HomeMy WebLinkAboutPermit D06-139 - Makaafi Residence - AdditionMAKAAFT RESIDENCE
13350 37 AV S
EXPIRED 12 - 02 - 06
D06 -139
•
•
•
•
•
Tenant:
Name:
Address:
Owner:
Name:
Address:
Contact Person:
Name:
Address'
Contractor:
Name:
Public Works Activities:
Fire Loop Hydrant:
Flood Control Zone:
Hauling:
Land Altering:
Landscape Irrigation:
Moving Oversize Load:
Sanitary Side Sewer:
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter:
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7340601023
Address: 13350 37 AV S TUKW
Suite No:
Address:
Contractor License No:
MAKAAFI RESIDENCE
13350 37 AV S, TUKWILA WA
MAKAAFI PILISITA
13350 37 AV S, TUKWILA WA
ANA PULOKA
13350 37 AV S, TUKWILA WA
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
OWNER AFFIDAVIT ON FILE - ANA PULOKA
DESCRIPTION OF WORK:
CONVERT SHED AND CARPORT INTO A 326 SF (2 -ROOM) ADDITION
Value of Construction: $28,697.78
Type of Fire Protection: AUTOMATIC FA
Type of Construction: VB
N
N
N
N
N
N
N
N
N
N
N
N
DEVELOPMENT PERMIT
Number: 0
Start Time:
Volumes: Cut
Start Time:
Private:
Profit: N
Private:
** Continued Next Page **
Permit Number:
Issue Date:
Permit Expires On:
Expiration Date:
Phone:
Phone: 206 246 -4354
Phone:
D06 -139
06/05/2006
12/02/2006
Fees Collected: $887.35
Uniform Building Code Edition:
Occupancy per UBC: 22
Size (Inches): 0
End Time:
0 c.y. Fill 0 c.y.
End Time:
Public:
Non - Profit: N
Public:
D06 -139 Printed: 06 -05 -2006
Permit Center Authorized Signature:
I hereby certify that I have read and
is permit and know the same to be true and corr@Pt. All provisions of law and
ordinances governing this work will be with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws
regulating constructioryorthe perform apsie of work. I am authorized to sign and obtain this development permit.
doc: Devperm
City of Tukwila
Department of Community Development / 6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Signature: // / i
Print Name: &na / ` 0 "mil .
Date:
Date: — ® - 0_6
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is
suspended or abandoned for a period of 180 days from the last inspection.
D06 -139 Printed: 06 -05 -2006
City of Ttwila
Parcel No.: 7340601023
Address: 13350 37 AV S TUKW
Suite No:
Tenant: MAKAAFI RESIDENCE
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: ri.tukwtla.wa.us
1: ***BUILDING DEPARTMENT CONDITIONS***
PERMIT CONDITIONS
Steven M. alions1/4 Mayor
Steve Lancaster, Director
Permit Number: D06 -139
Status: ISSUED
Applied Date: 04/18/2006
Issue Date: 06/05/2006
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any
requirements for special inspection.
7: All wood to remain in placed concrete shall be treated wood.
8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building
inspector. No exception.
9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
10: Manufacturers installation instructions shall be available on the job site at the time of inspection.
11: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the
International Building Code and the Washington State Ventilation and Indoor Air Quality Code.
13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the Cityof Tukwila
Permit Center.
14: All electrical work shall be Inspected and approved under a separate permit issued by the Washington State Department
of Labor and Industries (206/248- 6630).
15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: Conditions
D06 -139 Printed: 06 -05 -2006
City of Ti1a
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431 -3670
Fax: 206 -431 -3665
Web site: tt.tukwifa.wa. us
Steven M. A7w t, Mayor
Steve Lancaster, Director
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws
regulating construction or the performance of work.
Signature:
Print Name:
doc: Conditions
6)74 /1- 6-( 7o/c
Date: & r ' Sr
D06 -139 Printed: 06-05-2006
Name:
Mailing Address:
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
CONTACT PERSON
King Co Assessor's Tax No.: N7 i
/335 X37' Ave S • , 772,64)/c4 90'47 Suite Number:
New Tenant:
Site Address:
Tenant Name: //��
Property Owners Name: /?t 6/7 Akita t+/
Mailing Address: /33 50 3 1'- � S i 'ems CAI 4) 9 9 rJ
City. state
ate a 'dice is_r
Q City State Zip
E-Mail Address: /'r1A��u /p � �i C Cr /�S�Q //, l B/n Fax Number:
'GENERAL CONTRACTORINFORMATION
icoatracttirannfortnrtidn for Meehanical:(pg ;for Plumbing and Gas Piping (pg 5))"�
Company Name:
Mailing Address:
State
City
Day Telephone:
Fax Number:
Contractor Registration Number: Expiration Date:
CHITECT OF RECORD -- All plans must be wet stamped by Architect of Record
Contact Person:
E -Mail Address:
Company Name:
Mailing Address:
Zip
Contact Person:
E-Mail Address:
a ENO ER OF RECORD = All plans Must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E-Mail Address:
Q:\Application.Woma- Applidom on LineV -7006 - Permit Appac.tion.doc
Revised: 47006
bb
Building Permi
Mechanical Permi
�t.
Plumbing /Gras Permi No.
Public Works Permi Igo.
Project No.
8r ifce nce
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
U/d — IDZL{
Floor:
D .... Yes
Zip
Day Telephone: `26 ' 04 //'' y.3-
..No
Zap
City
Day Telephone:
Fax Number:
State
City
Day Telephone:
Fax Number:
State
Zip
Page t of 6
Valuation of Project (contractor's bid price): $ 2O VDa Existing Building Valuation: $ tlD
Scope of Work (please provide detailed information): Cow/v(1 3,68 s and arfin f fort& R 2.0 ,„,„„
a do![ ho •
Will there be new rack storage? ❑ .. Yes Elergr (If yes, a separate permit and plan submittal will be required)
Provide All Building Areas in Square Footage Below ,.
in Floor
2fla Floor
;Floor
Floors that
Basement
Accessory, Structure*
Attached. Garage
Detached garage
Attached Carport
tached Catport
CpverettDeck..
Uncovered Deck
Existing
/
Interior
Remodel
Addition to
Existing
26,
New
Type o£
Construction
per IBC
Type of
Occupancy per
IBC
PLANNING DIVISION:
Single - family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): '6 Floor area of principal dwelling: Floor area for accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ ....Yes No If "yes ", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0.. Sprinklers p<lutomatic Fire Alarm ❑..None ❑ . Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .. Yes BCC
No
If "yes", attach list of materials and storage locations on a separate 8 -1/2 x 11 paper indicating quantities and Material Safety Data Sheets.
SEPTIC SYSTEM:
❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
Q: AppliationseFomu- Applications On Line- 2006 - Permit Appliation.doc
Revised: 4-2006
bh
Page 2 of 6
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Drinking fountain or water
cooler (per head)
Wash fountain
Gas piping outlets
Bidet
Food -waste grinder,
commercial
Receptor, indirect
waste
Clothes washer, domestic
Floor drain
Sinks
Dental unit, cuspidor
Shower, single head trap
Urinals
Dishwasher, domestic,
with independent drain
Lavatory
Water Closet
Building sewer or trailer
park sewer
Rain water system — per
drain (inside building)
Water heater and/or
vent
Industrial waste
pretreatment interceptor,
including its trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of water
piping and/or water treating
equipment
Repair or alteration
of drainage or vent
piping
Medical gas piping system
serving one to five
inlets/outlets for specific
gas
Additional medical gas
inlets/outlets — six or more
PLUMBING AND GAS PIPING PERMIT INFORMATION - 206-431 -3670
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City State Zip
Day Telephone:
Fax Number:
Expiration Date:
Contact Person:
E -Mail Address:
Contractor Registration Number:
•
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below:
QMppliatiouWonu- Applications On Lin U- 2006 -Penult Appliutian.doc
Revised: 4-2006
bb
Page 5 of 6
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW �r�• OR AUTHORIZED AGE :
Signature: Date: '' l� 19,4
Print Name:
Mailing Address:
Date Application Expires:
Date Application Accepted:
t l/ St�Q / t k -441
Da Telephone: 19 . 6• V33
/3 3 s 7` G,u-e r- ,o,'c' ,9 9'8/6
City State Zip U
og
Q:Upplicatiwu\Fonna- Applications On Line- -2006 - Permit Application.dac
Revised: 4-2006
bb
Staff Initials:
Page 6 of 6
City of Tukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7340601023
Address: 13350 37 AV S TUKW
Suite No:
Applicant: MAKAAFI RESIDENCE
Receipt No.: R06 -00791 Payment Amount: 539.56
Initials: JEM Payment Date: 06/05/2006 01:56 PM
User ID: 1165 Balance: $0.00
Payee: ANA H. PULOKA
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 1180 539.56
ACCOUNT ITEM LIST:
Description
Current Pmts
BUILDING - RES
STATE BUILDING SURCHARGE
RECEIPT
Account Code
000/322.100 535.06
000/386.904 4.50
Permit Number D06 -139
Status: APPROVED
Applied Date: 04/18/2006
Issue Date:
Total: 539.56
6093 06/05 9716 TOTAL 539.50
dm: Receipt Printed: 06-05 -2006
City of T ukwila
6300 Southcenter BL, Suite 100 / Tukwila, WA 98188 / (206) 431 -3670
Parcel No.: 7340601024
Address* 13350 37 AV S TUKW
Suite No:
Applicant: MAKAAFI RESIDENCE
Receipt No.: R06 -00529 Payment Amount: 347.79
Initials: JEM Payment Date: 04/18/2006 02:47 PM
User ID: 1165 Balance: $539.56
Payee: PILISITA S. MAKAAFI
TRANSACTION LIST:
Type Method Description
Amount
RECEIPT
Payment Check 1120 347.79
ACCOUNT ITEM LIST:
Description
Current Pmts
PLAN CHECK - RES
Account Code
000/345.830 347.79
Permit Number: D06 -139
Status: PENDING
Applied Date: 04/18/2006
Issue Date:
Total: 347.79
4674 04/18 9716 TOTAL 347.79
doc: Receipt Printed: 04 -18 -2006
Page 1 of 5
Printed i128/2006
Fpm • DCD MOO
3
Floor Insulation: Floor Insulation shall be installed In a permanent manner in substantial contact with the surface being
insulated. Insulation supports shall be Installed so spacing Is not more than 24 inches on center. Installed insulation shall
not block the air flow through foundation vents.
2004 WSEC 1311.4
Source Specific Ventilation: Source specific exhaust ventilation is required In each kitchen, bathroom, water closet,
laundry room, Indoor swimming pool, spa, and other rooms where excess water vapor or cooking odor is produced. For
source specific ventilation capacity see table 3-1 2004 WSVIAC.
2004 WSVIAC
302.2.1
Minimum ventilation openings for crawispace and attic openings shall be 1 sq. foot per 150 sq. foot of space.
R408(CrawlSpacs)
IRC R806.3 (ATTIC)
Openings for under-floor ventilation. Minimum net area of ventilation opening shall net be less than 1 square foot for
each 150 square feet of under -floor area. Openings shall be within 3 feet of each corner of the building.
IRC 8408.2
BATHROOMS
4
Bathrooms shall be provided with aggregate glazing area in windows of not less than 3 square feet, one-half of which
must be open able.
R303.3
Exception: The glazed areas not required where artificial light and a mechanical ventilation system are provided. Minimum
ventilation rate shall be 50 dm... vented to the outside
Bathrooms shall have a minimum ceiling height of 6 feet 8 inches over the fixture and at the front clearance area for
fixtures.
8306.1
E
Bathtub and shower walls surface shall be finished with a nonabsorbent surface and extend to a height of not less than
8 feet above the floor.
83073
Mechanical Ventilation: Exhaust air from bathrooms and toilet rooms shall not be re- circulated within a residence or to
another dwelling unit.
M1506.2
Ventilation rate. Ventilation systems shall be designed to have the capacity to exhaust the minimum air flow rate
determined In accordance with Table 1506.3.
Bathrooms — Toilet Rooms Mechanical exhaust capacity of 50 dm Intermittent or 20 dm continuous.
M1506.3
EGRESS WINDOWS, HALLS, STAIRS, RAILINGS
5
Basements with habitable spaces and every sleeping room shall have at least one open able emergency escape and
rescue opening. Opening sill height shall be no more than 44 Inches above the floor.
R310.1
Minimum clear opening shall net clear 5.7 square feet.
R310.1.1
I`
Minimum opening height shall net 24 inches.
R310.1.2
ilsor
Minimum opening width shall net 20 Inches.
R310.1.3
I°
Openings shall be open able from the Inside without the use of keys or tools.
R310.1.4
!ham"
6
Window wells horizontal area shall be 9 square feet with • min. horizontal projection and width of 38 inches and shall
allow emergency escape and rescue opening to be fully opened. Window wells with a vertical depth greater than 44 Inches
shall be equipped with a permanently affixed ladder or steps, ladder or rungs shall have an Inside width of at least 12
Inches, shall project at least 3 inches out from the wall and spaced not more than 18 inches on center vertically the full
height
R310.2
7
Under stair protection. Enclosed accessible space under stairs shall have walls, under stair surface and any soffits
protected on the enclosed side with 1/2 -Inch gypsum board.
R311.2.2
8
Minimum hallway width shall be 36 inches.
R311.3
9
Exit doom required: Not less than one exit door shall be required...provide direct access from habitable portions of the
dwelling to the exterior with out requiring travel through a garage.
R311.4.1
Required exit door shall be hinged, 36 Inches minimum width, 8 feet 8 inches minimum height.
8311.4.2
There shall be a floor or landing on each side of each exterior door.
R311.4.3
0
Headroom. The minimum headroom in all pads of the stairway shall not be less than 8 feet 8 Inches measured vertically
form the sloped plane adjoining the tread nosing or from the floor surface of the landing or platform.
R311.5.2
(DOD H011)
Stair risers. The maximum riser height shall be 7-314 Inches, measured vertically between leading edges of the adjacent
treads. The greatest riser height with any flight of stairs shall not exceed the smallest by more than 3/8 Inches.
8311.5.3.1
(DCD H011)
Stair treads. The maximum tread depth shall be 10 Inches measured horizontally between the vertical planes of the
foremost projection of adjacent treads and at a right angle to the tread's leading edge..
8311.5.3.2
(DCD H011)
Profile. The radius of curvature at the leading edge of the tread shall be no greeter than 9/16 inch. A nosing not less than
3/4 Inch but not more than 1 -1 /4 inch shall be provided on stairways with solid risers. The greatest nosing projection shall
not exceed the smallest nosing projection by more than 3/8 Inch between two stories, Including the nosing at the level of
the floors and landings. Beveling of nosing shall not exceed 1/2 inch. Risers shall be vertical or sloped from the underside
of the leading edge of the tread above at an angle not more than 30 degrees from the vertical. Open risers are permitted
provided that the opening between treads does not permit the passage of a 4 -Inch diameter sphere.
Exception:
1. A nosing is not required where the tread depth is a minimum of 11 Inches.
2. The opening between adjacent treads Is not limited on stairs with a total rise of 30 Inches or less.
8311.5.3.3
(DCD H011)
Landings. There shall be a floor or landing at the top and bottom of each stairway. EXCEPTION: A floor or landing Is not
required at the top of an interior flight of stairs, provided a door does not swing over the stairs. A flight of stairs shall not
have a vertk al rise greater than 12 feet.
R311.5.4
(DCD H011)
Handrail height, measured vertically from the sloped plane adjoining the tread nosing , or finish surface of ramp slope,
shall be not less than 34 Inches or more than 38 Inches to top of the handrail.
8311 .5. and
R
(CCD H011)
Page 2 of 5
Printed 05/26/2006
Fam a DC0 AIOO
1 O
Handrails shall be continuous for the full flight of the stairs.
R311.6.6.2
(DCD H011)
Porches, balconies or raised floor surfaces located more than 30 Inches above the floor or grade below shall have guards
not less than 36 Inches M height.
R312.1
(DCD H011)
Guard openings shall have intermediate rails or ornamental closures which do not allow passage of a sphere 4 inches or
more in diameter.
R312.2
(DCD H011)
SMOKE ALARMS
11
Smoke alarms shall be installed in: each sleeping room, outside each separate sleeping area In the immediate vicinity of
the bedrooms, on each story of the dwelling Including basements but not crawl spaces.
Exception: Smoke alarms In existing areas shall not be required to be Interconnected and hard wired where the
alterations or repairs do not result In the removal of interior wag or ceiling finishes exposing the structure, unless there is
an attic, crawispace, or basement available which could provide access for hard wiring and interconnection without the
removal of Interior flashes.
R313.1
The required smoke alarms shall receive their primary power from the building wiring and when primary power is
Interrupted, shall receive power from a battery.
R313.2
When Interior alterations , repairs or additions requiring a permit occur, or when one or more sleeping moms are added
or created M dwellings, the Individual dwelling unit shall be provided with smoke alarms located as required for new
dwellings; interconnected and hardwired.
R313.1.1
MECHANICAL
12
Appliances access for inspection service, repair and replacement. Appliances shall be accessible for inspection, seMen,
repair and replacement without removing permanent construction. Thirty inches of working space shall be provided In front
of the control side to service an appliance, Room heaters shall be allowed 18 inches working space with no platform
required.
IRC M1306.1
13
Central furnace within compartments or alcoves shall have a minimum working space of 3 Inches along the sides, back
and top with a total width of the enclosing space being at least 12 inches wider than the furnace. Furnaces having a
firebox open to the atmosphere shall have at least a 6 -inch working space along the front combustion chamber side.
Combustion air opening at the rear or side of the compartment shall comply with the requirements of Chapter 17.
IRC M1305.1.1
Appliances Installed In • compartment, alcove, basement or similar space shall be accessed by an opening or door and
an unobstructed passageway measuring not less than 24 inches wide and large enough to allow removal of the largest
appliance M the space, provided that a level service space of not less than 30 inches, is present at the front or service
side of the appliance with the door open.
IRC M1306.1.2
Protection from Impact Appliances located In a garage or carport shall be protected from Impact by automobiles. (2000
lb. Impact load capacity)
IRC M1307.3.1
IBC 1607.7.3
Outdoor combustion air shall be provided through opening's) to the outdoors in accordance with Section G2047.6.1 or
0204.62 . The minimum dimension of air openings shall be not less than 3 inches.
IRC 02407.6
(304.6)
Combustion air openings. Two permanent opening method, one commencing 12 inches from the top and one 12 Inches
from the bottom of the enclosure... commencing directly by duct to the outdoors. Each opening shall have a minimum free
area of 1 square inch per 4.000 Btulh of total input rating of all equipment in the enclosure.
IRC 02407.6.1
(304.8.1)
Appliance located In attics or crawl space shall have access openings and a clear space and unobstructed passage
way large enough to allow removal of the largest appliance, but not less than 30 inches high and 22 inches wide and not
more than 20 feet M length when measured along the center line of the passage way from the opening to the appliance.
IRC Section M
1306 IRC Section
R807
Appliance located In an enclosure M which all combustion air is taken from the outdoors and the enclosure is equipped
with a solid weather- stripped door and set - dosing device.
IRC M 1701.4
Two openings or ducts. Combustion air shall be supplied through openings or ducts...conrected directly to the outdoors,
such as ventilated crawl spaces or ventilated attics.
IRC M 1703.2
Elevation of Ignition source. Equipment and appliances having an Ignition source and located in hazardous locations
and public garages, private garages shag be elevated such that the source of Ignition is not less than 18 inches above the
floor surface on which the equipment or appliance rest. For the purpose of this section, rooms or spaces that are not part
of the living space of a dwelling unit and that communicate directly with a private garage through openings shall be
considered to be part of the private garage.
IMC 304.3
CLOTHES DRYER EXHAUST
14
Duct penetrations; Ducts that exhaust clothes dryers shall not penetrate or be located with in any fire blocking,
draftstopping or any wall, floor/ceiling or other assembly required by this code to be lire- resistance rated, unless such duct
is constructed of galvanized steel or aluminum of the t Ic kness specified In the mechanical provisions of this code and the
fire- resistance rating Is maintained in accordance with this code.
IRC G2439.2
(614.12)
Exhaust Installation. Dryer exhaust ducts for clothes dryers shall terminate on the outside of the building and shall be
equipped with a backdrat damper. Screens shah not be installed at the duct termination. Duct shall not be connected or
installed with sheet metal screws or other fasteners that will obstruct the lbw. Clothes dryer exhaust duct shall not be
connected to a vent connector, vent or chimney. Clothes dryer exhaust ducts shah not extend Into or through ducts or
plenums.
IRC 02439.3
(614.4)
Make up air. Installations exhausting more than 200 cfm shall be provided with makeup air.
IRC 02439.4
(614.6)
Page3 of 6
Printed 05/26/2008
Fame DCD A10D
14
Clothes dryer ducts. Exhaust ducts for domestic clothes dryers shall be constructed of metal and shall have a smooth
interior finish. The exhaust duct shall be a minimum nominal size of 4 sidles In diameter. The male end of the duct at
overlapped duct joints shall extend in the direction of air flow. Clothes dryer transition ducts used to connect the appliance
to the exhaust duct system shall be metal and limited to a single length not to exceed 8 feet in length and shall be listed
and labeled for the application. Transition ducts shall not be concealed within construction.
IRC G2439.5
(614.8)
Maximum length. The maximum length of the clothes dryer exhaust duct shall not exceed 25 feet from the dryer location
to the outlet termination. The maximum length of the duct shall be reduced 2 -1/2 feet for each 45 degree bend and 5 feet
for each 90 degree bend.
Where make and model of the clothes dryer to be Installed Is known ...maximum duct length shall be permitted to be in
accordance with the dryer manufacture's Installation instructions.
IRC G2439.5.1
(614.6.1)
EXCEPTION
ACCESS OPENINGS (Attics & Crawlspaces)
15
Crawispace minimum access openings through floors shall be 18 inches by 24 inches and 18 Inches by 24 inches
through a perimeter wall. Access doors shall be weather - shipped. NOTE: Access openings shall be sized to allow
installation or removal of any mechanical equipment.
IRC R408.3
Attic space access opening shall not be less than 22 inches by 30 Indies and provide a minimum unobstructed
headroom in the attic access no less than 30 inches.
IRC Section R807
Appliances In attics. Attics containing appliances requiring access shall be provided with an opening and a dear and
unobstructed passageway large enough to allow removal of the largest appliance, but not less than 30 inches high and 22
Inches wide and not more than 20 feet in length when measured along the centerline of the passageway from the opening
to the appliance. The passageway shall have continuous solid f ooring...not less than 24 inches wide. A level service
space 30 Inches deep by 30 inches where access Is required.
M1305.1.3
Appliances under floors. Underfloor spaces containing appliances requiring access shall be provided with an
unobstructed passageway large enough to remove the largest appliance, but not less than 30 Inches high and 22 Inches
wide, nor more than 20 feet in length when measured along the centerline of the passageway from the opening to the
appliance. a level service space at least 30 Inches deep and 30 inches wide shall be present at the front or service side of
the appliance. (see code for additional information)
M1305.1.4
WEATHER PROOFING
16
Weather - resistant sheathing paper. Asphalt- saturated felt free from holes and breaks, weighing not less than 14 pounds
per 100 square feet and complying with ASTM D 228 or other approved weather- resistant materials shall be applied over
studs of sheathing of all exterior wall as required by Table R703.4. Such felt or material shall be applied horizontally, with
the upper layer lapped over the lower layer not less than 2 Inches. Where vertical joints occur, felt shall be lapped not less
than 8 Inches.
MC R71
_1
Flashing. Approved corrosion- resistant flashing shall be provided in the exterior wall envelope in such a manner as to
prevent entry of water Into the wall cavity or penetration of water to the building structural framing components. The
flashing shall extent do the surface of the exterior wall finish and shall be Installed to prevent water from reentering the
exterior wall envelope.
IRC R703.8
Concrete and Masonry Foundations Dampprooflng. Foundation walls that retain earth and enclose habitable or usable
spaces located below grade shall be dampproofed from the top of the footing to the finished grade. Masonry wall shall
have not less than 3/8 Inch Portland cement paging applied to the exterior of the wall. That parsing shall be dampproofed
with a bituminous coaling, 3 pounds per square yard of acrylic modified cement, 1/8 Inch coat of surface - bonding mortar
complying with ASTM C 887 or any material permitted for waterproofing. Waterproofing shall be applied to the exterior of
the wall.
IRC R406.1
(For additional code infomwton see Section R 406 of the 2003 IRC)
SAFETY GLAZING
1 1
Hazardous locations. The following shall be considered specific hazard locations for the purposes of glazing:
(abbreviated) Glazing in:
]B] R308.4
(DCD H014)
1) swinging doors except jalousies,
2) fixed and sliding panels of sliding door assemblies and panels in sliding and bi-fold closet door assemblies,
3) storm doors,
4) all unframed swinging doors,
6) doors and enclosures for hot tubs, whirlpools, saunas, steam rooms, bathtubs and showers, any part of a building wall
enclosing these compartments where the bottom exposed edge of the glazing Is less than 80 inches measured vertically
above any standing or walking surface.
6) an Indvidual fixed or operable panel adjacent to a door where the nearest vertical edge is within a 24 -inch arc of the
door in a dosed position and whose bottom edge is less than 80 Inches above the floor or walking surface.
7) in an Individual fixed or operable panel, other than those locations descibed in Items 5 and 6 above, that meets all of
the following conditions: 7:1 exposed area of an individual pane greater that 9 square feet, 72 bottom edges less than 18
inches above the floor, 7:3 top edge greater than 36 inches above the floor, 7:4 one or more walking surfaces within 36
inches horizontally of the glazing.
8) all glazing in railings regardless of an area or height above a walking surface. included are structural baluster panels
and nonstructural In -fill panels.
9) wall and fences enclosing Indoor and outdoor swimming pools, hot tubs and spas where the bottom edge of the glazing
is less than 80 inches above a walking surface and within 60 inches horizontally of the waters edge. This shall apply to
single glazing in all panels in multiple glazing.
Printed 05/25/2008
Page 4 of 5
Farm f OCD MOO
17
10) adjacent to stairways, landings and ramps within 36 Inches horizontally of a walking surface when the exposed surface
of the glass Is less than 80 Inches above the plane of the adjacent walking surface.
11) adjacent to stairways within 60 Inches horizontally of the bottom tread of a stairway In any direction when the exposed
surface of the glass is less than 80 inches above the nose of the tread.
Skylight and sloped glazing. Glass or other transparent of translucent glazing material Installed at a slope of more than
16 degrees from vertical.
R 308.6.1
Permitted materials. 1) laminated glass with a minimum 0. 015 -Inch polyvinyl butyral kdedayer for glass panels 18 square
feet or less in area located such that the highest point of the glass Is not more than 12 feet above a walking surface or
other accessible area; for higher or larger sizes , the minimum Interlayer thickness shall be 0.030 inch. 2) Fully tempered
glass. 3) Heat- strengthened glass. 4) WIred glass. 6) Approved rigid plastics.
11 308.6.2
For further glazing code requirements, check with the local building inspector.
GARAGES AND CARPORTS
1 8
Opening protection. Openings from private garage directly Into a room used for sleeping purposes shall not be permitted.
Other openings between the garage and residence shall be equipped with solid wood doors not less than 1-3/8 Inches In
thickness, solid or honeycomb core steel doors not less that 1-3/8 Inches Mick, or 20- minute lire-rated doors.
R309.1
Duct penetration. Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage
shall be constructed with a minimum No. 26 gage sheet steel or other approved material and shall have no openings Into
the garage.
11309.1.1
Separation required. The garage shall be separated from the residence and its attic area by not less than 1/2 inch
gypsum board applied to the garage side. Garages beneath habitable rooms shall be separated from all habitable rooms
above by not less than 518 Inches Type X gypsum board or equivalent. Where the separation Is a floor- ceiling assembly,
the structure supporting the separation shall also be protected by not less than 1/2 Inches gypsum board or equivalent.
11309.2
Floor surface. Garage floor surfaces shall be of approved noncombustible material. The area of floor used for parking of
automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
entry doorway.
8309.3
Carports. Carports shall be open on at least two sides. Carport floor surfaces shall be of approved noncombustible
material. Carports not open on at least two sides shall be considered a garage and shall comply with the provisions of this
sections for garages. Exception: Asphalt surfaces shall be permitted at ground level In carports and sloped to facilitate the
movement of liquids to a drain or toward the main vehicle entry doorway.
83094
LIGHT, VENTILATION AND HEATING (Section 11303)
19
Habitable rooms. All habitable rooms shall be provided with aggregate glazing area of not less than 8 percent of the floor
area of such rooms. Natural ventilation shall be through windows, doors, louvers or other approved openings to the
outdoor air Openings shall be provided with ready access or shall other wise be readily controllable by the building
occupants and minimum open able areas to the outdoors shall be 4 percent of the floor area being ventilated.
I
11303'1
Exception: 1) Glazed areas need not be open able with approved mechanical ventilation's system...providing 15 cubic
feet per minute air exchange. 2) Glazed areas need not be provided in rooms where Exception 1 above is satisfied and
artificial light provides an average 8 foot candle over area of the room at height of 30 inches above the floor level.
Mechanical Ventilation. Kitchens- ventilation rate 100 din Intermittent or 25 dm continuous.
Source Specific Ventilation: Source specific exhaust ventilation Is required In each kitchen, bathroom, water closet,
laundry room, Indoor swimming pool, spa, and other rooms where excess water vapor or cooking odor is produced.
1RC M 1606.3
WSVtAC 302.2.1
USEFUL INFORMATION
20
Whirlpool baths shall have a removable panel for sufficient size to access the panp.
UPC 416.1
Pipe Sleeves shall be provided to protect all piping through concrete and masonry walls.
UPC 313.10.1
Ts grade away from foundation walls shall fall a minimum of Oa within the firsts 10 feet.
IRC R401.3
Fuel burning appliances require outside combustion air If placed in garage that are classified as unusually tight.
IMC Section 702
Premises Identification. Approved numbers or address shall be provided for all new buildings In such a position as to be
plainly visible and legible from the street or road fronting the property.
IRC R321.1
21
Crawl space clearance Minimum height shall be 18 inches clearance to the bottom of wood floor joist or a minimum ofl2
Inches to wood girders (breams).
IRC R 319.1 ill.
Moisture barrier. Polyethylene sheeting of minimum 6-mll thickness shall be placed over the granular base. Joints shall
be lapped 6 inches and left unsealed. The polyethylene membrane shall be placed over the pressure preservatively
treated - wood sleepers and shall not extend beneath the footing plates of the exterior walls.
IRC 11504.2.2
Removal of debris. The under -floor space shall be cleaned of all vegetation and organic material. All wood forms used for
placing concrete shall be removed before a building Is occupied or used for any purpose. All construction materials shall
be removed before • building Is occupied or used for any purpose.
IRC 11408.4
22
Insulation for Attics and Vaulted Ceilings. At least 1.5 Inches between the tip of the bats and the underside of the roof
sheathing Is left changes for ventilation in each cavity to allow a ventilation rate of 3.0 air anges per hour. Provide insulation
baffles or taper Insulation to allow for the required air changes.
For vaulted ceilings, provide ridge vent or vent to a gable end to allow continous air flow.
2004 WSEC
Section 1007
a
IV
Page 5 of 5
Printed 05/26/200e
Fvm#DCDA100
By
P2GEC- �11UN�lJE 739o�Gloz3 S' - /
GSA-- �LvC�iStaF
C City of Tu to
ING DA WN
- 2 T1a7hi � boa �uw-_.
4alP v��11V 'X_
...............
_�/10._E / -af - %• S! T� I�L/d�.- . SCn�E --
7 FOC/Nd N77111 I'SIMrN W&Z &W& FGA pLr�aJ
_BW S_ P . 7 AIP_ z7W. Z4Vl TloN
Pee -oF• 7 SOU77� ZLEV,0T0J
5t- cTna,0 71P /4-1
F E pERA�1IT
ED FO1t: MedMkal
g s ins
City of Tukwila
BUILDING DIVISION
lil I JI III Ill -.I I1I: ICI I ICI, I�LT�1 iji {jl l ill I I III ►{I I { "1 l 1 �11;�
I. I I I I ..1I ql 1 I I I 2I iti
5:: I 61
Inch 1N8.. —vl a e i tga.t S, E
&A
/�/�� � � t Y n •tiu'v ua er ^r•.ct �-x .. xtc t a e r .
S1nc� a 8p *..
9I6 f 0 �6 ..�. ����• � B f iiUlniinnilullnllnliLllllil llIIIIIII.� IiiiinliilJOT llhiliili�lilllilll�lililiiii�iii {liiii�iiuliiii�iiiiliii.{�_
Of work
TUkWila Bulldl
NOTE: ReAftm will requi
and may indude add►w,
37 TN
37�N hUf•S i
ads to the
f
Dr approval of
1 Dhdslon.
a new plan
I plan review fi1mL
vj O'MPPIIANCF-
CODE
00,00evocO --
mm 3 0 2006
—' �� gffiUkWild
�UtL�1iNP IITUTSIQ��
RECEIVED
CITY OFTUKWILA
APR 19 2006
PERMIT CENTER
slow l3°1
i7fY�7t�__ 3 7TH
wMT�f -3s .�
P%�2CFl. _.NUh�l.�3,+� ?34d60r1�23 l Ca o,
i
_. �
SCJ"D�C,� qL8" w / /Z`'DiK
, 1
�EX.I S T /;il6- Z'i?t�i27"�STf—
- - �'O/►JC' i SfI�,(3 Orrl -��i�0�' _7`T -_ �jL-
i;
;%
loll
Ct 1 O �..
/8 -'`A .
M
G�oonNb p�giN b1
5 �ti
,i�i3s �r .�voF
- ILIIIIIIIIiILI�1IIII !IiIIIIII~�Ii2IIIi��i��L14��,I
Inch 1/18 a.W.
Tq
... S /nCE 187 r xt' f un,rjr?
5IL ti6..
L*04
Z6':x L6 ?rsr�
E t'r IIS�r �8 i
IIU "IIIIIUIIIIIIIIIiIIL;. Im 1111LIllllllllllll1I1111I1111IIIll 11 ),1111 1111111
TM` iI��TjIiILI !+III►��_1151►�I11�►1►��
�6�
iiii iilililii iilllillli1I1111uIi1illf ►iiliiiiliiiiliiiiliii.11
REVIEWED FOR
CODE COMPLIANCE
�497►+Par°'aCj� _
MAY 3 0 2006
—Q I ty I PH 2�
RECEIVED
CITY OF,TUKWILA
APR 18-2006
PERMITCENTER
- 2 06.._ -�W
0
I
REGE VED
7.9o47- 3' 4? 01 C CITY OF LA
TOKWI
6.
/4 nz 3 :,3 ,`A_1t1 APR 19 2006
.zx6 PT sip 0z
P
ERMITCENTER
L
NZ
D
.
I.: I ,I
�.� Y .v
U
P 0
N 0 p
A (0)
p,
Cr U
C111(_
2
C IDIIS711,15
Stir CfXrSTJ±/6_ -q.
j
mcg
og
4 Oq e 0
3 00 ezr17-4
CONCRETE FOUNDATION WALL JOIN
(4) 1/2"x 18" all-thread or #4 R. B., Epoxy hardware
4" embedded into existing foundation, two into
existing foundation wall and two into footing. Clean
holes prior to inspection.
Call for inspection prior to applying epoxy.
MEN NUNN
kll)va
Jd�
30' 3
9
:D OR
RMEANE
N-1v A)
BODE COMPS
14 A
7 7--
rate Fv �Of tu
A A
-w 3! x Uri-
C6 .11 11T611
21 i'i
IAIMMi
M's
Ao ESK
Md 4 M141101
-g
9
v
w
I
i
RECEIVED
CITY OF TUKWRA
APR .18 2005
PERMITCENTER
4
ili rli iIi iIi iiitili III iIi ►11.111f�tllll, rj►�
1 i 51'��II�I�I��� s
Inch Te
2.,
�11 `rv51s4
. . '1CV 1 1 �. t � • �r +.r*+.wrkw�e�r�t� �.r �x v^�nc.,�.te: r^ y �. ._ � � .
Sinu1e72+° yU1 1
M'`OaIS, 8s�+s you q b E Z l `: woI
LL ii hi i�i li I ilii. I ii:ilii I ilii liii ( 1J
iiiili :Iii 'iiililii liiiliiii iililii�i iiiilii`�ii iiiilii "i iiiil►iii iiiiliiii iiiiliiii iiiiliii.i _ � `` � �
Ism 01\1
r
I-
C E/L /N,;, L /iV E' _
Inch 1116 r
� 4Sl.i'i Y
£3TCOTT®
since 18; 40
�i�ai I � (�Ii.��r ►;rll r�� > >T► i � � � i � �t� -!5�� �� �����1 ��' � 6
qq 3s a'�i 1..K'"f�YP c JTVn ?t'
aka tS �.
".aclo -
3o10
�111III
��o-�L��Wi1a`
�P��� \Ifi
MINI
a
` R VIEWED F� �E
�--- � CODE�pMPLI .
OfT�kWi1a �
N 10
SoUT6f �L Vj
•ili i�'r iIi ili ili�i�i iii ili ilr iii i�it �I� i � ill 11 ►Ii iii ilili�> >�� ��i-� �� , � I ,
Inch 'rc�
{
dr
i _....„2.x'6... de ,U6 'Toel L°.... /1 ' —
�' 12- 3e GA INS41,4,4r1,9N
0
• i(JFh/ fi�uNUfIT/cW ---- �:RGbF__�Tti.:�W/fZL•_. -. S/� /�V6 '
D 7doo -=;6A Zx 12
LuS.z� o
ZX6 LP�Q
t It oGCQ
E 2 a /
Ato
l 1 .
iil1itiTi1ilii1 I iiiiili%iiji -►2 iiih�h iii I i�►�i (illy . , ��lil►�►ti�it51� ���I 6
Inch r4,t4�
Gv r c.•y *•^rt s s x'.nr 51,.x
Slnee1872"
l Nol
V
•' n �nilini niiliui iiuliiu �iiiliiii niiliih uilli.i:� �Inliiii Iiiiliiii iirlliiii iiiiliiii iiiiliiii iiilliiii iii�illiii iiiiliiii iiiiiii.i
RECEIVED
CITY OFTUKWILA
APR 1.8 2006
PERMITCENTER
dGr:�us/yT
%.?7. ;QA�r iivsvl.� r/aN
?1G. �bf8 561�:s %q %tiG1_Q4 /ld /.t16 G✓/I�9P
REVIEOWp�A ��
CODE C
MAY 3 0 X006
,Mp f)IN11olm
TYPICAL rP0Me k Jr7,ry W iV,9 L
i
I
O y
-4
Room
3- 2- (- 5-4,
Ad e
NEE
fwk ICT
� e— --e .- .7
-row
10-6
o _.6
RECEIVED
---------- 34L 0 CITY OF TUKWILA
INCOMPLETE -ell MAY 2.4 2006
L
TR# PERMITCENTER
oj iv
4'�
nch 11 16
ap.,
Since
I I Hill 11111111111111111
I Ill I'llifililill'i HIM I
11 -01 -2006
ANA PULOKA
13350 37 AV S
TUKWILA WA 98168
RE: Permit No. 006 -139
13350 37 AV S TUKW
Dear Permit Holder:
In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division.
Per the International Building Code and/or the International Mechanical Code, every permit issued by the Building Division under the
provisions of this code shall expire by limitation and become null and void if the building or work authorized by such permit is not
commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended or
abandoned at any time after the work is commenced for a period of 180 days.
Based on the above, you are hereby advised to:
Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or final inspection.
This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if
the project should be considered abandoned.
If such determination is made, the Building Code does allow the Building Official to approve one or more extensions of time for
additional periods not exceeding 90 days each. Extension requests must be in writing and provide satisfactory reasons why
circumstances beyond the applicants control have prevented action from being taken.
In the event you do not call for the above inspection and receive an extension prior to 12/02/2006, your permit will become null and
void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
�nw
J � a t f erLta hall,
Permit Technician
MPoR
xc: Permit File No. D06 -139
City of I ukvvila Steven M. Mullet, Mayor
Department of Community Development Steve Lancaster, Director
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665
April 21,2006
Ana Puloka
13350 37 Av S
Tukwila WA 98168
RE: Letter of Incomplete Application # 1
Development Permit Application D06 -139
Makaafi Residence —13350 37 Av S
Dear Ms. Puloka:
This letter is to inform you that your application received at the City of Tukwila Permit Center on April 18, 2006 is
determined to be incomplete. Before your application can continue the plan review process the attached items from the
following department(s) needs to be addressed:
Buildine Department: Mien Johannessen, at 206 433 -7163, if you have any questions concerning the attached
comments.
Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other
documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be
resubmitted with the appropriate revision block.
In order to better expedite your resubnnttal a `Revision Submittal Sheet' must accompany every resubmittal. I have
enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by
a messenger service.
If you have any questions, please contact me at the Permit Center at (206) 433 -7165.
Sincerely,
rshall Jll rr ✓J
2 Techni
Enclosures
File: Permit D06 -139
City of Tukwila
Department of Community Development Steve Lancaster, Director
P:VenniferVncomplete Letters V00611)06-139 Incomplete Ltr #1.DOC
jem
Steven M. Mullet, Mayor
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 -431 -3670 • Fax: 206 -431 -3665
Determination of Completeness Memo
Date: April 20, 2006
Project Name: Makaafi Residence
Permit #: 006 -139
Plan Review: Allen Johannessen, Plans Examiner
Tukwila Building Division
Allen Johannessen, Plan Examiner
A Building Division has deemed the subject permit application incomplete. To assist the applicant in
expediting the Department plan review process, please forward the following comments.
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same
size)
1 Provide a floor plan for each level of the existing house. The floor plan shall identify with dimensions all
exterior openings.
2 Label all rooms of the existing house including the new rooms.
Should there be questions concerning the above requirements, contact the Building Division at 206 -431 -3670.
No further comments at this time.
ACTIVITY NUMBER: D06 -139 DATE: 05 -24 -06
PROJECT NAME: MAKAAFI RESIDENCE
SITE ADDRESS: 13350 37 AV S
Original Plan Submittal
Response to Correction Letter #
X Response to Incomplete Letter # 1
Revision # After Permit Issued
DEP RTMENTS:
Bui Ir Divisi
Public Works ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
Approved ❑
Notation:
Documents/routing slip.doc
2 -28-02
APPROVALS OR CORRECTIONS:
REVIEWER'S INITIALS:
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
Fire Prevention
Structural
Incomplete ❑
Approved with Conditions
DUE DATE: 0
DATE:
DATE:
Al io
Planning Division Cgr
Permit Coordinator
Not Applicable
No further Review Required
DUE DATE: 06-22-06
Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
ACTIVITY NUMBER: D06 -139
PROJECT NAME: MAKAAFI RESIDENCE
SITE ADDRESS: 13350 37 AV S
DATE: 04 -18 -06
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
DEPARTMENTS:
k - 22 - O(a
131. ng ivfsion
Public Works IA Structural
L�IM lt1I_ 4- -2o-0c.
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: OI1 I,, 1
� Id/ LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials
TUES/THURS ROUTING:
Please Route ❑ Structural Review Required
REVIEWER'S INITIALS:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Documents/routing slip.doc
2 -2802
> PERMIT COORD COP\'e
PLAN REVIEW /ROUTING SLIP
l; l 4 Zo
Fire Prevention
Incomplete
Planning Division
❑ Permit Coordinator
DATE:
DATE:
Not Applicable
No further Review Required
DUE DATE: 04-20-06
DUE DATE: 05-18-06
Approved with Conditions ❑ Not Approved (attach comments) ❑
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Date:
f/0
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.cr.tukwila.wa.us
Steven Al. Mullet, Mayor
Steve Lancaster, Director
I
REVISION SUBMITTAL
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Plan Check/Permit Number: D06 -139
® Response to Incomplete Letter # /
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Project Name: Makaafi Residence
CITY KWILA
MAY 2 4 2006
PERMIT CENTER
Project Address: 13350 37 Av S
Contact Person: /kt , R /o% Phone Number: O70 G - X76 - f'3 SSd
Summary of Revision: �/
1�17lr l .v F /n.0_ Plat -AS u FX 1ry /er )177C aS Y'Pnrec4-
'l' Stt4rtr /We 6'35 4 4. -
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by t i I l 02/41
, Entered in Permits Plus on CS -t I (XD
\applicationsVomu- applications on line\revision submittal
Created: 8-13 -2004
Revised:
x
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
STATE OF WASHINGTON)
COUNTY OF KING
SS.
AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION
T ! (/ .5' 7 eft Haig % /l 4 4114 ' `t c 04 states as follows:
[please print]
Permit Center /Building Division:
206-431 -3670
Public Works Department:
206 - 433 -0179
Planning Division:
206 - 431 -3670
PERMIT NO.: G — 73
1. I have made application for a building permit from the City of Tukwila, Washington.
2. I understand that state law requires that all building construction contractors be registered with the State of
Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of
Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW
18.27.090.
3. I understand that prior to issuance of a building permit for work which is to be done by any contractor, the City of
Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions
stated under RCW 18.27.090 applies.
4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that
after reading the exemptions from the registration reqpirement of RCW 18.27.090, I consider the work authorized '5 under this building permit to be exempt under No. l , and will therefore not be performed by a registered
contractor.
I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an
unregistered contractor to perform construction work.
A . .......... Cer-
o� i.
• ;U
r•a
yN t; PUBLG 1 2 2
4 h 9 T + e .18. Qs • • : it
\applications\B -2004 affidavit in lieu of contractor registration
APPLICANT
Signed and sworn to before me this
5th day of May
ob.;9. (L 10 r
NOTARY PUBLIC in and for th! State of Washington,
Residing at King
Name as commissioned:
My commission expires:
2006 .
, County.
Alice, A. Deacy
6-16-08
18 27 090 Exemptions. This chapter shall not apply to:
1.
2. An authorized representative of the United States
Government, the State of Washington, or any
incorporated city, town, county,. township,
irrigation district, reclamation district or other
municipal or political corporation or subdivision of
this state;
3. Officers of the court when they are acting within
the scope of their office;
4. Public utilities operating under the regulations of
the utilities and transportation commission in
construction, maintenance, or development work
incidental to their own business;
5. Any construction, repair or operation incidental to
the discovering or producing of petroleum or gas,
or the drilling, testing, abandoning, or other
operation of any petroleum or gas well or any
surface or underground mine or mineral deposit
when performed by an owner or lessee;
6. The sale or installation of any finished products,
materials, or articles of merchandise which are not
actually fabricated into and do not become a
permanent fixed part of the structure;
7. Any construction, alteration, improvement or
repair of personal property, except this chapter
shall apply to all mobile, manufactured housing. A
mobile/manufactured home may be installed, set
up, or repaired by the registered or legal owner,
by a contractor licensed under this chapter, or by
a mobile/manufactured home retail dealer or
manufacturer licensed under chapter 46.70 RCW;
8. My construction, alteration, improvement, or
repair carried on within the limits and boundaries
of any site or reservation under the legal
jurisdiction of the federal government;
9. My person who only furnished materials,
supplies, or equipment without fabricating them
into, or consuming them in the performance of, the
work of the contractor,
10. My work or operation on one undertaking or
project by one or more contractors, the aggregate
contract price of which for labor and materials and
all other items is less than $500.00, such work, or
operations being considered as of a casual, minor,
or inconsequential nature. The exemption
prescribed in this subsection does not apply in all
instance wherein the work or construction is only a
part of a larger or major operation, whether
undertaken by the same or a different contractor,
or in which a division of the operation is made into
tapplications -2004 affidavit in lieu of contractor registration
contracts of amounts less than $500.00 for the
purpose of the evasion of this chapter or
otherwise. The exemption prescribed in this
subsection does not apply to a person who
advertises or puts out any sign or card or other
device which might indicate to the public that he is
a contractor, or that he is qualified to engage in
the business of contractor,
11. Any construction or operation incidental to the
construction and repair of irrigation and drainage
ditches of regularly constituted irrigation districts
or reclamation districts; or to farming, dairying,
agriculture, viticulture, horticulture, or stock or
poultry raising; or to clearing or other work upon
land in rural districts for fire prevention purposes;
except then any of the above work is performed
by a registered contractor;
12. An owner who contracts for a project with a
registered owner;
13. Any person working on his own property, whether
occupied by him or not, and any person working
on his residence, whether owned by him or not but
his exemption shall not apply to any person
otherwise covered by this chapter who constructs
an improvement on his own property with the
intention and for the purpose of selling the
improved property;
14. Owners of commercial properties who use their
own employees to do maintenance, repair, and
alteration work in or upon their own properties;
15. A licensed architect or civil or professional
engineer acting solely in his professional capacity,
an electrician licensed under the laws of the state
of Washington, or a plumber licensed under the
laws of the state of Washington while operating
within the boundaries of such political subdivision.
The exemption provided in this subsection is
applicable only when the licensee is operating
within the scope of his license;
16. Any person who engages in the activities herein
regulated as an employee of a registered
contractor with wages as his sole compensation;
17. Contractd&s,`•4n• highway projects who have been
prequalified 'at required by chapter 13 of the Laws
of 1961, RCW 47.28.070 with the department of
transportation tr perform highway construction,
reconstruction, bf- Maintenance work.