Loading...
HomeMy WebLinkAboutPermit EL08-0165 - WESTFIELD SOUTHCENTER MALL - PUMPKIN PATCHPUMPKIN PATCH 1026 SC MALL 07 -10.08 ELO8-165 Cit*f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tulnvila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1026 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -165 Issue Date: 04/09/2008 Permit Expires On: 10/06/2008 Tenant: Name: PUMPKIN PATCH Address: 1026 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: TIM SCHENK Phone: 800 541 -0821 Address: 1120 E 80 ST, STE 211 , BLOOMINGTON MN Contractor: Name: RIVIERA ELECTRIC LLC Address: 7312 NE PAR LN , VANCOUVER WA Contractor License No: RIVIEEL942D8 Phone: 503 - 740 -2291 Expiration Date: 03/28/2010 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TI Value of Electrical: $24,000.00 Fees Collected: $594.50 Type of Fire Protection: SPRINIU,ERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and exed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied h, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t1 pe rmance o ork. am authorized to sign and obtain this electrical permit. /J Signature: Date: % /F7(2J2 Print Name: V ► 11— 0 (3 E-C ime-7 Date: li . Y V L 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -165 Printed: 04 -09 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 1026 SOUTHCENTER MALL TUKW Suite No: Tenant: PUMPKIN PATCH Permit Number: ELO8 -165 Status: ISSUED Applied Date: 02/19/2008 Issue Date: 04/09/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: / t t1 Date: - /7 0 doc: Cond -Elec EL08 -165 Printed: 04 -09 -2008 CITY OF TUKWILik Community DevelopmarDepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical PereNo. EL,(71 Project No. rot - 0 Flo (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: -S King Co Assessor's Tax No.: b3G,y20 - 0010 Tenant Name: R.a.nprAyN Property Owners Name: \ W∎eka C't bCta:k∎ VI Mailing Address: 11C90 1/41`1% \sr ce crick . \elcx Los Ac e \es, GA ct40Z5 City Suite Number: 1 Z I S Floor: 1 New Tenant: ® Yes ❑ .. No State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Tim ScywyNt. Day Telephone: KOO ) S41 • OS? L1 Mailing Address: 1 I •PO Ea 4Owi - 'Q 9 t - Sv.kke- Z 11 i g \OCXVN %rig At n 1 M 1•1 2(2) City a State Zip Fax Number: °ISZl 4 - VI 09 E -Mail Address: -}A * v S e \C` (2-16evneS . C ELECTRICAL CONTRACTOR INFORMATION Company Name: -C; Qt). Mailing Address: State Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: Zip Valuation of Project (contractor's bid price): $ Z41 060 Scope of Work (please provide detailed information): Nev1_C e kO-c4e S, StA kc. eS, 1kg1nh CraShvx0p , c L... ∎ t- Will service be altered? ❑ Yes 1if No Adding more than 50 amps? ❑ Yes in No Type of Use: MerCAr 'k 11 e_ Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: it Puget Sound Energy ❑ Seattle City Light H:'\Applicalions \Fortes- Applications On Line4 -2007 - Iilecvical Permit Applicannn. doc Page 1 of 2 d RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings 5140.00 (including an attachcd garage) ❑ Garages, pools, spas and outbuildings $75.00 ea $55.00 ea Low voltage systems (alarm, furnace thermostat) RESIDENTIAL REMODEL AND SERVICE CHANCES ❑ Service change or alteration $75.00 (no added /altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits 510.00 ea ❑ Circuits added /altered without service change S50.00 (up to 5 circuits) ❑ Circuits added /altered without service change $50.00 (6 or more circuits) $7.00 ca ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMII.,Y AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) S58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service 580.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 1 SO days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Day Telephone: Mailing Address: 1 $ .21) t &Iv trt0 C1v City Date: t-vf. (3i Zoos ( Too Td- l Og zi State Zip Date Application Accepted: Date Application Expires: Staff Initials: n AApplicatinns \Forms- Applications On Lme,4 -2007 - Elecnical Permit Application.doc hh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http. / /www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -01091 Initials: JEM Payment Date: 04/09/2008 User ID: 1165 Payee: BANK OF AMERICA Total Payment: 565.60 SET ID: 0409 SET TRANSACTIONS: Set Member Amount 5 475.60 EL08 -377 90.00 TOTAL: 565.60 SET NAME: PUMPKIN PATCH TRANSACTION LIST: Type Method Description Amount Payment Check 10735890 565.60 TOTAL: 565.60 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 565.60 TOTAL: 565.60 Doc: RECSETS -06 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -00472 Initials: JEM Payment Date: 02/19/2008 User ID: 1165 Total Payment: 1,408.35 Payee: ELDER -JONES SET ID: 5000000966 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -095 1,129.70 LEwO.Se"165) 118.90 M08 -048 130.75 PGO8 -052 29.00 TOTAL: 1,408.35 TRANSACTION LIST: Type Method Description Amount Payment Check 50782 1,408.35 TOTAL: 1,408.35 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 118.90 000/345.830 1,289.45 TOTAL: 1,408.35 C779 02/19 9710 TOTAL 1400.35 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: fi ! �1„ f'4. Type of Inspection: Zioo Address: ` Og( ilfrtit Date Called: Special Instructions: Date Wanted: 7 I a.m. p.m. Requester: Phone No: IX Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: r i Inspector1 �1 Date: I Q1I4o El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .01179•415arsalfflalstx48•,..— At_ 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 643- tuc Project: [J'jPKJ pt Type of Inspection: Address: Date Called: Special Instructions: Date Wanted: ? /Io P.m. Requester: Phone No: JApproved per applicable codes. EJ Corrections required prior to approval. COMMENTS: 6/situ ii--414\ Fey DeflarnENtr APFLoJat_- Pt-0+1r D g -colS bleu Inspector: 17 6(4", Date: 07 ft 4 Oz. ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: osnld. ad __ _ ..r..: ° .s - - - ,psi{ � �1 '. -�v *1: wca. -J•'. ..y «>L: �e....or efw.` w- •yS.a_ I INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 61.4%-1475- Project: Type of Inspection: 7003 Address: qu,,144 Date Called: Special Instructions: Date Wanted: 6114., a.m: Requester: Phone No: Approved per applicable codes. ID Corrections required prior to approval. COMMENTS: Pa 04. - 1\10-tt - 'cat- Inspector: 6(4/46-ik Date: ail r I O1 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 114-/‘,H PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 �0 Pr ect: ri/P /L (m if Type of Inspection: "70 0J Address: ��jj Date Called: Special Instructions: Date Wanted: �„ / ,I/ a.m. p.m. Requester: Phone No: proved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: /0/'% - 14 //fi AZ/1 /R4iff Inspecto„f1/2/iL aa7-,6/7,64/6H Dat -4 # 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 9 81 88 INSPECTION RECORD Retain a copy with permit PERMIT NO. 4R. (206)431 -3670 Pr�ye,ct: if SAW /N fi r G// Type of Inspection: �C / Address- ,..- i0,2 6 c /e��/491. Called: Special Instructions: Date Wanted: 1//./- Requester: Phone No: proved per applicable codes. Corrections required prior to approval. OMMENTS: f Inspectors:' GC �' �l 4� /� /' �cc (!,! C r/ Date: &///,..k y $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 11.0E-x r r Po /� Type of Inspection: 7 Address: /( SairfX .Vreit , LL Date Called: e: Instructions: Date Wanted: OSpecial . p.m �-/ Requester: Phone No: ❑ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ,i6.1". .f.-,AV f� (9/4-- cif- /4' _ M ix nspecto, / CertitAll We 11 Date: /fr El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: March 12, 2008 • Cizy of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Tim Schenk 1120 East 80th Street, Suite 211 Bloomington, MN 55420 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL08 -165 Pumpkin Patch— 1026 Southcenter Mall Dear Mr. Schenk, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, Brenda Holt Permit Coordinator encl xc: File No. EL08 -165 P:\Permit Center \Correction Letters\2008\EL08 -165 Correction Ltr #1.DOC jest 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 , Building Division Review Memo Date: March 11, 2008 Project Name: Pumpkin Patch Permit #: EL08 -165 Plan Reviewer: Bill Buterbaugh 1. Overcurrent protection on plans does not meet code. Provide overcurrent protection for the transformer per NEC Table 450..3(B) � PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: E1_08 -165 DATE: 03 -20 -08 PROJECT NAME: PUMPKIN PATCH SITE ADDRESS: 1026 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Buil ing i ision 4 Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATIO» OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 03-27-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTI G: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -24-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 OAERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -165 DATE: 02 -19 -08 PROJECT NAME: PUMPKIN PATCH SITE ADDRESS: 1026 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: , ,1 3 f 1'D� Buil mg Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [V1 1 Comments: Incomplete DUE DATE: 02-26 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required n No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 03-25-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: 3.12 .op Bldg' Fire ❑ Ping ❑ PW ❑ Staff Initial Documents/routing slip.doc 2 -28 -02 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 3.19 .0 u Plan Check/Permit Number: ELO8-165 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: PUMPKIN PATCH Project Address: 1026 Southcenter Mall Contact Person: Tim Schenk Phone Number: I •`340.9 .0 $Z I Summary of Revision: fZtahS •f (hGC �3 Iv PoRtess ComM ,ICS Frukt -. (Stu-- NI reezawcf ^rpVFiEre:: dr :0 MAR, :).0 1 7P. R Sheet Number(s): E 3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 11 Entered in Permits Plus on 7�Z-6—()5 \applications\forms - applications on line \revision submittal Crcated: 8 -13 -2004 Revised: Look Up a Contractor, Electen or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License RIVIEEL942D8 Licensee Name RIVIERA ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602597971 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 7312 NE PAR LN Address 2 City VANCOUVER County CLARK State WA Zip 98662 Phone 5037402291 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/28/2006 Expiration Date 3/28/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License BECK *M *9440L Electrical Administrator Information License BECK *M *944OL Name BECK, MIRCHA Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BECK, MIRCHA PARTNER/MEMBER 03/28/2006 Bond Information Bond Bond I Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= RIVIEEL942D8 04/09/2008 TC 2 PROVIDE FLUSH MOUNTED SHO WINDOW RECEPTACLE IN;CEILIN -ABOVE PER NEC REQUIREFMENTSj ' -' TYPICAL FOR (2). 1 I i _____11 �L.__�_J I{1 . _.! I CLG ABV Z.: 1 '12" CONDUIT w/PULLSTRING TO ALARMIPANEL. FIELD VERIFY LQ�CATIONS • LIGHTING CONTRQL CABINET "LCC" PROVIDE WITH 2HR MAX OVERRIDE & ASTRO TIMECLOCK AND ALL REQUIRED PROGRAMMING AND TESTING PER ENERGY CODE REQ'MTS. (PCI # LITEKEEPER -16), OR EQUAL r- r I iiW l L —_O 120V CONTROLS PANEL "LV" 120/208V -30-4W TRANSFORMER "TA" "LV.-8 -I } l __ _... _ � —.. 4 Imm_i_ L PROVIDE - DELIVERY BUZZER MOUNTED ABOVE CEILING. CONNECT TO TRANSFORMER MOUNTED IN STOCKROOM. SEE ARCHITECTURAL DRAWINGS FOR -EX CT LOCATION AND TYPE. SECURITY PANEL COORDINATE WITH PUMPKIN PATCH PROJECT MANAGER FOR EXACT LOCATION PRIOR TO ROUGH -IN. "LV"- 26,28,30 "LV "- 20,22,24 LOCATE AND INTERCEPT EXISTING TELEPHONE CONDUIT STUBBED FROM MAIN TELEPHONE BOARD BY LANDLORD AND EXTEND TO NEW TENTANLTELEHQNE.B.QARD'�'TTB." FIELD VERIFY EXACT ENGTH PRIOR TO BIDDING. 6I 26 IG L1. +18' 26 10 28 1G 18 "LV" -16,18 16 - — - TF7'9 TB" APPROVED P' 1P,D Cr.'77,;T :Orriltn r- - :- 'c MODIFIED CR ALTERS) wimo JI AUTHORIZATION FROM THE BUILDING , AL' WORK SHALL BE DONE IN ACCORDANCE •N. r' THE APPROVED PLANS AND is 2.:' ;T TO F;: =' D'!i PrC11OH3. CAT5E 11TP CABLE COUNTER FOR INQUIRIES PLEASE CONTACT: colinsppumpkinpatch.co.nz +649 272 0765 +6421 607 770 LJ LJ LJ LJ LJ EFT DATA1 PHONE DATA2 EFT POS1 POS2 ALL COUNTER OUTLETS ARE FACEPLATES WITH DUAL RJ45 CAT5E SOCKETS. DATA1 & DATA2 ON COUNTER TO NORMAL TCP /IP STANDARDS EFTPOS1 & EFTPOS2 ON COUNTER CABLE TO CONNECTING DEVICE STANDARD 8 PORT ADSL ROUTER SWITCH (P/P CABLE (P/P SUPPUED) (P/P SUPPUED) SUPPUED) CAT5E PATCH CABLE DATA1 PHONE ADSL DATA2 t] � El STOCKROOM CONTROLLER SUPPLIED) FAX CAT5E UTP CABLE AU STOCKROOM OUTLETS ARE FACEPLATES WITH DUAL RJ45 CAT5E SOCKETS DATA1 & DATA2 IN STOCKROOM TO NORMAL TCP /IP STANDARDS PHONE/FAX/ADSL IN STOCKROOM CABLE TO CONNECTING DEVICE MAIN STOCKROOM STANDARD E1 PHONE LINE FAX AND ADSL OR BROADBAND EFTPOS /ALARM MONITORING EFTPOS ALARM CONTROL UNIT (SECURITY COMPANY SUPPUED) TYPICAL WIRING DIAGRAM NO SCALE 1"C. TO MGR DESK (DATA) 1"C. TO "TTB" (TELE) "LV "-10,12 #10 "LV" -38/40 L 1 20V CONTROLS "LV" -2,4,6 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. POWER & SIGNAL PLAN SCALE: 1/4" =11-0" 1. GENERAL NOTES: SECURITY ALARM AND TELEPHONE SYSTEMS SHALL BE INSTALLED BY THE TENANT AFTER FIXTURE INSTALLATION. CONDUIT (WHERE REQUIRED BY LOCAL CODE), BOXES AND PULLWIRES TO BE PROVIDE BY THE ELECTRICAL CONTRACTOR. COORDINATE WITH SECURITY AND TELEPHONE SYSTEMS INSTALLER AT JOBSITE. 2. REFER TO MECHANICAL DRAWINGS FOR EXACT HVAC EQUIPMENT LOCATIONS AND SPECIFICATIONS. VERIFY EQUIPMENT WIRE SIZE, CONDUIT SIZES, CIRCUIT BREAKER AND DISCONNECT SIZES WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH -IN OF ELECTRICAL. 3. ALL CONNECTIONS TO HVAC EQUIPMENT SHALL MADE WITH COPPER COND- DUCTORS ONLY. SIZE CONDUCTORS PER UNIT NAMEPLATE SPECIFICATIONS. VERIFY PRIOR TO INSTALLATION OF CONDUCTORS. 4. ALL DISCONNECT SWITCHES SHALL BE FUSIBLE, SIZE AS REQUIRED. ALL HVAC UNITS SHALL BE FUSED PER EQUIPMENT NAMEPLATE SPECIFICATIONS. ELECTRICAL CONTRACTOR SHALL VERIFY DISCONNECT AND FUSE SIZING WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING MATERIALS. 5. ALL FUSES FOR THIS PROJECT SHALL BE BUSSMAN CLASS RK5 DUAL ELEMENT CURRENT LIMITING WITH AMPERAGES AS INDICATED OR REQUIRED. 6. REFER TO MECHANICAL DRAWINGS FOR CONTROL WIRING. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT FOR CONTROL WIRING AS REQUIRED. COORDINATE WITH MECHANICAL CONTRACTOR AT JOBSITE. 7. FIRE SEAL ALL FIRE WALL PENETRATIONS FOR CONDUITS WITH AN APPROVED FIRE SEALANT AFTER CONDUIT INSTALLATION. FIRE SEAL SHALL PROVIDE EQUAL FIRE RATING AS WALL. 8. 20A, 120V RECEPTACLE AND LIGHTING CIRCUIT CONDUCTORS OVER 75 FT. LONG SHALL BE #10 AWG CONDUCTORS IN LIEU OF #12 AWG. 9. MOUNT ALL FIXTURE JUNCTION BOXES ABOVE ACCESSIBLE CEILING WHEN APPLICABLE. L REVIEWED FOR CODE FP OP COMPLIANCE N A NEC E APR - 7 2008 "LV" -36 PROVIDE 1W EXTENSION RINC3 E R OUTLETS @ MANAGER'S DESK TO ALLOW FOR CABINETRY. +40" A.F.F.- PROVIDE PUSH - BUTTON, TRANSFORMER, WIRING, BU77FRS & CONNECTIONS FOR DELIVERY CALL SYSTEM. ')LV " -14 C City -Of Tukwila BUILDING D ION • SEPARATE PERMIT REQUIRED FOR: Et:Mechanical ❑ Electrical lumbing Gas Piping City of Tukwila BUILDING DIVISION --1 NOTE: ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL ALL INTERCONNECTING CONTROL WIRING, CONTACTORS AND CONDUIT FOR HVAC UNITS AS REQUIRED. PROVIDE SLAVE RELAY AFTER TIMECLOCK w/ NORMALLY OPEN & NORMALLY CLOSED CONTACTS FOR HVAC CONTROL. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION. NOTE TO CONTRACTOR THE CONTRACTOR SHALL THOROUGHLY REVIEW THESE ELECTRICAL CONSTRUCTION DOCUMENTS PRIOR TO PREPARING A BID FOR THE ELECTRICAL WORK SHOWN. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OP EXISTING ELECTRICAL SERVICES AND CONNECTION REQUIREMENTS. THE CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY CONFLICTS OR DISCREPANCIES FOUND PRIOR TO BID. BY SUBMITTING A BID FOR THE ELECTRICAL WORK THE CONTRACTOR IS AFFIRMING THAT THE REQUIRED FIELD VERIFICATION OF EXISTING CONDITIONS HAS BEEN COMPLETED AND ASSUMES FULL RESPONSIBILITY FOR CONFLICTS FOUND AFTER THE AWARD OF THE ELECTRICAL CONTRACT. NO ADDITIONAL COMPENSATION WILL BE CONSIDERED FOR CONFLICTS AND /OR DISCREPANCIES FOUND TO EXIST AFTER THE AWARD OF THE ELECTRICAL CONTRACT. Permit No. PIar review approval Is object to enzirs and ohs. Approval of construction doh does not authorize the violation of any act code or ordnance. Receipt of approved Field Copy and conditions is : BY Date :, City of Tukwila BUILDING DIVISION Public Works, Building Division PERMIT NUMBER RECEIVED CITY OF TUKWILA FEB 19 2008 PEKMIT CENTER *LN-- INT ELECTRICAL ENGINEERING, INC 1786 Augusta Ls Ste B. Yuba City, CA 95993 Pk 530.790.0620 Fax: 530.67t9792 ISMEEMMMI DATE: 1 -28 -08 JOB NO: 07142 DRAWN: JP CHECKED: JL 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 z U z SOUTHCENTER J W L.� N M W M SOUTHCENTER MALL TUKWILA, WA EXPIRES 06- 23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 INEEMMM POWER AND SIGNAL PLAN SHEET NUMBER E -1 PROVIDE DISCONNECT, J -BOX AND CONNECTION TO TENANT SIGNAGE. COORDINATE EXACT LOCATION AND REQUIREMENTS WITH SIGNAGE CONTRACTOR IN FIELD PRIOR TO ROUGH -IN OF ELECTRICAL. 15 r — 13 9.9. .91299,9 91:mcwas.19:999.9 sw lI iV O�7c 17d,e "LV " -1,3 VIA "LCC" sw 17 ' -- 17 [ EKfffVL_ ®1 3b 17d,e PORTAL SHOWN HERE FOR CLARITY PORTAL LIGHTING AND SIGNAGE POWER TO BE ROUTED FROM BOTTOM. NO CONNECTIONS AVAILABLE FROM ABOVE. I 1 L PROVIDE UN- SWITCHED CIRCUIT FOR EMERGENCY AND NIGHTLIGHT FIXTURES AS REQUIRED, TYPICAL. 17d.e PROVIDE OUTLET MOUNTED ABOVE ACCESSIBLE CEILING. FIELD VERIFY EXACT LOCATION. J JIM r 17d,e "LV" -13,15 VIA "LCC" PROVIDE FLUSH MOUNTED J -BOX WITH FLEX CONNECTION T DISPLAY CABINET MOUNTED LIGHTING. CONDUIT TO BE CONCEALED IN WALL, TYPICAL NOTE: E.C. TO FIELD ADJUST OR STAGGER COVE STRIP FIXTURES AND CABINET FIXTURES AS REQUIRED. FIELD VERIFY. NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge LIGHTING PLAN SCALE- -u4" = 1' -0" FIXTURE SCHEDULE TAG DESCRIPTION MANUFACTURER VOLTS LAMPS VA MOUNTING REMARKS CAM) ROUND SEMI - RECESSED METAL HALIDE ADJUSTABLE WALL WASHER LITON # LHMB6070A w/ LR6277 -23W 120 1 -70W MH 86 RECESSED (I;) 8" DIA RECESSED TWIN LAMP FLUOR. DOWNLIGHT WITH GLASS TRIM LITON # LFHN8242UE w/ LR852W -FR 120 (2) 42W CFL 841 84 RECESSED SAME AS TYPE "B" EXCEPT WITH BATTERY BACKUP. LITON # LFHN8232UE -EM w/ LR852W -FR 120 (2) 32W CFL 841 64 RECESSED CONNECT TO UN- SWITCHED CIRCUIT AS REQUIRED BE RECESSED LOW VOLTAGE DOWNLIGHT w /ELEC TRANS. LITON # LR1424W w/ LH99 -GU10 120 1 -16W LED 16 RECESSED O4" RECESSED LOW LEVEL AISLE STEPLIGHT DABMAR # DSL- 1043SS w/ 13WPU841 120 1 -13W PL 13 RECESSED 4 FT, SINGLE LAMP FLUORESCENT STRIPLIGHT SIMKAR # CH132 -BII -UNV w/ (1) WG140 120 1 -F32T8 -741 40 CHAIN HUNG PROVIDE SURFACE MOUNT WHERE REQUIRED. 0 4 FT, SINGLE LAMP FLUORESCENT STRIPLIGHT SIMKAR # CH132-BII-UNV 120 1 -F32T8 -741 40 COVE 0 LOW VOLTAGE PENDANT LIGHT WITH INDIVIDUAL TRANSFORMER LITON # LPR1012N -N w/ RS12 -80M 120 1 -16W LED 16 PENDANT 0 RECESSED LED EDGE -LIT EXIT SIGN w/BATT. BACK -UP ROYAL # RXL21GA 120 w /FIXTURE 5 RECESSED CONNECT TO UN- SWITCHED CIRCUIT AS REQUIRED 0 0 COMBO EXIT AND TWIN HEAD EMERGENCY LIGHT WITH BATTERY BACK -UP # NEX- 705 -LED /G 120 w /FIXTURE 5 RECESSED CONNECT TO UN- SWITCHED CIRCUIT AS REQUIRED 1 MASTER SWITCH LOCATION "a" - 50% SALES LIGHTING "b" - 50% SALES LIGHTING "c" - SALES DISPLAY LIGHTS "d" - BON LIGHTING PROVIDE 3- POSITION LOW VOLTAGE SWITCHING. PROVIDE WALL MOUNTED OCCUPANCY SENSOR (HUBBELL #IWSZPM) OR EQUIVALENT. (AUTO ON /OFF 30 MIN MAX) t4 b LV c LV d LV #14 TO "LCC" NL 17 17d TOGGLE SWITCH TO BE DOWNSTREAM OF M k ER CONTROL SWITCH "d ". EM X1 1, REVIEWED FOR CODE COMPLIANCE NFPAi0 -NEC APR - 7 2008 BUILDING �i� flf Tukwila DIVV ION 1(eC EED CITY TUKWILA FEB 19 2008 PtriMi f LENTER IMMIMMME DATE: 1 -28-08 JOB NO: 07142 DRAWN: JP CHECKED: JL 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635-5699 L J z n� 0 SOUTHCENTER J W L.� N W SOUTHCENTER MALL TUKWILA, WA EXPIRES 06 -23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 LIGHTING PLAN SHEET NUMBER IiHT E - 2 ELECTRICAL ENGINEERING. INC 1786 Augusta Ln Ste B, Yuba City, CA 95993 Ph: 530.790.0620 Fa= 530.671.9792 1 MALL ELECTRICAL ROOM J 2 TENANT SPACE N./ EPM- 4000 - EXISTING LANDLORD PANEL "1 F" 800A, 277/480V, 30-4W, 800A (FIELD VERIFY AIC) 14,801 T1215 (E) 200AF o (E) EPM -4000 INTERFACE- EXISTING LANDLORD METER CENTER - PROVIDE 200A FUSES IN LANDLORD'S SWITCH (FIELD VERIFY REQUIREMENTS) EXISTING (4) #250KCMIL, (1)#4G,AL MC CABLE. (E) 2 "C. w/ NEW 3 # 1 THWN CU & 1 # 8 CU GROUND BY ELEC. CONTRACTOR PROVIDE #4 AWG CU GND. TO NEAREST BLDG. STEEL PER NEC REQUIREMENTS. (E) 200AS 100AF EXISTING (3) #3, 1 - #8G, 1 1 /4 "C (CONDUIT STUB TO TENANT SPACE BY L.L.) ELECTRICAL CONTRACTOR TO PROVIDE NEW FUSES TO MATCH EXISTING LANDLORD EQUIPMENT. FIELD VERIFY EXACT REQUIREMENTS. ELECTRICAL CONTRACTOR TO INTERCEPT EXISTING TENANT FEEDER & CONDUIT AND EXTEND TO RELOCATED EQUIPMENT AS REQUIRED. PROVIDE NEW PRIMARY DISCONNECT AND FUSES AS SHOWN NEW 1 "C.wl3 #4THWNCU &1 # 8 CU GROUND NEW TRANSFORMER 'TA" 1 _ , 1 45 KVA DRY -TYPE, 30 TRANSFORMER, 480V DELTA - 120/208 WYE FLOOR MOUNTED. CLASS 1 EFF. (NEMA TP -1) 2 NEW 2 "C. w/4 # 1/0 THWN CU & 1 # 6 CU GROUND 0 150A 3P NEW PANEL "LV" ONE LINE DIAGRAM NO SCALE NOTE: E.C. TO FIELD VERIFY ALL ELECTRICAL EQUIPMENT AND SIZES FOR CONDUIT, WIRE, AND BREAKERS. E.C. SHALL MAKE APPROPRIATE ADJUSTMENTS SO THAT WORK COMPLIES WITH THE NEC. TC TC TC TC TC TC SW SW LO GENERAL NOTES: 1. ALL THE ELECTRICAL SERVICE SHOWN ON THE ONE LINE DIAGRAM IS THE TENANT ELECTRICAL CONTRACTOR'S RESPONSIBILITY. RESPONSIBILITY INCLUDES COORDINATION WITH THE LOCAL SERVING POWER COMPANY. 2. CIRCUIT BREAKER TYPE PANELBQARDS WITH BOLT -ON TYPE CIRCUIT BREAKERS WITH ADEQUATE INTERRUPTING CAPACITY SHALL BE INSTALLED. 3. THE GROUNDING SYSTEM WITHIN THE PREMISE SHALL BE CONTINUOUS FROM THE SYSTEM GROUND IN THE METER ROOM. THE SECONDARY OF THE TENANT TRANSFORMERS SHALL BE GROUNDED IN ACCORDANCE WITH THE N.E.C. 4. ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH LOCAL AND NATIONAL CODES. ALL POWER WIRE IN THE PREMISE SHALL BE INSTALLED IN CONDUIT. CONDUCTOR INSULATION SHALL BE THW, THHN, OR THWN. NO ROMEX WIRES ARE ALLOWED. LOW VOLTAGE CABLES MAY BE INSTALLED WITHOUT CONDUIT WHERE PERMITTED BY LOCAL CODE AND INSPECTION AGENCIES. 5. ALL ELECTRICAL MATERIALS SHALL BE NEW AND SHALL BE NATIONAL ELECTRICAL CODE STAN- DARD UNLESS BETTER GRADE IS REQUIRED BY LOCAL CODE, AND SHALL BEAR THE UNDER- WRITERS' LABORATORIES LABEL. 6. ALL TELEPHONE SERVICES SHALL BE PROVIDED BY THE TENANTS ELECTRICAL CONTRACTOR. ALL TELEPHONE CHARGES SHALL BE PAID BY THE TENANT'S ELECTRICAL CONTRACTOR DIRECTLY TO THE TELEPHONE UTILITY COMPANY FURNISHING THE SERVICE. COMPLETE CONDUIT SYSTEM, IF REQUIRED, SHALL BE PROVIDED BY TENANTS ELECTRICAL CONTRACTOR FOR UTILITY COMPANY WITH PULL WIRES INSTALLED IN ALL CONDUIT. 7. WHEN SPACE ABOVE CEILING IS INDICATED TO BE A RETURN AIR PLENUM. PLENUM NONCOMBUSTIBLE. CONSTRUCTION MATERIALS TO BE USED ABOVE CEILING, INCLUDING EXISTING AND NEW WIRING EXCEPT INSULATION OF 25 FLAME SPREAD AND 50 SMOKE DEVELOPMENT FINISH RATING. LOW VOLTAGE OR LIMITED POWER WIRING MAY BE LABELED PLENUM RATED TYPE ALL PER OMC M -3032. LOAD CALCULATIONS: NEW PANEL "LV" LIGHTING (CONNECTED) SIGNAGE = SHOW WINDOW - 20' @ 200W/LF RECEPTACLES - 28 @ 180W EACH INST WATER HEATER "WI-1"-1 MICROWAVE REFRIGERATOR SUB -TOTAL 25% CONTINUOUS LOAD 25% LARGEST MOTOR TOTAL FOR 120/208V -30-4W SYSTEM 31,553W- (208VxV3)= 87.6AMPS THEREFORE A 150 AMP FEEDER IS ADEQUATE. FOR 277/480V -30-4W SYSTEM 31,553 W - (480V xV3) = 38.0 AMPS THEREFORE A 100 AMP FEEDER IS ADEQUATE. 10,170 W 1,200 W 4,000 W 5,040 W 3,000 W 1,500 W 700 W 28,610 W 2,843 W 100 W 31,553 W SW LO LO LO LO LO SYMBOL LEGEND • • 2 3 M acc V 0 La LEI LD 0 EMI FLUORESCENT LIGHT FIXTURE - SURFACE MOUNTED INCANDESCENT LIGHT FIXTURE - PENDANT MOUNTED FLUORESCENT STRIP LIGHT - SURFACE MOUNTED UNO INCANDESCENT / FLUORESCENT / HID LIGHT FIXTURE - RECESSED INCANDESCENT LIGHT FIXTURE - SURFACE MOUNTED INCANDESCENT LIGHT FIXTURE - WALL MOUNTED EXIT LIGHT - CEILING MOUNTED WITH EMERGENCY LIGHTS EXIT LIGHT - WALL MOUNTED WITH ARROWS AS SHOWN EMERGENCY LIGHTING FIXTURE - SURFACE MOUNTED SINGLE POLE TOGGLE SWITCH, @ +46" UNO TWO POLE TOGGLE SWITCH, @ +46" UNO THREE -WAY TOGGLE SWITCH, @ +46" UNO MOTOR RATED SINGLE POLE SWITCH, @ UNIT UNO MASTER LIGHTING CONTROL STATION OCCUPANCY SENSOR @ +46" UNO (LEVITON # 00515) FIXTURE TAG: LETTER INDICATES TYPE JUNCTION BOX, SIZE & TYPE AS INDICATED OR AS REQUIRED 15 OR 20 AMP 125V 3W DUPLEX RECEPTACLE, @ +16" UNO 15 OR 20 AMP 125V 3W DOUBLE DUPLEX RECEPTACLE, @ +16" UNO CEILING MOUNTED DUPLEX RECEPTACLE NON -FUSED DISCONNECT SWITCH CIRCUIT BREAKER DISCONNECT SWITCH FUSED DISCONNECT SWITCH, SIZE PER UNIT LABEL MOTOR, N.I.E.S. CONNECT AS REQUIRED, NUMBER INDICATES HP CONTROL EQUIPMENT, N.I.E.S. CONNECT AS REQUIRED PANELBOARD - SEE SCHEDULE MAIN SWITCHBOARD OR MOTOR CONTROL CENTER, SEE ONE LINE DIAGRAM DISTRIBUTION TRANSFORMER, MOUNTING AS NOTED TERMINAL CABINET, SIZE & TYPE AS NOTED CEILING EXHAUST FAN DATA OUTLET, 4" SQ. BOX w/ SINGLE DEVICE RING & PLATE @ +16" UNO TELEPHONE OUTLET, 4" SQ. BOX w/ SINGLE DEVICE RING & PLATE @ +16" UNO DUPLEX RECEPTACLE FLUSH w/ FINISHED FLOOR CEILING MOUNTED DATA OUTLET TELEPHONE TERMINAL BOARD: 4' x 8' x r PLYWOOD OR AS NOTED w/ DOUBLE DUPLEX RECEPTACLE & 1 #6 GND -LV-- LOW VOLTAGE WIRING IN CONDUIT [" CONDUIT RUN CONCEALED BELOW FLOOR OR FINISHED GRADE, U.N.O. r CONDUIT CONCEALED IN CEILING OR WALL, U.N.O. HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - OVERHEAD HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - UNDERGROUND CONDUIT RISER - UP CONDUIT RISER - DOWN BRANCH CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 #12 WIRE CIRCUIT ADDITIONAL NO. OF #12:-1-11--, 3 #12;-- 1-!-f, 2 #12 & 1 #12 GND, 1I I I1( , 5 #12 & 1 #12 GND, ETC. OTHER WIRE SIZES: 2 #10 & 1 #12 GND;-f# -•F, 3 #4 & 1 #8 GND, ETC. #10 #12 #4 #8 MT EL NL (E) (N) (R) C. WP FACP 0 PFB EMPTY CONDUIT WITH PULLSTRING EMERGENCY LIGHT NIGHT LIGHT EXISTING NEW RELOCATE CONDUIT WEATHERPROOF FIRE ALARM CONTROL PANEL SMOKE DETECTOR, MOUNTING AS NOTED FIRE ALARM MANUAL PULLSTATION DUCT SMOKE DETECTOR FIRE ALARM STROBE UNIT, WALL MOUNTED FIRE ALARM COMBINATION HORN /STROBE UNIT, WALL MOUNTED REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 7 2088 �tY -0f Tukwii� B ILDIN DIVISION PROVIDE FOR FUTURE BREAKER FLAG NOTE SHOWN ON SAME SHEET SECTION DESIGNATION: TOP LETTER INDICATES SECTION, BOTTOM LETTER/NUMBER INDICATES SHEET DETAIL DESIGNATION: TOP NUMBER INDICATES DETAIL, BOTTOM LETTER/NUMBER INDICATES SHEET MECHANICAL & PLUMBING EQUIPMENT DESIGNATION NOTE: SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. Public Works, Buil PERMIT NU 4,1 %1g Division BER 08- CORRECT LTR# ?ifie RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER DATE: 1 -28-08 JOB NO: DRAWN: CHECKED: 07142 JP JL EINEMESIONIMMIENIM 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 IMMINIMMEMINEMINIME W D z 0 0 ELD SOUTHCENTER W SOUTHCENTER MALL t) 06 o3 V , EXPIRES 06 -23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 PLAN CHECK COMMENTS 12, MARCH. 08 ONE LINE DIAGRAM LEGEND, NOTES AND DETAILS JC-3 MENEMENEMMMEEME SHEET NUMBER OPIiT ELECTRICAL ENGINEERING. INC 1786 Augusta Ln Ste B. Yuba City, CA 95993 Pic 530.790.0620 Fax 530.671.9792 E -3 FILE coPr NEW ❑ EXISTING P A N E L "LV" LVI I AIC: 10,000 VOLTAGE: 120/208V -30-4W MAIN: 150A MAIN CKT BRKR BUS: 200 AMP MOUNTING: SURFACE LOCATION: STOCKROOM 8g z KVA LOAD LOAD DESCRIPTION CKT BRKR BUS CKT BRKR LOAD DESCRIPTION L KVA LOAD p.. x 6 0 z PH A PH B PH C TRIP POLES A B C TRIP POLES PH A PH 0 PH C 1 1.4 GEN. SALES DOWNLIGHTS 20 1 20 1 SHOW WINDOW RECS 0.4 2 „ „ 3 1.3 GEN. SALES DOWNLIGHTS 20 1 20 1 SECURITY TRANSFORMER 02 4 5 1.3 SALES DISPLAY LIGHTS 20 1 20 1 SALES CONV RECEPTACLES 0.5 6 ;, 7 1.4 SALES DISPLAY LIGHTS 20 1 20 1 SALES CONV RECEPTACLES 0.5 8 9 0.9 DISPLAY CASE LIGHTING 20 1 20 1 CASHWRAP CONV RECEPTS 0.4 10 is; 11 1.1 COVE LIGHTING 20 1 20 1 CASH REGISTERS 1.8 12 „ 13 0.7 SHOW WINDOW LIGHTING 20 1 20 1 RESTROOM GFCI RECEPT 0.2 14 ;; 15 1.2 SIGNAGE 20 1 20 1 BACK OFFICE RECEPTACLES 0.4 16 17 1.0 EMERGBACK AREA LIGHTS 20 1 20 1 BACK OFFICE RECEPTACLES 0.2 18 19 SPARE 20 1 20 1 MICROWAVE 1.5 20 in 21 20 1 20 1 FRIDGE 0/ 22 ;, 23 J , 20 1 20 1 AN RACK 0.5 24 „ 25 SPACE PFB 20 1 "TTB" RECEPTACLES 0.4 26 &&I; , 27 20 1 "TTB" RECEPTACLE 0.2 28 29 20 1 SECURITY PANEL 0.4 30 ii 31 20 1 LIGHTING CONTROL "LCC" 0.1 32 33 35 1 VAV CONTROL 0.2 34 1 35 20 1 VAV CONTROL 02 36 „ 37 20 INST WATER HEATER 1.5 38 i1 39 2 \1, 1.5 40 11 41 u � PFB SPARE 42 NOTES - LINE TOTALS 25% CONT. LOAD TOTAL KVA/PH. UNE AMPS TOTAL KVA LOAD 8.1 7.0 7.0 sw = SHOW WINDOW, PROGRAM CIRCUIT IN "LCC" PER MALL REQUIREMENTS. TC = TIME -CLOCK CONTROL PROGRAM CIRCUIT FOR AFTER HOURS SHUT -OFF PER ENERGY CODE REQUIREMENTS NL = NIGHT LIGHT, PROVIDE ADDITIONAL UN- SWITCHED, NON -LCC CONTROLLED CIRCUIT. LO = LOCK -ON, PROVIDE LOCK ON DEVICE AND UN- SWITCHED, NON --LCC CONTROLLED CIRCUIT. 0.9 0.9 0.9 9.0 7.9 7.9 75 66 66 24 8 / 68.8A SW LO LO LO LO LO SYMBOL LEGEND • • 2 3 M acc V 0 La LEI LD 0 EMI FLUORESCENT LIGHT FIXTURE - SURFACE MOUNTED INCANDESCENT LIGHT FIXTURE - PENDANT MOUNTED FLUORESCENT STRIP LIGHT - SURFACE MOUNTED UNO INCANDESCENT / FLUORESCENT / HID LIGHT FIXTURE - RECESSED INCANDESCENT LIGHT FIXTURE - SURFACE MOUNTED INCANDESCENT LIGHT FIXTURE - WALL MOUNTED EXIT LIGHT - CEILING MOUNTED WITH EMERGENCY LIGHTS EXIT LIGHT - WALL MOUNTED WITH ARROWS AS SHOWN EMERGENCY LIGHTING FIXTURE - SURFACE MOUNTED SINGLE POLE TOGGLE SWITCH, @ +46" UNO TWO POLE TOGGLE SWITCH, @ +46" UNO THREE -WAY TOGGLE SWITCH, @ +46" UNO MOTOR RATED SINGLE POLE SWITCH, @ UNIT UNO MASTER LIGHTING CONTROL STATION OCCUPANCY SENSOR @ +46" UNO (LEVITON # 00515) FIXTURE TAG: LETTER INDICATES TYPE JUNCTION BOX, SIZE & TYPE AS INDICATED OR AS REQUIRED 15 OR 20 AMP 125V 3W DUPLEX RECEPTACLE, @ +16" UNO 15 OR 20 AMP 125V 3W DOUBLE DUPLEX RECEPTACLE, @ +16" UNO CEILING MOUNTED DUPLEX RECEPTACLE NON -FUSED DISCONNECT SWITCH CIRCUIT BREAKER DISCONNECT SWITCH FUSED DISCONNECT SWITCH, SIZE PER UNIT LABEL MOTOR, N.I.E.S. CONNECT AS REQUIRED, NUMBER INDICATES HP CONTROL EQUIPMENT, N.I.E.S. CONNECT AS REQUIRED PANELBOARD - SEE SCHEDULE MAIN SWITCHBOARD OR MOTOR CONTROL CENTER, SEE ONE LINE DIAGRAM DISTRIBUTION TRANSFORMER, MOUNTING AS NOTED TERMINAL CABINET, SIZE & TYPE AS NOTED CEILING EXHAUST FAN DATA OUTLET, 4" SQ. BOX w/ SINGLE DEVICE RING & PLATE @ +16" UNO TELEPHONE OUTLET, 4" SQ. BOX w/ SINGLE DEVICE RING & PLATE @ +16" UNO DUPLEX RECEPTACLE FLUSH w/ FINISHED FLOOR CEILING MOUNTED DATA OUTLET TELEPHONE TERMINAL BOARD: 4' x 8' x r PLYWOOD OR AS NOTED w/ DOUBLE DUPLEX RECEPTACLE & 1 #6 GND -LV-- LOW VOLTAGE WIRING IN CONDUIT [" CONDUIT RUN CONCEALED BELOW FLOOR OR FINISHED GRADE, U.N.O. r CONDUIT CONCEALED IN CEILING OR WALL, U.N.O. HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - OVERHEAD HOMERUN TO RESPECTIVE PANEL OR TERMINAL CABINET - UNDERGROUND CONDUIT RISER - UP CONDUIT RISER - DOWN BRANCH CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 #12 WIRE CIRCUIT ADDITIONAL NO. OF #12:-1-11--, 3 #12;-- 1-!-f, 2 #12 & 1 #12 GND, 1I I I1( , 5 #12 & 1 #12 GND, ETC. OTHER WIRE SIZES: 2 #10 & 1 #12 GND;-f# -•F, 3 #4 & 1 #8 GND, ETC. #10 #12 #4 #8 MT EL NL (E) (N) (R) C. WP FACP 0 PFB EMPTY CONDUIT WITH PULLSTRING EMERGENCY LIGHT NIGHT LIGHT EXISTING NEW RELOCATE CONDUIT WEATHERPROOF FIRE ALARM CONTROL PANEL SMOKE DETECTOR, MOUNTING AS NOTED FIRE ALARM MANUAL PULLSTATION DUCT SMOKE DETECTOR FIRE ALARM STROBE UNIT, WALL MOUNTED FIRE ALARM COMBINATION HORN /STROBE UNIT, WALL MOUNTED REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 7 2088 �tY -0f Tukwii� B ILDIN DIVISION PROVIDE FOR FUTURE BREAKER FLAG NOTE SHOWN ON SAME SHEET SECTION DESIGNATION: TOP LETTER INDICATES SECTION, BOTTOM LETTER/NUMBER INDICATES SHEET DETAIL DESIGNATION: TOP NUMBER INDICATES DETAIL, BOTTOM LETTER/NUMBER INDICATES SHEET MECHANICAL & PLUMBING EQUIPMENT DESIGNATION NOTE: SYMBOLS INDICATED ABOVE MAY NOT NECESSARILY APPEAR AS PART OF THESE DRAWINGS IF NOT REQUIRED. Public Works, Buil PERMIT NU 4,1 %1g Division BER 08- CORRECT LTR# ?ifie RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER DATE: 1 -28-08 JOB NO: DRAWN: CHECKED: 07142 JP JL EINEMESIONIMMIENIM 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 IMMINIMMEMINEMINIME W D z 0 0 ELD SOUTHCENTER W SOUTHCENTER MALL t) 06 o3 V , EXPIRES 06 -23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 PLAN CHECK COMMENTS 12, MARCH. 08 ONE LINE DIAGRAM LEGEND, NOTES AND DETAILS JC-3 MENEMENEMMMEEME SHEET NUMBER OPIiT ELECTRICAL ENGINEERING. INC 1786 Augusta Ln Ste B. Yuba City, CA 95993 Pic 530.790.0620 Fax 530.671.9792 E -3 FILE coPr 44" El V El li9 v IN • El 0 0 PROVIDE QUADPLEX CONVENIENCE RECEPTACLE. TYPICAL OF (3). PROVIDE SINGLE -GANG J -BOX CONTAINING (2) DATA JACKS AND (1) PHONE JACK. 1 0 TYPICAL MANAGER'S DESK ELEVATION SCALE: NONE FLOOR 1 PROVIDE SINGLE -GANG J -BOX CONTAINING (2) DATA JACKS. FLEXIBLE CONDUIT AND CONDUCTORS BY E.C.. PROVIDE PULLSTRING IN ALL EMPTY CONDUITS. TYPICAL. • �_ >-C 0 ao >C up • • 11 PROVIDE ISOLATED GROUND RECEPTACLE. TYPICAL OF (2) PROVIDE QUADPLEX CONVENIENCE RECEPTACLE. TYPICAL OF (2). PROVIDE SINGLE -GANG J -BOX CONTAINING (2) DATA JACKS AND (1) PHONE JACK. PROVIDE AND CONNECT J -BOXES TO CONDUIT STUB -OUTS. PLACE J -BOXES IN TOE -KICK CABINET SPACE WHERE POSSIBLE. PROVIDE PULLSTRING IN ALL EMPTY PHONE/DATA CONDUITS. 1 —D- TYPICAL CASHWRAP ELEVATION E4 SCALE: NONE FLOOR 0 0 0 [1 0 0 n 0 a o 0 0 0 0 O O 0 gg s 0 0 0 a o 0 1 o 0 0 TYPICAL REAR COUNTER ELEVATION E4 SCALE: NONE REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 7 2008 Oty Of Tukwila B ILDING DM ION FC,041-ice RECEIVED CITY OF TUKWILA FEB 1 9 2008 'EHMI f CENTER DATE: 1-28-08 JOB NO: 07142 DRAWN: JP CHECKED: JL 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 L J N SOUTHCENTER WESTFIELD SOUTHCENTER \BALL V) TUKWILA, WA EXPIRES 06 -23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 ELECTRICAL DETAILS SHEET NUMBER IHT E - 4 ELECTRICAL ENGINEERING. INC 1786 Augusta Ln Ste B, Yuba City, CA 95993 Ph: 530.790.0620 Far 530.671.9792 lal • t gg s T 16" ,, 1 TYPICAL REAR COUNTER ELEVATION E4 SCALE: NONE REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 7 2008 Oty Of Tukwila B ILDING DM ION FC,041-ice RECEIVED CITY OF TUKWILA FEB 1 9 2008 'EHMI f CENTER DATE: 1-28-08 JOB NO: 07142 DRAWN: JP CHECKED: JL 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 L J N SOUTHCENTER WESTFIELD SOUTHCENTER \BALL V) TUKWILA, WA EXPIRES 06 -23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 ELECTRICAL DETAILS SHEET NUMBER IHT E - 4 ELECTRICAL ENGINEERING. INC 1786 Augusta Ln Ste B, Yuba City, CA 95993 Ph: 530.790.0620 Far 530.671.9792 ELECTRICAL SPECIFICATIONS SECTION 16050: GENERAL ELECTRICAL The General Conditions, Supplementary Conditions, and Division 1 apply to work under this Section PART 1 GENERAL: 1.01 DESCRIPTION A. General: Furnish all labor, materials, apparatus, tools, equipment, transportation, temporary construction and special or occasional services as required to make a complete working electrical installation, as shown on the drawings or described in these specifications. B. Work included: 1. Installation and assembly of Owner furnished lighting fixtures and lamps. 2. Grounding. 3. Connections of smoke detectors furnished and installed by Mechanical. 4. Panels and overcurrent devices. 5. Branch circuit wiring. 6. Exit signs and emergency lighting system. 7. Installation of convenience outlets. 8. Installation of telephone and data outlets and raceways. 9. Furnishing, support and installation of new transformer. 10. Rough -in wiring for display case lighting. 11. Demolition and removals. 12. Lighting controls, and time switches. 13. Connections of, and power wiring to, HVAC equipment and food service equipment. 14. Conduit for data, telephone and alarm systems. C. Related Work Specified Elsewhere: 1. Perform the following work, in accordance with appropriate sections of the specifications cited, where and as necessary to furnish a complete, working electrical installation. a. Concrete: b. Painting: c. Door hardware: d. Mechanical: e. Food Service Equipment: Division 3 Division 9 Division 11 Division 15 Division 15 D. Related Work Not included in Contract: 1. Installation of primary and secondary utility cables. 2. Installation of telephone instruments and equipment. 3. Installation of data cable or computer equipment. 1.02 CODES AND STANDARDS: A. Specific 1. The following publications or latest enacted editions throughout construction shall apply. a. National Electrical Code. b. State and Local Building and Energy Codes. c. Uniform Building Code. of the documents 2. Equipment and materials specified under this division shall conform to the following standards where applicable. a. UL Underwriters' Laboratories. b. ASTM American Society for Testing Materials, c. CBM Certified Ballast Manufacturers, d. ANSI American National Standards. Institute. e. NEMA National Electrical Manufacturers Association 1.03 DRAWINGS: A. Layout: General layout shown on the drawings shall be followed except where other work may conflict with the drawings. B. Accuracy. 1. Drawings for the work under this Section are diagrammatic. 2. Contractor shall verify lines, levels and dimensions shown on the Drawings and shall be responsible for the accuracy of the setting out of work and for its strict conformance with existing conditions at the site. 1.04 SUBSTITUTIONS: Refer to the General Conditions, Supplementary Conditions and Division 1 for substitution. 1.05 SUBMITTALS: A. General: Refer to the General Conditions, Supplementary General Conditions and Division 1 for requirements. B. Format: Furnish submittal data neatly bound in an 8 -1/2" X 11" folder or binder with a table of contents listing in order of specification section and paragraph number. C. Submittals shall consist of detailed shop drawings, specifications, catalog "cuts" and data sheets containing physical and dimensioned information, performance data, electrical characteristics, materials used in fabrication, material finish and those optional accessories which are included and those which are excluded. D. Each submittal shall be thoroughly reviewed by the Contractor. The cover letter accompanying submittal letter shall list in full the items and data submitted and shall contain a statement acknowledging that the Contractor has performed a detailed review of the submittal documents prior to submission. Failure to comply with this requirement shall constitute grounds for return of data for resubmission without review. E. Contractor agrees that Shop Drawing submittals processed by the engineer are not change orders, that the purpose of Shop Drawing submittals by the Contractor is to demonstrate to the engineer that the Contractor understands the design concept, that he demonstrates his understanding by indicating which equipment and material he intends to furnish and install and by detailing the fabrication and installation methods he intends to use. 1.06 PRODUCT DELIVERY, STORAGE AND HANDLING: Equipment and materials shall be properly stored and adequately protected and carefully handled to prevent damage before and during installation. Equipment and materials shall be handled, stored, and protected in accordance with the manufacturers's recommendations and as approved by the Owner's Representative. Electrical conduit shall be stored to provide protection from the weather and accidental damage. Plastic conduit shall be stored on even supports and in locations not subject to direct sun rays or excessive heat. Cables shall be sealed, stored and handled carefully to avoid damage to the outer covering or insulation and damage from moisture and weather. Damaged or defective items, in the opinion of the Owner's Representative, shall be replaced with new items at no cost to the Owner. 1.07 PERMITS AND FEES: Provide, procure and pay for all permits, licenses and fees required to carry on and complete the work. PART 2 PRODUCTS (Not Applicable) PART 3 EXECUiiON: 3.01 TESTS: A. Tests shall be conducted during the construction period and at completion to determine conformity with applicable Codes and with these Specifications. Tests shall be performed in the presence of the Architect and shall include, but are not limited to the following: 1. Insulation Resistance: Perform 500 -volt D.C. tests for one minute on all feeder conductors, including the neutral, and make a typed record of all readings to be included in the maintenance instructions. Repair or replace circuits showing Tess than 40 megohms resistance to ground. Make tests using Biddle Insulation Resistance Megger, or equal. 2. Ground Resistance: Test ground resistance per IEEE Standard No. 81. 3. Circuits Continuity. Test all feeder and branch for continuity. Test all neutrals for improper grounds. 4. Equipment Operations: Test lighting circuits for correct operation through their control devices. Test electric baseboard heaters for correct operations through their control relays /thermostats. 5. Lighting Control Circuits: Perform operation tests for all lighting circuits. 6. Product Failure: Any products which fail during the tests or are ruled unsatisfactory by the Owner's Representative shall be replaced, repaired, or corrected as prescribed by the Owner's Representative at the expense of the Contractor. Tests shall be performed after repairs, replacements or corrections until satisfactory performance is demonstrated. 7. Physical Inspection of Electrical Equipment and Cables: Inspection shall be made of all equipment to insure proper assembly and construction. 3.02 INSTRUCTIONS AND MANUALS A. Refer to Division 1. B. At the time of completion, an adequate period shall be allotted by the contractor for instruction of building operating and maintenance personnel in the use of all systems. All personnel shall be instructed at one time, the Contractor making all necessary arrangements with manufacturers's representatives. The equipment manufacturer shall provide product literature and application guides for the Users' reference. C. Costs, if any, for the above service shall be paid by the Contractor. 3.03 PROJECT RECORD DOCUMENTS (AS- BUILT) A. Provide Project Record Drawings and Specifications as required by other Sections of Specifications and as required herein. Such drawings shall fully represent installed conditions including actual location of outlets, correct conduit and wire sizing as well as routing, revised fixture scheduling listing the manufacturer and products actually installed. B. All changes to drawings shall be made by qualified draftspersons to match existing line work and lettering as closely as possible. 3.04 WORKMANSHIP A. Preparation, handling and installation shall be in accordance with manufacturer's written instructions and technical data particular to the product specified and /or approved except as otherwise specified. Coordinate work and cooperate with other in furnishing and placing this work. Work to approved shopdrawings for work by others and to field measurements as necessary to properly fit the work. B. Conform to the National Electrical Contractor's Association Standard of Installation for general installation practice. 3.05 SCHEDULE OF WORK: Arrange work to conform to the schedule which has been established for the progress of the work. Advise regarding shipping schedule of major equipment. 3.06 SUPERVISION: Contractor shall personally or through an authorized and competent representative constantly supervise the work form beginning to completion and, within reason, keep the same workmen and foreman on the project throughout the project duration. 3.07 PROTECTION: Keep conduits, junction boxes, outlet boxes, and other openings closed to prevent entry of foreign matter. Cover fixtures, equipment and apparatus and protect against dirt, paint, water, chemical or mechanical damage, before and during construction period. Restore to original condition any fixture, apparatus, or equipment damaged prior to final acceptance. Protect bright finished surfaces and similar items until in service. No rust or damage will be permitted. 3.08 SPECIAL TOOLS: All special tools for proper operation and maintenance of the equipment provided under this section shall be delivered to the Owner's representative. 3.09 CUTTING AND PATCHING A. Install all required sleeves, forms and insets before walls or partition are built. Cutting and patching of walls, partitions, ceilings and floor necessary for reception of work, cause by failure to provide or properly located sleeves, forms and insets, incorrect location of work or failure to cooperate with other trades, shall be done at expense of trade responsible. B. No cutting of finished or structural work may be done without acceptance. When necessary to have finished material or stuctural work cut, finsh necessary drawings to trade whose materials are out to be cut. 3.10 CLEARANCES: Provide working clearance in front of, in back of, and to sides for all electrical equipment as required by National Electrical Code Article 110. 3.11 DEMOLITION: Demolition and removal of existing electrical services to the existing tenant space to be demolished by the Contractor. END OF SECTION SECTION 16100: BASIC MATERIALS AND METHODS The General Conditions, Supplementary Conditions, and Division 1 apply to work under this Section. PART 1 GENERAL 1.01 DESCRIPTION A. Work specified in this section encompasses products, assemblies and basic installation methods required for electrical project systems specified under this Division and includes, but is not limited to: 1. Conduit, raceways, and fittings. 2. Wire and cables. 3. Wire connections and devices. 4. Outlet boxes. 5. Pull and junction boxes. 6. Switches and receptacles. 7. Device plates. 8. Overcurrent protective devices. 9. Telephone terminal backboard. 10. Door buzzer and pushbutton system. 11. Background sound system equipment installation and wiring. 12. Empty raceway provisions for burglar alarm and security system and switches. B. Work Not Included: 1. Background sound system equipment furnished by FDI. 2. Burglar alarm and security system equipment and wiring. 1.01 SUBMITTALS A. Submit in conformance with the requirements 1. Switches, receptacles and device plates. 2. Conductors and cables. 3. Overcurrent protective devices. 4. Raceways. 5. Door buzzers and pushbutton. detection units of Section 16050 the following items: PART 2 PRODUCTS 2.01 CONDUIT AND FITTING A. Rigid Steel Conduit 1. Conduit, rigid steel: full weight, threaded, hot -dip galvanized, inside enameled, conforming to ANSI C80.1. 2. Three -piece couplings: electroplated, cast malleable iron. Efcor 165 series, 0.Z. /Gedney 4 -50 series or equal. 3. Threadless couplings: electroplated, cast malleable iron, with integral conduit stop. Efcor 1760. B. C. 4. Threadless connectors: electroplated, cast malleable iron, on threaded male hub plastic insulated throat rated 90 degrees C minimum. Efcor 17506 series, 0.Z. /Gedney 31 -050 1T series or equal. 5. Insulated bushings: threaded polypropylene or thermosetting phenolic rated 150 degrees C minimum. 6. Insulated grounding bushings: threaded cast malleable iron body with insulated throat and steel, lay --in" ground lug with compression screw. 0.Z. /Gedney BLG series, Thomas & Betts 3870 series or equal. 7. Insulated metallic bushings: threaded cast malleable iron body with plastic insulated throat rated 105 degrees C. 0.Z. /Gedney Type B, Thomas & Betts 1222 series or equal. Electrical Metallic Tubing (EMT) 1. Conduit: Shall be formed of cold rolled strip steel, electrical resistance welded continuously along the longitudinal seam and hot -dip galvanized after fabrication. Conduit shall conform to ANSI C80.3 specifications and shall meet U.L. requirements. 2. Couplings: Electroplated, cast malleable iron, gland compression type, U.L. listed rain and concrete tight through 1 -1/4 inch trade size, 0.Z. /Gedney 6050W series, Efcor 760 series or equal. Set screw type couplings may be used in dry locations, 0.Z. /Gedney 5050 series or equal. 3. Connectors: Gland compression type with cast malleable iron body with male hub and insulated plastic throat 150 degrees C. temperature rated. 0.Z. /Gedney 4050 series or equal. Flexible Metallic Conduit 1. Conduit: Shall be fabricated in continuous lengths from galvanized steel strip, spirally wound and formed to provide an interlocking design. 6' MAX. LENGTH Flexible conduit is not permitted in walls. 2. Fittings: Connectors shall be made of the screw clamp with cast malleable iron bodies and threaded male hubs with insulated throats. D. Liquid Tight Flexible Metallic Conduit 1. Conduit: Anaconda 2. Fittings: Connector iron, with insulated or equal. Type U.A., Coleman Type Uxt1 or equal. body and gland nut shall be of cadmium plated cast malleable throat, MAX. 24 ", T & B 5331 series, 0.Z. /Gedney 4Q-38-1T series, E. Minimum acceptable conduit size shall be 3/4 inch. 2.02 WIRE AND CABLE A. General 1. Acceptable manufacturers: PWC Inc., or equal. General Electric Co., Rome Cable, Southwire, Triangle, 2. Conductor material: All wire and cable shall be insulated copper conductors for all wire sizes. Aluminum wire and cable shall not be used. 3. Insulation: Insulation shall be THWN -THHN for wire sizes through size 1/0 AWG. For larger wire sizes insulation shall be THWN, XHHW, THW or as required to suit application. 4. Fixture wire: Type AF. 5. Minimum conductor size: Power and lighting branch circuits: Signal and control circuits under 100 volts: Any 120V./ 20A. circuits over 75 LF. must be: 2.03 OUTLET BOXES AND COVERS #12 AWG #14 AWG. #10 AWG. A. Standard Outlet Boxes: Galvanized, one - piece, drawn steel, knock -out type of size and configuration best suited to the application indicated on the plans. Minimum box size, 4 inch square by 1 -1/2 inch deep. B. Switch Boxes: Two inch by 3 -inch long, galvanized steel switch boxes shall be used only for the installation of single switches, Install multiple switches in standard gang boxes with raised device covers suitable for the application indicated. 2.04 SWITCHES AND RECEPTACLES A. General: Color of devices shall be white at painted walls, ivory when installed in fixtures, and orange for dedicated I.G. receptacles unless otherwise noted on Drawings. 1. All general purpose 15 and 20 ampere, 125 -250 volt receptacles and 120 -277 volt switches shall conform to NEMA WD 1 and applicable U.L. tests. B. Receptacles: 1. Ground fault circuit interrupter receptacle: NEMA type 5 -15R LEVITON #6598 -1 or equal. 2. Duplex receptacles: NEMA type 5 -15R, and 5-20R, heavy duty specification grade, side wired only, LEVITON #5242 -W AND 5243 -W or equal. 3. Cash register receptacles: NEMA type 5 -20R, heavy duty specification grade, side wired only, Hubbell #IG -5262, provided with green insulated ground wire, and with engraved cover plate "For Cash Registers Only ". C. Switches: Twenty ampere, 120 -277 volts, fast make -slow break, quiet type switch with silver cadmium alloy contacts, binding head terminal screws, side wired only. All switches shall be white in color. 1. Single pole, single throw, LEVITON #1221 -W or equal. 2. Three -way, LEVITON #1223 -W or equal. 2.05 DEVICE PLATES A. Flush Device Plates: Plates shall be smooth plastic, color, LEVITON #8600 series or equal. B. Surface Mounted Devices, indoor: Galvanized metal to fit box. C. Outdoor, Weatherproof: Die cast aluminum construction, corrosion resistant, heavy duty, hinged cover flap, and gasket, LEVITON #6196, horizontal mounting. 2.06 DISCONNECT SWITCHES A. Switch Interior. Dead-front construction with hinged arc suppressor and switch blades which are fully visible in the "OFF " position and with door open. B. Switch Mechanism: Quick -make and quick -break operating handle and mechanism with dual cover interlock to prevent unauthorized opening of the switch door in the "ON" position or closing the switch mechanism while the door is open. C. Ratings: Switches shall be horsepower rated for the operating voltage and with fused or non -fused arrangements as shown on the drawings. D. Enclosures: NEMA 1, code gauge sheet steel with hinged cover, or NEMA 3R as shown on Drawings, and as required by application. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 7 2008 City of Tukwila B . ILDING DIVI ION RECIVED cyry OFETUKWIL A FEB 19 Z008 �E�{lvl►1 CENTER DATE: 1 -28 -08 JOB NO: 07142 DRAWN: JP CHECKED: JL 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 SOUTHCENTER WESTFIELD SOUTHCENTER MALL V) t0 TUKWILA, WA EXPIRES 06 -23-08 EIMMIESEMEMEI REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 ELECTRICAL SPECIFICATIONS SHEET NUMBER OPI�T E - 5 ELECTRICAL ENGINEERING. INC 1786 Augusta Ln Ste B, Yuba City, CA 95993 Pk 530.790.0620 Fax 530.6719792 ELECTRICAL SPECIFICATIONS (con't) 2.07 TRANSFORMERS A. Transformers shall be indoor type, self cooled, 480V, three - phase, dual winding, fully enclosed, ventilated, general purpose dry type, 480 volt primary, 120/208 volt secondary, 60 hertz, equipped with two 2 1/2% full capacity taps above and below rated voltage and shall be of the KVA rating shown on the drawings. B. Transformers shall have copper or aluminum windings Class 'H' insulation group, with temperature rise, when operated continuously at full load and rated frequency, not exceeding 150 degree C. rise over 40 degree C. ambient, unless mentioned otherwise on the one line diagram. C. Transformer shall have a minimum of 10% overload capacity at rated voltage and shall have a 10 KV BIL rating. D. Sound level at any load shall not exceed 45 dB when tested in a room with ambient sound level not exceeding 24 dB. Ecessively noisy transformers shall be replaced. E. Transformer impedance shall not be less than 4% nor greater than 5 %. Transformers shall conform to NEMA TRI-1974, NEC 450 -21 and all applicable state and local codes. F. Transformer shall not contain any PCB's (Polychlorinated Biphenyls). G. Transformer size shall fit space allocated per Drawings. 2.08 PANELBOARDS A. Ratings: See panel schedules. B. Finish: All painted steel work shall be treated with a primer coat and finish coat of the manufacturer's standard gray color or ANSI 61. C. Bussing 1. Bussing shall be rectangular cross section full length tin plated 2. Each panelboard shall be equipped with a ground bus secured to the interior of the enclosure. The bus shall be equal to the panelboard neutral bus and shall have a seperate lug for each ground conductor. Not more than one conductor shall be installed per lug. 2.09 PROTECTIVE DEVICES A. Circuit Breakers: Molded case, bolt -on, thermal magnetic type, 40 degrees C. ambient temperature compensated, fixed mounting, with quick -make and quick -break switching mechanism mechanically trip -free from the operating handle. B. Ratings: Refer to drawings and panel schedules for trip frame and poles required. Minimum short circuit rating for 120/240 volt breakers is 10,000 A, 277/480 volt breakers is 22,000 A, if not indicated otherwise. C. Manual motor starters: Fractional H.P. 1 phase motors shall be protected by thermal 01. relay integral with the disconnect: "Motor- Minder ", or equal. 2.10 ELECTRICAL SUPPORTING DEVICES A. Conduit Straps: Hot -dip galvanized, cast malleable iron, one hole type strap with cast clamp-backs and spacers as required. O.Z. /Gedney #14 -500 strap and #1410 spacer, Refcor #231 strap and #131 spacer, or equal. B. Construction Channel: 1-1/2 inch by 1-1/2 inch 12 gauge galvanized steel channel with 17/32 inch diameter bolt holes, 1-1/2 inches on center, in base of the channel. Kindorf 905 series, Unistrut P- 1000 -HS, or equal. C. Fasteners (General): Wood screws for fastening to wood. Machine screws for fastening to steel. Toggle bolts for fastening to hollow concrete block, gypsum board or plaster wall. Expansion anchors for attachments to pre - poured concrete. 2.11 IDENTIFYING DEVICES A. Panelboard Directories: Shall be typewritten, arranged in numerical order and shall show the number of the circuit is indicated. The room numbers used shall be verified with the Owner and shall not necessarily be those used in the drawings. Mount directories in a 6" x 8" metal frame under plexiglass inside each panelboard. B. Wire & Terminal Markers: Self -- adhering, pre-printed vinyl with self - laminating wrap ground strip Brady B191 series, Thomas & Betts WSI series, or equal. 2.12 PLYWOOD BACKBOARDS A. Where indicated for telephone or communication system terminals, or for motor control or other equipment assembles, provide backboards of size indicated. 1. Use Douglas Fir plywood, exterior grade with "B" face, prime and finished painted. 2. Unless otherwise indicated, provide 3/4 inch thick plywood. 3. All plywood shall be fire resistant. 2.13 GROUNDING A. Enclosures of equipment, raceways, and fixtures shall be permanently and effectively grounded. Provide code- sized, (unless otherwise indicated) copper, insulated green equipment ground with all branch and feeder circuit runs. Equipment ground shall originate at panelboard ground bus and shall be bonded to all switch and receptacle boxes and electrical equipment enclosures. B. Building services shall be grounded to building steel and to cold metallic water piping. C. Isolated ground conductors shall terminate on isolated ground bus and receptacle isolated ground lugs only. 2.14 DOOR BUZZER AND PUSHBUTTON SYSTEM A. Provide a complete and operating door buzzer system with all necessary accessories, transformer and wiring. B. Buzzers, three required, shall be Edwards #1064 -05, mounted 8' AFF in stock and mezzanine areas, and 2' AFF under cash wrap counter. C. Pushbutton shall be Edwards #1786 -B, mount at 4' AFF. D. Transformer rated 20 VA, 24VAC shall be Edwards #592, mount at 8' AFF, and connect to local general purpose receptacle circuit. PART 3 EXECUTION 3.01 CONDUIT AND RACEWAY APPLICATIONS A. Rigid Steel Conduit: For all exposed and U/G conduit exposed to mechanical damage. Minimum size is 3/4 ". B. Electrical Metallic Tubing (EMT): Interior power and lighting branch circuits where run concealed above suspended ceiling, in stud walls, furred spaces, and where not exposed to mechanical damage, or above 6' from floor. C. Flexible Metallic Conduit: In dry locations connection to transformers, (6' MAX.), vibrating equipment (24" MAX.), and to recessed lighting fixtures. D. Liquid -Tight flexible Metallic Conduit: In damp and wet locations for connection to all pump motors, solenoid valves, HVAC equipment and similar devices shall be made using liquidtight flexible metallic conduit. Provide separate ground wire independent of conduit, run inside conduit and bonded at both ends to enclosures. Maximum length of 24 inches. 3.02 CONDUIT INSTALLATION A. General 1. Conduit system shall be concealed unless exposed work is clearly called for on drawings. 2. Conduits shall be tightly covered and well protected during construction using metallic bushings and bushing pennies to seal open ends. 3. In all empty conduits or ducts, install a 200 -pound tensile strength polyethylene pulling rope. 4. Conduit systems shall be electrically continuous throughout. Install code size, insulated, copper, green grounding conductor in all conduit runs pulled with phase and netural conductors. B. Layout 1. Locations of conduit runs shall be planned in advance of the installation and coordinated with the ductwork, plumbing, ceiling and wall construction in the same areas and shall not unnecessarily cross other conduits or pipe, nor prevent removal of ceiling or tiles or panels, nor block access to mechanical or electrical equipment. 2. Where practical, install conduits in groups, in parallel, for vertical and horizontal runs and at elevations that avoid unnecessary offsets. 3. Exposed conduit shall be run parallel or at right angles to the centerlines of columns and beams. 4. Conduits shall not be placed closer than 12 inches from a parallel hot water or steam line or 3 inches from such lines crossing perpendicular to the runs. C. Supports 1. All raceway systems shall be secured to the building structures using specified fasteners, clamps and hangers spaced according to code requirements. 2. Support single runs of conduit using one hole pipe straps. Where run horizontally on walls in damp or wet location, install "clamp- backs' to space conduit off the surface. 3. Multiple conduit runs shall be supported using "trapeze" hangers fabricated from specified construction channel, mounted to 3/8 inch diameter, threaded steel rods secured to building structures., Fasten conduit to construction channel with standard one hole pipe clamps or the equivalent. D. Termination and Joints 1. Raceways shall be joined using specified coupling or transition couplings where dissimilar raceway systems are joined. 2. Conduits shall be securely fastened to cabinets, boxes and gutters using two locknuts and an insulating bushing or specified insulated connectors. Install grounding bushings or bonding jumpers on all conduits terminating at concentric knockouts. 3. Conduit terminations exposed at weatherproof enclosures and cast outlet boxes shall be made watertight using specified connectors and hubs. 4. Install expansion couplings where any conduit crosses a building separation or expansion joint. E. Penetrations 1. All floor penetrations shall be sealed water - tight. Maintain fire rating as required. 2. Fire -safe all rated wall penetrations using 3M listed fire - safing sealants and assemblies. 3.03 CABLE AND WIRE INSTALLATION A. General 1. Conductors shall not be installed in conduit until all work of any nature that may cause damage is completed. Care shall be taken in pulling conductors that insulation is not damaged. U.L. approved non - petroleum base and insulating type pulling compound shall be used as needed. 2. All cables shall be installed and tested in accordance with manufacturer's requirements and warranty. B. Splicing and Terminating 1. All aspects of splicing and terminating shall be in accordance with cable manufacturer's published procedures. 2. Make up all splices in outlet boxes with connectors as specified herein with separate tails of correct color to be made up to splice. Provide at least six (6) inches of tails packed in box after splice is made up. 3. All wire and cable in panels, terminal cabinets and equipment enclosures shall be bundled and clamped. C. Metallic sheathed type MC Cable: Installed for branch circuit wiring as allowed by local building code and tenant manual. Cable shall not be run exposed in finished spaces. Cable shall be supported in accordance with NEC article 334. Use only U.L. listed fittings for terminations at boxes and cabinets. 3.04 INSTALLATION OF BOXES AND WIRING SERVICES A. General 1. All outlets shall finish FLUSH with building walls and ceiling, except where exposed work is called for. There shall be no gap between box and wall or ceiling material. Any opening between box and wall or ceiling shall be caulked airtight. 2. Install raised device covers on all outlet boxes as required to finish flush with surface. Covers shall be of a depth to suit the wall or ceiling finish. 3. Leave no unused openings in any box. Install close -up plugs as required to seal openings. 4. Exposed outlet boxes and boxes in damp and wet locations shall be cast metal with gasketed cast metal cover plates. B. Boxes Layout 1. Outlet boxes shall be installed at the locations and elevations shown on the drawings or specified herein. Make adjustments to locations as required by structural conditions and to suit coordination requirements of other trades. 2. Outlet boxes in stud wall and partitions shall not be mounted back -to -back nor shall through -wall boxes be permitted. C. Supports 1. Boxes installed in stud walls shall be equipped with brackets designed for attaching directly to the studs or shall be mounted on heavy gauge galvanized steel box supports. 2. Fixture outlet boxes installed in suspended ceilings of gypsum board or lath and plaster construction shall be mounted to 16 gauge metal channel bars attached to main ceiling runners. 3. Fixture outlet boxes installed in suspended ceilings systems supporting acoustical tiles or panels shall be supported directly from the structures above wherever pendant - mounted fixtures are installed from the box. D. Mounting Heights: Mounting heights from finished floor to center line of device box shall be as follows, and in accordance with handicapped accessibility requirements of State Code. Device: Height(inches) Convenience receptacle 15 Convenience receptacles above Counters unless otherwise noted 36 Switches, light 48 Telephone outlet, wall 15 3.05 TRANSFORMER INSTALLATION A. Transformer shall be floor mounted as shown on the drawings. Furnish and install all mounting hardware to safely carry the weight of the transformer. Maintain adequate spacing for ventilation as recommended by the manufacturer and required by code. B. Provide Korfund type vibration isolation pads for each transformer. C. Connections to transformer shall be made with flexible metallic conduit. Install ground conductors in each conduit and provide grounding bushings as required. D. Provide heat insulating barrier below transformer where installed on combustiable surface. END OF SECTION SECTION 16510: LIGHTING FIXTURES PART 1 1.01 A. A. GENERAL DESCRIPTION Work Included 1. Installation and connection of all fixtures, lamps, ballasts, lighting control devices, relays, related components and accessory wiring as shown on the plans, Fixture Schedule or as specified herein. 2. Owner to provide lighting fixtures and lamps. Contractor to install all lighting fixtures and lamps. 3. Final aiming and adjustment of recessed adjustable fixtures and track mounted fixtures shall be by the Electrical Contractor, as directed by the Owner's Representative. Related Work Specified Elsewhere: Refer to Section 16050 for requirements applicable to this Section. 1.02 COORDINATION: Refer to Architectural Plans for exact location of lighting fixtures. 1.03 SUBMITTALS: Submit in conformance with the requirements of Section 16050: Time switches, control devices, relays and cabinets and wiring diagrams. PART 2 PRODUCTS 2.01 LAMPS A. B. Incandescent Lamps: General purpose A base lamps shall be inside frosted, rated 120 VAC, or as noted on Fixture Schedule. Reflector style lamps, R and PAR, as noted on Fixture Schedule. MR16 lamps shall be G.E. Precise constant color type. Fluorescent Lamps 1. 24, 36 and 48 inch long lamps shall be T-8 energy saving DELUXE warm -white 735 K in color. 2. Compact twin -tube and double twin -tube, 9, 13 and 18 watts nominal, 735 K SPX35. C. Lamps shall be as manufactured by G.E., Osram, Venture, Sylvania only. 2.02 BALLASTS A. Fluorescent Lamp Ballasts 1. Ballasts for all single tube fluorescent lamps shall be U.L. approved, CBM certified or ETL tested, Class P, Sound Rated A, "full- output energy- saving, electronic ballasts for Octron lamps as manufactured by Magnetek. 2. Ballasts for compact fluorescent lamps shall have high power factor. 3. Ballasts shall be approved for use with energy saving lamps by the lamp manufacturer. 2.03 REFRACTORS, REFLECTORS AND LOUVERS A. All glassware, plaster and metal shall be uniform, free from defects, and photometrically tested for distribution by an independent testing laboratory. B. C. Plastic diffusers shall be of virgin acrylic plastic. Polished reflectors used with triphosphor compact lamps shall have anti-iridescent optical coating. 2.04 LIGHTING CONTROL SYSTEM A. Lighting Control system shall consist of 20A mechanical latching type lighting contactors, interconnecting wiring, a master switch station, time clocks and switches all housed within a Nema 1 enclosure. B. Lighting Contactor shall be housed in a code gage cabinet with time clocks and have hinged screw cover. Provide one or more as required cabinets Hoffman, or equal. Provide one or more Lighting Contactors as required m'Square -D" 8903 or equal. C. Master switch station shall consist of 20A, 120/277VAC momentary contact single pole double throw, center OFF, toggle switches, Hubbell #1557 -I and multiple channel outputs, or equal. Quantity as indicated on Drawings. Provide engraved multigang stainless steel cover plate for switches. 2.05 TIME SWITCHES A. Time switches shall be programmable 7 -Day, 24 hour electronic type with backup battery as manufactured by Tork, Rainbird, or Intermatic. Time switches shall be wired to control lighting via Lighting contactors of lighting control system. Typical for HVAC system. PART 3 EXECUTION 3.01 INSTALLATION A. Contractor shall be responsible for handling, and fixtures shall be plumb, level, in straight lines without distortion and clean. B. Install each fixture in a manner recommended by the fixture manufacturer and approved by the Owner's Representative. Under this Section of the work, furnish and install all additional ceiling bracing, hanger supports and other structural reinforcements to the building require to properly and safely suspend fixtures, all as approved by the Owner's Representative. C. Fixtures in areas of exposed duct and pipe work shall be suspended to avoid conflict with same. D. Pendant fixtures shall be provided with ball aligners and sway adapters. Fixture chain shall not be used for supporting fixtures. E. Ballasts: Ballasts judged by the Owner's Representative to be noisy, and failed or malfunctioning ballasts shall be replaced at Owner's expense. 3.02 FIXTURE SUPPORT - SUSPENDED CEILINGS A. Provide four wire supports for each suspended fixture, secured to the building structure independent of the ceiling supporting system. END OF SECTION CODE CON1PLIPICE APR _ 2 0 City Of 'Tukwila CS ILDD1G DNI 10% fl,OSH tec RECEIVED CITY OF TUKWILA FEB 19 2008 PEF1MIT CENTER DATE: 1-28-08 JOB NO: 07142 DRAWN: JP CHECKED: JL 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 SOUTHCENTER 0 LLI LL (.% ) LLI SOUTHCENTER MALL CD 1 00 00 00 EXPIRES 06 -23-08 REVISIONS ISSUED FOR PERMIT /CONSTRUCTION 28 JAN. 08 ELECTRICAL SPECIFICATIONS MSMENIMMEEMEIM SHEET NUMBER OP.FIT E - 6 ELECTRICAL ENGINEERING, INC 1786 Augusta Ln Ste 6, Yuba City, CA 95993 Ph: 530.790.0620 Fax 530.671.9792