Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0247 - WESTFIELD SOUTHCENTER MALL - SHARKY'S WOODFIRE MEXICAN GRIL
SHARKY'S WOODFIRE MEXICAN GRILL 2600 SOUTHCENTER MALL FC-2 ELO8-247 City.f Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -247 Issue Date: 05/20/2008 Permit Expires On: 11/16/2008 Tenant: Name: SHARKY'S WOODFIRE MEXICAN GRILL Address: 2600 SOUTHCENTER MALL FC -2 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: RICHARD HERMAN Phone: 323 465 -7066 Address: 6009 MELROSE AV , LOS ANGELES CA Contractor: Name: YARBROUGH ELECTRIC INC Phone: 360 413 -0870 Address: 8541 DEFIANCE ST SE , OLYMPIA WA Contractor License No: YARBREI980JK Expiration Date: 04/12/2010 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF AN 881 SF SPACE FOR COOKING, PREP, AND SALES AT A NEW FOOD COURT AT THE SOUTHCENTER MALL Value of Electrical: $40,000.00 Fees Collected: $922.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: , I W Date: 11,01 0 I hereby certify that I have read and ellami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this • ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction •• _ •erformance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: "l ✓' 1/4-1 n 6Q7 .pow -t Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -247 Printed: 05-20 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW SHARKY'S WOODFIRE MEXICAN GRILL Permit Number: Status: Applied Date: Issue Date: EL08 -247 ISSUED 03/13/2008 05/20/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regula construction or the performance of work. Si Print Name: Date: S. Z° 0S doc: Cond -Elec EL08 -247 Printed: 05-20 -2008 t • • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukw;la.wa.us Electrical Permit No. Oki -12411' Project No. - 051 (For a /Jic•e use only) ELECTRICAL PERM! f APPLICATION Applications and plans must be complete in order to he accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 4n SCJt(a CE& `0/1 _ MAU King Co Assessor's tax No.: 36,42O oo I 0 Tenant Name: NARIZ`IS 0000Fint' M6XICAr t GRILL Property Owners Name: I:\ ESTAFLEI (Lj "V" I 1 CQ , l2 (H (FL-2 Mailing Address: Suite Number: FC' 2 Floor: 2 New Tenant: 0' Yes .. No ins A(.NCEL S CA gaols r cy- Smtr Lip CONTACT PERSON -- Who do we contact when your permit is ready to be issued Name: Iel CIA Aa R1 AA Ll Mailing Address: Leoci nnM�r. E ( /�� 5[ Ave E -Mail Address: t I-) e'- I��1 At C C i . COM Day Telephone: 313 ).4L - 7o4c Los AMCd-1 Ca ctoct36 ( irp Slate Lip Fax Number: (')'4 c5 • ()cc ELECTRICAL CONTRACTOR INFORMATION Company Name: ICI CT Se E\ Mailing Address: Contact Person: E -Mail Address: (ay ~tale Lip Day 'telephone: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): S '1 0I aoo 00 oo' Scope of Work (please provide detailed information): T kL. ,LIT 2UVCln�tEt47 sC1- AN- ne, 1 S(:). 5P4ce ,ion cr lLit-tG 1 i ft 41.t dAIFS AT A tiIELJ J Ca.(ET AT T14t SX11 -ICE Will service he altered? 0 1 es [/No Adding more than :'0 amps.' ❑ Yes [' No Type of Use: Type of work: ❑ Nc■v E Adduunr ❑ Srr\ rcc (•h;rns'e ❑ Remodel (Q" 1 errant Inrpro entent ❑ I.ov■ Voltage ❑ Generator ❑ I it c Alarm ❑ I ; lecunuuunication ❑ I emporar) Sen. ice Property Ser■ ed by: Puget Sound l met cv ❑ Seattle ( ily I r;�ltt I'.{cr 1 of • • RESIDE:N I'IAL NEW RESIDENTIAL SERVICE ❑ New single Ihmily dwellings 5140.0(1 (including an attached garage) ❑ Garages, pools. spas and outbuildings S75.00 ea ❑ Low voltage systems (alarm. furnace thermostat) 555.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration 575.00 (no addedialtcred circuits) ❑ Service change with added /altered circuits 575.00 number of added circuits S 1 0.01) ea ❑ Circuits added /altered without service change S50.00 (up to 5 circuits) ❑ Circuits added /altered without service change 550.00 (6 or more circuits) 57.00 ea ❑ Meter/mast repair 565.00 ❑ Low voltage systems 555.00 (alarm. furnace thermostat) MULTI-FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 558.00 ❑ 'Temporary service (generator) 575.00 ❑ Manufactured /mobile home service 580.00 (excluding garage or outhuilding) ❑ Carnivals S75.00 Number of concessions 510.00 ea PERMIT APPLICATION NOTES - Value of Construction In all cases. a value of construction amount should he entered by the applicant. This figure will he reviewed and is subject to possible revision by the Permit Center to comply with current Ice schedules. Expiration of Plan Review Applications for which no permit is issued within 180 days fimllowing the date of-application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. the extension shall he requested in writing and justiciable cause demonstrated. 1 IIEREBY CER 1 II"Y 11lA "1 1 !LAVE. READ ANI) EXAMINED 11IIS APPLICA ZION AND KNOW 111E SAME 10 BE TRUI'. UNDER PNNAl. 1 Y OF PERJURY BY THE LAWNS OF I I IE SEA 11: OE WASIIIN(i ION, AND I AM AUI IIORILED TO APPLY FOR 1 IIIS PL.RMI 1 . BUILDING OWNER OR ELECTRICAL ('ONTRA(eFOR: Signature: Print Name: I )ale: -3//721 S' %%7/ CC/ Si ?V.D2) /Coe Day Telephone: 21)G, - 8'42 — 40 7 / 7g/ Mailing Address: 433 kT�ieN �� / %14 i1E r 163_ IDate Application "\eccpted: 11 ,,•: L, •p• u. 1 . .• %i 1., • r7 `tare p 210(b Date yppliuml'n Expires: 01 11•1 )/LA Staff Initials: /may-„ _ 1 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwilama.us RECEIPT 6364200010 2600 SOUTHCENTER MALL TUKW SHARKY'S WOODFIRE MEXICAN GRILL Permit Number: Status: Applied Date: Issue Date: EL08 -247 ISSUED 03/13/2008 05/20/2008 Receipt No.: R08 -03004 Initials: WER User ID: 1655 Payment Amount: $58.00 Payment Date: 08/20/2008 10:04 AM Balance: $0.00 Payee: YARBROUGH ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7164 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 doc: Receipt-06 Printed: 08-20 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -247 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/13/2008 Applicant: SHARKY'S WOODFIRE MEXICAN GRILL Issue Date: Receipt No.: R08 -01614 Payment Amount: $1,098.00 Initials: WER Payment Date: 05/14/2008 08:54 AM User ID: 1655 Balance: $0.00 Payee: WESTWOOD CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 144559 1,098.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 738.00 000.345.832.00.0 360.00 Total: $1,098.00 doc: Receipt -06 Printed: 05 -14 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -247 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/13/2008 Applicant: SHARKY'S WOODFIRE MEXICAN GRILL Issue Date: Receipt No.: R08 -00738 Payment Amount: $184.50 Initials: JEM Payment Date: 03/13/2008 10:44 AM User ID: 1165 Balance: $738.00 Payee: RS HERMAN ARCHITECTS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 10401 184.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 184.50 Total: $184.50 doc: Receipt -06 Printed: 03 -13 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit t. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36 ?0 Project: .... S (44-R. e4 S of Inspection: 2100 " Address: Z400 - Date Called: /"' Special Instructions: Date Wanted: f� I �i tf a.m. p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 0-4 Inspector: 6f1\14CS Date: 0,21 /2 lic`4, ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 2'{7 Project: (5� ! �� Ns Type of Inspection: OK# 66(0 Address: 7 600 Date Called: J0 t I) -rA-rf PC, A -65S C.oPPK LtsJ .— Special Instructions: Date Wanted: ` _ ia: VA m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: OK# 66(0 CG!% J0 t I) -rA-rf PC, A -65S C.oPPK LtsJ /1-' wM(& I A'I z) t LL ARc .511-16i.9 mi t4Ik1t1 I41 . Di,co JnkkcT LE** olrr en a 4Q.. ketnisPEcr Inspector: _1;i &Jo\ IDate: Dsg Jl D� $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit aCti trl PERMIT NO. Project: • ���� Type of Inspection: Address: NIL' w _ AbO I � Date Called: Special Instructions: Date Wanted: I -) p.m. Requester: Phone No: ❑ Approved per applicable codes. Ij Corrections required prior to approval. COMMENTS: PA- f)-,K Cai6t UIawS ESP 1 -4 Inspector: Date: 0 7 /ii (0\r El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be tL. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. H Receipt No.: (Date: �..._ _.2. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION lE- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 1 Prro'ec 0 . ��� Type of Inspection: Addr ss: Date Called: Special Instructions: Date Wanted: , m. Requester: Phone No: pproved per applicable codes. El Corrections required prior to approval. COMMENTS: C6 Wcoy)(c7 4( fi), 11 fries io 4/6 1- f pz ‘27-2,4801/ - '/'CIF, 19. Inspector} Date// b ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 POW t �� Type o t7 (f d witivw Date Called/: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: LJApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Ok 141/)CL CO W\ 4; f/?,vrt c Inspector: Date: MIVI 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION OIL' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 1/7 Pro'ect: , � (0" Type of Inspection:-7 003 Ad re `_Y Date Called: 0 ! Special Instructions: Date Wanted: / / // � Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: fy9. �- ��ime�n rig Inspectp2 /Li Dates,...x2//r ❑ $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: .1..JL.-1•-■LJ.-11.71)1:10 Mar 07 06 11:57a HTE Office rD r1C_MInf-411 mmun • CITY OF TUKWILA - BUILDMIG DIVI$ION 2008 Wasington State Nonteraidoptiattnew Coda Compliance Form nteriort (310) 5761569 p.8 fiCe Vast:4044n Siira• .144shoptiadtd &ow Men lenfaarco Project Cnfo Pruleci Mdtass 140D0f1AW MR( CALI, akeo ovnA °Wy. 0,61.1 2Roitt 1IG "2 tAkielit-ok INACti-11101'00 Avocanttime:c1/4 (1_0 .5-.1\ r _ Acolicsia Memo! 40 Applicant:Mona: 32.3 Project Description Compiance Option Alteration 'Exceptions (004.cl:frown)* 1: ex - sec. 111/.3) D. e, od, Dekt Raeder' 4.44,67 OS -07- 0V For Building rtntert Usti New Sulltibg 0 Adthilen 0 Abington 0 Plans trzteo Referk)WSEC $ncOon ISIS Or controls and tornmissicrning tecioternents. Prescriptive fettgliing Power Aitervonee 0 Sysierra Anatysis ($ee Otsaacatitm Checklist (ov. Indleate Flesciptiva & LPA specs! oteany pn plans.) p40 changes are betng made th 1Se rIg4ting fl 1.-ws 0=VA atm Mu= riga, tllad wage oat Incalased, 4:speco use rot ghertgiatL Mpair. WM Alla wed Lighting Wattage locatton - ram/mom rm:) Occupancy Desctiptlan &F MT ea> 4:R1702,1S401SiarS "- Float Table 1511 (over) -*odanent iffesicepticrff an.iairn LTG4..PA Proposed lighting IAPAti.age Atlarand Watts per le .t I - 3 MEM 111111111.11111111.11.1111.1111111 9a5 Area Itz Allowed Area Votat.Allevrad Watts 11111MINIMMIII M. MIME IMMO 111111111111 1111111111111111.01.1.1111111.111 riMltMag MI MEW vivrftiatiom rumirrommommo mwommommumuma" i re to( Proposed won *effect ex aim cept Total 'aimed Welts for Into OW 13 i : F.ot PrOFasectr.ritare DescdPtiOns ir*thate Elaine Wee. tern? tIro1e,C1- TAL. Wcte tif Notes: inclinfed). Fetlock lighting, tiet 1he length otthe lock Vri Aati In addition to tine Woo: !Pah% arid Walt n. 2. Per proposed Watts/Mors, use rnanufactuie(s fisted meelnaiim kip* =nose Of fl fixture (not *WY that Reap wit:age) and ether =kens as spe^* fii Seeger; 1536. Fcrehted4vtred 4eDatts any, the Meek Wile to the HMO TeehnleatRefetance Adana! tnay also be wasd. j�q trunk lighting. Mike greater of icttratiuntinaire wattage Or Matta d tragic nuatzotect ay 506 or as smiles**, the wattage ofzixrent Ifni:vv. oev ION Of of theftranorOSroOf. . LIot ill theaures . For exempt. %Mina.. Ode section and eyeeinition "Aruba', aced leztve.Wetts/Fleture tannic: FILE COPY E L05-- 241 RFC,r9N7zr . . MAR 1 3 2008 PERiviiT CENTEK U.J! U f . LUDO 11 • YY J. .74J'4O�I000O Mar 07 08 11:58a HTE Office .CITY OF TUKWILA.- BUILDING DIVISION 20136 Wasing(0n Stale Nonresidential Energy Cade C,arnp59nce Farm r ncrcra -uv mmuri (3101 5761569 rr-tut t311/ 1 a P.S Intriar Ling, umma: xoaevnah,. -n roe megasidabns air rte. Occupancy: Prescriptive Spaces Qualificafiost Cht=rklict f rie r Muter if obi rise ei rcioue 31.7 the:ro fi6rWres: a+sagt rs to s rostra dr thletet x f^ Gt1 ill -ttts •sr a a :rottnh i br Cade OeaPy 1 21) ineieatc Mass ipa -^en a* pima it rya *dried do IPA C1c1Tctt1. LE 15.1 Unit Ltgtitln0 • uses' awn o Warehouses, storage areas or tircral storage hangers c Ogler C it 35% re more of Gytt;lrag ;billy with 1.2.0:3 and nest ore Wasted. 1. Ftrofbscsvt fattufas which of* non - lensed udh a) t ore two tamps, of refiedei of touve . d 5-do wart T S, T-2. 1-4. T4. T4 ISrrmph, aftd d} herd -Wiled eI r. tran1Gd:'+'cming bettssts. Saew4n 171npact firms rfosres •do nrx tpr 8fy 2, hIntal Halltte with a) t latdd( b) ceramic UN lamps sh IS& 4 electronic baAasLL 3. LEO bgtlis 1 owance ILP# ) facilities of other use types finC9adiing but not Unified schools', l0spdeta, in +i3. r n+a,,honks. churcflesf ' -'1 t os n; aq rs n • restaurants/bate f ' Capita a norsai9 4P1.Za,CS. J3 G t-2 Ocoricranclex nwt0 f" +F wt>1 w, banWietfcontererrcareaf"ribaron t a or spaces - sires no 11nbbsaltotp" shag meg office and other apprcptttc es) or '-7 11 saws ..: age areas gas t t.i 111antrfatd rnrg facility z 11,1 �ilus@ieA � - '71 atnotes tome 1-5-1 1) to cases. In which, o general use and a spec' c use the dated ihe- pact8c use shag apply!, In cases i i which a . 8la ftot.menttat'ted sprscficaily, !!5e Urtlt Power Allowance shall be.dertermlaeit4t tf o building rattier: This deterniinattOfl shad be eased UPS the frtost comparable use specited In the .table. Sea Sececn 1512 for exempt areas. 2} T.M watts per squash foot may ne Increased, try two pereert per loot of ceiling height above IWerb tae:. unless apecN+cally directed otherwise blf.sutsseacle0t•foothabaa. 3) Woos. p @r square foot of roost may be increased -Li two percent oer'foot of ceding height above paeive ieet. R) For ail the spews, su=h as scaling and common areas, use the UnIi Light Power Mamma for a s 8)bl . 8) Wses per square foot of morn may be-increased by two pe trant per toot of ceiling height abouenfoe feet 8) aestved. 7) For conkrence moil anitoffiees less dsan:15i3Et': with NU heightaadstions, a.11ritt.t.fgtuing •Pai►+ar Alfc►vonte or t.t0 'rrfatt be used. a 8) Rosarved. For indo0s sport tournament courts with adier.entlairctotos seating over 5;000, the dolt tighearg Power Allowance for thn court area Is 2.69 wire. to) ospmy wEaftord ilki ivtato% tn6ta d svehht, 2.teat of the vAndi w.;conked. t rite.fitsOticii(ndaw.ts separated ftorrr the rated: spapt by wall or at !east three- auarter•t*ght parBUcns (tausparant or opaque). and11ghtkig lc trai-star-din9 eieglar wherortne IlgNIog moves with the display ant-exerms. Art otfd orst 1.6 wear WlerzitarxIlst.6iSpiay tuminaaes ereeize!itot-prc- A104thet flay -o mp4y w;.th oil three-O.& !alluring: Y.,' /Heated an o mounted_ tratsi a%direstly urn ttr recessed Into the ifltelt jr,ct an the bra ocaustable.ar boi'the horfzardei arrd.vertrcat axe (vertical arts oniy.le aeceptab!e.far fluorescent and othesTndures wait arm points of track ale ennsso t), $ Qlted with LED: tuns .n haaleear ileOlesocid. of bi int?efaitY discfaggle Iemp3 Tt i'sddltihrtei FOklig oattrer.ii-elionied only it the tig1•.tleg f3-etxlta8y tom. 11; Provided that a floor plait, tndlca#ng rack.locallen. and Weld. Is trtlt�rtit'.ed, the equate foa19e for t1ielettouse may tie dos1Ened• tar • canputing the !merlon Ufttt LIgl ting Poser Allowance, as the Now arms' eredd by ra a 'pk the secs. Pace area+ #acre ,!a -only) oil?* racks. Ttir:hefgflt alJanCe deemed ire totnele•2 appita9 lY uJ! [-IC I LuVV J. ••• ..... J UVV Mar 07 08 11:59a HTE Office GI L - BUILDING- DIV SION 2906 !Washington State Normnidenttal nary Cede CastpRertce Form 1 s F I \J I ILI \I • ITU 1-0 NV. I �1t!I1 owe r t310) 5761569 p.10 2G'taVds etim t? R7at 'tle 1F` iCJeO Ga?r 4ati Prat Address Uric that farm'ffyou a 9- daemhg.any tare* help adjuannefits tar:your Ughting t .Pitimarices to IIliDt IUgktint . The Oecupar4/O�cetirlpt shauW vice with the lice" listed tit Cede Table 15.1_ kferd�+ 4R3 approPciete Coiling Haight Limit is feet 12 � at_6O fee) an welch the Austrerd 19 btescd. Tne Muscle %.PA Is =Imaged from ND number ged from 6Na Aaewed Watt& per 111. Cartyr:he Adiestee I.PA to the -COre.Ip" eettkt2 .v.vi d Watts Det * titan an CTGSUIei, pale Adjusted Li • tin ; Power Allowances (Interior) ..... -,...... irmimri Mill1111IIIIIIIIIIIMIIIIIIIM min TAMIZ11.11.11111•11e1M1 ITI IIIIIIMM iiillIMIllimiiii 11111111111111111111111.1111111111111•Ideff111.111.1 Illimilailli 01111111•11111•11111111M 11•111111111111. 11111 11111.1111•111.1111111111111.1111 -.t�wTeoro- -monnmoaate. Attd waz pec a •' Ire111111.1111.0.11111 11 May 30, 2008 • city of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Richard Herman 6009 Melrose Avenue Los Angeles, CA 90038 RE: Letter of Incomplete Application # 1 — Revision #1 Electrical Permit Application EL08 -247 Sharky's Woodfired Mexican Grill — 2600 Southcenter Mall, Suite FC -2 Dear Mr. Herman, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 25, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Bill Buterbaugh, at 206 973 -4750, if you have any questions concerning the following comments. 1. Provide mounting detail for transformer wall mount — seismic design and engineering. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely, Brenda Holt Permit Coordinator Enclosures File: EL08 -247 P:\Permit CenterUncomplete Letters\2008\EL08- 247 Inc Ltr #1 to Rev # 1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206 - 431 -3665 • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL08247 DATE: 06 -24 -08 PROJECT NAME: SHARKY'S WOODFIRE MEXICAN GRILL SITE ADDRESS: 2600 SOUTHCENTER MALL FC -2 Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 X Revision # 1 After Permit Issued DEPARTTMEN S: ui ding Diviisii n Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF/COMPLETENESS: (Tues., Thurs.) DUE DATE: 06 -26-08 / Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS Approved Notation: CORRECTIONS: DUE DATE: 07 -24 -08 Approved with Conditions ❑ Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documentslrouting slip.doc 2 -28-02 • PERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -247 DATE: 05 -21 -08 PROJECT NAME: SHARKY'S WOODFIRED MEXICAN GRILL SITE ADDRESS: 2600 SOUTHCENTER MALL FC -2 Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: Buil•l • Di sl•n Public Works -WO Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05 -27 -08 Complete Comments: ❑ Incomplete Not Applicable Permit Center Use Only y INCOMPLETE LETTER MAILED: rl - U /06 LETTER OF COMPLETENESS ILED: Departments determined incomplete: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: / TUESITHURS ROUTING: Please Route UStructural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: n DUE DATE: 06 -24 -08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • PLANPRVI • pcOoU py.ING SLIP ACTIVITY NUMBER: EL08 -247 DATE: 03 -13 -08 PROJECT NAME: SHARKY'S WOO©FIRg MEXICAN GRILL SITE ADDRESS: 2600 SOUTHCENTER MALL FC -2 X Original Plan Submittal Response to. Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: V V kA Bung DiJibion Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 03 -18 -08 Not Applicable • :,:.ta: f+,':. s: ArX.2_r!:•:.:. r.:''�'P.. 7¢'- 4: '+•.vye ••:.iT +1r n.i4;.. x.. �' 'i?'. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04 -15 -08 Not Approved (attach comments) ❑ DATE: Documents/routing slip.doc 2 -28-02 • PROJECT NAME: r S • f rt (Or; it PERMIT NO: t L,O v- SITE ADDRESS: a(ap 0 S Re, -1 ORIGINAL ISSUE DATE: ,s''..20-or REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF IVLS 1� 6-) --�I -O )-0-o Summary of Revision: _ r lOCa � w% ,e �e vast ��w. �� (3 �vvts - � -�''`� 1 Summary of Revision: Received by:ly s0,.a 1. imiz,a ,1 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http. /hvww.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: (r-/-2--4t /d� Plan Check/Permit Number: C D - 7 ❑ Response to Incomplete Letter # Response to Correction Letter # �' 40- Re,., 4i Er Revision # 1 after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: vrk/ S l/uDad 4 r thezi Project Address: Z4. r (So zr c a „/- 127om // -Z Contact Person: Met 4.-44 Phone Number: -Zoe- - 6702 - 6,v7 Summary of Revision: -/Z) - e, �- ell 3 S/Z S 71> - e r A A -7o1 - /U FiErFn1ED JUN 2 4 2008 Sheet Number(s): --/c4- #-‘74 3 /4-70/ "Cloud" or highlight all areas 6f revision including date o revisi Received at the City of Tukwila Permit Center by: Entered in Permits Plus on (0:2-11- Q b lapplicationslforms- applications on linelrevision submittal Created: 8 -13 -2004 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Y2-//.0k Plan Check/Permit Number: -L off - ,� ey_7 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Sh4r ky's vv UG C 4 re " Ct2.e Gr 1 /1 Project Address: Z% Dp 6c,44 .e. 0-84-1 Mc /1 - Z Contact Person: 44r --s` a.. /ice[,' c�r4 Phone Number: z ‘ - gaL --‘4,7/ Summary of Revision: P2, - (. o - Pre& : - er-r254-r-true.,- t)-20-14-7-2 ,/-7./....k c ,lQtiiS'- `av`s/c /4. Fie-- 1-i-5 ase el ;ct -- &) , s z et K he S 11 e/ e - 3.0 -- 471i-ez-ns -.rw,- leca:a i 5/4 R2;5 Q remerAde /`c4 /4 .e-15 in czY-s»-a .r).•, spec h4/ CITY OF TUKWIlA MAY 212008 Sheet Number(s): C -1 , d J I. ' 3.0 "Cloud" or highlight all areas of revision including ' r. a of revisio ''FAMIT CE'EG Received at the City of Tukwila Permit Center by: Er—Entered in Permits Plus on ')-V `{015 lapplications\fonns- applications on line\revision submittal Created: 8-13 -2004 CP wicwi• Look Up a Contractor, Electricirl or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License YARBREI980JK Licensee Name YARBROUGH ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602196489 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 8541 DEFIANCE ST SE Address 2 City OLYMPIA County THURSTON State WA Zip 98501 Phone 3604130870 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 4/12/2002 Expiration Date 4/12/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License YARBRBP986JS Electrical Administrator Information License YARBRBP986JS Name YARBROUGH, BYRON P Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date YARBROUGH, BYRON P AGENT 04/12/2002 YARBROUGH, BYRON P PRESIDENT 04/12/2002 • Bond Information i Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= YARBRE1980JK 05/20/2008 ELECTRICAL SPECIFCATIO LANDLORD PLAN CHECK COMMENTS 3 -17 -08 1 !Aviv SYVBOL (Sc LEGEND S\GLE LINE D(AGRAIv 1. CONTRACTOR SHALL APPLY FOR ALL PERMITS AND INSPECTION REQUIRED BY LEGAL AUTHORITIES. 2. ALL WORKS AND MATERIALS SHALL BE IN FULL COMPLIANCE WITH THE LATEST AND MOST STRINGENT APPLICABLE CODE OR REGULATION. 3. CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR ANY ADDITIONAL COSTS FOR MATERIAL OR LABOR TO COMPLY WITH THESE CODES OR REGULATIONS. 4. CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITION OF THE PREMISES ON WHICH THE WORK IS PERFORMED AND FOR THE SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE CONTRACT. 5. ALL EQUIPMENT AND MATERIALS SHALL BE LISTED, LABELED AND INSTALLED PER RECOGNIZED ELECTRICAL TESTING LABORATORY. 6. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER. 7. DESIGN DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION CONDITIONS WILL PERMIT. 8. NOTHING ON THIS DESIGN DRAWINGS SHALL BE DEEMED AS TO VIOLATE THE LATEST AND MOST STRINGENT APPLICABLE CODES OR REGULATIONS. 9. ANY ERROR, OMISSION OR DESIGN DISCREPANCY ON THE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL ENGINEER FOR CLARIFICATION OR CORRECTION DURING BIDDING PROCESS. 10. ALL OPENINGS AROUND ELECTRICAL PENETRATIONS THRU FIRE RESISTANCE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE FlRE STOPPED USING APPROVED METHODS AS DETERMINED BY CODE OR REGULATION. 11. ITEMS INDICATES ON THESE PLANS SHALL BE FURNISHED, INSTALLED AND CONNECTED WITH ALL REQUIRED ACCESSORIES AND PERIPHERALS EVEN IF NOT INDICATED FOR A COMPLETE FUNCTIONAL AND OPERATIONAL SYSTEM, THE INFORMATION GIVEN IS NOT LIMITED TO EXACT LOCATION AND POINT OF CONNECTION AND THE NUMBER OF CONNECTIONS, AND THE CONNECTIONS, AND THE COORDINATION WITH OTHER TRADES. 12. ALL GROUNDING SHALL BE IN FULL COMPLIANCE VVITH NATIONAL ELECTRICAL CODE. INCOMING SERVICE SHALL BE PER UTILITY GROUNDING COMPANY REQUIREMENTS. 13. UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC WITH SCHEDULE 80 PVC BENDS AND STEEL RISERS. ALL UNDERGROUND PVC CONDUITS SHALL CONTAIN A GROUND CONDUCTOR, AND SHALL BE SIZED PER CODE REQUIREMENT. 14. ALL PANELS SHALL BE PANELBOARD WITH BOLT -ON TYPE CIRCUIT BREAKERS, UNLESS NOTED AS LOAD CENTERS, WHICH ARE PLUG -IN TYPE BREAKERS. 15. ALL FUSED DISCONNECTS SHALL BE FUSED PER NAMEPLATE UNLESS NOTED. 16. CONTRACTOR SHALL SUBMIT CATALOG CUTS OF MAIN SWITCH BOARDS BEFORE PLACING ORDERS AND PURCHASE. 17. ALL CONDUCTORS SHALL BE COPPER TYPE THW, THWN, XHHW, 600V INSULATION UNLESS OTHERWISE NOTED. 18. ALL WIRING DEVICES SHALL BE SPECIFICATION GRADE. 19. ALL CONDUITS SHALL BE RIGID CONDUIT OR E.M.T. MINIMUM. CONDUIT SHALL BE SUPPORTED ACCORDING TO CODE. ALL EMPTY CONDUITS SHALL INCLUDE PULL WIRE. 20. FLEXIBLE CONDUITS SHALL BE USED FOR FINAL CONNECTION TO MOTORS AND OTHER VIBRATING EQUIPMENT. EXPANSION COUPLINGS SHALL BE USED AT BUILDING EXPANSION JOINTS. 21. NON METALLIC BUSHINGS OR INSULATED METALLIC BUSHINGS SHALL BE PROVIDED FOR ALL CONDUIT TERMINATION. 22. CONTRACTOR SHALL COORDINATE AND VERIFY MECHANICAL EQUIPMENT CONTROL AND WIRING REQUIREMENTS WITH MECHANICAL CONTRACTOR BEFORE CONSTRUCTION, 23. ALL LIGHTING FIXTURES AS SPECIFIED ARE OR APPROVED EQUAL CATALOG CUTS OF SUBSTITUTIONS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL BEFORE CONSTRUCTION. DESIGNED BY: - DRAWN BY: - DATE 03 -29 -08 SYMBOLS DESCRIPTION DATE: 03.29.2008 104 DUPLEX RECEPTACLE 20A -125V, 2W GROUNDING TYPE, +15" A.F.F. U.O.N. GFI DUPLEX RECEPTACLE: 20A -125V, 2W GROUND FAULT CIRCUIT INTERRUPTER. +15" A.F.F. U.O.N. . ;: "", GFI . QUADPLEX RECEPTACLE: 20A -125V, 2W GROUND FAULT CIRCUIT INTERRUPTER, +15" A.F.F. U.O.N. (E) LANDLORD MAIN DISTRIBUTION, ` LOCATED IN ELECTRICAL \ \ \ y 7. ■ L- \ \ \\ \ \ 480/277V,30, 4W ■ ROOM. \ \ © (E)METER \ ■ 7 i L� (E)200A ,� \ 200AF 3P \\ fi \\ \ \ ELECTRICAL DISTRIBUTION ROOM 1 DUPLEX RECEPTACLE: 20A -125V, 2W + ISOLATED GROUND TYPE, +15" A.F.F. U.O.N. ..;; IG'I" QUADPLEX RECEPTACLE: 20A -125V, 2W + ISOLATED GROUND TYPE, +15" A.F.F. U.O.N. SINGLE RECEPTACLE: 20A -125V, 2W GROUNDING TYPE, +15" A.F.F. U.O.N. TL DUPLEX RECEPTACLE 20A -125V, 2W GROUNDING TYPE, +15" A.F.F. U.O.N. TWISTLOCK RECEPTACLE ', DUPLEX RECEPTACLE: 20A- 125V -2P, 2W GROUNDING TYPE, CEIUNG MTD. U.O.N. *..1 SINGLE RECEPTACLE 20A -220V GROUNDING TYPE, +15" A.F.F. U.Q.N. KIM KIMIAGAR TELEPHONE OUTLET WITH 3/4" CONDUIT TO TEL BACKBOARD. A.F.F. U.O.N. co Q I - I N 0 COMPUTER DATA OUTLET WITH 3/4" CONDUIT TO DATA UNE TERMINAL, +15" A.F.F. U.O.N. i COMBINATION TELEPHONE & DATA OUTLET, +15" A.F.F. U.O.N. WITH 3/4" CONDUIT TO DATA TERMINAL AND TELEPHONE BACKBOARD. TELEVISION OUTLET WITH 3/4" CONDUIT TO TELEVISION TERMINAL, +15" A.F.F. U.O.N. 0 o II [] DISTANCE TOGGLE SWITCH. 20A-125V. FLUSH MO NT AT +48" OR BS NOTED. SUBSCRIPT - AT SYMBOL INDICATES THE FOLLOWING: 2 -- DOUBLE POLE K - KEY t - MANUAL TIME SWITCH D - DIMMER 3 - THREE WAY P - PILOT LIGHT os - OCCUPANCY SENSOR SWITCH 4 - FOUR WAY a, b, c, d. FIXTURES CONTROLLED & QUANTITY OF SWITCHES DISCONNECT SWITCH WITH FUSED AS NOTED j DISCONNECT SWITCH, NON -FUSED I-- r° - J - (E) 2" CONDUIT BY LANDLORD. VERIFY IN®ELD. L = ±130' (TOTAL 4#3 /0 CU +S 1#4 E )D. TO REMAIN. LEASE LINE (TENANT SPACE) YJ MOTOR OUTLET MD: MAIN DISTRIBUTION PANEL LIGHTING OR APPLIANCE PANEL PLYWOOD BACKBOARD FOR MAIN TELEPHONE TERMINATION I CONTRACTOR TO INTERCEPT (E) 2"C AND CONDUIT IT R CONDU CONCEALED NLESS OTHERWISE NOTED. WITH "A " LOCATION O �' (N) 2" CONDUIT ( L= ±20' ) CONDUIT RUN CONCEALED ABOVE CEILING OR WALLS WITH 1/2" CONDUIT -2#12 +1#12 GND. UNLESS OTHERWISE NOTED. 1/2' CONDUIT- -3#12 + 1112 GND. U.O.N. / / / /// 1" CONDUIT -6#12 +1#12 GND. U.O.N. e)200 ,A3P �34� 125A "A" /// a (N) 30, PANEL 277/480V, ieQ 4W, 200 AMPS MCB. - 1-1/4"C, 3 #1 CU -F1#6 GND. �� {[� ,' ►/� �"' T� j 3/4" CONDUIT-412 + 1 12 GND. U.O.N. 4 / / / / /// 1' CONDUIT-7112+1#12 GND. U.O.N. / /// 3/4" CONDUIT -5#12 + 1#12 GND. U.O.N. 1" CONDUIT -8¢12 +1#12 GND. U.O.N. / / /// / / / / / /// CONDUIT RUN EXPOSED T TELEPHONE CONDUIT 2" MINIMUM U.O.N. 1--. !t"�' " ! �t-� "' 1 • / 2 : t rtUr, l'� 7 nr. 0�a CONDUIT STUB -UP D CONDUIT STUB -DOWN 24. PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED WITH SELF CONTAINED EMERGENCY BATTERY PACK AS ACCEPTED BY FIRE MARSHAL. 25. NOT USED. 26. IT IS THE INTENTION OF THE PLANS AND SPECIFICATIONS TO COVER ALL THINGS REQUIRED TO MAKE A COMPLETE AND OPERATIVE SYSTEM. CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS, EQUIPMENT, OR MISCELLANEOUS SERVICE REQUIRED TO ACCOMPLISH THIS RESULT. 27. CONTRACTOR SHALL BID THE PROJECT AS INDICATED AND SPECIFIED ON THE DRAWINGS. WHEN SUBSTITUTING MATERIALS OR EQUIPMENT OTHER THAN AS SPECIFIED ON THE DRAWINGS, CONTRACTOR SHALL SUBMIT CATALOG CUTS AND AMOUNT OF CREDIT FOR SUBSTITUTION TO BID, FOR APPROVAL 28. CONTRACTOR SHALL CONTACT SERVING UTILITY COMPANIES FOR APPROVED ENGINEERING DRAWINGS BEFORE CONSTRUCTION. 29. ALL NOTES AND SCHEDULES LISTED ON DRAWINGS OF OTHER SECTIONS OF THIS PROJECT WITH REFERENCE TO ELECTRICAL CONTRACTOR OR ELECTRICIAN APPLY TO THIS SECTION OF CONTRACT. 30. ALL ELECTRICAL WORK NOTED ON AC AND PLUMBING DRAWINGS TO BE DONE UNDER THIS SECTION. 31. SUBMIT 8 COPIES OF SHOP DRAWINGS FOR APPROVAL WITHIN 35 DAYS OF AWARD OF CONTRACT. CONTRACTOR SHALL VERIFY DIMENSIONS OF EQUIPMENT AND MAKE SURE THEY COMPLY WITH ALL APPLICABLE CODE REQUIREMENTS RELATING TO CLEAR WORK SPACE AROUND EQUIPMENT PRICE TO SUBMITTING SHOP DRAWINGS. 32. SUBMIT 6 COPIES OF MATERIAL UST FOR APPROVAL WITHIN 35 DAYS OF AWARD OF THE CONTRACT. THE RIGHT IS RESERVED TO SUBMITTAL OF ANY SAMPLES OF FURNISHED MATERIAL, IF DEEMED NECESSARY BY THE OWNER. 33. SUBSTITUTION OF ANY MATERIAL OR EQUIPMENT SHALL BE APPROVED BY ARCHITECT BEFORE INSTALLATION. 34. BEFORE FINAL ACCEPTANCE OF WORK CONTRACTOR IS TO INSURE ALL EQUIPMENT, SYSTEMS ARE INSTALLED AND FUNCTIONING PROPERLY BY PERFORMING REQUIRED FIELD TESTS. 35. EXTEND MIN 2" TELEPHONE CONDUIT TO TELEPHONE BACKBOARD UNLESS NOTED OTHERWISE. 36. THIRD PARTY CERTIFICATION: ALL PACKAGED EQUIPMENT SHALL BE INDEPENDENTLY ) (YY`Y1 !�'0 A:L "TA" "Warr. (NEW) TRANSFORMER (BY TENANT CONTRACTOR) litFu�tik 75KVA DRY TYPE TRANSFORMER 480V DELTA - �� , 9bkiiI6 ''` '' 120 /208V WYE 3 PHASE, 4 WIRE SECONDARY LOCATED <. -•- ��t- •�- y= Xi- �ati�u , D HOMERUN TO PANEL HATCH MARKS INDICATE NUMBER OF #12 WIRES IN CODE SIZE CONDUITS U.O.N. /7 TO EXISTING NEAREST C-- #2 GND. T GROUND ROD, AT SPACE ( WALLL MOUNTED. REFER TO SHEET 07/A-413 ® JUNCTION BOX BLDG. STEEL & CW PIPE. FOR LOCATION). D COPY O THERMOSTAT `1 METER 1 MAX. LENGTH ± 10 FEET ®®" ? sue...° Pe 1406 fi _ iS 4,0 V517 T -• - f .a� ,: ::.� :i ir. s.. i . 1F. "MSB" MAIN SERVICE SWITCHBOARD SM MANUAL MOTOR STARTER WITH THERMAL OVERLOAD PROTECTION. e a) 3P0�' "B" 185A 100A 31 "B" Shad be (N) PANEL 120/208V, O .' at f . -. i 81'd 30, 4W, 200 AMPS MCB. open '-. _ _Ai t1• t'- the Building Official p ". a duly authorized representative. ;..T ; �, . ;" Tukwila City BUILDING DIVISION C.O. CONDUIT ONLY W.P. WEATHER PROOF N NEW HP HORSE POWER U.O.N. UNLESS OTHERWISE NOTED E EXISTING LANDLORD GE\ERAL NOTES ' 1 1 " C v /2 , 4#2 CU +1 #4 GND. REVISIONS Na shall be made to the scope 1. ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE, ON BACK WALL, FOR TEMPORARY ELECTRICAL FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. 2. LANDLORD PROVIDED MAIN DISCONNECT MEANS FOR TENANT IN A LANDLORD ELECTRICAL ROOM AS WELL AS CONDUIT AND CONDUCTORS (FEEDER) FROM THE MAIN DISCONNECT MEANS TO A LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE. IF NEEDED TO ACCOMMODATE TENANT CONSTRUCTION, THE TENANT SHALL RELOCATE THE LANDLORD PROVIDED DISCONNECT SWITCH AND ASSOCIATED FEEDER. TENANT SHALL FURNISH AND INSTALL CONDUIT AND CONDUCTORS FROM FUSED DISCONNECT SWITCH TO TENANTS' MAIN FUSED DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANELBOARD. 3. LANDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORD'S ELECTRICAL ROOM. THE LANDLORDOWNED NETWORK METERING SYSTEM WILL METER TENANT POWER CONSUMPTION. 4. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH (1/8") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1 ") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 5. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. 6. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORITY HAVE JURISDICTION. TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNED FIRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT'S EXPENSE. TENANT SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FlRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHAL'S OFFICE. 7. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. HANGERS, CLAMPS AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. • „81» �53A) changes "B1" without Prior apPravat of F--- N PANEL 120/208V, 5 of work 30) 4W, 125 AMPS M.L.O. O Tukwila Buiidmg Division. ' Ian submittal NOTE: Revisions will require a new e and may include additional plan review fees. • NOTES: 1. UTILITYUCO. IPMENT NEW 8c EXISTING SHALL BE RATED AT MIN. AIC RATING OF 2. TENANT CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITION BEFORE BIDDING. TENANT CONTRACTOR TO FIELD MEASURE THE EXACT LOCATION AND DISTANCES FROM MAIN DISTRIBUTION TO ALL NEW PANELS LOCATION THIRD PARTY LABELED AS A SYSTEM FOR IT'S INTENDED USE BY A NATIONAL RECOGNIZED TESTING LABORATORY (NRTL) IN ACCORDANCE WITH OSHA FEDERAL REGULATIONS 29CFR1910.303 AND .399, AS WELL AS NFPA PAMPHLET #70, NATIONAL ELECTRIC CODE (NEC). ARTICLE 90 -7. 37. AS PER NEC, APPROPRIATE CONDUIT AND WIRE TYPE SHALL BE USED FOR WET LOCATIONS, HAZARDOUS LOCATIONS, CORROSIVE ENVIRONMENT OR SIMILAR SPECIAL CONDITIONS 38. ELECTRICAL CONTRACTOR SHALL FURNISH A COMPLETE TYPE WRITTEN IDENTIFICATION DIRECTORY CARD IN EACH ELECTRICAL PANEL IDENTIFYING ALL BRANCH CIRCUITS. 39. NO BX AC MC OR ROMEX TYPE WIRING SHALL BE ALLOWED. DISTRIBUTION. 3. VERIFY ALL DISTANCES IN FIELD. 4. ALL EQUIPMENT AND FEEDER SHOWN DASHED ARE EXISTING TO REMAIN. TENANT CONTRACTOR SHALL FIELD VERIFY EXISTING EQUIPMENT AND FEEDERS FOR N.E.C. COMPLIANCE. SERIES RATING NOTES: To All Contractors: Required note for bidding and installation: All contractors (general contractor as well as all sub - contractors) bidding and awarded to construct this facility are responsible to verify all equipment furnished and supplied and installed at this site. The equipment utility (gas, water, sewer, vent, electrical, building mechanical systems. duct connections, exhaust connections, security, fire alarm, data, phone, etc.) connection must be verified before bidding. These information are not limited to point of connection, locations, type of connections. number of connections, and coordination with other trades. The contractors shall be responsible for reading the equipment specification book as part of the construction documentation. The equipment will include all equipment purchased or furnished or installed by any one' All utility connections and their locations must include all equipment as required by the utility company as well as local codes or the shopping center /Mall requirements. Contractor to verify all requirements before bid. The most stringent requirement shall apply even if not detailed. The contractors are responsible to request for verification of all Mall or Shopping Center requirements as well as any other local /State /Federal requirements. The contractor shall insure all existing systems are verified and functional. Contractor to verify the placement of new equipment are available. All equipment furnished to the contractor as well as purchased by the contractor must be accompanied with full submittal process and Engineers, a approval. The contractor shall p PP follow all installations per local and State Codes and any deviation from codes even if not detailed in plans, any field correction must be performed by the contractor at no cost to the owners. The contractors are responsible to request for all cut sheets for the equipment and if the ment furnished differed from the cut sheets, the contractor shall ad'ust the installation q p I accordingly. All coordination and adjustment among all trades must be performed by the General Contractor. All coordination and the distribution of responsibility for the site is by the general contractor. All bids must be for full and complete installation and complete functional and operational equipment and systems. All accessories and peripherals wires, conduits, pipes, connections, roof penetrations, attachments, supports, and any other requirements will be part of bid for fully functional and complete installation as required by plans and specifications as well as local requirements. All controls, and al interlocking and interfaces among sub -- contractors such as smoke or duct detectors within HVAC units and with all trades not shown on these drawings such as security system, fire alarms system must be well coordinate during bid. The Contractor is Y Ys Ys g responsible for all of above requirements and must include all provisions into the bid and installation. All existing installations & done by others are not part of the scope of this project. If the installation, connections, materials & equipment are not to code or are unsafe, the owner of the building shall be contacted and all corrections to existing work shall be done under separate contract. Engineer is not responsible for any existing conditions or work previously done by others. VOLTAGE DROP CALCULATION AT PANEL "A" = AMPS x L(ft) x 18.7 VOLTAGE DROP V.D. %VD 100 = x C.M. VOLTS AMPS. = 135 (AMPS BEING USED) L = 150' (DISTANCE FROM EXISTING SWITCHBOARD TO PANEL "A ". C.M. = 167800 ( #3/0 RATING) V D - 134 x 150' x 1;132.24 40. IT IS THE ELECTRICAL CONTRACTOR RESPONSIBILITY TO PROPERLY BALANCE ALL CIRCUITS BETWEEN PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITING INDICATED. 41. MINIMUM BUILDING WIRE SHALL BE #12AWG, EXCLUDING CONTROL WIRING. 1. ALL OVER CURRENT DEVICE ENCLOSURES WILL BE IDENTIFIED AS SERIES RATED 110.22 AND LABELED IN ACCORDANCE WITH NEC 2005 . ( ) 2. THE OVER CURRENT DEVICES SHALL BE AIC RATED PER MANUFACTURERS THEEOI OVER CURRENT RRE ELECTRICAL EQUIPMENT. 3. OBTAIN THE AVAILABLE FAULT CURRENT RATING AND PROVIDE PROPER OBTECTION AVR EQUIPMENT. KEYNOTES: 167800 %'VD = 2.24 100 = 0.47% x 480 fauhlicWorks, Building Division PERMIT NUMBER USE EXISTING METER AND DISCONNECT MEANS LOCATED AT LANDLORD SWITCHBOARD. COORDINATE ALL METERING REQUIREMENTS WITH LANDLORD ELECTRIC SERVICE RE' lIR • N '. " " RECEIVED 2 �o� 0 S A/ / :242»i SPECIFIC NOTES: 1. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWING FOR LOCATION OF ANY ARCHITECTURAL, STRUCTURAL, MECHANICAL AND PLUMBING ITEMS OR FEATURES. REFER TO EACH RESPECTIVE DRAWINGS FOR EXACTNESS OF INFORMATION. 2. IF ANY DISCREPANCY WILL OCCUR BETWEEN ELECTRICAL AND ARCHITECTURAL DRAWINGS, THEN THE ARCHITECTURAL WILL GOVERN. 3. ALL WORK SHALL BE PER 2006 IBC AND 2005 NEC ALONG WITH STATE AND LOCAL AMENDMENTS. 4. SUFFICIENT ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT. TENANT CONTRACTOR SHALL EXTEND THE EXISTING CONDUIT AND WIRES TO PANEL A LOCATION. VERIFY IN FIELD IF THE EXISTING WIRE ARE ENOUGH TO EXTEND TO PANELBOARD NEW LOCATION. IF NOT, PULL NEW 4 #3/O CU + 1 #4 GND. O3 CONTRACTOR SHALL PROVIDE AND INSTALLED NEW 200 AMPS PANELBOARD. MAIN CIRCUIT BREAKER IN PANELBOARD SHALL BE SERIES RATED WITH EXISTING FEEDER PROTECTOR C.B. FOR 65K AIC. MIN. REFER TO SHEET E -3.0 FOR THE LOCATION. ( ) O4 NOT USED. O CONTRACTOR SHALL PROVIDE AND INSTALLED NEW PANELBOARD. INTERRUPTING RATING SHALL MATCH THE EXISTING. 6 CONTRACTOR SHALL VERIFY IN FIELD THE LOCATION OF 200A FUSED DISCONNECT O SWITCH PROVIDED BY LANDLORD. REMOVED THE FUSED DISCONNECT SWITCH INTERCEPT THE EXISTING 2" CONDUIT AND EXTEND TO NEW PANELBOARD "A ". SEE LANDLORD GENERAL NOTE 2 FOR OTHER INFORMATION. PERMIT CENTEF �f,. .TAG Y �zr - "•�:: _� _,�� V• r; • al,� °t.. i. �• ` '� ' a ''� oP^: :11 `�M 4,,::,_. �, k sue_.;,,, W-j - •, 2 =•37' T ;,µ �.4, `,'c $9 ', � ; .0 -. �,, ssi:.o ', 1• -. ©1r� ._s'' ,.' - .A; oir-y w DRAWING INDEX 1 E -1.0 GENERAL SPECIFICATION, ELECTRICAL LEGEND, SINGLE UNE DIAGRAM. E-2.0 PANEL SCHEDULE, LIGHTING SCHEDULE & LIGHTING CONTROL DETAIL. E- .0 'I ,L '• 1 - E;spnq>;s 4 -17 -2009 E -4.0 ELECTRICAL LIGHTING AND ROOF PLAN. c , SITE COP l > - REVISION LANDLORD PLAN CHECK COMMENTS 3 -17 -08 1 !Aviv ISSUED FOR PERMIT UUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - DATE 03 -29 -08 REVIEWED BY: - DATE: 03.29.2008 KENN BUTTS A.I.A. Butts FILE #: E- 1.0.DWG SHEET TITLE: GEN. NOTES, SINGLE LINE DIAGRAM & LEGEND SCALE: AS NOTED Kenneth L. Architect <aaaaaaaa BELL CANYON, CA. 91307 TEL (818) 999 4272 FAX. (818) 999 4321 ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL] DAVIS, CA 95616 E -MAIL YASHAVANTOCOX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR DATE 01 -09 -08 co Q I - I N 0 co 0 I co 0 I K7 0 - ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK !Aviv ISSUED FOR PERMIT UUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.29.2008 KENN BUTTS A.I.A. Butts FILE #: E- 1.0.DWG SHEET TITLE: GEN. NOTES, SINGLE LINE DIAGRAM & LEGEND SCALE: AS NOTED Kenneth L. Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANTOCOX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.29.2008 JOB NUMBER: 07936 FILE #: E- 1.0.DWG SHEET TITLE: GEN. NOTES, SINGLE LINE DIAGRAM & LEGEND SCALE: AS NOTED SHEET NUMBER: E -1 .0 GENERAL NOTE: • • VERIFY LOCATION OF ALL OUTLETS TO KITCHEN EQUIPMENT SUPPLIER BEFORE ROUGH —IN. ALSO VERIFY REQUIREMENTS OF EACH PIECE OF EQUIPMENT. FURNISH AND INSTALL AS REQUIRED. SEE MECHANICAL DRAWINGS FOR HVAC CONTROL REQUIREMENTS. FURNISH AND INSTALL AS INDICATED. GENERAL CONTRACTOR MUST COORDINATE ALL ELECTRICAL WORK SHOWN ON THE PLAN WITH ARCH. AND KITCHEN FOOD SERVICE EQUIPMENT PLANS. NOTIFY THE ARCHITECT OF ANY COORDINATION ISSUES ENCOUNTERED PRIOR TO START OF THE WORK ALL COOKING EQUIPMENT AND CONVENIENCE RECEPTACLES LOCATED UNDER THE FOOTPRINT OF EXHAUST HOOD EQUIPPED WITH FIRE SUPPRESSION SYSTEM SHALL BE EQUIPPED WITH SHUNT —TRIP CONTROL AND INTERLOCKED WITH FIRE SUPPRESSION SYSTEM. ALL KITCHEN HOODS FIRE SUPPRESSION SYSTEMS SHALL BE CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. FINAL CONNECTION TO THE LANDLORD'S FIRE ALARM SYSTEM MUST BE BY LANDLORD'S APPROVED FIRE ALARM CONTRACTOR AT TENANTS EXPENSE. KEYNOTE LEGEND: OPROVIDE J —BOX IN ACCESSIBLE LOCATION AND CONNECT TO SIGN AS PER CODE REQUIREMENTS. VERIFY REQUIREMENTS WITH THE ARCHITECT AND SIGN CONTRACTOR. PROVIDE DEDICATED NEUTRAL AND GROUND FOR ALL SIGNS. CONTRACTOR SHALL PROVIDE LIGHTING CONTROL CONTACT AND TIMER. O POWER SUPPLY FOR COMPUTER AND CASH REGISTER SHALL BE WITH ISOLATED GROUND AND ORANGE RECEPTACLE. PROVIDE 1" CONDUIT FOR TELEPHONE /DATA CABLING WITH CAT. 5 CABLES AND ROUTE BACK TO TELEPHONE BACKBOARD. VERIFY EXACT LOCATION AND QUANTITY O. GENERAL CONTRACTOR SHALL INTERCEPT EXISTING CONDUIT STUBBED INTO TENANT SPACE AND EXTEND TO TENANT TELEPHONE BACKBOARD. CONTRACTOR TO FIELD VERIFY EXACT LOCATION AND SIZE OF CONDUIT BEFORE BIDDING. <> CONTRACTOR SHALL VERIFY WITH KITCHEN EQUIPMENT CONSULTANT THE TYPE OF RECEPTACLE REQUIRED FOR EACH EQUIPMENT. VERIFY ALL OUTLETS WITH MANUFACTURER SPECIFICATION. PROVIDE 3/4" CONDUIT FOR LOW VOLTAGE CONNECTION BETWEEN OUTDOOR UNIT AND THERMOSTAT CONTROLLER. 7> 60AS, 60AF, 3P, NEMA 3R ENCL. 600V. PROVIDE 1 -1/4 "C 3 #4 CU + 1#6 GND. QNO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. KEEP 3 FEET CLEARANCE IN FRONT OF ELECTRICAL PANELBOARD AND EQUIPMENT. OTIME CLOCK CONTROLLER: PROVIDE INTERLOCK WIRING FROM OVERRIDE SWITCH TO TIME CLOCK CONTROLLER. INSTALL OVERRIDE SWITCH AT SWITCH BANK. •FOR EXACT LOCATION OF KITCHEN EQUIPMENT RECEPTACLE AND POWER REQUIREMENTS REFER TO KITCHEN DRAWING SHEET F -1 & F -2. <> CONDENSING UNIT ON ROOF (VERIFY LOCATION). 3/4 "C, 2 #10 + 410 GND., 30AS, 25AF, 2P, NEMA 3R ENCL 12 GAS SOLENOID VALVE CONTROL. COORDINATE LOCATION WITH PLUMBING CONTRACTOR. VERIFY EXACT LOCATION IN FIELD. 13 CONTRACTOR SHALL PROVIDE INTERLOCKING CONTROL WIRES AND CONDUIT TO SHUT—OFF ALL ELECTRICAL UNDER HOOD WHEN SYSTEM IS ACTIVATED. PROVIDE INTERLOCKING CONTROL WIRES BETWEEN SYSTEM CONTROL BOX AND SHUNT TRIP BREAKER AT ELECTRICAL PANELBOARD. ALL INETRLOCKING SYSTEM SHALL BE PROVIDE AS PER SYSTEM REQUIREMENTS. ELECTRICAL SYMBOLS I-C) JUNCTION BOX AT WALL eQ JUNCTION BOX ABOVE FLOOR O JUNCTION BOX AT CEILING Q JUNCTION BOX INSTALLED IN EQUIPMENT itig DUPLEX CONVENIENCE OUTLET 11 in !li. W DUPLEX CONVENIENCE OUTLET SINGLE CONVENIENCE OUTLET I. SINGLE PURPOSE POWER OUTLET (230V) ® SINGLE PURPOSE POWER OUTLET VAPORPROOF LIGHT (FURNISHED WITH EQUIPMENT) SWITCH D DROP CORD ASSEMBLY 0 PULLBOX FIRE ALARM PLAN NOTES: 1. ALL FIRE ALARM SYSTEMS BY OTHERS. 2. INSTALLATION OF FIRE ALARM SYSTEM SHALL BE UNDER A SEPARATE PERMIT. ALL REQUIRED FIRE ALARM DEVICES, CONDUITS, WIRES, BACK BOXES, ETC. SHALL BE INSTALLED AT TENANT'S EXPENSE UNDER A SEPARATE PERMIT BY MALL FIRE /LIFE SAFETY CONTRACTOR. KITCHEN EQUIPMENT NOTE: 1. FOR KITCHEN EQUIPMENT SCHEDULE, NOTES AND ADDITIONAL WORKS REFER TO KITCHEN PLANS. C> CEILING MOUNTED J —BOX FOR EXHAUST HOOD. GENERAL CONTRACTOR TO EXTEND CONDUIT AND WIRES DOWN TO HOOD AND MAKE FINAL CONNECTION TO HOOD LIGHT. PROVIDE WIRING AND HOOD WALL SWITCH MOUNTED AT SWITCH BANK. VERIFY EXACT LOCATION IN FIELD. SEE KITCHEN DRAWING FOR EQUIPMENT INTERLOCKING REQUIREMENTS. • NEW TRANSFORMER. SEE SHEET 07 /A -413 FOR EXACT LOCATION • PROVIDE 4" BOX, 1/2" CONDUIT AND WIRES FOR REMOTE PULL STATION AND INTERLOCK WITH FIRE SUPRESSION SYSTEM. COORDINATE LOCATION WITH THE ARCHITECT. VERIFY INTERLOCKING SYSTEM AND QUANTITY OF REMOTE PULL STATION WITH FIRE SUPPRESION SUPPLIER /CONTRACTOR. 17 SWITCH BANK CONFIGURATION : PANEL "B1" CKT #9 : SWITCH "h ". CKT #11 : SWITCH "j", "k ". CKT #6 • SWITCH "ov" (OVERRIDE SWITCH). • J—BOX FOR FIRE SUPPRESSION SYSTEM. VERIFY EXACT LOCATION IN FIELD. CONTRACTOR SHALL PROVIDE INTERLOCKING CONTROL WIRES AND CONDUIT TO SHUT —OFF ALL ELECTRICAL UNDER HOOD WHEN SYSTEM IS ACTIVATED. PROVIDE INTERLOCKING CONTROL WIRES BETWEEN SYSTEM CONTROL BOX AND SHUNT TRIP BREAKER AT ELECTRICAL PANELBOARD. ALL INETRLOCKING SYSTEM SHALL BE PROVIDE AS PER SYSTEM REQUIREMENTS. EQUIPMENT AND UTILITY SCHEDULE LANDLORD PLAN CHECK COMMENTS 3 -17 -08 EQUIPMENT DUTF-ICENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ELECTRICAL ITEM DESCRIPTION QTY MANUFACTURE /MODEL NO. VOLT. KW AMPS HP PH CONN. REMARKS DIRECT OUTLET 10 OFFICE FURNITURE 1 LOT BY OWNER 120 * 1 co O N 0 X VERIFY W /OWNER 12 U/C HTD. CABINET 2 ALTO SHAAM #750 —S /STD 120 310 576 1569 FAX 8.6 1 X 14 WORKTABLE 1 CUSTOM ST /ST 16 U C HID. CABINET 1 ALTO SHAAM #750 —S /STD 120 8.6 1 X 17 HOT FOOD WELL 1 WELLS #HT -300AF 208 13.0 1 X 18 REFRIGERATED TABLE 1 DELFIELD #D4472N -30M 120 12.0 1 X SELF - CONTAINED 23 HEATED SHELF 1 HATCO #GRSB -24 —F 120 3.5 1 X 26 CASH REGISTERS 3 BY OWNER 120 5.0 1 X DEDICATED CIRCUIT 28 PIZZA OVEN HOOD 1 CAPTIVE AIR 120 3.0 1 X HOOD LIGHTS. WIRE THRU SWITCH 29 PIZZA OVEN 1 WOODSTONE #4343 230 0.4 1 X 30 FOOD FINISHER 2 HATCO #TFW -461R 208 6.3 1 X 31 REFRRIGERATED STAND 1 DELF1ELD #F2962C 120 8.0 1 X SELF — CONTAINED 32 REFRIGERATED TABLE 1 DELFIELD #4427N -9M 120 6.5 1 X SELF— CONTAINED 35 EXHAUST HOOD 1 CAPTIVE AIR 120 5M 1 X HOOD LIGHTS. WIRE THRU SWITCH 36 EXHAUST FAN SYSTEMS 1 LOT BY GEN. CONT. 208 * 3 X VFY. W /HVAC CONTR. 37 FRYER 2 FRYMASTER #FP247 120 1.0 1 X 41 FIRE SUPPRESSION SYSTEM 1 ANSUL #R -102 PART OF ITEM #35 42 WALK—IN COOLER 1 DURACOLD 120 8.0 1 X BLOWER COIL & LIGHTS 4-4 EXHAUST HOOD 1 CAPTIVE AIR 120 3.0 1 X HOOD LIGHTS. WIRE THRU SWITCH 45 FIRE SUPPRESSION SYSTEM 1 PART OF ITEM #35 49 PREP TABLE W /SINK 1 CUSTOM ST /ST 120 11.8 1 X WALL MOUNTED DCO 55 SODA SYSTEM 1 LOT BY SODA VENDOR 57 WORKTABLE 1 CUSTOM ST /ST 120 11.8 1 X WALL MOUNTED DCO 61 ICE MACHINE 1 HOSHIZAKI # KM- 501MAH 120 13.0 1 X 65 REFRIGERATION SYSTEM 1 FOR ITEM #42 208 20.0 1 X 68 SODA /ICE DISPENSER 1 BY SODA VENDOR 120 5.0 1 X CARBONATOR 69 TEA MAKERS 2 BUNN #TU3 120 14.8 1 X K.E.C. — KITCHEN EQUIPMENT CONTRACTOR. G.C. — GENERAL CONTRACTOR, OWN. — OWNER, P.C. — PLUMBING CONTRACTOR, E.C. — ELECTRICAL CONTRACTOR, 0 — OUTLET, C.O. — CONVENIENCE OUTLET, DIRECT — DIRECT CONNECTION, I. W. — INDIRECT WASTE, FD — FLOOR DRAIN F.S. — FLOOR SINK, R.D. --- ROOF DRAIN, F.T. — FLOOR TROUGH To All Contractors: Required note for bidding and installation: All contractors (general contractor as well as all sub — contractors) bidding and awarded to construct this facility are responsible to verify all equipment furnished and supplied and installed at this site. The equipment utility (gas, water, sewer, vent, electrical, building mechanical systems. duct connections, exhaust connections, security, fire alarm, data, phone, etc.) connection must be verified before bidding. These information are not limited to point of connection, locations, type of connections. number of connections, and coordination with other trades. The contractors shall be responsible for reading the equipment specification book as part of the construction documentation. The equipment will include all equipment purchased or fumished or installed by any one. All utility connections and their locations must include all equipment as required by the utility company as well as local codes or the shopping center /Mali requirements. Contractor to verify all requirements before bid. The most stringent requirement shall apply even if not detailed. The contractors are responsible to request for verification of all Mall or Shopping Center requirements as well as any other local /State /Federal requirements. The contractor shall insure all existing systems are verified and functional. Contractor to verify the placement of new equipment are available. All equipment furnished to the contractor as well as purchased by the contractor must be accompanied with full submittal process and Engineers' approval. The contractor shall follow all installations per local and State Codes and any deviation from codes even if not detailed in plans, any field correction must be performed by the contractor at no cost to the owners. The contractors are responsible to request for all cut sheets for the equipment and if the equipment furnished differed from the cut sheets, the contractor shall adjust the installation accordingly. All coordination and adjustment among all trades must be performed by the General Contractor. All coordination and the distribution of responsibility for the site is by the general contractor. All bids must be for full and complete installation and complete functional and operational equipment and systems. All accessories and peripherals wires, conduits, pipes, connections, roof penetrations, attachments, supports, and any other requirements will be part of bid for fully functional and complete installation as required by plans and specifications as well as local requirements. All controls, and al interlocking and interfaces among sub—contractors such as smoke or duct detectors within HVAC units and with all trades not shown on these drawings such as security system, fire alarm system must be well coordinate during bid. The Contractor is responsible for all of above requirements and must include all provisions into the bid and installation. All existing installations & connections done by others are not part of the scope of this project. if the installation, connections, materials & equipment are not to code or are unsafe, the owner of the building shall be contacted and all corrections to existing work shall be done under separate contract. Engineer is not responsible for any existing conditions or work previously done by others. \ SWITCI -1 BANK +12" TELEPFfiONE BAS TIME Ct CONTROL STUB UP BOAR REVIEWED FOR CODE COMPLIANCE NEPA 70 - NEC TYPICAL AUG 15 2008 City Of Tukwila BUILDING DIVI ION TYPICAL ELECTRICAL POWER PLAN SCALE • 1/2" = V-0" WATER HE 36KW, 480 REVI LO � TER, V, 3 0 SIGN N )24 -7 RECEIVED MAY 212008 PERMIT CENTEF EXPIRES 4-17 -7(V) REVISION LANDLORD PLAN CHECK COMMENTS 3 -17 -08 ISSUED FOR BIDDING DUTF-ICENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: — DRAWN BY: — DATE 03 -29 -08 REVIEWED BY: — DATE: 03.29.2008 JOB NUMBER: 07936 KENN BUTTS A.I.A. Butts <7 \ SCALE: 1/4"=1"-o" SHEET NUMBER: E--3.0 ISSUE A HEALTH DEPARTMENT SUBMITTAL _ J PERLIMINARY SUBMITTAL A PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITT j TEL. (818) 999 4272 FAX. (818) 999 4321 DATE 01-09-08 co O N 0 103 -06 -08 DAVIS, CA 95616 E —MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING DUTF-ICENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: — DRAWN BY: — CHECKED BY: — REVIEWED BY: — DATE: 03.29.2008 JOB NUMBER: 07936 KENN BUTTS A.I.A. Butts <7 \ SCALE: 1/4"=1"-o" SHEET NUMBER: E--3.0 Kenneth L. Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E —MAIL YASHAVANT@COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR DESIGNED BY: — DRAWN BY: — CHECKED BY: — REVIEWED BY: — DATE: 03.29.2008 JOB NUMBER: 07936 FILE #: E- 3.0.DWG SHEET TITLE: ELECTRICAL POWER PLAN SCALE: 1/4"=1"-o" SHEET NUMBER: E--3.0 19 01 REFLECTED CEILING PLAN SCALE: 1/2" =1'-0" NORTH V REFLECTED CEILING PLAN GENERAL REQUIREMENTS 1. CEILING HEIGHTS SHOWN ARE FROM TOP OF FINISH FLOOR. 2. PAINT HVAC DIFFUSERS & GRILLES, LIGHT FIXTURE TRIMS, ETC. IN PUBLIC AREAS TO MATCH ADJACENT CEILING FINISH. 3. SUSPENDED CEILINGS SHALL COMPLY WITH 2006 I.B.C. TABLE 25 -A AND 16 -0 4. LATERAL FORCE BRACING FOR SUSPENDED ACOUSTIC TILE CEILING: PROVIDE (4) #12 GAUGE WIRES SECURED TO MAIN RUNNER WITHIN 2" OF CROSS RUNNER INTERSECTION AND SPLAYED 90 DEGREES FROM EACH OTHER AT ANGLE NOT TO EXCEED 45 DEGREES FROM PLANE OF CEILING. THESE HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12' -0" 0.C. IN BOTH DIRECTIONS WITH FIRST POINT WITHIN 4' -0" OF EACH WALL. ATTACHMENT OF THE RESTRAINT WIRES TO THE STRUCTURE ABOVE SHALL BE ADEQUATE FOR THE LOAD IMPOSED. SEE DETAILS 10 A-700 A-700 5. PROVIDE (2) #12 GAUGE SUSPENSION WIRES FOR LIGHT FIXTURES IN ACOUSTIC TILE CEILING AREAS 6. INDICATES FINISH SCHEDULE ITEM, SEE FINISH SCHEDULE ON SHEET A -500 7. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ON LIGHT FIXTURES. 8. REFER TO MECHANICAL DRAWINGS FOR MECHANICAL SYMBOLS 9. INSTALL LIGHTING FIXTURES AND AIR DIFFUSERS IN ACCORDANCE WITH 2001 C.B.C. SECTION 4702 AND GUIDELINES STANDARDS AS FOLLOWS: A. LIGHT FIXTURES AND AIR DIFFUSERS WEIGHING MORE THAN 20 POUNDS BUT LESS THAN 56 POUNDS SHALL HAVE TWO NO. 12 GA. HANGERS CONNECTED FROM THE FIXTURE HOUSING TO THE CEILING SYSTEM HANGERS OR TO THE STRUCTURE ABOVE. LIGHT FIXTURES AND AIR DIFFUSERS WEIGHING 56 POUNDS OR MORE SHALL BE B. SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY APPROVED HANGERS. CONNECTION OF LIGHT FIXTURES AND AIR DIFFUSERS TO THE CEILING SYSTEM C. SHALL BE DESIGNED FOR A LATERAL FORCE OF 100 PERCENT OF THE WEIGHT OF THE FIXTURES IN ADDITION TO THE PRESCRIBED VERTICAL LOADING. 10. CEILING MATERIAL FRAME SPREAD INDEX, C.B.C. SECTION 4202(A) TABLE 42 -A: CLASS 111, 76 -200 FLAME SPREAD INDEX. CEILING MATERIAL SMOKE DENSITY, C.B.C. SEC. 4202(B): 450 MAXIMUM TESTED ACCORDING TO C.B.C. STD. 42 -1 11. REFER TO HOOD DRAWINGS FOR EXACT SIZE & LOCATION OF EXHAUST HOODS AND EXHAUST DUCT SHAPES. 12. WORK SHALL COMPLY WITH 2006 IBC ELECTRICAL CODE AND WASHINGTON STATE ENERGY CODE REQUIREMENTS 13. IT IS THE CONTRACTOR'S RESPONSIBUTY TO SURVEY ALL EXISTING ABOVE CEILING CONDITIONS DURING THE BID PHASE AND NOTIFY RS HERMAN ARCHITECTS OF ANY CONFLICTS THAT WOULD PERVENT THIS DESIGN FROM BEING BUILT. THIS INCLUDES, BUT IS NOT LIMITED TO SPRINKLERS PIPES, DUCTWORK, AND STRUCTURE. 14. CEILING HEIGHT TO BE 14' -0" A.F.F. UNLESS OTHERWISE NOTED. 15. COLOR OF ALL COVERPLATES, DEVICES AND SWITCHES TO BE WHITE. REFLECTED CEILING PLAN KEYNOTES 0 1. SUSPENDED 2'- 0 "x4' -O" ACOUSTICAL TILE AND GRID AT 10' -O" A.F.F. TILES TO HAVE NOISE REDUCTIONS COEFFICIENT OF 0.60 -0.70 WITH A MINIMUM ROOM TO ROOM ATTENUATION FACTOR OF 40.0 DECIBELS AND MUST MEET ALL CODE, FLAME SPREAD, FUEL AND SMOKE DEVELOPMENT FACTORS. 2. KITCHEN EXHAUST HOOD SEE DETAIL 17/A -701 ALSO SEE KITCHEN DWG. ON SHT. K -6.01 FOR DETAILS. INK MAT THE EADS MUST BE FULLY RECESSED AND PAINTED WITH DROP DOWN COVER TO ILI . "- ; RDO 1• 0 EX ' I ONS " C 4. 75KVA STEP -DOWN TRANSFORMER ABOVE. REFER TO 10 /A -701 FOR DETAIL. USED • E BE ST S STE ' BBON A EILING MAINTE ..1 CE -PA 0 MA OVEN / T ` IMINATE ANY 6. EMERGENCY LIGHTING MUST BE FULLY RECESSED IN THE FRONT OF HOUSE AREAS. NO SURFACE MOUNT TYPE IS ALLOWED. REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC AUG 1 5 2008 SYMBOL LEGEND City Of Tiikuvila REFLECTED CEILING BUILDING DIVISION A. ALL CEILING SUPPORTS TO BE FROM STRUCTURAL BEAMS AND JOISTS (NOT FROM DECK ABOVE) WITH SEISMIC BRACING REQUIREMENTS FOR THAT REGION. B. LAY -IN ACOUSTICAL TILES CEILING MAY NOT BE USED IN FORWARD SEWNG AREA. TILES TO HAVE NOISE REDUCTION COEFFICIENTS OF .60 - .70 WITH A MINIMUM ROOM TO ROOM ATTENUATION FACTOR OF 40.0 DECIBELS AND MUST MEET ALL CODES, CLAME SPREAD, FUEL AND SMOKE DEVELOPMENT FACTORS. C. ALL SUPPLY AND RETURN GRILLES IN FORWARD SELLING AREA TO BE PAINTED TO MATCH CEILING. D. ALL SPRINKLER HEADS IN THE FORWARD SELLING AREA ARE TO BE FULLY RECESSED AND CONCEALED POP OF COVER TYPE. PAINT TO MATCH CEILING. E. ALL FIXTURES MUST UTILIZE A CLEAR LOW IRON TEMPERED CLEAR GLASS SAFETY LENS AS PER FOOD PREPARATION AND LOCAL ELECTRICAL CODES. Public Warts, BtMng Ilvision PERMIT NUMBER GYPSUM BOARD CEILING OR FURRDOWN X 24" x 24" ACOUSTICAL CEILING TILE AND GRI.t0*'',r LTR# SUPPLY AIR DIFFUSER TION REVISIONin_ RETURN AIR GRILLE ELO8 Z17 SPRINKLER HEADS MUST BE FULLY RECESSED AND PAINT TO MATCH THE ADJACENT CEILING IN FRONT OF HOUSE (SALES) AREAS LIGHTING SCHEDULE A. ALL LIGHTING IN FORWARD SELLING AREA MUST BE INCANDESCENT WITH LOW IRON TEMPERED GLASS SAFETY LENS PER FOOD PREPARATION AND LOCAL CODDS, ON SEPARATE CIRCUIT AND ON SEVEN (7) DAY TIME CLOCK SET TO MALL'S OPERATING HOURS. FOOT CANDEL LEVEL AT COUNTER HEIGHT MUST BE 50 FC. AVERAGE MAINTAINED. B. ALL STOREFRONT LIGHTING MUST BE ON A SEPARATED CIRCUIT. C. EMERGENCY LIGHTING MUST BE FULLY RECESSED IN THE SELLING AREAS. NO SURFACE MOUNTED TYPE IS ALLOWED. TYPE/ SYMBOL CATALOG NO. DISCRIPTION UH 0 BY MANUFACTURER UNDER EXAUST HOOD LIGTH FIXTURE UC TRESCENT T4, 8 WATT FIXTURE 394mm L WITH COOL WHITE TUBE UNDER UPPER CABINET LIGHT FIXTURE ENCORE EMR12/75W/275 EMERGENCY LIGHT FIXTURE RUDD LIGHTING RG 2X4/32W/T8 2' -0" x 4' -0" FLUORESCENT LIGHT FIXTURE WITH CASE A ELATE A4- P400B -P20 4 "O RECESSED DOWN LIGHT FIXTURE �W ELATE LV4-MR16-CP 4 "0 WALL WASHER LIGHT FIXTURE RSA LIGHTING OCT1775/12VMR16 1.34 "0 PINHOLE WALL WASHER REVISION ADDENDUM #1 - L iX N LT CC ELECTRICAL RESUBMIT 1 ISSUED FOR: DESIGNED BY: - DRAWN BY: STIM DATE 03 -25 -08 co 0 1 N 1 0 0 CO 0 1 0 0 1 c0 0 CO 0 1 0 N 1 c0 0 SHEET TITLE: REFLECTED CEILING PLAN Kenneth L. Architect 124 STAGECOACH BELL CANYON, TEL. (818) FAX. (818) SITE CORI RECEIVED JUN 2 4 2008 PERMIT CENTEF aaa <aaa< ISSUE HEALTH DEPARTMENT SUBMITTAL 'PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL DATE 101-09-08 CO 0 1 I 0 co 0 W 0 1 0 SSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING 2600 SOUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: STIM CHECKED BY: RICHARD HERMAN REVIEWED BY: - KENN BUTTS A.I.A. Butts ROAD CA. 91307 999 4272 999 4321 JOB NUMBER: 07936 FILE #: A- 104.DWG SHEET TITLE: REFLECTED CEILING PLAN Kenneth L. Architect 124 STAGECOACH BELL CANYON, TEL. (818) FAX. (818) SITE CORI RECEIVED JUN 2 4 2008 PERMIT CENTEF SSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: STIM CHECKED BY: RICHARD HERMAN REVIEWED BY: - DATE: 03.25.2008 JOB NUMBER: 07936 FILE #: A- 104.DWG SHEET TITLE: REFLECTED CEILING PLAN SCALE: AS NOTED SHEET NUMBER: AIL A -104 SEE SHEET 10/A -701 FOR FRAMING SUPPORT EQ. EQ. 3' AN s✓. i' "4 r.... s s F . `� '�,.... .' L. `'f+ §` .' f^? : �t :.. .. 2 .7 4" COVE TILE BASE TRANSFORMER ELEVATION SCALE: 1/2"= 1 ' -0" f7 OA. F' . F-0„ . e 0 $f 10' -0" A.F.F. e HEATED HOLDING' C ET"S ✓// iii, • PLASTIC ON TOP CABINETS STAINLESS STEEL PULLS OPEN TO BYEOND LP1 4" COVE TILE BASE STAINLESS STEEL BASE CAP FRONT OF EQUIPMENT HEATED HOLDING CABINEI ELEVATION 14' -O" FOOD COURT CEILING LINE 18 "X18" TILE WALL "A. F. F 0" PROVIDE STAINLESS STEEL TRIM AT INSIDE EDGE OF OPENING HAND SINK MANUFACTURER BY ADVANCE TABCO 7 -PS -65 SCALE: 1/2"=1'-0" ADJUSTABLE SHELF - FINISHES BY OWNER OPEN TO BYEOND 4" BASE AS SCHEDULED I 1� ADJUSTABLE SHELVING ELEVATION SCALE: 1/2 " =1' -0" 4" HIGH COVE TILE BASE ±10' -0" 0 JANITOR AREA ELEVATION SCALE: 1/2 " =1' -0" ICE §;ACHIN BAG N BOX ICE STORA BIN \ 7, Fi / \ K\ .f \ /I \ /\ ISSUED FOR: / `\ N,' 03 -25 -08 / 03 rn 0 0 0 \ \ nuiC /' FOR \ '�,,' / < <I' FOR TRAYS `` < \ 7 r/r��ri� TRAYS r./.MY.mp� \/, Architect DATE 0 0 i 0 0 0 0 co 1 1 N 0 0 / 0 0 0 0 0 0 / 0 0 0 / 0 0 / JUN 2 4 1U08 O 0 0 / \\ A ' ' - � \ i ' / / !� 0 0 iii ±10' -0" 0 JANITOR AREA ELEVATION SCALE: 1/2 " =1' -0" ICE §;ACHIN BAG N BOX ICE STORA BIN OFFICE ELEVATION $f10' -0" A.F.�. PLASTIC LAMINATE ON TOP CABINETS STAINLESS STEEL CABINET PULLS CIIND SOLID SURFACE COUNTERTOP 4" COVE TILE BASE SCALE: 1/2 " =1' -0" \ 7, Fi / \ K\ .f \ /I \ /\ ISSUED FOR: / `\ N,' 03 -25 -08 / 03 rn 0 0 0 \ \ nuiC /' FOR \ '�,,' / < <I' FOR TRAYS `` < \ OFFICE ELEVATION $f10' -0" A.F.�. PLASTIC LAMINATE ON TOP CABINETS STAINLESS STEEL CABINET PULLS CIIND SOLID SURFACE COUNTERTOP 4" COVE TILE BASE SCALE: 1/2 " =1' -0" JANITOR AREA ELEVATION WATER HEATER PLASTIC LAMINATE TOP CABINET TOP CABINET MATT STAINLESS STEEL PULLS JANITOR FLOOR SINK SCALE: 1/2 " =1' -0" 14' -0" FOOD COURT CEILING LINE 14' -0" FOOD COURT CEILING LINE 6" HIGH TEMPERED TRANSLUCENT GLASS SCREEN BEHIND P.0.S. - 3 SIDES B2 SOLID SURFACE ON COUNTERTOP STAINLESS STEEL CABINET PULS PLASTIC LAMINATE ON BASE CABINETS 4" COVE TILE BASE 04 A -702 OPEN TO BEYOND 06 A -702 14' -1 04 A -703 EQ. EQ. EQ. 08 A -702 ADDENDUM #1 7, Fi / \ K\ .f \ /I \ ISSUED FOR: o 1 JA 'TIN: SINK JANITOR AREA ELEVATION WATER HEATER PLASTIC LAMINATE TOP CABINET TOP CABINET MATT STAINLESS STEEL PULLS JANITOR FLOOR SINK SCALE: 1/2 " =1' -0" 14' -0" FOOD COURT CEILING LINE 14' -0" FOOD COURT CEILING LINE 6" HIGH TEMPERED TRANSLUCENT GLASS SCREEN BEHIND P.0.S. - 3 SIDES B2 SOLID SURFACE ON COUNTERTOP STAINLESS STEEL CABINET PULS PLASTIC LAMINATE ON BASE CABINETS 4" COVE TILE BASE 04 A -702 OPEN TO BEYOND 06 A -702 14' -1 04 A -703 EQ. EQ. EQ. 08 A -702 co 2' -2" COR u gm NII 111 ............ 1Y2" BRONZE POWDER COATED SQUARE TUBE )" CLEAR TEMPERED GLASS SNEEZE GUARD MENU BOARD SOLID SURFACE ON COUNTERTOP CORIAN 'SHALE' ON COUNTERTOP STAINLESS STEEL CABINET PULLS 0 DHW1 CND PLASTIC LAMINATE ON BASE CABINETS LP1 4" COVE TILE BASE ( B2 KITCHEN ELEVATION SCALE: 1/2"=1'-0" BACKLITE PLEX /TWIGS FACADE 0O DECORATIVE POWDER COATED BRONZE BARS ON HOOD FACADE SHARKY'S 'FIN' LOGO TO BE A SIMILAR MATERIAL /FINISH TO HOOD AND SHALL BE ILLUMINATED BACK -LIT DECORATIVE POWDER COATED BRONZE BARS ON STAINLESS STEEL RIBBON ANN SACK 'HEATH' TILE ON PIZZA OVEN WALL - (M -39) OPEN TO BEYOND A -702 A -703 PIZZA OVEN BY OTHERS SOLID SURFACE WALL CAP TO RETURN DOWN SIDES OF LOW WALL AS SHOWN ANN SACKS 'HEATH' TILE - (M -39) A -703 I........... ........................ .......... ....................... .......... 111E11 =III 111111111 IIIIIIIIII 111111111111111111111111111 MI1111111 4" COVE TILE BASE MILLWORK ELEVATION SCALE: 1/2 " =1' -0" 14' -0" FOOD COURT CEILING LINE 1 TILE TO MATCH CORIAN 'SHALE' COLOR SOLID SURFACE WALL CAP RETURN DOWN SIDES OF LOW WALL AS SHOWN CLEAR TEMPERED GLASS SNEEZE GUARD SOLID SURFACE ON COUNTERTOP B5 " COVE TILE BASE OPEN TO BEYOND 07 A -702 f _I OPEN TO BEYOND 03 02 A -703 • • •_0 II II_1 ■�1 ■ NM! • ■ B 1 II ®_1 ®�■ ormrsirm Js�1� CORIAN 'SHALE' ON COUNTER SEATING AND CEILING WRAP CORIAN 'SHALE' ON 'FOOD FINISHER' COUNTERTOP CLEAR TEMPERED GLASS SNEEZE GUARD SOLID SURFACE WALL CAP TO RETURN DOWN SIDES OF LOW WALL AS SHOWN SOLID SURFACE ON COUNTERTOP STAINLESS STEEL CABINET PULLS PLASTIC LAMINATE ON BASE CABINETS 4" COVE TILE BASE B5 AS SCHEDULE REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC AUG 15 2008 City Of Tukwila BUILDIN DIVI ION MEM MILLWORK ELEVATION SCALE: 1/2"=1' —0" REVISION N•O*L LO8117 DECORATIVE POWDER COATED BRONZE BARS ON HOOD FACADE ANN SACKS 'HEATH' WALL TILE ON PIZZA OVEN - (M -39) CORIAN 'SHALE' ON 'FOOD FINISHER' COUNTERTOP SOLID SURFACE ON CAP WALL & COUNTERTOP ANN SACKS 'HEATH' WALL TILE - (M -39) STAINLESS STEEL COUNTERTOP STAINLESS STEEL CABINETS PULLS PLASTIC LAMINATE ON BASE CABINETS 4" COVE TILE BASE Z 0 CA w C ADDENDUM #1 11 ce /' iil \ ISSUED FOR: DESIGNED BY: — C.) X N,' 03 -25 -08 \,` 03 rn 0 0 0 to '\OPEN nuiC SHEET NUMBER: A- 41 3 FOR : '�,,' <I < <I' FOR TRAYS \, < \ 7 PERLIMINARY SUBMITTAL TRAYS . \ \/, Architect DATE CO 1 a 0 1 0 co 2' -2" COR u gm NII 111 ............ 1Y2" BRONZE POWDER COATED SQUARE TUBE )" CLEAR TEMPERED GLASS SNEEZE GUARD MENU BOARD SOLID SURFACE ON COUNTERTOP CORIAN 'SHALE' ON COUNTERTOP STAINLESS STEEL CABINET PULLS 0 DHW1 CND PLASTIC LAMINATE ON BASE CABINETS LP1 4" COVE TILE BASE ( B2 KITCHEN ELEVATION SCALE: 1/2"=1'-0" BACKLITE PLEX /TWIGS FACADE 0O DECORATIVE POWDER COATED BRONZE BARS ON HOOD FACADE SHARKY'S 'FIN' LOGO TO BE A SIMILAR MATERIAL /FINISH TO HOOD AND SHALL BE ILLUMINATED BACK -LIT DECORATIVE POWDER COATED BRONZE BARS ON STAINLESS STEEL RIBBON ANN SACK 'HEATH' TILE ON PIZZA OVEN WALL - (M -39) OPEN TO BEYOND A -702 A -703 PIZZA OVEN BY OTHERS SOLID SURFACE WALL CAP TO RETURN DOWN SIDES OF LOW WALL AS SHOWN ANN SACKS 'HEATH' TILE - (M -39) A -703 I........... ........................ .......... ....................... .......... 111E11 =III 111111111 IIIIIIIIII 111111111111111111111111111 MI1111111 4" COVE TILE BASE MILLWORK ELEVATION SCALE: 1/2 " =1' -0" 14' -0" FOOD COURT CEILING LINE 1 TILE TO MATCH CORIAN 'SHALE' COLOR SOLID SURFACE WALL CAP RETURN DOWN SIDES OF LOW WALL AS SHOWN CLEAR TEMPERED GLASS SNEEZE GUARD SOLID SURFACE ON COUNTERTOP B5 " COVE TILE BASE OPEN TO BEYOND 07 A -702 f _I OPEN TO BEYOND 03 02 A -703 • • •_0 II II_1 ■�1 ■ NM! • ■ B 1 II ®_1 ®�■ ormrsirm Js�1� CORIAN 'SHALE' ON COUNTER SEATING AND CEILING WRAP CORIAN 'SHALE' ON 'FOOD FINISHER' COUNTERTOP CLEAR TEMPERED GLASS SNEEZE GUARD SOLID SURFACE WALL CAP TO RETURN DOWN SIDES OF LOW WALL AS SHOWN SOLID SURFACE ON COUNTERTOP STAINLESS STEEL CABINET PULLS PLASTIC LAMINATE ON BASE CABINETS 4" COVE TILE BASE B5 AS SCHEDULE REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC AUG 15 2008 City Of Tukwila BUILDIN DIVI ION MEM MILLWORK ELEVATION SCALE: 1/2"=1' —0" REVISION N•O*L LO8117 DECORATIVE POWDER COATED BRONZE BARS ON HOOD FACADE ANN SACKS 'HEATH' WALL TILE ON PIZZA OVEN - (M -39) CORIAN 'SHALE' ON 'FOOD FINISHER' COUNTERTOP SOLID SURFACE ON CAP WALL & COUNTERTOP ANN SACKS 'HEATH' WALL TILE - (M -39) STAINLESS STEEL COUNTERTOP STAINLESS STEEL CABINETS PULLS PLASTIC LAMINATE ON BASE CABINETS 4" COVE TILE BASE Z 0 CA w C ADDENDUM #1 11 ce RFI #2 1 ELECTRICAL RESUBMIT ISSUED FOR: DESIGNED BY: — C.) X L DATE 03 -25 -08 co 1 N iN 0 03 rn 0 0 0 CO 0 0 SHEET TITLE: INTERIOR ELEVATIONS nuiC SHEET NUMBER: A- 41 3 Q1) k < <I < <I' < < < < ISSUE - HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL( A.I.A. • Kenneth L. Butts Architect DATE CO 1 a 0 1 0 co 1 1 N 0 0 1 c0 0 1 M 0 RECE V r JUN 2 4 1U08 P IVOT GENIE -1 -1 2600 SOUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON 02 V. Z ISSUED FOR: DESIGNED BY: — C.) X iNIV REVIEWED BY: — Ce LU a ID lc) la SHEET TITLE: INTERIOR ELEVATIONS nuiC SHEET NUMBER: A- 41 3 Q1) a 0 KENN BUTTS A.I.A. • Kenneth L. Butts Architect 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 RECE V r JUN 2 4 1U08 P IVOT GENIE ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: — DRAWN BY: STIM CHECKED BY: RICHARD HERMAN REVIEWED BY: — DATE: 03.25.2008 JOB NUMBER: 07936 FILE #: A- 413.DWG SHEET TITLE: INTERIOR ELEVATIONS SCALE: AS NOTED SHEET NUMBER: A- 41 3 ELEV. ±14' -0" A.F.F. $(E) ROOF JOISTS $ ELEV. ±11' -0" A.F.F. 2x4 CEILING GRID AIWArAferfflieLMIIMMENIMINIredrifilr /d $ ELEV. ±9' -0" A.F.F. 2x4 CEILING GRID $ELEV. ±8' —O" A.F.F. SECTION VIEW STEP-DOWN TRANSFORMER TRANSFORMER FRONT VIEW (E) STEEL WIDE FLANGE PERLIN ® ±6' -0" O.C. UNISTRUT P1000 CHANNEL WITH P1300 BEAM CLAMPS -SPAN BETWEEN (2) PURLINS OY" THREADED ROD (TYP. 4 CORNERS) EXTEND CEILING TILES VERT. TO UPPER CEILING GRID ELEVATION Q BRACED CONNECTIONS AT WALL SEE PLAN VIEW PARTITION WALL PER PLAN %" F.R. PLYWOOD IN LIEU OF GYPSUM BOARD AT ATTACHMENT TO WALL UNI -STRUT P -1000 CHANNEL X 12" LONG (VERT.) WITH (2) 3/5%, x 1Y" LAG SCREWS INTO BLOCKING WITHIN WALL UNI -STRUT A1026 BRACKET EA BRACE CONN. TO WALL (4) cb Y" THREADED SUPPORT RODS EA. CORNER TO ROOF STRUCTURE (4) UNISTRUT P1000 1" CHANNEL -- 1" FIRE RETARDANT PLYWOOD DECK UNISTRUT P1036 PLATES (TYP. EA. CONNECTION) 31— o"(v.I.F.) PLAN VIEW 10 TRA \SFORMER DETAILS SCALE: 3/4 " =1 ' -0" NOTES: 1. ELECTRICAL SUBJECT TO INSPECTION. 2. ALL SIGNS REQUIRE SEPARATE PERMITS AND APPOVALS. 3. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 4. ALL ELECTRICAL EQUIPMENT EXPOSED TO WEATHER SHALL BE LISTED FOR EXTERIOR USE. 5. CONTRACTOR SHALL USE A CODE APPROVED WIRING METHOD OF THE FOLLOWING: A) ALL CONDUITS BELOW SLAB OR GRADE SHALL BE PVC AND SHALL INCLUDE A GROUND WIRE. B) ALL EXPOSED CONDUITE SHALL BE EMT. C) ALL CONDUCTORS FOR FEEDERS AND BRANCH WIRING SHALL BE COPPER. D) CONCEALED BRANCH WIRING MAY BE TYPE MC OR AC CABLE, IF APPROVED FOR USE BY JURISDICTION. 6. ALL ELECTRICAL PENETRATIONS INTO THE WALK -IN COOLER SHALL BE SEALED PER SECTION 300 -7 OF THE NEC. 7. PROVIDE SEPARATE CONTACTOR FOR CHEF BASE TO ALLOW CHEF BASE POWER TO REMAIN ON WHEN OTHER EQUIPMENT UNDER HOOD IS SWITCHED OFF WITH HOOD - CHEF BASE POWER SWITCHED OFF ONLY BY HOOD ANSUL SYSTEM IN CASE OF FIRE. 8. ALL VISIBLE OUTLETS AND SWITCHED COVERPLATES IN DINING AREA SHALL BE STAINLESS STEEL. 9. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL MATERIALS NECESSARY TO INTERLOCK THE MAKE -UP AIR FAN. EXHAUST HOOD AND OUTLETS AT COOKLINE WITH THE ANSUL SYSTEM IN ORDER TO PROVIDE EMERGENCY EQUIPMENT SHUT DOWN AS REQUIRED BY THE FIRE DEPARTMENT. 10. WHEN SIGNAGE CIRCUITS ARE CONNECTED TO TENANT (DAPHNE'S) PANEL. USE TORK MODEL #1103 TIME CLOCK FOR SIGNAGE CIRCUITS -SET TO POWER ON AT DUSK & OFF AT MIDNIGHT. 11. ALL 125V ELECTRICAL RECEPTACLES LOCATED IN THE KITCHEN AREAS SHALL HAVE GROUND FAULT CIRCUIT INTERRUPTION PROTECTION PER NEC 210.8(B)(2) 12. CONDUCTORS SHALL BE COPPER RATED AT NOT LESS THAN 600 VOLTS. MINIMUM WIRE SIZE SHALL BE #12 AWG. U.O.N. ALL WIRE #8 AWG AND LARGER SHALL BE STANDED, 1110 THRU #12 AWG CONDUCTORS SHALL BE SOLID. USE THE 75'C AMPACITY RATING FOR CONDUCTORS FEEDING EQUIPMENT RATED 100A OR LESS OR FOR EQUIPMENT RATED FOR CONDUCTORS #1 AWG OR LESS. 13. ALL CIRCUIT BREAKERS CONTROLLING FLOURESCENT LIGHTING SHALL SWD LISTED. 14. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL PANELBOARDS & DISCONNECT SWITCHES, WHITE LEIIERS ON BLACK BACKGROUND. 178 "X1 " PERIMETER TRIM 26 GA. STAINLESS STEEL RIBBON WITH SQUARE EDGE ADHERE ON PERIMETER TRIM 1Y "x1" POWDER COATED BRONZE BARS ON ATTACHED TO BRACKET z CO F CID 2'-8" PLAN 'SNAP -IN' BRACKET 1)'"x1 " POWDER COATED BRONZE BAR ON SNAP TO BRACKET STAINLESS STEEL RIBBON SECTION DECORATIVE PIPES TERMINATE AT OR BEFORE SIGN BOX SET IN PLUG BEFORE ANCHORING OPPISTE END AT TRIM SLEEVE PIPE WELDED TO SIGN BOX FRAME OF SIGN BOX HEAVY GAUGE METAL LAGUNA CREAM STONE TILE TO BE PROCURED BY LANDLORD _ AGUNA CREAM STONE TILE TO BE PROCURED BY _ ANDLORD Y" GYP. BOARD ON 6" METAL STUDS AT 16" 0.C. 07 BBD\ DETA SCALE: 3 " =1 ' -0" L 04 ,}TRAL PLIR SCALE: 1 /2 " -1 ' -0" D ETA I 0 1 NIE.}TRAL P SCALE: 1 /2 "= l ' -0" R DETAIL %" TYPE 'X' GYPSUM BOARD ON 15/8" METAL STUDS 16" O.C. ANN STACKS 'HEATH' TILE - VERTICAL WATER TIGHT BASE AS SCHEDULED PIZ7A °VI- \ SCALE: 3 " =1 ' -0" BAS E D ETA I L 05 TILE CREAMA MARFIL - TENANT TO PURCHASE FROM LANDLORD TILE TO BE PROCURED BY LANDLORD DECORATIVE PIPES TERMINATE AT OR BEFORE SIGN BOX FOUR RECESSED SET SCREWS (2 EA. SIDE) MINIMUM SLEEVE PIPE WELDED TO SIGN BOX %" THICK SURFACE APPLIED SHARKY'S LOGO AND SIGNAGE %" THICK ACRYLIC SET TIGHT WITHIN SIGNAGE BOX FRAME BY TENANT - LANDLORD TO APPROVE COLOR NON- ILLUMINATED SIGN BOX BY LANDLORD TILE TO BE PROCURED BY JANDLORD TILE CREAMA MARFIL - TENANT TO PURCHASE FROM LANDLORD *NOTE: LANDLORD IS BUILDING THE BLADE SIGN BOX AND SUPPORTS. TENANT IS ONLY RESPONSIBLE FOR THE FRONT FACE WITHIN SIGN BOX AND SIGNAGE LETTERING. SUBMIT INFORMATION FOR REVIEW AND APPROVAL. NE,TRAL PEIR DI -TAIL SCALE: 1 /2 " =1' -0" N N \ E „TRAL PE SCALE: 1 /2 " =1 ' -0" WALL FINISH BY OTHER TENANT %" GYPSUM BOARD ON 20 GA. 6" METAL STUDS @ 16" 0.C. REVEAL FINISH BY OTHER TENANT _ AGUNA CREAM STONE TILE TO BE PROCURED BY _ ANDLORD Y" STAINLESS STEEL REVEAL LAGUNA CREAM STONE TILE TO BE PROCURED BY LANDLORD SIGNAGE CONTRATOR TO DETERMINE FINAL SPACING FOR PIPES - CONSULT WITH _ ANDLORD FOR FINAL APPROVAL LAGUNA CREAM STONE TILE TO BE PROCURED BY LANDLORD FRAME OF SIGN BOX R DETAIL REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC AUG 15 2000 f 1 ..11 BUILDING DIVISION 1 l" TYPE 'X' GYPSUM BOARD Y2'10 COPPER RIVL I S ON STAINLESS STEEL SHEET WATER TIGHT BASE AS SCHEDULED 1 /8" METAL STUD FRAMING ANN SACKS 'HEATH' TILES ON %" TYPE 'X' GYPSUM BOARD OPEN TO BEYOND 1% "X1" PERIMETER TRIM 1% "x1" POWDER COATED BRONZE BARS ON 26 GA. STAINLESS STEEL RIBBON 3X3 FIRE TREATED WOOD BLOCKING STAINLESS STEEL SHEET WRAP ON EXPOSED FIRE TREATED BLOCKING COPPER RIVETS ON STAINLESS STEEL SHEET v1ETAL CREAMA MARFIL STONE TILE TO BE PROCURED BY LANDLORD 3/4" STAINLESS STEEL REVEALS ±10'_2" A.F.F. CONTINUOUS PIPE FOR SIGN BOX SUPPORT REVISION NOtL PI /ZA OVE\ SCALE: 3 " =1 ' -0" BAST -.DETAIL 06 \E,TRAL PFIR DI-TA SCALE: 1 /2 " -1 '-0" L 03 PLO gob ).1i \E- UTRAL PL SCALE: 1 /2 " -1' -O" D ETA L FRAME OF SIGN BOX HEAVY GAUGE METAL DECORATIVE PIPE WITH PAINTED FINISH BY LANDLORD - NOTE: NOT ALL PIPES PASS THROUGH - COLOR TO BE DETERMINE CREAMA MARFIL STONE TILE TO BE PROCURED BY LANDLORD WALL FINISHES BY TENANT REVISION 1 7h 2 Q z w 0 0 a ELECTRICAL RESUBMIT 1 ISSUED FOR PERMIT 2600 SOUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: — DRAWN BY: STIM DATE co a I 0 N I M O L06-20-08 JOB NUMBER: 07936 KENN BUTTS A.I.A. Butts ROAD CA. 91307 999 4272 999 4321 SHEET TITLE: DETAILS & MISC. SCALE: AS NOTED SHEET NUMBER: 1 A -7 ®1 Kenneth L. Architect 124 STAGECOACH BELL CANYON, TEL. (818) FAX. (818) RECEIVEr JUN 2 42008 PERNIf GENTLE W M cn CA HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL DATE 4 M O G 102 -11 -08 Q col O to 0 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK 1---N'Tiv I ISSUED FOR PERMIT 2600 SOUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: — DRAWN BY: STIM CHECKED BY: RICHARD HERMAN REVIEWED BY: — DATE: 03.25.2008 JOB NUMBER: 07936 KENN BUTTS A.I.A. Butts ROAD CA. 91307 999 4272 999 4321 SHEET TITLE: DETAILS & MISC. SCALE: AS NOTED SHEET NUMBER: 1 A -7 ®1 Kenneth L. Architect 124 STAGECOACH BELL CANYON, TEL. (818) FAX. (818) RECEIVEr JUN 2 42008 PERNIf GENTLE ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: — DRAWN BY: STIM CHECKED BY: RICHARD HERMAN REVIEWED BY: — DATE: 03.25.2008 JOB NUMBER: 07936 FILE #: A-701. DWG SHEET TITLE: DETAILS & MISC. SCALE: AS NOTED SHEET NUMBER: 1 A -7 ®1 ELEC. SPECIFICATION SYMBOL & LEGEND _ SINGLE LINE DIAGRAM 1. CONTRACTOR SHALL APPLY FOR ALL PERMITS AND INSPECTION REQUIRED BY LEGAL AUTHORITIES, 2. ALL WORKS AND MATERIALS SHALL BE IN FULL COMPUANCE WITH THE LATEST AND MOST STRINGENT APPLICABLE CODE OR REGULATION. a CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR ANY ADDITIONAL COSTS FOR MATERIAL OR LABOR TO COMPLY WTTH THESE CODES OR REGULATIONS, 4. CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITION OF THE PREMISES ON WHICH THE WORK IS PERFORMED AND FOR THE SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE CONTRACT. 5, ALL EQUIPMENT AND MATERIALS SHALL BE LISTED, LABELED AND INSTALLED PER RECOGNIZED ELECTRICAL TESTING LABORATORY. 6. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM DATE OF ACCEPTANCE BY OWNER 7, DESIGN DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION CONDITIONS WILL PERMIT. a NOTHING ON THIS DESIGN DRAWNGS SHALL BE DEEMED AS TO VIOLATE THE LATEST AND MOST STRINGENT APPLICABLE CODES OR REGULATIONS. 9. ANY ERROR, OMISSION OR DESIGN DISCREPANCY ON THE PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ELECTRICAL ENGINEER FOR CLARIRCATION OR CORRECTION DURING BIDDING PROCESS. 10. ALL OPENINGS AROUND ELECTRICAL PENETRATIONS THRU RRE RESISTANCE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE RRE STOPPED USING APPROVED METHODS AS DETERMINED BY CODE OR REGULATION, 11. ITEMS INDICATES ON THESE PLANS SHALL BE FURNISHED, INSTALLED AND CONNECTED WITH ALL REQUIRED ACCESSORIES AND PERIPHERALS EVEN IF NOT INDICATED FOR A COMPLETE FUNCTIONAL AND OPERATIONAL SYSTEM, THE INFORMATION GIVEN IS NOT LIMITED TO EXACT LOCATION AND POINT OF CONNECTION AND THE NUMBER OF CONNECTIONS, AND THE CONNECTIONS, AND THE COORDINATION WITH OTHER TRADES. 12. ALL GROUNDING SHALL BE IN FULL COMPLIANCE WITH NATIONAL ELECTRICAL CODE INCOMING SERVICE SHALL BE PER UTLITY GROUNDING COMPANY REQUIREMENTS. 13. UNDERGROUND CONDUITS SHALL BE SCHEDULE 40 PVC WITH SCHEDULE 80 PVC BENDS AND STEEL RISERS. ALL UNDERGROUND PVC CONDUITS SHALL CONTAIN A GROUND CONDUCTOR, AND SHALL BE SIZED PER CODE REQUIREMENT, 14, ALL PANELS SHALL BE PANELBOARD WITH BOLT -ON TYPE CIRCUIT BREAKERS, UNLESS NOTED AS LOAD CENTERS, WHICH ARE PLUG -IN TYPE BREAKERS. 15 ALL FUSED DISCONNECTS SHALT_ BE FUSED PER NAMEPLATE UNLESS NOTED. 16. CONTRACTOR SHALL SUBMIT CATALOG CUTS OF MAIN SWITCH BOARDS BEFORE PLACING ORDERS AND PURCHASE 17. ALL CONDUCTORS SHALL BE COPPER TYPE THW, THWN, XHHW, 600V INSULATION UNLESS OT FIEiRWISE NOTED. 18 ALL WRING DEVICES SHALL BE SPECIFICATION GRADE 19. ALL CONDUITS SHALL BE RIGID CONDUIT OR EMT. MIMMLIM. CONDUIT SHALL BE SUPPORTED ACCORDING TO CODE ALL EMPTY CONDUITS SHALL INCLUDE PULL WIRE 20. FLEXIBLE CONDUITS SHALL BE USED FOR FINAL CONNECTION TO MOTORS AND OTHER VIBRATING EQUIPMENT, EXPANSION COUPUNGS SHALL BE USED AT BUILDING EXPANSION JOINTS. 21, NON METALLIC BUSHINGS OR INSULATED METALLIC BUSHINGS SHALL BE PROVIDED FOR ALL CONDUIT TERMINATION. CONTRACTOR SHALL COORDINATE AND VERIFY MECHANICAL EQUIPMENT CONTROL AND WRING REQUIREMENTS WITH MECHANICAL CONTRACTOR BEFORE CONSTRUCTION, 2a ALL LIGHTING FIXTURES AS SPECIFIED ARE OR APPROVED EQUAL CATALOG CUTS OF SUBSTITUTIONS SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL BEFORE CONSTRUCTION. 24. PROVIDE ILLUMINATED EXIT SIGNS AS REQUIRED WITH SELF CONTAINED EMERGENCY BATTERY PACK AS ACCEPTED BY RRE MARSHAL 25. ALL OUTSIDE BUILDING SECURITY AND PARKING LOT UGHT1NG SHALL BE CONTROLLED BY TIME SWITCH, OR TIME SWITCH CONTROLLED CONTRACTOR TIME SWITCH SHALL BE TORK #7000 SERIES OR EQUAL 24 -HOUR, 7 -DAY ASTROL DIAL, DAY OMITTING DEVICE WHEN WHEN APPLICABLE 26. TT IS THE INTENTION OF THE PLANS AND SPECIFICATIONS TO COVER ALL THINGS REQUIRED TO MAKE A COMPLETE AND OPERATIVE SYSTEM. CONTRACTOR SHALL, FURNISH ALL LABOR MATERIALS, EQUIPMENT, OR MISCELLANEOUS SERVICE REQUIRED TO ACCOMPUSH THIS RESULT. 27. CONTRACTOR SHALL BID THE PROJECT AS INDICATED AND SPECIFIED ON THE DRAWINGS. WHEN SUBSTITUTING MATERIALS OR EQUIPMENT OTHER THAN AS SPECIFIED ON THE DRAWINGS, CONTRACTOR SHALL SUBMIT CATALOG CUTS AND AMOUNT OF CREDIT FOR SUBSTITUTION TO BID, FOR APPROVAL 28. CONTRACTOR SHALL CONTACT SERVING UTILITY COMPANIES FOR APPROVED ENGINEERING DRAWINGS BEFORE CONSTRUCTION. 29. ALL NOTES AND SCHEDULES LUSTED ON DRAWINGS OF OTHER SECTIONS OF THIS PROJECT WITH REFERENCE TO ELECTRICAL CONTRACTOR OR ELECTRICIAN APPLY TO TT-IS SECTION OF CONTRACT. 3a ALL ELECTRICAL WORK NOTED ON AC AND PLUMBING DRAWINGS TO BE DONE UNDER THIS SECTION. 31. SUBMIT 8 COPIES OF SHOP DRAWINGS FOR APPROVAL WITHIN 35 DAYS OF AWARD OF CONTRACT CONTRACTOR SHALL VERIFY DIMENSIONS OF EQUIPMENT AND MAKE SURE THEY COMPLY WITH ALL APPLICABLE CODE REQUIREMENTS RELATING TO CLEAR WORK SPACE AROUND EQUIPMENT PRICE TO SUBMITTING SHOP DRAWINGS, 32. SUBMIT 6 COPIES OF MATERIAL LIST FOR APPROVAL WITHIN 35 DAYS OF AWARD OF THE CONTRACT. THE RIGHT IS RESERVED TO SUBMITTAL OF ANY SAMPLES OF FURNISHED MATERIAL, IF DEEMED NECESSARY BY THE OWNER 3a SUBSTITUTION OF ANY MATERIAL OR EQUIPMENT SHALL BE APPROVED BY ARCHITECT BEFORE INSTALLATION. M BEFORE FINAL ACCEPTANCE OF WORK CONTRACTOR IS TO INSURE ALL EQUIPMENT, SYSTEMS ARE INSTAL 1 Fr) AND FUNCTIONING PROPERLY BY PERFORMING REQUERED ISSUED FOR: DESIGNED BY: — SYMBOLS DESCRIPTION CHECKED BY: — GI DUPLEX RECEPTACLE 20A -125V, 2W GROUNDING TYPE, +15" AFF. U.O.N. ' . ' DUPLEX RECEPTACLE 20A -125V, 2W GROUND FAULT CIRCUIT WTERR TR JPT +15" AFF. U.D.N. .• GFI QUADPLEX RECEPTACLE 20A -125V, 2W MOUND FPLLT CIRCUIT INTERRUPTER, +151 AFT. U.O.N. (E) LANDLORD MAIN DISTRIBUTION, �� IN ELECTRICAL ROOM. \ \ \ i 7 L—‘ \\ \ \ \ \ 480/27 V,30, 4W LOCATED \ —\ \ (E)METER \ i y (0200A5 /,� L� 20OAF v \\ \ \ r \ \ ELECTRICAL DISTRIBUTION ROOM .. 1. DUPLEX RECEPTACLE 20A -125V, 2W + ISOLATED GROUND TYPE, +15' AFF. M.N. :': c " QUADPLEX RECEPTACLE 20A -125V, 2W + ISOLATED GROUND TYPE, +15' AFF. UO.I+L e SINGE RECEPTACLE 20A -125V, 2W GROUNDING TYPE, +151 AFF UON. DUPLEX RECEPTACLE 20A -125V, 2W GROUNDING TYPE, +15' AFF. U.O.N. TMSTLOCK RECEPTACLE '1, DUPLEX RECEPTACLE 20A- 125V -2P, 2W GROUNDING TYPE, CEILING MTD. UON. (MECHANICAL AND ELECTRICAL) SINGLE RECEPTACLE: 20A -220V GROUNDING TYPE, +15" AFF. UOd�. Y TELEPHONE OUTLET WITH 3/4" CONDUIT TO TEL BACKBOARD, +15" AFF UON. Q COMPUTER DATA OUTLET WffH 3/4" CONDUIT TO DATA UNE TERMINAL, +151 AFF. U.O.N. 2 COMBINATION TELEA -ZONE & DATA OUTLET, +15" AFF. UON. WITH 3/41 CONDUIT TO DATA TERMINAL AND TELEPHONE BACKBOARD. IT TELEVISION OUTLET WITH 3/4" CONDUIT TO TELEVISION TERMINAL, +15' A.F.F. UON. *Lin dam-' c"ri 0 11 (E) 2" CONDUIT BY LANDLORD. VERIFY DISTANCE IN FIELD. < . oA -12sv Ruses MOUNT AT +asp oR AS NOTED. sl r TOGGLE SWITCH2 — AT SYMBOL INDICATES THE FOLLOWING 2 - DOUBLE POLE K - KEY t - MANUAL TIME SWITCH D - DIMMER 3 -THREE WAY P -PLOT LIGHT ors - OCCUPANCY SENSOR SWITCH 4 - FOUR WAY a, b, G d FDXTUF S CONTROLLED QUANTITY OF SWITCHES DISCONNECT SWITCH WITH R.ISED AS NOTED DISCONNECT SWATCH, NON -FUSED O > L = t130' EXISTING 4#3/O CU + 1#4 GND. TO REMAIN. L (TOTAL LENGTH = ±130 FEET) 0 +i LEASE LINE (TENANT SPACE) � .. ' MOTOR OUTLET MD: MAIN DISTF UI1ON PANEL 111 LIGHTING OR APPLIANCE PANEL PLYWOOD BACKBOARD FOR MAIN TELEPHONE TERMINATION _ _ I PANEL "A" 277/480V, 4W, CONDUIT RUN CONCEALED BELOW FLOOR OR GRADE WITH 1/2" CONDUIT -2#12 UNLESS OTHERWISE NOTED. CONDUIT RUN CONCEALED ABOVE CEIUNG OR WALLS WITH 1/2" CONDUIT -2 #12 +1#12 GND. UNLESS OTHERWISE NOTED. 1/2• CONDUIT -3#12 + 1#12 GND. U.O.N. 1' 0ONDUIT-6#12 +1#12 GND. U.O.N. / / / /// + 200A ° 3P „A„ < 30, O. 200 AMPS MCB. �4• ONDUT -4#12 + 1#12 GND. U.O.N. 1° CONDUIT -7#12+1#12 GND. U.O.N. / / / / /// 3/4' OONDUT -5#12 + 1#12 GND. UON. 1" OONDUlr- 6#12 +1412 GND. Uali 134A 125A 3P e — 1 -1/4 "C, 3 #1 CU +1#6 GND. / / /// / / / / / /// CONDUIT RUN EXPOSED T MEP-EPHa► CONDUTI 21 MNIMIUIM U.O.N L _ _ _ FILE C , PY REVIEWED FOR Permit No. NCE C ® ®E COmpLIA 1 CONDUIT STUB-UP fl OONDUIT SIUJB -DOWN J CYYYI NAPA ® - NEC "TA" D ( NEW) TRANSFORMER (BY TENANT CONTRACTOR) 75KVA ?Tar review approval iS rtiectdocurrittgerroisdoesandnotongssions.egithorize DRY TYPE TRANSFORMER 480V DELTA - 120 /208V WYE 3 PHASE, 4 WIRE SECONDARY LOCATED AT SPACE (SEE ARCH. DRAWING ° MAR 2 0 20 $ HOME RUN TO PANEL, HATCH MARKS INDICATE NUMBER OF #12 WWES IN CODE SEE CONDUITS UO•N /,, 3/4"C - #2 GND, TO EXISTING NEAREST GROUND ROD, BLDG. �-. VA FOR MTG. DETAIU the violation of any adopted code or �. ,• .« i, La =: ., = `' Q JUNCTION BOX _ of ; • ' , .,,_ _ ,�y �f Tukvuila D ION • S I ELL & CW PIPE Q THB ViOSTAT . , - _ _ ILDIN GND. X1LEN M Q METER . +1 #4 �'� 7A MAX. MA LENGTH _ 10 FEET LECU NGTH Tukwila BUILDING DIVISION MAIN SiVICE SWITCHBOARD SM MANUAL MOTOR STARTER WfTH THERMAL OVERLOAD PROTECTION. o) 200A 3P "g" PANEL " (N) B 120/208V, 3O, 4W, 0. REVISbNS 200 AMPS MCB. No changes shall be made to the scope of work without prior approval o Tukwila ision la Building $��. NOTE: Revisions will require a new plan submittal ��y��� fees. 1 C.O. CONDUIT ONLY WP. WEATHER PROOF N NEW HP HORSE POWER U.O.N. UNLESS OTFfAWISE NOTED E EXISTING -- 185A 100A 3P LANDLORD GENERAL NOTES 1 1/2"C, 42 CU GND. 9 ED F0�. +1 #4 R� teal " Sr �• � •ter __,�: Q t - . _ " �' 9 ' 1. ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE, ON BACK WALL, FOR TEMPORARY ELECTRICAL FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. 2. LANDLORD PROVIDED MAIN DISCONNECT MEANS FOR TENANT IN A LANDLORD ELECTRICAL ROOM AS WELL AS CONDUIT AND CONDUCTORS (FEEDER) FROM THE MAIN DISCONNECT MEANS TO A LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE IF NEEDED TO ACCOMMODATE TENANT CONSTRUCTION, THE TENANT SHALL RELOCATE THE LANDLORD PROVIDED DISCONNECT SWITCH AND ASSOCIATED FEEDER TENANT SHALL FURNISH AND INSTALL CONDUIT AND CONDUCTORS FROM FUSED DISCONNECT SWITCH TO TENANTS' MAIN FUSED DISCONNECT SWITCH OR MAIN CIRCUIT BREAKER EQUIPPED PANELBOARD. a LANDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORD'S ELECTRICAL ROOM. THE LANDLORDOWNED NETWORK METERING SYSTEM WLL METER TENANT POWER CONSUMPTION. 4. TENANTS ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANTS MAIN DISCONNECT SWITCH IN LANDLORDS SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH (1/8") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS, THE MINIMUM SIZE SHALL BE ONE INCH (D) WTI H ONLY THE TENANTS SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. 5. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE NO CONDUIT WLL BE PROVIDED. LANDLORD WLL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENAN f5 SPACE. LL TENANT TELEPHONE EQUIPMENT NOT PERMITTED IN LANDLORDS M TELEPHONE EQUIPMENT ROOM. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANTS TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE RRE CAULKED AS REQUIRED. 6. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THBR INDMDUAL FETE ALARM SYSTEMS OR COMPONENTS, TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY LOCAL AUTHORFTY HAVE JURISDICTION. TENANT SHALL CONTRACT WFTH LANDLORDS DESIGNED FIRE ALARM CONTPACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT'S EXPENSE TENANT SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIRED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWNGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHAL'S OFFICE 7. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. HANGERS, CLAMPS AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. "BT' bin9 . , �TUmPTT? :; A -' 'B1' (N) PANEL 120/208V, 3Xb, 4W, 5 �� o Q 125 AMPS M,L4. Gas 'la � ';' CM pi TV t 1014 =l - - G 01\1 �. .. .4 557 i.9 = ,�U1LD1 '�= . c' 0 , 53A f " °r AI.., Y to 4 -174 \r0 „1 ` NOTES FIELD TESTS. 35. EXTEND MIN 2" TELEPHONE CONDUIT TO TELEPHONE BACKBOARD UNLESS NOTED OTHERWISE 36. THIRD PARTY CERTIFICATION: ALL PACKAGED EQUIPMENT SHALL BE INDEPENDENTLY 1 ALL EQUIPMENT NEW & EXISTING SHALL BE RATED AT MIN. AIC RATING OF UTTLTTY CO. 2. TENANT CONTRACTOR TO FIELD VERIFY ALL DUSTING CONDITION BEFORE BIDDING. TENANT CONTRACTOR TO FIELD MEASURE THE EXACT LOCATION AND DISTANCES FROM MAIN DISTRIBUTION TO ALL NEW PANELS LOCATION DISTRIBUTION 3, VERIFY ALL DISTANCES IN FIELD. 4 ALL EQUIPMENT AND FEEDER SHOWN DASHED ARE EXISTING TO REMAIN. TENANT CONTRACTOR SHALL FIELD VERIFY EXISTING EQUIPMENT AND FEEDERS FOR NEC. SERIES RATING NOTES: To All Contractors Regr red note for biddrig and installation: All re contractors Feral contractor u well as all subcontractors) biding and awarded to construct u this fas. are responsible to verify all equipment furnished and suppled and instated at this site The equipment utilrty (gas, water; sewer; vent electrical, �I systems. duct connections, exhaust carrlections, secuity, fre alarm, data, phone, etc) compaction must be verified before bi Jth mm . These hfoation are not limited to point of correction, locations, type of number ber of connections, and coordination with other trades. The contractors shad be responsible for read the egupment speafication book as part of the construction documentation The equipment wit include all equipment purchased or furnished or nstalled by any one i All utty corrections and they bcations must ineckude all equipment as required by the utilrty company as well as local codes or the shopphg center/Mall requrrements. Contractor to verify all retirements before bid. The most stringent req.irement shall apply even if not detated The contractors are responsble to request for verification of al Mall or Shopping Center requirements as well as any other IocaVState/Federal regirements, The contractor shad mire all existng systems are verified and functional. Contractor to verify the placement of new equipment are available. Al equipment furnished to the contractor as well as purchased by the carmactor must be accompanied with full submittal process and Engineers' approval. The contractor shall follow all hstallatians per local and State Codes and any deviation from codes even if not detailed in plans, any field correction must be performed by the contractor at no cost to the owners. The contractors are responsible to request for all cut sheets for the equipment and if time egdprnent furrished differed from the cut sheets, the contractor shall adjust the installation accordngty. AI coordnation and adjustment among all trades must be performed by the General Contractor. All coordination and the cistnbution of responsbility for the site is by the general contractor. Al bids must be for full and complete installation and complete functional and operational equipment and systems. Al accessories and peripherals wies, conduits, pipes, connections, roof penetrations, attachments, supports, and any other requrements en be part of bid for fully functional and complete installation as ntrac;d by plans and smoke or as well as local requirements. All controls, and at interlocking and interfaces among sub - contractors such as smote or duct detectors within HVAC units and with all trades not shown on these drawings such as security system, fre alarm system exist be well ceordmate during bid The Contractor is responsible for al of above red�.si nts and must rrdk.ide all provisions into the bid and installation. AI existing installations & corrections done by others are not part of the scope of this project If the Vstadation, connections, materials & equipment are not to code or are unsafe, the owner of the budding shall be contacted and all corrections to existing work shad be done u,d r separate contract Engineer b not responsible for any existing condlions or work previously d by others VOLTAGE DROP CALCULATION AT PANEL "A" V.D. AMPS x L(ft) x 18.7 %VD VOLTAGE DROP 100 = = x C.M. VOLTS AMPS =135 (AMPS BEING USED} L = 1<i0' (DISTANCE FROM EXISTING SWITCHBOARD TO PANEL "A". CM. = 167800 (#3/0 RATING) V.D. 134 x 130'x187 1.94 THIRD PARTY LABFI Fr) AS A SYSTEM FOR IT'S INTENDED USE BY A NATIONAL RECOGNIZED TESTING LABORATORY (NRTL) IN ACCORDANCE WITH OSHA FEDERAL REGULATIONS 29CFR1910.303 AND .399, AS WELL AS NEPA PAMPHLET #70, NATIONAL ELECTRIC CODE (NEC). ARTICLE 90-7. 37. AS PER NEC, APPROPRIATE CONDUIT AND WIRE TYPE SHALL BE USED FOR WET LOCATIONS, HAZARDOUS LOCATIONS, CORROSIVE ENVIRONMENT OR SIMILAR SPECIAL CONDITIONS 38, ELECTRICAL CON I FACTOR SHALL FURNISH A COMPLETE TYPE WRITTEN IDENTIFICATION DIRECTORY CARD IN EACH ELECTRICAL PANEL IDENTIFYING ALL BRANCH CIRCUITS. 39. NO BX, AC, MC OR ROMEX TYPE WRING SHALL BE ALLOWED. 40. TT IS THE ELECTRICAL CON I FACTOR RESPONSIBILITY TO PROPERLY BALANCE ALL CIRCUITS BETWEEN PHASES OF THE SYSTEM, REGARDLESS OF CIRCUITING INDICATED. = 167800 = x 100 = 0.4096 %VD = 480 1. ALL OVER CURRENT DEVICE ENCLOSURES WLL BE IDENTIFED AS SERIES RATED AND LABFI FI7 IN ACCORDANCE WITH NEC 2005(110 -22). 2 THE OVER CURRENT DEVICES SHALL BE AIC RATED PER MANUFACTURERS LABELING OF THE ELECTRICAL EQUIPMENT. 3. OBTAIN THE AVAILABLE FAULT CURRENT RATING AND PROVIDE PROPER PROTECTION FOR EQUIPMENT. KEYNOTES: I?ubGC Worits, Building Division PERMIT NUMBER RECEIVED 0 8 - .I MAR 1 3 2008 L-_, / Q PERMIT k rE'- APPS Das>' GENT 41. •. C> USE EXISTING METER AND DISCONNECT MEANS LOCATED AT LANDLORD SWITCHBOARD. COORDINATE ALL METERING REQUIREMENTS WITH LANDLORD ELECTRIC SERVICE REQUIREMENTS, TENANT CONTRACTOR SHALL EXTEND THE DUSTING CONDUIT AND WIRES TO EXISTING PANEL "A" NEW LOCATION, VERIFY IN FIELD F THE EXISTING WIRE ARE ENOUGH TO EXTEND TO PANFLROARD NEW LOCATION. IF NOT, PULL NEW 4#3/0 CU + 1#4 GND. SHALL _ % o p pNTOOR S RE-USE FOR THE LOCATION. 200 AMPS PANELBOARD TO NEW E AND O CONTRACTOR SHALL PROVIDE NEW BRANCH CIRCUIT BREAKER PER PANEL SCHEDULE SEE PANEL SCHEDULE AT SHEET E -2A. NEW BRANCH CIRCUIT BREAKER SHALL MATCH EXISTING INTERRUPTING RATING SPECIRC NOTES: 1 THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY, DO NOT SCALE THE ELECTRICAL DRAWNG FOR LOCATION OF ANY ARCHITECTURAL, STRUCTURAL, MECHANICAL AND PLUMBING ITEMS OR FILATURES. REFER TO EACH RESPECTIVE DRAWINGS FOR EXACTNESS OF INFORMATION. 2. IF ANY DISCREPANCY WILL OCCUR BETWEEN ELECTRICAL AND ARCHTTECTURAL DRAWINGS, THEN THE ARCHITECTURAL WLL GOVERN. 3, ALL WORK SHALL BE PER 2006 IBC AND 2005 NEC ALONG WITH STATE AND LOCAL AMENDMENTS. 4. SUFFICIENT ACCESS AND WORKING SPACE SHALL BE PROVIDED AND MAINTAINED ABOUT ALL ELECTRICAL EQUIPMENT TO PERMIT READY AND SAFE OPERATION AND MAINTENANCE OF SUCH EQUIPMENT. DRAWING INDEX E -1,0 GENERAL SPECIFICATION, ELECTRICAL LEGEND, SINGLE UNE DIAGRAM. E -20 PANEL SCHEDULE, LIGHTING SCHEDULE & LIGHTING CONTROL DETAIL, 05 CONTRACTOR SHALL PROVIDE NEW PANELBOARD. INTERRUPTING RATING SHALL MATCH THE r /1 EXISTING. APPROVED Pt �.Ir 1a,r� C'n�(+irivATiOtic ct4,�11 1•' ^T ",- ^ ".h NOED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE MUM Or'rr:A.L, AU WORK SHALL BE DONE IN s ACCORDANCE WITH THE APPROVED PLANS ye", I5 :'- r3 :2OT TO FiEL.D'NSPECTIOh3 E-3.0 ELECTRICAL POWER PLAN E-4,0 ELECTRICAL LIGHTING AND ROOF PLAN, E -5.0 ENERGY CODE COMPLIANCE FORM REVISION ky3 ISSUED FOR PERMIT DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: — DRAWN BY: — CHECKED BY: — DATE DATE: 03.06.2008 JOB NUMBER: 07936 r«««« SHEET TITLE: GEN. NOTES, SINGLE LINE DIAGRAM & LEGEND KENN BUTTS A.I.A. Rutts ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL .. 1. DATE 01 -09 -08 02 -11 -08 03 -06 -08 BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ky3 ISSUED FOR PERMIT DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: — DRAWN BY: — CHECKED BY: — REVIEWED BY: — DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 1 .O.DWG SHEET TITLE: GEN. NOTES, SINGLE LINE DIAGRAM & LEGEND KENN BUTTS A.I.A. Rutts . Kenneth Architect .. 1. 124 STACECOACII ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E —MAIL YASHAVANTCDCOX_NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: — DRAWN BY: — CHECKED BY: — REVIEWED BY: — DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 1 .O.DWG SHEET TITLE: GEN. NOTES, SINGLE LINE DIAGRAM & LEGEND SCALE: AS NOTED SHEET NUMBER: E--1.0 \r/ .. PANEL SCHEDULE . EXISTING ELECTRICAL PANEL - A 277/480V - 30 - 4W NEW ELECTRICAL PANEL - B 120/208V - 31- 4W NEW ELECTRICAL PANEL - B1 120/208V - 30 - 4W MUD. ISSUED FOR PERMIT PANEL ,All 277/480 V 31) 4 WIRE, RECESSED M I UNTED 200 AMPERE MAIN CB * *� * * 1- * * * * L PANEL "B' 120/208 V 31)4 WIRE RECESSED M I UNTED AMPERE MAIN MIDI, TC -I TC TC GFI * * GFI -i $ PANEL 'B11 120/208 V 304 WIRE RECESSED M I UNTED AMPERE MAIN M.L.❑, * * - GFI DATE LOCATION SEE PLAN 225 AMPERE BUS L I CATI I N SEE PLAN 225 AMPERE BUS L I CATI I N SEE PLAN 125 AMPERE BUS r1<««« ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL (Sc WESTFIELD FINAL SUBMITTAL DATE 01 -09 -08 02 -11 -08 03 -06 -08 BELL CANYON, CA. 91307 TEL. (818) 999 4272 CKT NO. VOLT - AMPERES DESCRIPTION co E OUTLETS PULE/AMPS PHASE A 3 C POLE/AMPS OUTLETS DESCRIPTION FOR PROJECT COORDINATION VOLT - AMPERES CKT ND CKT NO VOLT - AMPERES DESCRIPTION CODE OUTLETS POLE/AMPS PHASE A D C POLE /AMPS OUTLETS DESCRIPTION nnE VOLT - AMPERES CKT NO CKT NO. VOLT - AMPERES DESCRIPTION CODE OUTLETS POLE /AMPS PHASE A B C POLE /AMPS OUTLETS DESCRIPTION Egg VOLT - AMPERES CKT ND CI) A B C REC LTG POLE MPS AMS POLE LTG REC. A B Cb C cI A B Xp C REC LTG POLE ALPS TAWS POLE LTG REC. A Cp B C A B C(? C REC. LTG POLE MPP AM S POLE LTG REC. CI) A B C 17606 PANEL LB /TRANSFORMER 0 1 3 3 1 WATER HEATER - 36KW L 12000 2 1 1200 SODA SYSTEM (#55) K 1 20 1 REFRIGERATED SYSTEM ( #65) L 2080 2 1 330 LIGHTING & EMER/EXTI UGHT L 3 7 20 1 1 FIRE SON SYSTEM 0 800 2 1 25 1 20 � E1 3 18178 - 1�■ - 12000 4 3 1032 U/C HID. CABINET ( #t2) K ... - - -- -1 _ _ I.�� % 1 - 2080 4 3 690 LIGHTING & EMER/EKIT LIGHT L 1 20 1g1 20 1 1 SECURITY SYSTEM 0 500 4 5 17012 - 125 fl 60 - 12000 6 5 1032 U/C HTD. CABINET ( #12) K 1 20 1 1 WALK -IN COOLER (#42) 0 960 6 5 12()0 SIGN / LOGO L 10 20 1 1 1 TIME CLOCK & TELE BOARD 0 500 6 SPARE 3 3 SPARE 8 7 1032 U/C HID. CABINET ( #16) K 1 1 20 1 11 1 WORK TABLE (#57) K 1416 $ 7 540 GEN. RECEPJROOF RECEP R 3 1111 1 AC-1 (5f01� L 2918 S - -- 7 1352 HOT FOOD WELL ( #17) K 1 2 II 1 1560 800 1 - 2 0 III 12 1 1352 - 2 OFFICE FUNNrrUF ( #�) 500 12 9 400 EXHAUST HOOD LIGHT (#44) L 4 1 i1 3 - 2918 12 20 13 SPACE INN SPACE 14 13 1440 REFRIGERATED TABLE ( #18) K 1 1 20 III TEA MAKER (#69) K 1776 14 13 SPARE .111 20 1 1 FA PANEL O 300 14 15 SPACE SPACE 16 15 420 HEATED SHELF ( #23) K 1 1 20 Y 1 TEA MAKER (#69) K 1778 16 15 - _ -.. k :.n :. A • - J 16 ■ii■ 17 SPACE ��i SPACE 18 17 3150 FOOD FINISHER (#30) K 1 ■�40 20 1 2 CASH REGISTER ( #26) R 600 18 17 SPARE 18 II 19 3150 - 2 1 ■■ 24 1 PIZZA OVEN ( #29) K 100 20 19 1��1 20 22 � 1111 21 22 21 3150 FOOD FINISHER (#30) K 1 40 1�■ - 100 22 21 v 23 111 24 23 3150 - 2 `le 20 1 1 GAS SOLENOID VALVE 0 300 24 23 ._ - . SPARE 1 20 1•f1 20 1 SPARE 24 25 26 25 960 REFFdGERATED STAND (#31j K 1 20 1 EXHAUST HOOD -1 0 404 26 £� 1 30 27 111 2$ 27 780 REEF GBRATED STAND (#32) K 1 mu - 2004 28 27 _ ,��� ■��■ 28 111 30 29 120 FRER 0371 K 1 1 3 - 2004 30 29 30 j �""'~ 1�� 32 34 31 600 SODA/ICE DISPENSER (#65) K 1 20 1 1 EXHAUST HOOD - 2 0 1176 3-2 31 . - -_ -.. 1ii1 32 34 Ir!! ■sir 33 33 1416 PREP TABLE W/ SINK (#49) K 2 v Y 111 ma 20 1 1 EXHAUST HOOD - 3 o 1176 34 33 ■1i 35 111 36 35 1416 WORK TABLE (#14) K 1 1 20 ii' 1 SPARE 0 1000 36 35 ill 36 37 38 37 2004 MAKE - UP AIR L 1 30 �D 1 PANEL "Br' 0 5500 38 37 _ 3$ 1111 39 INN 40 39 2004 - 1.e - 6370 40 39 ■�i■ 111 41 2004 - 3 Ifs, 3 - 6148 4 2 21373 22186 20660 SUB - TOTAL 12000 12000 12000 10386 10154 12274 SUB - TOTAL 14.052 15066 11512 870 1490 1600 SUB - TOTAL Q818 3778 3418 33373 34186 32660 24438 25220 23736 4688 5268 5018 • TOTAL CONN. LOAD 100219 NA) LOAD CODE K KITCHEN TOTAL CONN. LOAD 73394 (VA) LOAD CODE K KITCHEN TOTAL CONN. LOAD 14974 (VA) LOAD CODE K KITCHEN LCL & LM 36000 X 125 = 45000 NA) L LONG CONTLOAD/ LC.L & LM. 10172 X 125 = 12715 NA) L LONG CONTLOAD/ LC.L & LM. 12174 X 125 = 15218 (VA) L LONG CONTLOAD/ KIT. EQUIP 0 X 0.65.. 0 NA) (K => 6 @ 65%) LARGEST MOTOR KIT. EQUIP 33480 X 0.65 = 21762 (VA) (K => 6 @ 65%) NOTE; LARGEST MOTOR 0 OTHERS KIT. EQUIP 0 X 0.65 = 0 NA} (K => 6 6596} M LARGEST MOTOR OTHERS REC. < =1OKVA 0 X 1 = 0 (VA) (1ST 10 KVA X100%) 0 OTHERS REC, < =10KVA 1400 X 1 = 1400 (VA) (1ST 10 KVA X100%) $ - PROVIDE LOCK -ON DEVICE ON THESE CIRCUITS. * - PROVIDE ISOLATED GROUND RECEPTACLE REC. < =1DKVA 900 X 1 = 900 NA} (1ST 10 KVA X100%) .e. - PROVIDE LOCK -ON DEVICE ON THESE CIRCUITS, 0 * - PROVIDE ISOLATED GROUND RECEPTACLE REC. REMAINDER 0 X 0.5 = 0 (VA) R RECEPTACLE NOTE REC. REMAINDER 0 X 0.5 = 0 (VA) R TC - PROVIDE 7 -DAY ASTRONOMICAL TIME CLOCK REC. REMAINDER 0 X 05 = 0 NA) R TC - PROVIDE 7 -DAY AS I HONOMICAL TIME CLOCK OTHERS LOAD 64219 X 1 = 64219 (VA) (OTHER @ 100%) $ - PROVIDE LOCK -ON DEVICE ON THESE CIRCUITS, OTHERS LOAD 28342 X 1 = 28342 (VA) (OTHER 0 100%) GFI -- GROUND FAULT CIRCUIT BREAKER OTHERS LOAD 1900 X 1 = 1900 NA) (OTHER 0 10096) GA - GROUND FAULT CIRCUIT BREAKER TOTAL LOAD = 109219 (VA) * - PROVIDE ISOLATED GROUND TC - PROVIDE 7 -DAY ASTRONOMICAL TIME CLOCK TOTAL LOAD = 64219 (VA) PC - PHOTOCELL CONTROL TOTAL LOAD = 18018 (VA) PC - PHOTOCELL CONTROL TOTAL AMPS. = 131 AMPS. 3 PHASE, 277/480V GFI - GROUND FAULT CIRCUIT BREAKER TOTAL AMPS. = 178 AMPS. 3 PHASE, 120/208V * * - PROVIDE SHUNT TRIP TOTAL AMPS. = 50 AMPS. 3 PHASE, 120/208V * * - PROVIDE SHUNT TRIP LOAD ANALYSIS @ PANEL "A° 120/208V, 3 PHASE, 4WIRE LOAD ANALYSIS @ PANEL "B" 120/208V, 3 PHASE, 4WIRE LOAD ANALYSIS 0 PANEL "Br 120/208V, 3 PHASE, 4WIRE = ,_. ►V _ 0� , °a ^ `= r, `` 28557 ,4/ - --,p > G `�70NAL LOAD DESCRIPTION 0A 0B 0C LOAD DESCRIPTION 0A 013 0C LOAD DESCRIPTION M 0B 0C LIGHTING & LARGEST MOTOR LOAD 12000 12000 12000 LIGHTING & LARGEST MOTOR LOAD 4084 4084 2004 LIGHTING & LARGEST MOTOR LOAD 3248 4408 4518 25% OF LCL & LM 3000 3000 3000 25% OF LCL & LM 1021 1021 501 25% OF LCL & LM 1102 11 1130 65% OF KITCHEN EQUIPMENT 0 0 0 6596 OF KITCHEN EQUIPMENT 7588 7531 6643 6596 OF KITCHEN EQUIPMENT 0 0 0 RECEPTACLE & OTHER LOAD 21373 22186 20660 RECEPTACLE & OTHER LOAD 8680 9550 10112 RECEPTACLE & OTHER LOAD 1440 860 500 TOTAL LOAD (VA) 36373 37186 35660 TOTAL LOAD (VA) 21373 22186 20660 TOTAL LOAD (VA) 5500 6370 6148 AMP PER PHASE 131 134 129 AMP PER PHASE 178 185 172 AMP PER PHASE 46 53 51 ... EXPIRES 4 -17 -2009 '1-7 —A(\ LIGHTING FIXTURE SCHEDULE INTERIOR LIGHTING CONTROL DETAIL EMERGENCY LIGHTING CALCULATION L `131"-6 N d2= x2+ h2 COS 0 = h/d TYPE "BE" = 1200 LUMENS LIGHT FIXTURE SCHEDULE 0 0 O 0 O a SYMBOL TYPE DESCRIPION MANIJFR CATALOG NO. PARTS NO. RNH yT LAMP REMARKS �ELO�M ii /G/ 2 COS0= 1014.14 d = Jx2+ h 2 / 0 A 4 DIA. RECESSU DOWN LIGHT ELATE A4- P400B -P20 35 35W PAR3B LAMP h =1 D' 1 d=V102+102 cos 0= 0.707 d d = 14.14 R CODE ION1p CE %>FPA 7 ®" �� f��+R 2 0�� 0 W b 4 DIA WALL WASHER LIGHT ELATE LV4-MR16 -CP 35 35W MR16 LAMP TO PANEL 2' X 2 FLUORESCENT LIGHT FIXTURE, RECESSED MOUNT RUDD LIGHTING 2X2/32/T8 51 120 3 -17 WATTS 2FT FL LAMP B 2' X 4' FLUORESCENT LIGHT FIXTURE, RECESSED MOUNT WITH 90 MIN. BATTERY PACK RUDD LIGHTING 2X4/32/T8 64 120 2 - 32 WATTS 4Fr FL LAMP 2 9 0 ® PF BE AUTO TIME SWITCH POINT "0" x =10' POINT "P" of TUVAl t' *, 7 1�1 ILO% 0 - FOOT CANDLE CALCULATION: EMERGENCY LIGHT FIXTURE ENCORE EMR12/75W/275 150 120 2 -75W LAMP NORMALLY OFF SYSTEM T /C -1 LIGHTING CONTACTOR • ' E UNDER CABINET UGHT TBD TBD 32 0 1 - 32 WATTS 4FT FL LAMP FC - LUMENS COS 0 x LLF • Cl UH UNDER EXHAUST HOOD UGHT FIXTURE BY HOOD MANUFACTURER -Ip0 120 1-100U LAMPS 7 d2 POINT "P" = 1200 x 0.707 x 0.8 �� SEE PANEL SCHEDULE FOR CIRCUIT & No. OF POLES 0 o // - 3.39 FC (14.14) 2 POINT Q " 1200 x 0.707 x 0.8 = �� .--: oV UNIVERSAL MID. EXIT SIGN W/ WHITE HOUSING & RED LETTER PANEL LTTHONIA UTHONIA'QUANTUM' #LQM-S- W -3-R- 120/277 -EL 120 1BD EXIT (0-2 HRS OVERRIDE) LABELED "LIGHTING OVERRIDE SWITCH". LOCATE SWITCH SO THAT PERSON USING — 6.78 FC (10) 2 TO EMERGENCY LT AND /OR DUI THE DEVICE CAN SEE THE LIGHTING SIGN (SEE LIGHTING PLAN) CONTROLLED. REFERENCE NOTE d2 = x 2+ h 2 cos 0= h /d TYPE "E" = 1050 X2 = 2100 LUMENS // T /C: AUTO TIME SWITCH SHALL BE #E1-175C SPDT BY 1NTERMATIC", TORK #7000 SERIES OR EQUAL C: LIGHTING CONTACTOR 120V COIL, 30A, POLE NO. OF POLE AS REQUIRED. LIGHTING CONTACTOR SHALL BE SQUARE D '1-G" SERIES OR EQUAL PROGRAMMABLE GENERAL NOTES O d = Y x2+ h 2 cos 0 = 12/16.97 Y h =12' d — 12 2+12 2 cos 0 = 0.59 d= 16.97 d '`_ // // 1 TIMECLOCK SHALL BE CERTIFIED AS REQUIRED BY 2005 BUILDING ENERGY STANDARD SEC, 119 2. REFER TO MANUFACTURERS MANUAL FOR EXACT WIRING REQUIREMENTS. a REFER TO PANEL SCHEDULE FOR LIGHTING LOAD. 4.11MECLOCK SHALL BE 365 -DAY PROGRAMMABLE WITH 10 HOUR BATTERY BACK-UP. 5. TENANTS LIGHTING AND LIGHTING CONTROLS SHALL COMPLY WITH WASHINGTON STATE NON - RESIDENTIAL ENERGY CODE 6. STOREFRONT SIGNAGE AND UGH TING TIME CLOCKS SHALL BE SET TO MALL'S OPERATING HOURS. POINT "Q" x =12' POINT "P" FOOT CANDLE CALCULATION: / LIGHT FIXTURE SCHEDULE KEYNOTES : 0 SEE LIGHTING PLAN AND ELECTRICAL PANEL SCHEDULES FOR CIRCUITING AND VOLTAGE INFORMATION Q ONLY UL APPROVED EQUAL SUBSTITUTIONS ARE ACCEPTABLE 0 SEE ELECTRICAL PLANS FOR FIXTURES EQUIPPED W/ 90 MINUTES MINIMUM EMERGENCY BATTERY PACK 0 PROVIDE ENERGY SAVING BALLAST. FOR EMERGENCY LIGHTING 0 ELECT. CONTRACTOR TO FURNISH & INSTALL UGHT FIXTURE, LAMP, POWER FEEDS, CONNECTORS & MISC, HARDWARE AS READ. FOR INSTALLATION. 0 NO SUBSTITUTION FOR LIGHT FDC JRES AND LAMPS SPECIFIED IS GRANTED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT. 0 SEE REFLECTED CEUNG PLAN, ARCHITECTURAL PLANS & DETAILS FOR MORE INFORMATION. 06 VERIFY COMPATIBILITY OF LAMP SPECIFIED WITH THE UGHT FIXTURE & BALLAST TYPE PROVIDED BY THE MANUFACTURER PRIOR TO BIDDING OR ORDERING - NOTIFY THE ARCHITECT OF ANY DISCREPANCIES. 0 LIGHT FIXTURE OR LAMP USED INSIDE THE FIXTURE SHALL BE SHATTERPROOF - AS REQUIRED FOR FOOD SERVICE/ RESTAURANT USE PER LOCAL CODES - G.0 TO VERIFY FC = LUMENS x COS 0 x LLF d2 P „ 2100 x 0.59 x 0.8 POINT = 3.44 FC - (16.97) 2 2100 x 0.59 x 0.8 POINT "Q" FC -- - 6.88 (12) 2 MAR 13 20O6 PERMIT CENTEh Elpilw 0 p a r z 0 7 W C ky�s ISSUED FOR PERMIT JUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - DATE DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 2.O.DWG SHEET TITLE: FIXTURE SCH., PANEL SCH. Sc LIGHTING CONTROL DETAIL KENN BUTTS A.I.A. Rutts 11111 Kenneth Architect r1<««« ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL (Sc WESTFIELD FINAL SUBMITTAL DATE 01 -09 -08 02 -11 -08 03 -06 -08 BELL CANYON, CA. 91307 TEL. (818) 999 4272 ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ky�s ISSUED FOR PERMIT JUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 2.O.DWG SHEET TITLE: FIXTURE SCH., PANEL SCH. Sc LIGHTING CONTROL DETAIL KENN BUTTS A.I.A. Rutts 11111 Kenneth Architect . . I. 124 STAOFCOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E—MAIL YASHAVANTCCOX -NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 2.O.DWG SHEET TITLE: FIXTURE SCH., PANEL SCH. Sc LIGHTING CONTROL DETAIL SCALE: AS NOTED SHEET NUMBER: E -2.O GENERAL NOTE: ky's ISSUED FOR BIDDING DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION 4 _ 1 9 E 0 DESIGNED BY: - DRAWN BY: - DATE ELECTRICAL SYMBOLS Kg) JUNCTION BOX AT WALL a CQ JUNCTION BOX ABOVE FLOOR JQ JUNCTION BOX AT CEILING JUNCTION BOX INSTALLED IN EQUIPMENT DUPLEX CONVENIENCE OUTLET -e- DUPLEX CONVENIENCE OUTLET DATE: 03.06.2008 1. VERIFY LOCATION OF ALL OUTLETS TO KITCHEN EQUIPMENT SUPPLIER BEFORE ROUGH -IN. ALSO VERIFY REQUIREMENTS OF EACH PIECE OF EQUIPMENT, FURNISH AND INSTALL AS REQUIRED. 2. SEE MECHANICAL DRAWINGS FOR HVAC CONTROL REQUIREMENTS. FURNISH AND INSTALL AS INDICATED. 3. GENERAL CONTRACTOR MUST COORDINATE ALL ELECTRICAL WORK SHOWN ON THE PLAN WITH ARCH. AND KITCHEN FOOD SERVICE EQUIPMENT PLANS. NOTIFY THE ARCHITECT OF ANY COORDINATION ISSUES ENCOUNTERED PRIOR TO START OF THE WORK 4. ALL COOKING EQUIPMENT AND CONVENIENCE RECEPTACLES LOCATED UNDER THE FOOTPRINT OF EXHAUST HOOD EQUIPPED WITH ARE SUPPRESSION SYSTEM SHALL BE EQUIPPED WITH SHUNT -TRIP CONTROL AND INTERLOCKED WITH ARE SUPPRESSION SYSTEM, 5. ALL KITCHEN HOODS FIRE SUPPRESSION SYSTEMS SHALL BE CONNECTED TO THE LANDLORD'S FIRE ALARM SYSTEM. ANAL CONNECTION TO THE LANDLORD'S ARE ALARM SYSTEM MUST BE BY LANDLORD'S APPROVED FIRE ALARM CONTRACTOR AT TENANTS EXPENSE KEYNOTE LEGEND: V■ Kenneth Architect <aaaaaaa< L. 124 STAGECOACH ROAD BELL CANYON, CA. 91307 ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL 1 SINGLE CONVENIENCE OUTLET go SINGLE PURPOSE POWER OUTLET (230V) @ SINGLE PURPOSE POWER OUTLET b' VAPORPROOF LIGHT III (FURNISHED WITH EQUIPMENT) SWITCH - DROP CORD ASSEMBLY PULLBOX - + 29 7 .-,, + A /j %; _ ■ .r -- SWITC I-1 BANK r. 16 co + 1 2 E -MAIL YASHAVANTOCOX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX < _ - - - -- _ - - -TE _- __ - -.- <> PROVIDE J -BOX IN ACCESSIBLE LOCATION AND CONNECT TO SIGN AS PER CODE REQUIREMENTS. VERIFY REQUIREMENTS WITH THE ARCHITECT AND SIGN CONTRACTOR PROVIDE DEDICATED NEUTRAL AND GROUND FOR ALL SIGNS. CONTRACTOR SHALL PROVIDE LIGHTING CONTROL CONTACT AND TIMER. O POWER SUPPLY FOR COMPUTER AND CASH REGSTER SHALL BE WITH ISOLATED GROUND AND ORANGE RECEPTACLE 3O PROVIDE 1u CONDUIT FOR TELEPHONE/DATA CABLING WITH CAT. 5 CABLES AND ROUTE BACK TO TELEPHONE BACKBOARD. VERIFY EXACT LOCATION AND QUANTITY .0 GENERAL CONTRACTOR SHALL INTERCEPT EXISTING CONDUIT STUBBED INTO TENANT SPACE AND EXTEND TO TENANT TELEPHONE BACKBOARD. CONTRACTOR TO FIELD VERIFY EXACT LOCATION AND SIZE OF CONDUIT BEFORE BIDDING O5 CONTRACTOR SHALL VERIFY WITH KITCHEN EQUIPMENT CONSULTANT THE TYPE OF RECEPTACLE REQUIRED FOR EACH EQUIPMENT, VERIFY ALL OUTLETS WITH MANUFACTURER SPECIFICATION. i<> PROVIDE 3/4" CONDUIT FOR LOW VOLTAGE CONNECTION BETWEEN OUTDOOR UNff AND THERMOSTAT CONTROLLER. 7 60AS, 6OAF, 3P, NEMA 3R ENCL 600V. PROVIDE 1 -1/4"C 3#4 CU + 1#6 GND. O 8\ NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. KEEP 3 FEET CLEARANCE IN FRONT OF ELECTRICAL PANELBOARD AND EQUIPMENT. 4 TIME CLOCK CONTROLLER: PROVIDE INTERLOCK WRING FROM OVERRIDE SWITCH TO TIME CLOCK CONTROLLER INSTALL OVERRIDE SWITCH AT SWITCH BANK. 10 FOR EXACT LOCATION OF KITCHEN EQUIPMENT RECEPTACLE AND POWER REQREMENTS REFER TO KITCHEN DRAWING SHEET F -1 & F -2 11 CONDENSING UNIT ON ROOF (VERIFY LOCATION). 3/4 "C, 2 #10 + 1 #10 GND., 30AS, 25AF, 2P, NEMA 3R ENCL OGAS SOLEND VALVE CONTROL COORDINATE LOCATION WITH PLUMBING CONTRACTOR VERIFY EXACT LOCATION IN HELD. O CONTRACTOR SHALL PROVIDE INTERLOCKING CONTROL WIRES AND CONDUIT TO SHUT -OFF ALL ELECTRICAL UNDER HOOD WHEN SYSTEM IS ACTIVATED, PROVIDE INTERLOCKING CONTROL WIRES BETWEEN SYSTEM CONTROL BOX AND SHUNT TRIP BREAKER AT ELECTRICAL PANELBOARD. ALL INETRLOCKING SYSTEM SHALL BE PROVIDE AS PER SYSTEM REQUIREMENTS. Il �■ I 1 ALARM PLAN NOTES 1 ALL FIRE ALARM SYSTEMS BY OTHERS. 2 INSTALLATION OF ARE ALARM SYSTEM SHALL BE UNDER A SEPARATE PERMIT. ALL REQUIRED FIRE ALARM DEVICES, CONDUITS, WIRES, BACK BOXES, ETC, SHALL BE INSTAI I FO AT TENANT'S EXPENSE UNDER A + 12 ill � .� �1` " •1A � , I>t \ _ 5k �� �� , ` �� „8„_7,13 \ lrti,V \ >, / ,/ , , �/ g 1 1,B11J �� „ „ g -3 TINT,- "B111-7 — �. TELEP NE BACKBOARD + qi ' ��,� I, .. �' (� 11811_21 2 8 �- -11 VIA �?WO r�I `; - ��" * U ►�+,'�► � SW. BA a,� ■r�.� � � �I SEPARATE PERMIT BY MALL FIRE/LIFE SAFETY CONTRACTOR �. `r ► +,'� 7 • +�.�_ ►. SW. BANK 1li. 4 k �'+►�n. / , .l ,�� :�;+ / 1 4 + ,c �■ `It_ '' .r`�, / »B -111_9 VIA "'"� � r ` r I IME GCS CONTROL » » 81 -6 11TA , , „ , B KTCHEN EQUIPMENT NOTE 1 FOR KITCHEN EQUIPMENT SCHEDULE, NOTES AND ADDITIONAL WORKS REFER TO KITCHEN PLANS.. „ 44 4a; SW, BANK h �, 11 11 B - 14 CEILING MOUNTED J -BOX FOR EXHAUST HOOD. GENERAL `/ CONTRACTOR TO EXTEND CONDUIT AND WRES DOWN TO HOOD AND MAKE FINAL CONNECTION TO HOOD LIGHT, PROVIDE WRING AND HOOD WALL SWITCH MOUNTED AT SWITCH BANK. VERIFY EXACT LOCATION IN HELD. SEE KITCHEN DRAWNG FOR EQUIPMENT INTERLOCKING REQUIREMENTS, 15 NEW TRANSFORMER SEE ARCHITECTURAL SHEET FOR MOUNTING DETAILS, ,� I a PROVIDE 4 BOX, V2' CONDUIT AND WIRES FOR REMOTE PULL STATION AND INTERLOCK WITH ARE SUPRESSION SYSTEM. COORDINATE LOCATION WITH THE ARCHITECT. VERIFY INTERLOCKING SYSTEM AND QUANTTTY OF REMOTE PULL STATION WITH FIRE SUPPRESION SUPPLIER /CONTRACTOR H BANK NFl URATI 1? SWITC Co G ON , O P " CKT #9 : SWITCH Yr". CKT #11 ;SWITCH �', k". " CKT #6: SWITCH "oil (OVERRIDE SWITCH), .0 J-BOX FOR FIRE SUPPRESSION SYSTEM. VERIFY EXACT LOCATION IN HELD. CONTRACTOR SHALL PROVIDE INTERLOCKING CONTROL WIRES AND CONDUIT TO SHUT -OFF AU_ ELECTRICAL UNDER HOOD WHEN SYSTEM IS ACTIVATED, PROVIDE INTERLOCKING CONTROL WIRES BETWEEN SYSTEM CONTROL BOX AND SHUNT TRIP BREAKER AT ELECTRICAL PANELBOARD. ALL INETRLOCKING SYSTEM SHALL BE PROVIDE AS PER SYSTEM REQUIREMENTS. 12 ► 's% / _ f 11B1J1�5 � l,� I 5 ~Ily �; ,� . • l�" U • Ill '�� 1 11 B -5 76' 61 I • ��� �! 1$ i �� t `' l ��ill rtr�I + �+���, � � CI 8 ��� s +12" I 1 ����; �) 1 : 1 lit.!--: +I�' : 18 ` ��'-;t Ob oet f i �;, ` 1 `�;�4' �r l�1__ ' ��+;. ■{1 11411,----------_,-__;.... ` 1 1010'441 >�� � � r•~`: 1 1 �•�,; �• 1 . y �.; r+ +� STUB �� �► O �� DN 42 „ „_ "B"-1 oil n (N) PANE , 120/208V. _ • �$ i �,�+�„ 1 �� ' ■ -I-4S t -,� ► i r Q, I: r_4 4t4i, � ► ,,,,, 30 Ut4I =_ ��� , ►—.._. ___ 1111 .,...ter. .. ,-- ., . E `I ��'+ '���,:. -- ':�'� ID �`;..1 ; + 12 ' TheMM•:,■� ► " •V >r . \ I f II ���; 7 • ,�,� +� >♦ �I'4tiii%\ .wri 'I %AA. � ` DRY TYPE TRANSFORMER 75KVA, 480V- 12D/208V, Moll JJF'� l�/i7f G /1ti�- / - Afg,04/�% * 1 x~ r CB1 J1 I� l' r ,l'� 3 PHASE, 4W. /�flJ �-r�i� �'1.il% '� ODE -- • c CE �FP� 2 Q � �► �� �aN CI BMW *44 ? +. r7 ��a STUB ' =�`' ll .. ���� \TT,N\HI', �_ �' 4S �� �1'��1', '� B —'� ' \ i 16 ,fir° 30 t� �b/!� 1 1 - UP — r l N IV a \ l > ■ I� 11 (N) PANEL ��� --��, I -> + 12 °° }�� t� % II 12O/2D8V, 3P I 3 2 .� ll l" ► [* +48" 1 • ' a l /, 5 l -� `, �, 11 11_ \ 41 ttI\ sS i / E 1 I II EQUPMENT AND UTUTY SCHEDULE \ \ 8 / t fir, "" � » » B -2,4 .�R •• i EQUIPMENT ELECTRICAL ITEM DESCRIPTION QTY MANUFACTURE/MODEL NO, VOLT. KW AMPS HP PH CONhl REMARKS I �� l 'a�', I ,� \,. B -� _ -- l + f I : *w , 69 Br DIRECT OUTLET 10 OFFICE FURNITURE 1 LOT BY OWNER 120 * 1 X VERIFY W /OWNER \ ".� 12 U/C HTD. CABINET 2 ALTO SHAAM #750 -SAS 1 U 120 8.6 1 X t \ 11 ll l r 3 i y ; 1 • • 14 WORKTABLE 1 CUSTOM ST/ST :� TYPIC • L ll ll /� � ■ �jr� l 11 114 �: l t l 1 l 1 ll � 1111,Villifillli + Y - fir _ 16 U/C HID. CABINET 1 ALTO SHAAM #750 -S/STD 120 8.6 1 X 17 HOT FOOD WELL 1 WELLS #HT-300AF 208 13D 1 X �r 18 REFRIGERATED TABLE 1 DELFIELD #D4472N -30M 120 120 1 X SELF - CONTAINED 23 HEATED SHELF 1 HATCO #GRSB -24-F 120 35 1 X „A „, i:= r• s '. 257 r. % 'QF r,32 26 CASH REGISTERS 3 BY OWNER 120 5A 1 X DEDICATED CIRCUIT (N)PANEL - 277r48OV 8P ' 28 PIZZA OVEN HOOD 1 CAPTIVE AIR 120 3.0 1 X HOOD LIGHTS. WIRE THRU SWITCH •`y` i� 1 r�� �1 29 PIZZA OVEN 1 WOODSTONE #4343 230 0.4 1 X II TYPIC •L J + 11.1) w .....) ;, r i(!r I ._ 30 FOOD FINISHER 2 HATCO #TFW -4518 208 63 1 X +48” 31 REFRRIGERATED STAND 1 DELRELD #F2962C 120 8.0 1 X SELF - CONTNED REEF ERATED TABLE 1 DELHELD #4427N -9M 120 65 1 X SELF- CONTAINED 35 EXHAUST HOOD 1 CAPTIVE AIR 120 5A 1 X HOOD LIGHTS. WIRE THRU SWITCH 36 EXHAUST FAN SYSTEMS 1 LOT BY GEN. CONT. 208 * 3 X VFY, W /HVAC CONTR � Ei{t EItES 4 -,7 X0((19 37 FRYER 2 FRYMASTER #FP247 120 10 1 X ---2-j-7( ^ 49 41 RRE SUPPRESSION SYSTEM 1 ANSUL #R -102 PART OF ITEM #35 4. ( r----0-(5 I k 42 WALK -1N COOLER 1 DURACOLD 120 8.0 1 X BLOWER COIL & LITS 44 EXHAUST HOOD 1 CAPTIVE AIR 120 3.0 1 X HOOD LIG ITS. WIRE THRU SWITCH 45 FIRE SUPPRESSION SYSTEM 1 PART OF TEEM #35 "A"-2,44 49 PREP TABLE W/SINK 1 CUSTOM ST /ST 120 115 1 X WALL MOUNTED DCO 55 SODA SYSTEM 1 LOT BY SODA VENDOR _ 57 WORKTABLE 1 CUSTOM ST/ST 120 118 1 X WALL MOUNTED DCO llrl ,___ < 61 CE MACHINE 1 HOSHIZAKI # KM- 501MAH 120 13A 1 X � VI II♦ � 65 REFRIGERATION SYSTEM 1 FOR ITEM #42 208 200 1 X 68 SODA ACE DISPENSER 1 BY SODA VENDOR 120 5A 1 X CARBONATOR „� I n 7 lb 69 TEA MAKERS 2 BUNN #TU3 120 14.8 1 X Y ii, "' 7,___ CFI ppij- REC � f F PIAR 13 2008 PERMIT CENTENT ER KEC. - KITCHEN EQUIPMENT CONTRACTOR G.C. - GENERAL CONTRACTOR OWN. - OWNER P.C. - PLUMBING CONTRACTOR, E.C. - ELECTRICAL CONTRACTOR, 0 - OUTLET, C.O. - CONVENIENCE OUTLET, DIRECT - DIRECT CONNECTION, I. W. - INDIRECT WASTE, FD - FLOOR DRAIN F,S. - FLOOR SINK RD. - ROOF DRAIN, F,T. - FLOOR TROUGH W E R, To All Contractors Requred note for bidolng and hstallatiore All contractors (general contractor as well as all sub-contractors) bidding and awarded to construct this facility are responsible to verify all equipment furnished and supplied and installed at this site, The equpment utility (gas, water, sewer, vent, electrical, building mechanical systems. duct connections, exhaust corrections, security, fie alarm, data, phone, etc) connection must be verified before biddng. These information are not Gaited to point of connection, Locations, type of corrections. number of convections, and coordination with r other trades. The contractors shall be responsible for reading the equipment specification book as part of the construction documentation. The equipment will include all equipment purchased or furnished or installed by any one. All utility connections and the locations must include all eipm>ent as required by the utll ty company as well as local codes or the shopping center/Mall requJirements. Contractor to verify all requirements before bid. The most stringent requirement shall apply even if not detailed The contractors are responsible to request for verification of all Mall or Shopping Center requkements as well as any other local /State/Federal requirements, The contractor shall insure all exisijr g systems are verified and functional. Contractor to verify the placement of new equipment are available. All equipment furnished to the contractor as well as purchased by the contractor must be accompanied with full submittal process and Engineers' approval The contractor shall follow all installations per local and State Codes and any devotion from codes even if not detailed in plans, any field correction must be performed by the contractor at no cost to the owners The contractors are responsible to request for all out sheets for the equipment and if the equipment ftrn shed differed from the cut sheets, the contractor shall adjtnat the installation accordingly. All ceordiretk n and adjustment among all trades must be performed by the General Contractor. All coordination and the distr ltion of responsibility for the site is by the general contractor. All bids must be for full and complete installation and complete functional and operational will be part off bbl for fully functional and complete installation gas requured plans and specification penetrations, well as b attachments, supports, and �other nd al requirements irrteriocki and interfaces sub- contractors such as smoke or duct detectors within HVAC units and with an trades not shown on these dra ' such as security system, fre alarm system must be well coordnate du tirg bid. The Contractor is responsible for all of above requkements and must include all provisions into the bid and installation All existing installations & connections done by others are not part of the sccpe of this project If the installation, connections, materials & equipment are not to code or are unsafe, the owner of the buicfig shall be contacted and all corrections to existing work shall be done under separate contract Engineer is not responsble for any existing conditions a work previously done by others. 1 WATER 36 KW, H -AT A 4 ��, ELECTRICAL POWER PLAN I�IQI�TI" A • ■ '- SCALE : 1/2' =1 05 Mir ..► 2. iii REVISION 1 ky's ISSUED FOR BIDDING DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - DATE REVIEWED BY: - DATE: 03.06.2008 KENN BUTTS A•I•A• Butts V■ Kenneth Architect <aaaaaaa< L. 124 STAGECOACH ROAD BELL CANYON, CA. 91307 ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINAL SUBMITTAL FAX. (818) 999 4321 DATE 01 -09 -08 02 -11 -08 03 -06 -08 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 ISSUED FOR APPROVAL ky's ISSUED FOR BIDDING DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 KENN BUTTS A•I•A• Butts V■ Kenneth Architect SHEET TITLE: ELECTRICAL POWER PLAN L. 124 STAGECOACH ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANTOCOX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 3.13.DWG SHEET TITLE: ELECTRICAL POWER PLAN SCALE: 1/4"=1"—O" SHEET NUMBER: E -3.0 GENERAL NOTE: 1. VERIFY LOCATION OF ALL UGHT FIXTURE BEFORE ROUGH -IN. FURNISH AND INSTALL AS REQUIRED. 2. ALL LIGHTING IN FORWARD SELLING AREA MUST BE INCANDESCENT WITH LOW IRON TEMPERED GLASS SAFETY LENS, PER FOOD PREPARATION AND LOCAL CODES, ON SEPARATE CIRCUIT WITH A 7 DAY TIME CLOCK SET TO MAWS OPERATING HOURS. FOOT -CANDLE LEVEL, AT COUNTER HEIGHT, MUST BE AN AVERAGE OF 50 MAINTAINED. a EMERGENCY UGHTING SHALL BE FULLY RECESSED IN THE SELUNG AREAS. NO SURFACE MOUNTED TYPE IS ALLOWED. TYPICAL 4. SEE MECHANICAL DRAWINGS FOR HVAC CONTROL REQUIREMENTS. FURNISH AND INSTALL AS INDICATED. KEYNOTE LEGEND: SWITCH BANK CONFIGURATION : PANEL "B1" CKT #1: SWITCH "c". CKT #3 : WITCH "d", "O, "P', "g°. PANELS" CKT #26 : EF -1 SWITCH "4.' CKT #32 : EF -2 SWITCH "m" CKT #34 : EF -3 SWITCH 'tt" -SWITCH BANK D NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE FI FCTRICAL EQUIPMENT. KEEP 3 FEET CLEARANCE IN FRONT OF ELECTRICAL PANELBOARD AND EQUIPMENT. TIME CLOCK CONTROLLER PROVIDE INTERLOCK WRING FROM OVERRIDE SWITCH TO TIME CLOCK CONTROLLER INSTALL OVERRIDE SWITCH AT SWITCH BANK. EMERGENCY LIGHT TYPE "E" SHALL BE NORMALLY OFF, HOOD LIGHTS BY EXHAUST HOOD MAUFACTURER REFER TO SHEET E -3.O FOR CIRCUIT ASSIGNMENT. VERIFY REQUIREMENTS WITH HOOD MANUFACTURER 3/4"C, 3#12 + 1#12 GND., 30AS, 20AF, 3P, NEMA 3R ENCLOSURE WITH COMBINATION MOTOR STARTER, WEATHER PROOF. 3 /4"C, 3 #10 + 1 #10 GND, 30AS, 30AF, 3P, NEMA 3R ENCLOSURE WITH COMBINATION MOTOR STARTER, WEATHER PROOF. 1"C, 3#8 + 1#8 GND, 60AS, 45AF, 3P, NEMA 3R ENCLOSURE WITH COMBINATION MOTOR STARTER, WEATHER PROOF. PROVIDE 3/4" CONDUIT AND CONTROL WIRES TO RESPECTIVE THERMOSTAT. PROVIDE 3/4" CONDUIT AND CONTROL WIRES TO RESPECTIVE SYSTEM, SEE MECHANICAL EQUIPMENT SCHEDULE FOR INTERLOCKING REQUIREMENTS. REFER TO KITCHEN DRAWINGS FOR ADDITIONAL WORK REQUIREMENTS. ROOF MOUNTED RECEPTACLE, GFCI, WP, MOUNTED ON AC FRAME KITCHEN EQUIPMENT NOTE 1 FOR KITCHEN EQUIPMENT SCHEDULE, NOTES AND ADDITIONAL WORKS REFER TO KITCHEN PLANS. FIRE ALARM PLAN NOTES: 1. ALL FIRE ALARM SYSTEMS BY OTHERS. 2. INSTALLATION OF FIRE ALARM SYSTEM SHALL BE UNDER A SEPARATE PERMIT. ALL REQUIRED FIRE ALARM DEVICES, CONDUITS, WIRES, BACK BOXES, ETC. SHALL BE INSTALLED AT TENANT'S EXPENSE UNDER A SEPARATE PERMIT BY MALL FIRE/LIFE SAFETY CONTRACTOR To All Contractors: Required note for bidding and hstalatiorx All contractors (general contractor as well as all sub -- contractors) bidding and awarded to construct this facility are responsible to verify all equipment finished and supplied and installed at this site. The eqL m0nt utility (gas, water, sewer, vent, electrical, building mechanical systems. duct connectbr►s, exhaust connections, security, fire alarm, data, phone, etc.) connection must be verified before biddng. These information are not limited to point of comection, locations, type of connections. number of connections, and coordination with other trades. The contractors shall be responsible for reading the equipment specification book as part of the construction documentation. The equipment will include all equipment purchased or furnished or installed by any one. All utility corrections and the locations must include all equipment as required by the utility company as well as Kcal codes or the shopping center/Ma]I requirements. Contractor to verify all requirements before bid. The most stringent requirement shall apply even if not detailed The contractors are responsble to request for verification of al Mal or Shopping Center requirements as well as any other local/ State /Federal requirements. The contractor shall insure all existing systems are verified and functional Contractor to verify the placement of new equipment are available. All equipment furnished to the contractor as well as purchased by the Contractor must be accompanied with full submittal process and Engineers' approval. The contractor shall follow all installations per local and State Codes and any deviation from codes even if not detailed in plans, any field correction must be performed by the contractor at no cost to the owners. The contractors are responsible to request for all cut sheets for the equipment and if the equipment furnished differed from the cut sheets, the contractor shall adjust the installation accordngly. All coordination and adjustment among all trades must be performed by the General Contractor. All coordination and the distribution of responsibility for the site is by the general contractor. All bids must be for full and complete Installation and complete functional and operational equipment and systems, All accessories and peripherals wires, conduits, pipes, connections, roof penetrations, attachrrnents, supports, and any other requirements will be part of bid for fury functional and complete installation as requred by plans and specifications as well as Kcal requirements. All controls, and al interiocl ing and ir terfaces among sub - contractors such as smoke cr duct detectors withh HVAC units and with all trades not shown on these drawings such as security system, fre alarm system must be well coordinate during bid. The Contractor is responsble for all of above requirements and must include all provisions into the bid and installation All existing installations & connections done by others are not part of the scope of this project If the installation, connections, materials & equipment are not to code or are unsafe, the owner of the bulking shall be contacted and al corrections to exsthg work shall be done under separate contract Engineer is not responsble for any existing conditions or work previously done by others. +12, -2„ A.F.F- TIME CLOCK CONTROL MU Wag OUTER y n tx w rLr / DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON AIRFLOW DESIGNED BY: - DRAWN BY: - CHECKED BY: - DATE SCI-IMGE • KENN BURS A.I.A. Butts 00■ GR 9B" -37,39,41 'BF- 8,10,12 40 6 "B " -34 "B'-2628,30 w.. C�> MOTOR RATED SWITCH (TYFICAL) PARTIAL ELECTRICAL ROOF PLAN SCALE : 114' =1'-0' 5 TON E,XpJRES 4 -17 -2009 ELECTRICAL LIGHTING PLAN SCALE : 1/2' = P -p ELOS2Mi RECEIVED MAR 13 2008 PERMIT CENTER REVISION 1 k�i" sS ISSUED FOR PERMIT DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - DATE DATE: 03.06.2008 JOB NUMBER: 07936 KENN BURS A.I.A. Butts gir Kenneth Architect r<KKKKKKK L . 124 STACi-COACH I ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 ISSUE HEALTH DEPARTMENT SUBMITTAL PERLIMINARY SUBMITTAL PLAN DEPARTMENT SUBMITTAL & WESTFIELD FINIAL SUBMITTAL I DATE 01 -09 -08 02 -11 -08 co O I M 0 DAVIS, CA 95616 E -MAIL YASHAVANT©COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK k�i" sS ISSUED FOR PERMIT DUTHCENTER MALL, SPACE # FC -2 TUKWILA, WASHINGTON ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 KENN BURS A.I.A. Butts gir Kenneth Architect SCALE: 1/4"=1"-o" L . 124 STACi-COACH I ROAD BELL CANYON, CA. 91307 TEL. (818) 999 4272 FAX. (818) 999 4321 Y V KULKARNI, P.E. (MECHANICAL AND ELECTRICAL) 39371 SPANISH BAY PLACE DAVIS, CA 95616 E -MAIL YASHAVANT©COX.NET FOR PROJECT COORDINATION CONTACT PROJECT MANAGER KIM KIMIAGAR 310 576 1553 PHONE 310 576 1569 FAX ISSUED FOR APPROVAL ISSUED FOR PLAN CHECK ISSUED FOR BIDDING ISSUED FOR PERMIT ISSUED FOR CONSTRUCTION ISSUED FOR: DESIGNED BY: - DRAWN BY: - CHECKED BY: - REVIEWED BY: - DATE: 03.06.2008 JOB NUMBER: 07936 FILE #: E- 4.4.DWG SHEET TITLE ELECTRICAL LIGHTING AND ROOF PLAN SCALE: 1/4"=1"-o" SHEET NUMBER: E -4.O