Loading...
HomeMy WebLinkAboutPermit EL08-0215 - JORGENSEN FORGEJORGENSEN FORGE 8531 EAST MARGINAL WY S ELO8-215 City if Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 0001600023 Address: 8531 EAST MARGINAL WY S TUKW Suite No: Permit Number: EL08 -215 Issue Date: 04/11/2008 Permit Expires On: 10/08/2008 Tenant: Name: JORGENSEN FORGE Address: 8531 EASTMARGINAL WAYS , TUKWILA WA Owner: Name: JORGENSEN FORGE CORP Phone: Address: CIO DOUG JAMES , 8531 E MARGINAL WAY S Contact Person: Name: WAYNE TURK Phone: 206- 357 -1076 Address: 8531 EAST MARGINAL WAY S , TUKWILA WA Contractor: Name: D W CLOSE CO INC Address: 4304 S 131 PL , TUKWILA WA Contractor License No: DWCLOCI218O5 Phone: 206 - 242 -0058 Expiration Date: 06/30/2008 DESCRIPTION OF WORK: RUN CABLE FROM SWITCH GEAR TO BREAKER, THEN TO NEW TACCHI POWER PANEL Value of Electrical: $35,970.00 Fees Collected: $672.40 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature I hereby certify that I have read and x governing this work will be complie Date: 612 (1{'0 U Wined this permit and know the same to be true and correct. All provisions of law and ordinances h, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perform ce of am authorized to sign and obtain this electrical permit. Signature: /' C- t Date: 5t ,.•0 R- Print Name: /206/¢,c.,p U %14A-/L -77M This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -215 Printed: 05-28 -2008 Parcel No.: Address: Suite No: Citlibf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 0001600023 8531 EAST MARGINAL WY S TUKW Permit Number: Issue Date: Permit Expires On: EL08 -215 04/11/2008 10/08/2008 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: JORGENSEN FORGE 8531 EASTMARGINAL WAY S , TUKWILA WA JORGENSEN FORGE CORP C/O DOUG JAMES , 8531 E MARGINAL WAY S WAYNE TURK 8531 EAST MARGINAL WAY S , TUKVVILA WA KEITHLY ELECTRIC CO Address: 827 S DIRECTOR ST , SEATTLE WA Contractor License No: KEITHEC 101 BJ Phone: Phone: 206 - 357 -1076 Phone: 26 723 -3418 Expiration Date: 01/11/2010 DESCRIPTION OF WORK: RUN CABLE FROM SWITCH GEAR TO BREAKER, THEN TO NEW TACCHI POWER PANEL Value of Electrical: $51,262.20 Type of Fire Protection: Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting construction Signature: Print Name: ith, Fees Collected: National Electrical Code Edition: Date: $926.00 2005 0-11[1141) red this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ante of work. I am authorized to sign and obtain this electrical permit. Date: This permit shall become n and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -215 Printed: 04 -11 -2008 Parcel No.: 0001600023 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 8531 EAST MARGINAL WY S TUKW JORGENSEN FORGE Permit Number: Status: Applied Date: Issue Date: EL08 -215 ISSUED 03/04/2008 04/11/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting •f this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulaty!construption or the performance of work. Sign Print Name: ?w, Date: A if (4 doc: Cond -Elec EL08 -215 Printed: 04 -11 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httpilwww -ci. tkwila. wa. us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. • *Please Print" � A ^ King Co Assessor's Tax No_: '0016 0 - 002-3- 0C4 Site Address: S31 • , _'""` c7) W. . 0 Suite Number. N /A Floor. N /A Tenant Name: 1/4)0':-€:r.v■gUV1 r'30-. Cc,t13. New Tenant: ❑ Yes Zr..No Property Owners Name: Uc C^" gO)y- Noe -VZ, Cp. cl). Mailing Address: '531 E. U -- - i .,pc& WI . .&- 4) . -T-..,_ kk,;1Q. w A. 9 g l egg -yo I 'a City sum zip '+ .:.. "'' � W6 -�w1.; siceri ":t_i`e;?i±..64a1.:# 2°Fetdi 3aed .117 1.i: '+ r •, •• Asr e' i T° .74 : :it. ii. ;: i: t= :e . .r t; :1 „∎,4uLc> . .�,. .1..•:i.f�,- e''nr . , .i. � !+4.— ii % -k4 ' . . •••• . 02o veepnfethc e rr.A y n.c �Ir Name: WO-1..l Ip ¢Q-1r1.4.rk-- Day Telephone: (zO 6) 35'7 -1 C51‘. Mailing Address: 8 S31 E . kka...1-3‘ W1..t . `-76-1C,w t 1c.,... - Loo- s.: Q ►off Zip -y ok% City E- Mail Address: L-3flyr” 1(-. .jQrnQiRSQ- r)n ot" Q .C.cocl Fax Number:.(Z.o6) 3S1 -10`ZS Company Name: k a 1 i L I .. E I Q c�r- ►_ Ce) Mailing Address: SC) • . j ( A. 98 dg Contact Person: CU-A-+ b<3.4..t S Day Telephone: Z06 -73 6 - Cri S E -Mail Address: C.c.. -4-4"Q kQ l i-Itil. Q,(Sze UM c, • `CSC Fax Number. -Lot -74.4 - $• Contractor Registration Number: k E l rN EC, 101 bJ Expiration Date: PI / 1 I city Sam Zip Valuation of Project (contractor's bid price): S S 1 2-GZ- , �O Scope of Work (please provide detailed information):: C �-� c. 12 [ ate`.(, S ESL .mo -o Will service be altered? l ❑ Yes • / No / '` Adding more than 50 s? Yes 0 No Type of Use: ".Ince a..T- - t-1 Q. 1-aot- I -> l_-ear TL -Q... (..4Q-Q-• of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel /Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy ( Seattle City Light It Applicaitaffa .Ap iatiau Oe LIne1 4-2007. Statical Rr ®I ApplIebmox bb Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings ❑ Low voltage systems (alarm, furnace thermostat) 5140.00 $75.00 ea 555.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...... ...$75.00 (no added/altercd circuits) ❑ Service change with added/altered circuits...._ ..... ».575.00 number of added circuits ».510.00 ea ❑ Circuits added/altered without service change 550.00 (up to 5 circuits) ❑ Circuits added/altered without service change ...._550.00 (6 or more circuits) • 57.00 ea ❑ Meter /mast repair »......» 565.00 ❑ Low voltage systems 555.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation ofthe electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 558.00 ❑ Temporary service (generator)..... 575.00 ❑ MtumfacturecYmobile home service ».....» 580.00 (excluding garage or outbuilding) ❑ Carnivals_.. ......._ ............._.._._...._ S75.00 Number of concessions ............... 510.00 an Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: t.."30 ---1. -„ , Ck- ` - - ..- PRd \E T A 4/UI t N . Date: 03/03 l2O D� Print Name: We,-.4-1 rt@.. K • ■,r k Day Telephone: (Zo (-) 351 - I cfl 6 Mailing Address: 8531 E. flick.3%,rl. L ) 1 .%e. Th...•ka,,,jt 14, WA. 1%10% g0 (L( city Sum Zip Stafflnitials: `, 1 Date Application Accepted: Date Application Expires: CI FiMppseivtaninn-Apptiutiw On LinMN.mm . Electrical Puma Applieeciandac 6h Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 0001600023 Permit Number: EL08 -215 Address: 8531 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 03/04/2008 Applicant: JORGENSEN FORGE Issue Date: Receipt No.: R08 -00620 Initials: WER User ID: 1655 Payment Amount: $926.00 Payment Date: 03/04/2008 01:24 PM Balance: $0.00 Payee: JORGENSEN FORGE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 044492 926.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 926.00 Total: $926.00 71.:M r ;`3/04 7.10 i 9 S AL 6101.92 5Av doc: Receiot -06 Printed: 03 -04 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit a ov -2 t 5 PERMIT NO. le- (206)431-36 Projec t Q G ( 4$ j 4 Type of Inspection: � 4O D Address: Date Called: Special Instructions: Date Wanted: a.m •m Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. •' • COMMENTS: 0 -rt Inspector: eibuik Date: 10113/0Y El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: CURRENT TOTAL AS OF FEB 04, 2008 - To_c_ L; E141.0„-f; $52,832.84 Statement Due Date Feb 25. 2008 AMOUNT DUE THIS STATEMENT $52.832.84 Previous balances, if any, are past due. D � ONCE R�pMp AEG CpD�Fpp�'p _ ppR_1"%% 1-5y,2 6- pr-- /U . y _) ) q /7-; X62 - ?/ all 1 12008 OK TO PAY ? For information. emergencies, to report an outage or for changes to your account. please call 1 -888- 225 -577 or from out -of- state, 1-426-482. 1234. fawn paying in paraen, pleep present bath portinne. When moiling remittance. please mail to Puget Sound Energy, ROT•01H, P.O. Bos 91199. Bellevue, WA 98009 -9'189 Neese dataeh hero "and return this portion with your payment 8531 E MARGINAL WAY S, TUKWILA i II.SE 835 -947 -986 PUGET SOUND ENERGY Account B35 -944 -700 -3 Current Bill Due Date Feb 25, 2008 Yes, I want to give S to the Warm Home Fund. DRM * *CO10 IIt1u1n�mt11hint1.IuJt.III IIInJnitI, 1III111H JORGENSEN FORGE CORPORATION 0 8531 E MARGINAL WAY S TUKWILA WA 98108 -4018 Please make checks payable to Puget Sound Energy Previous balances, if any, are past due. Puget Sound Energy BOT-0114 P.O. Box 91269 Bellevue, WA 98009 -9269 0001 01 00008359447003 000002790337 000005283284 RE itiv- APR' 012u� PERMIT CEN I tt Customer JORGENSEN FORGE CORPORATION PUGET SOUND ENERGY The Energy To Go Great Things Page 2 of 6 Account No. 835 - 944700 -3 Gas Detail: 8531 E MARGINAL WAY S, TUKWILA Special Account ID: 0395 Rate 57G -1 Meter Number Pres Read P rev Read Pres Date P rev Date Turn up pressure Temp FPV __ CCF __ Code 000294005 607431 605841 01/02 01/01 1590 21.54 1.000000 3994.00 ACTL 46 1.030 4113.82 57G -I 000297285 396828 395341 01/02 01/01 1487 21.49 1.000000 3727.00 ACTL 46 1,030 3838.81 576-1 000193058 657132 655653 01/02 01/01 1479 21.53 1.000000 3714.00 ACTL 46 1.030 3825.42 57G -4 000294005 610044 607431 01/03 01/02 2813 21.04 1.000000 6539.00 ACTL 46 1.030 6735.17 57G -I 000297285 399259 396828 01/03 01/02 2431 20.95 1.000000 6062.00 ACTL 47 1.030 8243.86 57G -I 000193058 659598 657132 01103 01/02 2466 21.01 1.000000 6174.00 ACTL 46 1.030 6359.22 57G-1 000294005 613372 610044 01/04 01/03 3328 20.87 1.000000 8281.00 ACTL 47 1.030 8529.43 576-1 000297285 402331 399259 01/04 01/03 3072 20.81 1.000000 7626.00 ACTL 47 1.030 7854.78 576-I 000193058 662746 659598 01/04 01/03 3148 20.89 1.000000 7842.00 ACTL 46 1.030 8077.26 576-1 000294005 616062 613372 01/05 01/04 2690 20.98 1.000000 6701.00 ACTL 48 1.029 6895.33 57G -1 000297285 404828 402331 01/05 01/04 2497 20.92 1.000000 6206.00 ACTL 48 1.029 6385.97 57G-I 000193058 665275 662746 01/05 01/04 2529 20.98 1.000000 6293.00 ACTL 48 1.029 6475.50 57G-1 000294005 618033 616062 01 /06 01/05 1971 21.36 1.000000 4995.00 ACT L 44 1.029 5139.86 57G-1 000297285 406672 404828 01/06 01/05 1844 21.30 1.000000 4657.00 ACTL 45 1.029 4792.05 576-I 000193058 667148 665275 01/06 01/05 1873 21.34 1.000000 4751.00 ACTL 43 1,029 4888.78 576-1 000294005 620184 618033 01/07 01 /06 2151 21.18 1.000000 5427.00 ACTL 43 1.030 5589.81 576 -1 000297285 408683 406672 01/07 01/06 2011 21.13 1.000000 5058.00 ACTL 44 1.030 5209.74 570-1 000193058 669192 667148 01/07 01/06 2044 21.19 1.000000 5168.00 ACTL 42 1.030 5323.04 570-1 000294005 623102 620184 01 /08 01/07 2918 20.97 1.000000 7323.00 ACTL 44 1.030 7542.69 576-1 000297285 411391 408683 01/08 01/07 2708 20.92 1.000000 6776.00 ACTL 45 1.030 6979.28 576-1 000193058 671946 669192 01/08 01/07 2754 20.97 1.000000 6924.00 ACTL 43 1.030 7131.72 576-1 000294005 625649 623102 01/09 01/08 2547 20.99 1.000000 6390.00 ACTL 44 1.031 6588.09 576 -I 000297285 413767 411391 01/09 01/08 2376 20.91 1.000000 5940.00 ACTL 45 1.031 6124.14 576-1 000193058 674357 671946 01/09 01/08 2411 20.96 1.000000 6052.00 ACTL 43 1.031 6239.61 h 570 -! 000294005 628357 625649 01/10 01/09 2708 20.92 1.000000 6779.00 ACTL 8 44 1.031 6989.15 For information, emergencies, to report an outage or for changes to your account, please call 1- 888- 225 -5773 or from out -of- state, 1- 425 -452 -1234. Customer JORGENSEN FORGE CORPORATION PUGET SOUND ENERGY The Energy To Co Great Things Page 3 of 6 Account No, 835- 944 -700 -3 Rate 7G -I 0002972 Meter Number 85 PreS Prev Fres Read I Read I Date 418282 413167 01/10 01/09 2515 20.85 1.000000 6277.00 ACTL Prev Date Turnup Pressure FrV Pmp 1actor CCF 'Therms Code 45 1.031 6471.59 57G -1 000193058 676900 674357 01/10 01/09 2543 20.90 1.000000 6369.00 ACTL 44 1.031 6566.44 57G-1 000294005 631266 628357 01/11 01/10 2909 20.99 1.000000 7277.00 ACTL 4F 1.030 7495.31 570-1 000297285 418978 416282 01/11 01/10 2696 20.92 1.000000 6725.00 ACTL 46 1.030 6926.75 570-1 000193058 679645 676900 01/11 01/10 2745 20.97 1.000000 6859.00 ACTL 46 1.030 7064.77 570-1 000294005 633752 631286 01/12 01/11 2486 21.09 1.000000 6237.00 ACTL 46 1.030 8424.11 57G -I 000297285 421300 418978 01/12 01/11 2322 21.03 1.000000 5811.00 ACTL 46 1.030 5985.33 570-1 000193058 681998 679645 01/12 01/11 2353 21.08 1.000000 5903.00 ACTL 46 1.030 6080.09 570-1 000294005 635910 633752 01/13 01/12 2158 21.11 1.000000 5413.00 ACTL 46 1.030 5575.39 570-1 000297285 423326 421300 01/13 01/12 2026 21.04 1.000000 5070.00 ACTL 46 1.030 5222.10 576-1 000193058 684055 681998 01/13 01/12 2057 2107 1.000000 5154.00 ACTL 46 1.030 5308.62 570•1 000294005 638387 635910 01/14 01/13 2477 21.00 1.000000 6200.00 ACTL 46 1.030 6386.00 570-1 000297285 425631 423326 01/14 01/13 2305 20.95 1.000000 5756.00 ACTL 46 1.030 5928.68 570-1 000193058 686390 684055 01/14 01/13 2335 21.00 1.000000 5846.00 ACTL 45 1.030 6021.38 570-1 000294005 641250 638387 01/15 01/14 2863 20.87 1.000000 7173.00 ACTL .43 1.031 7395.36 570-1 000297285 428287 425631 01/15 01/14 2656 20.82 1.000000 6633.00 ACTL 44 1.031 8838.62 570-1 000193058 689083 886390 01/15 01/14 2693 20.87 1.000000 6757.00 ACTL 42 1.031 6968.47 570-1 000294005 644392 641250 01/16 01/15 3142 20.82 1.000000 7856.00 ACTL 43 1.030 8091.68 570 -1 000297285 431191 428287 01/16 01/15 2904 20.79 1.000000 7247.00 ACTL 44 1.030 7464.41 570-1 000193058 692050 689083 01/18 01/15 2967 20.85 1.000000 7441.00 ACTL 42 1.030 7664.23 570-1 000294005 647354 644392 01/17 01/16 2962 21.02 1.000000 7439.00 ACTL 43 1.029 7654.73 57G-1 000297285 433928 431191 01/17 01/16 2737 20.94 1.000000 6852.00 ACTL 44 1.029 7050.71 570-1 000193058 694859 692050 01/17 01/16 2809 20.94 1.000000 7046.00 ACTL 43 1.029 7250.33 570-1 000294005 651110 647354 01/18 01/17 3756 20.80 1.000000 9382.00 ACTL 44 1.029 9654.08 570-1 000297285 437375 433928 01/18 01/17 3447 20.76 1.000000 8594.00 ACTL 44 1.029 8843.23 e 570-1 000193058 698419 694859 01/18 01/17 3560 20.77 1.000000 8901.00 ACTL a 43 1.029 9159.13 For information, emergencies, to report an outage or for changes to your account, please call 1-888- 225 -5773 or from out -of- state, 1- 425 -452 -1234. Customer JORGENSEN FORGE CORPORATION PUGET SOUND ENERGY The Energy To Do Great Things Page 4 of 6 Account No. 835- 944 -700.3 Rate Meter Number Pres Read Arev Read Pres Data Prev Date Tutnup Pressure Yemp FPV mill Parlor CCF Code 57G -I 57G -I 57G-I 57G -1 000294005 000297285 000193058 000294005 656946 000297285 000193058 703929 000294005 000297285 445464 000193058 708647 000294005 663446 000297285 448788 000193058 710075 000294005 666437 000297285 451566 000193058 712918 000294005 669628 000297285 454522 000193058 715938 000294005 672498 000297285 000193058 718633 000294005 000297285 000193058 721235 000294005 000297285 653912 439976 701053 651110 01/19 01/18 437375 01/19 01/18 2601 698419 01/19 01/18 2634 853912 01/20 01/19 3034 2802 57G -I 442788 439978 01/20 01/19 2812 57G -1 701053 01/20 01/19 2876 57G -I 659833 856946 01/21 01/20 2887 57G -1 57G-I 57G -I 57G -I 57G -I 57G- I 57G -1 57G -1 57G -1 57G -1 57G -1 57G -1 442788 01/21 01/20 2676 703929 01/21 01/20 2718 659833 01/22 01/21 3813 445464 01/22 01/21 3324 706647 01/22 01/21 3428 663446 01/23 01/22 2991 448788 01/23 01/22 2778 710075 01/23 01/22 2843 666437 01/24 01/23 3191 451566 01/24 01/23 2956 712918 01/24 01/23 3020 669628 01/25 01/24 2868 573-1 457180 454522 01/25 01/24 2658 57G -1 715938 01/25 01/24 2695 57G -1 675266 672496 01/26 01/25 2770 573-1 459749 457180 01/26 01/25 57G -1 2569 718633 01/26 01/25 2602 573-1 678243 675266 01/27 01/26 2977 v 57G -1 462506 459749 01/27 01/26 2757 20.92 1.000000 7029.00 ACTL 43 1.029 7232.84 20.87 1.000000 6508.00 ACTL 44 1.029 6696.73 20.93 1.000000 6618.00 ACTL 43 1.029 6809.92 20.96 1.000000 7603.00 ACTL 44 1.030 7831.09 20.88 1.000000 7025.00 ACTL 44 1.030 7235.75 20.95 1.000000 7217.00 ACTL 43 1.030 7433.51 20.95 1.000000 7260.00 ACTL 43 1.032 7492.32 20.88 1.000000 6708.00 ACTL 43 1.032 6922.66 20.93 1.000000 6846.00 ACTL 42 1.032 7065.07 20.83 1.000000 9059.00 ACTL 42 1.033 9357 -95 20.78 1.000000 8315.00 ACTL 43 1.033 8589.40 20.88 1.000000 8635.00 ACTL 41 1.033 8919.96 21.04 1.000000 7546.00 ACTL 42 1.034 7802.58 20.96 1.000000 6984.00 ACTL 43 1.034 7221.46 21.03 1.000000 7193.00 ACTL 41 1.034 7437.56 21.06 1.000000 8049.00 ACTL 43 1.035 8330.72 20.97 1.000000 7429.00 ACTL 43 1.035 7689.02 21.05 1.000000 7632.00 ACTL 41 1.035 7899.12 21.12 1.000000 7245.00 ACTL 43 1.036 7505.82 21.06 1.000000 6697.00 ACTL 43 1.036 6938.09 21.12 1.000000 6823.00 ACTL 42 1.036 7068.63 21.11 1.000000 7006.00 ACTL 42 1.037 7265.22 21.04 1.000000 6475.00 ACTL 43 1.037 6714.58 21.09 1.000000 8595.00 ACTL 41 1.037 6839.02 21.12 1.000000 7543.00 ACTL 41 1.037 7822.09 21.05 1.000000 6959.00 ACTL 42 1.037 7216.48 For information, emergencies, to report an outage or for changes to your account, please call 1-888- 225 -5773 or from out -of- state, 1-425-452-1234. Customer JORGENSEN FORGE CORPORATION PUGET SOUND ENERGY The. ;-n,,; _ �;: • Do vrr,7r Things Page 5 of 6 Account No. 835 -944 -700 -3 Rate Meter Number Pres Read Prev Read Pres Date Prev Date Turnup Pressure Temp FPV - f3YI/1actor CCF Therms Code 57G -I 57G-I 57G -I 57G -I 57G -I 57G -I 57G -I 57G -I 57G-I 57G -I 57G -1 57G -1 57G -I 57G -I 57G -I 57G -1 000193058 000294005 000297285 000193058 000294005 000297285 000193058 000294005 000297285 000193058 000294005 000297285 000193058 000294005 000297285 000193058 /24049 681548 405565 727185 684687 468470 730149 687605 471180 732915 690285 473671 735445 692802 478021 737827 721235 01/27 01/26 678243 01/28 01/27 462506 01/28 01/27 724049 01/28 01/27 681548 01/29 01/28 465565 01129 01/28 727185 01129 01/28 684687 01/30 01/29 468470 01/30 01/29 730149 01/30 C1/29 687605 01131 01/30 471180 01/31 01/30 732915 01/31 01/30 690285 02/01 01/31 473671 02/01 01/31 735445 02/01 01/31 2814 21.09 1.000000 7138.00 ACTL 40 1.037 7402.11 3305 21.05 1.000000 8339.00 ACTL 42 1.034 8622.53 3059 21.02 1.000000 7702.00 ACTL 43 1.034 7963.87 3136 21.10 1.000000 7941.00 ACTL 41 1.034 8210.99 3139 21.07 1.000000 7940.00 ACTL 41 1.032 8194.08 2905 20.98 1.000000 7316.00 ACTL 42 1.032 7550.11 2964 21.05 1.000000 7504.00 ACTL 41 1.032 7744.13 2918 21.01 1.000000 7369.00 ACTL 41 1.033 7612.18 2710 20.96 1.000000 6822.00 ACTL 42 1.033 7047.13 2766 21.00 1.000000 6991.00 ACTL 41 1.033 7221.70 2680 20.99 1.000000 6750.00 ACTL 42 1.034 697950 2491 20.90 1.000000 6252.00 ACTL 43 1.034 6464.57 2530 20.97 1.000000 6372.00 ACTL 42 1.034 8588.65 2517 21.02 1.000000 6353.00 ACTL 42 1.033 6562.65 2350 20.93 1.000000 5907.00 ACTL 2382 42 1.033 6101.93 20.99 1.000000 6012.00 ACTL 41 1.033 6210.40 Dates Charge Description 1 Quantity I Price per Unit Amount 01/02/08 02/01/08 Customer Charge 01/02/08 02/01/08 Transportation Firm Contract Delivery Demand 3.500 Therms 081.02 Per Therm 01/02/08 02/01/08 Excess Volume Not Balanced 01/02/08 02/01/08 Greater Than 10 ° Overrun Charge 01/02/08 02/01/08 Unauthorized Usage Charge 01/02/08 02/01/08 Transportation Service Commodity Charge 01/02/08 02/01/08 Transportation Service Commodity Charge 01/02/08 02/01/08 Transportation Service Commodity Charge 01/02/08 02/01/08 Transportation Service Commodity Charge 01/02/08 02/01/08 Transportation Service Commodity Charge 01/02/08 02/01/08 Transportation Service Commodity Charge 01/02/08 02/01/08 Tukwila City Tax Current Gas Charges A late fee of 1% will apply to overdue charges, if any. Please see the reverse side for details on late payment charges. A 3.852% state utility tax is included in gas rates charged. 25.000 Therms (a) 8.12788 Per Therm 25,000 Therms (a $.07863 Per Therm 50,000 Therms (4) 8.05127 Per Therm 100,000 Therms a 8.0341 Per Therm 300.000 Therms (p) 8.02549 Per Therm 147,176.12 Therms a 8.02042 Per Therm 826.158.59 (gZ 8.0667 Per Dollar 8800.00 83,570.00 8.00 5.00 S.00 83.197.00 81.965.75 82.563.50 83,410.00 57,647.00 83,005.34 81,744.78 527,903.37 For information, emergencies, to report an outage or for changes to your account. please call 1-888- 225 -5773 or from out -of- state, 1- 425 -452 -1234. Customer JORGENSEN FORGE CORPORATION PUGET SOUND ENERGY The Energl ro Dc Great Things Page 6 of 6 A 75000 v 20000 T 15000 R M 10000 P r D 0 A Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Jan Feb 2007 Months 2008 Tm-nnnrMI 1Iuu11II11111 Account No. 835-944-700-3 ENERGY USAGE COMPARISON For BIII Period This Year Last Year Change Jan -Feb No, of days 31 31 0 THRM use 547176,1 618119.1 29057 Avg, THRM use per day 20876,6 19939.3 937.3 Avg. temp. per day 37F 38F -1F For information, emergencies, to report an outage or for changes to your account, please call 1- 888 - 225 -5773 or from out -of- state, 1- 425 - 452 -1234. AVG. LOAD @ 800A 4160/480V 3000K V A XFMR 480Y/277V 3000A BREAKER PANEL 400A 3 480V PLANNER 1 400A 3 480V 0 PANEL B ) fL ) 2 • CODE COMPLIANCE NFPA 7 APR - `7 2008 City Of Tukwila B . ILD NG D ION 600A 3 0 480V 3 MAGNAFLUX C —rL) 800A 480V 30 5 AIR COMP C� —) BLANK fL 6 1200A 480V 30 TRENCH BUS DUCT ) 70A 3 70A 30 480V 480V TOOL ROOM WELDER OUTLET 7 ) 200A 3 0 480V SPARE I 200A 30 480V 200A 30 480V 13 NEW OFFICES —�— ) 9 ( 111 400A 30 480V PANEL A 200A 30 480V CAP BANK st. ) 4 8 10 12 BLANK ` 14 c� /l El -. ice\ FILE C Permit No. pear review approval is subject to errors and otnISSIons. approval of construction documents does not authorize the violation of any adcpted cock) or offfmance. Receipt of and oonations is adolowledged: City of TUkwIIa BUILDING DIVISION \--- REVISIONS No changes shall be made to COrP of work without prior approval ot Tukwila Building Division. Revisions will require a new plan may include additional plan NOTE R review fees. t and Public Works, Building Division PERMIT NUMBER SEPARATE PERMIT REQUIRED FOR: Mechanical KPlumbing 0Electrical lg Gas Piping City of Tukwila BUILDING DIVISION EL082J& FILE COPY RECEIVED APR `012008 PERMIT CENTER PROJECT MANAGER: CURT DAVIS CONTACTS 206- 818 -4112 DRAWN BYE BCM DA 7 E, 03 -11 -08 CHECKED BY CMD DATE. 03 -11 -08 APPROVED BY DATE, APPROVED BY, DATE SUBTITLE, JFI PAGE DIVIS POWER MONITOR 1 OF 2 IONi IDRAWING FILE NAME DRAWING NUMBER REV TITLE. SIZE, B SCALE. NONE LATE Keithly Electric Company XFMR P946 26420/4160V 7500 KVA 4160V MAIN ACB1 F2 DISCO5 1 -9 F2 DISC 1 400A XFMR 1 3000 T PRESS F2 DISC 2 400A XFMR 11 MAINT. OFF/ MELT LAB F2 DISC 3 400A XFMR 7 + 8 1000T/675T PRS BLT GRNOR/ BLT TURNER F2 DISC 4 400A XFMR 3,4,5 MS /SHPNG /HT230VDC F2 DISC 5 400A SPARE F2 DISC 6 800A MACH SHP /MN ❑FFC PLT LTG /AIR C❑MPSRS TO 4160/480V XFMR F2 DISC 7 400A ALUM HT FRGFRNCS ENGINERING F2 DISC 8 800A BG HSE /2000T TPRS FRG /MLT RCTFR F2 DISC 9 800A XFMR 6 RINGMILL /EXPANGER UPSETTER /BLT YD FRGFRNCS ENGINERING REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 7 2008 City Of Tukwila ILDYNG D ION PROJECT MANAGER CURT DAVIS CONTACT' 206- 818 -4112 DRAWN BY. BCM DATE. 03-12-08 CHECKED BY CMD APPROVED BY DAIE. 03 -11 -08 :AIE APPROVED BY DATE SUBTITLE. DIVISION. SCALE. NONE DATE JFI POWER MONITOR PAGE 2 OF 2 DRAWING FILE NAME JF1 072 DRAWING NUMBER REV Keithly Electric Comfy SIZE, 13 TITLE JORGENSEN FORGE 8531 E MARGINAL WAY S. Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 29, 2008 Wayne Turk Jorgensen Forge Corporation 8531 East Marginal Wy S Tukwila WA 98108 RE: Request for Extension Building Permit No. D08 -119 Electrical Permit No. X8-215 Jorgensen Forge Corp — 8531 East Marginal Wy S Dear Mr. Turk, This letter is in response to your written request for an extension to Permit Numbers D08 -119 and EL08 -336. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. The City of Tukwila Building Division will be not be extending D08 -119 since an inspection has been conducted and automatically extended your permit expiration date to March 21, 2009. However, EL08 -215 will be extended an additional 180 days from the date of expiration, through April 6, 2009, per your request. If you should have any questions, please contact our office at (206) 431 -3670. Sincerely, ifer Marshall e�lnit Technician File: Permit No. D08 -119 & EL08 -215 P:\Permit CenterExtension Letters \Permits\2008\EL 08 -215 Permit Extension.doc Page 1 of 1 jem / ?nn Cnrrthrpntpr Rnulpt/ard- Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 • JORGENSEN FORGE CORPORATION ALUMINUM — TITANIUM — SPECIALTY STEELS 8531 EAST MARGINAL WAY SOUTH SEATTLE, WASHINGTON 98108 PHONE (206) 762 -1100 FAX (206) 763 -0848 Ms. Jennifer Marshall Permit Technician City of Tukwila Department of Community Development Dear Ms. Jennifer Marshall 1,11112/1 Jorge requesting a extension on our Electrical per per t Jorgensen has been awaiting for the final field from TI ' o heinland, this report comes out of Italy. Just toda scheduling for TUV to do their final inspection on October 07, able to schedule the final needed permit inspections from th If there is anything else I need to do please let me know. - o• #D08 -11 Sincerely, Wayne Turk wturk(jorgensenforge.com (206) 357 -1076 Direct (206) 255 -8177 Cell (206) 357 -1075 Fax 10[0$16 t # EL 08 -215 nd Foundation the Tacchi machine we received confirmation and 008 from this inspection I will then be City of Tukwila. a1646#41 16°611 446 �r -u-o8 RECEIVED SEp 2 2 2008 DEVELOPMENT -Re P i01040 09 -08 -2008 Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director WAYNE TURK 8531 EAST MARGINAL WAY S TUKWILA WA 98108 RE: Permit No. EL08 -215 8531 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 -431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writinM and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/08/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, xc: er Marshall it Technician Permit File No. EL08 -215 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 •�s- <<°� ci- ®s April 21, 2008 Jorgensen Forge Corporation 8531 East Marginal Way South Seattle Washington 98108 -4018 Attn: Stan Durham, Brian Kralovec, Wayne Turk, Jim Birch Re: 400 Amp Feeder to the Tachi Machine RE cY71� ne; F��,rc.� APR 2 41008 NEF1114!! CEAITEh DW Close Company is pleased to present our proposal for the above referenced project. We have prepared our proposal with the information provided per our walk through on Wednesday March 5t n, 2008. Conduits installed overhead above the production area are figured to be installed on off hours but not on overtime. The installation of the 400 Amp breaker is quoted to be installed on a normal Saturday overtime rate. This quote reflects our understanding of the project and includes all material, labor and permit fees to complete the project under the following scope. Electrical Scope: Tachi Machine Feeder $ 35,970.00 1. Provide and install (1) 400 amp 480V 30 Feeder originating from the electrical distribution panel at column line DN7 and terminating at a location at column line AE16 towards the north. Given the industrial surroundings the wiring method used will be rigid steel conduit with 500mcm copper conductors only. 2. Provide and install a 400 amp 480V 30 fused disconnect w/ fuses for lockout and a disconnecting means for the new Tachi machine. 3. The 400 amp 480V 30 power connection to the Tachi control panel is included provided it is within an 8' radius from column AE16. 4. Test and confirm the presence of nominal 480V power at the Tachi line connections. Assumptions: 1. Ample recording and /or load calculation has been done to prove that the distribution panel at column DN7 has the capacity for the new Tachi Machine. 2. The wire pull between the Main Distribution Panel and the new 400 Amp Disconnect can be pulled during normal business hours. Project Exclusions: 1. Washington State Sales Tax 2. UL Listing 3. Cutting or Patching 4. Hidden conditions 5. Any electrical relocation of equipment 6. Utility Charges or Fees 7. Overtime ELECTRICAL DESIGN, CONSTRUCTION AND SERVICE WA ELECTRICAL LICENSE / DWCLOCI21805 • WA CONTRACTORS LICENSE / DWCLOC *21305 4304 South 131st Place • Seattle, WA 98168 • Main Phone: (206) 242 -0058 • Fox: (206) 242-2299 www.dwdose.com • 24 -HOUR SERVICE • • The scope of work represents our understanding of the project. This quote will be subject to review and subsequent revisions after 30 days. Should you have any questions or require further information, please contact us at your convenience. Respectfully, Rolando (Ferddi) Martin DW Close Company Cell: (206) 793 -4957 Tel: (206) 242 -7225 Fax: (206) 242 -2787 Email: rolandomPdwclose.com Acceptance of Proposal: The prices and conditions above are satisfactory for the work described. You are hereby authorized to perform the work as outlined above. Payment will be made within 30days or as agreed to otherwise. Owner is to provide fire and all other necessary insurance's. Alterations from the above specifications may involve additional costs and will be executed only upon written notice. All agreements contingent upon strikes, accidents or delays beyond our control Owner /Contractor: Date: ELECTRICAL DESIGN, CONSTRUCTION AND SERVICE WA ELECTRICAL LICENSE # DWCL0C121805 • WA CONTRACTORS LICENSE I DWCLOC *11305 4304 South 131st Place • Seattle, WA 98168 • Main Phone: (206) 242 -0058 • Fax: (206) 242 -2299 www.dwclose.com • 24-HOUR SERVICE PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -215 DATE: 04 -01 -08 PROJECT NAME: JORGENSON FORGE SITE ADDRESS: 8531 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: (., B �I:�ing Dies on Public Works n Fire Prevention Structural Planning Division Permit Coordinator El It DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -03 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg El Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 05-01 -08 Approved Approved with Conditions I Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: hup : / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: c'- ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # t after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan ChecWPermit Number: FL Ug_`2-IS Project Name: ' t APR 24 2008 PERMIT CENTS, Project Address: 2'531 E/.-sT Ul;C, w`t Contact Person: W AYNe.= R . i u k Phone Number:(2 1/43C) 3c> - 107 C Summary of Revision: li.“.P„pa -- p r e - Von,AKwKA G(;' W114(7- G -t- nut VID.V( ID pp G � Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: r_SX Entered in Permits Plus on INIA \applicationslforms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electricia or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License DWCLOCI21805 Licensee Name D W CLOSE CO INC Licensee Type ELECTRICAL CONTRACTOR UBI 600326448 Ind. Ins. Account Id Business Type CORPORATION Address 1 4304 S 131ST PL Address 2 City SEATTLE County KING State WA Zip 98168 Phone 2062420058 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/25/1979 Expiration Date 6/30/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License THOMERE930DB Electrical Administrator Information License THOMERE930DB Name THOME, ROBERT E Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date DETHLEFS SPARWASSER PLLC AGENT 01/01/1980 MORELAN, BRUCE D, CHIEF EXECUTIVE IR OFFICER 10/25/2007 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= DWCLOCI21805 04/24/2008 Look Up a Contractor, Elect an or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. License Information License KEITHEC101BJ Licensee Name KEITHLY ELECTRIC CO Licensee Type ELECTRICAL CONTRACTOR UBI 601218771 Ind. Ins. Account Id Business Type CORPORATION Address 1 827 S DIRECTOR ST Address 2 City SEATTLE County KING State WA Zip 98108 Phone 2067233418 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/11/1990 Expiration Date 1/11/2010 Suspend Date Separation Date Parent Company Previous License KEITHEC339R9 Next License Associated License KEITHDM963DZ Master Electrician Information License KEITHDM963DZ Name KEITHLY, DANIEL M Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date KEITHLY, DANIEL 01/01/1980 KEITHLY, ROBERT 01/01/1980 Bond Information 1 Page 1 of 2 https: // fortress. wa. gov /Ini/bbip /printer.aspx ?License= KEITHEC 101 BJ 04/11/2008