Loading...
HomeMy WebLinkAboutPermit EL08-0262 - WESTFIELD SOUTHCENTER MALL - INDUSTRIAL RIDE SHOPINDUSTRIAL RIDE SHOP 2856 SC MALL 07-22-08 ELO8-262 Parcel No.: Address: Suite No: CitAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 6364200010 2856 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: EL08 -262 05/07/2008 01/12/2009 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: INDUSTRIAL RIDE SHOP 2856 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA KEITH SMITH 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: Phone: 206 713 -4076 Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: PROVIDE NEW SERVICE, PANELS, AND TRANSFORMER AND LIGHTING Value of Electrical: Type of Fire Protection: $26,000.00 SPRINKLERS /AFA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: ()J, $751.50 2005 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting construction Signa Print Name: permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating e performance of work. I am authorized to sign and obtain this electrical permit. 1.13-(1-&15. )3,9,f'e_ Date: f 121 o g This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -262 Printed: 07 -23 -2008 CitAbf Tukwila • Department of `Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2856 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -262 Issue Date: 05/07/2008 Permit Expires On: 11/03/2008 Tenant: Name: WESTFIELD - VANILLA BOX Address: 2856 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 713 -4076 Address: 1725 WESTLAKE AV N, STE 210 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: PROVIDE NEW SERVICE, PANELS, AND TRANSFORMER AND LIGHTING Value of Electrical: $25,000.00 Fees Collected: $615.00 Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: �i1/L ! 0' Date: I hereby certify that I have read and x ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: L c C tux. ON( X e- Date: os l 6?. (06 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -262 Printed: 05 -07 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2856 SOUTHCENTER MALL TUKW INDUSTRIAL RIDE SHOP Permit Number: Status: Applied Date: Issue Date: EL08 -262 ISSUED 03/17/2008 05/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating co ction or the performance of work. Signatur Print Name: L bY'e,Y\a■ Dater 2-7-7 O doc: Cond -Elec EL08 -262 Printed: 07 -23 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2856 SOUTHCENTER MALL TUKW WESTFIELD - VANILLA BOX Permit Number: Status: Applied Date: Issue Date: EL08 -262 ISSUED 03/17/2008 05/07/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: V3 J Date: CS 1 Un I v t uPrint Name: "' e ` 9, v oil a doc: Cond -Elec EL08 -262 Printed: 05 -07 -2008 Site Address: CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 h ttp: //www. ci. t kwil a. wa. us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Co Assessor's Tax No.: Z,d) 21-1-6/ > Suite Number: D Floor: w Tenant: ,,;_Yes ❑..No Tenant Name: Property Owners Name: Mailing Address: log Name: Mailing Address: E -Mail Address: ay Telephone: /CL't ' 7/3 t 5141 71 cm//A t22 rl I O7 Oc Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ Scope of Work (pl-ase provide detaile. information Will service be altered? Ye ❑ No Type of Use: t Type of work: ❑ New ❑ Addition ❑ Low Voltage ❑ Generator Property Served by: { Puget Sound Energy ❑ eattle City Light Adding more than 50 amps? j Yes ❑ No ❑ Service Change ❑ Remodel grTenant Improvement ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service H:\Applications\Potms- Applications On Line \4 -2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter/mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW ER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: "till IL miss= (12 (NA Date Application Accepted: Day Telephone: five yyi•ct_ 910 Date Application Expires: Staff Initials: H:Wpplications \Forms - Applications On line \4 -2007 - Electrical Permit Application.doc bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: INDUSTRIAL RIDE SHOP City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.atukwila.wa.us 6364200010 2856 SOUTHCENTER MALL TUKW RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -262 ISSUED 03/17/2008 05/07/2008 Receipt No.: R08 -02714 Initials: WER User ID: 1655 Payee: Payment Amount: $78.50 Payment Date: 07/23/2008 09:27 AM Balance: $0.00 SME OF SEATTLE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21199 78.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 74.40 4.10 Total: $78.50 doc: Receiot -06 Printed: 07 -23 -2008 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 2856 SOUTHCENTER MALL TUKW WESTFIELD - VANILLA BOX RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -262 ISSUED 03/17/2008 05/07/2008 Receipt No.: Initials: User ID: R08 -02275 WER 1655 Payment Amount: $58.00 Payment Date: 06/24/2008 03:01 PM Balance: $0.00 Payee: SME INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21154 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 4049 06/24 9711 TOTAL 406.00 doc: Receiot -06 Printed: 06-24 -2008 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01513 Initials: WER User ID: 1655 Payee: SME, INC. OF SEATTLE Payment Date: 05/07/2008 Total Payment: 1,968.00 SET ID: 0507 SET NAME: WESTFIELD VANILLA BOXES SET TRANSACTIONS: Set Member Amount ELOB -260 492.00 EL *0'8 -"2'6 492.00 492.00 EL08 -354 492.00 TOTAL: 1,968.00 TRANSACTION LIST: Type Method Description Amount Payment Check 21088 1,968.00 TOTAL: 1,968.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,968.00 TOTAL: 1,968.00 2106 05/07 9711 TOTAL 1968.00 M City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431 -3665 Web site: http. //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -00798 Initials: JEM Payment Date: 03/17/2008 User ID: 1165 Total Payment: 1,144.16 Payee: ERIK S BARTH SET ID: S000000983 SET TRANSACTIONS: Set Member Amount D08 -144 881.66 EDO :8= -262 123.00 ea. MrOB" 2 101.50 PGO8 -085 38.00 TOTAL: 1,144.16 TRANSACTION LIST: Type Method Description SET NAME: Tmp set/Initialized Activities Payment Check 216 ACCOUNT ITEM LIST: Description TOTAL: Amount 1,144.16 1,144.16 Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 123.00 000/345.830 1,021.16 TOTAL: 1,144.16 INSPECTION NO. INSPECTION RECORD_ 2422. Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: vi JJ 6 AAI ILIA 0X Type of Inspection: Z-100 Address: 21,5 / �! b raw Date Called: Special Instructions: Date Wanted: —7/;7- �.. Requester: Phone No: 1444. Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: _SI &Awe( Date: 07 /7 210t ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Rbtain a'`copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION p2- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3E470 Project: /0-i< 1 Vf!'f1i' Type of \.� 16 Add sC AM / /' (ri Date Called: ler //AWL 16 WI Instructions: Date Wanted: a.m. p.m. Requester: Phone No: 12 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: ,$ P W, b( m&-3-o. / ./347,77 FY /4/4( V 7JCC /3AM ( /i/9KE CCGio25 II Ct/' 7 f c -L f /n) / <7-40 n ler //AWL 16 - ( 2C eX W S7 Inspe o „5 /adab' $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPEC ION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit 61,(1_ 2(04 PERMIT NO. Project: V 441 Wa 60/ Type of Inspection: 1003 Address: 2-v VP tilki Date Called: OJ.- cL I L jnl coutic Special Instructions: Date Wanted: a:m: Requester: D i s c.b anlltGr- Phone No: EiApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Yik- OJ.- cL I L jnl coutic TRfii.0. C'.4 c �Ov1" k-T /A V ACC. s IM�i&ott 5dPocr of D i s c.b anlltGr- Inspector:t &I/06c Date: El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: A aQb�aa — .CnaL INSPECTION RECORD Retain a copy with permit I PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 L:t o'- Z(91 Project: V { L fl / Type of Inspection: 7003 Address:,n �(p 1, 4_ Date Called: Special Instructions: Date Wanted: ! J�� (Fi/ 41> m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: g - Attu D•midpett $ 772, a font r, CoLJ> .,5 Inspector: _Till be-A/A& Date: 0(0/25., /o\g / J { El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project: � 1/4/1/4M ' KJ / Type of Inspection: -^� 9� Z3. AdS dres c PI 0 V 77/4.0,714 44., Date Called: Special Instructions: Date Wanted: !1 p.m. Requester: Phone No: 74° I Approved per applicable codes. I Corrections required prior to approval. COMMENTS: /W. 0§ WW1-. 4/45 Inspe Datebkzbee." Ej $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 4 Project:I 004 6,e Type of Inspection: 7D°3 Address: /!_ Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: 0,1(-„or (ft) C'ST Inspector: Date: 0 Z ii(3,6• D $58.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Ews -zbz1 PERMIT NO. Project: J4J I Type of Inspection: 7t7o2._ Address: 2 Y ` 6. Date Called: Special Instructions: Date Wanted: (�a.rTjs m. Requester: i�'� Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: Date: O5/ � El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION Q+ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: \it,i4i(A,4, 59‹ Type of Inspection: 700?.— Address:jg5_( tiartt, Date Called: ,, Special Instructions: Date Wanted: 51( 14 (a.m P.m. Requester: lllffl Phone No: 0 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: !or LC. b Inspector: 6r-hblek Date: 05 ci o.t $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: ti INSPECTION RECORD Retain a copy with permit INSPECTION NO. P IT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1 00, Tukwila, WA 98188 (206)431 -3670 Project: Type of Inspection: 70 7)1 Address ! 1. ,� Date Called: Special Instructions: Date Wanted: ` Requester: Phone No: pproved per applicable codes. Corrections required prior to approval. COMMENTS: /DA_ ()IL- kilo- Ne_ci InspectoV / l L `l3Y / #f4/ Date: ri7-k r $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 2006 Washin.ton State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 2856 Southcenter Mall Date 3/16/2008 Tukwila, WA 98188 For Building Department Use Applicant Name: Keith smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC APR 1 u 2008 RECEIVED CITY OF TUKVVILA MAR 17 2008 ALEtOP PERMIT CENTER •61.Og-2102 2006 Washington State Nonresidential Energ Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 2856 Southcenter Mall Date 3/16/2008 Tukwila, WA 98188 For Building Department Use 101 Applicant Name: Keith smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 Project Description 103 • New Building . Addition Alteration 'a Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 0.80 130.0 • No changes are being made to the lighting 104 • Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per f2 ** Area in fe Allowed x Area 101 retail 1.50 2101.0 3151.5 103 stock room 0.50 475.0 237.5 104 toilet 0.80 130.0 104.0 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watt 3493.0 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 Ll - CANOPY MTD. LINEAR FLUORESCENT 16 96.0 1536.0 101 12 - RECESSED FLUORESCENT 11 26.0 286.0 103 Ll - CANOPY MTD. LINEAR FLUORESCENT 4 96.0 384.0 104 Ll - CANOPY MTD. LINEAR FLUORESCENT 2 96.0 192.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watt 2398.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the Tamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Form Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers Q Other ualification Checklist Q Note: If occupancy type is "Other" and fodure answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. fl not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) 0.9 II Check if 95% /e or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic balsas 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (1LPA s Use' LPA (W /sf) Use' LPA7 (Wlsf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches) " 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments°, restaurants/bars° 1.3 Post office 1.1 Dormitory 1.0 Retail'°, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia°. assembly spaces° 1.0 Theater. motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hall34 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries° 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms. elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 Wfft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three- quarter -height partitions (transparent or opaque). and lighting for free- standing display where the lighting moves with the display are exempt. An additional 1.5 wfft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 12856 Southcenter Mall 'Date 3/16/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances fo interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Ceiling Height Watts per ft2 " for this room Ceiling Height limit for this exception" 101 SALES 1.50 12.0 feet 12 feet Adjusted LPA Watts per fe 1.50 103 STOCK ROOM 0.50 12.0 feet 12 feet 0.50 ** From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 2856 Southcenter Mali 'Date 3/16/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Requires Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E_1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a . vertical glazing Indicate vertical glazing on plans n. a. overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w /backup Indicate location E_1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E_1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 'Max. watts 'Indicate watts for each exit sign 1 131 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture type lamps, ballasts, watts per fixture no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 lElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency IM_2 1 TRANSFORMERS (Section 1540) yes I 1540 'Transformers 'Indicate size and efficiency IE_2 1 If "no" is circled for any question, provide explanation: • PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -262 DATE: 07 -11 -08 PROJECT NAME: INDUSTRIAL RIDE SHOP SITE ADDRESS: 2856 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 2 After Permit Issued DEPARTMENTS: BuiCdlfigJisio4 Public Works Fire Prevention Structural n Planning Division Li ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07 -15 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08 -12 -08 Approved Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 PERMIT COORD COPS � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -262 DATE: 06 -13 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 2856 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: D� Build ng Div,sio� Public Works Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 06-1 7-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS RO ING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved U Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07-15-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -262 DATE: 03 -17 -08 PROJECT NAME: WESTFIELD VACANT SPACE SITE ADDRESS: 2856 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: L {)e) Bu ding divis' ion Public Works n Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete o' Comments: Incomplete DUE DATE: 03-20-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-17-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • PROJECT NAME: Viti V� SITE ADDRESS: 0 • PERMIT NO: nN - 2Ce2- ORIGINAL ISSUE DATE: fr,IN REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE MI mg 2 7 -1 l -D K r n / off -7 -) -3-44 wli :),- -or Summ. of Revision: AIILAi , Of 1b i 'f OWA •. ! icev PDtA -yt A.1�1 .._ Received b , ffn / /lrfi REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 2 7 -1 l -D K uNL -7 -) -3-44 wli Summary of Revision: C.,WAftnert Ji T jy - .V Hui da e,'.45 CtLk-v Received by: Weya (AgAlc, (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please nrint) • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: `l / / /oP ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # [� Revision # 2- after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: EG Project Name: Project Address: 2 S > 4c e,,,,% /'1--m // Contact Person: � re. << �c_d�(, u�,. ,L Phone Number: c?/t — 4/-62" b"3 2-- I ha it s>lr, - I' de s% (217 v r,>l y I.Uref; e/? 1 i, k V) Summary of Revision: C her V4.--1-7 , /i & x 4, 7e -�caL„ 74- i -7a t e_ . er---s ei I,' z re- v; re J-4-1--- r( cI / y _,.1 ▪ e n, oi`. --' e h 56exv x• Ye._ /a-7el 1.4 t- PQi c5(2— i /1141-4J nor >lis') GCec,^1-L.." et uS UJcrL / h e I/44,7 x GEC 143e . 6-164-4 115 '4 C)c_e_AA 4- 4,7,4r '- Cec19a--rxe -7 a4_4) . 7`1 CLt'r e d J /fit Sh ..jf- : a27 Ds P" �'xAiras. 64c l � J , 3 4 6 , 4 r Sci 51-"lc-L- 6 ?2„_) RECEIVE , CCTV OF TI.P''. ,', Vic [ccet/7 Sheet Number(s): E -/ "Cloud" or highlight all areas of revision including date of revisi Received at the City of Tukwila Permit Center by: ��Entered in Permits Plus on 1' t 6 `O O lapplicationslforms- applications on line revision submittal Created: 8 -13 -2004 !JUL 112008 PERMIT Ct:. • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: /3 f s/ Plan Check/Permit Number: lC L O ' - 2_ ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Er Revision # ( after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner VI) e6k4'e &/ va,kt ; / /4 fox �5 So Lt M Yom-!' /kilt ( I Project Name: Project Address: CITY OF TTUUKWILA JUN 13 2008 PERMIT CENTER Contact Person: a j- z '-i fide, e-oy,( Phone Number: /P-v, 5 ido 3 do 4d J Summary of Revision: pion ?lei -J &hed -ae5 re -')SPA 1v re /lam Dpi e v; p /4� rcv, sQ fo !)---.cAsr� weir b•(-- Sheet Number(s): — / j "Cloud" or highlight all areas of revision including date of r; vision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on Iha (1/611 \applications\forms- applications on linelrevision submittal Created: 8 -13 -2004 Look Up a Contractor, Election or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full-time supervisory employee. License Information License SMEINS *066DB Licensee Name S M E 1NC OF SEATTLE Licensee Type ELECTRICAL CONTRACTOR UBI 601524252 Ind. Ins. Account Id Business Type CORPORATION Address 1 828 POPLAR PL S Address 2 City SEATTLE County KING State WA Zip 98144 Phone 2063292040 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/2/1994 Expiration Date 3/2/2010 Suspend Date Separation Date Parent Company Previous License Next License PACIFFS973PU Associated License BAKERJT973LR Master Electrician Information License BAKERJT973LR Name BAKER, JON T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MARVICH, STEPHEN E 01/01/1980 PINSKY, ADAM A 01/01/1980 BAKER, JON T AGENT 01 /01 /1980 1 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SMEINS *066DB 05/07/2008 FLOOR PLAN NOTES BY SYMBOL V VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 UNE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROO LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THWN. O NOT USED LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL # DESCRIPTION A COOPER /METALUX 2GA332A120VEBB2 2'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING B UTHONIA gW AZ INCANDESCENT RECESSED DOWNUGHT, 8" 60 WATTS C COOPER / METALUX GA232A120VEB81 1'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL LIGHT LXURWELED LITEFORM COLLECTION EXIT UGHTS/BATTERY BACKUP X2 SUREUTES CC7 EMERGENCY LJGHTING/BULBS INCLUDED 4 HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -277V -WHITE *DS HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY I1SE HUBBEU. ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY B 28 11/13 +10.-D FF REVISIONS No changes shah be as d e t of Tukwila Building Di i NOTE: Revisions will require a n and may include additional pl - e scope 1 of submittal fees. 2856 Southcenter Mall Tukwila, WA 98188 1,3,5 smith cfp. 15 0 PROVIDE AND INSTALL NEW 30 AMP NENA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW VAV. VERIFY LOCATION IN FIELD. O PROVIDE AND INSTALL NEW DISCONNECTjAND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY L CATION IN FIELD. © PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. 0 ,Mechanical d Electrical lumbing t G Piping CItyae NGplVIS1 Wljll_ ®4 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206A64.0700 f ksmith @smithco.org http: / /www.smithco.org/ +10'- Consultant I FILE COPY .: IIVi I J ' H_1 ELECTRICAL /POWER PLAN Pe Nos Is Ito mom and .��ns. i, �d��attthodze any adopted code or Wain= Receipt Copy and =Mons Is acknowledge* Plar reVlew Approval of c the Violation of approved BY Date: • r7! t r • 6294 REGISTERED ARCHETECT Cry of Tukwila 1NC DIVISION Consultant Registration Issues and Revisions No. Date il■i1 ■O.■ NE _ESE + 12' -O" AFF ■■■■■ ■ ■ ■■■ I ■iii ■■1■■■ i ■ ■ ■■ ■i LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL # DESCRIP11ON A COOPER /METALUX 2GA332A120VE882 2x4 LAY -IN FLUORESCENT, T8 ENERGY SAVING B LTHONIA 8 IAZ INCANDESCENT RECESSED DOWNUGHT, 8" 60 WATTS C COOPER /METALUX GA232Al2OVEB81 1'x4' LAY --IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL -LIGHT LXURWELEIJ UTEFORM COLLECTION EXIT UGHTS/6ATTERY BACKUP X2 SURELITES �7 EMERGENCY UGHTING /BULBS INCLUDED HUBBELL c51221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -277V -WHITE HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST 11ME DELAY AND SENSITIVITY 4 r HUR ELL ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SEN5111VITY ELECTRICAL LOAD S v v ARY \EW PANEL 8 Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X 1/20 12 100 EF1 2 1.5 3 3 SPACE – – – X – – – SPACE 4 1.25 3 5 SPACE -- – -- .125 X – -- – SPACE 6 13.8 3 7 SPACE – – – X – – – SPACE 8 -- 3 9 SPACE – -- – X – – – SPACE 10 -- SPACE 11 WATER HEATER 750 12 2120 1250 X – – – SPACE 12 -- X – -- – SPACE 14 800 12 13 750 2 15 SIGN 1200 12 1/20 X – -- – SPACE 16 X – 17 SPACE – -- – REMARKS TOTAL LOAD PHASE 'A' 22280 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61695 WATTS MANUFACTURERS RECOMMENDATION 172 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. X – -- – SPACE 18 19 SPACE – – – X – -- – SPACE 20 21 SPACE – – – X – -- – SPACE 22 23 SPACE – -- -- X – _ SPACE 24 25 SPACE – – – X -- -- – SPACE 26 27 SPACE – – – X 1/20 12 360 GFI RECEPTACLES 28 29 SPACE – – X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE – – – X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE -- -- – X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE -- -- – X 1/20 12 1000 GENERAL RECEPTACLES 36 37 SPACE -- – X 1/20 12 1000 GENERAL RECEPTACLES 38 39 SPACE – -- – X 1/20 12 1000 GENERAL RECEPTACLES 40 41 SPACE -- -- -- X – – -- SPACE 42 REMARKS TOTAL LOAD PHASE 'A' 3560 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 3640 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 3250 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 10450 WATTS MANUFACTURERS RECOMMENDATION 30 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL LOAD S v v ARY 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS \EW PA \ -L H I Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH A B C BKR WIRE WATTS DESCRIPTION CKT LIGHTING 2.8 1.25 3.5 208 1 RECEPTACLES 7.2 1.00 7.2 120 1 WATER HEATER 1.5 1.00 1.5 208 1 MISCELLANEOUS N/A 1.00 N/A 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC .1 1.25 .125 120 1 HVAC 11.0 + 25 OF LARGEST LOAD 13.8 480 3 TOTALS: 23.8 9 27.6 KW = 33 2 AMPS © 120/208 SERVICE – 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK OVERRIDE SWITCHES p. 'b' SIGN LIGHTS (B15) GENERAL LIGHTS (B3) • GENERAL LIGHTS (815) L____J 1 LIGHT SWITCHING DETAIL NOT TO SCALE GENERAL LIGHTS (817) V \EW PA \ -L H I Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM I 1 FMB -1 1000 10 3/20 X 1 /� I l EXISTING ELECTRICAL I I 1/0 20,030 TRANSFORMER 2 NEW PANEL 4 4 1000 X 3/125 19,150 4 3 6 I I 1 L J X 17,165 1000 ■ 5 a 7 SPACE – – – X – – – SPACE 8 4 9 SPACE – -- -- X – -- -- SPACE 10 11 SPACE – – – X – – -- SPACE 12 13 GENERAL LIGHTING 1250 12 1/20 X — -- SPACE 14 15 GENERAL LIGHTING 800 12 1/20 X – – -- SPACE 16 17 GENERAL LIGHTING 300 12 1/20 X – – -- SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 22280 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61695 WATTS MANUFACTURERS RECOMMENDATION 172 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. TIME CLOCK OVERRIDE SWITCHES p. 'b' SIGN LIGHTS (B15) GENERAL LIGHTS (B3) • GENERAL LIGHTS (815) L____J 1 LIGHT SWITCHING DETAIL NOT TO SCALE GENERAL LIGHTS (817) V RISER DIAGRAM GENERAL NOTES P A\ L 1- R tRAV 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 47\MRE E LECTRI CAL 3 WIRE RI 4 ELECTRICAL SERVICE I VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. ® I ,— J® RISER DIAGRAVI NOTES BY SYMBOL O1 PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. PROVIDE AND INSTALL METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS. O PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. 4 PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUIT. O PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'H'. ® PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU -1 ON ROOF. O NOT USED $ PROVIDE AND INSTALL 30 AMP DISCONNECT FOR FMB -1 IN CEILING. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL (1) #4 CU, GROUNDING ELECTRODE CONDUCTOR TO BLDG. STEEL 10 NOT USED 11 PROVIDE AND INSTALL (3) #1/O THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER W / #6 CU GROUND PER NEC 250 -122 1i? PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. 00 PROVIDE AND INSTALL (4) #3/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'A'. 14 PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS REQUIRED @r �/ 1 /� I l EXISTING ELECTRICAL I I © I® I I I NEW PANEL NEW NEW - 14 n V DISTRIBUTION SYSTEM(S) M(S) FOR OTHER TENANTS I I 1 L J EXISTING LANDLORD WIREWAY i ■ a FLOOR LANDLORD TENANT ® PROVIDE AND INSTALL GROUND BUILDING STEEL PER R N.E.C. 250 66 2856 Southcenter Mall Tukwila, WA 98188 smith ca. 318 terry avenue n seethe, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant EWE ° O COMP �C CODE %�QA �o IVE City frukwila SMOG DIVISION RECEIVED CITY OF TUKWILA JUN 13 2008 PERMIT CENTER 6294 Consultant Registration Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 2 03.26.08 3 04.07.08 4 05.29.08 PERMIT BLDG. COMMENTS PERMIT CORR. ISSUE KLS KLS KLS KLS Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description PANELSCHEDULES Computer File CW05- 2008— E2.DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith colic and were created, evolved, and developed for use an and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. E -2 FLOOR PLAN NOTES BY SYMBOL O VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES, • INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 UNE GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THWN. ONOT USED ® PROVIDE AND INSTALL NEW 60 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. O PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL # DESCRIPTION A COOPER /METALUX 2GA332A120VE1382 2'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING B LITHONIA 8W1AZ INCANDESCENT RECESSED DOWNUGHT, 8" 60 WATTS C COOPER/METALUX GA232A120VEB81 1'x4' LAY -IN FLUORESCENT, TB ENERGY SAVING X1 DUAL -LIGHT LXURWELED UTEFORM COLLECTION EXIT UGHTS /BATTERY BACKUP X2 SUREIJTES CC7 EMERGENCY UGHTING/BULBS INCLUDED HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -277V -WHITE F. HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY $per HUBBELL ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY NOTE: 2006 IBC -- Sec. 1006 Provide an average of one foot - candle illumination at the floor along the entire egress pathway and exit discharge APPROVED P'." n >�n r,rr- I�IOATI/1rli ruA.lU p'.77- OI Ift.NGED, MODIFIED OR ALTERED WITHOUT AUTHORIZATION FROM THE BUILDING OreICIAL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS TO FIELD INSPECTIONS 28 fffff /ff/ 'fffffff /fzffff f 2 11/13 La 111 -------- v F//jj ��j%j���jjf /f /jjjjj�iiij /�jj /�j v .• %; % l 0 4 j 0 d :// 77-Z4 15 ////// � // 30 O. PROVIDE AND INSTALL NEW 60 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. O PROVIDE AND INSTALL NEW DISCONNECT:AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. © PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.EC. Ai B ELECTRICAL /POWER PLAN SCALE: 1/4" = 1. -0" 1,2 `1 •••••• ■■■■■■ .■■■■■ • ■ ■EE■■ ■■E■■■ ■■E■■■ s • • -r i FILE COPY permit NO. � s etro Approval review approval is subject not # theoval of cans s of ordina gate: the violation and dons is p1 approved Id Date: J City of Tukw BUILDING DIVISION AFF SEPARATE PERMIT REQUIRED FOR: (Mechanical C0 Electri,* t Plumber 9 [rGas Piping City of Tukwila BiSlILDP,IG DIVISION REVIEWEDFOR CODE COMPLIANCE NFPA 70 - NEC APR 10 1608 City Of Tukwila BUILDING. DIVISION - O/%/////////////%/////////%%%///%%/ z ////i,, A ■■ME■. ■■ ■E■■ ■ ■1•IE■■ H 17 4 ZZ C ■E■■ : -.: ■■f1■■ ■■E■■. ..II.IIIIIIIE. ■■EM• .■E ■■ ■ ■E■, ■ ■if• ■ ■ ■ ■I. ■ ■E■■■ ■■EE■■ Mill= ••••••1 ■ ■E ■ ■ ■z ELECTRICAL /LIGHTING PLAN SCALE: 1/4" = 1' -0" 2856 Southcenter Mall Tukwila, WA 98188 smith c*. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant 6294 REGISTERED ARCHITECT El TATE OF WASHINGTON Consultant Registration T REVISIONS No changes shall be made to the sccopA of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal . and may include additional plan review fees. Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 PERMIT KLS Public Works, Building Division PERIv><i i Uni_E A 08- 6 nCITTLA • frrssi Aw. .r . ofi • TAG rCR�AI'Y e �I %� it 1 Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description POWER /LIGHTING PLAN Computer File CW05- 2008-- E1.DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. FILE t'AC�1l OQ ' E -1 \EW PA \ LW P A\ EL B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X -- -- — SPACE 2 19,150 3 3 SPACE — -- — X -- -- — SPACE 4 1.5 3 5 SPACE — -- -- -- X -- — — SPACE 6 SPACE 3 7 SPACE — -- — X -� — — SPACE 8 SPACE 3 9 SPACE -- — -- X -- — — SPACE 10 SPACE 12 11 WATER HEATER 750 12 2/20 12 X — — — SPACE 12 SPACE 750 X — — — SPACE 14 1/20 X 13 2 15 SIGN 1200 12 1/20 X — — -- SPACE 16 X — — 17 SPACE — — — X -- -- -- SPACE 18 19 SPACE — — — X -- -- -- SPACE 20 21 SPACE — -- — X -- -- -- SPACE 22 23 SPACE — -- — X -- — — SPACE 24 25 SPACE — -- -- X -- -- — SPACE 26 27 SPACE .— -- — X 1/20 12 360 GFI RECEPTACLES 28 29 SPACE — -- — X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE — — -- X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE — — — X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE — — — X 1/20 12 1000 GENERAL RECEPTACLES 36 37 RTU -1 3133 6 3/50 X 1/20 12 1000 GENERAL RECEPTACLES 38 39 3133 X 1/20 12 1000 GENERAL RECEPTACLES 40 X — — — SPACE 42 41 3133 REMARKS TOTAL LOAD PHASE 'A 11,108 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 11,703 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 11,363 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 34,174 WATTS MANUFACTURERS RECOMMENDATION 95 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. \EW PA I \EL H Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 4.8 1 VAV 1 2500 10 3/20 X 1.00 1/0 20,030 TRANSFORMER 2 1.5 19,150 2500 X 3/125 4 4 4 3 2500 1 X 17,165 6 1.5 120 5 SUPPLEMENTAL HVAC 7 SPACE — -- -- X -- — — SPACE 8 TOTALS: 34.1 9 SPACE — -- — X — — — SPACE 10 11 SPACE -- — — X -- — — SPACE 12 13 GENERAL LIGHTING 1250 12 1/20 X -- — — SPACE 14 15 GENERAL LIGHTING 980 12 1/20 X -- — — SPACE 16 17 GENERAL LIGHTING 1345 12 1/20 X — — — SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 25,030 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 24,150 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 22,165 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 71,345 WATTS MANUFACTURERS RECOMMENDATION 86 AMPS 5 .- PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD, SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL LOAD SJVVARY 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK P Fo Fo ono o D • OVERRIDE SWITCHES • • • SIGN LIGHTS (B15) • GENERAL LIGHTS (B3) r L____1 LIGHT SWITCHING DETAIL NOT TO SCALE OFFICE LIGHTS (B5) OFFICE LIGHTS (B7) • RECEPTION LIGHTS (B9) P A\ E L RISER 3 I A G R A V RISER DIAGRAM GENERAL NOTES FLOOR LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH J® 411D ---(_� 14 LIGHTING 4.8 1.25 6.0 120 1 RECEPTACLES 15.8 1.00 12.9 120 1 WATER HEATER 1.5 1.00 1.5 208 1 MISCELLANEOUS N/A 1.00 N/A 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC 1.4 1.25 1.7 120 1 HVAC 9.4 25 OF LARGEST LOAD 11.9 208 3 TOTALS: 34.1 35.5 KW = 98 6 AMPS © 120/208 SERVICE 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK P Fo Fo ono o D • OVERRIDE SWITCHES • • • SIGN LIGHTS (B15) • GENERAL LIGHTS (B3) r L____1 LIGHT SWITCHING DETAIL NOT TO SCALE OFFICE LIGHTS (B5) OFFICE LIGHTS (B7) • RECEPTION LIGHTS (B9) P A\ E L RISER 3 I A G R A V RISER DIAGRAM GENERAL NOTES FLOOR 1 EXISTING CONDITIONS AND PRIOR TO BIDDING AND - -a _ J® 411D ---(_� 14 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 27W EEL 3 PH, 4 WIRE ELECTRICAL SERVICE '2- r ' O ®� 2 VERIFY REQUIREMENTS INSTALLATION. 6 O 1_ RISER DIAGRAv NOTES BY SYMBOL - 0 r I -1 EXISTING ELECTRICAL DISTRIBUTION SYSTEMS) FOR OTHER TENANTS I L _I ® 1 I 1 I TENANT @ PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. O PROVIDE AND INSTALL METER PER LOCAL UTILITY AND LOCAL AUTHORITY RECOMMENDATIONS. O PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. K PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUIT. O PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'H'. � \.::./ PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU -1 ON ROOF. ® PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RTU -2 ON ROOF. `V PROVIDE AND INSTALL 30 AMP DISCONNECT FOR RTU -1 ON ROOF. VERIFY LOCATION IN FIELD. ®9 PROVIDE AND INSTALL 30 AMP DISCONNECT FOR RTU -2 ON ROOF. VERIFY LOCATION IN FIELD. 1O NOT USED 11 PROVIDE AND INSTALL (3) #1/O THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER. 12 • PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. 13 PROVIDE AND INSTALL (3) #3/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'A'. 14 PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS REQUIRED `— f_I_ NEW PANEL NEW PANEL '0' j `�,,�,' EXISTING LANDLORD WIREWAY 0 12 LANDLORD PROVIDE AND INSTALL GROUND TO BUILDING STEEL PER N.E.C. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR 1 0 2008 City 0f Tukwila B ILDING DIVISION 2856 Southcenter Mall Tukwila, WA 98188 smith co. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.64.0700 f ksmith@smithco.org http: / /www.smithco.org/ Consultant 6294 REGISTERED ARCHITECT • KEI 1 STATE OF WASHINGTON Consultant Registration Architect Registration Issues and Revisions No. Date Issues By Check 1 02.08.08 PERMIT KLS RECEIVED CITY OF T' I nnu� MAR 1 1 [008 r -tea ®I� C+ �e-rr ER %vII1 C4:.1'11 =1"s Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use an and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation far any purpose whatsoever without the written perrnission of smith co. 11c. E -2 PART 1 - GENERAL 1.01 SCOPE OF WORK: FURNISH AND INSTALL ALL EQUIPMENT AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENT AND SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND /OR SPECIFIED HEREIN. ALSO ARE INCLUDED ALL OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION INCLUDING ALL ACCESSORIES AND APPURTENANCE REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWING AND SPECIFICATIONS THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. 1.02 REGULATORY REQUIREMENTS CODE COMPLIANCE 15 MANDATORY. NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMITS WORK AND NOT CONFORMING TO THESE CODES. WHERE WORK IS SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (OSH). 2. NFPA #70; NATIONAL ELECTRIC CODE (NEC). 3. NFPA #101: LIFE SAFELY CODE. 4, STATE FIRE MARSHAL. 5. LOCAL UTILITIES COMPANIES. 6. ALL LANDLORD GENERAL REQUIREMENTS FOR MALL. 1.03 LICENSE. FEES AND PERMITS: ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMITS AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. 1.04 SAFETY AND INDEMNITY: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. NO ACT, SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER, THE ENGINEERS OR THEIR CONSULTANTS, IS INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, OR NEAR THE CONSTRUCTION SITE. 1.05 DRAWINGS AND SPECIFICATIONS: ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF THIS DIVISION SHOW ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENTS SHALL BE GOVERNED BY CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS, WHETHER SPECIFICALLY MENTIONED OR NOT. 1.06 CONDITIONS AT SITE: THE ELECTRICAL CONTRACTOR SHALL HAVE EXAMINED THE SITE AND FAMILIARIZED THEMSELVES WITH ALL DISCERNIBLE EXISTING CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS SHALL BE INCLUDED IN THE BID. 1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF WORK. THE CONTRACTOR SHALL BE A LICENSED MASTERED ELECTRICIAN OF THE STATE IN WHICH THE JOB IS LOCATED. 1.08 SHOP DRAWINGS AND MATERIALS LISTS: SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS USTS, AS NOTED BELOW, FOR REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. SUBMITTALS REQUIRED AS FOLLOWS: 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. 2. ENCLOSURES FOR UTILITY COMPANY METERING. 3. MAIN FUSED DISCONNECT SWITCH. 4. PANELBOARDS 5. DISCONNECT SWITCHES 6, LIGHT FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. 1.09 SUBSTITUTIONS: ONE OF MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION IS PERMITTED. NO WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE OWNER. THE OWNER IS THE SOLE JUDGE OF ACCEPTABILITY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM 15 PERMITTED, AND ANY RE- DESIGN EFFORT IS THEREBY NECESSITATED, THE REQUIRED RE- DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.10 COORDINATION: COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH -IN AND CONNECTION FOR EQUIPMENT FURNISHED UNDER OTHER TRADES THAT REQUIRED ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES THAT REQUIRE ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABILITY AND CODE COMPLIANCE. VERIFY EQUIPMENT DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. 1.11 CUTTING AND PATCHING: ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION IS INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND OTHER TRADES IS IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER HOLES, SUPPORTS, ETC. 1.12 ACCEPTANCE DEMONSTRATION: UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR OWNER THE OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. PROPERTY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND /OR TEST TIME SWITCHES PROGRAMMING. 1.13 RECORD DRAWINGS, EQUIPMENT DATA: MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH AS -BUILT INFORMATION AS FEEDER AND SERVICE ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION. DELIVER COMPLETED DRAWINGS TO THE OWNER. DELIVER TO THE OWNER'S REPRESENTATIVE THREE COPIES OF DATA SHEETS OR OTHER CURRENT MANUFACTURERS PUBUCATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT INCLUDING AT LEAST THESE DATA: 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS LIST. 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. 3. USER'S MANUAL AND OPERATING INSTRUCTIONS. 4. MANUFACTURER'S WARRANTY. 1.14 CLEANUP RID THE PREMISES OF SCRAP MATERIALS, TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. 1.15 GUARANTEE: GUARANTEE THE INSTALLATION FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHANGE. 1.16 TEMPORARY SERVICES: PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE PREMISES FOR BENEFICIAL OCCUPANCY. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: 1. THREE 20 -AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE GFI TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA REQUIREMENTS. 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARALLEL TO THE DEMISING WALLS, WITH ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN ROWS TO SIXTEEN FEET OR LESS. 3. FLOOD LIGHTING AND TASK LIGHTING FOR PAINTING AND OTHER FINISH WORK. WHEN PERMANENT ELECTRICAL SERVICE IS OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT USED FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR REMOVAL OF TEMPORARY SERVICE PROVISIONS. 1.17 OWNER- FURNISHED ITEMS: CONTRACTOR SHALL INSTALL, CONNECT AND COMPLETE THE FOLLOWING ITEMS FURNISHED BY THE OWNER AND SHALL PROVIDE WIRES, CABLES, CONNECTORS, PIGTAILS, CORDS AND CORD -CAPS, BOXES, CONDUIT, PLATES, SUPPORTS, AND. OPERATING TESTS TO MAKE COMPONENTS AND SYSTEMS OPERATE SATISFACTORILY. PROVIDE SYSTEMS DRAWING FROM THE MANUFACTURER THROUGH THE OWNER IN ORDER TO INSTALL COMPLETE OPERABLE SYSTEM. 1. MUSIC SOUND SYSTEM COMPONENTS. 2. ENTRY ALARM SYSTEM CONTROL PANEL AND CONTACTS /SECURITY SYSTEMS. PART 2 - PRODUCTS 2.01 MATERIAL APPROVAL ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITERS LABORATORIES LABEL. MATERIALS THAT ARE NOT COVERED BY UL TESTING STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AFTER INSTALLATION. 2.02 CONDUITS AND OTHER RACEWAYS: A. RIGID STEEL: HOT- DIPPED GALVANIZED. B. INTERMEDIATE METAL CONDUIT (IMC): HOT- DIPPED GALVANIZED C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO- GALVANIZED. 0, WIREWAY CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND OUTDOORS. 2.03 WIRES AND CABLES: A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: 1. CONDUCTOR: MINIMUM SIZE #12 . A. #12 AND #10 AWG SOLID COPPER. B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. 2. INSULATION TYPE: A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THWN FOR DRY LOCATIONS. 8. #10 THROUGH #4/0 AWG: XHHW (55 MILS). C. #250 MCM AND LARGER XHHW (65 MILS). D. GROUNDING WIRE: TW. B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #16 AWG MINIMUM, WITH THWN INSULATION FOR UNDERGROUND OR WET LOCATIONS AND T1-11-IN INSULATION FOR DRY LOCATIONS. C. ACCEPTABLE PRODUCTS GENERAL ELECTRIC, ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING APPLICABLE IPCEA STANDARDS. 2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: A. OUTLET BOXES: 4" SQUARE X 1 - 1/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO -TYPE WITH PLASTER RING AND COVER FOR GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). B. JUNCTION BOXES SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE- GAUGE STEEL IN LARGER SIZES WITH SURFACE OR FLUSH -TYPE SCREW - MOUNTED TRIM COVERS, BOTH BOXES AND COVERS INHIBITOR- PRIMED AND PAINTED INSIDE OUT. C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN 4- 11/16" SQUARE X 2 -1/8" DEEP WITH SINGLE -GANG RING AND SIERRA #S -754N SPLIT PLATE BUSHING. E. ALL BOXES AND ASSOCIATED COMPONENTS SHALL BE STEEL CITY 683 SERIES, WITH P60 -3B COVERPLATE. 2,05 WIRING DEVICES AND PLATES: WIRING DEVICES AND PLATES SHALL BE HUBBELL. ARROW HART, GE OR P &S WITH HUBBELL NUMBERS USED TO SPECIFY TYPE USED. STANDARD DESIGN: A. SWITCH AND RECEPTACLES DEVICES SHALL BE IVORY EXCEPT WHEN THE DEVICE IS LOCATED ORE A PURPLE WALL, WHEN ON PURPLE WAIL DEVICE SHALL BE BLACK B. ISOLATED GROUND RECEPTACLES SHALL BE WHITE WITH ORANGE TRIANGLE AS REQUIRED PER NEC, MANUFACTURED BY LEVITON # 5362 -IGW OR APPROVED EQUAL C. SWITCHES SHALL BE 20 AMP, 120/277 VOLT A.C. RATED SINGLE POLE SWITCHES SHALL BE #1221 AND 3 -WAY SWITCHES SHALL BE #1223. D. RECEPTACLES SHALL BE GROUNDING TYPE #5362. 2.06 CONDUIT HANGERS: FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR POWERSTRUT. FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM DEFLECTION NOT GREATER THAN 1/8" 2.07 WIRE CONNECTORS: FOR WIRE SIZES #8 AWG AND SMALLER INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C. 600V, FOR BUILDING WIRING AND 100DW IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL. FOR WIRE SIZE #6 AWG AND LARGER T & B OR EQUIVALENT COMPRESSION TYPE WITH 3M #33 OR PLYMOUTH "SLIPKNOT GRAY" TAPE INSULATION. 2.08 PANELBOARD: A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL BE OF COLD - ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20 ". FINISH EXPOSED PART \MTH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GRAY ENAMEL SUITABLE FOR OVER PAINTING IN FIELD IT DESIRED. B. BUS BARS: PROVIDE GROUND BLOCK WITH FULL COMPLEMENT OF TERMINALS IN ADDITION TO INSULATED NEUTRAL BUS. FUTURE BREAKER SPACES SHALL HAVE COMPLETE PROVISION INCLUDING BUSSES AIR CONNECTING HARDWARE. C. MANUFACTURER PANELBOARD SHALL IN GENERAL ELECTRIC TYPE AQ OR TYPE AE OR EQUIVALENT PRODUCTS OF CUTTER- HAMMER, SQUARE D, OR SIEMENS -ITE. D. CIRCUIT BREAKERS SHALL BE BOLT -ON, THERMAL - MAGNETIC, MOLDED CASE TYPE: U.L. LISTED FOR SWITCHING DUTY. BREAKERS SHALL HAVE ON OVER - CENTER TRIP FREE, TOGGLE TYPE HANDLE WITH QUICK -MAKE, QUICK -BREAK ACTION. 1. 120/208 VOLT PANELS: SHALL BE GENERAL ELECTRIC TYPE "Q" UNE, BOLT -ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING CAPACITY AS SHOWN. NO SERIES RATING ALLOWED. 2. PROVIDE MULTI -POLE UNITS WITH COMMON TRIP ELEMENT. 3. CIRCUIT BREAKERS USED ON "ON -OFF" CONTROL OF FLUORESCENT LIGHTING (PANELBOARD SWITCHING) SHALL BE UNDERWRITERS - LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABILITY. E. IDENTIFICATION: PROVIDE SCREWED -ON (NO ADHESIVES) BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION AN OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE, AND PHASE IN MINIMUM 1/4" HIGH LETTERS. EACH PANEL SHALL CONTAIN A METAL- FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. F, COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. 2.09 DRY TYPE TRANSFORMER: A. GENERAL: EQUIPMENT SHALL CONFORM TO OR EXCEED REQUIREMENTS OF NEMA, ANSI STANDARD C89.2 FOR DRY TYPE TRANSFORMERS FOR GENERAL APPLICATIONS. ACCEPTABLE PRODUCTS ARE THOSE OF GENERAL ELECTRIC COMPANYS "QHT" UNE OR EQUIVALENT SQUARE D, SIEMENS -ITE, OR CUTTLER- HAMMER. ELECTRICAL RATINGS: 1. PRIMARY WINDINGS VOLTAGE 480 VOLTS, 3- PHASE, DELTA. SECONDARY WINDING VOLTAGES 208Y/120 VOLTS, 3 -PHASE GROUNDED. FREQUENCY: 60 HZ. KVA RATING: AS SHOWN ON DRAWINGS. TOPS: SIX (6) 2.5% FULL CAPACITY TAPS, 2 ABOVE AND 4 BELOW, RATED VOLTAGE. IMPEDANCE: FOR TRANSFORMERS LARGER THAN 75 KVA, 4.5% MINIMUM, 5.75 MAXIMUM 2. WINDING TEMPERATURE RISE SHALL BE 150 DEGREES CENTIGRADE IN ACCORDANCE WITH UL SPECIFICATION ARTICLE 506. 3. TRANSFORMER SHALL BE CAPABLE OF OPERATING AT 100% OF NAMEPLATE RATING CONTINUOUSLY WHILE IN AN AMBIENT TEMPERATURE NOT EXCEEDING 40 DEGREES CENTIGRADE. 4. TRANSFORMER SHALL MEET THE DAILY OVERLOAD REQUIREMENTS OF ANSI STANDARD C57.96. C. VIBRATION ISOLATION, FACTORY- INSTALLED: PROVIDE NEOPRENE RUBBER PADS TO ISOLATE CORE AND COIL ASSEMBLY FROM TRANSFORMER ENCLOSURE. D. INSTALLATION: 1. ANCHOR TRANSFORMER SECURITY WITH MINIMUM 1/2" DIAMETER BOLTS. STRENGTH OF BOLTS USED TO SECURE THE TRANSFORMER SHALL BE SUFFICIENT TO RESIST SHEAR AND UPLIFT PRODUCED BY FORCE EQUAL TO 1/2 OF THE EQUIPMENT MASS APPLIED HORIZONTALLY AT ENTER OF GRAVITY, 2. PROVIDE 1 THICK HIGH RESIUENCY PADS TO ISOLATE TRANSFORMER FROM FLOOR OR PLATFORM. KORFUND "ELASTO RIB" OR EQUIVALENT. 3. USE FLEXIBLE CONDUITS AT LEAST 24" LONG FOR ELECTRICAL CONNECTIONS. 4. PROVIDE GROUNDING OF EACH TRANSFORMER SECONDARY INCLUDING ALL CONDUITS. WIRES, AND CONNECTORS IN ACCORDANCE WITH NEC 250 -26 AND ANY LOCAL ADDITIONAL REGULATIONS. 2.10 INDIVIDUALLY MOUNTED MOTOR CONTROLLER: A. FOR POLYPHASE MOTORS: COMBINATION MOTOR CIRCUIT PROTECTOR AND MAGNETIC STARTER, WITH 3 -LEG OVERLOAD PROTECTION. PROVIDE TWO INTERLOCK CONTACTS OF THE INTERCHANGEABLE OPEN -CLOSE TYPE. PROVIDE HAND -OFF AUTOMATIC SELECTOR SWITCH, MOTOR RUNNING PILOT LIGHT AND RESET BUTTON IN COVER. CIRCUITS 300V AND OVER SHALL BE PROVIDED WITH INDIVIDUAL 120V CONTROL TRANSFORMERS. B. STARTERS FOR FRACTIONAL HORSEPOWER 120V MOTORS SHALL BE MANUAL TYPE UNLESS SHOWN OTHERWISE, EQUIPPED WITH BUILT -IN OVERLOAD PROTECTION. C. ACCEPTABLE MANUFACTURERS GENERAL ELECTRIC SIEMENS, SQUARE D, CUTTER- HAMMER, AND ALLEN BRADLEY. 2.11 LIGHTING A. LIGHTING TO BE PROVIDED BY OWNER. SUBCONTRACTORS TO INSTALL ALL FIXTURES COMPLETE, INCLUDING LAMPS AND BALLASTS, READY FOR SERVICE. B. SUPPORTS: PROPER SUPPORTS AND MOUNTING ACCESSORIES, SUCH AS HANGERS, STEMS, YOKES, PLASTER FRAMES, ETC SHALL BE PROVIDED AS REQUIRED BY THE TYPE OF CEILING INSTALLED. WHERE SWIVEL CANOPIES OR BALL ALIGNERS ARE SPECIFIED, THEY SHALL CAUSE FIXTURE TO HANG PLUMP REGARDLESS OF CEIUNG SLOPE. C. FIXTURE DESIGNATION: FIXTURE TYPES ARE DESIGNATED ON DRAWINGS, WHERE ONLY ONE FIXTURE DESIGNATION IS SHOWN, IT APPLIES TO ALL FIXTURES IN THAT ROOM OR AREA. FOR EXACT FIXTURE COUNT AND LOCATION REFER TO REFLECTED CEILING PLAN. D. WIRE 1 -LAMP AND 3 -LAMP FLUORESCENT FIXTURES IN TANDEM WHERE REQUIRED BY CODE. E. BALLASTS: ADVANCE, GE, OR APPROVED HIGH FREQUENCY ELECTRONIC, FULL LIGHT OUTPUT, ENERGY SAVING, CLASS "P ", HIGH POWER FACTOR. ETL CERTIFIED, SOUND RATING "A" OR AS INDICATED ON DRAWINGS. 2.12 MISCELLANEOUS MATERIALS: A: SAFETY SWITCHES: HEAVY DUTY TYPE, 600V, HORSEPOWER RATED FOR MOTORS, FUSED OR NON -FUSED AS REQUIRED. MOUNT IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR CUTLER - HAMMER. PART 3 - EXECUTION 3.01 GENERAL A. ELECTRIC SYSTEM LAYOUTS INDICATED ON THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. GOVERN EXACT ROUTING OF CABLE AND WIRING AND THE LOCATIONS OF OUTLETS BY THE STRUCTURE AND EQUIPMENT SERVED. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS. B. CONSULT ALL OTHER DRAWINGS, VERIFY SCALES AND REPORT ANY DIMENSIONS, DISCREPANCIES OR OTHER CONFLICTS WITH OWNER BEFORE SUBMITTING BID. C. ALL HOME RUNS TO PANELBOARDS ARE INDICATED AS STARTING FROM THE OUTLET NEAREST THE PANEL AND CONTINUING IN THE GENERAL DIRECTION OF THAT PANEL. CONTINUE SUCH CIRCUITS TO THE PANEL AS THOUGH THE ROUTES WERE COMPLETELY INDICATED. TERMINATE HOMERUNS OF SIGNAL, ALARM, AND COMMUNICATION SYSTEMS IN A SIMILAR MANNER. D. AVOID CUTTING AND BORING HOLES THROUGH STRUCTURE OR STRUCTURAL MEMBERS WHEREVER POSSIBLE. OBTAIN PRIOR APPROVAL OF OWNER AND CONFORM TO ALL STRUCTURAL REQUIREMENTS WHEN CUTTING OR BORING THE STRUCTURE IS NECESSARY AND PERMITTED. E. FURNISH AND INSTALL ALL NECESSARY HARDWARE, HANGERS, BLOCKING, BRACKETS, BRACING, RUNNERS, ETC. REQUIRED FOR EQUIPMENT SPECIFIED UNDER THIS SECTION. F. PROVIDE NECESSARY BACKING REQUIRED TO INSURE RIGID MOUNTING OF OUTLET BOXES. 3.02 WIRING METHODS: A. NO 'ROMEX' OR 'BX' WIRING IS PERMITTED - ALL ELECTRICAL WIRING MUST BE IN CONDUIT. B. CONDUIT SHALL BE RIGID STEEL, IMC OR EMT AS FOLLOWS: 1. ABOVE GROUND: USE RIGID STEEL IMC OR EMT. A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. B. LOCATIONS SUBJECT TO MECHANICAL INJURY: RIGID STEEL OR IMC ONLY. C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMC OR RIGID STEEL CONDUIT 2. UNDERGROUND: USE RIGID STEEL. C. USE FLEXIBLE CONDUITS IN THE FOLLOWING APPLICATIONS. 1. RECESSED LIGHTING FIXTURES. 2. MOTOR CONNECTIONS. 3. AT BUILDING JOINTS AND WET LOCATIONS, FLEXIBLE CONDUIT SHALL BE LIQUID TIGHT TYPE. D. LIGHT FIXTURES INSTALLED IN SHEETROCK CEILINGS MAY BE WIRED FROM FIXTURE TO FUTURE USING METAL CLAD (MC) CABLE. VERIFY THAT LIGHT FIXTURES ARE PROVIDED WITH JUNCTION BOXES APPROVED FOR THIS PURPOSE. MC TYPE CABLE TO MEET ANSI /NFPA 70 REQUIREMENTS. CABLE ARMOR TO BE INTERLOCKED STEEL METAL TAPE. MC TYPE CABLE MANUFACTURED BY AFC CABLE SYSTEMS, PIRELLI CABLE CORPORATION AND SOUTHWIRE COMPANY ARE APPROVED. MC CABLE SHALL NOT BE USED TO WIRE LIGHT FIXTURES INSTALLED IN LAY -IN OR EXPOSED CEILINGS, OR TO WIRE RECEPTACLES. 3.03 INSTALLATION OF CONDUITS: GENERAL: 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENTER LINES OF COLUMNS END BEAMS. 3. CONDUITS ABOVE CEILINGS SHOULD NOT OBSTRUCT REMOVAL OF CEILING TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED WITH MECHANICAL WORK TO AVOID ANY CONFLICT. B. CONDUIT SUPPORTS: 1. SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURE AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY CONDUIT TO MECHANICAL DUCTS OR PIPES. 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING SUPPORT WIRES WITH CADDY CLIPS ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT I5 PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG SUCH CONDUIT SO AS NOT TO AFFECT LEVEL OF CEILING. 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT IS NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURE. C. CONDUIT PENETRATION: 1. PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING. SEAL PENETRATION WITH FIRE RETARDANT SEALANT SPECIFIED HEREIN. 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF OR EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS DETAILED ON THE DRAWINGS. 4. PENETRATING NON -FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED. PENETRATIONS MUST BE SEALED WITH PLASTER PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH IS APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH ESCUTCHEONS, ONE ON EACH SIDE OF WALL. 5. PENETRATING SUSPENDED CEILING: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION, PROVIDE ESCUTCHEON FOR EACH CONDUIT BELOW CEILING. 3.04 CONNECTIONS TO EQUIPMENT: A. GENERAL 1. FURNISH AND INSTALL REQUIRED POWER SUPPLY CONDUIT AND WIRING TO ALL EQUIPMENT. SEE BELOW FOR OTHER WIRING REQUIRED. 2. FURNISH AND INSTALL A DISCONNECT SWTCH IMMEDIATELY AHEAD OF AND ADJACENT TO EACH MAGNETIC MOTOR STARTER OR APPLIANCE UNLESS THE MOTOR APPLIANCE IS LOCATED ADJACENT AND WITHIN SIGHT OF THE SERVING PANELBOARD, CIRCUIT BREAKER OR SWITCH. VERIFY ALL EQUIPMENT NAMEPLATE CURRENT RATINGS PRIOR TO INSTALLATION. 3. INSTALL ALL ROUGH -N WORK FOR EQUIPMENT FROM APPROVED SHOP DRAWINGS TO SUIT THE SPECIFIC REQUIREMENTS OF THE EQUIPMENT. 4. FURNISH AND INSTALL MANUAL THERMAL PROTECTION FOR ALL MOTORS NOT INTEGRALLY EQUIPPED WITH THERMAL PROTECTION. 5. FURNISH 120 VOLT POWER TO EACH CONTROL PANEL AND TIME SWITCH REQUIRING A SOURCE OF POWER TO OPERATE. 3.05 INSULATION OF WIRES: A. PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS BEEN COMPLETED. B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL. SPLICES IN CABLES WHERE REQUIRED SHALL BE MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES. MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8" OF CORRECTLY COLOR -CODED TAILS LEFT IN THE BOX. C. SPLICES IN WIRES AND CABLES SHALL BE MADE UTILIZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. D. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS TO RECEPTACLE AND WIRING DEVICE TERMINALS AS RECOMMENDED BY MANUFACTURER. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE IS NOT APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. E. PROVIDE BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD. 3.06 WIRE COLOR CODE: COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12 THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF ANY SIZE IN CABLE ASSEMBUES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND 120/208V BLACK RED BLUE WHITE GREEN 277/480V BROWN ORANGE YELLOW GRAY GREEN 3.07 IDENTIFICATION A. PROVIDE NAMEPLATES FAR SWITCHGEARS, PANELBOARD, AND ALL SIMILAR DEVICES. NAMEPLATES SHALL BE SCREWED (NO ADHESIVES) ENGRAVED BAKEUTE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION SHOWING PANEL DESIGNATORS, VOLTAGE AND PHASE IN MINIMUM 1/4" HIGH LETTERS. B. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND CIRCUIT NUMBER TO WHICH THE DEVICE IS CONNECTED. C. EACH BOARD SHALL CONTAIN A METAL - FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. D. PANELBOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANELBOARD SCHEDULES FOR ALL PANELBOARD. 3.08 GROUNDING A. ELECTRICAL SERVICE AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEMS SHALL BE GROUNDED IS ACCORDANCE WITH NEC ARTICLE 250 -3 TO 250 -26, INCLUSIVE. B. GROUND NON- CURRENT CARRYING METAL PORTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR CABLE TRAYS TO PROVIDE A LOW IMPEDANCE PATH FOR UNE --TO- GROUND FAULT CURRENT AND TO BOND ALL NON- CURRENT CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250 -95 UNLESS LARGER CONDUCTORS ARE SHOWN ON DRAWINGS. C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION. WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER SIZES, BLOCK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVICE ENCLOSURE. END OF SECTION COMPLIANCE CEDE DE NFPA 70 - NEC APR 1 u 23(18 City a Tukwila B . ILDIN DIVISION.: 2856 Southcenter Mall Tukwila, WA 98188 smith c*. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant 6294 Consultant Registration Issues and Revisions Architect Registration No. Date Issues By Check 1 02.08.08 PERMIT KLS CI-FY F Ti U(ML PERMIT I ER Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description ELECTRICAL SPECIFICATIONS Computer File CW05- 2008- -E3,DWG Scale AS NOTED Template 4.3 (12 0101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use an and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. E -3