HomeMy WebLinkAboutPermit EL08-0228 - WESTFIELD SOUTHCENTER MALL - H & MH&M 867 SOUTHCENTER MALL ELO8-228 Cityilif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 867 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -228 Issue Date: 04/11/2008 Permit Expires On: 10/08/2008 Tenant: Name: H & M Address: 867 SOUTHCENTERMALL , TUKWII,A WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARCIA PEDDICORD Phone: Address: 633 SOUTHCENTER MALL TRAILER #3 , TUKWILA WA Contractor: Name: SEA TAC ELECTRIC INC Address: 7056 S 220TH ST , KENT WA Contractor License No: SEATAEI077RW Phone: Expiration Date: 12/16/2009 DESCRIPTION OF WORK: ELECTRICAL SYSTEM FOR TI OF NEW MALL SPACE Value of Electrical: 300,000.00 Fees Collected: $4,658.75 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: D_l( II 10' I hereby certify that I have read and ex ua ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied wi hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or t - • erf`• ce of rk. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: �� //// O This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -228 Printed: 04 -11 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 867 SOUTHCENTER MALL TUKW Suite No: Tenant: H & M PERMIT CONDITIONS Permit Number: EL08 -228 Status: ISSUED Applied Date: 03/10/2008 Issue Date: 04/11/2008 1: * * *FI.FCTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: 9// ' / S doc: Cond -Elec EL08 -228 Printed: 04 -11 -2008 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. -0 Project No. PO 12I 7 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION King Co Assessor's Tax No.: 636y.to - 00/0 Site Address: 869 SCV#HEAMei /1Q LL- Suite Number: /930 Floor: / Fr 2- Tenant Name: HE H Property Owners Name: SO'4 WCehVE& /%Qtt[ New Tenant: "( Yes ❑ ..No Mailing Address: 200 $CU cen;mit 12O(i- 7[,ttcvitA city I State 98/ Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: /7L1QUA AtaY eo /13" ":"? 2 Mailing Address: 643 Stutken,e a *al j .3 Day Telephone: 2e"- 902- GO % //S/O -8/'3Y98 SS We evA 9g /B8 City State Zip E -Mail Address: /»o1Pa6(iGbrd�QleS A1•ebM AV All 74 '4 Fax Number: 206- 2%- 3 /s, -Rd r / /// ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 300, 000 Scope of Work (please provide detailed information): %ENaNf /tjF2OUEt/e f- eica /'V A NEB ehaosge, //ACt.. Oo4,ci VOnr • 1.E1./61- / = Si 991/ SOP- &lee- 2 : /$, S/8 Spf'f Will service be altered? X Yes ❑ No Adding more than 50 amps? J Yes ❑ No Type of Use: ,74/0/L NAV* Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: Puget Sound Energy ❑ Seattle City Light H.Wpplications\Forms- Applications On Lne\4 -2007 - Electrical Permit Application.dot bh ❑ Remodel X Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits .$10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65,00 ❑ Low voltage systems ....................... $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: 440_ S. CoAei Mailing Address: 2j9O r%de,vee S11710•gE Loop IDate Application Accepted: 3� a C Date: 6SAM78 Day Telephone: VC' 81'/- 3v 89 hane.04 C4 'WO / City stale Zip Date Application Expires: (a t 0-0 O H `Applwauonfforms- Applications On Line 4 -2007 - Electrical Permit Application doc bh Staff Initials: 1 Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -228 Address: 867 SOUTHCENTER MALL TUKW Status: ISSUED Suite No: Applied Date: 03/10/2008 Applicant: H & M Issue Date: 04/11/2008 Receipt No.: R08 -01523 Initials: WER User ID: 1165 Payment Amount: $58.00 Payment Date: 05/07/2008 03:58 PM Balance: $0.00 Payee: SEA -TAC ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8804 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 2157 05/08 9711 TOTAL 58.00 doc: Receiot -06 Printed: 05-07 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci. tukwila. wa. us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -228 Address: 867 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/10/2008 Applicant: H & M Issue Date: Receipt No.: R08 -01149 Initials: User ID: Payee: JEM 1165 Payment Amount: $3,727.00 Payment Date: 04/11/2008 01:24 PM Balance: $0.00 SEA -TAC ELECTRIC, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8790 3,727.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 3,727.00 Total: $3,727.00 doc: Receiot -06 Printed: 04 -11 -2008 • City of Tukwila • Nt Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -228 Address: 867 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/10/2008 Applicant: H & M Issue Date: Receipt No.: R08 -00677 Initials: WER User ID: 1655 Payment Amount: $931.75 Payment Date: 03/10/2008 12:31 PM Balance: $3,727.00 Payee: MBH ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 55492 931.75 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 931.75 Total: $931.75 =16Y, .?'... 10 7710 TO'':k 33151.38 '4") doc: Receiot -06 Printed: 03 -10 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 f,Log- 2.13 ti Project: 41.4.4A Type of Inspection: 1100 Address:1101. N k e , Date Called: Special Instructions: Date Wanted: (/ / �� .. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 .4_ Inspector: .S1 &IWO, Date: o 6 LI $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fbe must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: CLoY -z1� INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION II" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4- 11 11 Type of Inspection: 2t ^0 Address: 0 Date Called: �„.. Special Instructions: Date Wanted: ^ J l IC ( Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Am6iK g ef-re� -Rf /VP' I1)04Tlfi T¢,ikki5rotlrlf�t.6.� O.K. 'ro STOCK'StA-Fr Inspector: ky\Weit...\ 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 01 1 514 Receipt No.: 'Date: eke4e946 ate, _ — Aft&seCtlingekaillitireftiaeliaibrim.Arbagfilvd. , \f) INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit aDg- ?.,2.'8 PERMIT NO. ITn (206)431 -3670 Project: H 4._ 0 Type of Inspection: 7100 Address: �-1 ti / Date Called: Special Instructions: Date Wanted: 1 ( ' a.m. 'Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Date: 01 it lag EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: fir- ��-�- INSPECTION NO. INSPECTION RECORD Retain a copy with permit -M7 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION b2-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti Project: 4- el Type of Inspection: 70 03 Address: y{p I e , _ Date Called: Special Instructions: j(T'�(',�"~', Date Wanted: VI I &n. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: As No Inspector: 6T/A/04,t ❑ $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 01 /II /Di d � Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: 14 Type of Inspection: Address: vsn tiI./ Date Called: Special Instructions: Date Wanted: itc.)p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. CO MENTS: V1 Inspector: 13NAI El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ,Date: 07 it cs Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit ei.og- 22-47 PERMIT NO. Project: 111 Type of Inspection: 1003 Address: vo Him/ Date Called: Special Instructions: Date Wanted: / r p.. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1K. C61L1PJN L.J6e., QO V ! Ai Inspector: oAltic‘ ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: of I i o(c Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. ti Project: Type of Inspection: 700, Address: vai 4W IP l Date Called: Special Instructions: Date Wanted: 1 /1 4m. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: .1;1 &-rtivetz, Date: El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: �..m taY m taaRelmarftw .1.1.4i .:aw.3..A.KAarae INSPECTION NO. INSPECTION RECORD Retain a copy with permit GL PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 44 4 Type of Inspection: �0Q� Address: N476.7 .1 Date Called: Special Instructions: Date Wanted: /Q7 p.m. Requester: (( Phone No: 5`15 Cot -°q.-5 n kot cxf I ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: .- C o)d7 ) rAi -it A4Fotyt 5 CeAi crooz, 440 14 Di,4 gibs et..5 rot. Pir-faryir IDc_M 5`15 Cot -°q.-5 n kot cxf I . Inspector: Date: $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 b Project: IA 4. Type of Inspection: 7oo3 Address: vo Date Called: Special Instructio s: Date Wanted: 07 (/ 4rn Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: O.K. oAirrs (t 2 44 rrfl#/4t �oo AQe-4 Inspector: Date: ° of (ay. n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: �. J- �.A�rL•s t. - _sew Y_. _ - _ _ W �iw1ti, �a INSPECTION RECORD Retain a copy with permit INSPECTION NO PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 0 Projec / ,11 Type of Inspection: 1 1 A`Jddrr ss: Cl fJ4 /1/ Date Called: special Instructions: Date Wanted: Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: , j /) 4.- 5-7/' i f/2 )N T ft / 'l Ola ,- /$$'/1/46. ' -IJP1 fi/W Z.5 Inspec /L L JY744,404fai Date:. /2... ./6 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: Ar INSPECTION NO. ' INSPECTION RECORD Retain a copy with permit fMi- 48 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Proje cf.. fryi Type of Inspection: 70---7 r s A , 5c.. Aiaz1..... Date Called: Special Instructions: Date Wanted: rj 6 /!� Vn. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. / COMMENTS: itligel 0/4 -- c s,L/ t -.16r r3 -- i) /i i t/t TA'/ 3 014.— 6-rege firms. - ''fFi�Y Inspector �j ` f Date:z /f r/o, $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 14 4 isi Type of Inspection: 7003 Address: c c 1 KW" ' Date Called: Special Instructions: Date Wanted: PIO m. Requester: Phone No: EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: fil,ftkt, 442 /Fttg\ Inspector: ffti Date: 06 Jup t $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. (Receipt No.: Date: ■, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 1 1 Type of Inspection: �oo Address: I 0141 Date Called: Special Instructions: Date Wanted: Gil, m ( per;, Requester: Phone No: DApproved per applicable codes. El Corrections required prior to approval. COMMENTS: tiOku4:11-K,N(At-i Inspector: &A/6C Date: n top e:h3 n $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ��b4e� .�— - •.A %Jo-. 'i�..Le. –tea taiL.f�la...�aes.' ..': �iar:.��,.m�.u.i mil! /-2 INSPECTION NO. INSPECTION RECORD Retain a copy with permit v PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tz 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 7 PI Type of Inspection: X063 Ares : <i/�a/ �/r 41 Date Called: Special Instructions: Date Wanted: 6/9, Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: ii) /61., so/Z c,L/L,//45.- co1/41 — / �- F4-00A Inspe /i G j Date: ‘/ (//° El $58.00 REINSPECTION FEE REWIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd.. 'Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: � it- Type of Inspection: Addrpcs:� 1 1 ,, 41, Date Called: Special Instructions: Date Wanted: (eat Ca Ti Requester: Phone No: Approved per applicable codes. COMMENTS: M tEltr-ections required prior to approval. c 'sf- A fO/Z /966F AmnoJ( ,1/1)A 7iv?az C.i9A/ifiPG5 Inspector: ) 4 4 l` 7 4./wc Date: 4/6 /o P ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 1i tP Type of Inspection: aSy: 0/ c AL, Date Called: Special Instructions: Date Wanted: /-;" a.m p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ('Z` J /�/ rA4 3 Insp r: Date: eh-A El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: N /0 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Project: , /HI Type of Inspection:_ 0 3 VV y 2/ - Frvi"' I &/ ' L - 'Q m ;,C � ` Date Called: Special Instructions: Date Wanted: S7Requester: ? a. Phone No: `proved per applicable codes. El Corrections required prior to approval. COMMENTS: pi C` ( —. c-e l4Ijetl4 — MI-4 2- K e -em y 2/ - Frvi"' I &/ ' L - 'Q m ;,C ID $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPE(� ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION > ". 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ` f /H, �'�`l Type of Inspection: �- A <I0 s Add ess: /� L7 seem ,uv 44 Date Called: ,Date Instructions: Date Wanted: 11 a im. Requester: Phone No: proved per applicable codes. ['Corrections required prior to approval. COMMENTS: ph Inspe 5(,,,/4.i1116 // Date//C p' $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit \c, PERMIT NO. (206)431 -3670 "'I Project: ! , 4- in Type of Inspection: - L /L //1)& - A i2 A / Address. ��''ff 47A f ‹5t, �/f /A Date Called: OA:- /.oll& - / /C4/'i ..9 cavva r' II 'A)C /&'v,/ 5 Special Instructions: Date Wanted: a/ %6 a.m Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. c OMMENTS: pg - L /L //1)& - A i2 A / - A L- . f 4Ci( 4,, //a/S -fie c,7- -0/4- (T )LU,,, K -- ,rf OA:- /.oll& - / /C4/'i ..9 cavva r' II 'A)C /&'v,/ 5 Inspecto . Date c A ! _ ` $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 tto -; 2c` Project:, / �� Type of Inspection: 7�3 AreD Ib ,Q Called: + Special Instructions: Date Wanted: ,c7 4.7 - a Requester: Phone No: \() Approved per applicable codes. Corrections required prior to approval. • COMMENTS: r1/21- ,,,. L.fo , — :.•,,: ;! Ls 4/ i / I S -e%T" l /(/'\ Inspecto Date: 1 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: j 0 Type of Inspection: -7 Address: yo F(7 / 727641414/* filik Date Called: (101.111&— t=-I- fif c.5 Special Instructions: Date Wanted: ,.-•"" Al- a. Requester: Phone No: pproved per applicable codes. D Corrections required prior to approval. COMMENTS: p/q. .1Z -- N ALL (101.111&— t=-I- fif c.5 Inspe (D/4 i ` /4ij6 r Date: C, Alo'f, 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 61,401-nV CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project: 4- t Type of Inspection: Date Called: 700�- Address:? 114,14i Special Instructions: Date Wanted: p� S V r P•m. Requester: Phone No: DIApproved per applicable codes. EJ Corrections required prior to approval. COMMENTS: P�- O.K. - c Q ucic c,Jaic,S 10% F 5T Inspector: Sn 6NAck, Date: LJ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: iaaam— .z INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit laOcr-2-7-CC PERMIT NO. (206)431 -3670 Project: ���� Type of Inspection: 7003 Awl Date Called: Special Instructions: Date Wanted: �/� G Requester: Phone No: proved per applicable codes. Corrections required prior to approval. OMMENTS: f,9. 0/4-- -tc,-.7---/eifi/ cc.,AA14 Inspector4 AirafinaCP Date: 1th 9/or 0558.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: l a INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION f- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: let; Type of Inspection: ,3 Address: `� � Date Called Special Instructions: Date Wanted: / �" Requester: Phone No: proved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: pA a/& iji11- s— 5 /L77& J 3 — X. )4CiAT . S:e C -OANf4 V(C-J 7 I GrtJS f, 2, .7 4.eCcie r Ins pect Date: ,i/C/"/ /71/ Z04// El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD f — `„ Retain a copy with permit h- ") PERMIT NO. CITY OF TUKWILA BUILDING DIVISION I'--' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr ' t�� Type of Inspection: 70-00 Date Called: Specia Instructions: Date Wanted: ,� L� /� a.m. P.m. Requester: Phone No: proved per applicable codes. 0 Corrections required prior to approval. 014-- SICTION - cl "m /rna5 FiloArr 7= /Lit $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 46f-7•4( PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 114"4 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ii, 4 �„ !%itf Type of Inspection: - ro: Date Called: Special Instructions: Tate Wanted: a n Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. 0/ OMMENTS: (j9 �.� Roo Inspect 1 &G kif4/Mh/611 Date: /a. /! ir 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: 'Date: THORSON BAKER & Associates, Inc. H &M South Center US159 Tukwila, WA TBA/jn — 2008 -0049 Addendum No. B — LL Coments /Arch Clarification Permit #EL08 -228 Issued March 19th, 2008 Page 1 Consulting Engineers 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com (330) 659 -6688 phone (330) 659 -6675 fox tba @thorsonbaker.com email REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAY - 22008/ City Of Tukwila B I DIN DIVISION This Addendum No. B becomes as fully a part of the first issued documents as if originally issued therewith or originally contained therein. This Addendum embraces additions to, deductions from, all changes and substitutions in, or clarifications and emphasis on part of requirements of the drawings and specifications, pertaining to ALL TRADES herewith mentioned for the completion of the PROJECT. DRAWING NO. E0.2 • Revised panelboard note 8 ( "10 ") per landlord comments. • Added (5) circuits for audio power. • Revised circuit for F.A.C.P. and one back door I.G. circuit to allow audio circuits to utilize one phase of the panel. DRAWING NO. E0.3 • Revised main feeder, meter and means of disconnect per landlord comments. Added fused disconnect switch provided by landlord in tenant space. DRAWING NO. E0.4 • Revised F.A.C.P. circuit number. • Revised F.A.C.P. specifications of the control panel to indicate each floor shall be zoned separately. DRAWING NO. E2.2b • Added emergency lighting in rooms with no windows per landlord comments. REVISION Niel F claonacal • Electrical • Civil • Landscape Architecture Y1200812008- 00491Documents1CorrespondenceOutgoing1Addendums- Bulletins12008 -0049 ADOOB(elecafCidi dD • CINCINNATI, �Q + COPY RECEIVED APR 16 2008 PERMIT CENTEFI Structural • THORSON BAKER & Associates, Inc. Addendum No. B Permit #EL08 -228 Issued March 19th, 2008 Page 2 DRAWING NO. E3.1 • Revised sensormatic to call out floor type. DRAWING NO. E3.2a Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 phone Richfield, Ohio 44286 (330) 659 -6675 fax www.thorsonbaker.com tba @thorsonbaker.com email • Revised sensormatic to call out floor type. • Revised coded notes to show correct number. • Added holiday cashwraps per H &M comments. • Revised cashwrap details. • Added wireless access points per H &M comments. DRAWING NO. E3.2b • Revised Temp. Control Relay circuit number. • Relocated timeclock per H &M comments. • Removed j -box for security cameras. DRAWING NO. E3.3 • Added speakers and conduit. DRAWING NO. E3.4a • Added speakers and conduit. DRAWING NO. E3.4b • Added speakers and conduit. DRAWING NO. E3.5 • Added camera locations and revised coded note "2 ". Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI THORSON BAKER & Associates, Inc. Addendum No. B Permit #EL08 -228 Issued March 19th, 2008 Page 3 Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 phone Richfield, Ohio 44286 (330) 659 -6675 fax www.thorsonbaker.com tba @thorsonbaker.com emoll DRAWING NO. E3.6a • Added camera locations and revised coded note "2 ". DRAWING NO. E3.6b • Added camera locations and revised coded note "2 ". • Added j -box for security cameras. DRAWING NO. E3.8b • Revised F.A.C.P. circuit number and F.A.C.P. location. DRAWING NO. E4.1 • Added security power and data to Admin Room. • Revised data quantity in Admin Room per H &M Comments. • Revised rack power per H &M Comments. • Added /Revised Audio power. • Revised coded note "6" per landlord comments. DRAWING NO. E5.1 • Revised specifications 16050 & 16120 per landlord comments. DRAWING NO. E5.3 • Revised data conduit fill capacity per H &M comments. • Revised audio specifications to call out correct vendor. End of Addendum Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI 2006 Washington State Nonresidential Energy Code Compliance Form Project u`a J -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address HEN _ sus, Date 4/14/2008 5S1::,7 632. Southeaster Parkway For Building Department Use Tukwila, WA 9g-1 2-1 Applicant Name: Jeffery D. Miterko, P.E. Applicant Address: 3030 West Streetsboro Rd., Richfield, OH 44286 Applicant Phone: 330 - 659 -6688 EXPIRES SEP 0 3 2009 REVIEWED FOR CODE COMPLIANCE NFPA 7 MAY - 2008 Oty Of Tukwila B IIDIN DM ION REVISION NLIL F9LE COPY ELOS 219 gECEIVED APR 16 2008 PERMIT CENTER 2006 Washington State Nonresidential Energy Code Compliance Form nten or'tLici tin. rs na,.: t 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address H&M - se. Date 4/14/2008 c,? 6+33 - Southcenter Parkway For Building Department Use Tukwila, WA o U ft/ Applicant Name: Jeffery D. Miterko,[[P.E. Applicant Address: 3030 West Streetsboro Rd., Richfield, OH 44286 Applicant Phone: 330 - 659 -6688 Project Description Office Areas J New Building ❑ Addition ❑ Alteration II Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor/room no.) Occupancy Description Allowed Watts per ft2'• Area in ft2 Allowed x Area Retail Sales Merchantile Retail SalesArea 1.50 20913.0 31369.5 Office Areas Administrative, Manager, Deco Room 1.00 425.0 425.0 Storage Areas Storage Area 0.50 2037.0 1018.5 Common Areas Reatrooms, Corridors, Stairwells, Electric, Janitor Roc 0.80 1144.0 915.2 Retail Display Merchandise Display Luminaire Areas 1.50 18228.0 27342.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 61070.2 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Retail Sales A - 35W Metal Halide Downlight 226 46.0 10396.0 Retail Salsa, Retail Display B2 - (2) lamp 35W Metal Halide Adjustable 32 92.0 2944.0 Retail Sales C - 42W Compact Fluorescent Downlight 59 44.0 2596.0 Retail Sales D - 70W Metal Halide Downlight 4 79.0 316.0 Retail Sales D2 - 150W Metal Halide Downlight 5 170.0 850.0 Retail Sales El - 35W Metal Halide Downlight 26 45.0 1170.0 Common, Storage Areas G - (2) lamp 32W Fluorescent Chain -Hung 1 64.0 64.0 Common, Storage Areas H - (3) lamp 32W Fluorescent Lay -in 27 96.0 2592.0 Retail Sales L4 - F28WT5 4' Fluorescent Strip 86 32.0 2752.0 Retail Sales L3 - F21WT5 3' Fluorescent Strip 4 28.0 112.0 Retail Sales L2 - F14WT5 2' Fluorescent Strip 24 20.0 480.0 Retail Sales P - 35W Metal Halide Pendant 57 48.0 2736.0 Retail Sales P1 - 70W Metal Halide Pendant 2 79.0 158.0 Retail Sales, Retail Display T - 35W Metal Halide Track with Current Limiters (15W /f 1868 15.0 28020.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 55186.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form nterior- Lighting Summary; (back 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use LPA` (W /sf) 0.9 Use' Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) LPA` (W /sf) 1.0 Automotive facility Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments', restaurants/bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces'' 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation Warehouses.", storage areas Workshops Parking garages 1.0 0.5 1.4 0.2 Hotel /motel 1.0 Hotel banquet/conference /exhibition hall" 2.0 1.8 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form L1ighting;r Motor !and.r T ransformer 2006 Washington State Nonresidential Energy Code Compliance Forms Permit P1ansI,Ch "eckli 'LTG -CHK Revised July 2007 Project Address 'Date H &M - Space #1430 l 4/14/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations no vertical glazing Indicate vertical glazing on plans no overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w /backup Indicate location no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 1Max. watts 'Indicate watts for each exit sign 1 l I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture . a . 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) yes I 1540 (Transformers 'Indicate size and efficiency If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energ Code Compliance Form Lightin ransformer .ermi' laps, ec -CH'S 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function Independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Hai _ s "o__ Date 3/17/2008 $(71 Southcenter P- "2y Out (( For Building Department Use Tukwila, WA 94:gc ca Applicant Name: Jeffery D. Miterko, P.E. Applicant Address: 3030 West Streetsboro Rd. , Richfield, OH 44286 Applicant Phone: 330 -659 -6688 CODE E RE COMPLIANCE APP F' OVED MAR `' 7(I06 City OI Tukwila ILDIN ' D . I : N FILE COPY 'EXPIRES I'3-O'1 RECEE. ED CITY OF TUKWILA MAR 19 2008 PERMIT CENTER CORRECTION LTR# Interio mm r in 2006 Washington State Nonresidential Energy Code Compliance Form u Revised July 2007 Project Info Project Address H�.f _ e� Date 3/17/2008 sycq 6.2, Southcenter nart.wsy ntek (1 For Building Department Use Tukwila, WA _1 0 irg I Applicant Name: Jeffery D. Miterko, P.E. Applicant Address: 3030 West Streetsboro Rd., Richfield, OH 44286 Applicant Phone: 330 - 659 -6688 Project Description Office Areas ❑ Plans Included requirements. - New Building ❑ Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive (i Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area Retail Sales Merchantile Retail SalesArea 1.50 20913.0 31369.5 Office Areas Administrative, Manager, Deco Room 1.00 425.0 425.0 Storage Areas Storage Area 0.50 2037.0 1018.5 Common Areas Restrooms, Corridors, Stairwells, Electric, Janitor Roc 0.80 1144.0 915.2 Retail Display Merchandise Display Luminaire Areas 1.50 18228.0 27342.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 61070.2 Lihtin Wattage g g Location Number of Watts/ Watts (floor /room no.) Fixture Description Fixtures Fixture Proposed Retail Sales A - 35W Metal Halide Downlight 226 46.0 10396.0 Retail Sales, B2 - (2) lamp 35W Metal Halide Adjustable 32 92.0 2944.0 Retail Display Retail Sales C - 42W Compact Fluorescent Downlight 59 44.0 2596.0 Retail Sales D - 70W Metal Halide Downlight 4 79.0 316.0 Retail Sales D2 - 150W Metal Halide Downlight 5 170.0 850.0 Retail Sales El - 35W Metal Halide Downlight 26 45.0 1170.0 Common, Storage G - (2) lamp 32W Fluorescent Chain -Hung 1 64.0 64.0 Areas Common, Storage H - (3) lamp 32W Fluorescent Lay -in 27 96.0 2592.0 Areas Retail Sales 14 - F28WT5 4' Fluorescent Strip 86 32.0 2752.0 Retail Sales L3 - F21WT5 3' Fluorescent Strip 4 28.0 112.0 Retail Sales L2 - F14WT5 2' Fluorescent Strip 24 20.0 480.0 Retail Sales P - 35W Metal Halide Pendant 57 48.0 2736.0 Retail Sales P1 - 70W Metal Halide Pendant 2 79.0 158.0 Retail Sales, T - 35W Metal Halide Track with Current Limiters (15W /f 1868 15.0 28020.0 Retail Display Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 55186.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. • 2006 Washington State Nonresidential Energy Code Compliance Form Interior L`ightir'g�urrmmary;'(ba Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Forms Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. 1 „6116L .., -. .,.... .■.w......0 ..,..,,. r.••....... Use' -- , -- - -, LPA` (W /sf) Use LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) Penitentiary and other Group 1 -3 Occupancies 1.0 1.0 Convention center 1.2 Courthouse 1.2 Police and fire stations° 1.0 Cafeterias, fast food establishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail7), retail banking, mall concourses, wholesale stores (pallet rack shelving) School buildings (Group E Occupancy only), school classrooms, day care centers 1.5 1.2 Exercise center 1.0 Gymnasia5, assembly spaces5 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses' l, storage areas 0.5 Hotel banquet/conference /exhibition hall" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries 1.3 Plans Submitted for Common Areas Only` Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and fighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen. fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power "Allowance 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address H sM - Spews-614,3o cp 1 a, z 4 / Date Revised July 2007 3/17/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor/room no.) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception"' Adjusted LPA Watts per ft2 ** From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Com•Iiance Form •Z :.. .: t Ark t yt• .. 11fi • 1 Lighten Motor, an�i7ransformer P_erm�ttP 1 - tL < 5 ans :Checklis 4,4.4 CH Revised Juty 2007 2006 Washington State Nonresidential Energy Code Compliance Forms Project Address / R&M - sse S��] ,t- OW )) Date 3/11/2008 �'N'cea -4 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations yes 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations no vertical glazing Indicate vertical glazing on plans no overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w/backup Indicate location no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location no 1513.6.1 (a) occup. sensors Schedule with type and locations no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability): Indicate size of zone on plans yes 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1514 Max. watts Indicate watts for each exit sign LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n. a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 Elec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) yes I 1540 (Transformers Indicate size and efficiency If "no" is circled for any question, provide explanation: • Consulting Engineers • THORSON BAKER & Associates, Inc. H &M South Center US159 Tukwila, WA TBAfjn — 2008 -0049 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com Addendum No. B — LL Coments /Arch Clarification Issued March 19th, 2008 Page 1 (330) 659 -6688 phone (330) 659 -6675 fax tba @thorsonbaker.com email This Addendum No. B becomes as fully a part of the first issued documents as if originally issued therewith or originally contained therein. This Addendum embraces additions to, deductions from, all changes and substitutions in, or clarifications and emphasis on part of requirements of the drawings and specifications, pertaining to ALL TRADES herewith mentioned for the completion of the PROJECT. DRAWING NO. E0.2 • Revised panelboard note 8 ( "10 ") per landlord comments. • Added (5) circuits for audio power. • Revised circuit for F.A.C.P. and one back door I.G. circuit to allow audio circuits to utilize one phase of the panel. DRAWING NO. E0.3 • Revised main feeder, meter and means of disconnect per landlord comments. Added fused disconnect switch provided by landlord in tenant space. DRAWING NO. E0.4 • Revised F.A.C.P. circuit number. • Revised F.A.C.P. specifications of the control panel to indicate each floor shall be zoned separately. DRAWING NO. E2.2b • Added emergency lighting in rooms with no windows per landlord comments. Structural • Mechanical • Electrical • Civil • Landscape Architecture Y: 1200912008- 00491pocumentsteanespondenceoutganglAddendums- Bugetins1200 8-0049,,AD008(adOgigftLI) • CINCINNATI THORSON BAKER & Associates, Inc. Addendum No. B Issued March 19th, 2008 Page 2 DRAWING NO. E3.1 • Revised sensormatic to call out floor type. DRAWING NO. E3.2a Consulting Engineers 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com • Revised sensormatic to call out floor type. • Revised coded notes to show correct number. • Added holiday cashwraps per H &M comments. • Revised cashwrap details. • Added wireless access points per H &M comments. DRAWING NO. E3.2b • Revised Temp. Control Relay circuit number. • Relocated timeclock per H &M comments. • Removed j -box for security cameras. DRAWING NO. E3.3 • Added speakers and conduit. DRAWING NO. E3.4a • Added speakers and conduit. DRAWING NO. E3.4b • Added speakers and conduit. DRAWING NO. E3.5 • Added camera locations and revised coded note "2 ". (330) 659 -6688 phone (330) 659 -6675 fax tba @thorsonbaker.com email Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI }'Rt 111 1111 THORSON BAKER & Associates, Inc. Addendum No. B Issued March 19th, 2008 Page 3 Consulting Engineers • 3030 West Streetsboro Road (330) 659 -6688 phone Richfield, Ohio 44286 (330) 659 -6675 fax www.thorsonbaker.com tba @thorsonbaker.com email DRAWING NO. E3.6a • Added camera locations and revised coded note "2 ". DRAWING NO. E3.6b • Added camera locations and revised coded note "2 ". • Added j -box for security cameras. DRAWING NO. E3.8b • Revised F.A.C.P. circuit number and F.A.C.P. location. DRAWING NO. E4.1 • Added security power and data to Admin Room. • Revised data quantity in Admin Room per H &M Comments. • Revised rack power per H &M Comments. • Added /Revised Audio power. • Revised coded note "6" per landlord comments. DRAWING NO. E5.1 • Revised specifications 16050 & 16120 per landlord comments. DRAWING NO. E5.3 • Revised data conduit fill capacity per H &M comments. • Revised audio specifications to call out correct vendor. DRAWING 0. M2.1 • Added ge • See co notes 9 and 10 1 for balancing damper information. Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI THORSON BAKER & Associates, Inc. Addendum No. B Issued March 19th, 2008 Pam: 4 DRAWI G NO. M2.2a • As ,ed general notes 9 and 10. • See oded note 1 for balancing damper in • mation. • Remo -d fire dampers. Consulting Engineers • 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com DRAWING NO. M . b • Added genera otes 9 and • Removed fire da ' sers. DRAWING NO. M2.3 • Load calculatio are att. hed. DRAWING NO. M • Plumb ' s calculations are attac ' ed. • Ad • d general note 5,6, and 7. DRA G NO. M4.1 Modified Specification 15300 — Fire Prot tion Systems. End of Addendum (330) 659 -6688 phone (330) 659 -6675 fax tba @thorsonbaker.com email Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI • Consulting Engineers • THORSON BAKER & Associates, Inc. H &M South Center US159 Tukwila, WA TBAIjn — 2008 -0049 Addendum No. A— Electrical Comments Issued March 18th, 2008 Page 1 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com (330) 659 -6688 phone (330) 659 -6675 fax tba @thorsonbaker.com email This Addendum No. A becomes as fully a part of the first issued documents as if originally issued therewith or originally contained therein. This Addendum embraces additions to, deductions from, all changes and substitutions in, or clarifications and emphasis on part of requirements of the drawings and specifications, pertaining to ALL TRADES herewith mentioned for the completion of the PROJECT. DRAWING NO. E0.1 • Added fixture type "EM3" to the lighting fixture schedule. • Removed fixture type "EM" from the lighting fixture schedule. DRAWING NO. E0.2 • Revised transformer `T -1" from 112.5KVA to 150KVA. • Added AIC ratings to all panels. • Added EWC for first floor and added additional holiday cashwrap. DRAWING NO. E0.3 • Revised transformer "T -1" from 112.5KVA to 150KVA. • Added AIC ratings to all tenant panels and transformers. • Revised main feeder per what landlord is supplying. • Added transformer restraint detail. DRAWING NO. E2.1 • Removed fixture type "EM" and replaced with fixture type "EM3" to provide 1 foot candle average along path of egress. Structural • Mechanical • Electrical • Civil • Landscape Architecture Y120081 2008- 00491pauments1Correspondence OutgoinglAddendums- Bulle6nst2008-0049_ADOOA(ad Qi iKELD • CINCINNATI • Consulting Engineers • THORSON BAKER & Associates, Inc. Addendum No. A Issued March 18th, 2008 Page 2 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com DRAWING NO. E2.2a • Added emergency "C" fixture to landlord alcove behind tenant space. DRAWING NO. E2.2b • Added emergency "C" fixtures to landlord alcoves behind tenant space. • Revised location of one "H" fixture in stock room. DRAWING NO. E3.1 • Revised cashwrap detail. • Added EWC to first floor. DRAWING NO. E4.2 • Added new EWC to Powerlink schedule. • Removed seismic details from this sheet and modified sheet name. DRAWING NO. E4.3 • New sheet for seismic details and bracing for electrical equipment. • Modified seismic notes to reflect Washington building code. End of Addendum (330) 659 -6688 phone (330) 659 -6675 fax tba @thorsonbaker.com email Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI • Consulting Engineers • THORSON BAKER & Associates, Inc. H &M South Center US159 Tukwila, WA TBArn — 2008 -0049 Plan Review #1 (EL08.228) Plan Check Engineer: Bill Buterbaugh Date: March 12th, 2008 Page: 1 3030 West Streetsboro Road (330) 659 -6688 phone Richfield, Ohio 44286 (330) 659 -6675 fax www.thorsonbaker.com tba @thorsonbaker.com email The following are responses to the comments presented to TBA on the above referenced review. Plan Review #1 • Thorson Baker & Assoc., Inc. Response o Revised seismic notes to call out Washington State. Plan Review #2 • Thorson Baker & Assoc., Inc. Response o Replaced transformer "T-1" with a 150KVA transformer. Plan Review #3 • Thorson Baker & Assoc., Inc. Response o Provided fault current calculations and AIC ratings for all panels and disconnect switches on sheets E0.2 & E0.3. Plan Review #4 • Thorson Baker & Assoc., Inc. Response o Provided seismic design and engineering for stacked and suspended transformers on new sheet E4.3. Plan Review #5 • Thorson Baker & Assoc., Inc. Response o Fixture schedule located on sheet E0.1. Structural • Mechanical • Electrical • Civil • Landscape Architecture vvon2oostootoccunentscayespone.c. adogaeaene .n,.emmwuooemisaaoo+cc a,.laa RICHFIELD • CINCINNATI • Consulting Engineers • THORSON BAKER & Associates, Inc. Plan Review #1 (EL08.228) Plan Check Engineer: Bill Buterbaugh Date: March 12th, 2008 Page: 2 3030 West Streetsboro Road Richfield, Ohio 44286 www.thorsonbaker.com (330) 659 -6688 phone (330) 659 -6675 fax tba @thorsonbaker.com enroll Plan Review #6 • Thorson Baker & Assoc., Inc. Response o Revised emergency lighting on first floor to provide sufficient illumination (average of 1 foot candle) along path of egress. Emergency lighting on first floor sales has an average of 1.8 foot candles along path of egress. Emergency lighting on second floor sales has an average of 1.2 foot candles along path of egress. Emergency lighting on second floor b -o -h has an average of 3.9 foot candles along path of egress. o Verified photometrics with Visual Lighting Program. o Egress lighting was added to alcoves behind tenant space. There is existing landlord emergency lighting in the mall concourse and corridors. Y 1200812C080049ZcammMlCmeapvi0sce OWOoin9Ndladim+- &lletw{ 2008- 0049_PR001(Plan Rerier Rsspuise(.doc Structural • Mechanical • Electrical • Civil • Landscape Architecture RICHFIELD • CINCINNATI I March 13, 2008 • City of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Marcia Peddicord 633 Southcenter Mall, Trailer #3 Tukwila, WA 98188 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL08 -228 H & M — 867 Southcenter Mall Dear Mr. Peddicord, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Bill Buterbaugh, at 206 973 -4758, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenirer service. If you have any questions, please contact me at (206) 433 -7165. �u- Brenda Holt Permit Coordinator encl xc: File No. EL08 -228 P:\Permit Center \Correction Letters \2008\EL08 -228 Correction Ltr #I.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Building Division Review Memo Date: March 12, 2008 Project Name: H & M Permit #: EL08 -228 Plan Reviewer: Bill Buterbaugh 1. California standards are not recognized by Washington State. 2005 NEC and 2006 IBC with Washington State amendments. 2. Transformer T1 is rated at 112.5 KVA. Connected lighting Toad of 142.5 KVA exceeds the transformer rating. 3. Provide fault current calculations for transformers and AIC ratings for equipment. 4. Provide seismic design and engineering for stacked and suspended transformers. Design per 2006 IBC requirements for seismic zone D -2. 5. Provide fixture schedules 6. Provide an average one foot - candle illumination at the floor along the entire egress pathway and exit discharge per 2006 IBC Section 1006. oP ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -228 DATE: 04 -16 -08 PROJECT NAME: H & M SITE ADDRESS: 867 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTM (E�N� S :� „ Bing id 'vision Public Works r Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04-17 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved f Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -15 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 •PERMITCOORDCOpY• PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL08 -228 DATE: 03 -19 -08 PROJECT NAME: H & M SITE ADDRESS: 867 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: B iI. ing Divis on Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 03-20-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: / Approved ❑ Approved with Conditions In Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DUE DATE: 04 -17 -08 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -228 DATE: 03 -11 -08 PROJECT NAME: H & M SITE ADDRESS: 867 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS_ : BtJlfding 4 Public Works C Fire Prevention Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: -vi Incomplete DUE DATE: 03 -13 -08 Not Applicable u Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ DUE DATE: 04 -10 -08 Not Approved (attach comments) lg Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only �y' CORRECTION LETTER MAILED: ✓ ' O v Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: lh21 Documents/routing sllp.doc 2 -28-02 PROJECT NAME: 4- M PERMIT NO: LO 8—;.01-8 SITE ADDRESS: Soo+Leevi RAN ORIGINAL ISSUE DATE: 4 -1( og REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS ISSUED DATE STAFF INITIALS 1 14-16-08 Summary of Revision: WO- 5 -7_013' 1mq Summar of Revision: w., �t4 pk. C t elfvo,i on , See_ cSo ea ,et-1.f mar,roi,4tic. s010 „(4ivti( Received by: i%vih }44,, iv REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF I INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, et. Date: Plan Check/Permit Number: 2-Lo ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # ®' Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: i-1- JU1, Project Address: Sto 1 So LA-Mt, h4.4 Contact Person: Jc_ p . P1;4 e4 k 'per. Phone Number: 3 _ (,E — C. C.?? Summary of Revision: I P1 ea S-- ee. G ' f -t Q I e /t1 e-r k trr4t, v(_ Y kid 1e iddc i Le N�� /Ai); I r e YC�P.rtl' P_,i C CXQ�� �v r I271S Lt Lcc,,�) (a.-4 cer>?, rn��� • I Re v i SJ 06, LvA cn e-r 'C C'f I; .42,11P r7 — rh L ► G/✓1 RECEIVED APR 16 2000 ki4MIT CENTEF. Sheet Number(s): E O. L i 2.0, 31 ao.+ 2.L. 't-b� � 3. I1 E 3.241 - . Z , X 3.3 E3.44 i_3. 416.) � 3.S) "Cloud" or highlight all areas of revision including date of revision 3, 3. 3.Sta 4t 25,( S, - Received at the City of Tukwila Permit Center by: Entered in Permits Plus on L'�' ( (' 0 Iapplcationslfonms- applications on line\revision submittal Created: 8-13 -2004 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 13•3//q /a? Plan Check/Permit Number: L Dek ❑ Response to Incomplete Letter # Ey Response to Correction Letter # / ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: l 191 Project Address: 5/6 7 S /j / Tk kki) t✓-1 , 14 /WV/ / Contact Person: t�' ►`tik r� �1 e /a) n Phone Number: 3: - 4..97 - G 4.?? Summary of Revision: See_. /ei"e /lar -r t r'e re : e / are !e.l'e -i nitrrA t r'eic rel ets24 .,,1 A- L Sheet Number(s): 2... D . I .6.2� 10.3 le A/ i L t - /1 f 2.2 X 2.26, .E .1 { 3 2,1. t 3. �. 3.�� � 3. "Cloud" or highlight all areas of revision including date of revise 3.5 3 .4,./t. 3 fah 3. / 1 2t 4t.�t . S t S. Received at the City of Tukwila Permit Center by: tt°S) Entered in Permits Plus on VA Lel. Leh 1applicationslforms- applications on line\revision submittal Created: 8-13 -2004 Look Up a Contractor, Electron or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SEATAEI077RW Licensee Name SEA TAC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601510212 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 7056 S 220TH ST Address 2 City KENT County KING State WA Zip 98032 Phone 2538725553 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 12/16/1993 Expiration Date 12/16/2009 Suspend Date Separation Date Parent Company Previous License SEATAEC131QC Next License Associated License HARGRT *974CD Master Electrician Information License HARGRT *974CD Name HARGREAVES, TOM Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HARGREAVES, TOM AGENT 12/17/1993 HARGREAVES, TOM PRESIDENT 12/17/1993 HARGREAVES, • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SEATAEI077RW 04/11/2008 Time: 2:13 pm co 0 0 a a 0 ID 0 0 0 0 0 E 0 3 0 Platted Tuesday March 18, 2008 2:13pm by ataylor ELECTRICAL ABBREVIA11ONS A AC AFF AFG AMU AIC ARCH. ATS AWG BKR BLDG. CAN CCTV CH CONTR CT CU CUH DE DN DS DWG. (E) or EXIST. EB EC. EF EH ELEC. EM EMT EQ. BR EUH EWC EWH FA FACP FC FLUOR FPB F.P.C. FS FT. G.C. GF1 GND HID HOA HP HPS HVAC IG INCAND. JB KCMIL K.EC. KVA KW LTG LV MAN MAU MAX MCB MCC M.C. MECH. MFR MH MIN MLO MOD MSB MTD NEC NF NFPA NIC NL NTS OCC 0 or P PB - P.C. PNL PRE PVC RE RR RTU SPKR SPST TS TTB TV TYP. UH UL UON W W WP X'FMR AMPS AIR CONDITIONING UNIT ABOVE FINISH FLOOR ABOVE FINISH GRADE AIR HANDLING UNIT ASYMMETRICAL INTERRUPTING CURRENT ARCHITECTURAL AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAGE BREAKER BUILDING CONDUIT CABLE TELEVISION CLOSED CIRCUIT TELEVISION CHILLER CONTRACTOR COOLING TOWER COPPER CABINET UNIT HEATER DUAL ELEMENT DOWN DISCONNECT SWITCH DRAWING EXISTING ELECTRIC BASEBOARD ELECTRICAL CONTRACTOR EXHAUST FAN ELECTRIC HEATER ELECTRICAL EMERGENCY ELECTRICAL METAWC TUBING EQUAL EXISTING TO REMAIN ELECTRIC UNIT HEATER ELECTRIC WATER COOLER ELECTRIC WATER HEATER FUSE FIRE ALARM FIRE ALARM CONTROL PANEL FAN COIL UNIT FLUORESCENT FAN POWER BOX (VAV) FIRE PROTECTION CONTRACTOR FLOW SWITCH FOOT /FEET GENERAL CONTRACTOR GROUND FAULT INTERRUPTING PROTECTION GROUND HIGH INTENSITY DISCHARGE HAND - OFF - AUTOMATIC HORSEPOWER HIGH PRESSURE SODIUM HEATING, VENTILATION, AIR CONDITIONING ISOLATED GROUND INCANDESCENT JUNCTION BOX ONE THOUSAND CIRCULAR MILS KITCHEN EQUIPMENT CONTRACTOR KILOVOLT AMPERE KILOWATT LIGHTING LOW VOLTAGE MASTER ANTENNA TV MAKE -UP AIR UNIT MAXIMUM MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER MECHANICAL CONTRACTOR MECHANICAL MANUFACTURER METAL HALIDE MINIMUM MAIN LUGS ONLY MOTOR OPERATED DAMPER MAIN SWITCHBOARD MOUNTED NATIONAL ELECTRIC CODE NON FUSED NATIONAL FIRE PROTECTION ASSOCIATION NOT IN CONTRACT NIGHTLIGHT NOT TO SCALE OCCUPANCY PHASE PULL BOX PLUMBING CONTRACTOR PANEL POWER ROOF EXHAUSTER POLYVINYL CHLORIDE REMOVE EXISTING REMOVE AND RELOCATE ROOF TOP UNIT SPEAKER SINGLE POLE SINGLE THROW TAMPER SWITCH TELEPHONE TERMINAL BOARD TELEVISION TYPICAL GAS FIRED UNIT HEATER UNDERWRITER'S LABORATORY UNLESS OTHERWISE NOTED UNIT VENTILATOR VOLTS WATTS WEATHERPROOF TYPE DEVICE (NEMA 3R RATED) TRANSFORMER ELECTRICAL SYMBOL LEGEND SYMBOL DESCRIPTION -41- MANUFACTURER CATALOG NUMBER CONDUIT WITH WIRING RUN CONCEALED IN OR ABOVE CEILING OR WALL, OR RUN EXPOSED IN UNFINISHED AREAS. CROSS HATCHING INDICATES NUMBER OF CONDUCTORS (112 A.W.G. - MINIMUM). PROVIDE A CODE -SIZED GROUND WIRE IN ALL CONDUITS IN ADDITION TO THE CONDUCTORS SHOWN. • - INDICATES ADDITIONAL ISOLATED GROUND WIRE. CONDUIT WITH WIRING RUN CONCEALED BELOW FLOOR. CROSS HATCHING INDICATES NUMBER OF CONDUCTORS (112 A.W.G. - MINUMUM). PROVIDE A CODE -SIZED GROUND WIRE IN ALL CONDUITS IN ADDITION TO THE CONDUCTORS SHOWN. CUT AND PATCH FLOOR AS REQUIRED. - -' APPROXIMATE FIXTURE COUNT LIGHTING PANEL.BOARD MOUNTED 6' -6' TO TOP. SEE PANEL SCHEDULES TYPE AND ELECTRICAL ONE --LINE DIAGRAM. ❑J SAFETY SWITCH - TYPE AND RATING AS SHOWN ON PLANS A SECURITY SYSTEM CONTACT 6MHT639E4N /AHTC6ISCLPF ITEM 1:91108ES ACCESSORIES: 0- 64363, 1951 20A - 120V/277V SINGLE POLE TOGGLE SWITCH MOUNTED 48' AFF, UNLESS $ NOTED OTHERWISE WHRE INDICATED - SUBSCRIPT "3' DENOTES 3 WAY SWITCH B2 AND SUBSCRIPT "M DENOTES MANUAL MOTOR STARTER) 2 20A- 2P- 3W -125V GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED 18" A.F.F., U.O.N. SPECIALTY LIGHTING 20A- 2P- 3W -125V GROUNDING TYPE DOUBLE DUPLEX RECEPTACLE MOUNTED 2-LAMP 39W METAL HALIDE ADJUSTABLE ACCENT FIXTURE WITH ELECTRONIC BALLAST. 277VAC NOTE 1 18" A.F.F. U.O.N. 32 20A- 2P- 3W -125V ISOLATED GROUND TYPE DUPLEX RECEPTACLE MOUNTED TIC 18" A.F.F. U.O.N. PLT42 /30/4P /ALTO 20A- 2P- 3W -125V ISOLATED GROUND TYPE DOUBLE DUPLEX RECEPTACLE MOUNTED 6VF142TE4-- EM /6VFSCL ITEM t:US1400ES ACCESSORIES: 0- 20888, 1951 18" A.F.F. U.O.N. US1400ES 20A- 2P- 3W -125V GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLE MOUNTED 48" A.F.F., UNLESS NOTED OTHERWISE. D 20A-- 2P- 3W -125V SPLIT (2- CIRCUIT) GROUNDING TYPE DUPLEX RECEPTACLE 1 MOUNTED AT 18' A.F.F., UNLESS NOTED OTHERWISE. ONE CIRCUIT SHALL FEED SPECIALTY LIGHTING TOP HALF AND ONE CIRCUIT SHALL FEED BOTTOM HALF OF RECEPTACLE. Qr JUNCTION BOX - SIZE AS REQUIRED BY N.EC. ® INDICATES CODED NOTE ra DOORBELL PUSH BUTTON MID. 4.8' A.F.F. S DOORBEIJ_ MID. 84" A.F.F. $N MANUAL MOTOR STARTER WITH SIZED OVERLOAD PROTECTION. ii LIGHTING CONTROL TIME CLOCK $K LIGHTING CONTROL OVERRIDE KEY SWITCH 0 SPEAKER, FLUSH MOUNTED U.O.N. P 4MHT439E4 /AHTC4WDSCLPF ITEM 1:91106 ACCESSORIES: 0- 64882, 1951 4.5" RECESSED 35W METAL HALIDE DOWNLIGHT WITH SEMI - DIFFUSE ALUMINUM HAMMERTONE SUNRISE OPTIC REFLECTOR, CLEAR GLASS LENS, AND WHITE TRIM RING. 277VAC. NOTE 1 91106 "P" G ADJACENT TO SYMBOL INDICATES PENDANT MOUNTED '7 COMMUNICATIONS OUTLET MOUNTED 18' AT A.F.F. U.Q.N. 5(D) PROVIDE CONDUIT SIZED PER SPECIFICATION'S FILL REQUIREMENTS 4' -0' LONG CHAIN MOUNTED FLUORESCENT FIXTURE. WITH ELECTRONIC BALLAST. NOTE 3 (3/4' MINIMUM) TO DATA RACK IN LAN ROOM WITH CABLING PER VERIFY ON LIGHTING PLANS SPECIFICATIONS. Nr ADJACENT TO SYMBOL INDICATES WALL MOUNTED AT 96 54' A.F.F. REFER TO RESPONSIBILITY SCHEDULE SECTION 16740 F32T8 /830 /ALTO DAY -BRITS LEIItiH(S) ADJACENT TO SYMBOL DEFINES THE USE OF THE OUTLET: 2'x4' RECESSED FLUORESECNT FIXTURE WITH WITH .125' ARCYLIC PRISMATIC LENS, FLAT STEEL DOOR AND ELECTRONIC BALLAST. 277VAC. NOTE 3 N/A VERIFY ON LIGHTING PLANS D - DATA 32 1 NUMBER ADJACENT OF CABLES SIMKAR TO SYMBOL DEFINES THE QUANTITY SM,BM SILVER OR BRONZE MIRROR THE FULL HEIGHT AND WIDTH OF THE COLUMN FROM r - - -' FLOOR TO CEILING. IF A BASEBOARD IS PRESENT, THEN MIRROR HEIGHT IS FROM 28 1 F21T5/830 THE BASEBOARD TO CEILING. FURNISHED AND INSTALLED BY OTHERS. MM- 1- 21- B12 -MN SIMILAR TO TYPE L4 EXCEPT 3' IN LENGTH. NOTE 3. N/A MOTORIZED FIRE SMOKE DAMPER. REFER DETAIL BELOW FOR MORE INFORMATION. L.. :Iik 20 1 F14T5/830 SIMKAR COORDINATE WITH MECHANICAL CONTRACTOR. SIMILAR TO TYPE L4 EXCEPT 2' IN LENGTH. NOTE 3. N/A VERIFY ON POWER PLANS DOME CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED BY EC.. 44 FIXED CAMERA FURNISHED BY OTHERS, INSTALLED AND WIRED BY E.C.. REVISIONS_ 1 No changes shall made ade to the scono of work without prior approval of Tukwila Building Division NOTE: Revisions will require a new plan subm"snl and may include additional plan revi'vr ¢pes FILE OPY Permit No. Plan review approval Is stied to errors and onus Approval of 0- the violation of any adopted � or Is Of approved Fleld r � r �- LIGHTING FIXTURE SCHEDULE (277V) TYPE LOAD (VA) LAMPS MANUFACTURER CATALOG NUMBER DESCRIPTION H &M CATALOG NUMBER APPROXIMATE FIXTURE COUNT Na. TYPE A 46 1 CDM35/T6/830 SPECIALTY LIGHTING 6MHT639E4N /AHTC6ISCLPF ITEM 1:91108ES ACCESSORIES: 0- 64363, 1951 6' RECESSED 39W METAL HALIDE DOWNLIGHT WITH SEMI - DIFFUSE ALUMINUM HAMMERTONE REFLECTOR, CLEAR GLASS LENS, AND WHITE TRIM RING. 277VAC. NOTE 1 91108ES 226 B2 92 2 CDM35/T4/830 SPECIALTY LIGHTING 2HDMT439EWDBWB ITEM j:US12S ACCESSORIES: 1951 2-LAMP 39W METAL HALIDE ADJUSTABLE ACCENT FIXTURE WITH ELECTRONIC BALLAST. 277VAC NOTE 1 911603 32 C 44 1 PLT42 /30/4P /ALTO SPECIALTY LIGHTING 6VF142TE4-- EM /6VFSCL ITEM t:US1400ES ACCESSORIES: 0- 20888, 1951 6' RECESSED 42W COMPACT FLUORESCENT OPEN DOWNUGHT WITH INTEGRAL EMERGENCY BATTERY PACK AND INTEGRAL TEST SWITCH CLEAR ALZAK REFLECTOR AND WHITE TRIM RING. 277VAC NOTE 1 US1400ES 59 D 79 1 CDM70/ r6 /830 SPECIALTY LIGHTING 6MHT670E4N /AHTC61 SCLPF ITEM 1:911041 ACCESSORIES: 0- 64361, 1951 6" RECESSED 70W METAL HALIDE DOWNUGHT WITH SEMI - DIFFUSE ALUMINUM HAMMERTONE REFLECTOR, CLEAR GLASS LENS, AND WHITE TRIM RING. 277VAC. NOTE 1 911041 4 D2 170 1 CDM150/T6/830 SPECIALTY LIGHTING 6MHT6150E4N /AHTC61SCLPF ITEM 1:911044 ACCESSORIES: 0- 64361, 1951 6" RECESSED 150W METAL HALIDE DOWNUGHT WITH TWIN HID ALTERNATING SYSTEM ,SEMI - DIFFUSE ALUMINUM HAMMERTONE REFLECTOR, CLEAR GLASS LENS, AND WHITE TRIM RING. 277VAC. NOTE 1 911044 5 El 45 1 CDM35/`r4/830 SPECIALTY LIGHTING 4MHT439E4 /AHTC4WDSCLPF ITEM 1:91106 ACCESSORIES: 0- 64882, 1951 4.5" RECESSED 35W METAL HALIDE DOWNLIGHT WITH SEMI - DIFFUSE ALUMINUM HAMMERTONE SUNRISE OPTIC REFLECTOR, CLEAR GLASS LENS, AND WHITE TRIM RING. 277VAC. NOTE 1 91106 26 G 64 2 F32T8 /830 /ALTO DAY - BRITE T232- UNV- 1 /2- EB10I/ FKR- 126, WITH LAMP (ADD "E5' AS REQUIRED) 4' -0' LONG CHAIN MOUNTED FLUORESCENT FIXTURE. WITH ELECTRONIC BALLAST. NOTE 3 N/A VERIFY ON LIGHTING PLANS H 96 3 F32T8 /830 /ALTO DAY -BRITS 2TG8332- 21 -UNV- 1 /3 -EB1OI (ADD 15' AS REQUIRED) 2'x4' RECESSED FLUORESECNT FIXTURE WITH WITH .125' ARCYLIC PRISMATIC LENS, FLAT STEEL DOOR AND ELECTRONIC BALLAST. 277VAC. NOTE 3 N/A VERIFY ON LIGHTING PLANS L4 32 1 F28T5/830 SIMKAR MM- 1- 28- B12 -UNV SMALL PROFILE, FLUORESCENT STRIP WITH 1 LAMP IN CROSS SECTION, INTEGRAL T5 ELECTRONIC BALLAST. FIXTURE SHALL BE 4' IN LENGTH, OVERLAP UNITS SLIGHTLY FOR EVEN ILLUMINATION. 120V. NOTE 3. N/A VERIFY ON POWER PLANS L3 28 1 F21T5/830 SIMKAR MM- 1- 21- B12 -MN SIMILAR TO TYPE L4 EXCEPT 3' IN LENGTH. NOTE 3. N/A VERIFY ON POWER PLANS L2 20 1 F14T5/830 SIMKAR MM- 1- 14-- 812 -UW SIMILAR TO TYPE L4 EXCEPT 2' IN LENGTH. NOTE 3. N/A VERIFY ON POWER PLANS P 44 1 CDM35/T6 /830 NORDIC LIGHT 054 - 524-20 39W METAL I-IALIDE DECORATNE PENDANT FURNISHED BY H &M, INSTALLED AND WIRED BY EC. 120VAC. NOTE 1. 91151 57 P1 79 1 CDM70/T6 /830 NORDIC LIGHT 054- 516 -20 70W METAL HALIDE DECORATNE PENDANT FURNISHED BY H &M, INSTALLED AND WIRED BY EC. 120VAC. NOTE 1. 91155 2 S 96 3 F32T8 /830 /ALTO DAYBRITE AWW332- 277 - 1/368101 (ADD"E5 AS REQUIRED) SURFACE MOUNTED FLUORESECNT FIXTURE WITH ARCYIIC PRISMATIC LENS AND ELECTRONIC BALLAST. 277VAC NOTE 3 N/A VERIFY ON LIGHTING PLANS T T1 45 1 SEE T1, T2 FOR TRACK HEAD INFORMATION CDM35/`r6 /830 SPECIALTY LIGHTING SPECIALTY LIGHTING T42 RECESSED 3- CIRCUIT 39E -3GRAY ITEM H:91006104 ACCESSORIES: 0 -64361 142' STYLE RECESSED 3- CIRCUIT LIGHT TRACK WITH WHITE FINISH AND ALL RELATED ACCESSORIES, FEEDS, CONNECTORS, ETC. INCLUDING RECESSED JACKET ASSEMBLY AND ITS ACCESSORIES. NOTE 1 39W METAL HALIDE TRACK HEAD NOTES 1 & 2 US17, US17B, 77578 1831' VERIFY WITH H &M PROJECT MANAGER EX1 5 - WITH UNIT UTHONIA LRP- X -RC -X- 120/277- EL N -X LED. EDGE -LIT EXIT SIGN WITH STENCIL FACE, RED LETTERS, CLEAR FACE, BRUSHED ALUMINUM HOUSING, UNIVERSAL MOUNTING AND EMERGENCY BATTERY PACK SINGLE OR DOUBLE FACE AND ARROWS AS INDICATED ON PLANS. N/A VERIFY ON LIGHTING PLANS 0(2 5 - WITH UNIT UTHONIA LQMSW3R120 /277 LED. EXIT SIGN WITH STENCIL FACE, RED LETTERS, WHITE POLYCARBONATE FACE AND HOUSING, UNIVERSAL MOUNTING AND EMERGENCY BATTERY PACK SINGLE OR DOUBLE FACE AND ARROWS AS INDICATED ON PLANS. N OTT 3. � � - N/A VERIFY ON LIGHTING PLANS EM3 70 - 35W MR16 WITH UNIT LTTHONIA VEL1270 (LAMP H3512) 12V ADJUSTABLE MR16 35W CONCEALED EMERGENCY FIXTURE W/ WHITE FINISH. FINISH SHALL BE FIELD PAINTED TO MATCH CEILING COLOR. STANDARD SELF - DIAGNOSTIC. 120/277VAC. NOTE 3. N/A VERIFY ON LIGHTING PLANS FIXTURE SCHEDULE NOTES 1. 2. City of Tukwila BUILDING DIVISION FIXTURE AND LAMPS FURNISHED BY H & M, AND INSTALLED AND WIRED BY EC. (TYPES A, B2,C,D,D2,E1,P,P1,T,T1) VERIFY INSTALLATION LOCATION WITH H & M REP. THE EC. SHALL INCLUDE IN HIS BID, THE LABOR COST TO INSTALL APPROX. 400 TRACK FIXTURES. LIGHT FIXTURES, EXIT SIGNS, AND LAMP(S) FURNISHED, INSTALLED AND WIRED BY EC.. ACCEPTABLE ALTERNATE MANUFACTURERS SHALL BE TYPE G, H, S: TYPE EX1, 0(2, TYPE L4, L3, 12: Q UTHONIA, METALUX, DAY- BRITE, HUBBELL SUREIITES, EMERGI -CITE, LITHONIA LEGION (MICRO -STRIP 1600 SERIES) 4. SHADED SALES LIGHT FIXTURES AND HALF- SHADED NON -SALES LIGHT FIXTURES ON THE E2 SERIES DRAWINGS SHALL BE PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. SEPARATE PERMIT REQUIRED FOR: Te Mechanical Cl Electrical 1- Plumbing L,Gas Piping City of Tukwila BUILDING DIVISION APPROVE) P! ' • ':T r 'Tfl OAT'ON7. 7!'!".1.1 P' T 77 ^ "t °: ". MODIFIED OR ALTERED? WITHOUT AUTHORIZATION FROM THE BUILDING Or''!^;AI , ALI WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND Is TO FIE! C INSPECTIONS GENERAL NOTES 1. FINAL CONNECTIONS TO ALL LAY -IN FIXTURES AND RECESSED INCANDESCENT FIXTURES IN LAY -IN CEILINGS ARE TO BE MADE WITH GREENFIELD FLD(IBLE CONDUIT. 2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHT FIXTURE LAY -OUT. CONTRACTORS TO CORRELATE LOCATIONS OF LIGHTING, SPEAKERS, AIR DIFFUSERS, GRILLES, AND THE LIKE, WITH REFLECTED CEILING LAY -OUTS AS REQUIRED AND DIRECTED BY THE ARCHITECT. 3. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN AND /OR ROOM FINISH SCHEDULE TO DETERMINE PROPER TYPE OF LIGHT FIXTURE REQUIRED FOR THE CEILING CONSTRUCTION PRIOR TO ORDERING THE FIXTURES AND SHALL PROVIDE FIXTURES THAT ARE COMPATIBLE WITH THE CEILING SYSTEM. 4. ALL DEVICES, EQUIPMENT, FIXTURES, AND THE LIKE, MUST BE GROUNDED BY USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. MECHANICAL/ ELECTRICAL BONDS OF THE METAWC RACEWAY SYSTEM SHALL ALSO BE MAINTAINED. 5. REFER TO MECHANICAL PLANS FOR EXACT LOCATION OF MECHANICAL EQUIPMENT AND LOCATE DISCONNECT SWITCHES IN ACCORDANCE WITH THE NEC. 6. REFER TO DN. 15 SPECIFICATIONS, HVAC PLANS AND PLUMBING PLANS FOR ADDMONAL ELECTRICAL WORK AND REQUIREMENTS. 7. ALL RECEPTACLES SHOWN 13ACK -T0 -13ACK IN WALLS SHALL BE SEPARATED BY 8" MINIMUM. 8. WIRING IN PLENUMS SHALL BE PLENUM RATED OR INSTALLED IN CONDUIT. 9. BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES NOT EXCEED A LIMIT OF 3 %. 10. WIRE SIZES SHALL BE BASED ON THE 60'C. AMPACITIES FOR WIRE SIZES NO. 14 -1 AWG, AND 75'C. AMPACIIIES FOR WIRE SIZES 11/0 AWG AND LARGER. 11. CIRCUITS MAY BE MUL11- PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY DERATED AND CONDUIT SIZED PER CODE UNDER NO CIRCUMSTANCES SHALL MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. 12. ALL CONDUITS SHALL CONTAIN A GROUND WIRE SIZED PER NEC TABLE /250 -122. IN ADDITION, WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED, A SEPARATE GREEN GROUND SHALL BE RUN FROM THE PANEL GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE. IN NO CASE SHALL THE SYSTEM GROUND (WIRE AND ASSOCIATED OUTLET BOXES, CONDUIT AND BUILDING STEEL) BE ALLOWED TO CONTACT THE ISOLATED GROUND (GREEN WIRE AND DEVICE). WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE FOR VOLTAGE DROP, THE GROUND WIRE SIZE SHALL BE INCREASED PROPORTIONATELY (ACCORDING TO CIRCULAR MIL AREA) FROM THE SIZE REQUIRED BY NEC TABLE 1250 -122. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR B1_1Q FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. ALLOWED. THIS APPLIES TO ALL ELECTRICAL SYSTEMS, INCLUDING POWER, LIGHTING, CONTROL HVAC, SECURITY, DATA, PHONE, ETC. REWE7EaED FCR-` CODE COMPLIANCE APPROVED MAR 2 5 2008 LOCATION OF NAMEPLATE FOR SURFACE MOUNTED PANELS. FOR FLUSH- MOUNTED PANELS, INSTALL NAMEPLATE BEHIND DOOR. ENGRAVED LAMACOID, 5/32' LETTERS, SECURE TO PANEL BOARD COVER WITH ADHESIVE TYPE FASTENER. 3' EQUIPMENT DESIGNATION NOTE NAMEPLATES ARE REQUIRED ON ALL SWITCHBOARDS, DISTRIBUTION PANELS, PANEL BOARDS, STARTERS, DISCONNECT SWITCHES, RELAYS AND JUNCTION BOXES GREATER THAN 4 11/16' SQUARE. ALSO PROVIDE NAMEPLATES ON BRANCH SWITCHES OF SWITCHBOARDS AND DISTRIBUTION PANELS. STANDARD COLORS; 1. NORMAL POWER - BLACK BACKGROUND, WHITE LETTERS 2. EMERGENCY POWER - RED BACKGROUND, WHITE LETTERING 3. IN ADDITION TO THE FUNCTION NAMEPLATE, PROVIDE NAMEPLATES IDENTIFYING ALL "MAIN SERVICE NAMEPLATE DISCONNECTS' - RED BACKGROUND - WHITE LETTERING NAMEPLATE DETAIL NO SCALE COMMISSIONING REQUIREMENTS: FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, AUTOMATIC SHUT -OFF CONTROLS, OCCUPANCY SENSORE, OR AUTOMATIC TIME SWITCHES, THE LIGHTING CONTROLS SHALL BE IESIkI TO ENSURE THAT CONTROL DEVICES, COMPONENTS, EQUIPMENT AND SYSTEMS ARE CALIBRATED, ADJUSTED AND OPERATE IN ACCORDANCE; WITH APPROVED PLANS AND SPECIFICATIONS. SEQUENCES OF OPERATION SHALL BE FUNCTIONALLY TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS AND SPECIFICATIONS. A COMPLETE REPORT OF TEST PROCEDURES AND RESULT SHALL BE PREPARED AND FILED WITH THE OWNER. DRAWING NOTES SHALL Rt4UIREI COMMISSIONING IN ACCORDANCE WITH THIS PARAGRAPH. Pubic Works, Bulling Division PERMIT NUMBER CORRECTION LT R# US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659 -6688 Ph. (330) 659 -6675 Fax mummemmimumni QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 ADDENDUM A RECEIVED l:l I r Vr i unvar+�+ MAR 19 2008 PERMIT CENTER Project No. Scale DravnBy: 43328 AS NOTED JDM Y: \2008 \2008 -0049 \Cad \Mep \RecordSet \ADDENDUM A \2008- 0049E0-i4d Drawing No. ELECTRICAL LEGENDS AND SCHEDULES -1'°1-222' TILE COgQ.1 Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:26 pm Plotted Monday April 14, 2008 1:26pm by gsimon PANELBOARD DESIGNATION HP1 480/277 VOLTS PH. WIRE SOLID AMPERE MAIN POWERLINK NEUTRAL LUGS ONLY MOUNTING: FLUSH = nSURFACE IL AIC = 16.256A ! \ 125 AMPERE BUS 125 SPECIAL REQUIREMENTS MASTER PANEL. POWERUNK POWER SUPPLY 800A/3P POWERUNK LEVEL 3000 CONTROLLER N KVA DESCRIPTION A B C ^ ' DESCRIPTION KVA 3 1 3 0.2 EMERG /EXIT LIGHTING ^- 0.8 PANEL HP1 SALES LIGHTING - 1ST 0.6 2 4 I DOUBLE BRANCH IWH -A 5 0.6 CLEANING LTG - 1ST 60A DOUBLE BRANCH EMERG /EXIT LIGHTING 0.2 ^ 08 60A DOUBLE BRANCH IWH -A 5 7 0.3 EMERG /EXIT LIGHTING 60A 8 -'- FETING RM STALL LTG 1ST 0.5 6 Y25A 50A/1P _ 60A 1 0 VAV -1 -1 ^- 1.8 CLEANING LTG -- 2ND ^-1 3 HAC.R. RATED SALES LGI-111NG - 2ND 1.9 8 10 7 1 60A ''- ^ ---1 ' 11 9 11 0.3 EMERG /EXIT LIGHTING 0 VAV -2 -1 EMERG /EXIT LIGHTING 0.2 5 I 60A HAC.R. RATED 0.5 CLEANING LTG - 2ND 9.8 9 -' ' SALES UGHTING - 2ND 0.4 12 14 -' 10.8 0 60A ^- 8 1-' ' 13 2.9 CLEANING LTG - 2ND ''-1 3 60A EMERG /EXIT LIGHTING 0.1 0 1 13.8 ' ' 60A 15 17 0.3 EMERG /EXIT LIGHTING 3.5 3 F-----"- SALES UGHTING - 2ND 3.0 16 18 1 3 20A/1P 1.9 CLEANING LTG - 2ND VAV -2 -8 SALES UGHTING - 2ND 1.9 18 20 -'' HAC.R. RATED 1 3 20 ' ' 19 21 0.4 EMERG /ENT UGHTING ^-1 0 21 EMERG /EXIT LIGHTING 0.3 7 1 DOUBLE BRANCH ^- 9 1---- ' 0.2 CLEANING LTG - 2ND 1 DOUBLE BRANCH SALES UGHTING - 2ND 2.2 22 24 '~ 2 4 1 BUSSED SPACE 23 25 0.6 EMERG /EXIT LIGHTING 100A EMERG /EXIT LIGHTING 0.3 25 - 1 0 100A ' ' 1.8 B -O -H LTG '"-1 2 2 FITTING RM STALL LTG 2ND 0.6 26 4 ( TRACK LIGHTING ^- LIGHTING 27 29 0.1 EMERG /EXIT LIGHTING 01 1 CONTROLLABLE SPARE - 28 27 1.8 TRACK LIGHTING 3 0.6 STOCK LIGHTING 1.8 6 1-^ CONTROLLABLE SPARE - 30 -'' 1.8 1 0 Ill '" 31 - CONTROLLABLE SPARE ^-L 1 CONTROLLABLE SPARE - 32 - TRACK UGHTING '.-N---- TRACK LIGHTING 33 - CONTROLLABLE SPARE ' 32 CONTROLLABLE SPARE - 34 TRACK LIGHTING -1 TRACK LIGHTING 1.8 34 35 - SPACE 6 1- -'TRACK F- - SPACE - 36 - 1 KVA SUB 1.8 36 TOTALS 10.61 7.8 1 7.0 " -TRACK "-TRACK . TOTAL CONNECTED LOAD 25.4 KVA "-TRACK -"--\ 37 DISTRIBUTION PANEL LOAD SUMMARY NAME MDP VOLTAGE 480Y/277V -30 -4W BUSSING: 800A M.C.B. 800A/3P TYPE SQ D DIST. PANEL MAIN DEVICE: 800A /3P AIC = 17,678A n LOAD N0. KWD 51E FRAME NOTES 800A MAIN BREAKER 1 - 800A/3P 800A 151- r TRANSFORMER T1 2 142.5 Q 225/3P 400A DOUBLE BRANCH TRANSFORMER T2 3 & 51.4 0 125/3P 200A DOUBLE BRANCH PANEL HP1 4 25.4 100/3P 100A DOUBLE BRANCH IWH -A 5 5.5 25A/1P 60A DOUBLE BRANCH IWH -A 6 5.5 25A/1P 60A DOUBLE BRANCH IWH -A 7 5.5 /1P 60A DOUBLE BRANCH IWH-B 8 11.1 Y25A 50A/1P _ 60A DOUBLE BRANCH VAV -1 -1 9 7.3 35A/1P 60A HAC.R. RATED VAV -1- -2 10 8.3 40A/1 P 60A HAC.R. RATED VAV -1 -3 11 7.3 35A/1 P 60A HAC.R. RATED VAV -2 -1 12 15.3 25A/3P 60A HAC.R. RATED VAV -2 -2 13 9.8 45A/1P 60A HAC.R. RATED VAV -2 -3 14 10.8 50A/1 P 60A HAC.R. RATED VAV -2 -4 15 9.8 45A/1 P 60A HAC.R. RATED VAV -2 -5 16 13.8 60A /3P 60A HAC.R RATED VAV-2-6 17 3.5 20A /1P 60A HAC.R. RATED VAV -2 -7 18 3.5 20A/1P 60A HAC.R. RATED VAV -2 -8 19 2.0 10A/1 P 60A HAC.R. RATED VAV -2 -9 20 7.0 35A/1P 60A HAC.R. RATED ESCALATOR 1 21 28.2 70A /3P 100A DOUBLE BRANCH ESCALATOR 2 22 28.2 70A /3P 100A DOUBLE BRANCH ELEVATOR 23 43.2 90A/3P 100A DOUBLE BRANCH BUSSED SPACE 24 - 100A /3P 100A DOUBLE BRANCH BUSSED SPACE 25 - 100A /1P 100A DOUBLE BRANCH 24 TOTAL 0 2 444.9 NOTES: PROVIDE "DOUBLE BRANCH" BREAKERS WHEREVER POSSIBLE (SIDE BY SIDE MOUNTED). PROVIDE PANEL SECTIONS AS REQUIRED. MAIN BREAKER AND BUSSING SHALL BE RATED AT 100% OF THEIR AMPACITY. 10 10 10 Z2 Z2 Z2 Z2 Z2 F9-1 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 PANELBOARD DESIGNATION LP1 (section 1) _ 225 AMPERE BUS J AMPERE MAIN SURFACE 120 /208 VOLTS PH. WIRE SOLID AMPERE MAIN POWER UNK SLAVE NEUTRAL BREAKER AIC MOUNTING: FLUSH _ = 9,739A A SURFACE THRU LUGS 400- AMPERE BUS 400 SPECIAL REQUIREMENTS PANEL FEED 151- r KVA DESCRIPTION A B C '- DESCRIPTION KVA C ' 1 1.8 TRACK LIGHTING - '`--� 3.6 0.4 TRACK LIGHTING 1.8 2 0.4 2 '' 3 1.8 TRACK LIGHTING '� 3 TRACK LIGHTING 1.8 4 46 3 6 6 1-^- 4 5 1.8 TRACK LIGHTING LIGHTING TRACK LIGHTING 1.8 6 SECURITY JBOX 0 3 SECURITY QUAD I.G. ' ' 7 1.8 TRACK LIGHTING _.--....d 3 LIGHTING TRACK LIGHTING 1.8 8 6 1 ^-1 0 ^ ^ --1 0.2 9 1.8 TRACK LIGHTING 3 "-I ^ TRACK LIGHTING 1.8 10 6 1 6 1-"- 8 11 1.8 TRACK LIGHTING 3 H'-TRACK TRACK LIGHTING 1.8 12 L 0 6 DECO I.G. 1 3 12 '- '`- 13 1.8 TRACK LIGHTING - - ^- 3 6 1 TRACK LIGHTING 1.8 14 DECO I.G. 0.4 ^-1 57 15 1.8 TRACK LIGHTING 3 0.2 TRACK LIGHTING 1.8 16 6 1 0.4 17 1.8 TRACK LIGHTING TRACK LIGHTING 6 1-'- TRACK LIGHTING 1.8 18, -' 0 8 1 3 0.6 '- 19 0.6 TRACK UGHTING ^-J 24 - TRACK LIGHTING 1.8 20 ^ 1 6 ( I.G. CASH WRAP RECEPTS ^-- --1 20 21 0.6 TRACK UGHI1NG 2 4 1 --- TRACK LIGHTING 1.8 22 -'- 4 (- ^- ^ 23 0.6 TRACK LIGHTING 1 TRACK LIGHTING 1.8 24 -' 0.2 2 0 '-'- 25 1.8 TRACK LIGHTING -' -I 3 LIGHTING TRACK UGHTING 1.8 26 6 I ^ 1 '- '-,,-1 0.6 27 1.8 TRACK LIGHTING 3 UGHTING TRACK LIGHTING 1.8 28 6 1 0.6 28 29 1.8 TRACK UGHTING Ill 6 1-'- TRACK LIGHTING 1.8 30 -' 8 1 3 0.6 31 1.8 TRACK UGHTING -' -1 3 6 I- ---- TRACK LIGHTING 1.8 32 -- ' 32 8 33 1.8 TRACK LIGHTING 1 TRACK LIGHTING 1.8 34 ' ' 3 6 6 1- -'TRACK HOL I.G. CASH WRAP 35 1.8 TRACK LIGHTING 0.6 LIGHTING 1.8 36 1 0 " -TRACK "-TRACK 1 3 0.4 "-TRACK -"--\ 37 1.8 TRACK LIGHTING '-`-1 3 80 LIGHTING 1.8 38 6 I 81 ^ 39 1.8 TRACK LIGHTING 8 6 } TRACK LIGHTING 1.8 40 -' -"---1 3 El 41 1.8 TRACK LIGHTING 3 6 (- ^-'TRACK LIGHTING 1.8 42 - • I PANELBOARD DESIGNATION LIGA 2) _ 225 AMPERE BUS J AMPERE MAIN SURFACE 208/120 VOLTS PH. BUS WIRE SOUD AMPERE MAIN INSULATED /ISOLATED NEUTRAL BREAKER MOUNTING: FLUSH SURFACE BAR, 200% NEUTRAL .X_ AMPERE SPECIAL REQUIREMENTS GROUND 1•tt) THRU LUGS FOR 1VSS UNIT, AIC = 1,065A / ^ \ Na KVA DESCRIPTION A B C ' DESCRIPTION KVA E. 1 0.4 SOUND EQUIPMENT ^-1 0.8 1-- HOL I.G. CASH WRAP 0.4 2 I ^-1 -' '- I-' ^- -'- ^- '- '` TRACK LIGHTING 3 3 0.4 DATA RACK 46 8 HOL I.G. CASH WRAP 0.4 4 '. 0 6 -' "TRACK LIGHTING 1.8 5 0.4 SECURITY JBOX 0 8 SECURITY QUAD I.G. 0.4 6 TRACK LIGHTING ''---1 2 3 ( LIGHTING 1.8 7 0.4 CASH OFFICE I.G. ^-1 0 ^---1 ' ' EMPLOYEE 11MECLOCK 0.2 8 6 1 I--"- "-I ^ 52 9 0.4 CASH OFFICE I.G. 0 8 CASH OFFICE DOOR I.G. 0.4 10 3 H'-TRACK 11 0.4 CASH OFFICE I.G. L 0 6 DECO I.G. 0.6 12 55 6 (- TRACK LIGHTING - 3 CONTROLLABLE SPARE 13 0.4 SECURITY RECEPT. ''-1 0 DECO I.G. 0.4 14 57 -'- ^ CONTROLLABLE SPARE 15 0.2 SENSORMAIIC RECEPT 58 6 DECO I.G. 0.4 16 '~ 0 TRACK LIGHTING 1 6I-' 'TRACK 17 0.2 MANAGER'S OFFICE I.G. 0 8 I.G. CASH WRAP RECEPTS 0.6 18 ^- -TRACK 61 1.8 TRACK LIGHTING -'-,H 3 0.8 0.4 SOUND EQUIPMENT _ ^ 1 6 ( I.G. CASH WRAP RECEPTS 0.6 20 0 J �� di 1.8 TRACK LIGHTING 3 '� ^- '- LIGHTING 1.8 0.2 BACK DOOR I.G. �r ^ 65 I.G. CASH WRAP RECEPTS 0.6 22 6 (-"-TRACK LIGHTING 1.8 66 0.2 SENSORMATIC RECEPT 0 8 I.G. CASH WRAP RECEPTS 0.6 24 CONTROLLABLE SPARE LIGHTING 1.8 IA 0.4 SOUND EeUIPMENT ^ 1 ^ --) ^ I.G. CASH WRAP RECEPTS 0.6 26 0 1 r� ir 3 1 UGHTING 0.2 BACK DOOR I.G. ' ^ CASH WRAP RECEPTS 0.6 28 TRACK LIGHTING -1.G. ' -1.G. ' " Ill • 0.2 BACK DOOR I.G. ■ ^ 0 8 CASH WRAP RECEPTS 0.6 30 ^-J 3 CONTROLLABLE SPARE 0.4 SOUND EQUIPMENT ''-1 0 6 1 HOL I.G. CASH WRAP 0.4 32 8 TRACK UGHTING 0.9 ITA ' ^ 76 6 1 0.2 BACK DOOR I.G. 1.8 TRACK LIGHTING HOL I.G. CASH WRAP 0.4 34 ^ 0.6 - 0.5 FAC.P 1 0 " -TRACK "-TRACK HOL I.G. CASH WRAP 0.4 6 ',-1 3 I LIGHTING 1.6 80 37 0.4 SOUND EQUIPMENT ^-1 0 81 ^ SOUND EQUIPMENT 0.4 38 8 82 ....-.. 3 2 1 ^ 83 El 0.5 TEMP. CTL PANEL 2 F =TRACK LIGHTING 5 84 S'AR - • I PANEL UGA 0 '- Fr I-' CONNECTED LOAD 142.5 KVA 41 - SPARE 41 - SPARE - 42 i KVA SUB TOTALS ^- AI A Q 5.6 4.9 TOTAL CONNECTED LOAD ( 15.2 KVA 12.6 11.0 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 7.2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 TC -1 TC -1 TC -1 Z1 Z2 Z2 Z2 Z2 Z2 Z2 PANELBOARD DESIGNATION LP1 (section 2) _ 225 AMPERE BUS J AMPERE MAIN SURFACE 120/208 VOLTS 1 PH. WIRE SOLID AMPERE MAIN POWER UNK SLAVE NEUTRAL LUGS ONLY MOUNTING: FLUSH _ SURFACE IL = 9,739A Q _a_ AMPERE BUS 400 SPECIAL REQUIREMENTS PANEL, AIC Par KVA DESCRIPTION A B C "-TRACK -TRACK DESCRIPTION KVA NNo. 43 1.8 TRACK LIGHTING ' '- 3.6 PENDANT LIGHTING LIGHTING 1.8 44 ( I ^-1 45 1.8 TRACK LIGHTING 3 1.0 UGH1ING 1.8 46 6 I 47 1.8 TRACK LIGHTING 3 6 -' "TRACK LIGHTING 1.8 48 6 15 }-' ' 1 1.6 "-TRACK '- 49 0.5 TRACK LIGHTING ''---1 2 3 ( LIGHTING 1.8 50 5 1 -- -- ^- ^---1 ' ' 51 0.5 TRACK LIGHTING EWC 1 TRACK LIGHTING 1.8 52 -' - ^2 2 3 1 1 53 0.5 TRACK LIGHTING 1-.. ^- ^- 3 H'-TRACK LIGHTING 1.8 54 ---- -1 2 EF-2 '- ^- 55 1.8 TRACK LIGHTING - 3 CONTROLLABLE SPARE TRACK LIGHTING 1.8 56 6 ( '"- ^ - 57 1.8 TRACK LIGHTING CONTROLLABLE SPARE - TRACK LIGHTING 1.8 58 1 7 3 6 0.8 59 1.8 TRACK LIGHTING 1 6I-' 'TRACK UGHTING 1.8 60 19 - 3 -' '-1 ^- -TRACK 61 1.8 TRACK LIGHTING -'-,H 3 0.8 TRACK LIGHTING 1.8 62 6 ( -; ^--1 '-‘-- T-•- CONTROLLABLE SPARE 63 1.8 TRACK LIGHTING 3 22 LIGHTING 1.8 64 6 1 CONTROLLABLE SPARE 65 1.8 TRACK UGHTING -1 3 6 (-"-TRACK LIGHTING 1.8 66 '~ ' 67 1.8 TRACK LIGHTING -'�H 3 CONTROLLABLE SPARE LIGHTING 1.8 68 6 ( -TRACK "-TRACK ^ --) ^ CONTROLLABLE SPARE 69 1.8 TRACK LIGHTING 3 1 UGHTING 1.8 70 6 71 1.8 TRACK LIGHTING 6 1-' -TRACK ' -TRACK ' -TRACK UGHTING 1.8 72 29 0.5 1 3 31 73 1.8 TRACK LIGHTING ^-J 3 CONTROLLABLE SPARE LIGHTING 1.8 74 6 1 '"- '-"--1 ^ 75 1.8 TRACK UGHTING 3 32 UGHTING 1.8 76 6 1 -1 77 1.8 TRACK LIGHTING - 6 -' "TRACK UGHTING 1.8 78 - 36 1 3 1 0 " -TRACK "-TRACK 79 1.6 TRACK LIGHTING ',-1 3 I LIGHTING 1.6 80 2 ' ' 81 1.6 TRACK LIGHTING 15 KVA XFMR LIGHTING 1.6 82 ....-.. 3 2 1 ' 83 1.6 TRACK LIGHTING 2 F =TRACK LIGHTING 1.6 84 3 KVA SUB SPARE PANEL UGA TOTALS 47.5 Kin '- TOTAL CONNECTED LOAD 142.5 KVA PANELBOARD DESIGNATION LP3 208 /120 VOLTS PH. WIRE SOLID NEUTRAL MOUNTING: FLUSH _ 225 AMPERE BUS J AMPERE MAIN SURFACE 120/208 VOLTS 3_ PH. WIRE SOLID AMPERE MAIN POWER LINK SLAVE NEUTRAL BREAKER MOUNTING: FLUSH ^ SURFACE _ = 5,571A LA\ 125 AMPERE BUS 100 SPECIAL REQUIREMENTS PANEL, AIC re. KVA DESCRIPTION A B C ^- ''- DESCRIPTION KVA 2 1 1.3 PENDANT LIGHTING ' '-1 2.6 NONCONTINUOUS LOAD 0100% = PENDANT LIGHTING 1.3 2 I 1.0 3 0.6 POP -OUT WALL LIGHTING -''J ^ POP -OUT WALL LIGHTING 1.0 4 1 6 I 5 0.8 POP -OUT WALL LIGHTING 5 1-'- POP -OUT WALL UGHTING 0.8 6 6 15 }-' ' 1 1.6 ' ' 7 1.3 MIRROR LIGHTING - 2ND ^-1 2 REFRIGERATOR SIGN 1.2 8 5 1 -- -- ^- ^---1 ' ' 9 0.8 EWC 2 01 --- SIGN 1.2 10 1 1 0.8 W A T E R COOLER DECO ROOM 1-.. ^- ^- TEMP. CONTROL RELAY 0.2 12 - 13 1 1.0 EF-2 13 - CONTROLLABLE SPARE ^-J 0 0 7 CONTROLLABLE SPARE - 14 8 I '"- 15 - CONTROLLABLE SPARE -1 + CONTROLLABLE SPARE - 16 ---- ^--1 1 1 7 17 0.8 EWC 0 8 1-^- CONTROLLABLE SPARE - 18 SHOW WINDOW RECEPT ^ 19 - CONTROLLABLE SPARE -' '-1 --1 4 CONTROLLABLE SPARE - 20 - 1 0.8 '' 21 - CONTROLLABLE SPARE -; CONTROLLABLE SPARE - 22 1 - 22 - �-1 23 - CONTROLLABLE SPARE 23 25 27 CONTROLLABLE SPARE - 24 0.2 24 -^ '~ 25 - CONTROLLABLE SPARE ^-1 26 CONTROLLABLE SPARE - 26 - I 19 27 - CONTROLLABLE SPARE CONTROLLABLE SPARE - 28 ^H ELEV PIT LTG / RECEPT 0.5 28 29 - CONTROLLABLE SPARE - 1-'~ CONTROLLABLE SPARE - 30 29 0.5 '- '' 31 - CONTROLLABLE SPARE -''-1 - CONTROLLABLE SPARE - 32 ( '"- 31 33 - CONTROLLABLE SPARE 1.0 32 CONTROLLABLE SPARE - 34 ---- ^-- -1 1 35 - CONTROLLABLE SPARE EF -1 1- - CONTROLLABLE SPARE - 36 - ---- -1 1 0 INA SUB TOTALS Q 5.1 1 3.6 1 3.4 0 0.5 TOTAL CONNECTED LOAD 12.1 KVA - 36 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2 TC -1 TC -1 TC -1 Z2 Z2 Z2 TC -1 TC -1 Z1 10 10 PANELBOARD DESIGNATION LP2 208 /120 VOLTS PH. WIRE SOLID NEUTRAL MOUNTING: FLUSH _ 225 AMPERE BUS J AMPERE MAIN SURFACE _BREAKER g SPECIAL REQUIREMENTS AIC = 5,086A 0 W. KVA DESCRIPTION A B C ' ' -' DESCRIPTION KVA I 1 0.8 VENDING B -O-H RECEPT 1.2 2 ^-1 2.0 MISCELLANEOUS: 136.3 NONCONTINUOUS LOAD 0100% = ^ SIGN 22 .44 SALES RECEPTACLES 1.0 4 3 -- SPARE 1 1 0 ^--- COMPUTED SERVICE DEMAND LOAD OF 525.2 VA CO 480/277V -30 -4W = 632.4 AMPS TOTAL NUMBER OF BRANCH CIRCUITS: 193 TOTAL NUMBER OF SPARE CIRCUITS: 40 5 0.9 STOCK RECEPT /DOORBELL SALES RECEPTACLES 0.6 6 15 }-' ' -1 (-- -'- ' ' 1-'-'- ^- ^- 7 0.8 REFRIGERATOR SALES /FITTING RM RECEPT 0.8 8 ^-1 1 6 -- -- --- ^-) -15-- 9 1.2 MICROWAVE MANAGER RECEPT 0.8 10 2.0 1 04 11 0.2 LOUNGE RECEPTACLE DECO ROOM 0.2 12 13 0.5 EF-2 DECO ROOM 0.2 14 T--[ 0 7 15 0.5 + CASH WRAP RECEPTACLES 1.2 16 1 7 - - -`-- 17 1.2 SHOW WINDOW RECEPT CASH WRAP RECEPTACLES 0.8 18 2.0 (-'- -".-1 2 --1 4 1- -" 0 �' ' 6 1-'- ^- ^- " CASH WRAP RECEPTACLES 0.8 20 19 1.6 SHOW WINDOW RECEPT -; 21 1.6 SHOW WINDOW RECEPT SPARE - 22 1 6 �-1 5 23 25 27 0.4 ESP -1 EMPLOYEE CARD SWIPE 0.2 24 -^ -1 ELEVATOR LGTS /CNTRL 1.5 26 0.4 ^-1 19 0.4 ELEV PIT LTG / RECEPT 0.5 28 0 9 29 0.5 ESCALATOR 1 PIT REC /LTC ELEV MACH RM RECEPT 0.4 30 --^ 1 0 9 (-' ^- ' ' 31 0.5 ESCALATOR 2 PIT REC /LTG ELEV PIT HEATER (OPTIONAL) 1.0 32 -15 -1 1 5 ( �� 33 0.5 EF -1 SPARE - 34 0 5 1 0 5 (-60 35 0.5 SPARE - 36 - 37 - SPARE 15 KVA XFMR 5.6 8 42 ^ ( ' ' 5 6 '1 39 - SPARE PANEL UGA 4.9 '- 4 9 41 - SPARE AA 4.7 4 7 ^- KVA SUB TOTALS KIMI 12.6 11.0 AA TOTAL CONNECTED LOAD KVA PANELBOARD NOTES 1. ALL BREAKERS SHALL BE 20A/1P, UNLESS NOTED OTHERWISE. 2. 3. 4. 5. 6. 7. 8. 8. INDICATES BREAKER SHALL BE WI' RATED. INDICATES BREAKER SHALL BE "HACR" RATED. INDICATES BREAKER SHALL BE 30 rnA *C.F.I.* TYPE. INDICATES BREAKER SHALL BE *HID.' RATED. INDICATES BREAKER TO HAVE LOCK -ON CUP. INDICATES BREAKER TO HAVE LOCK -ON CUP AND RED MARKING. POWERUNK EMERGENCY LIGHTING C.B. (REQUIRES 2 SPACES) ELECTRICAL EQUIPMENT AND DEVICES TO BE INSTALLED BY LANDLORD AND CONNECTED TO LANDLORD POWER TEMPORARILY VIA A FUSED DISCONNECT SWITCH WITHIN THE TENANT SPACE. E.C. SHALL PROVIDE A TEMPORARY TRANSFORMER AND PANEL AS REQUIRED UNTIL PERMAMENT ELECTRIC SERVICE IS ESTABLISHED. EC. SHALL THEN RE- CONNECTED TO H&M PANELS AS REQUIRED. COORDINATE WITH LANDLORD EC. IN FIELD. PROVIDE WIRE, CONDUIT, BREAKERS AND MEANS OF DISCONNECT PER MANUFACTURER'S REQUIREMENTS. 9. 1C -1 ", "Z, INDICATES 'ESIGNATION OF POWERUNK ZONE OR TIME CLOCK CONTROLLING CIRCUIT. SEE UGI-I11NG CONTROL SCHEDULE ON E4.2. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ELECTRICAL LOAD SUMMARY LOAD DESCRIPTION CONNECTED LOAD (KVA) COMPUTED DEMAND LOAD (KVA) GENERAL LIGHTING: (LESS THAN 3VA /SQ. FT. CONNECTED) TRACK LIGHTING: 1702 LF INSTALLED 35.5 CONTINUOUS LOAD: 23,590 Sq. Ft. x 3VA /Sq Ft. = CONTINUOUS LOAD: 1035 LF x 75VA /Ft. x 1.25 = 70,8 127.7 159.6 SHOW WINDOW: 129 LF INSTALLED 25.8 123 LF. OF SHOW WINDOW x 200VA /LF x 1.25 = 32,3 I-IVAC: 98.4 CONTINUOUS LOAD: (INCLUDES 125% OF LARGEST MOTOR) = 102.2 RECEPTACLES: 32D NONCONTTNOUS LOAD: 1st 10KW 0100% + REMAINING X5O% = 21,0 MISCELLANEOUS: 136.3 NONCONTINUOUS LOAD 0100% = 1363 SIGN 22 .44 CONTINUOUS LOAD: 2,400VA x 1.25 = 3,000VA 3:0 TOTAL CONNECTED LOAD: 457.7 TOTAL DEMAND LOAD: 525.2 COMPUTED SERVICE DEMAND LOAD OF 525.2 VA CO 480/277V -30 -4W = 632.4 AMPS TOTAL NUMBER OF BRANCH CIRCUITS: 193 TOTAL NUMBER OF SPARE CIRCUITS: 40 NOTE IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT LILT. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. 10 10 10 10 FILE Permit No Piar^ review approval is subect to errors and or sior . Approval of construction documents does not authorize the violation of any adopted code or ordinance. flint of approved Field Copy and conditions is acknowledged: By Date: - ° 5/ �.. ,.�. City of Tukwila BUILDING DIVISION public Works, Building Division PERMIT NUMBER 0 8 2 8 Appra / ale REVISION N0:1 ELO822B FILE COPY THE ELECTRICAL CONTRACTOR SHALL VERIFY DOSING CONDf IONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATNE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVED APR 16 200$ PERMIT CENTER US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES SEP 0 3 2009 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield. Ohio 44286 (330) 659 -6685 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 ADDENDUM A A 03/19/08 ADDENDUM B Project No. 43328 Scale AS NOTED DravnBy: JDM Y: \2008\2008- 0049 \Cad\Mep\2008-- 0049E0 -Zdwg Drawing No. PANEL SCHEDULES & NOTES E0.2 TBA Dwg Name: 2008- 0049E0 -3.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:26 pm Plotted Monday April 14, 2008 1:26pm by gsimon ONE -LINE DIAGRAM NOTES 1. THE ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER COMPANY REQUIREMENTS PRIOR TO BIDDING & INCLUDE THE COST OF ALL ASSOCIATED LABOR, MATERIALS, & CHARGES IN HIS BID. 2. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE AVAILABLE FAULT CURRENT WITH THE UTILITY COMPANY PRIOR TO BIDDING AND PROVIDE EQUIPMENT RATED ACCORDINGLY. SUBMIT FAULT CURRENT CALCULATIONS WITH SHOP DRAWING SUBMITTAL 3. ALL BUSSING SHAD_ BE COPPER. 4. PROVIDE FULL LENGTH VERTICAL BUSSING IN ALL SWITCHBOARDS, DISTRIBUTION PANELS, & PANELBOARDS. 5. PROVIDE FULL SIZE HORIZONTAL BUSSING IN ALL SWITCHBOARDS. 6. ALL CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE 7. ALL WALL - MOUNTED EQUIPMENT SHALL BE MOUNTED ON 3/4" FIRE RATED BACKBOARD. 8. ALL FLOOR- MOUNTED EQUIPMENT SHALL BE MOUNTED ON 4" HIGH CONCRETE HOUSEKEEPING PAD. 9. PROVIDE NAMEPLATES PER NAMEPLATE DETAIL 10. COORDINATE SPACE WITH ALL OTHER TRADES TO MAINTAIN ALL CODE - REQUIRED CLEARANCES. 11. REFER TO ELECTRICAL SPECIFICATIONS FOR ADDf11ONAL REQUIREMENTS. 12. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FINAL SETTINGS REQUIRED FOR ALL ADJUSTABLE /ELECTRONIC TYPE CIRCUIT BREAKERS WITH LONGTIME, SHORT TIME, GF, INSTANTANEOUS, ETC. THE ELECTRICAL CONTRACTOR SHALL PROVIDE FINAL COORDINATION STUDY. 13. THE ELECTRICAL CONTRACTOR SHALL COMPLY WITH NEC ARTICLE 110.16 FOR LABELING OF PANELS FOR ARC FLASH HAZARD WARNING AS WELL AS FOLLOWING REQUIRED SAFETY PRECAUTIONS WHEN SERVICING OR MAINTAINING ELECTRICAL EQUIPMENT. CHECK REQ'D CLEARANCE BY XFMR MANUFACTURER (6" MIN.) 1/213 HILTI KWIK BOLT 3 EMBEDDED 3 -1/2" (1 0 EA CORNER OF UNIT = 4 TOTAL) d- 3/4" CHAMFER (TYP) TRANSFORMER CURRENT LIMITING BREAKER SCHEDULE PANEL LP1- BREAKERS (wTP-1o15 PANEL 1 OF 6) g BKR DESCRIPTION - REf,E NED f®ke CODE CCV) NEC . Clay �f Tukwlla E 1LDING DM DN 1 3.OA TRACK LIGHTING 3 3.OA TRACK LIGHTING 5 3.0A TRACK LIGHTING 7 3.OA TRACK LIGHTING 9 3.OA TRACK LIGHTING 11 3.OA TRACK LIGHTING 13 3.OA TRACK LIGHTING 15 3.OA TRACK LIGHTING 17 3.OA TRACK LIGHTING 19 0.5A TRACK LIGHTING 21 0.5A TRACK LIGHTING 23 0.5A TRACK LIGHTING 25 3.OA TRACK LIGHTING 27 3.OA TRACK UGHTING 29 3.OA TRACK LIGHTING CHANNEL AND CONNECTION TO TRANSFORMER BY TRANSFORMER MANUFACTURER 6x6- W2.9xW2.9 W.W.F. / / / / / / / / /// 4 4" FROM EDGE TYP ROUGHEN SLAB & APPLY ARMATEC 110 BONDING AGENT #3 DOWELS W/ STD. HOOK DRILL & ANCHOR © 3' -0" O.C. MAX WITH ONE 0 EACH CORNER (MIN). INTO (E) SLAB USING HILTI RE500 24" MIN EMBED. (1 0 EA CORNER OF UNIT = 4 TOTAL) TRANSFORMER RESTRAINT DETAIL 1/8" = 1' -Q" LANDLORDS ELECTRIC ROOM (1ST FL, A CURRENT LIMITING BREAKER SCHEDULE PANEL LP1- BREAKERS (wTP-1o15 PANEL 2 OF 6) ar BKR DESCRIPTION - REf,E NED f®ke CODE CCV) NEC . Clay �f Tukwlla E 1LDING DM DN 2 3.0A TRACK UGHTING 4 3.0A TRACK LIGHTING 6 3.0A TRACK LIGHTING 8 3.0A TRACK LIGHTING 10 3.0A TRACK LIGHTING 12 3.OA TRACK LIGHTING 14 3.0A TRACK LIGHTING 16 3.0A TRACK LIGHTING 18 3.0A TRACK LIGHTING 20 0.5A TRACK LIGHTING 22 0.5A TRACK LIGHTING 24 0.5A TRACK LIGHTING 26 3.0A TRACK LIGHTING 28 3.0A TRACK LIGHTING 30 3.OA TRACK LIGHTING NOTES: 1. ROUTE ALL TRACK UGHTING CIRCUITS FROM BREAKER PANEL LP1 TO BREAKER WTP -1015 PANEL, LANDING EACH TRACK CIRCUIT ON THE INPUT SIDE OF THE SUPPLEMENTARY "BREAKER ". 2. WIRE FROM THE OUTPUT SIDE OF EACH SUPPLEMENTARY "BREAKER" TO THE TRACK. 3. PROVIDE QUANTITY OF DOUGLAS TRAK PAK WTP -1015 BREAKERS/ PANELS TO ACCOMMODATE ALL TRACK LIGHTING CIRCUITS. 4. BREAKERS SHALL LIMIT TRACK LOAD TO 15 WATTS MAXIMUM PER UNEAL FOOT. 5. BREAKERS FED FROM CORRESPONDING CIRCUIT NUMBER IN PANEL INDICATED. AHEAD OF TRANSFORMER NEUTRAL CONDUCTOR(S) THE NEUTRAL CONDUCTOR SHALL NOT BE BONDED TO GROUND AT METER PAN AND /OR TENANT'S ELECTRICAL DISTRIBUTION EQUIPMENT. THE GROUND FAULT PROTECTION IN LANDLORD'S DISTRIBUTION SYSTEM WILL NOT FUNCTION PROPERLY IF THE NEUTRAL IS BONDED TO GROUND. DISTRIBUTION EQUIPMENT SHALL BE SUBMITTED FOR APPROVAL TO THE ENGINEER WITH A COPY TO OWNER PRIOR TO SUBMISSION OF ORDER TO EQUIPMENT SUPPLIER. PROVIDE OWNER WITH PROOF OF PURCHASE AFTER SHOP DRAWINGS HAVE BEEN APPROVED. SHOP DRAWINGS TO BE SUBMITTED IN A TIMELY MANNER SO AS NOT TO IMPEDE JOB SCHEDULE. CURRENT LIMITING BREAKER SCHEDULE PANEL LP1- BREAKERS (wTP-1o15 PANEL 3 OF 6) E. BKR DESCRIPTION - REf,E NED f®ke CODE CCV) NEC . Clay �f Tukwlla E 1LDING DM DN 31 3.OA TRACK LIGHTING 33 3.0A TRACK LIGHTING 35 3.OA TRACK UGHTING 37 3.OA TRACK LIGHTING 39 3.OA TRACK LIGHTING 41 3.OA TRACK UGHIING 43 3.OA TRACK LIGHTING 45 3.OA TRACK LIGHTING 47 3.OA TRACK LIGHTING 49 3.OA TRACK LIGHTING 51 3.OA TRACK LIGHTING 53 3.OA TRACK UGHTING 55 3.OA TRACK LIGHTING 57 3.OA TRACK LIGHTING 59 3.OA TRACK UGHIING CURRENT LIMITING BREAKER SCHEDULE PANEL LP1-BREAKERS (wTP-1o15 PANEL 5 OF 6) roo. BKR DESCRIPTION - REf,E NED f®ke CODE CCV) NEC . Clay �f Tukwlla E 1LDING DM DN 61 3.OA TRACK LIGHTING 63 3.OA TRACK LIGHTING 65 3.OA TRACK LIGHTING 67 3.0A TRACK LIGHTING 69 3.OA TRACK LIGHTING 71 3.OA TRACK UGI-TIlNG 73 3.OA TRACK LIGHTING 75 3.OA TRACK UGHTING 77 3.0A TRACK UGHTING 79 2.OA SHOW WINDOW TRACK LTG 81 2.OA SHOW WINDOW TRACK LTG 83 2.0A SHOW WINDOW TRACK LTG 56 3.0A TRACK LIGHTING 58 3.OA TRACK LIGHTING 60 3.0A TRACK LIGHTING H &M ELECTRIC ROOM (2ND FL) CURRENT LIMITING BREAKER SCHEDULE PANEL LP1- BREAKERS (wTP-1o15 PANEL 4 OF 6) cra BKR DESCRIPTION - REf,E NED f®ke CODE CCV) NEC . Clay �f Tukwlla E 1LDING DM DN 32 3.OA TRACK LIGHTING 34 3.0A TRACK LIGHTING 36 3.0A TRACK LIGHTING 38 3.0A TRACK LIGHTING 40 3.0A TRACK LIGHTING 42 3.0A TRACK UGHTING 44 3.0A TRACK LIGHTING 46 3.OA TRACK LIGHTING 48 3.0A TRACK LIGHTING 50 3.OA TRACK LIGHTING 52 3.0A TRACK UGHTING 54 3.OA TRACK LIGHTING 56 3.0A TRACK LIGHTING 58 3.OA TRACK LIGHTING 60 3.0A TRACK LIGHTING CURRENT LIMITING BREAKER SCHEDULE PANEL LP1- BREAKERS (wTP-1o15 PANEL 7 OF 6) SQUARE D BKR DESCRIPTION - REf,E NED f®ke CODE CCV) NEC . Clay �f Tukwlla E 1LDING DM DN 62 3.0A TRACK UGHTING 64 3.0A TRACK LIGHTING 66 3.OA TRACK LIGHTING 68 3.OA TRACK LIGHTING 70 3.0A TRACK LIGHTING 72 3.0A TRACK LIGHTING 74 3.OA TRACK LIGHTING 76 3.0A TRACK LIGHTING 78 3.0A TRACK LIGHTING 80 2.0A SHOW WINDOW TRACK LTG 82 2.0A SHOW WINDOW TRACK LTG 84 2.0A SHOW WINDOW TRACK LTG VAV -2 -9 70A /3P C.B. 70A /3P C.B. - _ - 100A /1P BUSSED SPACE BUSSED SPACE EXISTING (4) SETS OF 2- 1/2 "C. W/ (4) #250kCMIL & (1) #3/0 (GND) AL BY LANDLORD FROM 'SWBD 1C' TO 800A DISC SW IN TENANT SPACE. E.C. SHALL RELOCATE EXISTING DISC SW TO NEW H &M ELEC ROOM. EC. SHALL AND EXTEND CONDUITS AND WIRE AS REQUIRED FROM EXISTING DISCONNECT SWITCH LOCATION VIA A NEW PULL BOX TO THE RELOCATED DISCONNECT SWITCH AND THEN FROM THE RELOCATED DISC SWITCH TO H &M'S MDP ( APPROX. TOTAL RUN BY H &M EC. = 250'). LANDLORD SWITCH BOARD "SWBD 1C' 480Y/277V -30 -4W 2500k SECTION 1 AIC = 30,880A PULL BOX SIZED PER NEC BY EC. TO RELOCATE EXIST. FUSED DISC. SW. TO H &M'S ELEC. ROOM (4) SETS OF 2- 1/2'C. W/ (4) #250kCMIL & (1) #3/0 (GND) AL NEW 800A /3P 480V METER BY LL 1 NEW 800A /3P FUSED SWITCH WITH (3)800A FUSES BY LL. E.C. SHALL PROVIDE NAMEPLATE PER LANLORD'S REQUIREMENTS FOR H &M DISC. SW. 800A/3P W/ (3)800A FUSES EC. MUST VERIFY DISTANCE PRIOR TO BID - 325' -0" EXISTING DISC SWITCH BY LL 800A /3P W/ (3)800AF. AIC = 26,340A _J IEC. SHALL FIELD VERIFY EXACT LOCATION OF EXISTING DISC. SW. PRIOR TO BID. SWITCH SHALL BE USED FOR ORARY POWER. DISTRIBUTION PANEL "MOP" 480Y/277V -30 -4W 800A. M.C.B. LAIC = 17,678A 411, 1 #8(G) 1- 1 /2'C. APPROX RUN = 10' A A PANEL HP1 800A /3P M.C.B. SQUARE D 225A/3P C.B. 100A /3P C.B. TRANSF. T -1 PANEL HP1 90A /3P C.B. 125A/3P C.B. ELEVATOR TRANSF. T -2 25A/1 P C.B. 25A/1 P C.B. IWH -A IWH -A 25A/1 P C.B. 50A/1 P C.B. IWH -A IWH -B 35A/1 P C.B. 40A/113 C.B. VAV -1 -1 VAV -1 -2 25A/3P C.B. 60A /3P C.B. VAV -2 -1 VAV -2 -5 35A/1 P C.B. 45A/1 P C.B. VAV -1 -3 VAV -2 -2 50A/1 P C.B. 45A/1 P C.B. VAV -2 -3 VAV -2 -4 20A/1P C.B. 20A/1P C.B. VAV -2 -6 VAV -2 -7 10A/1 P C.B. 35A/1P C.B. VAV -2-8 VAV -2 -9 70A /3P C.B. 70A /3P C.B. ESCALATOR 1 ESCALATOR 1 100A /3P 100A /1P BUSSED SPACE BUSSED SPACE 411, 1 #8(G) 1- 1 /2'C. APPROX RUN = 10' A A PANEL HP1 277/480V -30 -4W SQUARE D POWERUNK G3 'MASTER' PANEL AIC = 16,256A 125A. M.LO. 18 CIRCUIT CONTROL BUS A 3#4/0 & 1#4 GND IN 2-1/2°C APPROX RUN = 10' TRANSFORMER 1T -2" IS STACKED ABOVE TRANSFORMER "T -1 ". E.C. SHALL PROVIDE STRUCTURE TO MOUNT TRANSFORMERS PER DETAILS ON E4.3. 3#1/0 & 1 #6 GND IN 2'C APPROX RUN Q O 75KVA TRANSFORMER 480V -30 -3W PRIMARY 208Y/120V -30 -4W SECONDARY PRIMARY AIC = 16,498A SECONDARY AIC = 5,870A T -2 150.OKVA TRANSFORMER 480V -30 -3W PRIMARY 208Y/120V -30 -4W SECONDARY A PRIMARY AIC = 16,960A SECONDARY AIC = 10,246A #2 GND PER NEC TO ALL AVAILABLE GROUNDING ELECTRODES. T -1 DOUGLAS TRAK PAK SUB- BRANCH CIRCUIT CURRENT LIMITER WITH INTEGRAL BREAKERS TO SERVE THE LOADS OF THE TRACK PANELS. (TYP. OF 6) THE TOP BREAKER IN THIS PANEL SHALL BE LOCATED AT A MAXIMIUM HEIGHT OF 6' -O" FROM THE FLOOR. (TYP. OF 2) SQUARE D POWERUNK G3 "SLAVE" PANEL PANEL LP1 120/208V-30-4W _ AIC = 9,739A SECTION 1 A AIC SECTION _ = 9,739A 2 /1 400A. M C.B. / 21 CIRCUI -J CONTROL BUS #250kCMIL GND PER NEC TO ALL AVAILABLE GROUNDING ELECTRODES. A 21 CIRCUIT CONTROL BUS • 41600kCMIL & 1#3(G)-3 1/2.c. APPROX RUN A WTP -1015 CURRENT LIMITED SUPPLEMENTARY BREAKERS FOR PANEL TOTAL OF (15) BREAKERS WTP -1015 CURRENT LIMITED SUPPLEMENTARY BREAKERS FOR PANELS TOTAL OF (15) BREAKERS WTP -1015 CURRENT UMIfED SUPPLEMENTARY BREAKERS FOR PANELS TOTAL OF (12) BREAKERS (3) SPACES 4j1,1 i & 8(G) APPROX RUN A S WTP -1015 CURRENT LIMITED SUPPLEMENTARY FOR PANEL 1 TOTAL OF (15) BREAKERS WTP -1015 CURRENT LIMITED SUPPLEMENTARY BREAKERS FOR PANELS TOTAL OF (15) BREAKERS WTP -1015 CURRENT LIMITED SUPPLEMENTARY BREAKERS FOR PANELS TOTAL OF (12) BREAKERS 4 #1CO3 & 1 #4(G) -2 APPROX RUN A PANEL 1P3 120/208V -30 -4W 18 CIRCUIT CONTROL BUS AIC = 5,571A 100A. M.C.B. PANEL LP2 120/208V -30 -4W AIC = 5,086A A 150A. M.C.B. 15KVA DRY TYPE ISOLATION TRANSFORMER 208V -30 -3W PRIMARY 208Y/120V -30 -4W SECONDARY PRIMARY AIC = 4,818A SECONDARY AIC = 1,077 HUNG FROM STRUCTURE.. :Av.hREFER A \ SHEET E4.3TO . DETAILS ON #8 GND PER NEC TO ALL AVAILABLE GROUNDING ELECTRODES. 1110(G) -1 -1 /4 "C. APPROX RUN n PANEL UGA SHALL HAVE A 200% NEUTRAL BAR 314 &1 #1 /0(N) & 118 GND & 1 #8(IG) -1 1/2 "C. APPROX RUN Q ' PANEL "L1GA" 120/208V -30 -4W AIC = 1,065A l' A INSUL/ISO GND BAR 60A M.C.B. SURGE SUPPRESION SYSTEM - INTERMATIC #PG60- 208 -3Y, WITH A PANEL EXTENSION TYPE SURFACE MOUNTED ENCLOSURE. WIRE PER MANUFACTURER'S REQUIREMENTS. 2nd FLOOR 1ST FLOOR I 4" HIGH CONCRETE PAD ONE LINE DIAGRAM NO SCALE NOTE: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT EJLT, OR IBM FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDUONS TO INSURE THAT THE NEW WORK WILL FII TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDUONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVE) APR 16 2008 PERMIT CENTEh US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA WASHINGTON 98188 r� E;�r'rn_S EXPIRES SEP 0 3 2009 ■ ■ ■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield, Ohio 44286 (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 A 03/19/08 ADDENDUM A ADDENDUM B Project No. 43328 Scale AS NOTED Droopily: JDM Y: \2008 \2008- 0049 \Cad \Mep \2008- 0049E0- -3.dwg Droving No. TRAK PAK PANEL SCHEDULES AND ONE -LINE DIAGRAM E0.3 TBA Dwg Name: 2008- 0049E0 -4.dwg Scale: 1' =V -0" Dote: Apr. 14, 2008 Time: 1:26 pm Platted Monday April 14, 2008 1:26pm by gsimon SEE NOTE 14 QUANTTIY AS SHOWN ON PLANS 2 - #14 & 1 -18 TWISTED SHIELDED PAIR LCD REMOTE ANNUNCIATOR PANEL 2 PHONE LINES TO MAIN TELEPHONE BOARD 6-114 - DIGITAL COMMUNICATOR $- FIRE ALARM CONTROL PANEL SD ; SEE NOTE #11 WIRE HORN /STROBES & STROBES SEPARATELY FOR SYNCHRONOUS OPERATION El -2- CONDUCTOR #14 AWG #18 AWG TWISTED SHIELDED PAIR TO ADDITIONAL DEVICES. PROVIDE EO.L RESISTOR AT END OF CIRCUIT. (TYPICAL) • TO ADDmONAL DEVICES. 120VAC TO 20A, 1P BREAKER. LOCK -ON {-.--F1- & MARK RED LIGA -35 ADDRESSABLE PULL STATION ADDRESSABLE SMOKE & HEAT DETECTORS rti FS VERIFY LOCATION & QUANTITY IN FIELD WITH LANDLORD'S REP. PRIOR TO ROUGH IN 2 - #14 AWG TO FAN CONTROLLER L FOR SHUTDOWN SEE NOTE 15 ZAM M 4 - #16 AWG c-2 - #16 AWG !MFSDI- MOTORIZED FlRE /SMOKE DAMPER FURNISHED AND INSTALLED BY M.C., AND WIRED BY EC. TYPICAL FIRE ALARM DEVICE WIRING DIAGRAM NTS FIRE ALARM SYSTEM NOTES: 1. THE SYSTEM DESIGN SHOWN AND DESCRIBED IN THE CONSTRUCTION DOCUMENTS REPRESENTS THE MINIMUM REQUIREMENTS OF THE BUILDING OWNER/ TENANT. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO VERIFY ALL REQUIREMENTS WITH THE LOCAL AUTHORITIES PRIOR TO BIDDING AND INCLUDE THE COST OF ALL REQUIRED ALARM SYSTEM COMPONENTS IN HIS BID. THE COMPLETED SYSTEM MUST MEET ALL STATE AND LOCAL CODE REQUIREMENTS AND MALL OPERATIONS CRITERIA. 2. ALL WIRING SHALL BE IN CONDUIT AND SHALL BE SIZED AS PER THE NATIONAL ELECTRIC CODE. DO NOT RUN ANY OTHER WIRING IN THE SAME CONDUIT WITH ALARM WIRING. DO NOT RUN 120VAC WIRING WITH ALARM WIRING. USE OF NON- METALIC CONDUIT REQUIRES #12 DRAIN WIRE TO MAINTAIN CONTINUITY OF SYSTEM GROUNDS AND ALL OTHER WIRE SHIELDED CABLE. 3. ALL WIRE AND CABLE MUST BE RATED PER THE LATEST REVISION OF THE NATIONAL ELECTRIC CODE SECTION 760. 4. WIRING SHOWN ON THIS DIAGRAM REPRESENTS THE MINIMUM SIZE REQUIRED. WIRE SIZES SHALL BE INCREASED AS REQUIRED FOR VOLTAGE DROP. 5. THIS DIAGRAM IS NOT INTENDED TO SHOW QUANTITIES OF DEVICES. 6. ALL CONDUCTORS INCLUDING SHIELDS MUST TEST FREE OF OPENS, SHORTS AND GROUNDS BEFORE MAKING CONNECTIONS TO THE SUPERVISORY ALARM CONTROL PANEL 7. 120 VAC POWER TO CONTROL PANEL REQUIRES A DEDICATED CIRCUIT. RUN 3 #12 (INCLUDES THE GREEN GROUND WIRE) TO 120VAC 60HZ USING 20 AMP CIRCUIT BREAKER. PROVIDE A LOCK -ON CLIP AND RED MARKING ON THE BREAKER. 8. SMOKE DETECTOR HEADS MUST BE INSTALLED FREE OF DUST OR ANY OTHER CONTAMINATION. 9. ALL DEVICES TO BE FIELD TESTED WITH WRITTEN CERTIFICATION OF SYSTEM. PERFORM ALL I1SIS IN THE PRESENCE OF THE AUTHORITY HAVING JURISDICTION. 10. PROVIDE CONNECTION TO REMOTE SUPERVISION AS DIRECTED FOR SUPERVISION OF SYSTEM IN COMPLIANCE WITH LOCAL AUTHORITY AND OWNER. PROVIDE ALL INTERFACE REQUIRED TO INTIATE REMOTE SUPERVISION. 11. PROVIDE AND INSTALL A CEILING MOUNTED SMOKE DETECTOR IN FRONT OF THE FIRE ALARM PANEL IN ADDmON TO THE DEVICES SHOWN ON THE FLOOR PLANS. 12, PROVIDE AND INSTALL MANUAL STATIONS WHERE REQUIRED BY LOCAL AUTHORITIES TO MEET THE REQUIREMENTS OF NFPA -72 SECTION 3 -8.1.2 IN ADDITION TO THE DEVICES SHOWN ON THE PLANS. VERIFY WITH LOCAL AUTHORITY PRIOR TO BIDDING AND INDICATE COST IN BID PRICE. 13. THE ELECTRICAL CONTRACTOR SHALL SUBMIT FIRE ALARM SYSTEM DRAWINGS AND SPECIFICATIONS TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND APPROVAL BEFORE ROUGH -IN OF FIRE ALARM SYSTEM DEVICES AND EQUIPMENT. 14. PROVIDE 6114 & CONDUIT FROM FIRE ALARM CONTROL PANEL TO LANDLORD'S FIRE ALARM JUNCTION BOX IN THE MALL'S CORRIDOR (VERIFY LOCATION W/ LL) FOR MONITORING OF STATUS, TROUBLE AND ALARM CONDITIONS. ADDITIONAL DEVICES, FINAL CONNECTIONS AND PROGRAMMING TO BE MADE BY LANLORD'S FIRE ALARM CONTRACTOR AT H &M'S EXPENSE. 15. MONITOR MODULE FOR MONITORING OF ALARM CONDITION BY LANDLORDS CENTRAL ARE ALARM SYSTEM TO SIGNAL SHUT DOWN OF HVAC UNITS UPON A LIFE SAFETY OCCURRENCE IN THE TENANTS LIFE SAFETY ZONE. FIRE ALARM SYSTEM THE FIRE ALARM SYSTEM SHALL BE FURNISHED, INSTALLED, PROGRAMMED AND FINAL TIE-1141-0 THE LANDLORD'S FIRE ALARM SYSTEM SHALL BE BY THE LANDLORD'S REQUIRED FIRE ALARM SUBCONTRACTOR GUARDIAN SECURITY. CONTACT: BOB VEZZANI, PONY MAURICE GUARDIAN SECURITY 9435 PROVOST ROAD NW SILVERDALE, WA 98383 PH: 360 -692 -3738 FAX: 360 -692 -6857 EMAIL bvezzaniOguardiansecurity.com, pmauriceOguardiansecurity.com FIRE ALARM SYSTEM SPECIFICATIONS SD EQUIPMENT E ROOM SD E GROUND FLOOR NOTE COORDINATE FIRE ALARM SYSTEM INSTALLATION WITH LANDLORD FOR "REQUIRED FIRE ALARM CONTRACTOR" FOR FINAL CONNECTION TO LANDLORDS CENTRAL FIRE ALARM SYSTEM. 1. EQUIPMENT: ALL DEVICES, COMBINATIONS OF DEVICES, APPLIANCES AND EQUIPMENT SHALL BE LISTED FOR THE PURPOSE FOR WHICH THEY ARE USED AND SHALL BE INSTALLED IN COMPLIANCE WITH APPLICABLE CODES AND STANDARDS. SD E SECOND FLOOR 2. PROVIDE A COMPLETE, SUPERVISED, POWER - LIMITED, ADDRESSABLE FIRE ALARM SYSTEM SYSTEM TO MATCH EXISTING LANDLORD FIRE ALARM SYSTEM. 3. THE FIRE ALARM SYSTEM SHALL BE AN ELECTRICALLY SUPERVISED SYSTEM, WHICH SHALL MONITOR THE INTEGRITY OF CIRCUIT CONDUCTORS AND POWER SUPPLIES. 4. THE INSTALLATION ORGANIZATION SHALL BE A COMPANY SPECIALIZING IN THE INSTALLATION OF FIRE ALARM SYSTEMS. THIS ORGANIZATION SHALL HAVE A MINIMUM OF FIVE YEARS EXPERIENCE WITH INSTALLATION OF SUCH SYSTEMS. 5. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ON THE SITE AN UP -TO -DATE RECORD SET OF APPROVED SHOP DRAWINGS. 6. RECORD DRAWINGS SHALL INCLUDE LOCATION OF END -OF -LINE DEVICE LOCATIONS. 7. UPON COMPLETION OF THE WORK, AND FINAL ACCEPTANCE BY THE LOCAL AUTHORITY, THE CONTRACTOR SHALL SUBMIT RECORD DRAWINGS TO THE OWNER. 8. A REMOTE MONITORING FACILITY OUTPUT CIRCUIT, SELECTABLE FOR INTERFACE TO REMOTE STATION REVERSE POLARITY, LOCAL ENERGY MASTER BOX, SHUNT MASTER BOX, DIGITAL ALARM COMMUNICATOR, OR RADIO TRANSMITTER MONITORING SYSTEMS, SHALL BE PROVIDED. THE EQUIPMENT SUPPLIER MUST CONTACT THE LOCAL AUTHORITIES PRIOR TO BIDDING AND SUPPLY ALL REQUIRED EQUIPMENT IN BASE BID. 9. CONTROL PANEL SHALL BE CAPABLE OF MONITORING ALL FIRE ALARM DEVICES INDICATED IN WIRING DIAGRAM AND SHOWN ON THE CONSTRUCTION DOCUMENTS. THE POWER SUPPLY SHALL BE ADEQUATE TO SERVE CONTROL PANEL MODULES. RELAYS AND ALARM INDICATING APPLIANCES. INCLUDE A SECONDARY EMERGENCY POWER SUPPLY WITH CAPACITY FOR OPERATING SYSTEM IN STAND -BY MODE FOR 24 HOURS FOLLOWED BY ALARM MODE FOR 10 MINUTES. THE CONTROL PANEL SHALL BE CAPABLE OF MONITORING EACH FLOOR AS A SEPERATE ZONE. ALL ZONES SHALL BE CLEARLY IDENTIFIED ON THE FAC.P. 10. ADDRESSABLE P LL TYPE NS SHALL BE SEMI - FLUSH, ACTION PUSH /PULL 11. SMOKE DETECTORS SHALL BE ANALOG PHOTOELECTRIC TYPE PROVIDE WITH AUXILIARY RELAY FOR ELEVATOR RECALL WHERE INDICATED WITH A SUBSCRIPT 'E'. 12. DUCT - MOUNTED SMOKE DETECTORS SHALL HAVE A BASE WITH AUXILIARY RELAY, ANALOG PHOTOELECTRIC DETECTOR, SAMPLING TUBES (LENGTH AS REQUIRED) AND DUCT DETECTOR REMOTE KEY RESET/TEST STATION WITH ALARM LED. 13. SEMI -FLUSH AUDIO/VISUAL UNIT SHALL BE WITH ADA COMPLYING CANDLA SERIES WITH ADA COMPLYING MULTI- CANDLA STROBE AND SPEAKER. ALL STROBE LIGHTS SHALL BE SYNCHRONIZED. 14. VISUAL ONLY UNIT ADA COMPLYING MINIMUM 75- CANDELA STROBE. ALL STROBE LIGHTS SHALL BE SYNCHRONIZED. 15. PROVIDE AND INSTALL WIRING PER MANUFACTURERS' SPECIFICATIONS. ALL WIRING SHALL BE IN CONDUIT (3/4' MINIMUM). 16. THE COMPLETED FIRE ALARM SYSTEM SHALL BE FULLY TESTED IN ACCORDANCE WITH NFPA -72H, AND LOCAL FIRE DEPARTMENT REQUIREMENTS, BY THE INSTALLER, IN THE PRESENCE OF THE OWNER'S REPRESENTATIVE AND THE LOCAL FIRE MARSHALL UPON COMPLETION OF A SUCCESSFUL TEST, THE INSTALLER SHALL SO CERTIFY, IN WRmNG, TO THE OWNER AND GENERAL CONTRACTOR. 17. INCLUDE ON -SITE SERVICES OF A CERTIFIED TECHNICIAN TO PROVIDE TECHNICAL INSTALLATION SUPPORT FOR PANEL START UP, PROGRAM EDmNG, TROUBLESHOOTING OF THE FIRE ALARM SYSTEM CONTROL PANEL, AND ASSISTANCE TO THE INSTALLER FOR ONE COMPLETE FINAL SYSTEM CHECKOUT IN ACCORDANCE WITH THE FIELD QUALITY CONTROL SECTION OF THESE SPECIFICATIONS. 18. FIRE ALARM CONTRACTOR SHALL PROVIDE SHOP DRAWINGS TO THE PROPER AUTHORITIES IN THIS JURISDICTION. THESE SHOP DRAWINGS SHALL INCLUDE, BUT NOT LIMITED TO; BATTERY CALCULATIONS, VOLTAGE DROP CALCULATIONS, MANUFACTURER /MODEL NUMBER /LISTING INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS. FIRE ALARM SYSTEM SYMBOL LEGEND SYMBOL DESCRIPTION ® CEILING- MOUNTED SMOKE DETECTOR E FIRE ALARM HORN /STROBE DEVICE ('C' DENOTES CEILING MOUNTED) El ARE ALARM VISUAL DEVICE SPRINKLER SYSTEM FLOW SWITCH BY FPC WIRED BY E.C. COORDINATE WITH MECHANICAL CONTRACTOR. SPRINKLER SYSTEM TAMPER SWITCH BY FPC WIRED BY E.C. COORDINATE WITH MECHANICAL CONTRACTOR. l; FIRE ALARM CONTROL PANEL ADDRESSABLE MONITORING MODULE RELAY . M MANUAL PULL STATION MOUNTED 48' AFF TO TOP. F LANDLORD JUNCTION BOX TIE -IN J FIRE ALARM ANNUNCIATOR J - DUCT -TYPE SMOKE DETECTOR WITH REMOTE TEST STATION PROVIDED BY ALARM SYSTEM CONTRACTOR, WIRED BY EC. - INSTALLED IN DUCTWORK BY MECHANICAL CONTRACTOR PER CODE. COORDINATE EXACT LOCATION WITH HVAC CONTRACTOR & MANUFACTURER. PROVIDE CONDUIT & WIRING NECESSARY TO SHUT DOWN HVAC UNIT UPON SMOKE DETECTOR ACTIVATION. DUCT CONNECTING ROD ELECTRICAL FlRESTAT WITH HIGH TEMPERATURE SENSOR FIE( CONDUIT AIRFLOW DUCT SMOKE DETECTOR BY EC. OPERATOR/ ACTUATOR IS-JOINT - \ SLEEVE TO `DUCT REMOTE WALL I k5I STATION BY EC. WALL CAULKING MATERIAL DAMPER FRAME OVERCENTER LOCK SLEEVE MOUNTING ANGLES NOTE: ALL WIRING BY EC. COORDINATE INSTALLATION WITH M.C. MOTORIZED FIRE /SMOKE DAMPER DETAIL " w' NTS; FRONT VIEW A 1. GYPSUM WALL ASSEMBLY (UL /ULC CLASSIFIED U300 OR U400 SERIES) (1 -HR. OR 2 -HR. ARE-RATING) (2 -HR. SHOWN). 2. (NOT SHOWN). WOOD STUDS TO CONSIST OF NOMINAL 2' x 4' LUMBER. STEEL STUDS TO BE MINIMUM 2 -1/2' WIDE. 3. PENETRATING ITEM TO BE ONE OF THE FOLLOWING : A MAXIMUM 30' DIAMETER STEEL PIPE (SCHEDULE 10 OR HEAVIER). B. MAXIMUM 30" DIAMETER CAST IRON PIPE. C. MAXIMUM 6' NOMINAL DIAMETER COPPER PIPE. D. MAXIMUM 6" NOMINAL DIAMETER STEEL CONDUIT. E. MAXIMUM 4' NOMINAL DIAMETER EMT. 4. HILT] FS -ONE HIGH PERFORMANCE INTUMESCENT FIRESTOP SEALANT : A. MINIMUM 5/8 ", FOR A 1 -HR. FIRE - RATING. B. MINIMUM 1 -1/4" DEPTH, FOR A 2 -HR. TIRE -- RATING. 5. MINIMUM 1/2' BEAD HILT] FS -ONE HIGH PERFORMANCE INTUMESCENT FlRESTOP SEALANT AT POINT OF CONTACT. NOTES : 1. MAXIMUM DIAMETER OF OPENING : A. 32 -1/4' FOR STEEL STUD WALLS. B. 14.1/2' FOR WOOD STUD WALLS. 2. ANNULAR SPACE = MINIMUM 0 ", MAXIMUM 2 -1/2'. METAL PIPE THROUGH 1 -HR. OR 2 -HR. GYPSUM WALL ASSEMBLY NTS F- RATING = 1 -HR. OR 2 -HR. T- RATING = 0 -HR. L- RA11NG AT AMBIENT = LESS THAN 1 CFM /SQ. FT. L- RATING AT 400'F = 4 CFM /SQ. FT. UL /cUL SYSTEM NO. W -L -1054 RECEIVED APR 16 2008 PERMIT CENTER US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EX`P RES 1 EXPIRES SEP 0 3 2009 ■ �_ ■ ■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetshoro Road (330) 659 -6688 Ph. Richfield. Ohio 44286 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/19/08 ADDENDUM B Project No. Scale DrownBy: 43328 AS NOIEU JDM Y: \2008 \2008-0049 \Cad \Mep \2008- 0049E0 -4.dwg Drawing No. FIRE ALARM SYSTEM, NOTES AND DETAILS E0.4 E 1 CI E t= a a N t; 0 0 a 7 v G N TEA Dwg Name: 2008- 0049E2 -1.dwg Plotted Tuesday March 18, 2008 2:13pm by ataylor FIXTURE TYPE "EM2" (TYPICAL) ADJACENT TENANT N.I.C. (E) ELEVATOR N.I.C. 20 NALL CONCOURSE N.I.C. MO 2'4 ENTRANCE HP1 -1- (TIE) FIXTURE TYPE '0' (TYPICAL of 2) LINE OF (E) PEDESTRIAN BRIDGE ABOVE FIXTURE TYPE 'P' (TYPICAL U.O.N.) ESCALATOR N.LC. FIXTURE TYPE 'G' STORAGE FIXTURE TYPE "A" (TYPICAL) FIXTURE TYPE 'C' (TYPICAL) DASHED LINE INDICATES EXTENT OF ESCALATOR ABOVE P1 -6 156 SF RE TYPE 'E1' ICAL) ADJACENT TENANT N.I.C. co REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 I) 2008 City Of Tukwila BUILDIN DIVISION GROUND FLOOR GENERAL LIGHTING PLAN 1 /8" = 1' -0" IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. GENERAL LIGHTING NOTES 1. REFER TO DRAWING E4.1 FOR SCHEDULES AND DETAILS OF THE LIGHTING CIRCUITS CONTROLLED BY THE SQUARE D "POWERUNK' LIGHTING CONTROL SYSTEM. 2. ONLY 'NORMAL" BALLAST OF TYPE 'C" FIXTURES SHALL BE CONTROLLED VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE 'C" EMERGENCY BALLASTS, EMERGENCY LIGHTS AND BUT SIGN BATTERIES IN THE SALES AREA SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE REQUIRED "POWERUNK" EMERGENCY LIGHTING CIRCUIT BREAKER(S). REFER TO PANEL SCHEDULES ON DWG. E0.2. 3. ONLY THE 'NORMAL' BALLASTS OF TYPE 'H' FIXTURES LOCATED IN THE BACK —OF —HOUSE SHALL BE CONTROLLED VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE 'H' EMERGENCY BALLASTS, AND EXIT SIGN BATTERIES IN THE BACK —OF— HOUSE SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE SQUARE —D "POWERUNK" EMERGENCY LIGHTING CIRCUIT BREAKER (S). REFER TO PANEL SCHEDULES ON DRAWING E0.2 4. ALL NIGHT LIGHTS (NL) SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE SQUARE —D 'POWERLINK' EMERGENCY LIGHTING CIRCUIT BREAKER (S). 5. SHADED SALES LIGHTNG AND HALF—SHADED NON —SALES LIGHTING FIXTURES SHALL BE PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDJONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 ( EXPIRES 9. 3 - 1 ■�_ ■■ THORSON BAKER 3030 West Streetsboro Road Richfield, Ohio 44286 & Associates, Inc. Consulting Engineers (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date 02/06/08 03/07/08 .\ 03/18/08 Issue DESIGN DEVELOPMENT PERMIT, LANDLORD, BID ADDENDUM A RECE:.. f+ITV yr T{ Atni • yr* gn I °IHK 1 5 LUU PERMIT CENTER Project No. Scale DrarnBy: 43328 1/8" = 1' -0" JDM f Y:\2008\2008- 0049 \Cad\Mep \Recardsat\ADDENDUM A \2008-0049E2 -1.d Drawing No. GROUND LEVEL GENERAL LIGHTING PLAN E2.1 US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 FIXTURE TYPE (TYPICAL) FIXTURE TYPE "B2' ADJACENT TENANT N.I.C. EXPRES `S- 3- o l MAR 2 5 2008 ■.r■rr■e�e���r. RXTU TYPE 'D21 OF -) City Of Tukwila BUILDING DIVISION ■■ THORSON BAKER & Associates, Inc. Consulting Engineers (330) 659 -6688 Ph. (330) 659 -6675 Fax 3030 West Streetsboro Road Richfield. Ohio 44286 ® , KO HP1 -13 GENERAL LIGHTING NOTES 1. REFER TO DRAWING E4.1 FOR SCHEDULES AND DETAILS OF THE LIGHTING CIRCUITS CONTROLLED BY THE SQUARE D 'POWERIJNK" LIGHTING CONTROL SYSTEM. 2. ONLY "NORMAL" BALLAST OF TYPE "C" FIXTURES SHALL BE CONTROLLED VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE "C' EMERGENCY BALLASTS, EMERGENCY LIGHTS AND EXIT SIGN BATTERIES IN THE SALES AREA SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE REQUIRED "POWERLINK' EMERGENCY LIGHTING CIRCUIT BREAKER(S). REFER TO PANEL SCHEDULES ON DWG. E0.2. 3. ONLY THE 'NORMAL" BALLASTS OF TYPE 'H" FIXTURES LOCATED IN THE BACK —OF —HOUSE SHALL BE CONTROLLED VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE 'H' EMERGENCY BALLASTS, AND EXIT SIGN BATTERIES IN THE BACK —OF— HOUSE SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE SQUARE —D 'POWERLINK' EMERGENCY LIGHTING CIRCUIT BREAKER (S). REFER TO PANEL SCHEDULES ON DRAWING E0.2 4. ALL NIGHT LIGHTS (NL) SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE SQUARE —D "POWERLINK' EMERGENCY LIGHTING CIRCUIT BREAKER (5). QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 ADDENDUM A 5. SHADED SALES LIGHTNG AND HALF— SHADED NON —SALES LIGHTING FIXTURES SHALL BE PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. HP1 -20122 HP1 -5, HP1 -8,10 HP1 -15,17 IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. R�.� L_.h �� C;I1Yur iLin,= MAR 19 ZUUU TBA Dwg Name: 2008- 0049E2- 2a.dwg Scale: f =1' —D" Date: Mar. 18, 2008 Time: 2:14 pm ALL WIRING SHALL BE IN CONDUIT E.I.T. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. PERMIT CENTER ■ 41► 41110 110 411 ■∎�.� �� �� ■�10 1� �01 ► �, HP1 -12 MALL SERVICE CORRIDOR 1 HP1 -14,16 HP1 -9,11 N.1.C. ►►�►.�1 ►11►1 ►1 ► ► ►�► ■ ■1►.�wIl�l∎ Platted Tuesday March 18, 2008 2:14pm by ataylor FIXTURE TYPE (TYPICAL) HP1 -24,26 HP1-19,21 THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDMONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATNE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. Project No. Scale DravnBy: 43328 1/8" = 1' -0" JDM Y: \2008\ 2008 -0049Vad\MeARecordSet\ADDHNDUM A \2008- 0049E24 SECOND LEVEL A GENERAL LIGHTING PLAN 1/8- = 1' -0" Droving No. SECOND LEVEL A GENERAL LIGHTING PLAN E2.2A TBA Dwg Name: 2008- 0049E2- 2b.dwg Scale: 1' =1' -0" Date: Apr. 14. 2008 lime: 1:26 pm Plotted Monday April 14, 2008 1:25pm by gsimon ENT aNT C. FIXTURE TYPE 'S" (TYPICAL OF 3) FIXTURE TYPE (TYPICAL OF 2) HEN'S TOILET ROOM MALL CONCIURSE N.I.C. ADJACENT T N.I.C. WON EN'S TOILET R00 v JANITOR CLOSET NANT1 IFIXTURE TYPE "H' (TYPICAL U.O.N.) LOUNGE 29.9 MALL SERVICE CORRIDOR N.I.C. AM--"En1 ■ten ■I■■■■■■■GII■ 1■ ■1 ' ∎— �■■■■ ■■■■ r r 111 ■ ■I r■% ■■ ■■ ■■ ■ •■ 1■ ■ I I�■l��w�■_�■■ ■■ II,rr ■17I ` ■■■ I •• ■ •■ 1■ ■ 1� M I1 1 r i I F II [■■ ! Ilur/ ■ �\ .11111�■ii ■I _u I��� [■1■ ■■ ■ ■■r ■■ J■■«i ■ ■■■ air ► -i- ■III E1- gI I ■1 ! ��`�■.••__ ___• 1/■ ■� 1►r ■■ ■■ i !!!!!itI! `i ■iri■ �s ■Wi■ r 1.►7�1i■■ ■��/ II ■III ,,„��1� ■t ■�� illiiiii I MEW ►f 111111 ��% pk I 1■E1■ �E 1 ■!IUII1 E� ■A!!!I►l immmwimmin imaglomilaimomme. 1' _� ■1 I■ ■■ ■_ ■11P' mitifiL i' .��I� 1II 1 ■I I' ' ±' _y�■11■ ■� w1 a 1■■ ■••1LV 11 1 VIALL SERVICE CORRIDOR N.I.C. PROCESSING w r 14] DECO ROOV1 ELECTRICAL /LAN ADvIN /SECURITY MANAGER SECOND LEVEL B GENERAL LIGHTING PLAN 1/8- = 1' -O° 0 G.9 0 NOTES IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBIUTY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. m O GENERAL LIGHTING NOTES 1. REFER TO DRAWING E4.1 FOR SCHEDULES AND DETAILS OF THE LIGHTING CIRCUITS CONTROLLED BY THE SQUARE D 'POWERLJNK' LIGHTING CONTROL SYSTEM. 2. ONLY 'NORMAL' BALLAST OF TYPE 'C' FIXTURES SHALL BE CONTROLLED VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE "C' EMERGENCY BALLASTS, EMERGENCY LIGHTS AND EXIT SIGN BATTERIES IN THE SALES AREA SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE REQUIRED 'POWERUNK' EMERGENCY LIGHTING CIRCUIT BREAKER(S). REFER TO PANEL SCHEDULES ON DWG. E0.2. 3. ONLY THE 'NORMAL' BALLASTS OF TYPE "H" & "S" FIXTURES LOCATED IN THE BACK —OF —HOUSE SHALL BE CONTROLLED VIA THE LIGHTING CONTROL SYSTEM. ALL TYPE "H" & 'S' EMERGENCY BALLASTS, AND EXIT SIGN BATTERIES IN THE BACK —OF— HOUSE SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE SQUARE —D "POWERLINK" EMERGENCY LIGHTING CIRCUIT BREAKER (S). REFER TO PANEL SCHEDULES ON DRAWING E0.2 4. ALL NIGHT LIGHTS (NL) SHALL BE WIRED TO THE NON — CONTROLLED HALF OF THE SQUARE —D 'POWERLINK" EMERGENCY LIGHTING CIRCUIT BREAKER (S). 5. SHADED SALES UGHTNG AND HALF— SHADED NON —SALES UGHIING FIXTURES SHALL BE PROVIDED WITH AN INTEGRAL EMERGENCY BALLAST. ALL WIRING SHALL BE IN CONDUIT E.I.L OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDMONS TO INSURE THAT THE NEW WORK WILL FTT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDFONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATNE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVED APR 16 2008 PERMIT CENTER US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 [EXPIRES EXPIRES SEP 0 3 2009 8 ■ ■ ■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6668 Ph. Richfield. Ohio 44286 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID Q 03/18/08 ® 03/19/08 ADDENDUM A ADDENDUM B Project No. 43328 MIN Scale 1/8" = 1' -0" DravnBy: JDM Y: \2008 \2009- 9049 \Cad \Mep \2008- 0049E2- 21).dwg Droving No. SECOND LEVEL B GENERAL LIGHTING PLAN E2.2B Dote: Apr. 14, 2008 Time: 1:25 pm TBA Dwg Name: 2008- 0049E3 -1.dwg Scale: Plotted Monday April 14, 2008 1:25pm by gsimon iv LICA -2,4 LIGA -18,20 11 HOLIDAY CASHWRAP LP2 -16 LIGA -18 0 3(D) $- or 16 LP2 -16 '2 -16 IG. UGA-20 4(D) 1!.. 00 IG. LIGA -22 LP2 -16 IC 11 4D (TYP. AT CASHWRAP) HOLIDAY CASHWRAP PARTIAL CASHWRAP PLAN A LP (D SENSORMATIC DIMENSIONS ARE APPROXIMATE WO $FlAttO 13,ECOEIR5E FOR PRICING PURPOS REFER TO MANUFACTURPRIV1JTERATURE FOR LAYOUT AND ACTUAL DIMENSIONS. ENT NCE LP2 -17 (11E) LINE OF (E) PEDESTRIAN BRIDGE ABOVE —17 r J I UGA-15 LP3 -8 SALES AREA 5,215 SF 0 UP MDP -9 6.5 KW 1/3 M.P. 277V, 10 ADJACENT TENANT N.I.C. APPROXIMATE LOCATION OF EXISTING ELECTRIC SERVICE CONDUIT AND TELEPHONE CONDUIT STUB —IN. E.C. SHALL PROVIDE THE ELECTRIC SERVICE WIRE & EXTEND CONDUITS AS REQUIRED TO PANEL 'MDP'. EXTEND TELEPHONE CONDUIT AS REQUIRED AND PULL NEW WIRE FROM LL TELEPHONE CLOSET TO H &M'S PHONE BOARD. L///4, a (0 CEILING) F. (E) ESCALATOR N.I.C. STORAGE 156 SF DASHED LINE INDICATES EXTENT OF ESCALATOR ABOVE ADJACENT TENANT N.I.C. O PLUMBING CODED NOTES D.E = DUAL ELEMENT TYPE FUSE P1 PROVIDE A NEMA 1, 208V, 30A/3P FUSIBLE DISCONNECT SWITCH WITH (3) 6.25A D.E. FUSES AT THE UNIT. PROVIDE 4112, 1112(G) -3/4' C. FROM A 15A/3P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE ELEVATOR SUMP PUMP. CODED NOTES 0 MOUNT RECEPTACLE HORIZONTAL AT 6' A.F.F. COORDINATE LOCATION IN BASE OF COLUMN WITH MIRROR INSTALLATION. INSTALL ON NON— MIRRORED SURFACE, VERIFY LOCATION WFFH H &M PROJECT MANAGER. ® REFER TO TYPICAL CASH WRAP ELEVATION ON DWG. E4.1 AND ENLARGED PLAN THIS SHEET. DOORBELL SYSTEM. REFER TO WIRING DIAGRAM ON DWG. E4.1. • DUPLEX OUTLET FLUSH MOUNTED IN CEILING AT DISPLAY WINDOW. • PROVIDE J —BOX ABOVE CEILING AT BACK DOOR FOR FUTURE SECURITY OR SENSORMAT1C EQUIPMENT. EC. SHALL HARD WIRE ALL EQUIPMENT AND DEVICES. © ACCESS PANEL IN CEILING FOR ACCESS TO ELECTRICAL EQUIPMENT. COORDINATE WITH G.C. FOR THE FURNISHING AND INSTALLING OF ACCESS PANEL BY G.C. O7 DUPLEX RECEPTACLE IN FLUSH FLOOR BOX IN RAISED PLATFORM. SEE SPECIFICATIONS FOR MANUFACTURER AND CATALOG NUMBERS. SEE ARCHITECTURAL DRAWINGS FOR INSTALLATION DETAILS. ® SENSORMATIC FULLY CONCEALED DIGITAL FLOORMAX ANTENNAS. ROUTE (2) 3/4" RIGID CONDUIT WITH PULLSTRING IN THE FLOOR TO A FULL HEIGHT WALL AND STUB INTO AN ACCESSIBLE CEILING SPACE FOR FUTURE SENSORMATIC CABLES (BY SENSORMATIC), TYPICAL THE EC. SHALL COORDINATE WITH H &M AND SENSORMATIC FOR EXACT LOCATIONS AND REQUIREMENTS FOR SENSORMATIC EQUIPMENT ROUGH —IN. ® J —BOX MOUNTED ABOVE THE CEILING FOR POWER TO FUTURE SENSORMATIC EQUIPMENT. COORDINATE CONNECTION WITH SENSORMATIC REPRESENTATIVE. 10 FURNISH AND INSTALL A 20A. SPST TOGGLE SWITCH FOR SIGNAGE POWER ABOVE THE CEILING. COORDINATE WITH H &M FOR THE LOCATION, MOUNTING HEIGHT AND QUANTITY OF SIGN(S) AND FURNISH AND INSTALL ALL POWER, CONDUIT, WIRING, INTERCONNECTIONS, ETC., AS REQUIRED. PROVIDE CONTROL OF SIGNAGE AS INDICATED ELSEWHERE ON CONSTRUCTION DOCUMENTS. A 11 A 14 1(D) SM 6.5 KW 1/3 H.P 277V, 1 3/4 H.P. ESP 208V, 30 1 LP2- 23,25,27 CONTRACTOR SHALL INSTALL IG RECEPTACLE AND TEL /DATA DEVICE CLOSEST TO REGISTER PORTION OF THE CASH DESK (TYPICAL OF ALL CASH REGISTERS). COORDINATE FINAL LOCATION WITH ARCHITECT PRIOR TO COMMENCEMENT. 12 MOUNT RECEPTACLE IN FITTING ROOM CORRIDOR AT 12" A.F.F. 13 DEDICATED CIRCUIT(S) FOR HOLIDAY ROLL—AWAY CASHWRAPS. EC. SHALL INSTALL RECEPTACLES FOR ALL ROLL—AWAY CASHWRAPS. RECEPTACLES TO BE LOACTED AT CONVENIENT LOCATION FOR ADDITIONAL CASHWRAPS. VERIFY LOCATION WITH H &M REPRESENTATIVE 14 ONE CAT 5E DATA PORT 6' BELOW FINISHED CEILING FOR WIRELESS ACCESS NODE. IF INSTALLED NEAR FLOATING CEILING, NODE SHALL BE INSTALLED 6" BELOW FLOATING CEILING. VERIFY EXACT LOCATION WITH OWNER. 15 DATA OUTLET WITH (2) TWO CAT 5E CABLES ABOVE ACCESS PANEL IN CEILING FOR FUTURE TRAFFIC COUNTING DEVICE. 16 PROVIDE CONDUIT WITH PULL WIRE FROM CASHWRAP BACK TO 2ND FLOOR LAN ROOM FOR DATA CABLE REFER TO CONDUIT FILL REQUIREMENTS CHARTS FOR CONDUIT SIZE ON DWG E5.3. COORDINATE EXACT REQUIREMENT WITH G.C. AND ARCHITECT. 17 EC SHALL RECONNECT ALL ELECTRICAL DEVICES AND EQUIPMENT LOCATED IN THE ELEVATOR MACHINE ROOM AND ELEVEVATOR PIT TO PANEL LP2 AS REQUIRED. THE EC SHALL RECONNECT THE EXISTING ELEVATOR MOTOR DISCONNECT 10 PANEL MDP AS REQUIRED. IF ANY ELECTRICAL DEVICES OR DISCONNECTS SHOWN OR CALLED OUT FOR IN THIS SET OF DRAWINGS ARE NOT INSTALLED, THE EC SHALL FURNISH AND INSTALL AS REQUIRED PER NEC. HVAC CODED NOTES D.E. = DUAL ELEMENT TYPE FUSE 0 PROVIDE A NEMA 1, 480V, 60A /1P FUSIBLE DISCONNECT SWITCH WITH (1) 40A D.E. FUSE AT THE UNIT. PROVIDE 2ff8, 1 #10(0) -3/4' FROM A 40A/1 P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. 0 PROVIDE A NEMA 1, 480V, 60A /1P FUSIBLE DISCONNECT SWITCH WITH (1) 35A D.E FUSE AT THE UNIT. PROVIDE 218, 1I10(G) -3/4" C. FROM A 35A/1 P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. TTT iii LU MALL SERVICE CORIDOR N.I.C. (E) ELEVATOR APPROXIMATE LOCATION OF EXIT I N.I.C. EXISTING LANDLORD FIRE ALARM J —BOX FOR TENANT TIE —IN. (FIELD VERIFY) GROUND FLOOR POWER PLAN 1/8- = NT IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. NOTE: ALL CONCRETE SLAB PENETRATIONS MUST BE COORDINATED WITH CENTRAL MANAGEMENT. CORE DRILLING, SAW CUTTING, JACK HAMMERING, BUSH HAMMERING, CHIPPING, ETC., ARE NOT PERMITTED WITHOUT PRIOR APPROVAL THE GENERAL CONTRACTOR MUST PERFORM A FIELD SURVEY OF THE AREA BELOW ANY PROPOSED FLOOR PENETRATIONS TO VERIFY THE EXISTENCE OF ANY ELECTRICAL, MECHANICAL, ETC., EQUIPMENT. IN ADDITION TO ABOVE, FLOOR PENETRATIONS ARE TO BE HYDRAULICALLY I SEALED AND A WATERPROOF MEMBRANE SHALL BE USED. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDMONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVED APR 16 2008 PERMIT CENTE- US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 I EXP }RES EXPIRES SEP 0 3 2009 ■ ,� ■ ■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield. Ohio 4-4286 (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 ADDENDUM A L 03/19/08 ADDENDUM B Project No. 43328 Scale 1/8" = MEW DravnBy: JDM Y:\ 2008 \2008- 0049 \Cad \Mep \2008-0049E3--1.dwg Droving No. GROUND LEVEL POWER PLAN E3.1 TBA Dwg Name: 2008- 0049E3- 2a.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:25 pm Plotted Monday April 14, 2008 1:25pm by gsimon A 0 o „b l .gi 0 0 0 0 0 &-,t, 0 UGA -24,26 LP2 -18,20 LIGA -28 � PARTIAL CASHWRAP PLAN 1/4" = 1' -0" 2 -21 SENSORMATIC DIMENSIONS ARE APPROXIMATE AND SHALL BE USED FOR PRICING PURPOSES ONLY. REFER TO MANUFACTURER'S LITERATURE FOR LAYOUT AND ACTUAL DIMENSIONS. 11► ADJACENT TENANT N.I.C. UGA -34 HOLIDAY CASHWRAP 9.0 KW HI 1/3 H.P. 277V, 10 CODED NOTES 1d JUNCTION BOX FURNISHED WITH MIRROR LOCATED AT TOP OF MIRROR ASSEMBLY (TYPICAL). VERIFY MIRROR LOCATIONS WITH ARCHITECTURAL PLANS PRIOR TO ROUGH -IN. 2® DATA OUTLET WITH (2) TWO CAT 5E CABLE ABOVE ACCESS PANEL IN CEILING FOR FUTURE TRAFFIC COUNTING DEVICE. ® MOUNT RECEPTACLE HORIZONTAL AT r A.F.F. COORDINATE LOCATION IN BASE OF COLUMN WITH MIRROR INSTALLATION. INSTALL ON NON - MIRRORED SURFACE, VERIFY LOCATION Wm-i H &M PROJECT MANAGER. ® DOORBELL SYSTEM. REFER TO WIRING DIAGRAM ON DWG. E4.1. K E.C. SHALL RUN CONDUIT ALONG TOP OF FITTING ROOM PARTITION TO WALL, AND THEN IN WALL FROM MIRROR JUNC. BOX TO MIRROR JUNC. BOX. CONDUIT SHALL BE RUN CONTINUOUS FROM MIRROR TO MIRROR WITHOUT INTERRUPTION BETWEEN MIRRORS (TYPICAL). ® © RErt_H TO TYPICAL CASH WRAP ELEVATION ON DWG. E4.1 AND ENLARGED PLAN THIS SHEET. ✓ MOUNT RECEPTACLE IN FITTING ROOM CORRIDOR AT 12" A.F.F. ® DUPLEX OUTLET FLUSH MOUNTED IN CEILING AT DISPLAY WINDOW. ® DEDICATED CIRCUIT(S) FOR HOLIDAY ROLL -AWAY CASHWRAPS. EC. SHALL INSTALL RECEPTACLES FOR ALL ROLL -AWAY CASHWRAPS. RECEPTACLES TO BE LOACTED AT CONVENIENT LOCATION FOR ADDITIONAL CASHWRAPS. VERIFY LOCATION WITH H &M REPRESENTATIVE AND COORDINATE WITH WALL FIXTURES. ® ACCESS PANEL IN CEIUNG FOR ACCESS TO ELECTRICAL EQUIPMENT. COORDINATE WITH G.C. FOR THE FURNISHING AND INSTAWNG OF ACCESS PANEL BY G.C. 11 DUPLEX RECEPTACLE IN FLUSH FLOOR BOX IN RAISED PLATFORM. SEE SPECIFICATIONS FOR MANUFACTURER AND CATALOG NUMBERS. SEE ARCHITECTURAL DRAWINGS FOR INSTALLATION DETAILS. ® 12 SENSORMATIC FULLY CONCEALED DIGITAL FLOORMAX ANIDINAS. ROUTE (2) 3/4" RIGID CONDUIT WITH PULLSTRING IN THE FLOOR TO A FULL HEIGHT WALL AND STUB INTO AN ACCESSIBLE CEILING SPACE FOR FUTURE SENSORMATIC CABLES (BY SENSORMATIC), TYPICAL THE EC. SHALL.. COORDINATE WITH H &M AND SENSORMATIC FOR EXACT LOCATIONS AND REQUIREMENTS FOR SENSORMATIC EQUIPMENT ROUGH -IN. 13 J -BOX MOUNTED ABOVE THE CEILING FOR POWER TO FUTURE SENSORMATIC EQUIPMENT. COORDINATE CONNECTION WITH SENSORMATIC REPRESENTATIVE. MDP -15 SALES AREA MDP -16 SALES AREA CONTRACTOR SHALL INSTALL IG RECEPTACLE AND TEL /DATA DEVICE CLOSEST TO REGISTER PORTION OF THE CASH DESK (TYPICAL OF ALL CASH REGISTERS). COORDINATE FINAL LOCATION WITH ARCHITECT PRIOR TO COMMENCEMENT. 15 FURNISH AND INSTALL A 20A. SPST TOGGLE SWITCH FOR SIGNAGE AND BLADE SIGNAGE POWER ABOVE THE CEIUNG. COORDINATE WITH H &M FOR THE LOCATION, MOUNTING HEIGHT AND QUANTITY OF SIGN(S) AND FURNISH AND INSTALL ALL POWER, CONDUIT, WIRING, INTERCONNECTIONS, ETC., AS REQUIRED. PROVIDE CONTROL OF SIGNAGE AS INDICATED ELSEWHERE ON CONSTRUCTION DOCUMENTS. (=> PROVIDE A RECESSED JUNCTION BOX WITH A UQUIDTIGHT FLEXIBLE METAWC CONDUIT WHIP FROM THE JUNCTION BOX TO THE TYPE "L" STRIP FIXTURES MOUNTED IN THE WALL POP OUT COVE. COORDINATE THE JUNCTION BOX LOCATION IN THE FIELD. JUNCTION BOX SHALL BE LOCATED BEHIND THE POP OUT WALL, HIDDEN FROM VIEW. SEE BELOW FOR FIXTURE COUNTS AT POP OUT WALLS. REFER TO ARCHITECTURAL PLANS FOR STAGGERED FIXTURE PLACEMENT WITHIN THE WALL POP OUT COVE. ALL WIRING SHALL BE CONCEALED. MDP -13 MDP -14 HOLIDAY CASHWRAP LP3 -5 (TIE) WAIL 2 9.0 KW 1/3 H.P. 277V, 10 ` - -�� LP3 -5 WALL 1 16 IMOMOMIIIMIMM.110- 41111.- A010- ADMIIMIK71 3.0 KW 1/6 H.P. 277V, 10 1/2 H 208V, MDP -12 MDP -18 ra EL 2- MDP-17 3.0 KW 1/6 H.P. 277V, 10 0 Yil�1 1 1 1 11x1 to- ► ► Apo- ■ ►AID■ ■t ► ■ ■ ■ ►A►� ►� ►� ►���►� ►�E�:\ LP2 -33,35 (TYPICAL FOR FITTING ROOMS) (TYPICAL FOR FITTING ROOMS MALL SERVICE CORRIDOR N.I.C. N ALL CONCRETE SLAB PENETRATIONS MUST BE COORDINATED WITH CENTRAL MANAGEMENT. CORE DRIWNG, SAW CUTTING, JACK HAMMERING, BUSH HAMMERING, CHIPPING, ETC., ARE NOT PERMITTED WITHOUT PRIOR APPROVAL THE GENERAL CONTRACTOR MUST PERFORM A FIELD SURVEY OF THE AREA BELOW ANY PROPOSED FLOOR PENETRATIONS TO VERIFY THE EXISTENCE OF ANY ELECTRICAL, MECHANICAL, ETC., EQUIPMENT. IN ADDITION TO ABOVE, FLOOR PENETRATIONS ARE TO BE HYDRAULICALLY SEALED AND A WATERPROOF MEMBRANE SHALL BE USED. SECOND LEVEL A POWER PLAN, EB1 1 /8" = NOTE: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. WALL 1. 13 - 26' -9' LENGTH: (6) TYPE L4, (1) TYPE L3 TOP AND BOTTOM WALL 2. 3. 4. 5. 6. 7. 10. 14 - 10' -4" LENGTH: (2) TYPE L4, (1) TYPE 1.2 TOP AND BOTTOM WALL 8. 12 - 14' --6' LENGTH: (3) TYPE L4, (1) TYPE 1.2 TOP AND BOTTOM WALL 9 - 6' -2' LENGTH: (1) TYPE L4, (1) TYPE 1.2 TOP AND BOTTOM WALL 11 - 33'-1" LENGTH: (8) TYPE L4, (1) TYPE L2 TOP AND BOTTOM DATA OUTLET WITH (1) ONE CAT 5E CABLE 6* BELOW CEILING FOR WIRELESS NETWORK NODE. PROVIDE CONDUIT WITH PULL WIRE FROM CASHWRAP BACK TO 2ND FLOOR LAN ROOM FOR DATA CABLE. REFER TO CONDUIT FILL REQUIREMENTS CHARTS FOR CONDUIT SIZE ON DWG E5.3. COORDINATE EXACT REQUIREMENT WITH G.C. AND ARCHITECT. 19 EC SHALL RECONNECT ALL ELECTRICAL DEVICES AND EQUIPMENT LOCATED IN THE ELEVATOR MACHINE ROOM AND ELEVEVATOR PfT TO PANEL LP2 AS REQUIRED. THE EC SHALL RECONNECT THE EXISTING ELEVATOR MOTOR DISCONNECT TO PANEL MDP AS REQUIRED. IF ANY ELECTRICAL DEVICES OR DISCONNECTS SHOWN OR CALLED OUT FOR IN THIS SET OF DRAWINGS ARE NOT INSTALLED, THE EC SHALL FURNISH AND INSTALL AS REQUIRED PER NEC. HVAC CODED NOTES D.E. = DUAL ELEMENT TYPE FUSE H1 PROVIDE A NEMA 1, 208V, MOTOR RATED SWITCH AT THE UN PROVIDE 3112, 1112(G) -3/4" C. FROM A 15A/2P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE SWITCH FOR EF- PROVIDE A NEMA 1, 480V, 60A /3P FUSIBLE DISCONNECT SWIT H WITH (3) 60A D.E FUSES AT THE UNIT. PROVIDE 44, 1 #10(G -1 1/4" C. THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. W Of TUIWilla FROM A 60A/3P CIRCUIT BREAKER AT THE PANEL INDICATED T C c&DTPA 7D - NEC iVF 0 PROVIDE A NEMA 1, 277V, MOTOR RATED SWITCH AT THE UNIT. PROVIDE 2112, 1112(G) -3/4" C. FROM A 20A/1 P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE SWITCH FOR THE FAN POWERED VAV UNIT. . D YON ILDIN H4 PROVIDE A NEMA 1, 480V, 30A/3P FUSIBLE DISCONNECT SWITCH WITH (3) 25A D.E. FUSES AT THE UNIT. PROVIDE 410, 1I10(G) -3/4' C. FROM A 25A/3P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. 0 PROVIDE A NEMA 1, 480V, 60A /1P FUSIBLE DISCONNECT SWITCH WITH (1) 45A D.E. FUSE AT THE UNIT. PROVIDE 216, 1110(G) -3/4" C. FROM A 45A/1P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. H6 PROVIDE A NEMA 1, 480V, 60A/1P FUSIBLE DISCONNECT SWITCH WITH (1) 50A D.E. FUSE AT THE UNIT. PROVIDE 216, 1110(G) -3/4' C. FROM A 50A/1P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDIT1ONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANTS REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVED APR 16 20 PERMIT CENTER I1�- US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 j EXPIRES 1 EXPIRES SEP 0 3 2009 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield, Ohio 44286 (330 ) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID 03/19/08 ADDENDUM B Project No. 43328 Scale MIN 1/8" = 1' -0" DravnBy: JDM Y:\2008\2CK18--0049Vad\MeA2008-0049E3-20.dwg Droving No. SECOND LEVEL A POWER PLAN E3.2A l .gi N ALL CONCRETE SLAB PENETRATIONS MUST BE COORDINATED WITH CENTRAL MANAGEMENT. CORE DRIWNG, SAW CUTTING, JACK HAMMERING, BUSH HAMMERING, CHIPPING, ETC., ARE NOT PERMITTED WITHOUT PRIOR APPROVAL THE GENERAL CONTRACTOR MUST PERFORM A FIELD SURVEY OF THE AREA BELOW ANY PROPOSED FLOOR PENETRATIONS TO VERIFY THE EXISTENCE OF ANY ELECTRICAL, MECHANICAL, ETC., EQUIPMENT. IN ADDITION TO ABOVE, FLOOR PENETRATIONS ARE TO BE HYDRAULICALLY SEALED AND A WATERPROOF MEMBRANE SHALL BE USED. SECOND LEVEL A POWER PLAN, EB1 1 /8" = NOTE: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. WALL 1. 13 - 26' -9' LENGTH: (6) TYPE L4, (1) TYPE L3 TOP AND BOTTOM WALL 2. 3. 4. 5. 6. 7. 10. 14 - 10' -4" LENGTH: (2) TYPE L4, (1) TYPE 1.2 TOP AND BOTTOM WALL 8. 12 - 14' --6' LENGTH: (3) TYPE L4, (1) TYPE 1.2 TOP AND BOTTOM WALL 9 - 6' -2' LENGTH: (1) TYPE L4, (1) TYPE 1.2 TOP AND BOTTOM WALL 11 - 33'-1" LENGTH: (8) TYPE L4, (1) TYPE L2 TOP AND BOTTOM DATA OUTLET WITH (1) ONE CAT 5E CABLE 6* BELOW CEILING FOR WIRELESS NETWORK NODE. PROVIDE CONDUIT WITH PULL WIRE FROM CASHWRAP BACK TO 2ND FLOOR LAN ROOM FOR DATA CABLE. REFER TO CONDUIT FILL REQUIREMENTS CHARTS FOR CONDUIT SIZE ON DWG E5.3. COORDINATE EXACT REQUIREMENT WITH G.C. AND ARCHITECT. 19 EC SHALL RECONNECT ALL ELECTRICAL DEVICES AND EQUIPMENT LOCATED IN THE ELEVATOR MACHINE ROOM AND ELEVEVATOR PfT TO PANEL LP2 AS REQUIRED. THE EC SHALL RECONNECT THE EXISTING ELEVATOR MOTOR DISCONNECT TO PANEL MDP AS REQUIRED. IF ANY ELECTRICAL DEVICES OR DISCONNECTS SHOWN OR CALLED OUT FOR IN THIS SET OF DRAWINGS ARE NOT INSTALLED, THE EC SHALL FURNISH AND INSTALL AS REQUIRED PER NEC. HVAC CODED NOTES D.E. = DUAL ELEMENT TYPE FUSE H1 PROVIDE A NEMA 1, 208V, MOTOR RATED SWITCH AT THE UN PROVIDE 3112, 1112(G) -3/4" C. FROM A 15A/2P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE SWITCH FOR EF- PROVIDE A NEMA 1, 480V, 60A /3P FUSIBLE DISCONNECT SWIT H WITH (3) 60A D.E FUSES AT THE UNIT. PROVIDE 44, 1 #10(G -1 1/4" C. THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. W Of TUIWilla FROM A 60A/3P CIRCUIT BREAKER AT THE PANEL INDICATED T C c&DTPA 7D - NEC iVF 0 PROVIDE A NEMA 1, 277V, MOTOR RATED SWITCH AT THE UNIT. PROVIDE 2112, 1112(G) -3/4" C. FROM A 20A/1 P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE SWITCH FOR THE FAN POWERED VAV UNIT. . D YON ILDIN H4 PROVIDE A NEMA 1, 480V, 30A/3P FUSIBLE DISCONNECT SWITCH WITH (3) 25A D.E. FUSES AT THE UNIT. PROVIDE 410, 1I10(G) -3/4' C. FROM A 25A/3P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. 0 PROVIDE A NEMA 1, 480V, 60A /1P FUSIBLE DISCONNECT SWITCH WITH (1) 45A D.E. FUSE AT THE UNIT. PROVIDE 216, 1110(G) -3/4" C. FROM A 45A/1P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. H6 PROVIDE A NEMA 1, 480V, 60A/1P FUSIBLE DISCONNECT SWITCH WITH (1) 50A D.E. FUSE AT THE UNIT. PROVIDE 216, 1110(G) -3/4' C. FROM A 50A/1P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDIT1ONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANTS REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVED APR 16 20 PERMIT CENTER I1�- US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 j EXPIRES 1 EXPIRES SEP 0 3 2009 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield, Ohio 44286 (330 ) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID 03/19/08 ADDENDUM B Project No. 43328 Scale MIN 1/8" = 1' -0" DravnBy: JDM Y:\2008\2CK18--0049Vad\MeA2008-0049E3-20.dwg Droving No. SECOND LEVEL A POWER PLAN E3.2A Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:25 pm TBA Dwg Name: 2008- 0049E3- 2b.dwg Plotted Monday April 14, 2008 1:25pm by gslmon EN'S TOILET ROOIi WOMEN'S TOILET ROM JANITOR CLOSET LOUNGE -'I + -uU CO R VALL SERVICE CORRIDOR N «VAV' 2 -9, t- � �TT 4 a F ; :7% 6.0 KW 1/4 H.P. 277V, 1 t MDP -2 AV t5 KW 1/6 H.P. MALL SERVICE CORRIDOR N.I.C. ti 1 EF -2 BIJ BIJ 311 UW ACC ACC ACC ACC ACC ACC ACC ACC ACC ACC ACC ACC 4110. PROCESSII\ G DOH 9NVH 9NVH 9NVH I 1 le..... HANG HANG HANG / LP2 15,17 D H.P. ® \'. ELECTRICAL /LAN ADMIN /SECURITY DECO ROOM MANAGER SECOND LEVEL B HVAC POWER PLAN 1 /8" = 1' -0" 28 30 EN'S TOILET ROOM WOMEN'S TOILET ROOM JANITOR CLOSET LOUNGE MALL SERVICE N CORRIDOR LP2- 7,9,11 �:�_ � ACC �C ACC ACC ACC IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO COORDINATE LOCATION OF MANAGER'S DESK PRIOR TO ROUGH —IN OF RECEPTACLES. DATA & RECEPTACLES SHALL BE LOCATED AT DESK. (TYPICAL FOR ADMIN OFFICE AND MANAGER'S OFFICE) PROCESSING MOUNT 6 ABOVE COUNTER MALL SERVICE CORRIDOR w DECO ROOM A SECOND LEVEL B POWER PLAN 1/8" = 1' -0" ELECTRICAL /LAN ADMIN /SECURITY MANAGER NOTE: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE All BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. 0 z PARTIAL PLUMBING PLAN 4), 1/8" = PLUMBING CODED NOTES P1 IWH —A; 5.5KW, 277V -10 INSTANTANEOUS ELECTRIC WATER HEATER — PROVIDE A 30A, 277V, NEMA 1 MOTOR RATED SWITCH. ROUTE 2/10, 1/10(G)-- 3/4 "C. FROM A 25A/1P CIRCUIT BREAKER AT THE PANEL MDP TO THE SWITCH. BRANCH TO THE UNIT VIA LIQUIDIIGHT FLEXIBLE METAWC CONDUIT. COORDINATE EXACT ROUGH —IN LOCATIONS IN THE FIELD. P2 IWH —B; 11.08KW, 277V-10 INSTANTANEOUS ELECTRIC WATER HEATER — PROVIDE A 60A /2P, 480V, NEMA 1 FUSED DISCONNECT SWffCH WITH (1) 50A FUSE. ROUTE 2fl6, 1 I10(G)- 3 /4'C. FROM A 50A/1P CIRCUIT BREAKER AT THE PANEL MDP TO THE DISCONNECT SWITCH. BRANCH TO THE UNIT VIA LIQUIDTIGI-IT FLEXIBLE METALLIC CONDUIT. COORDINATE EXACT ROUGH —IN LOCATIONS IN THE FIELD. CODED NOTES U DUPLEX OUTLET AND DATA JACK FOR EMPLOYEE TIME CLOCK MOUNTED AT 48" A.F.F. O2 DOORBELL SYSTEM. REFER TO WIRING DIAGRAM ON DWG. E4.1. 3® REFER TO ENLARGED PLAN OF THIS AREA ON DWG. E4.1. ® QUAD I.G. OUTLETS AND DATA JACKS MOUNTED 36' AFF IN DECO ROOM. VERIFY EXACT LOCATION IN ROOM WITH H&M REP. ON SITE PRIOR TO ROUGH —IN. 5® CONTROL RELAY MOUNTED IN A NEMA 1 ENCLOSURE ABOVE THE CEILING FOR LIGHTING CONTROL SYSTEM TIE —IN TO TEMP. CONTROL PANEL REFER TO WIRING DIAGRAM ON DRAWING E4.1. :6 FLUSH JUNCTION BOX FOR POWER TO TEMP. CONTROL PANEL VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH M.C. 7O ELECTRIC J —BOX ABOVE CEILING FOR FUTURE EMPLOYEE CARD SWIPE. PROVIDE CONDUIT, WIRE & LOOP FOR FUTURE EMPLOYEE CARD SWIPE. HVAC CODED NOTES D.E. = DUAL ELEMENT TYPE FUSE 0 PROVIDE A NEMA 1, 208V, MOTOR RATED SWITCH AT THE UNIT. PROVIDE 3112, 1 #12(G) --3/4' C. FROM A 15A/2P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE SWITCH FOR EF -2. O. PROVIDE A NEMA 1, 480V, 60A/1 P FUSIBLE DISCONNECT SWITCH WITH (1) 3M D.E. FUSE AT THE UNIT. PROVIDE 218, 111((G) -3/4" C. FROM A 35A/1 P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE DISCONNECT SWITCH FOR THE FAN POWERED VAV UNIT. O PROVIDE A NEMA 1, 277V, MOTOR RATED SWITCH AT THE UNIT. PROVIDE 2112, 1/12(G) -3/4' C. FROM A 20A /1P CIRCUIT BREAKER AT THE PANEL INDICATED TO THE SWffCH FOR THE FAN POWERED VAV UNIT. ALL WIRING SHALL BE IN CONDUIT E.I.T. OR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. NOTE: ALL CONCRETE SLAB PENETRATIONS MUST BE COORDINATED WITH CENTRAL MANAGEMENT. CORE DRIWNG, SAW CUTTING, JACK HAMMERING, BUSH HAMMERING, CHIPPING, ETC., ARE NOT PERMITTED WITHOUT PRIOR APPROVAL THE GENERAL CONTRACTOR MUST PERFORM A FIELD SURVEY OF THE AREA BELOW ANY PROPOSED FLOOR PENETRATIONS TO VERIFY THE EXISTENCE OF ANY ELECTRICAL, MECHANICAL, ETC., EQUIPMENT. IN ADDITION TO ABOVE, FLOOR PENETRATIONS ARE TO BE HYDRAULICALLY SEALED AND A WATERPROOF MEMBRANE SHALL BE USED. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT NE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANTS REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEIVE( APR 16 2008 PERMIT UENTEf US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES SEP 0 3 2009 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 Ph. Richfield, Ohio 44286 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/19/08 ADDENDUM B Project No Scale DravnBy: 43328 1/8" = 1' -0° JDM Y:\ 2008\ 2008 - 0049 \Cad\Me•\2008- 0049E3- 2b.dwg Drawing No. SECOND LEVEL B POWER PLAN E3.2B TBA Dwg Name: 2008- 0049E3 -3.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:25 pm Plotted Monday April 14, 2008 1:25pm by gs1mon SOUND SYSTEM INSTALLATION NOTES 1. EC. SHALL PROVIDE AIL WIRE AND CONDUITS, AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. EC. MALL PROVIDE ALL STRUCTURAL MOUNTS FOR THE SPEAKERS AND J —BOXES WIf1•I PULL STRING BACK TO THE AUDI) RACK. E.C. SHALL TAG ALL WIRES AT TERMINATION POINT. 2. AT LEAST 5/8' PLYWOOD BIOCKING IS REQUIRED FOR THE AUDIO RACK. 3. EC. TO PROVIDE CONDUIT AND DOUBLE GANG BOX AT DJ /SPEAKER JACK LOCATION. 4. E.C. TO PROVIDE (6) DOUBLE GANG 20 AMP OUTLETS IN LAN ROOM BEHIND RACK FOR SOUND SYSTEM ELECTRONICS. REFER TO ENLARGED IAN ROOM PLAN ON DWG. E4.1. 5. ALL SPEAKER WIRE TO BE 18AWG PLENUM. EXCEPT THE SPEAKER JACKS 6. (6) 12OVAC, 20AMP CIRCUITS, I.G. QUAD RECEPTACLES, MOUNTED EQUAL DISTANCES (VERTICALLY) APART BEHIND AUDIO RACK. 7. G.C. IS RESPONSIBLE FOR ALL PAINTING OF SPEAKERS AND RELATED EQUIPMENT TO MATCH SURROUNDING CEILING FINISH. SOUND SYSTEM SYMBOL LEGEND MALL CONCOURSE N.I.C. LINE OF (E) PEDESTRIAN BRIDGE ABOVE FCOORT AUDIO RACK FLOOR TO AUIYCi7ACK 2ND FLOOR To Ufa RACK 2ND FLOOR STORAGE 156 SF /TO AUDIO RACK 2ND FLOOR ENT NT C DASHED LINE INDICATES EXTENT OF ESCALATOR ABOVE (E) ELEVATOR N.I.C. GROUND FLOOR AUDIO PLAN 1/8- = is—on RECEWI/Fr APR 16 2008 PERMIT CEN Tb, US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES EXPIRES SEP 0 3 2009 e■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 Ph. Richfield. Ohio 44286 (330) 659 -6673 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/19/08 ADDENDUM B Project No. 43328 Scale 1/8" - 1' -0" DrainBy: JDM Y 2008\ 2008 -0049 \Cad \Mep \2009 -0048 E3 -3.dwg Droving No. GROUND LEVEL AUDIO PLAN E3.3 M EQUIPMENT RACK — LOCATED IN LAN ROOM 11 M.= SPEAKER JACK ffia: DJ JACK (FOR USED WITH H&M DJ SYSTEM) DJ DI i+LG 120VAC, 20AMP CIRCUIT, I.G. QUAD OUTLET, VARIOUS HEIGHTS 0 SPEAKER, FURNISHED /INSTALLED BY OTHERS (P= PENDANT) FLUSH STOREFRONT SPEAKER, FURNISHED /INSTALLED BY OTHERS MALL CONCOURSE N.I.C. LINE OF (E) PEDESTRIAN BRIDGE ABOVE FCOORT AUDIO RACK FLOOR TO AUIYCi7ACK 2ND FLOOR To Ufa RACK 2ND FLOOR STORAGE 156 SF /TO AUDIO RACK 2ND FLOOR ENT NT C DASHED LINE INDICATES EXTENT OF ESCALATOR ABOVE (E) ELEVATOR N.I.C. GROUND FLOOR AUDIO PLAN 1/8- = is—on RECEWI/Fr APR 16 2008 PERMIT CEN Tb, US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES EXPIRES SEP 0 3 2009 e■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 Ph. Richfield. Ohio 44286 (330) 659 -6673 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/19/08 ADDENDUM B Project No. 43328 Scale 1/8" - 1' -0" DrainBy: JDM Y 2008\ 2008 -0049 \Cad \Mep \2009 -0048 E3 -3.dwg Droving No. GROUND LEVEL AUDIO PLAN E3.3 © EQUIPMENT RACK — LOCATED IN LAN ROOM ©spat SPEAKER JACK DJ oa K DJ JACK (FOR USED WITH H&M DJ SYSTEM) +G 12OVAC, 20AMP CIRCUFL I.G. QUAD OUTLET, VARIOUS HUGHTS SPEAKER, FUIIISHED/INSTALLED BY OTHERS (P= PENDANT) II FLUSH STOREFRONT SPEAKER, F1JRMSHE)/INSTA1L D BY OTHERS Apr. 14, 2008 Time: 1 :24 pm TBA Dwg Name: 2008- 0049E3- 4b.dwg Scale: 1' =1' -0' Plotted Monday April 14, 2008 1:24pm by gsimon SOUND SYSTEM INSTALLATION NOTES 1. E.C. SHALL PROVIDE All WIRE AND CONDUITS, AS REQUIRED BY LOCAL AUTHORITIES HAVING JURISDICTION. EC. SHALL PROVIDE ALL STRUCTURAL MOUNTS FOR THE SPEAKERS AND J —BOXES WITH PULL STRING BACK TO THE AUDIO RACK. E.C. SWV.L TAG ALL WIRES AT TERMINATION POINT. 2. AT LEAST 5/8" PLYWOOD BLOCKING IS REQUIRED FOR THE AUDIO RACK. EC. TO PROVIDE CONDUIT AND DOUBLE GANG BOX AT DJ /SPEAKER JACK LOCATION. 4. EC. TO PROVIDE (6) DOUI311 GANG 20 AMP OUTLETS IN LAN ROOM BEHIND RACK FOR SOUND SYSTEM ELECTRONICS. REFER 1D ENLARGED LAN ROOM PLAN ON DWG. E4.1. 5. ALL SPEAKER WIRE TO BE 18AWG PLENUM. EXCEPT THE SPEAKER JACKS 3. 6. (6) 120VAC, 20AMP CIRCUITS, I.G. QUAD RECEPTACLES, MOUNTED EQUAL DISTANCES (VENIICALLY) APART BEHIND AUDIO RACK. 7. G.C. IS RESPONSIBLE FOR ALL PAINTING OF SPENCERS AND RELATED EQUIPMENT TO MATCH SURROUNDING CEILING FINISH. SOUND SYSTEM SYMBOL LEGEND RACK EQUIPMENT RACK - LOCATED IN LAN ROOM .2 5ria in. SPEAKER JACK Ya DJ JACK (FOR USED WITH H&M DJ SYSTEM) DJ o.I • 120VAC, 20AMP CIRCUIT, I.G. QUAD OUTLET, VARIOUS HEIGHTS ACC SPEAKER, FURNISHED/INSTALLED BY OTHERS (PENDANT) FLUSH STOREFRONT SPEAKER, FURNISHED /INSTALLED BY OTHERS FROM SPEAIORS ., SPEAKERS FROM SPEAKERS]. FROM SPEAKERS/ FROM SPEAKERS FROM SPEAKERS/ FROM SPEAERS. FROM SPEAi(ERSI FROM SPEAKERS! FROM SPEAKERS / FROM SPEAKERS/ FROM SPEAKERS/ FROM SPEAKERS„_„ FROM SPEAKERS/ FROM SPEAKERS/ FROM SPEAKERS./ FROM SPENCERS FROM SPEAKERS/ FROM SPEAKERS/ FIiOM �� ADJACEN T TENANT N.I.C. MEN'S TOILET BOON MALL CONCIURSE N.I.C. ADJACENT T N.I.C. WO V EN'S TOILET ROM NANT1 C1 JANITOR CLOSET LOUNGE FROM DJ JACK I .1 ... • 1 Row :mew .. n.Urni -.. I. w:� • LF. 11-111w. I■.�� ■_I tl■.1■. ■111 •s; ■ ■1 MALL SERVICE CORRIDOR N.I.C. i 811 B11 811 UW ACC ACC ACC ACC ACC ACC ACC ACC ACC ACC ACC NMI EN MI Min [V ALL SERVICE CORRIDOR N.I.C. 9NVH HANG 9NVH HANG 9NVH HANG ONVH I DECO ROOM sa) PROCESSING ELECTRICAL /LAN ADMIN /SECURITY MANAGER SECOND LEVEL B AUDIO PLAN 1/8" = 1' -0" 0 0 O APR 16 Zuud PERMIT CENTEF•+ U8159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 4 EXPIRES EXPIRES SEP 0 3 2009 • THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West 5treetsboro Road Richfield. Ohio 44286 (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID ® 03/19/08 ADDENDUM B Project No. Scale DrawoBy: 43328 1/8" = 1' -0" JDM Y:\ 2008 \2008 - 0049 \Cad \Mep \2oo8- 0049E3- 46.dwg Drawing No. SECOND LEVEL B AUDIO PLAN E3.4B TBA Dwg Name: 2008- 0049E3 -5.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Plotted Monday April 14, 2008 1 :24pm by gsimon CODED NOTES O PROVIDE A JUNCTION BOX MOUNTED TO THE STRUCTURAL CEILING AND PROVIDE A 1/2 "C. WITH PULLWIRE FROM JUNC11ON BOX TO THE SECURITY PANEL FOR FUTURE SECURITY DEVICE. SECURITY DEVICES SUCH AS GLASS BREAK SENSORS AND MOTION DETECTORS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR. V PROVIDE A JUNC11ON BOX FOR SECURITY CAMERAS AND A 1/2 "C. WITH PULLWIRE FROM JUNCTION BOX TO THE SECURITY OFFICE FOR FUTURE SECURITY CAMERAS. VERIFY EXACT LOAC11ON AND QUANTITY PRIOR TO BID. C/ JUNCTION BOX AND QUAD OUTLET FOR POWER TO SECURITY PANEL. ALSO SHOWN ON SHEET E4.1. ® PROVIDE J--BOX ABOVE CEILNG AT BACK DOOR FOR FUTURE SECURITY OR SENSORMAIIC EQUIPMENT. E.C. SHALL HARD WIRE ALL EQUIPMENT AND DEVICES. ADJACENT TENANT N.I.C. (E) ELEVATOR N.I.C. NALL CONCOURSE N.I.C. ENTRANCE TO ' N UNE OF (E) PEDESTRIAN BRIDGE ABOVE SALES AREA 5,215 SF —DOWN SE -6ICE AREA 128 SF FITTING ROOK 492 SF (E) ESCALATOR N.I.C. STORAGE 1565F DASHED LINE INDICATES EXTENT OF ESCALATOR ABOVE ADJACENT TENANT N.I.C. MALL SERVICE CORIDOR N.I.C. GROUND FLOOR SECURITY PLAN 1/8" = 1' -0" RECEIVED APR 16 2006 PERMIT CENTER US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 1 EXPIRES EXPIRES SEP 0 3 2009 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6666 Ph. Richfield, Ohio 44286 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID ® 03/19/08 ADDENDUM B Project No. Scale DrawnBy: 43328 1 /8" = 1' -0" JDM Y:\ 2008\ 2008 - -0049 \Cad \Mep \2008- 0049E3 -5.dwq Drawing No. GROUND LEVEL SECURITY PLAN E3.5 IBA Dwg Name: 2008- 0049E3- 6a.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 lime: 1:24 pm Plotted Monday April 14, 2008 1:24pm by gsiman ADJACENT TENANT N.I.C. SALES AREA SALES AREA 1 411111r - / / ,. ' `. �1 i VALL SERVICE CORRIDOR N.I.C. SECOND LEVEL A SECURITY PLAN IT 1/8" = 1' -0" i 14t) CODED NOTES Ot PROVIDE A JUNCTION BOX MOUNTED TO THE STRUCTURAL CEILING AND PROVIDE A 1/2 "C. WITH PULLWIRE FROM JUNCTION BOX TO THE SECURITY PANEL FOR FUTURE SECURITY DEVICE. SECURITY DEVICES SUCH AS GLASS BREAK SENSORS AND M0110N DETECTORS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR. i PROVIDE A JUNCTION BOX FOR SECURITY CAMERAS AND A 1/2 "C. WITH PULLWIRE FROM JUNCTION BOX TO THE SECURITY OFFICE FOR FUTURE SECURITY CAMERAS. VERIFY EXACT LOAC11ON AND QUANTITY PRIOR TO BID. 0 JUNCTION BOX AND QUAD OUTLET FOR POWER TO SECURITY PANEL ALSO SHOWN ON SHEET E4.1. PROVIDE J —BOX ABOVE CEILING AT BACK DOOR FOR FUTURE SECURITY OR SENSORMATIC EQUIPMENT. EC. SHALL HARD WIRE ALL EQUIPMENT AND DEVICES. RECEIVEr APR 16 2008 PERMIT CENT& US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES EXPIRES SEP032009 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield. Ohio 44286 (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID ® 03/19/08 ADDENDUM B Project No. 43328 Scale 1/8" = 1' -O" DravnBy: JDM Y: \2008 \2008 - 0049 \Cad\MeP \2008-- 0049E3- Ba.dwg Droving No. SECOND LEVEL A SECURITY PLAN E3.6A US159 SOUTHCENTER MALL MALL CONCCURSE 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 ADJACENT TENANT N.I.C. TEXPR S CODED NOTES 01 PROVIDE A JUNCTION BOX MOUNTED TO THE STRUCTURAL CIIUNG AND PROVIDE A 1/2'C. WITH PULLWIRE FROM JUNCTION BOX TO THE SECURITY PANEL FOR FUTURE SECURITY DEVICE. SECURITY DEVICES SUCH AS GLASS BREAK SENSORS AND M0110N DETECTORS SHALL BE PROVIDED BY THE SECURITY CONTRACTOR. PROVIDE A JUNCTION BOX FOR SECURITY CAMERAS AND A 1/2'C. WITH PULLWIRE FROM JUNCTION BOX TO THE SECURITY OFFICE FOR FUTURE SECURITY CAMERAS. VERIFY EXACT LOACTION AND QUANTITY PRIOR TO BID. ADJACENT T4�A N.I.C. EXPIRES SEP 0 3 2009 THORSON BAKER 3030 West Streetsboro Road Richfield. Ohio 44286 & Associates, Inc. Consulting Engineers (330) 659-6688 Ph. (330) 659 -6675 Fax 30 JUNCTION BOX AND QUAD OUTLET FOR POWER TO SECURITY .1 PANEL ALSO SHOWN ON SHEET E4.1. a4 APPROXIMATE LOCATION OF SECURITY KEY PAD AND KEYSWITCH AT EMPLOYEE ENTRANCE VERIFY EXACT LOCATION WITH H &M REPRESENTATIVE. SEE E4.1 FOR WIRING DETAILS. :5 PROVIDE J —BOX ABOVE CEILING AT BACK DOOR FOR FUTURE SECURITY OR SENSORMATIC EQUIPMENT. E.C. SHALL HARD WIRE ALL EQUIPMENT AND DEVICES. EN'S TOILET ROOM QARC No. Date WOMEN'S TOILET ROOM JANITOR CLOSET LOUNGE Issue 02/06/08 03/07/08 DESIGN DEVELOPMENT PERMIT, LANDLORD, BID /6.\ 03/19/08 ADDENDUM B MALL SERVICE BIJ I BIJ I BIJ CORRIDOR ACC I ACC ACC ACC ACC ACC ACC ACC ACC ACC PROCESSING CORRIDOR TBA Dwg Name: 2008- 0049E3- 6b.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:23 pm Project No. 43328 MEI Plotted Monday April 14. 2008 1:23pm by gsimon VALL SERVICE CORRIDOR N.I.C. ELECTRICAL /LAN ADMIN /SECURITY MANAGER Scale 1/8" = 1' —O" Drawnfly: JDM Y:\ 2008 \2008- 0049 \Cad \Mep \2008- 0049E3- 6b.dwg DECO ROOV RECE WEr. APR 16 2008 PERMIT CENTEI- Drawing No. SECOND LEVEL B SECURITY PLAN E3.6B TBA Dwg Name: 2008- 0049E3- 8b.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 lime: 1:23 pm Plotted Monday April 14, 2008 1:23pm by gsimon GENERAL NOTES: 1. REFER TO SHEET E0.4 FOR FIRE ALARM DETAILS AND LEGENDS.. 2. COORDINATE INSTALLATION OF FIRE ALARM NOTIFICATION DEVICES WITH H &M PROJECT MANAGER AND AUTHOR[TY IN FIELD. INSTALL AS CLOSE TO EDGE OF NON — MIRRORED SIDE OF THE COLUMN AS I5 PRACTICAL FOR COLUMN MOUNTED DEVICES. 3. FIRE ALARM DEVICES WITH SUBSCRIPT 'C" SHALL BE CEILING MOUNTED. COORDINATE LOCATION WITH HVAC AND ELECTRICAL EQUIPMENT /FIXTURE LOCATIONS. ADJACENT TENANT N.I.C. EN'S TOILET ROOV MALL CONCIURSE N.I.C. ADJACENT T N.I.C. WOMEN'S TOILET ROOM JANITOR CLOSET NANH LOUNGE r .`1 MALL SERVICE CORRIDOR N.I.C. w• M =1 DECO ROOM MALL SERVICE CORRIDOR N.I.C. BIJ uw ACC ONVH ONVH 9NVH HANG HANG HANG ONVH I ACC ACC ACC PROCESS' \IG ELECTRICAL /LAN ADV IN /SECURITY MANAGER SECOND LEVEL B FIRE ALARM PLAN 1/8" = 1' -0" E.10 J.8 G.9 REVIEWEPLipNCE CODE A 70 _ NEC �,F e(Tulogila Sr BUILDING DIVISION J.8 RECEWVEr APR 16 2008 PERMIT CENTER US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 IFXPIRES EXPIRES SEP 0 3 2009 ■ ■ ■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 Ph. Richfield. Ohio 44286 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/19/08 ADDENDUM B Project No. Scale Drawn By: 43328 1/8" = 1' -O" JDM Y: \2008 \2006 -0049 \Cad \Mep \2008- 0049E3- 8b.dwg Drawing No. SECOND LEVEL B FIRE ALARM PLAN E3.8B I ACC ACC ACC ACC ACC ACC ACC ACC r< kI As ONVH ONVH 9NVH HANG HANG HANG ONVH I ACC ACC ACC PROCESS' \IG ELECTRICAL /LAN ADV IN /SECURITY MANAGER SECOND LEVEL B FIRE ALARM PLAN 1/8" = 1' -0" E.10 J.8 G.9 REVIEWEPLipNCE CODE A 70 _ NEC �,F e(Tulogila Sr BUILDING DIVISION J.8 RECEWVEr APR 16 2008 PERMIT CENTER US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 IFXPIRES EXPIRES SEP 0 3 2009 ■ ■ ■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6688 Ph. Richfield. Ohio 44286 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/19/08 ADDENDUM B Project No. Scale Drawn By: 43328 1/8" = 1' -O" JDM Y: \2008 \2006 -0049 \Cad \Mep \2008- 0049E3- 8b.dwg Drawing No. SECOND LEVEL B FIRE ALARM PLAN E3.8B TBA Dwg Name: 2008- 0049E4 -1.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:23 pm Plotted Monday April 14, 2008 1:23pm by gsiman H &M FURNISHED SAFE (1) QUAD CONVENIENCE RECEPTACLE, (1) QUAD I.G. RECEPTACLE, AND DATA JACKS MOUNTED TO BACK SIDE OF MILLWORK, LOCATED UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA /SELVES FOR BAGS (TYPICAL). HAND HOLE FOR ROLL—UP HOLIDAY CASHWRAPS. QUAD I.G. OUTLET ON DEDICATED CIRCUIT O 0 O 0 LIGA -9 N M N ACCESS (TYPICAL) H &M SERVER /CABINET FURNISHED, INSTALLED & WIRED BY H&M O 0 O 0 uGA -11 QUAD I.G. OUTLET ON DEDICATED CIRCUIT ELEVATION ff A!! CASH ROOM WALL ELEVATIONS NO SCALE GENERAL NOTES 1. VERIFY LOCATION OF H &M FURNISHED SERVER /CABINET BELOW COUNTER WFFH H &M REP. ON SITE PRIOR TO ROUGH —IN OF DEVICES BELOW COUNTER. THESE DEVICES SHALL BE INSTALLED ADJACENT TO CABINET. 2. ALL JACKS ARE ARBITRARILY LABELED AS DATA, AS DATA AND TELEPHONE USE THE SAME JACKS. THE H &M I.T. REPRESENTATIVE SHAD_ DETERMINE WHICH JACKS ARE FOR DATA AND WHICH ARE SECTION VIEW A • (1) QUAD CONVENIENCE RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. — (1) QUAD ISOLATED GROUND RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. — SECTION A -A DATA • A ii DATA DATA JACKS MOUMED VER11CALLY IN SURFACE BOX TO BACK SIDE OF MILLWORK. PROVIDE (5) DATA JACKS FOR EACH PAIR OF REGISTERS AT EACH CASHWRAP LOCATION. LOCATE DIRECTLY UNDER ACCESS COVER PLATE BELOW FOLDING AREA/SELVES FOR BAGS. SEE POWER PLANS FOR EXACT QUANTITY OF DATA JACKS REQUIRED. SYMBOL ON DWG. — v (#D) BACK VIEW CASH WRAP ELEVATION -CORE DRILL I.G. ELEVATION "B" FINISHED FLOOR FIRE RATED POKE — THROUGH FOR CASH WRAP BRANCH CIRCUIT ISOLATED GROUND POWER WIRING. PROVIDE (1) HUBBELL PT7XC WITH 2 —GANG PEDESTAL SERVICE FITTING FR8OAL AND FURNITURE FEED OPENING SS309SF. USE 1 -1/4' STEM FOR POWER WIRING. BRANCH TO DEVICES VIA UQUIDTIGHT FLEXIBLE METALLIC CONDUIT. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. — ED ROUTE NORMAL POWER WIRING VIA THE 1/211C. STEM IN THE HUBBELL FIRE RATED POKE — THROUGH. PROVIDE AN SS309SF FACE PLATE FOR NORMAL POWER. BRANCH TO DEVICES VIA LIQUIDTIGHT FLEXIBLE METAWC CONDUIT. FIRE RATED POKE — THROUGH FOR DATA WIRING FOR CASH WRAP. PROVIDE (1) HUBBELL PT7XC WITH 2 —GANG PEDESTAL SERVICE FITTING FR8OAL AND BUSHED DATA OPENING FACE PLATE SS309T. USE 1 -1/4' STEM FOR DATA WIRING. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. — NO SCALE GENERAL NOTES 1. REFER TO DRAWING E3.1 FOR QUANTITY AND LOCATIONS OF ALL POWER AND DATA DEVICES. 2. ALL JACKS ARE ARBITRARILY LABELED AS DATA, AS DATA AND TELEPHONE USE THE SAME JACKS. THE H &M I.T. REPRESENTATIVE SHALL DETERMINE WHICH JACKS ARE FOR DATA AND WHICH ARE FOR TELEPHONES. (TYPICAL) 3. ALL FLOOR CONDUIT PENETRATIONS SHALL BE FIRE RATED OR FIRE STOPPED AS REQUIRED BY THE LOCAL JURISDICTION AND /OR LANDLORD. 4. PROVIDE HUBBELL S5309B BLANK FACEPLATES FOR UNUSED PEDESTAL COMPARTMENTS. LP2 -5 120VAC -1 0 PUSHBUTTON — EDWARDS 1600 QUANTITY AS INDICATED ON PLANS. WIRE PUSHBUTTONS IN PARALLEL TRANSFORMER — EDWARDS 590 MOUNTED TO 4' SQ. BOX ON WALL IN STOCK ROOM. BUZZER(S) — EDWARDS 1661 FLUSH MOUNTED 8' -0 A.F.F. AT BACK OF HOUSE OR ON CEILING IN SALES AREA. QUANTITY AS INDICATED ON PLANS. DOORBELL WIRING DIAGRAM NO SCALE NOTE ALL LOW VOLTAGE WIRING TO BE #14AWG. 120VAC, LP3 -12 (CONTROLLED C B ZONE 1) R1 -} CONTROL RELAY: CUTLER — HAMMER jD15CR22AB MTH (2) N.O. CONTACTS AND (2) N.C. CONTACTS, MOUNTED IN A NEMA 1 ENCLOSURE ABOVE THE CASH OFFICE LAY —IN CEILING. PROVIDE A CUTLER— HAMMER 1C321 MP1 MOUNTING PLATE. ENCLOSURE SHALL BE HOFFMAN #A8N86 WITH HOFFMAN IA8N8P BACK PANEL TO I-IVAC CONTROL PANEL WIRING BY EC. COORDINATE WITH T.C. CONTRACTOR WIRING DIAGRAM - LIGHTING CONTROL TIE -IN TO HVAC CONTROLS NO SCALE T —ISO HUNG FROM STRUCTURE ABOVE PNLS ENLARGED ELECTRIC /LAN ROOM PLAN NO SCALE EC. SHALL COORDINATE ALL ELECTRICAL EQUIPMENT LOCATIONS WITH THE MECHANICAL AND PLUMBING TRADES. CODED NOTES (6) QUAD I.G. RECEPTACLES EVENLY SPACED BEHIND AUDIO RACK FOR SOUND SYSTEM POWER. K2 JUNCTION BOX AND QUAD I.G. RECEPTACLE FOR SECURITY PANEL 0 JUNCTION BOX FOR SPEAKER WIRING. 4'H.x4'W.x3 /4b. TO BOTTOM. RE TREATED PLYWOOD BOARD. MOUNT AT 24' A.F.F. DATA RACK FLOORSTANDING WITH SUFFICIENT SPACE TO OPEN FRONT AND BACK DOORS ON PLYWOOD BOARD. REFER TO SPECIFICATIONS FOR RACK REQUIREMENTS. QUAD OUTLET SHALL BE INSTALLED BY EC. IN CENTER OF THE RACK TO COORDINATE WITH RAIL LOCATIONS. EC. SHALL MODIFY RACK ACCORDINGLY TO ACCOMMODATE THE OUTLET. 1- 1/2'C. W /PULLSTRING BY H &M'S EC. FOR TELEPHONE SERVICE FROM LL CABLE TRAY TO LAN /ELEC ROOM IN H &M SPACE. VERIFY IN FIELD EXACT LOCATION OF MAIN TELEPHONE BOARD AS WELL AS ANY INTERMEDIATE BOARD LOCATIONS AND CABLE TRAY. TECHNOLOGY CONTRACTOR TO PROVIDE CAT.5 RATED 25 —PAIR CABLE, PLENUM RATED, FROM LL TELEPHONE CLOSET TO H &M SPACE VIA LL'S CABLE TRAY AND CONDUIT IN SPACE. (APPROX 300' —O' +/—). REFER TO SPECIFICATION SECTION 16740.M.12 FOR MORE INFORMATION. COORDINATE REQUIRM DISTANCE WITH LL PRIOR TO SUBMITTING BID. EC. SHALL COORDINATE LOCATION OF SMART JACK, FOR H &M WITH TELEPHONE COMPANY, TO BE LOCATED WITHIN 300 FEET OF THE H &M SPACE. NOTE: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT IE.M.T• oR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. ENLARGED CASH OFFICE PLAN NO SCALE ALSO SEE CASH ROOM WALL ELEVATION(S), THIS SHEET. CODED NOTES 01 (4) DATA JACKS ® QUAD I.G. MOUNTED ABOVE CEILING AT DOOR FOR POWER TO DOOR LOCK. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEI {7 EL, APR 16 2006 PERMIT CENTEEt US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES EXPIRES SEP 0 3 2009 ■■ THORSON BAKER 3030 West Streetsboro Road Richfield, Ohio 44286 & Associates, Inc. Consulting Engineers (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A\ 03/19/08 ADDENDUM B Project No. Scale DrarnBy: 43328 AS NOTED JDM Y: \2008 \2008-0049 \Cad \Mep \2008- 0049E4 -1.dwg Droving No. ELECTRICAL DETAILS & ENLARGED PLANS E4.1 I i CASH REGISTER i • _1 i CASH REGISTER L._ .__. — _ J )VER PLATE . t 3 6 L 13 0 0 0 �� I © g P 1; l uno PT PT PT PT � 1I (1) QUAD CONVENIENCE RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. — (1) QUAD ISOLATED GROUND RECEPTACLE MOUNTED TO BACK SIDE OF MILLWORK LOCATED DIRECTLY UNDER THE ACCESS COVER PLATE BELOW FOLDING AREA/ SELVES FOR BAGS (TYPICAL). SYMBOL ON DWG. — SECTION A -A DATA • A ii DATA DATA JACKS MOUMED VER11CALLY IN SURFACE BOX TO BACK SIDE OF MILLWORK. PROVIDE (5) DATA JACKS FOR EACH PAIR OF REGISTERS AT EACH CASHWRAP LOCATION. LOCATE DIRECTLY UNDER ACCESS COVER PLATE BELOW FOLDING AREA/SELVES FOR BAGS. SEE POWER PLANS FOR EXACT QUANTITY OF DATA JACKS REQUIRED. SYMBOL ON DWG. — v (#D) BACK VIEW CASH WRAP ELEVATION -CORE DRILL I.G. ELEVATION "B" FINISHED FLOOR FIRE RATED POKE — THROUGH FOR CASH WRAP BRANCH CIRCUIT ISOLATED GROUND POWER WIRING. PROVIDE (1) HUBBELL PT7XC WITH 2 —GANG PEDESTAL SERVICE FITTING FR8OAL AND FURNITURE FEED OPENING SS309SF. USE 1 -1/4' STEM FOR POWER WIRING. BRANCH TO DEVICES VIA UQUIDTIGHT FLEXIBLE METALLIC CONDUIT. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. — ED ROUTE NORMAL POWER WIRING VIA THE 1/211C. STEM IN THE HUBBELL FIRE RATED POKE — THROUGH. PROVIDE AN SS309SF FACE PLATE FOR NORMAL POWER. BRANCH TO DEVICES VIA LIQUIDTIGHT FLEXIBLE METAWC CONDUIT. FIRE RATED POKE — THROUGH FOR DATA WIRING FOR CASH WRAP. PROVIDE (1) HUBBELL PT7XC WITH 2 —GANG PEDESTAL SERVICE FITTING FR8OAL AND BUSHED DATA OPENING FACE PLATE SS309T. USE 1 -1/4' STEM FOR DATA WIRING. (QUANTITY AS SHOWN ON PLANS) SYMBOL ON DWG. — NO SCALE GENERAL NOTES 1. REFER TO DRAWING E3.1 FOR QUANTITY AND LOCATIONS OF ALL POWER AND DATA DEVICES. 2. ALL JACKS ARE ARBITRARILY LABELED AS DATA, AS DATA AND TELEPHONE USE THE SAME JACKS. THE H &M I.T. REPRESENTATIVE SHALL DETERMINE WHICH JACKS ARE FOR DATA AND WHICH ARE FOR TELEPHONES. (TYPICAL) 3. ALL FLOOR CONDUIT PENETRATIONS SHALL BE FIRE RATED OR FIRE STOPPED AS REQUIRED BY THE LOCAL JURISDICTION AND /OR LANDLORD. 4. PROVIDE HUBBELL S5309B BLANK FACEPLATES FOR UNUSED PEDESTAL COMPARTMENTS. LP2 -5 120VAC -1 0 PUSHBUTTON — EDWARDS 1600 QUANTITY AS INDICATED ON PLANS. WIRE PUSHBUTTONS IN PARALLEL TRANSFORMER — EDWARDS 590 MOUNTED TO 4' SQ. BOX ON WALL IN STOCK ROOM. BUZZER(S) — EDWARDS 1661 FLUSH MOUNTED 8' -0 A.F.F. AT BACK OF HOUSE OR ON CEILING IN SALES AREA. QUANTITY AS INDICATED ON PLANS. DOORBELL WIRING DIAGRAM NO SCALE NOTE ALL LOW VOLTAGE WIRING TO BE #14AWG. 120VAC, LP3 -12 (CONTROLLED C B ZONE 1) R1 -} CONTROL RELAY: CUTLER — HAMMER jD15CR22AB MTH (2) N.O. CONTACTS AND (2) N.C. CONTACTS, MOUNTED IN A NEMA 1 ENCLOSURE ABOVE THE CASH OFFICE LAY —IN CEILING. PROVIDE A CUTLER— HAMMER 1C321 MP1 MOUNTING PLATE. ENCLOSURE SHALL BE HOFFMAN #A8N86 WITH HOFFMAN IA8N8P BACK PANEL TO I-IVAC CONTROL PANEL WIRING BY EC. COORDINATE WITH T.C. CONTRACTOR WIRING DIAGRAM - LIGHTING CONTROL TIE -IN TO HVAC CONTROLS NO SCALE T —ISO HUNG FROM STRUCTURE ABOVE PNLS ENLARGED ELECTRIC /LAN ROOM PLAN NO SCALE EC. SHALL COORDINATE ALL ELECTRICAL EQUIPMENT LOCATIONS WITH THE MECHANICAL AND PLUMBING TRADES. CODED NOTES (6) QUAD I.G. RECEPTACLES EVENLY SPACED BEHIND AUDIO RACK FOR SOUND SYSTEM POWER. K2 JUNCTION BOX AND QUAD I.G. RECEPTACLE FOR SECURITY PANEL 0 JUNCTION BOX FOR SPEAKER WIRING. 4'H.x4'W.x3 /4b. TO BOTTOM. RE TREATED PLYWOOD BOARD. MOUNT AT 24' A.F.F. DATA RACK FLOORSTANDING WITH SUFFICIENT SPACE TO OPEN FRONT AND BACK DOORS ON PLYWOOD BOARD. REFER TO SPECIFICATIONS FOR RACK REQUIREMENTS. QUAD OUTLET SHALL BE INSTALLED BY EC. IN CENTER OF THE RACK TO COORDINATE WITH RAIL LOCATIONS. EC. SHALL MODIFY RACK ACCORDINGLY TO ACCOMMODATE THE OUTLET. 1- 1/2'C. W /PULLSTRING BY H &M'S EC. FOR TELEPHONE SERVICE FROM LL CABLE TRAY TO LAN /ELEC ROOM IN H &M SPACE. VERIFY IN FIELD EXACT LOCATION OF MAIN TELEPHONE BOARD AS WELL AS ANY INTERMEDIATE BOARD LOCATIONS AND CABLE TRAY. TECHNOLOGY CONTRACTOR TO PROVIDE CAT.5 RATED 25 —PAIR CABLE, PLENUM RATED, FROM LL TELEPHONE CLOSET TO H &M SPACE VIA LL'S CABLE TRAY AND CONDUIT IN SPACE. (APPROX 300' —O' +/—). REFER TO SPECIFICATION SECTION 16740.M.12 FOR MORE INFORMATION. COORDINATE REQUIRM DISTANCE WITH LL PRIOR TO SUBMITTING BID. EC. SHALL COORDINATE LOCATION OF SMART JACK, FOR H &M WITH TELEPHONE COMPANY, TO BE LOCATED WITHIN 300 FEET OF THE H &M SPACE. NOTE: IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO PROPERLY BALANCE ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM, REGARDLESS OF THE CIRCUIT INDICATED. ALL WIRING SHALL BE IN CONDUIT IE.M.T• oR RIGID FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC., MAX. LENGTH 6 FEET. ENLARGED CASH OFFICE PLAN NO SCALE ALSO SEE CASH ROOM WALL ELEVATION(S), THIS SHEET. CODED NOTES 01 (4) DATA JACKS ® QUAD I.G. MOUNTED ABOVE CEILING AT DOOR FOR POWER TO DOOR LOCK. THE ELECTRICAL CONTRACTOR SHALL VERIFY EXISTING CONDITIONS TO INSURE THAT THE NEW WORK WILL FIT TO THE EXISTING STRUCTURE IN THE MANNER INTENDED AND SHOWN ON THE DRAWINGS. SHOULD ANY CONDITIONS EXIST THAT ARE CONTRARY TO THOSE ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE TENANT'S REPRESENTATIVE PRIOR TO FABRICATION OR PERFORMING ANY WORK IN THE AREA INVOLVING DIFFERENCES. NOTIFICATION SHALL BE IN THE FORM OF A DRAWING OR SKETCH INDICATING FIELD MEASUREMENTS AND NOTES RELATED TO THE AREA. RECEI {7 EL, APR 16 2006 PERMIT CENTEEt US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 EXPIRES EXPIRES SEP 0 3 2009 ■■ THORSON BAKER 3030 West Streetsboro Road Richfield, Ohio 44286 & Associates, Inc. Consulting Engineers (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A\ 03/19/08 ADDENDUM B Project No. Scale DrarnBy: 43328 AS NOTED JDM Y: \2008 \2008-0049 \Cad \Mep \2008- 0049E4 -1.dwg Droving No. ELECTRICAL DETAILS & ENLARGED PLANS E4.1 TBA Dwg Name: 2008- 0048E4• -2.dwg Scale: 1' •1' -0" Date: Mar. 18, 2008 lime: 2:12 pm Plotted Tuesday March 18, 2008 2:12pm by ataylor H 120V (LP2 -5) N T/C P/C TC1 C -1 LP1- 79,81,83 ---� LP1- 80,82,84 LP3 -8,10 T/C — TIMECLOCK, INTERMATIC fET171C MOUNTED ADJACENT TO PANEL 'HP1". P/C — PHOTOCELL, INTERMAIIC #K4221 MOUNTED AT ROOF. FACE SENSOR NORTH. EXTERIOR LIGHTING, SIGNAGE, AND BLADE SIGNAGE SIGNAGE CONTROL DIAGRAM NTS NOTE TIMECLOCK TO BE ADJUSTED PER LANDLORD SPECIFICATIONS SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 LIGHTING CONTROL SCHEDULE LIGHTING ZONE CIRCUIT(S) FUNCTION CONTROL SEQUENCE NOTES Z1 HP1- 3,7,11,13,17,21,25,29 CLEANING LTG. (50 %), QL ON — WHEN BURGLAR ALARM CODE IS ENTERED (DEACTIVATED) 1 LP3 -1 LTG AND B —O —H LTG OFF — WHEN BURGLAR ALARM IS REACTIVATED Z2 HP1- 2,6,8,12,16,18,22 GEN. SALES LTG. (50 %) ON — TIMED AFTER BURGLAR ALARM CODE IS ENTERED (DEACTIVATED) 1,2 LP3 -2 OFF — I1ME0, 02 WHEN BURGLAR ALARM IS REACTIVATED Z2 LP1- 1,3,5,7,9,11,13,15,17, 19,21,23,25,27,29,31,33,35, TRACK LTG ALARM CODE I ISRENTERED (DEACTIVATED) OFF — TIMED, 0 WBUR BURGLAR 1,2 37,39,41,43,45,47,49,51,53, 55,57,59,61,63,65,67,69,71, 73,75,77 LP1-2,4,6,8,10,12,14,16,18, 20,22,24,26,28,30,32,34,36, 38,40,42,44,46,48,50,52,54, 56,58,60,62,64,66,68,70,72, 74,76,78 Z2 LP3- 3,5,7,9,10 MIRROR LTG, POP —OUT ON — TIMED AFTER BURGLAR ALARM CODE IS ENTERED (DEACTIVATED) 1,2 LP3 -4,6 L WALLS, WATER COOLER, OFF — TIMED, .E WHEN BURGLAR ALARM IS REACTIVATED TC1 LP1- 79,81,83 SHOW WINDOW TRACK ON — TIMED 4 LP1- 80,82,84 AND SIGNAGE OFF — TIMED LP3 -8,10 Z1 LP3 -12 TEMP. CTL. RELAY ON — WHEN BURGLAR ALARM CODE IS ENTERED (DEACTIVATED) 1,3 OFF — WHEN BURGLAR ALARM IS REACTIVATED POWERUNK POWER SUPPLY POWERUNK 3000 SERIES CONTROLLER POWERUNK MASTER PANEL (HP1) 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBLG3 WITH SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSELG3 INPUT TERMINAL BURGLAR ALARM SWITCH.. REFER INPUT TERMINAL DIAGRAM. SUBNET CABLE (CLASS 1), 4 —WIRE, I18AWG, BELDEN •27326 TYPICAL BETWEEN PANELS) WIRING TO AND KEY TO POWERUNK WIRING SUBNET CABLE (CLASS 1), 4 —WIRE, 18AWG, BELDEN #27326 ICAL BETWEEN PANELS) NOTES: 1. REFER TO POWERUNK INPUT TERMINAL WIRING DIAGRAM ON THIS DRAWING FOR BURGLAR ALARM SYSTEM ENABLING OF THE UGHIING CONTROLLER. THE LIGHTING SHALL BE ENABLED VIA A NORMALLY OPEN DRY CONTACT FROM THE BURGLAR ALARM SYSTEM SUCH THAT DEACTIVATION OF THE BURGLAR ALARM SYSTEM SHALL ENABLE ZONE 1 AND THE LIGHTING CONTROLLER TIMER. REACTIVATION OF THE BURGLAR SYSTEM SHALL DISABLE THE LIGHTING CONTROLLER. NOTE THAT THE KEY SWITCH AND /OR OVERRIDE SWITCH(ES) ALSO PERFORM THE SAME FUNCTION. 2. THE EC SHALL OBTAIN ON /OFF PROGRAM TIMES FROM THE ON —SITE H &M REPRESENTATIVE AND PROVIDE THIS INFORMATION TO SQUARE D NO LESS THAN 14 DAYS BEFORE SCHEDULED SYSTEM START —UP. 3. CONTROLLED CIRCUIT (LP3-12) SHALL BE USED TO CONTROL A RELAY COIL THE RELAY SHALL PROVIDE A NORMALLY OPEN CONTACT FOR USE BY TEMPERATURE CONTROL SYSTEM TO DETERMINE THE STATUS OF THE STORE AS 'OCCUPIED" (RELAY CONTACT CLOSED) OR "UNOCCUPIED' (RELAY CONTACT OPEN). REFER TO 'UGHTING 'WIRING DIAGRAM — LIGHTING CONTROL TIE —IN TO IiVAC CONTROLS' DETAIL ON DRAWING E4.1. 4. SEE TIME CLOCK DETAIL THIS SHEET. THE EC. SHALL OBTAIN ON /OFF PROGRAM TIMES FROM THE LANLORD. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 5 'inn City Of Txui +afl2 BUILDING DI'= SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBLG3 WffH SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSELG3 EC. SHALL PROVIDE (1) CAT. 5 SHIELDED CABLE TO DATA RACK WITH STANDARD CAT. 5 CONNECTOR TERMINATION AT PANEL SIDE, THEN PUNCH DOWN OTHER END AT DATA RACK B, PORT NUMBER 24 IN ELECTRICAL ROOM. LABEL PORT 'UGHTING SYSTEM'. 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBRG3 WIRING TO OVERRIDE SWITCHES REFER TO POWERUNK INPUT TERMINAL WIRING DIAGRAM. _r WIRING TO OCCUPANCY SENSOR POWER PACKS. EXACT QUANTITY TO BE DETERMINED. 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBRG3 POWERUNK SLAVE PANEL (LP1 — SECTION 1) SQUARE D "POWERLINK" LIGHTING CONTROL WIRING DIAGRAM NO SCALE 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBLG3 WITH SLAVE ADDRESS SELECTOR, SQUARE D CAT No NFSELG3 21 SPACE CONTROL BUS, SQUARE D CAT No. NF21SBRG3 POWERUNK SLAVE PANEL (LP1 — SECTION 2) NOTE: 1. THE COMPLETE POWERUNK LIGHTING CONTROL SYSTEM — PANELS, POWER SUPPLY, CONTROLLER, CONTROL BUSES, SLAVE BUS HARNESS AND CONTROLLABLE CIRCUIT BREAKERS SHALL BE FURNISHED, INSTALLED AND WIRED BY THE EC. 2. THE TOTAL NUMBER OF CONTROLLABLE BREAKERS SHALL BE EQUAL TO THE TOTAL NUMBER OF CONTROL BUS POSFONS IN EACH POWERUNK PANEL 3. SUBNET CABLE SHALL BE FURNISHED AND INSTALLED BY THE EC. 4. BURGLAR ALARM DRY CONTACT (INPUT No.1) SHALL BE FURNISHED BY H&M AS PART OF THE BURGLAR ALARM SYSTEM, AND INSTALLED & WIRED BY THE EC. 5. LIGHTING CONTROL KEY SWITCH (INPUT No.1) SHALL BE FURNISHED BY H &M AND INSTALLED & WIRED BY THE EC. 18 SPACE CONTROL BUS, SQUARE D CAT No. NF18SBLG3 WITFI SLAVE ADDRESS SELECTOR, SQUARE D CAT No. NFSELG3 SLAVE BUS CONNECT HARNESS SQUARE D CAT No. NF2HG3 18 SPACE CONTROL BUS, SQUARE D CAT No. NF18SBRG3 POWERUNK SLAVE PANEL (LP3) US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 t EXPIRES 9. 3 - 0 THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road (330) 659 -6656 Ph. Richfield, Ohio 44266 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 ADDENDUM A r CITY OF 1 urrv. :_A MAR 1 Q 71108 PEP'CiV910 Project Ho. 43328 Scale AS NOTED DravnBy: JDM Y :\ 2008\ 2008 - 0049 \Cad\Mep \Recordsat\ADDENDUM A2008-0049E4-44 E4.2 .EXPRES . 3 - 1 TBA Dwg Name: 2008- 0049E4 -3.dwg Scale: 1'■=1' -0° Date: Mar. 18, 2008 Time: 2:13 pm Plotted Tuesday March 18, 2008 2:12pm by ataylor 112 AWG TO STRUCTURE ABOVE CEILING, TYPICAL TYPICAL FIXTURE 114 SUSPENDED CEIIJNG. TYPICAL LIGHT FIXTURE SEISMIC SUPPORT DETAIL NO SCALE SEISMIC BRACING NOTES 1. COMPLY WO SEISMIC RESTRAINT REQUIREMENTS IN THE WASHINGTON BUILDING CODE AND LOCAL BUILDING CODES, UNLESS REQUIREMENTS IN THIS SECTION ARE MORE STRINGENT. 2. PROJECT SEISMIC ZONE AND ZONE FACTOR AS DEFINED IN UBC: ZONE 4, ZONE FACTOR 0.4 OCCUPANCY CATEGORY AS DEFINED IN UBC: N SEISMIC IMPORTANCE FACTOR: 1.5 WIND IMPORTANCE FACTOR: 1.0 ACCELERATION FACTOR: 0.45G FOR RIGID EQUIPMENT ACCELERATION FACTOR: 0.9G FOR FLEXIBLE EQUIPMENT 3. COORDINATE LAYOUT AND INSTALLATION OF SEISMIC BRACING WITH BUILDING STRUCTURAL SYSTEM AND ARCHITECTURAL FEATURES, AND WITH MECHANICAL, FIRE — PROTECTION, ELECTRICAL, AND OTHER BUILDING FEATURES IN THE VICINITY. 4. ACCEPTABLE MANUFACTURERS FOR SEISMIC BRACING DEVICES: B —LINE SYSTEMS, INC. ERICO, INC. GS METALS CORP. MASON INDUSTRIES, INC, THOMAS & BETTS CORP. UNISTRUT CORPORATION. 5. INSTALL SEISMIC RESTRAINTS ACCORDING TO APPLICABLE CODES AND REGULATIONS AND AS APPROVED BY AUTHORITIES HAVING JURISDICTION, UNLESS MORE STRINGENT REQUIREMENTS ARE INDICATED HEREWITH: ANCHOR RIGIDLY TO A SINGLE MOBILE STRUCTURAL ELEMENT OR TO A CONCRETE BASE THAT IS STRUCTURALLY TIED TO A SINGLE MOBILE STRUCTURAL ELEMENT. ANCHOR PANELBOARDS, TRANSFORMERS, FUSED POWER— CIRCUIT DEVICES, COMMUNICATION SYSTEM COMPONENTS, AND ELECTRONIC SIGNAL PROCESSING, CONTROL, AND DISTRIBUTION UNITS AS FOLLOWS: SIZE CONCRETE BASES SO EXPANSION ANCHORS WILL BE A MINIMUM OF 10 BOLT DIAMETERS FROM THE EDGE OF THE CONCRETE BASE. ANCHOR BOLT BUSHING ASSEMBLIES FOR WALL — MOUNTED EQUIPMENT: INSTALL TO ALLOW FOR RESILIENT MEDIA WHERE EQUIPMENT OR EQUIPMENT — MOUNTING CHANNELS ARE ATTACHED TO WALL TORQUE BOLTS AND NUTS ON STUDS TO VALUES RECOMMENDED BY EQUIPMENT MANUFACTURER. MAKE FLEXIBLE CONNECTIONS IN RACEWAYS, CABLES, AND WIREWAYS WHERE THEY CROSS EXPANSION AND SEISMIC CONTROL JOINTS, WHERE ADJACENT SECTIONS OR BRANCHES ARE SUPPORTED BY DIFFERENT STRUCTURAL ELEMENTS, AND WHERE THEY TERMINATE AT ELECTRICAL EQUIPMENT ANCHORED TO A DIFFERENT MOBILE STRUCTURAL ELEMENT FROM THE ONE SUPPORTING THEM. f(E) CONC. SLAB ON METAL DECK /(E) BEAM NOT SHOWN FOR CLARITY P5500 (MIN.) UNISTRUT, TYP. P2786 UNISTRUT CLAMP, TYP. 6' MIN. TYP. EA. EDGE OF UNIT L4x4x1 /4, TYP. ATTACHMENT OF T —ISO TO MC6 BY MFR. s <Np (2)— C4x4.5 EA. END OF UNIT T -ISO MOUNT DETAIL HSS3x3x+ c I . "x10 "x0' -1O" (E) FLOOR SLAB 8 " THREADED ROD STACKED TRANSFORMER SECTION L5x5x5/1 6 BRACE (SEE PLAN) TO TOP FLANGE OF BEAM L4x4 STACKED TRANSFORMER SECTION REVIEWED OMPL CE CODE APPROVE MAR r. 700f City Of Tukwila BUILDING DP/1510N A US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 .. THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield. Ohio 44286 (330) 659 -6688 Ph. 330) 659 -6675 Fax QAQC No. Date 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID A 03/18/08 ADDENDUM A Issue r.. -r.. nc A MAR 19 2003 PERMIT CENTER Project No. Scale DravnDy: 43328 AS NOTED JDM { i4 Y:\ 2008 \2008 -0049 \Cad \Map \Rec:ordset\ADDENDUM A \2008-0049E4 -3.d Droving No. ELECTRICAL EQUIPMENT SEISMIC DETAILS E4.3 TBA Dwg Name: 2008- 0049E5 -1.dwg Scale: 1' =1' -0" Date: Apr. 14, 2008 Time: 1:23 pm Plotted Monday April 14, 2008 1:22pm by gsimon H &M SOUTHCENTER US159 TUKWILA, WASHINGTON TBA 12008 -0049 SHEET 1 OF 3 ELECTRICAL SPECIFICATLQN INDEX SECTION 16010 - GENERAL PROVISIONS SECTION 16050 - BASIC ELECTRICAL MATERIALS AND METHODS SECTION 16060 - GROUNDING AND BONDING SECTION 16120 - WIRE AND CABLE SECTION 16130 - RACEWAYS AND BOXES SECTION 16140 - WIRING DEVICES SECTION 16410 - SAFETY SWITCHES SECTION 16420 - MOTOR STARTERS SECTION 16442 - DISTRIBUTION AND PANELBOARDS SECTION 16461 - DRY TYPE TRANSFORMERS SECTION 16491 - FUSES SECTION 16511 - LIGHTING FIXTURES SECTION 16740 - COMMUNICATIONS CONDUIT, CABLING AND EQUIPMENT SECTION 16800 - FAULT CURRENT STUDY SECTION 16810 - SOUND EQUIPMENT SECTION 16010 - GENERAL PROVISIONS A. GENERAL 1. REQUIREMENTS SPECIFIED IN DMSION 1, INSTRUCTIONS TO BIDDERS, SUPPLEMENTAL GENERAL CONDITIONS, SPECIAL CONDITIONS, ADDENDA, ALTERNATES, CONTRACT AND PROPOSAL, ALONG WITH DMSION 16 AND ALL ITS SECTIONS, COMPRISE THE CONTRACT DOCUMENTS FOR THE ELECTRICAL CONTRACT. DRAWINGS AND ALL THEIR REVISIONS UP TO THE BID SUBMITTAL DATE BECOME A BINDING PART OF THE CONTRACT, ALONG WITH THESE SPECIFICATIONS AS THOUGH THEY WERE ONE, AND ANYTHING IMPLIED BY THE SPECIFICATIONS SHALL BE INTERPRETED AS ALSO IMPLIED BY THE DRAWINGS AND VICE VERSA. PROVIDE NECESSARY ITEMS FOR A COMPLETE INSTALLATION OF ALL ELECTRICALLY OPERATED EQUIPMENT US I ED IN THE SPECIFICATIONS OR SHOWN ON THE CONTRACT DRAWINGS. 2. THE ARCHITECTURAL STRUCTURAL, MECHANICAL, PLUMBING AND EQUIPMENT DRAWINGS AND SPECIFICATIONS ARE INCORPORATED INTO, AND BECOME A PART OF THIS DMSION. THIS CONTRACTOR SHALL EXAMINE AIL SUCH DRAWINGS AND SPECIFICATIONS AND BECOME THOROUGHLY FAMILIAR WITH THE PROVISIONS CONTAINED THEREIN. THE SUBMISSION OF HIS BID SHALL INDICATE SUCH KNOWLEDGE 3. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. THEY ARE INTENDED TO SHOW THE APPROXIMATE LOCATIONS OF EQUIPMENT AND CONDUIT. DIMENSIONS GIVEN ON THE PLANS, IN FIGURES, SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALT. BE VERIFIED IN THE FIELD. THE ELECTRICAL CONTRACTOR SHALL LAYOUT ALL EQUIPMENT ROOMS TO MAKE SURE THE EQUIPMENT, AS PURCHASED, FITS IN THE ROOM OR SPACE SHOWN. EXACT LOCATION OF ALL EQUIPMENT SHALL BE VERIFIED IN THE FIELD AND ROUTING OF CONDUITS SHALL SUIT FIELD CONDmONS. 4. UNTIL THE TIME OF INSTALLATION, THE ARCHITECT RESERVES THE RIGHT TO MAKE MINOR CHANGES IN THE LOCATION OF CONDUIT AND EQUIPMENT WITHOUT ADDMONAL COST TO THE CONTRACT. 5. THE ELECTRICAL DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER. MATERIAL AND LABOR NECESSARY TO THE PROJECT SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. LABOR AND /OR MATERIALS NEITHER SHOWN NOR SPECIFIED, BUT OBVIOUSLY NECESSARY FOR THE COMPLETION AND PROPER FUNCTIONING OF THE SYSTEM, SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. 6. ARRANGE ALL EQUIPMENT SUBSTANTIALLY AS SHOWN ON THE DRAWINGS. MAKE DEVIATIONS ONLY WHERE NECESSARY TO AVOID INTERFERENCE. CHECK ALL EQUIPMENT SIZES AGAINST AVAILABLE SPACE PRIOR TO SHIPMENT TO AVOID INTERFERENCE 7. EXAMINE THE WORK OF OTHER TRADES INSOFAR AS THOR WORK COMES IN CONTACT WITH OR IS COVERED BY THIS WORK IN NO CASE ATTACH TO, OR FINISH AGAINST ANY DEFECTIVE WORK OR INSTALL WORK IN A MANNER WHICH WILL PREVENT PROPER INSTALLATION OF THE WORK OF OTHER TRADES. 8. ELECTRICAL CONTRACTOR SHALL VERIFY WITH OTHER TRADES ALL ELECTRICAL CHARACTERISTICS OF EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS, CONTRACTOR SHALL VERIFY VOLTAGE, PHASE AND HORSEPOWER AND SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO START OF WORK. ELECTRICAL CONTRACTOR SHALL PROVIDE DISCONNECTING MEANS AND OVERLOAD PROTECTION FOR ALL EQUIPMENT, UNLESS FURNISHED INTERGRAL WITH EQUIPMENT PACKAGE. 9. IT IS THE NOT OF THESE DRAWINGS THAT THIS BE A COMPU=TE ELECTRICAL JOB, ANY ERRORS OR OMISSIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER PRIOR TO BIDDING THE JOB. B. VISIT TO THE SEFE 1. THIS CONTRACTOR SHALL VISIT THE SITE OF THE WORK AND FAMILIARIZE HIMSELF WITH ALL CONDIONS AFFECTING HIS WORK. THE SUBMISSION OF HIS PROPOSAL SHALL INDICATE SUCH KNOWLEDGE NO ADDMONAL PAYMENT SHALL BE MADE ON CLAIMS THAT ARISE FROM A LACK OF KNOWLEDGE OF THE EXISTING CONDmONS. C. CODE AND PERMITS 1. INSTALLATION SHALL BE IN FULL ACCORDANCE WITH ALL CODES, RULES AND REGULATIONS OF MUNICIPAL, CITY, COUNTY, STATE AND PUBLIC UTILITIES, EDUON OF THE NATIONAL ELECTRICAL CODE BEING ENFORCED AND ALL OTHER AUTHORITIES HAVING JURISDICTION OVER THE PREMISES. 2. COMPLY WITH ANY SPECIFICATION REQUIREMENTS THAT ARE IN EXCESS BUT NOT IN CONFLICT WITH CODE REQUIREMENTS. 3. THE CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, PLAN REVIEWS AND CERTIFICATES OF INSPECTION IN CONNECTION WITH HIS WORK, REQUIRED BY THE FOREGOING AUTHORmES. BEFORE FINAL PAYMENT OF THE CONTRACT IS ALLOWED, ALL CERTIFICATES SHALL BE DELM=RED TO THE ARCHITECT IN DUPLICATE 4. ELECTRICAL MATERIAL AND EQUIPMENT SHALL BEAR THE UL LABEL EXCEPT WHERE UL DOES NOT LABEL SUCH TYPES OF MATERIAL AND EQUIPMENT. D. SHOP DRAWINGS SUBMITTALS 1. THE ELECTRICAL CONTRACTOR SHALL SUBMIT FNE (5) SETS OF SHOP DRAWINGS, THE SHOP DRAWINGS OF THE FOLLOWING EQUIPMENT USING THE INDICATED NUMBERING SYSTEM AND TITLES, SHALL BE SUBMITTED THROUGH THE ARCHITECT TO THE ENGINEER AND THEN RESUBMITTED FOR FINAL APPROVAL IF NECESSARY. SHOP DRAWINGS SHALL BE SUBMITTED FOR THE FOLLOWING ITEMS: A WIRING DEVICES B. PANELBOARDS, TRANSFORMERS AND SAFETY SWITCHES INCLUDING FAULT CURRENT STUDY BASED ON EQUIPMENT BEING SUPPLIED. C. PANELS AND LIGHTING CONTROL SYSTEM D. LIGHTING FIXTURES E. COMMUNICATIONS CABLING AND EQUIPMENT F. SUPERVISORY ALARM SYSTEM 2. ALL SUBMITTED SHOP DRAWINGS (MANUFACTURERS' EQUIPMENT DESCRIPTIVE SHEETS OR VENDORS' PREPARED DRAWINGS) SHALL HAVE THE GENERAL CONTRACTOR'S OR SUBCONTRACTOR'S 'STAMP OF APPROVAL" INDICATING THAT THE ITEM SUBMITTED IS AS CALLED FOR ON THE PLANS AND SPECIFICATIONS, IS APPROVED BY THE GENERAL CONTRACTOR OR SUBCONTRACTOR, THE DATE OF APPROVAL AND INITIALED BY THE PERSON APPROVING THE SUBMITTAL AND THE NAME OF THE COMPANY SUBMITTING SAID EQUIPMENT FOR APPROVAL 3. SUBMIT BOUND BROCHURES COMPLETE WITH A TABLE OF CONTENTS. LOOSE OR STAPLED TOGETHER SHEETS ARE NOT ACCEPTABLE. ANY SUBMITTALS NOT IN BROCHURE FORM OR NOT AS SPECIFIED SHALL BE RETURNED AT THE CONTRACTOR'S EXPENSE FOR RESUBMTTAL 4. ALL DESCRIPTIVE LITERATURE SHALL BE SUBMITTED IN A THREE (3) HOLE BROCHURE WITH A COVER IDENTIFYING THE FOLLOWING: A. NAME OF THE JOB. B. LOCATION OF THE JOB, ADDRESS, CITY AND STATE. C. NAME AND ADDRESS OF THE COMPANY SUBMITTING THE BROCHURES. D. DATE OF THE SUBMITTAL 5. EVERY EFFORT SHALL BE MADE, IN CHECKING THE SHOP DRAWINGS, TO DETECT AND CORRECT ALL ERRORS, OMISSIONS AND INACCURACIES. FAILURE TO DO THIS WILL NOT RELIEVE THE ELECTRICAL CONTRACTOR OF THE RESPONSIBILITY FOR THE PROPER AND COMPLETE INSTALLATION IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. E. AS -BUILT DRAWINGS 1. SUBMIT TO THE ARCHITECT ONE SET OF REPRODUCIBLE (MYLARS) ELECTRICAL DRAWINGS SHOWING THE AS -BUILT CONDITIONS. F. STANDARDS AND SUBSTITUTIONS 1. WHEREVER THE WORDS "APPROVED BY', 'APPROVED EQUAL ", AS DIRECTED' OR SIMILAR PHRASES ARE USED IN THE FOLLOWING SPECIFICATIONS, THEY SHALL BE UNDERSTOOD TO REFER TO THE OWNER AS THE APPROVING AGENCY. THE NAME OR MAKE OF ANY EQUIPMENT OR MATERIALS NAMED IN THIS SPECIFICATION (WHETHER OR NOT THE WORDS OR APPROVED EQUAL' ARE USED) SHALL BE KNOWN AS THE "STANDARD ". 2. THESE SPECIFICATIONS ESTABLISH QUALITY STANDARD OF MATERIALS AND EQUIPMENT TO BE PROVIDED. SPECIFIC ITEMS ARE IDENTIFIED BY MANUFACTURER, TRADE NAME OR CATALOG DESIGNATION. THIS CONTRACTOR SHALL SUBMIT HIS BASE BID PRICE BASED UPON STANDARD SPECIFIED EQUIPMENT DESCRIBED HEREIN AND AS DETAILED ON DRAWINGS AND ASSOCIATED CONTRACT DOCUMENTS. THESE SPECIFICATIONS ARE NOT TO BE CONSIDERED PROPRIETARY THE CONTRACTOR MAY SUBMIT INFORMATION ON MATERIALS AND MANUFACTURERS (OTHER THAN THOSE US I ARCHITECT AND ENGINEERS O FOR LATER THAN TEN (10) DAYS BEFORE BIDS ARE SUBMI I ILO. IN ADDITION, SAMPLES OF PROPOSED EQUIPMENT MAY BE REQUIRED TO BE SUBMIIIEL) TO THE ENGINEER FOR REVIEW NO LATER THAN TEN (10) DAYS BEFORE BIDS ARE SUBMI I I ELL MANUFACTURERS OF PRODUCTS ACCEPTED BY THE ARCHITECT AND ENGINEER WILL BE LISTED IN AN ADDENDUM TO THE SPECIFICATIONS AS AN ACCEPTABLE SUBSTITUTION EQUIPMENT ACCEPTED AS DETAILED BELOW AND SHALL BE SHOWN AS A SEPARATE ADD OR DEDUCT PRICE TO BE FACTORED INTO THE BASE BID PRICE BY THE ARCHITECT AND OWNER IF ACCEPTED. 3. SHOULD THE CONTRACTOR PROPOSE TO FURNISH MATERIALS AND EQUIPMENT OTHER TI-IAN THOSE SPECIFIED OR APPROVED BY ADDENDUM. SUBMIT A WRITTEN REQUEST FOR SUBSTITUTIONS TO THE ARCHITECT AT THE BID OPENING. THE REQUEST SHALL BE AN ALTERNATE TO THE ORIGINAL BID; BE ACCOMPANIED WITH COMPLETE DESCRIPTIVE (MANUFACTURER, BRAND NAME, CATALOG NUMBER, ETC.) AND TECHNICAL DATA FOR ALL ITEMS. FAILURE BY THIS CONTRACTOR TO SUBMIT THE REQUISITE DOCUMENTATION DETAILED ABOVE SHALL BE UNDERSTOOD BY THE ARCHITECT AND ENGINEER TO INDICATE THAT SUBSTITUTE EQUIPMENT WILL NOT BE PRESENTED BY THE CONTRACTOR FOR CONSIDERATION. SUCH SUBSTITUTIONS WILL NOT BE CONSIDERED AFTER THE BID OPENING DATE AND DELAY OF PROJECT WILL NOT BE PERMITTED FOR FURTHER INSPECTION AND EVALUATION AFTER THIS DATE. 4. WHERE SUCH SUBSTITUTIONS ALTER THE DESIGN OR SPACE REQUIREMENTS INDICATED ON THE DRAWINGS, INCLUDE ALL ITEMS OF COST FOR THE REMISED DESIGN AND CONSTRUCTION INCLUDING COST OF ALL AWED TRADES INVOLVED. 5. ACCEPTANCE OR REJECTION OF THE PROPOSED SUBSTITUTIONS SHALL BE SUBJECT TO APPROVAL OF THE ARCHITECT AND ENGINEER. IF REQUESTED, THE CONTRACTOR SHALL SUBMIT (AT HIS COST) INSPECTION SAMPLES OF BOTH THE SPECIFIED AND PROPOSED SUBSTITUTE ITEMS. 6. IN ALL CASES WHERE SUBSTITUTIONS ARE PERMITTED, THE CONTRACTOR SHALL BEAR ANY EXTRA COST OF EVALUATING THE QUALITY OF THE MATERIAL AND EQUIPMENT TO BE PROVIDED. G. TESTING AND PLACING IN SERVICE 1. ANY MATERIAL OR EQUIPMENT FAILING A TEST SHALL BE REPAIRED OR REPLACED AT THE CONTRACTOR'S EXPENSE 2. TESTS SHALL INCLUDE THE FOLLOWING: A. MEASURE THE LOAD ON EACH PHASE OF THE MAIN SERVICE AND EACH PHASE OF EVERY FEEDER UNDER FULL LOAD CONDIONS. B. MEASURE THE NO -LOAD AND FULL-LOAD VOLTAGES (PHASE TO PHASE, PHASE TO NEUTRAL AND PHASE TO GROUND FOR EACH PHASE OF EACH SERVICE, OF EACH SEPARATELY DERIVED SYSTEM, AND AT EACH PANELBOARD OR TRANSFORMER). C. MEASURE THE GROUND RESISTANCE OF THE MAIN SERVICE GROUNDING ELECTRODE AND THE GROUND RESISTANCE OF EACH SEPARATELY DERIVED SYSTEM'S GROUNDING ELECTRODE. D. MAKE INSULATION RESISTANCE I ES I S ON ALL DRY TYPE TRANSFORMERS AND MOTORS. H. INTERFERENCES 1. BEFORE THE INSTALLATION OF ANY ITEM BEGINS, THE ELECTRICAL CONTRACTOR SHALL CAREFULLY ASCERTAIN THAT IT DOES NOT INTERFERE WITH CLEARANCES FOR THE ERECTION OF FINISH BEAMS, COLUMNS, PILASTERS, WALLS OR OTHER STRUCTURAL OR ARCHITECTURAL MEMBERS AS SHOWN ON THE ARCHITECTURAL DRAWINGS. IF ANY WORK IS INSTALLED AND THE ARCHITECTURAL DESIGN CANNOT BE FOLLOWED, THIS CONTRACTOR SHALL, AT HIS OWN EXPENSE, MAKE CHANGES IN HIS WORK AS DIRECTED BY NE ARCHITECT TO PERMIT THE COMPLETION OF THE ARCHITECTURAL WORK IN ACCORDANCE WITH DRAWINGS AND SPECIFICATIONS. 2. IT SHALL BE THE DUTY OF THIS CONTRACTOR TO REPORT ANY INTERFERENCES BETWEEN HIS WORK AND THAT OF ANY OF THE OTHER CONTRACTORS AS SOON AS THEY ARE DISCOVERED. THE ARCHITECT SHALL DETERMINE WHICH EQUIPMENT WILL BE RELOCATED, REGARDLESS OF WHICH WAS INSTALLED FIRST. HIS DECISION WILL BE FINAL I. QUALITY ASSURANCE 1. ALL PRODUCTS SHALL BE NEW AND OF NE TYPE AND QUALITY SPECIFIED. WHERE MATERIALS, EQUIPMENT, APPARATUS OR OTHER PRODUCTS ARE SPECIFIED BY MANUFACTURER, BRAND NAME, TYPE OF CATALOG NUMBER, SUCH DESIGNATION SHALL ESTABLISH THE STANDARDS OF THE DESIRED QUALITY AND STYLE. IT IS THE INTENT OF THESE SPECIFICATIONS TO ESTABLISH A STANDARD OF QUALITY OF MATERIALS AND EQUIPMENT INSTALLED. SECTION 16050 - BASIC ELECTRICAL MATERIALS AND _METHODS A. NAMEPLATES 1. GENERAL: FURNISH AND MOUNT ON EACH PANELBOARD, SWITCHBOARD (INCLUDING BRANCH SWITCHES), LARGE JUNCTION BOX, SAFETY SWITCH, STARTER, REMOTE CONTROL, PUSH BUTTON STATION, AND ALL SIMILAR CONTROLS, A NAMEPLATE DESCRIPTIVE OF THE EQUIPMENT OR EQUIPMENT CONTROLLED. 2. PROVIDE BLACK AND WHITE NAMEPLATES CONSTRUCTED FROM LAMINATED PHENOUC WITH A WHITE CENTER CORE LETTERS SHALL BE ENGRAVED IN THE PHENOLIC TO FORM WHITE LETTERS 3/8' HIGH. FASTEN THE NAMEPLATES WITH AN ADHESIVE TYPE FASTENER. PROVIDE 1/8" THICK PLASTIC, BLACK ON WHITE NAMEPLATE WITH ETCHED LETTERS FOR MAIN TENANT DISCONNECT SWITCH IN LANDLORD'S ELECTRIC ROOM. NAMEPLATE SHALL BE PERMANENTLY AFFIXED AND INCLUDE THE TENANT NAME AND SPACE NUMBER. B. MOUNTING ACCESSORIES 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL ANGLE IRON, CHANNEL IRON, RODS, SUPPORTS, HANGERS, CONCRETE OR PLYWOOD REQUIRED TO INSTALL, MOUNT AND SUPPORT ANY ELECTRICAL EQUIPMENT OR DEVICE CALLED FOR ON THE PLANS. 2. SUPPORTING MATERIAL SHALL BE COMPLETE WITH HANGERS, CONNECTORS, BOLTS, CLAMPS AND NECESSARY ACCESSORIES TO MAKE A COMPLETE INSTALLATION. SUPPORTING MATERIAL SHALL BE GALVANIZED, PAINTED OR OTHERWISE SUITABLY L FINISHED. PRODUCTS BY BINKLEY, STEEL CITY OR RACO WILL BE ACCEPTABLE. NO ATTACHMENT OR SUPPORT FROM THE ROOF DECK IS PERMITTED. ALL ATTACHMENTS OR SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. 3. ALL SURFACE - MOUNTED EQUIPMENT ON BLOCK WALLS SHALL BE MOUNTED ON 3/4' PLYWOOD BACKBOARD. ALL FLOOR - MOUNTED EQUIPMENT SHALL BE INSTALLED ON A 4' HIGH CONCRETE HOUSEKEEPING PAD. C. EXECUTION 1. THE ELECTRICAL WORK FOR CONSTRUCTION PROPOSED SHALL CONFORM TO ALL FEDERAL (OSHA), STATE, ALL SPECIFIC SAFETY REQUIREMENTS AND THE REQUIREMENTS OF THE CURRENT EDMON OF THE NEC. 2. CHECK THE HVAC AND PLUMBING SPECIFICATIONS FOR ELECTRICAL REQUIREMENTS AND INCLUDE THE SAME IN THE CONTRACT COST. 3. EQUIPMENT CONNECTIONS, STARTERS, DISCONNECT SWITCHES, CONTROL TRANSFORMERS AND PUSHBUTTON STATIONS FOR THE EQUIPMENT FURNISHED BY THE OWNER OR UNDER A SEPARATE CONTRACT SHALL BE INSTALLED AND CONNECTED UNDER THIS DMSION, AS INDICATED ON THE CONTRACT DRAWINGS. 4. ALL CUTTING, PATCHING, EXCAVATING, BACKFIWNG AND CONCRETE WORK RELATED TO THIS CONTRACT WILL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. THIS CONTRACTOR SHALL ASSUME THE RESPONSIBILITY OF PROVIDING THE SLEEVES, CHASES AND OPENINGS NECESSARY FOR THE ELECTRICAL INSTALLATION AND FOR THEIR REPAIR IN AN ACCEPTABLE MANNER, AS DETERMINED BY THE ARCHITECT. ALL HOLES SHALL BE CORE - DRILLED. PROVIDE FIRE STOP IN ALL OPENINGS CREATED THROUGH FIRE -RATED WALLS, FLOORS OR CEILINGS. 5. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL REQUIRED ACCESS PANELS NECESSARY FOR HIS WORK, COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION. D. MATERIALS AND WORKMANSHIP 1. ALL WORK SHALL BE INSTALLED IN A PRACTICAL AND WORKMANLIKE MANNER, BY MECHANICS SKILLED IN THE SEVERAL TRADES FECESSARY. 2. ALL MATERIALS SHALL BE NEW AND FREE FROM DEFECTS AND SHALL BE THE BEST OF THEIR SEVERAL KINDS UNLESS SPECIFIED OR INDICATED ON THE DRAWINGS TO THE CONTRARY. 3. DURING EACH PHASE AND AT THE COMPLETION OF THE CONSTRUCTION, THIS CONTRACTOR SHALL REMOVE ALL DEBRIS AND EXCESS MATERIALS CAUSED BY HIS WORK. HE SHALL LEAVE THE AREA OF OPERATION BROOM CLEAN. 4. ALL ELECTRICAL EQUIPMENT SHALL BEAR THE UNDERWRITERS LABORATORIES LABEL OR ETL LABEL 5. THIS CONTRACTOR SHALL GUARANTEE HIS WORKMANSHIP AND MATERIAL (LAMPS EXCEPTED) FOR A PERIOD OF ONE YEAR FROM THE DATE OF BUILDING OPENING AND LEAVE HIS WORK IN PERFECT ORDER AT THE COMPLETION. SHOULD DEFECTS DEVELOP WITHIN THE GUARANTEE PERIOD, THE CONTRACTOR SHALL, UPON NOTICE OF THE SAME, REMEDY THE DEFECTS AND HAVE AIL DAMAGES TO OTHER WORK OR FURNISHINGS CAUSED BY THE REPAIRS CORRECTED AT HIS EXPENSE TO THE CONDITION BEFORE SUCH DAMAGE. E. SCOPE OF WORK 1. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIAL, STORAGE, UNPACKING AND PLACEMENT; TO INCLUDE BUT NOT BE LIMITED TO, THE FOLLOWING ITEMS: A. EMERGENCY LIGHTING AND POWER. B. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEM INCLUDING ALL PANELS, TRANSFORMERS AND FEEDERS. C. COMPLETE BRANCH CIRCUIT WIRING SYSTEM. D. COMPLETE POWER WIRING FOR ALL AIR CONDFONING EQUIPMENT, PLUMBING SYSTEM, HEATING EQUIPMENT, VENTILATING AND EXHAUST EQUIPMENT. E. COMPLETE LIGHTING FIXTURE INSTALLATION, INCLUDING ALL INCANDESCENT, FLUORESCENT AND HID LAMPS. F. COMPLETE TELEPHONE AND COMMUNICATION CONDUIT AND WIRING SYSTEM INCLUDING BOXES, PLATES, JACKS, ETC., AS SPECIFIED, SHOWN ON THE DRAWINGS AND REQUIRED BY THE LOCAL TELEPHONE COMPANY AND /OR OWNER. G. TEMPORARY ELECTRICAL POWER AND LIGHTING AS REQUIRED FOR CONSTRUCTION. H. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. I. EXIT LIGHT SYSTEM. J. WIRING DEVICES AND FLOOR BOXES. K. LIGHTING CONTROLS. L GROUNDING OF THE ELECTRICAL SYSTEM. M. SOUND SYSTEM COMPONENTS. N. SUPERVISORY ALARM SYSTEM. F. TEMPORARY SERVICE 1. THE ELECTRICAL CONTRACTOR SHALL FURNISH, INSTALL AND REMOVE AS REQUIRED ALL TEMPORARY POWER AND TEMPORARY LIGHTING IN ALL AREAS AND INDMDUAL ROOMS WHEN NEEDED BY THE INDMDUAL TRADES IN THE PERFORMANCE OF THEIR WORK. THIS CONTRACTOR SHALL PROVIDE A MINIMUM OF TWENTY (20) FOOTCANDLES OF ILLUMINATION FOR TEMPORARY LIGHTING. ANY ADDITIONAL LIGHTING REQUIRED BY INDMDUAL TRADES SHALL BE PROVIDED BY THE INDMDUAL TRADES INCLUDING POWER FOR THE LIGHTING. THE ELECTRICAL WORK FOR CONSTRUCTION PURPOSES SHALL CONFORM TO ALL FEDERAL (OSHA), STATE, SPECIFIC SAFETY REQUIREMENTS, AS WELL AS THE REQUIREMENTS OF THE NATIONAL ELECTRIC CODE AND NATIONAL ELECTRICAL SAFETY CODE. THE ELECTRICAL CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED APPLICATIONS, PERMITS AND INSPECTIONS PERTAINING TO THIS WORK. THIS COST SHALL BE INCLUDED IN THE CONTRACTOR'S PRICE. 2. NEW LIGHT FIXTURES SHALL NOT BE USED FOR TEMPORARY LIGHTING. EC. SHALL UTILIZE LL FURNISHED DISCONNECT SWITCH WITHIN TENANT SPACE FOR TEMPORARY ELECTRIC SERVICE EC. SHALL PROVIDE TRANSFORMERS AND PANELS AS REQUIRED. EC. SHALL RELOCATE DISCONNECT SWITCH TO TENANT E LEC ROOM ONCE PERMANENT SERVICE IS AVAILABLE TO BE USED. SECTION 16060 - GROUNDING AND BONDING A. GROUND ALL EQUIPMENT PER N.EC. B. GROUND ALL DRY TYPE TRANSFORMERS AS PER DRAWINGS AND NEC #450 -10. C. ALL CONDUITS SHALL CONTAIN A CODE -SIZED GROUND WIRE SIZE PER N.E.C. IN ADDEON TO THE CONDUCTORS SHOWN ON THE PLANS. WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE FOR VOLTAGE DROP, THE GROUND WIRE SIZE SHALL BE INCREASED PROPOR11ONATELY. D. WHERE AN ISOLATED, INSULATED GROUND IS REQUIRED A SEPARATE ISOLATED GREEN GROUND SHALL BE RUN FROM THE PANEL ISOLATED GROUND BUS TO THE ISOLATED GROUND CONNECTION OF THE DEVICE SERVED. IN NO CASE SHALL THE SYSTEM GROUND (GREEN WIRE AND ASSOCIATED OUTLET BOXES, CONDUIT AND BUILDING STEEL) BE ALLOWED TO CONTACT THE ISOLATED GROUND (GREEN WIRE WITH WHITE STRIPE). SECTION 16120 - WIRE AND CABLE A. COLOR CODE CONDUCTORS (EXCEPT CONTROL AND INSTRUMENTATION CONDUCTORS) AS FOLLOWS: 208/120 SYSTEM PHASE A PHASE B PHASE C NEUTRAL GROUND BLACK RED BLUE WHITE GREEN 480/277 SYSTEM BROWN ORANGE YELLOW GREY GREEN 1. 112 AND #10 CONDUCTORS SHALL HAVE CONTINUOUS INSULATION COLOR, AS LISTED ABOVE. 2. COLOR CODE CONDUCTORS LARGER THAN ABOVE, WHICH DO NOT HAVE CONTINUOUS INSULATION COLOR BY APPLICATION OF AT LEAST TWO LAPS OF COLORED TAPE ON EACH CONDUCTOR AT ALL POINTS OF ACCESS INCLUDING JUNCTION BOXES. COLOR TAPE SHALL BE THE EQUAL OF 3M PRODUCTS SCOTCH 135. 3. CONDUCTORS SHALL BE SOFT ANNEALED COPPER INSULATED FOR 600 VOLTS UNLESS SPECIFICALLY INDICATED OTHERWISE ALUMINUM CONDUCTORS ARE NOT ALLOWED ON THIS PROJECT. B. INSULATION TYPE SHALL BE TYPE THW FOR WIRE SIZES 8 AWG AND LARGER AND THHN OR THWN FOR #10 AWG AND SMALLER. THHN SHALL NOT BE USED IN WET OR DAMP LOCATIONS. C. D. F. G. H. FLEXIBLE CORD SHALL BE HEAVY DUTY TYPE SO WFM AN EQUIPMENT GROUND CONDUCTOR IN ADDITION TO THE CURRENT CARRYING CONDUCTORS. PROVIDE #12 CONDUCTORS, UNLESS OTHERWISE INDICATED. 1. CONTROL CONDUCTORS SHALL BE #14 MINIMUM FOR NEC CLASS I AND #16 FOR NEC CLASSII. CONDUCTORS j8 AWG AND LARGER SHALL BE STRANDED. CONDUCTORS #10 AWG AND SMALLER SHALL BE SOLID. INSTALL WIRING IN CONDUIT. CONNECT 110 AND SMALLER WIRES WITH CONSTANT PRESSURE EXPANDABLE SPRING TYPE CONNECTORS, 'SCOTCHLOK' BY 3M OR B -CAP BY BUCHANAN. I. CONNECT #8 AND LARGER WIRES WITH COMPRESSION CONNECTORS OR SPLICES AS MANUFACTURED BY BURNDY OR T &B. J. INSULATE SPLICING CONNECTORS TO AT LEAST 200% OF THE WIRE INSULATION. USE PRE - STRETCHED TUBING CONNECTOR INSULATORS, 3M PST FOR #2 AND LARGER CONDUCTORS. K. PULL CONDUCTORS USING RECOGNIZED METHODS AND EQUIPMENT LEAVING AT LEAST 6' WIRE AT ALL JUNCTION BOXES FOR CONNECTIONS. 1. CLEANOUT EACH CONDUIT SYSTEM BEFORE PUWNG WIRE. L FORM AND TIE ALL WIRING IN PANELBOARDS. M. THERE SHALL BE NO WIRENUT JOINTS OR SPLICES MADE INSIDE SWITCHBOARDS / PANELBOARDS. N. BRANCH CIRCUIT WIRE SIZES (AND CONDUITS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PLANS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES NOT EXCEED LIMIT OF 3 %. 0. WIRE SIZES SHALL BE BASED ON THE 60 DEGREES C. AMPACMES FOR WIRE SIZES NO. 14 -1 A.W.G., AND 75 DEGREES C. AMPACMES FOR WIRE SIZES 11/0 A.W.G. AND LARGER. P. CIRCUITS MAY BE MUL11- PLEXED IN CONDUIT PROVIDED WIRE IS PROPERLY DERATED AND CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN (9) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONDUIT. Q. PROVIDE WIRE AND RACEWAY SYSTEMS AS DESCRIBED HEREIN AND INDICATED ON THE DRAWINGS. METAL -CLAD (MC), AND NON- METAWC SHEATED CABLE (NMC) SHALL NOT BE PERMITTED. UNLESS NOTED SPECIFICALLY OTHERWISE AND APPROVED PRIOR TO BIDDING. ARMORED CABLE (AC). BX AND ROME( WIRING IS NOT PERMITTED SECTION 16130 - RACEWAYS AND BOXES A. RACEWAYS 1. ALL WIRE SHALL BE RUN IN ACCORDANCE WITH CODE IN CORROSION RESISTANT, RIGID, THREADED, METAL CONDUIT OR ELECTRICAL METAWC TUBING (EM.T.) UNLESS OTHERWISE SPECIFICALLY STATED HEREIN. A CONDUIT IN EXTERIOR WALLS, BELOW FLOOR SLAB, OR UNDERGROUND SHALL BE RIGID, THREADED, GALVANIZED, HEAVY WALL TYPE B. CARLON PVC TYPE 40 HEAVY WALL CONDUIT WITH GROUND WIRE MAY BE USED BELOW FLOOR SLAB OR UNDERGROUND IN LIEU OF RIGID, THREADED, GALVANIZED CONDUIT. PVC 40 CONDUIT SHALL NOT BE RUN IN OR ABOVE FLOOR SLAB. PVC CONDUIT SHALL TERMINATE BELOW FLOOR SLAB WITH RIGID, THREADED METAL CONDUIT ADAPTER. CONDUIT ABOVE SLAB SHALL BE METAL C. CONDUIT RUN EXPOSED TO THE WEATHER SHALL BE HEAVY WALL, METAL THREADED TYPE 2. CONDUIT SIZE SHALL BE 3/4' MINIMUM. 3. CONDUIT SHALL BE SECURELY FASTENED IN PLACE 4. ALL CONDUIT SHALL BE CONCEALED IN WALLS, FLOOR AND CEILINGS WHEREVER POSSIBLE. EXPOSED CONDUIT IN FINISHED AREAS WILL NOT BE PERMITTED. EXPOSED CONDUIT WILL BE PERMITTED IN UNFINISHED AREAS WITH THE SPECIFIC APPROVAL OF THE ARCHITECT. 5. USE FLEXIBLE CONDUIT FOR THE CONNECTION TO RECESSED OR SEMI - RECESSED LIGHTING FIXTURES (6' LENGTH MAXIMUM). USE LIQUID TIGHT METAL CONDUFF FOR ALL CONNECTIONS TO MOTORS AND OTHER EQUIPMENT SUBJECT TO VIBRATION AND IN AREAS SUBJECT TO MOISTURE. 6. USE WATERTIGHT JOINTS WITH BURIED AND CONCRETE ENCASED CONDUIT. ALL BURIED CONDUITS OUTSIDE OF BUILDINGS SHALL HAVE A MINIMUM OF 24" OF COVER. METAL CONDUITS BURIED IN EARTH SHALL BE PAINTED (TWO COATS) WITH HEAVY ASPHALTUM PAINT. 7. SUPPORT RUNS OF CONDUIT AS DETAILED IN THE APPROPRIATE TABLE OF THE NATIONAL ELECTRICAL CODE (NEC). 8. INSTALL EXPOSED RUNS OF CONDUIT AND CONDUIT ABOVE LAY -IN CEILINGS PARALLEL. OR PERPENDICULAR TO THE WALLS, STRUCTURAL MEMBERS OF INTERSECTIONS OF VERTICAL PLANES AND CEILINGS. PROVIDE RIGHT ANGLE TURNS USING FITTINGS OR SYMMETRICAL BENDS. SUPPORT CONDUITS WITHIN 1' OF ALL CHANGES IN DIRECTION. 9. IF A CONDUIT IS SUSPENDED, IT SHALL BE SUPPORTED ON TRAPEZE HANGERS WHICH USE "ALL- THREAD' RODS FROM THE STRUCTURAL STEEL THE USE OF CEILING SUPPORT WIRE OR SIMILAR MATERIAL WILL NOT BE ACCEPTED. 10. INSTALL EMPTY CONDUIT FOR FUTURE USE AS INDICATED ON THE DRAWINGS, CONDUIT SHALL BE COMPLETE WITH JETIJNE OR PULL ROPE, JUNCTION /OUTLET BOXES, TILE RINGS AND APPROPRIATE COVER PLATES. 11. PROVIDE PITCHPOCKETS WHERE CONDUITS PENETRATE THE ROOF. 12. THREAD LUBRICATION /SEALANT I5 REQUIRED ON OUTDOOR AND UNDERGROUND THREADED METAL JOINTS. 13. INSTALL FIRE SEAL FITTINGS WHERE CONDUITS PENETRATE CONCRETE FLOOR SLABS OR MASONRY WALLS REQUIRED TO BE FIRE RATED. 14. HORIZONTAL PORTION OF CONDUIT EXPOSED ON THE ROOF AND FEEDING EQUIPMENT SHALL NOT BE MORE THAN 5' -O" UNLESS THE WRITTEN APPROVAL FROM ARCHITECT OR ENGINEER IS OBTAINED. C. SECII 4. PROVIDE CONCRETE BOXES FOR UNDERGROUND WORK UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FURNISH STEEL FRAMES AND COVERS WITH THE COVER ATTACHED TO NE FRAME WITH HEXAGON HEAD, BRASS OR BRONZE CAP SCREWS, 3/8' IN. DIAMETER. PROVIDE A RUBBER GASKET FOR SEALING BETWEEN THE COVER AND THE FRAME PAINT THE COVER WITH TWO COATS OF HEAVY ASPHALTUM. OUTLET BOXES 1. USE SHEET STEEL BOXES, ZINC COATED OR CADMIUM PLATED, FOR CONCEALED INTERIOR WORK. 2. USE CAST BOXES, ZINC- CADMIUM FINISH MALLEABLE IRON, FOR EXPOSED INTERIOR WORK, AND FOR EXPOSED OR CONCEALED WORK IN WET, DAMP OR EXTERIOR LOCATIONS. CAST BOXES SHALL BE SERIES FD BY CROUSE HINDS OR APPLETON. 3. WALL BOX SIZES (MINIMUM) SHALL BE 4' SQUARE X 2 -1/2' DEEP WHERE WALL CONSTRUCTION PERMITS. WHERE WALL CONSTRUCTION DICTATES, THE WIDTH MAY BE REDUCED TO 2 -1/8' OR 1 -1/2' UNDER SPECIAL CONDITIONS. 4. FIXTURE OUTLETS IN CEILINGS (MINIMUM) SHALL BE 4' OCTAGONAL X 1 -1/2' DEEP (4- 11/16' OCTAGONAL X 2 -1/2' DEEP WHERE REQUIRED TO ACCOMMODATE LARGER CONDUIT OR LARGER NUMBER OF WIRES). 5. GANG BOXES SHALL BE ONE PIECE (MINIMUM), 2- 1/8' DEEP. 6. PROVIDE FLUSH FLOOR BOX SERIES 880 BY WIREMOLD WITH DUPLEX RECEPTACLE FOR WOOD PLATFORM AT DISPLAY SHOW WINDOWS, BOX WITH COVERPLATE FLANGE: CAT. #880W1- 818TCAL AND BRUSHED ALUMINUM COVERPLATE: CAT. 1828R -TCAL WITH FLIP LID TO PROTECT RECEPTACLE WHEN NOT IN USE BOTH FLANGE AND COVERPLATE SHALL HAVE BRUSHED ALUMINUM FINISH. UL SCRUB LISTED. 7. PROVIDE SPECIFICATION 16130.C.6 AS ON THE EXAMPLE JOB. 8. FLUSH MOUNT BOXES IN ALL FINISHED WALLS, INSTALL THE PLASTER RINGS IN DRYWALLED PLASTERED WALLS AND RAISED COVERS AS REQUIRED IN WALLS WITH OTHER FINISHES SO THAT THE COVER PLATES FIT TIGHTLY AGAINST BOXES OR RINGS, 3/16' MAXIMUM GAPS ARE ALLOWED FOR NONCOMBUSTIBLE WALLS. 9. ADJUST LOCATION OF OUTLETS IN MASONRY OR 11LE CONSTRUCTION TO OCCUR IN THE NEAREST JOINT TO THE HEIGHT SPECIFIED. HEIGHTS SHALL MEET ADA REQUIREMENTS. 10. SUPPORT ALL BOXES TO MAINTAIN PROPER ALIGNMENT AND RIGIDITY. 11. CLEAN BOXES OF ALL FOREIGN MATTER PRIOR TO THE INSTALLATION OR WIRING OF DEVICES. 12. MOUNTING HEIGHTS ON THE DRAWINGS ARE TO THE CENTERLINE OF THE BOX UNLESS OTHERWISE NOTED. ON 16140 - WIRING DEVICES A. WIRING DEVICE COLOR SHALL BE SELECTED BY ARCHITECT, UNLESS OTHERWISE INDICATED. B. C. D. PROVIDE TOTALLY ENCLOSED, 20 AMPERE, 120/277 VOLT, QUIET A/C GENERAL USE SNAP SWITCHES. SWITCHES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL P&S, OR LEVITON. PROVIDE NEMA CONFIGURATION 5 -20R DUPLEX 125 VOLT GROUNDING TYPE RECEPTACLES RATED FOR 20 AMPERES UNLESS OTHERWISE INDICATED ON THE DRAWINGS. E. RECEPTACLES SHALL BE SPECIFICATION GRADE AS MANUFACTURED BY HUBBELL, P&S OR LEMON. F. G. RECEPTACLES REQUIRING AMPERAGES, VOLTAGES OR CONFIGURATIONS DIFFERENT FROM THE DUPLEX CONVENIENCE RECEPTACLES ABOVE SHALL BE AS INDICATED ON THE DRAWINGS. PROVIDE OTHER RECEPTACLES OF A QUALITY, MATERIAL AND WORKMANSHIP EQUAL TO THAT SPECIFIED FOR DUPLEX CONVENIENCE RECEPTACLES. PROVIDE COVER OR DEVICE PLATES FOR OUTLET BOXES AS FOLLOWS UNLESS OTHERWISE NOTED: 1. FINISHED AREAS: THERMOPLASTIC - COLOR TO MATCH DEVICE. 2. UNFINISHED AREAS: ZINC COATED SHEET METAL, ALUMINUM, OR CAST METAL AS APPROPRIATE FOR THE TYPE OF BOX. TELEPHONE, COMMUNICATION, AND SIGNAL OUTLET PLATES, SHALL MATCH THOSE USED FOR RECEPTACLES AND SWITCHES. ALL OUTLET AND /OR JUNCTION BOXES SHALL BE COMPLETE WITH A COVER PLATE BY THIS CONTRACTOR. WHERE DEVICES ARE GANGED, THEY SHALL BE INSTALLED UNDER A COMMON COVERPLATE. B. PULL AND JUNCTION BOXES 1. INSTALL PULL AND JUNCTION BOXES WHERE SHOWN ON THE DRAWINGS, AND WHERE REQUIRED FOR CHANGES IN DIRECTION, AT JUNCTION POINTS, AND TO FACILITATE WIRE PUWNG. FURNISH BOX SIZES IN ACCORDANCE WITH NEC UNLESS LARGER BOXES ARE INDICATED. 2. PROVIDE STEEL BOXES AND REMOVABLE COVERS OF CODE GAGE, HOT ROLLED SHEET STEEL, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE, FOR ABOVE GROUND WORK. FURNISH WEATHERPROOF BOXES WHEN INSTALLED ABOVE GROUND OUTSIDE. 3. PROVIDE CAST IRON BOXES, HOT DIPPED GALVANIZED INSIDE AND OUTSIDE WHERE SHOWN ON THE DRAWINGS. FURNISH REMOVABLE COVERS WITH GASKETS AND STAINLESS STEEL, BRASS OR BRONZE SCREWS. RECE VEt APR 16 2008 PERMIT CENTEIz I. LOCATE THE SWITCHES APPROXIMATELY 4' -0' ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN A.DA REQUIREMENTS), UNLESS OTHERWISE INDICATED. THE LONG DIMENSION OF THE SWITCHES SHALL BE VERTICAL J. LOCATE RECEPTACLES APPROXIMATELY 1' -6' ABOVE THE FINISHED FLOOR ELEVATION OR NEAREST BLOCK COURSE (WITHIN ADA REQUIREMENTS), UNLESS NOTED OTHERWISE. THE LONG DIMENSION OF RECEPTACLES SHALL BE VERTICAL SECTION 16410 - SAFETY SWITCHES A. SAFETY SWITCHES SHALL BE THE ENCLOSED HEAVY -DUTY TYPE (TYPE HD) WITH QUICK -MAKE, QUICK -BREAK MECHANISM AND EXTERNAL PAD LOCKABLE OPERATING HANDLE. B. SAFETY SWITCHES SHALL BE RATED FOR 240 OR 600 VOLTS AS APPLICABLE THEY SHALL BE HORSEPOWER RATED WHEN USED IN MOTOR CIRCUITS. C. SAFETY SWITCHES SHALL BE FUSIBLE OR NON- FUSIBLE 2, 3, OR 4 POLE AS INDICATED ON THE DRAWINGS. D. SAFETY SWITCHES SHALL BE SINGLE THROW UNLESS OTHERWISE INDICATED ON THE DRAWINGS. E. ENCLOSURES SHALL BE NEMA 1 INDOORS AND NEMA 3R OUTDOORS UNLESS OTHERWISE INDICATED ON DRAWINGS. F. MANUFACTURER SHALL BE SQUARE D, SIEMENS, G.E, OR CUTLER - HAMMER. ALL SAFETY SWITCHES SHALL BE BY ONE MANUFACTURER. G. MOUNT THE SAFETY SWITCHES SECURELY BETWEEN 3' X 6' LEVELS ABOVE THE FLOOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. H. SWITCHES ON BLOCK WALLS SHALL BE MOUNTED ON A 3/4" PLYWOOD BACKBOARD, WHERE LOCATED INDOORS. US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA WASHINGTON 98188 EXPIRES EXPIRES SEP 032009 ■■ THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West Streetsboro Road Richfield. Ohio 44286 (330) 659 -6688 Ph. (330) 659 -6675 Fax QAQC No. Date 02/06/08 03/07/08 A 03/19/08 Issue DESIGN DEVELOPMENT PERMIT, LANDLORD, BID ADDENDUM B Project No. Scale DravnBy: 43328 AS NOTED JDM Y:\2008\20013-0049\CadWeA2008-0049E5-1.dwg Droving No. ELECTRICAL SPECIFICATIONS E5.1 MA Dwg Name: 2008- 0049E5 -3.dwg Scale: 1' =1' -0° Date: Apr. 14, 2008 lime: 1:26 pm Plotted Monday April 14, 2008 1:26pm by gsimon B. REFER TO H &M SUPPLIED "US /CA STANDARD STORE IT DEPARTMENT SPECIFICATIONS", VERSION 6.0, UPDATED 07 FEBRUARY, 2007 FOR ADDMONAL INFORMATION FOR COORDINATION. C. TECHNOLOGY CONTRACTOR SHALL COORDINATE INSTALLATION OF HIGH -SPEED DATA CONNECTION WITH SERVICE PROVIDER TO ALLOW ALL EQUIPMENT TO BE INSTALLED IN TENANT SPACE. D. TECHNOLOGY CONTRACTOR WILL MAKE ALL CROSS CONNECTIONS NEEDED TO EXTEND THE DATA CONNECTION FROM THE BUILDING DEMARK TO TENANT DEMARK BEFORE INSTALLATION OF HIGH -SPEED DATA SERVICE. TELEPHONE/DATA CONDUIT SYSTEM 1. ELECTRICAL CONTRACTOR TO PROVIDE TELEPHONE SERVICE CONDUIT OR DUCT TO TELEPHONE BOARD AS SHOWN ON PLANS. CONDUIT SHALL BE RIGID OR E.M.T.. FLEX OR GREENFIELD IS NOT PERMITTED. THERE SHALL BE EASY ACCESS TO ALL PULL BOX LOCATIONS IF THERE ARE MORE THAN 3 BENDS. EC. MUST NOTIFY THE TC IN WRmNG, THE EXACT LENGTH OF THE CONDUIT, HOW MANY BENDS THERE ARE, PROVIDE THEM WITH A MAP OF THE BENDS. EC. MUST VERIFY WITH MALL AND LOCAL TELCO PROVIDER WHICH TELEPHONE ROOM LOCATION TO RUN THE CONDUIT FROM TO H &M'S SPACE. THE ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUIT AND OUTLET BOXES FOR TECHNOLOGY CABLING. THE TECHNOLOGY CONTRACTOR SHALL PROVIDE AND INSTALL ALL 25 PAIR AND CAT5E CABLE, DATA AND PHONE JACKS, FACE PLATES, PATCH PANELS, TECHNOLOGY CABINET AND MISCELLANEOUS EQUIPMENT TO MEET THE SPECIFICATIONS. • EC. SHALL PROVIDE PLYWOOD TERMINAL BOARD AS SHOWN ON DRAWINGS. . A CONDUIT RUN SHALL HAVE NO MORE THAN THREE (3) BENDS IN A RUN BETWEEN OUTLET BOXES OR BETWEEN OUTLET BOX AND A METAL CABINET OR PULL BOX. WHEN A RUN REQUIRES MORE THAN THREE (3) BENDS, A PULL BOX OF SUITABLE SIZE SHALL BE PLACED IN A SUITABLE LOCATION TO MEET THE ABOVE CONDmONS. DAISY CHAINING OR BENDING BEHIND WALLS IS )8SOLUTELEY NOT PERMITTED. . ALL TELEPHONE AND DATA CABLING SHALL BE IN CONDUIT CONDUIT SHALL BE CONTINUOUS FROM DEVICE TO DATA RACK IN ELECTRICAL ROOM. CONDUIT SHALL MEET FILL REQUIREMENTS AS INDICATED IN THE TABLE AT THE END OF THE SPECIFICATIONS. PULL- STRINGS MUST BE PLACED IN ALL CONDUIT BY EC. AND T.C. MUST RUN NEW PULL- STRINGS THROUGH CONDUIT ALONG WITH CABLES FOR FUTURE EXPANSION CAPABILITIES. MANUFACTURERS 1. APPROVED MANUFACTURERS: A. CABLE 1) BELDEN WIRE & CABLE COMPANY (317- 983- 5200). 2) ESSEX GROUP, INC.; TELECOMMUNICATIONS PRODUCTS DMSION (214- 461 - 4000). 3) GENERAL CABLE (908 - 769 - 3200). 4) MOHAWK /CDT (800- 422 - 9661). B. TERMINAL AND CONNECTOR COMPONENTS AND PATCH PANELS. 1) LEVITON TELECOM (800 - 323 -8920) ONLY. NO SUBSTITUTIONS PERMITTED. SYSTEM REQUIREMENTS 1. GENERAL COORDINATE THE FEATURES OF MATERIALS AND EQUIPMENT SO THEY FORM AN INTEGRATED SYSTEM. MATCH COMPONENTS AND INTERCONNECTIONS FOR OPTIMUM FUTURE PERFORMANCE. 2 EXPANSION CAPABILITY: UNLESS OTHERWISE INDICATED, PROVIDE CONDUCTOR PAIRS IN CABLES, POSmONS IN PATCH PANELS, CROSS CONNECTS, AND TERMINAL STRIPS, AND SPACE IN BACKBONE CABLE TRAYS AND WIREWAYS TO ACCOMMODATE 50 PERCENT FUTURE INCREASE IN ACTIVE STATION PAIRS. MOUNTING ELEMENTS 1. BACKBOARDS: 3/4 -INCH INTERIOR- GRADE, FIRE - RESISTIVE- TREATED PLYWOOD. 2. DISTRIBUTION RACKS: FLOOR- STANDING, MODULAR - STEEL UNIT, ENCLOSED WITH DOOR. DESIGNED FOR TELECOMMUNICATIONS TERMINAL SUPPORT AND COORDINATED WITH DIMENSIONS OF UNITS TO BE SUPPORTED. A. ENCLOSED CABINET WITH FLUSH PLEXI DOOR LOUVERED REAR DOOR, SOLID SIDE PANELS, AND 19" PANEL RAILS. GREAT LAKES EQUIPMENT CATALOG #GL720E -2936L WITH TPE- 29L LOUVERED TOP. NO SUBSTITUTIONS PERMITTED PROVIDE UNIT WITH THE FOLLOWING ACCESSORIES: #7215 -20ART - RACK MOUNT POWER BAR 7206 -FR -ADHD -- 19" FIXED WIDE RACK MOUNT SELF (3 REQUIRED) IVLB -7236 - HIGH VERTICAL CABLE MANAGER KIT 3. FINISH: BAKED - POLYESTER POWDER COAT. TWISTED -PAIR CABLES, CONNECTORS, AND TERMINAL EQUIPMENT 1. LISTED AS COMPLYING WITH CATEGORIES 5 OF EIA/TIA- 568 -B. DATA ABND TELEPHONE BRANCH CABLE SHALL BE CATEGORY 5e. . CONDUCTORS: SOLID COPPER. . UTP CABLE: COMPLY WITH EIA/T1A- 568 -B. FOUR THERMOPLASTIC- INSULATED, INDMDUALLY TWISTED PAIRS OF CONDUCTORS; NO. 24 AWG, COLOR -CODED; ENCLOSED IN PVC JACKET, UTP CABLE CONNECTING HARDWARE COMPLY WITH QA/IIA- 568 -B. IDC TYPE, USING MODULES DESIGNED FOR PUNCH -DOWN CAPS OR TOOLS. A. IDC TERMINAL BLOCK MODULES: INTEGRAL WITH CONNECTOR BODIES, INCLUDING PLUGS AND JACKS WHERE INDICATED. B. IDC CONNECTING HARDWARE: CONSISTENT THROUGHOUT PROJECT. 5 PATCH PANELS: MODULAR PANELS HOUSING MULTIPLE, NUMBERED JACK UNITS WITH IDC -TYPE CONNECTORS AT EACH JACK FOR PERMANENT TERMINATION OF PAIR GROUPS OF INSTALLED CABLES. A. NUMBER OF PORTS PER FIELD: 1) PATCH PANEL 'A' SHOULD BE IN TWO PARTS (1) 48 PORT PANEL, LEVITON #5G596 -U48, AND (1) 24 PORT PANEL, LEVITON •5G596 -U24, AND PATCH PANEL "B' SHOULD BE A 24 PORT PANEL IN STORES WITH 12 OR LESS CASH REGISTERS. IF THE STORE HAS MORE THAN 12 REGISTERS, PATCH PANEL "A" SHOULD BE (2) 48 PORT PANELS. IF THE STORE HAS 24 OR MORE REGISTERS PATCH PANEL "A" SHOULD BE IN THREE PARTS (2) 48 PORT PANELS AND (1) 24 PORT PANEL PLUS ONE ADDMONAL WIRE MANAGEMENT RACK, IN ALL CASE PATCH PANEL 'B' WILL BE A 24 PORT PANEL B. MOUNTING: CABINET. 6. JACKS AND JACK ASSEMBLIES FOR DATA CIRCUIT UTP CABLE: MODULAR, COLOR - CODED, RJ -45 RECEPTACLE UNITS WITH INTEGRAL IDC -TYPE TERMINALS. A. 1 PORT JACK LOCATION, (1) LEVITON #41108 - RV5 W /LEVITON #42080 -1WS WAIL PLATE. B. 2 PORT JACK LOCA11ON, (2) LEVITON #41108 - RV5 W /LEVITON #42080 -2WS. C. 4 PORT JACK LOCATION (4) LEVITON #41108 - RV5 W /LEVITON #42080 -4WS WALL PLATE. D. 6 PORT JACK LOCATION, (6) LEVITON #41108 - RV5 W /LEVITON #42080 -6WS WALL PLATE. E. WALL TELEPHONE LOCA11ON: 8 -PIN RJ45, INSIDE ICC PART #ICC- IC107FWP -IV. F. SURFACE BOX FOR DATA PORTS AT CASHWRAPS: (1) LEVITON 42777 -1WA 7. T.C. SHALL SUPPLY 4) WIRE MANAGEMENT RACKS FOR THE DATA RACK. LEVITON #49252 -PCM. REFER TO H &M SUPPLIED "US /CA STANDARD STORE IT DEPARTMENT SPECIFICATIONS", VERSION 6.0, UPDATED 07 FEBRUARY - 2007 FOR ADDITIONAL INFORMATION. J. IDENTIFICATION PRODUCTS 1. CABLE LABELS: SELF - ADHESIVE VINYL OR VINYL -CLOTH WRAPAROUND TAPE MARKERS, MACHINE PRINTED WffH ALPHANUMERIC CABLE DESIGNATIONS. 2. BROTHER P-TOUCH (OR EQUIVALENT) WITH BLACK ON WHITE LABELING. 3. HANDWRITTEN LABELS ARE NOT PERMITTED. K. EXAMINATION 1. EXAMINE PATHWAY ELEMENTS INTENDED FOR CABLE, CHECK RACEWAYS, CABLE TRAYS, AND OTHER ELEMENTS FOR COMPLIANCE WITH SPACE ALLOCATIONS, INSTALLATION TOLERANCES, HAZARDS TO CABLE INSTALLATION, AND OTHER CONDMONS AFFECTING INSTALLATION. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDUONS HAVE BEEN CORRECTED. L APPLICATION OF MEDIA 1. HORIZONTAL CABLES FOR DATA SERVICE USE UTP CABLE COMPLYING WITH CATEGORY 5e OF EIA/TIA- 568-B FOR RUNS BETWEEN WIRING CLOSETS AND WORKSTATION OUTLETS. M. INSTALLATION 1. WIRING METHOD: INSTALL WIRING AS DESCRIBED HEREIN. CONCEAL WIRING EXCEPT IN UNFINISHED SPACES. 2. INSTALL CABLE USING TECHNIQUES, PRACTICES, AND METHODS THAT ARE CONSISTENT WITH CATEGORY 5e RATING OF COMPONENTS AND THAT ENSURE CATEGORY 5e PERFORMANCE OF COMPLETED AND LINKED SIGNAL PATHS, END -TO -END. 3. INSTALL CABLE WITHOUT DAMAGING CONDUCTORS, SHIELD, OR JACKET. 4. DO NOT BEND CABLE IN HANDLING OR IN INSTAWNG TO SMALLER RADII THAN MINIMUMS RECOMMENDED BY MANUFACTURER. 5. PULL CABLES WITHOUT EXCEEDING CABLE MANUFACTURER'S RECOMMENDED PUWNG TENSIONS. A PULL CABLES SIMULTANEOUSLY IF MORE THAN ONE IS BEING INSTALLED IN THE SAME RACEWAY. B. USE PUWNG COMPOUND OR LUBRICANT IF NECESSARY. USE COMPOUNDS THAT WILL NOT DAMAGE CONDUCTOR OR INSULATION. C. USE PUWNG MEANS, INCLUDING FISH TAPE, CABLE, ROPE, AND BASKET -WEAVE WIRE /CABLE GRIPS, THAT WILL NOT DAMAGE MEDIA OR RACEWAY. 6. WIRING WITHIN WIRING CLOSETS AND ENCLOSURES: PROVIDE ADEQUATE LENGTH OF CONDUCTORS. TRAIN CONDUCTORS TO TERMINAL POINTS WITH NO EXCESS. USE LACING BARS TO RESTRAIN CABLES, TO PREVENT STRAINING CONNECTIONS, AND TO PREVENT BENDING CABLES TO SMALLER RADII THAN MINIMUMS RECOMMENDED BY MANUFACTURER. 7. SEPARATION OF WIRES: COMPLY WITH EIA/TIA -569 RULES FOR SEPARATING UNSHIELDED COPPER COMMUNICATION AND DATA - PROCESSING EQUIPMENT CABLES FROM POTENTIAL EMI SOURCES, INCLUDING ELECTRICAL POWER LINES AND EQUIPMENT. 8. MAKE SPLICES, TAPS, AND TERMINATIONS ONLY AT INDICATED OUTLETS, TERMINALS, AND CROSS - CONNECT AND PATCH PANELS. 9. USE SPLICE AND TAP CONNECTORS COMPATIBLE WITH MEDIA TYPES. 10. INSTALL A PULL WIRE IN EACH AND EVERY EMPTY CONDUIT. 11. EACH CABLE SHALL BE TERMINATED AND LABELED WITH THE PORT NUMBER AT PANEL A 12. T.C. SHALL INSTALL A CATEGORY 5 RATED 25-PAIR CABLE FROM THE MALL OR BUILDING PHONE ROOM AND /OR SUB PHONE ROOM TO THE TELEPHONE BACKBOARD IN THE ELECTRICAL ROOM BESIDE THE LAN CABINET, TERMINATED TO A 66 -BLOCK ON BOTH ENDS. N. GROUNDING 1. GROUND CABLE SHIELDS, DRAIN CONDUCTORS, AND EQUIPMENT TO ELIMINATE SHOCK HAZARD AND TO MINIMIZE GROUND LOOPS, COMMON -MODE RETURNS, NOISE PICK -UP, CROSS TALK, AND OTHER IMPAIRMENTS. 2. BOND SHIELDS AND DRAIN CONDUCTORS TO GROUND AT ONLY ONE POINT IN EACH CIRCUIT. 3. SIGNAL GROUND TERMINAL LOCATE IN EACH EQUIPMENT ROOM AND WIRING CLOSET. ISOLATE FROM POWER SYSTEM AND EQUIPMENT GROUNDING. 4. SIGNAL GROUND BUS: MOUNT ON WALL OF MAIN EQUIPMENT ROOM WITH STAND -OFF INSULATORS. 5. SIGNAL GROUND BACKBONE CABLE EXTEND FROM SIGNAL GROUND BUS TO SIGNAL GROUND TERMINAL IN EACH WIRING CLOSET AND EQUIPMENT ROOM. 0. INSTALLATION IN EQUIPMENT ROOMS AND CABINETS 1. PROVIDE BACKBOARD AS SHOWN ON THE DRAWINGS. 2. MOUNT PATCH PANED, TERMINAL STRIPS, AND OTHER CONNECTING HARDWARE IN THE SPECIFIED CABINET. 3. GROUP CONNECTING HARDWARE FOR CABLES INTO SEPARATE LOGICAL FIELDS. 4. USE PATCH PANELS TO TERMINATE CABLES ENTERING THE CABINET. P. IDENTIFICATION 1. IDENTIFY SYSTEM COMPONENTS COMPLYING WITH APPLICABLE REQUIREMENTS IN DMSION 16, SECTION 16075, ELECTRICAL IDENTIFICATION AND THE FOLLOWING SPECIFICATIONS. 2. SYSTEM: NUMBER THE PORTS CONSECUTIVELY (E.G., 1, 2, 3...ETC.). 3. WORKSTATION: LABEL CABLE PORT NUMBER ON CABLE SHIELDING WM-IIN THE OUTLET BOX. 4. DISTRIBUTION RACKS AND FRAMES: CONSECUTIVELY LABEL EACH UNIT AND FIELD WIHHIN THAT UNIT. 5. WITHIN CONNECTOR FIELDS, IN WIRING CLOSETS AND EQUIPMENT ROOMS: LABEL EACH CONNECTOR AND EACH DISCRETE UNIT OF CABLE- TERMINAT1NG AND CONNECTING HARDWARE 6. CABLES, GENERAL LABEL EACH CABLE WITHIN 4 INCHES TO EACH TERMINATION AND TAP USING ALL THREE LISTED IDENTIFICATION PRODUCTS, WHERE IT IS ACCESSIBLE IN A CABINET OR JUNCTION OR OUTLET BOX, AND ELSEWHERE AS INDICATED. 7. EXPOSED CABLES AND CABLES IN CABLE TRAYS AND WIRE TROUGHS: LABEL EACH CABLE AT INTERVALS NOT EXCEEDING 15 FEET. 8. CABLE SCHEDULE POST IN PROMINENT LOCATION IN EACH WIRING CLOSET AND EQUIPMENT ROOM. LIST INCOMING AND OUTCOMING CABLES AND THEIR DESIGNATIONS, ORIGINS, AND DES1TNATTONS, ORIGINS, AND DESTINATIONS. PROJECT WITH RIGID FRAME AND CLEAR PLASTIC COVER. PROVIDE ELECTRONIC COPY OF FINAL COMPREHENSIVE SCHEDULES FOR PROJECT, IN SOFTWARE AND FORMAT SELECTED BY OWNER. Q. FIELD QUALITY CONTROL 1. THE H & M I.T. REPRESENTATIVE RETAINS THE RIGHT TO BE PRESENT AT ANY OR ALL CABLE CERTIFICATION. THE CONTRACTOR SHALL PROVIDE WRITTEN NOTICE 48 HOURS PRIOR TO THE BEGINNING OF THE CERTIFICATION PROCESS. 2. INSPECT THE CABLES FOR DAMAGE PRIOR TO PERFORMING TESTING, IF CABLE IS DAMAGED REPULL CABLE 3. THE CONTRACTOR SHALL PROVIDE A COPY OF CERTIFICATION TEST REPORTS TO THE ENGINEER IN BOTH HARDCOPY AND ELECTRONIC FORMAT. CONTRACTOR SHALL ALSO PROVIDE A COPY OF THE CABLE TESTER'S DATABASE MANAGEMENT SOFTWARE 4. INDEPENDENT SYSTEM CERTIFIED I EsI LNG MAY BE REQUIRED, AT THE DISCRETION OF THE H & M I.T. DEPARTMENT, PROVIDED AT THE EXPENSE OF THE CONTRACTOR, IN THE EVENT OF NON - PERFORMANCE OF THE SPECIFIED TESTING PROCEDURES, SUBMITTALS AND /OR INSTALLATION PROCEDURES. 5. DATA CABLE TEST REPORTS A. UPON COMPLETION OF THE CABLE INSTALLATION, THE CONTRACTOR SHALL PERFORM COMPLETE COPPER CABLE CERTIFICATION TESTS ON EVERY CABLE, INCLUDED BUT NOT LIMITED TO: 1) FOR CATEGORY 5e CABLING AND HIGHER: A WIRE MAP B LENGTH C ATTENUATION D NEAR END CROSS TALK (NEXT) E EQUAL LEVEL FAR END CROSS TALK ELFD(T F) PROPAGATION DELAY AND DELAY SKEW G) RETURN LOSS B. TEST SHALL BE PERFORMED TO PUBLISHED STANDARDS, INCLUDING, BUT NOT LIMITED TO, THE LATEST REVISIONS OF EIA/71A 568, ISO /IEC 11802 AND OTHER APPLICABLE STANDARDS AT THE TIME OF INSTALLATION. C. ALL TESTS SHALL BE PERFORMED WffH A CERTIFIED TEST DEVICE D. TESTER SHALL BE FACTORY CALIBRATED EACH CALENDAR YEAR BY THE FIELD TEST EQUIPMENT MANUFACTURER AS STIPULATED BY THE MANUALS PROVIDED WITH THE HELD TEST UNIT. THE CALIBRATION CERTIFICATE SHALL BE PROVIDED, UPON REQUEST, TO THE H & M LT. DEPARTMENT. E AUTO TEST SETTINGS PROVIDED IN THE FIELD TESTER FOR TESTING THE INSTALLED CABLING SHALL BE SET TO THE DEFAULT PARAMETERS. F. TEST SETTINGS FROM OPTIONS PROVIDED IN THE FIELD TESTERS SHALL BE COMPATIBLE WITH THE INSTALLED CABLE UNDER TEST. 6. REMOVE ANY MALFUNCTIONING CABLE, REPLACE / REPULL WITH NEW CABLE AND REi ii AS SPECIFIED ABOVE. R. CLEANING 1. AFTER COMPLETING SYSTEM INSTALLATION, INCLUDING OUTLET FITTINGS AND DEVICES, INSPECT EXPOSED FINISH. REMOVE BURRS, DIRT, AND CONSTRUCTION DEBRIS AND REPAIR DAMAGED FINISH, INCLUDING CHIPS, SCRATCHES, AND ABRASIONS. S. DEMONSTRATION 1. ENGAGE A FACTORY - AUTHORIZED SERVICE REPRESENTATIVE TO TRAIN OWNER'S MAINTENANCE PERSONNEL TO ADJUST, OPERATE, AND MAINTAIN SYSTEMS. A TRAIN OWNER'S MAINTENANCE PERSONNEL ON PROCEDURES AND SCHEDULES FOR STARTING AND STOPPING, TROUBLE - SHOOTING, SERVICING, AND MAINTAINING EQUIPMENT AND SCHEDULES. 2. TRAIN DESIGNATED PERSONNEL IN CABLE -PLANT MANAGEMENT OPERATIONS, INCLUDING CHANGING SIGNAL PATHWAYS FOR DIFFERENT WORKSTATIONS, REROUTING SIGNALS IN FAILED CABLES, AND EXTENDING WIRING TO ESTABLISH NEW WORKSTATION OUTLETS. SECTION 16800 - FAULT CURRENT STUDY A. THE FAULT CURRENT STUDY SHALL BE PERFORMED BY THE DISTRIBUTION EQUIPMENT MANUFACTURER. THE STUDY SHALL BE SUBMITTED TO THE ENGINEER PRIOR TO RECEMNG FINAL APPROVAL OF THE DISTRIBUTION EQUIPMENT SHOP DRAWINGS AND /OR PRIOR TO RELEASE OF EQUIPMENT FOR MANUFACTURE. IF FORMAL COMPLETION OF THE STUDY MAY CAUSE DELAY IN EQUIPMENT MANUFACTURE, APPROVAL FROM THE ENGINEER MAY BE OBTAINED FOR A PRELIMINARY SUBMITTAL OF SUFFICIENT STUDY DATA TO ENSURE THAT THE SELECTION OF DEVICE RATINGS AND CHARACTERISTICS WILL BE SATISFACTORY. B. THE FAULT CURRENT STUDY SHALL BE PERFORMED WITH THE AID OF A 11NDOWS95" BASED COMPUTER PROGRAM. C. THE INPUT DATA SHALL INCLUDE THE POWER COMPANY'S FAULT CURRENT CONTRIBUTION, RESISTANCE AND REACTANCE COMPONENTS OF THE BRANCH IMPEDANCES, THE X/R RATIOS, BASE QUANTITIES SELECTED AND OTHER SOURCE IMPEDANCES. D. SHORT CIRCUIT MOMENTARY DUTY VALUES AND INTERRUPTING DUTY VALUES SHALL BE CALCULATED ON THE BASIS OF THREE PHASE BOLTED SHORT CIRCUITS AT EACH SWITCHGEAR BUS, SWITCHBOARD, DISTRIBUTION PANEL, BRANCH CIRCUIT PANEL, AND OTHER SIGNIFICANT LOCATIONS THROUGH THE SYSTEM. THE SHORT CIRCUIT TABULATIONS SHALL INCLUDE SYMMETRICAL FAULT CURRENTS AND X/R RATIOS. FOR EACH FAULT LOCATION, THE TOTAL DUTY ON THE BUS, AS WELL AS THE INDMDUAL CONTRIBUTION FROM EACH CONNECTED BRANCH, SHALL BE LISTED WITH ITS RESPECTIVE X/R RA110. SECTION 16810 - SOUND EQUIPMENT (ECI) A SOUND EQUIPMENT SHALL BE FURNISHED AS FOLLOWS: 1. SPEAKER CABLING, AND DJ CABLING BY ELECTRICAL CONTRACTOR PER ECI REQUIREMENTS. CONTACT: BART RENO AT ECI (561) 416 -5880 3100 NW BOCA RATON BLVD, SUITE 309 BOCA RATON, FL 33431 FOR PRICING AND ORDER PLACEMENT. 2. RACK AND ASSOCIATED EQUIPMENT IN RACK, SPEAKERS, SPEAKER BACK BOXES AND DJ JACK CABLING. B. THIS CONTRACTOR SHALL INSTALL ALL SPEAKERS, POWER, SPEAKER BACK BOXES, ASSOCIATED CABUNG AND DJ JACK CABUNG. C. SPEAKER LOCATIONS SHOWN ON THE DRAWING ARE FOR BIDDING PURPOSES ONLY. THIS CONTRACTOR SHALL INSTALL AND WIRE SPEAKERS PER BOSE PROVIDED INSTALLATION DRAWINGS. ALL CABLING SHALL BE RUN TO SOUND RACK LOCATION IN LAN ROOM. LEAVE 6 FEET TAILS FOR FINAL CONNECTION TO SOUND EQUIPMENT BY A ECI TECHNICIAN. D. ALL SOUND CABUNG INSTALLED ABOVE LAY -IN CEILINGS SHALL BE SUPPORTED WITH BRIDLE RINGS MOUNTED FROM BUILDING STRUCTURAL MEMBERS AT A MINIMUM OF 5 FEET ON CENTERS. SOUND CABLING INSTALLED ABOVE DRYWALL CEILINGS SHALL BE IN CONDUIT. CONDUIT SHALL BE CONTINUOUS FROM SPEAKER -TO- SPEAKER. HOMERUN FROM LAST SPEAKER TO CASH OFFICE SHALL BE IN CONDUIT. E. A CONDUIT RUN SHALL NOT HAVE MORE THAN THREE (3) BENDS IN A RUN BETWEEN SPEAKERS OR BETWEEN SPEAKER AND SOUND RACK. WHEN A RUN REQUIRES MORE THAN THREE (3) BENDS, A PULL BOX OF SUITABLE SIZE SHALL BE PLACED IN SUITABLE LOCATION TO MEET THE ABOVE CONDITIONS. F. ALL FINAL TERMINATIONS AT THE SOUND RACK SHALL BE DONE BY H &M'S SOUND SYSTEM TECHNICIAN. G. NO SUBSTITUTIONS OF ECI EQUIPMENT IS PERMITTED. THE CONTRACTOR MUST PURCHASE EQUIPMENT DIRECTLY THROUGH BART 0 ECI TO ENSURE COMPATIBILITY WITH THE SYSTEM HEAD END PROVIDED BY H &M. SECTION 15750 RESPONSIBILITY SCHEDULE TECHNOLOGY CONTRACTOR ELECTRICAL CONTRACTOR INSIDE DIAMETER COMPLETE CONDUIT PATHWAY SYSTEM INCLUDING, BUT NOT LIMITED TO CONDUIT, MANHOLES, HAND HOLES, JUNCTION BOXES, OUTLET BOXES, PLASTER RINGS, ECT. 3.3 (0.13) • ARE -RATED PAINTED PLYWOOD BACKBOARDS, FOR TECHNOLOGY USE. 6.1 (0.24) • TECHNOLOGY GROUNDING SYSTEM INCLUDING, BUT NOT LIMITED T0, GROUND CONDUCTORS, COPPER BUS BARS AND ALL ASSOCIATED HARDWARE REQUIRED FOR A COMPLETE GROUNDING SYSTEM. 9.4 (0.34) e 1" SLEEVES AND FIRESTOPPING WHERE REQUIRED 17.8 (0.70) III PROVIDE PULL SIRING IN CONDUIT'S. • • BONDING OF ALL TECHNOLOGY EQUIPMENT INCLUDING, BUT UMITED TO BONDING JUMPERS AND ASSOCIATED HARDWARE. III 1 PROVIDE ALL CAT5E DATA CABLING AND 25 PAIR PHONE CABUNG. • 0 PROVIDE ALL DATA HARDWARE INCLUDING BUT NOT UMITED TO DATA AND PHONE JACKS, PATCH PANELS, FACE PLATES, TECHNOLOGY CABINE1, JHOOKS, CABLE TIES, WIRE MANAGEMENT AND MISC. RACK EQUIPMENT TO MEET SPECIFICATIONS. • 0 FIELD QUALITY CONTROL (TESTING At CERTIFICATION) • 0 IDENTIFICATION PRODUCTS . .824 SOURCES: BICSI TDMM, GENERAL CABLE, SUPERIOR ESSEX REV APR 16 '[uu.1 PERMIT OEM h., US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 tEXPIRES EXPIRES SEP 0 3 2009 NI In THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West 5treetsboro Road (330) 659 -6688 Ph. Richfield. Ohio 44266 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID ® 03/19/08 ADDENDUM B Project No. Scale DrawnBy: 43328 AS NOTED JDM Y:\2008 \2OO8- 0049 \Cad\Mep \2008-0049E5 -3.dwg Drawing No. ELECTRICAL SPECIFICATIONS E5.3 SECTION 16740: DATA CONDUIT FILL REQUIREMENTS TRADE SIZE INSIDE DIAMETER CABLE OUTSIDE DIAMETER mm (in) 3.3 (0.13) 4.6 (0.18) 5.6 (0.22) 6.1 (0.24) 7.4 (0.29) 7.9 (0.31) 9.4 (0.34) 13.5 (0.53) 15.8 (0.62) 17.8 (0.70) In mm 1/2 .622 16 1 1 0 0 0 0 0 0 0 0 3/4 .824 21 6 5 4 3 2 2 1 0 0 0 1 1.049 27 8 8 7 6 3 3 2 1 0 0 1 1/4 1.380 35 16 14 12 10 6 4 3 1 1 1 1 1/2 1.610 41 20 18 16 15 7 6 4 2 1 1 2 2.067 53 30 26 22 20 14 12 7 4 3 2 2 1/2 2.469 63 45 40 36 30 17 14 12 6 3 3 3 3.068 78 70 60 50 40 20 20 17 7 6 6 3 1/2 3.548 91 MAX MAX MAX MAX MAX MAX 22 12 7 6 4 4.026 103 MAX MAX MAX MAX MAX MAX 30 14 12 7 TYPICAL 2 -PAIR CAT 3 CABLE 3 CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE CABLE TYPICAL 4-PAIR CAT TYPICAL 4-PAIR CAT 5E TYPICAL 4-PAIR CAT 6 (WITHOUT DMDER) TYPICAL 4-PAIR CAT 6 (WITH DMDER) OR 4-PAIR ScTP TYPICAL 12 -PAIR CAT 3 UNSHIELDED TYPICAL 25 -PAIR CAT 3 UNSHIELDED TYPICAL 50 -PAIR CAT 3 UNSHIELDED TYPICAL 50 -PAIR CAT 3 SHIELDED ARMM TYPICAL 100 -PAIR CAT 3 UNSHIELDED SOURCES: BICSI TDMM, GENERAL CABLE, SUPERIOR ESSEX REV APR 16 '[uu.1 PERMIT OEM h., US159 SOUTHCENTER MALL 867 SOUTHCENTER MALL TUKWILA, WASHINGTON 98188 tEXPIRES EXPIRES SEP 0 3 2009 NI In THORSON BAKER & Associates, Inc. Consulting Engineers 3030 West 5treetsboro Road (330) 659 -6688 Ph. Richfield. Ohio 44266 (330) 659 -6675 Fax QAQC No. Date Issue 02/06/08 DESIGN DEVELOPMENT 03/07/08 PERMIT, LANDLORD, BID ® 03/19/08 ADDENDUM B Project No. Scale DrawnBy: 43328 AS NOTED JDM Y:\2008 \2OO8- 0049 \Cad\Mep \2008-0049E5 -3.dwg Drawing No. ELECTRICAL SPECIFICATIONS E5.3