HomeMy WebLinkAboutPermit EL08-0204 - WESTFIELD SOUTHCENTER MALL - FYE2636 SC MALL 07-24-08 ELO8-204 Cityef Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Permit Number: EL08 -204 Address: 2636 SOUTHCENTER MALL TUKW Issue Date: OS/30/2008 Suite No: Permit Expires On: 12/16/2008 Tenant: Name: FYE Address: 2636 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DEVON REDMON Phone: 310 328 -6300 Address: 1327 POST AV, STE H , TORRANCE CA Contractor: Name: NEAL ELECTRIC INC Phone: 425 471 -1654 Address: 23036 NE 29 ST , SAMMAMISH WA Contractor License No: NEALEI *022M9 Expiration Date: 09/19/2008 DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL LIGHTING, RECEPTACLES, AND ELECTRICAL PANELS REVISION #1 INCLUDES ADDING TEMP PANEL TO PERMIT. Value of Electrical: $19,000.00 Fees Collected: $585.75 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be compile x. wi Date: a/0-101 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: 074 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -204 Printed: 06-27 -2008 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2636 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -204 Issue Date: 05/30/2008 Permit Expires On: 11/26/2008 Tenant: Name: FYE Address: 2636 SOUTHCENTER MALL , TUICWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DEVON REDMON Phone: 310 328 -6300 Address: 1327 POST AV, STE H , TORRANCE CA Contractor: Name: NEAL ELECTRIC INC Address: 23036 NE 29 ST , SAMMAMISH WA Contractor License No: NEALEI *022M9 Phone: 425 471 -1654 Expiration Date: 09/19/2008 DESCRIPTION OF WORK: TENANT IMPROVEMENT: INSTALL LIGHTING, RECEPTACLES, AND ELECTRICAL PANELS Value of Electrical: $19,000.00 Fees Collected: $492.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature:,, Date: [S-/9A `0 0 I hereby certify that I have read and xa ;ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfo ance of work. I am authorized to sign and obtain this electrical permit. Signature: �— Date: 1136/PS Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -204 Printed: 05-30 -2008 � • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2636 SOUTHCENTER MALL TUKW Suite No: Tenant: FYE Permit Number: EL08 -204 Status: ISSUED Applied Date: 03/03/2008 Issue Date: 05/30/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, arty violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Date: S/30/0 g C L lI L Print Name: doc: Cond -Elec EL08 -204 Printed: 05 -30 -2008 CITY OF TUKWILIP Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 I1ttp: /Avtvvi.ci tiikivda. tva.us • Electrical Permit No. Project No. f1}N 261 COS -05D (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 50 ( N`�\\ Tenant Name: P. 1 . c - Property Owners Name: Mailing Address: ! / 6 0/ King Co Assessor's Tax No.: r -.3L 'I-� - D() / Suite Number: 2tteC F oor: New Tenant: Yes ❑ ..No CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: ‘)0,./N. Pe. ���,� Day Telephone: 31 d 3.��' -6 O der /L Mailing Address: \ 2 171)1+- A'-"LC. 54e. City State Zip E -Mail Address: V ' 9 �X� '- 5Xpef' h1 i Cec -tax Number: 7/ U �s ��� ee- ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 1 ` t O O0 Scope of Work (please provide detailed information): Iv‘S \-u'\ \ 1 (,L ,If/ a-5 1VAC- 11ctt—,L4 i�v� k' atre-�74.7f-s., a P Will service be altered? ❑ Yes No Type of Use: IY 1'e rc c - ^�1 Tyne of work: New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: Puget Sound Energy ❑ Seattle City Light Adding more than 50 amps? ❑ YesNo ❑ Service Change ❑ Remodel \ Tenant Improvement ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service HAApphcalionsWFom s- Apphcatons On Irnt4 -2007. Electncal Pmt Applicanon.doc bh Page 1 of 2 1 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair S65.00 ❑ Low voltage systems 555.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: %27 i et /A? 9 Z c r� Mailing Address: Tr #� Date Application Accepted: obi ,��IO97 i Date Application Expires: HApplicanons\Forms- Applications On IJnet4 -2007 - Electrical Permit Apphcationdoc bh Date: 3/3x0 Y/ Day Telephone: 5'.i -f /P City Oct I irf4 Lc) >4 State Staff Initials: Rg Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http.• / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -204 Address: 2636 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 03/03/2008 Applicant: FYE Issue Date: 05/30/2008 Receipt No.: R08 -02327 Initials: JEM User ID: 1165 Payment Amount: $75.00 Payment Date: 06/27/2008 10:23 AM Balance: $0.00 Payee: NEAL ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 75.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 75.00 Total: $75.00 4186 06/27 9711 TOTAL 75.00 doc: Receipt -06 Printed: 06-27 -2008 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http../Iwww.cittikwila.wa.us SET RECEIPT RECEIPT NO: R08 -00594 Initials: JEM Payment Date: 03/03/2008 User ID: 1165 Payee: EXPRESS PERMITS Total Payment: 714.30 SET ID: S000000972 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -115 520.65 .,EL0f84:bat 98.40 M08 -061 63.25 PG08 -066 32.00 TOTAL: 714.30 TRANSACTION LIST: Type Method Description Amount Payment Check 11076 714.30 TOTAL: 714.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 98.40 000/345.830 615.90 TOTAL: 714.30 :1 U/03 T710 TOTAL 714.7_i CI•44 0'204 INSPECTION NO. PERMIT NO. ; CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 67 INSPECTION RECORD Retain a copy with permit Project: r Y 6 Type of Inspection: ;10V Address: 2- % ° it Date Called: Special Instructions: / Date Wanted: ,� a:m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: LtrJ&' ek (Date: 047-tier ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit kol-vaki PERMIT NO. Tr— (206)431-36 V0 Project: ri E., Type of Inspection: `� Address: 70 4 1 r Date Called: �"--..., Special Instructions: Date Wanted: 1 Z a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pik - CatetiCT 104, fikpf ° -1 5 ((1.144/ Qtyoltkirt\ (te igmielor hpeozwet___ or Ot2655 1,14 undll Inspector: / I vU $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit (Loy-Zo PERMIT NO. f CITY OF TUKWILA BUILDING DIVISION Va- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: F p Type of Inspection: 2P0O , — Q°r49 14oT 'Ti cot". Address: �3 6 ` ie Date Called: - 6(- C4.f Fat tatAlt-72._ Fo'»J t4 — 14.o. 561t/ P11 SS( 400 i l}Nh 1 Special Instructions: Date Wanted: - �� t Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: — $DLX - 00- , — Q°r49 14oT 'Ti cot". Hower %is , CASethlkOff , SCGi116 lit Diet" Tly404 L octr r - 6(- C4.f Fat tatAlt-72._ Fo'»J t4 — 14.o. 561t/ P11 SS( 400 i l}Nh 1 - BoAl c 1. L 1 1504t5 Asr C idtAPP Inspector: 66init• Date: ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 1'1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: j. � � Type of Inspection: 7002 7D0, Address: � 3 Date Called: Special Instructions: Date Wanted: 1/�' a:m Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: nspector: Date: oliZr ro� LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: d _a w ten...:. • ..� - ��..� .... .e -_ INSPECTION NO. INSPECTION RECORDLJ,� Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION It. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36j70 Project: F y Type of Insp ,:in: —2 `o /7vj- Address: � �� D ate Call Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 'X 706 £ /L /A6 --)L /, /? 1/ -- 181)W. fLOK £Z(/ ZIPS _7_ ij , s Insl*L. &reAIi Dat7/ o a < ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: y._ INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -36'0 Project: r-: •` ,i_ /y r Type of II�Spe io Addres 236 S� /49G L. Date Called: 7 0 774/as - f cL M6 ,t411) X D Special Instructions: Date Wanted: a.m. p.m. Requester: f-lir./a f 9AJ/ z Phone No: LiApproved per applicable codes. '2orrections required prior to approval. COMMENTS: 700 2-, DGRolowEL4 C 7`_'o1 GuRIA c7;( 7 0 774/as - f cL M6 ,t411) X D :75), >~E'tvL (' /, T uNM: /445 Frail 6 E , -f CL LS -57-/al .l •trl6- (/ bL7h6E /9 ,)IN ?/7',i 1 coZ. S f('/ f-lir./a f 9AJ/ z C Insp f/ ' 4h'6 Date: 7/1 9 /0 C( $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit eLog-zDti PERMIT NO. CITY OF TUKWILA BUILDING DIVISION It 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: r‘i 6 Type of Inspection: 70o TA Address: 243(0 PtAtid Date Called: C6IL2' k cam , Special Instructions: Date Wanted: -thy 1!f m. Requester: Phone No: Approved per applicable codes. DCorrections required prior to approval. COMMENTS: TA b.c - 5 Deo C6IL2' k cam , Wilt- &502-4 itkov -or TAP LAI WTI AllA C-0 (PS Lc'O&6 Sort- T1i..L5, ow-r kit.. Inspector: 111 /36Abelec Date: O1 {t fOt $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .�..�.__�. • -- - -- - J1r.,..a.....A.1• _.a c.�s_- ...s.. • elm r. - L. . - i E lfih SA, "`b- 5+,.ats . INSPECTION RECORD Retain a copy with permit 64- 2'01 INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: F.Y 6 Type of Inspection: 700, Address:e� 6 Date Called: Special Instructions: Date Wanted: l j 11 rJ a m Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: 0-7/1/ (O1/4i n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project y ifc Type of Inspection: Add a s: ee. Date Called: Special Instructions: Date Wanted: �/ ", Vim., p. Requester: Phone No: roved per applicable codes. Corrections required prior to approval. OMMENTS: (K-- &eiW/GL 7 r f faALLA Inspe o ? j t it, i 4(Gl- Date: —7/316 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. .�. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431- Project: Type of Inspection: -7( Addres • , Date Called: 2 ' ''G • AWL pecial Instructions: Date Wanted: / a. . / d.r Requester: Phone No: Approved per applicable codes. ,Corrections required prior to approval. COMMENTS: fi, n (f;'4P-)/ 1,) f X:w I 4;'` , c- / , ( ,f it <% 5 //1) M/ ',v A Cifrviilc.--j r t iy /WN 4-VC fii,'z .4 /A%6 _ -c:-7A 6'L -- AO Mir- - -C, ' AA Lam/ c bi /4J alit - i72r. _\ .fir. /G r Approved per applicable codes. ,Corrections required prior to approval. COMMENTS: fi, n (f;'4P-)/ 1,) f X:w I 4;'` , c- / , ( ,f it <% 5 //1) M/ ',v A Cifrviilc.--j r t iy /WN 4-VC fii,'z .4 /A%6 _ -c:-7A 6'L -- AO Mir- - -C, ' AA Lam/ c bi /4J alit - i72r. _\ .fir. /G r ,/:5`&7,4fiiii61-/ Date: 7 it-7 /�� $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: two 3 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'f" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: F.Yi Type of Inspection: 76763 Addr4ss 6 6C /17 Date Called: Special Instructions: Date Wanted: Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. . OMMENTS:� trX--- C- //v( -- S /161/ L /IS 4-som 7— Inspe ;4 6/74/46,91/6/i Date:/ /,5 4 EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Ill 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 e Project: /4 yk r Type of Inspection: ... ....., j I� 6 „g Date Called: vi,,/( i vsS Special Instructions: Date Wanted: 6 !/ 5 mi Requester: Phone No: roved per applicable codes. Corrections required prior to approval. COMMENTS: Q/ 7 - ,NOT 4444ily 64 61,6:‹- — 0 - iiiiiiiL vi,,/( — e4ca( (*c i vsS Insp ildr (f;1u' / Date: //876k J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: t INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6teg_zoq PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le, 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: F--16 Type of Inspection: •n._ I 003 Address: i(9 3 67 `,i� Date Called: Special Instructions: Date Wanted: f3 a.m. Requester: Phone No: 0 Approved per applicable codes. Ei Corrections required prior to approval. COMMENTS: PA D • h _ — 54a5 LiI A-U;5 Inspector: 4NIAltik Date: 06/13 op El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG - I NT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address "' t •' f South Center Mall Date 2/21/2008 s For Building Department Use REVISED CODE COryp��MPLI CPR ®h E 6,_, t4„.... Seatt3,b, WA. 98188 Applicant Name: W.J. Sutherland & Associates Inc. Applicant Address: 6300 W old Shakopee Road Bloomington, MN. 55438 Applicant Phone: 952- 346 -4180 , FAX = 952- 346 -4181 Project Description [-New Building ❑ Addition ❑ Alteration ❑ Plans Incl', ded MAR 2 5 21 Refer to WSEC Section 1513 for controls and commissioning require ents. (w/ Option O Prescriptive 0 Lighting Power Allowance 0 Systems ^ a sil s' Tuk (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clean ony�la Cg `�� Alteration Exceptions (check appropriate box - sec. 1132.3) tl ❑ No changes are being made to the lighting �,s. ❑ Less than 60% of the fixtures new installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2"' Area in ft2 Allowed x Area 1st Floor Retail 1.50 3631.0 5446.5 Sales "D" 1 -50w MR16, 4" Downlight, Recessed Flood 3 50.0 150.0 Sales "01" 1 -70W PAR38, MB FL 15 70.0 1050.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 5446.5 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Sales "A" 3 -40w Fluorescent U-Tube 36 92.0 3312.0 Sales "D" 1 -50w MR16, 4" Downlight, Recessed Flood 3 50.0 150.0 Sales "01" 1 -70W PAR38, MB FL 15 70.0 1050.0 Toilet "F" 1 -100W Incandescent, Fan /Light Combo 1 100.0 100.0 Sales "PL" 2 -42W CFL, 9" Downlights, Recessed 2 94.0 188.0 Sales "N" 1 -50W, NEON 1 54.0 54.0 Stock /Corridor "SF" 2- F32T8, Surface Mount, 48" 7 58.0 406.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5260.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting. list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. HIE COSY NCE I) R�^ CITY or wr v.:•. '' MAR 0 3 2008 PERMIT CENTER toy 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary .(back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers 0 Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Liahtina Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions. museums, banks, churches)5'7'11 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments', restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia, assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference/exhibition hall" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies° (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. w. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit :Plans Checklist *LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address .,., South Center Mall Date 2/21/2008 The following information is necessary to check a permit application for compliance with the lighting, motor. and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations tl. a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features. indicate location n.a. (a) timer w /backup Indicate location n. a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n.a. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) yes I 1540 Transformers 'Indicate size and efficiency I I If "no" is circled for any question, provide explanation: PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -204 PROJECT NAME: FYE DATE: 03 -03 -08 SITE ADDRESS: 2636 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: F3uiPing ivision Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 17f Comments: Incomplete DUE DATE: 03-04-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04-01-08 Approved Approved with Conditions 1 r 1 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/rouung slip.doc 2 -28 -02 • City of Tukwila • 11 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Ft/ 6 — I:D {o J(, EL 1J7\T 1 aJ c" Project Address: I )'3 b S �� 0\1\ L - Contact Person: -JD L\ L Phone Number: Summary of Revision: —176- 11612.Arl f (_)■--3t-1\) 0'0 Project Name: REC 2 7 2008 t'EHMI I CENTEh Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: )] Entered in Permits Plus on (p(21'1J� \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Elect Electriin or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License NEALEI *022M9 Licensee Name NEAL ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602647877 Ind. Ins. Account Id Business Type CORPORATION Address 1 23036 NE 29TH ST Address 2 City SAMMAMISH County KING State WA Zip 98074 Phone 4254711653 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 7/29/1998 Expiration Date 9/19/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License NEAL *JC962DR Master Electrician Information License NEAL *JC962DR Name NEAL, JOEL C Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date NEAL, JOEL C 01/01/1980 • Bond Information Bond Bond I I I Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NEALEI *022M9 05/30/2008 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -204 Address: 2636 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/03/2008 Applicant: FYE Issue Date: Receipt No.: R08 -01876 Payment Amount: $393.60 Initials: JEM Payment Date: 05/30/2008 02:50 PM User ID: 1165 Balance: $0.00 Payee: NEAL ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 393.60 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 393.60 Total: $393.60 3037 05/30 9711 TOTAL 393.60 doc: Receiot -06 Printed: 05-30 -2008 J MUSIC Material Symbol Key 4b~ a MUM %W. [�C l + + + + + + + + ++ + + + + + + + ++ + + + + + + + + + + ACOUSTICAL CEILING CONCRETE BATT /LOOSE INSULATION STEEL FINISHED WOOD GYPSUM WALLBOARD BLOCKING /ROUGH LUMBER RIGID INSULATION PLYWOOD GLASS PARTICLE BOARD Symbol Key - CSI SPECIFICATION DIVISION NUMBER 5 ITEM, NOTE OR UNE NUMBER ELEVATION KEY NUMBER SHEET NUMBER DETAIL OR SECTION KEY NUMBER SHEET NUMBER - KEY TO WALL & FASCIA FINISH SCHEDULE EY TO FLOOR FINISH SCHEDULE Ca 7. KEY TO CEILING & SOFFIT FINISH SCHEDULE KEY TO WALLS AND PARTITION SCHEDULE Fire Ratings CARPET MIWKEN MODULAR — TONAL VISTAS CLASS "1" RATING CRITICAL RADIANT FLUX— ASTM TEST E -648 : >0.45 W/CM2 OPTICAL DENSITY OF SMOKE— ASTM TEST E -662 : <450 FLAMING WALL PARTITIONS SALES TO STOCKROOM: NEW NON—RATED PARTITION TENANT TO TENANT: 1 HOUR RATED PARTITION TO ABOVE CEILING; PER UL #U -465 TENANT TO SERVICE CORRIDOR: 1 HOUR RATED PARTITION TO DECK; PER UL 1 -465 CEILING SYSTEM CEIUNG SYSTEM: CLASS "A" FINISHES SLAT WALL: CLASS "C" PLASTIC LAMINATE: CLASS "C" MOUNTED TO CLASS "A" VINYL COMPOSITE 11LE: CLASS "1" VINYL COVE BASE: CLASS "1" FLOOR TILE CLASS "1" Copyright These drawings shall remain the exclusive property of THE ARCHITECT and its Consultants. All rights and privileges are reserved by the design team. The designer's liability is limited to the extent of their fee. These drawings shall not be duplicated without prior written permission of The Architect. Schedule of drawings T -1 T-2 TITLE SHEET EGRESS PLAN A -1 ARCHITECTURAL FLOOR PLAN / PARTITION &DOOR SCHEDULES A -1.1 STOREFRONT ASSEMBLY / MISC. DETAILS A -1.2 STOREFRONT ELEVATION / FLOORING PLAN A -2 INTERIOR ELEVATIONS / FINISH SCHEDULES A -3 REFLECTED CEILING PLAN / LIGHT FIXTURE SCHEDULE MISCELLANEOUS DETAILS FIXTURE PLAN NOTES AND SPECIFICATIONS A -4 F -1 N-1 P-1 M-1 M -2 M -3 E -1 E -2 E -3 PLUMBING PLAN AND SPECIFICATIONS MECHANICAL PLAN SPRINKLER PLAN MECHANICAL SPECIFICATIONS ELECTRICAL LIGHTING PLAN ELECTRICAL POWER PLAN ELECTRICAL SPECIFICATIONS & SCHEDULES Store Data (FOR STORE USE ONLY) AREA DISTRIBUTION PLAN DESIGNATION QUANTITY PERCENTAGE OF AREA 1. GROSS LEASED AREA 3,631 S.F. 100.0 % 2. SALES AREA 3,142 S.F. 86.5 % 3. STOCKROOM 345 S.F. 9.5 % 4. TOILET ROOM 62 S.F. 1.7 % 5. EGRESS CORRIDOR 82 S.F. 2.3 % APPROVED P! io..r 77 :: :.ANGED, MODIFIED OR ALTERED • ,,..f. WITHOUT AUTHORIZATION FROM THE BIPLONG Or, "IC :AL, ALL WORK SHALL BE DCNE IN ACCORDANCE WITH T lE APPROVIB3 PLANS AND ISL `"TTOF,E''D' --'�'��•• • .NaPL TIOP :a Key Plan MOVIES N.T.S. NORDSTROM MACY'S SEARS I_ J REVIEWEP�CE CODE 70 - NEC NFPA SCOPE OF WORK: THIS PROJECT IS A NON— STRUCTURAL TENANT FIT UP OF AN NEW SPACE WITHIN WESTFIELD SOUTH CENTER. WORK SHALL INCLUDE THE CONSTRUCTION OF NEW INTERIOR PARTITIONS, DOORS, CEILINGS, LIGH11NG, AND THE INSTALLATION OF ALL RELATED FIXTURES AND FINISHES. NEW HVAC SYSTEM AND ACCESSIBLE TOILET ROOM ARE REQUIRED. SEE DRAWINGS FOR ADDITIONAL INFORMATION. ALL WORK SHALL COMPLY WITH THE APPLICABLE CODES AS NOTED ON THIS DRAWING. Project. .Information BUILDING DEPARTMENT: City of Tukwila Department of Community Development Contact: Dave Larson Phone: (206) 431 -3678 6300 South Center Blvd #100 Fax: (206) 431 -3665 Tukwila, WA 98188 APPLICABLE AND MODEL CODES: International Building Code 2006* National Electrical Code 2005* International Mechanical Code 2006* Uniform Plumbing Code 2006 International Fire Code 2006* ANSI -117 -1 2003* ADA Guidelines * with the WA State Building Codes Amendments And all accumulative supplements thereof WA State Energy Code CODE ANALYSIS: USE GROUP: CONSTRUCTION TYPE: SEISMIC ZONE: FIRE SUPPRESSION: LIVE LOAD: M — MERCANTILE 2B UNPROTECTED,NON — COMBUSTIBLE, CLASS D AUTOMATIC SPRINKLER SYSTEM 100 PSF MEANS OF EGRESS /OCCUPANCY LOAD SEE SHEET T -2 FOR ADDITIONAL INFORMATION NOTE: SPRINKLER AND FIRE ALARM WORK TO BE PERFORMED UNDER SEPARATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPARATELY. NOTE: MAXIMUM NUMBER OF EMPLOYEES ON SITE AT ANY ONE TIME IS 4. SPACE IS LOCATED WITHIN 300 FT OF PUBLIC ACCESSIBLE RESTROOMS. f.y.e. SPACE # 2110 LEVEL 2 OF 3 3,631 SQ. FT. FILE -QPY Permit No. jo Plar review approval Is abject to errors and on1 Approval of construction documents does not auU the violation of any adopted code or ordinance. R of approved Field py and cordtions is awl± By Dal sp„ jai FULLY City of Tukwila BUILDING DIVISION REVISIONS Pb changes shall be made to the scope of work without prior approval of Tukwila Building Division NOTE: Revisions will require ? new pion suhrni ?'11 and rra.' n1P. "1 SPRINKLERED ' SEPARATE P REP MIT REQUIRED FOR: eMechardcal ❑rElechical I� Plumping itr Gas Piping I City of Tukwila 3UfLDING DIVISION Southcenter Mall Space # 2110 2636 Southcenter Mall Seattle, : A 98188 Key to Divisions of Work FURNISHED I INSTALLED CSI C CSI o SHEET ° DESCRIP11ON /NOTES n a & ~1-OM1 - CC ° ¢ ¢ u Qa 1- 0 00 CONTRACT REQUIREMENTS 1 Bonds(if required) 0 00600 T T -1 P Payment /Performance Bond shall • • 2 Insurance 0 00650 T T -1 P Provide Certificates • • 01 GENERAL 1 Permits and Fees 0 01000 T T -1 P Per Scope of Work • • 2 Inspections 0 01000 T T -1 C Comply with Local Procedures • • 3 Barricade 0 01100 T T -1 I If Required • • 0 0 4 Temporary Electrical 0 01500 T T -1 I If Required to Finish Work • • 0 0 5 Temporary Telephone 0 01510 T T -1 I If Required • • 0 0 02 SITE WORK 1 Selective Demolition 0 02070 A A -1 F For Rear Egress Door 0 0 0 0 03 CONCRETE 1 Concrete slab A A -1 0 0 2 Reserved 04 MASONRY, . . 1 Reserved 05 METALS 1 Misc. Metals 0 05000 A A -1 S See Technical Specification on N -1 0 0 0 0 2 Light Gauge Framing 0 05400 A A1,N1 S See Partition Schedule Sheet A -1 0 0 0 0 0 0 3 Metal Furring Channels 0 05000 A A -1 I If Required 0 0 0 0 4 3/4'x3/4" Wall Angle 0 05000 A A -2 S Slatwall Trim,See Detail Sheet A -4 0 0 0 0 5 1 "x1" Wall Angle 0 05000 A A -1 S Sales Area Columns 0 0 0 0 6 Metal U— Channel 0 05000 A A -1.1 S Storefront 0 0 0 0 06 WOCO AND PLASTICS 1 Rough Carpentry 0 06100 A A -1 S See Technical Specification on N -1 • • 0 0 2 Finish Carpentry 0 06200 A A -1 S See Technical Specification on N -1 0 0 3 Toggle Bolts 0 06200 A A -1 S See Technical Specification on N -1 • • 4 Misc. Wood Trim 0 06220 A A -2 • •• 0 0 1/A 5 Particle Board Valance 0 06220 6 Plastic Laminate 0 06240 A A2,F1 1 1 Fixtures • • 0 0 0 0 7 Hardboard Panels 0 06255 A A-2 P Prefinished 0 0 0 01 (Slatwall) 07 THERMAL/MOISTURE 1 00 40 00 O! Contract Requirements 00002 — PROJECT DIRECTORY LANDLORD'S REPRESENTATIVE: Westfield Corporation Inc. Contact: Josh Kimmel 11601 Wilshire Blvd 12th Floor Los Angeles, CA 90025 TENANT: Trans World Entertainment Corp. Contact: Allison Rivers 38 Corporate Circle Albany, NY 12203 Phone: (310) 893 -4761 FAX: (310) 575 -5991 Phone: (518) 452 - -1242, Ext. 7489 FAX: (518) 452 -0511 TENANT'S COORDINATOR: Bay Planning Company, Inc. Contact David M. Sorgman 25 Mathewson Drive, Suite 200 Weymouth, MA 02189 Phone: (781) 331 -4000 FAX: (781) 335 -2115 SUBCONTRACTOR: Subcontractors are those individuals and /or Companies providing services, products and portions of the Work, described in the technical drawings and specifications, under direct contract to the Tenant's Contractor. Requirements 01000 — GENERAL �./ The Tenant's Contractor and all Subcontractors shall perform their Work according to the following: EXISTING CONDITIONS A. Prior to submitting bid proposals, the Tenant's Contractor and each Subcontractor shall visit the proposed space and make themselves familiar with all existing conditions, take field measurements and record all information needed to provide a complete scope of Work. B. Notify the Tenant immediately of conditions which may contribute to unnecessary, excessive costs. C. No additional compensation will be paid by the Tenant for disputes which result from a lack of familiarity with the existing conditions. 01035 — MODIFICATION PROCEDURES SUBSTITUTIONS & CHANGES D. DO NOT substitute materials, equipment or methods unless such substitution has been approved specifically in writing by the Tenant. E. Notify the Tenant immediately by telephone of any hidden, unforeseen conditions and any requirements imposed by the Landlord which impact the Work. Confirm all notifications and action required in writing within 24 hours of the event. F. Milestone date changes must be made in writing by Tenant. 01040 — COORDINATION G. The Tenant's Contractor and each Subcontractor shall be thoroughly familiar with the Work shown on the drawings and on the other Contract Documents. H. Each Subcontractor shall coordinate their Work with that of others and be aware of all Related Work to be performed by others, via the Tenant's Contractor. 01060 -- REGULATORY REQUIREMENTS 1. Comply with all applicable National, State and Local codes. See Project Information on this sheet. 01100 — SPECIAL REQUIREMENTS J. NEW STORE CONSTRUCTION K. WRITTEN DAILY JOURNAL shall be maintained L TELEPHONE shall be provided on site by Tenant's Contractor. M. DESIGNATE A SUPERINTENDENT for the duration of the Project and submit his /her name to the Tenant. N. Work shall be completed in a timely manner, consistent with the approved CONSTRUCTION SCHEDULE. P. The Tenant's Contractor shall be responsible for receiving and maintaining in good condition all millwork, fixtures and equipment up to the Date of Substantial Completion. Q. All Tenant material delivered to the Project shall be checked against the Tenant's material list by the Tenant's Contractor at the time of delivery. All discrepancies shall be noted in the Receiving Report and in the Daily Journal, and the Tenant's Contractor shall immediately notify the Tenant of same. All Shortages occurring after receipt of goods shall be charged back to the Tenant's Contractor. R. CLEA N I N G: a. Each Subcontractor shall clean his /her Work and remove all trash, debris, packing, etc... resulting from that Work. b. Final cleaning shall be done by a professional cleaner. See specification section 01710 — FINAL CLEANING 01340 — SUBMITTALS S. Product samples, manufacturer's data and shop drawings shall be submitted to Comprehensive Development Corp. for review prior to fabrication or start of work. 01700 -- CONTRACT CLOSE —OUT T. Substantial Completion is the date certified by Tenant's Project Manager on which the Work or designated portion thereof is sufficiently complete so the Tenant may occupy the same for the intended purpose. U. Provide the following for close—out 1—Daily Journal 2— Operation and Maintenance Data 3 —Keys 4 —Spare Parts, Materials and Stock 5— Certificate of Inspection /Occupancy 6— Certificate of Insurance 7— Evidence of Payrnent and Release of Liens 8 —List of Subcontractors, Vendors and Suppliers Works, aiming Division 9 —Final Statement of Account ert PERMIT NUMBER V. Construction codes and keys must be turned into TWEC with the General Contractor's final payment request or the contractor will be charged $70. R"" CITY or i ur,vr.w MAP 0 3 2008 PERMIT CENTER NOTE: T.G.C. TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION AND INFORM THE TENANT'S PROJECT MANAGER AND THE ARCHITECT OF ANY DISCREPANCIES IMMEDIATELY. NOTE: T.G.C. TO FIELD VERIFY CONDITION OF ALL ITEMS DESIGNATED TO REMAIN OR BE REUSED AND INFORM TENANT'S PROJECT MANAGER AT THE START OF CONSTRUCTION OF ANY ITEMS IN NEED OF REPAIR. REVISIONS: DATE: 2/20108 JOB NO: PY- 06 -01 -D STORE NO: 124 TWEC PR #: 28°x11 CHECKED: CM LLI LLJ CI) LjJ J PROJECT COORDINATION: Fax: 781 -535 -2115 SHEET NUMBER T -1 SHEET 1 OF 17 ' B SF A HA -5 A HA -5 A HA -5 LA -11 U MN I MEI F LA -11 Y HA -9 HA -9 E HA -9 0® E HA-9 SF--- HA-9 01• Y HA 9 SF HA -9 Y� HA -9 A HA -5 A HA -5 EM ®HA-1 A HA -5 A HA -5 A HA -5 ®HA-1 II EM ''HA -1 N/L A HA -3 A HA -3 A HA -3 A HA -1 A HA -3 A HA -3 HA A -3 A HA -3 N/L HA-1 EM 1 ®H 1 H II E J1 N/L A HA -5 A HA -1 A HA -5 • N/L A HA -5 A HA -5 A HA -1 A HA -5 A HA -5 • EM ® HA -1 ® EM Hit-1 EM ® HA -1 Asa D1 LA -5 HAr5 0 D1 LA -9 0 D1 LA -5 A HA -3 A HA -3 A HA -3 A HA- I A HA -3 A HA -3 VERIFY ALL EXISTING CONDITIONS IN THE FIELD. MARK NOTE; THE ELECTRICAL CONTRACTOR SHALL PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITING INDICATED. COIL V NOTE; THE LOCAL BUILDING DEPARTMENT REQUIRES A MINIMUM OF ONE FOOT CANDLE OF EMERGENCY LIGHTING THROUGHOUT THE ENTIRE TENANT SPACE. AMP DEMOLITION; THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, LIGHT FIXTURES, DEVICES, CONDUIT AND WIRE, ETC.. NOT BEING REUSED. STOREFRONT SIGN & UGHTS ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE WITH THE LANDLORD'S MECHANICAL /ELECTRICAL CRITERIA. ALL CONTRACTORS SHALL OBTAIN A COPY OF THE CRITERIA FROM THE LANDLORD'S TENANT COORDINATOR, OR MALL OPERATIONS MANAGER AND BECOME FAMILIAR WITH THE REQUIREMENTS CONTAINED WITHIN PRIOR TO BIDDING THE JOB. WHERE LANDLORD'S REQUIREMENTS CONFLICT WITH CODES OR ORDINANCES THE STRICT .S1 INTERPRETATION SHALL APPLY. EXIT AND EMERGENCY LIGHTING SHALL BE PER REQUIREMENTS OF LOCAL GOVERNING CODES. BATTERY PACKS FOR EXIT AND EMERGENCY LIGHTS MUST BE REMOTE OR RECESSED. PAINT EXPOSED SURFACES TO MATCH ADJACENT FINISH. NOTE; FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. NOTE; ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANTS VENDOR. A HA -3 A HA -3 A HAI3 J -BOX FOR NEON LIGHTING ON CIRCUIT LA -3, VIA TS1. MOUNT NEON TRANSFORMER AS REQUIRED. D1 0 LA -9 D1 0 LA-5 O D1 L4 -5 0 D1 LA -9 0 D1 LA -5 EM HA -1 D1 0 LA -9 EM HA--1 ED O D1 LA -5 HA-�3 L D1 LA -9 VOLTARC SPARKLING BLUE NEON ACCENT STRIP W /NATURAL ALUMINUM PANEL ON FACE OF SOFFIT, FURNISHED AND INSTALLED BY TENANTS SIGN CONTRACTOR. SEE DETAIL 2/A1.1 FOR ADDITIONAL INFORMATION. a D1 LA -5 0 D1 LA -9 0 D1 LA -5 O D1 0 I 0 0 II LA -9 LIGHTING PLAN 0 1 2 4 CONTACTOR SCHEDULE MARK LOAD CONTROL COIL V UNE V POLES AMP CIRCUITS C1 STOREFRONT SIGN & UGHTS TS1 120 120 8 20 LA- 113,10,12 C2 SALES LTG MC1 120 120/277 4 20 HA -3 LA -5 C3 SALES LTG MC2 120 120/277 4 20 HA -5 LA -9 LA-34 NEUTRAL HOT TIME SWITCH (TS1) C1 • SEE CONTACTOR SCHEDULE FOR ADDITIONAL INFORMATION. MC1 MC2 CONTACTOR CONTROL DETAIL NOT TO SCALE C2 r -- STOREFRONT UGHTS SIGN & SHOW. WINDOW REC. SALES AREA LIGHTS SALES AREA LIGHTS 1 /4" = 1 -0" 8 FEET J -BOX FOR NEON LIGHTING ON CIRCUIT LA -3, VIA TS1. MOUNT NEON TRANSFORMER AS REQUIRED. LIGHTING PLAN KEY NOTES ® 1. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT. 2. CIRCUIT EXHAUST FAN /LIGHT COMBINATION AS INDICATED. FAN AND LIGHT SHALL BE CONTROLLED BY THE SAME SWITCH. 3. INSTALL WATT STOPPER #WS -120 -W OCCUPANCY SENSOR. SENSOR SHALL BE FURNISHED BY LIGHTING VENDOR. MAKE FINAL CONNECTIONS. 4. INSTALL WATT STOPPER #C1 -200 CEILING MOUNTED OCCUPANCY SENSOR. SENSOR SHALL BE FURNISHED BY LIGHTING VENDOR. MAKE FINAL CONNECTIONS. 5. INSTALL WATT STOPPER POWER PACK. POWER PACK SHALL BE FURNISHED BY LIGHTING VENDOR. MOUNT ON WALL ABOVE CEILING IN AN ACCESSIBLE LOCATION. PROVIDE ALL NECESSARY ITEMS FOR A FULLY FUNCTIONING SYSTEM. 6. PROVIDE 11MESWITCH: PARAGON MODEL 7000 SERIES OR EQUAL WITH 7 DAY 24 HOUR SCHEDULE FORMAT, MIN. (4) N.O. 20 AMP 120/277 VOLT CONTACTS 120 VOLT COIL AND SPRING WOUND RIDE THROUGH SWITCH TO CONTROL STORE FRONT SIGN AND LIGHTING OR CONTACTORS AS INDICATED. 7. PROVIDE LIGHTING CONTACTOR(S): ASCO 917 SERIES OR EQUAL WITH 120 VOLT COIL MINIMUM 20 AMP 120/277 VOLT CONTACTS ELECTRICALLY OPERATED AND MECHANICALLY HELD, 3 -WIRE CONTROL SEE CONTACTOR SCHEDULE FOR ADDITIONAL INFORMATION. CONTACTOR(S) CONTROLLED VIA TIMESWITCH AND /OR MOMENTARY CONTACT SWITCH AS INDICATED. SEE CONTACTOR CONTROL DETAIL 2/E-1. 8. EMERGENCY LIGHTING AND EXIT SIGN SHALL BE WIRED AHEAD OF SWITCHING DEVICE. 9. CENTER TYPE "D1" LIGHT FIXTURES BETWEEN GLAZING CHANNEL AND GYPSUM BOARD SOFFIT. 10. EXIT SIGN TO BE MOUNTED, CENTERED ABOVE DOOR AT 7' -6" AFF TO CENTERLINE OF FIXTURE. 11. EXIT SIGN TO BE MOUNTED ON FACE OF SOFFIT SO AS NOT TO BE VISIBLE FROM MALL COMMON AREA. 12. MASTER SWITCH LOCATION: PROVIDE (2) MASTER SWITCHES FOR CONTROL OF CONTACTORS. SEE CONTACTOR SHEDULE ON THIS SHEET. MOUNT ON WALL BEHIND CASHWRAP. VERIFY EXACT LOCATION WITH ARCHITECT. NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge PL LA -1 PL LA -1 LA D -1 9 LA D -1 0 LA -1 VOLTARC SPARKING BLUE NEON ACCENT STRIP W /NATURAL ALUMINUM PANEL ON FACE OF SOFFIT, FURNISHED AND INSTALLED BY TENANT'S SIGN CONTRACTOR. SEE DETAIL 2/A1.1 FOR ADDITIONAL INFORMATION. CEILING MOUNTED LIGHT FIXTURES SYMBOL DESCRIPTION MFR. STYLE/ CAT. NO. VOLTS/ LAMPS COMMENTS N/A N/A Fluorescent Light Fixture w/ 9 Cell White Parabolic Lens Surface Mounted Single Circuit Track System (Silver) Incandescent Gimbal Ring Open Back MonopointTrack Head (Silver) 4" Recessed Incandescent Downlight 8" Recessed Incandescent Downlight Exit Light Fixture with 90 Minute Battery Backup Recessed Emergenc g with 90 MinuLite ht Battery Backup Combination Fan / Light 100 CFM 9" Recessed Compact Fluor. Downlight 4' Fluorescent Strip Fixture Surface Mounted Emergency Light with 90 Minute Battery Backup Designates Night —light LIGHTOLIER JUNO JUNO JUNO JUNO ATUTE DUAL —UTE NUTONE JUNO SIMKAR ATIJTE PLA2G9WP 3FT277X3 T2NA, T4NA, T6NA, T8NA V689NA TC44/ 447CWH MC8P3870/ 8838CWH PNLRU E2-2R 8663P CH9 226/ 32/42T— 950CWH CH -232 PCI -10 3 PLL40 /35K 77 Volts 3) U -40W 120 Volts 120 Volts 75W PAR 30 NFL 120 Volts 50W MR16 FL EXN 120 Volts 70W PAR38 MH FL 277 Volts (2) 15T6 12W 277 Volts 8W 120 Volts 1 -100W 120 Volts (2) 42W 35K 277 Volts 2 —F32T8 TL735 120/277 V 8W Sales Area See Note 1 Below Sales Area (Storefront Soffit) Sales Area Soles Area Stockroom Egress Corridor Sales Area Toilet Room Storefront Soffit Stockroom Egress Corridor Stockroom, Toilet Room Egress Corridor ril2'x2' •• LIC1 OD Oi, 0 Si E EM F ■ ■ 0PL SSF Y d NOTE 1: ALL FLUORESCENT LAMPS SHALL BE CHROMA 30 (UNLESS OTHERWISE NOTED). NOTE 2 T.G.C. TO FIELD VERIFY EXACT LOCATION & POSITIONING OF TRACK HEADS WITH TENANTS PROJECT MANAGER PRIOR TO INSTALLATION. NOTE 3: NEON LIGHTING IS TO BE 13mm DOMESTIC GLASS CUSTOM FIT. FABRICATOR TO PROVIDE SHOP DRAWINGS OF THE PROPOSED NEON LIGHTING, SHOWING LIGHT FIXTURES, MOUNTING AND TRANSFORMERS FOR APPROVAL LOCATE TRANSFORMERS ABOVE CEILING IN AN ACCESSIBLE LOCATION. NEON COLORS TO BE AS DESIGNATED ON CEIUNG PLAN. ALL HOUSINGS TO BE RECESSED BEHIND SOFFIT WALL OR ABOVE CEILING. SEE DETAILS FOR MOUNTING LOCATION OF NEON. NOTE; SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF LIGHT FIXTURES. IF DISCREPANCIES EXIST BETWEEN THIS SHEET AND ARCHITECTURAL REFLECTED CEILING PLAN, ARCHITECTURAL REFLECTED CEILING PLAN WILL TAKE PRECEDENCE. DATE: 2/20/08 n O Z m O STORE NO: 1248 U m DRAWN BY: CHECKED BY: E 0 U w C °c O '. *l 2+ Cn . §Vn o .0 to ▪ m W 0 P.- CITY:31- 1 Una v.. MAP 032008 PERMIT CENTE SHEET NUMBER E -1 SHEET 15 OF 17 INSTALL AT P.O.S. CABINET. 0 UNE #2 4-28 IG 0 V CP) LA- 14 LA-14 LA 18" 1 LA-16 LA-30 \ FOLDING TABLE VAV-1 "C. / (2)1"C. RJ11- -RJ14 - RJ45 7 o i LA-15 i LA-15 LA-15 LA-14 LA 32 NAME VOLT/ PHASE 9ff CON DUIT/ WIRE CONTROL STARTER PNL CCT. NO. DISC. SWITCH FUSE SIZE NOTES HP KW VAV-1 00 0 - LA-14 LA-14 LA-14 LVS UNIT (TYP.) 00 41) -64 LA-32 3:( LA46 oo LA46 LA68 00 LA48 LA- 8 11102> 1 LA-14- U. LJir 17 1 11110Imm • im • im El is • num mammo is am 116 LA-_l8 I mg • im-a-a7s-rlogrio, LA-18 NOTE: TENANT E.C. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. NOT; FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. EEL ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. EQUIPMENT SCHEDULE i NAME VOLT/ PHASE LOAD CON DUIT/ WIRE CONTROL STARTER PNL CCT. NO. 00 LA48 LA- 8 11102> 1 LA-14- U. LJir 17 1 11110Imm • im • im El is • num mammo is am 116 LA-_l8 I mg • im-a-a7s-rlogrio, LA-18 NOTE: TENANT E.C. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. NOT; FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. EEL ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. EQUIPMENT SCHEDULE NO. NAME VOLT/ PHASE LOAD CON DUIT/ WIRE CONTROL STARTER PNL CCT. NO. DISC. SWITCH FUSE SIZE NOTES HP KW VAV-1 VAV BOX #1 277/480/3 1/3 5.0 3/4C.-4#12 CU. DIV.15 DIVA 5 HA 8,10,12 30A/3P 15 SEE KEYNOTE VAV-2 VAV BOX #2 277/480/3 1/3 5.0 3/4C.-412 CU. DIVA 5 DIV.15 HA 14,16,18 30A/3P 15 SEE KEYNOTE WH-1 WATER HEATER #1 120/1 -- 1.7 3/4"C-2#12 - CU DIV. 15 - LA 13 - - SEE KEYNOTE TYPE fr FAN/UGHT COMBO. 120/1 -- 0.2 3/4"C-2#12 - CU WALL SW. -- LA 11 -- - SEE KEYNOTE ON SHEET El POWER PLAN KEY NOTES 0. 1. PROVIDE TELEPHONE BACKBOARD AS SPECIRED. 2. PROVIDE TELEPHONE OUTLET, CONDUIT AND CABLE. SEE DETAIL 3/E-3. 3. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT. 4. NOT USED. 5. ALL CONDUIT AND WIRING AT CASHWRAP SHALL BE CONCEALED IN CASEWORK. COORDINATE WITH CASEWORK MANUFACTURER. 6. PROVIDE J - BOX WITH DISCONNECT SWITCH IN ACCESSIBLE CONCEALED SPACE FOR STOREFRONT SIGN. FIELD VERIFY EXACT LOCATION. SEE SPECIFICATION ON SHEET E-3 FOR ADDITIONAL INFORMATION. 7. PROVIDE FLUSH DUPLEX RECEPTACLE IN SHOW WINDOW CEIUNG. COLOR SHALL MATCH ADJACENT SURFACE. 8. ISOLATED GROUND CIRCUITS SHALL BE INSTALLED IN SEPARATE CONDUIT FROM NORMAL POWER CIRCUITS. EACH IG CIRCUIT SHALL HAVE A. SEPARATE NEUTRAL AND INSULATED GROUND WIRE. THE GROUND WIRE SHALL BE CONTINUOUS BACK TO THE PANEL AND CONNECTED TO THE GROUND BUS WITHIN THE PANEL IG RECEPTACLES SHALL BE HUBBELL NO. IG-5362, OR APPROVED EQUAL. 9. CORE BORE FLOOR SLAB AND INSTALL CONDUIT WITH PULLWIRE. PROVIDE BUSHING AT EACH END. PATCH AND REPAIR FLOOR TO MATCH EXISTING CONDMON. COORDINATE WORK WITH MALL OPERATIONS MANAGER. 10. SEE EQUIPMENT SCHEDULE FOR MECHANICAL EQUIPMENT INFORMATION. COORDINATE EXACT LOCATION WITH MECHANICAL CONTRACTOR. 11. PROVIDE A 1 1/2" CONDUIT FOR DATA UNES FROM CASHWRAP. COORDINATE WITH TENANT'S PROJECT MANAGER. 12. PROVIDE DEVICES SHOWN IN BACKROOM. COORDINATE WITH TENANT'S PROJECT MANAGER. 13. PROVIDE A DUPLEX RECEPTACLE AND LOW VOLTAGE JUNCTION WITH 1 C. WITH PULL STRING, STUB UP ABOVE CEIUING IN ACCESSIBLE LOCATION. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. 14. NOT USED. 15. PROVIDE 120 VOLT CONNECTION TO SENSORMATIC SYSTEM. COORDINATE EXACT REQUIREMENTS WITH TENANT'S PROJECT MANAGER. 16. NOT USED. 17. NOT USED. 18. PROVIDE DEVICE IN CEIUNG FOR LOSS PREVENTION REQUIREMENT. COORDINATE WITH TENANT'S PROJECT MANAGER. 19. ALL CONDUITS ROUTED TO FLOOR FIXTURES SHALL BE STUBBED UP AT O'-4 AFF. INSTALL BUSHING AT TOP AND PROVIDE PULL STRING.. 20. TENANT'S A/V VENDOR SHALL FURNISH AND INSTALL CEIUNG MOUNTED SPEAKERS AND RELATED WIRING AS INDICATED ON PLAN. COORDINATE WITH TENANT'S PROJECT MANAGER. 21. PROVIDE SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340-405-24VAC BUZZER, ONE (1) NEW ANNUNCIATOR LOCATED AT THE CASHWRAP AND ONE (1) BUZZER IN THE OFFICE, 852 WEATHERPROOF PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT UNLESS REQUIRED BY LANDLORD OR LOCAL AUTHORITY. 22. RECEPTACLES IN THE SALES AREA SHALL BE LOCATED 12'-0" ON CENTER. FIELD VERIFY EXACT LOCATION. 23. NOT USED. 24. PROVIDE FLUSH MOUNTED J -BOX AT 181. AFF AT LVS STATION IN BACKROOM. J -BOX SHALL HAVE (2) 1" CONDUITS STUBBED UP ABOVE CEIUNG TO ACCOMODATE LOW VOLTAGE WIRING FROM SALES AREA LVS STATION(S). COORDINATE WITH TENANT PROJECT MANAGER. 25. NOT USED. 26. NOT USED. 27. ELECTRICAL CONTRACTOR SHALL PROVIDE A 3/4" CONDUIT WITH PULLSTRING STUBBED UP ABOVE CEIUNG FOR LVS WIRING BY TENANT. CONDUIT SHALL BE CUT FLUSH TO FACE OF WALL AT 18" A.F.F., AND NIPPLE SHALL BE INSTALLED. 28. PROVIDE RECEPTACLE AND UGHT SWITCH AT VAV BOX UNITS. PROVIDE PORCELAIN SOCKET WITH (1) 60WA19 LAMP, MOUNT NEAR ACCESS PANEL VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR. POWER PLAN .22 H l 4 8 FEET 1 /4" ALL CONDUITS AND CABLE PROVIDED BY ELECTRICAL CONTRACTOR. NOTE: ALL CONDUITS TO RUN WITHIN FIXTURE FROM DEMISING WALL ADJACENT TO CASHWRAP. SLAB CORE BORING NOT REQUIRED. NOT SEE FLOOR PLAN FOR CORRECT ORIENT TION. NOTE: VERIFY CASH WRAP ELECTRICAL REQUIREMENTS WITH TENANT PROJECT MANAGER. 1 1/2" CONDUIT WITH PULLSTRING FROM POS CABINET WITHIN STOCKROOM FOR DATA UNE. TENANT'S VENDOR TO PULL DATA CABLE. 3/4* CONDUIT WITH PULLSTRING FOR TELEPHONE SYSTEM. EXTEND TO TELEPHONE BACKBORAD IN STOCKROOM. DEDICATED DUPLEX OUTLET IN AN ACCESSIBLE LOCATION FOR FUTURE LOSS PREVENTION. (1) 1 1/2" CONDUIT WITH PULLSTRING FOR A/V EQUIPMENT. RUN WITHIN MILLWORK AND STUB ABOVE CEIUNG TO AN ACCESSIBLE LOCATION. BUSH TOP END. vi LA-8 41,1-A-8 (2) 3/4" CONDUIT AT CASHWRAP AND PAN ELBOAR D: (1) CONDUIT FOR IG RECEPTACLES CLEAN POWER AND (1) CONDUIT FOR RECEPTACLES DIRTY POWER. RUN CONDUIT WITHIN MILLWORK OF CASHWRAP. IG UNES #1 AND 2 FOR TELEPHONE UNES 2 UNE RJ -141 TELEPHONE JACK. RJ-45 TELEPHONE JACK FOR DATA UN ES ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX IN CASH WRAP FOR ALTRONIX ALTV248 CAMERA POWER SUPPLY UNIT. COORDINATE NUMBER AND LOCATION OF CAMERAS WITH TENANT'S PROJECT MANAGER ELDS 00-2.014 CASH WRAP POWER PLAN CITY 01 I ur,v... MAP 0 3 NM PERMIT CENTER ■11.11110/ t.) C.* ■74 0 z 0 STORE NO: C.) C.) CO DRAWN BY: CHECKED BY: PROJECT COORDINATION: . . • 111 ..\••■•\ 1••••■•■•■\NNV:W.• RI 1M &tem 1-111•1 • SHEET NUMBER E-2 SHEET 16 OF 17 H ELECTRICAL SPECIFICATIONS 16000 - GENERAL PROVISIONS 0.01 PERFORMANCE: ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANUKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE TRADE. 0.02 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIMS FOR EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS SHALL NOT BE ALLOWED OR APPROVED. 0.03 JOB SITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. 0.04 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.05 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSER, BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.06 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.07 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL AND MECHANICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH OTHER TRADES. 0.08 ROOF PENETRATIONS: COORDINATE WITH LANDLORD. 0.09 MECHANICAL SUBSTITUTIONS: INVOICE MECHANICAL CONTRACTOR, NOT TENANT, FOR COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.10 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.11 REFERENCE STANDARDS: COMPLY WITH NEC, AND APPUCABLE STANDARDS OF NFPA, ANSI, NEMA, AND UL, EXCEPT AS SUPERSEDED BY LOCAL AUTHORITY-. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 0.12 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF LOCAL CODES, LANDLORD, SERVING UTILITY, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.13 SCHEDULE: ORDER EQUIPMENT WITHIN 5 DAYS OF RECEIPT OF CONTRACT TO MAINTAIN CONSTRUCTION SCHEDULE. 0.14 TEMPORARIES: PROVIDE ALL TEMPORARY SERVICE, UGHTING AND POWER FOR ALL TRADES AS REQUIRED. REMOVE ALL TEMPORARIES BY THE TIME OF PROJECT COMPLETION. 0.15 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL LISTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPLIANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. COMPLY WITH CURRENT CODES. 0.16 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' RECOMMENDATIONS. 0.17 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT. VERIFY PROPER MOTOR ROTATION OF ALL EQUIPMENT. 0.18 0 & M MANUALS: AT COMPLETION OF PROJECT, PROVIDE TO TENANT ALL OPERATING AND MAINTENANCE MANUALS AND INFORMATION FOR MATERIAL EQUIPMENT AND SYSTEMS INSTALLED UNDER THIS CONTRACT. 0.19 CORRECTIVE PERIOD: PROVIDE A CORRECTIVE PERIOD FROM DATE OF FINAL ACCEPTANCE OF NOT LESS THAN ONE (1) YEAR FOR THE ENTIRE INSTALLATION, DURING WHICH PERIOD UNCONDITIONALLY MAKE GOOD ANY DEFECTS IN MATERIALS OR WORKMANSHIP WITHOUT COST TO TENANT. 0.20 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT AND RACEWAY LOCATIONS TO AVOID CONFUCTS WITH OTHER CONSTRUCTION. 0.21 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.22 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.23 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS SPECIFIED MAY BE REQUIRED FOR THIS PROJECT. 0.24 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, FAIUNG SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME. 0.25 CERTIFICATION: PROFESSIONAL ENGINEER CERTIFICATION OF THESE DOCUMENTS DOES NOT EXTEND TO STANDARDIZED DESIGN OR INSTALLATION GUIDELINES PREPARED BY OTHERS AND REQUIRED BY A THIRD PARTY TO BE INCLUDED HEREON. 0.26 DEFINITIONS: THE TERMS USTED BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DMSION 16 AND ONLY DMSION 16. A. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOB SITE IN NEW CONDITION AND GUARANTEE B. INSTALL RECEIVE AT THE JOB SITE, UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. C. PROVIDE FURNISH AND INSTALL D. REMOVE REMOVE INSTALLATION BACK TO NEXT REMAINING POINT OF USE. 16100 - MATERIALS 1.01 RACEWAY: CONTINUOUS SYSTEM, 1/2" MINIMUM EMT EXCEPT: 3/4" MINIMUM RNC WITH GROUND CONDUCTOR WHERE EMBEDDED IN CONCRETE OR MASONRY; 3/4" MINIMUM GALVANIZED RMC OR IMC WHERE EXPOSED TO WEATHER (ALSO PERMITTED WHERE EMBEDDED IN CONCRETE OR MASONRY); AND FMC (OR LTFMC IF WET LOCATION) FOR SHORT FINAL CONNECTIONS TO UGHTING FIXTURES, TRANSFORMERS, AND MECHANICAL EQUIPMENT. 1.02 IG RACEWAY: PROVIDE SEPARATE RACEWAY SYSTEM FOR IG CIRCUITS. 1.03 RACEWAY INSTALLATION: CONCEAL RACEWAY IN FINISHED SPACES. ROUTE SQUARE WITH BUILDING ONES AND SUPPORT PER NEC. DO NOT ATTACH TO OR PENETRATE HVAC DUCTS. MAINTAIN HEADROOM AND EQUIPMENT AND FLUE CLEARANCE. FIRE /SMOKE - SEAL PENETRATIONS OF RATED CONSTRUCTION. 1.04 RACEWAY ADJUSTMENTS: WHERE INDIVIDUAL HOME RUNS ARE SHOWN FOR CLARITY, COMBINE AND ADJUST RACEWAY SIZE PER FIELD CONDITIONS. 1.05 WIRE: TYPE THHN, COPPER ONLY, 12AWG MINIMUM, STRANDED FOR SAWG AND LARGER. LV WIRING FOR EMERGENCY UGHTING, 10AWG MINIMUM. USE OF ALUMINUM CONDUCTORS SHALL NOT BE ALLOWED. 1.06 COLOR CODE: COLOR CODE ENTIRE WIRING SYSTEM FROM SERVICE DISCONNECT OR TRANSFORMER THROUGHOUT ALL BRANCH CIRCUITS AS FOLLOWS: FOR 120/208 VOLT SYSTEM, PHASE A - BLACK, PHASE B - RED, PHASE C - BLUE, NEUTRAL - WHITE; FOR 277/480 VOLT SYSTEM, PHASE A - BROWN, PHASE B - ORANGE, PHASE C - YELLOW, NEUTRAL - WHITE WITH TRACER OR GRAY; GROUNDING CONDUCTOR - GREEN. 1.07 WIRE SIZE: WHERE WIRES ARE SIZED PER 60 DEG. C TEMPERATURE RATING FOR SIZES UP TO 1 AWG, SUBJECT TO COMPLIANCE WITH EQUIPMENT UL USTING, AND APPROVAL OF LOCAL AUTHORITY AND ENGINEER, SUCH WIRES MAY BE REDUCED TO 75 DEG. C RATED SIZE, WITH RACEWAY SIZE ADJUSTED ACCORDINGLY. WIRE SIZE PER 90 DEG. C TEMPERATURE RATING IS NOT APPROVED. 1.08 VOLTAGE DROP: FOR CONDUCTORS SIZED PER NEC ON DRAWINGS, INCREASE SIZE BY NUMBER OF STANDARD SIZES SHOWN IN TABLE TO COMPENSATE FOR VOLTAGE DROP. CONTACT ENGINEER FOR ASSISTANCE IF CIRCUIT LENGTH FROM SOURCE TO LOAD EXCEEDS MAXIMUMS SHOWN. CCT VOLTS /PH CCT LENGTH FT. UPSIZE 120/1 75 -150 1 120/1 150 -200 2 208/3 OR 277/1 150 -200 1 208/3 OR 277/1 200 -250 2 480/3 300-450 1 480/3 450 -550 2 1.09 TYPE MC CABLE: MC CABLE EQUIPPED WITH A GREEN INSULATED GROUND PERMITTED FOR BRANCH CIRCUITS IN CONCEALED LOCATIONS ONLY SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY. 1.10 SPUCES: SPUCE ONLY IN ACCESSIBLE JUNCTION BOXES, USING "WIRENUT" CONNECTORS FOR BAWG AND SMALLER, OR MECHANICAL COMPRESSION CONNECTORS WITH INSULATION KIT FOR 6AWG AND LARGER. 1.11 BOXES: NEMA 051 IN INTERIOR DRY LOCATIONS, CAST WEATHERPROOF TYPE IN WET LOCATIONS. 1.12 WALL SWITCHES: FED SPEC W -S -896, AC GENERAL USE, 20 AMP, 120 -277 VOLT, TOGGLE HANDLE. INSTALL 48" A.F.F TO CENTER. 1.13 WALL RECEPTACLES: FED SPEC W -C -596, NEMA 5 -20R CONFIGURATION OR AS REQUIRED. PROVIDE IG (ISOLATED GROUND) AND GFCl/WP (GROUND -FAULT CIRCUIT INTERRUPTER) RECEPTACLES WHERE APPROPRIATE OR INDICATED. INSTALL 18" A.F.F TO CENTER, OR AS INDICATED. 1.14 WALL PLATES: SMOOTH PLASTIC. KITCHEN AREA STAINLESS STEEL 1.15 WALL DEVICE AND PLATE COLOR: MATCH ADJACENT SURFACE, OR AS DIRECTED BY ARCHITECT. PROVIDE ORANGE IG RECEPTACLES. 1.16 MANUFACTURED WIRING SYSTEMS: PERMITTED FOR BRANCH CIRCUITS SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY. 1.17 GROUNDING: PROVIDE CONTINUOUS, PERMANENT, AND EFFECTIVE GROUNDING SYSTEM. GROUND SEPARATELY DERIVED SYSTEMS TO NEAREST EFFECTIVELY GROUNDED BUILDING STRUCTURAL STEEL 16400 - EQUIPMENT 4.01 DISCONNECT SWITCH: NEMA KS1, GENERAL DUTY, 3 POLE, S/N IF NEUTRAL IS PRESENT, NEMA 3R ENCLOSURE IF OUTDOORS, LOCK -OFF, NON- FUSIBLE UNLESS INDICATED WITH FUSES. 4.02 DRY -TYPE TRANSFORMER: NEMA ST20, 480:208Y120 CONNECTED, 115 DEGREE RISE, KVA RATING AS INDICATED. INSTALL USING VIBRATION ISOLATORS. STATES WITH REQUIREMENTS FOR ENERGY EFFICIENT TRANSFORMERS PROVIDE NEMA TYPE -TP1, 150' RISE. RE -USE EXISTING IF APPUCABLE. 4.03 PANELBOARD: NEMA PB1 AS SCHEDULED, 20" WIDE SECTION, 225 AMP BUS (100 AMP BUS PERMITTED IF LESS THAN 30 BRANCH POLES). PROVIDE GROUND BUS FOR IG CIRCUITS. INSTALL PER NEMA PB1.1. PROVIDE TYPEWRITTEN BRANCH CIRCUIT DIRECTORY. LOAD CENTERS NOT APPROVED. RE -USE EXISTING IF APPUCABLE AND STILL MEETS CODE REQUIREMENTS. ALL COMBINATIONS OF EQUIPMENT AND MAIN /BRANCH OVERCURRENT PROTECTION SHALL BE FULLY RATED ANC. (NEC 110.9) 4.04 CIRCUIT BREAKER: NEMA AB1 AS SCHEDULED, BOLT-ON, CENTER TRIP, SWD IF SINGLE POLE, COMMON TRIP IF MULTI -POLE, HACR IF REQUIRED BY LOAD. MATCH EXISTING EQUIPMENT. 4.05 FUSE: UL CLASS J. WHEN FUSING EXISTING EQUIPMENT FUSES SHALL BE CURRENT UMITTNG AND MATCH EXISTING FUSE MANUFACTURER PROVIDE 3 SPARE OF EACH SIZE AND TYPE INSTALLED 4.06 MAGNETIC MOTOR STARTER: NEMA ICS2, FVNR, SIZE PER MOTOR REQUIREMENTS BUT SIZE 0 MINIMUM, NEMA 3R ENCLOSURE IF OUTDOORS. PROVIDE CLASS 20 HEATERS PER ACTUAL MOTOR NAMEPLATE DATA. PROVIDE 120VAC OR 24VAC FUSED CONTROL CIRCUIT AS REQUIRED. 4.07 MANUAL MOTOR STARTER: NEMA RATED, FHP, SINGLE SPEED, TOGGLE OPERATED, MANUAL RESET OVERLOAD, NEMA 1 ENCLOSURE. 16500 - UGHTING 5.01 TENANT - FURNISHED EQUIPMENT: FOR UGHT FIXTURES AND AUXILIARY ITEMS SCHEDULED AS FURNISHED BY TENANT, RECEIVE, PROTECT, INSTALL CLEAN, AND LAMP UGHT FIXTURES AS SCHEDULED, OR EQUAL 5.02 CONTRACTOR - FURNISHED EQUIPMENT: FOR LIGHT FIXTURES SCHEDULED AS FURNISHED BY CONTRACTOR, FURNISH AND INSTALL COMPLETE, OR APPROVED EQUAL 5.03 ACCESSORIES: PROVIDE ACCESSORIES, INCIDENTAL MATERIALS AND MOUNTING HARDWARE AS REQUIRED. 5.04 LOCATION: REFER ALSO TO ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING DETAILS. 5.05 INSTALLATION: PROPERLY INSTALL AND SUPPORT ALL FIXTURES PLUMB AND TRUE, AND FREE OF UGHT LEAKS. CONFORM TO MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY PRACTICE. LEAVE PROTECTIVE FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL LIGHT FIXTURES IN RATED CEILINGS TO MAINTAIN THE RATING OF CEIUNG. 5.06 EMERGENCY UGHTING: PROVIDE AND LOCATE EMERGENCY UGHTING TO MEET LOCAL REQUIREMENTS. 5.07 FLUORESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ELECTRONIC HPF, RAPID START, PARALLEL LAMP OPERATION, CBM, TYPE 1, CLASS P, SOUND RATED A, T-IDC20%, CCF<1.5, NAECA COMPLIANT WHERE APPUCABLE, ENERGY SAVING BALLASTS. 5.08 RECESSED INCANDESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE FMC AND 150 DEGREE C FIXTURE WIRE FROM LAMP HOUSING TO INDEPENDENT BRANCH CIRCUIT OUTLET BOX. 5.09 HID FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ANSI C82.4 COMPLIANT, HPF, ENCAPSULATED BALLASTS, ADVANCE SERIES 73B OR EQUAL. 5.10 FINAL ADJUSTMENT: AFTER TRADE FIXTURES ARE INSTALLED BY OTHERS, CLEAN ALL LIGHTING FIXTURES, REPLACE ALL EXPIRED LAMPS, AND ADJUST DIRECTIONAL UGHTING AS DIRECTED BY TENANT AND ARCHITECT. 5.11 SIGN DISCONNECT: PROVIDE DISCONNECT SWITCH IN ACCESSIBLE CEIUNG SPACE FOR STORE SIGN AND MAKE FINAL CONNECTIONS. VERIFY LOCATION IN FIELD. SIGN FURNISHED AND INSTALLED BY OTHERS. COORDINATE ALL REQUIREMENTS PRIOR TO BID. 16700 - SYSTEMS 7.01 DATA SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS EMT RACEWAY SYSTEM WITH PULL WIRE FROM DATA SYSTEM EQUIPMENT LOCATION TO ALL DATA SYSTEM OUTLETS. SIZE AS SPECIFIED ON DRAWINGS, 3/4" MINIMUM. FOR NON- PLENUM ACCESSIBLE CEIUNG SPACES, AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEIUNG SPACE ARE PERMITTED IN UEU OF CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND BLANK PLATE. FOR FLOOR OUTLET PROVIDE FLOOR BOX AS ELSEWHERE SPECIFIED AND BLANK PLATE. 7.02 TELEPHONE SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS EMT RACEWAY SYSTEM WITH PULL WIRE FROM LANDLORD STUB -IN TO BACKBOARD, AND FROM BACKBOARD TO ALL TELEPHONE OUTLETS. SIZE AS SPECIFIED ON DRAWINGS, 3/4" MINIMUM. FOR NON - PLENUM ACCESSIBLE CEIUNG SPACES, .AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEIUNG SPACE WHERE PERMITTED IN UEU OF CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS, PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND TELEPHONE PLATE. FOR FLOOR OUTLET PROVIDE FLOOR BOX AS ELSEWHERE SPECIFIED AND TELEPHONE PLATE. PROVIDE 3/4" FIRE- TREATED PLYWOOD BACKBOARD OF SIZE REQUIRED FOR TELEPHONE EQUIPMENT. PROMPTLY NOTIFY TENANT WHEN ROUGH -IN INSTALLATION IS COMPLETE. 7.03 SECURITY SYSTEM ROUGH -IN: PROVIDE CONTINUOUS RACEWAY SYSTEM WITH PULL WIRE AS INDICATED FOR INSTALLATION OF SECURITY SYSTEMS BY OTHERS. ELECTRICAL SYMBOL LEGEND DRAWING SYMBOL BOL DE CRIPTION $ $ K SWITCH - SINGLE POLE TOGGLE SWITCH - SINGLE POLE KEY - OPERATED SWITCH - SINGLE POLE WITH PILOT UGHT ^- $3 SWITCH - 3 WAY 9 WALL RECEPTACLE -- DUPLEX STRAIGHT BLADE Itt WALL RECEPTACLE - FOURPLEX STRAIGHT BLADE 15IG RECEPTACLE - DUPLEX STRAIGHT BLADE, ISOLATED GROUND ifRECEPTACLE �' -- FOURPLEX STRAIGHT BLADE, ISOLATED GROUND 0.0 GFI WP RECEPTACLE - DUPLEX STRAIGHT BLADE, GROUND FAULT INTERRUPTER, WEATHER PROOF 1.00 7.9 SPLIT CIRCUIT RECEPTACLE 1.7 SPECIAL PURPOSE RECEPTACLE MULTI - OUTLET ASSEMBLY (PLUGMOLD) I • I MISCELLANEOUS 7 Q TELEPHONE OUTLET - WALL MOUNTED DATA OUTLET MOTOR - HORSEPOWER, VOLTAGE AND PHASE AS NOTED ON DRAWINGS D1 NON -FUSED DISCONNECT SWITCH -- SIZE AS NOTED ON DRAWINGS D1 NON -FUSED DISCONNECT SWITCH - SIZE AS NOTED ON DRAWINGS KITCHEN EQUIPMENT FUSED DISCONNECT SWITCH - SIZE AS NOTED ON DRAWINGS '- MAGNETIC MOTOR STARTER - SIZE AS NOTED ON DRAWINGS Q JUNCTION BOX - WALL, CEILING Ira SWITCHBOARD OR PANELBOARD TELEPHONE BACKBOARD HVAC (REMAINING) 61 BUZZER Q BELL OR CHIME PUSHBUTTON CONTROL STATION - WALL MOUNTED T LOW VOLTAGE CONTROL TRANSFORMER MI TIME SWITCH Cl CONTACTOR O THERMOSTAT (BY MECHANICAL CONTRACTOR OR AS INDICATED) C---...\ FINISHED - CONCEALED ABOVE CEILINGS, IN WALLS IN FINISHED AREAS, OR EXPOSED IN UNFINISHED AREAS � COFINNDISUIT HED - IN OR BELOW FLOOR SLAB OR BELOW GRADE CONDUIT HOMERUN TO PANEL - CROSSMARKS INDICATE NUMBER OF CONDUCTORS. NO CROSSMARKS INDICATES 2 CONDUCTORS. DOT ON CROSSMARKS INDICATES EQUIPMENT ISOLATED GROUNDING CONDUCTOR. 9 20/1 FLOOR RECEPTACLE SENSORMATIC / LOSS P. Q 0.4 FLUSH FLOOR TELEPHONE OUTLET 0 UNDER FLOOR STUB UP QS SPEAKER 0 1 EXIT UGHT 41--& EMERGENCY FIXTURE A(.4.1 LA -1 a TOP LETTER INDICATES UGHT FIXTURE TYPE, ( ) INDICATES NUMBER OF FIXTURES. REFER TO UGHT FIXTURE SCHEDULE. BOTTOM LETTER AND NUMBER INDICATES PANELBOARD DESIGNATION AND CIRCUIT NUMBER. LOWER CASE LETTER INDICATES SWITCH DESIGNATION. 9B -16 LETTER AND NUMBER NEXT TO ALL DEVICES AND CONDUIT STUB -UPS INDICATES PANELBOARD DESIGNATION AND CIRCUIT NUMBER RESPECTIVELY. NOTES: 1. ALL IG RECEPTACLES SHALL BE ORANGE. 2. A SQUARE ENCLOSING A WIRING DEVICE SYMBOL INDICATES A FLUSH FLOOR DEVICE. X NOTE: TENANT E.C. TO SPECIFY COLORS OF ELECTRICAL RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION. 20/1 1.7 NOTE; FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE SUBMITTED SEPERATELY. NOTE; ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE PERFORMED UNDER SEPERATE PERMIT. NOTE: ALL SPEAKER WIRING SHALL BE FURNISHED AND INSTALLED BY TENANT'S VENDOR. 1411T5 TO LINE 2 (ROLLOVER) POINT OF DEMARCATION (MALL TEL 'HONE CLOSET OR STORE STOCKROOM) TELEFOONE BLOCK (BY LOCAL TE..EPHIOtNE PROVIDER) LINE I TRANS WORLD STORE PREM15E5 >LINE 2 T -I LINE f13YT ff) 8145 JACK VOICE LINE5 1 AND 2 O 00 O 00 O 00 O 00 8114 TWO -LINE JACK IN STOCKROOM R114 THO -LINE JACK IN STOCKROOM 10 0 0 I R.114 TWO -LINE JACK AT CASH WRAF lo 01 000 RJ 14 TWO -LINE JACK AT CASH WRAP OR ON SALES FLOOR Lo 0 o I SS- INbI E 1.11E .TACK AT I5P LOCATION ONLY (P05 MODB'Q, BY TENANT O 0 0 0 O 0 0 0 CATEGORY 5 DATA GABLE (AT ISP LOCATION - P.0.5. MODEM) EEEE RJ 45 JACK (AT GASH WRAP) NOTE ADDITIONAL TELEPHONE LOCATIONS WITHIN STORE MAY BE REQ)IR®. COORDINATE EXACT LOCATIONS AND QUANTITY WITH TENANT FRO.EGT MANAGER. NOTE: ALL CABLE SHALL BE PLENUM RATED. 3 TYPICAL TELEPHONE WIRING SETUP \.E.2.1 NO SCALE LA - LOAD SUMMARY LOCATION: STOCKROOM CONN. KVA DEM FACT. DEM. KVA _ SIGN / NEON SIGN 1.2 1.25 1.5 LIGHTING 2.1 1.25 2.6 TRACK LIGHTING ** 0.0 1.00 0.0 RECEPTACLES 7.9 1.00 7.9 WATER HEATER 1.7 1.00 1.7 MISCELLANEOUS 2.6 1.00 2.6 MOTORS 0.0 1.25 0.0 KITCHEN EQUIPMENT 0.0 0.65 0.0 HVAC (LARGEST) 0.0 1.25 0.0 HVAC (REMAINING) 0.0 1.00 0.0 20/1 5 X TOTAL 15.5 20/1 16.3 CASHWRAP REC. SPARE 0.0 20/1 ** DEMAND PER NEC 410-101B AND 220 -12B TOTAL TRACK LENGTH INSTALL ALL DEVICES ®IS" AFF BEHIND FINISHED CABINET. E1_EGTRIGAL CONTRACTOR TO LABEL J- BOXES. NOTE: FOLDING SHELF CAM BE MOUNTED ON EITHER SIDE. HOLES ARE PRE- DRILLED. Plan Yew NOTES: RISER DIAGRAM BASED ON INFORMATION AVAILABLE. ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING EQUIPMENT BEING REUSED IS ADEQUATE AND UP TO CURRENT CODES. ELECTRICAL CONTRACTOR TO FIELD VERIFY ALL ELECTRICAL EQUIPMENT PRIOR TO BIDDING JOB. Q MALL DISTRIBUTION NOTE; TENANT PANELBOARDS, DISTRIBUTION EQUIPMENT, AND OVER CURRENT DEVICES SHALL BE DESIGNED TO SAFELY WITHSTAND THE AVAILABLE FAULT CURRENTS, RATED IN RMS SYMMETRICAL AMPERES. NOTE TENANT'S ELECTRICAL CONTRACTOR TO COORDINATE AIC RATINGS OF ALL EQUIPMENT". LEASE LINE 17,122 AFC 15 IL J Q PANEL HA Q T PANEL LA 10 TENANT SPACE POWER RISER DIAGRAM NOT TO SCALE RISER DIAGRAM NOTES 0 LANDLORD'S EXISTING 277/480 VOLT, 3PH, 4WIRE MIAN DISTRIBUTION BOARD TO REMAIN. Q EXISTING METER AND METER SOCKET BY LANDLORD TO REMAIN. Q EXISTING 200A /3P CIRCUIT BREAKER BY LANDLORD TO REMAIN. 0 EXISTING 2 11C. -4#3/0 THHN -CU. & 1#6 GROUND WIRE BY LANDLORD TO REMAIN. FIELD VERIFY EXACT STUB -IN LOCATION. Q EXISTING 200A /3P DISCONNECT SWITCH WITH (3) 200A FUSES BY LANDLORD TO REMAIN. Q 2 "C -4 #3/0 THHN -CU. & 1#6 GROUND WIRE. PANEL INFORMATION "HA". SEE PANELBOARD SCHEDULE FOR MORE . O 11°C-3#8 THHN -CU. Q FLOOR MOUNTED 30 KVA TRANSFORMER. 10 1#8 BARE COPPER GROUND AND TIE TO BUILDING STEEL PER NEC. 11 1 1/4-c -43 THHN -CU. 12 PANEL "LA ". SEE PANELBOARD SCHEDULE FOR MORE INFORMATION. 13 TIMESWITCH (TS1). SEE SHEET El FOR SPECIFICATION. 14 CONTACTORS (C1), (C2) & (C3). SEE SHEET El FOR SPECIFICATION. 15 AVAILABLE FAULT CURRENT PER LANDLORD PROVIDED INFORMATION. No.: HA LOCATION: STOCKROOM MOUNTING SURFACE RATED AIC: 277/480 VOLT 3 PHASE, 4 WIRE 22,000 MAIN: LO 225 AMP CIRCUIT DESCRIPTION KVA CB No. HL A B C HL No. CB KVA CIRCUIT DESCRIPTION EXIT /EM /NL (EM/A,E) 0.4 20/1 1 * X 1.00 2 MOTORS 5.6 1.25 SALES AREA LTG.(A) 1.6 20/1 3 0.0 X 5.9 4 50/3 5.1 30 KVA TRANSFORMER SALES AREA LTG.(A) 1.4 20/1 5 X TOTAL 6 20/1 4.8 CASHWRAP REC. SPARE 0.0 20/1 7 X 8 20/1 2.5 SENSORMATIC / LOSS P. STOCKROOM LTG. 0.4 20/1 9 X 10 20/3 1.7 VAV -1 SPARE 0.0 20/1 11 X 12 20/1 1.7 _ STORE SIGN SPARE 0.0 20/1 13 X 14 20/1 1.7 SALES AREA REC. SPARE 0.0 20/1 15 X 16 20/3 1.7 VAV -2 SPARE 0.0 20/1 17 X 18 20/1 2.5 SALES AREA REC. SPACE 0.0 20/1 19 X * 20 20/1 0.2 SPACE SPACE 0.0 20/1 21 X 22 20/1 0.2 SPACE SPACE 0.0 20/1 23 X * 24 20/1 0.4 SPACE SPACE 0.0 20/1 25 X 26 20/1 0.4 SPACE SPACE 0.0 20/1 27 X * 28 20/1 0.4 SPACE SPACE 0.0 20/1 29 X 30 20/1 0.4 SPACE SPARE 0.0 20/1 31 A T B I C 32 20/1 0.6 HVAC REC. /LTG. CONNECTED LOAD: CALCULATED CODE DEMAND LOAD 38 AMPS MAX 3t1 KVA 10.2 10.5 10.4 34.4 KVA 41 AMPS • HL = INDICATES HANDLE LOCK DEVICE ON CIRCUIT BREAKER(S) (E)= EXISTING EQUIPMENT TO REMAIN HA - LOAD SUMMARY LOCATION: STOCKROOM CONN. KVA DEM FACT. DEM. KVA SIGN / NEON SIGN 1.2 1.25 1.5_ .. LIGHTING 5.9 1.25 7.4 TRACK LIGHTING ** 0.0 1.00 0.0 RECEPTACLES 7.9 1.00 7.9 WATER HEATER 1.7 1.00 1.7 MISCELLANEOUS 2.6 1.00 2.6 MOTORS 0.0 1.25 0.0 KITCHEN EQUIPMENT 0.0 0.65 0.0 HVAC (LARGEST) 5.9 1.25 7.4 HVAC (REMAINING) ' 5.9 1.00 5.9 20/1 5 X TOTAL 31.1 20/1 34.4 CASHWRAP REC. SPARE 0.0 20/1 ** DEMAND PER NEC 410-101B AND 220 -12B TOTAL TRACK LENGTH No.: LA LOCATION: STOCKROOM MOUNTING SURFACE RATED ANC: 120/208 VOLT 3 PHASE, 4 WIRE 10,000 MAIN: CB 100 AMP CIRCUIT DESCRIPTION KVA CB No. HL A B C HL No. CB KVA CIRCUIT DESCRIPTION S.F. DOWN LT.(D, PL) 0.3 20/1 1 X * 2 20/1 0.4 CASH REGISTER NEON LIGHTS (N) 0.8 20/1 3 X 4 20/1 0.4 CASH REGISTER SALES DOWN LT. (D1) 0.4 20/1 5 X * 6 20/1 1.0 CASHWRAP REC. SPARE 0.0 20/1 7 X 8 20/1 0.8 SENSORMATIC / LOSS P. SALES DOWN LT. (D1) 0.4 20/1 9 X 10 20/1 0.6 SHOW WINDOW REC. TOILET LTG./FAN 0.2 20/1 11 X 12 20/1 1.2 _ STORE SIGN WH -1 1.7 20/1 13 X 14 20/1 1.2 SALES AREA REC. STOCKRM REC. 1.0 20/1 15 X 16 20/1 1.2 SALES AREA REC. TOILET GFI REC. 0.2 20/1 17 X 18 20/1 1.0 SALES AREA REC. SPARE 0.0 20/1 19 X * 20 20/1 0.2 LVS STATION REC SPARE 0.0 20/1 21 X 22 20/1 0.2 VENTED CABINET REC. SPARE 0.0 20/1 23 X * 24 20/1 0.4 AN RACK REC. SPARE 0.0 20/1 25 X 26 20/1 0.4 TELEPHONE REC. SPARE 0.0 20/1 27 X * 28 20/1 0.4 P.O.S STATION SPARE 0.0 20/1 29 X 30 20/1 0.4 WORK/FOLDING TABLE SPARE 0.0 20/1 31 X 32 20/1 0.6 HVAC REC. /LTG. SPARE 0.0 20/1 33 X 34 20/1 0.1 TIMESWITCH/ BUZZER SPARE 0.0 20/1 35 X 36 20/1 0.0 SPARE SPACE 37 X 38 SPACE SPACE 39 X 40 SPACE SPACE 41 X 42 SPACE A I B I C CONNECTED LOAD: CALCULATED CODE DEMAND LOAD 47 AMPS MAX 15.5 KVA 5.6 5.1 4.8 16.3 KVA 45 AMPS * HL = INDICATES HANDLE LOCK DEVICE ON CIRCUIT BREAKER(S) (E)= EXISTING EQUIPMENT TO REMAIN 110 VAC OUTLET IN AN ACCESSIBLE LOCATION ABOVE CEIUNG WITHIN 10' -0" OF CONTROL MODULE. CONTROL MODULE IN AN ACCESSIBLE LOCATION ABOVE CEIUNG. CENTERLINE OF ROLL-UP GRILLE LA -8 SENSORMATIC UNIT TYP. $' -0" SENSOR PLACEMENT SCHEME TYPICAL DETAIL -3' 1/4" =1' -O" NOTE: SEE FLOOR PLAN FOR CORRECT ORIENTATION. NOTE: VERIFY SENSORMATIC INSTALLATION WITH TENANT'S PROJECT MANAGER PRIOR TO CONSTRUCTION. SEE E -2 FOR SPECIFIC KEYNOTES t1.0S--2-011 CITY ut- MAP 037008 PERMIT CENTER Z m O STORE NO: 1248 E- C-) DRAWN BY: U CO CHECKED BY: PROJECT COORDINATION: SHEET NUMBER E -3 SHEET 17 OF 17