Loading...
HomeMy WebLinkAboutPermit EL08-0260 - WESTFIELD SOUTHCENTER MALL - LEARNING QUEST TOYSLEARNING QWEST TOYS 2426 SC MALL 07.23 -08 ELO8-260 Parcel No.: Address: Suite No: Cityillf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 6364200010 2426 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: EL08 -260 05/07/2008 01/12/2009 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: LEARNING QUEST TOYS 2426 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA KEITH SMITH 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: Phone: 206 713 -4076 Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: PROVIDE NEW ELECTRICAL SERVICE, PANELS, TRANSFORMER, .AND LIGHTING. Value of Electrical: Type of Fire Protection: $26,000.00 SPRINKLERS /AFA Electrical Service provided by: Fees Collected: National Electrical Code Edition: PUGET SOUND ENERGY Permit Center Authorized Signature: �k $809.50 2005 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of construction or Signature: J Lz-yrAiuk 1106kre_ ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating ormance of work. I am authorized to sign and obtain this electrical permit. Print Name: Date: 12q�� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -260 Printed: 07 -23 -2008 CitAf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tulcwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2426 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -260 Issue Date: 05/07/2008 Permit Expires On: 11/03/2008 Tenant: Name: WESTFIELD - VANILLA BOX Address: 2426 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 713 -4076 Address: 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: PROVIDE NEW ELECTRICAL SERVICE, PANELS, TRANSFORMER, AND LIGHTING. Value of Electrical: $25,000.00 Fees Collected: $615.00 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: Dni c9-6 0`D I hereby certify that I have read and aced this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie w whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the performance of work. I am authorized to sign and obtain this electrical permit. Signature: 01UJ& t, Date: 051 br1 ID 8 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -260 Printed: 05 -07 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2426 SOUTHCENTER MALL TUKW LEARNING QUEST TOYS Permit Number: Status: Applied Date: Issue Date: EL08 -260 ISSUED 03/17/2008 05/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Odrn� UN(T)/w Wv,.r� doc: Cond -Elec EL08 -260 Printed: 07 -23 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2426 SOUTHCENTER MALL TUB:W WESTFIELD - VANILLA BOX Permit Number: Status: Applied Date: Issue Date: EL08 -260 ISSUED 03/17/2008 05/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: MIN UC/ Date: IV Print Name: t V\\CUVL doc: Cond -Elec EL08 -260 Printed: 05 -07 -2008 Site Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tkwila. wa. us Tenant Name: Ail f W r 1, �. v ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Property Owners Name: Mailing Address: Name: Mailing Address: Ki g o Assessor's Tax No.: 4,3612e -,oew Suite Number: 20th C Floor: 2-t.,40, New Tenant: T Yes ❑..No i City State Zip E -Mail Address: I")V ► l l 1 V` (W y V V L 1 G�J . (f Y 4' Company Name: Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip Valuation of Project (contractor's bid price): $ Scope of Work (ple a provide detailed info Ae, ion): Will service be altered? Type of Use: Type of work: ❑ Yes ❑ No fe,iat( Adding more than 50 amps? ❑ No ❑ New ❑ Addition ❑ Service Change ❑ Remodel ;,Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Pronertv Served bv: uget Sound Energy ❑ Seattle City Light H: Applications\Forms- Applications On lineal -2007 - Electrical Pemut Application.doc bh Page 1 of 2 • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) El Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Camivals $75.00 Number of concessions $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: �IyA�♦ ��� 11L� Day Mailing Address: t W� (/i iNti( J, City IDate Application Accepted: 0791 ti- ( ,- s4 I Date Application Expires: H:Wpplications\Fonns- Applications On L4n64 -2007 - Electncal Permit Application.doc bh VI Page 2 of 2 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2426 SOUTHCENTER MALL TUKW LEARNING QUEST TOYS RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -260 ISSUED 03/17/2008 05/07/2008 Receipt No.: R08 -02713 Initials: WER User ID: 1655 Payee: Payment Amount: $78.50 Payment Date: 07/23/2008 09:26 AM Balance: $0.00 SME OF SEATTLE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21199 78.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 74.40 4.10 Total: $78.50 doc: Receiot -06 Printed: 07 -23 -2008 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us 6364200010 2426 SOUTHCENTER MALL TUKW WESTFIELD - VANILLA BOX RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -260 ISSUED 03/17/2008 05/07/2008 Receipt No.: R08 -02276 Initials: User ID: Payee: WER 1655 Payment Amount: $58.00 Payment Date: 06/24/2008 03:03 PM Balance: $0.00 SME INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21154 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 4049 06/24 9711 TOTAL 406.00 \`6' doc: Receiot -06 Printed: 06-24 -2008 Parcel No.: 6364200010 Address: Suite No: Applicant: WESTFIELD - VANILLA BOX • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us 2426 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -260 ISSUED 03/17/2008 05/07/2008 Receipt No.: R08 -02173 Initials: WER User ID: 1655 Payment Amount: $58.00 Payment Date: 06/18/2008 01:10 PM Balance: $0.00 Payee: SME INC OF SEATTLE TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21146 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 3778 06/18 9711 TOTAL 5800 doc: Receipt -06 Printed: 06-18 -2008 City o?Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01513 Initials: WER User ID: 1655 Payee: SME, INC. OF SEATTLE Payment Date: 05/07/2008 Total Payment: 1,968.00 SET ID: 0507 SET NAME: WESTFIELD VANILLA BOXES SET TRANSACTIONS: Set Member Amount ITENTM"01 492.00 EL08 -262 492.00 EL08 -263 492.00 EL08 -354 492.00 TOTAL: 1,968.00 TRANSACTION LIST: Type Method Description Amount Payment Check 21088 1,968.00 TOTAL: 1,968.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,968.00 TOTAL: 1,968.00 2106 05/07 9711 TOTAL 1968.00 Doc: RECSETS -06 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http.• //i4ww. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -00793 Initials: JEM User ID: 1165 Payee: ERIK 5 BARTH Payment Date: 03/17/2008 Total Payment: 1,125.44 SET ID: S000000982 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -142 862.94 Eh08 -26'0 123.00 M08 -081 101.50 PG08 -083 38.00 TOTAL: 1,125.44 TRANSACTION LIST: Type Method Description Amount Payment Check 217 ACCOUNT ITEM LIST: Description TOTAL: 1,125.44 1,125.44 Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 123.00 000/345.830 1,002.44 TOTAL: 1,125.44 TO TN oonor nc AC INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (4` 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 INSPECTION NO. Projects Li,9% //1 0 l/, 5T Type of Inspection: / ap �i �J Address: 1 1/26 C C PM. Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Ap roved per applicable codes. Corrections required prior to approval. ¶OMMENTS: 00(`Of'IL o . Ins e Date p : 7/x.3,% ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: fio?-26(i) INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ^/ CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 &70 3 project LA VigAig. Type of In ion _ , ql�f-C1 WZOi/1 b War L-- i /Y/17 tIc-)')(- Address, "Ve2-6 Sc PV-)k., bate Called: m Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: h. WZOi/1 b War L-- i /Y/17 tIc-)')(- pi,-77964 it N11 1 St C 045 m fI U 7LLE /A) 57 ,10-7.-- pus 77LL i O, 11 7-0 r ac /< Insp 11-1, 77,trAdal °"5 /x /vFl El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPE ION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Protect: { Type of Inspection: 7003 Address: 2' � Date Called: Special Instructions: Date Wanted: 11 " 1 i a.m. p.m. Requester: [[[[ Phone No: X Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0 - Cfic,inlll 6.0✓cc KOvC t4 r/ Inspector: _Tel &WK._ Date: 01 L. o'' EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: r°- . ;- , ..A= utaallwav= - ps. - -- INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431436V0 Project: 44 1 iit.4 661 Type of Inspection: Address: 2126, �M � I �'t�/ Date Called: Special Instructions: Date Wanted: 61 30 :m: Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Pn Inspector: Date: 04130 /AP El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ��.. ,_. • .ISM- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: J. i t2/ Type of Inspection: loa, ,/—N Address:PU74 PIAK.0 Date Called: Co4G (A) .S Special Instructions: Date Wanted: 6/i� a:m: Requester: Jr - 1SJ s, of c o4N r Phone No: riA CSC.. iLoco \ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ,/—N K. . Co4G (A) .S iID P i$ Jr - 1SJ s, of c o4N r riA CSC.. iLoco \ Inspector: -44/eic Date: ob /iq o)r ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 1Date: -�='-- L'•..maek ..�1 �` '..;.Y�r�eSa sn;:ei:. ■'-fu ISffipi ,._ .,wd�+u..m.a1 'r •= -- fAtko.m ,,.eo5.na 1 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 LOS - 2120 Project: lir. i iLt i;Oie Type of Inspection: ��v- Address: 2, t 2Z Date Called: - Special Instructions: Date Wanted: if a.m. p.m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: VA Inspector: :6frld Date: $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPEJION NO. INSPECTION RECORD Retain a copy with permit 6,454- 240 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12- 6300 South enter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: , %� Type of Inspection: ? p 07— Address:2 4/ 2r � /- Date Called: Special Instructions: Date Wanted: r ` 5 C.n. Requester: Phone No: 0:1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: c-Alc-cArzE Inspector: /TT C; Date: OS I o El $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: \c) INSPECTION NO. INSPECTION RECORD Retain a copy with permit 61.0%1 2ko PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4 ,_ } �] Type of Inspection: 7002.— Address: /I VO a 141w Date Called: Special Instructions: Date Wanted: i a i. Requester: Phone No: ❑ Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspector: Date: 0s.-%I tit �,, $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: h 2006 Washington State Nonresidential Energy Code Com•Iiance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 2426 Southcenter Mall Date 3/16/2008 Tukwila, WA 98188 For Building Department Use Applicant Name: Keith smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 REVIEWED FOR CODE COMPLIANCE E NFPA 70 - APR 1 U 2008 City Of Tukwila B ILDING DIVISION RECEIVED CITY OF TUKWIIA MAR 17 2008 PERMIT CENTER FILECOPY a(71-2je0 2006 Washington State Nonresidential Energ Code Compliance Form Interior Lighting Summary LTG -I NT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 2426 Southcenter Mall Date 3/16/2008 Tukwila, WA 98188 For Building Department Use 101 Applicant Name: Keith Smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 Project Description 103 . New Building III Addition •'4 Alteration 7. Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 0.80 130.0 • No changes are being made to the lighting 104 • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor/room no.) ( ) Occupancy Description P Y Allowed Watts per f� " Area in ft2 Allowed x Area 101 retail 1.50 2587.0 3880.5 103 stock room 0.50 1014.0 507.0 104 toilet 0.80 130.0 104.0 From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt 4491.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 Ll - CANOPY MTD. LINEAR FLUORESCENT 17 96.0 1632.0 101 12 - RECESSED FLUORESCENT 10 26.0 260.0 103 Ll - CANOPY MTD. LINEAR FLUORESCENT 7 96.0 672.0 104 L1 - CANOPY MTD. LINEAR FLUORESCENT 2 96.0 192.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt sl 2756.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Ener• Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Lighting e • Check if 95% /o or more of fixtures comply with 1,2 or 3 and rest are ballasted. Note: If occupancy type is 'Other' and Fixtures: 1.2 fl ure answer is checked, the number of (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector fixtures in the space is not limited by Code. 1521) or louvers, c) 5-60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. 1.3 tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 1.1 Dormitory 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic belles. Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' -2 (MO Use' LPA2 (WIsf) Automotive facility .LPA 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food estabiishments5, restaurants/bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia °. assembly spaces° 1.0 Theater. motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group I -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall'` 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies'' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms. elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three -quarter- height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 wfft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 12426 Southcenter Mall Date 3/16/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances fo interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG-SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2 Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 101 SALES 1.50 12.0 feet 12 feet 1.50 103 STOCK ROOM 0.50 12.0 feet 12 feet 0.50 From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 2426 Southcenter )fall Date 3/16/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Require( Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E -1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations 0.a . vertical glazing Indicate vertical glazing on plans 0.a . overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features. indicate location yes (a) timer w /backup Indicate location E -1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E -1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 (Max. watts 'Indicate watts for each exit sign 1 131 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps. ballasts, watts per fixture no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps. ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency IM_2 TRANSFORMERS (Section 1540) yes I 1540 (Transformers . 'Indicate size and efficiency IE_2 I If "no" is circled for any question, provide explanation: %MT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -260 DATE: 07 -11 -08 PROJECT NAME: LEARNING QUEST TOYS SITE ADDRESS: 2426 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 3 After Permit Issued DEPART i ENTS: >„l ing Ir Ivislon Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07 -15 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: UNo further Review Required DATE: APPROVALS O Approved Notation: REVIEWER'S INITIALS: CORRECTIONS: Approved with Conditions DUE DATE: 08 -12 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPI. PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -260 DATE: 06 -16 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 2426 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # after Permit Issued DEPARTMENTS: BUilaing Division2 Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-1 7 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route FX Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved VI Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -15 -08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 *PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -260 DATE: 05 -15 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 2426 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 After Permit Issued DEPARTMENTS: fif BuiT Ing Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete P Comments: Incomplete DUE DATE: 05 -20 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: DUE DATE: 06-17-08 Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip doc 2 -28-02 OPERMIT COORD COPY 0 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -260 DATE: 03 -17 -08 PROJECT NAME: WESTFIELD VACANT SPACE SITE ADDRESS: 2426 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: itaR) Lf'� Bui ding Division Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 17f Incomplete Comments: DUE DATE: 03-20-08 Not Applicable f Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required nNo further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04-17-08 Approved n Approved with Conditions 71 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: LIF \f 0192* SITE ADDRESS: 2L42(y C't AAA PERMIT NO: �.(, 0 ORIGINAL ISSUE DATE: pr10� REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INIT S 3 -7 -u-0g 1,-)- -3-0� (p -�-�I -Or Summary of Revision: C v w 4 0 TZ - Zre 3 I; till Summary of Revision: C ALT p� r p( (t uut,,,r.w- 1 U'rr s 1 oc /G-Prt PC- �ftm 'IPA ON { t ( Received by: LAo('L fa (Afar_, REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 3 -7 -u-0g 1,-)- -3-0� Summary of Revision: C v w 4 0 TZ - Zre 3 I; till Summary of Revision: [A W - pLiw ter is -p ewe Tv ,r-, \ n & b Wll. ' y,..- Received by: Ltniti .14 ate. Received by:/o. ease print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 3 -7 -u-0g 1,-)- -3-0� Summary of Revision: C v w 4 0 TZ - Zre 3 I; till Summary of Revision: Received by: Ltniti .14 ate. (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431-3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 71//14' Plan Check/Permit Number: LL U�r - Z C Q ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # '- after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner �& es"- a ys 4y, er/ W e,57L Y4)1,14 &x) Project Name: Learn; Project Address: Z St 26 Sa ee 4 ce-.-,4 /474. 4 Contact Person: M4 re-4` « Peez7d Phone Number: c5)/ 8 - L - 2.� Summary of Revision: 4-7 ; //rt &X A' 71- /•jG m-Q— ry c'. t O7 /, �, �"'e��..� sQ fz� rP�-lr� Gc -� e e S PMi Pe rrz� S'cn-o scsesr Sz ycr /7 t, x strc�3 ID rte P 4/- e Vk. /ryl& k he �Ir7Z.4. h7 ji4jt, /14 &x 6e • 77;416_ (age- : O , /JJre9 -rs oCC : /' Va Sheet Number(s): -- / // 3 /i (5:7l-F.5 / Y S � i z, Y) rtrrr n *rte "Cloud" or highlight all areas of revision including date of rev, Received at the City of Tukwila Permit Center by: 1S----Entered in Permits Plus on iapplications \forms - applications on linelrevision submittal Created: 8 -13 -2004 JUL 1 1 2008 Nk•tua•• • d,■ie 6,h • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, far, etc. Date: (. /e$ Plan Checic/Permit Number: L — 2 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # E Revision # Z after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: I e61-4 e &d V% //4 Re X Project Address: /ll4 l Contact Person: / 7 — c t /ett<ez// Go,•J Phone Number: 2t - R 2 - a7 Summary of Revision: /1 ez) 6-1 c.:./6) crci L /11,417. l� /L r� u i 5 re>4- cie % ice, 0 14 TZ'/ RECEIVED TI U(WPl A JUN 16 2008 PERMIT CENTER Sheet Number(s): — / , – "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by 4 Entered in Permits Plus on .app1cations\fonms- applications on Iinelrevision submittal Created: 8-13 -2004 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite # 100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fay etc. Date: s/948' Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correctio Letter # [ Revision # % Permit is Issued LZ -266 ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: CPV gnitq A MAY 15 2008 PERMIT CENTER IV#5H e(( k ,, ii-e X Project Address: 24'Zet, Scut lAGe,, Aar- M4 /1, 774 kli_.) 6 t Lod-- ?8/ Contact Person: /974, -4'k. Rte, "tvr -at- Phone Number: . - c'DZ - (D 7/ Summary of Revision: e IS lee • 4, cs.t. Gt.) r- L e A, /25, /e. e re,./-2-L5- 'ea k- oil He ij--S & e.S 6 Sic leS •20 -e2 (Ae. D ! © E/ ee l-7- cAX /few.," p/.4.„ 61-7-, 6 /ee? ,Z)e 4 4 7)4 ,' ( 4' o'i s h ee p - / Sheet Number(s): g / F -Z 3 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on t tai b lepplications\fmms- applications on Iinerevision submittal Created: 8 -13 -2004 orw iaori• Look Up a Contractor, Electri or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SMEINS *066DB Licensee Name S M E INC OF SEATTLE Licensee Type ELECTRICAL CONTRACTOR UBI 601524252 Ind. Ins. Account Id Business Type CORPORATION Address 1 828 POPLAR PL S Address 2 City SEATTLE County KING State WA Zip 98144 Phone 2063292040 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/2/1994 Expiration Date 3/2/2010 Suspend Date Separation Date Parent Company Previous License Next License PACIFFS973PU Associated License BAKERJT973LR Master Electrician Information License BAKERJT973LR Name BAKER, JON T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MARVICH, STEPHEN E 01/01/1980 PINSKY, ADAM A 01/01/1980 BAKER, JON T AGENT 01/01/1980 • I Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SMEINS *066DB 05/07/2008 ® PROVIDE MD INSTALL NEW 30 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW VAV. VERIFY LOCATION IN FIELD. PROVIDE AND INSTALL NEW DISCDINECT AND ALL ASSOCIATED ELECTRICAL FROM PANE. TO NEW WATER HEATER ABOVE CEILING VERIFY LOCATION IN FIELD "--\ PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO U STOREFRONT SIGN PER N.EC 2426 Southcenter Mall Tukwila, WA 98188 IIlF --:4IU 7,9,11 REV IONS No chances shall . - made to the scope 318 terry avenue n of work without prior approval of seattle, Washington 98109 Tukwila Buil. ing Division. NOTE: Revisi • ns will r- iuire a new plan submittal 206.838.5485 p and may in ' Iude add ional plan review fees. 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant FLOOR PLAN NOTES BY SYMBOL TRENCH TO CASHWRAP 0 VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. O INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 LINE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THWN. NOT USED FILE COPY Permit No. fillitjAQ Mar review approval Is Subject to mots and omissions. Approval of construction documenb3 does not authorize the violation of any adopted code or orb. Receipt of approved field Copy and conditions is edged: LECTRICAL /POWER PLAN Consultant Registration Architect Registration LIGHT FIXTURE SCHEDULE PLAN MANUFACTURER MODEL # DESCRIPTION MARK A COOPER /METALUX 2GA332A120VEB82 2'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING B UTHONIA 8K7AZ INCANDESCENT RECESSED DOWNUGHT, 8' 60 WATTS C COOPER/METALUX GA232M2OVEB81 7'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL -LIGHT LXURWELED LITEFORM COLLECTION EXIT UGHTS/BA I ILRY BACKUP X2 SUREUTES CC7 EMERGENCY LIGHTING /BULBS INCLUDED i HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -277V -WHITE Dsl PASSIVE INFRARED AND UTILIZE AS ADAPTIVE HUBBELL ATP1277W MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY Ds'e ULTRASONIC AND UTILIZE AS ADAPTIVE HUBBELL ATU1277RRW MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY Issues and Revisions No. Date Issues By Check ■■■ ■■ • ■■ ■ ■■ LEEEEE T• ENT■ ■■■■■■ i ■::ii::: i `11MM11 1 =MI l� PAMEEMO i R. ..■ • ..■.. ■■ .. .. ■■ ■■■■ ■.■■ :: ■■: OEM .. .:e =EWE IONE= •• ME • ■■I■■.■ MM. _ • M■■.. ■.■■■ MIME ■ ■ ■■ • ser.......mi _ 1 1 MIIIIIIIIIIISIIIM --- 111111911110411111,1\ II- ..... i , E IIIIICAM" ii prp.m.0._,_ town Isms !idirmmommalki, i. wommirish- # 11111111111=1111 gpm . . , l'Eul• .111111MITAS ig gmk --AN._ AM 7 lin 11 Ira ION IIIL. _ A__ c, IMMINITIEMEN i 1111011111 1111111111 ) k 1 _ \ n 1 MINMERIMINETill - M.M.11 11.11.E. 11111111 11111.11111111.11111111111111 . 1 02.08.08 2 03.26.08 3 04.07.08 4 04.21.08 5 05.30.08 6 06.01.08 PERMIT BLDG. COMMENTS PERMIT CORR. OWNER REVISIONS ISSUE EGRESS KLS KLS KLS KLS KLS KLS MC PERMIT CENT& Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description POWER /LIGHTING PLAN Public Works, wilding Di PERMIT NUMBER 08 2 0 �o TAG Computer File CW05- 2008-- E1,DWG rle AS NOTED Template 4,3 (12 0 101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. ELECTRICAL /LIGHTING PLAN FLOOR PLAN NOTES BY SYMBOL O VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 UNE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THWN. O NOT USED LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL $ DESCRIPTION A COOPER/METALUX 2GA332A120VEB82 2'x4' LAY -IN FLUORESCENT, TB ENERGY SAVING B UTHONIA 8W1AZ INCANDESCENT RECESSED DOWNUGHT, 8" 60 WATTS C CODPER /METALUX GA232Al2DVEB81 1'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL -LIGHT LXURWE]ED UTEFORM COLLECTION EXIT LIGHTS /BATTERY BACKUP X2 SUREUTES CC7 EMERGENCY UGHTING /BULBS INCLUDED HUBBELL CS1221W SINGE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -277V -WHITE DgE HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY r HUBBELL ATU1277RRW ULTRASONIC AND UTIUZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY 3a 11 '13 0I H 1,3,5 1 ELECTRICAL /POWER PLAN l ;LE_ 1,4 _ O■ 7,9,11 ® PROVIDE AND INSTALL NEW 30 Ale' NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW VAV. VERIFY LOCATION IN FIELD. PROVIDE AND INSTALL NEW DISCONNECT AND AU. ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER AHOVE CEILING. VERIFY LOCATION IN FIELD. PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER NEC. 34 30 TRENCH TO CASHWRAP 1( n B B 26 24 36 111 ill <l11 + 14' -0" AFF 11VHE _II ® min mom mom EMI= summa Naffs mem mum imirdre maw. 1 OMB 2426 Southcenter Mall Tukwila, WA 98188 smith co. 318 terry avenue n Seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithoo.org/ FIcViSi(ilj$ — C"orfs �Itant No changes snail be made to thn score of work wi`ho jt prior approval of Tukwila Building Division. NOTE: Revisions will require a new nlen sithrni4 +ai and m y include additional plan revi7w fe 1 Pe nit N CY) REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUN 2 3 2008 / f lYJ City Of Tukwila BUILDING DIVISION 6294 REGISTERED ARCHITECT KEI STATE OF WASHINGTON nsultant Registration Plar review approval is subject to errors and omissions. Approvzf of construction documents does not ttcr: o the violation of any adopted code or ordinance. R.t't of approved Field Copy and conditions is ao cige: Ey Date: 15 City of Tut 'la BUILDING DIVISION i C) ) SEPARATE FERMll T REQUIRED FOR: 1 IMechani al ❑ Electrica Iumbin 1 fCl Gas Pipi City of Tul:w � L.1�m It.�ING l <i' Isio N a + 13 -6" AFF IIIIIIIIIEM MIME MN= mIlliin E-11/1111001, M Iliffirdiliiiir..11111■Mil) MillifAMEMBEft • man MEM • Ell liffli no irs- " "millimmia wall IIIII"Nmmmi lin I waglizimmaiiii 11111.mmil I AFF, ELECTRICAL /LIGHTING PLAN UNIFY Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 2 03.26.08 3 04.07.08 4 04.21.08 5 05.30.08 PERMIT BLDG. COMMENTS PERMIT CORR. OWNER REVISIONS ISSUE KLS KLS KLS KLS KLS Public Works, Building Division PERM f NUMBER CITY OF Tt I K \:' I A uuti Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description POWER /LIGHTING PLAN Computer File CW05--- 2008- E1,DWG Scale AS NOTED Template (1 :' I )1, I 1 ) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. E-1 FELE COPY NEW PA \I-- L 8 Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X -- — — SPACE 2 N/A 3 3 TRACK LIGHTING 1200 12 1/20 X -- — — SPACE 4 17,165 3 5 TRACK LIGHTING 1200 12 1/20 — X -- — -- SPACE 6 — 3 7 SPACE — -- — X -- — — SPACE 8 — 3 9 SPACE — -- — X -- -- — SPACE 10 — SPACE 11 SPACE -- -- -- 600 X — -- — SPACE 12 — SPACE 13 SPACE -- — — X — -- — SPACE 14 — 2 15 SIGN 1200 12 1/20 X -- -- — SPACE 16 — SPACE 17 SPACE — — -- X — -- — SPACE 18 19 SPACE — — -- X — — — SPACE 20 21 SPACE — -- -- X -- — — SPACE 22 23 SPACE — — -- X — — — SPACE 24 25 SPACE — — — X — — -- SPACE 26 27 SPACE — -- -- X -- -- — SPACE 28 29 SPACE — — -- X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE — — -- X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE — — -- X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE — — -- X 1/20 12 1000 GENERAL RECEPTACLES 36 37 SPACE — — -- X 1/20 12 1000 GENERAL RECEPTACLES 38 39 SPACE — — -- X 1/20 12 1000 GENERAL RECEPTACLES 40 41 SPACE — -- — X — — — SPACE 42 REMARKS TOTAL LOAD PHASE 'A' 2710 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 4480 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 3700 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 10450 WATTS MANUFACTURERS RECOMMENDATION 31 AMPS 5 - PROVIDE HA.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL LOAD V v ARY \EW PA \ -L H Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 2.2 1 FMB -1 1000 10 3/20 X 1.00 1/0 20,030 TRANSFORMER 2 N/A 4 3 X 3/125 19,150 1000 4 4 120 5 SIGN X 17,165 1000 6 1 SUPPLEMENTAL HVAC 7 SPACE — — -- X -- — — SPACE 8 L TOTALS_ 4 9 SPACE — — -- X — — — SPACE 10 11 SPACE -- — — X — — — SPACE 12 13 GENERAL LIGHTING 600 12 1/20 X — — — SPACE 14 15 GENERAL LIGHTING 800 12 1/20 X — — — SPACE 16 17 GENERAL LIGHTING 300 12 1/20 X -- — — SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 21630 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61045 WATTS MANUFACTURERS RECOMMENDATION 170 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL LOAD V v ARY • 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK PPPPoci OVERRIDE SWITCHES a .e. .c. L__ —_..J LIGHT SWITCHING DETAIL PJ I T TO ' =,C ALE SIGN LIGHTS (B15) GENERAL LIGHTS (B3) • GENERAL LIGHTS (B15) • GENERAL LIGHTS (017) P A \- L RISER D A G R A PH 1 I i T- LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE I VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. 1 . LIGHTING 2.2 1.25 2.8 208 1 RECEPTACLES 7.2 1.00 7.2 120 1 WATER HEATER N/A 1.00 N/A 208 1 TRACK LIGHTING 2.4 1.25 3.0 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC .1 1.25 .125 120 1 HVAC 11.0 + .25 OF LARGEST LOAD 13.8 480 3 L TOTALS_ 24.1 28.4 KW = 23 6 AMPS 0 120/208 SERVICE • 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK PPPPoci OVERRIDE SWITCHES a .e. .c. L__ —_..J LIGHT SWITCHING DETAIL PJ I T TO ' =,C ALE SIGN LIGHTS (B15) GENERAL LIGHTS (B3) • GENERAL LIGHTS (B15) • GENERAL LIGHTS (017) P A \- L RISER D A G R A V RISER DIAGRAM GENERAL NOTES 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 277/480V 3 PH, 4 WIRE ELECTRICAL SERVICE I VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. 1 . v RISER DIAGRAvA NOTES BY SYN BOL ® PROVIDE AND INSTALL (4) #1 /O THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. ® PROVIDE AND INSTALL METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS. O PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUIT. ® PROVIDE AND INSTALL (4) #1/o THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL H. ® PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR FMB -1 ® NOT USED $ PROVIDE AND INSTALL 30 AMP DISCONNECT FOR FMB -1 IN CEILING. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL (1) #4 CU, GROUNDING ELECTRODE CONDUCTOR TO BLDG. STEEL 10 NOT USED 11 PROVIDE AND INSTALL (3) #1 /O THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER W /#6 CU GROUND PER NEC 250 -122 12 PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. 13 PROVIDE AND INSTALL (4) #3/0 THWN CU, (1) 0 GROUND IN 2" CONDUIT FOR PANEL 'B'. 14 PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS REQUIRED 0 NEW PANEL �- I f EXISTING ELECTRICAL I ( I I NEW NEW : j 14 COFOR DISTRIBUTION SYSTEM(S) OTHER TENANTS (I) L _. __ — _ __ -. 1 EXISTING LANDLORD WIREWAY I TENANT 0 CD 0 FLOOR LANDLORD (� �=–� PROVIDE AND INSTALL GROUND BUILDING STEEL PER R N.E.C. 250 -66 2426 Southcenter Mall Tukwila, WA 98188 smith co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith ©smithco.org http: / /www.smithco.org/ Consultant 6294 Consultant Registration REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC JUN 2 3 2008 City Of Tukwila B ILDING DIVISION Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 PERMIT KLS 2 03.26.08 BLDG. COMMENTS KLS 3 04.07.08 PERMIT CORR. KLS 4 04.21.08 OWNER REVISIONS KLS 5 05.30.08 ISSUE KLS RECEIVED CITY OF TUKWILA JUN 16 2008 PERMIT CENTER Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG Scale AS NOTED Template .. I I ) ( H) I! All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -2 FLOOR PLAN NOTES BY SYMBOL ® VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T-1 LINE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND IMRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #13 AWG TH • NOT USED ® FM;i.A4P-INSTALE N ® PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL # DESCRIPTION A COOPER/METALUX 2GA332A120VEBB2 2'x4' LAY-IN FLUORESCENT, T8 ENERGY SAVING B LJTHONIA SWIAZ INCANDESCENT RECESSED DOWNLIGHT, 13. 60 WATTS C COOPER/METALUX GA232A120VEB81 1'x4' LAY-IN FLUORESCENT, TB ENERGY SAVING XI DUAL-LIGHT LXURWELED LITEFORM COLLECTION EXIT LIGHTS/BATTERY BACKUP X2 SURELITES CC7 EMERGENCY LIGHTING/BULBS INCLUDED $ HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SIMTCH. 20A 120-277V-WHITE esi. HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY DSE HUBBEU, HUBBW. ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST IIME DELAY AND SENSITIVITY / • ,,, B 11713 0 1,3,5 ELECTRICAL/POWER PLAN SALE: 1/4" = 7,9,11 OFRONDE AND INSTALL NEW DISCONNECT AND AL ASSOCIATE) ELECTRICAL FROM PANEL TO NEW WATER ram ABOVE CEILING. VERIFY LOCATION Di FIELD. FRONDE AND LNSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. 30 7 ( TRENCH TO CASHWRAP I I B B 26 24 36 A:r-r ',ArT GJQI 1D soze# H MENEM MEM MENEM MENEM: ••PAMW.;. 115.71r0MV; XI 0, 0 0 0 0 0 1/ 0 0 0 0 sormem- ••1111MW:-- 1110P-M,..VS, X2 11 •••••• •••••• _ 0 4 ),, z", ..0" /1 1 : X2 •1111111•• •ENEM •••••• 1111110•• ••••• •••••• ••IMI• •MIEM•• ..-... •••11•11 • j_ • 1 1 •111110MI• M •••••• •••••• •••••• =EMU INEMMEM EMU •IRE MENA ••IIM• IMMUNE • FILE Permit No OPY 2426 Southcenter Mall Tukwila, WA 98188 smith co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith©smithco.org http://www.smithco.org/ Consultant 0 Plar review approval is subject to errors and omissions. Approval of condo:Mon documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Fd Copy and conditions Is admowiedged: By Date., (0 a In g City of Tukwila BUILDING DIVISION •••••• MIEUM•• 1•••••• ••111111•• •••••• MENEM H 13 ELECTRICAL/LIGHTING PLAN SCALE: 1/4" = 1'-0" 6294 Consultant Registration REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 2 03.26.08 3 04.07.08 4 04.21.08 PERMIT BLDG. COMMENTS PERMIT CORR. OWNER REVISIONS KLS KLS KLS KLS RECELVERvim CITY OF TU MAY 1 5 Z008 Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description POWER/LIGHTING PLAN Computer File CW05-2008-E1DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E-1 NEW PA \EL. B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X -- -- -- SPACE 2 2 3 3 SPACE - -- - X -- -- -- SPACE 4 X 3 5 SPACE - -- -- VAV 2 X -- -- - SPACE 6 - 3 7 SPACE - -- - X -- -- -- SPACE 8 4 3 9 SPACE - -- - X -- -- - SPACE 10 13 GENERAL LIGHTING 11 WATER HEATER 750 12 2/20 - X -- -- -- SPACE 12 15 X -- -- - SPACE 14 - - 13 750 2 15 SIGN 1200 12 1/20 X - - - SPACE 16 18 17 SPACE - - -- X - - - SPACE 18 19 SPACE -- -,- -- X -- -- - SPACE 20 21 SPACE -- -- X - SPACE 22 23 SPACE .... -- -- X 1/20 12 1500 GENERAL RECEPTACLES 24 25 SPACE - - -- X 1/20 12 1500 GENERAL RECEPTACLES 26 27 SPACE - - -- X 1/20 12 360 GFI RECEPTACLES 28 29 SPACE - - -- X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE - -- - X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE - -- - X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE - -- - X 1/20 12 1000 GENERAL RECEPTACLES 36 37 RTU -1 3133 6 3/50 X 1/20 12 1000 GENERAL RECEPTACLES 38 39 3133 X 1/20 12 1000 GENERAL RECEPTACLES 40 X -- - SPACE 42 41 3133 REMARKS TOTAL LOAD PHASE 'A' 11,108 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 11,703 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 11,363 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 34,174 WATTS MANUFACTURERS RECOMMENDATION 95 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. \FW PANES I A G R A V Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 1.25 1 VAV 1 2500 10 3/20 X 12.9 1/0 20,030 TRANSFORMER 2 1.00 X 3/125 4 3 19,150 4 4 2500 1 5 1.2 X 17,165 6 1 2500 1.4 7 VAV 2 2500 10 3120 X - - - SPACE 8 34.1 2500 X - - -- SPACE 10 4 9 11 2500 X - - - SPACE 12 13 GENERAL LIGHTING 1250 12 1/20 X -- - - SPACE 14 15 GENERAL LIGHTING 980 12 1/20 X - - - SPACE 16 17 GENERAL LIGHTING 1345 12 1/20 X - - - SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 25,030 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 24,150 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 22,165 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 71,345 WATTS MANUFACTURERS RECOMMENDATION 86 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL LOA' SJ N VARY 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK • • OVERRIDE SWITCHES b7 • SIGN LIGHTS (B15) • GENERAL LIGHTS (83) • 'd' • OFFICE LIGHTS (B5) L____J LIGHT SWITCHING DETAIL NOT TO SCALE OFFICE LIGHTS (B7) RECEPTION LIGHTS (B9) P A\ E L RISER D I A G R A V LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. 1 r LIGHTING 4.8 1.25 6.0 120 1 RECEPTACLES 15.8 1,00 12.9 120 1 WATER HEATER 1.5 1.00 1.5 208 1 MISCELLANEOUS N/A 1.00 N/A 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC 1.4 1.25 1.7 120 1 HVAC 9.4 + .25 OF LARGEST LOAD 11.9 208 3 TOTALS: 34.1 35.5 KW = 98.6 AMPS @ 120/208 SERVICE 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK • • OVERRIDE SWITCHES b7 • SIGN LIGHTS (B15) • GENERAL LIGHTS (83) • 'd' • OFFICE LIGHTS (B5) L____J LIGHT SWITCHING DETAIL NOT TO SCALE OFFICE LIGHTS (B7) RECEPTION LIGHTS (B9) P A\ E L RISER D I A G R A V RISER DIAGRAM GENERAL NOTES 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN HELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 3 PH, 4 WIRE ELECTRICAL 4 WIRE ELECTRICAL SERVICE VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. 1 r -® (q� RISER DIAGRAv NOTES BY SYMBOL O PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. O PROVIDE AND INSTALL METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS, O PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUIT. ® PROVIDE AND INSTALL (4) #1 /O THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'H'. g PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU-1 ON ROOF. ® PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU -2 ON ROOF. ® 8 PROVIDE AND INSTALL 30 AMP DISCONNECT FOR RTU -1 ON ROOF. VERIFY LOCATION IN FIELD. K) PROVIDE AND INSTALL 30 AMP DISCONNECT FOR RTU -2 ON ROOF. VERIFY LOCATION IN FIELD. 10 NOT USED 11 PROVIDE AND INSTALL (3) #1/0 THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER. 12 PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. 13 PROVIDE AND INSTALL (3) #3/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'A'. 14 PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS REQUIRED V T 1 ► r EXISTING ELECTRICAL I I I 1 NEW PANEL 'H' NEW PANEL -- 14 C DISTRIBUTION SYSTEMS) FOR OTHER TENANTS L 1 EXISTING LANDLORD WIREWAY 1 I 1 I 0 ® 12 FLOOR LANDLORD TENANT PROVIDE AND INSTALL GROUND TO BUILDING STEEL PER N.E.C. 2426 Southcenter Mall Tukwila, WA 98188 smith co• 318 terry avenue n seattle, washington 98109 206.838.5485 p 206113.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant 6294 Consultant Registration Architect Registration Issues and Revisions No. Date Issues By Check 1 02.08.08 PERMIT KLS 2 03.26.08 BLDG. COVMENTS KLS 3 04.07.08 PERMIT CORR. KLS 4 04.21.08 OWNER REVISIONS KLS QE410,1 P HOC (2, o 10% �UZ�� CITY OF TUaC11111LP► � ,��Gp . Z. MAY 15 2008 i CE1'� a< s»R Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use an and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -2 PART 1 - GENERAL 1.01 SCOPE OF WORK: FURNISH AND INSTALL ALL EQUIPMENT AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENT AND SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND /OR SPECIFIED HEREIN. ALSO ARE INCLUDED ALL OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION INCLUDING ALL ACCESSORIES AND APPURTENANCE REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWING AND SPECIFICATIONS THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. 1.02 REGULATORY REQUIREMENTS CODE COMPLIANCE IS MANDATORY. NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMITS WORK AND NOT CONFORMING TO THESE CODES. WHERE WORK IS SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (OSH). 2. NFPA #70; NATIONAL ELECTRIC CODE (NEC). 3. NFPA #101: LIFE SAFELY CODE. 4, STATE FIRE MARSHAL. 5. LOCAL UTILITIES COMPANIES. 6. ALL LANDLORD GENERAL REQUIREMENTS FOR MAW 1.03 LICENSE. FEES AND PERMITS: ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMITS AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. 1.04 SAFETY AND INDEMNITY: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. NO ACT, SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER, THE ENGINEERS OR THEIR CONSULTANTS, 15 INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, OR NEAR THE CONSTRUCTION SITE. 1.05 DRAWINGS AND SPECIFICATIONS: ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF THIS DIVISION SHOW ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENTS SHALL BE GOVERNED BY CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS, WHETHER SPECIFICALLY MENTIONED OR NOT. 1.06 CONDITIONS AT SITE: THE ELECTRICAL CONTRACTOR SHALL HAVE EXAMINED THE SITE AND FAMILIARIZED THEMSELVES WITH ALL DISCERNIBLE EXISTING CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS SHALL BE INCLUDED IN THE BID. 1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF WORK. THE CONTRACTOR SHALL BE A LICENSED MASTERED ELECTRICIAN OF THE STATE IN WHICH THE JOB IS LOCATED. 1.08 SHOP DRAWINGS AND MATERIALS LISTS: SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS LISTS, AS NOTED BELOW, FOR REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. SUBMITTALS REQUIRED AS FOLLOWS: 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. 2. ENCLOSURES FOR UTILITY COMPANY METERING. 3. MAIN FUSED DISCONNECT SWITCH. 4. PANELBOARDS 5. DISCONNECT SWITCHES 6. LIGHT FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. 1.09 SUBSTITUTIONS: ONE OF MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION IS PERMITTED. NO WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE OWNER. THE OWNER IS THE SOLE JUDGE OF ACCEPTABILITY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM IS PERMITTED, AND ANY RE- DESIGN EFFORT 15 THEREBY NECESSITATED, THE REQUIRED RE-DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.10 COORDINATION: COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH -IN AND CONNECTION FOR EQUIPMENT FURNISHED UNDER OTHER TRADES THAT REQUIRED ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES THAT REQUIRE ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABILITY AND CODE COMPLIANCE. VERIFY EQUIPMENT DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. 1.11 CUTTING AND PATCHING: ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION 15 INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND OTHER TRADES 15 IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER HOLES, SUPPORTS, ETC. 1.12 ACCEPTANCE DEMONSTRATION: UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR OWNER THE OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. PROPERTY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND /OR TEST TIME SWITCHES PROGRAMMING. 1.13 RECORD DRAWINGS, EQUIPMENT DATA: MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH AS -BUILT INFORMATION AS FEEDER AND SERVICE ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION. DELIVER COMPLETED DRAWINGS TO THE OWNER. DELIVER TO THE OWNER'S REPRESENTATIVE THREE COPIES OF DATA SHEETS OR OTHER CURRENT MANUFACTURERS PUBLICATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT INCLUDING AT LEAST THESE DATA: 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS UST. 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. 3, USER'S MANUAL AND OPERATING INSTRUCTIONS. 4. MANUFACTURER'S WARRANTY. 1.14 CLEANUP RID THE PREMISES OF SCRAP MATERIALS, TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. 1.15 GUARANTEE: GUARANTEE THE INSTALLATION FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHANGE. 1.16 TEMPORARY SERVICES: PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE PREMISES FOR BENEFICIAL OCCUPANCY. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: 1. THREE 20 -AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE CFI TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA REQUIREMENTS. 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARALLEL TO THE DEMISING WALLS, WITH ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN ROWS TO SIXTEEN FEET OR LESS. 3. FLOOD LIGHTING AND TASK LIGHTING FOR PAINTING AND OTHER FINISH WORK. WHEN PERMANENT ELECTRICAL SERVICE IS OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT USED FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR REMOVAL OF TEMPORARY SERVICE PROVISIONS. 1.17 OWNER - FURNISHED ITEMS: CONTRACTOR SHALL INSTALL, CONNECT AND COMPLETE THE FOLLOWING ITEMS FURNISHED BY THE OWNER AND SHALL PROVIDE WIRES, CABLES, CONNECTORS, PIGTAILS, CORDS AND CORD -CAPS, BOXES, CONDUIT, PLATES, SUPPORTS, AND. OPERATING TESTS TO MAKE COMPONENTS AND SYSTEMS OPERATE SATISFACTORILY. PROVIDE SYSTEMS DRAWING FROM THE MANUFACTURER THROUGH THE OWNER IN ORDER TO INSTALL COMPLETE OPERABLE SYSTEM. 1. MUSIC SOUND SYSTEM COMPONENTS. 2. ENTRY ALARM SYSTEM CONTROL PANEL AND CONTACTS /SECURITY SYSTEMS. PART 2 - PRODUCTS 2.01 MATERIAL APPROVAL ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITER'S LABORATORIES LABEL. MATERIALS THAT ARE NOT COVERED BY UL TESTING STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AFTER INSTALLATION. 2.02 CONDUITS AND OTHER RACEWAYS: A. RIGID STEEL: HOT-- DIPPED GALVANIZED. B. INTERMEDIATE METAL CONDUIT (IMC): HOT- DIPPED GALVANIZED C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO- GALVANIZED. D. WIREWAY CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND OUTDOORS. 2.03 WIRES AND CABLES: A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: 1. CONDUCTOR: MINIMUM SIZE #12 . A. #12 AND #10 AWG SOLID COPPER. B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. 2. INSULATION TYPE: A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THWN FOR DRY LOCATIONS. B. #10 THROUGH #4/0 AWG: XHHW (55 MILS). C. #250 MCM AND LARGER XHHW (65 MILS). D. GROUNDING WIRE: TW. B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #16 AWG MINIMUM, WITH THWN INSULATION FOR UNDERGROUND OR WET LOCATIONS AND THHN INSULATION FOR DRY LOCATIONS. C. ACCEPTABLE PRODUCTS GENERAL ELECTRIC, ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING APPLICABLE IPCEA STANDARDS. 2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: A. OUTLET BOXES: 4" SQUARE X 1 - 1/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO -TYPE WITH PLASTER RING AND COVER FOR GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). B. JUNCTION BOXES SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE- GAUGE STEEL IN LARGER SIZES WITH SURFACE OR FLUSH -TYPE SCREW - MOUNTED TRIM COVERS, BOTH BOXES AND COVERS INHIBITOR- PRIMED AND PAINTED INSIDE OUT. C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN 4- 11/16" SQUARE X 2 -1/8" DEEP WITH SINGLE -GANG RING AND SIERRA #S -754N SPLIT (PLATE BUSHING. E. ALL BOXES AND ASSOCIATED COMPONENTS SHALL BE STEEL CITY 683 SERIES, WITH P60 -38 COVERPLATE. 2.05 WRING DEVICES AND PLATES: WIRING DEVICES AND PLATES SHALL BE HUBBELL. ARROW HART, GE OR P &S WITH HUBBELL NUMBERS USED TO SPECIFY TYPE USED. STANDARD DESIGN: A. SWITCH AND RECEPTACLES DEVICES SHALL BE IVORY EXCEPT WHEN THE DEVICE IS LOCATED ORE A PURPLE WALL, WHEN ON PURPLE WAIL DEVICE SHALL BE BLACK B. ISOLATED GROUND RECEPTACLES SHALL BE WHITE WITH ORANGE TRIANGLE AS REQUIRED PER NEC, MANUFACTURED BY LEVITON # 5362 -IGW OR APPROVED EQUAL. C. SWITCHES SHALL BE 20 AMP, 120/277 VOLT A.C. RATED SINGLE POLE SWITCHES SHALL BE #1221 AND 3 -WAY SWITCHES SHALL BE #1223. D. RECEPTACLES SHALL BE GROUNDING TYPE #5362. 2.06 CONDUIT HANGERS: FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR POWERSTRUT. FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM DEFLECTION NOT GREATER THAN 1/8" 2.07 WIRE CONNECTORS: FOR WIRE SIZES #8 AWG AND SMALLER INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C. 6DOV, FOR BUILDING WIRING AND 1000W IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL. FOR WIRE SIZE #6 AWG AND LARGER T & B OR EQUIVALENT COMPRESSION TYPE WITH 3M #33 OR PLYMOUTH "SLIPKNOT GRAY" TAPE INSULATION. 2.08 PANELBOARD: A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL BE OF COLD - ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20 ". FINISH EXPOSED PART WITH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GRAY ENAMEL SUITABLE FOR OVER PAINTING IN FIELD IT DESIRED. 8. BUS BARS: PROVIDE GROUND BLOCK WITH FULL COMPLEMENT OF TERMINALS IN ADDITION TO INSULATED NEUTRAL BUS. FUTURE BREAKER SPACES SHALL HAVE COMPLETE PROVISION INCLUDING BUSSES AIR CONNECTING HARDWARE. C. MANUFACTURER PANELBOARD SHALL IN GENERAL ELECTRIC TYPE AQ OR TYPE AE OR EQUIVALENT PRODUCTS OF CUTTER- HAMMER, SQUARE D, OR SIEMENS -ITE. D. CIRCUIT BREAKERS SHALL BE BOLT -ON, THERMAL- MAGNETIC, MOLDED CASE TYPE: U.L. LISTED FOR SWITCHING DUTY. BREAKERS SHALL HAVE ON OVER- CENTER TRIP FREE, TOGGLE TYPE HANDLE WITH QUICK -MAKE, QUICK -BREAK ACTION. 1. 120/208 VOLT PANELS: SHALL BE GENERAL ELECTRIC TYPE "Q" LINE, BOLT -ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING CAPACITY AS SHOWN, NO SERIES RATING ALLOWED, 2. PROVIDE MULTI -POLE UNITS WITH COMMON TRIP ELEMENT. 3. CIRCUIT BREAKERS USED ON "ON -OFF° CONTROL OF FLUORESCENT LIGHTING (PANELBOARD SWITCHING) SHALL BE UNDERWRITERS - LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABILITY. E. IDENTIFICATION: PROVIDE SCREWED -ON (NO ADHESIVES) BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION AN OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE, AND PHASE IN MINIMUM 1/4" HIGH LETTERS. EACH PANEL SHALL CONTAIN A METAL - FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. F. COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. 2.09 DRY TYPE TRANSFORMER: A. GENERAL: EQUIPMENT SHALL CONFORM TO OR EXCEED REQUIREMENTS OF NEMA, ANSI STANDARD C89.2 FOR DRY TYPE TRANSFORMERS FOR GENERAL APPLICATIONS. ACCEPTABLE PRODUCTS ARE THOSE OF GENERAL ELECTRIC COMPANYS "QHT" LINE OR EQUIVALENT SQUARE D, SIEMENS -ITE, OR CUTTLER- HAMMER. ELECTRICAL RATINGS: 1. PRIMARY WINDINGS VOLTAGE 480 VOLTS, 3- PHASE, DELTA. SECONDARY WINDING VOLTAGES 208Y/120 VOLTS, 3 -PHASE GROUNDED. FREQUENCY: 60 HZ. KVA RATING: AS SHOWN ON DRAWINGS. TOPS: SIX (6) 2.5% FULL CAPACITY TAPS, 2 ABOVE AND 4 BELOW, RATED VOLTAGE. IMPEDANCE: FOR TRANSFORMERS LARGER THAN 75 KVA, 4,5% MINIMUM, 5,75 MAXIMUM 2. WINDING TEMPERATURE RISE SHALL BE 150 DEGREES CENTIGRADE IN ACCORDANCE WITH UL SPECIFICATION ARTICLE 506. 3. TRANSEORMER SHALL BE CAPABLE OF OPERATING AT 100% OF NAMEPLATE RATING CONTINUOUSLY WHILE IN AN AMBIENT TEMPERATURE NOT EXCEEDING 40 DEGREES CENTIGRADE. 4. TRANSFORMER SHALL MEET THE DAILY OVERLOAD REQUIREMENTS OF ANSI STANDARD C57.96. C. VIBRATION ISOLATION, FACTORY - INSTALLED: PROVIDE NEOPRENE RUBBER PADS TO ISOLATE CORE AND COIL ASSEMBLY FROM TRANSFORMER ENCLOSURE. D. INSTALLATION: 1. ANCHOR TRANSFORMER SECURITY WITH MINIMUM 1/2" DIAMETER BOLTS. STRENGTH OF BOLTS USED TO SECURE THE TRANSFORMER SHALL BE SUFFICIENT TO RESIST SHEAR AND UPLIFT PRODUCED BY FORCE EQUAL TO 1/2 OF THE EQUIPMENT MASS APPLIED HORIZONTALLY AT ENTER OF GRAVITY. 2, PROVIDE 1 THICK HIGH RESILIENCY PADS TO ISOLATE TRANSFORMER FROM FLOOR OR PLATFORM. KORFUND "ELASTO RIB" OR EQUIVALENT. 3. USE FLEXIBLE CONDUITS AT LEAST 24" LONG FOR ELECTRICAL CONNECTIONS. 4. PROVIDE GROUNDING OF EACH TRANSFORMER SECONDARY INCLUDING ALL CONDUITS. WIRES, AND CONNECTORS IN ACCORDANCE WITH NEC 250 -26 AND ANY LOCAL ADDITIONAL REGULATIONS. 2.10 INDIVIDUALLY MOUNTED MOTOR CONTROLLER: A. FOR POLYPHASE MOTORS: COMBINATION MOTOR CIRCUIT PROTECTOR AND MAGNETIC STARTER, WITH 3 -LEG OVERLOAD PROTECTION. PROVIDE TWO INTERLOCK CONTACTS OF THE INTERCHANGEABLE OPEN -CLOSE TYPE. PROVIDE HAND -OFF AUTOMATIC SELECTOR SWITCH, MOTOR RUNNING PILOT LIGHT AND RESET BUTTON IN COVER. CIRCUITS 300V AND OVER SHALL BE PROVIDED WITH INDIVIDUAL 120V CONTROL TRANSFORMERS. B. STARTERS FOR FRACTIONAL HORSEPOWER 120V MOTORS SHALL BE MANUAL TYPE UNLESS SHOWN OTHERWISE, EQUIPPED WITH BUILT -IN OVERLOAD PROTECTION. C. ACCEPTABLE MANUFACTURERS GENERAL ELECTRIC SIEMENS, SQUARE 0, CUTTER- HAMMER, AND ALLEN BRADLEY. 2,11 LIGHTING A. LIGHTING TO BE PROVIDED BY OWNER. SUBCONTRACTORS TO INSTALL ALL FIXTURES COMPLETE, INCLUDING LAMPS AND BALLASTS, READY FOR SERVICE. B. SUPPORTS: PROPER SUPPORTS AND MOUNTING ACCESSORIES, SUCH AS HANGERS, STEMS, YOKES, PLASTER FRAMES, ETC SHALL BE PROVIDED AS REQUIRED BY THE TYPE OF CEILING INSTALLED. WHERE SWIVEL CANOPIES OR BALL ALIGNERS ARE SPECIFIED, THEY SHALL CAUSE FIXTURE TO HANG PLUMP REGARDLESS OF CEILING SLOPE. C. FIXTURE DESIGNATION: FIXTURE TYPES ARE DESIGNATED ON DRAWINGS, WHERE ONLY ONE FIXTURE DESIGNATION 15 SHOWN, IT APPLIES TO ALL FIXTURES IN THAT ROOM OR AREA. FOR EXACT FIXTURE COUNT AND LOCATION REFER TO REFLECTED CEILING PLAN. D. WIRE 1 -LAMP AND 3 -LAMP FLUORESCENT FIXTURES IN TANDEM WHERE REQUIRED BY CODE. E. BALLASTS: ADVANCE, GE, OR APPROVED HIGH FREQUENCY ELECTRONIC, FULL LIGHT OUTPUT, ENERGY SAVING, CLASS "P ", HIGH POWER FACTOR. ETL CERTIFIED, SOUND RATING "A" OR AS INDICATED ON DRAWINGS. 2.12 MISCELLANEOUS MATERIALS: A: SAFETY SWITCHES: HEAVY DUTY TYPE, 600V, HORSEPOWER RATED FOR MOTORS, FUSED OR NON -FUSED AS REQUIRED. MOUNT IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR CUTLER - HAMMER. PART 3 - EXECUTION 3.01 GENERAL A. ELECTRIC SYSTEM LAYOUTS INDICATED ON THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. GOVERN EXACT ROUTING OF CABLE AND WIRING AND THE LOCATIONS OF OUTLETS BY THE STRUCTURE AND EQUIPMENT SERVED. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS. B. CONSULT ALL OTHER DRAWINGS, VERIFY SCALES AND REPORT ANY DIMENSIONS, DISCREPANCIES OR OTHER CONFLICTS WITH OWNER BEFORE SUBMITTING BID. C. ALL HOME RUNS TO PANELBOARDS ARE INDICATED AS STARTING FROM THE OUTLET NEAREST THE PANEL AND CONTINUING IN THE GENERAL DIRECTION OF THAT PANEL. CONTINUE SUCH CIRCUITS TO THE PANEL AS THOUGH THE ROUTES WERE COMPLETELY INDICATED. TERMINATE HOMERUNS OF SIGNAL, ALARM, AND COMMUNICATION SYSTEMS IN A SIMILAR MANNER. D. AVOID CUTTING AND BORING HOLES THROUGH STRUCTURE OR STRUCTURAL MEMBERS WHEREVER POSSIBLE. OBTAIN PRIOR APPROVAL OF OWNER AND CONFORM TO ALL STRUCTURAL REQUIREMENTS WHEN CUTTING OR BORING THE STRUCTURE IS NECESSARY AND PERMITTED. E. FURNISH AND INSTALL ALL NECESSARY HARDWARE, HANGERS, BLOCKING, BRACKETS, BRACING, RUNNERS, ETC. REQUIRED FOR EQUIPMENT SPECIFIED UNDER THIS SECTION. F. PROVIDE NECESSARY BACKING REQUIRED TO INSURE RIGID MOUNTING OF OUTLET BOXES. 3.02 WIRING METHODS: A. NO 'ROMEX' OR 'BX' WIRING IS PERMITTED - ALL ELECTRICAL WIRING MUST BE IN CONDUIT. B. CONDUIT SHALL BE RIGID STEEL, IMC OR EMT AS FOLLOWS: 1. ABOVE GROUND: USE RIGID STEEL IMC OR EMT. A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. B. LOCATIONS SUBJECT TO MECHANICAL INJURY: RIGID STEEL OR IMC ONLY. C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMC OR RIGID STEEL CONDUIT 2. UNDERGROUND: USE RIGID STEEL. C. USE FLEXIBLE CONDUITS IN THE FOLLOWING APPLICATIONS. 1. RECESSED LIGHTING FIXTURES. 2. MOTOR CONNECTIONS. 3. AT BUILDING JOINTS AND WET LOCATIONS, FLEXIBLE CONDUIT SHALL BE LIQUID TIGHT TYPE. D. LIGHT FIXTURES INSTALLED IN SHEETROCK CEILINGS MAY BE WIRED FROM FIXTURE TO FUTURE USING METAL CLAD (MC) CABLE. VERIFY THAT LIGHT FIXTURES ARE PROVIDED WITH JUNCTION BOXES APPROVED FOR THIS PURPOSE. MC TYPE CABLE TO MEET ANSI /NFPA 70 REQUIREMENTS. CABLE ARMOR TO BE INTERLOCKED STEEL METAL TAPE. MC TYPE CABLE MANUFACTURED BY AFC CABLE SYSTEMS, PIRELLI CABLE CORPORATION AND SOUTHWIRE COMPANY ARE APPROVED. MC CABLE SHALL NOT BE USED TO WIRE LIGHT FIXTURES INSTALLED IN LAY -IN OR EXPOSED CEILINGS, OR TO WIRE RECEPTACLES. 3.03 INSTALLATION OF CONDUITS: GENERAL: 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENTER LINES OF COLUMNS END BEAMS. 3. CONDUITS ABOVE CEILINGS SHOULD NOT OBSTRUCT REMOVAL OF CEILING TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED WITH MECHANICAL WORK TO AVOID ANY CONFLICT. B. CONDUIT SUPPORTS: 1. SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURE AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY CONDUIT TO MECHANICAL DUCTS OR PIPES. 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING SUPPORT WIRES WITH CADDY CLIPS ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT 15 PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG SUCH CONDUIT 50 AS NOT TO AFFECT LEVEL OF CEILING. 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT IS NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURE. C. CONDUIT PENETRATION: 1, PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING, SEAL PENETRATION WITH FIRE RETARDANT SEALANT SPECIFIED HEREIN. 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF OR EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS DETAILED ON THE DRAWINGS. 4. PENETRATING NON -FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED. PENETRATIONS MUST BE SEALED WITH PLASTER PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH 15 APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH ESCUTCHEONS, ONE ON EACH SIDE OF WALL. 5. PENETRATING SUSPENDED CEILING: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION. PROVIDE ESCUTCHEON FOR EACH CONDUIT BELOW CEILING, 3.04 CONNECTIONS TO EQUIPMENT: A. GENERAL 1. FURNISH AND INSTALL REQUIRED POWER SUPPLY CONDUIT AND WIRING TO ALL EQUIPMENT. SEE BELOW FOR OTHER WIRING REQUIRED. 2. FURNISH AND INSTALL A DISCONNECT SWITCH IMMEDIATELY AHEAD OF AND ADJACENT TO EACH MAGNETIC MOTOR STARTER OR APPLIANCE UNLESS THE MOTOR APPLIANCE IS LOCATED ADJACENT AND WITHIN SIGHT OF THE SERVING PANELBOARD, CIRCUIT BREAKER OR SWITCH. VERIFY ALL EQUIPMENT NAMEPLATE CURRENT RATINGS PRIOR TO INSTALLATION. 3. INSTALL ALL ROUGH -N WORK FOR EQUIPMENT FROM APPROVED SHOP DRAWINGS TO SUIT THE SPECIFIC REQUIREMENTS OF THE EQUIPMENT. 4. FURNISH AND INSTALL MANUAL THERMAL PROTECTION FOR ALL MOTORS NOT INTEGRALLY EQUIPPED WITH THERMAL PROTECTION. 5. FURNISH 120 VOLT POWER TO EACH CONTROL PANEL AND TIME SWITCH REQUIRING A SOURCE OF POWER TO OPERATE. 3.05 INSULATION OF WIRES: A. PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS BEEN COMPLETED. B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL. SPLICES IN CABLES WHERE REQUIRED SHALL BE MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES, MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8" OF CORRECTLY COLOR -CODED TAILS LEFT IN THE BOX. C. SPLICES IN WIRES AND CABLES SHALL BE MADE UTILIZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. D. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS TO RECEPTACLE AND WIRING DEVICE TERMINALS AS RECOMMENDED BY MANUFACTURER. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE 15 NOT APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. E. PROVIDE BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD. 3.06 WIRE COLOR CODE: COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12 THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF ANY SIZE IN CABLE ASSEMBLIES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND 120/208V BLACK RED BLUE WHITE GREEN 277/480V BROWN ORANGE YELLOW GRAY GREEN 3.07 IDENTIFICATION A. PROVIDE NAMEPLATES FAR SWITCHGEARS, PANELBOARD, AND ALL SIMILAR DEVICES. NAMEPLATES SHALL BE SCREWED (NO ADHESIVES) ENGRAVED BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION SHOWING PANEL DESIGNATORS, VOLTAGE AND PHASE IN MINIMUM 1/4" HIGH LETTERS. B. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND CIRCUIT NUMBER TO WHICH THE DEVICE IS CONNECTED. C. EACH BOARD SHALL CONTAIN A METAL- FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. D. PANELBOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANELBOARD SCHEDULES FOR ALL PANELBOARD. 3.08 GROUNDING A. ELECTRICAL SERVICE AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEMS SHALL BE GROUNDED IS ACCORDANCE WITH NEC ARTICLE 250 -3 TO 250 -26, INCLUSIVE. B. GROUND NON- CURRENT CARRYING METAL PORTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR CABLE TRAYS TO PROVIDE A LOW IMPEDANCE PATH FOR LINE -TO- GROUND FAULT CURRENT AND TO BOND ALL NON- CURRENT CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250 -95 UNLESS LARGER CONDUCTORS ARE SHOWN ON DRAWINGS. C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION. WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER SIZES, BLOCK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVICE ENCLOSURE. END OF SECTION V,19$ 9_(go 2426 Southcenter Mall Tukwila, WA 98188 smith ci. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant 6294 Consultant Registration Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 2 03.26.08 3 04.07.08 4 04.21.08 PERMIT BLDG. COMMENTS PERMIT CORR. OWNER REVISIONS KLS KLS KLS KLS RECEIVED CITY OF TUKWILA MAY 15 2008 PERMIT CENTER Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description ELECTRICAL SPECIFICATI ❑NS Computer File CW05- 2008- E3,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. E -3 FLOOR PLAN NOTES BY SYMBOL 40 VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. 006 INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T-1 LINE GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCAllON, GROUND IMRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANE OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL DE A MINIMUM SIZE OF #8 AWG THWN. .0 NOT USED PROVIDE AND INSTALL NEW 60 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. 0 PRUDE MID INSTALL NEW DISCONNECT AND ALI ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING, VERIFY LOCATION IN FIELD. C) PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL # DESCRIPTION A COOPER/METALUX 2GA332A120VEB82 2.x4' LAY-IN FLUORESCENT, T8 ENERGY SAVING 9 LITHONIA 8W1AZ INCANDESCENT RECESSED DOWNLIGHT, 8" 60 WATTS C COOPER/METALUX GA232A120VEB81 1'x4' LAY-IN FLUORESCENT, TB ENERGY SAVING X1 DUAL-LJGHT LXURWELED LJTEFORM COLLECTION EXIT LJGHTS/BATTERY BACKUP X2 SUREJTES CC7 EMERGENCY LJGHTING/BULBS INCLUDED 4 HUBBELL CS122I W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120-277V-WHITE esi HUBBELL ATP1277W PASSIVE INFRARED AND UTILJZE AS ADAPIIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY Qs E HUBBELL ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSIIIVITY NOTE: 2006 IBC — Sec. 1006 Provide an average of one foot-candle illumination at the floor along the entire egress pathway and exit discharge APPROVED PL r ICAT!ONS SI ALL r7.• CI.IA,N'GED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING Or•ICIAL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS TO Fi2L0 !N.FPECTICtIS �ri :7 0 • 0 30 T / O., . V N/ AY. 4 . . NeS7# '....,, , 4„, , , \ ''. . . . .: %, ' :. : Ai lg: ,, • r.:,,„ .... :: ,,,,,:: :: : i • .. 4 CFI A 0 1,3,5 ELECTRICAL/POWER PLAN SCALE: 1/4" = 1'--0 " ® PROVIDE NJD ftTALL NOV 60 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED aECTRICAL FROM PANE/. TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. 5 PROVIDE AND INSTALL NEW DISCONNECT AND NI ASSOCIATED ELECTRICAL FROM PANEL 10 NEW WATER HEATER ABOVE CEILJNO VERIFY LOCATION IN FELD. ®PROVIDE AND INSTALL NEW DISCCNNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.C. d',"1/71. r 34 36 FILE .COPY Permit No..*112.02:,..44,..° Plar review approval is subject to errors and omissions. Approval of construction documents does not WW2° the violation of any adopted code or ordinance. Receipt of approved Field Copy and =Mons is acknowledged: By WAN.Q.1 Date: (1101106 city of Tukwila BUILDING DIVISION EEEMEE MENEM EINIEENNE EEEEEE MENNE NINIMIEIEE 17 EINEMP.M =MINE EMMEN EEEMEE MENEM MENEM EEMEEE NEINIMINE MENEM EEEEEE • ,„ / • • •••; % ...... , • NMI EE•••E MENNEN MENNEN MENEM MENU MEMME• MENNEN MENEM EEMM EEKEEE =MEM =MEM EIEEEEE EI••IN•• EMMEN NIEMEN •INNIE EEKEEE MENEM .....ii EIREIEM ........... EEEEEE NIEMEN MUNE INE•NINEI MEM MENEM MERMEN MENNE. •IEEMEE •K••E ••NEM 1-1 ELECTRICAL/LIGHTING PLAN SCALE: 1/4" = MEANIE •E•= ••RE. 13 e c X1 •\ SEPARATE PERMIT REQUIRED FOR: Mf Mechanical- , 0 Electrical , igt Plumbing • 7. g Gas Piping ... City of Tukwila BUILDING DIVISION 2426 Southcenter Mall Tukwila, WA 98188 CO. 318 terry avenue n seethe, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http://www.smithco.org/ Consultant 6294 Consultant Registration REVISIONS No changes shall be made to the scopP of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may indudejadditionai plan review fees. i REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC • APR 10 on 111 City Of Tukwila BUILDING DM MN 11 ............ ..... ... • / • ... ............. • • 2 Issues and Revisions Architect Registration No. Date Issues By Check 02.08.08 PERMIT KLS Public Works, Building Division nrrsimrr kfl . l'ilL.44•14t-AN CITY OF TUKVVILi-k 0 8 0 PERiviiT k.:,to, ER Jim MAR 1 f ?la Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description POWER/LIGHTING PLAN Computer File CW05-2008—E1.DWG Scale AS NOTED Template 4. 3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. FILE COPY E-1 NEW PANEL B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X — -- -- SPACE 2 20,030 3 3 SPACE — — — X — — — SPACE 4 1.2 3 5 SPACE — -- — 1.25 X — -- -- SPACE 6 X 3 7 SPACE — — — X — — -- SPACE 8 3 9 SPACE — -- -- X — — — SPACE 10 11 11 WATER HEATER 750 12 2/20 X X -- — — SPACE 12 X -- -- -- SPACE 14 X — 13 750 2 15 SIGN 1200 12 1/20 X -- -- -- SPACE 16 — SPACE 17 SPACE — -- — X -- -- -- SPACE 18 19 SPACE — — — X -- -- -- SPACE 20 21 SPACE — — -- X -- -- -- SPACE 22 23 SPACE — — — X -- -- -- SPACE 24 25 SPACE — — — X — -- -- SPACE 26 27 SPACE — — -- X 1/20 12 360 GFI RECEPTACLES 28 29 SPACE -- -- -- X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE — — -- X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE — -- -- X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE — -- -- X 1/20 12 1000 GENERAL RECEPTACLES 36 37 RTU -1 3133 6 3/50 X 1/20 12 1000 GENERAL RECEPTACLES 38 X 1/20 12 1000 GENERAL RECEPTACLES 40 3133 39 X -- w.. — SPACE 42 41 3133 REMARKS TOTAL LOAD PHASE 'A' 11,108 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE '5' 11,703 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 11,363 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 34,174 WATTS MANUFACTURERS RECOMMENDATION 95 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. \-W PAS -L I LOAD TYPE Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6.0 1 VAV 1 2500 10 3/20 X 120 1/0 20,030 TRANSFORMER 2 1.5 19,150 X 3/125 4 4 4 3 2500 17,165 1.2 X 6 120 1 5 2500 1.25 7 VAV 2 2500 10 3/20 X — — _ SPACE 8 X -- — — SPACE 10 4 9 2500 X — — — SPACE 12 2500 11 13 GENERAL LIGHTING ., 1250 12 1/20 X — — — SPACE 14 15 GENERAL LIGHTING 980 12 1/20 X — — — SPACE 16 17 GENERAL LIGHTING 1345 12 1/20 X — — — SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 25,030 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 24,150 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 22,165 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 71,345 WATTS MANUFACTURERS RECOMMENDATION 86 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL_ LOAD SUvv ARY 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS • TIME CLOCK HgHHHini OVERRIDE SWITCHES • SIGN LIGHTS (B15) • t 'd' GENERAL LIGHTS (B3) OFFICE LIGHTS (B5) • OFFICE LIGHTS (B7) LIGHT SWITCHING DETAIL NOT TO SCALE • RECEPTION LIGHTS (B9) PANEL RISER 3 I A G R A V RISER DIAGRAM GENERAL NOTES LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH r-__ O - ® -1 ® LIGHTING 4.8 1.25 6.0 120 1 RECEPTACLES 15.8 1.00 12.9 120 1 WATER HEATER 1.5 1.00 1.5 208 1 MISCELLANEOUS N/A 1.00 N/A 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC 1.4 1.25 1.7 120 1 HVAC 9.4 + 25 OF LARGEST LOAD 11.9 208 .3 TOTALS: 34.1 35.5 KW = 98 6 AMPS © 120/208 SERVICE 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS • TIME CLOCK HgHHHini OVERRIDE SWITCHES • SIGN LIGHTS (B15) • t 'd' GENERAL LIGHTS (B3) OFFICE LIGHTS (B5) • OFFICE LIGHTS (B7) LIGHT SWITCHING DETAIL NOT TO SCALE • RECEPTION LIGHTS (B9) PANEL RISER 3 I A G R A V RISER DIAGRAM GENERAL NOTES FLOOR I EXISTING CONDITIONS AND PRIOR TO BIDDING AND 6 r-__ O - ® -1 ® 4 O 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 277/480V 3 PH, 4 WIRE ELECTRICAL SERVICE 7 "70 ] , 0j7, ©h VERIFY REQUIREMENTS INSTALLATION. RISER DIAGRAM NOTES BY SYV1BOL 0 1 EXISTING ELECTRICAL 1 DISTRIBUTION SYSTEM(S) FOR OTHER TENANTS L J 1 1 1 I 1 p I 1 i I I I TENANT @ PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. O PROVIDE AND INSTALL METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS. ® PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUIT. ® PROVIDE AND INSTALL (4) #1/0 11-IWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'H'. V PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU- -1 ON ROOF. 0 PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU -2 ON ROOF. ® PROVIDE AND INSTALL 30 AMP DISCONNECT FOR RTU -1 ON ROOF. VERIFY LOCATION IN HELD. ® PROVIDE AND INSTALL 30 AMP DISCONNECT FOR RTU -2 ON ROOF. VERIFY LOCATION IN FIELD. 10 NOT USED 11 PROVIDE AND INSTALL (3) #1/D THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER. 12 PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. 0 PROVIDE AND INSTALL (3) #3/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'A'. 14 PROVIDE AND INSTALL 24 HR, 7 DAY 11MECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS REQUIRED NEW PANEL NEW PANEL © EXISTING LANDLORD WIREWAY ® e iVr- LANDLORD PROVIDE AND INSTALL GROUND TO BUILDING STEEL PER N.E.C. S 9-iP0 REViEVVED FOR CODE COMPLIANCE NFPA 70 - NEC APR 10 MB City Of Tukwila BUILDING DIVISION: 2426 Southcenter Mall Tukwila, WA 98188 mita co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant 6294 REGISTERED ARCI-VWECT STATE OF WASHINGTON Consultant Registration Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 PERMIT KLS RECEII ,�Dngi A CITY Or MAR 11 t003 PERMIT GtIVTER Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ile. E -2 PART 1 - GENERAL 1.01 SCOPE OF WORK: FURNISH AND INSTALL ALL EQUIPMENT AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENT AND SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND /OR SPECIFIED HEREIN. ALSO ARE INCLUDED ALL OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION INCLUDING ALL ACCESSORIES AND APPURTENANCE REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWING AND SPECIFICATIONS THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. 1.02 REGULATORY REQUIREMENTS CODE COMPLIANCE IS MANDATORY. NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMITS WORK AND NOT CONFORMING TO THESE CODES. WHERE WORK 1S SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (OSH). 2. NFPA #70; NATIONAL ELECTRIC CODE (NEC). 3. NFPA #101: LIFE SAFELY CODE. 4, STATE FIRE MARSHAL 5. LOCAL UTILITIES COMPANIES. 6. ALL LANDLORD GENERAL REQUIREMENTS FOR MALL. 1.03 LICENSE. FEES AND PERMITS: ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMITS AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. 1.04 SAFETY AND INDEMNITY: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. NO ACT, SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER. THE ENGINEERS OR THEIR CONSULTANTS, IS INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, OR NEAR THE CONSTRUCTION SITE. 1.05 DRAWINGS AND SPECIFICATIONS: ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF TI-115 DIVISION SHOW ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENTS SHALL BE GOVERNED BY CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS, WHETHER SPECIFICALLY MENTIONED OR NOT. 1.06 CONDITIONS AT SITE: THE ELECTRICAL CONTRACTOR SHALL HAVE EXAMINED THE SITE AND FAMILIARIZED THEMSELVES WITH ALL DISCERNIBLE EXISTING CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS SHALL BE INCLUDED IN THE BID. 1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF WORK. THE CONTRACTOR SHALL BE A LICENSED MASTERED ELECTRICIAN OF THE STATE IN WHICH THE JOB 15 LOCATED. 1.08 SHOP DRAWINGS AND MATERIALS LISTS: SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS LISTS, AS NOTED BELOW, FOR REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. SUBMITTALS REQUIRED AS FOLLOWS: 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. 2. ENCLOSURES FOR UTILITY COMPANY METERING. 3. MAIN FUSED DISCONNECT SWITCH. 4. PANELBOARDS 5. DISCONNECT SWITCHES 6. LIGHT FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. 1.09 SUBSTITUTIONS: ONE OF MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION IS PERMITTED. NO WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE OWNER. THE OWNER 15 THE SOLE JUDGE OF ACCEPTABIUTY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM IS PERMITTED, AND ANY RE- DESIGN EFFORT IS THEREBY NECESSITATED, THE REQUIRED RE- DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.10 COORDINATION: COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH -IN AND CONNECTION FOR EQUIPMENT FURNISHED UNDER OTHER TRADES THAT REQUIRED ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES THAT REQUIRE ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABIUTY AND CODE COMPLIANCE. VERIFY EQUIPMENT DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. 1.11 CUTTING AND PATCHING: ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION IS INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND OTHER TRADES IS IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER HOLES, SUPPORTS, ETC. 1.12 ACCEPTANCE DEMONSTRATION: UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR OWNER THE OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. PROPERTY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND /OR TEST TIME SWITCHES PROGRAMMING. 1.13 RECORD DRAWINGS, EQUIPMENT DATA: MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH AS-BUILT INFORMATION AS FEEDER AND SERVICE ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION. DELIVER COMPLETED DRAWINGS TO THE OWNER. DELIVER TO THE OWNER'S REPRESENTATIVE THREE COPIES OF DATA SHEETS OR OTHER CURRENT MANUFACTURERS PUBLICATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT INCLUDING AT LEAST THESE DATA: 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS LIST. 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. 3. USER'S MANUAL AND OPERATING INSTRUCTIONS. 4. MANUFACTURER'S WARRANTY. 1.14 CLEANUP RID THE PREMISES OF SCRAP MATERIALS, TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. 1.15 GUARANTEE: GUARANTEE THE INSTALLATION FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHANGE. 1.16 TEMPORARY SERVICES: PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE PREMISES FOR BENEFICIAL OCCUPANCY. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: 1. THREE 20 -AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE GF1 TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA REQUIREMENTS. 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARAI 1 FL TO THE DEMISING WALLS, WITH ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN ROWS TO SIXTEEN FEET OR LESS. 3. FLOOD LIGHTING AND TASK LIGHTING FOR PAINTING AND OTHER FINISH WORK. WHEN PERMANENT ELECTRICAL SERVICE IS OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT USED FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR REMOVAL OF TEMPORARY SERVICE PROVISIONS. 1.17 OWNER-FURNISHED ITEMS: CONTRACTOR SHALL INSTALL, CONNECT AND COMPLETE THE FOLLOWING ITEMS FURNISHED BY THE OWNER AND SHALL PROVIDE WIRES, CABLES, CONNECTORS, PIGTAILS, CORDS AND CORD -CAPS, BOXES, CONDUIT, PLATES, SUPPORTS, AND. OPERATING TESTS TO MAKE COMPONENTS AND SYSTEMS OPERATE SATISFACTORILY. PROVIDE SYSTEMS DRAWING FROM THE MANUFACTURER THROUGH THE OWNER IN ORDER TO INSTALL COMPLETE OPERABLE SYSTEM. 1. MUSIC SOUND SYSTEM COMPONENTS. 2. ENTRY ALARM SYSTEM CONTROL PANEL AND CONTACTS /SECURITY SYSTEMS. PART 2 - PRODUCTS 2.01 MATERIAL APPROVAL ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITER'S LABORATORIES LABEL MATERIALS THAT ARE NOT COVERED BY UL TESTING STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AFTER INSTALLATION. 2.02 CONDUITS AND OTHER RACEWAYS: A. RIGID STEEL: HOT- DIPPED GALVANIZED. B. INTERMEDIATE METAL CONDUIT (IMC): HOT- DIPPED GALVANIZED C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO- GALVANIZED. D. WIREWAY CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND OUTDOORS. 2.03 WIRES AND CABLES: A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: 1. CONDUCTOR: MINIMUM SIZE #12 A. #12 AND #10 AWG SOLID COPPER. B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. 2. INSULATION TYPE: A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THWN FOR DRY LOCATIONS. B. #10 THROUGH #4/0 AWG: XHHW (55 MILS). C. #250 MCM AND LARGER XHHW (65 MILS). D. GROUNDING WIRE: TW. B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #16 AWG MINIMUM, WITH THWN INSULATION FOR UNDERGROUND OR WET LOCATIONS AND THHN INSULATION FOR DRY LOCATIONS. C. ACCEPTABLE PRODUCTS GENERAL ELECTRIC, ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING APPUCABLE IKEA STANDARDS. 2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: A. OUTLET BOXES: 4" SQUARE X 1 - 1/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO -TYPE WITH PLASTER RING AND COVER FOR GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). B. JUNCTION BOXES SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE- GAUGE STEEL IN LARGER SIZES WITH SURFACE OR FLUSH -TYPE SCREW - MOUNTED TRIM COVERS, BOTH BOXES AND COVERS INHIBITOR - PRIMED) AND PAINTED INSIDE OUT. C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN 4- 11/16" SQUARE X 2 -1/8" DEEP WITH SINGLE -GANG RING AND SIERRA #S -754N SPLIT PLATE BUSHING. E. ALL BOXES AND ASSOCIATED COMPONENTS SHALL BE STEEL CITY 683 SERIES, WITH P60 -3B COVERPLATE. 2.05 WIRING DEVICES AND PLATES: WIRING DEVICES AND PLATES SHALL BE HUBBELL. ARROW HART, GE OR P &5 WITH HUBBELL NUMBERS USED TO SPECIFY TYPE USED. STANDARD DESIGN: A. SWITCH AND RECEPTACLES DEVICES SHALL BE IVORY EXCEPT WHEN THE DEVICE IS LOCATED ORE A PURPLE WALL, WHEN ON PURPLE WAIL DEVICE SHALL BE BLACK B. ISOLATED GROUND RECEPTACLES SHALL BE WHITE WITH ORANGE TRIANGLE AS REQUIRED PER NEC, MANUFACTURED BY LEVITON # 5362 -IGW OR APPROVED EQUAL C. SWITCHES SHALL BE 20 AMP, 120/277 VOLT A.C. RATED SINGLE POLE SWITCHES SHALL BE #1221 AND 3 -WAY SWITCHES SHALL BE #1223. D. RECEPTACLES SHALL BE GROUNDING TYPE #5362. 2.06 CONDUIT HANGERS: FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR POWERSTRUT. FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM DEFLECTION NOT GREATER THAN 1/8" 2.07 WIRE CONNECTORS: FOR WIRE SIZES #8 AWG AND SMALLER INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C. 600V, FOR BUILDING WIRING AND 1000W IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL FOR WIRE SIZE #6 AWG AND LARGER T & B OR EQUIVALENT COMPRESSION TYPE WITH 3M 03 OR PLYMOUTH "SLIPKNOT GRAY" TAPE INSULATION. 2.08 PANELBOARD: A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL BE OF COLD - ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20 ". FINISH EXPOSED PART WITH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GRAY ENAMEL SUITABLE FOR OVER PAINTING IN FIELD IT DESIRED. B. BUS BARS: PROVIDE GROUND BLOCK WITH FULL COMPLEMENT OF TERMINALS IN ADDITION TO INSULATED NEUTRAL BUS. FUTURE BREAKER SPACES SHALL HAVE COMPLETE PROVISION INCLUDING BUSSES AIR CONNECTING HARDWARE. C. MANUFACTURER PANELBOARD SHALL IN GENERAL ELECTRIC TYPE AQ OR TYPE AE OR EQUIVALENT PRODUCTS OF CUTTER- HAMMER, SQUARE D, OR SIEMENS -ITE. D. CIRCUIT BREAKERS SHALL BE BOLT -ON, THERMAL- MAGNETIC, MOLDED CASE TYPE: U.L. LISTED FOR SWITCHING DUTY. BREAKERS SHALL HAVE ON OVER- CENTER TRIP FREE, TOGGLE TYPE HANDLE WITH QUICK -MAKE, QUICK -BREAK ACTION. 1. 120/208 VOLT PANELS: SHALL BE GENERAL ELECTRIC TYPE "Q" LINE, BOLT -ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING CAPACITY AS SHOWN. NO SERIES RATING ALLOWED. 2. PROVIDE MULTI -POLE UNITS WITH COMMON TRIP ELEMENT. 3. CIRCUIT BREAKERS USED ON "ON -OFF" CONTROL OF FLUORESCENT UGHTING ( PANELBOARD SWITCHING) SHALL BE UNDERWRITERS - LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABILITY. E. IDENTIFICATION: PROVIDE SCREWED -ON (NO ADHESIVES) BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIF1CA11ON AN OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE, AND PHASE IN MINIMUM 1/4" HIGH LETTERS. EACH PANEL SHALL CONTAIN A METAL- FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. F. COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. 2.09 DRY TYPE TRANSFORMER: A. GENERAL: EQUIPMENT SHALL CONFORM TO OR EXCEED REQUIREMENTS OF NEMA, ANSI STANDARD C89.2 FOR DRY TYPE TRANSFORMERS FOR GENERAL APPLICATIONS. ACCEPTABLE PRODUCTS ARE THOSE OF GENERAL ELECTRIC COMPANYS "QHT" LINE OR EQUIVALENT SQUARE D, SIEMENS -ITE, OR CUTTLER- HAMMER. ELECTRICAL RATINGS: 1. PRIMARY WINDINGS VOLTAGE 480 VOLTS, 3- PHASE, DELTA. SECONDARY WINDING VOLTAGES 208Y/120 VOLTS, .3-PHASE GROUNDED. FREQUENCY: 60 HZ. KVA RATING: AS SHOWN ON DRAWINGS. TOPS: SIX (6) 2.5% FULL CAPACITY TAPS, 2 ABOVE AND 4 BELOW, RATED VOLTAGE. IMPEDANCE: FOR TRANSFORMERS LARGER THAN 75 KVA, 4.5% MINIMUM, 5.75 MAXIMUM 2. WINDING TEMPERATURE RISE SHALL BE 150 DEGREES CENTIGRADE IN ACCORDANCE WITH UL SPECIFICATION ARTICLE 506. 3. TRANSFORMER SHALL BE CAPABLE OF OPERATING AT 100% OF NAMEPLATE RATING CONTINUOUSLY WHILE IN AN AMBIENT TEMPERATURE NOT EXCEEDING 40 DEGREES CENTIGRADE. 4. TRANSFORMER SHALL MEET THE DAILY OVERLOAD REQUIREMENTS OF ANSI STANDARD C57.96. C. VIBRATION ISOLATION, FACTORY- INSTALLED: PROVIDE NEOPRENE RUBBER PADS TO ISOLATE CORE AND COIL ASSEMBLY FROM TRANSFORMER ENCLOSURE. D. INSTALLATION: 1. ANCHOR TRANSFORMER SECURITY WITH MINIMUM 1/2" DIAMETER BOLTS. STRENGTH OF BOLTS USED TO SECURE THE TRANSFORMER SHALL BE SUFFICIENT TO RESIST SHEAR AND UPLIFT PRODUCED BY FORCE EQUAL TO 1/2 OF THE EQUIPMENT MASS APPLIED HORIZONTALLY AT ENTER OF GRAVITY. 2. PROVIDE 1 THICK HIGH RESIDENCY PADS TO ISOLATE TRANSFORMER FROM FLOOR OR PLATFORM. KORFUND "ELASTO RIB" OR EQUIVALENT. 3. USE FLEXIBLE CONDUITS AT LEAST 24" LONG FOR ELECTRICAL CONNECTIONS. 4. PROVIDE GROUNDING OF EACH TRANSFORMER SECONDARY INCLUDING ALL CONDUITS. WIRES, AND CONNECTORS IN ACCORDANCE WITH NEC 250 -26 AND ANY LOCAL ADDITIONAL REGULATIONS. 2.10 INDIVIDUALLY MOUNTED MOTOR CONTROLLER: A. FOR POLYPHASE MOTORS: COMBINATION MOTOR CIRCUIT PROTECTOR AND MAGNETIC STARTER, WITH 3 -LEG OVERLOAD PROTECTION. PROVIDE TWO INTERLOCK CONTACTS OF THE INTERCHANGEABLE OPEN -CLOSE TYPE. PROVIDE HAND -OFF AUTOMATIC SELECTOR SWITCH, MOTOR RUNNING PILOT LIGHT AND RESET BUTTON IN COVER. CIRCUITS 300V AND OVER SHALL BE PROVIDED WITH INDIVIDUAL 120V CONTROL TRANSFORMERS. B. STARTERS FOR FRACTIONAL HORSEPOWER 120V MOTORS SHALL BE MANUAL TYPE UNLESS SHOWN OTHERWISE, EQUIPPED WITH BUILT -IN OVERLOAD PROTECTION. C. ACCEPTABLE MANUFACTURERS GENERAL ELECTRIC SIEMENS, SQUARE D, CUTTER - HAMMER, AND ALLEN BRADLEY. 2.11 UGHTING A. LIGHTING TO BE PROVIDED BY OWNER. SUBCONTRACTORS TO INSTALL ALL FIXTURES COMPLETE, INCLUDING LAMPS AND BALLASTS, READY FOR SERVICE. B. SUPPORTS: PROPER SUPPORTS AND MOUNTING ACCESSORIES, SUCH AS HANGERS, STEMS, YOKES, PLASTER FRAMES, ETC SHALL BE PROVIDED AS REQUIRED BY THE TYPE OF CEILING INSTALLED. WHERE SWIVEL CANOPIES OR BALL AUGNERS ARE SPECIFIED, THEY SHALL CAUSE FIXTURE TO HANG PLUMP REGARDLESS OF CEILING SLOPE. C. FIXTURE DESIGNATION: FIXTURE TYPES ARE DESIGNATED ON DRAWINGS, WHERE ONLY ONE FIXTURE DESIGNATION IS SHOWN, IT APPLIES TO ALL FIXTURES IN THAT ROOM OR AREA. FOR EXACT FIXTURE COUNT AND LOCATION REFER TO REFLECTED CEILING PLAN. D. WIRE 1 -LAMP AND 3 -LAMP FLUORESCENT FIXTURES IN TANDEM WHERE REQUIRED BY CODE. E. BALLASTS: ADVANCE, GE, OR APPROVED HIGH FREQUENCY ELECTRONIC, FULL LIGHT OUTPUT, ENERGY SAVING, CLASS "P ", HIGH POWER FACTOR. ETL CERTIFIED, SOUND RATING "A" OR AS INDICATED ON DRAWINGS. 2.12 MISCELLANEOUS MATERIALS: A: SAFETY SWITCHES: HEAVY DUTY TYPE, 600V, HORSEPOWER RATED FOR MOTORS, FUSED OR NON -FUSED AS REQUIRED. MOUNT IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR CUTLER - HAMMER. PART 3 - EXECUTION 3.01 GENERAL A. ELECTRIC SYSTEM LAYOUTS INDICATED ON THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. GOVERN EXACT ROUTING OF CABLE AND WIRING AND THE LOCATIONS OF OUTLETS BY THE STRUCTURE AND EQUIPMENT SERVED. TAKE ALL DIMENSIONS ROM ARCHITECTURAL DRAWINGS. B. CONSULT ALL OTHER DRAWINGS, VERIFY SCALES AND REPORT ANY DIMENSIONS, DISCREPANCIES OR OTHER CONFLICTS WITH OWNER BEFORE SUBMITTING BID. C. ALL HOME RUNS TO PANELBOARDS ARE INDICATED AS STARTING FROM THE OUTLET NEAREST THE PANEL AND CONTINUING IN THE GENERAL DIRECTION OF THAT PANEL CONTINUE SUCH CIRCUITS TO THE PANEL AS THOUGH THE ROUTES WERE COMPLETELY INDICATED. TERMINATE HOMERUNS OF SIGNAL, ALARM, AND COMMUNICATION SYSTEMS IN A SIMILAR MANNER. D. AVOID CUTTING AND BORING HOLES THROUGH STRUCTURE OR STRUCTURAL MEMBERS WHEREVER POSSIBLE. OBTAIN PRIOR APPROVAL OF OWNER AND CONFORM TO ALL STRUCTURAL REQUIREMENTS WHEN CUTTING OR BORING THE STRUCTURE 15 NECESSARY AND PERMITTED. E. FURNISH AND INSTALL ALL NECESSARY HARDWARE, HANGERS, BLOCKING, BRACKETS, BRACING, RUNNERS, ETC. REQUIRED FOR EQUIPMENT SPECIFIED UNDER THIS SECTION. F. PROVIDE NECESSARY BACKING REQUIRED TO INSURE RIGID MOUNTING OF OUTLET BOXES, 3.02 WIRING METHODS: A. NO 'ROMEX' OR 'BX' WIRING 15 PERM! I IED - ALL ELECTRICAL WIRING MUST BE IN CONDUIT. B. CONDUIT SHALL BE RIGID STEEL, IMC OR EMT AS FOLLOWS: 1. ABOVE GROUND: USE RIGID STEEL IMC OR EMT. A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. B. LOCATIONS SUBJECT TO MECHANICAL INJURY: RIGID STEEL OR IMC ONLY. C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMC OR RIGID STEEL CONDUIT 2. UNDERGROUND: USE RIGID STEEL. C. USE FLEXIBLE CONDUITS IN THE FOLLOWING APPLICATIONS. 1. RECESSED LIGHTING FIXTURES. 2. MOTOR CONNECTIONS. 3. AT BUILDING JOINTS AND WET LOCATIONS, FLEXIBLE CONDUIT SHALL BE LIQUID TIGHT TYPE. D. LIGHT FIXTURES INSTALLED IN SHEETROCK CEILINGS MAY BE WIRED FROM FIXTURE TO FUTURE USING METAL CLAD (MC) CABLE. VERIFY THAT LIGHT FIXTURES ARE PROVIDED WITH JUNCTION BOXES APPROVED FOR THIS PURPOSE. MC TYPE CABLE TO MEET ANSI /NFPA 70 REQUIREMENTS. CABLE ARMOR TO BE INTERLOCKED STEEL METAL TAPE. MC TYPE CABLE MANUFACTURED BY AFC CABLE SYSTEMS, PIRELLI CABLE CORPORATION AND SOUTHWIRE COMPANY ARE APPROVED. MC CABLE SHALL NOT BE USED TO WIRE LIGHT FIXTURES INSTALLED IN LAY -IN OR EXPOSED CEILINGS, OR TO WIRE RECEPTACLES. 3.03 INSTALLATION OF CONDUITS: GENERAL 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENTER LINES OF COLUMNS END BEAMS. 3. CONDUITS ABOVE CEILINGS SHOULD NOT OBSTRUCT REMOVAL OF CEILING 'TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED WITH MECHANICAL WORK TO AVOID ANY CONFLICT. B. CONDUIT SUPPORTS: 1, SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURE AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY CONDUIT TO MECHANICAL DUCTS OR PIPES. 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING SUPPORT WIRES WITH CADDY CUPS ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT IS PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG SUCH CONDUIT 50 AS NOT TO AFFECT LEVEL OF CEILING. 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT 15 NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURE. C. CONDUIT PENETRATION: 1. PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING. SEAL PENETRATION WITH FIRE RETARDANT SEALANT SPECIFIED HEREIN. 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF OR EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS DETAILED ON THE DRAWINGS. 4. PENETRATING NON -FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED, PENETRATIONS MUST BE SEALED WITH PLASTER PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH IS APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH ESCUTCHEONS, ONE ON EACH SIDE OF WALL. 5. PENETRATING SUSPENDED CEILING: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION. PROVIDE ESCUTCHEON FOR EACH CONDUIT BELOW CEILING. 3.04 CONNECTIONS TO EQUIPMENT: A. GENERAL 1. FURNISH AND INSTALL REQUIRED POWER SUPPLY CONDUIT AND WIRING TO ALL EQUIPMENT. SEE BELOW FOR OTHER WIRING REQUIRED. 2. FURNISH AND INSTALL A DISCONNECT SWITCH IMMEDIATELY AHEAD OF AND ADJACENT TO EACH MAGNETIC MOTOR STARTER OR APPLIANCE UNLESS THE MOTOR APPLIANCE IS LOCATED ADJACENT AND WITHIN SIGHT OF THE SERVING PANELBOARD, CIRCUIT BREAKER OR SWITCH. VERIFY ALL EQUIPMENT NAMEPLATE CURRENT RATINGS PRIOR TO INSTALLATION. 3. INSTALL ALL ROUGH -N WORK FOR EQUIPMENT FROM APPROVED SHOP DRAWINGS TO SUIT THE SPECIFIC REQUIREMENTS OF THE EQUIPMENT. 4. FURNISH AND INSTALL MANUAL THERMAL PROTECTION FOR ALL MOTORS NOT INTEGRALLY EQUIPPED WITH THERMAL PROTECTION. 5. FURNISH 120 VOLT POWER TO EACH CONTROL PANEL AND TIME SWITCH REQUIRING A SOURCE OF POWER TO OPERATE. 3.05 INSULATION OF WIRES: A. PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS BEEN COMPLETED. B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL SPLICES IN CABLES WHERE REQUIRED SHALL BE MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES. MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8" OF CORRECTLY COLOR -CODED TAILS LEFT IN THE BOX. C. SPUCES IN WIRES AND CABLES SHALL BE MADE UTILIZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS RECEPTACLE AND WRING TERMINALS 1RAL 110NS TO RECE ING DEVICE TERM LS AS RECOMMENDED BY MANUFACTURER. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE IS NOT APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. E. PROVIDE BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD. 3.06 WIRE COLOR CODE: COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12 THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF ANY SIZE IN CABLE ASSEMBLIES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND 120/208V BLACKRED BLUE WHITE GREEN 277/460V BROWN ORANGE YELLOW GRAY GREEN 3.07 IDENTIFICATION A. PROVIDE NAMEPLATES FAR SWITCHGEARS, PANELBOARD, AND ALL SIMILAR DEVICES. NAMEPLATES SHALL BE SCREWED (NO ADHESIVES) ENGRAVED BAKELITE OR PHOTO - ETCHED METALLIC NAMEPLATE IDENTIFICATION SHOWING PANEL DESIGNATORS, VOLTAGE AND PHASE IN MINIMUM 1/4" HIGH LETTERS. B. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND CIRCUIT NUMBER TO WHICH THE DEVICE 15 CONNECTED. C. EACH BOARD SHALL CONTAIN A METAL- FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. D. PANELBOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANELBOARD SCHEDULES FOR ALL PANELBOARD. 3.08 GROUNDING A. ELECTRICAL SERVICE AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEMS SHALL BE GROUNDED IS ACCORDANCE WITH NEC ARTICLE 250 -3 TO 250 -26, INCLUSIVE. B. GROUND NON- CURRENT CARRYING METAL PORTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR CABLE TRAYS TO PROVIDE A LOW IMPEDANCE PATH FOR UNE- TO- GROUND FAULT CURRENT AND TO BOND ALL NON- CURRENT CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250 -95 UNLESS LARGER CONDUCTORS ARE SHOWN ON DRAWINGS. C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION. WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER SIZES, BLOCK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVICE ENCLOSURE. END OF SECTION "E170S Zeo REVI- EVVED l~O CE NFPA CODE COMPLIANCE 70 - NEC APR i U 2FJt3 City Of Tukwila B ILD NG DIVI ION 2426 Southcenter Mall Tukwila, WA 98188 smith c*. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithco.org/ Consultant 6294 Consultant Registration Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 PERMIT KLS RE E,i t 1. UT( OF MAR PERMIT GEN 1'ER Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description ELECTRICAL SPECIFICATIONS Computer File CW05- 2008- E3,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. E -3