Loading...
HomeMy WebLinkAboutPermit EL08-0151 - WESTFIELD SOUTHCENTER MALL - CHICKEN NOWCHICKEN NOW 2600 SC MALL FC 11 07-21-08 ELO8-151 CitAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -151 Issue Date: 06/10/2008 Permit Expires On: 12/07/2008 Tenant: Name: CHICKEN NOW Address: 2600 SOUTHCENTER MALL FC -11 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: BOB ROBINSON Phone: 253 - 677 -6874 Address: 37936 23 PL S , FEDERAL WAY WA Contractor: Name: C & R ELECTRIC INC. Address: 919 SW 150 ST , SEATTLE WA Contractor License No: CRELEI *415DW Phone: 206 937 -3654 Expiration Date: 03/31/2010 DESCRIPTION OF WORK: NEW ELECTRICAL TO INCLUDE HOOD, REFRIGERATION EQUIPMENT, LIGHTING AND MISCELLANEOUS ELECTRICAL Value of Electrical: $22,000.00 Fees Collected: $553.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wi wl%fiei ed herein or not. The granting of t construch' Signature: ••-s not pr- :umeto - o ork. c '� III _1011_1W., III Print Name: v7..."32C, 6:2-"e77-1/ ority to violate or cancel the provisions of any other state or local laws regulating ed to sign and obtain this electrical permit. Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -151 Printed: 06-10 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Tenant: CHICKEN NOW Permit Number: EL08 -151 Status: ISSUED Applied Date: 02/15/2008 Issue Date: 06/10/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe ..'t does not pres - e to give a ty to violate or cancel the provision of any other work or local laws regulatin • _ = tru • on or the perf • rmance of Signature: /ter Print Name: Date: doc: Cond -Elec EL08 -151 Printed: 06 -10 -2008 CITY OF TUKWIL. Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Electrical Permit No. ti--0 % S CO Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 59o1) 090 /or // Tenant Name: MA6(0— MorVG //,exe Alpri/ Property Owners Name: WtSTF( ErLD (DAP Mailing ) Mailing Address: (l (DD I W L514I 2e 13 W King Co Assessor's Tax No.: b 'T20 _D / D Suite Number: tC— I I Floor: New Tenant: Yes ❑..No inS 9n.E1.e5 City CA State �o0GC Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: 1398 Fe, Mon ( 17 -) Day Telephone: Mailing Address: ci 36 Z3rd PL • S. FEDePAL,Wkif INA cieDD3 City State Zip E -Mail Address: j) ('YY) l t4) It ocpr i(Lf • /'I d Fax Number: 2 S -66/ - 64x/ ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ '9_21 000 ( f Scope of Work (please provide detailed }formation): n � e 4r I ti �° �e Yp ' eQutf0, )1 -t ►/1c. rhr` ,e(e-eA1riczxr Will service be altered? ❑ Yes No Adding more than 50 amps? cg Yes ❑ No Type of Use: 1? . 41)Y/3'1- Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: XrPuget Sound Energy ❑ Seattle City Light HR Applications\Forms- Applications On Line'4 -2007 - Electncal Permit Apphmtion.doc bh Page 1 of 2 i RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. A- Vii; r E74 ,ice BUILDING OWNER OR ELECTRICAL CONTRACTOR Signature: 1411 Date: Print Name: 130,8 aR9 / tii�� (PeRMIT PL e) Day Telephone: Z7 7--64. 71fr Mailing Address:371369 Z33v ( P r S ' E12/1-L lV w qeD 3 City State Zip IDate Application Accepted: _ OQ Date Application Expires: ( S-_ OQ Staff Initials: l44 H:\Applications'Fonns- Applications On Lineal -2007 - Electrical Permit Application doc bb Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -151 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 02/15/2008 Applicant: CHICKEN NOW Issue Date: Receipt No.: R08 -02063 Initials: BLH User ID: ADMIN Payment Amount: $442.80 Payment Date: 06/10/2008 03:38 PM Balance: $0.00 Payee: C & R ELECTRIC INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 27065 442.80 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 442.80 Total: $442.80 3536 06/11 9711 TOTAL 442.80 doc: Receiot -06 Printed: 06 -10 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -151 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/15/2008 Applicant: CHICKEN NOW Issue Date: Receipt No.: R08 -00441 Payment Amount: $110.70 Initials: WER Payment Date: 02/15/2008 10:49 AM User ID: 1655 Balance: $442.80 Payee: HOSPITALITY INTERNATIONAL GROUP TRANSACTION LIST: Type Method Description Amount Payment Check 2537 110.70 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 110.70 Total: $110.70 P.172 02/15 ?710 TOTAL 975.80 doc: Receiot -06 Printed: 02 -15 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit A -I5t PERMIT NO. CITY OF TUKWILA BUILDING DIVISION = 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: cal dQ� czoti Type of Inspection: 2/01:) Address: � �� ilttki Date Called: Special Instructions: Date Wanted: Z I m P.m. Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: N cr'thik-T Inspector: Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ett,teselne6 _ .� - �- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project . <: (1 j G i /" ,U ) Type of Inspectioc .e,'� ,lac.% Addr ss: .-� 72 s")' A f �,a Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: ElApproved per applicable codes. or ctions required prior to approval. COMMENTS: ip..//)/2 Insp ctgr: ,0- -f/f,; /`/ Date' �/f ? /O' Ei $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit .T7 F��B- Is1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: not Type of Inspection: WOO Address: 7,o Date Called: Special Instructions: Date Wanted: t 1 112 a.m� `per Requester: Phone No: Approved per applicable codes. /1 Corrections required prior to approval. COMMENTS: 17A- 5-rocx /5-7-4f-f -t, 5 154 kcocitr attP P Jr (Je,t f&'LP, Ai- r u P - 5 /PPoe r rc4oJIr /rc_(r -r (.�1I u•Jr, pc o )1 ?n/ God Pe d) Inspector: 664Aleis Date: 0.30/0\Ir El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Ne' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: e , ` A%v+J �i t Ty pe of Inspection: .� o0 3 Address: �2 i Date Called: Special Instructions: Date Wanted: 7 p (,mom' ��-p Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspector: 1ti 6(4A)Cie. (Date: O7(i /c El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: .4 _t ... . INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit 1,01?- BSI PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: cal ce.c.4 40W Type of Inspection: /001-- Aq . Address: ZG I ao " 1�t� Date Called: _...�. Special Instructions: Date Wanted: f c3.4r Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: — k aaIE 604o141 ju s1 P6 1,4 PAilta. Inspector: &Alec, Date: 0? ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit VaA-/ 5-, PERMIT NO. (206)431 -3670 Project: GI /IC. iee-,v Ai O ' Type of Inspectio /O?53 Address: ;� tJ C1 C-- 41//1 Date Called: Special Instructions: Date Wanted: /.. , / .4.zpk Requester: Phone No: roved per applicable codes. 0 Corrections required prior to approval. OMMENTS: 2 5 #411-1 c-14 /64/ 77. Ad6f Inspect6 6 Date: . /.2 t/06. El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Li,.�sr a 4dr1.ss _ v r.� _1.ic ti... „ , r:►.., ....... +.sue ..rah... _. - •�. ' —.w� as...,.ti , a • r�.rt.'�SI INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 P cto4e� ,v0 'Type of Inspection: .� ri G /11/17e6i. Date Called: Special Instructions: Date Wanted: // (/ p.m. Requester: Phone No: ed per applicable codes. ❑ Corrections required prior to approval. MMENTS: /3%4 D,K —�✓�tt5 / //Mn yin Inspect •'��L irrWA/6y Date:6 /#0?... El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: rate: ••.7riakla .. �... .. .s. _... _amt .. . • . Al... A.ir_w.J 2006 Washin ton State Nonresidential Ener Code Com•liance Form • Interior Lighting Summary • LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forams Project Info Project Address CHICKEN NOW Date *FA) or &REA ptaippil CG l-1 NRA i r� R 1 , ,mot t? AM - NE O 0 633 SOUTHCENTER SPACE #CF11 SEATTLE, WA 98188 Applicant Name: 3421 N.LAKEVIEW DR BOBBY SABAS Applicant Address: TAMPA, FL 33618 Applicant Phone: 813-265-3955 819 KITCHEN CLG. HIGHT ABOVE 9' Project Description • New Building • Addition • Alteration K1 ans Inc f Tub C. Refer to WSEC Section 1513 for controls and commissionin• require s Compliance Option 0 Prescriptive b Lighting Power Allowance 0 S ', to ' (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) SALES Alteration Exceptions (check appropriate box - sec. 1132.3) 3 50 150 • No changes are being made to the lighting EMERGENCY LIGHT • Less than 60% of the fixtures new. installed wattage not increased, & space use not changed. 20 Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per fl2 "" Area in ft2 Allowed x Area SALES/ FAST FOOD ESTABLISHMENT 1.365 600 819 KITCHEN CLG. HIGHT ABOVE 9' 5 32 160 KITCHEN 2X4 FLUORECENT BOX "A" 4 64 256 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt 819 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES COMACT FLUORESCENT "E" 16 13 208 SALES LINEAR FLUORECENT "C" 5 32 160 KITCHEN 2X4 FLUORECENT BOX "A" 4 64 256 SALES INCAN. PENDANT LIGHT "F" 3 50 150 KITCHEN EMERGENCY LIGHT 2 20 40 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 814 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. FILE COPY EL..0B. I R-o..x:119w D FEB 15 2008 PEt-.lcrt I eENTEh 2006 Washin ton State Nonresidential Ener Code Com•liance Form • Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Lighting 0.9 o • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other" and Fixtures: 1.2 fixture answer is checked. the number of (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector fixtures in the space is not limited by Code. 1521) or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- Clearly indicate these spaces on plans. If not qualified. do LPA Calculations. 1.3 Ironic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 1.1 Dormitory 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballas Retail1', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA s Use' LPAZ (W /sf) Use' LPAZ (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 2:1' 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail1', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia', assembly spaces' 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet /conference/exhibition hall3 4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) , 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5.000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free-standing display where the lighting moves with the display are exempt. An additional 1.5 wfft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -151 DATE: 02 -15 -08 PROJECT NAME: CHICKEN NOW SITE ADDRESS: 2600 SOUTHCENTER MALL - FC -11 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPART ENTS: Bui ng Ii ision klit5 u Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 02-21 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03 -20 -08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electron or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License CRELEI *415DW Licensee Name C & R ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 600316021 Ind. Ins. Account Id Business Type CORPORATION Address 1 919 SW 150Th ST #A Address 2 City BURIEN County KING State WA Zip 98166 Phone 2069373654 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/16/1959 Expiration Date 3/31/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License GARTICW2537T Electrical Administrator Information License GARTICW2537T Name GARTIN, CECIL W Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date GARTIN, CECIL W 01/01/1980 GARTIN, MARC S 01/01/1980 GARTIN, REVA M 01/01/1980 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CRELEI *415DW 06/10/2008 - .._ ▪ -._._ an::::... `.. PANEL "H" PANEL "A" A -16(1) A -20(1) —_ TEL BD. "TTB" A -27,29 A -16(2) TYP P A -14 H -1,3,5 TYP 0U -1 (AT ROOF) R GA TYP ELECTRICAL O PLAN SCALE: 1 /4" = 1' -0" ....t�. .- • �••�� �� LCD T �� -� 11,1crRacar, NG PLAN SCALE: 1/4" = 1'--0" A -9 A -7 self service ordering FILE COPY Penult No. wappr�atts le gnat wof _n�gondoA menu _ ths *Mon ca any *Opted Olsond of Tukwila BULD%NG ENVISION NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot - candle illumination at the 6? floor along the entire egress pathway and exit discharge SEPARATE PERMIT REQUIRED filecItanloal actsical W umbing EB Gas PiP City ING DIVISION Bull. REVIEWED FOR CODE COMPLIANCE NFPA MAR 1 () 23O City OfTuiwta Q ILDING DP/ ION NOTES: 1. CONTRACTOR SHALL REVIEW THE SPECIFICATIONS, GENERAL NOTES, KEY NOTES, ELECTRICAL PLANS AND THE LANDLORD DESIGN CRITERIA BEFORE BIDDING AND STARTING ANY CONSTRUCTION WORK. 2. ALL INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF THE DESIGN DOCUMENTS, LANDLORD DESIGN CRITERIA AND N.E.C. REQUIREMENTS. 3. CONTRACTOR SHALL COORDINATE WITH THE LANDLORD'S CRITERIA AND SHALL FURNISH AND INSTALL NEW POWER SUPPLY AND ALL POWER SUPPLY EQUIPMENT IN COMPUANCE WITH THE RISER DIAGRAM, KEY NOTE #22 AND PANEL SCHEDULES. 4. CONTRACTOR FURNISH AND INSTALL ALL NEW WIRING AS SHOWN ON THE ELEC. PLANS AND RISER DIAGRAM. ALL NEW WIRING SHALL BE IN COMPLIANCE WITH N.E.C. TABLE 310 -16, AND PANEL SCHEDULES. 5. PULL STRINGS SHALL BE PROVIDED IN ALL EMPTY CONDUIT. FOR TELEPHONE AND LOW VOLTAGE SYSTEM. 6. INTERIOR TELEPHONE WIRING SHALL INCLUDE FURNISHING AND INSTALLING ALL TELEPHONE JACKS, AND COVER PLATES AS REQUIRED. COORDINATE WITH THE TENANT. 7. LABEL ALL ELECT. EQUIPMENT WITH ENGRAVED BAKELITE NAMEPLATE OR EMBOSSED PLASTIC NAME STRIP. LABEL ALL PANELS AS SHOWN ON THE RISER DIAGRAM. 8. FURNISH A TYPE WRITTEN CIRCUIT DIRECTORY CARD FOR ALL PANELS, LISTING ALL USED AND SPARE CIRCUITS. 9. CONTRACTOR SHALL VERIFY AND COORDINATE ALL ELECTRICAL REQUIREMENTS AND LOCATIONS OF ALL HVAC EQUIPMENT PRIOR TO INSTALLATION. 10. ALL OUTLET AND SWITCH COVER PLATES SHALL BE STAINLESS STEEL. ALL OUTLET BOXES SHALL BE MOUNTED FLUSH IN WALLS AND SHALL BE MOUNTED AT HEIGHT AS INDICATED ON THE EQUIP. PLAN. COORDINATE ALL LOCATIONS WITH EQUIPMENT INSTALLATION AND ARCHITECTURAL DRAWINGS. 11. ALL ELECTRICAL DEVICES AND EQUIPMENT SHALL BE EFFECTIVELY GROUNDED IN ACCORDANCE WITH N.E.C. REQUIREMENTS. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS UNLESS NOTED OTHERWISE. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR COMMUNICATION WITH THE PROPERTY OWNER'S PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 14. CONTRACTOR TO SEAL ALL WALL PENETRATIONS IN AN APPROVED MANNER TO INSURE THE FIRE RATING INTEGRITY OF THE INVOLVED AREAS. 15. COORDINATE FINAL INSTALLATION REQUIREMENTS WITH PROPER AUTHORITIES. AND LANDLORD'S MANAGER. 16. CONTRACTOR, UPON COMPLETION OF HIS WORK , SHALL BE RESPONSIBLE TO PROVIDE ANY AND ALL CERTIFICATIONS. 17. CONTRACTOR SHALL COMPLY WITH THE LANDLORD'S DESIGN CRITERIA FOR ELECTRICAL AND FIRE ALARM SYSTEMS. MAKE NECESSARY CONNECTIONS BETWEEN TENANT'S FIRE DETECTING DEVICES AND THE LAND LORD'S FIRE ALARM STATION. 18. ALL CONDUIT RUNS ABOVE CEILING SHALL BE PARALLEL OR PERPENDICULAR TO THE COLUMN LINES. 19. ALL CABLES AND WIRES SIZES SHALL COMPLY WITH N.E.C. TABLE 310 -16, 2005. MINIMUM SIZE OF CONDUCTOR SHALL BE #12 AWG CU. NO. 10 WIRES SHALL BE USED IN PLACE OF #12 FOR CIRCUITS LONGER THAN 100 FEET FROM PANEL TO LOAD. ALUMINUM CONDUCTOR SHALL NOT BE PERMITTED. WIRE INSULATION SHALL BE THHN OR THWN. 20. ALL INTERIOR WIRING SHALL BE CONCEALED AND IN GAL. STEEL OR EMT COND. AND IN COMPUANCE WITH THE N.E.C. AND LAND LORD'S DESIGN CRITERIA. 21. CONTRACTOR MAY USE FL XIBLE CONDUIT FROM JUNCTION BOX TO THE LIGHTING FIXTURE, BE-TEN LIGHTING FIXTURES, AND TO OTHER DEVICES PROVIDED THE LENGTH OF THE FLEX. CONDUIT IS NOT MORE THAN 6 FEET. 22. MC CABLES SHALL NOT BE USED FOR HOME RUN CIRCUITS AND FOR THE WIRING WITHIN PARTITION OR DEMISING WALL CONSTRUCTION. ALL IN -WALL CONCEALED WIRING MUST BE RUN IN RIGID CONDUITS. 23. THE GROUND ON THE SEPARATELY DERIVED SERVICE SHALL BE BONDED TO THE BUILDING STEEL AND TO THE INCOMING COLD WATER METAL PIPING WITH CAD WELD CONNECTION. REFER TO KEY NOTE #22. 24. ALL BREAKERS IN ALL PANELS SHALL BE BOLTED THERMAL MAGNETIC TYPE. TWO (2) AND THREE (3) POLE MOLDED CASE CIRCUIT BREAKERS SHALL BE WITH COMMON TRIP. 25. UNLESS NOTED OTHERWISE, WIRE AND CABLE SIZES SHALL BE IN COMPLIANCE WITH KEY NOTE # 22, RISER DIAGRAM AND THE N.E.C. TABLE 310 -16. 26. ROMAX, TYPE AC AND NM CABLES SHALL NOT BE PERMITTED. 27. CONDUCTORS SHALL BE COPPER PER LL CRITERIA. 28. ALL BREAKERS USED FOR LIGHTING CIRCUITS SHALL BE CONTINUOUS DUTY, UGHT SWITCHING RATING. DLO 'S SPCC NOTES: TENANTS LIGHTING AND LIGHTING CONTROLS SYSTEM SHALL COMPLY WRITHE WASHINGTON STATE NON - RESIDENTIAL ENERGY CODE STOREFRONT SIGNAGE AND LIGHTING TIME CLOCKS SHALL BE SET TO MAIL'S OPERATING HOURS. ALL LIGHTING IN FORWARD SELLING AREA MUST BE INCANDESCENT WITH LOW IRON TEMPERED GLASS SAFETY LENS, PER FOOD PREPARATION AND LOCAL CODES, ON SEPARATE CIRCUIT WITH A 7 DAY TIME CLOCK SET TO MALL'S OPERATING HOURS. FOOT -CANDLE LEVEL, AT COUNTER HEIGHT, MUST BE AN AVERAGE OF 50 MAINTAINED. ALL TRACK LIGHTS MUST BE IN RECESSED TROFFERS, LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANTS USE NO CONDUIT WILL BE PROVIDED, LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANTS SPACE. TENANTS TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. TRANSFORMERS ARE TO BE FLOOR MOUNTED_ COORDINATE WITH WESTFIELDS ONSITE COORDINATOR. ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE, ON BACK WALL, FOR TEMPORARY ELECTRICAL FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE, LANDLORD PROVIDED MAIN DISCONNECT MEANS FOR TENANT IN A LANDLORD ELECTRICAL ROOM AS WELL AS CONDUIT AND CONDUCTORS (FEEDER) FROM THE MAIN DISCONNECT MEANS TO A LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE, IF NEEDED TO ACCOMMODATE TENANT CONSTRUCTION, THE TENANT SHALL RELOCATE THE LANDLORD PROVIDED DISCONNECT SWITCH AND ASSOCIATED FEEDER, TENANT SHALL FURNISH AND INSTALL CONDUIT AND CONDUCTORS FROM FUSED DISCONNECT SWITCH TO TENANTS' MAIN FUSED DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANELBOARD. LANDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORD'S ELECTRICAL ROOM. THE LANDLORD -OWNED NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION, TENANTS ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANTS MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE - EIGHTH INCH (118) THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. RS. THE MINIMUM SIZE SHALL BE ONE INCH (1 ') WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED, NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. HANGERS, CLAMPS AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. KEYNOTES: • PROVIDE LOCK TAB AT CIRCUIT # A -8 IN 'ON' POSITION. EXIT, NIGHT AND EMERGENCY LIGHTS SHALL BE WIRED AHEAD OF ANY LOCAL SWITCHES. O CONTRACTOR MUST COORDINATE AND VERIFY LIGHT FIXTURE MODEL NUMBERS WITH THE TENANT BEFORE PURCHASING ANY NEW UGHT FIXTURES. LIGHT SCHEDULE IS FOR REFERENCE ONLY. V COORDINATE EXACT LOCATION OF LCD MONITORS AND INSTALL POWER OUTLETS FOR THEM AS REQUIRED. MAKE ALL CONNECTIONS AS REQUIRED. �4 INSTALL JUNCTION BOX AND SINGLE POLE 120V. TOGGLE SWITCH IN SOFFIT FOR CONNECTION OF SIGNAGE XFRMR. COORDINATE EXACT LOCATION WITH ARCHITECTURAL PLANS AND DETAILS. ROUTE MENU AND STORE SIGN CIRCUITS THROUGH A TIME CLOCK TIC. �-� COORDINATE TIME SETTINGS WITH THE LANDLORD. ALL LIGHTS SHALL BE CONTROLLED BY THE BREAKERS INSIDE THE PANEL. ALL BREAKERS WHICH SUPPLY POWER TO THE LIGHTING CIRCUITS SHALL BE LIGHT DUTY RATED. THIS IS TYPICAL. �7 PROVIDE A MINIMUM 1/2" CONDUIT W /WIRE FROM TELEPHONE OUTLET BACK TO TELEPHONE BOARD LOCATED IN WORK AREA. THIS IS TYPICAL FOR ALL TELEPHONE OUTLETS. O8 CONTRACTOR SHALL FURNISH AND INSTALL TELEPHONE CONDUIT TO TENANT'S TEL BD "TTB ". FURNISH AND INSTALL TEL. CABLE FROM TO LANDLORD'S DISTRIBUTION POINT TO THE TENANT'S TEL. BOARD "TTB ". COORDINATE ALL TELEPHONE REQUIREMENTS WITH TENANT. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND DATA /TEL. OUTLETS. THE TELEPHONE SYSTEM SHALL BE COMPLETE AND FUNCTIONAL. • ALL OUTLETS WITHIN 6' OF ANY SINK SHALL BE GFI OUTLETS. ALL KITCHEN AREA OUTLETS SHALL BE WITH GFI TO COMPLY WITH N.E.C. STD. #210.8(B)(2). TO ECONOMIZE THE COST THE CONTRACTOR SHALL INSTALL FIRST OUTLET AT WHICH THE HOME RUN IS CONNECTED, WITH GFI AND ALL OTHER DOWN STREAM OUTLET NORMAL WITHOUT GFI. 1 Q THE CONTRACTOR SHALL FURNISH AND INSTALL FA SYSTEM INCLUDING ALL DEVICES IN COMPUANCE WITH THE POWER PLAN AND ANSUL WIRING DIAGRAM, LANDLORD'S CRITERIA, NFPA AND LATEST APPLICABLE CODE REQUIREMENTS. COORDINATE WITH THE LANDLORD AND DETERMINE FA DEVICES MODEL NUMBER. TENANTS FA SYSTEM TIE CONNECTIONS TO THE BASE BUILDING FA SYSTEM SHALL BE PROVIDED BY THE LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. 11 VERIFY WITH LANDLORD AND FURNISH AND INSTALL DUCT SMOKE DETECTOR, RELAY AND REMOTE INDICATOR. TIE RELAY INTO DUCT MT'D SMOKE DETECTOR WHICH WHEN ACTIVATED WILL SHUT DOWN RTU -1, HOOD SUPPLY FAN. TIE TENANT'S FA SYSTEM TO LANDLORD'S FIRE ALARM CONT. PANEL PROVIDE CONDUIT, WIRES AND MAKE ALL CONNECTIONS AS REQUIRED. 12 DETERMINE EXACT LOCATION OF DUCT REMOTE INDICATOR AT SITE AND MAKE ALL CONNECTIONS AS REQUIRED. 13 THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL CABLES AND CONNECTIONS OF ALL COMPONENTS THAT ARE PART OF THE REFRIGERATION EQUIPMENT. 14 COORDINATE WITH TENANT AND INSTALL NEW BELL /BUZZER AS REQ'D., INSTALL BELL BUTTON AS SHOWN ON THE DRAWING. INSTALL BUZZER XFRMR, IN CEILING AND WIRIN +. FURNISH AND INSTALL A 20A OUTLETS FOR THE HEAT LAMP STRIP AND A 40 AMP, 208V, 3P, TWIST LOCK OUTLET FOR THE ELECTRIC GRIDDLE AS REQUIRED. DETERMINE EXACT LOCATION OF OUTLETS AT SITE WITH KITCHEN CONTRACTOR. MAKE ALL CONNECTIONS AS REQUIRED. 16 CONTRACTOR SHALL COORDINATE WITH KITCHEN EQUIP. CONTRACTOR AND ROUTE 208V, 10, CIRCUIT WITH NEUTRAL AND GRND CONDUCTORS FOR ICE MACHINE. FURNISH JB OR SPECIAL OUTLET AS REQ'D AND MAKE NECESSARY CONNECTIONS OF REMOTE CONDENSER. .0 CONTRACTOR SHALL COORDINATE WITH KITCHEN AND REFRIGERATION CONTRACTORS AND DETERMINE EXACT RATING OF ALL EQUIPMENT AND TYPE OF REQUIRED POWER LEAD CONNECTIONS AT EACH EQUIP. MUST ADJUST SIZE OF BREAKERS IF OR AS REQUIRED. THIS IS TYPICAL. 1$ DETERMINE EXACT LOCATION OF HOOD AND ANSUL PANELS AT SITE WITH HOOD PACKAGE. CONTRACTOR SHALL ROUTE POWER CIRCUIT FOR EXH. & SUPPLY FANS FROM POWER PANEL TO THE HOOD PANEL AND FROM HOOD PANEL TO THE EXHAUST AND SUPPLY FANS. COORDINATE WITH HOOD MFG. DRAWINGS FOR ADDITIONAL INFORMATION. THE CONTRACTOR SHALL FURNISH AND INSTALL 20A, 480V, 3 POLE, FUSED NEMA 3R, DISC. SWITCHES FOR EXHAUST AND SUPPLY FANS. MAKE ALL CONNECTIONS AS REQUIRED. 0 THE CONTRACTOR SHALL FURNISH AND INSTALL A NEW 20A FUSED, 480V, 3P, NEMA 3R DISC. SWITCH FOR CU -1 AND NEMA 1 DISC SW FOR AHU -1. AHU -1 SHALL BE A SINGLE POINT CONNECTION. ROUTE #10, CU, CONDUCTORS AS SHOWN. FURNISH AND INSTALL A WEATHER PROOF, GFI, OUTLET NEAR CU -1 UNIT AS SHOWN ON THE POWER PLAN. 20 ALL CONDUIT PENETRATIONS THROUGH CASEWORK SHALL BE CLEAN, TIGHT AND SEALED WITH WHITE SILICONE. THIS IS TYPICAL. 21 PROVIDE KEY -LOCK TABS AT CIRCUITS ROUTE CIRCUITS A -7 AND A -9 WITH ISOLATED GROUND CONDUCTORS. I 22 THE CONTRACTOR SHALL COORDINATE WITH THE LANDLORD AND SHALL FURNISH AND INSTALL A NEW 200 AMP, 277/480V, 30, 4W, POWER SUPPLY AS SCHEDULED BY THE LANDLORD IN COMPUANCE WITH LL'S CRITERIA, RISER DIAG., PANEL SCHEDULES AND AS DETAILED BELOW: a) COORDINATE WITH THE LANDLORD AND FURNISH AND INSTALL ALL POWER SUPPLY EQUIPMENT AS REQUIRED. REFER TO LANDLORD'S SPECIFIC NOTES. b) THE CONTRACTOR SHALL VERIFY WITH THE LANDLORD THAT THE MAIN SUPPLY FEEDER IS INSTALLED BY THE LANDLORD. REFER TO LANDLORD'S SPECIFIC NOTES. EXTEND EXISTING CONDUIT AND FEEDER TO THE PANEL "H" AS SHOWN ON THE RISER DIAGRAM. c) FURNISH AND INSTALL NEW PANELS "H" AND "A" IN COMPUANCE WITH RISER DIAGRAM AND PANEL SCHEDULES. PANEL "H" SHALL BE 277/480V, 30, 4W, WITH 200 AMP MCB. PANEL "A" SHALL BE 120/208V, 30, 4W, WITH 150 AMP MCB. BOTH PANELS SHALL BE WITH FULL SIZE GROUND, NEUTRAL BUSSES AND WITH BOLTED TYPE BREAKERS. d) FURNISH AND INSTALL A NEW DRY TYPE, 45 KVA XFRMR ABOVE PANELS. XFRMR SHALL BE WITH 6 STANDARD VOLTAGE REGULATION TAPS (2 TAPS +2.5% AND 4 TAPS - 2.5 %). INSTALL XFRMR ABOVE PANELS ON SUPPORTS IN COMPLIANCE WITH MANUFACTURER AND LL'S RECOMMENDATIONS. THE CONTRACTOR SHALL BOND THE TRANSFORMER NEUTRAL TO THE BUILDING STEEL AND AND TO THE COLD WATER METAL PIPE WITH EXOTHERMIC WELD CONNECTIONS AS SHOWN ON THE RISER DIAGRAM. e) THE CONTRACTOR SHALL INSTALL GROUNDING IN COMPUANCE WITH N.E.C. STD. #250, 2005. ALL UGHT FIXTURE AND OTHER EQUIPMENT SHALL BE GROUNDED. f) UNLESS NOTED OTHERWISE THE CONTRACTOR SHALL FOLLOWING SIZE OF WIRES PER N.E.C. TABLE 310 -16. (1) USE # 12 AWG, COPPER, THWN OR THHN, FOR 20A BRKRS. (2) USE # 10 AWG, COPPER, THWN OR THHN, FOR 25A AND 30A BREAKERS. (3) USE MINIMUM SIZE OF # 10 AWG, CU, THWN OR THHN WIRES FOR EXH /SUPPLY FANS AND HVAC EQUIPMENT CIRCUITS. (4) USE # 8 AWG, COPPER, THWN OR THHN, FOR 35A AND 50A BREAKERS. (5) USE # 6 AWG, COPPER, THWN OR THHN, FOR 60A BREAKERS. BREAKERS. APPROVE,.' P' r.._, ,�- 1r1pIC eL7nt t,".". 7'7 MuD,r''Li) CR FALTERED WITHOUT AU1 HORI7ATid FROM THE BUILDING OrF! I, .L, AU WORK SHA '..L BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS 7J'3.'::CT TO F;EI D INSPECTIONS SYMBOLS 2'X4' FLUORESCENT i O 2'X4' FLUORESCENT NIGHT LT (N /L) 2'X2' FLUORESCENT 0 1 2'X2' FLUORESCENT NIGHT UGHT 1'X4' FLUORESCENT 0 (0) CEILING MOUNTED LT FIXTURE. GOOSENECK WALL MOUNTED LIGHT FIXTURE HEX EXIT UGHT 114m EMERGENCY UGHT 7_7/0D, TRACK LIGHT dib DUPLEX RECEPTACLE WITH 120 V, 20 AMPERE RATING. HEIGHT 16" TO BOTTOM UNLESS NOTED OTHERWISE. (TYP.) u 40" ® DUPLEX RECEPT. OUTLET ABOVE COUNTER SHALL BE 40" AFF TO BOTTOM UNLESS NOTED OTHERWISE GFI DUPLEX W /GRND F. INTERRUPTER AT COUNTER SHALL BE 42" AFF TO BOTTOM UNLESS NOTED OTHERWISE dibIG DUPLEX W /ISOL. GRND CONDUCTOR AT A HEIGHT TO THE BOTTOM AS NOTED. 4". ;;; QUADRUPLEX WITH 120V, 20 A. HEIGHT AS NOTED @ SPECIAL "TWIST LOCK RECEPT" WTR PROOF, 480V, 30, OR 240V, 30, OR 240V, 10, FOR KITCHEN EQUIP. WITH AMPERE RATING AS SHOWN AT PANEL SCHEDULE AND AT DRAWING. 0 F FLOOR RECEPTACLE 0 C CEILING RECEPTACLE JUNCTION BOX REST ROOM EXHAUST FAN. 0� DISCONNECT SWITCH SP - SOUND SYSTEM SPEAKER 2 TELEPHONE JACK yCOMPUTER /DATA JACK FLUSH MOUNTED POWER PANEL 0 SURFACE MOUNTED POWER PANEL t3(4) THREE OR FOUR WAY SWITCH t DIMMER SWITCH TWO WAY SWITCH ' 9 WATER HEATER FACP FIRE ALARM CONTROL PANEL -LSS 4/12 F MANUAL PULL STATION - 270 -SPO 42" A.F.F. . F HORN /STROBE- 792 -7A -006 80" A.F.F. M MAGNETIC DOOR HOLDER- 1504 -AQ R FAN SHUT DOWN RELAY W/ ENCLOSURE- MR- 199X -13/C L DUCT SMOKE DETECTOR 6264B -001/ 6260A- 100/6261- 003- 6251B -001A R; Ir1L REMOTE INDICATOR /TEST STATION --- 6262A -001 STROBE -- 202 -7A -001 80" AFF F 0 HEAT DETECTOR -2816 SMOKE DETECTOR - 62506/6251B -001A 0 ) REFER TO THE CODED NOTE NUMBER. Lu� CONCEALED IN WALL, CEILING OR UNDER GROUND CONDUIT RUN CONSISTING OF: Z - GROUND CONDUCTOR III - SMALL LINES INDICATE POWER NON GROUNDED CONDUCTORS. I - BIG LINE INDICATES NEUTRAL CONDUCTOR III Public works, Building Division PERMIT NUMBER � w FEB 15 2008 PERMIT CENTEh EL0B-iSI FILE COPY DATE: 12 -24 -07 JOB NO: 0734 DRAWN: CHECKED: SOUTHCENTER SPACE FC 1 1 633 SOUTHCENTER WA 98188 REVISIONS AREVISED PER LANDLORD /OWNER 1/23/08 DAVID HIATT ARCHITECT 4410 W. Melrose Avenue Tampa, Florida 33629 p. 813.289.3336 f. 813.289.3332 REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON ME `s POWER & UGHTING PAN SHEET NUMBER togl MCB: 200 AMP MLO: N/A A.I.C.: 22,000 AMP VOLTS: 277/480 V PHASE: 3, S/N WIRE: 4 WITH GROUND BUSS ELECTRICAL Imo- TENANT ROOM SPACE BLDG: SOUTH CENTER, SEATTLE, WA, SP # FC -11 MTD: SURFACE DESCRIPTION OF LOAD BRKR KVA PH LOAD CIR PHASE CIR KVA PH LOAD BRKR DESCRIPTION OF LOAD AMP P WA 03 0C NO A B C NO � �B �C P AMP M COND UNIT CU -1 20 3 2.10 1 • 2 1.74 3 70 45 KVA XFRMR T 2.10 3 • 4 11.68 v v v 2.10 5 • 6 11.87 v v W AHU -1 W/8 KW HTR 30 3 3.52 7 • 8 ''-- ..-- -" SPACE 3.52 9 • 10 .�. �. \, ,_, 3.52 11 • 12 M WATER HEATER 20 3 4.00 13 • 14 4.00 15 • 16 v v 4.00 17 ■ 18 SPACE 19 • 20 21 • 22 23 • 24 25 • 25 27 • 28 TOTAL 19.62 19.62 9.62 TOTAL CONNECTED KVA OA OB OC L LIGHTING: R RECEPTACLE W WATER HEATER: 4.00 4.00 4.00 H HEATING: 3.52 3.52 3.52 M MOTOR /HVAC /FAN .10x2.10 2.10 T TRANSFORMER /PANEL /ATS: 11.7411.6811.87 K KITCHEN EQUIPMENT E EQUIPMENT 1 MISCELLANEOUS x11.7411.6$11.87 TOTAL 7 DAY, 24 HRS PROGRAMMABLE TIME CLOCK T/C LL'S DISC SW WITH 200A FUSES AT LL'S DIST. MTR CENTER FOR 480V, 30, SERVICE FOR SPACE# FC -1 EXIST DISC SW NEW 4 # 3/0, CU, 1 - #6, CU, GRND, THHN OR THWN IN exist 2 "C. I--. i-- 200AF 200 AMP MCB 45 KVA DRY TYPE XFRMR. 480 V. "DELTA" PRIMARY 120/ 208 V. "WYE" SECONDARY EXIST ELEC. MTR 150 AMP MCB OA 0B oC 21.36 21.30 21.49 TOTAL CONNECTED KVA 78 77 78 TOTAL CONNECTED AMPS EXIST LANDLORD'S WIRE WAY VERIFY LOCATION AT SITE COLD WTR METAL PIPE (1) REFER TO PANEL "A" SCHEDULE FOR THESE LOADS DETAIL. 4 - #1 /0, CU, 1-- #6, CU, GRND IN 2" C. 00 EXIST 1 # 4, CU, TO GRND, BLDG. STEEL AND COLD WTR METAL PIPE PER N.E.C. #250. MCB: 150 AMP MLO: N/A A.I.C.: 10,000 AMPS PHASE: 3, S/N WIRE: 4 BLDG: SOUTH CENTER, SEATTLE, WA, SP # FC-11 VOLTS: 120/208 V WITH ISO & EQUIP. GROUND BUSES MTD: SURFACE ELECTRICAL POWER RISER DIAGRAM RISER DIAL. NOTES: V COORDINATE WITH LANDLORD (LL) AND FURNISH AND INSTALL A NEW POWER SUPPLY AND EQUIPMENT IN COMPLIANCE WITH RISER DIAGRAM, PANEL SCHEDULES AND KEY NOTE #22 ON SHEET E1. INSTALL GROUNDING SYSTEM AS REQUIRED TO COMPLY WITH RISER DIAGRAM AND WITH N.E.C. STD. #250, REQUIREMENTS. FURNISH AND INSTALL NEW PANELS "H AND A" IN COMPLIANCE WITH THE KEY NOTE #22, RISER DIAGRAM AND PANEL SCHEDULE. PANELS SHALL BE WITH BOLTED TYPE BREAKERS. FURNISH AND INSTALL A 45 KVA XFRMR AS SHOWN AND AS DESCRIBED IN KEY NOTE #22 ON SHEET El AND IN SPECIFICATIONS. MAKE SURE THAT THE NEUTRAL OF THE TRANSFORMER I5 BONDED WITH THE BUILDING STEEL AND TO THE INCOMING COLD WATER METAL PIPE WITH EXOTHERMIC WELD CONNECTIONS AS SHOWN ON THE RISER DIAGRAM. DESCRIPTION OF LOAD BRK KVA PH LOAD CIR PHASE CIR KVA PH LOAD BRKR DESCRIPTION OF LOAD AMP P OA OB OC NO A B C NO 0A OB OC !AMP K 2 DOOR FREEZER (#47A) 20 1 1.79 1 ■ 2 0.29 20 L S KITCHEN L WORK TOP FREEZER ( #39B) 0.60 3 ■ 4 0.25 � RECESS / PENDANT E,F) DRINK DISPENSER (( #12) 1.02 5 • 6 1.20 SIGN /UC COVE (C) (T /C) R POINT OF SALE SYSTEM ( #2)(IG) 0.80 7 • 8 0.19 EMERGENCY/NT/EXIT '1, POINT OF SALE SYSTEM ( #2)(IG) 0.40 9 • 10 1.35 RACE S G S�NDWICH TOP REFI G. 39) T 0.56 11 • 12 + 0.36 Mr 'LCD MONITORS e K ODA DISPENSER_ 7 0.60 13 • 14 0.80 `�r�� BAG & is' S K R KITCHEN 'ACT' CLE 0.50_ _ 15 • 16 0.50 _IIU SALES AREA RECEPT R 1 Q0 �k� P N S 26 _ _ 1 OD 17 • 18 1.10 fl HEAT LAMP STRIP ( #17) E K 2 DOOR COOLER ( #47B) 1.25 19 • 20 0.50 TIME CLOCK /TRIP REL /BUZZER 1 2 DOOR COOLER ( #47B) v 1.25 21 • 22 0.56 20 SANDWICH TOP REFRIG (#39) K HV GAS FRYER ( #24) 20 1 0.36 23 • 24 RESERVED FOR SHUNT TRIP RESERVED FOR SHUNT TRIP 25 ■ 26 3.24 3 35 L G R CXL` G iID' LE ( #18) ICE MACHINE ( #29) 20 2 0.75 27 • 28 3.24 .L .�. 0.75 29 • 30 3.24 i i M EXH /SUPPLY FANS ( #26) 40 3 2.28 31 • 32 RESERVED FPR SHUNT TRIP v 2.28 2.28 35 • • 36 SPACE i SPACE 37 • 38 39 • 40 `. 41 • 42 v TOTAL 6.72 5.78 5.97 TOTAL CONNECTED KVA OA 0B OC L LIGHTING: 0.48 1.60 1.56 R RECEPTACLE 0.80 1.40 W WATER HEATER: H HEATING: M MOTRO /HVAC /FAN: 2.28 2.28 2.28 T TRANSFORMER /PANEL /ATS: K KITCHEN EQUIPMENT 7.68 6.40 5.93 E EQUIPMENT /FOOD HEAT LAMP 1.10 1 MISCELLANEOUS 0.50 1.00 5.021 5.90 1 5.90 ITOTAL OA OB OC 11.74 11.68 11.87 OTAL CONNECTED KVA 98 98 99 OTAL CONNECTED AMPS (1) PROVIDE LOCK TAB AT THESE BREAKERS IN "ON" POSITION. (2) INSTALL THIS BREAKER WITH SHUNT TRIP DEVICE. (3) ROUTE THIS CIRCUIT THROUGH A TIME CLOCK (4) ROUTE THIS CIRCUIT WITH ISO. GROUND CONDUCTOR. LIGHTING noun SCHEDULE 0000 st 8 431He TTA - i i DESCRIPTION OF LOAD BRKR KVA PH LOAD CIR PHASE CIR KVA PH LOAD BRKR DESCRIPTION OF LOAD AMP P WA 03 0C NO A B C NO � �B �C P AMP M COND UNIT CU -1 20 3 2.10 1 • 2 1.74 3 70 45 KVA XFRMR T 2.10 3 • 4 11.68 v v v 2.10 5 • 6 11.87 v v W AHU -1 W/8 KW HTR 30 3 3.52 7 • 8 ''-- ..-- -" SPACE 3.52 9 • 10 .�. �. \, ,_, 3.52 11 • 12 M WATER HEATER 20 3 4.00 13 • 14 4.00 15 • 16 v v 4.00 17 ■ 18 SPACE 19 • 20 21 • 22 23 • 24 25 • 25 27 • 28 TOTAL 19.62 19.62 9.62 TOTAL CONNECTED KVA OA OB OC L LIGHTING: R RECEPTACLE W WATER HEATER: 4.00 4.00 4.00 H HEATING: 3.52 3.52 3.52 M MOTOR /HVAC /FAN .10x2.10 2.10 T TRANSFORMER /PANEL /ATS: 11.7411.6811.87 K KITCHEN EQUIPMENT E EQUIPMENT 1 MISCELLANEOUS x11.7411.6$11.87 TOTAL 7 DAY, 24 HRS PROGRAMMABLE TIME CLOCK T/C LL'S DISC SW WITH 200A FUSES AT LL'S DIST. MTR CENTER FOR 480V, 30, SERVICE FOR SPACE# FC -1 EXIST DISC SW NEW 4 # 3/0, CU, 1 - #6, CU, GRND, THHN OR THWN IN exist 2 "C. I--. i-- 200AF 200 AMP MCB 45 KVA DRY TYPE XFRMR. 480 V. "DELTA" PRIMARY 120/ 208 V. "WYE" SECONDARY EXIST ELEC. MTR 150 AMP MCB OA 0B oC 21.36 21.30 21.49 TOTAL CONNECTED KVA 78 77 78 TOTAL CONNECTED AMPS EXIST LANDLORD'S WIRE WAY VERIFY LOCATION AT SITE COLD WTR METAL PIPE (1) REFER TO PANEL "A" SCHEDULE FOR THESE LOADS DETAIL. 4 - #1 /0, CU, 1-- #6, CU, GRND IN 2" C. 00 EXIST 1 # 4, CU, TO GRND, BLDG. STEEL AND COLD WTR METAL PIPE PER N.E.C. #250. MCB: 150 AMP MLO: N/A A.I.C.: 10,000 AMPS PHASE: 3, S/N WIRE: 4 BLDG: SOUTH CENTER, SEATTLE, WA, SP # FC-11 VOLTS: 120/208 V WITH ISO & EQUIP. GROUND BUSES MTD: SURFACE ELECTRICAL POWER RISER DIAGRAM RISER DIAL. NOTES: V COORDINATE WITH LANDLORD (LL) AND FURNISH AND INSTALL A NEW POWER SUPPLY AND EQUIPMENT IN COMPLIANCE WITH RISER DIAGRAM, PANEL SCHEDULES AND KEY NOTE #22 ON SHEET E1. INSTALL GROUNDING SYSTEM AS REQUIRED TO COMPLY WITH RISER DIAGRAM AND WITH N.E.C. STD. #250, REQUIREMENTS. FURNISH AND INSTALL NEW PANELS "H AND A" IN COMPLIANCE WITH THE KEY NOTE #22, RISER DIAGRAM AND PANEL SCHEDULE. PANELS SHALL BE WITH BOLTED TYPE BREAKERS. FURNISH AND INSTALL A 45 KVA XFRMR AS SHOWN AND AS DESCRIBED IN KEY NOTE #22 ON SHEET El AND IN SPECIFICATIONS. MAKE SURE THAT THE NEUTRAL OF THE TRANSFORMER I5 BONDED WITH THE BUILDING STEEL AND TO THE INCOMING COLD WATER METAL PIPE WITH EXOTHERMIC WELD CONNECTIONS AS SHOWN ON THE RISER DIAGRAM. DESCRIPTION OF LOAD BRK KVA PH LOAD CIR PHASE CIR KVA PH LOAD BRKR DESCRIPTION OF LOAD AMP P OA OB OC NO A B C NO 0A OB OC !AMP K 2 DOOR FREEZER (#47A) 20 1 1.79 1 ■ 2 0.29 20 L S KITCHEN L WORK TOP FREEZER ( #39B) 0.60 3 ■ 4 0.25 � RECESS / PENDANT E,F) DRINK DISPENSER (( #12) 1.02 5 • 6 1.20 SIGN /UC COVE (C) (T /C) R POINT OF SALE SYSTEM ( #2)(IG) 0.80 7 • 8 0.19 EMERGENCY/NT/EXIT '1, POINT OF SALE SYSTEM ( #2)(IG) 0.40 9 • 10 1.35 RACE S G S�NDWICH TOP REFI G. 39) T 0.56 11 • 12 + 0.36 Mr 'LCD MONITORS e K ODA DISPENSER_ 7 0.60 13 • 14 0.80 `�r�� BAG & is' S K R KITCHEN 'ACT' CLE 0.50_ _ 15 • 16 0.50 _IIU SALES AREA RECEPT R 1 Q0 �k� P N S 26 _ _ 1 OD 17 • 18 1.10 fl HEAT LAMP STRIP ( #17) E K 2 DOOR COOLER ( #47B) 1.25 19 • 20 0.50 TIME CLOCK /TRIP REL /BUZZER 1 2 DOOR COOLER ( #47B) v 1.25 21 • 22 0.56 20 SANDWICH TOP REFRIG (#39) K HV GAS FRYER ( #24) 20 1 0.36 23 • 24 RESERVED FOR SHUNT TRIP RESERVED FOR SHUNT TRIP 25 ■ 26 3.24 3 35 L G R CXL` G iID' LE ( #18) ICE MACHINE ( #29) 20 2 0.75 27 • 28 3.24 .L .�. 0.75 29 • 30 3.24 i i M EXH /SUPPLY FANS ( #26) 40 3 2.28 31 • 32 RESERVED FPR SHUNT TRIP v 2.28 2.28 35 • • 36 SPACE i SPACE 37 • 38 39 • 40 `. 41 • 42 v TOTAL 6.72 5.78 5.97 TOTAL CONNECTED KVA OA 0B OC L LIGHTING: 0.48 1.60 1.56 R RECEPTACLE 0.80 1.40 W WATER HEATER: H HEATING: M MOTRO /HVAC /FAN: 2.28 2.28 2.28 T TRANSFORMER /PANEL /ATS: K KITCHEN EQUIPMENT 7.68 6.40 5.93 E EQUIPMENT /FOOD HEAT LAMP 1.10 1 MISCELLANEOUS 0.50 1.00 5.021 5.90 1 5.90 ITOTAL OA OB OC 11.74 11.68 11.87 OTAL CONNECTED KVA 98 98 99 OTAL CONNECTED AMPS (1) PROVIDE LOCK TAB AT THESE BREAKERS IN "ON" POSITION. (2) INSTALL THIS BREAKER WITH SHUNT TRIP DEVICE. (3) ROUTE THIS CIRCUIT THROUGH A TIME CLOCK (4) ROUTE THIS CIRCUIT WITH ISO. GROUND CONDUCTOR. LIGHTING noun SCHEDULE 0000 8 431He TTA TYPE DESCRIPTION MANUFAC. CATALOG LAMP MTG. VOLT REMARKS LAMPS/ BALLASTS BALLAST/ TOTAL A 2 -LAMPS 2x4 W /ELECTRONIC RAPID 2 ELECTRONIC 1 64 O RECESS TROFFER MERCURY 35E2320CT9A125ELB (2) F032T8/841 RECESSED 120 START BALLAST SYLVANIA _ QTP2X32T8 /UNV PSX -SC 2 -LAMPS 2x4 W /ELECTRONIC RAPID 2 ELECTRONIC 1 1 64 B r7 RECESS TROFFER MERCURY 35E2320CT9A125ELB (2) FO32T8/841 RECESSED 120 START BALLAST SYLVANIA QTP2X32T8 /UNV PSX-SC COUNTER BARTCO BFLSLM -14/6 28W T5 UNDER MINIATURE UNEARE T: INTEGRAL C I 0 1 COVE UGHT LIGHTING 46 1/16" LAMP COUNTER 120 FLUORESCENT SINGLE 1 BALLAST. 1 28 TELL- 230 -3200 COVE UGHT WIDTH STAGGERED. 6" LAMP OVERLAP. E ' RECESSED HALO H274HP -•120V F13DTT -Halo Z64 RECESSED 120 1 1 13 DOWN UGHT DECORATIVE VAXCEL PD30119SN - (1)5DW B10 MPT COORD W /OWNER LAVA SWIRL MINI CAND C MONOPOINT 120 CALL UGHTING 1 N/A N/A 50 F CD UGHT PENDANT PENDANT UNIVERSE INCANDESCENT (800) 801 -2207 EX EXIT UGHT ATUTE PNLRU FURNISHED UNIVERSAL 120 90 MINUTE BAIT. N/A N/A N/A 20 W /UNIT BACKUP POWER RECESSED PAR 36 SEALED FULL LIGHT OUTPUT ' - EMERGENCY ENCORE ERG-630-R ERG SE � RECESSED 12 FOR OP TO 4 HOURS N/A N/A N/A EM LIGHT UGHTING AM LAMP BATTERY CAPACITY 30 OTES: 1 ELECTRICAL CONTRACTOR TO INQUIRE ABOUT LOCAL REBATES ON LIGHT ALL LAMPS TO BE SYLVANIA UNLESS NOTED OTHERWISE. FIXTURES. �--� Q2 INSTALLATION OF LIGHT FIXTURES SHALL BE ACCORDING TO PROVIDE UGHT TUBE COVERS, LENSES, ETC., AS REQUIRED TO PROTECT FOOD MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE SERVICE AREA. REQUIREMENTS. EQUIPM041 - UST MARX RESPONSIBILITY QNTY DIMS SPECIFICATIONS: REMARKS: ITEM/ POINT OF SALE COORD. W /OWNER 2 SYSTEM 3 (SSCI) 6 BOX • -IN 1 COKE CO. (SSCI) SODA DISPENSER/ "SITES" #WRD -6 ; REQ. 11OV/20 AMP FIELD VERIFY EQUIP. BEFORE MAKING ANY CUTS IN THE 7 ICE BIN 2 GRND. OUTLET ' 1/2" CW REDUCED COUNTER TOP. FITS CUT OUT MEASURING 23 -1/4 "x23 -1/4" (SSCI) TO 3/8" W /GAT VALVE. 1 -1/2" DRAIN CONTACT SANDY MANUEL(813)973 -3465 TO COORD. DELIV. 10 MENU BOARD 1 VARIES CUSTOM FABRICATED LCD MONITORS SEE COORDINATE WITH OWNER (SSCI) PLAN DRINK CRATHCO D35 12 DISPENSER 1 115V/fi0 HZ, 8.5 AMPS (SSCI) 17 ST• RIPE 1 48" W HATCO GRAN -48 SINGLE OVERHEAD GLO -RAY® INFRARED FOODWARMER, HIGH WATTAGE, 6" D WARMER HEAT LAMP TUBULAR METAL HEATER ROD, SINGLE HEATER ROD (SSCI) 2„ H HOUSING, ALUMINUM CONSTRUCTION, 1100 WATTS, 48" LONG ELECTRICAL 1 12` W TAYLOR COMPANY 208 VOLT/ 60 HZ / 30 PROVIDED W/ L15 -30P 18 GRILL 35' D QS12 9.fi KW, 27 AMP (SSCI) ) 15` 11 i..s � HIGH VOLUME 20.83 "W FRYMASTER #MJCF UNIT TO BE VENTED UNDER CANOPY W /MECH. EXHAUST 24 GAS FRYER 1 39.86" D. 150,000 BTU /HR SYS. 3/4" I.P.S. MANIFOLD AND GAS CONNECTION. 46" H. PROVIDE "DORMONT"' QUICK DICONNECT SYSTEM. GAS (SSCI) PRESSURE TO BE 6" W.C. FOR NATURAL OR 11" W.C. FOR PROPANE. 120/24V SUPPLY GOHZ 1 AMP 26 EXH. HOOD 1 24 "H W /LIGHT FIXTURES LENGTH & WIDTH VARY, SEE PLAN AND HOOD SHOP DWGS. (SSCI) SEE HOOD DRAWING EXHAUST /SU SMOKE FROM BE CUSTOM SIZED FOR ANSUL SYSTEM i "ANSUL" PRE -ENG. LIQUID CHEMICAL ASSEMBLY, TESTING AND CERTIFICATION BY GEN. CONTR. TANKS AND FIRE SUPPRESSION SYS. W /FIXED INSTALL SYSTEM AS CLOSE TO CEILING AS POSSIBLE. CONTROL NOZZELS. SYS. TO BE UL CLASSIFIED MIN HGT. TO BO-TT. OF UNIT TO BE 6' -6" AFF. PANEL AND INSTALLED PER NFPA #96 REQ. NOTE: NOZZELS AND PIPING IN PUBLIC VIEW SYSTEM SHALL BE CAPABLE OF SHALL BE CHROME FINISHED. AUTOMATIC AND MECH. OPERATION EL.EC: FOR EMERGENCY SHUT OFF, CONNECT CONTROL W /AUTO SOUNOID GAS VALVE PANEL TO SOLINOID FOR. SHUT DOWN OF GAS SUPPLY SHUT DOWN. UPON ACTIVATION. PLUMB:CONNECT ANSUL TANKS TO HOOD W/ RED PAINTED PIPE. INSTALL GAS SOLINOID VALVE SIZED PER PIPE SIZE. 29 ICE MAKER CUBER "HOSHIZAKI" #KM -630 MAE CUBER ALLOW 6" ATR0V/ ARAN 7EAMB SIMPLEX UNIT. 80" AFF ICE BIN 22" W. AIR COOLED: 1 30 -1/4" H. 208- 230/60/1 15.0 AMPS (3 WIRE WITH NEUTRAL FOR 115V) 3 WIRE W /NEUTRAL FOR 115V PROVIDE 6' CORD AND PLUG TO UNIT. BIN B -500PD W/ 6" LEGS: PROVIDE 3/4" INDIRECT WASTE DRAINS FROM BIN & 30" W. CUBER. 3/8" O.D. CONDENSATE AND 1/2" INDERECT 31 -1/2" D WASTE FROM CONDENSER TO FLOOR DRAIN. ( SSCI) 46" H. MAINFOLD AS REQUIRED. SANDWICH TOP 27" W TRUE 39 REFRIG. 2 34 "D TRUTSSU2712MBA 46 "H 115/60/1 4.6 AMPS 1/5 HP WORK TOP 1 48 3/8" W TRUE 39B FREEZER TWT -48F 33 "H 115/60/1 5 AMPS 1/5 HP 40 WATER HEATER SEE PLUMBING 1 (CSCI) 2 DOOR 1 5�" TRAULSEN #G22010 47A FREEZER 35" D. 115/60/1 NEMA L14 -20P PLUG (SSCI) 83" H. 14.9 AMP 3/4 HP 2 DOOR 2 58" L TRAULSEN #RHT232WUT -FHG 47B COOLER 35" D. 115/60/1 NEMA L14 -20P PLUG (SSCI) 83" H. 10.4 AMP 1/2 HP 51 ELECT. PANELS i SEE ELECTRICAL DWG. (CSCI) DATE: 12 -24 -07 JOB NO: 0734 DRAWN: CHECKED: U La- W U (X 44( W z� U f- Z L.L. U O D 0 WA 98188 LLJ J w REVISIONS REVISEP PER LANDLORD I/23/08 A -20(2) CONTACT FROM FIRE DETECTION SYSTEM. RELAY SQ. "D" CLASS 8501 TYPE XM040-V02 120 VAC COIL, NEMA 1 ENCLOSURE, CLASS - 9991-UE7. _ _ CONTACT LOCATED IN ANSUL SYSTEM CONTROL HEAD. TO AHU UNIT FAN CONTROL CIRCUIT (CONTRACTOR TO VERIFY) SHUNT TRIP BREAKER USED FOR UNDER HOOD COOKING EQUIPMENT _. THE TENANT'S FIRE ALARM /PROTECTION. CONTRACTOR TO VERIFY WITH THE LANDLORD'S ON -SITE REPRESENTATIVE, EARLY IN PROJECT, THE TYPE OF FIRE LIFE SAFETY SYSTEM TO BE USED AND THE COMPONENTS THAT WILL BE REQUIRED TO TIE INTO THE LANDLORD'S SYSTEM. MAKE CONNECTIONS IN COMPLIANCE WITH NFPA 72 AND LANDLORD'S CRITERIA. EF1 (3HP) LANDLORD'S JUNC. BOX. VERIFY LOCATION. CONNECTIONS TO THE BASE BUILDING SHALL BE PROVIDED BY THE LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. SHUNT TRIP BREAKERS (TYP) #10 AWG GAS SOLENOID VALVE HOOD CONTROL PANEL �:=.i A -17(1) (FOR HOOD CONT. AND LTS ANSUL SYSTEM CONTROL PANEL .-- --PULL STATIONS FURNISHED 3 WITH UNIT. VERIFY LOCATION. TO HOOD CONTROL PANEL FOR FAN SHUT DOWN SMOKE DET. VERIFY LOCATION. TO ANSUL PANEL NOTES: OI ALL WIRING SHALL BE #12 THWN IN 1/2" CONDUIT. O REFER TO SHEET E -2 FOR SHUNT RELAY TRIP DIAGRAM AT THIS SHEET O MAKE ALL CONNECTION OF DUCT DETECTORS AND OTHER FA DEVICES PER NFPA --72. ANSUL SYSTEM WIRING DIAGRAM NOTES: O1 ALL WIRING SHALL BE #12 THWN IN 3/4" CONDUIT UNLESS NOTED OTHERWISE. O2 THE CONTRACTOR SHALL FURNISH AND INSTALL 30A, 208V, 3P, NEMA 3R, DISC SWITCHES AND WIRING FOR FANS. THE COMPLETE SYSTEM SHALL BE WORKING AS REQUIRED. REFER KEY NOTE #18 ON SHEET El. HOOD WIRING DIAGRAM TOAD `CSS LOAD VOLT CONNECTED (KVA) FACTOR DEMAND (KVA) SIGNAGE 120 1.56 125% 1.95 UGHIING (INLAND) 120 1.60 a 125% 2.00 UGHTING (FLUOR) 120 0.48 125% 0.60 TRACK LIGHTS 120 - -- 125% : - --- HEAT LAMPS 120 1.10 125% 1.38 CONY. OUTLETS 120 2.20 100% 2.20 MISC. 120 1.50 100% 1.50 KITCHEN EQUIP. 120/208 20.01 a 65% 13.00 __21.01 (2) 480 12.00 7.80 �, _ WATER HEATER 480 (1) 65% (1) AIR COND. OR HT 480 10.56 100% 10.56 MOTORS 208 6.84 100% _ 6.84 LARGEST MOTORS 208 : 3.42 (3) 25% 0.86 XFRMR LOSSES 480 • 45.00 KVA 1.50% 0.68 TOTAL , ( 5785 (3) 1 5a.2 (1) WATER HTR 1S 12 KW, 480V, 30. THIS LOAD IS INCLUDED IN THE IT H. 0 c _O D (2) THE KITCHEN LOADS PER N.E.C. TABLE 22 -20, AFTER USING THE DIVERSITY FACTORS, COME OUT TO BE 20.80 KVA WHICH ARE LESS THAN THE SUM OF THE TWO LARGEST LOADS (9.72 + 12.0 = 21.72 KW). HENCE TO COMPLY WITH N.E.C. 220 -20 WE CONSIDERED 21.72 KW FOR KITCHEN APPLIANCES LOADS IN THE FOLLOWING CALCULATIONS. - (3) LARG • T MOTOR LOAD IS NOT INCLUDED IN THE CONNECTED LOAD TOTAL IT 15 NOTED FOR DEMAND LOAD CALCULATIONS ONLY. 120/2 8. 3� POWER SUPPLY CALCULATIONS: 1. TOTAL DEMAND LOADS = 30.33 KVA 2. DEMAND CURRENT/0 = : : u `5 c 120/208V,30 3. DESIGNED XFRMR = 45 KVA , 480/120- -208V, 3o, 4W. 4. DESIGNED PANEL "A" = 150 AMPS, MCB, 120/208V, 30, 4W 277/480. 30 POWER SUPPLY CALCULATIONS: 1. TOTAL DEMAND LOADS = 50.29 KVA 2. DEMAND CURRENT/0 = 61 AMP C' 277/480V,30 3. LT'S PROVIDED POWER SUPPLY = 200 AMPS, 277/48OV, 30, 4W. 4. DESIGNED NEW PANEL "H" = 200 AMPS, 277/480V, 30, 4W. GAS SUPPLY SOLENOID VALVE SHUNT TRIP RELAY CONTROL (1) SEQUENCE OF OPERATION: UPON ACTIVATION OF THE ANSUL SYSTEM, AND /OR FIRE DETECTION SYSTEM. ALL EQUIPMENT UNDER HOOD, AHU UNIT FAN AND GAS SUPPLY SOLENOID VALVE SHALL AUTOMATICALLY SHUT OFF. EXH FANS SHALL BE LOCKED IN "ON" POSITION. DAVID H I ATT ARCHITECT 4410 W. Melrose Avenue Tampa, Florida 33629 p. 813.289.3336 f. 813.289.3332 REGISTERED ARCHITECT DAVID W. t4IATY STATE OF WASHINGTON MAR 1 () 2008 City Of Tukwila D IiLDING DIVISION RIM/ SCHEIDS, CALM AND DETAIL! SHEET NUMBER 1E4 PERVai i CENTER CODE COMKiANCe. NFPA 70 - NEC BAR 1 25c S3 City Of Tukwila BUILDING DWISION CAL S O 1.0 GENERAL 1.1 BIDDERS QUALIFICATIONS AND INSTRUCTIONS: 1.1.1 QUALIFICATIONS: THE BIDDERS SHALL BE QUALIFIED, EXPERIENCED, AND LICENSED ELECTRICAL CONTRACTORS. THEY MUST BE FAMILIAR WITH ALL FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, RULES, AND REGULATIONS THAT MAY, IN ANY MANNER, AFFECT THE TASK. 1.1.2 BIDDING INSTRUCTIONS: BEFORE SUBMITTING THE BID, THE BIDDERS MUST REVIEW THE TENANT INFORMATION AND CRITERIA MANUAL, SPECIFICATIONS, PLANS, DRAWINGS, AND ALL OTHER CONDITIONS AND REQUIREMENTS THAT MAY, IN ANY MANNER AFFECT THE WORK UNDER CONTRACT. THEY MUST VISIT THE SITE OF THE PROPOSED PROJECT TO FAMILIARIZE THEMSELVES WITH THE LOCAL CONDITIONS, FIRE RATING REQUIREMENTS, AND THE NATURE OF THE PROJECT. THE PRICING SHALL BE BASED ON THESE SPECIFICATIONS AND THE MATERIALS SHOWN ON THE DRAWINGS. SUBMISSION OF THE BIDS SHALL BE CONSIDERED AS THE EVIDENCE THAT THE BIDDER IS FAMILIARIZED TO ALL THE FACETS OF THE SPECIFIED PROJECT. CONTRACTOR SHALL USE APPLICABLE SECTIONS OF THIS SPEC. 1.1.3 EXCEPTIONS: ANY EXCEPTIONS, OMISSIONS, DISCREPANCIES, AND DOUBTS REGARDING PLANS, DRAWINGS, AND SPECIFICATIONS, IF ANY, SHALL BE COMMUNICATED PROMPTLY IN WRITING TO THE ARCHITECT OR TO THE ENGINEER FOR THEIR REVIEW AND RESPONSE BACK BEFORE THE BID SUBMISSION DATE. NO ORAL COMMUNICATION REGARDING THE EXCEPTIONS OR CHANGES SHALL BE ACCEPTED. BIDDERS SHALL BE NOTIFIED OF ANY CHANGES, IF MADE, DUE TO THE ACCEPTANCE OF EXCEPTIONS BEFORE THE BID SUBMITTAL DATE. 1.1.4 MATERIAL TAKE OFF: ALL MATERIAL TAKE OFFS, OTHER THAN THE EXISTING DEVICES, SHALL BE MADE USING THE LIGHT & POWER WIRING AND CONDUIT DRAWINGS AND THEIR ASSOCIATED REFERENCES INCLUDING THE SPECIFICATIONS OF THIS PROJECT ON THIS DRAWING. ALL LIGHTING MATERIALS INCLUDING TRANSFORMER, PANELS, FIXTURES, SWITCHES, RECEPTACLES, WIRES AND RACEWAYS, ETC. SHALL BE PURCHASED BY THE CONTRACTORS PER SECTION NO. 2, UNLESS NOTED OTHERWISE. 1.1.5 BID PRICE: THE BID PRICE SHALL INCLUDE LABOR AND MATERIAL COSTS, NECESSARY INSURANCE COSTS AND PERMITS FEES AS REQUIRED TO INSTALL THE COMPLETE ELECTRICAL SYSTEM IN COMPLIANCE WITH THE DESIGN REQUIREMENTS OF THIS PROJECT. 1.1.6 SUCCESSFUL BIDDER: THE SUCCESSFUL BIDDER WILL BE REFERENCED AS THE CONTRACTOR FROM THIS POINT ONWARDS THROUGHOUT THE REST OF THE SPECIFICATION. 1.2 THE ELECTRICAL CONTRACTOR REQUIREMENTS AND INSTRUCTIONS: 1.2.1 THE CONTRACTOR SHALL USE EXPERIENCED AND SKILLED PERSONS TO PERFORM ALL THE ELECTRICAL INSTALLATION WORK UNDER THE CONSTANT SUPERVISION OF LICENSED ELECTRICIANS AND /OR LICENSED JOURNEYMAN ELECTRICIANS. 1.2.2 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL REQUIRED PERMITS, PAYING ALL FEES, AND PROVIDING ALL NECESSARY INSPECTIONS INCIDENTAL TO THE ELECTRICAL PORTION OF THE WORK. 1.2.3 1.2.4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR CARRYING NECESSARY INSURANCE AS REQUIRED BY LAW TO PROTECT EMPLOYEES, OTHER PERSONS, EQUIPMENT, AND MATERIAL. THE INSTALLATION WORK SHALL COMPLY WITH ALL APPLICABLE STATE, COUNTY, AND LOCAL BUILDING CODES. APPLICABLE CODES, AS A MINIMUM, WILL INCLUDE THE LATEST EDITION OF THE FOLLOWING. THESE WILL BE CONSIDERED PART OF THE SPECIFICATION OF Tki1IPDOECTCODE OF THE APPLICABLE CITY AND COUNTY. BB)) NATIONAL ELECTRIC CODE NFPA 70, 2005 C LIFE SAFETY CODE NFPA 101, 2006 D S.B.C.C.I. LATEST EDITION. 1.2.5 IN CASE OF SUBSTITUTIONS THE CONTRACTOR SHALL PROVIDE A WRITTEN REQUEST TO THE ARCHITECT FOR HIS REVIEW . THE CONTRACTOR SHALL IDENTIFY CLEARLY THE DIFFERENCE BETWEEN THE SPECIFIED ITEMS AND THE SUBSTITUTE ITEMS, INCLUDING THE ECONOMIC IMPACT ON THE PROJECT. THE SUBSTITUTE ITEM SHALL NOT BE ORDERED OR USED UNLESS APPROVED BY THE ARCHITECT AND /OR BY THE OWNER IN WRITING. 1.2.6 THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS FOR SPECIFIED PRODUCTS , AT ONE TIME WITHIN THIRTY (30) DAYS FROM THE OFFICIAL NOTICE TO PROCEED. SHOP DRAWING SUBMITTAL SHALL BE MADE FOR THE FOLLOWING MATERIALS AND SYSTEMS: A. LIGHTING FIXTURES, DIMMERS, LAMPS, AND SAFETY SWITCHES. B. TRANSFORMERS, SWITCH BOARDS, DISTRIBUTION PANELS , DISCONNECTS, AND WIREWAYS IF PURCHASED NEW. C. METER CENTERS, CIRCUIT BREAKERS, FUSES, MOTOR STARTERS IF PURCHASED FOR THIS PROJECT. D. TIME CLOCK AND OTHER DEVICES. E) SCHEMATIC DIAGRAMS FOR THE ABOVE ITEMS. 1.2.7 THE CONTRACTOR SHALL PROVIDE FOLLOWING DOCUMENTS BEFORE THE CLOSING OF THE PROJECT AND PRIOR TO THE FINAL PAYMENT: A. ONE YEAR WRITTEN WARRANTY FOR ANY DEFECT IN WORKMANSHIP, MATERIAL, AND EQUIPMENT. B. TWO SETS OF MANUFACTURER'S OPERATIONAL AND MAINTENANCE MANUALS IF APPLICABLE. C. MANUFACTURER'S WARRANTIES AND WARRANTY CERTIFICATES. D. TWO SETS OF REPRODUCIBLE OR RED MARKED UP PRINTS OF "AS- BUILT" DRAWINGS, ONE FOR THE ARCHITECT AND ONE FOR THE OWNER OF THE PROJECT. 1.2.8 THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE THE NECESSARY TEMPORARY ELECTRICAL POWER, AT HIS EXPENSE, AS REQUIRED BY HIS TRADE AND BY THE GENERAL CONTRACTOR. 1.2.9 THE CONTRACTOR SHALL MAKE SURE ON A DAILY BASIS THAT ALL UNNECESSARY MATERIAL AND TRASH CONTRIBUTED BY HIS TRADE ARE REMOVED. 1.2.10 THE CONTRACTOR SHALL CONCEALED ALL THE CONDUIT IN THE FINISHED AREAS. 2.0 PRODUCTS: 2.1 GENERAL: THE ELECTRICAL CONTRACTOR SHALL PURCHASE AND USE ALL "NEW" MATERIAL AS SPECIFIED AND SHOWN ON THE ELECTRICAL PLAN OF THIS PROJECT. ALL THE MATERIAL SHALL BE FREE FROM DEFECTS AND SHALL CARRY A "UL" LABEL. 2.2 CONDUCTORS: ALL INSULATED CONDUCTORS SHALL BE UNCOATED COPPER OF 98% CONDUCTIVITY, 600 VOLT AC, DUAL RATED, TYPE THHN /THWN AS NECESSARY TO MEET THE DESIGN REQUIREMENTS AND THE APPLICABLE CODES. THW (FOR # 4 AWG AND LARGER) AND THERMO PLASTIC WIRES RATED FOR 75 DEGREES CENTIGRADE OPERATIONS IN WET AND DRY LOCATIONS AND 9Q DEGREES CENTIGRADE WITHIN ELECTRIC DISCHARGE LIGHTING EQUIPMENT MAY BE USED. CONDUCTORS NUMBER # 10 AWG AND LOWER SHALL BE SOLID COPPER AND #8 AWG AND ABOVE SHALL BE STRANDED COPPER. THE MINIMUM SIZE OF WIRE SHALL BE # 12 AWG FOR 20 AMP BREAKER, # 10 AWG FOR 30 AMP BREAKER, # 8 AWG FOR 40 AMP BREAKER. 2.3 CABLE:_ SIGNAL CABLES, IF USED, SHALL BE COPPER AND SHALL MEET ALL UL AND N.E.C. CODE REQUIREMENTS. METAL CLAD (TYPE MC), ARMORED (TYPE AC) AND NON- METALLIC (NM) CABLES SHALL NOT BE USED. ALL CABLE ASSEMBLIES SHALL CONTAIN COPPER GROUND CONDUCTOR. 2.4 CONDUITS: THE CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND HOT DIPPED GALVANIZED STANDARD STEEL AS MANUFACTURED BY WHEATLAND TUBE COMPANY OR EQUIVALENT. 2.5 OUTLET BOXES AND FITTINGS: OUTLET BOXES, FITTING CLAMPS AND HANGERS ETC. SHALL BE GALVANIZED STEEL, RUST RESISTANT AND COMPATIBLE WITH THE RACEWAY. OUTLET BOXES FOR FIXTURES, SWITCHES, AND RECEPTACLES SHALL HAVE SMOOTH ROUND EDGES AND SHALL BE WITH COVER PLATES. BOXES SHALL BE "STEEL CITY" OR EQUIVALENT. FITTINGS FOR EMT CONDUITS SHALL BE COMPRESSION TYPE. NO SET SCREW WILL BE USED. UNUSED HOLES SHALL BE COVERED WITH APPROVED INSERT CAPS. 2.6 SWITCHES AND DIMMERS: SWITCHES AND DIMMERS SHALL BE TOTALLY ENCLOSED, RATED AT 120/277 VOLTS AC, 20 AMPS, 2000 WATTS WITH GRAY TOGGLE AND DEVICE PLATE. THESE SHALL BE QUIET OPERATION, COMMERCIAL GRADE AS MANUFACTURED BY LEVITON, LUTRON OR EQUIVALENT. PLATES SHALL MATCH THE SWITCHES. FURNISH IN GANGS AS NECESSARY. 2.7 RECEPTACLES: RECEPTACLE SHALL BE COMMERCIAL GRADE, 125 VOLTS AC, AND 20 AMPERE RATING WITH GROUNDED POLE AND TWO CIRCUIT OPTION, AS MANUFACTURED BY LEVITON OR EQUIVALENT. PLATES SHALL MATCH THE RECEPTACLES. FURNISH IN GANGS AS NECESSARY. 2.8 DEVICE PLATES: PROVIDE DEVICE PLATE FOR EACH AND EVERY OUTLET BOX. FURNISH IN GANGS AS NECESSARY. PLATES AND SCREWS SHALL BE GRAY UNLESS THE OWNER PREFERS SOME OTHER COLOR, AND SHALL BE OF THE SAME MANUFACTURER AS OF THE DEVICES. 2.9 BALLASTS: BALLASTS FOR FLUORESCENT FIXTURES SHALL BE RAPID START, SYLVANIA ELECTRONIC ENERGY SAVING, HIGH POWER FACTOR AND SHALL BE CLASS "P," CBM, TITLE 24 CERTIFIED WITH INTERNAL THERMAL PROTECTOR WITH AUTOMATIC RESET AND CLASS "A" SOUND RATING NOISE LEVELS LESS THAN 30 dB MAXIMUM. BALLASTS SHALL BE MANUFACTURED BY SYLVANIA AS SHOWN ON THE LIGHTING SCHEDULE OR EQUAL EQUAL AND SHALL SHALL BE GUARANTEED AT LEAST FOR FIVE (5) YEARS OF OPERATION AFTER THE ACCEPTANCE. THE BALLAST MODEL NUMBER SHALL BE "2 OR 4 LAMP PSX -SYL Xtreme AS REQUIRED ". 2.10 LAMPS: LAMPS SHALL BE MANUFACTURED BY SYLVANIA MODEL # SYL "F028 /841XP /SS /ECO OR EQUIVALENT. ALL LAMPS SHALL BE GUARANTEED FOR AT- LEAST 4 YEARS OF OPERATION AFTER THE ACCEPTANCE. 2.11 LIGHTING DEVICES: ALL LIGHTING FIXTURES, EMERGENCY & EXIT LIGHTS SHALL BE AS LISTED ON THE LIGHT FIXTURE SCHEDULE; HOWEVER BEFORE PURCHASING ANY LIGHT FIXTURES, SUBMIT FIXTURE. CUT SHEETS FOR THE ARCHITECT AND THE OWNER'S APPROVAL 2.12 TIME CLOCK OR TIME SWITCH: TIME CLOCK SHALL BE ELECTRO - MECHANICAL 24 HOURS SEVEN DAYS TYPE WITH RESERVE POWER AND CONTACTS RATED 40 A. 4 PST AND N.E.M.A. TYPE 1 OR 3R ENCLOSURE. IT SHALL BE SELF POWERED BY A SELF STARTING SYNCHRONOUS MOTOR WITH MINIMUM 16 HR SPRING DRIVEN RESERVE POWER AND A DAY OMITTING DEVICE. TIME CLOCK SHALL BE PARAGON 7007 -0, TORK "W" SERIES, OR APPROVED EQUAL. 2.13 GUARANTEE: ALL ELECTRICAL EQUIPMENT, MATERIAL AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF ACCEPTANCE. 3.0 INSTALLATION INSTRUCTIONS: 3.1 GENERAL: THE PLAN LOCATION OF LIGHTING FIXTURES, JUNCTION BOXES, CONVENIENCE OUTLETS, AND PANEL BOARDS ARE APPROXIMATE UNLESS DIMENSIONED AND ARE TO BE ADJUSTED BY THE CONTRACTOR AS REQUIRED IN THE AREAS WHERE CEILING GRID AND OTHER OBSTRUCTIONS DETERMINE FIXTURE LOCATIONS. THE CONTRACTOR SHALL COORDINATE WITH OTHER ARCHITECTURAL, MECHANICAL AND OTHER SYSTEMS TO AVOID INTERFERENCE. ALL CUTTING AND CONSEQUENT REPAIRS IN CONJUNCTION WITH THE WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. BEAMS OR OTHER STRUCTURAL COMPONENT SHALL NOT BE CUT WITHOUT THE KNOWLEDGE AND WRITTEN CONSENT OF THE ARCHITECT. 3.2 THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MATERIALS, LABOR, TRANSPORTATION, RIGGING & HOISTING, TOOLS, AND STORAGE, ETC. FOR ALL WORK INDICATED AND REQUIRED FOR COMPLETE INSTALLATION. 3.3 THE ELECTRICAL WORK SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE CODES AND SHALL INCLUDE COMPLETE TESTING OF ALL EQUIPMENT AND WIRING. WORKMANSHIP SHALL BE THE HIGHEST QUALITY AS ESTABLISHED BY TRADE STANDARD. 3.4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING NECESSARY PERMITS AND COMMUNICATIONS WITH THE LOCAL BUILDING DEPARTMENT AND INSPECTION PERSONNEL TO REVIEW CONTRACT DOCUMENTS PRIOR TO INSTALLATION. 3.5 OWNER WILL NOT BE HELD RESPONSIBLE FOR FIELD CHANGES THAT ARISE FROM CONTRACTOR'S ERROR OR OMISSION OF MATERIALS OR WORKMANSHIP IN WORK PERFORMANCE. 3.6 THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF ALL UTILITIES PLACEMENT, AS IDENTIFIED ON THE RISER DIAGRAM, AND LOCATION OF THE ELECTRICAL SERVICE EQUIPMENT. THE CONTRACTOR SHALL PAY ALL NECESSARY CHARGES ASSOCIATED WITH INSTALLATION OF ALL UTILITIES TO THE POWER COMPANY PRIOR TO THE CONSTRUCTION. A LETTER SHALL BE PROVIDED FROM THE POWER COMPANY THAT ALL THE CHARGES HAVE BEEN PAID IN FULL. 3.7 NECESSARY AND OBVIOUSLY REQUIRED, ELECTRICAL ITEMS THAT ARE NOT SHOWN ON THE DRAWINGS, SHALL NOT RELIEVE THE CONTRACTOR OF HIS RESPONSIBILITIES TO INSTALL A COMPLETE AND SAFE ELECTRICAL SYSTEM. 3.8 THE ELECTRICAL CONTRACTOR SHALL FOLLOW THE SAME COLOR CODE IDENTIFICATION FOR EACH PHASE THROUGHOUT THE SYSTEM FROM SERVICE SWITCH OR TRANSFORMER THROUGH ALL BRANCH CIRCUITS. 3.9 ALL SLAB OR ROOF PENETRATIONS SHALL BE MADE WITH APPROVED FIRE RATED SMOKE BARRIER FITTINGS. PROVIDE ACCESSORIES (PITCH POCKETS, SLEEVES, ETC.) AS REQUIRED. 3.10 JUNCTION BOXES FOR NEON SIGN LIGHTS, SWITCHES, UGHTING FIXTURES, RECEPTACLES AND FOR PULLING WIRES SHALL BE AS APPROXIMATE AS SHOWN ON THE PLANS BUT EXACT LOCATIONS SHALL BE GOVERNED BY THE ARCHITECTURAL PLANS. 3.11 ALL OUTLET BOXES SHALL HAVE SQUARE CUT CORNERS. AIR SPACE GREATER THAN 1/8" AROUND OUTLET BOXES, AND ADJACENT DRYWALL WILL NOT BE PERMITTED. THE CONTRACTOR SHALL COORDINATE WITH DRYWALL INSTALLER PRIOR TO INSTALLATION. CAULK AROUND BOXES TO ELIMINATE STEEL OUTLET. 3.12 LIGHTING SWITCHES AND CONVENIENCE RECEPTACLES SHALL BE FLUSH MOUNTED IN SECTIONAL SWITCH BOXES WITH MATCHING COVER PLATES UNLESS NOTED OTHERWISE. 3.13 THE MOUNTING ARRANGEMENT OF EACH FIXTURE WILL BE DETERMINED BY THE CONTRACTOR EXCEPT WHERE THE MANUFACTURER HAS GIVEN SPECIFIC MOUNTING INSTRUCTIONS. 3.14 THE CONTRACTOR SHALL FURNISH AND INSTALL ALL LUMINARIES, DEVICES, AND EQUIPMENT AS SPECIFIED AND SHOWN ON THE PLAN DIAGRAMS. PROVIDE ALL CABLES, CONDUCTORS, CONDUITS, AND CONNECTIONS AS REQUIRED TO PROVIDE COMPLETE AND OPERATIONAL ELECTRICAL AND MECHANICAL SYSTEMS. ALL CONDUITS SHALL BE RUN CONCEALED IN FINISHED AREAS. 3.15 INDIVIDUAL BREAKERS WILL SUPPLY ELECTRICAL POWER TO INDIVIDUAL SIGN OR NEON LIGHT CIRCUITS. NEON TRANSFORMER EQUIPMENT IS TO BE CONCEALED ABOVE ADJACENT COLUMN ENCLOSURE OR TO BE INSTALLED AS SHOWN ON ARCHITECTURAL DRAWINGS. 3.16 ALL JOINTS IN CONDUIT AND RACEWAY SHALL BE MADE TIGHT AND BENDS SHALL BE MADE OVER LONG RADIUS WHERE ENTERING A CABINET AND JUNCTION BOX. THE CONTRACTOR SHALL SUPPORT ALL CONDUIT AND RACEWAYS SECURELY FROM JOISTS AND /OR BEAMS (TIE WIRES ARE NOT ACCEPTABLE). THE CONTRACTOR SHALL VERIFY ALL RACEWAY SIZES IN ACCORDANCE WITH THE N.E.C. CODE. NO CONDUIT SHALL CARRY MORE THAN THREE (3) CURRENT CARRYING CONDUCTORS. NOTE: ALL JOB CUT THREADS SHALL BE COATED WITH RUST RESISTANT ZINC CHROMATE FOR THIN WALL EMT. 3.17 LIGHTING CONDUITS SHALL BE SUPPORTED AT EVERY 8 FEET. 3.18 MOUNTING HEIGHT OF LIGHTING EQUIPMENT, UNLESS NOTED OTHERWISE ON ARCHITECTURAL PLANS SHALL BE APPROXIMATELY AS FOLLOWS: A. LIGHTING SWITCHES CENTERLINE B. CONVENIENCE OUTLETS CENTERLINE C. LIGHTING & POWER PANELS TOP D. EMERGENCY LIGHT FIXTURES 4 FEET ABOVE A.F.F 1 FEET, 6 INCHES A.F.F 6 FEET, 6 INCHES ABOVE A.F.F 9' ABOVE A.F.F TO BOTTOM OF THE UNIT. 3.19 ELECTRICAL RACEWAYS AND SHALL BE SIZED IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (N.E.C.), ARTICLE 250. ALL BRANCH CIRCUITS SHALL HAVE A SEPARATE GREEN INSULATED GROUND WIRE IN EACH CONDUIT RUN. ISOLATED GROUND CONDUCTORS SHALL BE ROUTED TO THOSE CIRCUITS WHICH NEED ISOLATED GROUND SPECIALLY FOR COMPUTERS AND CASH REGISTERS. 3.20 THE CONTRACTOR SHALL PROVIDE LIGHTNING PROTECTION VOLTAGE SURGE PROTECTOR FOR ALL SERVICE PHASE CONDUCTORS TO GROUND (IF IT IS NOT ALREADY THERE IN CASE OF RENOVATIONS). DEVICE SHALL BE APT TE 400 OR APPROVED EQUIVALENT. 3.21 LUMINARIES SHALL BE AS SPECIFIED IN THE "LIGHTING FIXTURE SCHEDULE ". ALL RECESSED AND LAY -IN FIXTURES SHALL BE SUPPORTED FROM THE FOUR CORNERS WITH SUPPORTS CAPABLE OF CARRYING TWICE THE WEIGHT OF THE FIXTURE. ALL SUPPORTS SHALL BE ATTACHED TO THE JOISTS AND /OR BEAMS. NO LIGHTING FIXTURE SHALL BE INSTALLED WITHIN 2 FEET OF ANY SPRINKLER HEAD. 3.22 THE CONTRACTOR SHALL INSTALL ALL TELEPHONE JACKS AND WIRING FROM THE MAIN TELEPHONE TERMINAL BOARD TO THE FINAL TELEPHONE OUTLETS. WIRING SHALL BE INSTALLED IN A MINIMUM 1/2 INCH CONDUIT. 3.23 3.24 3.25 THE CONTRACTOR SHALL COORDINATE WITH THE FIRE PROTECTION CONTRACTOR AND SHALL MAKE ALL NECESSARY CONNECTIONS BETWEEN DUCT SMOKE DETECTORS AND HVAC UNITS. ALL JUNCTION BOXES SHALL BE ACCESSIBLE FROM BELOW. OTHERWISE, CONTRACTOR SHALL PROVIDE ACCESS PANEL AT ALL JUNCTION BOX LOCATIONS AND SMOKE DETECTORS. IF NOT ALREADY EXISTING, THE CONTRACTOR SHALL FURNISH ALL THE NECESSARY DISCONNECT SWITCHES, RELAY BOXES, AND CONTROL BOXES AS REQUIRED AND RECOMMENDED BY THE HVAC MANUFACTURER FOR THE HVAC UNIT AND WATER HEATER. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH THE MECHANICAL CONTRACTOR AND MAKE ALL NECESSARY CONNECTIONS TO MAKE THE HVAC SYSTEM FUNCTIONAL. 3.26 A PLASTIC COVERED TYPE WRITTEN IDENTIFICATION CARD FOR ALL MAIN AND BRANCH CIRCUITS INCLUDING SPARES SHALL BE POSTED AT THE INSIDE OF THE PANEL DOOR. 3.27 LOCK-ON DEVICES ON PANEL CIRCUIT BREAKERS FOR NIGHT, EXIT AND EMERGENCY LIGHTING CIRCUITS SHALL BE PROVIDED AND THE SHALL BE GIVEN TO THE OWNER. 4.0 TRANSFORMER AND PANEL BOARD SPECIFICATIONS THIS SECTION SHALL APPLY TO THE NEW TRANSFORMER, PANEL BOARDS, CIRCUIT BREAKERS, PANEL BOXES & TRIMS, DISCONNECT SWITCHES, AND FUSES. 4.1 PANEL BOARDS: PANEL BOARDS SHALL BE GENERAL PURPOSE N.E.M.A. TYPE 1 OR TYPE 3R ENCLOSURES SUITABLE FOR SPECIFIED INDOOR OR OUT DOOR LOCATIONS AND AND FLUSH OR SURFACE MOUNTING APPLICATIONS AS INDICATED ON THE PANEL SCHEDULE. PANEL BOARDS AND THE INTERNAL COMPONENTS SHALL BE RATED TO PERFORM THEIR FUNCTIONS CONTINUOUSLY AT 40'C AMBIENT AND 50% RELATIVE HUMIDITY. BUSSES, TERMINALS, AND LUGS SHALL BE RATED AND CAPABLE TO FUNCTION CONTINUOUSLY AT 75 DEGREES CENTIGRADE. PANEL BOARDS SHALL BE AS MANUFACTURED BY WESTINGHOUSE ELECTRIC CORP., GENERAL ELECTRIC, SQUARE 'D', CHALLENGER, OR APPROVED EQUAL. A NAMEPLATE LISTING PANEL NUMBER, TYPE, MANUFACTURER'S NAME, NUMBER OF PROTECTIVE AND SWITCHING DEVICES, VOLTAGE, CURRENT, PHASE AND AIC RATINGS SHALL BE PROVIDED. BRANCH CIRCUITS SHALL BE ARRANGED USING DOUBLE ROW CONSTRUCTION. ALL INTERIORS SHALL BE COMPLETELY FACTORY ASSEMBLED WITH SWITCHING AND PROTECTIVE DEVICES, WIRE CONNECTORS, ETC. ALL WIRE CONNECTORS, EXCEPT SCREW TERMINALS, SHALL BE OF THE ANTI -TURN SOLDERLESS TYPE AND ALL SHALL BE SUITABLE FOR COPPER WIRE OF THE SIZES INDICATED ON DRAWINGS OR IN THE PANEL SCHEDULES AND CONTINUOUSLY FUNCTIONING AT 75 DEGREE CENTIGRADE. ALL BREAKERS, SIZED AS SHOWN ON PANEL SCHEDULE, SHALL BE BOLT -ON BREAKERS. INTERIORS SHALL BE SO DESIGNED THAT SWITCHING AND PROTECTIVE DEVICES CAN BE REPLACED WITHOUT DISTURBING ADJACENT UNITS AND WITHOUT REMOVING THE MAIN BUS CONNECTORS AND SHALL BE SO DESIGNED THAT CIRCUITS MAY BE CHANGED WITHOUT MACHINING, DRILLING, OR TAPPING. BUS BARS FOR THE MAINS SHALL BE OF COPPER AND SIZED IN ACCORDANCE WITH UNDERWRITERS' LABORATORIES STANDARDS. UNLESS NOTED OTHERWISE, FULL SIZE NEUTRAL BARS SHALL BE INCLUDED. BUS BAR TAPS FOR PANELS WITH SINGLE POLE BRANCHES SHALL BE ARRANGED FOR SEQUENCE PHASING OF THE BRANCH CIRCUIT DEVICES. THE SHORT CIRCUIT RATING OF THE ASSEMBLED PANEL BOARD SHALL BE IN ACCORDANCE WITH UL. INC. STANDARDS AND THEIR TEST VERIFICATION. PHASE BUSSING SHALL BE FULL HEIGHT WITHOUT REDUCTION. CROSS AND CENTER CONNECTORS SHALL BE COPPER. NEUTRAL AND GROUND BUSSING SHALL HAVE SUITABLE LUGS FOR OUTGOING FEEDERS REQUIRING A NEUTRAL AND GROUND CONNECTIONS. SPACES FOR FUTURE SWITCHING AND PROTECTIVE DEVICES ON LIGHTING AND APPLIANCE DISTRIBUTION PANELS SHALL BE BUSSED FOR THE MAXIMUM DEVICE THAT CAN BE FITTED INTO THEM. PROVIDE BLANK FILLER PLATES IN THE EMPTY SPACES. 4.2 CIRCUIT BREAKER: THE CIRCUIT BREAKERS ARE TO BE INDUSTRIAL MOLDED CASE BOLT ON TYPE, STANDARD THERMAL, MAGNETIC, WITH TRIP FREE MECHANISM, THREE POSITION HANDLES INDICATING "ON" "OFF" AND "TRIPPED" CONDITION. EACH POLE SHALL PROVIDE INVERSE TIME DELAY AND INSTANTANEOUS CIRCUIT PROTECTION. THE BREAKER RATING AND CONFIGURATION SHALL BE AS INDICATED ON THE PANEL BOARD SCHEDULE. ALL MULTI POLE BREAKERS SHALL HAVE AN INTERNAL COMMON TRIP. ALL BREAKER LUGS SHALL BE SUITABLE TO WITHSTAND 75 DEGREE CENTIGRADE WITHOUT MALFUNCTIONING. 4.3 PANEL TRIM: HINGED DOORS IN PANEL TRIMS SHALL COVER ALL SWITCHING DEVICE HANDLES AND SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: 1. DOORS SHALL NOT UNCOVER ANY UVE PARTS WHILE MAKING SWITCHING DEVICE HANDLES ACCESSIBLE. 2. DOORS SHALL HAVE FLUSH -TYPE CYLINDER LOCK AND CATCH, EXCEPT THAT DOORS OVER 48" IN HEIGHT SHALL HAVE AUXILIARY FASTENERS AT TOP AND BOTTOM OF DOOR IN ADDITION TO FLUSH -TYPE CYLINDER LOCK AND CATCH. DOOR HINGES SHALL BE CONCEALED. ALL LOCKS SHALL BE KEYED ALIKE. DIRECTORY FRAME AND CARD HAVING A TRANSPARENT COVER SHALL BE FURNISHED ON EACH DOOR. THE TRIMS SHALL BE FABRICATED FROM CODE GAUGE SHEET STEEL ALL EXTERIOR AND INTERIOR STEEL SURFACES OF THE PANEL BOARDS SHALL BE PROPERLY CLEANED PRIMED AND PAINTED IN ACCORDANCE WITH THE MANUFACTURER'S STANDARD SPECIFICATIONS AND COLOR. TRIMS FOR FLUSH MOUNT PANELS SHALL OVERLAP THE BOX BY AT LEAST 3/4" ALL AROUND. SURFACE MOUNT PANELS TRIMS SHALL HAVE THE SAME WIDTH AND HEIGHT AS OF THE BOX. TRIMS SHALL BE MOUNTABLE BY A SCREW DRIVER WITHOUT THE NEED FOR SPECIAL TOOLS. 4.4 PANEL BOXE BOXES SHALL BE MADE FROM UNPAINTED GALVANIZED CODE GAUGE STEEL HAVING MULTIPLE KNOCKOUTS ON THE TOP AND THE BOTTOM EXCEPT WHERE NOTED OTHERWISE. BOXES SHALL BE OF SUFFICIENT SIZE TO PROVIDE A MINIMUM GUTTER SPACE OF 4" ON ALL SIDES. WHERE FEEDER CABLES SUPPLYING THE MAINS OF A PANEL ARE CARRIED THROUGH ITS BOX TO SUPPLY OTHER ELECTRICAL EQUIPMENT, THE BOX SHALL BE SO SIZED AS TO INCLUDE THIS WIRING SPACE. THIS WIRING SPACE SHALL BE IN ADDITION TO THE MINIMUM GUTTER SPACE SPECIFIED ABOVE AND THE LIMITING WIDTH MAY BE INCREASED ACCORDINGLY. AT LEAST FOUR (4) INTERIOR MOUNTING STUDS SHALL BE PROVIDED. ALL UNUSED HOLES IN THE BOXES SHALL BE PLUGGED WITH APPROVED INSERT CAPS. BOXES SHALL BE "STEEL CITY" OR EQUAL. 4.5 DISCONNECT SWITCHES: THE CONTRACTOR SHALL INSTALL N.E.M.A. TYPE 1 DISC. SWITCHES FOR INDOOR AND N.E.M.A. TYPE 3R DISC. SWITCHES FOR OUT DOOR APPLICATIONS. ALL DISCONNECT SWITCHES FOR SERVICE CONDUCTOR ENTRANCES SHALL BE RATED AT LEAST 100K AIC. DISCONNECT SWITCHES FOR MOTOR CIRCUIT AND FIXED LOAD (SUCH AS HVAC EQUIPMENT, AND WATER HEATER ETC.) CIRCUITS SHALL BE FUSIBLE OR NON FUSIBLE AS SHOWN ON THE DRAWINGS OR REQUIRED BY THE MANUFACTURER. 4.6 FUSE: THE CONTRACTOR SHALL USE DUAL ELEMENT, TIME DELAY CURRENT LIMITING, 100,000 AMP AIC RATED, CLASS RK -1 FUSES WHEN PROTECTING PANEL BOARDS AND TRANSFORMERS AND 100,000 AMP AIC RATED CLASS RK -5 FUSES WHEN PROTECTING MOTORS UNLESS NOTED OTHERWISE OR REQUIRED DIFFERENTLY BY THE MANUFACTURER. ALL FUSES IN ANY DISC.. SW SHALL BE OF THE SAME MANUFACTURER AND SHALL BE MANUFACTURED BY BUSSMANN, GOULD SHAWMUT OR EQUIVALENT. .EL01•-- 161 FEB 15 ZOO PER v i E Ew a` -' 1 . DATE: 12 -24 -07 JOB NO: 0734 DRAWN: CHECKED: REVISIONS DAVID HIATT ARCHITECT 4410 W. Melrose Avenue Tampa, Florida 33629 p. 813.289.3336 f. 813.289.3332 REGISTERED ARCHITECT DAVID W. HIATT STATE OF WASHINGTON ELECTRICAL SPECIFICATIONS SHEET NUMBER 1E4