Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0197 - WESTFIELD SOUTHCENTER MALL - CRAZY 8
CRAZY 8 1036 SOUTHCENTER MALL ELO8-1 97 Citylkf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1036 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -197 Issue Date: 05/12/2008 Permit Expires On: 11/08/2008 Tenant: Name: CRAZY 8 Address: 1036 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: SARAH NEILSEN Phone: 800 - 541 -0821 Address: 1120E 80TH ST SUITE 211 , BLOOMINGTON MN Contractor: Name: SIGN -TECH ELECTRIC LLC Address: 5113 PACIFIC HWY E, SUITE 12 , Contractor License No: SIGNTEL988BG Phone: 253 - 922 -2146 Expiration Date: 01/07/2010 DESCRIPTION OF WORK: NEW RECEPTACLES, SWITCHES AND LIGHTING Value of Electrical: $28,000.00 Fees Collected: $676.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: 1` I hereby certify that I have read and ex this work will be complied wi Date: cs(izJsb Led this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the ance • • ork. I am authorized to sign and obtain this electrical permit. ' Signature: .' Date: �� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -197 Printed: 05 -12 -2008 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 1036 SOUTHCENTER MALL TUKW Suite No: Tenant: CRAZY 8 Permit Number: EL08 -197 Status: ISSUED Applied Date: 02/28/2008 Issue Date: 05/12/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date:' ---;r5 £ Print Name: Z'� i� /J / /-72,/-27.c.zSG1)---) doc: Cond -Elec EL08 -197 Printed: 05-12 -2008 CITY OF TUKWIL", Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwilawa.us Electrical Permit No. E 8! 1 7 Project No. PV t 6I (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 1 e ecg\ €cr MCLV. King Co Assessor's Tax No.: (03Cc4 -2b ' OCI1 O Tenant Name: Cr-al-LA Property Owners Name: VVp ° -fi e_Xd ent-pc.-c-c c)Y1 Mailing Address: 112.0 ECt c l cam^ k-c • c-iw,-ke Z.\\, Bo p v Yqtotr\, Mk) SS4 ZO City State Zip Suite Number: (2.ZC) Floor: New Tenant: ® Yes ❑..No CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: cgAxcOrx N t eXSe -Y1 Day Telephone: SOO 1S41 - Og21 Mailing Address: 112-0 EIS g O t - 1 f 1 SW-eel- - ..A.,.....--4-e Ztt, g\O w1\r 1 tbrlt t ' 4 S 4Z0 City Stale Zip E -Mail Address: "&Q1C -taYl@ eAdpc- oNneS • GOPYt Fax Number: 9'S2- I gSt•1--W9 09 ELECTRICAL CONTRACTOR INFORMATION Company Name: T• B• D . Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: State Zip Valuation of Project (contractor's bid price): $ 2. COO Scope of Work (please provide detailed information): Neu) CP—C.P cat° S SC.0 \'FC�IP S ILA klk ►r9 Will service be altered? ❑ Yes IN No Adding more than 50 amps? ❑ Yes "', No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel IN Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light 11: \Applications\Fnrms- Applications On Line' -2007 - Electrical Permit Application.doc bh Page 1of2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75M0 ea ❑ Low voltage systems (alarm, furnace thermostat) 555.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 575.00 (no added /altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits 510.00 ca ❑ Circuits added /altered without service change 550.00 (up to 5 circuits) ❑ Circuits added /altered without service change 550.00 (6 or more circuits) S7.00 ea ❑ Meter /mast repair 565.00 ❑ Low voltage systems 555.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals 575.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: "` " ` t ', Nl� Date: 2 /zs /o g Print Name: 41/41k $0ii t�'t l Day Telephone: ( gar c4t ogz Mailing Address: 2 U4-14 mod- Z (.1 � �O� P vw City State Zip Date Application Accepted: —•)__E _Or Date Application Expires: 9 Staff Initials: H.'\Applicabons \Forms- Applications ()n Line'A -2007 - Electrical Permit Application.dec bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -197 Address: 1036 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 02/28/2008 Applicant: CRAZY 8 Issue Date: Receipt No.: R08 -00562 Payment Amount: $135.30 Initials: WER Payment Date: 02/28/2008 12:04 PM User ID: 1655 Balance: $541.20 Payee: ELDER -JONES TRANSACTION LIST: Type Method Description Amount Payment Check 50933 135.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 135.30 Total: $135.30 9201. 02/28 �71O TO T& 1405.85 a�� doc: Receipt-06 Printed: 02 -28 -2008 INSPECTION RECORD Retain a copy with permit 60Y- R1 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION r4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti Project: 1 frvi I Type of Inspection: 2/00 Address: /536 11414, Date Called: .."----% Special Instructions: A Date Wanted: rn a:m: Requester: Phone No: X Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 04 - Inspector: 6tk, Date: 07 tab A ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project: y Type of Inspection: polo Address: /v JNP V �� Date Called: '71.1: � Special Instructions: I� ° 11`'ZA tOX ' IA LA Date Wanted: T O7 / p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: _ AlV jtec -11G L cce.AW1 FtaE. S 10 Mk. OPN &ojx4L ( -(4 . w ,Iµ uJe4P ,ksr - 5 ZJFl5 - red Al k 5 14 FQodr C i u�it� AccCS5 - Cote 44 2- £4-51 Eat-P. viottOntil • S (cv C Cotm44 2 LA1f5-r c P. - oIA) Ott, 1J CA4 ponikikki Atai Ckwietp roc, Wet., 14V - d-►/ P kL- Dletabel ' ►cc) e.A !- a fct RE 'e9 Fo& fA1STh for - osit io& Fk c pi5eccTtbAdrit t. Inspector: grAileg, Date: 07/0.7/b,8 $60.00 REINS I ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: •• wite.euer. y,Ae4XYF etstear ll.rrLw- _ a'tll.ff� Ife:ifir-/97 f INSPECTION RECORD (/> Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36j0 Project: 9A: Type of Inspection: N. LS c T 4T 1) G U/X Pa a l .J LL ess- /pedal L' /?//91 G Date Called: r.,/,) —"wk. ' /1674 ---// L,G�M,y � pecial Instructions: 67,1*-47(. AP w 7 -61 7 iti/ /. • /%/17 q Date Wanted: n �i► I r 7 la p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: bq \ a — (V1</h L it 1/1)6' :- L1 /W/:71 LS c T 4T 1) G U/X Pa a l .J LL ON Al T - 46 <f :- $ r.,/,) —"wk. ' /1674 ---// L,G�M,y 6 2 /f/% ? 4, I e TO AI czIlitil� 7- 9/}ilc C/"6 / . {4,./e 67,1*-47(. AP w 7 -61 7 iti/ /. • /%/17 q Insp /GC /,7w4,j'.q/('i Date44,47/ai„, El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: eS rffieke 4112-vtr.. }r •Gn...sc .: . • _ +c _._ __ -.At. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 0- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Iftos-f? Pro ec �.. Type of Inspection: Address Alt/Date Called: penal Instructions. Date Wanted: Zozitiv a •m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. OMMENTS)0 (ef Il44/((_ c. i4, S LAS /-) /',4 — Maur 612G -T704) 94) rj'Vth/4f V445 Insp Date:i f6 4 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit f INSP CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti Project: co Y Type of Inspection: 7 s Address: snafh Z11 Ait, Date Called: 5/O3G Special Instructions: Date Wanted: (/ / p.m. Requester: Phone No: 0 Approved per applicable codes. Skorrections required prior to approval. COMMENTS: fit cT/ /✓; 6 c 4/ C ‘‘)/T1.--/ /A) /d' il of tL //X 714(J.< ns ector� Date: p ��,�� 1/7444 G� 6f //c y J $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: cr INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT O. g. (206)431 -3670 P C ` Type �� �(� Address: AA 11141L- 036 - i�'�'41L. / Date Called: special Instructions: Date Wanted: / / / J' a.m. p.m. Requester: Phone No: roved per applicable codes. Corrections required prior to approval. OMMENTS: //1.. (i/ovic',<4,4e, e7, - /,JST /6&p4 -0/46 1/ANT Ins a r: Date: � /l%se.,. i/St(74044(6/7/ El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit fag-197 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Pr Type of Inspection: Address. Date Called: pedal Instructions: Date Wanted: �� �- a:m Requester: Phone No: roved per applicable codes. Corrections required prior to approval. C s MMENTS: - S,Ei21/ /Gf im-wenic# Date /2 f /O( $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: 1 INSPECTION RECORD C! t Retain a copy with permit 0 "' INSPECTION NO. PERMIT O. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)43 1 -3670 Project: A/9 , Type of Inspection: -7oo3 Address Date Called: Special Instructions: Date Wanted: _ 2-a a.m. P.m. Requester: Phone No: ►1 . pproved per applicable codes. El Corrections required prior to approval. COMMENTS: ,0/1 014--6fAt c 0V4 / --_ -'1'e Jig f4 InspectV jai /rir. //j f /r Date/ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION It- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 6.0— 177 Project: � r s p Type of Inspection: 7010Z/413034 Date Called: - ^1 Address: 2 J � � t� Instructions: Date Wanted: 11Special (d+ p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Dg. - c-A1 mac, ,z.E uJ - o *D &7 Inspector: Ti-ri tirolk& 1Date: os..-1614 El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPEC1bON NO. INSPECTION RECORD Retain a copy with permit 61-01- ITJ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 61' 6 I S e Type of Inspection: 0 D Address: 2-1,1(p s4 A I �L/� Date Called: Special Instructions: Date Wanted: 05 ii!v /� m. (4.m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: ti 6elkiA)64 Dater si % V' 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: e 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary: 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address CRAZY 8 Date 2/25/2008 1036 SOtUTHCENTER MALL For Building Department Use TUKWILA, WA 98188 Applicant Name: G!MBOREE CORP. Applicant Address: Applicant Phone: Project Description 7 New Building —I Addition [ Alteration ❑ Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting Gl Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area SALES SALES FLOOR - 1.50 2399.0 3598.5 SALES MERCHANDISE DISPLAY EXEMPT. TBL 15 -1 FOOTNOTE 10 1.50 2399.0 3598.5 SALES FIXTURE C1 - INCAND. PENDANT ,�+p'��� l,7 ®_ - 60.0 1020.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 7197 .0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES FIXTURE Al - RECESSED COMPACT FLUORESCENT 50 35.0 1750.0 SALES FIXTURE T3 -. 9 45.0 3105.0 SALES FIXTURE C1 - INCAND. PENDANT ,�+p'��� l,7 ®_ - 60.0 1020.0 STOCK 4 FT STRIP FIXTURE r' J'`,,, _-•�R` YNICE _ 31.0 217.0 TOILET FIXTURE F - WALL MOUNT FIXTURE C0U0 , .1, •• 14tC 32.0 32.0 • 200% MAR0 1 4 la Total Proposed Watts may not exceed Total Allow*L \V--': nterior Total Proposed Watts 6124.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical-Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. FILE COPY Ei.bO�' 1 .:t�` :•. F @VEr) • FEB 282008 ;'EFUVI1-r CENTER 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers *Other Qualification Checklist Lighting Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is "Other' and Fixtures: ` fixture answer is checked, the number of (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector fixtures in the space is not limited by Code. 1521) or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- Clearly indicate these spaces on plans. If Cafeterias, fast food establishments', restaurants /bars5 tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. not qualified, do LPA Calculations. 1.1 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 1.0 Retain'', retail banking, mall concourses, wholesale stores (pallet rack shelving) 3. LED lights. TABLE 15 -1 Unit Licthtinci Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retain'', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall'•° 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft2 may be used. 8) Reserved, 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ftZ. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w/ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Ener• Code Com•liance Form Lighting,:; Motor, and' Transformer Permit Plans Checklist' 2006 Washington State Nonresidential Energy Code Compliance Forms -CHK Revised July 2007 Project Address CRAZY 6 Date 2/25/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations vertical glazing Indicate vertical glazing on plans overhead glazing Indicate overhead glazing on plans n.a. 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location n. a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off . Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 (Max. watts 'Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. 1 1511 IElec motor efficiency {MECH -MOT or Equipment Schedule with hp, rpm, efficiency I I I TRANSFORMERS (Section 1540) yes I 1540 (Transformers 'Indicate size and efficiency I I If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energ Code Compliance Form tang, Motor, and ransforrner, Permit Plans C ecklist: `LTG -CH 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all Toads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors. or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). AR I N C O R P O R A T E D S A I N T L O U I S / D A L L A S ARCHITECTURE • ENGINEERING • STORE PLANNING March 25, 2008 City of Tukwila 6300 Southcenter Blvd Tukwila, WA 98188 RE: Crazy 8 Westfield Southcenter Project No. 080078 To Whom It May Concern: This letter is in response to changes to the approved permitted drawings for the above project. If you have any questions, comments or need any additional information regarding this letter please contact Greg Winchester at ArcVision Inc. 800 - 489 -2233. A0.0 Revised landlord contact info. A0.1 Revised ceiling spec for stockroom. Updated ceiling information on responsibility schedule. Revised glass door height on door legend. A2.1 Added wall furring at the rear of sales area for fixture support. Updated partition legend for extent of gypsum board. Revised keyed notes 1, 2, 4A & 29. A3.1 Revised front room of sales area to have gypsum board ceiling. Added landlord notes. A4.1 Revised elevations to indicate gypsum ceiling at front of sales area & revised soffit heights. A5.1 Revised spec for reveal. Revised glass entry door height & show window height. A5.2 Revised spec for reveal. Revised height of glass doors on detail 1. Revised height of glass and soffit on detail 2. A5.3 Revised spec for reveal. Revised location of storefront per lease line on details 1, 3 & 6. Revised glass header detail 2 & door header detail 9. A6.1 Revised threshold spec on detail 5. Added gypsum board ceiling detail 13. 1950 Craig Rd. - Suite 300 • St. Louis, MO 63146 • Phone (314) 415 -2400 • Fax (314) 415 -2300 E1.1 Added power general notes 22 -24 & revised note #21. E2.0 Revised lighting keyed notes 1 & 3. Added emergency light to restroom. E3.0 Revised light Dl on schedule. E4.0 Revised power riser and panel schedule HV. E5.0 Revised lighting spec 16201. M1.0 Added landlord notes. M2.1 Added landlord notes Sincerely, Greg Winchester Project Manager CC: File Arc Vision Inc. 1950 Craig Rd. - Suite 300 • St. Louis, MO 63146 • Phone (314) 415 -2400 • Fax (314) 415 -2300 HERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -197 DATE: 04 -01 -08 PROJECT NAME: CRAZY 8 SITE ADDRESS: 1036 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 BEFORE Permit Issued DEPARTMENTS: B�f1et'ing Dili�i n Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04-03-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUT G: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-01-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 "EMT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -197 DATE: 02 -28 -08 PROJECT NAME: CRAZY 8 SITE ADDRESS: 1036 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: c.3. ui . ing Division Fire Prevention Public Works n Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03 -04-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 04 -01 -08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: SITE ADDRESS: PERMIT NO: • t('71 — 1 '- ORIGINAL ISSUE DATE: J, (, REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 DI''{ - of , d __410/‘1 Summary of Revision: (V U11.li20v CVAAM k\1141--- G-IlAKtir it�4 4 t {a S►bL PO/ l % vilAL i &; j Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Stu/unary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please. print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF ,_ INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 -431 -3665 Web site: http : //wwti',ci.tulavila.wa.us Steve Lancaster, Director REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 04 [ 01 V li Plan Check/Permit Number: E\ pg • 1 a1 ❑ Response to Incomplete Letter # ❑ Response to Correcti n Letter # Revision # ' r Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner RECEIVED crry OF TUKINRA APR 012008 PERMIT CEN TEH Project Name: C o Z. g Project Address: 1 b3 ISo�1thC2r*e r M� -�1 - Space 122p Contact Person: S ■ e\ ser\ Phone Number: 2t6 j1-t - 02.z l Summary of Revision: R9N1i S1 ovS }p \ \c r pp `` Oe - r - c sec-, r p�c1P �che� u \e . CSee a acl ed 1r Sheet Number(s): El 1 E .O, E3.01 EL}- -Ot ES.c "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on \applications \fonns - applications on linc\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electrin or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SIGNTEL988BG Licensee Name SIGN -TECH ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602152490 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 5113 PACIFIC HWY E #12 Address 2 City FIFE County PIERCE State WA Zip 98424 Phone 2539222146 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/7/2002 Expiration Date 1/7/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License MORRIT *943K6 Electrical Administrator Information License MORRIT *943K6 Name MORRISON, TRAVIS Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MENDENHALL, JOHN C PARTNER/MEMBER 01/07/2002 MENDENHALL, LINDA D PARTNER/MEMBER 01/07/2002 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SIGNTEL988BG 05/12/2008 C.3 '411E1111111111 III r■rri■■■■■■rr•rrr ■ rr■rrrr ■rrrrrrrrrrrrr■ ■■■■■■■■■■■■■■■■■■ ■r■rrrrrrrrrrrrr■rrrrrrrrrr5-5- r5- rrr■■rrr■ rrrr' ari rrrrrrr■ rrrrrrrrrrr ■■rrrrrrrrrrrrrrrrrrr■rrrrrrr ■ ■■ ■■ ■ rrrrr ■■ ■■ ■r■■ ■r■■rrr■rr■■rrrr 5-r■ ■rrrr rrrrrrrrr ■■rrr■rrrr■r■rrrr■rrrrr■■ ■ ■■ ■ ■■■■■■■ ■rrrrrrrrrrrrrrrrrrr■ ■rrrrrr■rrr■rrrrrrrrr■rrr■ ■■■■ ■ r■rrrrrr ■rr ■rr■■r■■rrrr ■ ■■ ■■ ■5-r■ rr■■■rrr■EI air rrrr■■ 5-5-5-5-5- ■■rrrrrrrrrrrrrrrrrrrrrrrrr■ ■rrrrrrrrrrr r 5-5-5-5-5- r rrrrrrrrrrrrrrrrrrErrrrrrrrrrrrrrrrrr■ ■■■ rrr■ urrrrrrrrrrrNrrrrrrrrrrrrrrr5-rrr rrrrrrrrrrrrrrrrrr ■■ rrrr■■ 5-r■■ 5-r■■ r■ rrrrrrrrrrrrrrrrrrrrrrrrrrrrrr■ rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr ■5-r■ rrrr■ rrrrrrr■ rrr■■ rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr■■■■■ r■rrrrrrrrrrr■■rrrrrrrrrrrrrrrr ■rrrrrrrrrrr■, 'rrrr !! 5-1% r!!!!!/! !!!!!!!!./!/ / / /./// / /llrr�! /1J" / rr r r / r/ r/ Jrr/ r//!/// /!//// / /1J71.5 /rrrrr. AIM" % / / / /JI/ %/ /% r / / / /1 /�1 10 I 011 111 1 VIA -7/C A -3 a- i_i-i_i-47 -i -� a-i -a r-i-i-A -A -�.� �_i-iii-� m -i.a_a-i-i -i ,�� �_ii_i_i.��.i i �.�fff�7i:i:r�i:i:i:. HV -2/4/6 III �- — !!I �i °.; i %/I % / % / / % / / / % % /%d iiLeA I - L (1 LSAT' ur■ r■ r ,rr■■■rrrr■rrrrrrr■rrr■rr■rrirr rrrrrrri•■r■IIrrrr■ rrr■ rrr■ Irrr r ■rrr■■rrrr■rrrlI•■•UPErrr■r■■r• rrrr■■ ■■r5- MEr5-■rrrrrrr ■r■■■■■■■■■■■•: u5-■■■Urr■■ rrr■■ 5-r■ rrrrr■rrr■rrr■r,IErrrr■rrrrr■■w a5- ■rrrrrr■rrr■rrrrr■rrr■rrrrr■■■ rrrrrrr■ rrrrrrrrrrr■■■■ ■■■■r■■■rrrrrr■■■■rrrr■r5-5-rr5-ii 0 ©1 4:1) A-30 WH -1 VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH —IN. EM EM :: :: ME ME ■■ M: A -34 A -24 1` CONDUIT TO TELEPHONE TERMINAL BD. A- 6,8,12,20 w5- - �- =____ _ ' = __MMMMM ■■ -/ rir 5-I II11 I I' 1 I I I I I _ _ = i l mmemss, I III I I I 11 R— X1 1 l l a LI-- -- -I- -- - - a 1- -1. -1 1.1 a r a a 1- � a ■r It/ ^r . r/ ��1����rr ///�rl�r�!!!wr!ll����l���! /!! A5- ./ r /rrrrrrrrrrrrrrrrrrrrrrrLr .I /r 5- AI r r r/r/rrrIrr/// Air r r .1rrr ■■rrr rrr■ ■■■rrr■r■rrr■■rrrrrrrrrrrrr5-■■r rrrrrrr ■■ rrrr■rr r■rrrrr■■■rrrr■r■rrrrrr■■rr■rr■ rrr■ r■ r■r r■■rrrr■r■■rrrrrrrrrrr■■■■r5-rrr r a �° ►// '4 ■ r■ ■■■■ rrrrrrrrr■rrr■■r■■rrrrr■ rrrrrrr■ r■ r■ rrrrrr5-rr ■rrrrrrrrrrrrrrrrrr■rrrrrrr ■■■■ ■r rrrr■■rrrrrr■rrrrrrr■■■rrrrrr■ ■■■■ ■rrr■ 1 cal ■Ilrrr■■■rrrrrrrrrrrrrrrr■5-rr5-■ 5-r■■ rrr■■ 5-r■■■ 5-r■■ ■r ■r ■r ■r■■ ■r ■r ■rrr■■■■■■rrr■rr■ rrrr■■ 5-rrr5-5-r■ r■■■■■■■ r■■■■■■ ■r■■rr■rrr■■■rr ■rrr■■rr■rr■■■■■ ■5-r■■■■■■■■■■ rrr■ rrrrrr■ rrrr■■■■■■■■■■■■■■■■■■■■■■■■■■■■ ■rr■■rr■rr■■rr■■ ■r■■5-rrrr■■ ■r■■ ■rrrr■ ■rrrrrrrrrrr■■■■■■■■■■■■ APPROVED P! " ae"r1 7!!.R.1.2. '" NJED, MODIFIED CR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING Or''' ": 1, ALl WORK SHALL SE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND I5 : "'. y T TO F;: '_;" 'NSP:' TIOP;a SEPARATE PERMIT REQUIRED FOR: echanical L7AElectriCal t 'P1umbing ar Gas Piping City of Tukwila BUILDING DIVISION FILE COPY Permit No. 49? REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. Revisions will require a new plan and may include additional plan review fees. 1 Pier review approval Is subject to errors and orIg$SiortS. Approval of construction documents does not authorize the violation of any adopted code or ordinance• Receipt of approved Fie!. and conditions is wed: 3:a1; 4 _ '-5 r- / ! City of Tukwila BUILDING DIVISION Public Works, Building Division PERMIT NUMBER REVIEWMPLiFPC+NCE CODE CO NFPA 70 - NEC IAA( - .1 2008 City Of Tukwila BUILDING DIVISION REVISION Na NOTE SEE ARCHITECTURAL DRAWINGS FOR EXACT MOUNTING HEIGHTS OF ALL DEVICES. NOTE SEE SHEET E1.1 FOR POWER GENERAL NOTES AND POWER CODED NOTES. VERIFY ALL CONDfIIONS IN FIELD PRIOR TO BIDS. TW TUKWILA RECEIVED CITY APR F011008 SEE ELECTRICAL RESPONSIBILTY SCHEDULE ON SHEET E5.0 PERMIT CENTER 25 POWER PLAN 1/4 " =V-0" crazy 8 MEMO CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHfiECT, NCARB, ISP 1450 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146 P,-L (314) 415-2400 FAX (314) 415 -2300 www.arcvcam — m M z CD w w 0 a >NE N 0 SPACE #1220 1036 SOUTHCENTER MALL TUKWILA, WA 98188 w 2 0 CD Id 00 0 CO 3 CO In C4 100% CHECKSET 0 1- m ISSUE TO BID LCT '60G A ON POWER PLAN SHEET NUMBER: E1.0 FILE COPY 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE 6. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS 10. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT 17. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL TYPEWRITTEN SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DMSIONS OF WORK REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. SWITCH IN LANDLORD'S SWITCHGEAR WITH DEMISED PREMISES' SPACE PANEL DIRECTORIES IN ALL PANELBOARDS. AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE NUMBER. WORK OF ALL SUBCONTRACTORS WITH ALL DMSIONS OF WORK. IT IS 7. WHERE DRYWALL C 3 UNGS ARE USED IN THE '"SALES" AREA. THE 18. RECEPTACLES LOCATED IN "GM" SHALL BE WHITE WITH WHFFE THIS COMPACTOR'S RESPONSIBILITY TO PROVIDE ALL ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE 11. NO HANGERS. SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO COVERPLATES. RECEPTACLES LOCATED IN SLATWALL SHALL BE GRAY SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION ROOF DECK. WITH SILVER COVERPLATES. BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS 2. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES 12. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN 19. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A POLY PULL CLARITY. CIRCUITING SHALL BE '"THRU- WIRING" WHERE AND WHENEVER OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY STRING IN ALL EMPTY CONDUITS FOR FUTURE USE SECURE PULL STRING POSSIBLE. GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY AT BOTH ENDS OF CONDUIT. CONFUCTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S 3. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF EXPENSE. 20. ELECTRICAL CONTRACTOR IS NOT TO SHARE THE NEUTRAL CONDUCTOR ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO 8. EQUIPMENT LABELED "GENERAL ELECTRIC" SHALL BE FURNISHED BY GYMBOREE 0 A CIRCUIT F• AI . A 'GFCI" DEVICE WITH ANY OTHER CIRCUIT. ORDERING RELATED ELECTRICAL EQUIPMENT. AND INSTALLED BY THE ELECTRICAL CONTRACTOR. REFER TO CODED 13. RECEPTACLES, VIDEO JUNCTION BOXES AND TELEPHONE OUTLETS SHALL e NOTES, ELECTRICAL RESPONSIBILITY SCHEDULE, PANEL SCHEDULE AND BE MOUNTED HORIZONTALLY AT 18" A.F.F. UNLESS NOTED OTHERWISE. 4. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTIIZE #12 CONDUCTORS POWER RISER DIAGRAM FOR SPECIFIC EQUIPMENT DESCRIPTION. MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101' -0" TO 150' -0" IN LENGTH 14. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CLEAR CHILD- SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 9. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE PROOF COVERPLATES ON ALL RECEPTACLES. 151' -0" UP TO 250' -0" IN LENGTH SHALL UTILIZE 0 CONDUCTORS MINIMUM. LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT CIRCUITS ABOVE 251' -0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. THE LOCATION AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT 15. ELECTRICAL CONTRACTOR IS TO CUT FLOOR (CORE DRILL ON ELEVATED ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL FLOORS) AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND 5. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR PATCH FLOOR TO MATCH EXISTING. COORDINATE ALL WORK WITH INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO LANDLORD PRIOR TO STARTING WORK. TO CORNERS). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME 16. TELEVISION SETS, VIDEO RECORDERS, SPEAKERS AND COAXIAL CABLES GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH -IN. RECEPTACLES OF THE BID, WITHOUT A SEPARATE UNE ITEM FOR THE FIRE ALARM WILL BE FURNISHED AND INSTALLED BY G.C. ELECTRICAL CONTRACTOR IS MOUNTED IN SLAT WALL SHALL BE MOUNTED VERTICALLY AND CENTERED SYSTEM AT THE TIME OF THE BID. TO FURNISH AND INSTALL ALL NECESSARY CONDUITS, PULL WIRES, JUNCTION EVENLY BETWEEN SLAT WALL GROOVES. BOXES, ETC. AS REQUIRED. 21. LANDLORD WILL PROVIDE A COMMUNICATION CAB TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDKORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT G.C. SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANTS SPACE. TENANT G.C. SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. POWER GENERAL NOTES 22. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION 23. TENANT G.C. SHALL FURNISH AND INSTALL DUCT DETECTORS WITH BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN REMOTE TEST SWITCH AND LED INDICATOR LIGHTS IN SUPPLY AND CONNECTION THEIR INDMDUAL FIRE ALARM SYSTEMS OR RETURN MAINS FOR EACH TENANT VAV UNIT AS REQUIRED BY CODE COMPONENTS. TENANT G.C. SHALL FURNISH AND INSTALL ALL AND LOCAL AUTHORITY HAVING JURISDICTION. NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND 24. "CALL SOUTHCENTER MALL SPACE #1220 1036 SOUTHCENTER MALL TUKWILA, WA 98188 VE PROJECT NO: ORM BY: CHECKED BY: 080031 SS ES CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. TENANT G.C. TO PROVIDE FOR AID" SYSTEM IN HANDICAP TENANT G.C. SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE TOILET ROOM. COORDINATE WITH LANDLORD FOR REQUIREMENTS. ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT G.C.'S EXPENSE. TENANT G.C. SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHAL'S OFFICE. REVIEWED COMPLIANCE CODE CO NFPA 70 - NEC j MAY 1 = City Of Tukwila BUILDING DIVISION-:. POWER CODED NOTES 0 DUPLEX RECEPTACLES (AT 6" O.C.), QUADRAPLEX RECEPTACLE, DATA 11 DUPLEX RECEPTACLE IN WALL FOR REFRIGERATOR AND MICROWAVE AT OUTLET AND TELEPHONE OUTLET IN WALL AT 2' -0" A.F.F.. VERIFY EXACT 18" A.F.F.. LOCATION IN FIELD TO CLEAR SAFE ". 1 QUADRAPLEX RECEPTACLE IN WALL AT 6' -2- A.F.F. FOR DVD PLAYER 0 RECEPTACLES AND COVERPLATES DESIGNATED '"SF" SHALL BE MOUNTED FOR TV AMOIRE:. ON THE UNDERSIDE OF THE STOREFRONT SOFFIT WITH THE 4' SIDE 13 ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A 100 WATT PARALLEL TO THE STOREFRONT GLASS. SERVICE LIGHT WITH SWITCH AND GROUND FAULT DUPLEX RECEPTACLE 3 ONE 1 1/4" RIGID GALVANIZED STEEL CONDUIT FOR POWER AND TWO 1" AT UNIT. DEVICES ARE TO BE WEATHERPROOF WHEN USED OUTDOORS. RIGID GALVANIZED STEEL CONDUITS FOR TELEPHONE/DATA CONNECT TO CIRCUIT AS SHOWN. UNDERFLOOR FROM CASHWRAP TO ABOVE ELECTRICAL LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY MauN1NC HGT. TO CENTERLINE MOUNTING HGT. TO Ca1TE%INE SYMBOL DESCRIPTION UNLESS OTHERwSE NOTED SYMBOL o IP1wN UNLESS orHr�wSE Na7En 11 TELEPHONE OURET - 4' SQ. W/PLASTER RING 18• 14 2'W X 4'H X 3 4" TELEPHONE BOARD WITH DEDICATED QUADRAPLEX CEILING AND TO ELECTRIC PANEL OR TELEPHONE TERMINAL BOARD AS � / TIN L OR TELEPHONE HONE E INA 0 GOING OUTLET �-Q WALL OUTLET SEE DRAWINGS CURET SEE DRANINGS VAR ED ruNCTioN Box SEE DRAWINGS MOUNTED LABELED. STUB CONDUITS UP 6' ABOVE FINISHED FLOOR AT CASHWRAP. RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE 04 DUPLEX RECEPTACLES (AT 6" O.C.), QUADRAPLEX RECEPTACLE, DATA COMPANY. EXTEND 1" TELEPHONE CONDUIT WITH PULLWIRE FROM OUTLET AND TELEPHONE OUTLET IN WALL AT 2' -0" A.F.F. FOR I.S.S. SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE BOARD. VERIFY EQUIPMENT. EXACT LOCATION IN FIELD. 05 JUNCTION BOX AND DUPLEX RECEPTACLE IN WALL FOR VIDEO MONITOR. 15 PANEL 'HV", 277/480V., 30, 4W.. MOUNT JUNCTION BOX AND DUPLEX RECEPTACLE IN WALL AT 73" A.F.F.. INSTA 1 1/2" FLEX CONDUIT FROM JUNCTION BOX UP IN WALL TO ABOVE 1B 30 KVA FLOOR MOUNTED STEP-DOWN TRANSFORMER, 480V., 30, 3W. LL. CEILING AND TO NEAREST CEILING DIFFUSER FOR FUTURE CABLING BY PRIMARY, 120/208V.1 30. 4W. SECONDARY. OTHERS. Q PANEL "A ", 120 / 208V.. 30, 4W.. QUADRAPLEX RECEPTACLE IN WALL AT 6' -2" A.F.F. FOR DVD PLAYER. 18 JUNCTION BOX MOUNTED IN WALL AT 6' -2" A.F.F FOR DMX MUSIC SYSTEM ITH 0 ELECTRICAL CONTRACTOR IS TO ROUTE POWER /DATA/TELEPHONE W 1" CONDUIT STUBBED TO 13' -0" A.F.F.. CONDUITS DOWN IN WALL TO BELOW BACKWRAP BASE, STUB OUT CONDUITS IN BASE AREA AND FLEX BACK UP TO DEVICES IN BACKWRAP. 19 SINGLE RECEPTACLE IN WALL AT 12' A.F.F. FOR INSTANTANEOUS WATER HEATER MOUNTED ON WALL UNDER SINK. ■ 8 DELNERY BUZZER SYSTEM PUSHBUTTON AT 54 A.F.F. AND POWER , TRANSFORMER HIGH ON WALL FURNISHED AND INSTALLED BY 0 TIME CLOCK ON WAIL. SEE POWER RISER ELECTRICAL CONTRACTOR. PUSHBUTTON SHALL BE EDWARDS #603 AND ON SHEET "E4.0" FOR ADDITIONAL INFORMATION. TRANSFORMER SHALL BE EDWARDS #596. CONNECT PUSHBUTTON TO POWER TRANSFORMER AS REQUIRED. 07 ELECTRICAL, DATA AND TELEPHONE OUTLET(S) MOUNTED IN CASHWRAP/BACKWRAP. COORDINATE EXACT PLACEMENT OF DEVICE DELIVERY BUZZER SYSTEM BUZZER MOUNT ON WALL AT 9' -O" A.F.F. AND WIRE ROUTING IN CASHWRAP /BACKWRAP WITH MILLWORK FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. BUZZER TO DRAWINGS. BE AN EDWARDS #15 -041. CONNECT BUZZER TO POWER TRANSFORMER AS REQUIRED. 10 DELNERY BUZZER SYSTEM BUZZER ABOVE CEILING FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. BUZZER TO BE AN EDWARDS #660. CONNECT BUZZER TO POWER TRANSFORMER AS REQUIRED. HP W D kI F Di © 0 p Q -el- ® PUBLIC TELEPHONE OUTLET - 4 sQ. w/PLASTER RING 54• CAS TV OUTLET 24' WALL BOX - DIMMER 48" DATA OUTLET - 4• SQ. W/PLAS1ER RING 18' FIRE ALARM BREAK STATION 48' FIRE ALARM AUDIO/VISUAL SIGNAL DEICE 98' DUCT MM. SY51EM SMOKE DEIEC I w/ REMOTE INDICATORS AS REQUIRED FIRE ALARM WATER FLOW SNITCH AS REQUIRED 0 C ILIIG EDT LIGHT MOUNTED EU LIGHT CURET 0 CEILING Pik WALL MID. DDT LIGHT w/ DIRECTIONAL ARROWS SITE DRAWINGS RECEPTACLE, 3 WIRE �. TYPE 18' © 18' GF DUPLEX RECEPTACLE, GROUND FAULT PROTECTED 18• ■DIG DUPLE( RECEPTACLE, ISOLATED GROUND 18• 40 QUAORAPt°c RECEPTACLE 18 $ TOGGLE SNITCH, ENGLE POLE 4a' TOGGLE swIITCH, DOUBLE POLE 4a- ', $s TOGGLE SNITCH, 3-WAY, 4-WAY 48' # MANUAL MOTOR STARTING SWITCH 48" ® MAGNETIC MOTOR STARTER AS REQUIRED Ill COMBINATION STARTER/SAFETY SWITCH AS REQUIRED 1=-I sAFEry SWIM AS REQUIRED ELECTRIC PANEL 8 -0' TO T P MUCH ALARM TAMPER UCH AS REQUIRED SYSTEM SMOKE DETECTOR CEILING MID. SYSTEM PHOTO/HEAT DETEC1DR CEILING M10. SYSTEM HEAT DETECTOR (FIXED TEMP.) CEILING MID. F A FIRE ALARM PANEL AS REQUIRED NORCN BOX AS REQUIRE) ® � E) >ZCSF DUPLEX RECEPTACLE AT STOTEFRONT CEILING M1D. D/ DDJVERY Burma AS REQUIRED DELIVERY BUZZER • =i DELIVERY BUS TRANS TER AS REQUIRED RECEIVED ® MULTI-OUTLET RACEWAY CITY OF TUKWILA AS SECURED 0 CE]L APR 012008 CEILING MM. 11ME CLOCK LOG( AS REQUIRED El LIGHTING CONTACTOR PERMIT CENTER AS IEanRED ® M� OUTLET. EN� PHASE 6 MOTOR OUTLET, THREE PHASE - - - CHAIN HANG UGHTS IN STOCKROOM TO 10' --0' A.F.F.(TYP). '� wr■■n �rrrr■■••rr r••r rr r•rr rr•■r• rr•••rrr•••rrr•r•■•i•r••rrr■•11r rrrr■• rrrrrrr rrrr■■rrrrrrr•rrrrrr■■rrr ■ ■ tai:A:mgemimmEgyingolegimir:11:11:1111119::::::::::::::: ••••••••• •••••••••r••r•••r•••••••••••••■ ■••••••••••••••••r•■ r rrrrrrr•rr•r• rrrrr• rrrrrrrrr• rr•• r••••••• •• rr■•••••• r•••••••••••••••••••• •••••••••••••••••••••••••r•••rr ■rrrrr■ ••rrrrrrr ■ ••rrrr•••• ■rr■ ■rrrrrrr�� imil ������������� I��_ �r•••:■ r•••••••• r••••••••••••••••••••• r••••■ r■••r• r.■••■• ••r•••rr■•rrrrr•rrr■Irrr.r•rrr■ rrrrrrrrrrrrrrrr••••••••••••••• r••••••••••••••••• ••••••••i••••••••••••••••••••i• iii•• rrrrrrrrrr••••••••••• r•••• r••••••• r•••••• rr■•••••• r•••••••••••••••••••••••••••••• r•••••••••••••••• r• rr■■••••• ii••••••• rr'� ■Zrrrrrrr■rrirrr�irrrrrrrrr "r a m s� � r oiiiiiir�rrirsi�y rlii 112::i�:rrii.�.iiiii� iV --, ria �I � /vta s ��i! irJ i% 'il; i 1 1 Li frr� *.. willion-Wir �I ���� ��� Oft A-2 q1 IIIIA I �. i T3 T3 T3 T3 T3 T3 ��:` A- 15____,I' �° via sw d ■ 13 ��eq w T 1 - A MI 11 __ __..... ..miiiiii,... ,,..Milm 1p, ..... �r .115 . _ EL°31110 1 aid C 4 !oY Q 8 y r 11 1 maimm..,,im... • " innin _. • I Vii: A —T /C ji . .�W�_ ti,...mar.-- - _ M.Q � `o O I • Al �A1 f1A IIIMER �� .,.,■�■ I (A1 9A1 or All MI 0. Irrr••••rr■ •rrrr•■■••■ ■•r•rrrr•••rrr•••rrr rrrrrrrrrrrrrrrrrr ■rrrr■ ■rrrrr ■rrrrr• ■r■rrr■rr rrrrr•■■■• rrrrr•• r ••rr•••rrr••••r•rrr••••••rr•I•. Irrr•rr MIII•• r• r• r •r•••r■rr••r■ ■r ■•rrrrrrrrrr• ■ ■■ ■rrrrr•• ■rrrr■rrrrrr■• rrrrr ■r■•rr■rrrrr•r•■1111.11•rrrr rrrrrrrrrr• ■r••r•rrrrrrrrrrrr�� ■• ■ :: II :7 ii .. EN m ., i1Io I.j El ME ME ME ME EN I ■ 1 ii1tUii1E ■ ►1 ME .. rr ma .. ��IMI -h ill I D D �� _ I. K Jr F K K El ii�:: y I - -- i - -- 1 T3 73 T3 T3 T3 T3 T3 v-a T?)] v 0 1 0 1 0111) 1 [(TS 1 L_ - -, I I Al *A1 �___] Al - Al •A1 Al a Q ) a� -h rti T3 T3 T3 T3 T3 T3 13 PI 1 1 1 Ir II•1 1 1 1 1.1 VIA A-T /C -1 I /77777 1• ■.� . �I 1 II ■� ■■ MI- I /I'////!//4•4105 I//////////// / / / / / / / / / / / /L�/%LI / / / / /I / / / / /II / ii�irr iiAiiiiii2ir:. riwiiriruriiiiiiiiiiAri�ii:mgcaw i w! iiur••• r•• r•••• rr• r•r r•r■• rrrrrrrrrrrrrrrrrr■ r• ■■rr•rr••rr•rr■rrrr•11rrrrrrrr■■ rrrrr■■■rrrrrrrrr•r r••• rr ■••r■■rr•r■■■•■■••■••r•■■r■■r•■ rrrrr■ rrrr■ rrrrrrrrrrrr ■rrrrrrrrrrrrrrrr••• •■ rrrr• r■■ Ir rrrrrrrrrrrrr■■ r■■ r■■ r■■ r••■■ r■■■■ ■•rrr••r•rrr••r•rr••rrrrr••rMIN :drll•• ■•• ■•••r•rr■ rrrrrrr■ rrrrr• rr■■■ rrrrrrrrrrrrr ■■rrr11rrrr ■r■■rrrrrrr■rrr•r•■ ■rrrrr ■■r•rrrrrrrrrr•••••••r•r■ rrrr••■•• r•■■■■ ■rr•r••rr•r•■rr•••rr■■■r11lr•rr■ 1111•■■••■ r■■ r■ rE■rrrrrrr3rrrrrrrrr■ ■r■rrrrrr■ rrrrrrr•■ ■r• rrrr•••■■■■ r••■ •r•rr•r•••r•rr•rrr•rr■rrrrrr••. NOTE SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES. VERIFY ALL CONDfT10NS IN FIELD PRIOR TO BIDS. LIGHTING PLAN 1 /4 " =1' -0" 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DMSIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DMSIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE "THRU- WIRING' WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. UGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU- WIRING'. ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 3. SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT LOCATION AND QUANTITY OF UGHTING FIXTURES. 4. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY GYMBOREE. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. 5. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). 6. ALL UGEMNG CIRCUITS UP TO 1OO' -0' IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 101' --0' TO 150' -0' IN LENGTH SHALL U11UZE 110 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS 151' -O' UP TO 250' -0" IN LENGTH SHALL U11UZE 18 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0' SHALL UTIUZE #6 CONDUCTORS MINIMUM. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. WHERE DRYWALL CEIUNGS ARE USED IN THE 'SALES' AREA. THE ELECTRICAL. CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS, THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE UMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN MR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE 9. EXIT /EMERGENCY UGHTS AT STOREFRONT ARE TO BE CEIUNG MOUNTED AND CENTERED OVER OPENING (YYPICAL U.N.O.). EXIT /EMERGENCY LIGHTS AT DOOR TO "NON- SALES" SHALL BE CENTERED ON WALL ABOVE DOOR. SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT LOCATIONS. 10. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A POLY PULL STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. SECURE PULL STRING AT BOTH ENDS OF CONDUIT. NOTE: 2006 IBC -- Sec. 1 006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN NON- VISIBLE LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN FURNISHED BY GYMBOREE ELECTRICAL CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS WITH U.L SECTION 21 61 REQUIRING THE USE OF SECONDARY GROUND FAULT PROTECTION AND INCLUDE ALL COST IN BID. POWER JUNCTION BOX IS TO BE MOUNTED IN CENTER OF SIGN BOTH VERTICALLY AND HORIZONTALLY. STOREFRONT SIGNAGE AND LIGHTING TIMECLOCKS SHALL BE SET TO MALLS OPERATING HOURS. SEE SWITCH BANK DETAIL THIS SHEET. ® PROVIDE WALL MOUNTED EMERGENCY LIGHT WITH 90 MIN BATTERY BACKUP CAPACITY. a b c d ❑ ❑ • ❑ A -15 A -11 A -13 A -21 SALES SALES SALES SALES FLUOR FLUOR PENDANT TRACK LIGHTING LIGHTING LIGHTING LIGHTING 0 0 * T3 73 T3 T3 T3 T3 T3 v-a T?)] v 0 1 0 1 0111) 1 [(TS 1 L_ - -, I I Al *A1 �___] Al - Al •A1 Al a Q ) a� -h rti T3 T3 T3 T3 T3 T3 13 PI 1 1 1 Ir II•1 1 1 1 1.1 VIA A-T /C -1 I /77777 1• ■.� . �I 1 II ■� ■■ MI- I /I'////!//4•4105 I//////////// / / / / / / / / / / / /L�/%LI / / / / /I / / / / /II / ii�irr iiAiiiiii2ir:. riwiiriruriiiiiiiiiiAri�ii:mgcaw i w! iiur••• r•• r•••• rr• r•r r•r■• rrrrrrrrrrrrrrrrrr■ r• ■■rr•rr••rr•rr■rrrr•11rrrrrrrr■■ rrrrr■■■rrrrrrrrr•r r••• rr ■••r■■rr•r■■■•■■••■••r•■■r■■r•■ rrrrr■ rrrr■ rrrrrrrrrrrr ■rrrrrrrrrrrrrrrr••• •■ rrrr• r■■ Ir rrrrrrrrrrrrr■■ r■■ r■■ r■■ r••■■ r■■■■ ■•rrr••r•rrr••r•rr••rrrrr••rMIN :drll•• ■•• ■•••r•rr■ rrrrrrr■ rrrrr• rr■■■ rrrrrrrrrrrrr ■■rrr11rrrr ■r■■rrrrrrr■rrr•r•■ ■rrrrr ■■r•rrrrrrrrrr•••••••r•r■ rrrr••■•• r•■■■■ ■rr•r••rr•r•■rr•••rr■■■r11lr•rr■ 1111•■■••■ r■■ r■ rE■rrrrrrr3rrrrrrrrr■ ■r■rrrrrr■ rrrrrrr•■ ■r• rrrr•••■■■■ r••■ •r•rr•r•••r•rr•rrr•rr■rrrrrr••. NOTE SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL LIGHT FIXTURES. VERIFY ALL CONDfT10NS IN FIELD PRIOR TO BIDS. LIGHTING PLAN 1 /4 " =1' -0" 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DMSIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DMSIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE "THRU- WIRING' WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. UGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU- WIRING'. ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 3. SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT LOCATION AND QUANTITY OF UGHTING FIXTURES. 4. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY GYMBOREE. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. 5. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). 6. ALL UGEMNG CIRCUITS UP TO 1OO' -0' IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 101' --0' TO 150' -0' IN LENGTH SHALL U11UZE 110 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS 151' -O' UP TO 250' -0" IN LENGTH SHALL U11UZE 18 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0' SHALL UTIUZE #6 CONDUCTORS MINIMUM. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. WHERE DRYWALL CEIUNGS ARE USED IN THE 'SALES' AREA. THE ELECTRICAL. CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS, THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE UMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN MR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH GYMBOREE'S PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE 9. EXIT /EMERGENCY UGHTS AT STOREFRONT ARE TO BE CEIUNG MOUNTED AND CENTERED OVER OPENING (YYPICAL U.N.O.). EXIT /EMERGENCY LIGHTS AT DOOR TO "NON- SALES" SHALL BE CENTERED ON WALL ABOVE DOOR. SEE ARCHITECTURAL REFLECTED CEIUNG PLAN FOR EXACT LOCATIONS. 10. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL A POLY PULL STRING IN ALL EMPTY CONDUITS FOR FUTURE USE. SECURE PULL STRING AT BOTH ENDS OF CONDUIT. NOTE: 2006 IBC -- Sec. 1 006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge PROVIDE JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN NON- VISIBLE LOCATION AND FINAL CONNECTION FOR 120 VOLT SIGN FURNISHED BY GYMBOREE ELECTRICAL CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS WITH U.L SECTION 21 61 REQUIRING THE USE OF SECONDARY GROUND FAULT PROTECTION AND INCLUDE ALL COST IN BID. POWER JUNCTION BOX IS TO BE MOUNTED IN CENTER OF SIGN BOTH VERTICALLY AND HORIZONTALLY. STOREFRONT SIGNAGE AND LIGHTING TIMECLOCKS SHALL BE SET TO MALLS OPERATING HOURS. SEE SWITCH BANK DETAIL THIS SHEET. ® PROVIDE WALL MOUNTED EMERGENCY LIGHT WITH 90 MIN BATTERY BACKUP CAPACITY. a b c d ❑ ❑ • ❑ A -15 A -11 A -13 A -21 SALES SALES SALES SALES FLUOR FLUOR PENDANT TRACK LIGHTING LIGHTING LIGHTING LIGHTING A -23 SALES TRACK LIGHTING f A -25 SALES TRACK LIGHTING A -27 SALES TRACK LIGHTING h A -29 SALES TRACK LIGHTING 0 A -33 SALES TRACK LIGHTING CONTRACTOR TO VERIFY EXACT CONFIGERATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48" SWITCH BANK NTa RECEIVED CITY OF TUKWILA APR 012008 PERMIT CENTER LIGHTING GENERAL NOTES LIGHTING CODED NOTES crazy 8 R14116100 CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHITECT, NCARB, ISP 1950 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63148 PH (314) 415 -2400 FAX (314) 416-2300 www.$rcvcam PROJECT INFORMATION: co >- N U J 2 W H z W V 0 5w co 0 co N 100% CHECKSET ISSUE TO BID, PERMIT & co 0 N LANDLORD COMMENTS ,6897 I?E ( STERED ARCHITECT 7, J rrY��'- f"•f''RTi eti fi5s�'�il LIGHTING PLAN SHEET NUMBER: E2.0 LIGHT FIXTURE SCHEDULE Flttir SYMBOL DESCRIPTION MANUFACTURER & MODEL NUMBER DESCRIPTION LAMP WATTAGE H 3 GHT • Al 6" DIAMETER RECESSED COMPACT FLUORESCENT DOWNUGHT, CLEAR CONE, ELECTRONIC BALLAST MAXIWME HV6PL-1X32-E-120/277-6101-CL 9 -1/4' 32 watt, T4, 4Pin GX24q -3 Base, Triple Compact Fluorescent, 3000K, 82 CRT, 10,000 Hrs. PHILIPS: PL-T 32W/30/4P /ALTO OSRAM/SYLVANIA: CF32DT/E/IN /830 GE F32TBX/SPX30 /A /4P 36 watts • AlA 6" DIAMETER RECESSED COMPACT FLUORESCENT DOWNUGHT, CLEAR CONE, ELECTRONIC BALLAST EMERG. BALLAST BACKUP MAXILUME HV6PL- 1X32 -E- 120/277- EMG75O- 6101 -CL 9 -1/4' 32 watt, T4. 4Pin GX24q -3 Base, Triple Compact Fluorescent, 300K n, 3000K, 82 CRT. 0 0, PHILIPS: PL -T 32W/30/4P /ALTO OSRAM/SYLVANIA. CF32DT/E/rN /830 GE F3ZTBX X30 A 4P /SE / / 36 watts • ADJUSTABLE DOME PENDANT FIXTURE WORLD IMPORTS: 9009 -08 24" TO 36' 60W INCAND. MED BASE PHILIPS: 60A OSEAM/SYLVANIA: 60A GE: 60A 60 watts • D1 INCANDESCENT RECESSED DOWNLIGHT HALO: H7U1CT /30CAT 9-1/2* BOW A19 PHILIPS: 60A19 ( 0A/SYLVANIA: 60A19 60 watts • F 2' LONG WALL MOUNTED MIRROR LIGHT LIGHTOLJER: LSW 2 2 17 120 WSO 3 7/8" 2-- 17watt, 11, Medium BI -Pin Base, Linear Fluaresoent, 3000K, 82 CRI, 20,000 Hrs. PHILJPS: F17T8 /830 OSRAM YLVANIA: F017 83D �� /� / 32 watts G2 2' X 2' RECESSED FLUORESCENT TROFFER, HIGH BALLAST FACTOR ELECTRONIC BALLAST, 9 CELL SEMI - SPECULAR PARABOLIC LOUVER, SIMKAR: TEP242- 232U- 9C-B11 -UNV 5 3/4" 2- 32watt, T8, U6, Medium 81-Pin Base, Linear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. PHILJPS: F32T8/TL830 /ALTO OSRAM/SYLVANIA F032/830 GE F32T8/SPX3O 62 watts G2A 2' X 2' RECESSED FLUORESCENT TROFFER, HIGH BALLAST FACTOR ELECTRONIC BALLAST, 9 CELL SEMI- SPECULAR PARABOLIC LOUVER, BACK -UP BATTERY BALLAST SIMKAR: TEP242- 232U- 9C -B11- UNV -EM 2- 32watt, T8, U6, Medium Bi -Pin Base, Linear Fluorescent, 3000K, 82 CRT, 20,000 Hrs. PHILIPS: F32T8/1L830 /ALTO OSRAM /SYLVANIA F032/830 GE: F32T8 /SPX30 62 watts H2 2' X 4' RECESSED FLUORESCENT TROFFER, HIGH BALLAST FACTOR ELECTRONIC BALLAST, 9 CELL SEMI- SPECULAR PARABOLIC LOUVER, SIMKAR: 1EP244- 332- 18C -B11 -UNV 3- 32watt, T8 Medium Bi -Pin Base, Linear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. PHILIPS: F32T8/TL830 /ALTO OSRAM /SYLVANIA: F032/830 GE: F32T8/SPX3O 93 watts H2A 2' X 4' RECESSED FLUORESCENT TROFFER, HIGH BALLAST FACTOR ELECTRONIC BALLAST, 9 CELL SEMI- SPECULAR PARABOLIC LOUVER, BACK -UP BATTERY BALLAST SIMKAR: 1EP244- 332- 18C -B11- UNV -EM 3- 32watt, T8 Medium Bi -Pin Base, Linear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. PHILIPS: F32T8/7L830 /ALTO OSRAM/SYLVANIA F032/830 GE F32T8/SPX30 93 watts • -4 ' 4' BARE LAMP FLUORESCENT STRIP, ELECTRONIC LOW BALLAST LL FACTOR BAAST, 1 LAMP IN SIMKAR: CH132 -B11 -UNIV 3 1 /4" 32 Watt, T8, Medium Bi -Pin Base, Linear Fluorescent, 82 CRT, 20,000 Hrs. PHILIPS: F3218/7L830 /ALTO OSRAM/SYLVANIA: F032/830 GE F32T8/SPX30 31 watts WIRE GUARD L2 -6' 6' BARE LAMP FLUORESCENT STRIP, ELECTRONIC LOW BALLAST FACTOR BALLAST, 1 LAMP IN SECTION WIRE GUARD SIMKAR: CH2125 -B11 -UNIV 3 1/4- 2- 25watt, T8, Medium Bi -Pin Base, Linear Fluorescent, 3000K, 82 CRT, 20,000 Hrs. PHILIPS: F25T8/830 OSRAM/SYLVANIA F025/830 GE F25T8/SPX30 48 watts • �_8 8" BARE LAMP FLUORESCENT STRIP, ELECTRONIC LOW BALLAST FACTOR BALLAST, 1 LAMP IN SECTION. (2) 4' SECTIONS TANDEM WIRED ON ONE BALLAST, QUICK CONNECT PLUGS WIRE GUARD SIMKAR: CH2132 -1311 -UNIV 3 1/4'" 2 -32 Watt, 1T3, Medium Bi -Pin Base, Linear Fluorescent, 20000, Hr CRT, 20.000 Hrs. PHILIPS: F32T8/tL830 /ALTO OSRAM /SYLVANIA F032/830 GE F32T8/SPX30 62 watts • L2E -4, 4' BARE LAMP FLUORESCENT STRIP, ELECTRONIC LOW BALLAST FACTOR BALLAST, 1 LAMP IN SECTION, EMERGENCY BATTERY BACKUP WIRE GUARD SIMKAR: CH132 -ELS -BIT -UNIV 3 1/4' 32 Watt, T8, Medium BI -Pin Base, Linear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. PHILIPS: F32T8/1L830 /ALTO OSRAM/SYLVANIA F032/83O GE F32T8 /SPX30 31 watts • M TOILET ROOM EXHAUST FAN AIRZONE PA900VL 7 -3/4" - - 51 watts • T3 PAR 38 REAR LOADING GIMBAL RING TRACK HEAD, MATTE WHITE FINISH CON -TECH: CTL2838N -P 10 1/8" 45 watt, PAR38, Medium Screw Base, Quartz Halogen Flood PHILIPS: 45PAR38/NFL GE 45PAR/H/F1- PHILIPS: 45PAR /CAP/FL 45 watts • Ts SURFACE MOUNTED SINGLE CIRCUIT TRACK, MATTE WHILE FINISH CON -TECH: LT2P, LT4P, LT6P, LTT3P, LT12P as required 11/16' - - 60 watts • X1 EXIT SIGN EXITRONIX: VEX-- U- BP -WB- -%111 - - - 2 watts RECEIVED CITY OF TUKWILA APR 012008 PERMIT CENTER LIGHTING FIXTURE SCHEDULE crazy 8 R14116Ni? CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLiA ARCHITECT, NCARB, ISP s50 CRAIG ROAD, SUITE 300 S7. LOUIS, I 10 63146 PH (314) 41:x2400 FAX (314) 415-2300 www.ercv com LATE I PROJECT INFORMATION: LA _I Q C _1 _1 CO W H w co co co Z z rn W N CSI N= ct = N I... HTh oa =w° v c...) Oa l 1 w 0) 100% CHECKSET 0 J ISSUE TO BID, PERMIT & co 0 N LANDLORD COMMENTS •iER IiLGI "•,. �` . !. GQG�IA , WASHINGTON LIGHTING FIXTURE SCHEDULE SHEET NUMBER: E3.0 Panel Wires Schedule (8- Flaw) Panelboard Panel Type NEMA Type Endosure A AO 1 Voltage 120 /208 Phase _3_ Wire 4 AIC Rating 10,000 Mains 100A -3P MCB Mains Rating 125 AMP Mounting SURFACE Options Note Ckt. Na �e Load Description Brlr Slze Brkr �� NEC. KW Acted Phase Actual N.E.C. Brla �� Brkr Size Load Description Zone act. Na 1 T/C SIGN -- LO 1.200 1.200 A - -- - -- - -- - -- SPARE .38 2 3 T/C SHOW WIN. REC. 1 50/3 LO 0.360 0.360 B 0.360 0.360 LO ,15/3 1 TELEPHONE BD. AIR CONDITIONING SYSTEM 4 5 T/C ENTRY LTS. 1,0 +25x uRGESr LO 0.108 0.108 C 1.500 1.500 LO 0.750 CASH REGISTER - -- 6 7 T/C SHOW VAN. LTS. - -- LO 1.044 0.624 A - -- ---- 34.459 - -- SPARE UNIT. 8 9 SHOW WIN. REC. - -- LO 0.360 0.360 0 0.200 0.200 LO - -- TIMECLOCK 10 11 SALES LTS. - -- 0.648 0.648 C 0.360 0.360 - -- BACKWRAP 12 13 SALES LTS. - -- 0.612 0.612 A 0.540 0.540 - -- SALES RECEPTS. 14 15 SALES PENDANTS - -- 1.080 1.080 B - -- - -- - -- SPARE 16 17 SPARE -- --- - -- - -- C 0.360 0.360 - -- SALES RECEPTS. 18 19 NL/EM SALES/NS LO 0.184 0.184 A 0.720 0.720 CASHWRAP 20 21 SALES TRACK 1.050 1.050 B 1.800 1.800 LO MICRO./REFRIG. 22 23 SALES TRACK 1.350 1.350 C 1.500 1.500 LO I.S.S. RACK 24 25 SALES TRACK 1.800 1.800 A 0.360 0.360 LO MANAGER'S DESK 26 27 SALES TRACK 0,900 0.900 B 0.460 0.460 NS REC/BUZZER 28 29 SALES TRACK 1.350 1.350 C 0.750 0.750 LO WATER HEATER 30 31 NON -SALES LTS. 0.269 0.269 A 0.720 0.720 LO SOUND SYSTEM 32 33 SALES TRACK 1.050 1.050 6 0.500 0.500 LO I.S.S. RACK 34 35 SPARE - -- - -- C 0.280 0.280 LO RTU LT/REC 36 37 SPARE ---_ -- -_ A - -- - -- SPARE 38 39 SPARE - -- - -- B - -- - -- SPARE 40 41 SPARE - -- - -- C - -- - -- SPARE 42 Notes •All circuit bredcers to be 20-Amp, 1-Pole unless otherwise noted. Zones marked T/C to be routed via timedock Actual Load Totds:01.9 kw gB 7.820 kw 8.206 kw Totd 23.475Joy N.E.C. Connected Totals M► 7.448 kw dB 7.820 kw gG 8.206 kw Total 23.475 kw (All Phases to be balanced to within 7% using Acted Load Totds.) Broakerticn5 AS - Powerlirdc AS Breaker LO - Handle lock -off device ST - Smart Trip Type AUX - Auxilay Contacts PA - Handle Padock Attachment G;FCI -- Ground Fault (trait Interruppter HACR - Heating, A/C & Patel Wihtlp Schedule a- Phase) Panelboard Panel Type NEMA Type Enclosure 1 HV AE Voltage 277/480 Phase _3_ Wire Mains 225A -3P MLO Mains Rating 225 AMP Mounting SURFACE Options AIC Rating 14,000 Note Ckt. Na Zone Load Description Brkr Size Brie Opts N.EC. KW Actual KW Phase Acted KW N.EC. KW Brl� Brio. Size Load Description Zan. Ckt, 1 - -- 120V, 10 -- 0.75 7.449 7.449 A 2.498 2.498 - -- - -- 1.0 < 1o�i1NG Q5 RalANG KW .38 2 3 VAV -1 30kwa XFMR 1 50/3 LO 7.820 7.820 B 2.498 2498 LO ,15/3 1 VAV -1 AIR CONDITIONING SYSTEM , 4 5 14.358* 7.494* 1,0 +25x uRGESr 7.897* 8.206 8.206 C 2.498 2.498 HACR 0.750 MISCELLANEOUS - -- 6 7 - -- SPACE - -- TOTAL NO - -- - -- A - -- - -- 34.459 - -- SPACE UNIT. 8 9 SPACE - -- - -- - -- B - -- - -- - -- SPACE , 10 11 SPACE - -- - -- - -- C - -- - --- - -- SPACE 12 13 SPACE - -- - -- - -- A - -- - -- - -- SPACE 14 15 SPACE - -- - -- - -- B - -- - -- - -- SPACE 16 17 SPACE -- --- - -- - -- C -- -- -- -- - -- SPACE 18 Notes • M dreuit breakers to be 20 -Amp, Actud Load Total 0A 9.947 kw 0E1_10.318.10 0C_11.71410 Total 30.969 kw EQUIPMENT WIRING SCHEDULE SYM. ITEM VOLTAGE HP. KW. F.LA. FEEDERS TYPE OF CONN. BRANCH BREAKER DISC. SW. BUSS FUSES REMARKS %ARE COND. SHOW WINDOW UGHTING ALLOWANCE - -- 120V, 10 -- 0.75 -- fl z N 3/4" SINPLUG S & CORD RECEPTACLE 20A-1P - -- - -- 1.0 < 1o�i1NG Q5 RalANG KW .38 TEP C VAV -1 480V, 30 -- 7.5 -- jig GRD 3/4" DIRECT 15A -3P HACK 30AS 15AF ,,, ,__ _ ___* LANDLORD LEASE LINE SPACE 4#3/0 THHN AND 1#4 GROUND IN A 2" CONDUIT LANDLORD PROVIDED AT TENANT G.C.'S EXPENSE. 1 -Pale unless otherwise noted. N.E.C. Connected Totals 0A 9.947 kw dB 10.318 kw AC_14.704iaw Total 30.969 kw (All Phases to be bdmced to within 7% using Actud Load Totals.) 600V,200A.S. 200 A.F. LANDLORD PROVIDED AT TENANT G,C.'S EXPENSE TENANT G.C. TO RELOCATE SWITCH. LANDLORD'S 277/480V,3PH,4W DISTRIBUTION SWITCHBOARD. METER BY LANDLORD AT- TENANT G.C.'S EXPENSE. THE LANDLORD -OWNER NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION. PNL "HV' SEE PANEL SCHEDULE SEE PANEL SCHEDULE 200A -3P CIRCUIT BREAKER LANDLORD PROVIDED AT TENANT G.C.'S EXPENSE Bracken Oatisa AS - Pouerlidc AS Bredcer 10 - Handle lock -off device ST - Shunt Trip Type AUX - koala-if Cantacta PA - Honda PPadlock Attachment CFO - Ground Fault Circuit In HMR- Heating, A/C &R ROOF CEILING NEW 7 -DAY, 24 -HOUR ELECTROMECHANICAL TIME CLOCK TORK #W400. 443 THHN AND 1#8 GROUND IN A 1 1/4° CONDUIT BY TENANT G.C. NOTE ELECTRICAL CONTRACTOR IS TO COORDINATE ALL GENERAL ELECTRIC EQUIPMENT, PROVIDED BY GYMBOREE TO JOB SITE, WITH GENERAL ELECTRIC REPRESENTATIVE LEO ALANES AT (508) 870 -2402 FOR CORRECTNESS OF EQUIPMENT ON GTE AND WITH ANY INSTALLATION QUESTIONS. POWER REM NTS THHN GROUND TO BUILDING STEEL BY ELECTRICAL CONTRACTOR. NEW 30 KVA STEP -DOWN XFMR. FLOOR MOUNTED, 480 VOLT, 3 -PHASE, 3 -WIRE PRIMARY, 120 /208 VOLT, 3- PHASE, 4 -WIRE SECONDARY. ELECTRIC LOAD SUMMARY 277/480V SYSTEM DESCRIPTION ACTUAL CONNECTED KW/KVA POWER FACTOR ACTUAL DEMAND KVA N.E.C. CONNECTED KW/KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KVA UGHTING 12.345 • 12.345 12.345 1.25 15.432 SHOW WINDOW UGHTING ALLOWANCE - -- • _ -- -- ** 1.25 ___ RECEPTACLES .38 1.0 .38 .38 1.0 < 1o�i1NG Q5 RalANG KW .38 MOTORS - -- 0.9 - -- ___ 1.0 LARGEST +ZS+25% �cESr FIXED ELECTRIC SPACE HEATING - -- * 1.0 - -- * - -- • 1.0 _ ___* AIR CONDITIONING SYSTEM 7.494* 1.0 14.358* 7.494* 1,0 +25x uRGESr 7.897* ELECTRIC WATER HEATER 0.750 1.0 0.750 0.750 1.0 0.750 MISCELLANEOUS - -- 1.0 - -- - -- 1.0 - -- TOTAL NO 30.969 TWO CATEGORIES INSTALLED OF COMPRESSOR INCLUDED . MINIMUM 30.969 30.969 VA, ONLY ON ONE 34.459 VALUE OF THE 220-12 REQUIREMENT MINUS ACTUAL MOTOR IS ALREADY KVA 1.1000 (200VA PER FOOT OF SHOW WINDOW LIGHTING IN SYSTEM. APPLIED IN LIGHTING LOAD. FEEDER AMPERAGE UNIT. * USE GREATER ** N.E.C. ARTICLE SHOW WINDOW) *** 125% OF THE LARGEST • POWER FACTOR JV.EC. DEMAND SYSTEM VOLTAGE x 43 34.459 x 1000 = 41.5 AMPS 480 x 1.73 4q7 NOTES 1. ALL PANELBOARDS, TRANSFORMERS, DISCONNECT SWITCHES, MANUAL MOTOR STARTERS, MAGNETIC STARTERS, LIGHTING CONTACTORS, CIRCUIT BREAKERS IN NEMA ENCLOSURES, ETC. ARE TO BE MANUFACTURED BY GENERAL ELECTRIC AND FURNISHED BY GYMBOREE TO THE PROJECT FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. 2. ALL NECESSARY FUSES ARE THE RESPONSIBILTY OF THE ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL SEE EQUIPMENT WIRING SCHEDULE AND POWER RISER FOR FUSE SIZES. 3. ALL TRANSFORMERS ARE TO MANUFACTURED IN COMPLIANCE WITH NEMA TP -1 STANDARDS. RECEIVED CITY OF TUKWILA APR 012008 PERMIT CENTER ELECTRICAL SCHEDULES AND POWER RISER crazy8 mane CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHITECT, NCARB, ISP 195o CRAIG ROAD, SUM 300 ST. LOOS, MO 63145 PH (314) 415x2400 FAX (314) 415x2300 www.ercv.com w t CCI 2 CI ZCC) w PROJECT INFORMATION: oo } N U J 2 H z W U 0 low co OD N 100% CHECKSET co 1 N a 0 J ISSUE TO BID. PERMIT & co a LANDLORD COMMENTS ',891 c.. s TERED 1 ELECTRICAL SCHEDULES AND POWER RISER SHEET NUMBER: E4.0 DIVISION 16000 - ELECTRICAL SECTION 16001 - BASIC ELECTRICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16000. 2. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBIUTY IN PERFORMANCE OF WORK. 5. REFER TO RESPONSIBILITY SCHEDULE FOR INFORMATION IN REGARD TO RESPONSIBIUTY OF WORK OR ITEMS WHICH MAY AFFECT BID. SECTION 16002 - GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR GYMBOREE SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE GYMBOREE PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH 15 NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH 15 OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING ACCESS PANELS FOR SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. SECTION 16003 - CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPUCABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE UNE ITEM IN THE BID. AFTER CONTRACT 15 ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY GYMBOREE TO THE CONTRACTOR. SECTION 16004 - LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. 2. FURNISH TO GYMBOREE'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. SECTION 16005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY GYMBOREE'S PROJECT MANAGER THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. 2. ELECTRICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO GYMBOREE'S PROJECT MANAGER FOR APPROVAL SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR GYMBOREE'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF GENERAL CONTRACTOR AND THE SUB - CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. SECTION 16006 - GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY GYMBOREE'S PROJECT MANAGER. EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. GYMBOREE SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY GYMBOREE AND GYMBOREE'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. SECTION 16007 - RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: A. LOCATION OF CONCEALED CONDUIT AND WIRING. B. LOCATION OF JUNCTION BOXES. C. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. D. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE DELIVERED TO GYMBOREE'S PROJECT MANAGER. SECTION 16008 - DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEM. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE GYMBOREE'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, GYMBOREE'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. SECTION 16009 DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. ELECTRICAL CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING LIGHT FIXTURES, RECEPTACLES, SWITCHES, ETC. NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED CONDUITS OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR AND GYMBOREE PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND GYMBOREE. ALL UNUSED EXISTING PLENUM RATED CABLING IS TO BE REMOVED COMPLETELY. SECTION 16010 - CUTTING AND PATCHING 1. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR ENGINEER. 2. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FINISH AND SHALL MATCH ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND GYMBOREE'S PROJECT MANAGER. 3. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND GYMBOREE'S PROJECT MANAGER. SECTION 16011 - SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. SECTION 16012 - HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CUPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT CONDUIT OR BOXES, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. DIVISION 16200 - ELECTRICAL SECTION 16201 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR REASONABLY IMPLIED AND INCIDENTAL TO THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEM AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, U r T F• • 1 1. NO WORK EXCEPT FOR INSTALLATION OF NAMEPLATE SHALL BE DONE IN LANDLORD'S ELECTRICAL /METER ROOMS. 0 ' ' • ' ' 1 ' 1 1 •N YS EMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM. 3. COMPLETE LIGHTING FIXTURE INSTALLATION. 4. COMPLETE TELEPHONE CONDUIT SYSTEM, INCLUDING SERVICE CONDUIT FROM POINT OF CONNECTION TO LANDLORDS SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC.. 5. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION. 6. WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER. 7. PROVISIONS FOR FIRE ALARM /SMOKE EVACUATION SYSTEM AND EXTENSION TO LANDLORDS SYSTEM (IF APPLICABLE). 8. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. 9. TESTING OF ALL ELECTRICAL EQUIPMENT. 10. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE -OUT. B. PROVIDE ELECTRICAL SERVICE AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE LANDLORD AND THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL UTILITY COMPANY FOR INSTALLATION OF METERING AS REQUIRED BY THE LANDLORD. C. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT (IF REQUIRED BY LANDLORD OR LOCAL CODE) FOR TELEPHONE SYSTEM WITHIN THE LEASED SPACE. OUTLET BOXES SHALL BE 4n SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. D. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. SECTION 16202 -- MATERIALS A. MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY UST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. B. CONDUIT SHALL BE STANDARD STEEL, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS. EXCEPT AS OTHERWISE APPROVED BY GYMBOREE'S PROJECT MANAGER. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. MINIMUM SIZES OF CONDUIT SHALL BE 3/4", EXCEPT 1/2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO - GALVANIZED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE THE SUSPENDED CEILING OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. USE IMC FOR UNDER SLAB INSTALLATIONS. IMC IS PERMITTED WITH SCREW CONNECTIONS. FLEXIBLE METALLIC TUBING MAY BE USED IN LIEU OF EMT FOR CONCEALED BRANCH CIRCUIT WIRING ONLY, WHERE PERMITTED BY LOCAL AUTHORITIES. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT, PERMITTED BY CODE. C. ALL CONDUCTORS SHALL BE SOF? DRAWN, ANNEALED COPPER, WITH 600 VOLT INSULATION: 1. #10 AND SMALLER - SOLID. #8 AND LARGER - STRANDED. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 3. GENERAL WIRING SHALL HAVE THHN INSULATION. 4. ALUMINUM CONDUCTORS, ROMEX OR BX ARE NOT PERMITTED. 5. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCH -LOCK FOR #8 AND SMALLER, AND T & B LOCK -TITE FOR #6 AND LARGER. 6. WIRES SHALL BE COLOR CODED IN KEEPING WITH LANDLORD'S CONVENTION. D. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, 4n X 4 ", KNOCK -OUT TYPE WITH FIXTURE STUDS AS REQUIRED. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. E. WIRING DEVICES: 1. DEVICES AND COVERPLATES SHALL BE SPECIFICATION GRADE WITH A MINIMUM OF RATING OF 20 AMPS. 2. COLOR OF DEVICES AND COVERPLATES ARE TO BE AS FOLLOWS: - RECEPTACLES WITHIN THE SALES AREA SLATWALL AREA ARE TO BE GRAY W SILVER COVER PLATES. - ALL OTHER RECEPTACLES & COVER PLATES WITHIN GYP. BD. AREAS ARE TO BE IVORY. HUBBELL EQUALS BY LEVITON OR COOPER WIRING DEVICES /EAGLE ELECTRIC. DUPLEX RECEPTACLE: HUBBELL #5262 QUADRAPLEX RECEPTACLE: (2) HUBBELL #5262 UNDER ONE (TWO GANG TYPE) COVERPLATE ISOLATED GROUND RECEPTACLE: HUBBELL #IG -5262 QUADRAPLEX ISOLATED RECEPTACLE: (2) HUBBELL #IG- (TWO GANG TYPE) 5262 UNDER ONE COVERPLATE WEATHERPROOF RECEPTACLE: HUBBELL #GF- 5262 -I WITH "WP26" ALUMINUM COVERPLATE SPST SWITCH: HUBBELL #HBL -1221 THREE WAY SWITCH: HUBBELL #HBL -1223 F. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTIONS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND N.E.C. CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO PROTECT GROUND WIRE FROM DAMAGE TO A HEIGHT OF 6 FEET ABOVE FLOOR. MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL THREE WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO BUILDING STEEL. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON - METALLIC CONDUIT. A SEPARATE ISOLATED, INSULATED GROUND SYSTEM SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTERS. G. ALL PANELBOARDS SHALL BE STANDARD DEAD -FRONT CONSTRUCTION WITH SIZE AND NUMBER OF SINGLE AND MULT1 -POLE BOLT -ON BRANCH BREAKERS AS INDICATED ON THE PANEL SCHEDULE, AND WITH MAIN BREAKER AND MAIN LUGS AS INDICATED ON THE DRAWINGS. PANEL BUSSING SHALL BE COPPER. PANELBOARDS SHALL BE COMPLETE WITH TRIM, DOOR, CONCEALED HINGES, FLUSH LOCK, DIRECTORY FRAME AND NEATLY TYPED COMPLETED DIRECTORY CARDS. ALL PANELBOARDS SHALL HAVE DISTRIBUTED BUSSING AND SEQUENCE NUMBERING WITH NO TWO CONSECUTIVE CIRCUIT NUMBERS TIED TO THE SAME BUS OR PHASE. ALL PANELS AND BREAKERS ARE PRE - PURCHASED AND SHALL BE GENERAL ELECTRIC AS PART GYMBOREE'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. ALL CIRCUIT BREAKERS USED FOR CONTROL OF LIGHTING CIRCUITS SHALL BE "SWD" RATED. H. DRY TYPE STEP -DOWN TRANSFORMER SHALL HAVE NEMA CLASS F INSULATION ON UNITS BELOW 30 KVA AND NEMA CLASS H INSULATION ON UNITS 30 KVA AND ABOVE. TRANSFORMER TO BE GENERAL PURPOSE VENTILATED TYPE WITH ALUMINUM WINDINGS. TRANSFORMER IS PRE - PURCHASED AND SHALL BE GENERAL ELECTRIC AS PART GYMBOREE'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. I. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, 600 VOLT RATED, QUICK -MAKE /QUICK - BREAK, WEATHERPROOF (WHERE APPLICABLE), FUSED /NON -FUSED AS SHOWN ON THE DRAWINGS. SWITCHES USED FOR SERVICE ENTRANCE SHALL BE nSE" RATED. STARTERS SHALL BE MINIMUM NEMA SIZE 1. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT SWITCHES ARE PRE - PURCHASED AND SHALL BE GENERAL ELECTRIC AS PART GYMBOREE'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. J. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRIC SERVICE AND MAKE CONNECTIONS TO THE HVAC EQUIPMENT, SIGNS AND GRILLE MOTORS (IF APPUCABLE) AS SHOWN ON THE DRAWINGS. K. THE ISOLATED CIRCUIT OUTLETS AT CASH WRAP AREAS SHALL BE CLEARLY AND COMPLETELY MARKED FOR UNMISTAKABLE IDENTIFICATION BY THE OWNER'S EMPLOYEES. L. TEMPORARY WIRING SHALL BE REMOVED WHEN WORK IS COMPLETED. M. NO CONDUIT SHALL BE RUN THROUGH HVAC DUCTS. N. FINALLY 1 IT I5 THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETED IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING ARE APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. REVIEWED FOR CODE COMP LIANCE NFPA 70 -NEC MAY -1 2008 City Of Tukwila B ILDING DIVISION. ELECTRICAL RESPONSIBILITY SCHEDULE ITEM BY INSTALLED INSTA BY RE -USE EXISTING N/A REMARKS GYMBCREE LANDLORD C NTR. uwaLORD cON IR MAIN C 0 LANDLARD'S ELECTRIC ROOM • • • G iE Gp SE METER N LANDLORD'S ELECTRIC ROOM • • • AT TENANT G.C. E>4PENSE c/YS IN LANDLORD'S ELECTRIC ROCK • SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE • • • AT TENT AN G.C. EASE SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE • • • TENT TENANT G.C. EXPENSE 277/480 VOLT PANEL(S) • • STEP DN. UNE TRANSFORMERS & MOUNTING ACES (AS REQUIRE* • • 12O/,208 VOLT PANEL • • HVAC DISCONNECT SNATCH • • MANUAL MOTOR STARTER(S) • METER IN LEASE SPACE • C/N's IN LEASE SPACE • c/rs CABIIIET IN LEASE SPACE • LIGHTING FIXTURES AND LAMPS • • TOILET EXHAUST FAN(S) • • ALLED BY MSC.. MBiED BY EC. RECEPTACLES IN SALES AREA • • RECEPTACLES IN STOCKROOM AREA • • POMNER MAKING TO HVAC EQUIPMENT • • LIGHTING CONTACTORS • • POVE'RR IMRWG TO -CAS RRAP" • • POWER MIRING AND COMDR FOR SNNSORMATIC EQUIPMBIT • FLOOR BODES AND COVERS • DEUW RY BUZZER SYSTEM • • - TELEPHONE CABLE CONDUIT MATH PLUNK • • DATA CABLE CONDUITS WTH PULLMIRE • • TELEPHONE CABLING AND JACKS • INSTALLED BY GYMBOREE SMCTKE DETECTOR W FET iit4 CR SUPPLY AIR DUCT • FIRE ALARM SYSTEM • MUSIC SYS'TD�N/s ENK3RS/cAN NEr • INSTAIJ ID BY GYMBOREE MUSIC SYSTEM WIRING /CONDUIT • • PRE -WRE BY GYNBOREE - CONDUIT BY G.C. R.T.U. SERVICE RECEPTACLE • • TIME CLOCC • • 2 -11RE LIGHTING CCNTRCL RELAY • • AS -BUILT DRAWNGS • • RECEIVED CITY OF TUKWILA APR 012008 PERMIT CENTER ELECTRICAL SPECIFICATIONS crazy 8 mem CORPORATION 500 HOWARD STREET SAN FRANCISCO, CALIFORNIA 94105 FREDERICK J. GOGLIA ARCHITECT, NCARB, ISP ?350 CRAIG ROAD, SUITE 300 ST. LOUIS, MO 63146 PH" (314) 415 -2400 FAX (314) 415-2300 www.ercvcom PROJECT INFORMATION: co } N U J 2 W 1- z W U 0 to 1 0) 100% CHECKSET ISSUE TO BID, w LANDLORD C r, STEREO CT 71.4„: I� if i, .1. GOGL I�A WASHINGTON ELECT. SPECS/ RESPONSIBILITY SCHEDULE SHEET NUMBER: E5.0