Loading...
HomeMy WebLinkAboutPermit EL08-0158 - WESTFIELD SOUTHCENTER MALL - CLARKSCLARKS 466 SC MALL 07 -19.08 ELO8-158 CitAbf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 466 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -158 Issue Date: 06/10/2008 Permit Expires On: 12/07/2008 Tenant: Name: CLARKS Address: 466 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DAVID A LEVY Phone: 330 666 -6767 Address: 345 SPRINGSIDE DR , AKRON OH Contractor: Name: M K ELECTRIC INC Address: PO BOX 612 , BUCKLEY WA Contractor License No: MKELEKE957PO Phone: 360 -829 -5362 Expiration Date: 10/20/2009 DESCRIPTION OF WORK: Value of Electrical: $35,000.00 Fees Collected: $820.00 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: • I hereby certify that I have read and Hvk Date: UtA t,01 4 ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erfo c f wo k. I am authorized to sign and obtain this electrical permit. Signature: 6Zi t.�!LD /D Date: /0 Print Name: ��`�" /�'S ?er/11.s./ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -158 Printed: 06 -10 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 466 SOUTHCENTER MALL TUKW Suite No: Tenant: CLARKS PERMIT CONDITIONS Permit Number: EL08 -158 Status: ISSUED Applied Date: 02/19/2008 Issue Date: 06/10/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: / J ��- VOS7t�/ GC�i Date: / 4912 doc: Cond -Elec EL08 -158 Printed: 06 -10 -2008 i CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. euvii.- tc2 Project No. Pos- o1[0 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: L oA2.0 - Opp C� Site Address: Alp 'Gila\\ Suite Number: kfiNgilio Floor: Tenant Name: C \ac 'S Property Owners Name: v ie.\fcie, cA MailingAddress:W \tppA ■►\t \CC_ \` . -V \aer L'Angeks X0025 City tIt State Lip New Tenant: ❑ Yes ❑..No CONTACT PERSON - Who do we contact when your permit is ready to be issued -T0 be. (e�recmtne c4 Name: J.a.V 1 A Let, Mailing Address: 3L* S r'i rtS 1 d e b le E -Mail Address: Day Telephone: Akrao City M- iE43 State Zip Fax Number: 33a - L(04. ELECTRICAL CONTRACTOR INFORMATION —'T> oe. Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): S ,,r.� CX�� . Cs0 Scope of Work (please provide detailed information): 9(.4. i falevd i Stuff l es -rare ` r e r,a..n.'i- Z rn p rvV e-m .if a n C la r k.S p Will service be altered? ❑ Yes Et No Adding more than 50 amps? ❑ Yes [` No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel [Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: Xl""uget Sound Energy ❑ Seattle City Light II 'ipphcattens \Fern.- Apphcuions On I me 4 -7111: - I-k..ln<al perms Apphcation.doc bh Page 1 of RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings 5140.00 (including an attached garage) ❑ Garages, pools. spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm. furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added /altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits S 10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added /altered without service change S50.00 (6 or more circuits) $7.00 ca ❑ Meter mast repair $65.00 ❑ Low voltage systems S55.00 (alarm, furnace thermostat) MULTi- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service S80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. i HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THiS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THiS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: MA1�t -, > t FE.DDIcz, -b Mailing Address: e33 cS. o4 C.+ Fee ,Trai le-e" *3 Day Telephone: kw; 1a. City Date: 2111/or 2. 44, - 4:TD Z - 4,..e)-1 WA 9 8181 State Lip Date Application Accepted: ►,91.[t H 'Apphcaionsronn - Application. Un I ire 4 -200" - hleancal Permit 'lpphcatuon.Joc bh Date Application Expires: a I (1. Staff Initials: Page 2 of 2 SET RECEIPT RECEIPT NO: R08 -02032 Initials: JEM User ID: 1165 Payee: SCOTT THOMAS CONSTRUCTION Payment Date: 06/09/2008 Total Payment: 3,129.00 SET ID: 0304A SET TRANSACTIONS: Set Member Amount D08 -089 1,848.75 yEL0T8158' 656.00 M08 -044 556.25 PGO8 -047 68.00 TOTAL: 1,848.75 TRANSACTION LIST: Type Method Description SET NAME: CLARKS Amount Payment Check 157397 ACCOUNT ITEM LIST: Description TOTAL: Account Code 3,129.00 3,129.00 Current Pmts BUILDING - NONRES ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES PLUMBING - NONRES STATE BUILDING SURCHARGE 000/322.100 000.322.101.00.0 000.322.102.00.0 000/345.830 000.322.103.00.0 000/386.904 TOTAL: 1,784.25 656.00 451.00 165.25 68.00 4.50 3,129.00 3421 06/09 9711 TOTAL 3129.00 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http.• //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -00458 Initials: JEM Payment Date: 02/19/2008 User ID: 1165 Total Payment: 1,524.55 Payee: DAVID A LEVY & ASSOCIATES SET ID: S000000961 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -089 1,321.05 i EL'`08 .V 164.00 M08 -044 7.50 PG08 -047 32.00 TOTAL: 1,524.55 TRANSACTION LIST: Type Method Description Amount Payment Check 11959 1,524.55 TOTAL: 1,524.55 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000/322.100 97.75 000.345.832.00.0 164.00 000/345.830 1,262.80 TOTAL: 1,524.55 37 90 02/1q 1710 TOTAL 1521-.55 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: tp, Type of Inspecti ! Ad } /9 k Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: oved per applicable codes. Corrections required prior to approval. COMMENTS: fr/it/2L- Ins pe /tL 601W.2i241/�v f/ Dat //9 J El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. e CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 9 Project: ex. Alex 1 > Type of Inspection: �00 r ,eF kS Address: Li up Date Called: — 'JO pi tE p4y„I q coct6.tr c airl CbdNk_Teh t,) I K1 Cod Nei-r 'Ai (fk-du1 Special Instructions: Date Wanted: - v Qt IJCt. QVrit 1Z C' t c s t r tea t le p.m. Requester: P Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: — 1I [(46( 1n't 1403tL5 midPmt r ,eF kS — 'JO pi tE p4y„I q coct6.tr c airl CbdNk_Teh t,) I K1 Cod Nei-r 'Ai (fk-du1 Q wk _ rI fur L cou,..lp /a 2 4.3 1,4 lea avectot7 - v Qt IJCt. QVrit 1Z C' t c s t r ‹ . Co , 5 RAJ 24 P t 5 J P.Pagt.fr tic- Inspector: (3044/(X, JDate: Di /rg/s JJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: �� �� Type of Inspection: 2400 Address: �g 6 � Date Called: Special Instrrictions: Date Wanted: 1 /I? Requester: �� Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 07 17 Date: /CA' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: iarsli anbi,sYwx Ie.... 1, • .. . INSPECTION NO. INSPECTION RECORD it,� _ S� Retain a copy with permit c PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ��� � � Type of Inspection: 2-100 Address: 64 M".'pm/ Date Called: Special Ins uctions: Date Wanted: t 7/i i P.m. Requester: J Phone No: Approved per applicable codes. U Corrections required prior to approval. COMMENTS: Inspector: b0ate A? (I 1 O\S) ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: - 1..- _ ...m.WINROF` ----^3 s-"- - r - - .16.wLale • nee ti alOLostebr. M.,.,•01%. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit toy- r PERMIT NO. (206)431 -3670 Project:4� Type of Inspection: 703 Address: Litt rite/t, Date Called: Special Instructions: Date Wanted: f / L p.r p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. 'COMMENTS: — wits uski Covet e \OJ(.o} IN 'Inspector: Date: 61 119 j', ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: d.� 4 INSPEC%N NO. INSPECTION RECORD Retain a copy with permit PERMIT NO_ CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: f� Ty1:76rgctio .3 Vo Dattee Called: Special Instructions: Date Wanted: , (..'-/S7 Requester: Phone No: proved per applicable codes. El Corrections required prior to approval. 4 oMMEN -rm — —700/ p/4 — (st/ A A f 3 7 0 -6 s /04 c),< --- . p f/ �t• 1 5( FP/ r 9-G c)ai, v J. 0 -__ Ai -s---/ inn - 1-1-"Ari I / 6 Inspe =;i1 /( %t`iTWH Datej El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti Project: Type of Inspection:..., 1..7 / iciiiZZ Date Called: f TG/ /x/%25 j--:' /, 6 e / : C✓ Special Instructions: . Date Wanted: ' r 2_ 5 Cd p.m. Requester: Phone No: EjApproved per applicable codes. rrections required prior to approval. COMMENTS: i)/( (U /1 A hi/ 6- ,A1/77 p.otio / i,V C G %• Cv.iJ if /Al 444.14z,-_5- _ 1 c z,- f TG/ /x/%25 j--:' /, 6 e / : C✓ Ins pec r Date :W.7_ S /6 r El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: eGre4lx.c.�.. • M. — - �..- --�..J bM. • ai,. i.ae.Y..,.r a�s1i�"rt.�. +iwamosn�;E.• r,. ....te sta,_: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: C_ Addfess� ,c—C-- i)i, L Date Called: Special Instructions: Date Wanted: // Requester: Phone No: roved per applicable codes. Corrections required prior to approval. COMMENTrJ 69/4_,— W 1 t c v(I f/ --- 4-Ws/ , 9oC # ,I' /57 4n0/1 % Inspec /` ` &r1&6/u/Q'I Date:` //?/i g ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 6 re__ til _ ... i Sw i=•c'1- �U.1 .Y _ _ __ _..� . llxt iY" ti Mi AbAig25a.J. INSPECTION RECORD Retain a copy with permit INSPECTION NO. P RMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project��� 7� Type of Inspection: ! 6 .5- q�,/d%� l.�f/ ��/ r i u, Date Called: Special Instructions: Date Wanted:6 /, /7 a Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. OMMENTS: - SAR/ /��= Inspe f`Or: it t- 4yrfig /.i Date: //7/o, ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �.,...__. -... -..e, .._. r �....ar.1'.+.�s.�� _�. a ..&am, 2006 Washin• ton State Nonresidential Ener Code Corns Hance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 466 Southcenter Mall Date 2/12/2008 #1010 For Building De VO E \pt� CODE iCQ►{� NEPA 7C 1� sAAR 1 Tukwila, WA 98188 Applicant Name: Clarke Applicant Address: Applicant Phone: Project Description Sales Area • New Building • Addition 'i Alteration • Plans Induded Refer to WSEC Section 1513 for controls and commissioning requiremen Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysi B due (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on . Alteration Exceptions (check appropriate box - sec. 1132.3) 0.50 2787.0 • No changes are being made to the lighting Sales Area & space use not changed. • Less than 60% of the fixtures new, installed wattage not increased, Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per fr2 " Area in ft2 Allowed x Area Sales Area Retail 1.50 1290.0 1935.0 Sales Area Additional Retail Note #10 1.50 1290.0 1935.0 Back Room Storage Area - calculated with racking as shown on pl 0.50 2787.0 1393.5 From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt l 5263.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Back Room Type F - 2lourescent Strip Light 17 62.0 1054.0 Back Room Type G - Wraparound floureacent 1 62.0 62.0 Back Room Type BE - Recessed flourescent downlight - emergency 1 28.0 28.0 Sales Area Type BE - Recessed floureacent downlight - emergency 5 28.0 140.0 Sales Area Type B - Incandescent downlights 4 75.0 300.0 Sales Area Type A - Metal Halide pendant fixture 2 84.0 168.0 Sales Area Type n2 - Metal halide multi -spot fixture 4 88.0 352.0 Sales Area Type B - Metal halide downlight 21 30.0 630.0 Sales Area Type TH - Metal halide track head 80 30.0 2400.0 Back Room Type B - Metal halide downlight 1 30.0 30.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt sl 5164 .0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank_ r FILE COPY puoiCE - NEC 20N Tul�uila l C. -. .N FEB 1 9 2008 2006 Washin ton State Nonresidential Ener Code Come Hance Form Interior Lighting Summary (back) 2006 Washington State Nonresidential Energy Code Compliance Form LTG -INT Revised July 2007 Prescriptive Spaces Occupancy: rt Warehouses, storage areas or aircraft storage hangers Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space Is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 • Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballas 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA is Use' LPA (W /sf) Uses LPA2 (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals. institutions, museums, banks, churches) " 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments5, restaurants/bars5 1.3 Post office 1.1 Dormitory 1.0 Retail75, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only). school classrooms, day care centers 1.2 Gvmnasias. assembly spaces') 1.0 Theater. motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall's 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified 'laboratory' shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Librariess 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms. elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washin ton State Nonresidential Ener Code Com•liance Form • Lighting Power Allowance Adjustments 2008 Washington State Nonresidential Energy Code Compliance Forms LTG -LPA Revised July 2007 Project Address 1466 Southcenter Mall !Date 1/29/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances fo interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per2f1location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per f? ** Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per t? ** From Table 15 -1 based on exceptions listed in footnotes Li'jhting, 2008 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 466 Southcenter Mall (Date 2/12/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Requirec Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E100 yes 1513.2 Area controls Maximum limit per switch 8100 yea 1513.3 Daylight zone control Schedule with type and features, indicate locations 8100 yea vertical glazing Indicate vertical glazing on plans 8100 n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 5100 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations a. a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 IMax, watts 'Indicate watts for each exit sign 18400 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) U.S. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) yes I 1540 'Transformers 'Indicate size and efficiency 1E200 I If "no" is circled for any question, provide explanation: Li jhting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1613 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones. as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). PERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -158 DATE: 02 -19 -08 PROJECT NAME: CLARKS SITE ADDRESS: 466 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil �ng urvision Public Works Fire Prevention Structural Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 02-2 1 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: � Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03-20-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routmg slip.doc 2 -28-02 Look Up a Contractor, Electrii or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License MKELEKE957PO Licensee Name M K ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602543822 Ind. Ins. Account Id 10143400 Business Type CORPORATION Address 1 PO BOX 612 Address 2 City BUCKLEY County PIERCE State WA Zip 98321 Phone 3608295362 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 10/20/2005 Expiration Date 10/20/2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License OTIS *BC939L7 Electrical Administrator Information License OTIS *BC939L7 Name OTIS, BRIAN C Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FINNEY, MICHAEL F AGENT 10/20/2005 FINNEY, MICHAEL F PRESIDENT 10/20/2005 PEDERSEN, DOUGLAS • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= MKELEKE957P0 06/10/2008 CODES 2006 INTERNATIONAL BUILDING CODE W/ WASHINGTON AMENDMENTS 2006 INTERNATIONAL MECHANICAL CODE W/ WASHINGTON AMENDMENTS 2006 UNIFORM PLUMBING CODE W/ WASHINGTON AMENDMENTS 2006 INTERNATIONAL FIRE CODE W/ WASHINGTON AMENDMENTS 2006 WASHINGTON STATE ENERGY CODE 2005 NATIONAL ELECTRICAL CODE BUILDING DEPARTMENT CITY OF TUKWILA DEPARTMENT OF COMMUNITY DEVELOPMENT 6300 SOUTHCENTER BLVD. #100 TUKWILA, WA 98188 PH. 206 -431 -3670 CODE INFORMATION FULLY SPRINKLERED CONSTRUCTION TYPE: 2B OCCUPANCY CLASS: M GROSS SQUARE FOOTAGE NET SQUARE FOOTAGE FRONT OF HOUSE AREA = 1,270 SF (30 S.F./ OCCUPANT) BACK OF HOUSE AREA = 1,243 SF (300 S.F_ / OCCUPANT) TOTAL OCCUPANT LOAD NO. OF EMPLOYEES = 3 PERSONS 2,700 SF 2,521 SF 43 5 48 ENGINERING CONSULTANTS MECHANICAL POINT ONE DESIGN 9941 YORK THETA DRIVE NORTH ROYALTON, OH 44133 PH. 440 -230 -1800 FX. 440 -230 -1831 ELECTRICAL STADELMAN ASSOCIATES 931 PORTAGE TRAIL CUYAHOGA FALLS, OH 44221 PH. 330- 926 -2600 FX. 330 - 926 -4531 DEVELOPER WESTFIELD 11601 WILSHIRE BLVD. 14TH FLOOR LOS ANGELES, CA 90025 CONTACT: JOSH KIMMEL e -mail: JKIMMEL @WESTFIELD.COM PH:310- 893 -4761 OWNER CLARKS 156 OAK STREET NEWTON UPPER FALLS, MA 02464 BOB JOHNSON SENIOR DIRECTOR OF CONSTRUCTION PH. (617) 796 -5056 FX. (617) 243 -4210 DENNIS HORN DIRECTOR OF CONSTRUCTION PH_ (617) 243 -4214 FX. (617) 243-4210 WESTFIELD SOUTHCENTER 466 SOUTHCENTER MALL TUKWILA, WA 98188 STORE # 753 KEY PLAN i L 110' " fi LEASELINE TO LEASELINE Q 11' -3 GROSS LEASEABLE AREA 2,700 SQ. FT. i CLARKS LEVEL 1 OF 3 SPACE #1010 51' -sin VICINITY MAP WESTFIELD SOUTHCENTER 466 SOUTHCENTER MALL SPACE #1010 TUKWILA, WA 98188 SOUTHCENTER WESTFIELD SOUTHCENTER BAKER BLVD. STRANDER BLVD. LEASELINE TO LEASELINE LOD PLAN SCALE: 1/8"= f-0" REVISION: / ' 02 -13 -08 -PER LANDLORD COMMENTS -AKS REVISIONS No changes shall be made to the scope of work of Tukwila a B dinDivin NOM Revisions require a new plan submittal and may include additional plan review fees. REVIEWED PL1ANCE CODE CO NFPA 70 -- NEC City Of Tukwila ON $ `'LOIN OM . FILE COPY Permit Nos PJar review approval la too= and omissions. Apvat of conelnictlei documents does wit aulhodze the *Mon of any a dcodeor mamma, Ikseipt of wood - _ BY Date: d City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED MechanIcal CI Electrical OPiumbing Gas Piping City of Tukwila BUILO%NQ DIVISION 'Rf't'h2gkitti I'i At!w V.1.414 I' I '�' `J= {� Oto, MODIFIED OR ALTERED WITHOUT' AUTHORIZATION FROM THE BUILDING qffIHIiki• t ALI WORK SHALL BE DONE IN A@ OtiPkitt WITH THE APPROVE PLANS I5 3,ti" -` tt to FIELD INSPECTIONS ISSUE / DATE: Public works, Building Division PERMIT NUMBER OS:i INDEX OF DRAWINGS ARCHITECTURAL C100 COVER SHEET /INDEX/CODE INFO C101 GENERAL NOTES C102 FINISH SCHEDULE / RESPONSIBILITY SCHEDULE C103 MOULDING SCHEDULE/ PROFILES A100 FLOOR PLAN A101 ENLARGED TOILET PLAN / ELEVATIONS A102 EGRESS PLAN A200 REFLECTED CEILING PLAN A300 ENLARGED STOREFRONT PLAN/ ELEVATION A400 INTERIOR ELEVATIONS A401 INTERIOR ELEVATIONS A500 STOREFRONT SECTIONS A501 STOREFRONT DETAILS A502 STOREFRONT DETAILS A503 STOREFRONT DETAILS A600 INTERIOR DETAILS A700 DOOR SCHEDULE/ DETAILS/ NOTES A701 THRESHOLDS & FLOORING TRANSITIONS A800 A801 A802 A803 AS100 AS101 AS102 PLUMBING FIXTURE PLAN FIXTURES - DETAILS FIXTURES - DETAILS FIXTURES - DETAILS SPECIFICATIONS SPECIFICATIONS SPECIFICATIONS P100 PARTIAL PLUMBING PLAN / DETAILS P200 PLUMBING SPECIFCATIONS / SCHEDULE MECHANICAL M100 MECHANICAL PLAN M200 MECHANICAL SYMBOLS, NOTES & SCHEDULES ELECTRICAL E100 E200 E300 LIGHTING PLAN POWER PLAN ELECTRICAL DETAILS E400 ELECTRICAL SYMBOLS & NOTES/ LIGHTING FIXTURE SCHEDULE E500 POWER RISER DIAGRAM / PANEL SCHEDULES E600 ELECTRICAL SPECIFICATIONS ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 Cr— �a FEB 1 2C38 & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 FILE COPY tG% LEAVE TUG INCHES FOR DRYWALL INSTALLATION. Hbff e e 4 GANG BACKBOX. COMMON FACEPLATE nCn udu e e GIENSRAL DIBFLAY TRACK LIGWTMG LIGWTe LIGk4T8 u &n e TRA.= TRACK MATURE LIGHTS LIGWTS WALL IIfII 6 MACK LIGHTS J e e FINISHED FLOOR 48" 1 MASTER SWITCHPLATE DETAIL E100 SCALE NONE GENERAL NOTES: 1. THE ELECTRICAL CONTRACTOR SHALL BE HELD TO HAVE REVIEWED ALL SHEETS OF THESE CONTRACT DOCUMENTS INCLUDING ARCHITECTURAL, MECHANICAL, FIXTURE PLANS, ETC. & WILL BE RESPONSIBLE FOR PERFORMING ALL WORK INDICATED ON ANY SHEET. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THE WORK OF OTHERS 2. REFER TO SHEE A200 FOR DIMENSIONED LOCATION OF LIGHT FIXTURES IN THE REFLECTED CEILING PLAN. 3. REFER TO SHEE ► E600. OR NOTES & SPECIFICATIONS. 4. REFER TO SHEE E400 OR LIGHTING SCHEDULE, FLAG NOTES, SYMBOL LEGEND & DETAILS. 5. REFER TO SHEE E500 OR RISER DIAGRAM & PANEL SCHEDULES. 6. NIGHT LIGHTING FIXTURES WITHOUT EMERGENCY FEATURE SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUITS AHEAD OF ALL LOCAL SWITCHING. EC SHALL FURNISH AND INSTALL ADDITIONAL HOT WIRE IN BRANCH CIRCUIT TO ACCOMPLISH THIS. 7. ALL WIRING LINES INCLUDING LOW VOLTAGE IN THE CEILING PLENUM SHALL BE IN CONDUIT. 8. EXISTING EXTERIOR LIGHTING TO REMAIN BY LANDLORD CONTROL. NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge \, i FTCESJIEVVED FOR 4 :Pp 70 - NEC t 10 2* City Of Tukwila INC DIVISION CONNECTION TO SIGN T2 T4 T4 % T4 T4 LIGHTING PLAN SCALE: 1 /4 " =1' -0" "2\ FEB 1 9 Z003 & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 REVISION A02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : LIGHTING PLAN SHEET NO. : E100 FIRE ALARM JUNCTION 13OX SUPPLIED BY LANDLORD FURNISH AND INSTALL WIRING FOR POWER CIRCUIT. FURNISH AND INSTALL WIRING FOR COMMUNICATION CIRCUIT. TO ADDITIONAL DEVICES PROVIDE TIE IN AS REQUIRED TO MALL / MAIN BUILDING FIRE ALARM SYSTEM. COORDINATE EXACT REQUIREMENTS WITH LANDLORD PRIOR TO ROUGH N. FIRE ALARM WIRING NOTES: 1. TENANT SHALL BE REQUIRED TO INSTALL AN ADDRESSABLE FIRE ALARM SYSTEM PER LANDLORDS REQUIREMENTS. COORDINATE REQUIREMENTS AND INSTALLERS WITH LANDLORD PRIOR TO N5TALLATION. 2. LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR 15 10 BE DETERMINED. 3, tI-1I5 RISER REPRESENTS .4 TYPICAL SYSTEM AND 15 NoT INTENDED FOR NSTALLATIOt( SYSTEM SUPPLIER 51-IALL PROVIDE INSTALLATION DRAWINGS AND WIRING DIAGRAMS. EXACT SYSTEM REQUIREMENTS SHALL IBE COORDINATED WITH tHE SYSTEM SUPPLIER 4. SYSTEM SUPPLIER SMALL SUPERVI5E INSTALLATION, PROGRAM AND TEST SYSTEM, AND INSTRUCT OWNER ON SYSTEM OPERATION. 5_ ALL FIRE ALARM WIRING SHALL 13E IN 3/4" CONDUIT, MINIMUM. ALL WIRING SHALL BE VERIFIED WITI -4 THE SYSTEM SUPPLIER PRIOR TO PIP. 6. PROVIDE ADDITIONAL ADDRESSABLE MONITOR AND CONTROL MODULES AS RECOMMENDED BY tHE SYSTEM SUPPLIER 1. ALL CONTROL CABINET5 SHALL BE GROUNDED PER NEC. REQUIREMENTS AND PER SPECIFICATIONS_ 8. COORDINATE CITY TIE -IN REQUIREMENTS WITH LOCAL AUTHORITY. REFER TO DRAWING5 FOR DEVICE QUANTITY AND LOCATIONS. PROVIDE WIRING TO DEVICES INDICATED AS REQUIRED BY FIRE ALARM SYSTEM SUPPLIER INSTALLATION DRAWINGS. 10. FIRE ALARM SYSTEM SHALL COMPLY WITH THE ZONING REQUIREMENTS OF THE STATE BUILDING CODE AND THE NFPA. ALL INITIATING DEVICES INDIVIDUALLY REPORT TO THE FIRE ALARM CONTROL PANEL FOR SEPARATE ANNUNCIATION. FIRE ALARM SYSTEM RISER DIAGRAM NOT TO SCALE TYPICAL WIRING NOTE_ FUR 4151-1 AND INSTALL WIRING TO ALL SYSTEM DEVICES AS REQUIRED BY SYSTEM INSTALLATION DRAWINGS. REFER TO FIRE ALARM SYSTEM NOTES. 30KVA XFMR FLOOR MTD.) FIRE ALARM JUNCTION BOX SUPPLIED BY LANDLORD MAIN 200A DISCONNECT SWITCH PANEL HA PANEL LA TIM ECLOCK GENERAL NOTES: 1. THE ELECTRICAL CONTRACTOR SHALL BE HELD TO HAVE REVIEWED ALL SHEETS OF THESE CONTRACT DOCUMENTS INCLUDING ARCHITECTURAL, MECHANICAL, FIXTURE PLANS, ETC. & WILL BE RESPONSIBLE FOR PERFORMING ALL WORK INDICATED ON ANY SHEET. THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR COORDINATING THEIR WORK WITH THE WORK OF OTHERS. 2. REFER TO SHEE 3. REFER TO SHEE 4. REFER TO SHEE 5. REFER TO SHEE FOR DIMENSIONED LOCATION OF LIGHT FIXTURES IN THE REFLECTED CEILING PLAN. FOR NOTES & SPECIFICATIONS. FOR LIGHTING SCHEDULE, FLAG NOTES, SYMBOL LEGEND & DETAILS. OR RISER DIAGRAM & PANEL SCHEDULES. 6. NIGHT LIGHTING FIXTURES WITHOUT EMERGENCY FEATURE SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUITS AHEAD OF ALL LOCAL SWITCHING. EC SHALL FURNISH AND INSTALL ADDITIONAL HOT WIRE IN BRANCH CIRCUIT TO ACCOMPLISH THIS. 7. ALL WIRING LINES INCLUDING LOW VOLTAGE IN THE CEILING PLENUM SHALL BE IN CONDUIT. 8. EXISTING EXTERIOR LIGHTING TO REMAIN BY LANDLORD CONTROL. 9. PHONE JACKS, PHONE CABLE AND DATA CABLE ARE PROVIDED BY THE ELECTRICAL CONTRACTOR 10. OUTLETS IN SALES AREA ONLY TO BE MOUNTED 26" A.F.F. EMERGENCY CALL FOR AID AUDIOVISUAL DEVICE MOUNTED OVER DOOR "CORNELL" VS -110 \ i t LA 21 CALL FOR AID POWER SUPPLY IEI 'PIP24VDC ABOVE CEILING. REFER TO WIRING DIAGRAM ON TINS DRAWING. I I LA 111 SPARE I NDTE : UNIT EQUIPMENT SHALL BE AS SUPPLIED BY "TRI -S CONTROLS" (TOM ANSPACI -1) 330 - 220 -4400 yD EMERGENCY CALL FOR AID WIRING DIAGRAM POWER PLAN SCALE: 1/4"=11-0" r r FEB 19 [O>i3 F STAD ` WAS o yid?':. 'pc, 38194 cc, SS/O N AL Nc':; 1 EXPIRES cf 2.51`1 Ti & ASSOCIATES > Retail Design & Development 345 SPRINOSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 REVISION : 02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : POWER PLAN SHEET NO. : E200 O I�II� ACCESS PANELS (TYP. 8) O O 1 CASHWRAP OUTLET PLAN E300 SCALE: NONE A - COUPONS, CUSTOMER SERVICE FORMS, DESKTOP SUPPLIES B - BINDERS, PHONE BOOKS, ENVELOPES, BLANK PAPER C - POSTAL & CLEANING SUPPLIES. D - TAPE & STAPLER E - COUPONS AND DAILY NOTES TRANSACTION COUNTER UB_ E CUB. D TILTED MONITOR RE'CP`Ij PTR. KEYBOARD SC USE PHO NE E PLAN BOOT BAG O r-D SML BAG CASH DWR B ?RTR CPU CABLE ELEVATION 2 DETAIL- CASHWRAP POS LAYOUT E300 SCALE: 3/4" = 1' FURNISH AND INSTALL PHOTOELECTRIC DUCT MOUNTED SMOKE DETECTOR WITH AUXILIARY CONTACTS. WIRE TO SHUT DOWN FP5 UNIT UPON ACTIVATION. COORDINATE EXACT MOUNTING LOCATION WITH MC AND AUTHORITY HAVING JURISDICTION ON SITE. "FCI *DH100ACDCP PI- IOTOELECTRIC TYPE 4 -WIRE. LA C/B LOCK ON CLIP 1*15 AWG IN 1"C FURNISH AND INSTALL. SAMPLING TUBE. LENGTH TO BE SPECIFIED BY TI-IE MC_ RETURN 4 SUPPLY DUCTS CO n--- FURNISH AND INSTALL: FCI* SSK451 REMOTE TEST STATION WITW POWER ALARM AND TROUBLE LIGHT AND A BUZZER WHERE REQUIRED BY LOCAL AUTHORITY, ADD FCI *P524L0 FIRE STROBE LIGHT. DUAL GANG MOUNTED, 1 PLATE. I IC FURNISHED ,411../ 1 1 W 1!"14_ 41../ THERMOSTAT TYPICAL DUCT MOUNTED SMOKE DETECTOR 4 ALARM INDICATION WIRING DIAGRAM E300 SCALE: NONE NOTE: UNIT EQUIPMENT SHALL BE AS SUPPLIED BY "TRI -S CONTROLS" (GEORGE JARMUSIK) 330 - 220 -4400 OUTLET FOR r 15ACKROOM PHONE MAIN TELEPHONE NUMBER Ow- RJ11C 2'x4' PLYWOOD PHONE BOARD MOUNTED TO WALL IN BACKROOM /11 1 J 3 PAIR PHONE CABLE N CONDUIT TO CASHWRAP CAT. 5 CABLE TO CASHWRAP SPARE TWISTED PAIR SECOND TELEPHONE NUMBER TELEPHONE COMPANY PUNCH DOWN BLOCK ROM TELEPHONE COMPANY 3 TELEPHONE / ADT RISER DIAGRAM E300 SCALE: NONE '! A FEB 19 2003 L,1\ i Lza 1IJNI1NUI avi'1 & ASSOCIATES > Retail. Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 REVISION : 02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : ELECTRICAL DETAILS SHEET NO. : E300 ACCESS PANELS (TYP. 8) O O 1 CASHWRAP OUTLET PLAN E300 SCALE: NONE A - COUPONS, CUSTOMER SERVICE FORMS, DESKTOP SUPPLIES B - BINDERS, PHONE BOOKS, ENVELOPES, BLANK PAPER C - POSTAL & CLEANING SUPPLIES. D - TAPE & STAPLER E - COUPONS AND DAILY NOTES TRANSACTION COUNTER UB_ E CUB. D TILTED MONITOR RE'CP`Ij PTR. KEYBOARD SC USE PHO NE E PLAN BOOT BAG O r-D SML BAG CASH DWR B ?RTR CPU CABLE ELEVATION 2 DETAIL- CASHWRAP POS LAYOUT E300 SCALE: 3/4" = 1' FURNISH AND INSTALL PHOTOELECTRIC DUCT MOUNTED SMOKE DETECTOR WITH AUXILIARY CONTACTS. WIRE TO SHUT DOWN FP5 UNIT UPON ACTIVATION. COORDINATE EXACT MOUNTING LOCATION WITH MC AND AUTHORITY HAVING JURISDICTION ON SITE. "FCI *DH100ACDCP PI- IOTOELECTRIC TYPE 4 -WIRE. LA C/B LOCK ON CLIP 1*15 AWG IN 1"C FURNISH AND INSTALL. SAMPLING TUBE. LENGTH TO BE SPECIFIED BY TI-IE MC_ RETURN 4 SUPPLY DUCTS CO n--- FURNISH AND INSTALL: FCI* SSK451 REMOTE TEST STATION WITW POWER ALARM AND TROUBLE LIGHT AND A BUZZER WHERE REQUIRED BY LOCAL AUTHORITY, ADD FCI *P524L0 FIRE STROBE LIGHT. DUAL GANG MOUNTED, 1 PLATE. I IC FURNISHED ,411../ 1 1 W 1!"14_ 41../ THERMOSTAT TYPICAL DUCT MOUNTED SMOKE DETECTOR 4 ALARM INDICATION WIRING DIAGRAM E300 SCALE: NONE NOTE: UNIT EQUIPMENT SHALL BE AS SUPPLIED BY "TRI -S CONTROLS" (GEORGE JARMUSIK) 330 - 220 -4400 OUTLET FOR r 15ACKROOM PHONE MAIN TELEPHONE NUMBER Ow- RJ11C 2'x4' PLYWOOD PHONE BOARD MOUNTED TO WALL IN BACKROOM /11 1 J 3 PAIR PHONE CABLE N CONDUIT TO CASHWRAP CAT. 5 CABLE TO CASHWRAP SPARE TWISTED PAIR SECOND TELEPHONE NUMBER TELEPHONE COMPANY PUNCH DOWN BLOCK ROM TELEPHONE COMPANY 3 TELEPHONE / ADT RISER DIAGRAM E300 SCALE: NONE '! A FEB 19 2003 L,1\ i Lza 1IJNI1NUI avi'1 & ASSOCIATES > Retail. Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 REVISION : 02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : ELECTRICAL DETAILS SHEET NO. : E300 FLAG NOTES SAW CUT AND REPAIR FLOOR FOR CONDUIT INSTALLATION. EXERCISE EXTREME CARE AND CAUTION. IF LEASED SPACE IS NOT SLAB ON GRADE THEN SLAB MUST BE CORE DRILLED IN ACCORDANCE WITH LANDLORD REQUIREMENTS. ALL CUTTING MUST BE APPROVED BY LANDLORD'S REPRESENTATIVE PRIOR TO ROUGH IN. RECEPTACLE OUTLET SHALL BE INSTALLED DIRECTLY ABOVE SHOW WINDOW FOR EACH 12 FT OR MAJOR FRACTION THEREOF OF SHOW WINDOW AREA MEASURED HORIZONTALLY AT ITS MAXIMUM WIDTH. 3/4" CONDUIT BACK TO PHONE BOARD FOR TELEPHONE CABLING. FURNISH AND INSTALL PULLWIRE. MOUNT RECEPTACLES, TELEPHONE JACKS & SPEAKER WIRES IN CASH WRAP MILLWORK BELOW COUNTER. REFER TO CASHWRAP DETAILS & NOTES. ALL WIRING TO "TTB" SHALL BE IN CONDUIT. 3/4" CONDUIT BACK TO PHONE BOARD FOR DATA CABLING. FURNISH AND INSTALL PULLWIRE. EMERGENCY FIXTURES WHICH ARE NOT INDICATED AS NIGHT LIGHTS SHALL BE SWITCHED AS INDICATED. BATTERY TO BE WIRED HOT AHEAD OF SWITCH AS REQUIRED BY MFGR. FURNISH AND INSTALL ADDITIONAL HOT WIRE AS REQUIRED. DOOR BELL SYSTEM. REFER TO ELECTRICAL SYMBOL LEGEND. "TTB" (TELEPHONE TERMINAL BOARD)- FURNISH AND INSTALL PLYWOOD BACKBOARD 3/4 "X2'X4' MOUNTED AT 6' -O" AFF TO CENTERLINE. FURNISH AND INSTALL #8 AWG CU TO SERVICE ENTRANCE GROUND TERMINATED ON GROUND BAR LOCATED AT BOTTOM OF "TTB "_ PROVIDE A 4 "x4 "x2 1/8" OUTLET BOX ON TTB FOR TERMINATION OF TELEPHONE WIRING FROM CASH WRAP. INSTA HOT UNIT UNDER SINK, 4.6KW, 208V-lph FURNISHED AND INSTALLED BY OTHERS, WIRED BY EC. FURNISH AND INSTALL DISCONNECT SWITCH IF REQUIRED BY EQUIPMENT LITERATURE. EC TO PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANTS TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZINGTHE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. TENANT SOUND SYSTEM TO BE INSTALLED BY MUZAK. G.C. TO COORDINATE WIRE TO LOCAL LIGHTING CIRCUIT AHEAD OF ALL LOCAL SWITCHING. WIRE THROUGH SWITCH AS REPRESENTED IN THE "MASTER SWITCHPLATE" WITH CORRESPONDING LOWER CASE LETTER. WIRE THROUGH TIME CLOCK AND LIGHTING CONTACTOR LOCATED IN BACK ROOM. REFER TO POWER RISER DIAGRAM HVAC UNIT DUCT SMOKE DETECTOR SHALL SHUT DOWN HVAC UNIT (COORDINATE LOCATION AND WIRING WITH HVAC CONTRACTOR). LOCATION OF MASTER SWITCHPLATE. CONNECTION TO SIGN OVER DOOR. COORDINATE EXACT WIRING REQUIREMENTS WITH SIGN MANUFACTURER PRIOR TO ROUGH IN. CONNECTION TO "FEATURE WALL" SHALL BE COORDINATED ON SITE WITH MANUFACTURER. FEATURE WALL CONSISTS OF T8 LAMPS ARRANGED AS REQUIRED BY MANUFACTURER. TOTAL FIXTURE WATTAGE ASSUMED TO BE NOT OVER 300 WATTS. TIME DELAY SWITCH FOR CONTROL OF RESTROOM LIGHT AND EXHAUST FAN, GREENHECK "GTD" TIME DELAY SWITCH, OR APPROVED EQUAL. EC SHALL SET TIME DELAY FOR FIVE MINUTES. NOTE: N/A = NOT APPLICABLE TO THIS PROJECT. LIGHTING SCHEDULE SYMBOL LEGEND TYPE DESCRIPTION CATALOG # LAMP FIXTURE LOCATION /NOTES IUTAL WATTS QTY. 0�� ♦s! A LUMASTAR EB SERIES 16" ZENOS DIRECT /INDIRECT ACRYLIC LUMINAIRE ELECTRONIC BALLAST, CLEAR ACRYLIC. EB- A -Z -C- 70ED17- 24WHT 70 (ED17) 120 VOLT MOUNTED IN SALES AREA : IF 11' -0" CEILING -TO BE CEILING MOUNTED. IF 12' -0" - 13' -O" CEILING MOUNT AT 10' -0" TO BOTTOM OF FIXTURE 70 2 0 B 7" ADJUSTABLE INCANDESCENT PAR 38 RECESSED DOWNLIGHT WITH CLEAR ALZA RELECTOR SPA7X -PAR38 - 25- 45 -TBC- AR7500CL CDM -125w/ 830/PAR38/10 SPOT MOUNTS RECESSED IN ACT. CLG. TILES IN MAIN SALES AREA. PROVIDE HANG BARS AND CLIPS 25 BE LIGHTOLIER CALCULITE COMPACT FLUORESCENT OPEN RECESSED DOWNLIGHT WITH CLEAR IRIDESCENCE FREE REFLECTOR TRIM, WHITE FLANGE. 8" APERTURE (2) TRIPLE TUBE HORIZONTAL LAMP, BATTERY BACK UP AND TEST SWITCH 8038 -CLW- 8242HU- FA EM4E (2) 26W TRIPLE TUBE MOUNTS RECESSED IN ACT. CLG. TILES IN MAIN SALES AREA. PROVIDE HANG BARS AND CLIPS- WIRED AS EMERGENCY LIGHT FIXTURE 54 SDOOR B 6 e C LIGHTOLIER LYTECASTER RECESSED DOWNLIGHTING. 5" APERATURE RECESSED ADJUSTABLE REFLECTOR TRIM - WHITE 1029WH 75W PAR30 MOUNTS RECESSED IN MAIN SALES AREA AROUND CASH WRAP 75 0 JUNO MULTI -SPOT RECESSED ADJUSTABLES WHITE CLOSED -PAN TRIM APPEARANCE. 45 DEGREE AIMING 360 DEGREE ROTATION AND HANGER BARS MS303- 70- EMH -WH, HB26 (3) CDM70 PAR3OL/FL MOUNTS RECESSED IN GYP. BD. SOFFIT AT DISPLAY WINDOWS 210 0 O O O D1 la F JUNO MULTI -SPOT RECESSED ADJUSTABLES WHITE CLOSED -PAN TRIM APPEARANCE. 45 DEGREE AIMING 360 DEGREE ROTATION AND HANGER BARS MS302- 39- EMH -WH HB26 (2) 39W- MHPAR3OUFL MOUNTS RECESSED IN GYP. BD. SOFFIT AT DISPLAY WINDOWS 88 4 0.0 D2 0 E TECH LIGHTING EMERGE PENDANT - COLOR:TAHOE PINE AMBER TT -A (1) 120 VOLT, 75 WATT MEDIUM BASE -A 19 SUSPENDED IN SALES AREA IN OVER CASH WRAP @ T -0" TO BOTTOM OF FIXTURE 75 4 DD F MERCURY LIGHTING PRODUCTS SURFACE MOUNTED MULTI LAMP FLUORESCENT CHANNELS. 2 LAMP 4' MM- 2- 32 -OCT/ 4T- C- ELB -120V (2) F32T8/ TL830 /ALTO SURFACE MOUNTS TO ACOUSTIC TILE CEILING IN BACK ROOM 65 UNO U F N.L. N COLUMBIA SURFACE MOUNT 2 -LAMP 4' PROFILE WRAPAROUND - WHITE FINISH WITH PRISMATIC ACRYLIC DIFFUSER AWN4 -240 EB8- 120 -EL (2) F32T8/ TL830 /ALTO SURFACE MOUNTS TO GYP. BD. CEILING IN TOILET ROOM. 65 1 G & TH LIGHTOLIER LYTESPAN TRACK LIGHTING SYSTEM 22SS8BK ALCYON ENCLOSED STEP SPOT PAR38 22SS8BK CDM -i25w/ 830/PAR38/10 SPOT SURFACE MOUNTED IN SALES AREA 25 80 LIGHTOLIER BASIC LYTESPAN 1 CIRCUIT TRACK 6000 SERIES BLACK (2', 4', AND 8' TRACK) 6000BK (2') 6001 BK (4') 6002BK (8') BLACK 1 CIRCUIT 120V SURFACE MOUNTED IN SALES AREA. - 2' = 4 4' - 10 T# COOPER LIGHTING SURE -LITES SURFACE MOUNTED SELF - POWERED EMERGENCY LIGHTING UNIT CC2 INCANDESCENT SURFACE MOUNTED IN BACK ROOM WALL, 12" BELOW FINISH CEILING. 18 5 EM x ® 6 X1 X1 • LIGHTALARMS, SERIES SIMPLICITY, UNIVERSAL RECESSED MOUNT, SELF POWERED LED EDGE -LIT EXIT SIGN SLEDWGCD LED RECESS WALL /CEILING MOUNT IN SALES AREA- MOUNT 12" ABOVE DOOR JAMB FOR WALL MOUNTED CONDITIONS 3 1 0 X2 X2 SURFACE WALL / CEILING MOUNTED SINGLE OR DUAL FACE EXIT LIGHT WITH TEST SWITCH AND POWER INDICATOR LIGHT. BP- PLED -5G LED SURFACE MOUNT TO WALUCEILING IN BACK ROOM- MOUNT 12" ABOVE DOOR HEAD FOR WALL MOUNTED CONDITIONS 5 3 LIGHTING SCHEDULE NOTES 1. ELECTRICAL CONTRACTOR SHALL VERIFY QUANTITIES OF FIXTURES & LAMPS ON LIGHTING & POWER PLAN. 2. ALL FIXTURES SHALL BE FURNISHED BY OWNER, INSTALLED & WIRED BY CONTRACTOR 3. ALL SPEAKER COVERS, CLEANOUTS, PLATES, ETC. IN SALES AREA SHALL BE FINISHED TO MATCH ADJACENT SURFACES UNLESS OTHERWISE NOTED. 4. SOFFIT DIMENSIONS ARE FINISH TO FINISH. 5. INTERIOR FINISHES ON WALLS AND CEILING SHALL BE CLASS B AT A MINIMUM 6. COMBUSTIBLE MATERIAL IS NOT TO BE USED IN AREAS IN WHICH PLENUM RETURN AIR SYSTEMS ARE USED. 7. FIXTURE SHALL BE PRE -WIRED FROM THE FACTORY FOR SWITCHED OPERATION. EMERGENCY BATTERY PACK SHALL OPERATE IN EMERGENCY MODE ONLY. 8. LIGHTING SUPPLIER TO VERIFY LIGHT QUANTITIES AGAINST ARCHITECTS COUNTS SYMBOL DESCRIPTION NEUT. HOT EQUIP. GROUND HOMERUN TO PANEL "LA" INDICATING CIRCUIT NUMBERS - ALL WIRING SHALL BE 3 #12 WITH GROUND WIRE UON (INCREASE TO #10 FOR CIRCUITS BETWEEN 100 1 AND 200 LF) CONSULT ENGINEER FOR RUNS OVER 200 LIN FEET IF WIRE SIZE IS NOT INDICATED - ALL HOMERUNS SHALL BE TO A 20 AMPERE, 1 POLE CIRCUIT LA BREAKER UON. WHERE WIRE FILL IS NOT SHOWN, FURNISH AND INSTALL 2 #12, 1#12G, 3/4 "C It $ M SWITCH, SINGLE POLE, 20A, 120/277V ,3 S SWITCH, THREE -WAY, 20A, 120/277V MOUNTING - 48" A.F.F., CATALOG NO. HUBBELL, 1223 SERIES. M S SPST, 20A, MANUAL MOTOR STARTER, HP RATED WITH THERMAL OVERLOAD MOUNTING - AS REQUIRED. 0 J JUNCTION BOX, MOUNTING HEIGHT AND SIZE AS REQUIRED OR AS NOTED ON PLANS. Q D DUPLEX RECEPTACLE, GROUNDING TYPE, 20A, 125V, 3 WIRE, NEMA 6 -20R MOUNTING - 15" A.F.F. (26" A.F.F. IN SALES). CATALOG NO. HUBBELL 5262 SERIES (UNO). (174) D DOUBLE DUPLEX RECEPTACLE, GROUNDING TYPE, 20A, 125V, 3 WIRE, NEMA 6 -20R MOUNTING - AS NOTED ON PLANS, CATALOG NO. HUBBELL, 2 -5262 SERIES. DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER, 20A, 125V, 3 WIRE, NEMA 6 -20R MOUNTING - PER DETAIL, CATALOG NO. HUBBELL GF -5262 SERIES. p C CLOCK HANGER TYPE RECEPTACKLE BY PASS & SEYMOUR #S3713 -W OR EQUAL. MOUT AT 6' -0" AFF V D DESK PHONE OUTLET. MOUNTING - 18" AFF V P DESK DATA OUTLET. MOUNTING - 18" AFF. MAY BE IN THE SAME OUTLET BOX AS THE ELECTRICAL PANEL - IDENTIFICATION NUMBER AS NOTED. REFER TO DISTRIBUTION DIAGRAM AND PANEL SCHEDULE. MOUNTING - TOP 6 -0" A.F.F. ® E Ell ( DISCONNECT SWITCH: HEAVY DUTY, NEMA 1 UNLESS NOTED AS "WP" FOR WEATHERPROOF SDOOR B BELL - 24V, AC VIBRATING TYPE, MOUNTING - 7'-0" A.F.F, CATALOG NO. EDWARDS 340 -4G5. DOOR BELL PUSH BUTTON MOUNTING - 48" A.F.F., CATALOG NO. EDWARDS 852. • D SIGNAL TRANSFORMER, 20VA, 120V PRIMARY, 24V SECONDARY MOUNTING - ABOVE CEILING UNO, CATALOG NO. EDWARDS 592. III FIRE ALARM PULL STATION MOUNTED AT 48" AFF UON la F L F FIRE ALARM HORN WITH STROBE LIGHT - WALL MOUNTED AT 80" AFF UON W FIRE ALARM STROBE LIGHT - WALL MOUNTED AT 80" AFF UON F L F /s F FIRE ALARM SMOKE DETECTOR - CEILING MOUNTED DD F FIRE ALARM DUCT SMOKE DETECTOR - WITH REMOTE TEST STATION - COORDINATE DUCT MOUNTING WITH THE MC Ho F FIRE ALARM RATE OF RISE HEAT DETECTOR - CEILING MOUNTED WP W REVITCv D O UNO U UNLESS NOTED mtkR Z) ZI;a N.L. N NIGHT LIGHT Of TukV�.11�a Cl .- .. -r"h.I TTB T TELEPHONE TERMINAL BOARD B' LOIN .- Iv : 7 Cir' FEB 19 ZOG3 FEoa.,js i aR IA & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON. OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 REVISION : A02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : ELECTRICAL SYMBOLS / NOTES / DETAILS / LIGHTING SCHEDULE SHEET NO. : E400 EXISTING 200A DISCONNECT SWITCH FURNISHED AND INSTALLED BY LANDLORD. EC SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATE SHALL BE 1/8" THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED NDLORD PROVIDED METERING EQUIPMENT LANDLORD SPACE LANDLORD'S EXISTING ELECTRICAL DISTRIBUTION EQUIPMENT TO REMAIN I 200A EXISTING TO REMAIN 4 #3/0, 1#6G, IN LANDLORD - PROVIDED 3 "C. V PANEL NAME: HA LOAD SUMMARY PHASE BREAKDOWN LEGEND MOUNTING: SURFACE LOAD KWC AMPS D.F. KWD AMPS TOTAL PANEL LTG = LIGHTING VOLTAGE: 480/277V- 3ph-4W LTG 6.88 1.25 8.60 KWC PHASE A: 9.73 REC = RECEPTACLES BUS RATING: 225A REC 4.02 N.E.C. 4.02 KWC PHASE B. 7.48 AC = AIR CONDITIONING MAIN: 200A MAIN CIRCUIT BREAKER AC 9.03 1.00 9.03 KWC PHASE C: 9.08 W. HTR = WATER HEATER A.I.C. 14,000 AIC W. HTR. 4.16 1.00 4.16 MISC. = MISCELLANEOUS ETR OR NEW: NEW MISC. 2.20 1.00 2 -20 D.F. = DEMAND FACTOR PANEL NOTES: TOTAL 26.29 32 28.01 34 I N.E.C. = NATIONAL ELECT- CODE MINIMUM SERVICE SIZE 34 CCT NOTES DESCRIPTION LTG REC AC W.HTR. MISC C/B PHASE CB DESCRIPTION LTG REC AC W.HTR. MISC NOTES CCT 1 FPB-1 (HEATER) 2-66 0.90 20/3 HACR A 60/3 PANEL LA 1.82 0.72 0.00 2.08 1.40 A 2 3 2 DUCT SMOKE DETECTOR 2.66 B 2.27 2.10 0.00 0.00 0.45 4 5 B 4 2.66 BACKROOM LIGHTING / EF C 2.79 1.20 0.00 2.08 0.35 C 6 7 0.63 FPB -1 (FAN) 1-05 C _ 20/1 A TTB SPACE 0.20 20 /1 A 8 9 0.57 SPACE D 8 9 B FRAME RELAY AND ALARM SPACE 0.40 20/1 B 10 11 0.57 SPACE E 10 11 C CASH WRAP SPACE 0.30 20/1 C 12 13 0.63 SPACE F 12 13 A CASH WRAP SPACE 0.30 20/1 A 14 15 0.30 SPACE G 14 B SPACE 16 17 SPACE 15 C DESK SPACE 0.36 20/1 B 18 19 1.23 SPACE 1 16 17 A SPACE 2.08 C 20 21 0.35 SPACE 1 18 B INSTA HOT SPACE 30/2 22 23 SPACE 19 C SPACE 2 -08 A 20/1 SALES AREA RECEPTACLES 24 25 SPACE 20 21 SHOW WINDOW RECEPTACLES A 1.20 SPACE 20/1 B 20/1 BACKROOM RECEPTACLES 26 27 SPACE 22 23 SHOW WINDOW RECEPTACLES B 1.20 SPACE 20/1 C 20/1 SPARE 28 29 SPACE 24 25 BACKROOM RECEPTACLES C 0 -18 SPACE 20/1 A 2011 SPARE 30 TOTALS: 0.00 0.00 9.03 0.00 0.00 BACKROOM RECEPTACLES 0.36 6.88 4.02 0.00 4.16 2.20 TOTALS: PANEL NAME: LA LOAD SUMMARY PHASE BREAKDOWN LEGEND MOUNTING: SURFACE LOAD KWC AMPS D.F. KWD AMPS TOTAL PANEL LTG = LIGHTING VOLTAGE: 208Y /120V- 3ph-4W LTG 6 -88 t25 8.60 KWC PHASE A: 6 -02 REC = RECEPTACLES BUS RATING: 100A REC 4.02 N.E.C. 4.02 KWC PHASE B: 4.82 AC = AIR CONDITIONING MAIN: 100 A MAIN CIRCUIT BREAKER AC 0.00 1.00 (100 KWC PHASE C: 6.42 W. HTR = WATER HEATER AI_C. 10,000 W. HTR. 4.16 1.00 4.16 MISC. = MISCELLANEOUS ETR OR NEW: NEW MISC. 2.20 1.00 2.20 D.F. = DEMAND FACTOR PANEL NOTES: TOTAL 17.26 47 -94 18.98 52 -72 N.E.C. = NATIONAL ELECT. CODE MINIMUM SERVICE SIZE CCT NOTES DESCRIPTION LTG REC AC W.HTR. MISC C/B PHASE C/B DESCRIPTION LTG REC AC W.HTR. MISC NOTES CCT 1 ELECTRIC WATER COOLER 0.90 20/1 A 20/1 GENERAL AND EMERGENCY 0 -95 A 2 3 2 DUCT SMOKE DETECTOR 0 -05 20/1 B 20/1 DISPLAY LIGHTING 0.47 B 4 5 BACKROOM LIGHTING / EF 1 -18 0.05 20/1 C 20/1 TRACK LIGHTING 0.63 C 6 7 2 TTB 0.20 20 /1 A 20/1 TRACK LIGHTING 0.57 D 8 9 2 FRAME RELAY AND ALARM 0.40 20/1 B 20/1 TRACK LIGHTING 0.57 E 10 11 CASH WRAP 0.30 20/1 C 20/1 TRACK LIGHTING 0.63 F 12 13 CASH WRAP 0.30 20/1 A 20/1 FEATURE WALLS 0.30 G 14 15 DESK 0.36 20/1 B 20/1 SIGN 1.23 1 16 17 2.08 C 20/1 SHOW WINDOW LIGHTING 0.35 1 18 INSTA HOT 30/2 19 2 -08 A 20/1 SALES AREA RECEPTACLES 0.54 20 21 SHOW WINDOW RECEPTACLES 1.20 20/1 B 20/1 BACKROOM RECEPTACLES 0.18 22 23 SHOW WINDOW RECEPTACLES 1.20 20/1 C 20/1 SPARE 24 25 BACKROOM RECEPTACLES 0 -18 20/1 A 2011 SPARE 26 27 BACKROOM RECEPTACLES 0.36 20/1 B 20/1 SPARE 28 29 SPARE 20 /1 C 20/1 SPARE 30 TOTALS: 1.18 3 -30 0 -00 4-16 2 -20 5.70 0.72 0.00 0.00 0 -00 TOTALS: TENANT SPACE EC SHALL RELOCATE EXISTING 200A FUSED DISCONNECT SWITCH. 1 200A NEW 4 #3 /O, 1#6G, 3 "C BY EC. NEW 3 #12, 1#12G, 3/4 "C BY EC. FPB -1 480V /3PH 8KW HEATER 277V/1PH 1 /2HP FAN MOTOR 3.8FLA P NEW 4 #3 /O, 1#6G, 3 "C BY EC. NEW JUNCTION BOX BY EC 200A MCB 20/3 20/1 60/3 eTh NEW PANEL 'HA' 480/277V, 3P H (BY EC) 'I POWER RISER DIAGRAM A500 SCALE: NONE PANEL SCHEDULE NOTES: 1. ROUTE POWER THROUGH TIME CLOCK 2. CIRCUIT BREAKER SHALL HAVE LOCK ON CIRCUIT BREAKER CLIP. A,B,C,D, ETC = SWITCHES AS INDICATED ON LIGHTING FLOOR PLAN. TIMER NOTE: SET TIMER FOR STOREFRONT SIGNAGE AND LIGHTING PER THE MALL'S OPERATING HOURS 120V - CONTROL •--II • NEUTRAL LOAD LOAD r NEW 2 #12, 1#12G, 3/4 "C BY EC. 480V PRIMARY NEW 3 #6, 1#10G, 3/4 "C BY EC NEW 30KVA XFMR (FLOOR MTD.) BY EC - NEW 4 #3, 1#8G, 1-1/4"C BY EC. 208Y/120V SECONDARY NEW BY EC #6 AWG CONTINUOUS COPPER GROUNDING CONDUCTOR AND BOND TO THE NEAREST OF EITHER EFFECTIVELY - GROUNDED BUILDING STEEL OR COLD WATER PIPE WITHIN 5' -O" FROM POINT OF ENTRANCE INTO THE BUILDING TO REMAIN. TIME CLOCK: 120V CONTROL, 40 AMP CONTACTS, NEMA 1 ENCLOSURE, 24HR: SAME ON /OFF TIME EACH DAY, WITH RESERVE POWER. FURNISH AND INSTALL THE FOLLOWING TIME CLOCK DEPENDING ON THE NEED DEPICTED; TORK # W300L: UP TO 3 CIRCUITS 100A MCB NEW PANEL 'LA' 208/120V, 3PH (BY EC) _. REVI.E\N ED FOR CODE COMPLIANCE EC NFPA Oty Of Tuoila FEB 19 2013 w 0 x w & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666-6767 AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01 -30 -2008 REVISION : 02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : PANEL SCHEDULE / POWER RISER DIAGRAM SHEET NO. : E500 ExPri�ES t� v SECTION 16010 - ELECTRICAL GENERAL PROVISIONS 1. THE PROVISIONS OF THE INSTRUCTIONS TO BIDDERS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, ALTERNATES, ADDENDAS AND DIVISION 1 ARE A PART OF THIS SPECIFICATION. ELECTRICAL, ARCHITECTURAL, MECHANICAL AND ALL OTHER DRAWINGS AS WELL AS THE SPECIFICATIONS FOR ALL THE DIVISIONS ARE A PART OF THE CONTRACT DOCUMENTS. 2. VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH THE CONDITIONS AFFECTING THE INSTALLATION. SUBMISSION OF A PROPOSAL SHALL PRESUPPOSE KNOWLEDGE OF SUCH CONDITIONS AND NO ADDITIONAL COMPENSATION SHALL BE ALLOWED WHERE EXTRA LABOR OR MATERIALS ARE REQUIRED BECAUSE OF IGNORANCE OF THESE CONDITIONS. 3. DEFINITIONS: A. "CONTRACTOR" AS USED WITHIN THE CONTEXT OF THE ELECTRICAL CONTRACT DOCUMENTS SHALL EXPLICITLY REFER TO THE "ELECTRICAL CONTRACTOR ". B. THE TERM "FURNISH" SHALL MEAN TO SUPPLY AND DELIVERY TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS. C. THE TERM "INSTALL" SHALL MEAN WORK WHICH INCLUDES THE ACTUAL UNLOADING, UNPACKING, ASSEMBLY, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS. D. THE TERM "PROVIDE" SHALL MEAN TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE. 4. INCLUDE ALL LABOR, MATERIAL, EQUIPMENT, SERVICES AND PERMITS NECESSARY FOR THE PROPER COMPLETION OF ALL ELECTRICAL WORK SHOWN. ITEMS OMITTED, BUT NECESSARY, TO MAKE THE ELECTRICAL SYSTEM COMPLETE AND WORKABLE SHALL BE UNDERSTOOD TO FORM PART OF THE WORK. 5. IT IS THE PURPOSE OF THE ELECTRICAL DRAWINGS TO INDICATE THE APPROXIMATE LOCATION OF ALL EQUIPMENT, OUTLETS, ETC. ASCERTAIN EXACT LOCATIONS AND ARRANGE WORK ACCORDINGLY. THE RIGHT IS RESERVED TO EFFECT REASONABLE CHANGES IN THE LOCATION OF OUTLETS UP TO THE TIME OF ROUGHING -IN, WITHOUT ADDITIONAL COST TO THE OWNER. 6. TEMPERATURE AND INTERLOCK CONTROLS ARE PROVIDED AND WIRED BY A CONTROLS CONTRACTOR. UNE (120 VOLT) VOLTAGE CONTROL DEVICES, SUCH AS THERMOSTATS AND AQUASTATS, WHICH CONTROL FRACTIONAL HORSEPOWER, 120 VOLT MOTORS ARE FURNISHED BY MECHANICAL CONTRACTOR, AND ARE WIRED BY ELECTRICAL CONTRACTOR. 7. SECURE AND PAY FOR PERMITS AND INSPECTIONS REQUIRED FOR THE ELECTRICAL WORK. 8. WORK SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE PROVISIONS OF LOCAL AND STATE CODES, AS WELL AS THE NATIONAL ELECTRICAL CODE, AS INTERPRETED BY THE LOCAL AUTHORITY HAVING JURISDICTION. 9. CONSULT THE DRAWINGS, PRODUCT DATA AND SHOP DRAWINGS COVERING THE WORK FOR VARIOUS OTHER TRADES, THE FIELD LAYOUTS OF THE CONTRACTORS FOR THE TRADE AND MAKE ADJUSTMENTS ACCORDINGLY IN LAYING OUT THE ELECTRICAL WORK. 10. WARRANT THAT EQUIPMENT AND ALL WORK IS INSTALLED IN ACCORDANCE WITH GOOD ENGINEERING PRACTICE AND THAT ALL EQUIPMENT WILL MEET THE REQUIREMENTS SPECIFIED. GUARANTEE AGAINST DEFECTS IN WORKMANSHIP AND MATERIALS; REPAIR OR REPLACE ANY DEFECTIVE WORK, MATERIAL OR EQUIPMENT WITHIN ONE YEAR FROM DATE OF ACCEPTANCE. 11. THE EXISTING ELECTRICAL AND TELEPHONE SERVICE, AND ALL EXISTING COMMUNICATION SYSTEMS WITHIN THE BUILDING SHALL BE MAINTAINED THROUGHOUT THE CONSTRUCTION PERIOD. ANY SERVICE SHUTDOWNS THAT MAY BE REQUIRED SHALL BE SCHEDULED THROUGH THE OWNER AND SHALL BE DONE AT A TIME AS DIRECTED BY THE OWNER. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED FOR THESE SHUTDOWN PERIODS EVEN THOUGH PREMIUM-TIME WORK MAY BE REQUIRED. PROVIDE TEMPORARY SERVICE TO EQUIPMENT OR SYSTEMS THAT CANNOT BE SHUTDOWN, AS DETERMINED BY OWNER. 12. PROVIDE A MINIMUM OF ONE WEEK'S NOTICE TO THE OWNER BEFORE ANY SERVICE SHUTDOWN IS SCHEDULED. 13. BIDS SHALL BE BASED UPON THE SPECIFIED PRODUCTS OR LISTED ALTERNATIVES. THE DRAWINGS AND SPECIFICATIONS ARE BASED ON THE PRODUCTS SPECIFIED BY TYPE, MODEL AND SIZE AND THUS ESTABLISH MINIMUM QUAUTIES WHICH SUBSTITUTES MUST MEET TO QUAUFY FOR REVIEW. WHERE ONLY ONE MAKE IS NAMED, IT SHALL BE PROVIDED. VERBAL REQUESTS OR APPROVALS SHALL NOT BE BINDING ON THE ARCHITECT, ENGINEER OR OWNER. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS AND EQUIPMENT OTHER THAN THOSE SPECIFIED, HE SHALL SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS TO THE ARCHITECT AT THE BID OPENING. INDICATE ANY ADDITIONS OR DEDUCTIONS TO THE CONTRACT PRICE ON THE BID FORM. 14. EQUIPMENT AND MATERIALS USED ON THIS PROJECT SHALL BE NEW AND U.L. LABELED FOR THE APPLICATION. 15. THE CONTRACTOR SHALL KEEP ONE COMPLETE SET OF THE CONTRACT WORKING DRAWINGS ON THE PROJECT SITE ON WHICH HE SHALL RECORD ANY DEVIATIONS OR CHANGES FROM SUCH CONTRACT DRAWINGS MADE DURING CONSTRUCTION. AFTER THE PROJECT IS COMPLETED, RECORD SETS OF DRAWINGS SHALL BE DELIVERED TO THE ARCHITECT IN GOOD CONDITION, AS A PERMANENT RECORD OF THE INSTALLATION AS CONSTRUCTED. 16. PROVIDE NAMEPLATES ON PANELBOARDS, DISTRIBUTION EQUIPMENT, SAFETY SWITCHES, MOTOR STARTERS, JUNCTION BOXES, AND CONTROL DEVICES. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, LETTERING SHALL INCLUDE THE NAME OR DESIGNATION OF EQUIPMENT, HORSEPOWER, VOLTAGE RATING AND SERVICE DESIGNATION. NAMEPLATES SHALL BE LAMINATED PHENOUC WITH A BLACK SURFACE AND WHITE CORE. IDENTIFICATION WITH A DYMO TYPE INSTRUMENT IS NOT PERMISSIBLE. THE INSIDE COVER OF ALL RECEPTACLE OUTLET PLATES SHALL BE PERMANENTLY MARKED TO INDICATE THE PANEL AND CIRCUIT NUMBER OF THE OUTLET. THE INSIDE COVER OF ALL BLANK PLATES FOR JUNCTION BOXES INSTALLED SHALL BE PERMANENTLY MARKED TO INDICATE THE SYSTEM. IDENTIFICATION OF BRANCH CIRCUITS SHALL BE TYPEWRITTEN ON DIRECTORY CARDS FURNISHED WITH ALL PANELS AND PLACED IN THE CARD HOLDER ON THE DOOR. PROVIDE NEW TYPEWRITTEN DIRECTORY CARDS WITH UPDATED SCHEDULES FOR ALL EXISTING PANELS WITH NEW OR MODIFIED CIRCUITS. 17. AFTER INSTALLATION, TEST FOR GROUNDS, SHORT CIRCUITS AND PROPER FUNCTION OF EACH SYSTEM AND RELATED WIRING. FAULTS IN THE INSTALLATION SHALL BE CORRECTED. 18. INSULATION RESISTANCE TESTS SHALL BE MADE ON THE ELECTRICAL SYSTEM WITH AN APPROVED MEGOHMMETER. 19. A GROUND CONTINUITY TEST SHALL BE MADE ON THE ENTIRE GROUNDING SYSTEM FROM THE SERVICE TO EVERY OUTLET. 20. AFTER ALL TESTS AND ADJUSTMENTS HAVE BEEN COMPLETED, CLEAN ALL EQUIPMENT LEAVING EVERYTHING IN WORKING ORDER AT THE COMPLETION OF THIS WORK. CLEAN UGHTING FIXTURES, OUTLET BOX PLATES, PANEL AND CABINET INTERIORS AND EXTERIORS, ETC., OF DIRT, DUST , DEBRIS AND PAINT, AFTER ALL OTHER TRADES HAVE COMPLETED THEIR WORK. 21. PROVIDE A TEMPORARY ELECTRICAL SERVICE ADEQUATE IN SIZE FOR HEATING, FOR THE USE OF ALL TRADES AND FOR THE LIGHTING OF EACH ROOM DURING CONSTRUCTION. TEMPORARY WIRING SHALL BE TO OSHA REQUIREMENTS. TEMPORARY SERVICE CAN BE EXTENDED FROM THE OWNER'S EXISTING POWER DISTRIBUTION SYSTEM. THE OWNER MUST APPROVE OF THE POINT OF SUPPLY, THE METHOD OF EXTENSION AND THE ROUTING OF NECESSARY TEMPORARY FEEDERS. PROVIDE A TEMPORARY TELEPHONE SERVICE FOR THE USE OF ALL TRADES DURING CONSTRUCTION. 22. DO ALL CUTTING AND PATCHING IN EXISTING CONSTRUCTION AS NECESSARY FOR INSTALLATION OF THIS WORK. HAVE CUTTING DONE BY SKILLED MECHANICS AS CAREFULLY AS POSSIBLE AND WITH AS LITTLE DAMAGE AS POSSIBLE. 23. DEMOUTION OF EXISTING ELECTRICAL EQUIPMENT MAY BE A PART OF THE ELECTRICAL WORK. REFER TO THE DRAWINGS FOR EXACT REQUIREMENTS. ELECTRICAL SPECIFICATIONS SECTION 16050 - BASIC MATERIALS AND METHODS 1. ALL BOXES SHALL BE RIGIDLY SUPPORTED FROM THE BUILDING STRUCTURE INDEPENDENT OF THE CONDUIT SYSTEM. ALL BOXES SHALL BE 4" SQUARE BOXES MINIMUM WITH RAISED COVERS SUITABLE FOR THE WALL MATERIAL. 2. RACEWAYS: A. CONDUIT SHALL BE HEAVY WALL GALVANIZED STEEL OR INTERMEDIATE GRADE STEEL IN EXTERIOR MASONRY WALLS; IN MASONRY WALLS BELOW GRADE; IN CRAWL SPACES; IN THE GROUND; IN CONCRETE FLOORS, WALLS OR SLABS; AND IN DAMP OR WET LOCATIONS. EXPOSED CONDUITS IN HIGH TRAFFIC AREAS WHERE CONDUITS ARE SUBJECT TO PHYSICAL ABUSE SHALL BE HEAVY WALL RIGID GALVANIZED STEEL TO A LEVEL OF 8 FEET ABOVE THE FINISHED FLOOR. ALL OTHER INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT), UNLESS OTHERWISE NOTED ON THE DRAWINGS OR WITHIN THESE SPECIFICATIONS. CONDUITS SHALL BE 3/4" TRADE SIZE, MINIMUM, UNLESS OTHERWISE NOTED ON THE DRAWINGS OR WITHIN THESE SPECIFICATIONS. B. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOXES TO RECESSED UGHTING FIXTURES, 6 FT. IN LENGTH. INSTALLATION OF MANUFACTURED WIRING SYSTEMS SHALL COMPLY WITH ARTICLE 604 OF THE NATIONAL ELECTRICAL CODE. ALL BRANCH CIRCUIT HOMERUN CONDUITS WITHIN THE CEILING SPACE COMPLETE TO THE PANELBOARDS SHALL BE EMT CONDUIT. FLEXIBLE CONDUIT MAY NOT BE UTILIZED TO WIRE FIXTURES, OUTLETS, ETC IN A DAZY CHAIN FASHION. C. CONDUIT CONNECTIONS TO MOTORS SHALL BE FLEXIBLE METAL CONDUIT "SEAL -TITE" TYPE "UA" AS MANUFACTURED BY THE AMERICAN BRASS COMPANY OR EQUIVALENT AND SHALL BE OF THE SAME SIZE AS THE FEEDER CONDUIT. D. CONDUIT CONNECTIONS TO UNDERCABINET TYPE LIGHTING FIXTURES SHALL BE 3/8" FLEXIBLE METAL CONDUIT OR MC TYPE CABLE FROM THE WALL OUTLET BOX TO THE FIXTURE HOUSING. 3. WIRING DEVICES: A. LOCAL LIGHT SWITCHES SHALL BE 20 AMPERE, 120/277 VOLTS, AC SPECIFICATION GRADE, WITH GROUNDING TERMINAL, AS MANUFACTURED BY HUBBELL, OR EQUIVALENT, #CS -122 SERIES. B. FLUORESCENT DIMMERS SHALL BE LUTRON "NOVA T -STAR" SERIES, #NTF -10 FOR 120 VOLT, #NTF -40 -277 FOR 277 VOLT. 3 -WAY, 2 LOCATION FLUORESCENT DIMMERS SHALL BE LUTRON °NOVA T -STAR" SERIES, #NTF -103P FOR 120 VOLT, #NTF -103P -277 FOR 277 VOLT. C. INCANDESCENT DIMMERS SHALL BE LUTRON "NOVA T- -STAR" UNEAR SLIDE SERIES - FOR UP TO 1500 WATT DIMMERS AND LUTRON "NOVA" LINEAR SLIDE SERIES FOR 2000 WAIT DIMMERS. D. DUPLEX RECEPTACLES SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING. GENERAL PURPOSE "SPECIFICATION GRADE" DUPLEX RECEPTACLES: HUBBELL #CR5352. ISOLATED GROUND DUPLEX RECEPTACLES: HUBBELL #CR5352 IG - ORANGE. HOSPITAL GRADE DUPLEX RECEPTACLES: HUBBELL #8300H. TAMPER RESISTANT "SAFETY TYPE" DUPLEX RECEPTACLES: HUBBELL #HBL8300SG. E. DUPLEX RECEPTACLES WHERE INDICATED ON THE DRAWINGS OR WHERE REQUIRED BY CODE, SHALL HAVE AN INTEGRAL GROUND FAULT PROTECTOR AND SHALL BE 20A, 125V, 2 POLE, 3 WIRE GROUNDING: HUBBELL #GFR5352. GROUND FAULT RECEPTACLES SHALL NOT BE THRU - WIRED. PROVIDE INDIVIDUAL DUPLEX RECEPTACLES AS SHOWN ON THE DRAWINGS. HOSPITAL GRADE GROUND FAULT DUPLEX RECEPTACLES: HUBBELL #HGF8300. F. ALL SWITCHES, DIMMERS, AND RECEPTACLES SHALL BE IVORY UNLESS OTHERWISE INDICATED WITHIN THESE SPECIFICATIONS. VERIFY COLOR WITH THE ARCHITECT PRIOR TO PROCUREMENT OF THE DEVICES. ALL COVERPLATES SHALL BE SMOOTH HIGH IMPACT THERMOPLASTIC FINISH WITH COLOR TO MATCH THE DEVICES. EMERGENCY RECEPTACLES AND SWITCHES SHALL BE RED, WITH COVERPLATES TO MATCH THE FINISH OF THE OTHER COVERPLATES PROVIDED IN THE AREA. IN UNFINISHED AREAS, USE CADMIUM PLATED, ROUND CORNER, STEEL COVERPLATES FOR SURFACE MOUNTED OUTLET BOXES. BOTH THE WIRING DEVICES AND THE COVERPLATES SHALL BE BY THE SAME MANUFACTURER. G. MANUAL MOTOR STARTERS SHALL BE WESTINGHOUSE TYPE "MS" SERIES OR EQUIVALENT, WITH PILOT LIGHT, OVERLOADS AND ON /OFF SWITCH; FLUSH MOUNTED IN FINISHED AREAS. MANUAL MOTOR STARTERS SHALL BE MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, ITE OR ALLEN BRADLEY. H. THE FOLLOWING ARE EQUIVALENT WIRING DEVICES: 1. RECEPTACLES: #5362 SERIES MANUFACTURED BY PASS AND SEYMOUR OR LEVITON. 2. LIGHT SWITCHES: PASS AND SEYMOUR #20AC1 SERIES OR LEVITON #1221 SERIES. 3. DIMMERS: NO OTHER MANUFACTURERS ARE ACCEPTABLE. 4. WIRE AND CABLE FOR BRANCH CIRCUITS AND FOR FEEDERS SHALL BE 600 VOLT, TYPE THHN/THWN COPPER ONLY, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. MINIMU FOR POWER AND LIGHTING BRANCH CIRCUITS SHALL BE #12. 5. SAFETY SWITCHES SHALL BE HEAVY DUTY FUSIBLE OR NONFUSIBLE TYPE AS INDICATED ON THE DRAWINGS, AND SHALL BE SUITABLE FOR THE VOLTAGE AND CURRENT RATINGS AS SHOWN ON THE DRAWINGS. 6. FUSES RATED 600 AMPERES OR LESS, 600 VOLTS OR LESS, SERVING ALL LOADS SHALL BE U.L CLASS RK1, DUAL ELEMENT, TIME DELAY AS MANUFACTURED BY BUSSMANN, OR APPROVED EQUIVALENT AS MANUFACTURED BY RELIANCE FUSE, GOULD SHAWMUT OR UTTELFUSE , GENERAL ELECTRIC OR S & C. 7. FUSES RATED 600 AMPERES OR MORE, 600 VOLTS OR LESS, SERVING ALL LOADS SHALL BE U.L. CLASS L, BUSSMANN, TIME DELAY TYPE KRP -C_SP, OR APPROVED EQUIVALENT AS MANUFACTURED BY RELIANCE FUSE, GOULD SHAWMUT OR LITTELFUSE , GENERAL ELECTRIC OR S & C ARE APPROVED. 8. ALL MOTOR STARTERS SHALL BE COMBINATION TYPE. STARTERS SHALL INCLUDE A FUSIBLE SAFETY SWITCH, A STARTER WITH THREE OVERLOAD DEVICES, AND A CONTROL CIRCUIT TRANSFORMER. THE ENCLOSURE SHALL BE NEMA TYPE 1, UNLESS OTHERWISE INDICATED ON THE DRAWINGS. EACH COMBINATION STARTER SHALL INCLUDE A CONTROL CIRCUIT TRANSFORMER WITH A 120 VOLT SECONDARY CONNECTION UNLESS OTHERWISE INDICATED ON THE DRAWINGS. ONE SIDE OF THE SECONDARY WINDING SHALL BE FUSED AND THE OTHER SIDE GROUNDED. STARTERS SHALL HAVE A GREEN RUNNING PILOT LIGHT, A HAND -OFF- AUTOMATIC SELECTOR SWITCH AND A MINIMUM OF TWO NORMALLY OPEN AND TWO NORMALLY CLOSED AUXILIARY CONTACTS, READY FOR CONTROL WIRING CONNECTIONS. 9. DISCONNECT SWITCHES AND MOTOR STARTERS SHALL BE MANUFACTURED BY SQUARE D', GENERAL ELECTRIC, SIEMENS /ITE, CUTLER HAMMER /WESTINGHOUSE, OR ALLEN BRADLEY. 10. ANY CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS AND WALLS SHALL BE FIRE STOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE SEALED IN ACCORDANCE WITH UL FIRE RESISTANCE HANDBOOK, VOLUME II AND SHALL BE RATED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS OR WALLS PENETRATED. 11. RACEWAY INSTALLATION: A. CONDUITS SHALL BE CONTINUOUS AND SECURED TO ALL BOXES IN SUCH A MANNER THAT EACH CONDUIT SYSTEM SHALL BE ELECTRICALLY CONTINUOUS FROM THE POINT OF SERVICE TO ALL OUTLET BOXES. RUN CONDUITS CONCEALED UNLESS OTHERWISE INDICATED. B. IN REMODELED AREAS WHERE IT IS NOT POSSIBLE TO INSTALL CONCEALED CONDUIT, PERMISSION MUST BE OBTAINED FROM THE ARCHITECT TO RUN SURFACE WIREMOLD OR CONDUIT. THE ROUTING AND ELEVATION OF SUCH SURFACE MOUNTED RACEWAYS MUST BE COORDINATED WITH THE ARCHITECT BEFORE INSTALLATION. EXPOSED RACEWAYS SHALL BE PAINTED TO MATCH ADJACENT FINISHES. C. INDIVIDUAL BRANCH CIRCUITS ARE SHOWN ON THE DRAWINGS FOR CLARITY. LIGHTING AND RECEPTACLE CIRCUITS MAY BE GROUPED FOR HOMERUNS, WITH A MAXIMUM OF (2) OR (3) CIRCUITS PER HOMERUN, DEPENDING ON THE SYSTEM. NEUTRAL CONDUCTORS IN RECEPTACLE CIRCUITS SERVING DATA EQUIPMENT LOADS SHALL NOT BE SHARED. D. WIRING FROM LEGALLY REQUIRED EMERGENCY AND STANDBY POWER GENERATION SOURCES SHALL BE KEPT INDEPENDENT OF EACH OTHER AND INDEPENDENT OF ALL OTHER BRANCH CIRCUIT WIRING, AND SHALL NOT ENTER THE SAME RACEWAY, CABLE, BOX, OR CABINET WITH OTHER WIRING, UNLESS SPECIFICALLY ALLOWED BY THE NATIONAL ELECTRICAL CODE. 11. WIRE AND CABLE INSTALLATION: A. PULL WIRE AND CABLES INTO CONDUIT USING IDEAL INDUSTRIES "YELLOW 190 ", OR EQUIVALENT. B. COLOR CODE WIRE AND CABLE FOR CIRCUITS AS CALLED FOR IN THE NATIONAL ELECTRICAL CODE. COLOR CODING OF FEEDERS SHALL BE BY MEANS OF COLORED TAPE AT TERMINALS. 12. WIRING DEVICE INSTALLATION: A. ADJACENT DEVICES SHALL BE MOUNTED IN GANGED BOXES WITH COMMON COVER PLATES. B. VERIFY MOUNTING HEIGHTS AND LOCATIONS WITH THE ARCHITECT BEFORE ROUGH -IN. REFER TO DETAILS AND INTERIOR WALL ELEVATIONS SHOWN ON THE ARCHITECTURAL DRAWINGS. C. OUTLETS SHALL NOT BE INSTALLED BACK TO BACK. D. ALL RECEPTACLES SHALL BE MOUNTED WITH THE GROUND OPENING ABOVE THE PHASE AND NEUTRAL OPENINGS. E. ALL DEVICES SHALL BE SECURED WITH MORE THAN A SINGLE SCREW. 13. ALL HARDWARE, SUPPORTS, HANGERS, BRACKETS, ANGLE IRON, CHANNELS, RODS AND CLAMPS NECESSARY TO INSTALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED TO SUIT THE FIELD CONDITIONS AND THE APPLICATIONS INTENDED AS SHOWN ON THE DRAWINGS. THE USE OF PERFORATED STRAPS IS NOT PERMITTED. NO 1. It CHMENTS AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. 14. ALL EQUIPMENT MOUNTED ON EQUIPMENT ROOM WALLS SHALL BE ATTACHED TO 3/4" PLYWOOD BOARDS, PAINTED WITH FIRE RESISTANT PAINT. 15. DISCONNECT SWITCHES MOUNTED ON OR ADJACENT TO MECHANICAL AND BUILDING EQUIPMENT SHALL BE LOCATED TO ALLOW THE PROPER WORKING CLEARANCE AS DEFINED IN ARTICLE 110 OF THE NATIONAL ELECTRICAL CODE. 16. ELECTRICAL INSTALLATIONS IN HOLLOW SPACES, VERTICAL SHAFTS, AND VENTILATION OR AIR- HANDLING DUCTS SHALL BE MADE SO THAT THE POSSIBLE SPREAD OF FIRE OR PRODUCTS OF COMBUSTION WILL NOT BE SUBSTANTIALLY INCREASED. OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH FIRE-RESISTANT-RATED WALLS, PARTITIONS, FLOORS, OR CEILINGS SHALL BE FIRESTOPPED USING APPROVED METHODS TO MAINTAIN THE FIRE RESISTANCE RATING. MAINTAIN A MINIMUM OF 24 -IN. HORIZONTAL SEPARATION BETWEEN BOXES INSTALLED ON OPPOSITE SIDES OF WALLS. SECTION 16400 - SERVICE AND DISTRIBUTION 1. GROUND ALL ELECTRICAL SYSTEM CONDUITS, MOTORS, PANELS AND OTHER EXPOSED NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ALL PROVISIONS OF THE NATIONAL ELECTRICAL CODE, STATE BUILDING CODE AND LOCAL OR REGIONAL CODES. 2. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH FEEDER AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS. GROUNDING CONDUCTORS SHALL BE SIZED IN ACCORDANCE WITH N.E.C. ARTICLE 250. 3. SYSTEM NEUTRAL CONDUCTORS SHALL BE GROUNDED AT THE SOURCE. NEUTRAL CONDUCTORS SHALL NOT BE USED FOR EQUIPMENT GROUNDING. 4. THE GROUNDING CONDUCTOR FOR BRANCH CIRCUITS FEEDING ISOLATED GROUND RECEPTACLES SHALL BE CONNECTED ONLY AT THE ISOLATED GROUND RECEPTACLE GROUND TERMINALS, AND AT THE GROUND BUS OF THE SERVING PANEL. 5. FURNISH AND INSTALL BRANCH CIRCUIT BREAKER PANELBOARDS EQUIPPED WITH CIRCUIT BREAKERS, WITH FRAME AND TRIP RATINGS LISTED ON THE DRAWINGS. CIRCUIT BREAKERS SHALL BE THERMAL- MAGNETIC, MOLDED CASE BOLT -ON TYPE. ALL CURRENT CARRYING PARTS OF THE BUS STRUCTURE SHALL BE TIN- PLATED ALUMINUM. EACH PANELBOARD SHALL CONTAIN A GROUNDING BUS. 6. EACH PANELBOARD SERVED DIRECTLY BY A TRANSFORMER SECONDARY SHALL HAVE A MAIN CIRCUIT BREAKER OR OTHER MAIN OVERCURRENT PROTECTION, SIZED IN ACCORDANCE WITH ARTICLE 240 OF THE NATIONAL ELECTRICAL CODE. 7. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, SIEMENS /ITE, GENERAL ELECTRIC OR CUTLER HAMMER /WESTINGHOUSE. 8. PANELS SHALL BE MOUNTED SO THAT TOP OF THE CABINET IS AT 6' -0" ABOVE FLOOR. A GLAZED DIRECTORY FRAME SHALL BE PROVIDED INSIDE EACH PANEL DOOR AND SHALL BE OF SUFFICIENT SIZE TO GIVE A COMPLETE DESCRIPTION OF EACH CIRCUIT. TYPED DIRECTORY CARDS SHALL BE PROVIDED LISTING EACH CIRCUIT SERVED. 9. THE BRANCH CIRCUIT NUMBERS USED ON THE DRAWINGS SHALL BE APPLIED FOR THE CONSTRUCTION. HOWEVER, AT THE COMPLETION OF THE WORK, CIRCUIT NUMBER ADJUSTMENTS SHALL BE MADE AS REQUIRED TO PROVIDE BALANCED PHASE LOADING ON EACH PANELBOARD. 10. FLUSH MOUNTED PANELBOARDS SHALL BE INSTALLED WITH A MINIMUM OF THREE EMPTY 3/4" CONDUITS STUBBED UP TO THE NEAREST ACCESSIBLE CEILING SPACE FOR CONVENIENT FUTURE EXPANSION. 11. TRANSFORMERS SHALL BE 115 DEGREES C. TEMPERATURE RISE ABOVE A 40 DEGREES C. AMBIENT. ALL INSULATING MATERIALS SHALL BE IN ACCORDANCE WITH NEMA ST20 STANDARD FOR A 185 DEGREES C. UL COMPONENT RECOGNIZED INSULATION SYSTEM. SOUND LEVELS SHALL NOT EXCEED NEMA STANDARDS. TRANSFORMER SHALL HAVE (4) 2 -1/2% FULL CAPACITY PRIMARY TAPS. 12. TRANSFORMERS SHALL. BE AS MANUFACTURED BY SQUARE D, SIEMENS /ITE, GENERAL ELECTRIC, OR CUTLER HAMMER /WESTINGHOUSE. 13. PROVIDE A 6" CONCRETE PAD FOR FLOOR MOUNTING OF EACH TRANSFORMER RATED 75 KVA AND ABOVE, AND FOR SMALLER TRANSFORMERS IF INDICATED ON THE DRAWINGS. SECTION 16500 - LIGHTING 1. RECESSED INCANDESCENT FIXTURES SHALL HAVE THERMAL CUTOUT PROTECTION PER MANUFACTURER'S SPECIFICATIONS. 2. RECESSED FIXTURES SHALL BE PROVIDED TO BE COMPATIBLE WITH THE CEILING TYPES INSTALLED. VERIFY ALL CEILING TYPES WITH THE DIVISION 1 CONTRACTOR, OR WITH THE ARCHITECT BEFORE PROCUREMENT OF FIXTURES. 3. FLUORESCENT ELECTRONIC BALLASTS SHALL BE ONE, TWO, THREE OR FOUR LAMP TYPE TO ACCOMMODATE THE FIXTURES AND SWITCHING SPECIFIED, AND SHALL BE U.L LISTED, CLASS "P ". FLUORESCENT ELECTRONIC BALLASTS SHALL BE ADVANCE "CENTIUM" INSTANT START SERIES FOR T8 LAMPS OR EQUAL BY VALMONT, MOTOROLA, OR MAGNETEK /TRIAD. BALLASTS SHALL HAVE A MINIMUM POWER FACTOR OF 90 %, A MINIMUM BALLAST FACTOR OF 85%, A MAXIMUM CREST FACTOR OF 1.7, AND A MAXIMUM TOTAL HARMONIC DISTORTION OF 10 %. 4. FLUORESCENT COMPACT FLUORESCENT LAMP BALLASTS SHALL BE ENCAPSULATED TYPE - HIGH POWER FACTOR AND POWER FACTOR CORRECTED OR ELECTRONIC AS DESCRIBED IN THE LIGHTING FIXTURE SCHEDULE ON THE DRAWINGS. BALLASTS SHALL BE PROVIDED AS RECOMMENDED BY THE FIXTURE MANUFACTURER. 5. HIGH INTENSITY DISCHARGE BALLASTS SHALL BE CONSTANT WATTAGE, HIGH POWER FACTOR TYPE, WITH LOW NOISE. 6. INCANDESCENT LAMPS SHALL BE 130 VOLT RATED. A -LAMPS SHALL BE FROSTED. PROVIDE INCANDESCENT LAMPS AS RECOMMENDED BY THE FIXTURE MANUFACTURER. 7. FLUORESCENT UNEAR AND U -LAMPS SHALL BE T -8, 3500 DEG K. 8. COMPACT FLUORESCENT LAMPS SHALL BE 3500 DEG K. 9. HIGH PRESSURE SODIUM LAMPS SHALL BE CLEAR OR COATED AS RECOMMENDED BY THE FIXTURE MANUFACTURER. 10. METAL HAUDE LAMPS SHALL BE CLEAR OR COATED AS RECOMMENDED BY THE FIXTURE MANUFACTURER, AND SHALL BE 3700K UNLESS OTHERWISE SPECIFIED IN THE UGHTING FIXTURE SCHEDULE. A. FOR OPEN RELECTOR HIGH INTENSITY DISCHARGE FIXTURES, PROVIDE LAMPS LISTED FOR THE APPLICATION AS RECOMMENDED BY THE MANUFACTURER. 11. ALL LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, SYLVANIA, WESTINGHOUSE /PHILLIPS, OR VENTURE. PROVIDE CLEAR, LEXAN LAMP SLEEVES WITH END CAPS FOR EXPOSED FLUORESCENT LINEAR LAMPS. PROVIDE SPARE LAMPS AMOUNTING TO 10% (MINIMUM OF 3) OF EACH TYPE AND SIZE OF EACH LAMP USED ON THE PROJECT. 12. RECESSED AND SURFACE MOUNTED FIXTURES MOUNTED IN, OR ON CEILINGS OTHER THAN ACCESSIBLE LAY -IN CEILING SYSTEMS, SHALL BE SECURELY SUPPORTED IN A MANNER APPROVED BY THE ARCHITECT. MOUNTING SHALL ALSO BE IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE ARTICLE 410, AND AS RECOMMENDED BY THE FIXTURE MANUFACTURER. 13. RECESSED FIXTURES IN ACCESSIBLE LAY -IN CEILING SYSTEMS SHALL BE SUPPORTED AS FOLLOWS: A. THE GRID SYSTEM TEES SHALL BE SUPPORTED AT EACH CORNER OF EACH FIXTURE WITH A SUSPENDED CEILNG SUPPORT WIRE UP TO A BUILDING STRUCTURAL MEMBER, OR UP TO THE STRUCTURAL DECK. B. EACH FIXTURE SHALL ALSO BE SECURELY FASTENED TO THE GRID SYSTEM TEES BY MECHANICAL MEANS, SUCH AS BOLTS, SCREWS, RIVETS OR BY CLIPS IDENTIFIED FOR USE WITH THE TYPE CEILING FRAMING MEMBER INSTALLED. 14. ALL LIGHTING FIXTURES (INCLUDING "NORMALLY -OFF" EMERGENCY FIXTURES) THAT ARE CAPABLE OF BEING AIMED SHALL BE AIMED BY THE CONTRACTOR FOR THE OPTIMUM COVERAGE OF THEIR TASK, TO THE SATISFACTION OF, AND UNDER THE DIRECTION OF THE ARCHITECT. SECTION 16700 - COMMUNICATIONS 1. COMBINATION TELEPHONE /DATA OUTLET BOXES SHALL BE 4 INCHES SQUARE WITH SINGLE GANG PLASTER RINGS, UNLESS OTHERWISE NOTED. 2. TELEPHONE -ONLY, DATA -ONLY, FAX AND PAY TELEPHONE OUTLETS SHALL BE SIMILAR. 3. BLANK COVERPLATES SHALL BE PROVIDED FOR ALL UNUSED OUTLETS. 4. ALL CONDUITS REQUIRED FOR COMBINATION TELEPHONE /DATA OUTLETS AS SHOWN ON THE DRAWINGS SHALL BE INSTALLED COMPLETE WITH PULL WIRES. 5. PROVIDE CONDUIT FROM EACH OUTLET UP TO THE NEAREST ACCESSIBLE CORRIDOR CEILING SPACE AND PROVIDE A PLASTIC GROMMET AT EACH STUB. 6. 7. PROVIDE MISCELLANEOUS COMMUNICATION SYSTEM DEVICES AS SHOWN AND SPECIFIED ON THE DRAWINGS. INCLUDE SUFFICIENT WIRING, CONDUIT TERMINATIONS, ELECTRICAL BOXES, AND ALL OTHER NECESSARY MATERIAL AS RECOMMENDED BY THE SYSTEM SUPPLIERS. f ENERGY STAR ALL ELECTRICAL POWER DISTRIBUTION EQUIPMENT SHALL HAVE THE "ENERGY STAR" CERTIFICATION LABEL. REVIEWED FOR E. CODE. CE y �� �'� NEC NFPA A ,I ins City f'‘Y SI®N pr-r.) CFI'' FEB 19 2003 MN= & ASSOCIATES > Retail Design & Development 345 SPRINGSIDE DRIVE TEL 330 / 666 -6767 AKRON, OHIO 44333 -2434 FAX 330 / 666 -8334 STORE #753 WESTFIELD SOUTHCENTER SPACE #1010 466 SOUTHCENTER MALL TUKWILA, WA 98188 CONSULTANT: DRAWN BY: STADELMAN ISSUE / DATE: ISSUE 1 - CONSTRUCTION DOCUMENTS 01- 302008 REVISION : 02 -13 -08 -PER LANDLORD COMMENTS -AKS SHEET TITLE : ELECTRICAL SPECIFICATIONS SHEET NO. : E600