FOR "HOUSEKEEPING", "LUNCH", "DINNER", AND "OFF". C REVIEvvED FOR E COMPLIANCE NFPA 70 - NEC iiiA( 2 2 2009 1192 WA, CitifOr kwila JUILDING DIVISION FILE COPY Permit No.11.1 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance Receipt of approved Field Copy and conditir is eclair wledged. By Date: _ City Of Tilkwila BUILDING DIVISION -B 1 RECEIVED rrry or rtn<witA MAY 18 2009 PERMIT CENTER Contact Mark O'Leary Project 2008-0497 INTERFACE ii ENG,NEERING 708 SM. 3RD AVE., Ora /.00, PORTLAND, OR 97204. PHONE 503.382.2266 FAX 503.382.2262 1 11 l.111 1 S:t P1:1111a,„.„!, 20 THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUIONLA, WASI-ONGTON REVISIO\ oIi SECOND FLOOR PLAN — LIGHTING Job No: 0826 File Name: Date: Rev: 1111111■I 05/06/09 /1\ CITY REVIEW COMMENTS CI TY REVISIONS 100AS 100A DUAL ELEMENT FUSES, BUSSMANN POWER MODULE SWITCFI INE TYPE LEGEND NEW EXISTING TO REMAIN EXISTING TO BE REMOVED ELEVATOR 15 -2OHP 1003 PROVIDE FEED -- THROUGH LUG PROVIDE FEED - THROUGH LUG 'LCP1' SHEET KEYNOTES EXISTING MC FEEDER ROUTED TO ABOVE CEILING IN TENAN SPACE. VERIFY LOCATION IN FIELD, PROVIDE DIMMING CONTROL PANEL. REFER TO SHEET E2.11 AND E2.12 FOR CONTROL ZONES. EACH ZONE IS CIRCUITED TO A RELAY BRANCH. EACH MODULE CONTAINS 4 RELAY BRANCHES. EACH MODULE IS POWERED BY ONE 20A CIRCUI FROM PANEL '2P1'. SET SCENES FOR HOUSEKEEPING, LUNCI DINNER AND OFF HOURS. VERIFY TIME SETTINGS WITH OSF PROJECT MANAGER. PROVIDE WITH INTEGRAL TIMECLOCK AN SWITCH CONTROL IN SECOND FLOOR OFFICE (SEE SHEET E2.02). COPPER FEEDER SCHEDULE 1003 3 #2 CU THWN -2, 1 #8 CU GND., IN 1 -1/4" C. #3/0 cu THWN -2. 1 #6 CU CND„ IN 2'l C. PANEL PANEL '2K1' '2K2` PANEL '2P1' . 2004 2004 (E) _...--.....-„,..-„,„--..---C - l.J(L) 20C}4 E EXTEND TO (E) MC FEEDER IN BUILDING MAIN ELECTRICAL ROOM .-"-._. •'"',..-r+...-.f".._.✓w.....n_...,,,/ --__ • (N) ) 200A 3P 2004 PANEL '2J1' E0.01 2004 2004 Li(E) F.J.l (F) E E (TYPICAL OF 4) wr SPARE ) (E) 200A 3P (E) 200A 3P (E) 200A ) 2 0A 3P 3P NEUT BUS NEW 2 -GANG METER STACK (5) COMP' E PCIAI._ METER CEN ILR FIJI I_ i FN0 TH GROUND BUS 1 ONE -LINE DIAGRAM NO SCALE ^, �,,,' v`,.'-• v--'•,.--` �,•-° �-. f• v.-.• v".- ai`"'-„-•-^, r- �, �" �o", �,'.'.' u°-... �--, r•, r'•-,/--,.-°.,.-•-ti.- �, r- �!•-- ,r- ti.r'•-,/V-rF--1/�,- -- •�„-�V AVAILABLE FAULT AT COMM. MTR. CENTER: 35,60 AVAILABLE FAULT AT TRANSFORMER: 39,700A A Panel '2 2" 120/208V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panel oard 200A Bus with Main Lug Only / Available Fault: 9763A RMS 08 -497 OSF TUKWILA Ckt. No. Description / Location Load (VA)lType C.B. A /Pole Note Ph. Note C.B, A /Pole Loud (VA)IType Description / Location Ckt. No. 1 AC -1 6,444 M 80/3 - A SPARE 'SPARE 2 4 3 -®- SPACE 2 3 6 •- -- 6,444 M - , B - 6,444 M -- SPACE 4 C 20/1 7 -• --- SPARE SPACE 6 - -- 6,444 M -- STAIRS, 2ND FL CORRIDOR 7 AC - -5 4,476 M 50/3 GEF -1 A 8 - -- 6,444 M SPACE 8. 9 ----•- 4,476 M - - -- B 11 ''I'' - F 6444 M SPACE 10 11 ----- 4,476 M -• ._...- G 19 21 15/3 552 M SPACE 12 13 SPACE 3,264 M -- 100 -- HOT WELL A --' - - 552 M SPACE 14 15 SPACE ,14- •,r•.,- - 29 -• FOOD CUTTER C B -- 552 M -- SPACE 18_ 17 SPACE 113 10 I A C 15/3 552 M CEF -3 SPACE 18 SPACE SPACE 20 22 1 B 1,600 A 552 M --- -- 22 SPACE 20 21 SPACE 1 44b - MICROWAVE - - B M _---u 24 - SPACE 22 23 SPACE A K 15/1 528 c EF -1 26 27 - SPACE 24 25 SPACE 600 15/1 696 M A 28 29 - -- 2,407 M SPACE 26 27 SPACE 15/1 696 M EF•'3 B 31 R- ROOF ' `-�"' G SPACE 28 29 SPACE 50 M EF -4, 5, 6 32 C R- ROOF 720 R II= 20/1 SPACE 30 SPACE 32 20/1 SOLENOID VALVE A 36 31 ELEVATOR ROOM LIGHTING : IIIA L 33 ELEVATOR PIT LIGHTING AND RECEPT. 360 R 20/1 WH -1,2 / CP -1,2 B 37 SPACE MN 1111111 Load Description - Load p Type 0 General (Non- Continuous) L Lighting R Receptacles - to 10 KVA over 10 KVA K Kitchen H Heating M Motors LM Largest Motor WH Water Heater C Continuous General Loud SPACE 34 SPACE 36 36 ELEVATOR CAR LIGHTS 210 L 20/1 SPACE SPACE ..... 38 37 ELEVATOR (20 HT) 8,640 M 100/3 41 A - -- 8,640 M T- B 42 Total Total rota! Connected Load: Ph. A 21,661VA 182 Amps Panel Connected Load: 65.5 KVA 182.OAmPs Connected Load: Ph. B 22,039VA 184 Amps Sub -Fed Connected Load: 0.0 KVA 0.0 Amps Connected Load: Ph. C 21,619VA 180ArnPu Total Dstnetad Load 70.4 KVA 195.4 Accessories :Provide Fully Rated Breakers SPACE 40 41 - -- 8,640 M - C SPACE 42 Tote Connected Load: Ph. A 19,737 VA 164Amps Panel Connected Load: 59.4 KVA 165.1 Amps Tots Connected Load: Ph. B 19,920VA 166Amps Sub-Fed Connected Load: 0.0 KVA 0.0 Amps Tots Connected Load: Ph. C 19,770 VA 165Arnps Total Dofnand Load 66.0 KVA 183.3ArnPa Accessories :Provide Fully Rated Breakers FILE: 0497E5.01.DWG E5.01 EDIT: 5/6/2009 2: 25 PM BY ANNAS i PLOT: 5/6/2009 2: 34 PM BY ANNA SANDYS Panel '21v11' 120/208V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panelboard 200A Bus with Main Lug Only / Available Fault: 9763A RMS 08 -497 OSF TUKWILA Ckt. No. 1 Description / Location lllb eilEa i is rY ally. ear ells a1�4 Load • T ii. .M.1 6,444 ire .iii1F. M C.B. Pole �. 80/3 Note Ph, Note - C.B. A /Pole _. Load (VA)IType Description / Location Ckt. No. _ AC -2 A K K 20/1 - 3,000 3,000 3,000 SPARE 'SPARE 2 4 3 -®- 6,444 M - --•- B 2 - ICE MAKER / BIN 20/1 , 6 - 6,444 M -- 2,100 C -- 20/1 7 -• --- SPARE 6 7 AC -3 6,444 M 80/3 STAIRS, 2ND FL CORRIDOR A * ** SPACE FOR SHUNT TRIP * ** 15/3 900 M GEF -1 8 8 - -- 6,444 M - 240 8 49 - FLOOR KETTLE - 900 M - -- 10 11 ''I'' - F 6444 M - C A * ** SPACE FOR SHUNT TRIP * ** - 900 M ._...- 12 19 21 15/3 552 M GEF -2 14 15 ' -'--- 3,264 M -- 100 -- HOT WELL B --' - - 552 M --- -- 16 vim --,---v- ,r ,°,� ,,,- ' ,14- •,r•.,- - 29 -• FOOD CUTTER C K -- 552 M -- 18 2,100 SPACE - -- 113 10 I A K 15/3 552 M CEF -3 29 21 SPACE * ** SPACE FOR SHUNT TRIP * ** 20 22 1 B 1,600 - 552 M --- -- 22 2$ SPACE 68 - FUTURE EQUIPMENT 24 26 1 44b - MICROWAVE - - 552 M _---u 24 - • - - '-- .-- 2,407 M 35/3 ) A K 15/1 528 M EF -1 26 27 - 2,407 M -- 1 B 600 15/1 696 M EF -2 28 29 - -- 2,407 M - 1 c 46 - BRAISING PAN 15/1 696 M EF•'3 30 31 R- ROOF ' `-�"' G * ** SPACE FOR SHUNT "TRIP * ** 79, 80 - FIRE SUPPRESSION SYSTEM A 35 15/1 50 M EF -4, 5, 6 32 33 R- ROOF 720 R 20/1 20/1 B 20/1 60 G SOLENOID VALVE 34 36 SPACE : IIIA 20/1 20/1 20/1 360 M WH -1,2 / CP -1,2 36 37 SPACE Accessories: - - Provide Feed -Thru Luce Load Description - Load p Type 0 General (Non- Continuous) L Lighting R Receptacles - to 10 KVA over 10 KVA K Kitchen H Heating M Motors LM Largest Motor WH Water Heater C Continuous General Loud Connected Subfed Total Demand Demand Loads Loads (S) Loads Factor Load 0.12 0.00 0.12 100% 0.12 (KVA Typical) 1.00 1.92 2.92 125% 3.65 0.00 1.80 1.80 100% 1.80 0.00 0.00 50% 0.00 48.83 30.31 79.14 65% 51.44 0.00 3.00 3.00 100% 3.00 0.00 7.91 7.91 100% 7.91 0.00 2,70 2.70 125% 3.38 0.00 0.00 0.00 125% 0.00 0.00 0.00 0.00 125% 0.00 To 71,30 KVA A 20/1 SPARE 39 SPACE 20/1 SPARE 40 41 SPACE . . C 20/1 SPARE 42 Total Total rota! Connected Load: Ph. A 21,661VA 182 Amps Panel Connected Load: 65.5 KVA 182.OAmPs Connected Load: Ph. B 22,039VA 184 Amps Sub -Fed Connected Load: 0.0 KVA 0.0 Amps Connected Load: Ph. C 21,619VA 180ArnPu Total Dstnetad Load 70.4 KVA 195.4 Accessories :Provide Fully Rated Breakers Load Load Description Connected Subfed Type Loads Loads (S) 0 General (Non- Continuous) 0.06 0.00 L Lighting 0.00 0.00 R Receptacles -• to 10 KVA 1.44 0.00 over 10 KVA 0.00 K Kitchen 0.00 0.00 H Heating 0.00 0.00 M Motors 44.69 0.00 LM Largest Motor 19.33 0.00 WH Water Heater 0.00 0.00 C Continuous General Load 0.00 0.00 Total Loads 0.06 0.00 1.44 0.00 0,00 0,00 44.69 19.33 0.00 0.00 Demand Demand Factor Load 100% 0.06 (KVA Typical) 125% 0.00 100% 1.44 50% 0.00 100% 0.00 100% 0.00 100% 44.69 125% 24.17 125% 0,00 125% 0.00 To 70,, 5 KVA_,, Panel 12K1' 120/208V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panelboard 200A Bus with Main Lug Only / Available Fault: 9763A RMS 08 --•497 OSF TUKWILA Ckt. No. Description / Location Load (VA)1Type C.B. A /Pole Note Ph. Note C.B. A /Pole Load (VA)IType Description / Location Ckt. No. 1 1 - ICE MAKER / BIN 863 863 K K 20/2 _ - 3,000 3,000 3,000 4 30/3 - 2,100 2,100 K K 48 - 12 GAL, KLIILE ON STAND -_-- 2 4 0 --•- 5 2 - ICE MAKER / BIN 1 ,608 K 20/3 96 - PLATE FREEZER Q MI 10 7 - 2,100 K -- 8 7 -• --- 1,608 K - SIGNA(;E 15/1 16 c STAIRS, 2ND FL CORRIDOR 20/1 * ** SPACE FOR SHUNT TRIP * ** 9 12 1,608 K - 1 912 1,722 B 20/1 20/1 20/1 15/1 240 K 49 - FLOOR KETTLE 19 11 8 - DISH MACHINE 2,364 K 45/3 - -- 792 25 - -1,000 c * ** SPACE FOR SHUNT TRIP * ** 12 13 _ -- 2,364 18 19 21 - -- 88 - FREEZER EVAPORATOR COIL n.. ®_- 792 915 915 M M 20 1 1,691 819 1,748 L 50, 73, 1102 - HOOD LIGHTING 14 15 - -- 100 -- HOT WELL 20 --' - R- 2ND FL COMP. ROOM, CONV. 23 20/1 20/1 30/3 2,100 K 61 - 12 GAL. KETTLE ON STAND 16 17 29 -• FOOD CUTTER 1,920 K 25/1 �* A 101 - HOT WELL - 2,100 K - -- 113 10 42 - HOLDING CABIN Er 2,300 K 25/1 M A IIIMIIIIIIIIIIIIIIIIII - 35/3 2,100 3,333 K K K * ** SPACE FOR SHUNT TRIP * ** 20 22 21 44a - MICROWAVE 1,600 K 20/2 23 - -- 1,600 1,600 K K -- 20/2 68 - FUTURE EQUIPMENT 24 26 25 44b - MICROWAVE - --- 27 -- 1,600 K - 20/1 B 40 - 3,333 K - -- 28 29 45 - CONVECTION OVEN W/ WORKTOP 528 K 15/1 Q ;PARE 20/1 600 K * ** SPACE FOR SHUNT TRIP * ** 30 31 * ** SPACE FOR SHUNT TRIP * ** Connected Connected Totes Demand SPARE 70 - FUTURE EQUIPMENT 32 33 46 - BRAISING PAN 1500 K 20/1 Load: 38.4KVA 106.8 Amps Loud: 0.0KVA O.OAmps Load 43.2 KVA 1 ArnPe Notes: 1. PROVIDE HANDLE -TIE FOR MULTI -WIRE BRANCH CIRCUIT, Load Load Description Connected Subfed Total Demand Demand Type Loads Loads (S) Loads Factor Load 0 General (Non- Continuous) 0.00 0.00 0.00 100% 0.00 (KVA Typical) L Lighting 21.85 0.00 21.85 125% 27+32 R Receptacles - to 10 KVA 13,17 0.00 10.00 100% 10.00 over 10 KVA 0.00 3.17 50% 1.59 K Kitchen 0.00 0.00 0.00 100% 0.00 H Heating 0.00 0.00 0.00 100% 0.00 M Motors 0-00 0.00 0.00 100% 0.00 LM Largest Motor 3.17 0,00 3.17 125% 3.96 WH Water Heater 0.00 0.00 0.00 125% 0.00 C Continuous General Load 0.25 0.00 0,25 125% 0.31 Tote) 43.17 KV • 20/1 120 G * ** SPACE FOR SHUNT "TRIP * ** 79, 80 - FIRE SUPPRESSION SYSTEM 34 36 35 *** SPACE' FOR SHUNT TRIP * ** 37 SPARE 20/1 20/1 SPARE 33 39 .SPARE 20/1 : IIIA 20/1 20/1 SPARE SPARE 40 42 41 SPARE m rota Connected Load: Ph. A 17,868VA 149ArnPs Iota Connected Load: Ph. B 16,408 VA 137 Amps Total Connected Load: Ph. C 15,673 VA 131 Amps Panel Connected Load: 49.9 KVA 138,7 Amps Sub -Fed Connected Load: 47.6KVA 132.3Amps To1aJ Dotnand Load 71.3 KVA 198.0AW Accessories: - - Provide Feed -Thru Luce Load Description - Load p Type 0 General (Non- Continuous) L Lighting R Receptacles - to 10 KVA over 10 KVA K Kitchen H Heating M Motors LM Largest Motor WH Water Heater C Continuous General Loud Connected Subfed Total Demand Demand Loads Loads (S) Loads Factor Load 0.12 0.00 0.12 100% 0.12 (KVA Typical) 1.00 1.92 2.92 125% 3.65 0.00 1.80 1.80 100% 1.80 0.00 0.00 50% 0.00 48.83 30.31 79.14 65% 51.44 0.00 3.00 3.00 100% 3.00 0.00 7.91 7.91 100% 7.91 0.00 2,70 2.70 125% 3.38 0.00 0.00 0.00 125% 0.00 0.00 0.00 0.00 125% 0.00 To 71,30 KVA Panel 12K2' 12O/208V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panelboard 200A Bus with Main Lug Only / Available Fault: 9753A RMS 08 -497 OSF FIJKWfLA Ckt. No. 1 Description / Location 71 - CONVECTION OVEN Load (VA)IType 888 K C.B. A /Pole 15/1 Note Ph. A Note um C.D. A /Pole IIMI - Load (VA)1Type 2,160 K Description / Location Ckt. No. 95 - SANDWICH GRILL 2 3 4 ** SPACE FOR SHUNT TRIP * ** 3,000 3,000 3,000 4 35/3 SPARE B C A B 2,160 K ---- Q R-- KITCHEN CONY. 72 - STEAMER 20/1 1,020 M 96 - PLATE FREEZER Q MI 10 7 - -- 20/2 - 1,600 1,600 K K 97 - MICROWAVE OVEN -. - 9 - -- 11 128 -- FREEZER - U/C DESSERT 600 SIGNA(;E 15/1 16 c STAIRS, 2ND FL CORRIDOR 20/1 1,080 M 98 - REFRIGERATED SANDWICH TBL 12 13 81, 82 - WALK-1N COOLER LTG, COIL 718 792 1 912 1,722 20 1 20/3 20/1 20/1 20/1 A B B N 20/1 20/1 1,000 1 ,000 H H EDH -1 - ,--- -- 1B 15 83 - CONDENSING UNIT COOLER B - -- 792 25 - SPARE c 27 20/1 1,000 H -- 18 19 21 - -- 88 - FREEZER EVAPORATOR COIL n.. ®_- 792 915 915 M M IM -• 1,691 819 1,748 A B C III 20/3 -- 1,236 1,236 K K 100 -- HOT WELL 20 --' - R- 2ND FL COMP. ROOM, CONV. 23 20/1 20/1 - 20/3 - -•- 20/1 20/1 20/1 1,236 1,740 1,740 K K K K -- WEST DINING, ZONE: 1,20,21,30 25 27 90 - CONDENSING UNIT - FREEZER �--- 900 900 900 1,200 2,0401 666 MAIN STAIR, DINING, ZONE: 17,19,23,24 15/3 - - 20/1 25/1 �* A 101 - HOT WELL 26 - -- 2S 2'9 - -- - -- 1 S r FL N, MAIN DINING, ZN: 2,3,16,18 31 9I - -- REFRIGERATED SALAD PREP TBL 1,080 720 R R 1 1 4a,b,c,d,e,f - POS SYSTEM & PRINTE`._ 116a,b,c,d - PRINTERS SPARE - SPARE 30 93 - BREAD WARMER WELL D 38 36 94 - OVERHEAD FOOD WARMER 37 - - -- 666 K 20/1 36 38 PARF ,... 20/1 20 1 20/1 20/1 250 C SPARE 39 25 -- AIR CURTAIN 408 1,200 M L 20/1 20/1 20/1 B 0 20/1 um 20/1 20/1 20/1 SPARE SPARE 40 41 87 - WALK -IN FREEZER Total Total Total Connected Load: Ph. A 16,980VA 142Amps Panel Connected Load: 47.6 KVA 132.3 Amps Connected Load: Ph. 6 16,511VA 138 Amps Sub-Fed Connected Load: 0.0KVA 0.0 Amps Connected Load: Ph. C 14,149 VA 1 18Arnps Total Demand Load= Refer to Section 1 Panel 120/208V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panelboard 200A Bus with Main Lug Only / Available Fault: 9763A RMS 08 -497 OSF TUKWILA Ckt_ No. 1 Description / Location SPARE �. y...� �. Load A T -.e • + i 900 ■i . ami "' C.B. A P le 20/11 20/1 Note t r 1 11011HE MI Ph. • = E Note EllE C.B. A /Pole 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 Load (VA)IType 720 720 7201 900 540 iR- 390 540 1,400 940 R R R � R R R R Description / Location Ckt. No R- VESTIBULE HOSTESS 2 20/3 SPARE R- VEST., BAR SEATING / V, S. SEATING 4 20/1 SPARE 20/1 • +` 20/1 R- S. SEATING, N. SEATING 2 3 „r. ; R-- KITCHEN CONY. 8 9 WINDOW SIGNAGE R -- KITCHEN , ADDITIONAL SEATING 10 11 WINDOW SIONAGE 900 1,200 1.200 770 1,364 129a - FREEZER - ICE CREAM 129b - FREEZER --- ICE CREAM ---ii- 20/1 20/1 20/1 20/1 20/1 ADNL SEAT., BAR SEAT., CORRIDOR 12 . SIGNAGE R- KITCHEN CONV., BUZZER 14 1,320 624 SIGNA(;E R- KITCHEN CONV. 16 STAIRS, 2ND FL CORRIDOR R- 2ND FL RR, MECH., EMPLOYEE TBL 18 - 2ND FL BACK ROOMS R- 2ND FL CONV, RR, STRO. 20 21 1ST FL KITCHEN NORTH 1 912 1,722 L L 20/1 20/1 20/1 - B N ��,+,,,, 20/1 20/1 20/1 --Q 360 ��SPARE M M M K R-- 2ND FL COMP, ROOM 22 R K 1ST FL. KITCHEN SOUTH r . 1. R 142a - COFFEE BREWER 25 ENTRY, ZONE: 13,14 SPARE 26 28 27 BAR, ZONE: 4,5,6,7,8 1,778 1,570 L 20/1 20 1 213 BANQUET, ZONE: 9,10,12 1.840.pds •B�AF4 -^ - -^- - 0'. 22 BANQUET, RR, ZONE: 11,25,29,31 1,691 819 1,748 - -- 20/1 20/1 20/1 - -- - ® 20/1 20/1 20/1 720 360 360UR 700 R R L R- 2ND FL COMP. ROOM, CONV. 32 20/1 20/1 2ND FL DINING, ZONE: 22,26,27,28 R- MUSIC SYSTEM 34 SPARE WEST DINING, ZONE: 1,20,21,30 -- TELEPHONE TERMINAL BOARD 36 117a - OVERHEAD FOODWARMER MAIN STAIR, DINING, ZONE: 17,19,23,24 1,449 35/2 20/1 C 20/1 20/1 20/1 20/1 EXIT SIGNS 38 37 1 S r FL N, MAIN DINING, ZN: 2,3,16,18 1,238 A B c 20/ 1 150a - CARBONATORS 0 SPARE 20/1 800 L L- EXTERIOR EGRESS 40 163 - GLASS BRUSH 1ST FL S DINING, ZN: 15 1,290 - 20/1 36 38 PARF ,... 20/1 20 1 20/1 20/1 250 C CONTACTOR, DIMMING CONTROL 42 L- KABOOSE 300 40 20/1 SPARE 20/1 20/1 SPARE SPARE 44 Connected Load: Ph. A Connected Load: Ph. B Connected Load: Ph. C TELEPHONE TERMINAL BOARD 360 1,056 1,056 1,056_ 14.052 11,973VA 12,416VA VA 20/1 15/3 - - 117 100Arnps 103A0.1ps iming. 111111311111 Amps 1111111 20/1 20/1 20 1 20/1 Panel Sub-Fed ;PARE 46 MAU -1 S (PARE 48 - - Connected Connected Totes Demand SPARE 50 -- SPARE 62 Total Total Total Connected Load: Ph. A Connected Load: Ph. B Connected Load: Ph. C Load: 38.4KVA 106.8 Amps Loud: 0.0KVA O.OAmps Load 43.2 KVA 1 ArnPe Notes: 1. PROVIDE HANDLE -TIE FOR MULTI -WIRE BRANCH CIRCUIT, Load Load Description Connected Subfed Total Demand Demand Type Loads Loads (S) Loads Factor Load 0 General (Non- Continuous) 0.00 0.00 0.00 100% 0.00 (KVA Typical) L Lighting 21.85 0.00 21.85 125% 27+32 R Receptacles - to 10 KVA 13,17 0.00 10.00 100% 10.00 over 10 KVA 0.00 3.17 50% 1.59 K Kitchen 0.00 0.00 0.00 100% 0.00 H Heating 0.00 0.00 0.00 100% 0.00 M Motors 0-00 0.00 0.00 100% 0.00 LM Largest Motor 3.17 0,00 3.17 125% 3.96 WH Water Heater 0.00 0.00 0.00 125% 0.00 C Continuous General Load 0.25 0.00 0,25 125% 0.31 Tote) 43.17 KV • Panel '2J1' 120/206V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panelboard 200A Bus with Main Lug Only / Available Fault: 9763A RMS 08 -497 OSF TUKWILA Ckt. No. Description / Location Load (VA)IType C.B. A /Pole Note Ph. Note C.B. A /Pole Load (VA)IType Deseri i ton P / Location Ckt. No. 1 99a - HEATED WORK CABINET 1,354 K 20/3 � - A 111 M 20/1 1,020 M 125 - FREEZER 2 3 -- 1,354 E mg IMMO 1,354 111111 mum 480 816 660 K K K El K M M Mil 20/3 20/1 20 /1 20/1 lunal 15/1 I B c A B 6 20/1 20/1 1,320 1,320 129a - FREEZER - ICE CREAM 129b - FREEZER --- ICE CREAM ---ii- 4 5 .. 180 -HOT WELL 99b - HEATED WORK CABINET 20/1 15/2 1,320 624 K 131 - FREEZER - ICE CREAM 8 -- 134a, b - SOUP WELL 10 - C A B C 14 - 624Q 360 R - -- 12 SPARE SPARE SPARE SPARE 20/1 137, 138 - TEA BREWER, MILK DISP. 14 M M M K 20/1 30/2 540 1,800 R K 139a, b, 140 - DISPENSERS 16 142a - COFFEE BREWER 15 22 106a, b - PASTA COOKER A B c SPARE - 30/2 -- 1,800 1,800Q1426 1,800U 864 864146 900 1,440 K M - 20 SPARE 108 - WORK TOP FREEZER - COFFEE BREWER 22 109 - REACH -IN REFRIGERATOR - -- 24 - -- SPARE _111 20/1 20/1 30 32 A 203 - GLYCOL SYSTEM 20/1 20/1 145 - COOLER - RED WINE - COOLER WHITE WINE 149 - BACK BAR COOLER 26 28 30 SPARE B 35 fa 117a - OVERHEAD FOODWARMER 3,150 K 35/2 El C 20/1 20/1 20/1 _ -� 3,15OQ 3,150 3,150 37 - 111111111 A B c 20/1 20/1 20/1 150a - CARBONATORS 32 SPARE 117b - OVERHEAD FOODWARMER 39 20 1 20/1 20/1 1,320 360 720 360 HR • 163 - GLASS BRUSH 34 a-.- 39 - R - BAR CONV. RECEPTACLE R - BAR CONV. RECEPTACLE 36 38 PARF ,... 20/1 20 1 20/1 - A SPARE B c 20/1 R - BAR CONY. RECEPTACLE 40 SPARE 20/1 SPARE 42 Total Total Total Connected Load: Ph. A Connected Load: Ph. B Connected Load: Ph. C 13,862VA 116 Amps Panel Connected Load: 43.8KVA 121.8Amps 13,502 VA 113 Amps Sub -Fed Connected Load: ' 5,.; . Arms 16,472 VA 137Amps Totes Armand Load 44.0 KVA 122.4 AMP, _ - _ Accessories: .....,_^..._^ Provide Feed -Thru Luis Load Load Description Connected Subfed Total Demand Demand Type Loads Loads (S) Loads Factor Load G General (Non- Continuous) 0.00 0.00 0.00 100% 0.00 (KVA Typical) L Lighting 0.00 0.00 0.00 125% 0.00 R Receptacles - to 10 KVA 2.34 0.54 2.88 100% 2,88 over 10 KVA 0.00 0.00 50% 0.00 K Kitchen 32.41 11.97 44.38 65% 28.85 H Heating 0.00 0.00 0.00 100% 0.00 M Motors 9.08 1.44 10.53 100% 10.53 LM Largest Motor 0.00 1.44 1.44 125% 1.80 WH Water Heater 0.00 0.00 0.00 125% 0.00 C Continuous General Load 0.00 0.00 0.00 125% 0.00 T t 44. 5 KVA 1��,nel '2w,12' 120/208V, 3 Ph., 4 W. Flush Mounted, Lighting & Appliance Branch Panelboard 200A Bus with Main Lug Only / Available Fault: 9763A RMS 08 -497 OSF TUKWILA Ckt. No. Description Location Load (VA)IType C.B. A /Pole Note Ph. Note C.B. -.: Load (V.AgType-ko Description / t:P ,--„. , -- ,-- ,,,-- .,f -- -,r- ,f-- „- -•,,,�,� CC . 1 SPARE 11.1■ 696© 750 500 996 360 180 1,800 1,800 1,440 1,440 416 718 718 1,800© 1,440 K K K " K K 20/1 15/1 20/1 15/1 15/1 20/1 20/1 30/2 - 20/1�� 20/1 20/1 . 20/2 MIN 20/1 20/1 � - 116111 1E1.11 H.,„.., non B El • A 111 M 20/1 20/1 20/1 20/1 , 20/1 20/1 33D M FREEZER 2 3 166 -GLASS FRO5TER SPARE 4 I68 OASIS MACHINE SPARE 6 7 179 - OVERHEAD FOODWARMER SPARE 5 .. 180 -HOT WELL .f.'` .� ,`.r`.,.�.. ..�.,.... „ 19 184, 188 LEMONADE, SODA DISP, SPARE 12 13 186 -TEA BREWER SPARE 14 15 17 19 187 - COFFEE BREWER -- - 190a REMOTE CARE30NATORS 20/1 20/1 20/1 20/1 20 1 20/1 20/1 SPARE 16 SPARE 18 M M M K SPARE 20 21 1906 - REMOTE CARBONATORS SPARE 22 23 SPARE SPARE 24 25 198, 199 -BEER COOLER, EVAPOR. 200 - BEER COOLER CONDENSER SPARE 26 27 SPARE 28 29 - -- 20/1 20 1 20/1 SPARE SPARE 30 32 31 203 - GLYCOL SYSTEM 33 204 - BOOSTER HEATER SPARE 34 35 SPARE III . - 20/1 20/1 20/1 20/1 El 20/1 SPARE 36 37 SPARE 111111111 20/1 20/1 20/1 SPARE 38 39 SPARE SPARE 40 41 SPARE SPARE _ 42, Total Tots Tata Connected Load: Ph. A 4,666VA 39Amps Connected Load: Ph. B 7,090 VA SgAmPs Connected Load: Ph. 0 3,628VA 30AmPS Panel Connected Load: 15.4 KVA ^ 42,7Amps ._ Sub -Fed Connected Load: U.OKVA O.OAmps Tote) Deeriand Load: Refer to Section 1 PANEL SCHEDULE 2M1 2P1 2K1 2J1 2M2 2K2 2J2 CODE COMP CE NFPA70 -NEC hiAr 21G9 City 'icwlla -ROWING DIVISION' RECEIVED rrry r,e TUKVVitA MAY 1 8 2009 PERMIT CENTER INTERFACE E NGINEER 1 N 5 Contact Mark O'Leary Project 2008,-0497 708 S.W. 3RD AVE., SUi'f1: 400, PORTLAND, OR 972(3.{ PUONE, 503.382.2266 FAX 503.382.2262 THE OLD SPAGHETTI FACTORY SOUTHCENTER SQUARE TUKWLA, WASHINGTON ONE LPE DIAGRAM, PANEL SCFEDULES ELECTRICAL Job No: 0826 File Name: Date: Rev: 05/06/09 BEVSIM N0;? CITY REVIEW COMMENTS CITY REVISIONS ELO8 ILI (8 Sheet No E..500 A -TO MOTOR TO OTHER HOOD EXFIAUST FANS A HOOD EXHAUST - FAN STARTER ELEVATOR CAR .�...- ELEVATOR MACHINE ROOM ELEVATOR SHAFT 14 II } \---- 5 TYP. ELEVATOR LOBBY r [ELEVATOR CON TROLLER DRIVE TO FIRE ALARM SYSTEM ELEVATOR LOBBY 2M2 -33 HOOD FIRE SUPPRESSION I SYSTEM E ELEVATION NEUTRAL PHASE e NOTE I THIS DETAIL eD MOUNT WEATHERPROOF TOGGLE SWITCH FOR PIT LIGHTING CIRCUIT BY TOP OF PIT LADDER. C2) PROVIDE SURFACE MOUNTED FLUORESCENT STRIPLIGHT. FOUR FOOT COLD ROLLED STEEL CHANNEL_ WHITE FINISH, WIREGE,JARD. LAMPS GUARDED WITH CLEAR PLASTIC SLEEVES. TWO 32 WATT TB LAMPS. LITHONIA C SERIES, METALUX, DAYBRITE, HUBBELL, LIGHTOLIER OR APPROVED. TYPICAL OF TWO. MOUNT ONE LUMINARIE ON THE FRONT ELEVATOR WALL, THE SECOND JN THE REAR ELEVATOR PIT WALL. AVOID LOCATING FIXTURES DIRECTLY BEHIND BEAMS OR STRUCTURE THAT WOULD BLOCK LIGHTING. 3 NOT USED. O MOUNT 135' FIXED TEMPERATURE HEAT DETECTOR TO WITHIN 24 INCHES OF EACH SPRINKLER HEAD IN ELEVATOR MACHINE ROOM AND HOISTWAY. MOUNT SMOKE DETECTOR IN ELEVATOR LOBBY ON CEILING WITHIN 21 FEET OF ELEVATOR DOOR. ELEVATOR FEEDER FROM POWER DISTRIBUTION PANEL CON TROL WIRING TO FIRE ALARM SYSTEM FUSIBLE SHUNT TRIP POWER MODULE BATTERY LOWERING DEVICE L ELEVATOR CONTROLLER/ DRIVE 10 t-'-1 O ' -- CONTROL SIGNAL FROM AUTOMATIC TRANSFER 5 2M2 -35. WIRING.. SCHEMATIC TO ITCH 1 HYDRAULIC TYPE ELEVATOR DETAIL ADDRESSABLE FIRE ALARM SYSTEM POWER PACK OVERRIDE (OFF) SWITCH LOCATED IN SAME SPACE AS LUMINARIES PROVIDE ONLY IF INDICATED ON PLANS LOW VOLTAGE CABLE FOR MANUFACTURER REQUIREMENTS TO NEXT REMOTE SENSOR IF REQUIRED 24VDC REMOTE SENSOR 2 OCCUPANCY SENSOR CONTROL DIAGRAM NO SCALE - TERMINAL - BLOCK HOOD CONTROLLER N0 ON COMMON OFF TO HOOD LIGHTS SHUNT TRIP BREAKERS OR CONTACTORS FOR LOADS UNDER CLASS I HOOD. TO OTHER ? ff II MAKE -UP AIR UNITS A MAKE -UP AIR - /.\ HANDLER STARTER GAS SOLENOID VALVE(S) ' '-- INCOMING FEEDER -- } TO MOTOR INCOMING FEEDER r s TO OTHER SHUNT -TRIP BREAKERS OR CONTACTORS SEQUENCE OF OPERATION 1. WHEN HOOD EXHAUST FAN(S) ARE STARTED THEN START MAKE AIR UNITS) 2. WHEN HOOD EXHAUST FAN(S) ARE STOPPED THEN STOP MAKE -UP AIR UNITS) 3. WHEN HOOD FIRE SUPPRESSION SYSTEM IS ACTIVATED THEN SHUT OFF MAKE UP AIR UNIT AND, TURN OFF EQUIPMENT UNDER CLASS I HOOD, CLOSE GAS SOLENOID VALVES AND SEND ALARM SIGNAL TO FIRE ALARM SYSTEM. 3 HOOD CONTROL AND FIRE SUPPRESSION WIRING DIAGRAM NO SCALE FILE: 0497E6.01.DWG - E6.01 I EDIT: 5/6/2009 10: 26 AM BY ANNAS ' PLOT: 5/6/2009 2:35 PM BY ANNA SANDYS 4 6 MOUNT SHUNT POWER MODULE TO WITHIN 24 INCHES OF STRIKE SIDE OF DOOR TO ELEVATOR MACHINE ROOM. 0 PROVIDE DEDICATED CIRCUIT. ROUTE INCOMING CIRCUIT TO LUMINARIES UPSTREAM OF GFCI RECEPTACLE IN FROTH MACHINE ROOM AND ELEVATOR PIT, PER N.E.G. ARTICLES 620.23 AND 620.24. PROVIDE FUSIBLE SHUNT TRIP POWER MODULE WITH CONTROL TRANSFORMER, TEST SWITCH, PILOT LIGHT, AUXILIARY CONTACTS AND ALARM CONTACTS. PROVIDE 200 AMP, 3 POLE APP SWITCH. ROVED BU. SSMAN, FERRAZ - SHAWMUT, LITTLEFUSE OR 0 PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER /DRIVE FOR ELEVATOR PRIMARY RECALL, SEE WIRING SCHEMATIC. 10 PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO SHUNT TRIP CONTROL OF ELEVATOR POWER, SEE WIRING SCHEMATIC. 11 ROOM LIGHTING, SEE FLOOR PLAN FOR TYPE, QUANTITY AND CIRCUITING. 12 PROVIDE SEPARATE DEDICATED CIRCUITS AND LOCKABLE CIRCUIT BREAKERS FOR ELEVATOR CAR LIGHTS AND HVAC, LOCATE IN ELEVATOR MACHINE ROOM NEAR ENTRY DOOR. PROVIDE A SIGN TO IDENTIFY THE LOCATION OF THE OVERCURRENT PROTECTIVE DEVICES. INDICATE TYPE OF LOAD NEXT TO EACH CIRCUIT BREAKER. 1 PROVIDE HEAT AND SMOKE DETECTORS AT THE TOP OF EACH ELEVATOR SHAFT, WHEN SPRINKLERED. CONNECT TO F.A. SYSTEM INITIATING DEVICE CIRCUIT. COORDINATE WALL MOUNTING SPACE FOR ELECTRICAL EQUIPMENT WITH ELEVATOR SUPPLIER /INSTALLER PRIOR TO ROUGH -IN. 16) PROVIDE DEDICATED PHONE LINE IN 3/4" C. TO TELEPHONE - TERMINAL BOARD. PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER TO ACTIVATE FIREMAN HAT LIGHT IN ELEVATOR CAB UPON INITIATION OF SMOKE DETECTION IN ELEVATOR SHAFT OR MACHINE ROOM. 18 CONNECT TO F.A. SYSTEM FOR MONITORING OF CONTROL POWER. PROVIDE ADDRESSABLE F.A. CONTROL RELAY AND WIRING TO ELEVATOR CONTROLLER FOR ELEVATOR ALTERNATE RECALL. SEE WIRING SCHEMATIC. L E G E N D 1- COPPER GROUND BAR 2- INSULATORS 3- 5/€" LOCKWASHERS 4- WALL MOUNTING BRACKET 5- 5/8-11 X 1" H.H.C.S.BOLTS 6- BARE COPPER GROUND CONDUCTOR TO MAIN SERVICE EQUIPMENT GROUND. REFER TO SPECIFICATIONS FOR CONDUCTOR SIZE. TELECOMMUNICATIONS MAIN GROUNDING BUSBAR (TMGB) DETAIL NO SCALE Kitchen Connection Schedule Item Description v 1 k +use Load Wire I Conduit Circuit otos 1 ICE MAKER /BIN 208/1 208/3 ,,.. 80 703 2M2- 1,3,5. ICE MAKER /BIN 208/3 Air Conditioning Unit 203 21(1- -5 7,9. 80 8 DISH MACHINE 208/3 19.7 FLA 303 208/3 63,7 MCA 5 AIR CURTAIN 120/1 3.4 A 202 Air Conditioning Unit 208/3 29 FOOD CWT R 120/1 1.0 HP 202 2K1 -17. Air Conditioning Unit 42 HOLDING CABINET 120/1 208/1 2.3 KW 3.2 KW 302 202 2K1 -19. 21(1- 2123. AC -6 44a MICROWAVE OVEN 44b MICROWAVE OVEN 208/1 3.2 KW 202 2K1- 25,27. Circulation Pump 5 CONVECTION OVEN w /WORKTOP 120/1 4 4 • • .. K1-29. 1 46 BRAISING PAN EXISTING) 1/12 Hp 20 202 21(1-33. 1,2 48 Electri.c...Duct_Heater 208/3 6.3 KW 303 2K1- 2,4,6. 2K2- 14,16,18. 49 FLOOR KETTLE 120/1 2.0 A +� .. K1 -10. 1 50 TYPE 1 HOOD 120/1 0.4 KW + ` K1 -14. 2K1- 16,18,20. LTS 61 12 GAL KETTLE ON STAND 208/3 6.3 KW 303 68 SPARE - FUTURE EQUIPMENT 208/3 10.0 KW 403 21{1- 24,26,28. 70 SPARE _- FUTURE EQUIPMENT 120/1 5.0 A 202 2K1 -32. 120/1 71 '. CTION OVEN 120/1 7.4 A 0 : ,- Exhaust Fan 72 ST ER 208/3 9.0 KW 403 .. 2K2- 5,7,9. EF -6 73 TYPE 1 HOOD 120/1 0.5 KW 202 K1-14, LTS 7 FIRE SUPPRESSION SYSTEM _ 120/10 120/1 120/1 120/1 yy 0_ .K1-- 6. 2M1- 8,10,12. 80 FIRE S PRESSION SYSTEM fi0 W 0.5 KW 202 202 2K1 --36. 2K2 -13, 15 81 WALK -°-I1, +OLER COOLER EVAPORATOR COIL 82 02 K2 -13, 83 CONDENSING UNIT - COOLER 208/3 1.5 HP 203 2K2-15,17,19, 208/3 1.0 HP WALK -IN FREEZER 120/1 208/1 1, K 8.8 A 02 2K2- 21,23. Make Up Air Unit 88 FREEZER EVAPORATOR COIL •0 C.NDEN'1NG UNIT - FREEZER 208/3 2.0 HP 03 2K2- 25,27,29, 1202.122225.p.0 91 93 F T .'_P PREP TABLE 120 1 10.0 A +. - Water Heater BREAD WARMER WELL 120/1 17.0 A 302 2K2 -33. 94 OVERHEAD FOODWARMER 208/1 6.4 A 202 ISMIIIIIIIIII 2K2 -2,42 95 SANDWICH GRILL 208/1 18.0 A 302 96 PLATE FREEZER 120/1 8.5 A 202 2K2 -6, Feeder Schedule 97 MICROWAVE OVEN 208/1 403 3 #8 CU THWN -2, 1 #10 CU CND., IN 3/4" C. 703 3 #4 CU THWN -2, 1 #8 CU GND., IN 1" C. 2K2 -8,10. 98 REFRIGERATED SANDWICH TABLE HEATED WORK CABINET 120/1 208/1 g 0 2,02 203 2K2 -12. 2J1- 1,3,5. 99a . . H 'T r •- ;; 208/1 .•, 2J1- 7,9,11. 100 HOT t _ L _. 208/3 10.3 A 203 2K2-- 20,22,24. 101 HOT WELL YPE 2 VAPOR HOOD 208/3 120/1 14.5 A 0.1 KW 203 202 21<2- 26,28,30. K1- 4. 102 106c PASTA COOKER 120/1 2.0 A 202 1066 PASTA COOKER 120/1 2.0 A 202 202 .J1 -1:. 2J1 -21. 108 WORK TOP FREEZER 120/1 ..8 A 109 REACH -IN REFRIGERATOR 120 1 02 2J1 --23. 14 POS SYS M .'I►1:.' 120/1 , a , . -32. 4 114b POS SYSTEM & PRINTERS 120/1 1.5 • 02 'K2 -32. 114c POS SYSTEM & PRINTERS 120/1 1.5 A 02 K2 -32. 114d P05 SYSTEM & PRINTERS 120/1 1.5 A 202 21{2 --32. 114e POS SYSTEM 8c P' R 120/1 1.5 A 202 21{2 -32. 114f POS SYSTEM & PRINTBR5 PRINTERS PRIERS PRINTERS PRINTERS 120/1 120/1 120/1 120 1 120 1 1.5 A 1.5 A 1.5 A . A L5 A 202 202 20, _ 02 202 2K2 -32. 21{2 -34, '- K` -34. _1(. - 4, 21{2 -34. 4 NI 116a 1166 116c 116d 117a OVERHEAD FOODWARMER 208/1 6.3 K 402 2J1- 29,31. 117• OV R H WARM 'R 208/1 120/1 ..7 K 8.5 A 402 202 2J1-33,35. 2J1-2. 125 .. FREEZER 128 FREEZER - UNDERCOUNTER DESSERT FREEZER - ICE CREAM 120/1 120/1 5.0 A 11.0 A 202 202 21{2 -11. 2J1 -4. 129a 129b FREEZER - ICE CREAM 120/1 11.0 A 202 2J1-6. 131 134a FR - I::. R. 120 1 1 .0 A 0 MilIMIIIIIIII 2J1- 10,12. SOUP W LL 208/1 3,0 A 202 1346 _._ SOUP WELL 208/1 3.0 A 202 2J1- 10,12. 13, 7 R MILK DISPENSER 120/1 120/1 1. A _ 1.5 A 202 202 J1 -14. 2J1 -14. 138 139a SODA DISPENSER 120/1 120/1 1.5 A 1. • 202 ' 02 .._ -16, 2J1-16. 1396 SODA DISPENSER 140 LEMONADE DISPENSER 120/1 202 2J1-16. 142b COFF.: R COFFEE BREW . 208/1 208/1 1 .0 A 303 2J1-- 18,20. 15.0 A 303 2J1-22 , 24 • 145 COOLER - RE I 120/1 7.2 A 202 2J1 -26. 146 COOLER - WHITE WINE BACK BAR COOLER 120 1 120/1 7,r A 7.5 A '.1 2' 1- .:. 149 2J -30. 150 CARBONATORS 120/1 12.0 A 0 IBM 2J1 -34. 163 GLASS BRUSH 120 1 11.0 . .02 166 GLASS FROSTER 120/1 5.13 A 202 2J2 -3. OASIS MACHINE (OWNER) , ... 2J2 -5. 179 180 OV RH.. r FOODWARMER 208/1 0.5 KW 202 2J2-7. _ HOT WELL 120/1 8.3 • 202 2J2 -9. s4 LEMONADE DISPENSER 120/1 120/1 :111 1.5 A _0_ 202 2J2 -17. 186 TEA BREWER 2J2 -13, 87 COFFEE BREWER 208/1 15.0 A 303 2J2- 15,17. 188 SODA DISPENSER 120/1 1.5 A 02 2J2 -11. 90a REMOTE CARBONATORS 120/1 12.0 A. . _ .202 1.: 202 2J2 -19. -. 1. MEM MI R . •T A' :ONATOR 120 1 12.0 A 19B BEER COOLER 120/1 0.2 KW 199 BEER COOLER EVAPORATOR 120/1 1.8 A 202 2J2 -25. •_0Q BEER COOLER CONDENSER (ON ROOF) 208 1 3/4 '0 2J2- 27,29. MI 203 GI210DL SYSTEM F.1 •c ER H 'TER 120/1 120/1 15.0 A 12.0 A 202 202 2J2-31 2J2 -33,._ NM 204 eral Kitchen Equipment Connection Schedule Notes A. Refer to kitchen consultant drawings for exact locations and connection types. Coordinate connection with supplied equipment and vendor drawings. lichen Eq4prnent Connection Schedule Notes 1 Provide shunt trip breaker. Interlock with fire suppression system. Refer to detail 3 / E6.01. 2 Verify requirements prior to rough -in. 3 Provide wire for 120V connection. 4 Route power via Point of Sale Hub. Maximum of 6 registers. upper Feeder Schedule 202 2 #12 CU THWN -2, 1 #12 CU GND., IN 3/4" C. 203 3 #12 CU THWN -2, 1 #12 CU GND., IN 3/4" C, 302 2 #10 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 303 3 #10 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 402 2 #6 CU THWN -2, 1 #10 CU CND., IN 3/4" C. 403 3 #8 Cu THWN -2, 1 #10 CU GND., IN 3/4" C. Mechanical qui r nt Connection Schedule Item Description Volte 1 Phase Gad -Y Wire/ -. -,r s,--. AC -1 Air Conditioning Unit 208/3 63.7 MCA 80 703 2M2- 1,3,5. AC -2 Air Conditioning Unit 20-B73-- 088 /3 63.7 MCA 80 703 2M1- 1,3,5.__ AC -3. Air Conditioning Unit 208/3 63,7 MCA 6 7032 2M1-7,9,1 AC-4 Air Conditioning Unit 208/3 - ,,- --,r,ty -v° 46-3. r--.22Fo11-vi3.r45,rhlr,r°2"Th` AC -5 Air Conditioning Unit 208/3 ,37,3 FLA 50 403 2M2'- .7,9,11. AC -6 Air Conditioning Unit 208/3 20.0 FLA 35 303 2M1- 25,27,29. OP -1 Circulation Pump 120/1 12 "may jp 20 202 241-36. CP -2 Circulation Pump 120/1 1/12 Hp 20 202 2M 1 -36. EDH° -1 Electri.c...Duct_Heater 208/3 3.0 KW 20 203 2K2- 14,16,18. EF -1 Exhaust Fan 120/1 1/5 Hp 15 202 2M1 -26. EF -2 _.... Exhaust Fan 120/1 1/4 HP 15 202 211_ -,28. - _EE-.; Exhaust Fan 120/1 1/4 HP 15 202 .....2M1 -30. F_F4 Exhaust Fan 120/1 50.0 W 15 202 2M1 -32. 2 EF-5 ,- Exhaust Fan 120/1 50,0 w 15 402 2M1 -32. 2 EF -6 Exhaust Fan 120/1 (y,0 W 15 202 2M1 -32. GEF -1 Exhaust_Fun 20813 2.0 HP 15 203 2M1- 8,10,12. GEF -2 ___ Exhaust Fan 208/3 1.0 HP 15 203 2M1- 14,16,18. GEF -3 Exhaust Fan 208/3 1.0 HP 15 203 2M1- 20,22,24. MAU -1 Make Up Air Unit 208/3 11.0 MCA 15 . 20:5 2P1- 37.39,41. ,.- WH--1 Water Heater 1202.122225.p.0 W 15 202 2M1 -36. WH-2 Water Heater _.____60.0 120/1 50.0 w 15 202 2M1 -36. General Mechanical Eqt iprnent Connection Schedule Notes The above information is for a specific manufacturer, Actual manufacturer for the equipment may be A different, Coordinate with mechanical equipment submittals for loads and over current protection requirements prior to installation of wiring. 8, MOCP = Maximum over current protection MCA = Minimum circuit ampacity Mechanical Equipment Connection Schedule Notes 1 Interlock with hood exhaust and fire suppression system, Refer to detail 3 / E6.01, 2 Interlock with lighting control in room. Copper Feeder Schedule 202 2 #12 CU THWN -2, 1 #12 CU GND„ IN 3/4" C. 203 3 #12 CU THWN -2. 1 #12 CU GND., IN 3/4" C. 303 3 #10 CU THWN -2, 1 #10 CU GND., IN 3/4" C. 403 3 #8 CU THWN -2, 1 #10 CU CND., IN 3/4" C. 703 3 #4 CU THWN -2, 1 #8 CU GND., IN 1" C. flREVJEWED FOR CODE COMPLIANCE IVFPA 70 - NEC CityOf Tukwila ,BUILDING DIVISION' RECEIVED C1YV OF TIJUWILA MAY 18 2009 REVS4N N Contact Mark O'Leary Project 2008 -0497 INTERFACE ENGINEER IPIG 708 S.W. 3R1) AVE., SIUITE 40o, PORTLAND, Ott 97204 PHONE 503.382,2 X66 FAX 503-382,2262 'ir 50'2..2:26 T ° E OLD SPAGHETTI FACTORY SOUTHOENTER SQUARE TUKWLA, WASHINGTON DETAILS, CONNECTION SCHEDULES ELECTRICAL Job No: 0826 File Name: Date: Rev: 05/06/09 CITY REVIEW COMMENTS CITY REVISIONS LOB I'IEB