ELECTRICAL PERMIT
Parcel No.: 6364200010
Address: 1066 SOUTHCENTER MALL TUKW
Suite No:
Permit Number: EL08 -164
Issue Date: 05/12/2008
Permit Expires On: 11/08/2008
Tenant:
Name: GYMBOREE
Address: 1066 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: SARAH NIELSEN Phone: 800 541 -0821
Address: 1120 E 80 ST, STE 211 , BLOOMINGTON MN
Contractor:
Name: SIGN -TECH ELECTRIC LLC
Address: 5113 PACIFIC HWY E, SUITE 12 ,
Contractor License No: SIGNTEL988BG
Phone: 253 - 922 -2146
Expiration Date: 01/07/2010
DESCRIPTION OF WORK:
ELECTRICAL FOR TENANT IMPROVEMENT: NEW RECEPTACLES, SWITCHES, AND LIGHTING.
Value of Electrical: $22,000.00
Fees Collected:
$611.50
Type of Fire Protection: National Electrical Code Edition: 2005
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Date: (vI
I hereby certify that I have read and - ed this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the • e . • rmance of work. I am authorized to sign and obtain this electrical permit.
Signature:
Print Name s, -Z'!6- - /v rc- , .S/1-1
Date: Q1/
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -164 Printed: 05 -12 -2008
� •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 6364200010
Address: 1066 SOUTHCENTER MALL TUKW
Suite No:
Tenant: GYMBOREE
Permit Number: EL08 -164
Status: ISSUED
Applied Date: 02/19/2008
Issue Date: 05/12/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
T: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Print Name : /f / !d /7.Gf/`1
Date: /. —&
doc: Cond -Elec
EL08 -164 Printed: 05-12 -2008
CITY OF TUKWIliii
Community DevelopnWit Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Electrical Pe it No. OA
1(_/f
PoO
Project No.
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.: (6.,( -4420 - CYJ1
Site Address: lett, Scstker ce A-ex- t•-ItCa\
Tenant Name: 6a rripeyr2e.
Property Owners Name: NeStC■e 1c1 CCe DtT:x_ti 1 c- c. -
Mailing Address: i WA> 1 1 Los, e \eS r.p.A
City
Suite Number: 1Z 4c) Floor: 1
New Tenant: ❑ Yes (? No
State
Zip
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: Sn,et1r‘ k1t eA S PYN Day Telephone: bp'31 - O8 2i
Mailing Address: 1120 EaSIr •bw Sire - ti� 2 \ \, K \C>OCY4tr•cctCjf\l VI 1,..) S514-2c
City State Zip
Fax Number: S ISSa -1 • [
E -Mail Address: StcQh eACkex;o'nP corn
ELECTRICAL CONTRACTOR INFORMATION
Company Name: "T". f3 - l�
Mailing Address:
Zip
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Valuation of Project (contractor's bid price): $ 2,.. bhp
Scope of Work (please provide detailed information): r .1/41 64ES t Su ei eS, c r 9
Will service be altered? El Yes ?J No Adding more than 50 amps? ❑ Yes
Type of Use:
Type of work:
❑ New ❑ Addition ❑ Service Change ❑ Remodel le Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
Puget Sound Energy
El Seattle City Light
H:\Applications \Forms - Applications On Line'4 -2007 - Electrical Permit Application.doc
Page 1 of 2
r ..
RESIDENTIAS
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $140.00
(including an attachcd garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ca
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issucd within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
�-._. (�
Print Name: l C4' r lC
Mailing Address: l C �f/ $ Pr
Date:
Day Telephone: r got ref ( og2
City State Zip
Date Application Accepted:
Date Application Expires:
61)1 119t) 1 Staff Initials:/
H:\Applicationslrorms- Applications On Line•4 -2007 - Electrical Permit Applicatinn.doc
1
Page 2 of 2
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
RECEIPT NO: R08 -00471
Initials: JEM Payment Date: 02/19/2008
User ID: 1165
Payee: ELDER -JONES
Total Payment: 1,299.80
SET ID: S000000965 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08 -094 1,036.10
0.1 EL0,8 1Y64 110.70
M08 -047 124.00
PG08 -051 29.00
TOTAL: 1,299.80
TRANSACTION LIST:
Type Method Description Amount
Payment Check 50879 1,299.80
TOTAL: 1,299.80
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000.345.832.00.0 110.70
000/345.830 1,189.10
TOTAL: 1,299.80
8781 02/19 9 710 TOTAL 1299.80
INSPECTION RECORD
Retain a copy with permit
0'4 I (el
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION le
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: 61 1 6®_ ' /
/
Type of Inspection:
24 00
Address:
044 1141h
Date Called:
.I^
Special Instructions:
Date Wanted:
1O�
p.m.
Requester:
(((
Phone No:
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
01./ om-
Inspector:
Date: D 7 Jo ( )g
r7 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
fig- u�
PERMIT NO.
b
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: 6 141.16006
Type of Inspection:
2400
Address:
IOW tl
Date Called:
-oar
Special Instructions:
Date Wanted:
7 /07
a: m
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
— Ca i-GI RED..t 5 w (L ‘
-oar
M f!oP< p451461 ,per
`
nlEiir 4.5 IA/ P 4
- AJLhi geb.,
7
'Inspector:
$60.00 REINS'E TI N FEE REQUIRED. Prior to inspection, fee must be dOc
ri $ C 0 EE REQUI p ,
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: 01 07 aV
Receipt No.:
'Date:
...v_ . .._+.... -- - - - -- _ .,:ate �!e., .e.. «d,dmb A!
b
INSPECTION NO.
CITY OF TUK
6300 Southcenter BI ,
INSPECTION RECORD I,.�g« i��
Retain a copy with permit I[
PERMIT NO.
TUKWILA BUILDING DIVISION
Blvd., Tukwila, 98188 (206)431 -3 7
Project: (1g1115C0.
Type of Inspection: ,
Nfe-
Address: � ��
�
Date Called:
Special Instructions:
Date Wanted:
t ��
?( /
a
p.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
.5 ,P?o tr r3 )Z.Z
C.c,E ral
ef-ILIYJ
Inspector: jci
Date:
ova► QV
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
.10 • Aral. _w... - .1'._J..e L:.w- .�• - _ ' • _ •• W..s..... _r _h aural
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION it
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Pr ject:
Type of Inspection: f-0
ply', f At A/c V G / 6,17/T //t/6-
Ad rest. 6- G / 1
If LI,
Date Called:
W -(Pt1t)4'(/ /J/'IM .f/ld/7
gl)fidillikr -s1 49111/C 54WO/L T TV
Special Instructions:
Date Wanted:
. /
(�
l ,
b
[' a.m.
rrnu
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
ell ) NUA ,- '(( Mt r 6701 (a /cf
ply', f At A/c V G / 6,17/T //t/6-
9.- C YI? 1 COAA ffi'i4 17'07 11i4- .X
W -(Pt1t)4'(/ /J/'IM .f/ld/7
gl)fidillikr -s1 49111/C 54WO/L T TV
Si` /6-7 .MF f /iA c//4/., / /ii,t' 6 f/k7u/J
s/ /i'/4)GS i // X? 771 r" /a
.em
.5" COAO/' Cr i G-f /f -s /WZ.
//06e/401)7,-
rfl4AJ�G
4) sv/e /' e-04/46./ J,) / //t/
,%
of 14/1/1-! -- -(— 10,L.Y Ad fizz—PS-5' 04. Alto.) eakillI
Inspec r _ / a Date: /
l � /_ (,/ l tI/ // �JQ/ Lf /02 V/ �
In $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1---
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Ppe ti/�
I[[ ;;���++
Type of Inspectio
s4.��
A
Date Called:
pecial Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
oved per applicable codes. Corrections required prior to approval.
C • M M ENTS:
r04
Inspe
Date `Aj je
Li $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
1447- g,i-/
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
PERMIT NO.
(206)431 -3670
Project:
6)979e0/-'66,
Type of Inspection: 700
s/i f4cf oF MyA/AGL-
Address:
$ C ,z oie 6
i
Date Called:
01L -C, /G /A)6' -s /LfS //
Special Instructions:
5
Date Wanted:
5��'
a.m.
p.m.
Requester:
Phone No:
proved per applicable codes. Cdrrections required prior to approval.
COMMENTS: 706 v `
jys co,I/NNc r ivti.3s 7 /4
oa yre& - 577,1 i7; /1 6JA)
s/i f4cf oF MyA/AGL-
700
kfi ____
01L -C, /G /A)6' -s /LfS //
nspec /`'. f�Jlir �i1��D
Date: Air
$58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
3
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431 -3670
Project:
G Yt4 60/tE /.�
Type of Inspection:
Addr s•
Date Called:
penal Instructions:
'
Date Wanted:
Q
a.m.
p.m.
Requester:
Phone No:
roved per applicable codes. Corrections required prior to approval.
MMENTS: /00/9
(9/4 .crzff_ /km/7 5''of-/c/r
Date// f
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.: 1Date:
2
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
fu)S- !ley
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION It
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
�����
Type of Inspection: 7
i�0
Address:
Address:
4o�4 kiku
Date Called:
Special Instructions:
Date Wanted:
J / 3o
/
(112.....n. .
m.
Requester:
Phone No:
0 Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
PA-
O.K. — cog\ 1301-ex vAti,
r
Inspector:
L
Tn ildak,
Date:
05/3
/O
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
/
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION v
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
N(
Pr ect: f
Type of Inspection:
"
Address: ,�
4
Date Called:
-';
--)
Special Instructions:
Date Wanted:
�,
�^
a.m.
_ p.m.
'Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval. q
COMMENTS:
0,4/7
—. VN A ri I-- /-
-';
--)
/
Inspector.,
Date), 2
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
OIL
•
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
LTGINT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address GYMBOREE
Date 2/15/2008
1056 SOUTHCENTER MALL - SPACE 1240
For ul Ol�igtvp'a FOR
CODE COMPLIANCE
NFI f'°t 70 - NEC
MAR 1 1 2C08
TUKWILA, WA 98188
Applicant Name: GYMBOREE CORP.
Applicant Address: 500 HOWARD ST., SAN FRANCISCO, CA 94105
Applicant Phone: 415- 278 -7989
Project Description
I _1 New Building ,. , Addition U Alteration
Refer to WSEC Section 1513 for controls and commissioning
T1 ans Included
.
quirere , .Of Tukwila
Compliance Optlon
O Prescriptive (0) Lighting Power Allowance
(See Qualification Checklist (over). Indicate Prescriptive & LPA
�� st ��i
!III------Lan?.)DIV.
spaces clearly on
Alteration Exceptions
(check appropriate box - sec. 1132.3)
[ No changes are being made to the lighting
_ j Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2'"
Area in ft2
Allowed x Area
SALES
SALES FLOOR
1.50
2260.0
3390.0
SALES
MERCHANDISE DISPLAY EXEMPT. TBL 15 -1 FOOTNOTE 10
1.50
2260.0
3390.0
SALES
FIXTURE G2 - 2X2 FLUOR FIXTURE
22
62.0
1364.0
" From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
6780.0
Proposed Lighting Wattage
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
SALES
FIXTURE Al - RECESSED COMPACT FLUORESCENT
10
35.0
350.0
SALES
FIXTURE T3 - TRACKHEAD FIXTURE
52
45.0
2340.0
SALES
FIXTURE G2 - 2X2 FLUOR FIXTURE
22
62.0
1364.0
STOCK / SALES
4 FT STRIP FIXTURE
38
31.0
1178.0
TOILET
FIXTURE F - WALL MOUNT FIXTURE
1
32.0
32.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
5264. 0
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture. lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. RECEIVED
CITY OF TUKWILA
FEB 19 2008
PO-WIT CENTER
FILE C
Pv •[.(946_I(0.1
.r
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary (back)
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Prescriptive Spaces
Occupancy:
`) Warehouses, storage areas or aircraft storage hangers *Other
Qualification Checklist
Note. If occupancy type is "Other" and
fixture answer is checked, the number of
fixtures in the space is not limited by Code.
Clearly indicate these spaces on plans. If
not qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
1521)
r_j Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts
3. LED lights.
TABLE 15 -1 Unit Liahtina Power Allowance (LPA
Use'
LPAZ (W /sf)
Use'
LPA` (W /sf)
Automotive facility
0.9
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools, hospitals, institutions, museums, banks,
churches)
1.0
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations$
1.0
Cafeterias, fast food establishments',
restaurants /bars5
1.3
Post office
1.1
Dormitory
1.0
Retail10, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only), school
classrooms, day care centers
1.2
Gymnasia9, assembly spaces9
1.0
Theater. motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group 1 -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses11, storage areas
0.5
Hotel banquet/conference /exhibition hall'°
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
"laboratory" shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Libraries'
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies3 (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
Footnotes for Table 15 -1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Reserved.
7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft2 may be used.
8) Reserved.
9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W /ftZ.
10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following.
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points
of track attachment).
c) fitted with LED, tungsten halogen. fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted. the square footage for a warehouse may be defined. for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting,
2006 Washington State
Motor, and Transformer Permit Plans Checklist
LTG -CHK
Ravised July 2007
Nonresidential Energy Code Compliance Forms
Project Address GYMBOREE
Date 2/15/2008
The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements
in the 2006 Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
yes
1513.2
Area controls
Maximum limit per switch
n.a.
1513.3
Daylight zone control
Schedule with type and features, indicate locations
vertical glazing
Indicate vertical glazing on plans
overhead glazing
Indicate overhead glazing on plans
n.a.
1513.4
Display /exhib /special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features, indicate location
n.a.
(a) timer w /backup
Indicate location
n . a .
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
n.a.
1513.6.1
(a) occup. sensors
Schedule with type and locations
n.a .
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability):
Indicate size of zone on plans
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
EXIT SIGNS (Section 1514)
yes I
1514 IMax.
watts 'Indicate
watts for each exit sign
1
LIGHTING POWER ALLOWANCE (Section 1530 -1532)
yes
1531
Interior Lighting
Summary Form
Completed and attached. Schedule with fixture types.
lamps, ballasts, watts per fixture
n.a.
1532
Exterior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
MOTORS (Section 1511)
n.a. I
1511 IElec
motor efficiency IMECH
-MOT or Equipment Schedule with hp, rpm, efficiency 1
I
TRANSFORMERS (Section 1540)
yes I
1540 (Transformers
'Indicate
size and efficiency
1
If "no" is circled for any question, provide explanation:
2006 Washington State Nonresidential Ener. Code Compliance Form
Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK
2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007
Lighting - General Requirements
1513 Lighting Controls: Lighting, including exempt lighting
in Section 1512, shall comply with this section. Where
occupancy sensors are cited, they shall have the features
listed in Section 1513.6.1. Where automatic time switches
are cited, they shall have the features listed in Section
1513.6.2.
1513.1 Local Control and Accessibility: Each space,
enclosed by walls or ceiling- height partitions, shall be
provided with lighting controls located within that space. The
lighting controls, whether one or more, shall be capable of
turning off all lights within the space. The controls shall be
readily accessible, at the point of entry/exit, to personnel
occupying or using the space.
EXCEPTIONS: The following lighting controls may be
centralized in remote locations'
1. Lighting controls for spaces which must be used as
a whole.
2. Automatic controls.
3. Controls requiring trained operators.
4. Controls for safety hazards and security.
1513.2 Area Controls: The maximum lighting power that
may be controlled from a single switch or automatic control
shall not exceed that which is provided by a 20 ampere circuit
loaded to not more than 80 %. A master control may be
installed provided the individual switches retain their capability
to function independently. Circuit breakers may not be used
as the sole means of switching.
EXCEPTIONS: 1. Industrial or manufacturing process
areas, as may be required for production.
2. Areas less than 5% of the building footprint for
footprints over 100,000 ft2.
1513.3 Daylight Zone Control: All daylighted zones, as
defined in Chapter 2, both under overhead glazing and
adjacent to vertical glazing, shall be provided with individual
controls, or daylight- or occupant- sensing automatic controls,
which control the lights independent of general area lighting.
Contiguous daylight zones adjacent to vertical glazing are
allowed to be controlled by a single controlling device
provided that they do not include zones facing more than two
adjacent cardinal orientations (i.e. north, east, south, west).
Daylight zones under overhead glazing more than 15 feet
from the perimeter shall be controlled separately from daylight
zones adjacent to vertical glazing.
EXCEPTION: Daylight spaces enclosed by walls or
ceiling height partitions and containing 2 or fewer light
fixtures are not required to have a separate switch for
general area lighting.
1513.4 Display, Exhibition and Specialty Lighting
Controls: All display, exhibition or specialty lighting shall be
controlled independently of general area lighting.
1513.5 Automatic Shut -off Controls, Exterior: Lighting for
all exterior applications shall have automatic controls capable
of turning off exterior lighting when sufficient daylight is
available or when the lighting is not required during nighttime
hours. Lighting not designated for dusk -to -dawn operation
shall be controlled by either:
a. A combination of a photosensor and a time switch;
or
b. An astronomical time switch.
Lighting designated for dusk -to -dawn operation shall be
controlled by an astronomical time switch or photosensor. All
time switches shall be capable of retaining programming and
the time setting during loss of power for a period of at least 10
hours.
EXCEPTION: Lighting for covered vehicle entrances
or exits from buildings or parking structures where
required for safety, security, or eye adaptation.
1513.6 Automatic Shut -Off Controls, Interior: Buildings
greater than 5,000 ft2 and all school classrooms shall be
equipped with separate automatic controls to shut off the
lighting during unoccupied hours. Within these buildings, all
office areas less than 300 ft2 enclosed by walls or ceiling -
height partitions, and all meeting and conference rooms, and
all school classrooms, shall be equipped with occupancy
sensors that comply with Section 1513.6.1. For other spaces,
automatic controls may be an occupancy sensor, time switch
or other device capable of automatically shutting off lighting.
EXCEPTIONS: 1. Areas that must be continuously
illuminated (e.g., 24 -hour convenience stores), or
illuminated in a manner requiring manual operation of
the lighting.
2. Emergency lighting systems.
3. Switching for industrial or manufacturing process
facilities as may be required for production.
4. Hospitals and laboratory spaces.
5- Areas in which medical or dental tasks are
performed are exempt from the occupancy sensor
requirement.
1513.6.1 Occupancy Sensors: Occupancy sensors shall
be capable of automatically turning off all the lights in an
area, no more than 30 minutes after the area has been
vacated.
Light fixtures controlled by occupancy sensors shall have a
wall- mounted, manual switch capable of turning off lights
when the space is occupied.
EXCEPTION: Occupancy sensors in stairwells are
allowed to have two step lighting (high -light and low -
light) provided the control fails in the high -light position.
1513.6.2 Automatic Time Switches: Automatic time
switches shall have a minimum 7 day clock and be capable
of being set for 7 different day types per week and
incorporate an automatic holiday "shut -off' feature, which
turns off all loads for at least 24 hours and then resumes
normally scheduled operations. Automatic time switches
shall also have program back -up capabilities, which prevent
the loss of program and time settings for at least 10 hours, if
power is interrupted.
Automatic time switches shall incorporate an over -ride
switching device which:
a. is readily accessible;
b. is located so that a person using the device can see the
lights or the areas controlled by the switch, or so that the
area being illuminated is annunciated;
c. is manually operated;
d. allows the lighting to remain on for no more than 2 hours
when an over -ride is initiated; and
e. controls an area not exceeding 5,000 ft2 or 5% of the
building footprint for footprints over 100,000 ft2, whichever is
greater.
1513.7 Commissioning Requirements: For lighting
controls which include daylight or occupant sensing
automatic controls, automatic shut -off controls, occupancy
sensors, or automatic time switches, the lighting controls
shall be tested to ensure that control devices, components,
equipment and systems are calibrated, adjusted and operate
in accordance with approved plans and specifications.
Sequences of operation shall be functionally tested to
ensure they operate in accordance with approved plans and
specifications. A complete report of test procedures and
results shall be prepared and filed with the owner. Drawing
notes shall require commissioning in accordance with this
paragraph.
1514 Exit Signs: Exit signs shall have an input power
demand of 5 Watts or less per sign.
Motors - General Requirements
1511 Electric Motors: All permanently wired polyphase
motors of 1 hp or more, which are not part of an HVAC
system, shall comply with Section 1437.
EXCEPTIONS: 1. Motors that are an integral part of
specialized process equipment.
2. Where the motor is integral to a listed piece of
equipment for which no complying motor has been
approved.
Transformers - General Requirements
SECTION 1540 — TRANSFORMERS
The minimum efficiency of a low voltage dry-type
distribution transformer shall be the Class 1 Efficiency Levels
for distribution transformers specified in Table 4 -2 of the
"Guide for Determining Energy Efficiency for Distribution
Transformers" published by the National Electrical
Manufacturers Association (NEMA TP- 1- 2002).
2004 Washington State Nonresidential Energy Code Compliance Form
Mechanical
Summary
MECH -;SUM
2004 Washington State Nonresidential Energy Code Compliance Forms
Revised May 2005
Project Info
Project Address
GYMBOREE
Model No.'
,Aar 7 Zoo:
Total CFM
SOUTHCENTER MALL
‘7'. -
1 I e t,l$ .'
LA)
70
vtpR 1 1 ni3B
m.. _ - . ----t
Location
SEATTLE, WASHINGTON
GODE
Applicant Name:
55080
NI-13A
Applicant Address:
N/A
N/A
Applicant Phone:
, 1
Project Description
Briefly describe mechanical
system type and features,
-1 Includes Plans
VAV BOX WITH ELECTRIC HEAT
B
City
of iuk '4ila
i I4G DN .10
Include documentation requiring compliance with commissioning requirements, Section 1416.
Compliance Option
Simple System 0 Complex System 0 Systems Analysis
(See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.)
Equipment Schedules
The following information is required to be incorporated with the mechanical equipment schedules on the
plans. For projects without plans, fill in the required information below.
Cooling Equipment Schedule
Equip.
ID
Brand Name'
Model No.'
Capacity2
Btu /h
Total CFM
OSA CFM
or Econo?
SEER
or EER
IPLV3
Location
VAV -1
TITUS
ATQS -7
55080
2550
590
N/A
N/A
IN SPACE
RECEIVED
CITY OF TUKWILA
2008
ao..... iv.
FED 19
PERMIT CENTER
Heating Equipment Schedule
Equip.
ID
Brand Name'
Model No.'
Capacity2
Btu /h
Total CFM
OSA cfm
or Econo?
Input Btuh
Output Btuh
Efficiency"
N/A
VAV -1
TITUS
ATQS -7
17070
2550
590
IN VAV
9 KW
RECEIVED
CITY OF TUKWILA
2008
ao..... iv.
FED 19
PERMIT CENTER
Fan Equipment Schedule
Equip.
ID
Brand Name'
Model No.'
CFM
sp1
HP /BHP
Flow Controls
Location of Service
VAV-1
TITUS
DTQS -7
2550
0.50
1 HP
VAV
IN VAV
ao..... iv.
11f available. 2 As tested according to Table 14 -1A through 14 -1 G. If required. 4 COP, HSPF Combustion r • cy AF
applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 1
Pa e
2004 Washington State Nonresidential Energy Code Compliance Form
Mechanical Summary (back)
MECH -S
UM
System Description
See Section 1421 for full description
of Simple System qualifications.
If Heating /Cooling
or Cooling Only:
C Constant vol? E Air cooled? nl Packaged sys? I —J <20,000 Btuh?
IA Split system? [I Economizer included?
If Heating Only:
� < 5000 cfm?
� <70% outside air?
Decision Flowchart
Use this flowchart to determine if project qualifies for Simple System Option. If not, either the
Complex System or Systems Analysis Options must be used
C START
Heating Only
Heating /Cooling
or Cooling Only
Reference
Section 1420
Yes —
Yes*
Yes
Yes
Reference
\Section 1423
Simple System
Allowed
(section 1420)
otal Ca .
wo economize
<240,000 Btuh
or 10 %?
Yes
Yes—
Ye <54,000 No - --
Btuh?
No
Use Complex
Systems
(section 1430)
Complex Systems
Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which
Complex Systems requirements are applicable to this project.
2004 Washin ton State Nonresidential Ener• Code Com•liance Form
Electric Motors MECH -MOT
2004 Washington State Nonresidential Energy Code Compliance Forms
Revised May 2005
Project Address
GYMBOREE
Date
2/15/2008
Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired
polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm
(unless one of the exceptions below applies).
For Building Department Use
Motor
No. or
Location
HP
Type
(open /closed
Description of Application or Use
Synch.
Speed
Min.Nom.
Full load
Efficiency
VAV
1
open
POWERED VAV
1200
85.0%
Minimum Nominal Full-Load Efficienc
Synchronous
Speed (RPM)
HP
1.0
1.5
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
125
150
200
Open Motors
Closed Motors
3,600
1,800
1,200
3,600
1,800
1,200
Efficiency (%)
Efficiency (%)
-
82.5
80.0
75.5
82.5
80.0
82.5
84.0
84.0
82.5
84.0
85.5
84.0
84.0
85.5
84.0
84.0
86.5
84.0
86.5
86.5
85.5
87.5
87.5
85.5
87.5
87.5
87.5
87.5
87.5
87.5
88.5
88.5
88.5
89.5
89.5
88.5
89.5
90.2
89.5
89.5
89.5
89.5
91.0
90.2
90.2
91.0
90.2
90.2
91.0
91.0
90.2
91.0
90.2
91.0
91.7
91.7
91.0
92.4
91.7
91.0
92.4
92.4
91.0
92.4
91.7
91.7
93.0
93.0
91.7
93.0
93.0
92.4
93.0
93.0
92.4
93.0
93.0
93.0
93.6
93.6
93.0
93.6
93.6
93.0
94.1
93.6
93.0
94.1
93.6
93.0
94.1
94.1
93.6
94.5
94.1
93.6
94.5
94.1
94.5
94.5
94.1
93.6
95.0
94.5
94.5
95.0
95.0
94.5
95.0
94.5
95.0
95.0
95.0
Exceptions:
1. Motors in systems designed to use more
than one speed of a multi -speed motor.
2. Motors already included in the efficiency
requirements for HVAC equipment (Tables 14 -1
or
14 -2).
3. Motors that are an integral part (i.e. not
easily removed and replaced of specialized
process equipment (i.e. equipment which
requires a special motor, such as an explosion -
proof motor).
4. Motors integral to a listed piece of
equipment for which no qualifying motor has
been approved (i.e. if the only U.L. listing for the
equipment is with a Tess- efficient motor and
there is no energy - efficient motor option).
For motors claiming an exception, list motor
and note which exception applies.
2004 Washington State Nonresidential Energy Code Compliance Form
Mechanical Permit Plans Checklist MECH -CHK
2004 Washington State Nonresidential Energy Code Compliance Forms Revised May 2005
Project Address GTMBOEEE
'Date 2/15/2008
The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the
Washington State Nonresidential Energy Code.
Applicability
(yes, no, n.a.)
I Code
Section Component
Information Required
Location
on Plans
Building Department
I Notes
HVAC REQUIREMENTS (Sections 1401 -1424)
1411
Equipment performance
n.a.
1411.4
Pkg. elec. htg.& clg.
List heat pumps on schedule
n.a.
1411.1
Minimum efficiency
Equipment schedule with type, capacity, efficiency
n.a.
1411.1
Combustion htg.
Indicate intermittent ignition, flue /draft damper & jacket loss
1412
HVAC controls
yes
1412.1
Temperature zones
Indicate locations on plans
M1.0
n.a.
1412.2
Deadband control
Indicate 5 degree deadband minimum
n.a.
1412.3
Humidity control
Indicate humidistat
n.a .
1412.4
Automatic setback
Indicate thermostat with night setback and 7 diff. day types
yes
1412.4.1
Dampers
Indicate damper location and auto. controls & max. leakage
M3.0
n. a.
1412.4.2
Optimum Start
Indicate optimum start controls
n . a .
1412.5
Heat pump control
Indicate microprocessor on thermostat schedule
n. a.
1412.6
Combustion htg.
Indicate modulating or staged control
yes
1412.7
Balancing
Indicate balancing features on plans
M1.0
n. a.
1422
Thermostat interlock
Indicate thermostat interlock on plans
n.a.
1423
Economizers
Equipment schedule
1413
Air economizers
n.a.
1413.1
Air Econo Operation
Indicate 100% capability on schedule
n.a.
1413.1
Wtr Econo Operation
Indicate 100% capacity at 45 degF db & 40 deg F wb
n.a.
1413.2
Water Econo Doc
Indicate clg load & water econoe & clg tower performance
n.a.
1413.3
Integrated operation
Indicate capability for partial cooling
0. a.
1413.4
Humidification Indicate direct evap or fog atomization w/ air economizer
1414
Ducting systems
yes
1414.1
Duct sealing
Indicate sealing necessary
M3.0
yes
1414.2
Duct insulation
Indicate R -value of insulation on duct
M1.0
n.a.
1415.1
Piping insulation
Indicate R -value of insulation on piping
1416
Completion Requirements
yes
1416.1 &2
Drawings & Manuals
Indicate requirement for record drawings and operation docs.
M1.0
yes
1416.3.2
Air Balancing
Indicate air system balance requirements
M1.0
n. a.
1416.3.3
Hydronic Balancing
Indicate hydronic system balance requirements
yes
1416.4
Commissioning
Indicate requirements for commissioning and prelim. Report
M1.0
0. a.
1424
Separate air sys.
Indicate separate systems on plans
yes
Mechanical 1Completed and attached. Equipment schedule with types,
Summary Form input/output, efficiency, cfm, hp, economizer
SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454)
1440
Service water htg.
n.a.
1441
Elec water heater
Indicate R -10 insulation under tank
n.a.
1442
Shut -off controls
Indicate automatic shut -off
0. a.
1443
Pipe Insulation
Indicate R -value of insulation on piping
n.a.
1452
Heat Pump COP
Indicate minimum COP of 4.0
n.a.
1452
Heater Efficiency
Indicate pool heater efficiency
n.a.
1453
Pool heater controls
Indicate switch and 65 degree control
n.a.
1454
Pool covers
Indicate vapor retardant cover
n.a.
1454
Pools 90+ degrees
Indicate R -12 pool cover
y question, provide explanation:
2004 Washington State Nonresidential Energy Code Compliance Form
Mechanical Permit Plans Checklist
2004 Washington State Nonresidential Energy Code Compliance Forms
MECH -CHK
Revised May 2005
Mechanical - General Requirements
1411.1 General: Equipment shall have a minimum performance at the
specified rating conditions not less than the values shown in Table 14 -1A
through 14.1G. If a nationally recognized certification program exists for a
product covered in Tables 14 -1A through 14 -1G, and it includes provisions
for verification and challenge of equipment efficiency ratings, then the
product shall be listed in the certification program
Gas•fired and oil -fired forced air furnaces with input ratings > 225,000
Btu /h (65 kW) shall also have an intermittent ignition or interrupted device
(I10). and have either mechanical draft (including power venting) or a flue
damper. A vent damper is an acceptable alternative to a flue damper for
furnaces where combustion air is drawn from the conditioned space. All
furnaces with input ratings > 225,000 Btu /h (65 kW), including electric
furnaces, that are not located within the conditioned space shall have
jacket losses not exceeding 0.75% of the input rating.
1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test
conditions and procedures when available. Where no applicable
procedures exist, data shall be furnished by the equipment manufacturer.
1411.3 Combination Space and Service Water Heating: For
combination space and service water heaters with a principal function of
providing space heat. the Combined Annual Efficiency (CAE) may be
calculated by using ASHRAE Standard 124 -1991. Storage water heaters
used in combination space heal and water heat applications shall have
either an Energy FActor (EF) or a CAE of not less than the fo lowing:
1411.4 Packaged Electric Heating and Cooling Equipment: Packaged
electric equipment providing both heating and cooling with a total cooling
capacity greater than 20,000 Btu /h shall be a heal pump.
Exception: Unstaffed equipment shaellers or cabinets used
solely for personal wireless service facilities.
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at
least one temperature control device. Each zone shall be controlled by
individual thermostatic controls responding to temperature within the zone
At a minimum, each floor of a building shall be considered as a separate
zone.
1412.2 Deadband Controls: When used to control both comfort heating
and cooling, zone thermostatic controls shall be capable of a deadband of
at least 5 degrees F within which the supply of heating and cooling energy
to the zone is shut off or reduced to a minimum.
Exceptions:
1. Special occupancy, special usage, or code requirements
where deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed
building energy analysis, heating and cooling thermostat
setpoints are set to the same temperature between 70
degrees F and 75 degrees F inclusive, and assumed to be
constant throughout the year.
3. Thermostats That require manual changeover between
heating and cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for
adding moisture. a humidistat shall be provided.
1412.4 Setback and Shut -Off: HVAC systems shall be equipped with
automatic controls capable of accomplishing a reduction of energy use
through control setback or equipment shutdown during periods of non -use
or alternate use of the spaces served by the system. The automatic
controls shall have a minimum seven -day clock and be capable of being
set for seven different day types per week.
Exceptions:
1. Systems serving areas which require continuous operation at
the same temperature setpoint
2. Equipment with full load demands of 2 kW (6,826 Btu /h) or
less may be controlled by readily accessible manual off -hour
controls.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets
serving conditioned spaces shall be equipped with dampers which close
automatically when the system is off or upon power failure.
Exceptions:
1. Systems serving areas which require continuous operation
2. Combustion air intakes.
3. Gravity (nonmotorized) dampers are acceptable in buildings
less than 3 stories in height
4. Gravity (nonmotorized) dampers are acceptable in exhaust
and relief outlets in the first story and levels below the first
story of buildings three or more stories in height.
1412.4.2 Optimum Start Controls: Heating and cooling systems with
design supply air capacities exceeding 10.000 cfm shall have optimum
start controls. Optimum start controls shall be designed to automatically
adjust the start time of an HVAC system each day to bring the space to
desired occupied temperature levels immediately before scheduled
occupancy. The control algorithm shall. as a minimum. be a function of the
difference between space temperature and occupied setpoint and the
amount of time prior to scheduled occupancy.
1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include
microprocessor controls that minimize supplemental heat usage during
start -up. set -up, and defrost conditions. These controls shall anticipate
need for heat and use compression heating as the first stage of heat.
Controls shall indicate when supplemental heating is being used through
visual means (e.g.. LED indicators).
1412.6 Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Blu /h shall have modulating or
staged combustion control.
Exceptions.
1. Boilers.
2. Radiant Heaters
1412.7 Balancing: Each air supply outlet or air or water terminal device
shall have a means for balancing, including but not limited to, dampers,
temperature and pressure test connections and balancing valves
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating
outside and return air dampers 10 provide 100 percent of the design supply
air as outside air to reduce or eliminate the need for mechanical cooling.
Water economizers shall be capable of providing the total concurrent
cooling load served by the conneted terminal equipment lacking airside
economizer, at outside air temperatures of 45 °F dry - bulb /40 °F wet -bulb
and below. For this calculation. all factors including solar and internal load
shall be the same as those used for peak load calculations, except for the
outside temperatures
Exception: Water economizers using air - cooled heat rejection
equipment may use a 35 °F dry -bulb outside air temperature for
this calculation. This exception is limited to a maximum of 20 tons
per building.
1413.2 Documentation: Water economizer plans submitted for approval
shall include the following information:
1. Maximum outside air conditions for which economizer is sized to
provide full cooling.
2. Design cooling load to be provided by economizer at this outside
air condition.
3. Heal rejection and terminal equipment performance data
including model number. flow rate. capacity. entering and leaving
temperature in full economizer cooling mode.
1413.3 Integrated Operation: Air economizers shall be capable of
providing partial cooling even when additional mechanical cooling is
required to meet the remainder of the cooling load
Exceptions:
1. Individual, direct expansion units that have a rated capacity
less than 65,000 Btu /h and use nonintegrated economizer
controls that preclude simultaneous operation of the
economizer and mechanical cooling.
2. Water - cooled water chillers with waterside economizer.
1413.4 Humidification: If an air economizer is required on a cooling
system for which humidification equipment is to be provided to maintain
minimum indoor humidity levels. then the humidifier shall be of the
adiabatic type (direct evaporative media or fog atomization type).
Exceptions:
1. Health care facilities where WAC 246 - 320 -525 allows only
steam injection humidifiers in ductwork downstream of final
filters. 1412.6 Combustion Heating Equipment Controls.
Combustion heating equipment with a capacity over 225,000
Btu /h shall have modulating or staged combustion control.
2. Systems with water economizer
3. 100% outside air systems with no provisions for air
recirculation to the central supply fan.
4 Nonadiabatic humidifiers cumulatively serving no more than
10% of a building's air economizer capacity as measured in
cfm. This refers to the system cfm serving rooms with stand
alone or duct mounted humidifiers.
1414 Ducting Systems
1414.1 Sealing: Duct work which is designed to operate at pressures
above 1/2 inch water column static pressure shall be sealed in accordance
with Standard RS -18. Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints_
2. Static pressure: 2 inches to 3 inches, seal all transverse joints
and longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints,
longitudinal seams and duct wall penetrations.
Duct tape and other pressure sensitive tape shall not be used as the
primary sealant where ducts are designed to operate at static pressures of
1 inch W.C. or greater
1414.2 Insulation: Ducts and plenums that are constructed and function
as part of the building envelope, by separating interior space from exterior
space. shall meet all applicable requirements of Chapter 13. These
requirements include insulation installation, moisture control, air leakage,
and building envelope insulation levels. Unheated equipment rooms with
combustion air louvers must be isolated from the conditioned space by
insulating interior surfaces to a minimum of R -11 and any exterior
envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2.800 cfm of total supply air capacity shall be
insulated to a minimum of R -7 and are not considered building envelope.
Other outside air duct runs are considered building envelope until they,
1. connect to the heating or cooling equipment, or
2 are isolated from the exterior with an automatic shut -off damper
complying with Section 1412.4.1.
Once outside air ducts meet the above listed requirements, any runs
within conditioned space shall comply with Table 14 -5 requirements.
Other ducts and plenums shall be thermally insulated per Table 14 -5
Exceptions:
1. Within the HVAC equipment.
2 Exhaust air ducts not subject to condensation
3. Exposed ductwork within a zone that serves that zone.
1415 Piping Systems
1415.1 insulation: Piping shall be thermally insulated in accordance with
Table 14 -6.
Exception: Piping installed within unitary HVAC equipment.
Water pipes outside the conditioned space shall be insulated in
accordance with Washington State Plumbing Code (WAC 51 -26)
1416 Completion Requirements (Refer to NREC Section 1416 and the
Building Commissioning Guidelines, published by the Building
Commissioning Association, for complete text and guidelines for building
completion and commissioning requirements )
EF
CAE
< 50 gal storage
0 58
0.71
50 to 70 gal storage
0.57
0.71
> 70 gal storage
0.55
0.70
1411.4 Packaged Electric Heating and Cooling Equipment: Packaged
electric equipment providing both heating and cooling with a total cooling
capacity greater than 20,000 Btu /h shall be a heal pump.
Exception: Unstaffed equipment shaellers or cabinets used
solely for personal wireless service facilities.
1412 Controls
1412.1 Temperature Controls: Each system shall be provided with at
least one temperature control device. Each zone shall be controlled by
individual thermostatic controls responding to temperature within the zone
At a minimum, each floor of a building shall be considered as a separate
zone.
1412.2 Deadband Controls: When used to control both comfort heating
and cooling, zone thermostatic controls shall be capable of a deadband of
at least 5 degrees F within which the supply of heating and cooling energy
to the zone is shut off or reduced to a minimum.
Exceptions:
1. Special occupancy, special usage, or code requirements
where deadband controls are not appropriate.
2. Buildings complying with Section 1141.4, if in the proposed
building energy analysis, heating and cooling thermostat
setpoints are set to the same temperature between 70
degrees F and 75 degrees F inclusive, and assumed to be
constant throughout the year.
3. Thermostats That require manual changeover between
heating and cooling modes.
1412.3 Humidity Controls: If a system is equipped with a means for
adding moisture. a humidistat shall be provided.
1412.4 Setback and Shut -Off: HVAC systems shall be equipped with
automatic controls capable of accomplishing a reduction of energy use
through control setback or equipment shutdown during periods of non -use
or alternate use of the spaces served by the system. The automatic
controls shall have a minimum seven -day clock and be capable of being
set for seven different day types per week.
Exceptions:
1. Systems serving areas which require continuous operation at
the same temperature setpoint
2. Equipment with full load demands of 2 kW (6,826 Btu /h) or
less may be controlled by readily accessible manual off -hour
controls.
1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets
serving conditioned spaces shall be equipped with dampers which close
automatically when the system is off or upon power failure.
Exceptions:
1. Systems serving areas which require continuous operation
2. Combustion air intakes.
3. Gravity (nonmotorized) dampers are acceptable in buildings
less than 3 stories in height
4. Gravity (nonmotorized) dampers are acceptable in exhaust
and relief outlets in the first story and levels below the first
story of buildings three or more stories in height.
1412.4.2 Optimum Start Controls: Heating and cooling systems with
design supply air capacities exceeding 10.000 cfm shall have optimum
start controls. Optimum start controls shall be designed to automatically
adjust the start time of an HVAC system each day to bring the space to
desired occupied temperature levels immediately before scheduled
occupancy. The control algorithm shall. as a minimum. be a function of the
difference between space temperature and occupied setpoint and the
amount of time prior to scheduled occupancy.
1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include
microprocessor controls that minimize supplemental heat usage during
start -up. set -up, and defrost conditions. These controls shall anticipate
need for heat and use compression heating as the first stage of heat.
Controls shall indicate when supplemental heating is being used through
visual means (e.g.. LED indicators).
1412.6 Combustion Heating Equipment Controls: Combustion heating
equipment with a capacity over 225,000 Blu /h shall have modulating or
staged combustion control.
Exceptions.
1. Boilers.
2. Radiant Heaters
1412.7 Balancing: Each air supply outlet or air or water terminal device
shall have a means for balancing, including but not limited to, dampers,
temperature and pressure test connections and balancing valves
1413 Air Economizers
1413.1 Operation: Air economizers shall be of automatically modulating
outside and return air dampers 10 provide 100 percent of the design supply
air as outside air to reduce or eliminate the need for mechanical cooling.
Water economizers shall be capable of providing the total concurrent
cooling load served by the conneted terminal equipment lacking airside
economizer, at outside air temperatures of 45 °F dry - bulb /40 °F wet -bulb
and below. For this calculation. all factors including solar and internal load
shall be the same as those used for peak load calculations, except for the
outside temperatures
Exception: Water economizers using air - cooled heat rejection
equipment may use a 35 °F dry -bulb outside air temperature for
this calculation. This exception is limited to a maximum of 20 tons
per building.
1413.2 Documentation: Water economizer plans submitted for approval
shall include the following information:
1. Maximum outside air conditions for which economizer is sized to
provide full cooling.
2. Design cooling load to be provided by economizer at this outside
air condition.
3. Heal rejection and terminal equipment performance data
including model number. flow rate. capacity. entering and leaving
temperature in full economizer cooling mode.
1413.3 Integrated Operation: Air economizers shall be capable of
providing partial cooling even when additional mechanical cooling is
required to meet the remainder of the cooling load
Exceptions:
1. Individual, direct expansion units that have a rated capacity
less than 65,000 Btu /h and use nonintegrated economizer
controls that preclude simultaneous operation of the
economizer and mechanical cooling.
2. Water - cooled water chillers with waterside economizer.
1413.4 Humidification: If an air economizer is required on a cooling
system for which humidification equipment is to be provided to maintain
minimum indoor humidity levels. then the humidifier shall be of the
adiabatic type (direct evaporative media or fog atomization type).
Exceptions:
1. Health care facilities where WAC 246 - 320 -525 allows only
steam injection humidifiers in ductwork downstream of final
filters. 1412.6 Combustion Heating Equipment Controls.
Combustion heating equipment with a capacity over 225,000
Btu /h shall have modulating or staged combustion control.
2. Systems with water economizer
3. 100% outside air systems with no provisions for air
recirculation to the central supply fan.
4 Nonadiabatic humidifiers cumulatively serving no more than
10% of a building's air economizer capacity as measured in
cfm. This refers to the system cfm serving rooms with stand
alone or duct mounted humidifiers.
1414 Ducting Systems
1414.1 Sealing: Duct work which is designed to operate at pressures
above 1/2 inch water column static pressure shall be sealed in accordance
with Standard RS -18. Extent of sealing required is as follows:
1. Static pressure: 1/2 inch to 2 inches; seal transverse joints_
2. Static pressure: 2 inches to 3 inches, seal all transverse joints
and longitudinal seams.
3. Static pressure: above 3 inches; seal all transverse joints,
longitudinal seams and duct wall penetrations.
Duct tape and other pressure sensitive tape shall not be used as the
primary sealant where ducts are designed to operate at static pressures of
1 inch W.C. or greater
1414.2 Insulation: Ducts and plenums that are constructed and function
as part of the building envelope, by separating interior space from exterior
space. shall meet all applicable requirements of Chapter 13. These
requirements include insulation installation, moisture control, air leakage,
and building envelope insulation levels. Unheated equipment rooms with
combustion air louvers must be isolated from the conditioned space by
insulating interior surfaces to a minimum of R -11 and any exterior
envelope surfaces per Chapter 13. Outside air ducts serving individual
supply air units with less than 2.800 cfm of total supply air capacity shall be
insulated to a minimum of R -7 and are not considered building envelope.
Other outside air duct runs are considered building envelope until they,
1. connect to the heating or cooling equipment, or
2 are isolated from the exterior with an automatic shut -off damper
complying with Section 1412.4.1.
Once outside air ducts meet the above listed requirements, any runs
within conditioned space shall comply with Table 14 -5 requirements.
Other ducts and plenums shall be thermally insulated per Table 14 -5
Exceptions:
1. Within the HVAC equipment.
2 Exhaust air ducts not subject to condensation
3. Exposed ductwork within a zone that serves that zone.
1415 Piping Systems
1415.1 insulation: Piping shall be thermally insulated in accordance with
Table 14 -6.
Exception: Piping installed within unitary HVAC equipment.
Water pipes outside the conditioned space shall be insulated in
accordance with Washington State Plumbing Code (WAC 51 -26)
1416 Completion Requirements (Refer to NREC Section 1416 and the
Building Commissioning Guidelines, published by the Building
Commissioning Association, for complete text and guidelines for building
completion and commissioning requirements )
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http:/lwww.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -01576
Initials: WER
User ID: 1655
Payee: SIGN -TECH ELECTRIC LLC
Payment Date: 05/12/2008
Total Payment: 1,255.20
SET ID: 05 -12 SET NAME: SIGN TECH
SET TRANSACTIONS:
Set Member Amount
EL07 -197 213.20
7EIIQ-8=3"6.477 500.80
EL08 -197 541.20
TOTAL: 1,255.20
TRANSACTION LIST:
Type Method Description Amount
Payment Check 5779
ACCOUNT ITEM LIST:
Description
TOTAL:
1,255.20
1,255.20
Account Code Current Pmts
ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,255.20
TOTAL: 1,255.20
2338 05/13 9711 TOTAL 1255.20
•
AR
March 25, 2008
City of Tukwila
6300 Southcenter Blvd
Tukwila, WA 98188
RE: Gymboree
Westfield Southcenter
Project No. 080078
To Whom It May Concern:
•
SION
I N C 0 R P O R A T E D
S A I N T L O U I S / D A L L A S
ARCM FCTURE • ENGINLLRINC1 • STORE PLANNING
This letter is in response to changes to the approved permitted drawings for the above project.
If you have any questions, comments or need any additional information regarding this letter
please contact Greg Winchester at ArcVision Inc. 800 - 489 -2233.
A0.0 Revised landlord contact info.
A0.1 Added rear door signage to door hardware schedule.
Revised ceiling spec for stockroom.
Updated ceiling information on responsibility schedule.
A2.1 Revised floor plan keyed note 4A & 16.
Updated partition legend for extent of gypsum board.
A3.1 Added ceiling to stockroom and revised sales ceiling to gypsum board.
Added landlord notes.
A4.1 Revised elevations to indicate gypsum ceiling and ceiling in stockroom.
A5.1 Revised spec for reveal.
A5.2 Revised spec for reveal.
Added note for gypsum board and tenant side of mall bulkhead.
A5.3 Revised spec for reveal.
Indicated fire retardant plywood on details 2 & 3.
A6.1 Added seismic ceiling detail #9 & revised detail 5.
Added or revised details 3 & 6 for gypsum board.
A6.2 Revised gypsum board height on detail 3 & added note to detail 8.
A6.4 Indicated gypsum board ceiling on detail 4.
[1.1 Added power general notes 22 -24 & revised height on keyed note #8.
E2.0 Revised lighting keyed notes 1, 2 & 3.
Added emergency lighting in restroom.
E3.0 Revised light D1.
E4.0 Revised power riser diagram & revised panel schedule HV.
E5.0 Revised spec section 16201.
1950 Craig Rd. - Suite 300 • St. Louis, MO 63146 • Phone (314) 415 -2400 • Fax (314) 415 -2300
M1.0 Revised ceiling in sores to gypsum board.
M2.0 Added landlord notes.
M2.1 Added landlord notes.
Sincerely,
Greg Winchester
Project Manager
CC: File
Arc Vision Inc.
1950 Craig Rd. - Suite 300 • St. Louis, MO 63146 • Phone (314) 415 -2400 • Fax (314) 415 -2300
OPERMIT COORD COPY 41/
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -164 DATE: 04 -01 -08
PROJECT NAME: GYMBOREE
SITE ADDRESS: 1066 SOUTHCENTER MALL
Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
X Revision # 1 BEFORE Permit Issued
DEPARTM NTS: {
" (J ^ V/
Bu ■• ng vision
Public Works
Fire Prevention n Planning Division
Structural
Permit Coordinator
n
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 1111 Incomplete
Comments:
DUE DATE: 04 -03 -08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUT NG:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved n Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 05 -01-08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
OAERMIT COORD COPY a
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -164 DATE: 02 -19 -08
PROJECT NAME: GYMBOREE
SITE ADDRESS: 1066 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPA��jjRTM����EN�� fS: 3 t°t' Bui�dTng vivision
Public Works
Fire Prevention n Planning Division
Structural
Permit Coordinator
n
El
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 14 Incomplete
Comments:
DUE DATE: 02-21-08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 03-20 -08
Not Approved (attach comments) n
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents routing slip.doc
2 -28 -02
PROJECT NAME:
SITE ADDRESS:
Vowedtt-t
1 � L•t YC L M%i V-
•
PERMIT NO:
ORIGINAL ISSUE DATE:
REVISION LOG
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
1
- 01 • -w�-
_V
Summar_y of Revision: ( G 1 ()VD If'✓i2 N a „,-
, r
..,,ti, (I ic, 4t2� I N _ ,G� -5(b( 1ft43}----'
eceived by:
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
REVISION
NO.
DATE RECEIVED
STAFF
INITIALS
ISSUED DATE
STAFF
INITIALS
Summary of Revision:
Received by:
(please print)
• •
City of Tukwila
Steven M. Mullet, Mayor
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
Steve Lancaster, Director
REVISION SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date: SI z81 O g
El
Plan Check/Permit Number: e% 0$ - �G 4
Response to Incomplete Letter #
❑ Response to Correcti Letter #
[ Revision # :E .!!!' ennit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
RECEIVED
errs OF TUKWIlA
APR 01 2008
PERMIT CENTEM
Project Name: r- mkop<'ee_
Project Address: (O exes - 'rrpbMr f c _ S c cv V7_,l0
Contact Person: ' .--,N e\Sen Phone Number: cg IS1+1-Ci21
Summary of Revision: rev: iNnk■Y19
pQY\e\ c4-V\Pc\ u l e _. (Se QF�a -c-1 eci
Sheet Number(s): El . I t E2.0, -6..3.0, E1# .0 t ES.
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
1K-- Entered in Permits Plus on O111, Q (r 4 t7bb
\ applications \fonns - applications on linc\revision submittal
Created: 8 -13 -2004
Revised:
Look Up a Contractor, Electrii or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
SIGNTEL988BG
Licensee Name
SIGN -TECH ELECTRIC LLC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
602152490
Ind. Ins. Account Id
Business Type
LIMITED LIABILITY COMPANY
Address l
5113 PACIFIC HWY E #12
Address 2
City
FIFE
County
PIERCE
State
WA
Zip
98424
Phone
2539222146
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
1/7/2002
Expiration Date
1 /7/2010
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
MORRIT *943K6
Electrical Administrator Information
License
MORRIT *943K6
Name
MORRISON, TRAVIS
Status
ACTIVE
Business Owner Information
Name
Role
Effective
Date
Expiration
Date
MENDENHALL, JOHN
C
PARTNER/MEMBER
01/07/2002
MENDENHALL,
LINDA D
PARTNER/MEMBER 01/07/2002
•
Page 1 of 2
https: // fortress .wa.gov /1ni/bbip /printer.aspx ?License= SIGNTEL988BG 05/12/2008
4
1
J
1
_J
L
A -28
I A -3
i
r CONDUIT TO
TELEPHONg
TERMINAL BD�
A -32
A -26
HV -2/4/6
411rrrrrrrrrrrrrrWi1 -"i.d rrrrrrrrrrrr. �rrrrrrrrirrrrrrrrrrrrrrrrrrrrrrrrrA► rrrrrrrri.. rrrr��rrirrrrrrrrrrrrririrrrrrrrrrrrrrrrrrrI
A -30
044"
A.F.F.
APPROVED PI "^".71 c �rnir, A'flric Cu111 ti
I` •,4 "'" �': �4 "'L'E D, MODIFIED CRALTERED
WI rHOUT AUTHORIZATION FROM THE 8UIwING
Or I' .^ L, ALL WORK SHALL BE DONE 1f4
ACCUR^!I,NCE WITH THE APPROVED PLANS AND
IS I •::.T 10 FIELD INSPECTIONS
FILE
Permit No.
PIar review approval is subject to errors and omissions.
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Fiel and conditio is wedged:
By --�
Date:,
City of Tukw is
BUIR OINP DNISION
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal • •
and may include additional plan review fees.
OPY
SEPARATE PERMIT
REQUIRED FOR:
Fe Mechanical
❑ Electrical
GIumbing
as Piping
City of Tukwila
Lptill DING DIVISION
Public Works, Bulling Divisiptt
PERMIT NUMBER
REVED FOR
COMPLIANCE
CODE
NFPA 70 - NEC
MAY -2 2lO8
(r
City Of Tukwila
BUILDING DIVISION
TYP)
REV1SIO\
NOTE
SEE ARCHITECTURAL DRAWINGS FOR
EXACT MOUNTING HEIGHTS OF ALL
DEVICES.
NOTE
SEE SHEET E1.1
FOR POWER GENERAL NOTES
AND POWER CODED NOTES.
VERIFY ALL CONDONS IN FIELD PRIOR TO BIDS.
SEE ELECTRICAL RESPONSIBILTY SCHEDULE ON SHEET E5.0
POWER PLAN
RECEIVED
CITY OF TUKWIL4
APR 01 2008
PERMIT CENTER
1/4 " =1'-Q"
1
GYMBOREE CORPORATION
500 HOWARD STREET
SAN FRANCISCO, CALIFORNIA 94105
FREDERICK J. GOGLIA
ARCHITECT, NCARB, ISP
t950 CRAIG ROAD, SURE 300 Si. LOUIS, MO 63146
PR (314) 415 -2400 FAX (314) 415-2330 www.ercv.com
W l
I
m CO
C
W
0
DATE I PROJECT INFORMATION:
2
ili a
W 2
J
Ce W m
W ce co
0 �,. I— Co
Z Z
CC tj _
E I-
I— o
. ce
>-: U I
CD (i) LO
csa
T I-
1
w
5-n
(1)
O CO
v v
C••1
r r
N N
100% CHECKSET
v
ISSUE TO PERMIT, BID &
7 777-777
POWER
PLAN
SHEET NUMBER:
E1.0
FILE COPY
1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE
SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DMSIONS OF WORK
AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE
WORK OF ALL SUBCONTRACTORS WITH ALL DMSIONS OF WORK. IT IS
THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL
SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS.
2. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR
CLARITY. CIRCUITING SHALL BE "IHRU- WIRING' WHERE AND WHENEVER
POSSIBLE.
3. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF
ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO
ORDERING RELATED ELECTRICAL EQUIPMENT.
4. ALL RECEPTACLE CIRCUITS UP TO 100' -0' SHALL UTIIZE #12 CONDUCTORS
MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101' -0' TO 150' -0' IN LENGTH
SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS
151' -O' UP TO 250' -0' IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM.
CIRCUITS ABOVE 251' -O' SHALL UTILIZE #6 CONDUCTORS MINIMUM.
5. PLACEMENT OF ALL RECEPTACLES IN THE 'SALES' AREA SHALL BE
INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT
TO CORNERS). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE
LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH
GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH -IN. RECEPTACLES
MOUNTED IN SLAT WALL SHALL BE MOUNTED VERTICALLY AND CENTERED
EVENLY BETWEEN SLAT WALL GROOVES.
6. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS
REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM.
7. WHERE DRYWALL CEIUNGS ARE USED IN THE 'SALES' AREA, THE
ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE
OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION
BOXES ABOVE DRYWALL CEIUNGS SHALL BE UMITED TO LOCATIONS
NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES
OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH
GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY
CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEIUNGS ARE ACCEPTABLE.
8. EQUIPMENT LABELED 'GENERAL ELECTRIC' SHALL BE FURNISHED BY GYMBOREE
AND INSTALLED BY THE ELECTRICAL CONTRACTOR. REFER TO CODED
NOTES, ELECTRICAL RESPONSIBILITY SCHEDULE, PANEL SCHEDULE AND
POWER RISER DIAGRAM FOR SPECIFIC EQUIPMENT DESCRIPTION.
9. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE
LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT
THE LOCATION AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT
ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL
CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR
AND INCLUDE THE COST AS A SEPARATE UNE ITEM IN THE BID. NO
ADDITIONAL MONIES SHALL BE AWARDED FOR 11E-IN REQUIREMENTS TO
A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME
OF THE BID, WITHOUT A SEPARATE UNE REM FOR THE FIRE ALARM
SYSTEM AT THE TIME OF THE BID.
10. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT
SWITCH IN LANDLORD'S SWITCHGEAR WITH DEMISED PREMISES' SPACE
NUMBER.
11. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO
ROOF DECK.
12. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN
PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY
WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY
LANDLORD'S CONTRACTOR AT TENANTS ELECTRICAL CONTRACTOR'S
EXPENSE.
13. RECEPTACLES, VIDEO JUNCTION BOXES AND TELEPHONE OUTLETS SHALL
BE MOUNTED HORIZONTALLY AT 18' A.F.F. UNLESS NOTED OTHERWISE.
14. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CLEAR CHILD-
PROOF COVERPLATES ON ALL RECEPTACLES.
15. ELECTRICAL CONTRACTOR IS TO CUT FLOOR (CORE DRILL ON ELEVATED
FLOORS) AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND
PATCH FLOOR TO MATCH EXISTING. COORDINATE ALL WORK WITH
LANDLORD PRIOR TO STARTING WORK.
16. TELEVISION SETS, VIDEO RECORDERS, SPEAKERS AND COAXIAL CABLES
WILL BE FURNISHED BY GYMBOREE AND WILL BE DELIVERED TO THE JOB
SITE DURING THE CONSTRUCTION PERIOD. ELECTRICAL CONTRACTOR IS
TO FURNISH AND INSTALL ALL NECESSARY CONDUITS, WIRING, JUNCTION
BOXES, ETC. AS REQUIRED TO PROVIDE A COMPLETE AND FUNCTIONAL
SYSTEM. VERIFY PROPER OPERATION OF ALL EQUIPMENT PRIOR TO
TURNING SYSTEM OVER TO GYMBOREE.
17. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL TYPEWRITTEN
PANEL DIRECTORIES IN ALL PANELBOARDS.
18. RECEPTACLES LOCATED IN 'GWB' SHALL BE WHITE WITH WHITE
COVERPLATES. RECEPTACLES LOCATED IN SLATWALL SHALL BE GRAY
WITH SILVER COVERPLATES.
19. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A POLY PULL
STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. SECURE PULL STRING
AT BOTH ENDS OF CONDUIT.
20. ELECTRICAL CONTRACTOR IS NOT TO SHARE THE NEUTRAL CONDUCTOR
OF A CIRCUIT CONTAINING A 'GFCI' DEVICE WITH ANY OTHER CIRCUIT.
21. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN
THE UTILITY CORRIDOR FOR TENANTS USE. NO CONDUIT WILL BE
PROVIDED. LANDKORD WILL PROVIDE A COMMUNICATIONS TERMINAL
BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT G.C.
SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE
SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE
COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL. BE CONTAINED
WITHIN THE TENANT'S SPACE. TENANT G.C. SHALL PROVIDE PLENUM
RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S
TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES U11UZING
THE LANDLORD SUPPUED CABLE TRAY. ANY CORRIDOR WALL
PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED.
POWER GENERAL NOTES
22. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION
BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN
CONNECTION THEIR INDMDUAL FIRE ALARM SYSTEMS OR
COMPONENTS. TENANT G.C. SHALL FURNISH AND INSTALL ALL
NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND
CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION.
TENANT G.G. SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE
ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL
CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT G.C.'S
EXPENSE. TENANT G.C. SHALL USE ONLY LANDLORD'S DESIGNATED
FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE
COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF
FIRE ALARM DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE
MARSHAL'S OFFICE.
23. TENANT G.C. SHALL FURNISH AND INSTALL DUCT DETECTORS WITH
REMOTE TEST SWITCH AND LED INDICATOR UGHTS IN SUPPLY AND
RETURN MAINS FOR EACH TENANT VAV UNIT AS REQUIRED BY CODE
AND LOCAL AUTHORITY HAVING JURISDICTION.
24. TENANT G.C. TO PROVIDE 'CALL FOR AID' SYSTEM IN HANDICAP
TOILET ROOM. COORDINATE WITH LANDLORD FOR REQUIREMENTS.
REVIEWED FOR
CODE ACOMPLIANCE
NEC E
NFPA
- 2008
City -Of TUkWI1d
BUILDING DIVISION
POWER CODED NOTES
0
DUPLEX RECEPTACLES (AT 6' O.C.), QUADRAPLEX RECEPTACLE, DATA
OUTLET AND TELEPHONE OUTLET IN WALL AT 2' -0" A.F.F.. VERIFY EXACT
LOCATION IN FIELD TO CLEAR 'SAFE'.
�2 RECEPTACLES AND COVERPLATES DESIGNATED 'SF' SHALL BE MOUNTED
ON THE UNDERSIDE OF THE STOREFRONT SOFFIT WITH THE 4' SIDE
PARALLEL TO THE STOREFRONT GLASS.
�3 ONE 1 1/4' RIGID GALVANIZED STEEL CONDUIT FOR POWER AND TWO 1
RIGID GALVANIZED STEEL CONDUITS FOR TELEPHONE /DATA
UNDERFLOOR FROM CASHWRAP TO NEARBY WALL, UP WALL TO ABOVE
CEILING AND TO ELECTRIC PANEL OR TELEPHONE TERMINAL BOARD AS
LABELED. STUB CONDUITS UP 6" ABOVE FINISHED FLOOR AT CASHWRAP.
DUPLEX RECEPTACLES (AT 6' O.C.), QUADRAPLEX RECEPTACLE, DATA
OUTLET AND TELEPHONE OUTLET IN WALL AT 2' -0' A.F.F. FOR I.S.S.
EQUIPMENT.
JUNCTION BOX AND DUPLEX RECEPTACLE IN WALL FOR VIDEO MONITOR.
MOUNT JUNCTION BOX AND DUPLEX RECEPTACLE IN WALL AT 24' A.F.F..
INSTALL 1' CONDUIT FROM JUNCTION BOX UP IN WALL TO ABOVE
CEILING AND TO NEAREST CEIUNG DIFFUSER FOR FUTURE CABUNG BY
OTHERS.
QUADRAPLEX RECEPTACLE IN WALL AT 6' -2' A.F.F. FOR DVD PLAYER.
ELECTRICAL, DATA AND TELEPHONE OUTLET(S) MOUNTED IN
CASHWRAP. COORDINATE EXACT PLACEMENT OF DEVICE
AND WIRE ROUTING IN CASHWRAP WITH MILLWORK
DRAWINGS.
DELIVERY BUZZER SYSTEM PUSHBUTTON W F.F. AND POWER
TRANSFORMER HIGH ON WALL FURNISHED I ' STALLED BY
ELECTRICAL CONTRACTOR. PUSHBUTTON SHALL BE EDWARDS #603 AND
TRANSFORMER SHALL BE EDWARDS #596. CONNECT PUSHBUTTON TO
POWER TRANSFORMER AS REQUIRED.
10
11
13
14
15
16
DELIVERY BUZZER SYSTEM BUZZER MOUNT ON WALL AT 9' -0' A.F.F.
FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. BUZZER TO
BE AN EDWARDS #15- 016~I. CONNECT BUZZER TO POWER TRANSFORMER AS
REQUIRED.
DELIVERY BUZZER SYSTEM BUZZER ABOVE CEILING FURNISHED AND
INSTALLED BY ELECTRICAL CONTRACTOR. BUZZER TO BE AN EDWARDS
#660. CONNECT BUZZER TO POWER TRANSFORMER AS REQUIRED.
DUPLEX RECEPTACLE IN. WALL FOR REFRIGERATOR AND MICROWAVE AT
18' A.F.F..
ELECTRICAL CONTRACTOR IS TO ROUTE POWER/DATA/TELEPHONE
CONDUITS DOWN IN WALL TO BELOW CASHWRAP BASE, STUB OUT
CONDUITS IN BASE AREA AND FLEX BACK UP TO DEVICES IN CASHWRAP.
ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A 100 WATT
SERVICE UGHT WITH SWITCH AND GROUND FAULT DUPLEX RECEPTACLE
AT UNIT. DEVICES ARE TO BE WEATHERPROOF WHEN USED OUTDOORS.
CONNECT TO CIRCUIT AS SHOWN.
2'W X 4'H X 3/4' TELEPHONE BOARD WITH DEDICATED QUADRAPLEX
RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM
GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE
COMPANY. EXTEND 1' TELEPHONE CONDUIT WITH PULLWIRE FROM
SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE BOARD. VERIFY
EXACT LOCATION IN FIELD.
JUNCTION BOX MOUNTED IN WALL AT 6' -2' A.F.F FOR DMX MUSIC SYSTEM
WITH 1 CONDUIT STUBBED TO 13' -0" A.F.F..
SINGLE RECEPTACLE IN WALL AT 12' A.F.F. FOR INSTANTANEOUS WATER
HEATER MOUNTED ON WALL. UNDER SINK.
TIME CLOCK AND UGHTING CONTACTORS ON WALL SEE POWER RISER
ON SHEET "E4.0' FOR ADDITIONAL INFORMATION.
ELECTRICAL EQUIPMENT SEE SHEET '4.0'.
RECEIVED
CITY OF TUKWILA
APR f11 7
ELECTRICAL LEGEND
AU. SYMBOLS DO NOT NECESSARLY APPLY
PERMIT CE
SYMBOL
DESCRIPtnaN
MOUNTING HGT. TO CENTERLINE
UNLESS GTHERVISE NOTED
SYMBOL
DESCRIPTION
MOUNTING HGT. TO CENTRRUNF
UNLESS OTHERVISE NOTED
O
0
0
$4
t
CEILING OUTLET
WALL OUTLET
BLANKED OUTLET
WIRED JJNCTION BOX
CEILING MOUNTED EXIT LIGHT
CEILING MCUNED EXIT LIGHT CUTLET
WALL MID. EXIT UGIT W/ DIRECTIONAL ARROWS
DUPLEX RECEPTACLE. 3 MIRE GRD. TYPE
DUPLEX RECEPTACLE. VREAIIRERPROCF
DUPLEX RECEPTACLE. GROUND FAULT PROTECTED
DUPLEX IRECEPTACLE.ISOLATED GROUND
QUADRAPLEX RECEPTACLE
TOGGLE MICK SINGLE POLE
TOGGLE 51ITCH. DOUBLE POLE
TOGGLE SWITCH. 3-WAY. 4 •WAY
MANUAL MOTOR STAMM WATCH
MAGNETIC MOTOR STARTER
COMBINATION STARTER/SAFETY STITCH
SAFETY SWITCH
ELECTRIC PANEL
MOTOR OUTLET. SINGLE PHASE
MOTOR CUTLET. THREE PHASE
SEE DRAWINGS
SEE DRAWINGS
SEE DRAWINGS
SEE DRAWINGS
18'
18'
18'
18'
18'
48'
48'
48'
48'
AS REQUIRED
AS REQUIRED
AS REQUIRED
8'-D' TO TOP
14
aP
D
D4
0
0
0
7
CV
Lig
■ ■ .r • •
a
0
TELEPHONE OUTLET - 4 so. W/PLASIER RING
PUBUC TELEPHONE OUTLET - 4 SQ. W/PLASTER RING
CABLE TV OUTLET
WAU.BOX - OWMER
DATA CUTLET - 4' SO. W/PLASTER RING
FIRE ALARM BREAK STATION
FIRE ALARM AUDIO/VISUAL SIGNAL DEVICE
W/ ROME INDICATCRRS� DETECTOR
FIRE ALARM WATER FLOW svirrai
FIRE ALARM TAMPER SNITCH
SYSTEM SIAM DETECTOR
SYSTEM PHOTO/HEAT DETECTOR
sTSTEL HEAT DETECTCR (FIXED 1131P.)
FIRE ALARM PANEL
.NNCTION BOX
DUPLEX RECEPTACLE AT STOREFRONT
DELPIERY BUZZER
DEUWRY BUZZER PU5HEUTTON
DELIVERY BUZZER TRANSFORMER
10UL11- CUTLET RACEWAY
CDUNG SPEAKER
TIME CLOCK
UGHTING CONTACTOR
15"
54'
24
4a-
18-
48'
06'
AS REQUIRED
AS REQUIRED
AS REQUIRED
CEILING MID.
CEILING UTD.
CEILING MID.
AS REQUIRED
AS REQUIRED
CEIUNG MID.
AS REQUIRED
54'
AS REQUIRED
AS REQUIRED
CEJUNG MID.
As REQUIRED
AS REQUIRED
08
TER
GYMBOREE CORPORATION
500 HOWARD STREET
SAN FRANCISCO, CALIFORNIA 94105
FREDERICK J. GOGLIA
ARCMTECT, WARS, EP
1950 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146
PH. (314) 415-2400 FAX (314) 415 -2300 www.arcvcom
0
0
DATE 1 PROJECT
Co
N
1
N
100% CHECKSET
ISSUE TO PERMIT. BID & LANDLORD
LANDLORD COMMENTS
1056 SOUTHCENTER MALL
TUKWILA, WA 98188
M
5w
1
(1)
"9/ \ ;:FESTERED
d: CdlGt_IA
; ;> c OF WASHINGTON
POWER
PLAN
SHEET NUMBER:
E1.1
CHAIN HANG
LIGHTS IN
STOCKROOM TO
10' -0' A.F.F..
A 23
A-7
via T/C
MIN
■ ■I■
■■I•
■EM
■ •■
■■■
TYPE
G2
TYPICAL
I2E -4
L /EM
■■■
■ IN
via T5C
NMI
■M■
MINN
MEM
MEN
■■■
8w —c
A -21
■M■
■■■
■N■
■U■
■■■
■■■
A AWW WIWAW 1
REVIEWED
N
C COMP- 70 N° NEC
N
WIA►
City Of TUIWiil R
B ILDING DIVISION
NOTE
SEE ARCHITECTURAL REFLECTED
CEILING PLAN FOR EXACT LOCATION
OF ALL LIGHT FIXTURES.
VERIFY ALL CONDfIlON3 IN FIELD PRIOR TO BIDS.
LIGHTING PLAN
1/4"=V-0"
1
1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE
SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DMSIONS OF WORK
AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE
WORK OF ALL SUBCONTRACTORS WITH ALL DMSIONS OF WORK. IT IS
THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL
SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS.
2. LIGHTING SHALL BE CIRCUTID EXACTLY AS SHOWN ON PLANS.
CIRCUITING SHALL BE "THRU -- WIRING" WHERE AND WHENEVER
POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR
VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION
ARE ACCEPTABLE. UGI-ITING FIXTURES SHALL BE MANUFACTURED TO
ACCOMMODATE "THRU— WIRING'. ANY RELATED COSTS FOR MULTIPLE
CONNECTIONS SHALL BE INCLUDED IN BID.
3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION
AND QUANTITY OF LIGHTING FIXTURES.
4. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF
ALL LIGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY
GYMBOREE. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO ENSURE THE
ADJUSTABIUTY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION
AND AIM THEM.
5. EMERGENCY AND OUT UGHTS SHALL BE INSTALLED AND CIRCUITED PER
THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL
EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH
BATTERY BACKUP (120 /277 VOLT INPUT).
B. ALL LIGHTING CIRCUITS UP TO 100' —O' IN LENGTH SHALL UTILIZE #12
CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 101' -0' TO 150' —O'
IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL LIGHTING
CIRCUITS 151' -0" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS
MINIMUM. CIRCUITS ABOVE 251' -0' SHALL UTILIZE #B CONDUCTORS
MINIMUM.
7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS
REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM.
8. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES' AREA, THE
ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE
OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION
BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS
NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES
OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH
GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH —IN TO AVOID ANY
CONFLICTS. JUNCTION BOXES ABOVE LAY —IN CEILINGS ARE ACCEPTABLE
9. EXIT /EMERGENCY LIGHTS AT STOREFRONT ARE TO BE CEIUNG MOUNTED
AND CENTERED OVER OPENING (`TYPICAL U.N.O.). EXR /EMERGENCY
UGHTS AT DOOR TO "NON— SALES' SHALL BE CENTERED ON WALL ABOVE
DOOR. SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT
LOCATIONS.
10. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A POLY PULL
STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. SECURE PULL STRING
AT BOTH ENDS OF CONDUIT.
PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN NON— VISIBLE
LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN FURNISHED BY
GYMBOREE ELECTRICAL CONTRACTOR SHALL VERIFY EXACT
REQUIREMENTS WITH U.L SECTION 2161 REQUIRING THE USE OF
SECONDARY GROUND FAULT PROTECTION AND INCLUDE ALL COST IN
BID. POWER JUNCTION BOX IS TO BE MOUNTED IN CENTER OF SIGN BOTH
VERTICALLY AND HORIZONTALLY. STOREFRONT SIGNAGE AND LIGHTING
TIMECLOCKS SHALL BE SET TO MALLS OPERATING HOURS.
PROVIDE WALL MOUNTED EMERGENCY LIGHT WffH 90 MIN. BATTERY BACKUP CAPACITY.
SEE SWITCHBANK DETAIL THIS SHEET.
a 0
b
g
❑
0
1
A-27
A -29
A-11
A -13
A -21
A-23
SALES
SALES
SALES
SALES
FLUOR
FLUOR
ACCENT
TRACK
LIGHTING
LIGHTING
LIGHTING
LIGHTING
e
❑
f
❑
g
❑
h
❑
A -25
A-27
A -29
A -31
SALES
SALES
SALES
SALES
TRACK
TRACK
TRACK
TRACK
LIGHTING
, LIGHTING
LIGHTING
LIGHTING
CONTRACTOR TO VERIFY EXACT CONFIGERATION
REQUIRED WITH SPACE AVAILABLE. PROVIDE
LABELS AS DIRECTED BY OWNER. SWITCHES
SHALL NOT BE MOUNTED HIGHER THAN 48"
SWITCH BANK
MR
RECEIVED
CITY OF TUKWILA
APR 012008
PERMIT CENTER
LIGHTING GENERAL NOTES
LIGHTING CODED NOTES
GYMBOREE CORPORATION
500 HOWARD STREET
SAN FRANCISCO, CALIFORNIA 94105
FREDERICK J. GOGLIA
ARCFUTECT, NCARB, ESP
1950 CRAIG ROAD, SURE 300 ST. LOUIS, MO 63146
P14 (314) 415 -2400 FAX (314) 415 -2300 www.ercv.com
W M
m CO
� M
W
1
PROJECT INFORMATION:
1056 SOUTHCENTER MALL
TUKWILA, WA 98188
0)
W
a
h
100% CHECKSET
CO
CV
0
ISSUE TO PERMIT, BID Sc
a
v
I
N
LANDLORD COMMENTS
5..,`- 1 n
�.r.. 11∎NG
WAS TON
LIGHTING
PLAN
SHEET NUMBER:
E2.0
LIGHT FIXTURE SCHEDULE
PA U I
SYMBOL
DESCRIPTION
MANUFACTURER & MODEL NUMBER
HEIGHT
DESCRIPTION
LAMP
WATTAGE
•
Al
B" DIAMETER RECESSED
COMPACT FLUORESCENT
DOWNLIGHT. CLEAR CONE, MATTE
FINISH. ELECTRONIC BALLAST,
SELF FLANGED REFLECTOR
MAXILUME:
HV6PL- 1X32 —E-- 120/277- 6101 —CL
9-1/4-
32 watt, T4, 4Pin
GX24q -3 Base,
Triple Compact
Fluorescent, 3000K,
82 CRI, 10,000 Hrs.
PHILIPS: PL —T 32W/30/4P /ALTO
OSRAM /SYLVANIA: CF32DT/E/IN /830
GE F32TBX/SPX30 /A /4P
36 watts
A1A
6" DIAMETER RECESSED
COMPACT FLUORESCENT
DOWNUGHT. ELECTRONIC CONE, MATTE
FINISH, ELECTRONIC BALLAST,
SELF FLANGED REFLECTOR.
EMERG. BATTERY BACKUP
MAXILUME
HVBPL- 1X32 —E- 120/277— EMG750 -- 6101 —CL
9-1/4"
32 watt, T4. 4Pin
GX24q -3 Base,
Triple Compact
Fluorescent 3000K.
82 CRI, 10.000 Hrs.
PHILIPS: PL —T 32W/30/4P /ALTO
OSRAM /SYLVANIA: CF32DT/E/IN /830
GE F32TBX / / X30 A 4P
36 watts
•
D1
INCANDESCENT RECESSED
DOWNUGHT
HALO:
H7U1CT/3OCAT
'�_���.
9-1/2*
/�
60W A19
PHILIPS: 60A19
OSRAM/SYLVANIA: 60A19
GE 60A19
.� .. �� ..
60 watts
•
F
2' LONG WALL MOUNTED
MIRROR LIGHT
���� —�'
METALUX BC- 217 — UNV —EB81
____
4-1/4'
2- 17watt, T8,
Medium BI—Pin Base,
Linear Fluorescent,
3000K, 82 CRI,
20,000 Hrs.
PHILIPS: F17T8 830
OSRAM/SYLVANIA. F017/830
GE F17T8/SPX30
32 watts
•
G2
2' X 2' RECESSED FLUORESCENT
TROFFER, HIGH BALLAST FACTOR
ELECTRONIC BALLAST, 9 CELL
SEMI— SPECULAR PARABOUC
LOUVER,
SIMKAR: TEP242- 232U- 9C—B11 —UNV
5 3/4"
2-32watt, 113, U6,
Medium BI—Pin Base,
Linear Fluorescent,
3000K, 82 CRI,
20.000 Hrs.
PHILIPS: F32T8/TL830 /ALTO
OSRAM/SYLVANIA F032/830
GE: F32T8/SPX30
62 watts
•
G2A
2' X 2' RECESSED FLUORESCENT
TROFFER, HIGH BALLAST FACTOR
ELECTRONIC BALLAST, 9 CELL
SEMI— SPECULAR PARABOUC
LOUVER. BACK —UP BATTERY
BALLAST
SIMKAR: TEP242- 232U- 9C —B11— UNV —EM
2- 32watt, 18. U6.
Medium BI—Pin Base,
Linear Fluorescent,
3000K, 82 CRI,
20.000 Hrs.
PHIUPS: F32T8/1L830 /ALTO
°SRAM/SYLVANIA F032/830
GE F3218/SPX30
62 watts
H2
2' X 4' RECESSED FLUORESCENT
TROFFER, HIGH BALLAST FACTOR
ELECTRONIC BALLAST, 9 CELL
SEMI — SPECULAR PARABOUC
LOUVER.
SIMKAR: TEP244- 332- 18C —B11 —UNV
3- 32watt, T8
Medium BI—Pin Base,
Linear Fluorescent,
3000K, 82 CRI,
20,000 Hrs.
PHILIPS: F32T8/ 1L830 /ALTO
OSRAM/SYLVANIA F032/830
GE F32T8/SPX30
93 watts
H2A
2' X 4' RECESSED FLUORESCENT
TROFFER, HIGH BALLAST FACTOR
ELECTRONIC BALLAST, 9 CELL
SEMI— SPECULAR PARABOUC
LOUVER, BACK —UP BATTERY
BALLAST
SIMKAR: TEP244- 332- 18C —B11— UNV —EM
3- 32watt, T8
Medium BI—Pin Base,
Linear Fluorescent,
3000K, 82 CRI,
20.000 Hrs.
PHILIPS: F32T8/TL830 /ALTO
OSRAM/S'YL.VANIA F032/830
GE: F32T8/SPX30
93 watts
•
—4'
4' BARE LAMP FLUORESCENT
STRIP, ELECTRONIC LOW BALLAST
FACTOR BALLAST, 1 LAMP IN
SECTION
WIRE GUARD
METALUX: SN132 --UNV
3 1/4
32 Watt. T8, Medium
BI—Pin Base, Linear
Fluorescent, 3000K,
82 CRI, 20,000 Hrs.
PHILIPS: F32T8 ALTO
OSRAM/SYLVANIA F032/830
GE: F32T8 /SPX30
32 watts
U-6'
6' BARE LAMP FLUORESCENT
STRIP, ELECTRONIC LOW BALLAST
FACTOR BALLAST, 1 LAMP IN
SECTION
WIRE GUARD
METALUX 6TSN225 —UNV
3 1/4
2- 25watt, T8,
Medium BI —Pin Base,
�� Fluorescent,
3�OK, 82 CRI,
20.000 Hrs.
PHILIPS: F25T8/830
OSRAM �� -VANIA F025/830
F25T8/SPX30
watts
�_8■
8' BARE LAMP FLUORESCENT
STRIP, ELECTRONIC LOW BALLAST
FACTOR BALLAST. 1 LAMP IN
SECTION. (2) 4' SECTIONS
TANDEM WIRED CM ONE BALLAST,
QUICK CONNECT PLUGS
WIRE GUARD
METALUX 8T5N232 —UNV
3 1/4"
2 -32 Watt, T8,
Medium Bi —Pin Base,
Linear Fluorescent,
3000K, 82 CRI,
20.000 Hrs.
PHILIPS: F32T8/TL830 /ALTO
OSRAM/SYLVANIA F032 /830
GE F32T8/SPX30
62 watts
•
L2E-4'
4' BARE LAMP FLUORESCENT
STRIP, ELECTRONIC LOW
BALLAST FACTOR BALLAST, 1
LAMP IN SECTION■ EMERGENCY
BATTERY BACKUP
WIRE GUARD
MET'41 -UX: SN132— UNV— EMERGENCY
3 1/4 "
32 Watt, T81 Medium
BI —Pin Base, Linear
Fluorescent. 3000rs
82 CRI. 20,000 Hrs.
PHIUPS: F32T8/TL830 /ALTO
OSRAM/SYLVANIA F032/830
F321
31 watts
•
M
TOILET ROOM EXHAUST FAN
AIRZONE PA900 —VL
7 -3/4"
--
—
51 watts
T2
TRACK MOUNTED METAL HALIDE
WALL WASHER
AMERLUX: SOL011 24HOT5E
—
70 WATT MH
PHILIPS: MH70 /C/U/M/3K
70 watts
•
T3
PAR 38 REAR LOADING GiMBAL
RING TRACK HEAD, MATTE
WHITE FINISH
MAXILUME.
10 1/8"
45 watt, PAR38,
Medium Screw Base.
Quartz Halogen Flood
PHILIPS: 45PAR38/NFL
OR: 45PAR/H
PHILIPS: 45PAR /CAP/FL
45 watts
•
TS
SURFACE MOUNTED SINGLE
CIRCUIT TRACK, MATTE WHITE
FINISH
MAXILUME ET2,ET4,ET6,ET8 ETiO1WH
AS REQUIRED
11/16"
—
—
—
•
X1
EXIT SIGN
NAVIUTE NXPB3GWH
—
—
—
2 watts
REVIEWED
CODE COM A
NFPA 70 - NEC
10i -
- C +�Y �f TukWda
B UILDING oMSION
RECEIVED
CITY OF TUKW ILA
APR 01 2008
PERMIT CENTER
LIGHTING FIXTURE SCHEDULE
MEMO
GYMBOREE CORPORATION
500 HOWARD STREET
SAN FRANCISCO, CALIFORNIA 94105
FREDERICK J. G0GLIA
ARCHITECT, NCARB, ISP
1950 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146
PH (314) 415 -2400 FAX (314) 415 -2300 www.ercv.com
W
m CO
ce� M
w �
DATE 1 PROJECT INFORMATION:
LA
1056 SOUTHCENTER MALL
TUKVVILA, WA 98188
x
o
a
100% CHECKSET
ISSUE TO PERMIT, BID &
co
v
11]
N
LANDLORD COMMENTS
STLEED
}, :r ,i €1SHlidr": iV
LIGHTING
FIXTURE
SCHEDULE
SHEET NUMBER:
E3.0
Pend Ming Schedule (wee)
Panelboard A Voltage 120/208 Phase _3_ Wire 4 AIC Rating 10,000
Panel Type AO Mains 100A -3P MCB Mains Rating 225 AMP
NINA Type Enclosure 1 Mounting SURFACE Options Note
Ckt.
Na
Zane
Load Descriptke
Brly
Sze
Brkr
N.E.C.
KW
Actual
KW
Phase
Actual
N.EC.
Brkr
OPth
Sire
Load Description
Zane
Ckt.
Na
1
iVICIER
SPARE
--
0.75
- --
- --
A
0.500
0.500
LO
- --
SECURITY
Q
2
3
T/C
SHOW WIN. REC.
1 50/3
LO
0.360
0.360
B
0.360
0.360
LO
15/3 +
TELEPHONE BD.
- -- *
4
5
T/C
SIGN
- --
LO
1.500
1.500
C
0.360
0.360
LO
7.897
CASH REGISTER
ELECTRIC WATER
HEATER
6
7
T/C
SHOW WIN. LTS.
- --
LO
1.510
1.510
A
0.750
0.750
LO
- --
CASH REGISTER
8
9
TWO CATEGORIES
INSTALLED
OF COMPRESSOR
INCLUDED
= MINIMUM
SHOW WIN. REC.
- --
LO
0.360
0.360
B
0.200
0.200
LO
- --
TIMECLOCK
x
43.2AMPS
10
11
SALES FLOORS.
- --
0.682
0.682
C
- --
- --
- --
SPARE
12
13
SALES FLOORS.
- --
0.496
0.496
A
0.360
0.360
- --
SALES RECEPTS.
14
15
•
SPARE
- --
- --
- --
B
0.360
0.360
- --
SALES RECEPTS.
16
17
NL/EM NS
- --
LO
0.316
0.316
C
- --
- --
- --
SPARE
18
19
SPARE
- --
- --
A
0.720
0.720
CASHWRAP
20
21
SALES ACCENT
1.612
1.612
B
1.800
1.800
LO
MICRO./REFRIG.
22
23
SALES TRACK
1.800
1.800
C
1.500
1.500
LO
I.S.S. RACK
24
25
SALES TRACK
1.350
1.350
A
0.360
0.360
LO
MANAGER'S DESK
26
27
SALES TRACK
1.800
1.800
B
0.460
0.460
NS REC%BUZZER
28
29
SALES TRACK
1.800
1.800
C
0.750
0.750
LO
WATER HEATER
30
31
SALES TRACK
1.200
1.200
A
0.360
0.360
LO
SOUND SYSTEM
32
33
SPARE
- --
- --
B
0.280
0.280
LO
VAV- LT/REC
34
35
SPARE
- --
- --
C
- --
- --
SPARE
36
37
NON -SALES LTS.
0.3.31
0.331
A
0.500
0.500
LO
I.S.S. RACK
38
_
39
SPARE
- --
- --
B
- --
- --
SPARE
40
41
SPARE
- --
- --
C
- --
- --
SPARE
42
Notes
• All circuit breakers to be 20 -Alp, 1-Pole unless otherwise noted.
Zones marked T/C to be routed via trmedodc
Actual Load Totals: OA 8.437 kw N.E.C. Connected Totals: OA_ 5.437 kw
!I13 7.592 jag /B 7.592 lee
dC 8.508 kw iC 8.508 kw
Totd 24.437 kw Totd 24.437 1,
37
(AN Phases to be balanced to within 7X using Actud Load Totds.)
motions:
AS - Poied'edc AS Breaker
LO - Handle Lock -off device
ST - Shunt Trip Type
AUX - Audlary Contacts
PA - Honda Pododc Attodunent
GFCI - Ground Fault Crrait tar
HACR - Heating, A/C & R
Panel Vilrimg Schedule (a-Ph a
Panelboard
Panel Type
NEMA Type Endosure 1
HV
14E
Vdtage 277 /480 Phase _a_ Wire 4
Mains 225A -3P MLO Mains Rating 225 AMP
Mounting SURFACE Options
AIC Rating 14,000
Note
Na
Zone
Load Description
a
•
Opts
N.EG:.
KW
Actual
KW
Phase
Actual
KW
N.E.G.
KW
MOT
Opts
Sze
•
Load Description
Zone
Na
1
iVICIER
120V, 10
--
0.75
8.437
8.437
A
2.498
2.498
- --
- --
9.690
Q
2
3
--
30kva XFMR
1 50/3
LO
7.592
7.592
B
2.498
2.498
LO
15/3 +
VAV-1
- -- *
4
5
- -- *
1.0
- --
8.508
8.508
C
2.498
2.498
HACK
7.897
*
ELECTRIC WATER
HEATER
6
7
0.750
SPACE
- --
0.750
- --
- --
A
- --
- --
-_.-
- --
SPACE
8
9
TWO CATEGORIES
INSTALLED
OF COMPRESSOR
INCLUDED
= MINIMUM
SPACE
- --
VA.
ONLY ON ONE
- --
- --
B
- --
- --
- --
SPACE
x
43.2AMPS
10
_
11
SPACE
- --
- --
- ---
C
--
- --
- --
SPACE
12
13
SPACE
- --
- --
- --
A
- --
- --
- --
SPACE
14
15
SPACE
- --
- --
- --
B
- --
- --
- --
SPACE
16
17
SPACE
- --
- --
- --
C
- --
-----
- --
SPACE
18
Notes
• All circuit breakers to be 20 -Amp, 1 --Pole unless otherwise noted.
Actual Load Tatdx dA 10.835 kw
08_10.921110
4 C 11.006kw
Tot _ 31.931kw
N.E.C. Counted ted Totale dA 10.8351m
08 10.090 kw
!C 11.006ke
Total 31.931Ia1
(All Phases to be balanced to withic 7% using Actud Load Totds.)
EQUIPMENT WIRING SCHEDULE
SYM.
ITEM
VOLTAGE
HP.
KW.
A.
F.L.A.
FEEDERS
YPE OF
CONN.
BRANCH
BREAKER
DISC.
SW.
BUSS
FUSES
REMARKS
WIRE
COND.
0
iVICIER
120V, 10
--
0.75
--
112 Gliti N
1 3/4`
PLUG alt COD
SINGLE
RECEPTACLE
20A-1P
- --
- --
9.690
Q
VAV -1
480V. 30
--
7.5
--
1 12 TR. O
3/4"
DIRECT
15A -3P
HACK
30AS
15AF
--
..__
LANDLORD
• LEASE LINE
GYMBOREE SPACE
40/0 THHN AND 1 #4 GROUND
IN A 2" CONDUIT LANDLORD
PROVIDED AT TENANT G.C.'S
a1'ENSE
600V,2 I I A. 200 A.F.
LANDLORD PROVIDED AT
TENANT G.C.'S EXPENSE
TENANT G.C. TO RELOCA
SWITCH.
Bredcer 0pticns
AS - Pararrrik AS Breaker
LO - Handle Lack -off device
ST - Shunt Trip Type
AUX - &navy Contacts
PA - Hande Padodc Attachment
GFG - Ground Fait Circuit ter
HACR - Heating. A/C &
ROOF
CEILING
LANDLORD'S 277/480V,3PH,4W
DISTRIBUTION SWITCHBOARD.
METER BY LANDLORD AT-
TENANT G.C.'S EXPENSE.
THE LANDLORD -OWNER
NETWORK METERING
SYSTEM WILL METER
TENANT POWER
CONSUMPTION.
443/0 THHN AND 104
GROUND IN A 2" CONDUIT
BY TENANT G.C.'S
SEE
PANEL
SCHEDULE
200A -3P CIRCUIT BREAKER
LANDLORD PROVIDED AT
TENANT G.C.'S EXPENSE.
30 THHN AND 1#10
GROUND IN A 1 -1/4"
CONDUIT BY TENANT G.C.
NOTE
ELECTRICAL CONTRACTOR IS TO COORDINATE
ALL GENERAL ELECTRIC EQUIPMENT, PROVIDED
BY GYMBOREE TO JOB SITE WITH GENERAL
ELECTRIC REPRESENTATIVE LEO ALANES AT
(508) 870 -2402 FOR CORRECTNESS OF
EQUIPMENT ON SITE AND WITH ANY
INSTALLATION QUESTIONS.
POWER RISER
NTS
SEE
PANEL
SCHEDULE
NEW 7 -DAY, 24 -HOUR
ELECTROMECHANICAL TIME CLOCK TORK
#W400.
4#3 THHN AND 1#S GROUND IN
A 1 1/4" CONDUIT BY TENANT
G.C.
6 THHN GROUND TO BUILDING
STEEL BY ELECTRICAL
CONTRACTOR.
NEW 30 KVA STEP -DOWN XFMR.
FLOOR MOUNTED, 480 VOLT,
3- PHASE, 3-WIRE PRIMARY,
120/208 VOLT, 3- PHASE, 4 -WIRE
SECONDARY.
ELECTRIC LOAD SUMMARY 277/01
SYSTEM
DESCRIPTION
ACTUAL
CONNECTED
KW/KVA
POWER
FACTOR
ACTUAL
DEMAND
KVA
N.E.C.
CONNECTED
KW/KVA
N.E.C.
DEMAND
FACTOR
N.E.C.
DEMAND
KVA
LIGHTING
13.997
•
13.997
13.997
1.25
17.496
_
SHOW WINDOW
LIGHTING ALLOWANCE
- --
•
---
*
- -.
1.25
- --
RECEPTACLES
9.690
1.0
9.690
9.690
1.0 1 4G
Q5 REMAINING K KW
9.690
MOTORS
- --
0.9
- --
- --
1.0
+259% LARGEST
..__
FIXED ELECTRIC
SPACE HEATING
- -- *
1.0
- -- *
- -- *
1.0
- --
AIR CONDITIONING
SYSTEM
7.494 *
1.0
7.494 *
7•494 *
1.0 ***
+251; LARGEST
7.897
*
ELECTRIC WATER
HEATER
0.750
1.0
0.750
0.750
1.0
0.750
MISCELLANEOUS
-__
1.0
-_-
-_.-
1.0
---
TOTAL
NOTES
31.931
TWO CATEGORIES
INSTALLED
OF COMPRESSOR
INCLUDED
= MINIMUM
31.931
31.931
VA.
ONLY ON ONE
35.833
VALUE OF THE
220-12 REQUIREMENT
MINUS ACTUAL
MOTOR
IS ALREADY
KVA 1..1000
(200VA PER FOOT OF
SHOW WINDOW LIGHTING
IN SYSTEM. APPLIED
IN LIGHTING LOAD.
FEEDER AMPERAGE
UNIT.
* USE GREATER
** N.E.C. ARTICLE
SHOW WINDOW)
*** 125% OF THE LARGEST
• POWER FACTOR
N.E.C. DEMAND
SYSTEM VOLTAGE
35.833 x 1000
x
43.2AMPS
=
480 x 1.73
NOTES
1. ALL PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, MANUAL
MOTOR STARTERS, MAGNETIC STARTERS, LIGHTING CONTACTORS,
CIRCUIT BREAKERS IN NEMA ENCLOSURES. ETC. ARE TO BE
MANUFACTURED BY GENERAL ELECTRIC AND FURNISHED BY GYMBOREE
TO THE PROJECT FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR.
2. ALL NECESSARY FUSES ARE THE RESPONSIBILTY OF THE ELECTRICAL
CONTRACTOR TO FURNISH AND INSTALL. SEE EQUIPMENT WIRING
SCHEDULE AND POWER RISER FOR FUSE SIZES.
3. ALL TRANSFORMERS ARE TO MANUFACTURED IN COMPLIANCE WITH
NEMA TP -1 STANDARDS.
RECEIVED
CITY OF TUKVUILA
APR 01 2008
PERMIT CENTER
ELECTRICAL SCHEDULES AND POWER RISER
CYKNE300
GYMBOREE CORPORATION
500 HOWARD STREET
SAN FRANCISCO, CALIFORNIA 94105
FREDERICK J. GOGLIA
ARCHITECT, NCARB, ISP
1950 CRAIG ROAD, SUITE E 300 ST. LOUD, HO 63148
PH (314) 415 -2400 FAX (314) 415 -2300 www.ercv.com
w M
m wCO
M
w
PROJECT INFORMATION:
100% CHECKSET
ce
0
ISSUE TO PERMIT, BID &
•
J
2
xco
Hco
Z co
M
of
(0
cD
r I-
an
0
oc17 ;- ?EGISTERED
� ' 'WASHINGTON
ELECTRICAL
SCHEDULES AND
POWER RISER
SHEET NUMBER:
E4.0
3
DIVISION 16000 - ELECTRICAL
SECTION 16001 - BASIC ELECTRICAL REQUIREMENTS
A. GENERAL CONDITIONS
1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING
GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER
SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF
DIVISION 16000.
2. THE CONTRACTOR FOR THIS DIVISION OF WORK I5 REQUIRED TO READ
THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF
WORK AND I5 RESPONSIBLE FOR THE COORDINATION OF THEIR WORK
AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DIVISIONS OF
WORK. IT IS THIS CONTRACTORS RESPONSIBIUTY TO PROVIDE THEIR
SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS.
3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION
AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR
SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT
COMPLETION DATE.
4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO
DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE
NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED
SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUAUFIED IN THE
CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF
KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH
ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE
CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK.
5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO
RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID.
SECTION 16002 - GENERAL REQUIREMENTS
1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT,
SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS
NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN
ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS
REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS
BEING BY THE LANDLORD OR GYMBOREE SHALL BE PROVIDED BY THE
ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE
INSTALLATION WITH THE LANDLORD AND THE GYMBOREE PROJECT
MANAGER, AS REQUIRED.
2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT
EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL
BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY
MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER
SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS,
BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND
WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL
BE FURNISHED AND INSTALLED AS PART OF CONTRACT.
3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH
EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE
CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE
SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND
DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED
OTHERWISE.
4. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY
ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING.
THIS CONTRACTOR I5 RESPONSIBLE FOR PROVIDING ACCESS PANELS FOR
SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT.
5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER
USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES.
6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND
EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW,
UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN
CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES,
WHICHEVER IS MORE STRINGENT.
SECTION 16003 - CODES
1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S,
COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND
HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER
APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL
INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES,
AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES
REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT
INCLUDED IN THE BID, THEY MUST BE QUAUFIED AS A SEPARATE LINE
ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST
DUE TO CODE ISSUES SHALL BE REIMBURSED BY GYMBOREE TO THE
CONTRACTOR.
SECTION 16004 - LICENSES, PERMITS, INSPECTIONS & FEES
1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS,
INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK.
2. FURNISH TO GYMBOREE'S PROJECT MANAGER ALL CERTIFICATES OF
INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF
PROJECT.
SECTION 16005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS
1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE
DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE
USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED
AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE
SUBJECT TO APPROVAL IN WRITING BY GYMBOREE'S PROJECT MANAGER
THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE.
THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO
REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE.
2. ELECTRICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION
REQUESTS TO GYMBOREE'S PROJECT MANAGER FOR APPROVAL
SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW
FOUR (4) WORKING DAYS FOR GYMBOREE'S PROJECT MANAGER'S REVIEW
WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS.
SUBMITTALS SHALL BEAR THE STAMP OF GENERAL CONTRACTOR AND
THE SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND
CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE
CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE
EXCEPTIONS HAVE BEEN TAKEN.
SECTION 16006 - GUARANTEE
1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK
PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR
REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR
EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12
MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE
INSTALLATION BY GYMBOREE'S PROJECT MANAGER. EXTENDED
WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT.
2. GYMBOREE SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL
PARTS ON EQUIPMENT PROVIDED BY GYMBOREE AND GYMBOREE'S
VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL
WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO
ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID.
SECTION 16007 - RECORD DRAWINGS
1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE
JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS:
A. LOCATION OF CONCEALED CONDUIT AND WIRING.
B. LOCATION OF JUNCTION BOXES.
C. REVISIONS, ADDENDUMS, AND CHANGE ORDERS.
D. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD
CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND
CONTRACTOR'S COORDINATION WITH OTHER TRADES.
2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE
CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND
CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE
COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE
CONTROL DRAWINGS INCLUDED SHALL BE DEUVERED TO GYMBOREE'S
PROJECT MANAGER.
SECTION 16008 - DISCREPANCIES IN DOCUMENTS
1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC
AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL
SYSTEM. WHERE DRAWINGS, EXISTING SITE CONDITIONS,
SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE
GYMBOREE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO
CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE,
GYMBOREE'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT
DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL
COMPENSATION PERMITTED.
SECTION 16009 DEMOLITION
1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF
THE DEMOLITION OF EXISTING WORK AND THE DEMOUTION PROVIDED
BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL
CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT.
2. ELECTRICAL CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE
GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING UGHT
FIXTURES, RECEPTACLES, SWITCHES, ETC. NOT BEING REUSED ON THIS
PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST
VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT
PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE
ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND
ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE.
EXISTING ABANDONED CONDUITS OR EQUIPMENT IN THE FLOOR,
EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT
OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY
ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR
CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN.
CONFIRM THE EXTENT OF DEMOUTION WITH THE GENERAL CONTRACTOR
AND GYMBOREE PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS
DIRECTED BY THE GENERAL CONTRACTOR AND GYMBOREE. ALL UNUSED
EXISTING PLENUM RATED CABLING IS TO BE REMOVED COMPLETELY.
SECTION 16010 - CUTTING AND PATCHING
1. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS
REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS
SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED
WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR
ENGINEER.
2. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND
FINISH AND SHALL MATCH ACCURATELY ALL SURROUNDING
CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND
GYMBOREE'S PROJECT MANAGER.
3. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE
CONSTRUCTION PERIOD, WHETHER OR NOT DUE TO THE CONTRACTOR'S
NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR
AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND
GYMBOREE'S PROJECT MANAGER.
SECTION 16011 - SLEEVES
1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR
FACIUTIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND
THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE
CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE
FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST
COORDINATE THROUGH THE LANDLORD ANY CORE DRILUNG OR
CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS.
2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR
FLOORS SHALL BE ARE SEALED WITH CALCIUM SIUCATE, SIUCONE "RTV"
FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR
FIRE RATING.
3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS
SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH
EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED
CEIUNGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO.
22 U.S.G. GALVANIZED STEEL MINIMUM.
SECTION 16012 - HANGERS
1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE
IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER
RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK.
2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR
MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK I5 NOT
PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR
JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT
CONDUIT OR BOXES, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE
HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT
INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER
EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO
SUBJECT TO LANDLORD CRITERIA.
DIVISION 16200 - ELECTRICAL
SECTION 16201 - SUMMARY OF WORK
A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT,
ETC. NECESSARY FOR REASONABLY IMPLIED AND INCIDENTAL TO THE
FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE
WORK FOR THE ELECTRICAL SYSTEM AS CALLED FOR IN THE
SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE,
N
T
T
F
1. NO WORK EXCEPT FOR INSTALLATION OF NAMEPLATE SHALL BE DONE
IN LANDLORD'S ELECTRICAL /METER ROOMS.
. COMPLETE POWER AND LIGHTI r . UTION SYSTEMS INCLUDING
ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM.
3. COMPLETE LIGHTING FIXTURE INSTALLATION.
4. COMPLETE TELEPHONE CONDUIT SYSTEM, INCLUDING SERVICE CONDUIT
FROM POINT OF CONNECTION TO LANDLORDS SYSTEM AND ALL
TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC..
5. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION.
6. WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS,
FURNISHED BY THE OWNER.
7. PROVISIONS FOR FIRE ALARM /SMOKE EVACUATION SYSTEM AND
EXTENSION TO LANDLORDS SYSTEM (IF APPLICABLE).
8. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION.
9. TESTING OF ALL ELECTRICAL EQUIPMENT.
10. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF
PROJECT CLOSE -OUT.
B. PROVIDE ELECTRICAL SERVICE AS INDICATED ON THE DRAWING. ALL
WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE
POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL
CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE
LANDLORD AND THE POWER COMPANY. CONTRACTOR SHALL MAKE
ARRANGEMENTS WITH THE LOCAL UTILITY COMPANY FOR INSTALLATION
OF METERING AS REQUIRED BY THE LANDLORD.
C. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL
TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT
SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL
BE PROVIDED WHERE REQUIRED FOR UTIUTY COMPANY WIRES.
COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL
CONDUIT (IF REQUIRED BY LANDLORD OR LOCAL CODE) FOR TELEPHONE
SYSTEM WITHIN THE LEASED SPACE. OUTLET BOXES SHALL BE 4"
SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE.
D. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM
ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE
AND FINISHED INSTALLATION.
SECTION 16202 -- MATERIALS
A. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS
THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE
UNDERWRITER'S LABORATORY UST OF APPROVED ITEMS AND SHALL
MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS.
B. CONDUIT SHALL BE STANDARD STEEL, IMC OR EMT (THIN WALL)
ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED
IN FINISHED AREAS. EXCEPT AS OTHERWISE APPROVED BY GYMBOREE'S
PROJECT MANAGER. EMT CONNECTIONS SHALL BE COMPRESSION TYPE.
MINIMUM SIZES OF CONDUIT SHALL BE 3/4 ", EXCEPT 1/2" FOR SWITCH
LEGS. EMT SHALL BE GALVANIZED OR ELECTRO- GALVANIZED. EMT
SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE THE
SUSPENDED CEIUNG OR CONCEALED IN INTERIOR PARTITIONS. EMT
SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS USE
IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH SCREW
CONNECTIONS. FLEXIBLE METAWC TUBING MAY BE USED IN LIEU OF
EMT FOR CONCEALED BRANCH CIRCUIT WIRING ONLY, WHERE
PERMITTED BY LOCAL AUTHORITIES. FLEXIBLE METAL CONDUIT MAY BE
USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT,
PERMITTED BY CODE.
C. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600
VOLT INSULATION:
1. #10 AND SMALLER - SOLID. #8 AND LARGER - STRANDED. MINIMUM WIRE
SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL
APPUCATIONS.
2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE
SITE IN UNBROKEN PACKAGES.
3. GENERAL WIRING SHALL HAVE THHN INSULATION.
4. ALUMINUM CONDUCTORS, ROMEX OR BX ARE NOT PERMITTED.
5. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCH -LOCK FOR #8 AND
SMALLER, AND T & B LOCK -TITE FOR #6 AND LARGER.
6. WIRES SHALL BE COLOR CODED IN KEEPING WITH LANDLORD'S
CONVENTION.
D. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR
SHERARDIZED STEEL, 4" X 4 ", KNOCK -OUT TYPE WITH FIXTURE STUDS AS
REQUIRED. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE
GALVANIZED STEEL, CODE GAUGE AND SIZE.
E. WIRING DEVICES:
1. DEVICES AND COVERPLATES SHALL BE SPECIFICATION GRADE WITH A
MINIMUM OF RATING OF 20 AMPS.
2. COLOR OF DEVICES AND COVERPLATES ARE TO BE AS FOLLOWS:
- RECEPTACLES WITHIN THE SALES AREA SLATWALL AREA ARE TO BE GRAY W
SILVER COVER PLATES.
- ALL OTHER RECEPTACLES & COVER PLATES WITHIN GYP. BD. AREAS ARE TO
BE WHITE.
HUBBELL EQUALS BY LEVITON OR COOPER WIRING DEVICES /EAGLE ELECTRIC.
DUPLEX RECEPTACLE: HUBBELL #5262
QUADRAPLEX RECEPTACLE: (2) HUBBELL #5262 UNDER ONE
(TWO GANG TYPE) COVERPLATE
ISOLATED GROUND RECEPTACLE: HUBBELL #IG -5262
QUADRAPLEX ISOLATED RECEPTACLE: (2) HUBBELL #IG-
(TWO GANG TYPE) 5262 UNDER ONE
COVERPLATE
WEATHERPROOF RECEPTACLE: HUBBELL #GF- 5262 -I
WITH "WP26" ALUMINUM
COVERPLATE
SPST SWITCH: HUBBELL #HBL -1221
THREE WAY SWITCH: HUBBELL #HBL -1223
F. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE
SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD
MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH
APPROVED GROUNDING CONNECTIONS. ELECTRICAL SYSTEM AND
EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND
N.E.C. CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR
FRAMES, UGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART
OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH
MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CODES.
MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION
250 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO
PROTECT GROUND WIRE FROM DAMAGE TO A HEIGHT OF 6 FEET ABOVE
FLOOR. MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM
TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL
GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL THREE WIRE
RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE
TRANSFORMER CONNECTED TO BUILDING STEEL GROUND CONDUCTOR
SHALL BE SUPPLIED IN ALL NON- METALLIC CONDUIT. A SEPARATE
ISOLATED, INSULATED GROUND SYSTEM SHALL BE INSTALLED FOR
ELECTRONIC CASH REGISTERS.
G. ALL PANELBOARDS SHALL BE STANDARD DEAD -FRONT CONSTRUCTION
WITH SIZE AND NUMBER OF SINGLE AND MULTI -POLE BOLT -ON BRANCH
BREAKERS AS INDICATED ON THE PANEL SCHEDULE, AND WITH MAIN
BREAKER AND MAIN LUGS AS INDICATED ON THE DRAWINGS. PANEL
BUSSING SHALL BE COPPER. PANELBOARDS SHALL BE COMPLETE WITH
TRIM, DOOR, CONCEALED HINGES, FLUSH LOCK, DIRECTORY FRAME AND
NEATLY TYPED COMPLETED DIRECTORY CARDS. ALL PANELBOARDS
SHALL HAVE DISTRIBUTED BUSSING AND SEQUENCE NUMBERING WITH
NO TWO CONSECUTIVE CIRCUIT NUMBERS TIED TO THE SAME BUS OR
PHASE. AU_ PANELS AND BREAKERS ARE PRE - PURCHASED AND SHALL BE
GENERAL ELECTRIC AS PART GYMBOREE'S NATIONAL ACCOUNT RELATIONSHIP
AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL
CONTRACTOR. ALL CIRCUIT BREAKERS USED FOR CONTROL OF UGHTING
CIRCUITS SHALL BE "SWD" RATED.
H. DRY TYPE STEP -DOWN TRANSFORMER SHALL HAVE NEMA CLASS F
INSULATION ON UNITS BELOW 30 KVA AND NEMA CLASS H INSULATION
ON UNITS 30 KVA AND ABOVE. TRANSFORMER TO BE GENERAL PURPOSE
VENTILATED TYPE WITH ALUMINUM WINDINGS. TRANSFORMER IS PRE -
PURCHASED AND SHALL BE GENERAL ELECTRIC AS PART GYMBOREE'S
NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR
INSTALLATION BY THE ELECTRICAL CONTRACTOR.
I. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT
SWITCHES SHALL BE HEAVY DUTY TYPE, 600 VOLT RATED,
QUICK -MAKE /QUICK - BREAK, WEATHERPROOF (WHERE APPLICABLE),
FUSED /NON -FUSED AS SHOWN ON THE DRAWINGS. SWITCHES USED FOR
SERVICE ENTRANCE SHALL BE "SE" RATED. STARTERS SHALL BE
MINIMUM NEMA SIZE 1. DISCONNECT SWITCHES AND COMBINATION
STARTER DISCONNECT SWITCHES ARE PRE - PURCHASED AND SHALL BE
GENERAL ELECTRIC AS PART GYMBOREE'S NATIONAL ACCOUNT RELATIONSHIP
AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL
CONTRACTOR.
J. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRIC SERVICE AND
MAKE CONNECTIONS TO THE HVAC EQUIPMENT, SIGNS AND GRILLE
MOTORS (IF APPLICABLE) AS SHOWN ON THE DRAWINGS.
K. THE ISOLATED CIRCUIT OUTLETS AT CASH WRAP AREAS SHALL BE
CLEARLY AND COMPLETELY MARKED FOR UNMISTAKABLE
IDENTIFICATION BY THE OWNER'S EMPLOYEES.
L TEMPORARY WIRING SHALL BE REMOVED WHEN WORK IS COMPLETED.
M. NO CONDUIT SHALL BE RUN THROUGH HVAC DUCTS.
N. FINALLY
1 IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETED IN
EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY
MENTIONED OR SHOWN ON THE DRAWINGS BUT NECESSARY TO FULLY
COMPLETE THE WORK SHALL THE LOCATION OF
Q LETE E 0 5 LL BE FURNISHED. TH
RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING ARE
APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE
ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT
ADDITIONAL COST.
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
IviAY - 4; 2000
City Of Tukwila
BUILDING DIVISION
ELECTRICAL RESPONSIBILITY SCHEDULE
ITEM
FURNISHED BY
INSTALLED BY
RE -USE
EXISTING
N/A
REMARKS
GYMBOREE
LANDLORD
CONTR.
LANDLORD
COMM
MAIN MR CURRENT DEVICE N
LANDLORD'S EiEC1RIC ROOM
•
• •
• •
AT 1ENANT
G.C. MANSE
METER N LANDLORD'S ELECTRIC ROOM
•
•
•
AT TENANT
C.C. DCPENSE
cirs N LANDLORD'S ELECTRIC ROOM
•
SERVICE ENTRANCE CONDUIT(S)
TO LEASE SPACE
•
•
AT TENANT
C.C. EXPENSE
SERVICE ENTRANCE FEEDER(S)
TO LEASE SPACE
•
•
OTC. SSE
277/480 VOLT PANEL (S)
•
•
MEP DN. LINE 7RANSFORMERS de
MOUNTING ACCESSORIES (AS REQUIRED)
•
•
120/208 VOLT PANEL.
•
•
HVAC DISCONNECT SWITCH
•
•
MANUAL MOTOR STARTER(S)
•
METER IN LEASE SPACE
•
C/F'S N LEASE SPACE
•
c/rs CABINET N LEASE SPACE
•
UGH1ING FIXTURES AND LAMPS
•
•
TOILET EXHAUST FAN(S)
•
•
INSTALLED BY
M.C.. MIRED
BY EC.
RECEPTACLES N SALES AREA
•
_
•
RECEPTACLES N STOCKROOM AREA
•
•
POWER WRING 70 HVAC EQUNMENT
O
•
UGH HNG CONTACTORS
•
•
POWER WRING TO 'CASiWiAP"
•
•
POWER WRING AND CONDUIT
FOR SENSORMATIC EQUIPMENT
•
FLOOR BOXES AND COVERS
•
DELIVERY BUZZER SYSTEM
•
•
?LOW
CITY 601
TELEPHONE CABLE
CONDUIT MATH PtE.LWRE
•
•
APR 0
emr-Inin RAT
DATA CABLE CONDUITS
WTH PULLWRE
•
•
TELEPHONE CABLNG AND JACKS
•
INSTALLED BY
GYMBOREE
SMOKE DEFECTOR N RETURN OR
SUPPLY AIR DUCT
•
ARE ALARM SYSTEM
•
MUSIC SYSTEM/SPEAKERS /CABNEI'
•
N BY
GYMBOREE
MUSIC SYSTEM WIRING/CONDUIT
•
•
VIRE BY
GGnl-
CONDUIT BY G.C.
R.T.U. SERVICE RECEPTACLE
_
•
•
TIME CLOCK
•
•
2-WRE LIGHTING CONTROL RELAY
•
•
AS- BUILT CRAVINGS
•
•
VED
UKVVILA
1 2008
ENTER
ELECTRICAL SPECIFICATIONS
GYMBOREE CORPORATION
500 HOWARD STREET
SAN FRANCISCO, CALIFORNIA 94105
FREDERICK J. GOGLIA
ARCHITECT, NCARB, ISP
195o CRAIG ROAD, SuTE 300 ST. LOUIS, MO 63146
PH. (314) 415 -2400 FAX (314) 415 -2300 www.arcv.com
w
m CO
� M
W
O
PROJECT INFORMATION:
a
03
N
100% CHECKSET
CO
N
LANDLORD COMMENTS
5W
g
• 49, y
FREDERICK J. GOGLIA
c 1 Ai•E OF WASHINGTON
a
Ga %�i6 T L"C
ELECTRICAL
SPECIFICATIONS
SHEET NUMBER:
E5.0