Loading...
HomeMy WebLinkAboutPermit EL08-0294 - AT&T MOBILITYAT &T MOBILITY 16425 SOUTHCENTER PY ELO8-294 Citybf Tukwila e Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 5379200290 Address: 16425 SOUTHCENTER PY TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -294 Issue Date: 08/13/2008 Permit Expires On: 12/20/2008 Tenant: Name: AT &T MOBILITY Address: 16425 SOUTHCENTER PY , TUKWILA WA Owner: Name: ARGUS GROUP LTD Phone: Address: C/O METROVATION , 225 108TH AVE NE #520 Contact Person: Name: SAMSON HU Phone: 714- 327 -4203 Address: 4 HUTTON CENTER DR, SUITE 800 , SANTA ANA CA Contractor: Name: VALLEY PLUMBING /ELECTRIC INC Phone: 360 988 -9631 Address: PO BOX 65 , SUMAS WA Contractor License No: VALLEPI141LJ Expiration Date: 10/31/2009 DESCRIPTION OF WORK: RELOCATE EXISTING LIGHTING FIXTURES AND SERVICE PANEL. Value of Electrical: $15,000.00 Fees Collected: $386.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature. Date: d s j I hereby certify that I have read an ex. ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be oomph • wit whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pejformance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Ja'SO" Date: e /O$ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -294 Printed: 08 -13 -2008 Parcel No.: 5379200290 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 16425 SOUTHCENTER PY TUKW AT &T MOBILITY PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -294 ISSUED 03/21/2008 08/13/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be m accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. doc: Cond -Eiec EL08 -294 Printed: 08-13 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. E L.09- ro-o'L Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION '' "-- King Co Assessor's Tax No.: 53 -7' C)-f% - QL)C( 0 Site Address: 1 (/ ?Q-2.S ,r4-a-1 l ` adi Suite Number: Floor: Tenant Name: AT g T • New Tenant: ❑ • Yes ❑ ..No Property Owners Name: '/ 5z1 4 / ' i U T' S. Mailing Address: 1 1 Zd red 4r-4,1 ► ef. i/l Al Ar City G (#4 State lb-'of ) CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: 7M// elN) NIA l . 11 Day Telephone: /�4 �Z7 4? 6?? Mailing Address: r4 ,4 ,4 J24 ' i Tt /l� GEti e itz).0 4741471 ?A)4 LA .12747 City State Zip E -Mail Address: Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: �Y2 Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone: Fax Number: State Valuation of Project (contractor's bid price): $ 1,t Scope of Work (please provide detailed information): * JLA TV /141 i4t LT:AMl■r4 flatco . Will service be altered? ❑ Yes No Adding more than 50 amps? ❑ Yes el No Type of Use: Type of work: / ❑ New ❑ Addition ❑ Service Change Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Pro .e•_, Puget Sound Energy Seattle City Light H:.Applicattons\Forms- Applications On Line \4.2007 - Electrical Permit Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ....$140.00 (including an anached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits.. . . $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - IDate Application Accepted: Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Date: -.Day Telephone: 6 41 4? G Zip / e8 City Statc Date Application Expires: Staff Initials: H, Applicanons\Forms- Apphcanons On Line14•2007 • Etectncal Permit Application doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -02921 Initials: BLH User ID: ADMIN Payee: VALLEY PLUMBING & ELECTRIC Payment Date: 08/13/2008 Total Payment: 550.00 SET ID: 0813 SET NAME: AT &T MOBILITY SET TRAMACTIONS: Set Member Amount (EI:0:82'941 386.00 EL08 -730 164.00 TOTAL: 550.00 TRANSACTION LIST: Type Method Description Amount Payment Check 19803 550.00 TOTAL: 550.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 550.00 TOTAL: 550.00 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 13(- £Log- 211 PERMIT NO. (206)431 -367 Project: 4T4- T tiogtt4 Type of Inspection: glop \ Address: I(P1 z� SCILr�. PY. Date Called: �-. Special I structions: Date Wanted: /D /21 art, p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: (AtikctkonotJ5 a+)E - D.K. gmht-t Inspector: Date: 0/10� El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .as•.. :4. ..aCl..s.• el6u.. - a:• .. : �:ms�i ,x. ys.,.re .+Jd}ll INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION INSPECTION RECORD Retain a copy with permit 6300 Southcenter Blvd., #100, Tukwila, WA 98188 AL, 0 ?_41/ PERMIT NO. (206)431 -3670 Project: AT T 00biLly1 Type of Inspection: . /O J Address: 1(012' . C1is ill• Date Called: ijo rt S : I) 6(C! r c Eft c.A.,E k/.11-0,J S `lc of wicerC1\ u 1J b a 1/\, j Special Instructions: 30 C tit, t1 -J(-) Ok(NOLIC Li 5Et5 Ca )'t9 Date Wanted: loh`I P.m. Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: f7A 0.1K. TD accOP y (K(L.614, &fTLI net) ) ijo rt S : I) 6(C! r c Eft c.A.,E k/.11-0,J S `lc of wicerC1\ u 1J b a 1/\, j 2) I3D41). Keof.rsr 1 4,ca►,JrJ(LT' 64cu5IQ 30 C tit, t1 -J(-) Ok(NOLIC Li 5Et5 Ca )'t9 w, KoofToi) 041T5 IN¶)twrirJc\ ?mitt AA Ali) 1 or ki i4A7J1(ALLy 4- racmc9.) Sri 6a.tAlaK aerr,iDL ( Loc4 Fog. F/A Ctecoir s) RELoca Kon1Tor Afr 17t5(DniNifcr Inspector: OcivAicr Date: 1 O J/ Og El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: Type of Inspection: 7003 Address: i 61 5114 CA ' Ri - Date Called: Special Instructions: Date Wanted: ii ���J� 69' Requester: Phone No: cgtApproved per applicable codes. Corrections required prior to approval. COMMENTS: c 6ILs 'JZ ( Q►/ Inspector: I5NAk EJ$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: /0/111/0g Receipt No.: IDate: INSPECTION RECORD E L ,L Retain a copy with permit 4r INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (I- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: �� �` 1r Ill Type of Inspection: �QA � 3 Address: tt, t 2-5 5mer• (• Date Called: �- Special Instructions: Date Wanted: to i a:m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - 3 UM tf it V NM1 x11)1 (+. roe- Kb/4060T, - i lLAAJ4 wIU (oAIpdfr"- 5 )Poe 5 70 iv Tn6D 70 sr1UcT)f A-7.)p (Alp — /0 Pt. &C- w / c Ovir SJPPor'_O Inspector: Date: ! CYD4 l0 ❑ $60.00 REINSPECTION FEE R UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1. r• A,. w.6 . _ r.w• a ...- ti-w...- INSPECTION RECORD Retain a copy with permit x`'03- Z(� CITY OF TUKWILA BUILDING DIVISION PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36(70 Project: A u EI t1461 Lt Type of Inspection: 7003 3 \, Address: /405 51140-1c PY • Date Called: Special Instructions: Date Wanted: (0 3 (a.iy m. Requester: Phone No: EJApproved per applicable codes. Il Corrections required prior to approval. COMMENTS: FA 9A/. - elm/Nc7n¢.5Aq- 5►tWcl Inspector: _1;,-/ &xis Date: 13 /z to inspect on fee must El $60.00 REINSPECTION FEE REQUIRED. Prior p be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPE ION NO. INSPECTION RECORD Retain a copy with permit :L4- 21 PERMIT NO. (206)431 -3670 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 Project: Arrirr. A Type of Inspection: N. `yQO� Addr /s ;: , 2 S 5 fk Date Called: Special Instructions: Date Wanted: ` a. � m. Requester: Phone No: RApproved per applicable codes. Ij Corrections required prior to approval. COMMENTS: OX. 56E,A0E poufJp14141 Inspector: Date: 01 t.. $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISI 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit gLo'211f PERMIT NO. ON (206)431 -370 Project: AT -1-- - B /1,1 r7 Type of Inspection: ?ooi v Address: ,4112-s 9401k PY. Date Called: Special Instructions: Date Wanted: /D� l/ a.m. p.m Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Pe .9. . tA) ()No / istArg9 L-125 Inspector: Date: oVor t El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: lDate: INSPECTION RECORD eta- Zq 1/ \c Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 9 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Arco-- t' � V V �u�y Type of Inspection: 00 Address: 1 175- s-ycrt. N - Date Called: Special Instructions: Date Wanted: 1� a.m. + p.m. Requester: jjjj �` Phone No: Approved per applicable codes. Ij Corrections required prior to approval. COMMENTS: .K. � J49 RSLA(3 Cacc"IN tr5 4/0 F76)16, Inspector: Date: Os? 24 /0 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: wa+a. .r n 4661.2.64' 1drlimaam° a.�rr�sre..x INSPECTION RECORD ���� Z� Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION F 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3B 0 Project: T"006i Art r V f Type of Inspection: 7oo/ Address: ��� in 1 . Date Called: r Special Instructions: Date Wanted: -Q CT.m. O �d Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval.3 COMMENTS: Ric O.K. - SGTLdut Aff9 1.416(44---) Inspector: %1,1 &if*, El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: DgZo a4 Receipt No.: 'Date: .-.1.-- ....C.Ar • ,. �x INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit (L6 2111 PERMIT NO. (206)431 -3680 Project: • Type of Inspection: �� ` Address: Roil zcSic..Py Date Called: r---, Special I structions: �c�P- � 4lCt Date Wanted: St?! lit a.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: . 1611> Sf(Jic�- Inspector: -11.64/Je-,\ r n$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 07 -29 -2008 City of f Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SAMSON HU 4 HUTTON CENTER DR, SUITE 800 SANTA ANA CA 912707 RE: Permit Application No. EL08 -294 16425 SOUTHCENTER PY TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 03/21/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 09/17/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 09/17/2008. If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, J P xc: r Marshall t Technician Permit File No. EL08 -294 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 PERMIT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -294 DATE: 07 -18 -08 PROJECT NAME: AT &T MOBILITY SITE ADDRESS: 16425 SOUTHCENTER PY Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: B�j 1-"A udDi ion Public Works n Fire Prevention Structural Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 07-22-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUT NG: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-19-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PROJECT NAME: SITE ADDRESS: • PERMIT NO: 49C Qv) ORIGINAL ISSUE DATE: 1-0- • REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS 1 o-1«ir Aftr't _ Summary of Revision: L('QOik 611../ y∎ 4 ,l v' l Aw awpi r Received by: REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: - Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila at Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7,4 og- Plan Check/Permit Number: - z14. Response to Incomplete Letter # Response to Corre ti s LLetter # Revision # Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: AT I 1(4 i ct(k top-( GA,A407.1 414(4 Phone Number: `7/4 277 4252, env OF ru U! JUL 18 2008 PERMIT CENTER Summary of Revision: voi1V1 ev:474 tir4F £ WIC 4 th Sheet Number(s): f% d - 14 1 - 102 1 E - 1 n ?� "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: J 7i/V Entered in Permits Plus on n4(10 \applications\forms- applications on Iine\revision submittal Created: 8 -13 -2004 Revised: Untitled Page Electrical Contractor • 0 Page 1 of 2 A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. VALLEY PLUMBING /ELECTRIC INC Business and Licensing Information Name VALLEY PLUMBING /ELECTRIC INC Phone 3609889631 Address 910 W FRONT ST Suite /Apt. City State Zip County Business Type Parent Company SUMAS WA 98295 WHATCOM CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 600540228 ACTIVE VALLEPI141 LJ ELECTRICAL CONTRACTOR 6/11/1986 10/31/2009 VANDEB`980R0 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License VANDEB`980R0 Name VANDERVEEN, BUTCH Status ACTIVE ■ Business Owner Information Name Role Effective Date Expiration Date BOS, JERALD A 01/01/1980 VANDER VEEN, BUTCH 01/01/1980 BOS, KATHY 01/01/1980 BODE, KEITH A AGENT 01/01/1980 https: // fortress .wa.gov /lni/bbip/Detail.aspx ?License= VALLEPI141 LJ 08/13/2008 Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK Revised July 2007 2006 Washington State Nonresidential Energy Code Compliance Forms cc a 0) 0 cV co N 0 W 0) U 0 C 0 N N a 0 yc0 t l0 C U 0 O cr - • '• tin• Summa LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 PROJECT Project Address at &t - TUKWILA Date 7/16/2008 INFORMATION 16425 SOUTHCENTER PKWY For Building Department Use TUKWILA, WA Applicant Name JACOBS CARTER BURGESS Applicant Address 4 HUTTON CENTER DRIVE, SUITE 800 SANTA ANA, CA 92707 Applicant Phone (714) 327 -1600 RETAIL - DISPLAY (per 15 -1, footnote 10)** 1.50 Project Description 0 New Building 0 Addition • Alteration • Plans Included Refer to WS EC Section 1513 for controls and commissioning requirements. 002, 003, 004 Compliance Option 0 Prescriptive • Lighting Power Allowance 0 Systems Analysis LPA spaces are indicated on plans 588.0 Alteration Exceptions (check appropriate box - sec. 1132.3) being to the lighting • No changes are made Less than 60% of the fixtures new, installed wattage not C increased & space use not changed Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 Area in ft2 Allowed x Area 001 RETAIL 1.50 3878.0 5817.0 001 RETAIL - DISPLAY (per 15 -1, footnote 10)** 1.50 420.0 630.0 002, 003, 004 OFFICE 1.00 588.0 588.0 005A, 005B TOILET 0.80 132.0 105.6 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 7140.6 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 001 "A" - 4' Fluor. w/ (2) 48" T8 32W lamps, elec. ballast 48 65.0 3120.0 001 "B" - 4' Fluor. w/ (2) 48" T5 28W lamps, elec. ballast 12 Local cont /access Part of furn. Per 1512.2 001 "B1" - 4' Fluor. wl (1) 36" T5 21W (amps, elec. ballast 6 1513.2 Part of furn. Per 1512.2 001 "B2" - 4' Fluor. w/ (1) 48" T5 28W lamps, elec. ballast 21 YES Part of furn. Per 1512.2 001 "C" - 7" Comp. Fluor. w/ 42W tripl, elec. ballast 18 45.0 810.0 001 "C1" 39W CMH, electrononic ballast 12 37.0 444.0 001 "F" - 2' Track Light w/ 39W CMH, elec. Ballast 15 100.0 1500.0 002, 003, 004 "L2" - 2'x4' Fluor. w/ (2) 48" T8 32W (amps, elec. ballast 8 65.0 520.0 005A &'0056 "P" - 4' Fluor. w/ (2) 48" T8 32W lamps, elec. ballast 2 65.0 130.0 Schedule with type and features, indicate location NIA Total Proposed Watts may not exceed Total Total Proposed Watts Allowed Watts for Interior 6524.0 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall com ply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry /exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing m ore than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of turning off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A com bination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that com ply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of turning off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off" feature, which turns off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. W here the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 - TRANSFORMERS The minimum efficiency of a low voltage dry -type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). ELO?1/•-.1 Li • htin • Motor and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 16425 SOUTHCENTER PKWY Date 7/16/2008 TUKWILA, WA APPLICABILITY YES, NO, N/A CODE SECTION COMPONENT INFORMATION REQUIRED LOCATION ON PLANS BUILDING DEPARTMENT NOTES LIGHTING CONTROLS (Section 1513) YES 1513.1 Local cont /access Schedule with type, indicate locations E -101 YES 1513.2 Area controls Maximum limit per switch E -101 YES 1513.3 Daylight zone control Schedule with type and features, indicate locations E -101 YES Vertical glazing Indicate vertical glazing on plans E -101 N/A Overhead glazing Indicate overhead glazing on plans YES 1513.4 Display /exhib/ special Indicate separate controls E -101 N/A 1513.5 Exterior shut- off : Schedule with type and features, indicate location NIA (a) timer w /backup Indicate location N/A (b) photocell. Indicate location YES 1513.6 Interior auto shut -off Indicate location E -101 N/A 1513.6.1 (a) occup. sensors Schedule with type and locations YES 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans E -101 N/A 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) YES 1514 Max. watts Indicate watts for each exit sign - 5 watts E -001 LIGHTING POWER ALLOWANCE (Section 1530 -1532) YES 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture E -001 N/A 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N/A 1511 Elec Motor Efficiency MECH -MOT or Equipment Schedule with hp, rpm, efficiency TRANSFORMERS (Section 1540) N/A 1540 Transformers Indicate size and efficiency If "no" is circled for any question, provide explanation: FILE COPY permit No. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j Pier review approval is sUblect to orror3 and omisicns. /approval of construction documents . authorize � t the violation of any adopted coda or orc�na�e of approved Field Copy and conditions is acknowledged: By Date: City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 18 1008 PERMIT CENTER �OFPREVIEWED FOR COMPLIANCE 7 NEC JUL 2 9 2008 �tyOf j Rll UTNG DM tz ABATE PERMIT REQUIRED FOR: CiiMechanica1 ❑ Electrical r..�Plumbing ttn Gas Piping City of Tukwila BUILDING DIVISION ION. RE,VISI NNO. *1,0•Ehr-2---61/-1 COPYRIGHT 0 2006 CARTER & BURGESS, INC. at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 1 EXPIRES 08/26/09 ISSUES /REVISIONS 3 07 -16 -08 TENANT CHANGES 1 03 -29 -08 TENANT CHANGES NO. 03 -19 -08 ISSUE FOR PERMIT DATE DESCRIPTION 16425 Southcenter Parkway TUKWILA, WA DRAWN BY: RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: 441805.011.028.0001 NONE LIGHTING COMPLIANCE CERTIFICATE R:\JOB \Cingular\Washington State \16425 Southcenter -See's Candy, WA \Sheet \E -003.dwg, 7/17/2008 1:39:31 PM, MAGUIReMJ ELECTRICAL SPECIFICATIONS SECTION 16050: GENERAL ELECTRICAL THE DRAWINGS, GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND DIVISION 1 APPLY TO WORK UNDER THIS SECTION. PART 1 GENERAL 1.01 DESCRIPTION A. GENERAL: FURNISH ALL LABOR, MATERIALS, APPARATUS, TOOLS, EQUIPMENT, TRANSPORTATION, TEMPORARY CONSTRUCTION AND SPECIAL OR OCCASIONAL SERVICES AS REQUIRED TO MAKE A COMPLETE WORKING ELECTRICAL INSTALLATION, AS SHOWN ON THE DRAWINGS OR DESCRIBED IN THESE SPECIFICA11ONS. B. ALL ELECTRICAL MATERIAL & EQUIPMENT SHALL BE NEW AND IN PERFECT CONDITION WHEN INSTALLED. ALL EQUIPMENT SHALL BE U.L. LISTED. MATERIALS SHALL BE MANUFACTURED IN ACCORDANCE WITH APPLICABLE STANDARDS OF A.N.S.I., N.E.M.A. & N.B.F.U. REPLACE DEFECTIVE OR DAMAGED MATERIALS OR REPAIR IN A MANNER APPROVED BY THE OWNER. KEEP CONDUITS AND OTHER OPENINGS CLOSED TO PREVENT ENTRY OF FOREIGN MATTER. COVER FIXTURES, EQUIPMENT AND APPARATUS AND PROTECT AGAINST DIRT, WATER, CHEMICAL OR MECHANICAL DAMAGE BEFORE AND DURING THE CONSTRUCTION PERIOD UNTIL FINAL ACCEPTANCE. RESTORE TO ORIGINAL CONDITION ANY FIXTURES, APPARATUS OR EQUIPMENT DAMAGED PRIOR TO FINAL ACCEPTANCE, INCLUDING RESTORATION OF DAMAGED SHOP COATS OF PAINT. DELIVER EQUIPMENT AND STORE AT THE SITE, PROPERLY PACKED AND CRATED, UNTIL FINALLY INSTALLED. C. ANY INCONSISTENCY OR DISCREPANCY IN THE DRAWINGS OR SPECIFICATIONS SHALL BE CLEARED WITH THE ENGINEER. IT IS UNDERSTOOD FURTHER THAT THE CONTRACTOR HAS READ AND UNDERSTANDS FULLY THE PLANS, SPECIFICATIONS AND ALL RELATED DOCUMENTS ON THIS PROJECT. D. THE CONTRACTOR SHALL UNDERTAKE THE WORK IN ITS ENTIRETY IN ACCORDANCE WITH ITS DESIGN AND PURPOSE. ALL WORK SHALL BE CARRIED OUT IN A PROFESSIONAL MANNER WITH MAXIMUM EFFICIENCY AND EXCELLENT WORKMANSHIP. E. PERMITS AND FEES: THE CONTRACTOR SHALL SECURE AND PAY FOR PERMITS AND FEES NECESSARY FOR EXECUTION AND COMPLETION OF ELECTRICAL WORK, INCLUDING ALL CHARGES BY THE LOCAL GOVERNMENT AND CITY AGENCIES. F. SCOPE OF WORK INCLUDES, BUT NOT LIMITED TO: 1. INSTALLATION AND ASSEMBLY OF LIGHTING FIXTURES AND LAMPS. 2. GROUNDING. 3. INSTALLATION OF DUCT SMOKE DETECTORS. 4. PROVIDE PANELBOARDS AND OVERCURRENT DEVICES. 5. BRANCH CIRCUIT WIRING. 6. EXIT SIGNS AND EMERGENCY LIGHTING SYSTEM. 7. INSTALLATION OF CONVENIENCE OUTLETS. 8. INSTALLATION OF TELEPHONE BACKBOARD, TELEPHONE AND DATA OUTLETS AND RACEWAYS. 9. FURNISHING, SUPPORT AND INSTALLATION OF NEW TRANSFORMER. 10. ROUGH -IN WIRING FOR DISPLAY CASE LIGHTING. 11. DEMOLITION AND REMOVALS. 12. LIGHTING CONTROLS, AND TIME SWITCHES. 13. CONNECTIONS OF, AND POWER WRING TO, HVAC EQUIPMENT: 14. CONDUIT FOR DATA, TELEPHONE AND ALARM SYSTEMS. 15. INSTALLATION AND ASSEMBLY OF OWNER FURNISHED FIXTURES, EQUIPMENT AND DEVICES. 16. OTHER RELATED SERVICES G. RELATED WORK SPECIFIED ELSEWHERE: 1. PERFORM THE FOLLOWING WORK, IN ACCORDANCE WITH APPROPRIATE SECTIONS OF THE SPECIFICATIONS CITED, WHERE AND AS NECESSARY TO FURNISH A COMPLETE, WORKING ELECTRICAL INSTALLATION. A. CONCRETE: DIVISION 3 B. PAINTING: DIVISION 9 C. DOOR HARDWARE: DIVISION 11 D. MECHANICAL: DIVISION 15 2. PROVIDE WIRING FOR EQUIPMENT FURNISHED BY OTHERS, AS SHOWN ON DRAWINGS. COORDINATE WITH OTHER TRADES OR DETAILS FOR INSTALLATION. THE TERM "WIRING" AS USED HEREIN, INCLUDES FURNISHING AND INSTALLING CONDUIT, WIRE, JUNCTION BOXES, DISCONNECTS ETC. AND MAKING CONNECTIONS. CHECK ARCHITECTURAL AND MECHANICAL DRAWINGS AND SPECIFICATIONS FOR EQUIPMENT TO BE INSTALLED BY OTHERS. BE RESPONSIBLE FOR PROPER WIRING AND NECESSARY ELECTRICAL ADJUSTMENTS TO EQUIPMENT TO CONFORM TO SPECIFIED REQUIREMENTS OF THE EQUIPMENT. H. PENETRATIONS OF WALLS AND WALL MEMBRANES REQUIRED TO HAVE A FIRE- RESISTANCE RATING SHALL BE PROTECTED WITH THROUGH- PENETRA11ON FIRE STOPS SUITABLE FOR THE METHOD OF PENETRATION. THROUGH - PENETRATION FIRE STOPS SHALL BE TESTED USING U.B.C. STANDARD 7 -5• PROVIDE SEISMIC RESTRAINTS AND ATTACHMENTS FOR ELECTRICAL EQUIPMENT AND SYSTEM COMPONENTS AS REQUIRED PER THE STATE AND LOCAL JURISDICTIONS. J. PROVIDE 4" CONCRETE HOUSEKEEPING PAD FOR ALL FLOOR MOUNTED EQUIPMENT. 1.02 CODES AND STANDARDS: A. SPECIFIC 1. COMPLY WITH ALL CODES ENFORCED BY THE STATE AND LOCAL JU 2. ALL ELECTRICAL WORK SHALL CONFORM TO ALL REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION. 3. EQUIPMENT AND MATERIALS SPECIFIED UNDER THIS DIVISION SHALL STANDARDS WHERE APPUCABLE. A. UL UNDERWRITERS' LABORATORIES. B. ASTM AMERICAN SOCIETY FOR TESTING MATERIALS. C. CBM CERTIFIED BALLAST MANUFACTURERS. D. ANSI AMERICAN NATIONAL STANDARDS. INSTITUTE. E. NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION RISDIC11ONS. THE CURRENT UBC, NEC, AND CONFORM TO THE FOLLOWING 1.03 DRAWINGS: A. LAYOUT: GENERAL LAYOUT SHOWN ON THE DRAWINGS SHALL BE FOLLOWED EXCEPT WHERE OTHER WORK MAY CONFLICT WITH THE DRAWINGS. B. ACCURACY: 1. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. COMPLETE DETAILS OF THE BUILDING WHICH MAY AFFECT THE ELECTRICAL INSTALLATION ARE NOT SHOWN. SIZE AND LOCATION OF EQUIPMENT AND WIRING ARE SHOWN TO SCALE WHERE POSSIBLE BUT MAY BE DISTORTED FOR CLARITY ON THE DRAWINGS. FINAL LOCATIONS OF OUTLETS AND EQUIPMENT SHALL BE SHOWN IN ENLARGED DETAILS OR AS APPROVED BY THE ARCHITECT OR HIS REPRESENTATIVE. IT IS NOT WITHIN THE SCOPE OF DRAWINGS TO SHOW ALL NECESSARY BENDS, OFFSET, PULL BOXES AND OBSTRUCTIONS. CONTRACTOR SHALL PROVIDE THE INSTALLATION TO MAINTAIN HEADROOM AND KEEP OPENINGS AND PASSAGEWAYS CLEAR. COORDINATE WITH DRAWINGS OF ALL OTHER TRADES. 2. CONTRACTOR SHALL VERIFY LINES, LEVELS AND DIMENSIONS SHOWN ON THE DRAWINGS AND SHALL BE RESPONSIBLE FOR THE ACCURACY OF THE SETTING OUT OF WORK AND FOR ITS STRICT CONFORMANCE WITH EXISTING CONDITIONS AT THE SITE. 1.04 SUBSTITUTIONS: SUBSTITUTIONS OF SPECIFIED DEVICES AND EQUIPMENT SHALL NOT BE ALLOWED. 1.05 SUBMITTALS: A. GENERAL: REFER TO THE GENERAL CONDITIONS, SUPPLEMENTARY GENERAL CONDITIONS AND DIVISION 1 FOR REQUIREMENTS. B. C. FORMAT: FURNISH SUBMITTAL DATA NEATLY BOUND IN AN 8 -1/2" X 11" FOLDER OR BINDER WITH A TABLE OF CONTENTS LISTING IN ORDER OF SPECIFICATION SECTION AND PARAGRAPH NUMBER. SUBMITTALS SHALL CONSIST OF DETAILED SHOP DRAWINGS, SPECIFICATIONS, CATALOG "CUTS" AND DATA SHEETS CONTAINING PHYSICAL AND DIMENSIONED INFORMATION, PERFORMANCE DATA, ELECTRICAL CHARACTERISTICS, MATERIALS USED IN FABRICATION, MATERIAL FINISH AND THOSE OPTIONAL ACCESSORIES WHICH ARE INCLUDED AND THOSE WHICH ARE EXCLUDED. D. EACH SUBMITTAL SHALL BE THOROUGHLY REVIEWED BY THE CONTRACTOR. THE COVER LETTER ACCOMPANYING SUBMITTAL LETTER SHALL UST IN FULL THE ITEMS AND DATA SUBMITTED AND SHALL CONTAIN A STATEMENT ACKNOWLEDGING THAT THE CONTRACTOR HAS PERFORMED A DETAILED REVIEW OF THE SUBMITTAL DOCUMENTS PRIOR TO SUBMISSION. FAILURE TO COMPLY WITH THIS REQUIREMENT SHALL CONSTITUTE GROUNDS FOR RETURN OF DATA FOR RESUBMISSION WITHOUT REVIEW. E. CONTRACTOR AGREES THAT SHOP DRAWING SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS, THAT THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, THAT HE DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH EQUIPMENT AND MATERIAL HE INTENDS TO FURNISH AND INSTALL AND BY DETAILING THE FABRICATION AND INSTALLATION METHODS HE INTENDS TO USE. 1.06 PRODUCT DELIVERY, STORAGE AND HANDLING: EQUIPMENT AND MATERIALS SHALL BE PROPERLY STORED AND ADEQUATELY PROTECTED AND CAREFULLY HANDLED TO PREVENT DAMAGE BEFORE AND DURING INSTALLATION. EQUIPMENT AND MATERIALS SHALL BE HANDLED, STORED, AND PROTECTED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND AS APPROVED BY THE OWNER'S REPRESENTATIVE. ELECTRICAL CONDUIT SHALL BE STORED TO PROVIDE PROTECTION FROM THE WEATHER AND ACCIDENTAL DAMAGE. PLASTIC CONDUIT SHALL BE STORED ON EVEN SUPPORTS AND IN LOCATIONS NOT SUBJECT TO DIRECT SUN RAYS OR EXCESSIVE HEAT. CABLES SHALL BE SEALED, STORED AND HANDLED CAREFULLY TO AVOID DAMAGE TO THE OUTER COVERING OR INSULATION AND DAMAGE FROM MOISTURE AND WEATHER. DAMAGED OR DEFECTIVE ITEMS, IN THE OPINION OF THE OWNER'S REPRESENTATIVE, SHALL BE REPLACED WITH NEW ITEMS AT THE EXPENSE OF THE CONTRACTOR. PART 2 PRODUCTS (NOT APPUCABLE) PART 3 EXECUTION: 3.01 TESTS AND GUARANTEES: A. TESTS SHALL BE CONDUCTED DURING THE CONSTRUCTION PERIOD AND AT COMPLETION TO DETERMINE CONFORMITY WITH APPUCABLE CODES AND WITH THESE SPECIFICATIONS. TESTS SHALL BE PERFORMED IN THE PRESENCE OF THE ARCHITECT AND SHALL INCLUDE, BUT ARE NOT LIMITED TO, THE FOLLOWING: 1. INSULATION RESISTANCE: PERFORM 500 -VOLT D.C. TESTS FOR ONE MINUTE ON ALL FEEDER CONDUCTORS, INCLUDING THE NEUTRAL AND MAKE A TYPED RECORD OF ALL READINGS TO BE INCLUDED IN THE MAINTENANCE INSTRUCTIONS. REPAIR OR REPLACE CIRCUITS SHOWING LESS THAN 40 MEGOHMS RESISTANCE TO GROUND. MAKE TESTS USING BIDDLE INSULATION RESISTANCE MEGGER, OR EQUAL 2. GROUND RESISTANCE: TEST GROUND RESISTANCE PER IEEE STANDARD NO. 81. HIRE AN INDEPENDENT LAB TO PERFORM THE GROUNDING SYSTEM TESTING PER NETA 7.13. CERTIFIED DOCUMENTS SHALL BE PROVIDED TO THE OWNER FOR VERIFICATION PRIOR TO PROJECT COMPLETION. 3. CIRCUITS CONTINUITY: TEST ALL FEEDER AND BRANCH FOR CONTINUITY. TEST ALL NEUTRALS FOR IMPROPER GROUNDS. 4. EQUIPMENT OPERATIONS: TEST LIGHTING CIRCUITS FOR CORRECT OPERATION THROUGH THEIR CONTROL DEVICES. TEST ELECTRIC BASEBOARD HEATERS FOR CORRECT OPERATIONS THROUGH THEIR CONTROL RELAYS /THERMOSTATS. 5. LIGHTING CONTROL CIRCUITS: PERFORM OPERATION TESTS FOR ALL UGHITNG CIRCUITS. 6. PROPERLY TEST THE PHASE ROTATION OF ALL NEW FEEDERS AND BRANCH CIRCUITS, AND MAKE SUCH CHANGES AND ALTERATIONS NECESSARY TO INSURE THE CORRECT ROTATION OF ALL MOTOR DRIVEN EQUIPMENT THROUGHOUT THE NEW INSTALLATION. 7. PRODUCT FAILURE: ANY PRODUCTS WHICH FAIL DURING THE TESTS OR ARE RULED UNSATISFACTORY BY THE OWNER'S REPRESENTATIVE SHALL BE REPLACED, REPAIRED, OR CORRECTED AS PRESCRIBED BY THE OWNER'S REPRESENTATIVE AT THE EXPENSE OF THE CONTRACTOR. TESTS SHALL BE PERFORMED AFTER REPAIRS, REPLACEMENTS OR CORRECTIONS UNTIL SATISFACTORY PERFORMANCE IS DEMONSTRATED. 8. PHYSICAL INSPECTION OF ELECTRICAL EQUIPMENT AND CABLES: INSPECTION SHALL BE MADE OF ALL EQUIPMENT TO INSURE PROPER ASSEMBLY AND CONSTRUCTION. 9. FURNISH, IN WRITING, A COMPLETE GUARANTEE AGAINST DEFECTIVE MATERIALS AND IMPROPER WORKMANSHIP, SATISFACTORY TO OWNER, FOR ALL PARTS, COMPONENTS, AND OPERATION. INCLUDE IN GUARANTEE COMPLETE MAINTENANCE OF THE SYSTEM, INCLUDING REPLACEMENT PARTS, ALL LABOR AND MATERIALS TO MAINTAIN THE SYSTEM IN PROPER OPERATING CONDITION FOR THE GUARANTEE PERIOD. 3.02 INSTRUCTIONS AND MANUALS A. REFER TO DIVISION 1. B. AT THE TIME OF COMPLETION, AN ADEQUATE PERIOD SHALL BE ALLOTTED BY THE CONTRACTOR FOR INSTRUCTION OF BUILDING OPERATING AND MAINTENANCE PERSONNEL IN THE USE OF ALL SYSTEMS. ALL PERSONNEL SHALL BE INSTRUCTED AT ONE TIME, THE CONTRACTOR MAKING ALL NECESSARY ARRANGEMENTS WITH MANUFACTURER'S REPRESENTATIVES. THE EQUIPMENT MANUFACTURER SHALL PROVIDE PRODUCT LITERATURE AND APPUCA11ON GUIDES FOR THE USERS' REFERENCE. C. COSTS, IF ANY, FOR THE ABOVE SERVICE SHALL BE PAID BY THE CONTRACTOR. 3.03 PROJECT RECORD DOCUMENTS (AS- BUILT) A. PROVIDE PROJECT RECORD DRAWINGS AND SPECIFICA11ONS AS REQUIRED BY OTHER SECTIONS OF SPECIFICA11ONS AND AS REQUIRED HEREIN. SUCH DRAWINGS SHALL FULLY REPRESENT INSTALLED CONDITIONS INCLUDING ACTUAL LOCATION OF OUTLETS, CORRECT CONDUIT AND WIRE SIZING AS WELL AS ROUTING, REVISED FIXTURE SCHEDULING LISTING THE MANUFACTURER AND PRODUCTS ACTUALLY INSTALLED. B. ALL CHANGES TO DRAWINGS SHALL BE MADE BY QUALIFIED DRAFTSPERSONS TO MATCH EXISTING UNE WORK AND LETTERING AS CLOSELY AS POSSIBLE. 3.04 WORKMANSHIP A. THE CONTRACTOR SHALL UNDERTAKE THE WORK IN ITS ENTIRETY IN ACCORDANCE WITH ITS DESIGN AND PURPOSE. ALL WORK SHALL BE CARRIED OUT IN A PROFESSIONAL MANNER WITH MAXIMUM EFFICIENCY AND EXCELLENT WORKMANSHIP. PREPARATION, HANDLING AND INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND TECHNICAL DATA PARTICULAR TO THE PRODUCT SPECIFIED AND /OR APPROVED EXCEPT AS OTHERWISE SPECIFIED. COORDINATE WORK AND COOPERATE WITH OTHER IN FURNISHING AND PLACING THIS WORK. WORK TO APPROVED SHOPDRAWINGS FOR WORK BY OTHERS AND TO FIELD MEASUREMENTS AS NECESSARY TO PROPERLY FIT THE WORK. CONFORM TO THE NATIONAL ELECTRICAL CONTRACTOR'S ASSOCIATION STANDARD OF INSTALLATION FOR GENERAL INSTALLATION PRACTICE. B. C. 3.05 SCHEDULE OF WORK: ARRANGE WORK TO CONFORM TO THE SCHEDULE WHICH HAS BEEN ESTABLISHED FOR THE PROGRESS OF THE WORK. ADVISE REGARDING SHIPPING SCHEDULE OF MAJOR EQUIPMENT. 3.06 SUPERVISION: CONTRACTOR SHALL PERSONALLY OR THROUGH AN AUTHORIZED AND COMPETENT REPRESENTATIVE CONSTANTLY SUPERVISE THE WORK FROM BEGINNING TO COMPLETION AND, WITHIN REASON, KEEP THE SAME WORKMEN AND FOREMAN ON THE PROJECT THROUGHOUT THE PROJECT DURATION. 3.07 PROTECTION: KEEP CONDUITS, JUNCTION BOXES, OUTLET BOXES, AND OTHER OPENINGS CLOSED TO PREVENT ENTRY OF FOREIGN MATTER. COVER FIXTURES, EQUIPMENT AND APPARATUS AND PROTECT AGAINST DIRT, PAINT, WATER, CHEMICAL OR MECHANICAL DAMAGE, BEFORE AND DURING CONSTRUCTION PERIOD. RESTORE TO ORIGINAL CONDITION ANY FIXTURE, APPARATUS, OR EQUIPMENT DAMAGED PRIOR TO FINAL ACCEPTANCE. PROTECT BRIGHT FINISHED SURFACES AND SIMILAR ITEMS UNTIL IN SERVICE. NO RUST OR DAMAGE WILL BE PERMITTED. 3.08 SPECIAL TOOLS: ALL SPECIAL TOOLS FOR PROPER OPERATION AND MAINTENANCE OF THE EQUIPMENT PROVIDED UNDER THIS SECTION SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE. 3.09 CUTTING AND PATCHING A. CONTRACTOR SHALL CAREFULLY LAY OUT ALL WORK IN ADVANCE TO AVOID UNNECESSARY CUTTING, CHANNELING, CHASING OR DRILLING OF FLOORS, WALLS, PARTITIONS, CEILINGS OR OTHER SURFACES. STRUCTURAL MEMBERS WILL NOT BE CUT OR DRILLED WITHOUT THE APPROVAL OF THE ENGINEER AND OWNER. WHERE SUCH WORK IS NECESSARY, HOWEVER, DO ALL CUTTING, CORING AND PATCHING OF THE CONSTRUCTION WORK WHICH MAY BE REQUIRED FOR THE PROPER INSTALLATION OF THE ELECTRICAL WORK. ALL PATCHING SHALL BE OF THE SAME MATERIALS, WORKMANSHIP AND FINISH AND SHALL ACCURATELY MATCH ALL SURROUNDING WORK. AFTER COMPLETION OF WORK, CLEAN UP RESULTANT DEBRIS AND REMOVE FROM SITE. B. INSTALL ALL REQUIRED SLEEVES, FORMS AND INSETS BEFORE WALLS OR PARTITION ARE BUILT. CUTTING AND PATCHING OF WALLS, PARTITIONS, CEILINGS AND FLOOR NECESSARY FOR RECEPTION OF WORK, CAUSED BY FAILURE TO PROVIDE OR PROPERLY LOCATED SLEEVES, FORMS AND INSETS, INCORRECT LOCATION OF WORK OR FAILURE TO COOPERATE WITH OTHER TRADES, SHALL BE DONE AT EXPENSE OF TRADE RESPONSIBLE. C. NO CUTTING OF FINISHED OR STRUCTURAL WORK MAY BE DONE WITHOUT ACCEPTANCE. WHEN NECESSARY TO HAVE FINISHED MATERIAL OR STRUCTURAL WORK CUT, FURNISH NECESSARY DRAWINGS TO TRADE WHOSE MATERIALS ARE OUT TO BE CUT. 3.10 CLEARANCES: PROVIDE WORKING CLEARANCE IN FRONT OF, IN BACK OF, AND TO SIDES FOR ALL ELECTRICAL EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. 3.11 DEMOLITION: DEMOLITION AND REMOVAL OF EXISTING ELECTRICAL SERVICES TO THE EXISTING TENANT SPACE TO BE BY THE CONTRACTOR. 3.12 CONNECTIONS: CONTRACTOR SHALL PROVIDE ALL ELECTRICAL FINAL CONNECTIONS AS REQUIRED FOR COMPLETE AND OPERABLE SYSTEM U.N.O. 3.12 ACCESS PANEL B. A. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS REQUIRED FOR CODE REQUIRED ACCESS TO ELECTRICAL DEVICES AND JUNCTION BOXES IN HARD CEILING AREAS. B. ACCESS PANELS SHALL NOT BE ALLOWED IN SALES AREA CEILING OR WALLS. DEVICES AND EQUIPMENT THAT NORMALLY WOULD BE CONCEALED FROM VIEW SHALL BE LOCATED AT NORMALLY ACCESSIBLE AREAS SUCH AS ABOVE CEILING, NEAR HVAC DIFFUSERS OR IN BACK ROOMS IN ACCESSIBLE CEILING AREAS. END OF SECTION SECTION 16100: BASIC MATERIALS AND METHODS THE GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS, AND DIVISION 1 APPLY TO WORK UNDER THIS SECTION. PART 1 1.01 A. GENERAL DESCRIPTION WORK SPECIFIED IN THIS SECTION ENCOMPASSES PRODUCTS, ASSEMBLIES AND BASIC INSTALLATION METHODS REQUIRED FOR ELECTRICAL PROJECT SYSTEMS SPECIFIED UNDER THIS DIVISION AND INCLUDES, BUT IS NOT UMITED TO: 1. CONDUIT, RACEWAYS, AND FITTINGS. 2. WIRE AND CABLES. 3. WIRE CONNECTIONS AND DEVICES. 4. OUTLET BOXES. 5. PULL AND JUNCTION BOXES. 6. SWITCHES AND RECEPTACLES. 7. DEVICE PLATES. 8. OVERCURRENT PROTECTIVE DEVICES. 9. TELEPHONE TERMINAL BACKBOARD. 10. DOOR BUZZER AND PUSHBUTTON SYSTEM. 11. BACKGROUND SOUND SYSTEM EQUIPMENT INSTALLATION AND WIRING. 12. EMPTY RACEWAY PROVISIONS FOR BURGLAR ALARM AND SECURITY SYSTEM DETECTION UNITS AND SWITCHES. 13. PANELBOARDS AND ASSOCIATED EQUIPMENT B. WORK NOT INCLUDED: 1. BACKGROUND SOUND SYSTEM EQUIPMENT FURNISHED BY AUDIO CONTRACTOR. 2. BURGLAR ALARM AND SECURITY SYSTEM EQUIPMENT AND WIRING. SUBMITTALS 1.02 A. SUBMIT IN CONFORMANCE WITH THE REQUIREMENTS OF SECTION 16050 THE FOLLOWING ITEMS: 1. SWITCHES, RECEPTACLES AND DEVICE PLATES. 2. CONDUCTORS AND CABLES. 3. OVERCURRENT PROTECTIVE DEVICES. 4. RACEWAYS. 5. DOOR BUZZERS AND PUSHBUTTON. 6. PANELBOARDS AND TRANSFORMER PART 2 PRODUCTS 2.01 CONDUIT AND FITTINGS A. RACEWAYS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE, RIGID GALVANIZED STEEL CONDUIT (RGS) & ELECTRICAL METALLIC TUBING (EMT), SUBJECT TO THE RESTRICTIONS OF THE STATE ELECTRIC CODE, MINIMUM OF Y4" OR AS SPECIFIED ON DRAWINGS, AS FOLLOWS: 1. RIGID STEEL CONDUIT (RGS) la. RGS SHALL BE PERMITTED UNDER ALL CONDITIONS SUBJECT TO THE RESTRICTIONS OF THE STATE ELECTRIC CODE, EXCEPT AREAS IDENTIFIED AS A CORROSIVE ENVIRONMENT BY OWNER OR WHERE EXPOSED IN GMP CLASSIFIED ASEPTIC AREAS (CLASS 100,000 TO CLASS 100). EXPOSED CONDUITS SHALL BE RGS. 10. CONDUIT, RIGID STEEL: FULL WEIGHT, THREADED, HOT -DIP GALVANIZED, INSIDE ENAMELED, CONFORMING TO ANSI C80.1. 1b. CONDUIT AND FITTINGS SHALL BE THREADED, HOT DIPPED GALVANIZED WITH ZINC COATED THREADS AND SHALL BE IN COMPLIANCE WITH NEC, ANSI AND UL CONNECTORS SHALL HAVE INSULATED THROATS. lc. THREE -PIECE COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON. EFCOR 165 SERIES, O.Z. /GEDNEY 4 -50 SERIES OR EQUAL 1d. THREADLESS COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON, WITH INTEGRAL CONDUIT STOP. EFCOR 1760. le. THREADLESS CONNECTORS: ELECTROPLATED, CAST MALLEABLE IRON, ON THREADED MALE HUB PLASTIC INSULATED THROAT RATED 90 DEGREES C MINIMUM. EFCOR 1750B SERIES, O.Z. /GEDNEY 31 -050 1T SERIES OR EQUAL. 1f. INSULATED BUSHINGS: THREADED POLYPROPYLENE OR THERMOSETTING PHENOLIC RATED 150 DEGREES C MINIMUM. INSULATED GROUNDING BUSHINGS: THREADED CAST MALLEABLE IRON BODY WITH INSULATED THROAT AND STEEL, "LAY -IN" GROUND LUG WITH COMPRESSION SCREW. O.Z. /GEDNEY BLG SERIES, THOMAS & BETTS 3870 SERIES OR EQUAL 1h. INSULATED METALLIC BUSHINGS: THREADED CAST MALLEABLE IRON BODY WITH PLASTIC INSULATED THROAT RATED 105 DEGREES C. O.Z. /GEDNEY TYPE B, THOMAS & BETTS 1222 SERIES OR EQUAL. 1i. SUPPORT CONDUITS IN ACCORDANCE WITH NEC. 2. ELECTRICAL METALLIC TUBING (EMT) 2a. EMT SHALL BE PERMITTED FOR BOTH EXPOSED AND CONCEALED WORK - INTERIOR POWER AND LIGHTING BRANCH CIRCUITS WHERE RUN CONCEALED ABOVE SUSPENDED CEILING, IN STUD WALLS, FURRED SPACES, AND WHERE NOT EXPOSED TO MECHANICAL DAMAGE, OR ABOVE 6' FROM FLOOR. 2b. EMT SHALL NOT BE PERMITTED: a) WHERE SUBJECT TO PHYSICAL DAMAGE, INCLUDING MECHANICAL EQUIPMENT ROOMS BELOW 8' -0" AFF. b) FOR SIZES LESS THAN 2 ) " IN EXTERIOR & ROOFTOP LOCATIONS. c) IN CORROSIVE AREAS. d) IN CINDER BLOCK CONSTRUCTION. e) IN HAZARDOUS OR CLASSIFIED ASEPTIC LOCATIONS. 2c. CONDUIT: SHALL BE FORMED OF COLD ROLLED STRIP STEEL, ELECTRICAL RESISTANCE WELDED CONTINUOUSLY ALONG THE LONGITUDINAL SEAM AND HOT -DIP GALVANIZED AFTER FABRICATION. CONDUIT SHALL CONFORM TO ANSI C80.3 SPECIFICATIONS AND SHALL MEET U.L. REQUIREMENTS. 2d. FITTINGS SHALL BE COMPRESSION TYPE, STEEL, GLAND NUT AND RING TYPE ONLY. PRESSURE INDENTED DRIVE -ON AND DIE -CAST TYPES SHALL NOT BE USED. CONNECTORS SHALL HAVE INSULATED THROATS 2e. COUPLINGS: ELECTROPLATED, CAST MALLEABLE IRON, GLAND COMPRESSION TYPE, U.L. LISTED RAIN AND CONCRETE TIGHT THROUGH 1 -1/4 INCH TRADE SIZE, O.Z. /GEDNEY 6050W SERIES, EFCOR 760 SERIES OR EQUAL. SET SCREW TYPE COUPLINGS MAY BE USED IN DRY LOCATIONS, O.Z. /GEDNEY 5050 SERIES OR EQUAL 2f. CONNECTORS: GLAND COMPRESSION TYPE WITH CAST MALLEABLE IRON BODY WITH MALE HUB AND INSULATED PLASTIC THROAT 150 DEGREES C. TEMPERATURE RATED. O.Z. /GEDNEY 4050 SERIES OR EQUAL. 2g. SUPPORT CONDUITS IN ACCORDANCE WITH NEC. 3. FLEXIBLE METAWC CONDUIT 3a. FLEXIBLE METAWC CONDUIT SHALL BE PERMITTED FOR FINAL CONNECTIONS TO, SUSPENDED LIGHT FIXTURES, BETWEEN J -BOXES AND RECESSED /SURFACE MOUNTED LIGHT FIXTURES, TO OVERCOME BUILDING OBSTRUCTIONS, FOR CONNECTIONS TO VIBRATING (24" MAXIMUM), HYDRAULIC, OR PNEUMATIC EQUIPMENT, MOTORS, TRANSFORMERS AND SOLENOIDS IN DRY LOCATIONS. 3b. CONDUIT: SHALL BE FABRICATED IN CONTINUOUS LENGTHS FROM GALVANIZED STEEL STRIP, SPIRALLY WOUND AND FORMED TO PROVIDE AN INTERLOCKING DESIGN AND SHALL BE IN COMPLIANCE WITH NEC AND UL. 4' MAX. LENGTH. FLEXIBLE CONDUIT IS NOT PERMITTED IN WALLS. 3c. FITTINGS: CONNECTORS SHALL BE MADE OF THE SCREW CLAMP WITH CAST MALLEABLE IRON BODIES AND THREADED MALE HUBS WITH INSULATED THROATS. 3d. FLEXIBLE CONDUIT SHALL ONLY BE ALLOWED IN THE LENGTHS AND FOR APPLICATIONS AS ALLOWED BY THE JURISDICTION. CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING INSTALLATION THAT IS NOT IN COMPLJANCE WITH THE JURISDICTIONAL REQUIREMENTS 3e. SUPPORT CONDUITS IN ACCORDANCE WITH NEC. 4. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT 4a. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE PERMITTED FOR FINAL CONNECTIONS TO VIBRATING (24" MAXIMUM), HYDRAULIC, OR PNEUMATIC EQUIPMENT, MOTORS, TRANSFORMERS AND SOLENOIDS IN OUTDOOR AREAS, MECHANICAL AREAS AND WHERE EXPOSED TO MOISTURE. 4b. LIQUID TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE POLYVINYL CHLORIDE COVERED CONTINUOUSLY SPIRALLY WOUND GALVANIZED STEEL OR ALUMINUM STRIP WITH INTEGRAL GROUNDING CONDUCTOR AND SHALL BE IN COMPLIANCE WITH NEC AND UL. ANACONDA TYPE U.A., COLEMAN TYPE UXT1 OR EQUAL. 4' MAX. LENGTH. 4c. FITTINGS: FITTINGS SHALL BE LIQUID TIGHT, ZINC COATED STEEL. CONNECTOR BODY AND GLAND NUT SHALL BE OF CADMIUM PLATED CAST MALLEABLE IRON, WITH INSULATED THROAT, MAX. 24 ", T & B 5331 SERIES, O.Z. /GEDNEY 4Q -38 -1T SERIES, OR EQUAL. 4d. SUPPORT CONDUITS IN ACCORDANCE WITH NEC. LOcio! 2.1 2.02 1 g. 2.03 2.04 MC CABLING 1. METAL CLAD CABLE SHALL BE CONSTRUCTED IN STRICT ACCORDANCE WITH UL. THE CABLE SHALL BEAR THE UL LABEL AND MANUFACTURER'S "E" NUMBER 2. ACCEPTABLE SIZES FOR MC CABLE: 12/2 THROUGH 12/9; 10/2 THROUGH 10/ 9 AND SHALL CONTAIN COPPER CONDUCTORS ONLY, NO ALUMINUM ALLOWED 3. MANUFACTURER - AFC OR EQUAL 4. CONDUCTORS: COPPER; SOLID OR STRANDED 5. INSULATION: THERMOPLASTIC (THHN) OR EQUIVALENT; VOLTAGE RA11NG 600V; TEMPERATURE RA11NG 90'C 6. ARMOR: ALUMINUM; CORRUGATED OR SMOOTH TUBE 8. CABLE SHALL BE FIRE RATED, 1 HOUR MINIMUM OR HIGHER AS REQUIRED BY SPECIFIC INSTALLATION AREA, UL LISTED, RATED FOR USE IN CABLE TRAY, AND FOR USE IN ENVIRONMENTAL AIR PLENUMS 9. CONNECTORS: FURNISH ONLY UL LISTED MC CONNECTORS MANUFACTURED FOR MC CABLE. CONNECTORS SHALL BE STEEL; DIE CAST NOT ALLOWED. 10. MC CABUNG SUPPORTS: CADDY, OR APPROVED EQUAL. ALL SUPPORTS SHALL BE U.L. LISTED FOR THE APPLICATION, AND SHALL COMPLY WITH THE NEC. 11E -WRAPS AND STAPLES ARE NOT ACCEPTABLE. UTILIZE THE FOLLOWING: 1. SNAP -IN SUPPORTS TO FRAMING STUD, CADDY #MAC2. 2. STRAP TO FRAMING STUD, CADDY #FXC20 3. DROP -WIRE SUPPORTS, CADDY #PCS1. 4. CABLE SNAP CLIP FOR ATTACHMENT TO STRUCTURE, CADDY #SC. 5. CABLE SUPPORT FOR ATTACHMENT TO FRAMING STUD, CADDY #CJ6. 6. SUPPORT AND ANTI - RATTLE CLIP FOR MC THROUGH STUDS, CADDY #781. 11. MC CABUNG SHALL ONLY BE ALLOWED FOR APPLICATIONS AS ALLOWED BY THE JURISDICTION AND THE LANDLORD. PRIOR TO INSTALLATION, CONTRACTOR SHALL CONFIRM WITH BOTH AGENCIES, THAT MC IS PERMITTED. FOR INSTALLATIONS THAT HAVE NOT BEEN APPROVED BY BOTH AGENCIES, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF THE MC AND REPLACEMENT WITH EMT, AT THE EXPENSE OF THE CONTRACTOR. 12. MC CABUNG SHALL NOT BE ALLOWED TO RUN INTO THE PANELBOARDS. TRANSITION TO EMT BY MEANS OF A WIREWAY ABOVE PANELBOARDS, AND RUN BRANCH CIRCUITS IN EMT FROM WIREWAY TO PANELBOARDS - NO EXCEPTIONS 13. CONTRACTOR'S BID SHALL REFLECT COSTS FOR UTILIZING MC CABUNG AND /OR EMT INSTALLATION AS PERMITTED BY THE JURISDICTION AND LANDLORD. 14. MC CABLE SHALL NOT BE PERMITTED IN AREAS OPEN TO PUBLIC VIEW. WIRE AND CABLE A. GENERAL 1. WIRE AND CABLE SHALL BE INSULATED COPPER, SIZES AS INDICATED ON DRAWINGS AND SHALL NOT BE LESS THAN #12 AWG. ALL #8 AWG AND LARGER SHALL BE STRANDED. ALL #10 AWG WIRE AND SMALLER SHALL BE TYPE SOLID. VOLTAGE RATING OF INSULATION SHALL BE 600 VOLTS. 120V, 20A. CIRCUITS OVER 75 L.F. MUST BE #10 AWG MINIMUM. ALUMINUM WIRE AND CABLE SHALL NOT BE USED. 2. ACCEPTABLE MANUFACTURERS: GENERAL ELECTRIC CO., ROME CABLE, SOUTHWIRE, TRIANGLE, PWC INC., OR EQUAL. 3. INSULATION TYPES FOR ALL CONDUCTORS SHALL BE AS FOLLOWS: DESCRIPTION LOCATION DRY DAMP WET BRANCH CIRCUITS #6AWG AND SMALLER THHN THWN THWN FEEDER AND BRANCH CIRCUITS LARGER THAN #6 AWG XHHW XHHW XHHW -2 EXTERIOR FEEDER & BRANCH CIRCUIT WIRING XHHW -2 XHHW -2 XHHW -2 FEEDERS CONNECTED TO 100% RATED CIRCUIT BREAKERS XHHW -2 XHHW -2 XHHW -2 4. FIXTURE WIRE: TYPE AF. 5. COLOR CODE. COLOR CODE 120/208V PHASE A BLACK PHASE B RED PHASE C BLUE NEUTRAL WHITE ALL CONDUCTORS IN ACCORD WITH NEC AS FOLLOWS: 277/480V BROWN ORANGE YELLOW GRAY 6. EQUIPMENT GROUND WIRE SHALL BE GREEN. ISOLATED GROUND WIRE SHALL BE GREEN WITH YELLOW STRIPE. VOLTAGE RA11NG OF INSULATION SHALL BE 600 VOLTS. 7. ALL WIRES SHALL BE IDENTIFIED BY CIRCUIT NUMBERS IN ALL CABINETS, BOXES WIRING TROUGHS, OTHER ENCLOSURES, AT ALL SPLICES, TERMINATION POINTS, ETC. 8. WIRE RATED FOR 90 DEGREES C SHALL BE USED FOR CIRCUIT WIRING OF RECESSED FIXTURES, BETWEEN FIXTURES, AND THEIR ADJACENT OUTLET BOXES, AS REQUIRED FOR FIXTURE RATING AND FOR BRANCH CIRCUIT EQUIPMENT FEEDS UNDER RAISED FLOORS. 9. PROVIDE CONNECTORS SUITABLE FOR THE TYPE AND SIZE CONDUCTOR USED. JOINTS, TAPS, AND SPLICES OF WIRE #10 AND SMALLER SHALL BE MADE BY MEANS OF "IDEAL -NUT" CONNECTORS OR "3M SCOTCHLOK" SPRING CONNECTORS. #8 AND LARGER CONDUCTORS SHALL BE SPLICED WITH SCREW COMPRESSION CONNECTORS SIMILAR TO "BURNDY" TYPE KVS WITH HEAT OR COLD SHRINK JACKET. CONNECTORS SHALL BE LARGE ENOUGH TO ENCLOSE AND SECURELY FASTEN ALL STRANDS OF THE CONDUCTOR. EACH JOINT, TAP AND SPLICE IN CONDUCTOR #8 AND LARGER SHALL HAVE THE CONNECTOR VOIDS FILLED WITH ELECTRICAL INSULATION PUTTY AND BE TAPED WITH RUBBER AND COVERED WITH PLASTIC TAPE PROVIDING INSULATION NOT LESS THAN TWO HALF- LAPPED LAYERS EACH, "SCOTCH #33 ", "SCOTCH #88 ", "SUPNOT" GREY" OR EQUAL 10. PROVIDE LUBRICANT AS REQUIRED, "IDEAL WIRE LUBE" OR APPROVED EQUAL OUTLET BOXES AND COVERS A. STANDARD OUTLET BOXES: GALVANIZED, ONE- PIECE, DRAWN STEEL, KNOCK -OUT TYPE OF SIZE AND CONFIGURATION BEST SUITED TO THE APPLICATION INDICATED ON THE PLANS. MINIMUM BOX SIZE, 4 INCH SQUARE BY 1 -1/2 INCH DEEP. B. SWITCH BOXES: TWO INCH BY 3 -INCH LONG, GALVANIZED STEEL SWITCH BOXES SHALL BE USED ONLY FOR THE INSTALLATION OF SINGLE SWITCHES, INSTALL MULTIPLE SWITCHES IN STANDARD GANG BOXES WITH RAISED DEVICE COVERS SUITABLE FOR THE APPLICATION INDICATED. C. ENCLOSURES, JUNCTION BOXES, GUTTERS ETC. INSTALLED OUTSIDE OF BUILDING AND SUBJECT TO WEATHER SHALL BE WEATHERPROOF. D. JUNCTION BOXES AND PULL BOXES: LOCATE GENERALLY NOT EXPOSED IN FINISHED SPACE. WHERE NECESSARY, REROUTE RACEWAYS OR MAKE OTHER ARRANGEMENTS FOR CONCEALMENT. PROVIDE PULL BOXES AS INDICATED AND WHERE NECESSARY TO FACILITATE PULUNG OF WIRE AND COORDINATE LOCATION WITH OTHER TRADES. COVERS OF JUNCTION BOXES AND PULL BOXES SHALL BE ACCESSIBLE. FOR EMPTY RACEWAY RUNS PROVIDE PULL BOXES EVERY 100' AND AS INDICATED. COORDINATE LOCATIONS WITH OTHER TRADES. E. SET BOXES SQUARE AND TRUE WITH BUILDING FINISH. ERECT WALL AND SWITCH OUTLETS IN ADVANCE OF FURRING AND FIRE PROOFING. SECURE TO BUILDING STRUCTURE BY ADJUSTABLE STRAP IRONS. F. JUNCTION BOXES & PULL BOXES SHALL BE SIZED IN ACCORDANCE WITH NEC. SWITCHES AND RECEPTACLES A. GENERAL: COLOR OF DEVICES SHALL BE WHITE UNLESS OTHERWISE NOTED. ORANGE FOR DEDICATED I.G. RECEPTACLES . BLACK AT SALES AREAS WHERE LOCATED ABOVE 12' A.F.F. B. C. 1. ALL GENERAL PURPOSE 20 AMPERE, 125 -250 VOLT RECEPTACLES AND 120 -277 VOLT SWITCHES SHALL CONFORM TO NEMA WD 1 AND APPLICABLE U.L. TESTS. RECEPTACLES: REV CODE NFP JUL 8 .... LDYI 1. GROUND FAULT CIRCUIT INTERRUPTER RECEPTACLE: NEMA TYPE 5 -20R LEVITON #6898 -HG OR EQUAL 2. DUPLEX RECEPTACLES: NEMA TYPE 5 -20R, HEAVY DUTY SPECIFICATION GRADE, SIDE WIRED ONLY, LEVITON 5243 OR EQUAL 3. CASH REGISTER RECEPTACLES: NEMA TYPE 5 -20R, HEAVY DUTY SPECIFICATION GRADE, SIDE WIRED ONLY, HUBBELL G -5362, PROVIDED WITH GREEN INSULATED GROUND WIRE, AND WITH ENGRAVED COVER PLATE " "FOR CASH REGISTERS ONLY". SWITCHES: TWENTY AMPERE, 120 -277 VOLTS, FAST MAKE -SLOW BREAK, QUIET TYPE SWITCH WITH SILVER CADMIUM ALLOY CONTACTS, BINDING HEAD TERMINAL SCREWS, SIDE WIRED ONLY. ALL SWITCHES SHALL BE WHITE IN COLOR. 1. SINGLE POLE, SINGLE THROW, LEVITON #1221 OR EQUAL. 2. THREE -WAY, LEVITON #1223 OR EQUAL CITY OF OF JUL 18 2008 PERMIT CENTER COPYRIGHT 0 2008 CARTER & BURGESS. INC. at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 07 -16 -08 EXPIRES 08/26/09 ISSUES /REVISIONS 1 03 -29 -08 TENANT CHANGES NO. 03 -19 -08 ISSUE FOR PERMIT DATE DESCRIPTION 16425 Southcenter Parkway TU KW I LA, WA rEWED �....:_. '�OMPLLgNC ;37P %C E 2 9 2g Tukwila L.�DIVI ION. DRAWN BY: RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: 441805.011.028.0001 NONE ELECTRICAL SPECIFICATIONS E -003 R:\.IOB\Cingular\Washington State \16425 Southcenter -See's Candy, WA\Sheet\E-004.dwg, 7/17/2008 1:39:44 PM, MAGUIReMJ ELECTRICAL SPECIFICATIONS (CONTINUED) 2.05 DEVICE PLATES Z12 A. FLUSH DEVICE PLATES: PLATES SHALL BE SMOOTH PLASTIC, COLOR TO MATCH DEVICE, LEVITON #8600 SERIES OR EQUAL B. SURFACE MOUNTED DEVICES, INDOOR: GALVANIZED METAL TO FIT BOX. C. OUTDOOR, WEATHERPROOF: DIE CAST ALUMINUM CONSTRUCTION, CORROSION RESISTANT, HEAVY DUTY, HINGED COVER FLAP, AND GASKET, LEVITON #6196, HORIZONTAL MOUNTING. 2.06 DISCONNECT SWITCHES A. SWITCH INTERIOR: DEAD -FRONT CONSTRUCTION WITH HINGED ARC SUPPRESSOR AND SWITCH BLADES WHICH ARE FULLY VISIBLE IN THE "OFF "" POSITION AND WITH DOOR OPEN. B. SWITCH MECHANISM: QUICK -MAKE AND QUICK -BREAK OPERATING HANDLE AND MECHANISM WITH DUAL COVER INTERLOCK TO PREVENT UNAUTHORIZED OPENING OF THE SWITCH DOOR IN THE "ON" POSITION OR CLOSING THE SWITCH MECHANISM WHILE THE DOOR IS OPEN. C. RATINGS: SWITCHES SHALL BE HORSEPOWER RATED FOR THE OPERATING VOLTAGE AND WITH FUSED OR NON -FUSED ARRANGEMENTS AS SHOWN ON THE DRAWINGS. D. ENCLOSURES: NEMA 1, CODE GAUGE SHEET STEEL WITH HINGED COVER, OR NEMA 3R AS SHOWN ON DRAWINGS, AND AS REQUIRED BY APPLICATION. 2.07 TRANSFORMERS A. TRANSFORMERS SHALL BE INDOOR TYPE, SELF COOLED, 480V, THREE- PHASE, DUAL WINDING, FULLY ENCLOSED, VENTILATED, GENERAL PURPOSE DRY TYPE, 480 VOLT PRIMARY, 120/208 VOLT SECONDARY, 60 HERTZ, EQUIPPED WITH TWO 2 1/2% FULL CAPACITY TAPS ABOVE AND BELOW RATED VOLTAGE AND SHALL BE OF THE KVA RATING SHOWN ON THE DRAWINGS. TRANSFORMERS SHALL HAVE COPPER OR ALUMINUM WINDINGS CLASS 'H' INSULATION GROUP, WITH TEMPERATURE RISE, WHEN OPERATED CONTINUOUSLY AT FULL LOAD AND RATED FREQUENCY, NOT EXCEEDING 150 DEGREE C. RISE OVER 40 DEGREE C. AMBIENT, UNLESS MENTIONED OTHERWISE ON THE ONE UNE DIAGRAM. B. C. D. E. F. G. H. TRANSFORMER SHALL HAVE A MINIMUM OF 10% OVERLOAD CAPACITY AT RATED VOLTAGE AND SHALL HAVE A 10 KV BIL RATING. SOUND LEVEL AT ANY LOAD SHALL NOT EXCEED 45 DB WHEN TESTED IN A ROOM WITH AMBIENT SOUND LEVEL NOT EXCEEDING 24 DB. EXCESSIVELY NOISY TRANSFORMERS SHALL BE REPLACED WITH NEW AT THE EXPENSE OF THE CONTRACTOR. TRANSFORMER IMPEDANCE SHALL NOT BE LESS THAN 4% NOR GREATER THAN 5 %. TRANSFORMERS SHALL CONFORM TO NEMA, NEC AND ALL APPLICABLE STATE AND LOCAL CODES. TRANSFORMER SHALL NOT CONTAIN ANY PCB'S (POLYCHLORINATED BIPHENYLS). TRANSFORMER SIZE SHALL FIT SPACE ALLOCATED PER DRAWINGS. MANUFACTURER SHALL BE GE, SIEMENS, CUTLER HAMMER, OR SQUARE D. ELECTRICAL CONTRACTOR SHALL PROVIDE TRANSFORMER AS INDICATED ON THE PLANS. 2.08 PANELBOARDS A. RATINGS: SEE PANEL SCHEDULES. PANEL BOARDS SHALL BE OF THE "DEAD FRONT" ENCLOSED TYPE, FLUSH OR SURFACE MOUNTED AS REQUIRED TO FIT IN THE SPACE INDICATED ON THE PLANS, IN STEEL CABINETS, CODE GAUGE, WITH STEEL TRIM CONCEALED HINGES, DOORS, AND FLUSH TYPE LOCKS, ALL KEYED AUKE, GE, SIEMENS, CUTLER HAMMER, OR SQUARE -D, OR APPROVED EQUAL B. FINISH: ALL PAINTED STEEL WORK SHALL BE TREATED WITH A PRIMER COAT AND FINISH COAT OF THE MANUFACTURER'S STANDARD GRAY COLOR OR ANSI 61. C. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL PANELBOARDS AS INDICATED ON THE PLANS. D. BUSSES, INCLUDING NEUTRAL AND GROUND BUS SHALL BE RECTANGULAR CROSS SECTION FULL LENGTH, MINIMUM 98% CONDUCTIVITY, HARD DRAWN COPPER. SILVER OR TIN PLATED JOINTS, AND SIZED ON THE BASIS OF 1000 AMPERES PER SQ. IN. CROSS SECTIONAL AREA. BUSSES SHALL BE ARRANGED FOR SEQUENCE PHASING. E. EACH PANELBOARD SHALL BE EQUIPPED WITH A GROUND BUS SECURED TO THE INTERIOR OF THE ENCLOSURE. THE BUS SHALL BE EQUAL TO THE PANELBOARD NEUTRAL BUS AND SHALL HAVE A SEPARATE LUG FOR EACH GROUND CONDUCTOR. NOT MORE THAN ONE CONDUCTOR SHALL BE INSTALLED PER LUG. F. EACH ISOLATED GROUND PANELBOARD SHALL BE EQUIPPED WITH A ISOLATED GROUND BUS SECURED TO THE INTERIOR OF PANELBOARD WITH A SEPARATE ISOLATED GROUND WIRE (SIZED PER THE NEC) RUN BACK TO THE GROUNDING ELECTRODE G. PRIOR TO ORDERING, THE ELECTRICAL CONTRACTOR SHALL CONFIRM WITH THE SERVING UTILITY AND THE LANDLORD, THE AVAILABLE FAULT CURRENT LEVEL AT THE TENANT DISCONNECT. TENANT PANELBOARDS SHALL BE ORDERED WITH AN AIC RATING GREATER THAN THE AVAILABLE FAULT CURRENT LEVEL IF CONTRACTOR DOES NOT CONFIRM FAULT CURRENT LEVEL, FULLY RATED EQUIPMENT AT 65K AIC MINIMUM SHALL BE PROVIDED. H. BACK BOXES SHALL BE CONSTRUCTED OF CODE GAUGE STEEL W/ GALVANIZED TRIMS AND RUST INHIBITED COATING AND PAINTED WITH GRAY ENAMEL FINISH (ANSI 61). I. DOORS AND TRIM SHALL EACH BE IN ONE PIECE SO DESIGNED THAT DOORS WILL OPEN 180 DEGREES. DOORS SHALL BE FASTENED TO TRIMS WITH SEMI - CONCEALED FIVE KNUCKLE STEEL WITH NONFERROUS PINS. TRIMS SHALL BE FASTENED TO BACK BOXES BY SCREWS. J. CLEAN, VACUUM AND TIGHTEN ALL CONNECTORS AND CONNECTIONS IN EXISTING & NEW ELECTRICAL EQUIPMENT. SEAL EXISTING PANEL KNOCKOUTS NOT REUSED. K. CIRCUIT BREAKERS PROVIDED IN EXISTING PANELBOARDS SHALL MATCH EXISTING TYPE, MAKE & AIC RATING. 2.09 PROTECTIVE DEVICES A. PANEL BOARDS SHALL BE EQUIPPED WITH BOLT ON, MOLDED CASE, THERMAL MAGNETIC TRIP CIRCUIT BREAKERS OF THE TYPE, # OF POLES, TRIP SIZES, AS SHOWN IN THE DRAWINGS. PANEL BOARD AND PROTECTIVE DEVICES SHALL BE "FULLY RATED" WITH INTERRUPTING RATINGS EQUAL TO OR GREATER THAN SYSTEM AVAILABLE SHORT CIRCUIT CURRENT AT INCOMING LINE TERMINALS, AND NOT LESS THAN 10,000 A.I.C. FOR 120/208V AND NOT LESS THAN 14,000 A.I.C. FOR 480/277V. B. CIRCUIT BREAKERS: MOLDED CASE, BOLT -ON, THERMAL MAGNETIC TYPE, 40 DEGREES C. AMBIENT TEMPERATURE COMPENSATED, FIXED MOUNTING, WITH QUICK -MAKE AND QUICK -BREAK SWITCHING MECHANISM MECHANICALLY TRIP -FREE FROM THE OPERATING HANDLE. C. RATINGS: REFER TO DRAWINGS AND PANEL SCHEDULES FOR TRIP FRAME AND POLES REQUIRED. EQUIPMENT SHALL BE FULLY RATED BASED ON AVAILABLE FAULT CURRENT LEVEL D. MANUAL MOTOR STARTERS: FRACTIONAL H.P. 1 PHASE MOTORS SHALL BE PROTECTED BY THERMAL O.L. RELAY INTEGRAL WITH THE DISCONNECT: "MOTOR- MINDER ", OR EQUAL 2.10 ELECTRICAL SUPPORTING DEVICES A. PROVIDE SUPPORT DEVICES AND APPURTENANCES INCLUDING HANGERS, ANCHORS, SLEEVES, INSERTS, SEALS, AND ASSOCIATED FASTENERS USED FOR MOUNTING RACEWAYS, EQUIPMENT AND OTHER ELECTRICAL ITEMS AS REQUIRED. B. CONDUIT STRAPS: HOT -DIP GALVANIZED, CAST MALLEABLE IRON, ONE HOLE TYPE STRAP WITH CAST CLAMP -BACKS AND SPACERS AS REQUIRED. O.Z. /GEDNEY #14 -50G STRAP AND #141G SPACER, REFCOR #231 STRAP AND #131 SPACER, OR EQUAL C. CONSTRUCTION CHANNEL 1 -1/2 INCH BY 1 -1/2 INCH 12 GAUGE GALVANIZED STEEL CHANNEL WITH 17/32 INCH DIAMETER BOLT HOLES, 1 -1/2 INCHES ON CENTER, IN BASE OF THE CHANNEL. KINDORF 905 SERIES, UNISTRUT P- 1000 -HS, OR EQUAL D. FASTENERS (GENERAL): WOOD SCREWS FOR FASTENING TO WOOD. MACHINE SCREWS FOR FASTENING TO STEEL TOGGLE BOLTS FOR FASTENING TO HOLLOW CONCRETE BLOCK, GYPSUM BOARD OR PLASTER WALL. EXPANSION ANCHORS FOR ATTACHMENTS TO PRE - POURED CONCRETE. 2.11 IDENTIFYING DEVICES A. PANELBOARD DIRECTORIES: A CIRCUIT DIRECTORY WITH METAL FRAME AND GLASSINE PAGE SHALL BE PROVIDED ON THE INSIDE OF THE DOOR UPON COMPLETION OF THE PROJECT. THE DIRECTORY SHALL BE TYPEWRITTEN, INDICATING THE SERVICE CONTROLLED BY EACH CIRCUIT FOR NEW AND EXISTING PANELS. THE ROOM NUMBERS USED SHALL BE VERIFIED WITH THE OWNER AND SHALL NOT NECESSARILY BE THOSE USED IN THE DRAWINGS. B. WIRE & TERMINAL MARKERS: SELF- ADHERING, PRE - PRINTED VINYL WITH SELF - LAMINATING WRAP GROUND STRIP BRADY B191 SERIES, THOMAS & BETTS WSI SERIES, OR EQUAL C. PROVIDE NAMEPLATES, ENGRAVED, THREE LAYER LAMINATED PLASTIC W/ WHITE LETTERS ON A BLACK BACKGROUND AND 1/4" LETTERS FOR EQUIPMENT DESIGNATION AND 1/8" LETTERS FOR SOURCE CIRCUIT. NUMBER FOR THE FOLLOWING (BUT NOT UMITED TO) EQUIPMENT; PANEL BOARDS, SWITCHBOARDS INCLUDING EACH INDIVIDUAL DEVICE OR PIECE OF EQUIPMENT WITHIN THE SWITCHBOARD, MOTOR CONTROL CENTER (MCC) INCLUDING EACH DEVICE WITHIN THE MCC AND ENCLOSED SWITCHES, STARTERS, CONTACTORS, CIRCUIT BREAKERS AND TRANSFORMERS. PLYWOOD BACKBOARDS A. WHERE INDICATED FOR TELEPHONE OR COMMUNICATION SYSTEM TERMINALS, OR FOR MOTOR CONTROL OR OTHER EQUIPMENT ASSEMBLES, PROVIDE BACKBOARDS OF SIZE INDICATED. 1. USE DOUGLAS FIR PLYWOOD, EXTERIOR GRADE WITH "B" FACE, PRIME AND FINISHED PAINTED. 2. UNLESS OTHERWISE INDICATED, PROVIDE 3/4 INCH THICK PLYWOOD. 3. ALL PLYWOOD SHALL BE FIRE RESISTANT. GROUNDING GREEN, INSULATED COPPER GROUNDING CONDUCTORS SHALL BE FURNISHED TO EACH PANEL AND /OR DEVICE. RACEWAYS /CONDUITS SHALL NOT BE REUED UPON FOR EQUIPMENT GROUNDING. BRANCH/FEEDER CONDUITS SHALL INCLUDE A GROUND CONDUCTOR SIZED PER NEC. GROUND ALL CONDUITS, CABINETS, MOTORS, BOXES, ENCLOSURES, PANELS AND OTHER EXPOSED NON- CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH ALL PROVISIONS OF THE NEC ARTICLE 250 AND LOCAL CODES THAT MAY APPLY. 2.13 A. B. C. D. E. F. 2.14 A. B. C. D. 2.15 A. B. PART 3 3.01 A. B. ELECTRICALLY GROUND METALLIC BOXES. WHERE WIRING TO ITEM INCLUDES GROUNDING CONDUCTOR, PROVIDE GROUNDING TERMINAL IN INTERIOR OF BOX. ENCLOSURES OF EQUIPMENT, RACEWAYS, AND FIXTURES SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED. PROVIDE CODE- SIZED, (UNLESS OTHERWISE INDICATED) COPPER, INSULATED GREEN EQUIPMENT GROUND WITH ALL BRANCH AND FEEDER CIRCUIT RUNS. EQUIPMENT GROUND SHALL ORIGINATE AT PANELBOARD GROUND BUS AND SHALL BE BONDED TO ALL SWITCH AND RECEPTACLE BOXES AND ELECTRICAL EQUIPMENT ENCLOSURES. BUILDING SERVICES SHALL BE GROUNDED TO BUILDING STEEL AND TO COLD METALLIC WATER PIPING. ISOLATED GROUND CONDUCTORS SHALL TERMINATE ON ISOLATED GROUND BUS AND RECEPTACLE ISOLATED GROUND LUGS ONLY. DOOR BUZZER AND PUSHBUTTON SYSTEM PROVIDE A COMPLETE AND OPERATING DOOR BUZZER SYSTEM WITH ALL NECESSARY ACCESSORIES, TRANSFORMER AND WIRING. BUZZERS SHALL BE EDWARDS #1064 -G5, MOUNTED 8' AFF IN STOCK AND MEZZANINE AREAS, AND 2' AFF UNDER CASH WRAP COUNTER. PUSHBUTTON SHALL BE EDWARDS #1786 -B, MOUNT AT 4' AFF. TRANSFORMER RATED 20 VA, 24VAC SHALL BE EDWARDS #592, MOUNT AT 8' AFF LIGHTING CONTROL SYSTEM PROVIDE A COMPLETE AND OPERATING LIGHTING CONTROL SYSTEM WITH ALL NECESSARY ACCESSORIES, RELAYS, WIRING, CONTACTORS, PHOTOELECTRIC DEVICE, AND PROGRAMMING. PROVIDE ALL PROGRAMMING AS REQUIRED TO ACCOMMODATE THE OWNER'S SCHEDULING. PROVIDE TRAINING TO THE OWNER, FOR OPERATING THE TIMECLOCK. EXECUTION CONDUIT INSTALLATION GENERAL 1. CONDUIT SYSTEM SHALL BE CONCEALED UNLESS EXPOSED WORK IS CLEARLY CALLED FOR ON DRAWINGS. 2. CONDUITS SHALL BE TIGHTLY COVERED AND WELL PROTECTED DURING CONSTRUCTION USING METALUC BUSHINGS AND BUSHING "PENNIES" TO SEAL OPEN ENDS. 3. IN ALL EMPTY CONDUITS OR DUCTS, INSTALL A 200 -POUND TENSILE STRENGTH POLYETHYLENE PULLING ROPE (INCLUDING ALL COMMUNICATION CONDUITS). 4. CONDUIT SYSTEMS SHALL BE ELECTRICALLY CONTINUOUS THROUGHOUT. INSTALL CODE SIZE, INSULATED, COPPER, GREEN GROUNDING CONDUCTOR IN ALL CONDUIT RUNS PULLED WITH PHASE AND NEUTRAL CONDUCTORS. 5. SIZE RACEWAYS AS REQUIRED BY NEC (OR LARGER IF SHOWN ON THE DRAWINGS) EXCEPT THAT MINIMUM SIZE SHALL BE 3/4" UNLESS SPECIFICALLY NOTED TO THE CONTRARY. EXCEPT THAT 1/2" FLEXIBLE METAL CONDUIT MAY BE USED FOR TAP CONNECTIONS BETWEEN LIGHTING FIXTURES AND JUNCTION BOXES. LAYOUT 1. LOCATIONS OF CONDUIT RUNS SHALL BE PLANNED IN ADVANCE OF THE INSTALLATION AND COORDINATED WITH THE DUCTWORK, PLUMBING, CEILING AND WALL CONSTRUCTION IN THE SAME AREAS AND SHALL NOT UNNECESSARILY CROSS OTHER CONDUITS OR PIPE, NOR PREVENT REMOVAL OF CEILING OR TILES OR PANELS, NOR BLOCK ACCESS TO MECHANICAL OR ELECTRICAL EQUIPMENT. 2. EXACT ROUTING OF CONDUIT WITHIN BUILDING SHALL BE DETERMINED BY THE CONTRACTOR. ANY COST REQUIRED TO ROUTE CONDUIT DIFFERENT THAN IT IS SHOWN ON THESE DRAWINGS SHALL BE INCURRED BY THE CONTRACTOR. CONDUIT RUNS SHALL BE ROUTED AT RIGHT ANGLES OR PARALLEL TO STRUCTURAL MEMBERS, WALLS, FLOOR OR CEILING AND SUPPORTED AT INTERVALS NO GREATER THAN 10' -0 ". 3. WHERE PRACTICAL, INSTALL CONDUITS IN GROUPS, IN PARALLEL, FOR VERTICAL AND HORIZONTAL RUNS AND AT ELEVATIONS THAT AVOID UNNECESSARY OFFSETS. 4. PASS RACEWAYS OVER & MAINTAIN A SEPARATION OF NOT LESS THAN 12 INCHES FROM PARALLEL RUNS OF HEATED PIPE LINES AND FLUES OR 3 INCHES FROM SUCH LINES CROSSING PERPENDICULAR TO THE RUNS.. WHEN RACEWAYS AND HEATED PIPE LINES ARE CLOSER THAN 6 INCHES, INSTALL ONE -PIECE INSULATION JACKETED WITH EMBOSSED VAPOR BARRIER LAMINATED ON CONDUIT. WHERE AVAILABLE, JACKET FLAPS WITH FACTORY- APPLIED PRESSURE SENSITIVE ADHESIVE MAY BE REQUIRED. 5. AT FLUSH FLOOR RECEPTACLE LOCATIONS, ASSOCIATED CONDUIT- SHALL BE RUN WITHIN WOOD FLOORING PLYWOOD UNDERLAYMENT. COORDINATE LAYOUT WITH FLOORING CONTRACTOR PRIOR TO UNDERLAYMENT INSTALL TO ACCOMMODATE CONDUIT CUT -OUTS IN PLYWOOD. CONDUIT LAYOUT SHALL NOT BE PARALLEL WITH WOOD FLOOR PLANKS SCHEDULED FOR INSTALL ON TOP OF UNDERLAYMENT. MAINTAIN MINIMUM 30 DEGREE ANGLE FROM PARALLEL C. SUPPORTS 1. ALL RACEWAY SYSTEMS SHALL BE SECURED TO THE BUILDING STRUCTURES USING SPECIFIED FASTENERS, CLAMPS AND HANGERS SPACED ACCORDING TO CODE REQUIREMENTS. 2. SUPPORT SINGLE RUNS OF CONDUIT USING ONE HOLE PIPE STRAPS. WHERE RUN HORIZONTALLY ON WALLS IN DAMP OR WET LOCATION, INSTALL "CLAMP- BACKS" TO SPACE CONDUIT OFF THE SURFACE. 3. MULTIPLE CONDUIT RUNS SHALL BE SUPPORTED USING "TRAPEZE" HANGERS FABRICATED FROM SPECIFIED CONSTRUCTION CHANNEL, MOUNTED TO 3/8 INCH DIAMETER, THREADED STEEL RODS SECURED TO BUILDING STRUCTURES., FASTEN CONDUIT TO CONSTRUCTION CHANNEL WITH STANDARD ONE HOLE PIPE CLAMPS OR THE EQUIVALENT. D. TERMINATION AND JOINTS 1. RACEWAYS SHALL BE JOINED USING SPECIFIED COUPLING OR TRANSITION COUPLINGS WHERE DISSIMILAR RACEWAY SYSTEMS ARE JOINED. 2. CONDUITS SHALL BE SECURELY FASTENED TO CABINETS, BOXES AND GUTTERS USING TWO LOCKNUTS AND AN INSULATING BUSHING OR SPECIFIED INSULATED CONNECTORS. INSTALL GROUNDING BUSHINGS OR BONDING JUMPERS ON ALL CONDUITS TERMINATING AT CONCENTRIC KNOCKOUTS. IN PANELS, PULL BOXES, OUTLET BOXES, GUTTERS, ETC. CONDUCTORS SHALL BE TIED WITH PLASTIC 11ES, NEATLY FANNED OUT AND TAGGED WITH ADHESIVE MARKERS. (3M, BRADY OR APPROVED EQUAL) WHICH ARE CLEARLY MARKED WITH CIRCUIT NUMBERS, ALL IN AN APPROVED WORKMANLIKE MANNER. 3. CONDUIT TERMINATIONS EXPOSED AT WEATHERPROOF ENCLOSURES AND CAST OUTLET BOXES SHALL BE MADE WATERTIGHT USING SPECIFIED CONNECTORS AND HUBS. 4. INSTALL EXPANSION FITTINGS ON CONDUIT RUNS EVERY 200 FEET OF LINEAR RUN, WHEREVER STRUCTURAL EXPANSION JOINTS ARE CROSSED OR WHERE REQUIRED BY THE PROJECT CONDITIONS. EXPANSION FITTINGS SHALL HAVE GROUND JUMPER AND INTERNAL BEARING ASSEMBLY. MISCELLANEOUS FITTINGS FOR CONDUIT SUCH AS REDUCERS, CHASE NIPPLES, LONG OR SHORT NIPPLES AND PLUGS SHALL BE USED AS APPLICABLE. THREE PIECE AND SPUT COUPLINGS SHALL BE USED FOR RENOVATION OR ADD -ON WORK ONLY WHERE NECESSARY. 5. CUT CONDUIT ENDS SQUARE, REAM SMOOTH, PAINT MALE THREADS OF FIELD THREADED RACEWAYS WITH GRAPHITE BASE PIPE COMPOUND. DRAW UP 11GHT WITH RACEWAY COUPLINGS. 6. EACH END OF ANY CONDUIT RUN TERMINATING IN A SHEET METAL BOX OF ANY KIND SHALL BE PROVIDED WITH GALVANIZED LOCK NUT INSIDE AND OUTSIDE OF THE BOX WITH INSULATED BUSHING ON END OF CONDUIT. 7. CAP UNUSED KNOCKOUT HOLES WHERE BLANKS HAVE BEEN REMOVED AND PLUG UNUSED CONDUIT HUBS. USE BLANK PLATES ON OUTLET BOXES IN WHICH NO DEVICE IS INSTALLED. E. PENETRATIONS 1. ALL FLOOR PENETRATIONS SHALL BE SEALED WATER- 11GHT. MAINTAIN FIRE RATING AS REQUIRED. 2. FIRE -SAFE ALL RATED WALL PENETRATIONS USING 3M LISTED FIRE - SAVNG SEALANTS AND ASSEMBLIES. 3.02 CABLE AND WIRE INSTALLATION A. GENERAL 1. CONDUCTORS SHALL NOT BE INSTALLED IN CONDUIT UNTIL ALL WORK OF ANY NATURE THAT MAY CAUSE DAMAGE IS COMPLETED. CARE SHALL BE TAKEN IN PULUNG CONDUCTORS SO THAT INSULATION IS NOT DAMAGED. U.L. APPROVED NON - PETROLEUM BASE AND INSULATING TYPE PULUNG COMPOUND SHALL BE USED AS NEEDED. 2. ALL CABLES SHALL BE INSTALLED AND TESTED IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS AND WARRANTY. B. SPLICING AND TERMINATING 1. ALL ASPECTS OF SPLICING AND TERMINATING SHALL BE IN ACCORDANCE WITH CABLE MANUFACTURER'S PUBLISHED PROCEDURES. 2. MAKE UP ALL SPLICES IN OUTLET BOXES WITH CONNECTORS AS SPECIFIED HEREIN WITH SEPARATE TAILS OF CORRECT COLOR TO BE MADE UP TO SPLICE. PROVIDE AT LEAST SIX (6) INCHES OF TAILS PACKED IN BOX AFTER SPLICE IS MADE UP. 3. ALL WIRE AND CABLE IN PANELS, TERMINAL CABINETS AND EQUIPMENT ENCLOSURES SHALL BE BUNDLED AND CLAMPED. C. MC CABLE INSTALLATION 1. INSTALL CABLE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND IN STRICT ACCORDANCE WITH NFPA 72. 2. USE SOLID CONDUCTOR FOR BRANCH CIRCUITS 12 AWG AND SMALLER. 3. BEND CABLE PER NEC. 4. GROUNDING: ALL CABLE SHALL CONTAIN A GREEN WIRE GROUND. THE JACKET SHALL NOT SERVE AS THE ONLY GROUNDING MEANS. 5. SUSPENSION: 1. CABLE SHALL BE STRAPPED TIGHT TO UNDERSIDE OF DECKING WHERE PRACTICAL. 2. CABLE SHALL HAVE INDEPENDENT SUSPENSION AND SHALL NOT BE 11ED TO CEILING GRID SUSPENSION SYSTEM, PLUMBING PIPING, OR SPRINKLER PIPING. 3. CABLE SHALL BE GROUPED SEPARATELY FROM LOW VOLTAGE CABLE SYSTEMS. 4. SUPPORT CABLE EVERY 6 FEET, MAXIMUM. 5. CABLE SHALL BE STRAPPED EVERY 6' -0', AT EACH TURN, AND WITHIN 12 INCHES OF ALL JUNCTION BOXES USING CABLE STRAPS, NOT TIES. 6. BUNDLING: INSTALL NO MORE THAN 4 CABLES TOGETHER IN A SINGLE BUNDLE 6. ROUTING: 1. BENDING RADIUS SHALL BE APPROXIMATELY 12 TIMES THE EXTERNAL DIAMETER OF THE METAL SHEATH. 2. ROUTING OF THE CABLE SHALL FOLLOW THE ORTHOGONAL GRID OF THE BUILDING STRUCTURAL ELEMENTS OF THE BUILDING, SUCH AS BEAMS AND PURLINS. 3. CABLE IN CEILINGS SHALL RUN AS 11GHT TO STRUCTURE AS POSSIBLE, AND IN NO CASE (WITH THE EXCEPTION OF DROPS) LESS THAN 12 INCHES ABOVE ACCESSIBLE CEILINGS. 4. MC CABLE SHALL NOT BE USED IN FINAL HOMERUN CONNECTION TO THE BRANCH CIRCUIT PANEL 5. ISOLATED GROUND CIRCUITS AND NORMAL GROUND CIRCUITS SHALL BE RUN IN SEPARATE CABLES. 6. CABLE SHALL BE INSTALLED USING BUSHINGS OR BUSHED FITTINGS. 3.03 INSTALLATION OF BOXES AND WIRING SERVICES A. GENERAL 1. ALL OUTLETS SHALL FINISH FLUSH WITH WALL FINISHES AND CEIUNG, EXCEPT WHERE EXPOSED WORK IS CALLED FOR. THERE SHALL BE NO GAP BETWEEN BOX AND WALL OR CEIUNG MATERIAL ANY OPENING BETWEEN BOX AND WALL OR CEILING SHALL BE CAULKED AIRTIGHT. 2. INSTALL RAISED DEVICE COVERS ON ALL OUTLET BOXES AS REQUIRED TO FINISH FLUSH WITH SURFACE. COVERS SHALL BE OF A DEPTH TO SUIT THE WALL OR CEILING FINISH. 3. LEAVE NO UNUSED OPENINGS IN ANY BOX. INSTALL CLOSE -UP PLUGS AS REQUIRED TO SEAL OPENINGS. 4. EXPOSED OUTLET BOXES AND BOXES IN DAMP AND WET LOCATIONS SHALL BE CAST METAL WITH GASKETED CAST METAL COVER PLATES. B. BOXES LAYOUT 1. OUTLET BOXES SHALL BE INSTALLED AT THE LOCATIONS AND ELEVATIONS SHOWN ON THE DRAWINGS OR SPECIFIED HEREIN. MAKE ADJUSTMENTS TO LOCATIONS AS REQUIRED BY STRUCTURAL CONDITIONS AND TO SUIT COORDINATION REQUIREMENTS OF OTHER TRADES. 2. OUTLET BOXES IN STUD WALL AND PARTITIONS SHALL NOT BE MOUNTED BACK -TO -BACK NOR SHALL THROUGH -WALL BOXES BE PERMITTED. 3. WHERE INSTALLATION IS WITHIN OR BEHIND CASEWORK, COORDINATE EXACT LOCATION WITH CASEWORK CONTRACTOR PRIOR TO ROUGH -IN TO ENSURE ACCESSIBILITY. C. SUPPORTS 1. BOXES INSTALLED IN STUD WALLS SHALL BE EQUIPPED WITH BRACKETS DESIGNED FOR ATTACHING DIRECTLY TO THE STUDS OR SHALL BE MOUNTED ON HEAVY GAUGE GALVANIZED STEEL BOX SUPPORTS. 2. FIXTURE OUTLET BOXES INSTALLED IN SUSPENDED CEILINGS OF GYPSUM BOARD OR LATH AND PLASTER CONSTRUCTION SHALL BE MOUNTED TO 16 GAUGE METAL CHANNEL BARS ATTACHED TO MAIN CEILING RUNNERS. 3. FIXTURE OUTLET BOXES INSTALLED IN SUSPENDED CEILINGS SYSTEMS SUPPORTING ACOUSTICAL TILES OR PANELS SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURES ABOVE WHEREVER PENDANT - MOUNTED FIXTURES ARE INSTALLED FROM THE BOX. D. MOUNTING HEIGHTS: UNLESS NOTED OTHERWISE HEIGHTS ARE FROM FINISHED FLOOR TO CENTER LINE OF DEVICE BOX SHALL BE AS FOLLOWS, AND IN ACCORDANCE WITH HANDICAPPED ACCESSIBILITY REQUIREMENTS OF STATE CODE. DEVICE: HEIGHT(INCHES) CONVENIENCE RECEPTACLE & TELEPHONE OUTLET 18 CONVENIENCE RECEPTACLES ABOVE COUNTERS UNLESS OTHERWISE NOTED 44 SWITCHES, LIGHT 46 3.05 TRANSFORMER INSTALLATION A. TRANSFORMER SHALL BE FLOOR MOUNTED AS SHOWN ON THE DRAWINGS. PROVIDE MOUNTING HARDWARE TO SAFELY CARRY THE WEIGHT OF THE TRANSFORMER. MAINTAIN ADEQUATE SPACING FOR VENTILATION AS RECOMMENDED BY THE MANUFACTURER AND REQUIRED BY CODE. B. PROVIDE KORFUND TYPE VIBRATION ISOLATION PADS FOR EACH TRANSFORMER. C. CONNECTIONS TO TRANSFORMER SHALL BE MADE WITH FLEXIBLE METALLIC CONDUIT. INSTALL GROUND CONDUCTORS IN EACH CONDUIT AND PROVIDE GROUNDING BUSHINGS AS REQUIRED. D. PROVIDE HEAT INSULATING BARRIER BELOW TRANSFORMER WHERE INSTALLED ON COMBUSTIBLE SURFACE. END OF SECTION SECTION 16510: UGHIING FIXTURES 00./0".' PART 1 GENERAL 1.01 DESCRIPTION A. WORK INCLUDED 1. PROVIDE COMPLETE LIGHTING SYSTEM, WIRED, ASSEMBLED AND OPERABLE, INCLUDING LIGHTING FIXTURES, EQUIPMENT AND ACCESSORIES AS SHOWN ON THE DRAWINGS AND DESCRIBED IN THE FIXTURE SCHEDULES AS NECESSARY TO PROPERLY AND COMPLETELY INSTALL THE FIXTURES IN THE TYPE OF CEILINGS SHOWN ON THE ARCHITECTURAL REFLECTED CEILING PLANS AND SPECIFIED HEREIN. ACCESSORIES INCLUDE CANOPIES, SUSPENSION OF PROPER LENGTHS, HICKEYS, CASTINGS, SOCKETS, HOLDERS, REFLECTORS, BALLASTS, DIFFUSING MATERIAL, LOUVERS, PLASTER AND MOUNTING FRAMES, LAMPS, RECESSING BOXES, SUPPORTING BRACKETS AND CHANNELS TO SPAN STRUCTURAL MEMBERS. FIXTURES TO BE FACTORY PREWIRED AND PREASSEMBLED. 2. INSTALLATION AND CONNECTION OF ALL FIXTURES, LAMPS, BALLASTS, LIGHTING CONTROL DEVICES, RELAYS, RELATED COMPONENTS AND ACCESSORY WIRING AS SHOWN ON THE PLANS, FIXTURE SCHEDULE OR AS SPECIFIED HEREIN. 3. FINAL AIMING AND ADJUSTMENT OF RECESSED ADJUSTABLE FIXTURES AND TRACK MOUNTED FIXTURES SHALL BE BY THE ELECTRICAL CONTRACTOR, AS DIRECTED BY THE OWNER'S REPRESENTATIVE. B. RELATED WORK SPECIFIED ELSEWHERE: REFER TO SECTION 16050 FOR REQUIREMENTS APPLICABLE TO THIS SECTION. 1.02 COORDINATION: REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION OF LIGHTING FIXTURES. 1.03 SUBMITTALS: SUBMIT IN CONFORMANCE WITH THE REQUIREMENTS OF SECTION 16050: TIME SWITCHES, CONTROL DEVICES, RELAYS AND CABINETS AND WIRING DIAGRAMS. PRODUCTS LAMPS INCANDESCENT LAMPS: GENERAL PURPOSE A BASE LAMPS SHALL BE INSIDE FROSTED, RATED 120 VAC, OR AS NOTED ON FIXTURE SCHEDULE. REFLECTOR STYLE LAMPS, R AND PAR, AS NOTED ON FIXTURE SCHEDULE. MR16 LAMPS SHALL BE G.E. PRECISE CONSTANT COLOR TYPE. FLUORESCENT LAMPS 1. 24, 36 AND 48 INCH LONG LAMPS SHALL BE T8 ENERGY SAVING DELUXE WARM - WHITE, UON. 2. COMPACT TWIN -TUBE AND DOUBLE TWIN -TUBE, 9, 13 AND 18 WATTS NOMINAL, 735 K SPX35. C. LAMPS SHALL BE MANUFACTURED AS INDICATED IN THE LIGHTING FIXTURE SCHEDULE ONLY. 2.02 BALLASTS A. FLUORESCENT LAMP BALLASTS 1. BALLASTS SHALL COMPLY WILL ALL APPLICABLE UL AND ANSI STANDARDS AND SHALL BE UL LISTED. BALLASTS PERFORMANCE MAY BE CERTIFIED BY A NATIONALLY RECOGNIZED INDEPENDENT TESTING LABORATORY WITH A U.S. GOVERNMENT REGISTERED CERTIFICATION MARK FOR FLUORESCENT LAMP BALLASTS. PERFORMANCE CERTIFICATION SHALL BE CONDUCTED PER ETL IN ACCORDANCE WITH ANSI TEST METHODS. INTERIOR BALLASTS SHALL CONFORM TO THE STATE ENERGY STANDARDS. FLUORESCENT BALLASTS SHALL BE WARRANTIED AGAINST FAILURE DUE TO DEFECTS IN MATERIAL AND WORKMANSHIP FOR A MINIMUM PERIOD OF THREE (3) YEARS FROM DATE OF INSTALLATION ACCEPTANCE REGARDLESS OF THE DATE OF MANUFACTURE. BALLASTS SHALL BE CLASS P, SOUND RATED A, "FULL - OUTPUT' ENERGY - SAVING, ELECTRONIC BALLASTS FOR OCTRON LAMPS AS MANUFACTURED BY MAGNETEK. 2. BALLASTS FOR COMPACT FLUORESCENT LAMPS SHALL HAVE HIGH POWER FACTOR. 3. BALLASTS SHALL BE APPROVED FOR USE WITH ENERGY SAVING LAMPS BY THE LAMP MANUFACTURER. PART 2 2.01 A. B. 2.03 REFRACTORS, REFLECTORS AND LOUVERS (FURNISHED BY OWNER) A. ALL GLASSWARE, PLASTER AND METAL SHALL BE UNIFORM, FREE FROM DEFECTS, AND PHOTOMETRICALLY TESTED FOR DISTRIBUTION BY AN INDEPENDENT TESTING LABORATORY. B. PLASTIC DIFFUSERS SHALL BE OF VIRGIN ACRYLIC PLASTIC. C. POLISHED REFLECTORS USED WITH TRIPHOSPHOR COMPACT LAMPS SHALL HAVE ANTI- IRIDESCENT OPTICAL COATING. 2.04 UGHIING FIXTURES A. FIXTURES SHALL BE LISTED AND LABELED BY UNDERWRITERS LABORATORIES OR ETL TESTING LABORATORIES. LIGHTING FIXTURE MANUFACTURER'S CATALOG NUMBERS ARE INDICATIVE OF DESIRED DESIGN, APPEARANCE QUAILTY AND PERFORMANCE. OTHER FIXTURES OFFERING THESE SAME FEATURES MAY BE CONSIDERED AS SUBSTITUTIONS, ALTHOUGH THE FINAL ACCEPTANCE OF SUCH SUBSTITUTIONS ARE TO BE MADE BY THE ARCHITECT. ALL FIXTURES SHALL BE CERTIFIED FOR COMPLIANCE WITH THE STATE ENERGY COMMISSION. EXIT LIGHTS SHALL BE PROVIDED WITH MOUNTING AND DIRECTIONAL HARDWARE TO MEET FIELD CONDITIONS. VERIFY PRIOR TO ORDERING. PART 3 EXECUTION 3.01 INSTALLATION A. CONTRACTOR SHALL BE RESPONSIBLE FOR HANDLING AND STORAGE. FIXTURES SHALL BE INSTALLED PLUMB, LEVEL, IN STRAIGHT LINES WITHOUT DISTORTION AND CLEAN. B. INSTALL EACH FIXTURE IN A MANNER RECOMMENDED BY THE FIXTURE MANUFACTURER AND APPROVED BY THE OWNER'S REPRESENTATIVE. UNDER THIS SECTION OF THE WORK, FURNISH AND INSTALL ALL ADDITIONAL CEILING BRACING, HANGER SUPPORTS AND OTHER STRUCTURAL REINFORCEMENTS TO THE BUILDING REQUIRE TO PROPERLY AND SAFELY SUSPEND FIXTURES, ALL AS APPROVED BY THE OWNER'S REPRESENTATIVE. C. FIXTURES IN AREAS OF EXPOSED DUCT AND PIPE WORK SHALL BE SUSPENDED TO AVOID CONFLICT WITH SAME. D. PENDANT FIXTURES SHALL BE PROVIDED WITH BALL ALIGNERS AND SWAY ADAPTERS. FIXTURE CHAIN SHALL NOT BE USED FOR SUPPORTING FIXTURES. E. BALLASTS: BALLASTS JUDGED BY THE OWNER'S REPRESENTATIVE TO BE NOISY, AND FAILED OR MALFUNCTIONING BALLASTS SHALL BE REPLACED AT OWNER'S EXPENSE. B. C. 3.02 FIXTURE SUPPORT - SUSPENDED CEIUNGS A. ALL LIGHT FIXTURES INSTALLED IN SUSPENDED CEILINGS MUST BE FASTENED TO CEILING FRAMING MEMBERS PER NEC AND TO BUILDING STRUCTURE PER UBC. PROVIDE EARTHQUAKE CLIPS & SEISMIC SUPPORT BRACING AS REQUIRED. LIGHT FIXTURES INSTALLED IN AREAS WHERE THERE IS NO CEILING SHALL BE SUPPORTED FROM STRUCTURE ABOVE ONLY USING APPROVED SUPPORTS. END OF SECTION SECTION 16720: FIRE ALARM SYSTEM BIDDER DESIGN (NOT PART OF THIS PROJECT) PART 1 GENERAL 1.01 SCOPE OF WORK A. PROVIDE A COMPLETE BIDDER DESIGN FIRE ALARM SYSTEM FOR THE TENANT SPACE TO INCLUDE, BUT SHALL NOT BE LIMITED TO: 1. COMPLETE SYSTEM DESIGN. THIS SHALL INCLUDE COORDINATION OF LANDLORD AND JURISDICTIONAL REQUIREMENTS. 2. DEVELOP PERMIT SUBMITTAL DOCUMENTATION, INCLUDING SHOP DRAWINGS AND BATTERY CALCULATIONS. 3. ALL WORK, ITEMS, ARTICLES, MATERIALS, EQUIPMENT, WIRING, AND RACEWAY FOR A COMPLETE AND OPERATIONAL SYSTEM. 4. SYSTEM TESTING, DEMONSTRATION, AND TRAINING. 5. WARRANTY. 6. ALL DOCUMENTATION REQUIRED BY NFPA. B. SUBMITTALS - BIDDER DESIGN CONTRACTOR SHALL PROVIDE ALL SUBMITTALS AS FOLLOWS: 1. SHOP DRAWINGS AND PRODUCT DATA SHALL BE SUBMITTED TO ARCHITECT FOR APPROVAL OF DEVICE LOCATIONS AND FINISH. 2. SUBMIT ALL DOCUMENTATION TO LANDLORD AND LOCAL JURISDICTION AS REQUIRED FOR APPROVAL AND TO OBTAIN PERMITS. THIS SHALL INCLUDE, BUT IS NOT LIMITED TO, SHOP DRAWINGS, BATTERY CALCULATIONS. LISTING INFORMATION, AND PRODUCT DATA. 1.02 CODES AND STANDARDS A. TENANT SYSTEM SHALL BE IN ACCORDANCE WITH ALL JURISDICTIONAL CODES, AND SHALL BE IN COMPLIANCE WITH THE LANDLORD'S STANDARDS AND REQUIREMENTS. 1.03 APPROVED CONTRACTOR AND INSTALLER A. ALL WORK RELATED TO THE TENANT FIRE ALARM SYSTEM INSTALLATION SHALL BE PERFORMED BY A LANDLORD APPROVED CONTRACTOR. B. ALL WORK REQUIRED TO BE PERFORMED BY THE LANDLORD OR THE LANDLORD'S CONTRACTOR SHALL BE AT THE EXPENSE OF THE TENANT FIRE ALARM CONTRACTOR. 1.04 DEVICE COORDINATION A. FIRE ALARM SYSTEM DEVICES, NOTES, AND RELATED INFORMATION SHOWN ON THE ELECTRICAL PLANS ILLUSTRATES THE INTENT OF DEVICE LOCATIONS AND INSTALLATION REQUIREMENTS, AND SHALL NOT CONSTITUTE A COMPLETE FIRE ALARM SYSTEM DESIGN. BIDDER DESIGN CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE EXACT SYSTEM REQUIREMENTS WITH LANDLORD AND JURISDICTION. B. FIRE ALARM SYSTEM INSTALLER SHALL COORDINATE WITH ARCHITECTURAL AND ALL OTHER TRADES FOR PROPER PLACEMENT OF DEVICES TO ELIMINATE CONFLICTS WITH OTHER SYSTEMS. PART 2 PRODUCTS 1.01 DEVICES AND EQUIPMENT A. ALL WIRING, DEVICES, AND EQUIPMENT SHALL BE NEW AND COMPATIBLE WITH LANDLORD'S SYSTEM. B. ALL DEVICES AND EQUIPMENT SHALL BE U.L. LISTED, FM APPROVED, AND LABELED FOR FIRE ALARM SYSTEM USE. AUDIBLE /VISUAL DEVICES, IF REQUIRED, SHALL BE WHITE IN COLOR AND CEILING MOUNTED, UNLESS NOT ALLOWED BY LANDLORD OR JURISDICTION. IF CEIUNG MOUNT DEVICE ARE NOT ALLOWED BY JURISDICTION OR LANDLORD, PROVIDE THE REQUIRED WALL MOUNT DEVICES. D. PULL STATIONS, IF REQUIRED, SHALL BE FLUSH. E. FOR INSTALLATIONS REQUIRING COMMUNICATOR OR DIALER, PROVIDE REQUIRED PRIMARY AND SECONDARY TELEPHONE LINES TO CONTROL PANEL AND PROVIDE 120 VAC DEDICATED BRANCH CIRCUIT AS REQUIRED FOR POWER. INSTALLATION ? REVJ CODE ( C. PART 3 1.01 1.02 INSTALLATION SHALL BE IN COMPUANCE WITH LANDLORD AND JURISDICTIONAL REQUIREMENTS. INSTALLATION SHALL BE IN ACCORDANCE WITH REQUIREMENTS OUTLINED IN TENANT DESIGN MANUAL 1.03 WIRING A. AT AREAS THAT ARE WITHIN PUBLIC VIEW, ALL FIRE ALARM CABLING SHALL BE RUN IN EMT. B. AT NON -PUBUC AREAS, CABLING MAY BE RUN EXPOSED ABOVE 10' A.F.F. UNLESS ' Ciyi LANDLORD /JURISDICTION REQUIRES METALUC RACEWAY. IF S0, PROVIDE REQUIRED RACEWAY. Y 0 CABUNG BELOW 10' A.F.F., RUN CONCEALED IN WALL OR IN RACEWAY. �U® 1.04 CEIUNG MOUNT DEVICES A. AT AREAS WITH GWB OR ACT CEILING, PROVIDE REQUIRED BACKBOX AND FLUSH MOUNT DEVICE IN CEILING. B. AT AREAS OPEN TO STRUCTURE, PROVIDE APPROPRIATE BACKBOX ATTACHED TO STRUCTURE WITH SURFACE MOUNT DEVICE. FOR AUDIBLE /VISUAL DEVICE SUPPORT FROM STRUCTURE WITH 3/8" THREADED ROD WITH DEVICE AT THE REQUIRED ELEVATION. 1.05 COORDINATION A. PRIOR TO INSTALLATION, INSTALLER SHALL REVIEW WITH THE LOCAL JURISDICTION AND THE LANDLORD, THE FIRE ALARM SYSTEM DEVICE LOCATIONS. INSTALLATION SHALL NOT OCCUR UNTIL APPROVAL OF LAYOUT IS OBTAINED BY BOTH AGENCIES AND COORDINATED WITH ARCHITECT. B. IF CEILING MOUNTED AUDIBLE /VISUAL DEVICES ARE NOT ALLOWED BY THE LOCAL JURISDICTION, NOTIFY ARCHITECT. 1.06 FIRE ALARM SYSTEM BIDDER DESIGN CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL RACEWAY REQUIRED FOR THE FIRE ALARM SYSTEM INSTALLATION. PART 4 TESTING AND CLOSEOUT 1.01 PROVIDE A COMPLETE SYSTEM TEST AS REQUIRED BY NFPA 72, AND THE LANDLORD. 1.02 TEST ALL CONDUCTORS AS REQUIRED IN NFPA 72, CHAPTER 7 AND COMPLETE THE INSPECTION AND TESTING FORM IN NFPA 72, FIGURE 7- 5.2.2. 1.03 SUBMIT ALL IESIING AND INSPECTION REPORTS, SHOP DRAWINGS, AND AS -BUILT DRAWINGS TO OWNER AND AUTHORITY HAVING JURISDICTION AS REQUIRED BY NFPA 72. 1ERIA" FPS JUL COPYRIGHT 0 2008 CARTER & BURGESS, INC. at &t Carter::Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 07 -16 -08 EXPIRES 08/26/09 ISSUES /REVISIONS CITY OF TUKW1LA .1I H. 18 2008 PER dIT CENTER 1 03 -29 -08 TENANT CHANGES NO. 03 -19 -08 ISSUE FOR PERMIT DATE DESCRIPTION 16425 Southcenter Parkway T U KW I LA, WA EV/ED FOR ;OMPLIANCE 70 - NEC 2 9 20 )f Tukwila IMION DRAWN en RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: 441805.011.028.0001 NONE ELECTRICAL SPECIFICATIONS E -004 R:\JOB \Cingular \Washington State \16425 Southcenter -See's Candy, WA \SheetE- 101.dwg, 7/17/2008 1:39:58 PM, MAGUIReMJ B B (2) B (TOP & BOTTOM) 26e B2 26e B2 26e 26e C1 0 30g0 C GENERAL NOTES: 1. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHTING FIXTURES, UGHTING FIXTURE MOUNTING HEIGHT, LIGHTING FIXTURE SCHEDULE AND OTHER DETAILS ON LIGHTING REQUIREMENTS. 2. FIELD VERIFY FOR EXISTING ELECTRICAL PANEL AND LIGHTING CONTROL EQUIPMENT LOCATION. MAKE ADJUSTMENTS AS REQUIRED. 3. SEE ARCHITECTURAL DRAWINGS FOR AREA OF ELECTRICAL DEMOLITION WORK. REMOVE / RELOCATE ALL ELECTRICAL EQUIPMENT, LIGHTING FIXTURES, DEVICES AND ASSOCIATED CONDUIT AND WIRE THAT INTERFERE WITH NEW CONSTRUCTION. DISPOSE OF DEMOLISHED EQUIPMENT AS DIRECTED BY OWNER. MAINTAIN POWER CONNECTION TO EXISTING EQUIPMENT AND LIGHTING FIXTURES TO REMAIN. 4. PROVIDE A TIME CLOCK, CONTACTOR PANEL MANUAL OVERRIDE SWITCH AND ALL ASSOCIATED EQUIPMENT AND WIRING AS REQUIRED FOR AUTOMATIC LIGHTING SHUT -OFF AFTER HOURS. SEE TYPICAL LIGHTING CONTROL DETAIL ON SHEET E -103. 5. FIELD COORDINATE FOR ALL NEW ELECTRICAL EQUIPMENT LOCATION. MAKE PROPER ADJUSTMENTS. 6. SEE PANEL SCHEDULES AND SINGLE LINE DIAGRAM ON SHEET E -103 FOR REFERENCE TO CIRCUITING REQUIREMENTS. ROUTE ALL LIGHTING CIRCUITS VIA LIGHTING CONTACTOR PANEL. PROVIDE UNSWITCHED HOT TO EMERGENCY EXIT SIGNS AND EMERGENCY LIGHTING FIXTURES. 7. FIELD VERIFY THAT EMERGENCY UGHTING FIXTURES PROVIDE 1 FOOT- CANDLE MINIMUM AT FLOOR LEVEL. ADD EMERGENCY LIGHTS AS REQUIRED. 8. LIGHTING FIXTURES SHOWN SHADED ARE NIGHT LIGHTS AND MUST ALWAYS STAY ON. PROVIDE INTEGRAL 90 MINUTES EMERGENCY POWER BATTERY AND UNSWITCHED POWER CONNECTION AS SHOWN. 9. LIGHTING FIXTURES TYPE "B ", "B1" AND "B2" (SHOWN DASHED) ARE PROVIDED WITH FURNITURE_ AND ARE MOUNTED ON THAT FURNITURE. ELECTRICAL CONTRACTOR SHALL PROVIDE SWITCHED RECEPTACLE AS SHOWN FOR PROPER POWER AND CONTROL CONNECTION. FIELD VERIFY FOR EXACT REQUIREMENTS PRIOR TO ROUGH -IN. 10. PROVIDE #10 CONDUCTORS IN CONDUITS WITH MORE THAN (6) SIX CURRENT - CARRYING CONDUCTORS, UNO. PLAN NOTES: 0 PROVIDE MANUAL MOTOR RATED TOGGLE SWITCH AND POWER CONNECTION TO RESTROOM EXHAUST FAN AS SHOWN. EXHAUST FAN SHALL BE CONTROLLED BY THE RESTROOM LIGHTING SWITCH. 02 PROVIDE NEW SWITCHBANK TO CONTROL SALES FLOOR LIGHTING CIRCUITS. COORDINATE WITH THE OWNER FOR LIGHTING SWITCH LOCATIONS. ADJUST AS REQUIRED. PROVIDE ONE SINGLE POLE SWITCH FOR EACH CIRCUIT. MOUNT ALL SWITCHES IN GANGED WALL BOX WITH SINGLE COVERPLATE. PROVIDE ENGRAVED DESCRIPTION AT EACH SWITCH - "TRACK LTS ", WALL UNIT LTS ", ETC. @ PROVIDE 2'X4' FLUORESCENT FIXTURE WM-I T8 LAMPS AND ELECTRONIC BALLAST. FIXTURE TYPE SHALL BE SUITABLE FOR INSTALLATION IN CEILING TYPE SPECIFIED ON ARCHITECTURAL DRAWINGS. TYPICAL. ® PROVIDE EMERGENCY LIGHT FIXTURE AND LED EXIT SIGN AS SHOWN. PROVIDE UNSWITCHED CIRCUIT. TYPICAL. 0 PROVIDE 20A, 125V LIGHTING SWITCH AS SHOWN. TYPICAL. ® PROVIDE MANUAL OVERRIDE SWITCH. FIELD VERIFY FOR LOCATION AND PROPER OPERATION. MAKE ADJUSTMENTS AS REQUIRED. COORDINATE LOCATION WITH OWNER. 0 LIGHTING FIXTURE "B2" AND ASSOCIATED CORD AND PLUG ARE BEING PROVIDED AS PART OF THE WALL UNIT. PROVIDE OUTLET 26" AFF, BEHIND THE WALL UNIT, WITHIN 6" OF THE END. THE OUTLET SHALL BE SWITCHED AS SHOWN. ANOTHER UNSWITCHED OUTLET SHALL BE PROVIDED FOR POWER CONNECTION TO PHONES AND ACCESSORIES. SEE SHEET E -102 FOR DETAILS. TYPICAL FOR WALL UNIT FIXTURES. FIELD COORDINATE PRIOR TO ROUGH -IN. PROVIDE FLOOR OUTLET WHERE WALL UNIT INSTALLED AT GLASS WALL AND WALL OUTLET INSTALLATION IS IMPOSSIBLE. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUL 9 2008 City Of Tukwila B_IIDIN.G „IIIISION RECEIVED CITY OF TUKWILA JUL 18 2008 PERMIT CENTER ELECTRICAL LIGHTING PLAN SCALE: 1/4"=1P-0” 1 COPYRIGHT 0 2008 CARTER & BURGESS. INC. at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 EXPIRES 08/26/09 ISSUES /REVISIONS 3 07 -16 -08 TENANT CHANGES 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TUKWILA, WA NORTH DRAWN BY: RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: ELECTRICAL LIGHTING PLAN E 441805.011.028.0001 AS SHOWN 101 R: \JOB \Cingular\Washington State \16425 Southcenter -See's Candy, WA \Sheet \E- 102.dwg, 7/17/2008 1:40:10 PM, MAGUIReMJ LOCATE OUTLET 26" AFF, BEHIND THE WALL UNIT, WITHIN 6" OF THE END. ANOTHER SWITCHED POWER OUTLET SHALL BE PROVIDED FOR POWER CONNECTION TO WALL UNIT LIGHTING FIXTURE. SEE SHEET E -101 FOR DETAILS. TYPICAL FOR WALL UNIT RECEPTACLES. PROVIDE FLOOR OUTLET WHERE WALL UNIT INSTALLED AT GLASS WALL AND WALL OUTLET INSTALLATION IS IMPOSSIBLE DEDICATED PRINTER CIRCUIT. MOUNT OUTLETS +20 "AFF — "C "- 14,16,18 "C "- 8,10,12 +45" AFF v - ' T, 3/4"C -2 18 & 118 GND DOWN TO PANEL "B" -8,10 ABOVE CEILING i:ataas21!.am21' "B" -34,36 25 DEDICATED PRINTER CIRCUIT. MOUNT OUTLETS +20 "AFF - 1- 1/4 "C -3 14 & 1 #8 GND DOWN TO PANEL "B" -2,4,6 DEDICATED PRINTER CIRCUIT. MOU NT OUTLETS +26 "AFF 4" WIREMOLD FOR PERIMETER POWER, TYPICAL. SEE DETAIL C7 /A -802 GENERAL NOTES: 1. SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND MOUNTING HEIGHT OF DEVICES AND OTHER DETAILS ON POWER AND COMMUNICATIONS CONNECTIONS. 2. FIELD VERIFY FOR EXISTING ELECTRICAL AND TELEPHONE SERVICE LOCATION. 3. SEE MECHANICAL AND PLUMBING DRAWINGS FOR EXACT LOCATION OF MECHANICAL / PLUMBING EQUIPMENT, RELATED DEVICES AND EQUIPMENT CONTROLS. COORDINATE WITH MECHANICAL / PLUMBING CONTRACTOR FOR POWER AND CONTROL CONNECTION REQUIREMENTS PRIOR TO ROUGH -IN. ALL CONTROL CONDUITS ARE BY ELECTRICAL CONTRACTOR. CONTROL WIRING IS BY MECHANICAL CONTRACTOR. COORDINATE CIRCUIT SIZES, DISCONNECTS AND TERMINATION LOCATIONS WITH MECHANICAL CONTRACTOR BEFORE ROUGH -IN. 4. PROVIDE 120VAC POWER CONNECTION TO DUCT SMOKE DETECTORS. SEE MECHANICAL DRAWINGS FOR DETAILS. 5. SEE ARCHITECTURAL DRAWINGS FOR AREA OF ELECTRICAL DEMOLITION WORK. FIELD VERIFY AND REMOVE / RELOCATE ALL DEVICES AND EQUIPMENT THAT INTERFERE WITH NEW CONSTRUCTION. REMOVE ASSOCIATED CONDUIT AND WIRE BACK TO THE LAST ACTIVE DEVICE OR BACK TO PANEL AS REQUIRED. MAINTAIN POWER CONNECTION TO EXISTING DEVICES TO REMAIN. 6. SEE PANEL SCHEDULES AND SINGLE UNE DIAGRAM ON SHEET E -103 FOR REFERENCE TO CIRCUCTING REQUIREMENTS. 7. PROVIDE COMPLETE CONDUIT SYSTEM FOR POWER AND CONTROL CONNECTIONS TO ALL MECHANICAL, SECURITY, FIRE ALARM AND OTHER DEVICES AND EQUIPMENT SHOWN ON ELECTRICAL, ARCHITECTURAL, MECHANICAL, PLUMBING, FIRE ALARM AND OTHER DRAWINGS. FIELD COORDINATE FOR EXACT REQUIREMENTS. 120V AND UP WIRING IS BY ELECTRICAL CONTRACTOR. LOWER VOLTAGE WIRING IS BY OTHERS, U.N.O. 8. EQUIPMENT, DEVICES, CONDUIT AND WIRE SHOWN ON THIS PLAN ARE NEW, UNLESS NOTED OTHERWISE. 9. PROVIDE CORES, PATCH AND PAINT TO MATCH EXISTING CONDITIONS. 10. MOUNT NEW DEVICES FLUSH IN WALLS. PATCH AND PAINT TO MATCH EXISTING CONDITIONS. 11. ELECTRICAL EQUIPMENT AND DEVICES OUTSIDE AND ON THE ROOF SHALL BE WEATHER PROOF. 12. RECEPTACLES ON ROOF SHALL BE SURFACE MOUNTED WEATHERPROOF AND GA WITH "TAYMAC" ENCLOSURE OR APPROVED EQUAL TO MEET NEC 410.57b. PROVIDE UNISTRUT SUPPORT AS REQUIRED. MOUNT WEATHERPROOF /GFI RECEPTACLE AT EACH HVAC UNIT. 13. CONDUIT PENETRATIONS SHALL BE THROUGH MECHANICAL EQUIPMENT CURBS, NO INDIVIDUAL CONDUIT ROOF JACKS. CAULK AROUND THE CONDUITS FOR WEATHER PROOF AT POINT OF ENTRY TO THE ROOF. TYPICAL FOR ALL CONDUITS PENETRATING THE ROOF. 14. PROVIDE BOXES, POWER AND COMMUNICATIONS OUTLETS, CONDUIT AND WIRE AT CASHWRAPS AS REQUIRED PER FIELD CONDmONS. ALL ELECTRICAL WORK INCLUDING BUT NOT LIMITED TO INSTALLATION AND WIRING OF OUTLETS IN THE MILLWORK SHALL BE DONE BY ELECTRICAL CONTRACTOR. PLAN NOTES: O RECEPTACLES AND COMMUNICATION OUTLETS SHALL BE MOUNTED IN CASHWRAP BY ELECTRICAL CONTRACTOR. RECEPTACLES SHALL BE WIRED TO A JUNCTION BOX WITHIN CASHWRAP. PROVIDE BRANCH CONNECTION TO JUNCTION BOX AND ENERGIZE RECEPTACLES. SEE DETAIL N0.3, SHEET E -104. ® PROVIDE RECEPTACLE IN WIREMOLD AT UNDERSIDE OF CASHWRAP COUNTER FOR POWERING LAMP MOUNTED ON UPRIGHT. SEE DETAIL N0.2, SHEET E -104. 03 ROUTE BRANCH CIRCUIT FROM ABOVE CEILING, DOWN CASHWRAP UPRIGHT SUPPORT TO POWER DEVICES INDICATED. SEE DETAIL N0.3, SHEET E -104. ® PROVIDE DEDICATED OUTLETS FOR POWER AND COMMUNICATIONS CONNECTION TO STORE EQUIPMENT AS SHOWN. SEE ARCHITECTURAL DRAWINGS FOR DETAILS. FIELD COORDINATE. ® FIELD VERIFY FOR POWER AND COMMUNICATION OUTLETS IN NEW ROOM. PROVIDE AS REQUIRED. © PROVIDE BACKBOX AND 1/2" C.O. FROM THE THERMOSTAT BY MECHANICAL CONTRACTOR TO CORRESPONDING AC UNIT ON ROOF. CONTROL WIRING IS BY MECHANICAL CONTRACTOR. COORDINATE WITH MECHANICAL CONTRACTOR FOR THERMOSTAT LOCATION AND CONTROL CONDUIT CONNECTION DETAILS. ® PROVIDE 3/4 "x6'x8' FIRE TREATED PLYWOOD TELEPHONE BACKBOARD. PROVIDE THREE (3) QUAD RECEPTACLES ON DEDICATED CIRCUITS. MOUNT ONE RECEPTACLE AT THE TOP, ANOTHER TWO AT THE BOTTOM. PROVIDE 1 -1/2" C.O. FROM BUILDING TELECOM SERVICE TO NEW TELEPHONE BACKBOARD. HELD COORDINATE CONDUIT ROUTING. SEE ARCHITECTURAL DRAWINGS FOR TELEPHONE / DATA SYSTEM REQUIREMENTS. PROVIDE WALL MOUNTED RACK 48" HIGH, 24" DEEP, 19" WIDE, SWING OUT, WITH MINIMUM 150 LB CAPACITY. ® DISCONNECT AND REMOVE EXISTING FEEDERS AND BRANCH CIRCUITS FROM EXISTING ELECTRICAL EQUIPMENT LOCATED IN EXISTING ELECTRICAL ROOM BEING DEMOLISHED. NOTE EXISTING POWER CONNECTION TO ELECTRICAL LOADS TO REMAIN. REMOVE EXISTING ELECTRICAL PANELS, EXISTING DISTRIBUTION BOARD AND EXISTING METERING EQUIPMENT LOCATED IN A CABINET ON EXTERIOR WALL. PROVIDE ELECTRICAL SERVICE EQUIPMENT, ELECTRICAL PANELS AND CORRESPONDING FEEDERS AS SHOWN ON SINGLE LINE DIAGRAM, SHEET E -103. FIELD COORDINATE PRIOR TO ROUGH -IN. SEE SHEET E -103 FOR DETAILS. MAINTAIN 3' CLEARANCE IN FRONT OF ELECTRICAL EQUIPMENT. ® PROVIDE POWER CONNECTION TO STORE SIGNAGE. SIGNAGE CIRCUIT SHALL BE CONTROLLED BY THE TIME CLOCK. FIELD COORDINATE FOR SIGNAGE LOCATION AND POWER / CONTROL REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE A 120V, 20A TOGGLE SWITCH AS A LOCAL DISCONNECT. 10 PROVIDE POWER CONNECTION TO UNIT CONTROL PANEL AS SHOWN. EQUIPMENT LOCATION ON ROOF (AND ABOVE CEILING) AND DEVICE SIZES ARE SHOWN FOR REFERENCE ONLY. FIELD VERIFY. PROVIDE HEAVY DUTY, FUSED DISCONNECT SWITCH. VERIFY DISCONNECT SWITCH AND FUSE SIZES WITH UNIT MANUFACTURER'S NAMEPLATE DATA PRIOR TO ORDERING. PROVIDE TYPE RK5 FUSES. DISCONNECT SWITCH AT UNIT SHALL BE LOCATED SO AS NOT TO OBSTRUCT UNIT NAMEPLATE OR ACCESS PANELS. WIRING TO PANEL AND CIRCUIT BREAKER SIZES SHALL MATCH UNIT INSTALLATION MANUAL REQUIREMENTS. PRIOR TO ROUGH -IN FIELD VERIFY FOR REQUIRED PANEL VOLTAGE, CIRCUIT BREAKER SIZE, CONDUCTORS SIZE, DISCONNECT SWITCH FUSE SIZE, ETC. MAKE PROPER ADJUSTMENTS. PROVIDE POWER CONNECTION TO ASSOCIATED DEVICES AS SHOWN. 11 PROVIDE POWER CONNECTION TO WATER HEATER. PROVIDE A HEAVY DUTY TOGGLE SWITCH AS A LOCAL DISCONNECT (MOTOR RATED SWITCH - 3HP MINIMUM, 1 PHASE, NON- FUSED) BY SQUARE -D OR EQUAL. COORDINATE WITH WATER HEATER INSTALLER PRIOR TO ROUGH -IN. @ PROVIDE FLUSH FLOOR MOUNTED POWER / COMMUNICATIONS OUTLETS AS SHOWN. PROVIDE WIREMOLD #881 RC4ATCBK FLOOR BOX WITH CORRESPONDING ACCESSORIES AS REQUIRED PER FIELD CONDITIONS. RUN COMMUNICATIONS CONDUIT AND POWER CONDUIT & WIRE UNDERFLOOR TO THE NEAREST WALL, THEN UP TO CEILING SPACE. EXTEND POWER CONDUIT AND WIRE TO ELECTRICAL PANEL AS SHOWN. EXTEND COMMUNICATION CONDUIT TO THE TELEPHONE BOARD IN INVENTORY ROOM. SEE ARCHITECTURAL DRAWINGS AND FIELD COORDINATE FOR OUTLET LOCATION PRIOR TO SAW CUTTING THE FLOOR. UNDERFLOOR CONDUIT ROUTING MAY BE ADJUSTED PER FIELD CONDmONS. FIELD COORDINATE PRIOR TO ROUGH -IN. PROVIDE BLACK COVER FOR CARPET FLOORING AND BRASS COVER FOR WOOD FLOORING. ELECTRICAL POWER & COMMUNICATIONS PLAN SCALE: 1/4"=1'—o" 1 COPYRIGHT 0 2008 CARTER & BURGESS. INC. at &t Carter:Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 EXPIRES 08/26/09 ISSUES /REVISIONS (RECEIVED v nF TUKWILA ."I 2008 )`- P111;1 r CENTER 3 07 -16 -08 TENANT CHANGES 2 04 -17 -08 REVISED ELECTRICAL SERVICE 1 03 -29 -08 TENANT CHANGES - 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TUKWILA, WA NORTH DRAWN BY: RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: 441805.011.028.0001 AS SHOWN ELECTRICAL POWER AND COMMUNICATIONS PLAN E 102 R: \JOB \Cingular \Washington State \16425 SouthcenterSee's Candy, WA1Sheet \E- 103.dwg, 7!1712008 1:40:24 PM, MAGUIReMJ COPYRIGHT 0 2008 CAREER & BURGESS, INC. at &t Carter::Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 EXPIRES 08/26/09 ISSUES /REVISIONS 3 07 -16 -08 TENANT CHANGES 2 04 -17 -08 REVISED ELECTRICAL SERVICE 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TU KW I LA, WA DRAWN BY: RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: 441805.011.028.0001 AS SHOWN ELECTRICAL PANEL SCHEDULES, DETAILS AND SINGLE LINE DIAGRAM E 103 N EXISTING UTILITY CO. GENERAL O TE S 2-CHANNEL 365 DAY / HOLIDAY PROGRAMMABLE DIGITAL TIME CLOCK IN A NEMA 1 ENCLOSURE. ( INTERMATIC ET70000C SERIES OR APPROVED INTERIOR LIGHTING CONTACTOR CONTROL EQUAL). PANEL, IN NEMA 1 ENCLOSURE. PROVIDE 0 SERVICE FEEDER TRANSFORMER 1. SINGLE LINE DIAGRAM IS SHOWN POLES AS REQUIRED, REFER TO PANEL r I J--' 1 ( SCHEDULES. PROVIDE MINIMUM 1 SPARE FOR REFERENCE ONLY. CONTRACTOR SHALL FIELD VERIFY THAT THE AMPACITY OF THE SERVICE DISCONNECT AND FEEDER ARE THE OF L. I 3 ii1 1 T_1 H I I L co H co co H co co H co H co 0 H co co H II 0.1 H I 9 H CO sI H CO Vi H I I I J METER & MAIN NEMA 3R O2 M O MAIN CB ) 400A 3P THE PANELBOARD 2. INSPECT AND RE- TORQUE EXISTING PANELBOARD FEEDER AND BUS TERMINATIONS PER MANUFACTURER'S REQUIREMENTS. 3. FIELD VERIFY AVAILABLE FAULT SEE GENERAL CURRENT AT SERVICE ENTRANCE NOTE 4 WITH UTILITY COMPANY PRIOR TO PROCUREMENT OF ELECTRICAL /^� DISTRIBUTION EQUIPMENT, AND I L 1 0 -2 -HOUR MANUAL OVERRIDE TIMER SWITCH (INTERMATIC #FF2H OR CIRC. APPROVED EQUAL) N A -16 I' N CIRC. A -18 N CIRC. A -20 N CIRC. A -22 N CIRC. A -24 N CIRC. A -26 N CIRC. A -28 N CIRC. A -30 ..- "HOT" N CIRC. A -32 ir N CIRC. A -34 �' GND BUS 0 PROVIDE (2)2- 1/2 "C, EACH WITH 4 #3/0 Sc 1#3 GND /L` VERIFY MINIMUM FAULT INTERRUPTING RATINGS OF TENANT — ELECTRICAL EQUIPMENT. 4. ELECTRICAL EQUIPMENT SHALL BE BONDED AND GROUNDED AS REQUIRED PER APPLICABLE CODES AND JURISDICTIONS. ELECTRICAL EQUIPMENT SHALL BE FULLY RATED FOR THE MAXIMUM AVAILABLE SHORT EQUIPMENT SHALL BE LISTED FOR jz-. 2- 1/2 "C -4 #3/0 Sc 1 #6 GND 0 CIRCUIT CURRENT. ELECTRICAL CONTINUOUS OPERATION AT 100% RATING. UNSWITCHED LIGHT FIXTURES "HOT" TO NIGHT AND EMERGENCY LIGHTING UNSWITCHED TO NIGHT LIGHT AND EMERGENCY LIGHTING FIXTURES • r 1 I I L N H co co H co co H CO /I H _ /I I _ J OF ITS O3 MAIN CB 200A 3P 0 MAIN CB ) 200A I 3P ♦ 5. FIELD VERIFY FOR ELECTRICAL EQUIPMENT AND ASSOCIATED CONDUITS AND WIRE TO BE REMOVED. PROVIDE DEMOLITION AS REQUIRED PER FIELD CONDITIONS. 6. EXISTING ELECTRICAL EQUIPMENT AND CONDUITS MAY BE REUSED IF DEEMED SUITABLE BY THE CIRC. A -14 SIGNAGE CONTACTOR CONTROL PANEL, IN NEMA 1 ENCLOSURE. PROVIDE POLES AS REQUIRED, REFER TO PANEL SCHEDULES. PROVIDE MINIMUM 1 SPARE N CIRC. A -38 N CIRC. A -40 N CIRC. A -42 N SPARE PANEL "A" at&t STORE PANEL T)60A "B" at&t STORE 3P O O3 CONTRACTOR. KEY NOTES: TYPICAL LIGHTING CONTROL DIAGRAM SCALE: NONE SUB -PANEL "c" at&t STORE PROVIDE DOUBLE LUGS 0 PROVIDE ELECTRICAL SERVICE CONDUIT(S) AND CONDUCTORS AS REQUESTED BY ELECTRICAL UTILITY COMPANY. FIELD VERIFY FOR REQUIREMENTS PRIOR TO ROUGH -IN. FEEDER LOAD SCHEDULE AND CALCULATIONS 400 AMP, 208/120V 3PHASE, 4 -WIRE & GND. LOAD COPPER FEEDERS VOLTAGE DROP CALCULATIONS AFC CALCULATIONS 0 REMOVE EXISTING ELECTRICAL SERVICE EQUIPMENT FROM THE 0 1- 1/4 "C -4 #4 & 1 #8 GND CABINET OUTSIDE. PROVIDE ELECTRICAL SERVICE EQUIPMENT AS SHOWN AND AS REQUIRED BY THE LOCAL ELECTRICAL UTILITY COMPANY. FIELD COORDINATE PRIOR TO ROUGH -IN. 03 PROVIDE ELECTRICAL PANELS AND CORRESPONDING FEEDERS AS SHOWN ON SINGLE LINE DIAGRAM AND PANEL SCHEDULES BELOW. SEE SHEET E -102 FOR MORE INFORMATION. NAME VOLTS 0 CONNECTED DEMAND CONDUITS WIRE PER CONDUIT GND.PER CONDUIT EST. DIST. REMARKS FEEDER SEGMENT DROP ONLY NET DROP AT DEVICE AFC FROM MOTOR CONTRI- BU11ON NET AFC AT DEVICE HP KVA KVA AMPS # SIZE # SIZE SIZE VOLTS DROP % VOLTS DROP % SOURCE UTILITY XFMR SECONDARY 208 3 98 111 308 65,000 107 65,107 MAIN SERVICE 208 3 98 111 308 2 2 1/2" 4 3/0 #3 80 2.00 0.96% 2.00 0.96% 65,107 24,216 PANEL "A" 208 3 48 56 157 1 2 1/2" 4 3/0 #6 20 0.51 0.25% 2.51 1.21% 24,216 18,429 PANEL "B" 208 3 50 54 151 1 2 1/2" 4 3/0 #6 20 0.49 0.24% 2.50 t20% 24,216 18,429 SUB -PANEL "C" 208 3 23 1 1 1/4" 4 #4 #8 10 0.12 0.06% 2.64 1.27% 18,429 13,133 VOLTAGE DROP CALCULATED USING CEC CHAPTER 9, TABLE 9. FEEDER LENGTHS ESTIMATED FOR CALCS ONLY, NOT FOR BIDDING. FAULT VALUES BASED ON POINT TO POINT METHOD. SINGLE LINE DIAGRAM SCALE: SCALE: 4 •� -�' , ELECTRICAL CALCULATIONS NONE NONE GENERAL NOTES. • PANELBOARD 'B' PANELBOARD 'A' 1. 2. 3. 4. 5. 6. MAIN: 120/208 VOLT / 3 PHASE / 4 WIRE MAIN BREAKER: 200 AMP MOUNTING: SURFACE BUS: 1 SECTION: SINGLE LUGS NEMA ENCLOSURE 1 BUS: 200 AMP A.I.C. RATING: 22K MAIN: 120/208 VOLT/ 3 PHASE / 4 WIRE MAIN BREAKER: 200 AMP MOUNTING: SURFACE BUS: 1 SECTION: DOUBLE LUGS NEMA ENCLOSURE 1 BUS: 200 AMP A.I.C. RATING: 22K PROVIDE ELECTRICAL PANELS AS SHOWN ON SINGLE LINE DIAGRAM AND PANEL SCHEDULES THIS SHEET. PROVIDE TYPED PANEL SCHEDULES. ADJUST CIRCUITING ON PANEL TO MAINTAIN 10% PHASE IMBALANCE MAXIMUM. SEE LIGHTING PLAN ON SHEET E -101 AND DETAIL THIS SHEET FOR LIGHTING CONTROL SYSTEM REQUIREMENTS. ROUTE ALL LIGHTING CIRCUITS VIA LIGHTING CONTACTOR. PROVIDE SWITCH RATED CIRCUIT BREAKERS FOR CIRCUITS SUPPLYING EMERGENCY LIGHTING FIXTURES. PROVIDE HACR TYPE CIRCUIT BREAKER FOR CIRCUITS SUPPLYING HVAC UNITS. FIELD VERIFY AND COORDINATE WITH MECHANICAL CONTRACTOR FOR POWER CONNECTION REQUIREMENTS TO HVAC EQUIPMENT, WATER HEATERS, EXHAST FANS, ETC. VERIFY REQUIRED CIRCUIT BREAKER SIZE AND CORRESPONDING CONDUIT & WIRE SIZES PRIOR TO ROUGH -IN. SEE SHEET E -102 FOR MORE INFORMATION. MAKE PROPER CORRECTIONS TO PANEL SCHEDULE IF REQUIRED. RECEIVED CITY OF TUKWIL.A JUL 18 2008 PERMIT CENTER LOAD VA LOAD DESCRIPTION OUTLETS CB / P It Y 0 w Q a 44 0 CB / P OUTLETS LOAD VA LOAD VA LOAD DESCRIPTION OUTLETS u Y 0 w Q a n Y 0 OUTLETS LOAD DESCRIPTION LOAD VA M R L L R M LOAD DESCRIPTION M R L CB / P CB / P L R M 360 CASH WRAP RECEPTACLES 2 20/1 1 A 2 60/3 1 RTU -1 6000 500 DRINKING FOUNTAIN 1 2011 1 A 2 20/1 2 TELEPHONE BOARD RECEPT. 1500 720 CASH REGISTER RECEPTACLES 4 20/1 3 B 4 - --- ----------------------- ---- -------- - - - - -- 6000 360 RESTROOM RECEPT. 2 20/1 3 B 4 20/1 2 TELEPHONE BOARD RECEPT. 1500 720 CASH REGISTER RECEPTACLES 4 20/1 5 C 6 - - -- ------------ -- -------------------- - - - - - -- 6000 2080 INSTAHOT 1 30/2 5 C 6 20/1 2 TELEPHONE BOARD RECEPT. 1500 r PANELBOARD 'C' 360 CASH WRAP RECEPTACLES 2 20/1 7 A 8 30/2 1 FC -1 2900 2080 - - - - - - - - - -- 7 A 8 2011 5 BACK AREA RECEPTACLES 900 720 CASH REGISTER RECEPTACLES 4 20/1 9 B 10 - - -- ------------- ---------------- --- ---- - - - -- 2900 2080 INSTAHOT 1 30/2 9 B 10 20/1 6 INVENTORY ROOM RECEPT. 1080 MAIN: 120/208 VOLT / 3 PHASE / 4 WIRE MAIN BREAKER: MLO MOUNTING: SURFACE BUS: 1 SECTION: SINGLE LUGS NEMA ENCLOSURE 1 BUS: 60 AMP A.I.C. RATING: 22K 720 CASH REGISTER RECEPTACLES 4 20/1 11 C 12 25/2 1 CU -1 1750 2080 - - - - - - - - - -- 11 C 12 20/1 4 INVENTORY ROOM RECEPT. 720 360 CASH WRAP RECEPTACLES 2 20/1 13 A 14 ---- ----------------- -- --- ------------- - ----- 1750 2080 2080 1000 INSTAHOT - - - - - - - - FLOOR RECEPTACLES 1 2 30/2 - -- 20/1 13 15 17 A B C 14 16 18 2011 20/1 2011 11 14 1 2 TIME CLOCK BACK AREA LTG SALES AREA LIGHTING 200 755 746 LOAD VA 360 400 360 500 500 500 500 LOAD DESCRIPTION RTU RECEPTACLE DUCT SMOKE DETECTOR BACK AREA RECEPT. EQUIPMENT RECEPTACLE EQUIPMENT RECEPTACLE SPARE EQUIPMENT RECEPTACLE SPARE EQUIPMENT RECEPTACLE SPARE OUTLETS CB 1 P 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 t Y 0 1 3 5 7 9 11 13 15 17 19 w Q a A B C A B C A B C A u Y 0 2 4 6 8 10 12 14 16 18 20 CB / P 20/1 20/1 20/1 20/1 20/1 20/1 2011 2011 20/1 20/1 OUTLETS - - LOAD DESCRIPTION MANAGER OFFICE CCTV REC. MANAGER OFFICE RECEPT. MANAGER OFFICE RECEPT. REFRIGERATOR RECEPT. MICROWAVE RECEPTACLE OPEN OFFICE RECEPTACLES OPEN OFFICE RECEPTACLES OPEN OFFICE RECEPTACLES PRINTER / COPIER RECEPT. SPARE LOAD VA 360 720 720 600 600 360 720 360 800 720 CASH REGISTER RECEPTACLES 4 20/1 15 B 16 20/1 SPARE M 2 R 2 2 1 1 1 1 L L R 2 4 4 1 2 2 4 2 2 M 720 CASH REGISTER RECEPTACLES 4 20/1 17 C 18 20/1 SPARE 900 SALES AREA RECEPTACLES 5 20/1 19 A 20 20/1 SPARE 1000 FLOOR RECEPTACLES 2 20/1 19 A 20 20/1 7 SALES AREA LIGHTING (TRACK) 1050 720 SALES AREA RECEPTACLES 4 20/1 21 B 22 20/1 SPARE 1000 FLOOR RECEPTACLES 2 20/1 21 B 22 20/1 SPARE 500 PRINTER RECEPTACLE 2 20/1 23 C 24 20/1 SPARE 1000 FLOOR RECEPTACLES 2 20/1 23 C 24 20/1 8 SALES AREA LIGHTING (TRACK) 1200 720 SALES AREA RECEPTACLES 4 20/1 25 A 26 20/1 SPARE 500 FLOOR RECEPTACLES 1 20/1 25 A 26 20/1 22 SALES AREA LIGHTING 1300 720 SALES AREA RECEPTACLES 4 20/1 27 B 28 20/1 SPARE 360 SALES AREA RECEPTACLES 2 20/1 27 B 28 20/1 24 SALES AREA LIGHTING 1380 500 PRINTER RECEPTACLE 2 20/1 29 C 30 2011 SPARE 1500 SHOW WINDOW RECEPTACLE 1 20/1 29 C 30 20/1 25 SALES AREA LIGHTING 1445 720 SALES AREA RECEPTACLES 4 20/1 31 A 32 20/1 SPARE 1500 SHOW WINDOW RECEPTACLE 1 20/1 31 A 32 20/1 8 SALES AREA DAY LIGHTING 530 720 SALES AREA RECEPTACLES 4 2011 33 B 34 20/1 2 FLOOR RECEPTACLES 1000 1500 SHOW WINDOW RECEPTACLE 1 2011 33 B 34 20/1 9 SALES AREA DAY LIGHTING 595 500 PRINTER RECEPTACLE 2 20/1 35 C 36 20/1 2 FLOOR RECEPTACLES 1000 1500 SHOW WINDOW RECEPTACLE 1 20/1 35 C 36 20/1 SPARE 180 SALES AREA RECEPTACLES 1 2011 37 A 38 60/3 1 SUB -PANEL "C" 3040 1200 SHOW WINDOW RECEPTACLE 1 20/1 37 A 38 20/1 1 STORE SIGNAGE 1200 SPARE 2011 21 B 22 20/1 SPARE 180 SALES AREA RECEPTACLES 1 20/1 39 B 40 - - -- --------------- -------------------- - -- - -- 2580 1200 SHOW WINDOW RECEPTACLE 1 20/1 39 B 40 20/1 1 STORE SIGNAGE 1200 SPARE B 20/1 C 23 C 24 PANEL 20/1 LOCATION: SPARE 500 EQUIPMENT RECEPTACLE 1 20/1 41 C 42 - - -- ----------- -- --------- ------------- - ----- 2740 1200 SHOW WINDOW RECEPTACLE 1 20/1 41 C 42 20/1 1 STORE SIGNAGE 1200 PHASE A 3040 8360 STORE PHASE A B C PANEL LOCATION: STORE AREA SERVED: STORE PHASE A B C PANEL LOCATION: STORE AREA SERVED: STORE . -- - PHASE TOTAL VA: PANEL TOTAL: CONNECTED 2580 VA 2740 AREA SERVED: STORE PHASE TOTAL VA: 17290 16980 15650 PHASE TOTAL VA: 15540 15090 17171 FED FROM: PANEL "B" PANEL TOTAL: CONNECTED 49920 VA FED FROM: 400 AMP SERVICE PANEL TOTAL: CONNECTED 47801 VA FED FROM: 400 AMP SERVIC - Ike (L.C.L.) §125%: (0) 0 VA EXISTING PANEL LOAD: 0 VA 25% PER NEC 220 -35 (2): 0 VA LESS LOAD REMOVED: 0 VA DEMAND LOAD ON SUB -PNL: VA PLUS LOAD ADDED: 8360 VA NEW PANEL LOAD: 8360 VA 23.2 FULL LOAD AMPS (L.C.L.) @125 %: (0) 0 VA EXISTING PANEL LOAD: 0 VA 25% PER NEC 220 -35 (2): 0 VA LESS LOAD REMOVED: 0 VA DEMAND LOAD ON SUB -PNL: 0 VA PLUS LOAD ADDED: 54420 VA 00 •' • De coo(�p . �i "p�70 $� ` 11 � 9 'n(V J1°° L � �tolla (�j�a:�' # 1� � � .,_ ° ~ ' • (SIGNS & SHOW WIND. @1 (0) WATER HEATER @ 125% (0) 0 VA 0 VA (SIGNS & SHOW WIND. @1: (0) 0 VA • WIND. 11 16500 VA 1 WATER HEATER @ 125% (0) 0 VA • 15600 VA LOAD REMOVED: 1 (HVAC) @ 100 %: (0) 0 VA (HVAC) @ 100 %: (9300) 9300 VA . 0 VA GEN. RECEPT. DEMAND (3600) 3600 VA GEN. RECEPT. DEMAND (4080) 4080 VA GEN. RECEPT. DEMAND 7920 VA DEMAND •' • (LARGEST MOTOR) @125 ° / (0) 0 VA (LARGEST MOTOR) @125 °A (18000) 22500 VA • ' • • 0 VA REMAINING @100% PANEL TOTAL W/ DEMAND: 4760 VA 8360 VA REMAINING @100% 18540 VA 5200 VA • • ADDED: PANEL TOTAL W/ DEMAND: 54420 VA NEW PANEL LOAD: 54420 VA 151.2 FULL LOAD AMPS PANEL TOTAL W/ DEMAND: 56471 VA NEW PANEL LOAD: 56471 VA 156.�' FULL LOAD AMPS PANEL SCHEDULES AND LOAD CALCULATION SCALE: 3 NONE COPYRIGHT 0 2008 CAREER & BURGESS, INC. at &t Carter::Burgess Carter & Burgess, Inc. 4 Hutton Centre Drive, Suite 800 Santa Ana, California 92707 TEL: (714) 327 -1600 FAX: (714) 327 -1601 EXPIRES 08/26/09 ISSUES /REVISIONS 3 07 -16 -08 TENANT CHANGES 2 04 -17 -08 REVISED ELECTRICAL SERVICE 1 03 -29 -08 TENANT CHANGES 03 -19 -08 ISSUE FOR PERMIT NO. DATE DESCRIPTION 16425 Southcenter Parkway TU KW I LA, WA DRAWN BY: RT DESIGNED BY: RT CHECKED BY: BLD APPROVED BY: CNB PROJECT NUMBER: SCALE: 441805.011.028.0001 AS SHOWN ELECTRICAL PANEL SCHEDULES, DETAILS AND SINGLE LINE DIAGRAM E 103