HomeMy WebLinkAboutPermit EL08-0158 - WESTFIELD SOUTHCENTER MALL - CLARKSCLARKS
466 SC MALL
07 -19.08
ELO8-158
CitAbf Tukwila •
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 6364200010
Address: 466 SOUTHCENTER MALL TUKW
Suite No:
ELECTRICAL PERMIT
Permit Number: EL08 -158
Issue Date: 06/10/2008
Permit Expires On: 12/07/2008
Tenant:
Name: CLARKS
Address: 466 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: DAVID A LEVY Phone: 330 666 -6767
Address: 345 SPRINGSIDE DR , AKRON OH
Contractor:
Name: M K ELECTRIC INC
Address: PO BOX 612 , BUCKLEY WA
Contractor License No: MKELEKE957PO
Phone: 360 -829 -5362
Expiration Date: 10/20/2009
DESCRIPTION OF WORK:
Value of Electrical:
$35,000.00
Fees Collected:
$820.00
Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature: •
I hereby certify that I have read and
Hvk
Date: UtA t,01 4
ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the erfo c f wo k. I am authorized to sign and obtain this electrical permit.
Signature: 6Zi t.�!LD /D Date: /0
Print Name: ��`�" /�'S ?er/11.s./
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -158 Printed: 06 -10 -2008
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Parcel No.: 6364200010
Address: 466 SOUTHCENTER MALL TUKW
Suite No:
Tenant: CLARKS
PERMIT CONDITIONS
Permit Number: EL08 -158
Status: ISSUED
Applied Date: 02/19/2008
Issue Date: 06/10/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Signature:
Print Name: / J ��- VOS7t�/ GC�i
Date: / 4912
doc: Cond -Elec
EL08 -158 Printed: 06 -10 -2008
i
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Electrical Permit No. euvii.- tc2
Project No.
Pos- o1[0
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: L oA2.0 - Opp C�
Site Address: Alp 'Gila\\ Suite Number: kfiNgilio Floor:
Tenant Name: C \ac 'S
Property Owners Name: v ie.\fcie, cA
MailingAddress:W \tppA ■►\t \CC_ \` . -V \aer L'Angeks X0025
City tIt State Lip
New Tenant: ❑
Yes
❑..No
CONTACT PERSON - Who do we contact when your permit is ready to be issued
-T0 be. (e�recmtne c4
Name: J.a.V 1 A Let,
Mailing Address: 3L* S r'i rtS 1 d e b le
E -Mail Address:
Day Telephone:
Akrao
City
M- iE43
State Zip
Fax Number: 33a - L(04.
ELECTRICAL CONTRACTOR INFORMATION —'T> oe.
Company Name:
Mailing Address:
City State Zip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): S ,,r.� CX�� . Cs0
Scope of Work (please provide detailed information):
9(.4. i falevd i Stuff l es -rare ` r e r,a..n.'i- Z rn p rvV e-m .if a n C la r k.S
p
Will service be altered? ❑ Yes Et No Adding more than 50 amps? ❑ Yes [` No
Type of Use:
Type of work:
❑ New ❑ Addition ❑ Service Change ❑ Remodel [Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
Xl""uget Sound Energy
❑ Seattle City Light
II 'ipphcattens \Fern.- Apphcuions On I me 4 -7111: - I-k..ln<al perms Apphcation.doc
bh
Page 1 of
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings 5140.00
(including an attached garage)
❑ Garages, pools. spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm. furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added /altered circuits)
❑ Service change with added /altered circuits $75.00
number of added circuits S 10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added /altered without service change S50.00
(6 or more circuits) $7.00 ca
❑ Meter mast repair $65.00
❑ Low voltage systems S55.00
(alarm, furnace thermostat)
MULTi- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured /mobile home service S80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
i HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THiS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THiS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name: MA1�t -, > t FE.DDIcz, -b
Mailing Address: e33 cS. o4 C.+ Fee ,Trai le-e" *3
Day Telephone:
kw; 1a.
City
Date: 2111/or
2. 44, - 4:TD Z - 4,..e)-1
WA 9 8181
State Lip
Date Application Accepted:
►,91.[t
H 'Apphcaionsronn - Application. Un I ire 4 -200" - hleancal Permit 'lpphcatuon.Joc
bh
Date Application Expires: a I (1.
Staff Initials:
Page 2 of 2
SET RECEIPT
RECEIPT NO: R08 -02032
Initials: JEM
User ID: 1165
Payee: SCOTT THOMAS CONSTRUCTION
Payment Date: 06/09/2008
Total Payment: 3,129.00
SET ID: 0304A
SET TRANSACTIONS:
Set Member Amount
D08 -089 1,848.75
yEL0T8158' 656.00
M08 -044 556.25
PGO8 -047 68.00
TOTAL: 1,848.75
TRANSACTION LIST:
Type Method
Description
SET NAME: CLARKS
Amount
Payment
Check 157397
ACCOUNT ITEM LIST:
Description
TOTAL:
Account Code
3,129.00
3,129.00
Current Pmts
BUILDING - NONRES
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLAN CHECK - NONRES
PLUMBING - NONRES
STATE BUILDING SURCHARGE
000/322.100
000.322.101.00.0
000.322.102.00.0
000/345.830
000.322.103.00.0
000/386.904
TOTAL:
1,784.25
656.00
451.00
165.25
68.00
4.50
3,129.00
3421 06/09 9711 TOTAL 3129.00
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http.• //www. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R08 -00458
Initials: JEM Payment Date: 02/19/2008
User ID: 1165 Total Payment: 1,524.55
Payee: DAVID A LEVY & ASSOCIATES
SET ID: S000000961 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08 -089 1,321.05
i EL'`08 .V 164.00
M08 -044 7.50
PG08 -047 32.00
TOTAL: 1,524.55
TRANSACTION LIST:
Type Method Description Amount
Payment Check 11959 1,524.55
TOTAL: 1,524.55
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - NONRES
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000/322.100 97.75
000.345.832.00.0 164.00
000/345.830 1,262.80
TOTAL: 1,524.55
37 90 02/1q 1710 TOTAL 1521-.55
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION R.
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
tp,
Type of Inspecti
!
Ad }
/9 k
Date Called:
Special Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
oved per applicable codes. Corrections required prior to approval.
COMMENTS:
fr/it/2L-
Ins pe /tL 601W.2i241/�v f/
Dat //9 J
El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
e
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 9
Project: ex. Alex 1 >
Type of Inspection:
�00
r ,eF kS
Address: Li up
Date Called:
— 'JO pi tE p4y„I q coct6.tr c airl
CbdNk_Teh t,) I K1 Cod Nei-r 'Ai (fk-du1
Special Instructions:
Date Wanted:
- v Qt IJCt. QVrit 1Z C' t c s t r
tea t le
p.m.
Requester:
P
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
— 1I [(46( 1n't 1403tL5 midPmt
r ,eF kS
— 'JO pi tE p4y„I q coct6.tr c airl
CbdNk_Teh t,) I K1 Cod Nei-r 'Ai (fk-du1
Q wk _ rI fur L cou,..lp /a
2 4.3 1,4 lea avectot7
- v Qt IJCt. QVrit 1Z C' t c s t r
‹ . Co , 5 RAJ 24 P t
5 J P.Pagt.fr tic-
Inspector:
(3044/(X,
JDate: Di /rg/s
JJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
Project: �� ��
Type of Inspection:
2400
Address: �g 6 �
Date Called:
Special Instrrictions:
Date Wanted:
1 /I?
Requester:
��
Phone No:
ElApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
07 17
Date: /CA'
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
iarsli anbi,sYwx Ie.... 1, • .. .
INSPECTION NO.
INSPECTION RECORD it,� _ S�
Retain a copy with permit c
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION e
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: ��� � �
Type of Inspection: 2-100
Address:
64 M".'pm/
Date Called:
Special Ins uctions:
Date Wanted:
t
7/i i
P.m.
Requester:
J
Phone No:
Approved per applicable codes. U Corrections required prior to approval.
COMMENTS:
Inspector:
b0ate A? (I 1 O\S)
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
- 1..- _ ...m.WINROF` ----^3 s-"- - r - - .16.wLale • nee ti alOLostebr. M.,.,•01%.
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
toy- r
PERMIT NO.
(206)431 -3670
Project:4�
Type of Inspection: 703
Address: Litt rite/t,
Date Called:
Special Instructions:
Date Wanted:
f
/ L
p.r
p.m.
Requester:
Phone No:
Approved per applicable codes. 0 Corrections required prior to approval.
'COMMENTS:
— wits uski Covet
e \OJ(.o} IN
'Inspector:
Date: 61 119 j',
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
(Date:
d.� 4
INSPEC%N NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO_
CITY OF TUKWILA BUILDING DIVISION -
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
Project: f�
Ty1:76rgctio .3
Vo
Dattee Called:
Special Instructions:
Date Wanted: ,
(..'-/S7
Requester:
Phone No:
proved per applicable codes. El Corrections required prior to approval.
4 oMMEN -rm — —700/
p/4 — (st/ A A f 3
7 0 -6 s
/04
c),<
--- . p f/ �t• 1 5( FP/ r
9-G c)ai, v J.
0
-__ Ai -s---/ inn - 1-1-"Ari I / 6
Inspe
=;i1 /( %t`iTWH
Datej
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
3
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION e-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
ti
Project:
Type of Inspection:..., 1..7
/
iciiiZZ
Date Called:
f TG/
/x/%25 j--:' /, 6 e / : C✓
Special Instructions:
.
Date Wanted:
' r
2_ 5
Cd
p.m.
Requester:
Phone No:
EjApproved per applicable codes.
rrections required prior to approval.
COMMENTS:
i)/( (U /1 A hi/ 6- ,A1/77
p.otio / i,V C
G %• Cv.iJ if /Al 444.14z,-_5- _ 1 c z,-
f TG/
/x/%25 j--:' /, 6 e / : C✓
Ins pec r Date :W.7_ S /6 r
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
eGre4lx.c.�.. • M. — - �..- --�..J bM. • ai,. i.ae.Y..,.r a�s1i�"rt.�. +iwamosn�;E.• r,. ....te sta,_:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project:
Type of Inspection: C_
Addfess� ,c—C--
i)i, L
Date Called:
Special Instructions:
Date Wanted:
//
Requester:
Phone No:
roved per applicable codes.
Corrections required prior to approval.
COMMENTrJ
69/4_,—
W 1 t c v(I f/ ---
4-Ws/ , 9oC # ,I' /57 4n0/1 %
Inspec /` ` &r1&6/u/Q'I
Date:` //?/i g
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
6 re__ til _ ... i Sw i=•c'1- �U.1 .Y _ _ __ _..� . llxt iY" ti Mi AbAig25a.J.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. P RMIT NO.
CITY OF TUKWILA BUILDING DIVISION le-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project��� 7�
Type of Inspection:
! 6 .5-
q�,/d%� l.�f/
��/
r i u,
Date Called:
Special Instructions:
Date Wanted:6 /, /7
a
Requester:
Phone No:
roved per applicable codes. El Corrections required prior to approval.
OMMENTS:
- SAR/ /��=
Inspe f`Or:
it t-
4yrfig /.i
Date: //7/o,
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
�.,...__. -... -..e, .._. r �....ar.1'.+.�s.�� _�. a ..&am,
2006 Washin• ton State Nonresidential Ener Code Corns Hance Form
Interior Lighting Summary
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address 466 Southcenter Mall
Date 2/12/2008
#1010
For Building De VO E \pt�
CODE iCQ►{�
NEPA 7C
1�
sAAR 1
Tukwila, WA 98188
Applicant Name: Clarke
Applicant Address:
Applicant Phone:
Project Description
Sales Area
• New Building • Addition 'i Alteration
• Plans Induded
Refer to WSEC Section 1513 for controls and commissioning requiremen
Compliance Option
0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysi B due
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on .
Alteration Exceptions
(check appropriate box - sec. 1132.3)
0.50
2787.0
• No changes are being made to the lighting
Sales Area
& space use not changed.
• Less than 60% of the fixtures new, installed wattage not increased,
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per fr2 "
Area in ft2
Allowed x Area
Sales Area
Retail
1.50
1290.0
1935.0
Sales Area
Additional Retail Note #10
1.50
1290.0
1935.0
Back Room
Storage Area - calculated with racking as shown on pl
0.50
2787.0
1393.5
From Table 15 -1 (over) - document all exceptions on form LTG -LPA
Proposed Lighting Wattage
Total Allowed Watt l 5263.5
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Back Room
Type F - 2lourescent Strip Light
17
62.0
1054.0
Back Room
Type G - Wraparound floureacent
1
62.0
62.0
Back Room
Type BE - Recessed flourescent downlight - emergency
1
28.0
28.0
Sales Area
Type BE - Recessed floureacent downlight - emergency
5
28.0
140.0
Sales Area
Type B - Incandescent downlights
4
75.0
300.0
Sales Area
Type A - Metal Halide pendant fixture
2
84.0
168.0
Sales Area
Type n2 - Metal halide multi -spot fixture
4
88.0
352.0
Sales Area
Type B - Metal halide downlight
21
30.0
630.0
Sales Area
Type TH - Metal halide track head
80
30.0
2400.0
Back Room
Type B - Metal halide downlight
1
30.0
30.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior
Total Proposed Watt sl 5164 .0
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank_ r
FILE COPY
puoiCE
- NEC
20N
Tul�uila
l
C. -. .N
FEB 1 9 2008
2006 Washin ton State Nonresidential Ener Code Come Hance Form
Interior Lighting Summary (back)
2006 Washington State Nonresidential Energy Code Compliance Form
LTG -INT
Revised July 2007
Prescriptive Spaces
Occupancy:
rt Warehouses, storage areas or aircraft storage hangers Other
Qualification Checklist
Note: If occupancy type is "Other" and
fixture answer is checked, the number of
fixtures in the space Is not limited by Code.
Clearly indicate these spaces on plans. If
not qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
1521)
0.9
• Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballas
3. LED lights.
TABLE 15 -1 Unit Lighting Power Allowance (LPA
is
Use'
LPA (W /sf)
Uses
LPA2 (W /sf)
Automotive facility
0.9
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools hospitals. institutions, museums, banks,
churches) "
1.0
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations
1.0
Cafeterias, fast food establishments5,
restaurants/bars5
1.3
Post office
1.1
Dormitory
1.0
Retail75, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only). school
classrooms, day care centers
1.2
Gvmnasias. assembly spaces')
1.0
Theater. motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group I -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses ', storage areas
0.5
Hotel banquet/conference/exhibition hall's
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
'laboratory' shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Librariess
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies' (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms. elevator lobbies
0.8
Footnotes for Table 15 -1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Reserved.
7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used.
8) Reserved.
9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W/ft2.
10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points
of track attachment).
c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
2006 Washin ton State Nonresidential Ener Code Com•liance Form
•
Lighting Power Allowance Adjustments
2008 Washington State Nonresidential Energy Code Compliance Forms
LTG -LPA
Revised July 2007
Project Address 1466 Southcenter Mall
!Date
1/29/2008
Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances fo interior lighting. The
Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet,
12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts
per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per2f1location on LTG -SUM.
Adjusted Lighting Power Allowances (Interior)
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per f? **
Ceiling Height
for this room
Ceiling Height limit
for this exception"
Adjusted LPA
Watts per t?
** From Table 15 -1 based on exceptions listed in footnotes
Li'jhting,
2008 Washington State
Motor, and Transformer Permit Plans Checklist
LTG -CHK
Nonresidential Energy Code Compliance Forms Revised July 2007
Project Address 466 Southcenter Mall
(Date 2/12/2008
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the
2006 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Requirec
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
E100
yes
1513.2
Area controls
Maximum limit per switch
8100
yea
1513.3
Daylight zone control
Schedule with type and features, indicate locations
8100
yea
vertical glazing
Indicate vertical glazing on plans
8100
n.a.
overhead glazing
Indicate overhead glazing on plans
yes
1513.4
Display /exhib /special
Indicate separate controls
5100
1513.5
Exterior shut -off
Schedule with type and features, indicate location
n.a.
(a) timer w /backup
Indicate location
n.a.
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
n.a.
1513.6.1
(a) occup. sensors
Schedule with type and locations
a. a.
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
n.a.
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
EXIT SIGNS (Section 1514)
yes I
1514 IMax,
watts 'Indicate
watts for each exit sign 18400
I
LIGHTING POWER ALLOWANCE (Section 1530 -1532)
yes
1531
Interior Lighting
Summary Form
Completed and attached. Schedule with fixture type
lamps, ballasts, watts per fixture
n.a.
1532
Exterior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
MOTORS (Section 1511)
U.S. I
1511 IElec
motor efficiency IMECH
-MOT or Equipment Schedule with hp, rpm, efficiency I
TRANSFORMERS (Section 1540)
yes I
1540 'Transformers
'Indicate
size and efficiency 1E200
I
If "no" is circled for any question, provide explanation:
Li jhting, Motor, and Transformer Permit Plans Checklist LTG -CHK
2008 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Lighting - General Requirements
1613 Lighting Controls: Lighting, including exempt lighting
in Section 1512, shall comply with this section. Where
occupancy sensors are cited, they shall have the features
listed in Section 1513.6.1. Where automatic time switches
are cited, they shall have the features listed in Section
1513.6.2.
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling- height partitions, shall be
provided with lighting controls located within that space. The
lighting controls, whether one or more, shall be capable of
turning off all lights within the space. The controls shall be
readily accessible, at the point of entry/exit, to personnel
occupying or using the space.
EXCEPTIONS: The following lighting controls may be
centralized in remote locations:
1. Lighting controls for spaces which must be used as
a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that
may be controlled from a single switch or automatic control
shall not exceed that which is provided by a 20 ampere circuit
loaded to not more than 80 %. A master control may be
installed provided the individual switches retain their capability
to function independently. Circuit breakers may not be used
as the sole means of switching.
EXCEPTIONS: 1. Industrial or manufacturing process
areas, as may be required for production.
2. Areas less than 5% of the building footprint for
footprints over 100,000 ft2.
1513.3 Daylight Zone Control: All daylighted zones. as
defined in Chapter 2, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight- or occupant- sensing automatic controls,
which control the lights independent of general area lighting.
Contiguous daylight zones adjacent to vertical glazing are
allowed to be controlled by a single controlling device
provided that they do not include zones facing more than two
adjacent cardinal orientations (i.e. north, east, south, west).
Daylight zones under overhead glazing more than 15 feet
from the perimeter shall be controlled separately from daylight
zones adjacent to vertical glazing.
EXCEPTION: Daylight spaces enclosed by walls or
ceiling height partitions and containing 2 or fewer light
fixtures are not required to have a separate switch for
general area lighting.
1513.4 Display, Exhibition and Specialty Lighting
Controls: All display, exhibition or specialty lighting shall be
controlled independently of general area lighting.
1513.5 Automatic Shut -off Controls, Exterior: Lighting for
all exterior applications shall have automatic controls capable
of tuming off exterior lighting when sufficient daylight is
available or when the lighting is not required during nighttime
hours. Lighting not designated for dusk -to -dawn operation
shall be controlled by either:
a. A combination of a photosensor and a time switch;
or
b. An astronomical time switch.
Lighting designated for dusk -to -dawn operation shall be
controlled by an astronomical time switch or photosensor. All
time switches shall be capable of retaining programming and
the time setting during loss of power for a period of at least 10
hours.
EXCEPTION: Lighting for covered vehicle entrances
or exits from buildings or parking structures where
required for safety, security, or eye adaptation.
1513.6 Automatic Shut -Off Controls, Interior: Buildings
greater than 5,000 ft2 and all school classrooms shall be
equipped with separate automatic controls to shut off the
lighting during unoccupied hours. Within these buildings, all
office areas less than 300 ft2 enclosed by walls or ceiling -
height partitions, and all meeting and conference rooms, and
all school classrooms, shall be equipped with occupancy
sensors that comply with Section 1513.6.1. For other spaces,
automatic controls may be an occupancy sensor, time switch
or other device capable of automatically shutting off lighting.
EXCEPTIONS: 1. Areas that must be continuously
illuminated (e.g., 24 -hour convenience stores), or
illuminated in a manner requiring manual operation of
the lighting.
2. Emergency lighting systems.
3. Switching for industrial or manufacturing process
facilities as may be required for production.
4. Hospitals and laboratory spaces.
5. Areas in which medical or dental tasks are
performed are exempt from the occupancy sensor
requirement.
1513.6.1 Occupancy Sensors: Occupancy sensors shall
be capable of automatically turning off all the lights in an
area, no more than 30 minutes after the area has been
vacated.
Light fixtures controlled by occupancy sensors shall have a
wall- mounted, manual switch capable of turning off lights
when the space is occupied.
EXCEPTION: Occupancy sensors in stairwells are
allowed to have two step lighting (high -light and low -
light) provided the control fails in the high -light position.
1513.6.2 Automatic Time Switches: Automatic time
switches shall have a minimum 7 day clock and be capable
of being set for 7 different day types per week and
incorporate an automatic holiday "shut -off' feature, which
turns off all loads for at least 24 hours and then resumes
normally scheduled operations. Automatic time switches
shall also have program back -up capabilities, which prevent
the loss of program and time settings for at least 10 hours, if
power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a. is readily accessible;
b. is located so that a person using the device can see the
lights or the areas controlled by the switch, or so that the
area being illuminated is annunciated;
c. is manually operated;
d. allows the lighting to remain on for no more than 2 hours
when an over -ride is initiated; and
e. controls an area not exceeding 5,000 ft2 or 5% of the
building footprint for footprints over 100,000 ft2, whichever is
greater.
1513.7 Commissioning Requirements: For lighting
controls which include daylight or occupant sensing
automatic controls, automatic shut -off controls, occupancy
sensors, or automatic time switches, the lighting controls
shall be tested to ensure that control devices, components,
equipment and systems are calibrated, adjusted and operate
in accordance with approved plans and specifications.
Sequences of operation shall be functionally tested to
ensure they operate in accordance with approved plans and
specifications. A complete report of test procedures and
results shall be prepared and filed with the owner. Drawing
notes shall require commissioning in accordance with this
paragraph.
1514 Exit Signs: Exit signs shall have an input power
demand of 5 Watts or less per sign.
Motors - General Requirements
1511 Electric Motors: All permanently wired polyphase
motors of 1 hp or more, which are not part of an HVAC
system, shall comply with Section 1437.
EXCEPTIONS: 1. Motors that are an integral part of
specialized process equipment.
2. Where the motor is integral to a listed piece of
equipment for which no complying motor has been
approved.
Transformers - General Requirements
SECTION 1540 — TRANSFORMERS
The minimum efficiency of a low voltage dry-type
distribution transformer shall be the Class I Efficiency Levels
for distribution transformers specified in Table 4 -2 of the
"Guide for Determining Energy Efficiency for Distribution
Transformers" published by the National Electrical
Manufacturers Association (NEMA TP- 1- 2002).
PERMIT COORD COPY �
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -158 DATE: 02 -19 -08
PROJECT NAME: CLARKS
SITE ADDRESS: 466 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Buil �ng
urvision
Public Works
Fire Prevention
Structural
Planning Division
nPermit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete n
DUE DATE: 02-2 1 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
�
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03-20-08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routmg slip.doc
2 -28-02
Look Up a Contractor, Electrii or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
MKELEKE957PO
Licensee Name
M K ELECTRIC INC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
602543822
Ind. Ins. Account Id
10143400
Business Type
CORPORATION
Address 1
PO BOX 612
Address 2
City
BUCKLEY
County
PIERCE
State
WA
Zip
98321
Phone
3608295362
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
10/20/2005
Expiration Date
10/20/2009
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
OTIS *BC939L7
Electrical Administrator Information
License
OTIS *BC939L7
Name
OTIS, BRIAN C
Status
ACTIVE
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
FINNEY, MICHAEL F
AGENT
10/20/2005
FINNEY, MICHAEL F
PRESIDENT
10/20/2005
PEDERSEN, DOUGLAS
•
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MKELEKE957P0 06/10/2008
CODES
2006 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS
2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS
2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS
2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS
2006 WASHINGTON STATE ENERGY CODE
2005 NATIONAL ELECTRICAL CODE
BUILDING DEPARTMENT
CITY OF TUKWILA
DEPARTMENT OF COMMUNITY DEVELOPMENT
6300 SOUTHCENTER BLVD. #100
TUKWILA, WA 98188
PH. 206 -431 -3670
CODE INFORMATION
FULLY SPRINKLERED
CONSTRUCTION TYPE: 2B
OCCUPANCY CLASS: M
GROSS SQUARE FOOTAGE
NET SQUARE FOOTAGE
FRONT OF HOUSE AREA = 1,270 SF
(30 S.F./ OCCUPANT)
BACK OF HOUSE AREA = 1,243 SF
(300 S.F_ / OCCUPANT)
TOTAL OCCUPANT LOAD
NO. OF EMPLOYEES = 3 PERSONS
2,700 SF
2,521 SF
43
5
48
ENGINERING CONSULTANTS
MECHANICAL
POINT ONE DESIGN
9941 YORK THETA DRIVE
NORTH ROYALTON, OH 44133
PH. 440 -230 -1800
FX. 440 -230 -1831
ELECTRICAL
STADELMAN ASSOCIATES
931 PORTAGE TRAIL
CUYAHOGA FALLS, OH 44221
PH. 330- 926 -2600
FX. 330 - 926 -4531
DEVELOPER
WESTFIELD
11601 WILSHIRE BLVD.
14TH FLOOR
LOS ANGELES, CA 90025
CONTACT: JOSH KIMMEL
e -mail: JKIMMEL @WESTFIELD.COM
PH:310- 893 -4761
OWNER
CLARKS
156 OAK STREET
NEWTON UPPER FALLS, MA 02464
BOB JOHNSON
SENIOR DIRECTOR OF CONSTRUCTION
PH. (617) 796 -5056
FX. (617) 243 -4210
DENNIS HORN
DIRECTOR OF CONSTRUCTION
PH_ (617) 243 -4214
FX. (617) 243-4210
WESTFIELD SOUTHCENTER 466 SOUTHCENTER MALL TUKWILA, WA 98188
STORE # 753
KEY PLAN
i
L
110' "
fi
LEASELINE TO LEASELINE
Q
11' -3
GROSS LEASEABLE AREA
2,700 SQ. FT.
i
CLARKS
LEVEL 1 OF 3
SPACE #1010
51' -sin
VICINITY MAP
WESTFIELD SOUTHCENTER
466 SOUTHCENTER MALL SPACE #1010 TUKWILA, WA 98188
SOUTHCENTER
WESTFIELD
SOUTHCENTER
BAKER BLVD.
STRANDER BLVD.
LEASELINE TO LEASELINE
LOD PLAN
SCALE: 1/8"= f-0"
REVISION:
/ ' 02 -13 -08 -PER LANDLORD COMMENTS
-AKS
REVISIONS
No changes shall be made to the scope
of work of
Tukwila a B dinDivin
NOM Revisions require a new plan submittal
and may include additional plan review fees.
REVIEWED PL1ANCE
CODE CO
NFPA 70 -- NEC
City Of Tukwila ON
$ `'LOIN OM .
FILE COPY
Permit Nos
PJar review approval la too= and omissions.
Apvat of conelnictlei documents does wit aulhodze
the *Mon of any a dcodeor mamma, Ikseipt
of wood - _
BY
Date: d
City of Tukwila
BUILDING DIVISION
SEPARATE PERMIT
REQUIRED
MechanIcal
CI Electrical
OPiumbing
Gas Piping
City of Tukwila
BUILO%NQ DIVISION
'Rf't'h2gkitti I'i At!w V.1.414
I' I '�' `J= {� Oto, MODIFIED OR ALTERED
WITHOUT' AUTHORIZATION FROM THE BUILDING
qffIHIiki• t ALI WORK SHALL BE DONE IN
A@ OtiPkitt WITH THE APPROVE PLANS
I5 3,ti" -` tt to FIELD INSPECTIONS
ISSUE / DATE:
Public works, Building Division
PERMIT NUMBER
OS:i
INDEX OF DRAWINGS
ARCHITECTURAL
C100 COVER SHEET /INDEX/CODE INFO
C101 GENERAL NOTES
C102 FINISH SCHEDULE / RESPONSIBILITY SCHEDULE
C103 MOULDING SCHEDULE/ PROFILES
A100 FLOOR PLAN
A101 ENLARGED TOILET PLAN / ELEVATIONS
A102 EGRESS PLAN
A200 REFLECTED CEILING PLAN
A300 ENLARGED STOREFRONT PLAN/ ELEVATION
A400
INTERIOR ELEVATIONS
A401 INTERIOR ELEVATIONS
A500 STOREFRONT SECTIONS
A501 STOREFRONT DETAILS
A502 STOREFRONT DETAILS
A503 STOREFRONT DETAILS
A600
INTERIOR DETAILS
A700 DOOR SCHEDULE/ DETAILS/ NOTES
A701 THRESHOLDS & FLOORING TRANSITIONS
A800
A801
A802
A803
AS100
AS101
AS102
PLUMBING
FIXTURE PLAN
FIXTURES - DETAILS
FIXTURES - DETAILS
FIXTURES - DETAILS
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
P100 PARTIAL PLUMBING PLAN / DETAILS
P200 PLUMBING SPECIFCATIONS / SCHEDULE
MECHANICAL
M100
MECHANICAL PLAN
M200 MECHANICAL SYMBOLS, NOTES & SCHEDULES
ELECTRICAL
E100
E200
E300
LIGHTING PLAN
POWER PLAN
ELECTRICAL DETAILS
E400 ELECTRICAL SYMBOLS & NOTES/
LIGHTING FIXTURE SCHEDULE
E500 POWER RISER DIAGRAM / PANEL SCHEDULES
E600 ELECTRICAL SPECIFICATIONS
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
Cr— �a
FEB 1 2C38
& ASSOCIATES
> Retail Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666 -6767
AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334
FILE COPY
tG%
LEAVE TUG INCHES
FOR DRYWALL
INSTALLATION.
Hbff
e e
4 GANG BACKBOX.
COMMON FACEPLATE
nCn udu
e e
GIENSRAL DIBFLAY TRACK
LIGWTMG LIGWTe LIGk4T8
u &n
e
TRA.= TRACK MATURE
LIGHTS LIGWTS WALL
IIfII
6
MACK
LIGHTS J
e
e
FINISHED FLOOR
48"
1 MASTER SWITCHPLATE DETAIL
E100 SCALE NONE
GENERAL NOTES:
1. THE ELECTRICAL CONTRACTOR SHALL BE HELD TO HAVE REVIEWED ALL SHEETS OF THESE CONTRACT DOCUMENTS
INCLUDING ARCHITECTURAL, MECHANICAL, FIXTURE PLANS, ETC. & WILL BE RESPONSIBLE FOR PERFORMING ALL WORK
INDICATED ON ANY SHEET. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH
THE WORK OF OTHERS
2. REFER TO SHEE A200 FOR DIMENSIONED LOCATION OF LIGHT FIXTURES IN THE REFLECTED CEILING PLAN.
3. REFER TO SHEE ► E600. OR NOTES & SPECIFICATIONS.
4. REFER TO SHEE E400 OR LIGHTING SCHEDULE, FLAG NOTES, SYMBOL LEGEND & DETAILS.
5. REFER TO SHEE E500 OR RISER DIAGRAM & PANEL SCHEDULES.
6. NIGHT LIGHTING FIXTURES WITHOUT EMERGENCY FEATURE SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUITS AHEAD
OF ALL LOCAL SWITCHING. EC SHALL FURNISH AND INSTALL ADDITIONAL HOT WIRE IN BRANCH CIRCUIT TO ACCOMPLISH
THIS.
7. ALL WIRING LINES INCLUDING LOW VOLTAGE IN THE CEILING PLENUM SHALL BE IN CONDUIT.
8. EXISTING EXTERIOR LIGHTING TO REMAIN BY LANDLORD CONTROL.
NOTE: 2006 IBC — Sec. 1006
Provide an average of one
foot - candle illumination at the
floor along the entire egress
pathway and exit discharge
\,
i
FTCESJIEVVED FOR
4 :Pp 70 - NEC
t 10 2*
City Of Tukwila
INC DIVISION
CONNECTION TO
SIGN
T2 T4 T4 % T4 T4
LIGHTING PLAN
SCALE: 1 /4 " =1' -0"
"2\
FEB 1 9 Z003
& ASSOCIATES
> Retail Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666 -6767
AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
REVISION
A02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
LIGHTING PLAN
SHEET NO. :
E100
FIRE ALARM
JUNCTION 13OX
SUPPLIED BY LANDLORD
FURNISH AND INSTALL WIRING FOR POWER CIRCUIT.
FURNISH AND INSTALL WIRING FOR COMMUNICATION
CIRCUIT.
TO
ADDITIONAL
DEVICES
PROVIDE TIE IN AS
REQUIRED TO MALL
/ MAIN BUILDING FIRE
ALARM SYSTEM.
COORDINATE EXACT
REQUIREMENTS WITH
LANDLORD PRIOR
TO ROUGH N.
FIRE ALARM WIRING NOTES:
1. TENANT SHALL BE REQUIRED TO INSTALL AN ADDRESSABLE FIRE ALARM
SYSTEM PER LANDLORDS REQUIREMENTS. COORDINATE REQUIREMENTS
AND INSTALLERS WITH LANDLORD PRIOR TO N5TALLATION.
2. LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR 15 10 BE
DETERMINED.
3, tI-1I5 RISER REPRESENTS .4 TYPICAL SYSTEM AND 15 NoT INTENDED FOR
NSTALLATIOt( SYSTEM SUPPLIER 51-IALL PROVIDE INSTALLATION
DRAWINGS AND WIRING DIAGRAMS. EXACT SYSTEM REQUIREMENTS SHALL
IBE COORDINATED WITH tHE SYSTEM SUPPLIER
4. SYSTEM SUPPLIER SMALL SUPERVI5E INSTALLATION, PROGRAM AND TEST
SYSTEM, AND INSTRUCT OWNER ON SYSTEM OPERATION.
5_ ALL FIRE ALARM WIRING SHALL 13E IN 3/4" CONDUIT, MINIMUM. ALL WIRING
SHALL BE VERIFIED WITI -4 THE SYSTEM SUPPLIER PRIOR TO PIP.
6. PROVIDE ADDITIONAL ADDRESSABLE MONITOR AND CONTROL MODULES
AS RECOMMENDED BY tHE SYSTEM SUPPLIER
1. ALL CONTROL CABINET5 SHALL BE GROUNDED PER NEC. REQUIREMENTS
AND PER SPECIFICATIONS_
8. COORDINATE CITY TIE -IN REQUIREMENTS WITH LOCAL AUTHORITY.
REFER TO DRAWING5 FOR DEVICE QUANTITY AND LOCATIONS.
PROVIDE WIRING TO DEVICES
INDICATED AS REQUIRED BY FIRE
ALARM SYSTEM SUPPLIER
INSTALLATION DRAWINGS.
10. FIRE ALARM SYSTEM SHALL COMPLY WITH THE ZONING REQUIREMENTS OF
THE STATE BUILDING CODE AND THE NFPA. ALL INITIATING DEVICES
INDIVIDUALLY REPORT TO THE FIRE ALARM CONTROL PANEL FOR
SEPARATE ANNUNCIATION.
FIRE ALARM SYSTEM RISER DIAGRAM
NOT TO SCALE
TYPICAL WIRING NOTE_
FUR 4151-1 AND INSTALL WIRING TO ALL
SYSTEM DEVICES AS REQUIRED BY
SYSTEM INSTALLATION DRAWINGS.
REFER TO FIRE ALARM SYSTEM
NOTES.
30KVA XFMR
FLOOR MTD.)
FIRE ALARM
JUNCTION BOX
SUPPLIED BY
LANDLORD
MAIN 200A
DISCONNECT
SWITCH
PANEL HA
PANEL LA
TIM ECLOCK
GENERAL NOTES:
1. THE ELECTRICAL CONTRACTOR SHALL BE HELD TO HAVE REVIEWED ALL SHEETS OF THESE CONTRACT DOCUMENTS
INCLUDING ARCHITECTURAL, MECHANICAL, FIXTURE PLANS, ETC. & WILL BE RESPONSIBLE FOR PERFORMING ALL WORK
INDICATED ON ANY SHEET. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH
THE WORK OF OTHERS.
2. REFER TO SHEE
3. REFER TO SHEE
4. REFER TO SHEE
5. REFER TO SHEE
FOR DIMENSIONED LOCATION OF LIGHT FIXTURES IN THE REFLECTED CEILING PLAN.
FOR NOTES & SPECIFICATIONS.
FOR LIGHTING SCHEDULE, FLAG NOTES, SYMBOL LEGEND & DETAILS.
OR RISER DIAGRAM & PANEL SCHEDULES.
6. NIGHT LIGHTING FIXTURES WITHOUT EMERGENCY FEATURE SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUITS AHEAD
OF ALL LOCAL SWITCHING. EC SHALL FURNISH AND INSTALL ADDITIONAL HOT WIRE IN BRANCH CIRCUIT TO ACCOMPLISH
THIS.
7. ALL WIRING LINES INCLUDING LOW VOLTAGE IN THE CEILING PLENUM SHALL BE IN CONDUIT.
8. EXISTING EXTERIOR LIGHTING TO REMAIN BY LANDLORD CONTROL.
9. PHONE JACKS, PHONE CABLE AND DATA CABLE ARE PROVIDED BY THE ELECTRICAL CONTRACTOR
10. OUTLETS IN SALES AREA ONLY TO BE MOUNTED 26" A.F.F.
EMERGENCY CALL FOR AID AUDIOVISUAL DEVICE
MOUNTED OVER DOOR "CORNELL" VS -110
\
i
t
LA 21
CALL FOR AID POWER SUPPLY IEI 'PIP24VDC ABOVE
CEILING. REFER TO WIRING DIAGRAM ON TINS DRAWING.
I
I
LA 111
SPARE
I
NDTE :
UNIT EQUIPMENT SHALL BE
AS SUPPLIED BY "TRI -S
CONTROLS" (TOM
ANSPACI -1) 330 - 220 -4400
yD
EMERGENCY CALL FOR AID WIRING DIAGRAM
POWER PLAN
SCALE: 1/4"=11-0"
r r
FEB 19 [O>i3
F
STAD
` WAS o yid?':.
'pc, 38194 cc,
SS/O N AL Nc':;
1 EXPIRES cf 2.51`1 Ti
& ASSOCIATES
> Retail Design & Development
345 SPRINOSIDE DRIVE TEL 330 / 666 -6767
AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
REVISION :
02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
POWER PLAN
SHEET NO. :
E200
O
I�II�
ACCESS PANELS (TYP. 8)
O
O
1 CASHWRAP OUTLET PLAN
E300 SCALE: NONE
A - COUPONS, CUSTOMER SERVICE
FORMS, DESKTOP SUPPLIES
B - BINDERS, PHONE BOOKS,
ENVELOPES, BLANK PAPER
C - POSTAL & CLEANING SUPPLIES.
D - TAPE & STAPLER
E - COUPONS AND DAILY NOTES
TRANSACTION
COUNTER
UB_
E
CUB.
D
TILTED
MONITOR
RE'CP`Ij
PTR.
KEYBOARD
SC
USE
PHO
NE
E
PLAN
BOOT BAG
O r-D
SML BAG
CASH DWR
B
?RTR
CPU
CABLE
ELEVATION
2 DETAIL- CASHWRAP POS LAYOUT
E300 SCALE: 3/4" = 1'
FURNISH AND INSTALL PHOTOELECTRIC DUCT
MOUNTED SMOKE DETECTOR WITH AUXILIARY
CONTACTS. WIRE TO SHUT DOWN FP5 UNIT UPON
ACTIVATION. COORDINATE EXACT MOUNTING
LOCATION WITH MC AND AUTHORITY HAVING
JURISDICTION ON SITE.
"FCI *DH100ACDCP PI- IOTOELECTRIC TYPE 4 -WIRE.
LA
C/B LOCK ON CLIP
1*15 AWG IN 1"C
FURNISH AND INSTALL. SAMPLING
TUBE. LENGTH TO BE SPECIFIED BY
TI-IE MC_
RETURN 4 SUPPLY DUCTS
CO n--- FURNISH AND INSTALL:
FCI* SSK451 REMOTE TEST STATION WITW POWER
ALARM AND TROUBLE LIGHT AND A BUZZER WHERE
REQUIRED BY LOCAL AUTHORITY, ADD FCI *P524L0
FIRE STROBE LIGHT. DUAL GANG MOUNTED, 1 PLATE.
I IC FURNISHED ,411../ 1 1 W 1!"14_ 41../ THERMOSTAT
TYPICAL DUCT MOUNTED SMOKE DETECTOR
4 ALARM INDICATION WIRING DIAGRAM
E300 SCALE: NONE
NOTE:
UNIT EQUIPMENT SHALL BE AS SUPPLIED BY "TRI -S
CONTROLS" (GEORGE JARMUSIK) 330 - 220 -4400
OUTLET FOR
r
15ACKROOM PHONE
MAIN TELEPHONE
NUMBER
Ow-
RJ11C
2'x4' PLYWOOD
PHONE BOARD
MOUNTED TO WALL IN
BACKROOM
/11
1
J
3 PAIR PHONE CABLE
N CONDUIT TO
CASHWRAP
CAT. 5 CABLE TO
CASHWRAP
SPARE TWISTED PAIR
SECOND TELEPHONE
NUMBER
TELEPHONE
COMPANY PUNCH
DOWN BLOCK
ROM TELEPHONE
COMPANY
3 TELEPHONE / ADT RISER DIAGRAM
E300 SCALE: NONE
'! A
FEB 19 2003
L,1\ i Lza
1IJNI1NUI avi'1
& ASSOCIATES
> Retail. Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666 -6767
AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
REVISION :
02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
ELECTRICAL
DETAILS
SHEET NO. :
E300
ACCESS PANELS (TYP. 8)
O
O
1 CASHWRAP OUTLET PLAN
E300 SCALE: NONE
A - COUPONS, CUSTOMER SERVICE
FORMS, DESKTOP SUPPLIES
B - BINDERS, PHONE BOOKS,
ENVELOPES, BLANK PAPER
C - POSTAL & CLEANING SUPPLIES.
D - TAPE & STAPLER
E - COUPONS AND DAILY NOTES
TRANSACTION
COUNTER
UB_
E
CUB.
D
TILTED
MONITOR
RE'CP`Ij
PTR.
KEYBOARD
SC
USE
PHO
NE
E
PLAN
BOOT BAG
O r-D
SML BAG
CASH DWR
B
?RTR
CPU
CABLE
ELEVATION
2 DETAIL- CASHWRAP POS LAYOUT
E300 SCALE: 3/4" = 1'
FURNISH AND INSTALL PHOTOELECTRIC DUCT
MOUNTED SMOKE DETECTOR WITH AUXILIARY
CONTACTS. WIRE TO SHUT DOWN FP5 UNIT UPON
ACTIVATION. COORDINATE EXACT MOUNTING
LOCATION WITH MC AND AUTHORITY HAVING
JURISDICTION ON SITE.
"FCI *DH100ACDCP PI- IOTOELECTRIC TYPE 4 -WIRE.
LA
C/B LOCK ON CLIP
1*15 AWG IN 1"C
FURNISH AND INSTALL. SAMPLING
TUBE. LENGTH TO BE SPECIFIED BY
TI-IE MC_
RETURN 4 SUPPLY DUCTS
CO n--- FURNISH AND INSTALL:
FCI* SSK451 REMOTE TEST STATION WITW POWER
ALARM AND TROUBLE LIGHT AND A BUZZER WHERE
REQUIRED BY LOCAL AUTHORITY, ADD FCI *P524L0
FIRE STROBE LIGHT. DUAL GANG MOUNTED, 1 PLATE.
I IC FURNISHED ,411../ 1 1 W 1!"14_ 41../ THERMOSTAT
TYPICAL DUCT MOUNTED SMOKE DETECTOR
4 ALARM INDICATION WIRING DIAGRAM
E300 SCALE: NONE
NOTE:
UNIT EQUIPMENT SHALL BE AS SUPPLIED BY "TRI -S
CONTROLS" (GEORGE JARMUSIK) 330 - 220 -4400
OUTLET FOR
r
15ACKROOM PHONE
MAIN TELEPHONE
NUMBER
Ow-
RJ11C
2'x4' PLYWOOD
PHONE BOARD
MOUNTED TO WALL IN
BACKROOM
/11
1
J
3 PAIR PHONE CABLE
N CONDUIT TO
CASHWRAP
CAT. 5 CABLE TO
CASHWRAP
SPARE TWISTED PAIR
SECOND TELEPHONE
NUMBER
TELEPHONE
COMPANY PUNCH
DOWN BLOCK
ROM TELEPHONE
COMPANY
3 TELEPHONE / ADT RISER DIAGRAM
E300 SCALE: NONE
'! A
FEB 19 2003
L,1\ i Lza
1IJNI1NUI avi'1
& ASSOCIATES
> Retail. Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666 -6767
AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
REVISION :
02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
ELECTRICAL
DETAILS
SHEET NO. :
E300
FLAG NOTES
SAW CUT AND REPAIR FLOOR FOR CONDUIT INSTALLATION. EXERCISE EXTREME
CARE AND CAUTION. IF LEASED SPACE IS NOT SLAB ON GRADE THEN SLAB MUST
BE CORE DRILLED IN ACCORDANCE WITH LANDLORD REQUIREMENTS. ALL CUTTING
MUST BE APPROVED BY LANDLORD'S REPRESENTATIVE PRIOR TO ROUGH IN.
RECEPTACLE OUTLET SHALL BE INSTALLED DIRECTLY ABOVE SHOW WINDOW FOR
EACH 12 FT OR MAJOR FRACTION THEREOF OF SHOW WINDOW AREA MEASURED
HORIZONTALLY AT ITS MAXIMUM WIDTH.
3/4" CONDUIT BACK TO PHONE BOARD FOR TELEPHONE CABLING. FURNISH AND
INSTALL PULLWIRE.
MOUNT RECEPTACLES, TELEPHONE JACKS & SPEAKER WIRES IN CASH WRAP
MILLWORK BELOW COUNTER. REFER TO CASHWRAP DETAILS & NOTES. ALL WIRING
TO "TTB" SHALL BE IN CONDUIT.
3/4" CONDUIT BACK TO PHONE BOARD FOR DATA CABLING. FURNISH AND INSTALL
PULLWIRE.
EMERGENCY FIXTURES WHICH ARE NOT INDICATED AS NIGHT LIGHTS SHALL BE
SWITCHED AS INDICATED. BATTERY TO BE WIRED HOT AHEAD OF SWITCH AS
REQUIRED BY MFGR. FURNISH AND INSTALL ADDITIONAL HOT WIRE AS REQUIRED.
DOOR BELL SYSTEM. REFER TO ELECTRICAL SYMBOL LEGEND.
"TTB" (TELEPHONE TERMINAL BOARD)- FURNISH AND INSTALL PLYWOOD BACKBOARD
3/4 "X2'X4' MOUNTED AT 6' -O" AFF TO CENTERLINE. FURNISH AND INSTALL #8
AWG CU TO SERVICE ENTRANCE GROUND TERMINATED ON GROUND BAR LOCATED
AT BOTTOM OF "TTB "_
PROVIDE A 4 "x4 "x2 1/8" OUTLET BOX ON TTB FOR TERMINATION OF TELEPHONE
WIRING FROM CASH WRAP.
INSTA HOT UNIT UNDER SINK, 4.6KW, 208V-lph FURNISHED AND INSTALLED BY
OTHERS, WIRED BY EC. FURNISH AND INSTALL DISCONNECT SWITCH IF REQUIRED
BY EQUIPMENT LITERATURE.
EC TO PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANTS
TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZINGTHE LANDLORD
SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE
CAULKED AS REQUIRED.
TENANT SOUND SYSTEM TO BE INSTALLED BY MUZAK. G.C. TO COORDINATE
WIRE TO LOCAL LIGHTING CIRCUIT AHEAD OF ALL LOCAL SWITCHING.
WIRE THROUGH SWITCH AS REPRESENTED IN THE "MASTER SWITCHPLATE" WITH
CORRESPONDING LOWER CASE LETTER.
WIRE THROUGH TIME CLOCK AND LIGHTING CONTACTOR LOCATED IN BACK ROOM.
REFER TO POWER RISER DIAGRAM
HVAC UNIT DUCT SMOKE DETECTOR SHALL SHUT DOWN HVAC UNIT (COORDINATE
LOCATION AND WIRING WITH HVAC CONTRACTOR).
LOCATION OF MASTER SWITCHPLATE.
CONNECTION TO SIGN OVER DOOR. COORDINATE EXACT WIRING REQUIREMENTS
WITH SIGN MANUFACTURER PRIOR TO ROUGH IN.
CONNECTION TO "FEATURE WALL" SHALL BE COORDINATED ON SITE WITH
MANUFACTURER. FEATURE WALL CONSISTS OF T8 LAMPS ARRANGED AS REQUIRED
BY MANUFACTURER. TOTAL FIXTURE WATTAGE ASSUMED TO BE NOT OVER 300
WATTS.
TIME DELAY SWITCH FOR CONTROL OF RESTROOM LIGHT AND EXHAUST FAN,
GREENHECK "GTD" TIME DELAY SWITCH, OR APPROVED EQUAL. EC SHALL SET TIME
DELAY FOR FIVE MINUTES.
NOTE:
N/A = NOT APPLICABLE TO THIS PROJECT.
LIGHTING SCHEDULE
SYMBOL LEGEND
TYPE
DESCRIPTION
CATALOG #
LAMP
FIXTURE LOCATION /NOTES
IUTAL
WATTS
QTY.
0��
♦s!
A
LUMASTAR EB SERIES 16" ZENOS DIRECT /INDIRECT
ACRYLIC LUMINAIRE ELECTRONIC BALLAST, CLEAR
ACRYLIC.
EB- A -Z -C-
70ED17-
24WHT
70 (ED17)
120 VOLT
MOUNTED IN SALES AREA :
IF 11' -0" CEILING -TO BE CEILING
MOUNTED. IF 12' -0" - 13' -O" CEILING
MOUNT AT 10' -0" TO BOTTOM OF
FIXTURE
70
2
0
B
7" ADJUSTABLE INCANDESCENT PAR 38 RECESSED
DOWNLIGHT WITH CLEAR ALZA RELECTOR
SPA7X -PAR38
- 25- 45 -TBC-
AR7500CL
CDM -125w/
830/PAR38/10
SPOT
MOUNTS RECESSED IN ACT. CLG.
TILES IN MAIN SALES AREA.
PROVIDE HANG BARS AND CLIPS
25
BE
LIGHTOLIER CALCULITE COMPACT FLUORESCENT
OPEN RECESSED DOWNLIGHT WITH CLEAR
IRIDESCENCE FREE REFLECTOR TRIM, WHITE FLANGE.
8" APERTURE (2) TRIPLE TUBE HORIZONTAL LAMP,
BATTERY BACK UP AND TEST SWITCH
8038 -CLW-
8242HU-
FA EM4E
(2) 26W TRIPLE
TUBE
MOUNTS RECESSED IN ACT. CLG. TILES IN
MAIN SALES AREA. PROVIDE HANG BARS
AND CLIPS- WIRED AS EMERGENCY LIGHT
FIXTURE
54
SDOOR B
6
e C
LIGHTOLIER LYTECASTER RECESSED DOWNLIGHTING. 5"
APERATURE RECESSED ADJUSTABLE REFLECTOR TRIM - WHITE
1029WH
75W
PAR30
MOUNTS RECESSED IN MAIN SALES
AREA AROUND CASH WRAP
75
0
JUNO MULTI -SPOT RECESSED ADJUSTABLES WHITE
CLOSED -PAN TRIM APPEARANCE. 45 DEGREE AIMING 360
DEGREE ROTATION AND HANGER BARS
MS303-
70- EMH -WH,
HB26
(3) CDM70
PAR3OL/FL
MOUNTS RECESSED IN GYP. BD.
SOFFIT AT DISPLAY WINDOWS
210
0
O O O
D1
la F
JUNO MULTI -SPOT RECESSED ADJUSTABLES WHITE
CLOSED -PAN TRIM APPEARANCE. 45 DEGREE AIMING 360
DEGREE ROTATION AND HANGER BARS
MS302-
39- EMH -WH
HB26
(2) 39W-
MHPAR3OUFL
MOUNTS RECESSED IN GYP. BD. SOFFIT
AT DISPLAY WINDOWS
88
4
0.0
D2
0
E
TECH LIGHTING EMERGE PENDANT - COLOR:TAHOE PINE
AMBER
TT -A
(1) 120 VOLT, 75
WATT MEDIUM
BASE -A 19
SUSPENDED IN SALES AREA IN
OVER CASH WRAP @ T -0" TO
BOTTOM OF FIXTURE
75
4
DD F
MERCURY LIGHTING PRODUCTS SURFACE MOUNTED MULTI
LAMP FLUORESCENT CHANNELS. 2 LAMP 4'
MM- 2- 32 -OCT/
4T- C- ELB -120V
(2) F32T8/
TL830 /ALTO
SURFACE MOUNTS TO
ACOUSTIC TILE CEILING IN
BACK ROOM
65
UNO U
F
N.L. N
COLUMBIA SURFACE MOUNT 2 -LAMP 4' PROFILE
WRAPAROUND - WHITE FINISH WITH PRISMATIC ACRYLIC
DIFFUSER
AWN4 -240
EB8- 120 -EL
(2) F32T8/
TL830 /ALTO
SURFACE MOUNTS TO GYP.
BD. CEILING IN TOILET ROOM.
65
1
G
&
TH
LIGHTOLIER LYTESPAN TRACK LIGHTING SYSTEM
22SS8BK
ALCYON ENCLOSED STEP SPOT PAR38
22SS8BK
CDM -i25w/
830/PAR38/10
SPOT
SURFACE MOUNTED IN
SALES AREA
25
80
LIGHTOLIER BASIC LYTESPAN 1 CIRCUIT TRACK 6000
SERIES BLACK
(2', 4', AND 8' TRACK)
6000BK (2')
6001 BK (4')
6002BK (8')
BLACK
1 CIRCUIT
120V
SURFACE MOUNTED IN SALES AREA.
-
2' = 4
4' - 10
T#
COOPER LIGHTING SURE -LITES SURFACE MOUNTED
SELF - POWERED EMERGENCY LIGHTING UNIT
CC2
INCANDESCENT
SURFACE MOUNTED IN BACK ROOM
WALL, 12" BELOW FINISH CEILING.
18
5
EM
x ®
6
X1 X1
•
LIGHTALARMS, SERIES SIMPLICITY, UNIVERSAL RECESSED
MOUNT, SELF POWERED LED EDGE -LIT EXIT SIGN
SLEDWGCD
LED
RECESS WALL /CEILING MOUNT IN SALES
AREA- MOUNT 12" ABOVE DOOR JAMB FOR
WALL MOUNTED CONDITIONS
3
1
0
X2 X2
SURFACE WALL / CEILING MOUNTED SINGLE OR DUAL FACE
EXIT LIGHT WITH TEST SWITCH AND POWER INDICATOR LIGHT.
BP- PLED -5G
LED
SURFACE MOUNT TO WALUCEILING IN
BACK ROOM- MOUNT 12" ABOVE DOOR
HEAD FOR WALL MOUNTED CONDITIONS
5
3
LIGHTING SCHEDULE NOTES
1. ELECTRICAL CONTRACTOR SHALL VERIFY QUANTITIES OF FIXTURES & LAMPS ON LIGHTING & POWER PLAN.
2. ALL FIXTURES SHALL BE FURNISHED BY OWNER, INSTALLED & WIRED BY CONTRACTOR
3. ALL SPEAKER COVERS, CLEANOUTS, PLATES, ETC. IN SALES AREA SHALL BE FINISHED TO MATCH ADJACENT SURFACES UNLESS OTHERWISE NOTED.
4. SOFFIT DIMENSIONS ARE FINISH TO FINISH.
5. INTERIOR FINISHES ON WALLS AND CEILING SHALL BE CLASS B AT A MINIMUM
6. COMBUSTIBLE MATERIAL IS NOT TO BE USED IN AREAS IN WHICH PLENUM RETURN AIR SYSTEMS ARE USED.
7. FIXTURE SHALL BE PRE -WIRED FROM THE FACTORY FOR SWITCHED OPERATION.
EMERGENCY BATTERY PACK SHALL OPERATE IN EMERGENCY MODE ONLY.
8. LIGHTING SUPPLIER TO VERIFY LIGHT QUANTITIES AGAINST ARCHITECTS COUNTS
SYMBOL
DESCRIPTION
NEUT.
HOT
EQUIP. GROUND HOMERUN TO PANEL "LA" INDICATING CIRCUIT NUMBERS - ALL WIRING SHALL BE
3 #12 WITH GROUND WIRE UON (INCREASE TO #10 FOR CIRCUITS BETWEEN 100
1 AND 200 LF) CONSULT ENGINEER FOR RUNS OVER 200 LIN FEET IF WIRE SIZE IS
NOT INDICATED - ALL HOMERUNS SHALL BE TO A 20 AMPERE, 1 POLE CIRCUIT
LA BREAKER UON. WHERE WIRE FILL IS NOT SHOWN, FURNISH AND INSTALL 2 #12,
1#12G, 3/4 "C
It
$ M
SWITCH, SINGLE POLE, 20A, 120/277V
,3 S
SWITCH, THREE -WAY, 20A, 120/277V
MOUNTING - 48" A.F.F., CATALOG NO. HUBBELL, 1223 SERIES.
M S
SPST, 20A, MANUAL MOTOR STARTER, HP RATED WITH THERMAL OVERLOAD
MOUNTING - AS REQUIRED.
0 J
JUNCTION BOX, MOUNTING HEIGHT AND SIZE AS REQUIRED
OR AS NOTED ON PLANS.
Q D
DUPLEX RECEPTACLE, GROUNDING TYPE, 20A, 125V, 3 WIRE, NEMA 6 -20R
MOUNTING - 15" A.F.F. (26" A.F.F. IN SALES). CATALOG NO. HUBBELL 5262 SERIES (UNO).
(174) D
DOUBLE DUPLEX RECEPTACLE, GROUNDING TYPE, 20A, 125V, 3 WIRE, NEMA 6 -20R
MOUNTING - AS NOTED ON PLANS, CATALOG NO. HUBBELL, 2 -5262 SERIES.
DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20A, 125V, 3 WIRE, NEMA
6 -20R MOUNTING - PER DETAIL, CATALOG NO. HUBBELL GF -5262 SERIES.
p C
CLOCK HANGER TYPE RECEPTACKLE BY PASS & SEYMOUR #S3713 -W OR EQUAL. MOUT AT 6' -0"
AFF
V D
DESK PHONE OUTLET. MOUNTING - 18" AFF
V P
DESK DATA OUTLET. MOUNTING - 18" AFF. MAY BE IN THE SAME OUTLET BOX AS THE
ELECTRICAL PANEL - IDENTIFICATION NUMBER AS NOTED. REFER TO
DISTRIBUTION DIAGRAM AND PANEL SCHEDULE. MOUNTING - TOP 6 -0" A.F.F.
® E
Ell (
DISCONNECT SWITCH: HEAVY DUTY, NEMA 1 UNLESS NOTED AS "WP" FOR WEATHERPROOF
SDOOR B
BELL - 24V, AC VIBRATING TYPE, MOUNTING - 7'-0" A.F.F,
CATALOG NO. EDWARDS 340 -4G5.
DOOR BELL PUSH BUTTON MOUNTING - 48" A.F.F., CATALOG NO. EDWARDS 852.
• D
SIGNAL TRANSFORMER, 20VA, 120V PRIMARY, 24V SECONDARY
MOUNTING - ABOVE CEILING UNO, CATALOG NO. EDWARDS 592.
III
FIRE ALARM PULL STATION MOUNTED AT 48" AFF UON
la F
L F
FIRE ALARM HORN WITH STROBE LIGHT - WALL MOUNTED AT 80" AFF UON
W
FIRE ALARM STROBE LIGHT - WALL MOUNTED AT 80" AFF UON
F
L F
/s F
FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED
DD F
FIRE ALARM DUCT SMOKE DETECTOR - WITH REMOTE TEST STATION - COORDINATE
DUCT MOUNTING WITH THE MC
Ho F
FIRE ALARM RATE OF RISE HEAT DETECTOR - CEILING MOUNTED
WP W
REVITCv D O
UNO U
UNLESS NOTED mtkR Z) ZI;a
N.L. N
NIGHT LIGHT Of TukV�.11�a
Cl .- .. -r"h.I
TTB T
TELEPHONE TERMINAL BOARD
B' LOIN .- Iv : 7
Cir'
FEB 19 ZOG3
FEoa.,js i aR
IA
& ASSOCIATES
> Retail Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666 -6767
AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
REVISION :
A02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
ELECTRICAL
SYMBOLS / NOTES /
DETAILS / LIGHTING
SCHEDULE
SHEET NO. :
E400
EXISTING 200A DISCONNECT SWITCH
FURNISHED AND INSTALLED BY
LANDLORD.
EC SHALL FURNISH AN IDENTIFICATION
NAMEPLATE ON TENANT'S DISCONNECT
SWITCH IN LANDLORD'S SWITCHBOARD.
NAMEPLATE SHALL BE 1/8" THICK
PLASTIC, BLACK ON WHITE AND ETCHED
LETTERS. THE MINIMUM SIZE SHALL BE
ONE INCH (1") WITH ONLY THE
TENANT'S SPACE NUMBER ENGRAVED ON
SUCH, PERMANENTLY AFFIXED
NDLORD PROVIDED
METERING EQUIPMENT
LANDLORD SPACE
LANDLORD'S
EXISTING
ELECTRICAL
DISTRIBUTION
EQUIPMENT TO
REMAIN
I
200A
EXISTING TO REMAIN 4 #3/0, 1#6G, IN
LANDLORD - PROVIDED 3 "C.
V
PANEL NAME: HA
LOAD SUMMARY
PHASE BREAKDOWN
LEGEND
MOUNTING: SURFACE
LOAD
KWC
AMPS
D.F.
KWD
AMPS
TOTAL PANEL
LTG = LIGHTING
VOLTAGE: 480/277V- 3ph-4W
LTG
6.88
1.25
8.60
KWC PHASE A:
9.73
REC = RECEPTACLES
BUS RATING: 225A
REC
4.02
N.E.C.
4.02
KWC PHASE B.
7.48
AC = AIR CONDITIONING
MAIN: 200A MAIN CIRCUIT BREAKER
AC
9.03
1.00
9.03
KWC PHASE C:
9.08
W. HTR = WATER HEATER
A.I.C. 14,000 AIC
W. HTR.
4.16
1.00
4.16
MISC. = MISCELLANEOUS
ETR OR NEW: NEW
MISC.
2.20
1.00
2 -20
D.F. = DEMAND FACTOR
PANEL NOTES:
TOTAL
26.29
32
28.01
34
I
N.E.C. = NATIONAL ELECT- CODE
MINIMUM SERVICE SIZE 34
CCT
NOTES
DESCRIPTION
LTG
REC
AC
W.HTR.
MISC
C/B
PHASE
CB
DESCRIPTION
LTG
REC
AC
W.HTR.
MISC
NOTES
CCT
1
FPB-1 (HEATER)
2-66
0.90
20/3 HACR
A
60/3
PANEL LA
1.82
0.72
0.00
2.08
1.40
A
2
3
2
DUCT SMOKE DETECTOR
2.66
B
2.27
2.10
0.00
0.00
0.45
4
5
B
4
2.66
BACKROOM LIGHTING / EF
C
2.79
1.20
0.00
2.08
0.35
C
6
7
0.63
FPB -1 (FAN)
1-05
C
_
20/1
A
TTB
SPACE
0.20
20 /1
A
8
9
0.57
SPACE
D
8
9
B
FRAME RELAY AND ALARM
SPACE
0.40
20/1
B
10
11
0.57
SPACE
E
10
11
C
CASH WRAP
SPACE
0.30
20/1
C
12
13
0.63
SPACE
F
12
13
A
CASH WRAP
SPACE
0.30
20/1
A
14
15
0.30
SPACE
G
14
B
SPACE
16
17
SPACE
15
C
DESK
SPACE
0.36
20/1
B
18
19
1.23
SPACE
1
16
17
A
SPACE
2.08
C
20
21
0.35
SPACE
1
18
B
INSTA HOT
SPACE
30/2
22
23
SPACE
19
C
SPACE
2 -08
A
20/1
SALES AREA RECEPTACLES
24
25
SPACE
20
21
SHOW WINDOW RECEPTACLES
A
1.20
SPACE
20/1
B
20/1
BACKROOM RECEPTACLES
26
27
SPACE
22
23
SHOW WINDOW RECEPTACLES
B
1.20
SPACE
20/1
C
20/1
SPARE
28
29
SPACE
24
25
BACKROOM RECEPTACLES
C
0 -18
SPACE
20/1
A
2011
SPARE
30
TOTALS:
0.00
0.00
9.03
0.00
0.00
BACKROOM RECEPTACLES
0.36
6.88
4.02
0.00
4.16
2.20
TOTALS:
PANEL NAME: LA
LOAD SUMMARY
PHASE BREAKDOWN
LEGEND
MOUNTING: SURFACE
LOAD
KWC
AMPS
D.F.
KWD
AMPS
TOTAL PANEL
LTG = LIGHTING
VOLTAGE: 208Y /120V- 3ph-4W
LTG
6 -88
t25
8.60
KWC PHASE A:
6 -02
REC = RECEPTACLES
BUS RATING: 100A
REC
4.02
N.E.C.
4.02
KWC PHASE B:
4.82
AC = AIR CONDITIONING
MAIN: 100 A MAIN CIRCUIT BREAKER
AC
0.00
1.00
(100
KWC PHASE C:
6.42
W. HTR = WATER HEATER
AI_C. 10,000
W. HTR.
4.16
1.00
4.16
MISC. = MISCELLANEOUS
ETR OR NEW: NEW
MISC.
2.20
1.00
2.20
D.F. = DEMAND FACTOR
PANEL NOTES:
TOTAL
17.26
47 -94
18.98
52 -72
N.E.C. = NATIONAL ELECT. CODE
MINIMUM SERVICE SIZE
CCT
NOTES
DESCRIPTION
LTG
REC
AC
W.HTR.
MISC
C/B
PHASE
C/B
DESCRIPTION
LTG
REC
AC
W.HTR.
MISC
NOTES
CCT
1
ELECTRIC WATER COOLER
0.90
20/1
A
20/1
GENERAL AND EMERGENCY
0 -95
A
2
3
2
DUCT SMOKE DETECTOR
0 -05
20/1
B
20/1
DISPLAY LIGHTING
0.47
B
4
5
BACKROOM LIGHTING / EF
1 -18
0.05
20/1
C
20/1
TRACK LIGHTING
0.63
C
6
7
2
TTB
0.20
20 /1
A
20/1
TRACK LIGHTING
0.57
D
8
9
2
FRAME RELAY AND ALARM
0.40
20/1
B
20/1
TRACK LIGHTING
0.57
E
10
11
CASH WRAP
0.30
20/1
C
20/1
TRACK LIGHTING
0.63
F
12
13
CASH WRAP
0.30
20/1
A
20/1
FEATURE WALLS
0.30
G
14
15
DESK
0.36
20/1
B
20/1
SIGN
1.23
1
16
17
2.08
C
20/1
SHOW WINDOW LIGHTING
0.35
1
18
INSTA HOT
30/2
19
2 -08
A
20/1
SALES AREA RECEPTACLES
0.54
20
21
SHOW WINDOW RECEPTACLES
1.20
20/1
B
20/1
BACKROOM RECEPTACLES
0.18
22
23
SHOW WINDOW RECEPTACLES
1.20
20/1
C
20/1
SPARE
24
25
BACKROOM RECEPTACLES
0 -18
20/1
A
2011
SPARE
26
27
BACKROOM RECEPTACLES
0.36
20/1
B
20/1
SPARE
28
29
SPARE
20 /1
C
20/1
SPARE
30
TOTALS:
1.18
3 -30
0 -00
4-16
2 -20
5.70
0.72
0.00
0.00
0 -00
TOTALS:
TENANT SPACE
EC SHALL RELOCATE
EXISTING 200A
FUSED DISCONNECT
SWITCH.
1
200A
NEW 4 #3 /O, 1#6G, 3 "C
BY EC.
NEW 3 #12, 1#12G,
3/4 "C BY EC.
FPB -1
480V /3PH
8KW HEATER
277V/1PH
1 /2HP FAN MOTOR
3.8FLA
P
NEW 4 #3 /O, 1#6G,
3 "C BY EC.
NEW JUNCTION BOX BY
EC
200A
MCB
20/3
20/1
60/3
eTh
NEW PANEL 'HA'
480/277V, 3P H
(BY EC)
'I POWER RISER DIAGRAM
A500 SCALE: NONE
PANEL SCHEDULE NOTES:
1. ROUTE POWER THROUGH TIME CLOCK
2.
CIRCUIT BREAKER SHALL HAVE LOCK ON
CIRCUIT BREAKER CLIP.
A,B,C,D, ETC = SWITCHES AS INDICATED ON
LIGHTING FLOOR PLAN.
TIMER NOTE:
SET TIMER FOR STOREFRONT
SIGNAGE AND LIGHTING PER
THE MALL'S OPERATING HOURS
120V - CONTROL
•--II •
NEUTRAL
LOAD
LOAD
r
NEW 2 #12, 1#12G,
3/4 "C BY EC.
480V
PRIMARY
NEW 3 #6,
1#10G, 3/4 "C
BY EC
NEW 30KVA XFMR
(FLOOR MTD.)
BY EC
- NEW 4 #3, 1#8G,
1-1/4"C BY EC.
208Y/120V
SECONDARY
NEW BY EC #6 AWG CONTINUOUS
COPPER GROUNDING CONDUCTOR
AND BOND TO THE NEAREST OF
EITHER EFFECTIVELY - GROUNDED
BUILDING STEEL OR COLD WATER
PIPE WITHIN 5' -O" FROM POINT OF
ENTRANCE INTO THE BUILDING TO
REMAIN.
TIME CLOCK:
120V CONTROL,
40 AMP CONTACTS,
NEMA 1 ENCLOSURE,
24HR: SAME ON /OFF TIME EACH DAY,
WITH RESERVE POWER.
FURNISH AND INSTALL THE FOLLOWING TIME
CLOCK DEPENDING ON THE NEED DEPICTED;
TORK # W300L: UP TO 3 CIRCUITS
100A
MCB
NEW PANEL 'LA'
208/120V, 3PH
(BY EC)
_. REVI.E\N ED FOR
CODE COMPLIANCE EC
NFPA
Oty Of Tuoila
FEB 19 2013
w
0
x
w
& ASSOCIATES
> Retail Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666-6767
AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01 -30 -2008
REVISION :
02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
PANEL SCHEDULE
/ POWER RISER
DIAGRAM
SHEET NO. :
E500
ExPri�ES t� v
SECTION 16010 - ELECTRICAL GENERAL PROVISIONS
1. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS,
SUPPLEMENTARY CONDITIONS, ALTERNATES, ADDENDAS AND DIVISION 1 ARE A PART
OF THIS SPECIFICATION. ELECTRICAL, ARCHITECTURAL, MECHANICAL AND ALL
OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS ARE A
PART OF THE CONTRACT DOCUMENTS.
2. VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH THE CONDITIONS
AFFECTING THE INSTALLATION. SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE
KNOWLEDGE OF SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE
ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF
IGNORANCE OF THESE CONDITIONS.
3. DEFINITIONS:
A. "CONTRACTOR" AS USED WITHIN THE CONTEXT OF THE ELECTRICAL CONTRACT
DOCUMENTS SHALL EXPLICITLY REFER TO THE "ELECTRICAL CONTRACTOR ".
B. THE TERM "FURNISH" SHALL MEAN TO SUPPLY AND DELIVERY TO THE PROJECT
SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND
SIMILAR OPERATIONS.
C. THE TERM "INSTALL" SHALL MEAN WORK WHICH INCLUDES THE ACTUAL
UNLOADING, UNPACKING, ASSEMBLY, ERECTING, PLACING, ANCHORING,
APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING,
CLEANING, AND SIMILAR OPERATIONS.
D. THE TERM "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL, COMPLETE AND
READY FOR THE INTENDED USE.
4. INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES AND PERMITS NECESSARY
FOR THE PROPER COMPLETION OF ALL ELECTRICAL WORK SHOWN. ITEMS OMITTED,
BUT NECESSARY, TO MAKE THE ELECTRICAL SYSTEM COMPLETE AND WORKABLE
SHALL BE UNDERSTOOD TO FORM PART OF THE WORK.
5. IT IS THE PURPOSE OF THE ELECTRICAL DRAWINGS TO INDICATE THE APPROXIMATE
LOCATION OF ALL EQUIPMENT, OUTLETS, ETC. ASCERTAIN EXACT LOCATIONS AND
ARRANGE WORK ACCORDINGLY. THE RIGHT IS RESERVED TO EFFECT REASONABLE
CHANGES IN THE LOCATION OF OUTLETS UP TO THE TIME OF ROUGHING -IN, WITHOUT
ADDITIONAL COST TO THE OWNER.
6. TEMPERATURE AND INTERLOCK CONTROLS ARE PROVIDED AND WIRED BY
A CONTROLS CONTRACTOR. UNE (120 VOLT) VOLTAGE CONTROL DEVICES,
SUCH AS THERMOSTATS AND AQUASTATS, WHICH CONTROL FRACTIONAL
HORSEPOWER, 120 VOLT MOTORS ARE FURNISHED BY MECHANICAL
CONTRACTOR, AND ARE WIRED BY ELECTRICAL CONTRACTOR.
7. SECURE AND PAY FOR PERMITS AND INSPECTIONS REQUIRED FOR THE ELECTRICAL
WORK.
8. WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF
LOCAL AND STATE CODES, AS WELL AS THE NATIONAL ELECTRICAL CODE, AS
INTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
9. CONSULT THE DRAWINGS, PRODUCT DATA AND SHOP DRAWINGS COVERING THE
WORK FOR VARIOUS OTHER TRADES, THE FIELD LAYOUTS OF THE CONTRACTORS FOR
THE TRADE AND MAKE ADJUSTMENTS ACCORDINGLY IN LAYING OUT THE
ELECTRICAL WORK.
10. WARRANT THAT EQUIPMENT AND ALL WORK IS INSTALLED IN ACCORDANCE WITH
GOOD ENGINEERING PRACTICE AND THAT ALL EQUIPMENT WILL MEET THE
REQUIREMENTS SPECIFIED. GUARANTEE AGAINST DEFECTS IN WORKMANSHIP AND
MATERIALS; REPAIR OR REPLACE ANY DEFECTIVE WORK, MATERIAL OR EQUIPMENT
WITHIN ONE YEAR FROM DATE OF ACCEPTANCE.
11. THE EXISTING ELECTRICAL AND TELEPHONE SERVICE, AND ALL EXISTING
COMMUNICATION SYSTEMS WITHIN THE BUILDING SHALL BE MAINTAINED
THROUGHOUT THE CONSTRUCTION PERIOD. ANY SERVICE SHUTDOWNS THAT MAY BE
REQUIRED SHALL BE SCHEDULED THROUGH THE OWNER AND SHALL BE DONE AT A
TIME AS DIRECTED BY THE OWNER. NO ADDITIONAL COMPENSATION SHALL BE
ALLOWED FOR THESE SHUTDOWN PERIODS EVEN THOUGH PREMIUM-TIME WORK MAY
BE REQUIRED. PROVIDE TEMPORARY SERVICE TO EQUIPMENT OR SYSTEMS THAT
CANNOT BE SHUTDOWN, AS DETERMINED BY OWNER.
12. PROVIDE A MINIMUM OF ONE WEEK'S NOTICE TO THE OWNER BEFORE ANY SERVICE
SHUTDOWN IS SCHEDULED.
13. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES.
THE DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY
TYPE, MODEL AND SIZE AND THUS ESTABLISH MINIMUM QUAUTIES WHICH
SUBSTITUTES MUST MEET TO QUAUFY FOR REVIEW. WHERE ONLY ONE MAKE IS
NAMED, IT SHALL BE PROVIDED. VERBAL REQUESTS OR APPROVALS SHALL NOT BE
BINDING ON THE ARCHITECT, ENGINEER OR OWNER. SHOULD THE CONTRACTOR
PROPOSE TO FURNISH MATERIALS AND EQUIPMENT OTHER THAN THOSE SPECIFIED,
HE SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS TO THE ARCHITECT AT
THE BID OPENING. INDICATE ANY ADDITIONS OR DEDUCTIONS TO THE CONTRACT
PRICE ON THE BID FORM.
14. EQUIPMENT AND MATERIALS USED ON THIS PROJECT SHALL BE NEW AND U.L.
LABELED FOR THE APPLICATION.
15. THE CONTRACTOR SHALL KEEP ONE COMPLETE SET OF THE CONTRACT WORKING
DRAWINGS ON THE PROJECT SITE ON WHICH HE SHALL RECORD ANY DEVIATIONS OR
CHANGES FROM SUCH CONTRACT DRAWINGS MADE DURING CONSTRUCTION. AFTER
THE PROJECT IS COMPLETED, RECORD SETS OF DRAWINGS SHALL BE DELIVERED TO
THE ARCHITECT IN GOOD CONDITION, AS A PERMANENT RECORD OF THE
INSTALLATION AS CONSTRUCTED.
16. PROVIDE NAMEPLATES ON PANELBOARDS, DISTRIBUTION EQUIPMENT, SAFETY
SWITCHES, MOTOR STARTERS, JUNCTION BOXES, AND CONTROL DEVICES. UNLESS
OTHERWISE INDICATED ON THE DRAWINGS, LETTERING SHALL INCLUDE THE NAME
OR DESIGNATION OF EQUIPMENT, HORSEPOWER, VOLTAGE RATING AND SERVICE
DESIGNATION. NAMEPLATES SHALL BE LAMINATED PHENOUC WITH A BLACK
SURFACE AND WHITE CORE. IDENTIFICATION WITH A DYMO TYPE INSTRUMENT IS
NOT PERMISSIBLE. THE INSIDE COVER OF ALL RECEPTACLE OUTLET PLATES SHALL BE
PERMANENTLY MARKED TO INDICATE THE PANEL AND CIRCUIT NUMBER OF THE
OUTLET. THE INSIDE COVER OF ALL BLANK PLATES FOR JUNCTION BOXES INSTALLED
SHALL BE PERMANENTLY MARKED TO INDICATE THE SYSTEM. IDENTIFICATION OF
BRANCH CIRCUITS SHALL BE TYPEWRITTEN ON DIRECTORY CARDS FURNISHED WITH
ALL PANELS AND PLACED IN THE CARD HOLDER ON THE DOOR. PROVIDE NEW
TYPEWRITTEN DIRECTORY CARDS WITH UPDATED SCHEDULES FOR ALL EXISTING
PANELS WITH NEW OR MODIFIED CIRCUITS.
17. AFTER INSTALLATION, TEST FOR GROUNDS, SHORT CIRCUITS AND PROPER FUNCTION
OF EACH SYSTEM AND RELATED WIRING. FAULTS IN THE INSTALLATION SHALL BE
CORRECTED.
18. INSULATION RESISTANCE TESTS SHALL BE MADE ON THE ELECTRICAL SYSTEM WITH
AN APPROVED MEGOHMMETER.
19. A GROUND CONTINUITY TEST SHALL BE MADE ON THE ENTIRE GROUNDING SYSTEM
FROM THE SERVICE TO EVERY OUTLET.
20. AFTER ALL TESTS AND ADJUSTMENTS HAVE BEEN COMPLETED, CLEAN ALL
EQUIPMENT LEAVING EVERYTHING IN WORKING ORDER AT THE COMPLETION OF THIS
WORK. CLEAN UGHTING FIXTURES, OUTLET BOX PLATES, PANEL AND CABINET
INTERIORS AND EXTERIORS, ETC., OF DIRT, DUST , DEBRIS AND PAINT, AFTER ALL
OTHER TRADES HAVE COMPLETED THEIR WORK.
21. PROVIDE A TEMPORARY ELECTRICAL SERVICE ADEQUATE IN SIZE FOR HEATING, FOR
THE USE OF ALL TRADES AND FOR THE LIGHTING OF EACH ROOM DURING
CONSTRUCTION. TEMPORARY WIRING SHALL BE TO OSHA REQUIREMENTS.
TEMPORARY SERVICE CAN BE EXTENDED FROM THE OWNER'S EXISTING POWER
DISTRIBUTION SYSTEM. THE OWNER MUST APPROVE OF THE POINT OF SUPPLY, THE
METHOD OF EXTENSION AND THE ROUTING OF NECESSARY TEMPORARY FEEDERS.
PROVIDE A TEMPORARY TELEPHONE SERVICE FOR THE USE OF ALL TRADES DURING
CONSTRUCTION.
22. DO ALL CUTTING AND PATCHING IN EXISTING CONSTRUCTION AS NECESSARY FOR
INSTALLATION OF THIS WORK. HAVE CUTTING DONE BY SKILLED MECHANICS AS
CAREFULLY AS POSSIBLE AND WITH AS LITTLE DAMAGE AS POSSIBLE.
23. DEMOUTION OF EXISTING ELECTRICAL EQUIPMENT MAY BE A PART OF THE ELECTRICAL
WORK. REFER TO THE DRAWINGS FOR EXACT REQUIREMENTS.
ELECTRICAL SPECIFICATIONS
SECTION 16050 - BASIC MATERIALS AND METHODS
1. ALL BOXES SHALL BE RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE
INDEPENDENT OF THE CONDUIT SYSTEM. ALL BOXES SHALL BE 4" SQUARE
BOXES MINIMUM WITH RAISED COVERS SUITABLE FOR THE WALL MATERIAL.
2. RACEWAYS:
A. CONDUIT SHALL BE HEAVY WALL GALVANIZED STEEL OR INTERMEDIATE
GRADE STEEL IN EXTERIOR MASONRY WALLS; IN MASONRY WALLS BELOW
GRADE; IN CRAWL SPACES; IN THE GROUND; IN CONCRETE FLOORS, WALLS OR
SLABS; AND IN DAMP OR WET LOCATIONS. EXPOSED CONDUITS IN HIGH
TRAFFIC AREAS WHERE CONDUITS ARE SUBJECT TO PHYSICAL ABUSE SHALL BE
HEAVY WALL RIGID GALVANIZED STEEL TO A LEVEL OF 8 FEET ABOVE THE
FINISHED FLOOR. ALL OTHER INTERIOR CONDUITS SHALL BE ELECTRICAL
METALLIC TUBING (EMT), UNLESS OTHERWISE NOTED ON THE DRAWINGS OR
WITHIN THESE SPECIFICATIONS. CONDUITS SHALL BE 3/4" TRADE SIZE, MINIMUM,
UNLESS OTHERWISE NOTED ON THE DRAWINGS OR WITHIN THESE SPECIFICATIONS.
B.
FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOXES TO RECESSED
UGHTING FIXTURES, 6 FT. IN LENGTH. INSTALLATION OF MANUFACTURED WIRING
SYSTEMS SHALL COMPLY WITH ARTICLE 604 OF THE NATIONAL ELECTRICAL
CODE. ALL BRANCH CIRCUIT HOMERUN CONDUITS WITHIN THE CEILING SPACE
COMPLETE TO THE PANELBOARDS SHALL BE EMT CONDUIT. FLEXIBLE CONDUIT
MAY NOT BE UTILIZED TO WIRE FIXTURES, OUTLETS, ETC IN A DAZY CHAIN
FASHION.
C. CONDUIT CONNECTIONS TO MOTORS SHALL BE FLEXIBLE METAL CONDUIT
"SEAL -TITE" TYPE "UA" AS MANUFACTURED BY THE AMERICAN BRASS
COMPANY OR EQUIVALENT AND SHALL BE OF THE SAME SIZE AS THE FEEDER
CONDUIT.
D. CONDUIT CONNECTIONS TO UNDERCABINET TYPE LIGHTING FIXTURES SHALL BE
3/8" FLEXIBLE METAL CONDUIT OR MC TYPE CABLE FROM THE WALL OUTLET
BOX TO THE FIXTURE HOUSING.
3. WIRING DEVICES:
A. LOCAL LIGHT SWITCHES SHALL BE 20 AMPERE, 120/277 VOLTS, AC
SPECIFICATION GRADE, WITH GROUNDING TERMINAL, AS MANUFACTURED BY
HUBBELL, OR EQUIVALENT, #CS -122 SERIES.
B. FLUORESCENT DIMMERS SHALL BE LUTRON "NOVA T -STAR" SERIES, #NTF -10 FOR
120 VOLT, #NTF -40 -277 FOR 277 VOLT. 3 -WAY, 2 LOCATION FLUORESCENT
DIMMERS SHALL BE LUTRON °NOVA T -STAR" SERIES, #NTF -103P FOR 120 VOLT,
#NTF -103P -277 FOR 277 VOLT.
C. INCANDESCENT DIMMERS SHALL BE LUTRON "NOVA T- -STAR" UNEAR SLIDE
SERIES - FOR UP TO 1500 WATT DIMMERS AND LUTRON "NOVA" LINEAR SLIDE
SERIES FOR 2000 WAIT DIMMERS.
D. DUPLEX RECEPTACLES SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING.
GENERAL PURPOSE "SPECIFICATION GRADE" DUPLEX RECEPTACLES: HUBBELL
#CR5352. ISOLATED GROUND DUPLEX RECEPTACLES: HUBBELL #CR5352 IG -
ORANGE. HOSPITAL GRADE DUPLEX RECEPTACLES: HUBBELL #8300H. TAMPER
RESISTANT "SAFETY TYPE" DUPLEX RECEPTACLES: HUBBELL #HBL8300SG.
E. DUPLEX RECEPTACLES WHERE INDICATED ON THE DRAWINGS OR WHERE
REQUIRED BY CODE, SHALL HAVE AN INTEGRAL GROUND FAULT PROTECTOR
AND SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING: HUBBELL #GFR5352.
GROUND FAULT RECEPTACLES SHALL NOT BE THRU - WIRED. PROVIDE
INDIVIDUAL DUPLEX RECEPTACLES AS SHOWN ON THE DRAWINGS.
HOSPITAL GRADE GROUND FAULT DUPLEX RECEPTACLES: HUBBELL #HGF8300.
F. ALL SWITCHES, DIMMERS, AND RECEPTACLES SHALL BE IVORY
UNLESS OTHERWISE INDICATED WITHIN THESE SPECIFICATIONS. VERIFY COLOR
WITH THE ARCHITECT PRIOR TO PROCUREMENT OF THE DEVICES. ALL
COVERPLATES SHALL BE SMOOTH HIGH IMPACT
THERMOPLASTIC FINISH WITH COLOR TO MATCH THE DEVICES. EMERGENCY
RECEPTACLES AND SWITCHES SHALL BE RED, WITH COVERPLATES TO MATCH
THE FINISH OF THE OTHER COVERPLATES PROVIDED IN THE AREA. IN
UNFINISHED AREAS, USE CADMIUM PLATED, ROUND CORNER, STEEL
COVERPLATES FOR SURFACE MOUNTED OUTLET BOXES. BOTH THE WIRING
DEVICES AND THE COVERPLATES SHALL BE BY THE SAME MANUFACTURER.
G. MANUAL MOTOR STARTERS SHALL BE WESTINGHOUSE TYPE "MS" SERIES OR
EQUIVALENT, WITH PILOT LIGHT, OVERLOADS AND ON /OFF SWITCH; FLUSH
MOUNTED IN FINISHED AREAS. MANUAL MOTOR STARTERS SHALL BE
MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, ITE OR ALLEN BRADLEY.
H. THE FOLLOWING ARE EQUIVALENT WIRING DEVICES:
1. RECEPTACLES: #5362 SERIES MANUFACTURED
BY PASS AND SEYMOUR OR LEVITON.
2. LIGHT SWITCHES: PASS AND SEYMOUR #20AC1 SERIES OR LEVITON #1221
SERIES.
3. DIMMERS: NO OTHER MANUFACTURERS ARE ACCEPTABLE.
4. WIRE AND CABLE FOR BRANCH CIRCUITS AND FOR FEEDERS SHALL BE 600 VOLT, TYPE
THHN/THWN COPPER ONLY, UNLESS OTHERWISE INDICATED ON THE DRAWINGS.
MINIMU FOR POWER AND LIGHTING BRANCH CIRCUITS SHALL BE #12.
5. SAFETY SWITCHES SHALL BE HEAVY DUTY FUSIBLE OR NONFUSIBLE TYPE AS
INDICATED ON THE DRAWINGS, AND SHALL BE SUITABLE FOR THE VOLTAGE AND
CURRENT RATINGS AS SHOWN ON THE DRAWINGS.
6. FUSES RATED 600 AMPERES OR LESS, 600 VOLTS OR LESS, SERVING ALL LOADS
SHALL BE U.L CLASS RK1, DUAL ELEMENT, TIME DELAY AS MANUFACTURED BY
BUSSMANN, OR APPROVED EQUIVALENT AS MANUFACTURED BY RELIANCE FUSE,
GOULD SHAWMUT OR UTTELFUSE , GENERAL ELECTRIC OR S & C.
7. FUSES RATED 600 AMPERES OR MORE, 600 VOLTS OR LESS, SERVING ALL LOADS
SHALL BE U.L. CLASS L, BUSSMANN, TIME DELAY TYPE KRP -C_SP, OR APPROVED
EQUIVALENT AS MANUFACTURED BY RELIANCE FUSE, GOULD SHAWMUT OR LITTELFUSE ,
GENERAL ELECTRIC OR S & C ARE APPROVED.
8. ALL MOTOR STARTERS SHALL BE COMBINATION TYPE. STARTERS SHALL INCLUDE A
FUSIBLE SAFETY SWITCH, A STARTER WITH THREE OVERLOAD DEVICES, AND A
CONTROL CIRCUIT TRANSFORMER. THE ENCLOSURE SHALL BE NEMA TYPE 1, UNLESS
OTHERWISE INDICATED ON THE DRAWINGS. EACH COMBINATION STARTER SHALL
INCLUDE A CONTROL CIRCUIT TRANSFORMER WITH A 120 VOLT SECONDARY
CONNECTION UNLESS OTHERWISE INDICATED ON THE DRAWINGS. ONE SIDE OF THE
SECONDARY WINDING SHALL BE FUSED AND THE OTHER SIDE GROUNDED. STARTERS
SHALL HAVE A GREEN RUNNING PILOT LIGHT, A HAND -OFF- AUTOMATIC SELECTOR
SWITCH AND A MINIMUM OF TWO NORMALLY OPEN AND TWO NORMALLY CLOSED
AUXILIARY CONTACTS, READY FOR CONTROL WIRING CONNECTIONS.
9. DISCONNECT SWITCHES AND MOTOR STARTERS SHALL BE MANUFACTURED BY
SQUARE D', GENERAL ELECTRIC, SIEMENS /ITE, CUTLER HAMMER /WESTINGHOUSE, OR
ALLEN BRADLEY.
10. ANY CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS AND WALLS SHALL
BE FIRE STOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE SEALED
IN ACCORDANCE WITH UL FIRE RESISTANCE HANDBOOK, VOLUME II AND SHALL BE
RATED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS OR WALLS PENETRATED.
11. RACEWAY INSTALLATION:
A. CONDUITS SHALL BE CONTINUOUS AND SECURED TO ALL BOXES IN SUCH A
MANNER THAT EACH CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS
FROM THE POINT OF SERVICE TO ALL OUTLET BOXES. RUN CONDUITS
CONCEALED UNLESS OTHERWISE INDICATED.
B. IN REMODELED AREAS WHERE IT IS NOT POSSIBLE TO INSTALL CONCEALED
CONDUIT, PERMISSION MUST BE OBTAINED FROM THE ARCHITECT TO RUN
SURFACE WIREMOLD OR CONDUIT. THE ROUTING AND ELEVATION OF SUCH
SURFACE MOUNTED RACEWAYS MUST BE COORDINATED WITH THE ARCHITECT
BEFORE INSTALLATION. EXPOSED RACEWAYS SHALL BE PAINTED TO MATCH
ADJACENT FINISHES.
C. INDIVIDUAL BRANCH CIRCUITS ARE SHOWN ON THE DRAWINGS FOR CLARITY.
LIGHTING AND RECEPTACLE CIRCUITS MAY BE GROUPED FOR HOMERUNS,
WITH A MAXIMUM OF (2) OR (3) CIRCUITS PER HOMERUN, DEPENDING ON THE
SYSTEM. NEUTRAL CONDUCTORS IN RECEPTACLE CIRCUITS SERVING DATA
EQUIPMENT LOADS SHALL NOT BE SHARED.
D. WIRING FROM LEGALLY REQUIRED EMERGENCY AND STANDBY POWER
GENERATION SOURCES SHALL BE KEPT INDEPENDENT OF EACH OTHER AND
INDEPENDENT OF ALL OTHER BRANCH CIRCUIT WIRING, AND SHALL NOT ENTER
THE SAME RACEWAY, CABLE, BOX, OR CABINET WITH OTHER WIRING, UNLESS
SPECIFICALLY ALLOWED BY THE NATIONAL ELECTRICAL CODE.
11. WIRE AND CABLE INSTALLATION:
A. PULL WIRE AND CABLES INTO CONDUIT USING IDEAL INDUSTRIES "YELLOW
190 ", OR EQUIVALENT.
B. COLOR CODE WIRE AND CABLE FOR CIRCUITS AS CALLED FOR IN THE NATIONAL
ELECTRICAL CODE. COLOR CODING OF FEEDERS SHALL BE BY MEANS OF
COLORED TAPE AT TERMINALS.
12. WIRING DEVICE INSTALLATION:
A. ADJACENT DEVICES SHALL BE MOUNTED IN GANGED BOXES WITH COMMON COVER
PLATES.
B. VERIFY MOUNTING HEIGHTS AND LOCATIONS WITH THE ARCHITECT BEFORE
ROUGH -IN. REFER TO DETAILS AND INTERIOR WALL ELEVATIONS SHOWN ON
THE ARCHITECTURAL DRAWINGS.
C. OUTLETS SHALL NOT BE INSTALLED BACK TO BACK.
D. ALL RECEPTACLES SHALL BE MOUNTED WITH THE GROUND OPENING ABOVE
THE PHASE AND NEUTRAL OPENINGS.
E. ALL DEVICES SHALL BE SECURED WITH MORE THAN A SINGLE SCREW.
13. ALL HARDWARE, SUPPORTS, HANGERS, BRACKETS, ANGLE IRON, CHANNELS, RODS AND
CLAMPS NECESSARY TO INSTALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED TO SUIT
THE FIELD CONDITIONS AND THE APPLICATIONS INTENDED AS SHOWN ON THE
DRAWINGS. THE USE OF PERFORATED STRAPS IS NOT PERMITTED. NO 1. It CHMENTS
AND
SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY.
14. ALL EQUIPMENT MOUNTED ON EQUIPMENT ROOM WALLS SHALL BE ATTACHED TO 3/4"
PLYWOOD BOARDS, PAINTED WITH FIRE RESISTANT PAINT.
15. DISCONNECT SWITCHES MOUNTED ON OR ADJACENT TO MECHANICAL AND BUILDING
EQUIPMENT SHALL BE LOCATED TO ALLOW THE PROPER WORKING CLEARANCE AS
DEFINED IN ARTICLE 110 OF THE NATIONAL ELECTRICAL CODE.
16. ELECTRICAL INSTALLATIONS IN HOLLOW SPACES, VERTICAL SHAFTS, AND
VENTILATION OR AIR- HANDLING DUCTS SHALL BE MADE SO THAT THE POSSIBLE
SPREAD OF FIRE OR PRODUCTS OF COMBUSTION WILL NOT BE SUBSTANTIALLY
INCREASED. OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH
FIRE-RESISTANT-RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS SHALL BE
FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE
RATING. MAINTAIN A MINIMUM OF 24 -IN. HORIZONTAL SEPARATION BETWEEN
BOXES INSTALLED ON OPPOSITE SIDES OF WALLS.
SECTION 16400 - SERVICE AND DISTRIBUTION
1. GROUND ALL ELECTRICAL SYSTEM CONDUITS, MOTORS, PANELS AND OTHER
EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN
ACCORDANCE WITH ALL PROVISIONS OF THE NATIONAL ELECTRICAL CODE, STATE
BUILDING CODE AND LOCAL OR REGIONAL CODES.
2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED
GROUNDING CONDUCTOR INSTALLED WITH FEEDER AND BRANCH CIRCUIT
CONDUCTORS IN ALL CONDUITS. GROUNDING CONDUCTORS SHALL BE SIZED IN
ACCORDANCE WITH N.E.C. ARTICLE 250.
3. SYSTEM NEUTRAL CONDUCTORS SHALL BE GROUNDED AT THE SOURCE. NEUTRAL
CONDUCTORS SHALL NOT BE USED FOR EQUIPMENT GROUNDING.
4. THE GROUNDING CONDUCTOR FOR BRANCH CIRCUITS FEEDING ISOLATED GROUND
RECEPTACLES SHALL BE CONNECTED ONLY AT THE ISOLATED GROUND RECEPTACLE
GROUND TERMINALS, AND AT THE GROUND BUS OF THE SERVING PANEL.
5. FURNISH AND INSTALL BRANCH CIRCUIT BREAKER PANELBOARDS EQUIPPED WITH
CIRCUIT BREAKERS, WITH FRAME AND TRIP RATINGS LISTED ON THE DRAWINGS.
CIRCUIT BREAKERS SHALL BE THERMAL- MAGNETIC, MOLDED CASE BOLT -ON TYPE.
ALL CURRENT CARRYING PARTS OF THE BUS STRUCTURE SHALL BE TIN- PLATED
ALUMINUM. EACH PANELBOARD SHALL CONTAIN A GROUNDING BUS.
6. EACH PANELBOARD SERVED DIRECTLY BY A TRANSFORMER SECONDARY SHALL
HAVE A MAIN CIRCUIT BREAKER OR OTHER MAIN OVERCURRENT PROTECTION, SIZED
IN ACCORDANCE WITH ARTICLE 240 OF THE NATIONAL ELECTRICAL CODE.
7. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, SIEMENS /ITE, GENERAL
ELECTRIC OR CUTLER HAMMER /WESTINGHOUSE.
8. PANELS SHALL BE MOUNTED SO THAT TOP OF THE CABINET IS AT 6' -0" ABOVE FLOOR.
A GLAZED DIRECTORY FRAME SHALL BE PROVIDED INSIDE EACH PANEL DOOR AND
SHALL BE OF SUFFICIENT SIZE TO GIVE A COMPLETE DESCRIPTION OF EACH CIRCUIT.
TYPED DIRECTORY CARDS SHALL BE PROVIDED LISTING EACH CIRCUIT SERVED.
9. THE BRANCH CIRCUIT NUMBERS USED ON THE DRAWINGS SHALL BE APPLIED FOR THE
CONSTRUCTION. HOWEVER, AT THE COMPLETION OF THE WORK, CIRCUIT NUMBER
ADJUSTMENTS SHALL BE MADE AS REQUIRED TO PROVIDE BALANCED PHASE
LOADING ON EACH PANELBOARD.
10. FLUSH MOUNTED PANELBOARDS SHALL BE INSTALLED WITH A MINIMUM OF THREE
EMPTY 3/4" CONDUITS STUBBED UP TO THE NEAREST ACCESSIBLE CEILING SPACE FOR
CONVENIENT FUTURE EXPANSION.
11. TRANSFORMERS SHALL BE 115 DEGREES C. TEMPERATURE RISE ABOVE A 40 DEGREES
C. AMBIENT. ALL INSULATING MATERIALS SHALL BE IN ACCORDANCE WITH NEMA
ST20 STANDARD FOR A 185 DEGREES C. UL COMPONENT RECOGNIZED INSULATION
SYSTEM. SOUND LEVELS SHALL NOT EXCEED NEMA STANDARDS. TRANSFORMER
SHALL HAVE (4) 2 -1/2% FULL CAPACITY PRIMARY TAPS.
12. TRANSFORMERS SHALL. BE AS MANUFACTURED BY SQUARE D, SIEMENS /ITE, GENERAL
ELECTRIC, OR CUTLER HAMMER /WESTINGHOUSE.
13. PROVIDE A 6" CONCRETE PAD FOR FLOOR MOUNTING OF EACH TRANSFORMER RATED
75 KVA AND ABOVE, AND FOR SMALLER TRANSFORMERS IF INDICATED ON THE
DRAWINGS.
SECTION 16500 - LIGHTING
1. RECESSED INCANDESCENT FIXTURES SHALL HAVE THERMAL CUTOUT PROTECTION
PER MANUFACTURER'S SPECIFICATIONS.
2. RECESSED FIXTURES SHALL BE PROVIDED TO BE COMPATIBLE WITH THE CEILING
TYPES INSTALLED. VERIFY ALL CEILING TYPES WITH THE DIVISION 1 CONTRACTOR,
OR WITH THE ARCHITECT BEFORE PROCUREMENT OF FIXTURES.
3. FLUORESCENT ELECTRONIC BALLASTS SHALL BE ONE, TWO, THREE OR FOUR LAMP
TYPE TO ACCOMMODATE THE FIXTURES AND SWITCHING SPECIFIED, AND SHALL BE
U.L LISTED, CLASS "P ". FLUORESCENT ELECTRONIC BALLASTS SHALL BE ADVANCE
"CENTIUM" INSTANT START SERIES FOR T8 LAMPS OR EQUAL BY VALMONT,
MOTOROLA, OR MAGNETEK /TRIAD. BALLASTS SHALL HAVE A MINIMUM POWER
FACTOR OF 90 %, A MINIMUM BALLAST FACTOR OF 85%, A MAXIMUM CREST FACTOR
OF 1.7, AND A MAXIMUM TOTAL HARMONIC DISTORTION OF 10 %.
4. FLUORESCENT COMPACT FLUORESCENT LAMP BALLASTS SHALL BE ENCAPSULATED
TYPE - HIGH POWER FACTOR AND POWER FACTOR CORRECTED OR ELECTRONIC AS
DESCRIBED IN THE LIGHTING FIXTURE SCHEDULE ON THE DRAWINGS. BALLASTS
SHALL BE PROVIDED AS RECOMMENDED BY THE FIXTURE MANUFACTURER.
5. HIGH INTENSITY DISCHARGE BALLASTS SHALL BE CONSTANT WATTAGE, HIGH POWER
FACTOR TYPE, WITH LOW NOISE.
6.
INCANDESCENT LAMPS SHALL BE 130 VOLT RATED. A -LAMPS SHALL BE FROSTED.
PROVIDE INCANDESCENT LAMPS AS RECOMMENDED BY THE FIXTURE
MANUFACTURER.
7. FLUORESCENT UNEAR AND U -LAMPS SHALL BE T -8, 3500 DEG K.
8. COMPACT FLUORESCENT LAMPS SHALL BE 3500 DEG K.
9. HIGH PRESSURE SODIUM LAMPS SHALL BE CLEAR OR COATED AS RECOMMENDED BY
THE FIXTURE MANUFACTURER.
10. METAL HAUDE LAMPS SHALL BE CLEAR OR COATED AS RECOMMENDED BY THE
FIXTURE MANUFACTURER, AND SHALL BE 3700K UNLESS OTHERWISE SPECIFIED IN
THE UGHTING FIXTURE SCHEDULE.
A. FOR OPEN RELECTOR HIGH INTENSITY DISCHARGE FIXTURES, PROVIDE
LAMPS LISTED FOR THE APPLICATION AS RECOMMENDED BY THE
MANUFACTURER.
11. ALL LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, SYLVANIA,
WESTINGHOUSE /PHILLIPS, OR VENTURE. PROVIDE CLEAR, LEXAN LAMP SLEEVES
WITH END CAPS FOR EXPOSED FLUORESCENT LINEAR LAMPS. PROVIDE SPARE LAMPS
AMOUNTING TO 10% (MINIMUM OF 3) OF EACH TYPE AND SIZE OF EACH LAMP USED ON
THE PROJECT.
12. RECESSED AND SURFACE MOUNTED FIXTURES MOUNTED IN, OR ON CEILINGS OTHER
THAN ACCESSIBLE LAY -IN CEILING SYSTEMS, SHALL BE SECURELY SUPPORTED IN A
MANNER APPROVED BY THE ARCHITECT. MOUNTING SHALL ALSO BE IN
ACCORDANCE WITH NATIONAL ELECTRICAL CODE ARTICLE 410, AND AS
RECOMMENDED BY THE FIXTURE MANUFACTURER.
13. RECESSED FIXTURES IN ACCESSIBLE LAY -IN CEILING SYSTEMS SHALL BE SUPPORTED
AS FOLLOWS:
A. THE GRID SYSTEM TEES SHALL BE SUPPORTED AT EACH CORNER OF EACH
FIXTURE WITH A SUSPENDED CEILNG SUPPORT WIRE UP TO A BUILDING
STRUCTURAL MEMBER, OR UP TO THE STRUCTURAL DECK.
B. EACH FIXTURE SHALL ALSO BE SECURELY FASTENED TO THE GRID SYSTEM
TEES BY MECHANICAL MEANS, SUCH AS BOLTS, SCREWS, RIVETS OR BY CLIPS
IDENTIFIED FOR USE WITH THE TYPE CEILING FRAMING MEMBER INSTALLED.
14. ALL LIGHTING FIXTURES (INCLUDING "NORMALLY -OFF" EMERGENCY FIXTURES) THAT
ARE CAPABLE OF BEING AIMED SHALL BE AIMED BY THE CONTRACTOR FOR THE
OPTIMUM COVERAGE OF THEIR TASK, TO THE SATISFACTION OF, AND UNDER THE
DIRECTION OF THE ARCHITECT.
SECTION 16700 - COMMUNICATIONS
1. COMBINATION TELEPHONE /DATA OUTLET BOXES SHALL BE 4 INCHES SQUARE
WITH SINGLE GANG PLASTER RINGS, UNLESS OTHERWISE NOTED.
2. TELEPHONE -ONLY, DATA -ONLY, FAX AND PAY TELEPHONE OUTLETS SHALL
BE SIMILAR.
3. BLANK COVERPLATES SHALL BE PROVIDED FOR ALL UNUSED OUTLETS.
4. ALL CONDUITS REQUIRED FOR COMBINATION TELEPHONE /DATA OUTLETS AS
SHOWN ON THE DRAWINGS SHALL BE INSTALLED COMPLETE WITH PULL WIRES.
5. PROVIDE CONDUIT FROM EACH OUTLET UP TO THE NEAREST ACCESSIBLE
CORRIDOR CEILING SPACE AND PROVIDE A PLASTIC GROMMET AT EACH
STUB.
6.
7.
PROVIDE MISCELLANEOUS COMMUNICATION SYSTEM DEVICES AS SHOWN AND
SPECIFIED ON THE DRAWINGS.
INCLUDE SUFFICIENT WIRING, CONDUIT TERMINATIONS, ELECTRICAL BOXES,
AND ALL OTHER NECESSARY MATERIAL AS RECOMMENDED BY THE SYSTEM
SUPPLIERS.
f
ENERGY STAR
ALL ELECTRICAL POWER DISTRIBUTION
EQUIPMENT SHALL HAVE THE "ENERGY
STAR" CERTIFICATION LABEL.
REVIEWED FOR E.
CODE. CE
y �� �'� NEC
NFPA
A ,I ins
City f'‘Y SI®N
pr-r.)
CFI''
FEB 19 2003
MN=
& ASSOCIATES
> Retail Design & Development
345 SPRINGSIDE DRIVE TEL 330 / 666 -6767
AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334
STORE #753
WESTFIELD SOUTHCENTER
SPACE #1010
466 SOUTHCENTER MALL
TUKWILA, WA 98188
CONSULTANT:
DRAWN BY:
STADELMAN
ISSUE / DATE:
ISSUE 1 - CONSTRUCTION DOCUMENTS
01- 302008
REVISION :
02 -13 -08 -PER LANDLORD COMMENTS
-AKS
SHEET TITLE :
ELECTRICAL
SPECIFICATIONS
SHEET NO. :
E600