HomeMy WebLinkAboutPermit EL08-0204 - WESTFIELD SOUTHCENTER MALL - FYE2636 SC MALL
07-24-08
ELO8-204
Cityef Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ELECTRICAL PERMIT
Parcel No.: 6364200010 Permit Number: EL08 -204
Address: 2636 SOUTHCENTER MALL TUKW Issue Date: OS/30/2008
Suite No: Permit Expires On: 12/16/2008
Tenant:
Name: FYE
Address: 2636 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: DEVON REDMON Phone: 310 328 -6300
Address: 1327 POST AV, STE H , TORRANCE CA
Contractor:
Name: NEAL ELECTRIC INC Phone: 425 471 -1654
Address: 23036 NE 29 ST , SAMMAMISH WA
Contractor License No: NEALEI *022M9 Expiration Date: 09/19/2008
DESCRIPTION OF WORK:
TENANT IMPROVEMENT: INSTALL LIGHTING, RECEPTACLES, AND ELECTRICAL PANELS
REVISION #1 INCLUDES ADDING TEMP PANEL TO PERMIT.
Value of Electrical: $19,000.00
Fees Collected:
$585.75
Type of Fire Protection: National Electrical Code Edition: 2005
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be compile
x.
wi
Date:
a/0-101
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this electrical permit.
Signature:
Print Name:
Date:
074
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -204 Printed: 06-27 -2008
CitAf Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
ELECTRICAL PERMIT
Parcel No.: 6364200010
Address: 2636 SOUTHCENTER MALL TUKW
Suite No:
Permit Number: EL08 -204
Issue Date: 05/30/2008
Permit Expires On: 11/26/2008
Tenant:
Name: FYE
Address: 2636 SOUTHCENTER MALL , TUICWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: DEVON REDMON Phone: 310 328 -6300
Address: 1327 POST AV, STE H , TORRANCE CA
Contractor:
Name: NEAL ELECTRIC INC
Address: 23036 NE 29 ST , SAMMAMISH WA
Contractor License No: NEALEI *022M9
Phone: 425 471 -1654
Expiration Date: 09/19/2008
DESCRIPTION OF WORK:
TENANT IMPROVEMENT: INSTALL LIGHTING, RECEPTACLES, AND ELECTRICAL PANELS
Value of Electrical: $19,000.00
Fees Collected:
$492.00
Type of Fire Protection: National Electrical Code Edition: 2005
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:,,
Date: [S-/9A `0 0
I hereby certify that I have read and xa ;ned this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complie whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perfo ance of work. I am authorized to sign and obtain this electrical permit.
Signature: �— Date: 1136/PS
Print Name:
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -204 Printed: 05-30 -2008
� •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 6364200010
Address: 2636 SOUTHCENTER MALL TUKW
Suite No:
Tenant: FYE
Permit Number: EL08 -204
Status: ISSUED
Applied Date: 03/03/2008
Issue Date: 05/30/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, arty violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local
laws regulating construction or the performance of work.
Signature: Date: S/30/0 g
C L lI L
Print Name:
doc: Cond -Elec
EL08 -204 Printed: 05 -30 -2008
CITY OF TUKWILIP
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
I1ttp: /Avtvvi.ci tiikivda. tva.us
•
Electrical Permit No.
Project No.
f1}N 261
COS -05D
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
Site Address:
50 ( N`�\\
Tenant Name: P. 1 . c -
Property Owners Name:
Mailing Address: ! / 6 0/
King Co Assessor's Tax No.: r -.3L 'I-� - D() /
Suite Number: 2tteC F oor:
New Tenant: Yes ❑ ..No
CONTACT PERSON - Who do we contact when your permit is ready to be issued
Name: ‘)0,./N. Pe. ���,� Day Telephone: 31 d 3.��' -6 O der /L
Mailing Address: \ 2 171)1+- A'-"LC. 54e.
City State Zip
E -Mail Address: V ' 9 �X� '- 5Xpef' h1 i Cec -tax Number: 7/ U �s ��� ee-
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State Zip
Valuation of Project (contractor's bid price): $ 1 ` t O O0
Scope of Work (please provide detailed information): Iv‘S \-u'\ \ 1
(,L ,If/ a-5 1VAC- 11ctt—,L4 i�v� k' atre-�74.7f-s., a
P
Will service be altered? ❑ Yes No
Type of Use: IY 1'e rc c - ^�1
Tyne of work:
New ❑ Addition
❑ Low Voltage ❑ Generator
Property Served by:
Puget Sound Energy
❑ Seattle City Light
Adding more than 50 amps? ❑ YesNo
❑ Service Change ❑ Remodel \ Tenant Improvement
❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
HAApphcalionsWFom s- Apphcatons On Irnt4 -2007. Electncal Pmt Applicanon.doc
bh
Page 1 of 2
1
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $10.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair S65.00
❑ Low voltage systems 555.00
(alarm, furnace thermostat)
MULTI - FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR ELECTRICAL CONTRACTOR:
Signature:
Print Name:
%27 i et /A? 9 Z c r�
Mailing Address: Tr #�
Date Application Accepted: obi ,��IO97 i Date Application Expires:
HApplicanons\Forms- Applications On IJnet4 -2007 - Electrical Permit Apphcationdoc
bh
Date: 3/3x0 Y/
Day Telephone:
5'.i -f /P
City
Oct I irf4
Lc) >4
State
Staff Initials:
Rg
Zip
Page 2 of 2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 - 431 -3665
Web site: http.• / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -204
Address: 2636 SOUTHCENTER MALL TUKW Status: ISSUED
Suite No: Applied Date: 03/03/2008
Applicant: FYE Issue Date: 05/30/2008
Receipt No.: R08 -02327
Initials: JEM
User ID: 1165
Payment Amount: $75.00
Payment Date: 06/27/2008 10:23 AM
Balance: $0.00
Payee: NEAL ELECTRIC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash 75.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 75.00
Total: $75.00
4186 06/27 9711 TOTAL 75.00
doc: Receipt -06 Printed: 06-27 -2008
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http../Iwww.cittikwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -00594
Initials: JEM Payment Date: 03/03/2008
User ID: 1165
Payee: EXPRESS PERMITS
Total Payment: 714.30
SET ID: S000000972 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08 -115 520.65
.,EL0f84:bat 98.40
M08 -061 63.25
PG08 -066 32.00
TOTAL: 714.30
TRANSACTION LIST:
Type Method Description Amount
Payment Check 11076 714.30
TOTAL: 714.30
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000.345.832.00.0 98.40
000/345.830 615.90
TOTAL: 714.30
:1 U/03 T710 TOTAL 714.7_i
CI•44 0'204
INSPECTION NO. PERMIT NO. ;
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 67
INSPECTION RECORD
Retain a copy with permit
Project: r Y 6
Type of Inspection: ;10V
Address: 2- % ° it
Date Called:
Special Instructions:
/
Date Wanted: ,�
a:m.
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
Inspector: LtrJ&'
ek
(Date: 047-tier
❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
kol-vaki
PERMIT NO.
Tr—
(206)431-36 V0
Project: ri E.,
Type of Inspection:
`�
Address: 70 4
1 r
Date Called:
�"--...,
Special Instructions:
Date Wanted:
1 Z
a.m.
p.m.
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Pik
- CatetiCT 104, fikpf
° -1 5
((1.144/ Qtyoltkirt\ (te
igmielor hpeozwet___ or
Ot2655 1,14 undll
Inspector: / I vU
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
(Loy-Zo
PERMIT NO. f
CITY OF TUKWILA BUILDING DIVISION Va-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3
Project: F
p Type of Inspection:
2P0O
,
— Q°r49 14oT 'Ti cot".
Address: �3 6 ` ie
Date Called:
- 6(- C4.f Fat tatAlt-72._ Fo'»J t4
— 14.o. 561t/ P11 SS( 400 i l}Nh 1
Special Instructions:
Date Wanted:
- ��
t
Requester:
Phone No:
0 Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
— $DLX - 00-
,
— Q°r49 14oT 'Ti cot".
Hower %is , CASethlkOff , SCGi116
lit Diet" Tly404 L octr r
- 6(- C4.f Fat tatAlt-72._ Fo'»J t4
— 14.o. 561t/ P11 SS( 400 i l}Nh 1
- BoAl c 1. L 1 1504t5 Asr C idtAPP
Inspector:
66init•
Date:
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
CITY OF TUKWILA BUILDING DIVISION 1'1-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367
Project: j.
�
�
Type of Inspection:
7002
7D0,
Address: �
3
Date Called:
Special Instructions:
Date Wanted:
1/�'
a:m
Requester:
Phone No:
Approved per applicable codes. 0 Corrections required prior to approval.
COMMENTS:
nspector:
Date:
oliZr ro�
LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.: 'Date:
d _a w ten...:. • ..� - ��..� .... .e -_
INSPECTION NO.
INSPECTION RECORDLJ,�
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION It.
6300 Southcenter Blvd., #100, Tukwila, WA 98188
(206)431 -36j70
Project: F
y
Type of Insp ,:in:
—2 `o
/7vj-
Address:
� ��
D ate Call
Special Instructions:
Date Wanted:
a.m.
p.m.
Requester:
Phone No:
proved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
'X
706
£ /L /A6 --)L /, /?
1/ -- 181)W. fLOK £Z(/ ZIPS
_7_ ij , s
Insl*L. &reAIi Dat7/ o a <
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
y._
INSPECTION NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
(206)431 -36'0
Project: r-: •` ,i_
/y r
Type of II�Spe
io
Addres
236 S� /49G L.
Date Called:
7 0 774/as - f cL M6 ,t411) X D
Special Instructions:
Date Wanted:
a.m.
p.m.
Requester:
f-lir./a f 9AJ/ z
Phone No:
LiApproved per applicable codes. '2orrections required prior to approval.
COMMENTS:
700 2-,
DGRolowEL4 C 7`_'o1 GuRIA c7;(
7 0 774/as - f cL M6 ,t411) X D
:75), >~E'tvL (' /, T uNM: /445
Frail 6 E , -f CL LS -57-/al .l •trl6- (/ bL7h6E
/9 ,)IN ?/7',i 1 coZ. S f('/
f-lir./a f 9AJ/ z
C
Insp
f/ ' 4h'6
Date:
7/1 9 /0 C(
$58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
eLog-zDti
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION It
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: r‘i 6
Type of Inspection:
70o
TA
Address: 243(0 PtAtid
Date Called:
C6IL2' k cam ,
Special Instructions:
Date Wanted:
-thy 1!f
m.
Requester:
Phone No:
Approved per applicable codes. DCorrections required prior to approval.
COMMENTS:
TA
b.c - 5 Deo
C6IL2' k cam ,
Wilt- &502-4 itkov -or TAP
LAI WTI AllA C-0 (PS
Lc'O&6 Sort- T1i..L5, ow-r kit..
Inspector: 111 /36Abelec
Date: O1 {t fOt
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
.�..�.__�. • -- - -- - J1r.,..a.....A.1• _.a c.�s_- ...s.. • elm r. - L. . - i E lfih SA, "`b- 5+,.ats .
INSPECTION RECORD
Retain a copy with permit
64- 2'01
INSPE ION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: F.Y 6
Type of Inspection:
700,
Address:e� 6
Date Called:
Special Instructions:
Date Wanted:
l j 11
rJ
a m
Requester:
Phone No:
❑ Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspector:
Date:
0-7/1/ (O1/4i
n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project y ifc
Type of Inspection:
Add a s:
ee.
Date Called:
Special Instructions:
Date Wanted: �/ ",
Vim.,
p.
Requester:
Phone No:
roved per applicable codes. Corrections required prior to approval.
OMMENTS:
(K-- &eiW/GL
7 r f
faALLA
Inspe o ?
j t it, i 4(Gl-
Date: —7/316
$58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
.�.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION IL
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431-
Project: Type of Inspection: -7(
Addres • , Date Called:
2 ' ''G • AWL
pecial Instructions: Date Wanted: / a. .
/ d.r
Requester:
Phone No:
Approved per applicable codes. ,Corrections required prior to approval.
COMMENTS: fi, n (f;'4P-)/
1,) f X:w I 4;'` , c- / , ( ,f it <% 5 //1)
M/ ',v A Cifrviilc.--j
r
t iy /WN 4-VC fii,'z .4 /A%6
_ -c:-7A 6'L -- AO Mir- - -C, ' AA Lam/ c bi /4J
alit - i72r. _\ .fir. /G r
Approved per applicable codes. ,Corrections required prior to approval.
COMMENTS: fi, n (f;'4P-)/
1,) f X:w I 4;'` , c- / , ( ,f it <% 5 //1)
M/ ',v A Cifrviilc.--j
r
t iy /WN 4-VC fii,'z .4 /A%6
_ -c:-7A 6'L -- AO Mir- - -C, ' AA Lam/ c bi /4J
alit - i72r. _\ .fir. /G r
,/:5`&7,4fiiii61-/
Date: 7 it-7 /��
$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
two
3
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 'f"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: F.Yi
Type of Inspection: 76763
Addr4ss 6 6C
/17
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone No:
roved per applicable codes. El Corrections required prior to approval. .
OMMENTS:�
trX--- C- //v( -- S
/161/ L /IS 4-som 7—
Inspe ;4 6/74/46,91/6/i
Date:/ /,5 4
EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION Ill
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
e
Project: /4 yk
r
Type of Inspection:
...
.....,
j
I� 6
„g
Date Called:
vi,,/(
i vsS
Special Instructions:
Date Wanted:
6 !/
5
mi
Requester:
Phone No:
roved per applicable codes. Corrections required prior to approval.
COMMENTS:
Q/ 7 - ,NOT
4444ily
64
61,6:‹- — 0 - iiiiiiiL
vi,,/(
— e4ca( (*c
i vsS
Insp ildr (f;1u' / Date: //876k
J $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
t
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
6teg_zoq
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION le,
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: F--16
Type of Inspection:
•n._
I 003
Address: i(9 3 67
`,i�
Date Called:
Special Instructions:
Date Wanted:
f3
a.m.
Requester:
Phone No:
0 Approved per applicable codes. Ei Corrections required prior to approval.
COMMENTS:
PA
D • h _ — 54a5 LiI A-U;5
Inspector:
4NIAltik
Date: 06/13
op
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
Date:
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary
LTG - I NT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Project Info
Project Address "'
t •' f South Center Mall
Date 2/21/2008
s
For Building Department Use
REVISED
CODE COryp��MPLI
CPR ®h E
6,_, t4„.... Seatt3,b, WA. 98188
Applicant Name: W.J. Sutherland & Associates Inc.
Applicant Address: 6300 W old Shakopee Road Bloomington, MN. 55438
Applicant Phone: 952- 346 -4180 , FAX = 952- 346 -4181
Project Description
[-New Building ❑ Addition ❑ Alteration ❑ Plans Incl', ded MAR 2 5 21
Refer to WSEC Section 1513 for controls and commissioning require ents. (w/
Option
O Prescriptive 0 Lighting Power Allowance 0 Systems ^ a sil s' Tuk
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clean ony�la Cg `��
Alteration Exceptions
(check appropriate box - sec. 1132.3)
tl
❑ No changes are being made to the lighting �,s.
❑ Less than 60% of the fixtures new installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage
Location
(floor /room no.)
Occupancy Description
Allowed
Watts per ft2"'
Area in ft2
Allowed x Area
1st Floor
Retail
1.50
3631.0
5446.5
Sales
"D" 1 -50w MR16, 4" Downlight, Recessed Flood
3
50.0
150.0
Sales
"01" 1 -70W PAR38, MB FL
15
70.0
1050.0
" From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
5446.5
Proposed Lighting Wattage
Location
(floor /room no.)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Sales
"A" 3 -40w Fluorescent U-Tube
36
92.0
3312.0
Sales
"D" 1 -50w MR16, 4" Downlight, Recessed Flood
3
50.0
150.0
Sales
"01" 1 -70W PAR38, MB FL
15
70.0
1050.0
Toilet
"F" 1 -100W Incandescent, Fan /Light Combo
1
100.0
100.0
Sales
"PL" 2 -42W CFL, 9" Downlights, Recessed
2
94.0
188.0
Sales
"N" 1 -50W, NEON
1
54.0
54.0
Stock /Corridor
"SF" 2- F32T8, Surface Mount, 48"
7
58.0
406.0
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
5260.0
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if
included). For track lighting. list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual
may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable,
the wattage of current limiting devices or of the transformer.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank.
HIE COSY
NCE
I)
R�^
CITY or wr v.:•. ''
MAR 0 3 2008
PERMIT CENTER
toy
2006 Washington State Nonresidential Energy Code Compliance Form
Interior Lighting Summary .(back)
LTG -INT
2006 Washington State Nonresidential Energy Code Compliance Forms
Revised July 2007
Prescriptive Spaces
Occupancy:
Q Warehouses, storage areas or aircraft storage hangers 0 Other
Qualification Checklist
Note: If occupancy type is "Other" and fixture
answer is checked, the number of fixtures in
the space is not limited by Code. Clearly
indicate these spaces on plans. If not
qualified, do LPA Calculations.
Lighting
Fixtures:
(Section
1521)
Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted.
1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector
or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec-
tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify.
2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts
3. LED lights.
TABLE 15 -1 Unit Liahtina Power Allowance (LPA
Use'
LPA` (W /sf)
Use'
LPA` (W /sf)
Automotive facility
0.9
Office buildings, office /administrative areas in
facilities of other use types (including but not limited
to schools, hospitals, institutions. museums, banks,
churches)5'7'11
1.0
Convention center
1.2
Penitentiary and other Group 1 -3 Occupancies
1.0
Courthouse
1.2
Police and fire stations'
1.0
Cafeterias, fast food establishments',
restaurants /bars5
1.3
Post office
1.1
Dormitory
1.0
Retail10, retail banking, mall concourses, wholesale
stores (pallet rack shelving)
1.5
Exercise center
1.0
School buildings (Group E Occupancy only), school
classrooms, day care centers
1.2
Gymnasia, assembly spaces"
1.0
Theater, motion picture
1.2
Health care clinic
1.0
Theater, performing arts
1.6
Hospital, nursing homes, and other Group 1 -1 and
1 -2 Occupancies
1.2
Transportation
1.0
Hotel /motel
1.0
Warehouses'', storage areas
0.5
Hotel banquet/conference/exhibition hall"
2.0
Workshops
1.4
Laboratory spaces (all spaces not classified
"laboratory" shall meet office and other appropriate
categories)
1.8
Parking garages
0.2
Laundries
1.2
Libraries5
1.3
Plans Submitted for Common Areas Only'
Manufacturing facility
1.3
Main floor building lobbies° (except mall concourses)
1.2
Museum
1.1
Common areas, corridors, toilet facilities and
washrooms, elevator lobbies
0.8
Footnotes for Table 15 -1
1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned
specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most
comparable use specified in the table. See Section 1512 for exempt areas.
2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed
otherwise by subsequent footnotes.
3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet.
4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly.
5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet.
6) Reserved.
7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used.
8) Reserved.
9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is
2.60 W /ft2.
10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by
walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves
with the display are exempt.
An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following:
a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall).
b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points
of track attachment).
c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps.
This additional lighting power is allowed only if the lighting is actually installed.
11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for
computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only)
of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks.
w.
2006 Washington State Nonresidential Energy Code Compliance Form
Lighting,
2006 Washington State
Motor, and Transformer Permit :Plans Checklist *LTG -CHK
Nonresidential Energy Code Compliance Forms Revised July 2007
Project Address .,., South Center Mall
Date 2/21/2008
The following information is necessary to check a permit application for compliance with the lighting, motor. and transformer requirements
in the 2006 Washington State Nonresidential Ene gy Code.
Applicability
(yes, no, n.a.)
Code
Section
Component
Information Required
Location
on Plans
Building Department
Notes
LIGHTING CONTROLS (Section 1513)
yes
1513.1
Local control /access
Schedule with type, indicate locations
yes
1513.2
Area controls
Maximum limit per switch
n.a.
1513.3
Daylight zone control
Schedule with type and features, indicate locations
tl. a.
vertical glazing
Indicate vertical glazing on plans
n.a.
overhead glazing
Indicate overhead glazing on plans
yes
1513.4
Display /exhib /special
Indicate separate controls
1513.5
Exterior shut -off
Schedule with type and features. indicate location
n.a.
(a) timer w /backup
Indicate location
n. a.
(b) photocell.
Indicate location
1513.6
Inter. auto shut -off
Indicate location
yes
1513.6.1
(a) occup. sensors
Schedule with type and locations
yes
1513.6.2
(b) auto. switches
Schedule with type and features (back -up, override capability);
Indicate size of zone on plans
n.a.
1513.7
Commissioning
Indicate requirements for lighting controls commissioning
EXIT SIGNS (Section 1514)
yes
1514
Max. watts
Indicate watts for each exit sign
I
LIGHTING POWER ALLOWANCE (Section 1530 -1532)
yes
1531
Interior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
n.a.
1532
Exterior Lighting
Summary Form
Completed and attached. Schedule with fixture types,
lamps, ballasts, watts per fixture
MOTORS (Section 1511)
n.a.
I 1511
IElec motor efficiency
IMECH -MOT or Equipment Schedule with hp, rpm, efficiency
I
TRANSFORMERS (Section 1540)
yes
I 1540
Transformers
'Indicate size and efficiency
I
I
If "no" is circled for any question, provide explanation:
PERMIT COORD COPY •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -204
PROJECT NAME: FYE
DATE: 03 -03 -08
SITE ADDRESS: 2636 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
F3uiPing ivision
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete 17f
Comments:
Incomplete
DUE DATE: 03-04-08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROU ING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 04-01-08
Approved Approved with Conditions 1 r 1 Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/rouung slip.doc
2 -28 -02
•
City of Tukwila
•
11
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http://www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date:
Plan Check/Permit Number:
❑ Response to Incomplete Letter #
❑ Response to Correction Letter #
❑ Revision # after Permit is Issued
❑ Revision requested by a City Building Inspector or Plans Examiner
Ft/ 6 — I:D {o J(, EL
1J7\T 1 aJ c"
Project Address: I )'3 b S �� 0\1\
L -
Contact Person: -JD L\ L Phone Number:
Summary of Revision:
—176- 11612.Arl f (_)■--3t-1\) 0'0
Project Name:
REC
2 7 2008
t'EHMI I CENTEh
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
)] Entered in Permits Plus on (p(21'1J�
\applications\forms- applications on line\revision submittal
Created: 8 -13 -2004
Revised:
Look Up a Contractor, Elect Electriin or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
NEALEI *022M9
Licensee Name
NEAL ELECTRIC INC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
602647877
Ind. Ins. Account Id
Business Type
CORPORATION
Address 1
23036 NE 29TH ST
Address 2
City
SAMMAMISH
County
KING
State
WA
Zip
98074
Phone
4254711653
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
7/29/1998
Expiration Date
9/19/2008
Suspend Date
Separation Date
Parent Company
Previous License
Next License
Associated License
NEAL *JC962DR
Master Electrician Information
License
NEAL *JC962DR
Name
NEAL, JOEL C
Status
ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
NEAL, JOEL C
01/01/1980
•
Bond Information
Bond Bond
I I I
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= NEALEI *022M9 05/30/2008
•
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Fax: 206 -431 -3665
Web site: http://www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -204
Address: 2636 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 03/03/2008
Applicant: FYE Issue Date:
Receipt No.: R08 -01876
Payment Amount: $393.60
Initials: JEM Payment Date: 05/30/2008 02:50 PM
User ID: 1165 Balance: $0.00
Payee: NEAL ELECTRIC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Cash 393.60
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 393.60
Total: $393.60
3037 05/30 9711 TOTAL 393.60
doc: Receiot -06 Printed: 05-30 -2008
J
MUSIC
Material Symbol Key
4b~ a
MUM
%W.
[�C
l
+ + + + + + + + ++
+ + + + + + + ++
+ + + + + + + + + +
ACOUSTICAL CEILING
CONCRETE
BATT /LOOSE INSULATION
STEEL
FINISHED WOOD
GYPSUM WALLBOARD
BLOCKING /ROUGH LUMBER
RIGID INSULATION
PLYWOOD
GLASS
PARTICLE BOARD
Symbol Key
- CSI SPECIFICATION DIVISION NUMBER
5
ITEM, NOTE OR UNE NUMBER
ELEVATION KEY NUMBER
SHEET NUMBER
DETAIL OR SECTION KEY NUMBER
SHEET NUMBER
- KEY TO WALL & FASCIA
FINISH SCHEDULE
EY TO FLOOR
FINISH SCHEDULE
Ca 7. KEY TO CEILING & SOFFIT
FINISH SCHEDULE
KEY TO WALLS AND
PARTITION SCHEDULE
Fire Ratings
CARPET
MIWKEN MODULAR — TONAL VISTAS
CLASS "1" RATING
CRITICAL RADIANT FLUX— ASTM TEST E -648 : >0.45 W/CM2
OPTICAL DENSITY OF SMOKE— ASTM TEST E -662 : <450 FLAMING
WALL PARTITIONS
SALES TO STOCKROOM: NEW NON—RATED PARTITION
TENANT TO TENANT: 1 HOUR RATED PARTITION TO ABOVE CEILING; PER UL #U -465
TENANT TO SERVICE CORRIDOR: 1 HOUR RATED PARTITION TO DECK; PER UL 1 -465
CEILING SYSTEM
CEIUNG SYSTEM: CLASS "A"
FINISHES
SLAT WALL: CLASS "C"
PLASTIC LAMINATE: CLASS "C" MOUNTED TO CLASS "A"
VINYL COMPOSITE 11LE: CLASS "1"
VINYL COVE BASE: CLASS "1"
FLOOR TILE CLASS "1"
Copyright
These drawings shall remain the exclusive property
of THE ARCHITECT and its Consultants. All rights
and privileges are reserved by the design team.
The designer's liability is limited to the extent of their fee.
These drawings shall not be duplicated without prior
written permission of The Architect.
Schedule of drawings
T -1
T-2
TITLE SHEET
EGRESS PLAN
A -1 ARCHITECTURAL FLOOR PLAN /
PARTITION &DOOR SCHEDULES
A -1.1 STOREFRONT ASSEMBLY / MISC. DETAILS
A -1.2 STOREFRONT ELEVATION /
FLOORING PLAN
A -2 INTERIOR ELEVATIONS /
FINISH SCHEDULES
A -3 REFLECTED CEILING PLAN /
LIGHT FIXTURE SCHEDULE
MISCELLANEOUS DETAILS
FIXTURE PLAN
NOTES AND SPECIFICATIONS
A -4
F -1
N-1
P-1
M-1
M -2
M -3
E -1
E -2
E -3
PLUMBING PLAN AND SPECIFICATIONS
MECHANICAL PLAN
SPRINKLER PLAN
MECHANICAL SPECIFICATIONS
ELECTRICAL LIGHTING PLAN
ELECTRICAL POWER PLAN
ELECTRICAL SPECIFICATIONS
& SCHEDULES
Store Data (FOR STORE USE ONLY)
AREA DISTRIBUTION
PLAN DESIGNATION QUANTITY PERCENTAGE OF AREA
1. GROSS LEASED AREA 3,631 S.F. 100.0 %
2. SALES AREA 3,142 S.F. 86.5 %
3. STOCKROOM 345 S.F. 9.5 %
4. TOILET ROOM 62 S.F. 1.7 %
5. EGRESS CORRIDOR 82 S.F. 2.3 %
APPROVED P!
io..r 77 :: :.ANGED, MODIFIED OR ALTERED • ,,..f.
WITHOUT AUTHORIZATION FROM THE BIPLONG
Or, "IC :AL, ALL WORK SHALL BE DCNE IN
ACCORDANCE WITH T lE APPROVIB3 PLANS AND
ISL `"TTOF,E''D'
--'�'��•• • .NaPL TIOP :a
Key Plan
MOVIES
N.T.S.
NORDSTROM
MACY'S
SEARS
I_ J
REVIEWEP�CE
CODE
70 - NEC
NFPA
SCOPE OF WORK:
THIS PROJECT IS A NON— STRUCTURAL TENANT FIT UP OF AN NEW SPACE WITHIN
WESTFIELD SOUTH CENTER. WORK SHALL INCLUDE THE CONSTRUCTION OF NEW
INTERIOR PARTITIONS, DOORS, CEILINGS, LIGH11NG, AND THE INSTALLATION OF ALL
RELATED FIXTURES AND FINISHES. NEW HVAC SYSTEM AND ACCESSIBLE TOILET
ROOM ARE REQUIRED. SEE DRAWINGS FOR ADDITIONAL INFORMATION. ALL WORK
SHALL COMPLY WITH THE APPLICABLE CODES AS NOTED ON THIS DRAWING.
Project. .Information
BUILDING DEPARTMENT:
City of Tukwila Department of Community Development
Contact: Dave Larson Phone: (206) 431 -3678
6300 South Center Blvd #100 Fax: (206) 431 -3665
Tukwila, WA 98188
APPLICABLE AND MODEL CODES:
International Building Code 2006*
National Electrical Code 2005*
International Mechanical Code 2006*
Uniform Plumbing Code 2006
International Fire Code 2006*
ANSI -117 -1 2003*
ADA Guidelines
* with the WA State Building Codes Amendments
And all accumulative supplements thereof
WA State Energy Code
CODE ANALYSIS:
USE GROUP:
CONSTRUCTION TYPE:
SEISMIC ZONE:
FIRE SUPPRESSION:
LIVE LOAD:
M — MERCANTILE
2B UNPROTECTED,NON — COMBUSTIBLE,
CLASS D
AUTOMATIC SPRINKLER SYSTEM
100 PSF
MEANS OF EGRESS /OCCUPANCY LOAD
SEE SHEET T -2 FOR ADDITIONAL INFORMATION
NOTE:
SPRINKLER AND FIRE ALARM WORK TO BE PERFORMED
UNDER SEPARATE PERMIT. ENGINEERED DRAWINGS TO BE
SUBMITTED SEPARATELY.
NOTE:
MAXIMUM NUMBER OF EMPLOYEES ON SITE AT ANY
ONE TIME IS 4. SPACE IS LOCATED WITHIN 300 FT
OF PUBLIC ACCESSIBLE RESTROOMS.
f.y.e.
SPACE # 2110
LEVEL 2 OF 3
3,631 SQ. FT.
FILE -QPY
Permit No.
jo
Plar review approval Is abject to errors and on1
Approval of construction documents does not auU
the violation of any adopted code or ordinance. R
of approved Field py and cordtions is awl±
By
Dal sp„ jai
FULLY
City of Tukwila
BUILDING DIVISION
REVISIONS
Pb changes shall be made to the scope
of work without prior approval of
Tukwila Building Division
NOTE: Revisions will require ? new pion suhrni ?'11
and rra.' n1P. "1
SPRINKLERED
' SEPARATE P REP MIT
REQUIRED FOR:
eMechardcal
❑rElechical
I� Plumping
itr Gas Piping
I City of Tukwila
3UfLDING DIVISION
Southcenter Mall
Space # 2110
2636 Southcenter Mall
Seattle, : A 98188
Key to Divisions of Work
FURNISHED I
INSTALLED
CSI C
CSI o
SHEET °
DESCRIP11ON /NOTES n
a &
~1-OM1 -
CC
° ¢
¢ u
Qa 1- 0
00 CONTRACT REQUIREMENTS
1 Bonds(if required) 0
00600 T
T -1 P
Payment /Performance Bond shall •
•
2 Insurance 0
00650 T
T -1 P
Provide Certificates •
•
01 GENERAL
1 Permits and Fees 0
01000 T
T -1 P
Per Scope of Work •
•
2 Inspections 0
01000 T
T -1 C
Comply with Local Procedures •
•
3 Barricade 0
01100 T
T -1 I
If Required •
• 0
0
4 Temporary Electrical 0
01500 T
T -1 I
If Required to Finish Work •
• 0
0
5 Temporary Telephone 0
01510 T
T -1 I
If Required •
• 0
0
02 SITE WORK
1 Selective Demolition 0
02070 A
A -1 F
For Rear Egress Door 0
0 0
0
03 CONCRETE
1 Concrete slab A
A -1 0
0
2 Reserved
04 MASONRY, .
.
1 Reserved
05 METALS
1 Misc. Metals 0
05000 A
A -1 S
See Technical Specification on N -1 0
0 0
0
2 Light Gauge Framing 0
05400 A
A1,N1 S
See Partition Schedule Sheet A -1 0
0 0
0 0
0
3 Metal Furring Channels 0
05000 A
A -1 I
If Required 0
0 0
0
4 3/4'x3/4" Wall Angle 0
05000 A
A -2 S
Slatwall Trim,See Detail Sheet A -4 0
0 0
0
5 1 "x1" Wall Angle 0
05000 A
A -1 S
Sales Area Columns 0
0 0
0
6 Metal U— Channel 0
05000 A
A -1.1 S
Storefront 0
0 0
0
06 WOCO AND PLASTICS
1 Rough Carpentry 0
06100 A
A -1 S
See Technical Specification on N -1 •
• 0
0
2 Finish Carpentry 0
06200 A
A -1 S
See Technical Specification on N -1 0
0
3 Toggle Bolts 0
06200 A
A -1 S
See Technical Specification on N -1 •
•
4 Misc. Wood Trim 0
06220 A
A -2 •
•• 0
0
1/A 5 Particle Board Valance 0
06220
6 Plastic Laminate 0
06240 A
A2,F1 1
1 Fixtures •
• 0
0 0
0
7 Hardboard Panels 0
06255 A
A-2 P
Prefinished 0
0 0
01
(Slatwall)
07 THERMAL/MOISTURE
1 00 40 00 O!
Contract Requirements
00002 — PROJECT DIRECTORY
LANDLORD'S REPRESENTATIVE:
Westfield Corporation Inc.
Contact: Josh Kimmel
11601 Wilshire Blvd 12th Floor
Los Angeles, CA 90025
TENANT:
Trans World Entertainment Corp.
Contact: Allison Rivers
38 Corporate Circle
Albany, NY 12203
Phone: (310) 893 -4761
FAX: (310) 575 -5991
Phone: (518) 452 - -1242, Ext. 7489
FAX: (518) 452 -0511
TENANT'S COORDINATOR:
Bay Planning Company, Inc.
Contact David M. Sorgman
25 Mathewson Drive, Suite 200
Weymouth, MA 02189
Phone: (781) 331 -4000
FAX: (781) 335 -2115
SUBCONTRACTOR:
Subcontractors are those individuals and /or Companies
providing services, products and portions of the Work,
described in the technical drawings and specifications,
under direct contract to the Tenant's Contractor.
Requirements
01000 — GENERAL
�./ The Tenant's Contractor and all Subcontractors shall perform
their Work according to the following:
EXISTING CONDITIONS
A. Prior to submitting bid proposals, the Tenant's Contractor
and each Subcontractor shall visit the proposed space
and make themselves familiar with all existing conditions,
take field measurements and record all information needed
to provide a complete scope of Work.
B. Notify the Tenant immediately of conditions which may
contribute to unnecessary, excessive costs.
C. No additional compensation will be paid by the Tenant
for disputes which result from a
lack of familiarity with the existing conditions.
01035 — MODIFICATION PROCEDURES
SUBSTITUTIONS & CHANGES
D. DO NOT substitute materials, equipment or methods
unless such substitution has been approved specifically in
writing by the Tenant.
E. Notify the Tenant immediately by telephone of any hidden,
unforeseen conditions and any requirements imposed by the
Landlord which impact the Work.
Confirm all notifications and action required in writing
within 24 hours of the event.
F. Milestone date changes must be made in writing by Tenant.
01040 — COORDINATION
G. The Tenant's Contractor and each Subcontractor shall be
thoroughly familiar with the Work shown on the drawings
and on the other Contract Documents.
H. Each Subcontractor shall coordinate their Work with that of
others and be aware of all Related Work to be performed
by others, via the Tenant's Contractor.
01060 -- REGULATORY REQUIREMENTS
1. Comply with all applicable National, State and Local codes.
See Project Information on this sheet.
01100 — SPECIAL REQUIREMENTS
J. NEW STORE CONSTRUCTION
K. WRITTEN DAILY JOURNAL shall be maintained
L TELEPHONE shall be provided on site by Tenant's Contractor.
M. DESIGNATE A SUPERINTENDENT for the duration of the Project
and submit his /her name to the Tenant.
N. Work shall be completed in a timely manner, consistent with
the approved CONSTRUCTION SCHEDULE.
P. The Tenant's Contractor shall be responsible for receiving
and maintaining in good condition all millwork, fixtures and
equipment up to the Date of Substantial Completion.
Q. All Tenant material delivered to the Project shall be
checked against the Tenant's material list by the Tenant's
Contractor at the time of delivery. All discrepancies shall
be noted in the Receiving Report and in the Daily Journal,
and the Tenant's Contractor shall immediately notify the
Tenant of same. All Shortages occurring after receipt of
goods shall be charged back to the Tenant's Contractor.
R. CLEA N I N G:
a. Each Subcontractor shall clean his /her Work and remove
all trash, debris, packing, etc... resulting from that Work.
b. Final cleaning shall be done by a professional cleaner.
See specification section 01710 — FINAL CLEANING
01340 — SUBMITTALS
S. Product samples, manufacturer's data and shop drawings
shall be submitted to Comprehensive Development Corp.
for review prior to fabrication or start of work.
01700 -- CONTRACT CLOSE —OUT
T. Substantial Completion is the date certified by Tenant's Project Manager
on which the Work or designated portion thereof is sufficiently
complete so the Tenant may occupy the same for the
intended purpose.
U. Provide the following for close—out
1—Daily Journal
2— Operation and Maintenance Data
3 —Keys
4 —Spare Parts, Materials and Stock
5— Certificate of Inspection /Occupancy
6— Certificate of Insurance
7— Evidence of Payrnent and Release of Liens
8 —List of Subcontractors, Vendors and Suppliers
Works, aiming Division 9 —Final Statement of Account
ert
PERMIT NUMBER V. Construction codes and keys must be turned into TWEC with the General
Contractor's final payment request or the contractor will be charged $70.
R""
CITY or i ur,vr.w
MAP 0 3 2008
PERMIT CENTER
NOTE:
T.G.C. TO FIELD VERIFY EXISTING CONDITIONS PRIOR
TO CONSTRUCTION AND INFORM THE TENANT'S
PROJECT MANAGER AND THE ARCHITECT OF ANY
DISCREPANCIES IMMEDIATELY.
NOTE:
T.G.C. TO FIELD VERIFY CONDITION OF ALL ITEMS
DESIGNATED TO REMAIN OR BE REUSED AND INFORM
TENANT'S PROJECT MANAGER AT THE START OF
CONSTRUCTION OF ANY ITEMS IN NEED OF REPAIR.
REVISIONS:
DATE: 2/20108
JOB NO: PY- 06 -01 -D
STORE NO: 124
TWEC PR #: 28°x11
CHECKED: CM
LLI
LLJ
CI)
LjJ
J
PROJECT COORDINATION:
Fax: 781 -535 -2115
SHEET NUMBER
T -1
SHEET 1 OF 17
'
B
SF
A
HA -5
A
HA -5
A
HA -5
LA -11
U MN I
MEI
F
LA -11
Y
HA -9
HA -9
E
HA -9
0®
E
HA-9
SF---
HA-9
01•
Y
HA 9
SF
HA -9
Y�
HA -9
A
HA -5
A
HA -5
EM
®HA-1
A
HA -5
A
HA -5
A
HA -5
®HA-1
II
EM
''HA -1
N/L
A
HA -3
A
HA -3
A
HA -3
A
HA -1
A
HA -3
A
HA -3
HA A -3
A
HA -3
N/L
HA-1
EM
1
®H 1 H
II
E
J1
N/L
A
HA -5
A
HA -1
A
HA -5
•
N/L
A
HA -5
A
HA -5
A
HA -1
A
HA -5
A
HA -5
•
EM
® HA -1
® EM
Hit-1
EM
® HA -1
Asa
D1
LA -5
HAr5
0
D1
LA -9
0
D1
LA -5
A
HA -3
A
HA -3
A
HA -3
A
HA-
I
A
HA -3
A
HA -3
VERIFY ALL EXISTING CONDITIONS IN THE FIELD.
MARK
NOTE;
THE ELECTRICAL CONTRACTOR SHALL PROPERLY
BALANCE ALL BRANCH CIRCUITS BETWEEN THE
PHASES OF THE SYSTEM, REGARDLESS OF
CIRCUITING INDICATED.
COIL V
NOTE;
THE LOCAL BUILDING DEPARTMENT REQUIRES A
MINIMUM OF ONE FOOT CANDLE OF EMERGENCY
LIGHTING THROUGHOUT THE ENTIRE TENANT SPACE.
AMP
DEMOLITION;
THE ELECTRICAL CONTRACTOR SHALL REMOVE ALL
EXISTING ELECTRICAL EQUIPMENT, LIGHT FIXTURES,
DEVICES, CONDUIT AND WIRE, ETC.. NOT BEING
REUSED.
STOREFRONT
SIGN
& UGHTS
ALL WORK AND MATERIAL SHALL BE IN ACCORDANCE
WITH THE LANDLORD'S
MECHANICAL /ELECTRICAL CRITERIA.
ALL CONTRACTORS SHALL OBTAIN A COPY OF THE
CRITERIA FROM THE LANDLORD'S TENANT
COORDINATOR, OR MALL OPERATIONS MANAGER
AND BECOME FAMILIAR WITH THE REQUIREMENTS
CONTAINED WITHIN PRIOR TO BIDDING THE JOB.
WHERE LANDLORD'S REQUIREMENTS CONFLICT WITH
CODES OR ORDINANCES THE STRICT .S1
INTERPRETATION SHALL APPLY.
EXIT AND EMERGENCY LIGHTING SHALL BE PER
REQUIREMENTS OF LOCAL GOVERNING CODES.
BATTERY PACKS FOR EXIT AND EMERGENCY LIGHTS
MUST BE REMOTE OR RECESSED. PAINT EXPOSED
SURFACES TO MATCH ADJACENT FINISH.
NOTE;
FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED
UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE
SUBMITTED SEPERATELY.
NOTE;
ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND
NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE
PERFORMED UNDER SEPERATE PERMIT.
NOTE;
ALL SPEAKER WIRING SHALL BE FURNISHED AND
INSTALLED BY TENANTS VENDOR.
A
HA -3
A
HA -3
A
HAI3
J -BOX FOR NEON LIGHTING ON
CIRCUIT LA -3, VIA TS1. MOUNT NEON
TRANSFORMER AS REQUIRED.
D1 0
LA -9
D1 0
LA-5
O D1
L4 -5
0
D1
LA -9
0
D1
LA -5
EM
HA -1
D1 0
LA -9
EM
HA--1
ED O D1
LA -5
HA-�3
L
D1
LA -9
VOLTARC SPARKLING BLUE NEON ACCENT
STRIP W /NATURAL ALUMINUM PANEL ON
FACE OF SOFFIT, FURNISHED AND INSTALLED
BY TENANTS SIGN CONTRACTOR. SEE DETAIL
2/A1.1 FOR ADDITIONAL INFORMATION.
a
D1
LA -5
0
D1
LA -9
0
D1
LA -5
O D1
0
I 0
0
II
LA -9
LIGHTING PLAN
0 1 2 4
CONTACTOR SCHEDULE
MARK
LOAD
CONTROL
COIL V
UNE V
POLES
AMP
CIRCUITS
C1
STOREFRONT
SIGN
& UGHTS
TS1
120
120
8
20
LA- 113,10,12
C2
SALES LTG
MC1
120
120/277
4
20
HA -3
LA -5
C3
SALES LTG
MC2
120
120/277
4
20
HA -5
LA -9
LA-34
NEUTRAL HOT
TIME SWITCH (TS1)
C1
•
SEE CONTACTOR SCHEDULE
FOR ADDITIONAL INFORMATION.
MC1
MC2
CONTACTOR CONTROL DETAIL
NOT TO SCALE
C2 r --
STOREFRONT UGHTS
SIGN & SHOW.
WINDOW REC.
SALES AREA LIGHTS
SALES AREA LIGHTS
1 /4" = 1 -0"
8 FEET
J -BOX FOR NEON LIGHTING ON
CIRCUIT LA -3, VIA TS1. MOUNT NEON
TRANSFORMER AS REQUIRED.
LIGHTING PLAN KEY NOTES ®
1. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD
SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT.
2. CIRCUIT EXHAUST FAN /LIGHT COMBINATION AS INDICATED. FAN AND LIGHT SHALL BE CONTROLLED BY
THE SAME SWITCH.
3. INSTALL WATT STOPPER #WS -120 -W OCCUPANCY SENSOR. SENSOR SHALL BE FURNISHED BY
LIGHTING VENDOR. MAKE FINAL CONNECTIONS.
4. INSTALL WATT STOPPER #C1 -200 CEILING MOUNTED OCCUPANCY SENSOR. SENSOR SHALL BE
FURNISHED BY LIGHTING VENDOR. MAKE FINAL CONNECTIONS.
5. INSTALL WATT STOPPER POWER PACK. POWER PACK SHALL BE FURNISHED BY LIGHTING VENDOR.
MOUNT ON WALL ABOVE CEILING IN AN ACCESSIBLE LOCATION. PROVIDE ALL NECESSARY ITEMS FOR A
FULLY FUNCTIONING SYSTEM.
6. PROVIDE 11MESWITCH: PARAGON MODEL 7000 SERIES OR EQUAL WITH 7 DAY 24 HOUR SCHEDULE
FORMAT, MIN. (4) N.O. 20 AMP 120/277 VOLT CONTACTS 120 VOLT COIL AND SPRING WOUND RIDE
THROUGH SWITCH TO CONTROL STORE FRONT SIGN AND LIGHTING OR CONTACTORS AS INDICATED.
7. PROVIDE LIGHTING CONTACTOR(S): ASCO 917 SERIES OR EQUAL WITH 120 VOLT COIL MINIMUM 20 AMP
120/277 VOLT CONTACTS ELECTRICALLY OPERATED AND MECHANICALLY HELD, 3 -WIRE CONTROL SEE
CONTACTOR SCHEDULE FOR ADDITIONAL INFORMATION. CONTACTOR(S) CONTROLLED VIA TIMESWITCH
AND /OR MOMENTARY CONTACT SWITCH AS INDICATED. SEE CONTACTOR CONTROL DETAIL 2/E-1.
8. EMERGENCY LIGHTING AND EXIT SIGN SHALL BE WIRED AHEAD OF SWITCHING DEVICE.
9. CENTER TYPE "D1" LIGHT FIXTURES BETWEEN GLAZING CHANNEL AND GYPSUM BOARD SOFFIT.
10. EXIT SIGN TO BE MOUNTED, CENTERED ABOVE DOOR AT 7' -6" AFF TO CENTERLINE OF FIXTURE.
11. EXIT SIGN TO BE MOUNTED ON FACE OF SOFFIT SO AS NOT TO BE VISIBLE FROM MALL COMMON
AREA.
12. MASTER SWITCH LOCATION: PROVIDE (2) MASTER SWITCHES FOR CONTROL OF CONTACTORS. SEE
CONTACTOR SHEDULE ON THIS SHEET. MOUNT ON WALL BEHIND CASHWRAP. VERIFY EXACT LOCATION
WITH ARCHITECT.
NOTE: 2006 IBC — Sec. 1006
Provide an average of one
foot - candle illumination at the
floor along the entire egress
pathway and exit discharge
PL
LA -1
PL
LA -1
LA D -1 9
LA D -1
0
LA -1
VOLTARC SPARKING BLUE NEON ACCENT
STRIP W /NATURAL ALUMINUM PANEL ON
FACE OF SOFFIT, FURNISHED AND INSTALLED
BY TENANT'S SIGN CONTRACTOR. SEE DETAIL
2/A1.1 FOR ADDITIONAL INFORMATION.
CEILING MOUNTED LIGHT FIXTURES
SYMBOL
DESCRIPTION
MFR.
STYLE/
CAT. NO.
VOLTS/
LAMPS
COMMENTS
N/A
N/A
Fluorescent
Light Fixture w/
9 Cell White
Parabolic Lens
Surface Mounted
Single Circuit
Track System
(Silver)
Incandescent
Gimbal Ring
Open Back
MonopointTrack
Head (Silver)
4" Recessed
Incandescent
Downlight
8" Recessed
Incandescent
Downlight
Exit Light Fixture
with 90 Minute
Battery Backup
Recessed
Emergenc g
with 90 MinuLite ht
Battery Backup
Combination
Fan / Light
100 CFM
9" Recessed
Compact Fluor.
Downlight
4' Fluorescent
Strip Fixture
Surface Mounted
Emergency Light
with 90 Minute
Battery Backup
Designates
Night —light
LIGHTOLIER
JUNO
JUNO
JUNO
JUNO
ATUTE
DUAL —UTE
NUTONE
JUNO
SIMKAR
ATIJTE
PLA2G9WP
3FT277X3
T2NA,
T4NA,
T6NA,
T8NA
V689NA
TC44/
447CWH
MC8P3870/
8838CWH
PNLRU
E2-2R
8663P
CH9 226/
32/42T—
950CWH
CH -232
PCI -10
3 PLL40 /35K
77 Volts
3) U -40W
120 Volts
120 Volts
75W PAR 30
NFL
120 Volts
50W MR16 FL
EXN
120 Volts
70W PAR38
MH FL
277 Volts
(2) 15T6
12W
277 Volts
8W
120 Volts
1 -100W
120 Volts
(2) 42W
35K
277 Volts
2 —F32T8
TL735
120/277 V
8W
Sales Area
See Note 1 Below
Sales Area
(Storefront Soffit)
Sales Area
Soles Area
Stockroom
Egress Corridor
Sales Area
Toilet Room
Storefront Soffit
Stockroom
Egress Corridor
Stockroom, Toilet Room
Egress Corridor
ril2'x2'
••
LIC1
OD
Oi,
0
Si
E
EM
F
■
■
0PL
SSF
Y
d
NOTE 1:
ALL FLUORESCENT LAMPS SHALL BE CHROMA 30 (UNLESS OTHERWISE NOTED).
NOTE 2
T.G.C. TO FIELD VERIFY EXACT LOCATION & POSITIONING OF TRACK HEADS WITH TENANTS
PROJECT MANAGER PRIOR TO INSTALLATION.
NOTE 3:
NEON LIGHTING IS TO BE 13mm DOMESTIC GLASS CUSTOM FIT. FABRICATOR TO PROVIDE
SHOP DRAWINGS OF THE PROPOSED NEON LIGHTING, SHOWING LIGHT FIXTURES, MOUNTING
AND TRANSFORMERS FOR APPROVAL LOCATE TRANSFORMERS ABOVE CEILING IN AN
ACCESSIBLE LOCATION. NEON COLORS TO BE AS DESIGNATED ON CEIUNG PLAN. ALL
HOUSINGS TO BE RECESSED BEHIND SOFFIT WALL OR ABOVE CEILING. SEE DETAILS FOR
MOUNTING LOCATION OF NEON.
NOTE;
SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF
LIGHT FIXTURES. IF DISCREPANCIES EXIST BETWEEN THIS SHEET AND ARCHITECTURAL
REFLECTED CEILING PLAN, ARCHITECTURAL REFLECTED CEILING PLAN WILL TAKE
PRECEDENCE.
DATE: 2/20/08
n
O
Z
m
O
STORE NO: 1248
U m
DRAWN BY:
CHECKED BY:
E
0
U
w C °c
O '. *l 2+
Cn .
§Vn
o .0
to ▪ m
W
0
P.-
CITY:31- 1 Una v..
MAP 032008
PERMIT CENTE
SHEET NUMBER
E -1
SHEET 15 OF 17
INSTALL AT
P.O.S. CABINET.
0 UNE #2
4-28
IG
0 V
CP)
LA- 14
LA-14
LA
18"
1
LA-16
LA-30
\
FOLDING
TABLE
VAV-1
"C. /
(2)1"C.
RJ11-
-RJ14 -
RJ45
7 o i
LA-15 i
LA-15
LA-15
LA-14
LA
32
NAME
VOLT/
PHASE
9ff
CON DUIT/
WIRE
CONTROL
STARTER
PNL
CCT.
NO.
DISC.
SWITCH
FUSE
SIZE
NOTES
HP
KW
VAV-1
00
0
-
LA-14 LA-14 LA-14
LVS UNIT (TYP.)
00
41)
-64 LA-32
3:(
LA46
oo
LA46
LA68
00
LA48
LA- 8
11102>
1 LA-14-
U.
LJir
17 1
11110Imm • im • im El is • num mammo is am 116
LA-_l8
I
mg • im-a-a7s-rlogrio,
LA-18
NOTE:
TENANT E.C. TO SPECIFY COLORS OF ELECTRICAL
RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND
CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF
ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION.
NOT;
FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED
UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE
SUBMITTED SEPERATELY.
NOTE;
ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND
NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE
PERFORMED UNDER SEPERATE PERMIT.
EEL
ALL SPEAKER WIRING SHALL BE FURNISHED AND
INSTALLED BY TENANT'S VENDOR.
EQUIPMENT SCHEDULE
i
NAME
VOLT/
PHASE
LOAD
CON DUIT/
WIRE
CONTROL
STARTER
PNL
CCT.
NO.
00
LA48
LA- 8
11102>
1 LA-14-
U.
LJir
17 1
11110Imm • im • im El is • num mammo is am 116
LA-_l8
I
mg • im-a-a7s-rlogrio,
LA-18
NOTE:
TENANT E.C. TO SPECIFY COLORS OF ELECTRICAL
RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND
CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF
ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION.
NOT;
FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED
UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE
SUBMITTED SEPERATELY.
NOTE;
ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND
NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE
PERFORMED UNDER SEPERATE PERMIT.
EEL
ALL SPEAKER WIRING SHALL BE FURNISHED AND
INSTALLED BY TENANT'S VENDOR.
EQUIPMENT SCHEDULE
NO.
NAME
VOLT/
PHASE
LOAD
CON DUIT/
WIRE
CONTROL
STARTER
PNL
CCT.
NO.
DISC.
SWITCH
FUSE
SIZE
NOTES
HP
KW
VAV-1
VAV BOX #1
277/480/3
1/3
5.0
3/4C.-4#12 CU.
DIV.15
DIVA 5
HA
8,10,12
30A/3P
15
SEE KEYNOTE
VAV-2
VAV BOX #2
277/480/3
1/3
5.0
3/4C.-412 CU.
DIVA 5
DIV.15
HA
14,16,18
30A/3P
15
SEE KEYNOTE
WH-1
WATER HEATER #1
120/1
--
1.7
3/4"C-2#12 - CU
DIV. 15
-
LA
13
-
-
SEE KEYNOTE
TYPE fr
FAN/UGHT COMBO.
120/1
--
0.2
3/4"C-2#12 - CU
WALL SW.
--
LA
11
--
-
SEE KEYNOTE ON SHEET El
POWER PLAN KEY NOTES 0.
1. PROVIDE TELEPHONE BACKBOARD AS SPECIRED.
2. PROVIDE TELEPHONE OUTLET, CONDUIT AND CABLE. SEE DETAIL 3/E-3.
3. LOCATION OF ELECTRICAL SERVICE EQUIPMENT. SEE POWER RISER DIAGRAM AND PANELBOARD
SCHEDULES ON SHEET E-3. MAINTAIN REQUIRED CODE CLEARANCES OF ALL ELECTRICAL EQUIPMENT.
4. NOT USED.
5. ALL CONDUIT AND WIRING AT CASHWRAP SHALL BE CONCEALED IN CASEWORK. COORDINATE WITH
CASEWORK MANUFACTURER.
6. PROVIDE J - BOX WITH DISCONNECT SWITCH IN ACCESSIBLE CONCEALED SPACE FOR STOREFRONT SIGN.
FIELD VERIFY EXACT LOCATION. SEE SPECIFICATION ON SHEET E-3 FOR ADDITIONAL INFORMATION.
7. PROVIDE FLUSH DUPLEX RECEPTACLE IN SHOW WINDOW CEIUNG. COLOR SHALL MATCH ADJACENT
SURFACE.
8. ISOLATED GROUND CIRCUITS SHALL BE INSTALLED IN SEPARATE CONDUIT FROM NORMAL POWER
CIRCUITS. EACH IG CIRCUIT SHALL HAVE A. SEPARATE NEUTRAL AND INSULATED GROUND WIRE. THE
GROUND WIRE SHALL BE CONTINUOUS BACK TO THE PANEL AND CONNECTED TO THE GROUND BUS
WITHIN THE PANEL IG RECEPTACLES SHALL BE HUBBELL NO. IG-5362, OR APPROVED EQUAL.
9. CORE BORE FLOOR SLAB AND INSTALL CONDUIT WITH PULLWIRE. PROVIDE BUSHING AT EACH END.
PATCH AND REPAIR FLOOR TO MATCH EXISTING CONDMON. COORDINATE WORK WITH MALL OPERATIONS
MANAGER.
10. SEE EQUIPMENT SCHEDULE FOR MECHANICAL EQUIPMENT INFORMATION. COORDINATE EXACT LOCATION
WITH MECHANICAL CONTRACTOR.
11. PROVIDE A 1 1/2" CONDUIT FOR DATA UNES FROM CASHWRAP. COORDINATE WITH TENANT'S PROJECT
MANAGER.
12. PROVIDE DEVICES SHOWN IN BACKROOM. COORDINATE WITH TENANT'S PROJECT MANAGER.
13. PROVIDE A DUPLEX RECEPTACLE AND LOW VOLTAGE JUNCTION WITH 1 C. WITH PULL STRING, STUB UP
ABOVE CEIUING IN ACCESSIBLE LOCATION. VERIFY EXACT MOUNTING LOCATION WITH ARCHITECT PRIOR
TO ROUGH-IN.
14. NOT USED.
15. PROVIDE 120 VOLT CONNECTION TO SENSORMATIC SYSTEM. COORDINATE EXACT REQUIREMENTS WITH
TENANT'S PROJECT MANAGER.
16. NOT USED.
17. NOT USED.
18. PROVIDE DEVICE IN CEIUNG FOR LOSS PREVENTION REQUIREMENT. COORDINATE WITH TENANT'S
PROJECT MANAGER.
19. ALL CONDUITS ROUTED TO FLOOR FIXTURES SHALL BE STUBBED UP AT O'-4 AFF. INSTALL BUSHING
AT TOP AND PROVIDE PULL STRING..
20. TENANT'S A/V VENDOR SHALL FURNISH AND INSTALL CEIUNG MOUNTED SPEAKERS AND RELATED WIRING
AS INDICATED ON PLAN. COORDINATE WITH TENANT'S PROJECT MANAGER.
21. PROVIDE SERVICE DOOR BUZZER SYSTEM: EDWARDS: 340-405-24VAC BUZZER, ONE (1) NEW
ANNUNCIATOR LOCATED AT THE CASHWRAP AND ONE (1) BUZZER IN THE OFFICE, 852 WEATHERPROOF
PUSHBUTTON, 592 TRANSFORMER. BUZZER SYSTEM WIRE NEED NOT BE INSTALLED IN CONDUIT
UNLESS REQUIRED BY LANDLORD OR LOCAL AUTHORITY.
22. RECEPTACLES IN THE SALES AREA SHALL BE LOCATED 12'-0" ON CENTER. FIELD VERIFY EXACT
LOCATION.
23. NOT USED.
24. PROVIDE FLUSH MOUNTED J -BOX AT 181. AFF AT LVS STATION IN BACKROOM. J -BOX SHALL HAVE (2)
1" CONDUITS STUBBED UP ABOVE CEIUNG TO ACCOMODATE LOW VOLTAGE WIRING FROM SALES AREA
LVS STATION(S). COORDINATE WITH TENANT PROJECT MANAGER.
25. NOT USED.
26. NOT USED.
27. ELECTRICAL CONTRACTOR SHALL PROVIDE A 3/4" CONDUIT WITH PULLSTRING STUBBED UP ABOVE
CEIUNG FOR LVS WIRING BY TENANT. CONDUIT SHALL BE CUT FLUSH TO FACE OF WALL AT 18"
A.F.F., AND NIPPLE SHALL BE INSTALLED.
28. PROVIDE RECEPTACLE AND UGHT SWITCH AT VAV BOX UNITS. PROVIDE PORCELAIN SOCKET WITH (1)
60WA19 LAMP, MOUNT NEAR ACCESS PANEL VERIFY EXACT LOCATION WITH MECHANICAL CONTRACTOR.
POWER PLAN
.22 H l
4
8 FEET
1 /4"
ALL CONDUITS AND CABLE PROVIDED BY ELECTRICAL CONTRACTOR.
NOTE:
ALL CONDUITS TO RUN WITHIN FIXTURE FROM DEMISING WALL
ADJACENT TO CASHWRAP. SLAB CORE BORING NOT REQUIRED.
NOT
SEE FLOOR PLAN FOR CORRECT ORIENT TION.
NOTE:
VERIFY CASH WRAP ELECTRICAL REQUIREMENTS
WITH TENANT PROJECT MANAGER.
1 1/2" CONDUIT WITH PULLSTRING
FROM POS CABINET WITHIN
STOCKROOM FOR DATA UNE.
TENANT'S VENDOR TO PULL DATA
CABLE.
3/4* CONDUIT WITH PULLSTRING FOR
TELEPHONE SYSTEM. EXTEND TO
TELEPHONE BACKBORAD IN
STOCKROOM.
DEDICATED DUPLEX OUTLET
IN AN ACCESSIBLE
LOCATION FOR FUTURE
LOSS PREVENTION.
(1) 1 1/2" CONDUIT WITH
PULLSTRING FOR A/V EQUIPMENT.
RUN WITHIN MILLWORK AND STUB
ABOVE CEIUNG TO AN ACCESSIBLE
LOCATION. BUSH TOP END.
vi
LA-8 41,1-A-8
(2) 3/4" CONDUIT AT CASHWRAP
AND PAN ELBOAR D:
(1) CONDUIT FOR IG RECEPTACLES
CLEAN POWER AND
(1) CONDUIT FOR RECEPTACLES
DIRTY POWER. RUN CONDUIT
WITHIN MILLWORK OF CASHWRAP.
IG
UNES #1 AND 2
FOR TELEPHONE UNES
2 UNE RJ -141
TELEPHONE JACK.
RJ-45 TELEPHONE
JACK FOR DATA UN ES
ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX IN
CASH WRAP FOR ALTRONIX ALTV248 CAMERA POWER
SUPPLY UNIT. COORDINATE NUMBER AND LOCATION OF
CAMERAS WITH TENANT'S PROJECT MANAGER
ELDS 00-2.014
CASH WRAP POWER PLAN
CITY 01 I ur,v...
MAP 0 3 NM
PERMIT CENTER
■11.11110/
t.)
C.*
■74
0
z
0
STORE NO:
C.)
C.) CO
DRAWN BY:
CHECKED BY:
PROJECT COORDINATION:
. . •
111
..\••■•\ 1••••■•■•■\NNV:W.•
RI 1M
&tem
1-111•1
•
SHEET NUMBER
E-2
SHEET 16 OF 17
H
ELECTRICAL SPECIFICATIONS
16000 - GENERAL PROVISIONS
0.01 PERFORMANCE: ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK
SPECIFIED, INDICATED AND REQUIRED UNLESS OTHERWISE NOTED,
INCLUDING FINAL CONNECTIONS, IN A WORKMANUKE MANNER USING
WORKERS SKILLED AND EXPERIENCED IN THE TRADE.
0.02 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIMS FOR EXTRAS
RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS SHALL NOT
BE ALLOWED OR APPROVED.
0.03 JOB SITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR
CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND
PROPERTY DURING PERFORMANCE OF THE WORK.
0.04 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECESSARY FOR COMPLETE
AND FULLY FUNCTIONAL INSTALLATION.
0.05 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSER, BONDING, AND
INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS
REQUIRED.
0.06 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE
CHARGES.
0.07 COORDINATION: CONFORM TO GENERAL CONSTRUCTION CONTRACT
DOCUMENTS EXCEPT AS MODIFIED HEREIN. REFER ALSO TO STRUCTURAL
AND MECHANICAL CONTRACT DOCUMENTS. COORDINATE ALL WORK WITH
OTHER TRADES.
0.08 ROOF PENETRATIONS: COORDINATE WITH LANDLORD.
0.09 MECHANICAL SUBSTITUTIONS: INVOICE MECHANICAL CONTRACTOR, NOT
TENANT, FOR COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL
EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE
INDICATED.
0.10 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED
BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER
OPERATION AND WITHIN THE INTENT OF THE CONTRACT.
0.11 REFERENCE STANDARDS: COMPLY WITH NEC, AND APPUCABLE STANDARDS
OF NFPA, ANSI, NEMA, AND UL, EXCEPT AS SUPERSEDED BY LOCAL
AUTHORITY-. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED
CODE MINIMUM REQUIREMENTS.
0.12 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF LOCAL
CODES, LANDLORD, SERVING UTILITY, AND THE LOCAL AUTHORITY HAVING
JURISDICTION. SECURE APPROVAL OF INSTALLATION BY LANDLORD, LOCAL
AUTHORITY, AND OTHERS AS REQUIRED.
0.13 SCHEDULE: ORDER EQUIPMENT WITHIN 5 DAYS OF RECEIPT OF
CONTRACT TO MAINTAIN CONSTRUCTION SCHEDULE.
0.14 TEMPORARIES: PROVIDE ALL TEMPORARY SERVICE, UGHTING AND POWER
FOR ALL TRADES AS REQUIRED. REMOVE ALL TEMPORARIES BY THE TIME
OF PROJECT COMPLETION.
0.15 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL LISTED, COMMERCIAL
GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR
ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPLIANT WITH THE
CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE
ENGINEER. COMPLY WITH CURRENT CODES.
0.16 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN
FULL ACCORD WITH MANUFACTURERS' RECOMMENDATIONS.
0.17 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER
OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED
UNDER THIS CONTRACT. VERIFY PROPER MOTOR ROTATION OF ALL
EQUIPMENT.
0.18 0 & M MANUALS: AT COMPLETION OF PROJECT, PROVIDE TO TENANT
ALL OPERATING AND MAINTENANCE MANUALS AND INFORMATION FOR
MATERIAL EQUIPMENT AND SYSTEMS INSTALLED UNDER THIS CONTRACT.
0.19 CORRECTIVE PERIOD: PROVIDE A CORRECTIVE PERIOD FROM DATE OF
FINAL ACCEPTANCE OF NOT LESS THAN ONE (1) YEAR FOR THE ENTIRE
INSTALLATION, DURING WHICH PERIOD UNCONDITIONALLY MAKE GOOD
ANY DEFECTS IN MATERIALS OR WORKMANSHIP WITHOUT COST TO TENANT.
0.20 DRAWINGS ARE DIAGRAMMATIC: VERIFY ALL DIMENSIONS AND LENGTHS,
AND ADJUST EQUIPMENT AND RACEWAY LOCATIONS TO AVOID CONFUCTS
WITH OTHER CONSTRUCTION.
0.21 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE
THESE SPECIFICATIONS.
0.22 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS
AND REQUIREMENTS.
0.23 PROJECT REQUIREMENTS: REFER TO DRAWINGS FOR PARTICULAR
PROJECT REQUIREMENTS, AS NOT ALL ITEMS SPECIFIED MAY BE REQUIRED
FOR THIS PROJECT.
0.24 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES
OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED
WORK, FAIUNG SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME.
0.25 CERTIFICATION: PROFESSIONAL ENGINEER CERTIFICATION OF THESE
DOCUMENTS DOES NOT EXTEND TO STANDARDIZED DESIGN OR
INSTALLATION GUIDELINES PREPARED BY OTHERS AND REQUIRED BY A
THIRD PARTY TO BE INCLUDED HEREON.
0.26 DEFINITIONS: THE TERMS USTED BELOW ARE DEFINED AS FOLLOWS WHEN
USED IN DMSION 16 AND ONLY DMSION 16.
A. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS,
DELIVER TO THE JOB SITE IN NEW CONDITION AND GUARANTEE
B. INSTALL RECEIVE AT THE JOB SITE, UNLOAD, STORE, SET IN PLACE,
CONNECT, PLACE IN OPERATION AND GUARANTEE.
C. PROVIDE FURNISH AND INSTALL
D. REMOVE REMOVE INSTALLATION BACK TO NEXT REMAINING POINT OF
USE.
16100 - MATERIALS
1.01 RACEWAY: CONTINUOUS SYSTEM, 1/2" MINIMUM EMT EXCEPT: 3/4"
MINIMUM RNC WITH GROUND CONDUCTOR WHERE EMBEDDED IN CONCRETE
OR MASONRY; 3/4" MINIMUM GALVANIZED RMC OR IMC WHERE EXPOSED
TO WEATHER (ALSO PERMITTED WHERE EMBEDDED IN CONCRETE OR
MASONRY); AND FMC (OR LTFMC IF WET LOCATION) FOR SHORT FINAL
CONNECTIONS TO UGHTING FIXTURES, TRANSFORMERS, AND MECHANICAL
EQUIPMENT.
1.02 IG RACEWAY: PROVIDE SEPARATE RACEWAY SYSTEM FOR IG CIRCUITS.
1.03 RACEWAY INSTALLATION: CONCEAL RACEWAY IN FINISHED SPACES. ROUTE
SQUARE WITH BUILDING ONES AND SUPPORT PER NEC. DO NOT ATTACH
TO OR PENETRATE HVAC DUCTS. MAINTAIN HEADROOM AND EQUIPMENT
AND FLUE CLEARANCE. FIRE /SMOKE - SEAL PENETRATIONS OF RATED
CONSTRUCTION.
1.04 RACEWAY ADJUSTMENTS: WHERE INDIVIDUAL HOME RUNS ARE SHOWN
FOR CLARITY, COMBINE AND ADJUST RACEWAY SIZE PER FIELD
CONDITIONS.
1.05 WIRE: TYPE THHN, COPPER ONLY, 12AWG MINIMUM, STRANDED FOR
SAWG AND LARGER. LV WIRING FOR EMERGENCY UGHTING, 10AWG
MINIMUM. USE OF ALUMINUM CONDUCTORS SHALL NOT BE ALLOWED.
1.06 COLOR CODE: COLOR CODE ENTIRE WIRING SYSTEM FROM SERVICE
DISCONNECT OR TRANSFORMER THROUGHOUT ALL BRANCH CIRCUITS AS
FOLLOWS: FOR 120/208 VOLT SYSTEM, PHASE A - BLACK, PHASE B -
RED, PHASE C - BLUE, NEUTRAL - WHITE; FOR 277/480 VOLT SYSTEM,
PHASE A - BROWN, PHASE B - ORANGE, PHASE C - YELLOW, NEUTRAL
- WHITE WITH TRACER OR GRAY; GROUNDING CONDUCTOR - GREEN.
1.07 WIRE SIZE: WHERE WIRES ARE SIZED PER 60 DEG. C TEMPERATURE
RATING FOR SIZES UP TO 1 AWG, SUBJECT TO COMPLIANCE WITH
EQUIPMENT UL USTING, AND APPROVAL OF LOCAL AUTHORITY AND
ENGINEER, SUCH WIRES MAY BE REDUCED TO 75 DEG. C RATED SIZE,
WITH RACEWAY SIZE ADJUSTED ACCORDINGLY. WIRE SIZE PER 90 DEG.
C TEMPERATURE RATING IS NOT APPROVED.
1.08 VOLTAGE DROP: FOR CONDUCTORS SIZED PER NEC ON DRAWINGS,
INCREASE SIZE BY NUMBER OF STANDARD SIZES SHOWN IN TABLE TO
COMPENSATE FOR VOLTAGE DROP. CONTACT ENGINEER FOR ASSISTANCE
IF CIRCUIT LENGTH FROM SOURCE TO LOAD EXCEEDS MAXIMUMS SHOWN.
CCT VOLTS /PH CCT LENGTH FT. UPSIZE
120/1 75 -150 1
120/1 150 -200 2
208/3 OR 277/1 150 -200 1
208/3 OR 277/1 200 -250 2
480/3 300-450 1
480/3 450 -550 2
1.09 TYPE MC CABLE: MC CABLE EQUIPPED WITH A GREEN INSULATED
GROUND PERMITTED FOR BRANCH CIRCUITS IN CONCEALED LOCATIONS
ONLY SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL
AUTHORITY.
1.10 SPUCES: SPUCE ONLY IN ACCESSIBLE JUNCTION BOXES, USING
"WIRENUT" CONNECTORS FOR BAWG AND SMALLER, OR MECHANICAL
COMPRESSION CONNECTORS WITH INSULATION KIT FOR 6AWG AND LARGER.
1.11 BOXES: NEMA 051 IN INTERIOR DRY LOCATIONS, CAST WEATHERPROOF
TYPE IN WET LOCATIONS.
1.12 WALL SWITCHES: FED SPEC W -S -896, AC GENERAL USE, 20 AMP,
120 -277 VOLT, TOGGLE HANDLE. INSTALL 48" A.F.F TO CENTER.
1.13 WALL RECEPTACLES: FED SPEC W -C -596, NEMA 5 -20R CONFIGURATION
OR AS REQUIRED. PROVIDE IG (ISOLATED GROUND) AND GFCl/WP
(GROUND -FAULT CIRCUIT INTERRUPTER) RECEPTACLES WHERE
APPROPRIATE OR INDICATED. INSTALL 18" A.F.F TO CENTER, OR AS
INDICATED.
1.14 WALL PLATES: SMOOTH PLASTIC. KITCHEN AREA STAINLESS STEEL
1.15 WALL DEVICE AND PLATE COLOR: MATCH ADJACENT SURFACE, OR AS
DIRECTED BY ARCHITECT. PROVIDE ORANGE IG RECEPTACLES.
1.16 MANUFACTURED WIRING SYSTEMS: PERMITTED FOR BRANCH CIRCUITS
SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY.
1.17 GROUNDING: PROVIDE CONTINUOUS, PERMANENT, AND EFFECTIVE
GROUNDING SYSTEM. GROUND SEPARATELY DERIVED SYSTEMS TO
NEAREST EFFECTIVELY GROUNDED BUILDING STRUCTURAL STEEL
16400 - EQUIPMENT
4.01 DISCONNECT SWITCH: NEMA KS1, GENERAL DUTY, 3 POLE, S/N IF
NEUTRAL IS PRESENT, NEMA 3R ENCLOSURE IF OUTDOORS, LOCK -OFF,
NON- FUSIBLE UNLESS INDICATED WITH FUSES.
4.02 DRY -TYPE TRANSFORMER: NEMA ST20, 480:208Y120 CONNECTED, 115
DEGREE RISE, KVA RATING AS INDICATED. INSTALL USING VIBRATION
ISOLATORS. STATES WITH REQUIREMENTS FOR ENERGY EFFICIENT
TRANSFORMERS PROVIDE NEMA TYPE -TP1, 150' RISE. RE -USE EXISTING
IF APPUCABLE.
4.03 PANELBOARD: NEMA PB1 AS SCHEDULED, 20" WIDE SECTION, 225 AMP
BUS (100 AMP BUS PERMITTED IF LESS THAN 30 BRANCH POLES).
PROVIDE GROUND BUS FOR IG CIRCUITS. INSTALL PER NEMA PB1.1.
PROVIDE TYPEWRITTEN BRANCH CIRCUIT DIRECTORY. LOAD CENTERS NOT
APPROVED. RE -USE EXISTING IF APPUCABLE AND STILL MEETS CODE
REQUIREMENTS. ALL COMBINATIONS OF EQUIPMENT AND MAIN /BRANCH
OVERCURRENT PROTECTION SHALL BE FULLY RATED ANC. (NEC 110.9)
4.04 CIRCUIT BREAKER: NEMA AB1 AS SCHEDULED, BOLT-ON, CENTER TRIP,
SWD IF SINGLE POLE, COMMON TRIP IF MULTI -POLE, HACR IF REQUIRED
BY LOAD. MATCH EXISTING EQUIPMENT.
4.05 FUSE: UL CLASS J. WHEN FUSING EXISTING EQUIPMENT FUSES SHALL
BE CURRENT UMITTNG AND MATCH EXISTING FUSE MANUFACTURER
PROVIDE 3 SPARE OF EACH SIZE AND TYPE INSTALLED
4.06 MAGNETIC MOTOR STARTER: NEMA ICS2, FVNR, SIZE PER MOTOR
REQUIREMENTS BUT SIZE 0 MINIMUM, NEMA 3R ENCLOSURE IF OUTDOORS.
PROVIDE CLASS 20 HEATERS PER ACTUAL MOTOR NAMEPLATE DATA.
PROVIDE 120VAC OR 24VAC FUSED CONTROL CIRCUIT AS REQUIRED.
4.07 MANUAL MOTOR STARTER: NEMA RATED, FHP, SINGLE SPEED, TOGGLE
OPERATED, MANUAL RESET OVERLOAD, NEMA 1 ENCLOSURE.
16500 - UGHTING
5.01 TENANT - FURNISHED EQUIPMENT: FOR UGHT FIXTURES AND AUXILIARY
ITEMS SCHEDULED AS FURNISHED BY TENANT, RECEIVE, PROTECT, INSTALL
CLEAN, AND LAMP UGHT FIXTURES AS SCHEDULED, OR EQUAL
5.02 CONTRACTOR - FURNISHED EQUIPMENT: FOR LIGHT FIXTURES
SCHEDULED AS FURNISHED BY CONTRACTOR, FURNISH AND INSTALL
COMPLETE, OR APPROVED EQUAL
5.03 ACCESSORIES: PROVIDE ACCESSORIES, INCIDENTAL MATERIALS AND
MOUNTING HARDWARE AS REQUIRED.
5.04 LOCATION: REFER ALSO TO ARCHITECTURAL DRAWINGS FOR FIXTURE
LOCATIONS AND MOUNTING DETAILS.
5.05 INSTALLATION: PROPERLY INSTALL AND SUPPORT ALL FIXTURES PLUMB
AND TRUE, AND FREE OF UGHT LEAKS. CONFORM TO MANUFACTURER'S
RECOMMENDATIONS AND INDUSTRY PRACTICE. LEAVE PROTECTIVE FILM
IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL LIGHT
FIXTURES IN RATED CEILINGS TO MAINTAIN THE RATING OF CEIUNG.
5.06 EMERGENCY UGHTING: PROVIDE AND LOCATE EMERGENCY UGHTING TO
MEET LOCAL REQUIREMENTS.
5.07 FLUORESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE
ELECTRONIC HPF, RAPID START, PARALLEL LAMP OPERATION, CBM, TYPE
1, CLASS P, SOUND RATED A, T-IDC20%, CCF<1.5, NAECA COMPLIANT
WHERE APPUCABLE, ENERGY SAVING BALLASTS.
5.08 RECESSED INCANDESCENT FIXTURES: IF FURNISHED BY CONTRACTOR,
PROVIDE FMC AND 150 DEGREE C FIXTURE WIRE FROM LAMP HOUSING
TO INDEPENDENT BRANCH CIRCUIT OUTLET BOX.
5.09 HID FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ANSI C82.4
COMPLIANT, HPF, ENCAPSULATED BALLASTS, ADVANCE SERIES 73B OR
EQUAL.
5.10 FINAL ADJUSTMENT: AFTER TRADE FIXTURES ARE INSTALLED BY OTHERS,
CLEAN ALL LIGHTING FIXTURES, REPLACE ALL EXPIRED LAMPS, AND
ADJUST DIRECTIONAL UGHTING AS DIRECTED BY TENANT AND ARCHITECT.
5.11 SIGN DISCONNECT: PROVIDE DISCONNECT SWITCH IN ACCESSIBLE CEIUNG
SPACE FOR STORE SIGN AND MAKE FINAL CONNECTIONS. VERIFY
LOCATION IN FIELD. SIGN FURNISHED AND INSTALLED BY OTHERS.
COORDINATE ALL REQUIREMENTS PRIOR TO BID.
16700 - SYSTEMS
7.01 DATA SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS EMT
RACEWAY SYSTEM WITH PULL WIRE FROM DATA SYSTEM EQUIPMENT
LOCATION TO ALL DATA SYSTEM OUTLETS. SIZE AS SPECIFIED ON
DRAWINGS, 3/4" MINIMUM. FOR NON- PLENUM ACCESSIBLE CEIUNG
SPACES, AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL
AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEIUNG
SPACE ARE PERMITTED IN UEU OF CONTINUOUS SYSTEM OR AS NOTED.
FOR WALL OUTLETS PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG
ADAPTER RING AND BLANK PLATE. FOR FLOOR OUTLET PROVIDE FLOOR
BOX AS ELSEWHERE SPECIFIED AND BLANK PLATE.
7.02 TELEPHONE SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS EMT
RACEWAY SYSTEM WITH PULL WIRE FROM LANDLORD STUB -IN TO
BACKBOARD, AND FROM BACKBOARD TO ALL TELEPHONE OUTLETS. SIZE
AS SPECIFIED ON DRAWINGS, 3/4" MINIMUM. FOR NON - PLENUM
ACCESSIBLE CEIUNG SPACES, .AND WHERE APPROVED BY TENANT,
LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM
OUTLET BOXES TO CEIUNG SPACE WHERE PERMITTED IN UEU OF
CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS, PROVIDE 4"
SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND TELEPHONE
PLATE. FOR FLOOR OUTLET PROVIDE FLOOR BOX AS ELSEWHERE
SPECIFIED AND TELEPHONE PLATE. PROVIDE 3/4" FIRE- TREATED
PLYWOOD BACKBOARD OF SIZE REQUIRED FOR TELEPHONE EQUIPMENT.
PROMPTLY NOTIFY TENANT WHEN ROUGH -IN INSTALLATION IS COMPLETE.
7.03 SECURITY SYSTEM ROUGH -IN: PROVIDE CONTINUOUS RACEWAY SYSTEM
WITH PULL WIRE AS INDICATED FOR INSTALLATION OF SECURITY SYSTEMS
BY OTHERS.
ELECTRICAL SYMBOL LEGEND
DRAWING
SYMBOL
BOL
DE CRIPTION
$
$ K
SWITCH - SINGLE POLE TOGGLE
SWITCH - SINGLE POLE KEY - OPERATED
SWITCH - SINGLE POLE WITH PILOT UGHT
^- $3
SWITCH - 3 WAY
9
WALL RECEPTACLE -- DUPLEX STRAIGHT BLADE
Itt
WALL RECEPTACLE - FOURPLEX STRAIGHT BLADE
15IG
RECEPTACLE - DUPLEX STRAIGHT BLADE, ISOLATED
GROUND
ifRECEPTACLE
�'
-- FOURPLEX STRAIGHT BLADE, ISOLATED
GROUND
0.0
GFI
WP
RECEPTACLE - DUPLEX STRAIGHT BLADE, GROUND
FAULT INTERRUPTER, WEATHER PROOF
1.00
7.9
SPLIT CIRCUIT RECEPTACLE
1.7
SPECIAL PURPOSE RECEPTACLE
MULTI - OUTLET ASSEMBLY (PLUGMOLD)
I • I
MISCELLANEOUS
7
Q
TELEPHONE OUTLET - WALL MOUNTED
DATA OUTLET
MOTOR - HORSEPOWER, VOLTAGE AND PHASE
AS NOTED ON DRAWINGS
D1
NON -FUSED DISCONNECT SWITCH -- SIZE AS NOTED
ON DRAWINGS
D1
NON -FUSED DISCONNECT SWITCH - SIZE AS NOTED
ON DRAWINGS
KITCHEN EQUIPMENT
FUSED DISCONNECT SWITCH - SIZE AS NOTED
ON DRAWINGS
'-
MAGNETIC MOTOR STARTER - SIZE AS NOTED
ON DRAWINGS
Q
JUNCTION BOX - WALL, CEILING
Ira
SWITCHBOARD OR PANELBOARD
TELEPHONE BACKBOARD
HVAC (REMAINING)
61
BUZZER
Q
BELL OR CHIME
PUSHBUTTON CONTROL STATION - WALL MOUNTED
T
LOW VOLTAGE CONTROL TRANSFORMER
MI
TIME SWITCH
Cl
CONTACTOR
O
THERMOSTAT (BY MECHANICAL CONTRACTOR OR
AS INDICATED)
C---...\
FINISHED - CONCEALED ABOVE CEILINGS, IN WALLS IN
FINISHED AREAS, OR EXPOSED IN UNFINISHED AREAS
�
COFINNDISUIT HED - IN OR BELOW FLOOR SLAB OR BELOW
GRADE
CONDUIT HOMERUN TO PANEL - CROSSMARKS
INDICATE NUMBER OF CONDUCTORS. NO
CROSSMARKS INDICATES 2 CONDUCTORS. DOT ON
CROSSMARKS INDICATES EQUIPMENT ISOLATED
GROUNDING CONDUCTOR.
9
20/1
FLOOR RECEPTACLE
SENSORMATIC / LOSS P.
Q
0.4
FLUSH FLOOR TELEPHONE OUTLET
0
UNDER FLOOR STUB UP
QS
SPEAKER
0 1
EXIT UGHT
41--&
EMERGENCY FIXTURE
A(.4.1
LA -1 a
TOP LETTER INDICATES UGHT FIXTURE TYPE, ( )
INDICATES NUMBER OF FIXTURES. REFER TO
UGHT FIXTURE SCHEDULE. BOTTOM LETTER AND
NUMBER INDICATES PANELBOARD DESIGNATION AND
CIRCUIT NUMBER. LOWER CASE LETTER INDICATES
SWITCH DESIGNATION.
9B -16
LETTER AND NUMBER NEXT TO ALL DEVICES AND
CONDUIT STUB -UPS INDICATES PANELBOARD
DESIGNATION AND CIRCUIT NUMBER RESPECTIVELY.
NOTES: 1. ALL IG RECEPTACLES SHALL BE ORANGE.
2. A SQUARE ENCLOSING A WIRING DEVICE SYMBOL
INDICATES A FLUSH FLOOR DEVICE.
X
NOTE:
TENANT E.C. TO SPECIFY COLORS OF ELECTRICAL
RECEPTACLES AND COVERS TO MATCH ADJACENT WALL AND
CEIUNG FINISH. COORDINATE WITH FINISH SCHEDULE OF
ARCHITECTURAL DRAWINGS PRIOR TO BID AND INSTALLATION.
20/1
1.7
NOTE;
FIRE ALARM AND SPRINKLER WORK IS TO BE PERFORMED
UNDER SEPERATE PERMIT. ENGINEERED DRAWINGS TO BE
SUBMITTED SEPERATELY.
NOTE;
ALL LOW VOLTAGE WIRING SHALL BE PLENUM RATED AND
NEATLY TIED TO STRUCTURE ABOVE. THIS WORK IS TO BE
PERFORMED UNDER SEPERATE PERMIT.
NOTE:
ALL SPEAKER WIRING SHALL BE FURNISHED AND
INSTALLED BY TENANT'S VENDOR.
1411T5 TO LINE 2
(ROLLOVER)
POINT OF DEMARCATION
(MALL TEL 'HONE CLOSET
OR STORE STOCKROOM)
TELEFOONE BLOCK
(BY LOCAL TE..EPHIOtNE PROVIDER)
LINE I
TRANS WORLD STORE PREM15E5
>LINE 2
T -I
LINE
f13YT ff)
8145 JACK
VOICE LINE5 1 AND 2
O 00
O 00
O 00
O 00
8114 TWO -LINE JACK
IN STOCKROOM
R114 THO -LINE JACK
IN STOCKROOM
10 0 0 I R.114 TWO -LINE JACK AT CASH WRAF
lo 01 000
RJ 14 TWO -LINE JACK AT
CASH WRAP OR ON SALES FLOOR
Lo 0 o I SS- INbI E 1.11E .TACK AT I5P LOCATION ONLY (P05 MODB'Q, BY TENANT
O 0 0 0
O 0 0 0
CATEGORY 5 DATA GABLE
(AT ISP LOCATION - P.0.5. MODEM)
EEEE
RJ 45 JACK
(AT GASH WRAP)
NOTE ADDITIONAL TELEPHONE LOCATIONS WITHIN STORE
MAY BE REQ)IR®. COORDINATE EXACT LOCATIONS
AND QUANTITY WITH TENANT FRO.EGT MANAGER.
NOTE: ALL CABLE SHALL BE PLENUM RATED.
3 TYPICAL TELEPHONE WIRING SETUP
\.E.2.1 NO SCALE
LA - LOAD SUMMARY
LOCATION:
STOCKROOM
CONN.
KVA
DEM
FACT.
DEM.
KVA
_
SIGN / NEON SIGN
1.2
1.25
1.5
LIGHTING
2.1
1.25
2.6
TRACK LIGHTING **
0.0
1.00
0.0
RECEPTACLES
7.9
1.00
7.9
WATER HEATER
1.7
1.00
1.7
MISCELLANEOUS
2.6
1.00
2.6
MOTORS
0.0
1.25
0.0
KITCHEN EQUIPMENT
0.0
0.65
0.0
HVAC (LARGEST)
0.0
1.25
0.0
HVAC (REMAINING)
0.0
1.00
0.0
20/1
5
X
TOTAL
15.5
20/1
16.3
CASHWRAP REC.
SPARE
0.0
20/1
** DEMAND PER NEC 410-101B AND 220 -12B TOTAL TRACK LENGTH
INSTALL ALL DEVICES ®IS" AFF BEHIND
FINISHED CABINET. E1_EGTRIGAL CONTRACTOR
TO LABEL J- BOXES.
NOTE: FOLDING SHELF CAM BE MOUNTED ON
EITHER SIDE. HOLES ARE PRE- DRILLED.
Plan Yew
NOTES:
RISER DIAGRAM BASED ON INFORMATION AVAILABLE.
ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING
EQUIPMENT BEING REUSED IS ADEQUATE AND UP TO
CURRENT CODES. ELECTRICAL CONTRACTOR TO FIELD
VERIFY ALL ELECTRICAL EQUIPMENT PRIOR TO BIDDING
JOB.
Q
MALL DISTRIBUTION
NOTE;
TENANT PANELBOARDS, DISTRIBUTION EQUIPMENT, AND OVER CURRENT
DEVICES SHALL BE DESIGNED TO SAFELY WITHSTAND THE AVAILABLE FAULT
CURRENTS, RATED IN RMS SYMMETRICAL AMPERES.
NOTE
TENANT'S ELECTRICAL CONTRACTOR TO COORDINATE AIC
RATINGS OF ALL EQUIPMENT".
LEASE LINE
17,122 AFC
15 IL J
Q
PANEL
HA
Q
T
PANEL
LA
10
TENANT
SPACE
POWER RISER DIAGRAM
NOT TO SCALE
RISER DIAGRAM NOTES
0 LANDLORD'S EXISTING 277/480 VOLT, 3PH, 4WIRE MIAN
DISTRIBUTION BOARD TO REMAIN.
Q EXISTING METER AND METER SOCKET BY LANDLORD TO REMAIN.
Q EXISTING 200A /3P CIRCUIT BREAKER BY LANDLORD TO REMAIN.
0 EXISTING 2 11C. -4#3/0 THHN -CU. & 1#6 GROUND WIRE BY
LANDLORD TO REMAIN. FIELD VERIFY EXACT STUB -IN LOCATION.
Q EXISTING 200A /3P DISCONNECT SWITCH WITH (3) 200A FUSES
BY LANDLORD TO REMAIN.
Q 2 "C -4 #3/0 THHN -CU. & 1#6 GROUND WIRE.
PANEL INFORMATION "HA". SEE PANELBOARD SCHEDULE FOR MORE
.
O 11°C-3#8 THHN -CU.
Q FLOOR MOUNTED 30 KVA TRANSFORMER.
10 1#8 BARE COPPER GROUND AND TIE TO BUILDING STEEL PER
NEC.
11 1 1/4-c -43 THHN -CU.
12 PANEL "LA ". SEE PANELBOARD SCHEDULE FOR MORE
INFORMATION.
13 TIMESWITCH (TS1). SEE SHEET El FOR SPECIFICATION.
14 CONTACTORS (C1), (C2) & (C3). SEE SHEET El FOR
SPECIFICATION.
15 AVAILABLE FAULT CURRENT PER LANDLORD PROVIDED
INFORMATION.
No.:
HA
LOCATION:
STOCKROOM
MOUNTING
SURFACE
RATED AIC:
277/480
VOLT 3 PHASE, 4 WIRE
22,000
MAIN:
LO
225 AMP
CIRCUIT DESCRIPTION
KVA
CB
No.
HL
A B C
HL
No.
CB
KVA
CIRCUIT DESCRIPTION
EXIT /EM /NL (EM/A,E)
0.4
20/1
1
*
X
1.00
2
MOTORS
5.6
1.25
SALES AREA LTG.(A)
1.6
20/1
3
0.0
X
5.9
4
50/3
5.1
30 KVA TRANSFORMER
SALES AREA LTG.(A)
1.4
20/1
5
X
TOTAL
6
20/1
4.8
CASHWRAP REC.
SPARE
0.0
20/1
7
X
8
20/1
2.5
SENSORMATIC / LOSS P.
STOCKROOM LTG.
0.4
20/1
9
X
10
20/3
1.7
VAV -1
SPARE
0.0
20/1
11
X
12
20/1
1.7
_
STORE SIGN
SPARE
0.0
20/1
13
X
14
20/1
1.7
SALES AREA REC.
SPARE
0.0
20/1
15
X
16
20/3
1.7
VAV -2
SPARE
0.0
20/1
17
X
18
20/1
2.5
SALES AREA REC.
SPACE
0.0
20/1
19
X
*
20
20/1
0.2
SPACE
SPACE
0.0
20/1
21
X
22
20/1
0.2
SPACE
SPACE
0.0
20/1
23
X
*
24
20/1
0.4
SPACE
SPACE
0.0
20/1
25
X
26
20/1
0.4
SPACE
SPACE
0.0
20/1
27
X
*
28
20/1
0.4
SPACE
SPACE
0.0
20/1
29
X
30
20/1
0.4
SPACE
SPARE
0.0
20/1
31
A T B I C
32
20/1
0.6
HVAC REC. /LTG.
CONNECTED LOAD: CALCULATED CODE DEMAND LOAD
38 AMPS MAX 3t1 KVA 10.2 10.5 10.4 34.4 KVA 41 AMPS
• HL = INDICATES HANDLE LOCK DEVICE ON CIRCUIT BREAKER(S)
(E)= EXISTING EQUIPMENT TO REMAIN
HA - LOAD SUMMARY
LOCATION:
STOCKROOM
CONN.
KVA
DEM
FACT.
DEM.
KVA
SIGN / NEON SIGN
1.2
1.25
1.5_ ..
LIGHTING
5.9
1.25
7.4
TRACK LIGHTING **
0.0
1.00
0.0
RECEPTACLES
7.9
1.00
7.9
WATER HEATER
1.7
1.00
1.7
MISCELLANEOUS
2.6
1.00
2.6
MOTORS
0.0
1.25
0.0
KITCHEN EQUIPMENT
0.0
0.65
0.0
HVAC (LARGEST)
5.9
1.25
7.4
HVAC (REMAINING) '
5.9
1.00
5.9
20/1
5
X
TOTAL
31.1
20/1
34.4
CASHWRAP REC.
SPARE
0.0
20/1
** DEMAND PER NEC 410-101B AND 220 -12B TOTAL TRACK LENGTH
No.:
LA
LOCATION:
STOCKROOM
MOUNTING
SURFACE
RATED ANC:
120/208
VOLT 3 PHASE, 4 WIRE
10,000
MAIN:
CB
100 AMP
CIRCUIT DESCRIPTION
KVA
CB
No.
HL
A B C
HL
No.
CB
KVA
CIRCUIT DESCRIPTION
S.F. DOWN LT.(D, PL)
0.3
20/1
1
X
*
2
20/1
0.4
CASH REGISTER
NEON LIGHTS (N)
0.8
20/1
3
X
4
20/1
0.4
CASH REGISTER
SALES DOWN LT. (D1)
0.4
20/1
5
X
*
6
20/1
1.0
CASHWRAP REC.
SPARE
0.0
20/1
7
X
8
20/1
0.8
SENSORMATIC / LOSS P.
SALES DOWN LT. (D1)
0.4
20/1
9
X
10
20/1
0.6
SHOW WINDOW REC.
TOILET LTG./FAN
0.2
20/1
11
X
12
20/1
1.2
_
STORE SIGN
WH -1
1.7
20/1
13
X
14
20/1
1.2
SALES AREA REC.
STOCKRM REC.
1.0
20/1
15
X
16
20/1
1.2
SALES AREA REC.
TOILET GFI REC.
0.2
20/1
17
X
18
20/1
1.0
SALES AREA REC.
SPARE
0.0
20/1
19
X
*
20
20/1
0.2
LVS STATION REC
SPARE
0.0
20/1
21
X
22
20/1
0.2
VENTED CABINET REC.
SPARE
0.0
20/1
23
X
*
24
20/1
0.4
AN RACK REC.
SPARE
0.0
20/1
25
X
26
20/1
0.4
TELEPHONE REC.
SPARE
0.0
20/1
27
X
*
28
20/1
0.4
P.O.S STATION
SPARE
0.0
20/1
29
X
30
20/1
0.4
WORK/FOLDING TABLE
SPARE
0.0
20/1
31
X
32
20/1
0.6
HVAC REC. /LTG.
SPARE
0.0
20/1
33
X
34
20/1
0.1
TIMESWITCH/ BUZZER
SPARE
0.0
20/1
35
X
36
20/1
0.0
SPARE
SPACE
37
X
38
SPACE
SPACE
39
X
40
SPACE
SPACE
41
X
42
SPACE
A I B I C
CONNECTED LOAD: CALCULATED CODE DEMAND LOAD
47 AMPS MAX 15.5 KVA 5.6 5.1 4.8 16.3 KVA 45 AMPS
* HL = INDICATES HANDLE LOCK DEVICE ON CIRCUIT BREAKER(S)
(E)= EXISTING EQUIPMENT TO REMAIN
110 VAC OUTLET IN AN
ACCESSIBLE LOCATION
ABOVE CEIUNG WITHIN
10' -0" OF CONTROL
MODULE.
CONTROL MODULE IN AN
ACCESSIBLE LOCATION
ABOVE CEIUNG.
CENTERLINE OF
ROLL-UP GRILLE
LA -8
SENSORMATIC
UNIT TYP.
$' -0"
SENSOR PLACEMENT SCHEME
TYPICAL DETAIL
-3' 1/4" =1' -O"
NOTE:
SEE FLOOR PLAN FOR
CORRECT ORIENTATION.
NOTE:
VERIFY SENSORMATIC INSTALLATION
WITH TENANT'S PROJECT MANAGER
PRIOR TO CONSTRUCTION.
SEE E -2 FOR
SPECIFIC KEYNOTES
t1.0S--2-011
CITY ut-
MAP 037008
PERMIT CENTER
Z
m
O
STORE NO: 1248
E-
C-)
DRAWN BY:
U
CO
CHECKED BY:
PROJECT COORDINATION:
SHEET NUMBER
E -3
SHEET 17 OF 17