Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0301 - METRO MAINTENANCE BUILDING
METRO MAINTAINENCE BUILDING 12100 EAST MARGINAL WAY S ELO8-301 CRAM' Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 7340600421 Address: 12100 EAST MARGINAL WY S TUKW Suite No: Permit Number: EL08 -301 Issue Date: 04/08/2008 Permit Expires On: 10/05/2008 Tenant: Name: METRO MAINTENANCE BUILDING Address: 12100 EAST MARGINAL WY S , TUKWILA WA Owner: Name: KING COUNTY Phone: Address: 500 K C ADMEN. BLDG , SEATTLE WA Contact Person: Name: PATTY FULLER Phone: 253 661 -7181 Address: 37107 12 AV S , FEDERAL WAY WA Contractor: Name: FULLER ELECTRIC CO Address: 37107 12 AV S , FEDERAL WAY WA Contractor License No: FULLEEI027BK Phone: Expiration Date: 01/12/2010 DESCRIPTION OF WORK: 1. INSTALL (1) 30 KVA TRANSFORMER 2. INSTALL 15 AMP TO 20 AMP (15) 3. INSTALL (1) 80 AMP Value of Electrical: $54,500.00 Fees Collected: $1,202.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: Date: `` —U- o U I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th erformance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -301 Printed: 04 -08 -2008 V A. • 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 7340600421 Address: 12100 EAST MARGINAL WY S TUKW Suite No: Tenant: METRO MAINTENANCE BUILDING Permit Number: EL08 -301 Status: ISSUED Applied Date: 03/24/2008 Issue Date: 04/08/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 0 C ,,f Print Name: , � `Z AnY1 FtM k Date: Li- 9 -- O doc: Cond -Elec EL08 -301 Printed: 04 -08 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Electrical Permit No. • j Project No: *dt (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 2 16'a �. Tenant Name: 161 Property Owners Name: /A /DO Mailing Address: �(L 5 Suite Number: Floor: Olf4A4417 ew Tenant: ❑ Yes 2?. No ngt -Q- wag- 5. Ste-L. u - fg /(0 q't )el ,ritkial: 7 , )14 901 2rISTre) King Co Assessor's Tax No.: if,c(io z- City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Mailing Address: 3 n 10'7 I2 V u — G0 4A 7tG ti o! b 3 City State Zip E -Mail Address: gala,. �- ' O1 • �!%�� Fax Number: Cf 53 't'o ' / `(o9s pect-t rtzi t. Day Telephone: z53 6 / 7 /g' ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: Contact Person: E -Mail Address rave, etta-yu.„,A, 37,07 my-A-- avea .--- 55us, 9cd&L-. t al , 3 City state p Day Telephone: Fax Number: Expiration Date: ,?5.3 -&' / -7/8/ POT a- a l - ce' - a53- Contractor Registration Number: 11A 10.0-"(b.)-7. 6f< O(--1)-.).0(e, Valuation of Project (contractor's bid price): $-4 .. /, SO Q S pe of Work (please provide detailed information): t• Ptt, 3° 3A �. 9 is w-p it) /0 7+ (j ) Will service be altered? ❑ Yes [' No Adding more than 50 amps? ❑ Yes [.i]-No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service 3• D ❑ Remodel ❑ Tenant Improvement Property Served by: ❑ Puget Sound Energy Seattle City Light H \Apphcmons\Forms- Applications On !Ana \4-2007 - Electrical Penult Application.doc bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals.. $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: •, Signature: try Print Name: Mailing Address: IDate Application Accepted: 7/07 /44_ Date: ✓j! ai / Day Telephone: 0763 -(p4'(—?i / 5014514, rat, 0 4 - v - ' 4 4 - c' 3 City State Zip Date Application Expires: 61 I 0 • t�� H VApplicaaonstFonns- Applications On t�net4 -2017 - Electrical Permit Application doc bh Staff Initials: r_ I Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 7340600421 Permit Number: EL08 -301 Address: 12100 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 03/24/2008 Applicant: METRO MAINTENANCE BUILDING Issue Date: Receipt No.: R08 -01072 Initials: WER User ID: 1655 Payment Amount: $962.00 Payment Date: 04/08/2008 11:40 AM Balance: $0.00 Payee: FULLER ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1178 962.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 962.00 Total: $962.00 don. Raraint -nR Printarl. 04- nR -2nnA City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www, ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -00879 Initials: JEM Payment Date: 03/24/2008 User ID: 1165 Payee: FULLER ELECTRIC INC Total Payment: 481.00 SET ID: 0324A SET NAME: FULLER ELECTRIC SET TRANSACTIONS: Set Member Amount rl 240.50 EL008 -304 240.50 TOTAL: 481.00 TRANSACTION LIST: Type Method Description Amount Payment Check 35295 481.00 TOTAL: 481.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 481.00 TOTAL: 481.00 Doc: RECSETS -06 917 INSPECTION NO. INSPECTION RECORD Retain a copy with permit u3 -30, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION -- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pro je t: 0 r AIAIT. 6 LOIN , Type of Inspection: /00 Address: � I 2100 £. Ica. vJli Date Called: Special Instructions: Date Wanted: g fro (/ m. Requester: Phone No: igi Approved per applicable codes. 0 Corrections required prior to approval. 4Q COMMENTS: Inspector: .1Tn &-wEic Date: 07//0/01 EJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .— Vest. .e,11. . •.sr • - .se ti .N6o1.4%11.0 -. Yom► 5..�. s• .�cM y.� ..� _. _- 09 -08 -2008 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director PATTY FULLER 37107 12 AV S FEDERAL WAY WA 98003 RE: Permit No. EL08 -301 12100 EAST MARGINAL WY S TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writini and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 10/05/2008 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, fer Marshall t Technician xc: Permit File No. EL08 -301 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 • Fax: 206-431-3665 OPERMIT COORD COPY 4111 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -301 DATE: 03 -24 -08 PROJECT NAME: METRO MAINTENANCE BUILDING SITE ADDRESS: 12100 EAST MARGINAL. WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENT: �� uYldi Bn g - Division 4v Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete I/1 Incomplete Comments: DUE DATE: 03-27 -08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU NG: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04 -24 -08 Approved Approved with Conditions VI Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electri n or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License FULLEEI027BK Licensee Name FULLER ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601840365 Ind. Ins. Account Id Business Type CORPORATION Address 1 37107 12TH AVE S Address 2 City FEDERAL WAY County KING State WA Zip 98003 Phone 2536617181 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/12/1998 Expiration Date 1/12/2010 Suspend Date Separation Date Parent Company Previous License FULLEE*088NE Next License Associated License FULLEPA035NZ Electrical Administrator Information License FULLEPA035NZ Name FULLER, PATRICIA ANN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FULLER, GREGORY C 01/01/1980 FULLER, PATRICIA ANN 01/01/1980 S C & B SERVICES INC AGENT 01/01/1980 a 1 1 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= FULLEEI027BK 04/08/2008 POLE ©OW Permit rrPv1,0•Ar g1.,0 0 Vty of Tukvine. • BUILORNG DIMSION REVISION No changes shall be ma of work without prior Tukwila Building Revisions will require and may include additional, e to the scope pproval of 'vision. new plan submittal n review fees. ATLANTIC AND SOUTH BASE EXHAUST FAN REPLACEMENT Contract C00130007 • King County Department of Transportation Transit Division SEPARATE PERMIT REQUIRED FOR: EVIVIethanical Electdoel NOlumbing Cr Gas Rift City of Tukwils BUILDING DIVISION Volume 2 of 2 Contract Drawings May 2007 CITY OF TUKINiLA MAR 2 4 2008 PERMIT CENTER EI,01Y- ( ATLANTIC AND SOUTH BASE EXHAUST FAN REPLACEMENT Contract C00130007 King County Department of Transportation Transit Division Volume 2 of 2 Contract Drawings May 2007 RECEIVED CITY OF TUKWILA MAR 24ZUU8 PERMIT CENTER GENERAL unrcc 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE 2003 INTERNATIONAL, BUILDING CODE; AND THE LATEST EDITION OF THE IUKW1LA AND SEAU E BUILDING CODES AND AMENDMENTS, AS APPLICABLE TO EACH LOCATION. A COPY OF THE APPROVED PLANS MUST BE ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL BUILDING UTILITY AND STRUCTURE LOCATIONS SHOWN AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES OR APPURTENANCES NOT SHOWN HEREON WHICH MAY BE AFFECTED BY THE IMPLEMENTATION OF THIS PLAN. 3. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND LOCATIONS PRIOR TO START OF WORK. 4. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING BUILDING UTILITIES, EQUIPMENT, FINISH SYSTEMS AND SURFACES REMAINING IN THE WORK AREA DURING CONSTRUCTION. PEMOLITION NOTES 1. THE CONTRACTOR SHALL REMOVE AND DISPOSE OF ALL REMOVED MATERIALS WITHIN THE WORK AREA. 2. THE CONTRACTOR SHALL REMOVE AND REPLACE DETERIORATED WOOD AND CONCRETE BLOCKING AND NAILERS IN ACCORDANCE WITH THE DRAWINGS AND AS DISCOVERED, AFTER APPROVAL BY THE KING COUNTY PROJECT REPRESENTATIVE. 3. ALL DEMOLITION DEBRIS MUST BE DISPOSED OF LEGALLY, OFF SITE. DRAWING NUMBERING SYSTEM KEY: DISCIPLINE G C L A 5 M FP E T GENERAL CIVIL LANDSCAPE ARCHITECTURE STRUCTURAL MECHANICAL FIRE PROTECTION ELECTRICAL TROLLEY DESIGNATED CATEGORY 0 GENERAL 1 PLANS 2 ELEVATIONS 3 4 5 6 7 8 AREA LOCATION 9 (FOR PROJECTS WITH C1 0 1 MULTIPLE LOCATIONS) - DISCIPLINE DESIGNATOR SEPARATOR SECTIONS ENLARGED PLANS DETAILS SCHEDULES & DIAGRAMS USER DEFINED USER DEFINED 3D VIEWS SEQUENTIAL DRAWING NUMBER WITHIN DISCIPLINE AND DESIGNATED CATEGORY TYPICAL SECTION AND DETAIL REFERENCING SYSTEM (1) THE SECTION IS CUT ON DRAWING A1.01: A1.05 SECTION LETTER v- ELEVATION LETTER A /A1.05 DRAWING WHERE SECTION OR ELEVATION APPEARS, USE DASH ( - - -) IF ON SAME DRAWING (2) ON DRAWING A1.05 THIS SECTION IS IDENTIFIED: SECTION OR ELEVATION LETTER SECTION SCALE: 1"= l'-0" A1.01 DRAWING REFERENCED FROM, USE DASH ( - - -) IF ON SAME DRAWING (3) DETAILS ARE CROSS- REFERENCED IN A SIMILAR MANNER, EXCEPT THAT DETAILS ARE IDENTIFIED BY NUMBERS RATHER THAN BY LETTERS. SHEET NO, DRAWING NO, I N D E X T O D RAW I N G S GENERAL DRAWINGS DRAWING TITLE 1 G1.01 VICINITY MAP AND INDEX TO DRAWINGS 2 G1.02 ATLANTIC BASE LOCATION MAP AND SITE PLAN 3 G1.03 SOUTH BASE LOCATION MAP AND SITE PLAN GENERAL ARCHITECTURAL 4 A5.01 EQUIPMENT CURB CONSTRUCTION DETAILS 5 A5.02 GENERAL ELECTRICAL 5 E5.01 7 E6.01 8 E6.02 9 E6.03 CONSTRUCTION DETAILS ELECTRICAL DETAILS EXHAUST FAN CONTROLS LAYOUT EXHAUST FAN CONTROLS SCHEMATIC EXHAUST FAN CONTROLS EQUIPMENT SCHEDULE VICINITY MAP 0 246 MILES SHEET NO DRAWING NO, DRAWING TITLE ATLANTIC BASE ARCHITECTURAL 10 1 A4.01 FUEL /WASH & MAINTENANCE BUILDINGS PARTIAL PLANS & DETAILS MECHANICAL 11 1 M1.01 FUEL AND WASH BUILDING ROOF PLAN 12 1 M1.02 FUEL AND WASH BUILDING PARTIAL PLANS 13 1 M1.03 MAINTENANCE BUILDING ROOF PLAN 14 1 M3.01 ELEVATION AND SECTIONS 15 1 M5.01 MECHANICAL DETAILS 16 1 M5.02 MECHANICAL DETAILS 17 1 M5.03 MECHANICAL DETAILS 18 1 M6.01 EQUIPMENT SCHEDULE ELECTRICAL 19 20 21 22 23 24 25 26 27 28 29 30 E1.01 FUEL AND WASH BUILDING ROOF PLAN E1.02 FUEL AND WASH BUILDING FIRST FLOOR PLAN E1.03 MAINTENANCE BUILDING ROOF PLAN E1.04 MAINTENANCE BUILDING FIRST FLOOR PLAN E1.05 MAINTENANCE BUILDING SECOND FLOOR PLAN E3.01 ELEVATION AND SECTIONS E6.01 ONE -LINE DIAGRAM E6.02 PANEL SCHEDULES E6.03 PANEL SCHE E6.04 PANEL SCHE E6.05 PANEL SCHED E6.06 SCHEMATICS SHEET NO DRAWING NO SOUTH BASE ARCHITECTURAL DRAWING TITLE 31 2 A5.01 MAINTENANCE BUILDING CONSTRUCTION DETAILS STRUCTURAL 32 2 54.01 MAINTENANCE BUILDING PARTAL PLAN & DETAILS 33 2 S5.01 MAINTENANCE BUILDING CONSTRUCTION DETAILS 34 2 55.02 MAINTENANCE AND OPERATIONS BUILDINGS CONSTRUCTION DETAILS MECHANICAL 35 2 M1.01 36 2 M1.02 37 2 M1.03 38 2 M3.01 39 2 M3.02 40 2 M5.01 41 2 M5.02 42 2 M5.03 43 2 M6.01 ELECTRICAL 44 2 El .01 45 2 [1.02 46 2 E1.03 47 2 E1.04 48 2 E4.01 49 2 E4.02 50 2 E6.01 2 E6.02 2 [5.03 2 E6.04 FUEL AND WASH BUILDING ROOF PLAN FUEL AND WASH BUILDING FIRST FLOOR PLAN MAINTENANCE BUILDING ROOF PLAN ELEVATIONS & SECTIONS EQUIPMENT ROOM PLAN AND SECTIONS MECHANICAL DETAILS MECHANICAL DETAILS MECHANICAL DETAILS EQUIPMENT SCHEDULE FUEL AND WASH BUILDING ROOF PLAN FUEL AND WASH BUILDING FIRST FLOOR PLAN MAINTENANCE BUILDING ROOF PLAN MAINTENANCE BUILDING FIRST FLOOR PLAN COMPRESSOR ROOM PLAN AND SECTIONS EQUIPMENT ROOM DETAIL AND SECTIONS ONE LINE DIAGRAM PANEL SCHEDULES PANEL SCHEDULES SCHEMATICS RECEIVED CITY OF TUKVVILA MAR Z 41008 PERMIT CENTER ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT CONTRACT NO. C00130007 A No. REVISION BY APP'D DATE DESIGNED: J. TURNER -a- DRAWN: Ada J. BICKERSTAFF CHECKED: R. QUIST RECOMMENDED: D. CRIPPEN PROJECT MANAGER: J� /// K. MADDEN /]-(/'� APPROVED: V l B. ISLER' IBS No: 432692/432721 M0Jx J®IQS' - CONTRACT NO: C00130007 SCALE NONE ONE INCH AT FULL SIZE • IF NOT ONE INCH. SCALE ACCORDINGLY SITE LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT VICINITY MAP & INDEX TO DRAWINGS DATE: MAY 2007 DRAWING NO.. G1.01 SHEET NO: O; 1 53 LEGEND Cable Area BUILDING AT LOT LINE FUEL & WASH BUILDING E L L/ O T T B A Y CONTRACTOR STAGING AREA APPROX 15'x30' WEST YARD MAINTENANCE BUILDING 01 656' LOCATION MAP S MASSACHUSETTS ST - - - ATLANTIC BASE SITE PLAN 0 1 8 1 4 3 8 1 2 3 4 1 MILES PROJECT ADDRESS 1333 AIRPORT WAY SOUTH SCALE: 1"=400' LEGAL DESCRIPTION THOSE PORTIONS OF BLOCKS 245, 247, AND 248 OF SEATTLE TIDE LANDS. ACCORDING TO THE MAPS ON FILE IN THE OFFICE OF THE COMMISSIONER OF PUBLIC LANDS. IN OLYMPIA, WASHINGTON, AND THAT PORTION OF VACATED SOUTH ATLANTIC STREET, VACATED 8TH AVENUE SOUTH AND VACATED AIRPORT WAY SOUTH, ALL LOCATED IN SECTION 5 AND SECTION 8, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., DESCRIBED AS FOLLOWS: BEGINNING AT SOUTHWEST CORNER OF LOT 11, BLOCK 248 OF SAID SEATTLE TIDE LANDS; THENCE NORTH 01'06'30" EAST ALONG THE EASTERLY RIGHT -OF -WAY MARGIN OF 6TH AVENUE SOUTH, A DISTANCE OF 659.96 FEET TO THE NORTHWEST CORNER OF LOT 1 DF SAID BLOCK 248; THENCE SOUTH 88'51'13" EAST ALONG THE SOUTHERLY RIGHT -OF -WAY MARGIN OF SOUTH ATLANTIC STREET, A DISTANCE OF 133.00 FEET; THENCE NORTH 0r08'57" EAST ALONG A LINE, A DISTANCE OF 5D.00 FEET TO A POINT; THENCE SOUTH 88'51'13" EAST ALONG A UNE, A DISTANCE OF 10.75 FEET TO A POINT; THENCE NORTH 01'08'57" EAST ALONG A LINE. A DISTANCE OF 50.00 FEET TO A POINT ON THE NORTHERLY RIGHT -OF -WAY MARGIN OF SOUTH ATLANTIC STREET; THENCE NORTH 88'51'13" WEST ALONG SAID NORTHERLY RIGHT -OF -WAY MARGIN, A DISTANCE OF 143,78 FEET TO THE SOUTHWEST CORNER OF LOT 11, BLOCK 247 OF SAID SEATTLE TIDE LANDS; THENCE CONTINUING NORTH 01'08'57" EAST ALONG SAID EASTERLY RIGHT -OF -WAY MARGIN OF 6TH AVENUE SOUTH, A DISTANCE OF 660.12 FEET TO THE NORTHWEST CORNER DF LOT 1 OF SAID BLOCK 247; THENCE SOUTH 88'52'13" EAST ALONG THE SOUTHERLY RIGHT -OF WAY MARGIN OF SOUTH ROYAL BROUGHAM WAY AND NORTH LINE OF SAID LOT 1, A DISTANCE OF 133.75 FEET TO THE NORTHWEST CORNER OF THE EAST 45 FEET OF THE WEST 178.75 FEET OF SAID LOT 1; THENCE SOUTH 01'08'57" WEST, A DISTANCE OF 13.00 FEET AS CONVEYED TO THE STATE OF WASHINGTON BY DEED RECORDED UNDER RECORDING NO. 8805030703: THENCE SOUTH 88'52'13" EAST, A DISTANCE OF 45.00 FEET; THENCE NORTH 01'08'57" EAST. A DISTANCE OF 13.00 FEET TO THE NORTHEAST CORNER OF THE WEST 178.75 FEET OF SAID LOTI; THENCE SOUTH 88'52'13" EAST ALONG THE NORTH LINE OF SAID BLOCK 247, A DISTANCE OF 243.29 FEET TO THE NORTHEAST CORNER OF LOT 22 OF SAID BLOCK 247 AND BEGINNING OF THAT PORTION OF VACATED AIRPORT WAY SOUTH, AS DESCRIBED IN CITY OF SEATTLE ORDINANCE NO. 103835, RECORDED UNDER RECORDING NO. 7410030321; THENCE CONTINUING SOUTH 88'52'13" EAST, A DISTANCE OF 8.80 FEET TO THE BEGINNING OF A CURVE, CONCAVE TO SOUTHWEST, HAVING A RADIUS OF 50.00 FEET. AND A CENTRAL ANGLE OF 61'27 "20 "; THENCE SOUTHEASTERLY ALONG SAID CURVE, A DISTANCE OF 53.63 FEET; THENCE SOUTH 27'24'53" EAST, A DISTANCE OF 15.21 FEET TO THE BEGINNING OF A CURVE, CONCAVE TO THE SOUTHWEST, HAVING A RADIUS OF 285.68 FEET, AND A CENTRAL ANGLE OF 4'47'07 "; THENCE SOUTHERLY ALONG SAID CURVE 23.86 FEET; THENCE SOUTH 2737'46' EAST PARALLEL WITH AND 40 FEET EASTERLY OF THE EAST LINE OF SAID BLOCK 247, A DISTANCE OF 376.13 FEET TO THE BEGINNING OF A CURVE, CONCAVE TO THE WEST, HAVING A RADIUS OF 286.00 FEET, AND A CENTRAL ANGLE OF 1726'05 "; THENCE SOUTHERLY ALONG SAID CURVE 82.07 FEET; THENCE SOUTH 10'16'04" EAST ALONG THE EAST UNE OF CITY OF SEATTLE VACATION ORDINANCE NO. 111289 AND ORDINANCE NO. 113655, A DISTANCE OF 183.72 FEET; THENCE SOUTH 22'38'04" EAST, A DISTANCE OF 220.67 FEET; THENCE SOUTH 29'15'55" EAST, A DISTANCE OF 51.91 TO THE EAST LINE OF SAID BLOCK 245; THENCE SOUTH 2737'07" EAST ALONG SAID EAST UNE AND WESTERLY RIGHT -OF -WAY MARGIN OF AIRPORT WAY SOUTH, A DISTANCE OF 535.20 FEET; THENCE SOUTH 01'08'55" WEST, A DISTANCE OF 39.31 FEET TO THE SOUTH EAST CORNER OF LOT 10 OF SAID BLOCK 245; THENCE NORTH 88'51'40" WEST ALONG THE NORTHERLY RIGHT -OF -WAY MARGIN OF SOUTH MASSACHUSLI TD STREET, A DISTANCE OF 470.06 FEET; THENCE NORTH 88'51'52" WEST ALONG SAID RIGHT -OF -WAY MARGIN. A DISTANCE OF 559.80 FEET TO THE POINT OF BEGINNING; SITUATE. IN THE CITY OF SEATTLE, KING COUNTY, WASHINGTON. TGW POR OF SOUTH ATLANTIC STREET PETITIONED TO BE VACATED UNDER CF 304924. ASSESSOR'S PARCEL NUMBERS 766620 -3345 766620 -3385 766620 -3390 766620 -3386 766620 -3387 766620 -3400 766620 -3415 RECEIVE F CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: _ma R. OUIST RECOMMENDED: I it D. CRIPPEN B. ISLER OS NO 432692/432721 Maas Imams.: - CONfRACT NO: C00130007 SCALE: NONE ONE INCH AT FULL SIZE 1' IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE LOCATION MAP & SITE PLAN DA MAY 2007 DRAWING NO:. G1.02 SHEET NC: GF 2 53 . ,.. �■■ u���l. 1P., . •1 . �, ���n1!�II► �i_:S & PROJECT LOCATION _ ►_ 12100 EAST MARGINAL WAY S. ` r► • lalETPPASI LEGAL DESCRIPTION PORTIONS OF THE WEST HALF OF SECTION 10. TOWNSHIP 23 NORTH. RANGE 4 EAST, W. M., DESCRIBED AS FOLLOWS: LOTS 22. 23, 24 AND THAT PORTION OF LOT 25 OF BENNEIT'S INTERURBAN TRACTS UNRECORDED, LYING NORTH OF A LINE 50 FEET SOUTH OF THE NORTH LINE OF GOVERNMENT LOT 15 OF SAID SECTION 10, AND LOTS 17, 18, 19, 20, 21, 22, AND THE RIVERSIDE STONE QUARRY OF RIVERSIDE INTERURBAN TRACTS, AS RECORDED IN VOLUME 10 OF PLATS ON PAGE 74, RECORDS OF KING COUNTY AND RIVER STREET AS VACATED BY SUPERIOR COURT CAUSE NO. 663488. ALL LYING SOUTHWESTERLY OF PRIMARY STATE HIGHWAY NO. 1, FOSTER INTERCHANGE TO SOUTH 118TH STREET. AS ESTABLISHED BY WARRANTY DEED, KING COUNTY AUDITOR'S FILE NO. 5884778, AND SUPERIOR COURT CAUSE NO. 646846 AND NORTHEASTERLY OF EAST MARGINAL WAY SOUTH AS ESTABUSHED BY SUPERIOR COURT CAUSE 646697, 646846 AND 646939 AND THAT PORTION DEEDED TO KING COUNTY BY OUIT CLAIM DEED AS RECORDED UNDER AUDITOR'S FILE NO. 1004994, AND WARRANTY DEED NO. 7412090465. MAINTENANCE BUILDING OPERATIONS BUILDING CONTRACTOR'S ENTRANCE FUEL AND WASH BUILDING LEGEND AREA OF WORK RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER A L. \ A No. REVISION BY APP'D DATE DESIGNED: `� J. TURNER `� DRAWN: J. BICKERSTAFF0 CHECKED: R. QUIST RECOMM D. CRIPPEN PROJECT IIAIIAGEI K. MADDEN NONE APPROVED: B. ISLER IBIS NO: 432692/432721 RCM REQUEST - CON1RACT NO, C00130007 ONE INCH AT FULL SIZE 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO ring County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE LOCATION MAP & SITE PLAN DATE: MAY 2007 DRAWING NO: G1.03 SHEET NO: OF 3 53 m - r m a 0, o oC " SEALING MATERIAL SHEET METAL FLASHING RECEIVER HIGH - DOMED, CAPPED, GASKETED FASTENERS (APPROX 18" OC MINIMUM TWO FASTENERS PER SIDE) REMOVABLE SHEET METAL COUNTERFLASHING FASTENERS APPROX 8" OC REPLACE BASE FLASHING ONLY IF DAMAGED DURING EQUIPMENT REMOVAL AND INSTALLATION LAP ROCK BALLAST TO CANT WHERE PRESENT EXIST NG WOOD OR CONCRETE yI CURBING AND NA'LERS 10 REMAIN y TYPICAL EXISTING CURB FOR EXHAUST FANS AND EQUIPMENT DETAIL (11 SCALE: NONE VARIES NEW FIRE RETARDANT TREATED WOOD SPACER, AS REQ'D. SEE NOTE 2-- SEALING MATERIAL SHEET METAL FLASHING RECEIVER 4" MIN 4" MIN EXISTING 0JRBING r- WOOD OR CONCRETE AND NA LERS TO REMA■N s EX STING ROCF SYSTEM AND CAN '0 RLMAIN N LACE EX STING CONSRFTE ROO' :)ECK TIE PLATE, SIMPSON TP45 OR EQUAL WITH MIN SIX 8dx13 NAILS IN EACH MEMBER (TYP 2 PLATES PER SIDE). SEE NOTE 4 HIGH - DOMED, CAPPED, GASKETED FASTENERS (APPROX 18" OC MINIMUM TWO FASTENERS PER SIDE) INSTALL NEW SHEET METAL COUNTERFLASHING TO EXTEND MIN 1" BELOW NEW CURB EXTENSION FASTENERS APPROX B" OC LAP NEW FLASHING OVER EXISTING, REPLACE BASE FLASHING IF DAMAGED DURING EQUIPMENT REMOVAL AND INSTALLATION LAP ROCK BALLAST TO CANT WHERE PRESENT TYPICAL CURB HEIGHT INCREASE FOR EXHAUST FANS AND EQUIPMENT DETAIL SCALE: NONE VARIES No. REVISION BY APP'D DATE EXISTING R00 SYSTEM AND CAN TO REMAIN IN PLACE - EXISTING CONCRETE R00E DECK SEALING MATERIAL SHEET METAL FLASHING RECEIVER REMOVABLE SHEET METAL COUNTERFLASHING REPLACE BASE FLASHING ONLY IF DAMAGED DURING EQUIPMENT REMOVAL AND INSTALLATION 4" MIN 4" MIN LAP ROCK BALLAST TO CANT WHERE PRESENT 1 v 1-_G NEW PREFABRICATED METAL CURB W/ FLASHING FLANGE AND WOOD NAILER Vs— TYPICAL NEW PREFABRICATED CURB FOR EXHAUST FANS AND EQUIPMENT DETAIL SCALE: NONE VARIES - EX ;ST NG R00F S" S"FM TO REMAIN IN PACE EXIST NG CONCRETE ROOF DECK — EXISTING T - `SEAM AI DETAIL 5/2 44.01 SEALANT ALL AROUND 1" x 16 GA SS CLAMP W /SS BOLT, NUT & WASHER - STORM COLLAR FLASHING, LAP & SEAL © JOINT 24 GA STAINLESS STEEL FLASHING. LAP MIN 1", RIVET & SEAL 1 1/4" LONG STAINLESS STEEL SCREWS W/ NEOPRENE WASHERS ® 8" OC, 2 MIN PER SIDE OPENING EXTEND BASE FLASHING OVER TOP OF CURB AS SHOWN CONSTRUCTION NOTES; 1. WHERE NEW BLOCKING IS INSTALLED, ATTACHMENT SYSTEM TO THE EXISTING STRUCTURE SHALL BE AS SHOWN PER THE DRAWINGS, PER THE PROJECT SPECIFICATIONS AND AS APPROVED BY THE KING COUNTY PROJECT REPRESENTATIVE. 2. ALL FASTENERS IN PRESSURE- TREATED WOOD MUST BE STAINLESS STEEL. 3. THE PRE - STRESSED CONCRETE SLAB ROOF OF ATLANTIC BASE FUEL /WASH BUILDING (CITY DE SEATTLE SITE BUILDING #7) SHALL NOT BE CUT FOR ANY OPENINGS LARGER THAN 1" CONDUIT. CUTTING OR DAMAGING OF PRESTRESS TENDONS IN CONCRETE ROOF SLAB IS NOT PERMITTED. 4. WHERE HEIGHT INCREASE IS REQUIRED AND CONCRETE CURBS ARE ENCOUNTERED, MODIFY AT THE DIRECTION OF THE KING COUNTY PROJECT REPRESENTATIVE. LAP ROCK BALLAST TO CANT WHERE PRESENT NEW PREFABRICATED METAL CURB W/ FLASHING FLANGE AND WOOD NAILER DUCT PENETRATION ENCLOSURE DETAIL SCALE: NONE 1 M5.01 suv 1 REGISTERED! 1 ARCHITECT 1 FAkO STATE OF WASHINGTON DESIGNED: Y FARO DRAWN: B FARISS - BATEMAN CHECKED: J DAVIS RECOMME D CRIPPEN PROJECT MANAGER: K MADDDEN/ APPROVED: B ISLER IBIS NO: 432692 & 432721 MRS REQUEST: CONTRACT NO: _____ INSTALL RIGID INSULATION AROUND DUCT AS NOTED C00130007 ONE INCH AT FULL SIZE TG IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: EXISTING ROCE SYSTEM ; REMAIN IN .ACF EXISTING CCNCRE "E ROOF DEC< ABBREVIATIONS: APPROX GA MAX MIN OC REQ'D SS TYP W/ APPROXIMATE GAGE MAXIMUM MINIMUM ON CENTER REQUIRED STAINLESS STEEL TYPICAL WITH REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC APR - 3 2008 �D Of Tukwila IN RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT DATE MAY 2007 King County Department of Transportation EQUIPMENT CURB CONSTRUCTION DETAILS DRAWING NO- A5.0 1 SHEET NO: OF 4 53 JOIN PRESSURE TREATED WOOD BLOCKING WITH Y4" x 3" LONG STAINLESS STEEL SCREWS 3 "0 GALVANIZED STEEL STANCHION. SEE X5.01 SEALANT ALL AROUND 1" x 16 GA SS CLAMP W /SS BOLT, NUT & WASHER 24 GA SS STORM COLLAR FLASHING, LAP & SEAL ® JOINT 24 GA SS FLASHING. LAP MIN 1 ", RIVET & SEAL 1 1/4" LONG STAINLESS STEEL SCREWS W/ NEOPRENE WASHERS ® 8" DC, 2 MIN PER SIDE t el I ��I, ..i_ ___m — ■ m '���� • 4" MIN OVERLAP /BASE FLASHING MATERIAL EXIST.NC CONCRETE ROOF DECK CUT EXISTING INSULATION TO ACCOMMODATE NEW BLOCKING TYPICAL STANCHION SUPPORT FOR DISCONNECT SWITCH DETAIL (T SCALE: NONE VARIES CANT STRIP SS Yz "DIA X 2Y4" EMBEDMENT EXPANSION ANCHOR TO CONCRETE TOPPING SLAB, CUT WASHER UNDER HEAD (TYP - 4 PLACES /PLATE, 4 PLACES /BLOCKING) 12 "x12 "x3fi" GALVANIZED STEEL PLATE. STANCHION TO PLATE ASSEMBLY SHALL BE WELDED PRIOR TO GALVANIZATION SEALING MATERIAL SHEET METAL FLASHING RECEIVER 4" MIN 4" MIN Yh7Y a`"� STAINLESS STEEL CLAMP SELF ADHERING UNCURED EPDM MEMBRANE STAINLESS STEEL CLAMP SOLDERED LEAD JACK 5" FLANGE 1' -o" (TYP) CONDUIT. SEE ELECTRICAL DRAWINGS - SEALANT (TYP) SPECIFIED MEMBRANE STRIPPING PLIES ROUND PENETRATION SECTION SCALE: NONE VARIES STRUCTURAL CONSTRUCTION NOTES: 1. 2x10'S AND 2x12'S SHALL BE LAMINATED TOGETHER USING WATERPROOF WOOD GLUE AND THREE ROWS OF STAINLESS STEEL #10x2}4" SCREWS SPACED LONGITUDINAL I Y AT 6" OC, PER EACH 2x MEMBER. EXIST NC R00� EXIST NC CONC ROOF '._:LCK NOTE: SEE NOTE 3. DRAWING A5.01 SET X %) x 6" SS LAG BOLTS IN SEALANT NEOPRENE PAD a� = �� 22 GAGE STAINLESS 1� -' STEEL STEEL SHEET i� , 3s" EXTERIOR GRADE PLYWOOD r�►� !Ifh� n�m40 1'I I 1 1N1 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 3 2008 City Of Tukwila ILD ' IVI ION RECEIVED CITY OF TUKWILA MAR 2 4 2008 VIBRATION ISOLATOR (TYP) PERMIT CENTER - HIGH - DOMED, CAPPED, CASKETED FASTENERS (APPROX 18" 00) REMOVABLE SHEET METAL COUNTER FLASHING REPLACE BASE FLASHING ONLY IF DAMAGED DURING EQUIPMENT REMOVAL AND INSTALLATION LAP ROCK BALLAST TO CANT WHERE PRESENT NEW PREFABRICATED METAL CURB W/ FLASHING FLANGE AND WOOD NAILER SIMPSON HGA10 (TYP MIN 2 PER SIDE). INSTALL W/ SIMPSON SDS Y4" FASTENERS PER MANUF DIRECTIONS 111 y���• v •• ♦ ���vvvw� �r�v �� Vi- . ■■������� -. NEW EQUIPMENT CURB DETAIL SCALE: NONE VARIES 11 I 1 1 L.• SS 1/2 "DIA X 2 -1/4" EMBEDMENT EXPANSION ANCHOR TO CONCRETE TOPPING SLAB, CUT WASHER UNDER HEAD. MAX BOLT SPACING 12" OC (TYP) INSTALL INSULATION EQUAL TO ADJACENT EXISTING EXIS -INC R00= S''SEM "C REMAIN IN P P, EXIS -INC CONCRETE (3) 2x12'S - PRESSURE TREATED (TYP). CONNECT PER NOTE 1/— No. REVISION BY APP'D DATE DESIGNED: Y FARJO CHECKED: J DAMS PROJECT MANAGER K MADDDEN APPROVED: B ISLER IBIS NO: 432692 & 432721 VOW MEIDRSF SCALE AS NOTED RECOYMENDEO D CRIPPE ✓ ✓N{L✓ CONTRACT NO: CD0130007 DNE INCH AT FULL SIZE { 1 I IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT CONSTRUCTION DETAILS DATE: MAY 2007 DRAWING NO: A5.02 SHEET NO: OF 5 53 DISCONNECT SWITCH BOXES, EXIST ROOF DECK L PIPE B -LINE SYSTEMS, INC B3147A -3 GALV PIPE ANCHOR OR EQUAL TYP 3 "0 STD PIPE GALVANIZED WITH CAP A5.02 MECHANICAL EQUIPMENT LOCATE CONDUITS THRU ROOF BETWEEN A5.02 STEMS OF PRECAST ROOF BEAMS. ADJACENT TO PIPE STAND. TYP AT ROOF MOUNTED MECH EQUIP ROOF MOUNTED ELECTRICAL EQUPMENT DETAIL (T\ SCALE: LOCATE EQUIPMENT STAND PER EQUIPMENT REQUIREMENTS (SUBJECT TO CODE COMPLIANCE) z io COMBINATION MOTOR STARTER . 120V POWER DISC SW (WP) ` 120V RECEPTACLE (WP) RIGID CONDUIT (TYP) CHANNEL & PIPE CLAMPS CONDUITS THRU ROOF, LOCATE BETWEEN TEES OF PRECAST ROOF BEAMS, ADJACENT TO PIPE STAND RECEPTACLE CKT POWER SUPPLY B -LINE SYSTEMS, INC B3147A -3 GALV PIPE / ANCHOR OR EQUAL r TYP 3 "0 STD PIPE GALVANIZED WITH CAP ROOF MOUNTED CENTRIFUGAL EXHAUST FAN MOTOR CKT n A5.02 A5.02 LOCATE CONDUITS THRU ROOF BETWEEN STEMS OF PRECAST ROOF BEAMS, ADJACENT TO PIPE STAND. * PROVIDE DEVICES, SWITCHES AND WIRING WHERE INDICATED ON PLAN DRAWINGS. ROOF MOUNTED ELECTRICAL EQUPMENT DETAIL SCALE: LEGEND: a MOTOR STARTER DISCONNECT SWITCH a COMBINATION MOTOR STARTER CONDUIT DOWN '0' EXHAUST FAN MOTOR REi L CITY OF TUKWiLA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP.() DATE (OWOtFS 0 /T3/U8 DESIGNED: PROJECT MANAGER: L MCFARL)ID K. MADDEN/ APPROVED: B. ISLER 81$ NO: n1.,,,[1_,.t32692/432721 C. REYNOLDS v`°' =ex pause - RECOMMFNDED: CONTRACT NO. D CRIPPEN C000130007 SCALE: AS NOTED ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC & SOUTH BASE ELECTRICAL DETAILS DATE MAY 2007 DRAWING NO: E5.01 SHEET NO: OF 6 53 1 EXHAUST FAN CONTROLS EXHAUST FANS ON BAY NO.1 EXHAUST FANS ON BAY NO.2 0 MANUAL START 6 EXHAUST FAN CONTROLS DOOR (FRONT VIEW) 108 0 2 X 3 0 N N F1 C2 C3 C4 R1 I I O 0e. C1 2X3 TB M IIIIIIIuuuuuuIIIIIIIIIIIIIIIIIIIIIIIIIII! 0IIIIIIlIIIIIIuuIuIIIIIIUIIIIuIIIIIIIIII'l 2 X 3 EXHAUST FAN CONTROLS BACK PANEL RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER NOTES 1. PANEL SHALL BE CONSTRUCTED BY A SYSTEMS INTEGRATOR. LABEL PER UL STANDARDS. SYSTEMS INTEGRATOR SHALL BE CONTROL TECHNOLOGIES, KIRKLAND, WA; SYSTEMS INTERFACE, BOTHELL, WA. OR TECHNICAL SYSTEMS INC., LYNNWOOD, WA OR APPROVED EQUAL. 2. ALL WIRING 12 AWG MINIMUM STRANDED. ALL WIRES SHALL BE LABELED. EQUIPMENT SCHEDULE ITEM NUMBER, SEE DWG E6.03 No. REVISION BY APP'D DATE DESIGNED L MtFARL■ND REYNOLDS PROJECT NMHAGE1R1 I NYIJd_S�Y�M,, K. MADDE r,PQRGVED B. ISLER �, p 191S NO c J- X 432692/432721 ■ORIC 00011ETT: NT ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SHE LOCATION NO: [ovum 0/17/ OS D CRIPPEN C00130007 King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC AND SOUTH BASE EXHAUST FAN CONTROLS LAYOUT DATE MAY 2D07 DRAWING MO- E6.01 SHEET NO1 OF 7 53 TB -L 120VAC- 1 PHASE - 60HERTZ GDL F1 10 AMP 125V, 10kA IR To- PB1 0 0 3 PHOTOELECTRIC SENSOR (FIELD MOD) TB -N TB -2 RI --11 -0 4 6 10 1 TR13 5 0�0 V T.O. 30 MIN. DELAY A2 RELAY 1 DPDT, 8 PIN, ON -OFF INDICATION, 120VAC COIL TIME RELAY 1 OFF DELAY • ADJUSTABLE SET TO 30 MIN. CONTACTOR 1 4 N.O. 1 /2HP CONTACTS, 120VAC COIL A2 CONTACTOR 2 O • 4 N.O. 1 /2HP CONTACTS, 120VAC COIL CONTACTOR 3 4 N.O. 1 /2HP CONTACTS, 120VAC COIL A2 CONTACTOR 4 O • 4 N.O. 1 /2HP CONTACTS, 120VAC COIL LIGHT 1 30MM, GREEN LED, TRANSFORMER TYPE, 120VAC INPUT. PUSH TO TEST LIGHT 2 30MM, GREEN LED, TRANSFORMER TYPE, 120VAC INPUT, PUSH TO TEST C1 2 1 O 6 7 ❑ TB -6 ❑ TB -7 C1 4 3 8 to ❑ 9 C1 6 5 10 olio ❑ 8 C1 7 11 12 0 ❑ 13 fl TB -8 TB -9 TB -10 TB -11 TB -12 TB -13 C2 2 1 -0--1 1 O 14 ❑ TB -14 15 ❑ TB -15 C2 4 0 11 3 16 ❑ TB -16 17 ❑ TB -17 C2 6 1 5 18 ❑ TB -18 19 ❑ TB -19 C2 0 1 F0 20 ❑ TB -20 21 ❑ TB -21 C3 2 1 22 11 ❑ TB -22 23 ❑ TB -23 C3 4 3 24 0-11 0 ❑ TB -24 25 TB -25 C3 0110 26 27 o{10 28 ❑ TB -26 ❑ TB -27 ❑ TB -28 29 ❑ TB -29 C4 2 0 11 0 30 ❑ TB -30 31 ❑ TB -31 C4 4 3 32 E--O-11 O ❑ TB -32 33 C4 6 5 34 35 ❑ TB -33 ❑ TB -34 ❑ TB -35 C4 8 11 7 36 ❑ TB -36 37 ❑ TB -37 DESIGNED: PROJECT MNUDER L� "'McFARLAN, , K. MADDEN Drywr.N%47WtY �74�Ia� D. LE B. ISLER CHECKED C. REYNOLDS RECOMMENDED: w1 IBS N0: C,O - 432692/432721 RETURN/MTh - CONTRACT NO: IDMUS 03 /0e C00130007 WALE AS NOTED ONE INCH AT FULL SIZE I �• 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO REVIEWED FOR CODE COMPLIANCE E NEPA 70 APR - 3 2008 Oty Of Tukwila B ILDIN M IeN. RECEIVED C1TY OF TUKWILA MAR 2 4 2008 PERMIT CENTER METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC AND SOUTH BASE EXHAUST FAN CONTROLS SCHEMATIC DATE MAY 2007 EXHAUST FANS CONTROL PANEL EQUIPMENT SCHEDULE ITEM NO. QTY TAG DESCRIPTION DESIGN BASIS 100 1 21 "X21" BACK PANEL, PAINTED STEEL HOFFMAN A24P24 101 1 F1 IEC FUSIBLE TERMINAL BLOCK ALLEN BRADLEY 1492 -H5 102 1 F1 IEC FUSE BLOCK END BARRIER ALLEN BRADLEY 1492 -N37 103 1 F1 FUSE, GLASS, MINITURE, 10 AMP FERRAZ SHAWMUT GDL10 104 1 81 RELAY SOCKET, 8 PIN, DIN RAIL MOUNT ALLEN BRADLEY 700 -HN100 105 1 R1 GENERAL PURPOSE 8 -PIN RELAY, DPDT, 120VAC COIL, 10A CONTACTS ALLEN BRADLEY 700- HA32A1 106 1 TR1 RELAY SOCKET, 11 PIN, DIN RAIL MOUNT ALLEN BRADLEY 700 -HN101 107 1 TR1 MULTI - FUNCTION TIMER, DPDT, 100- 240VAC CONTROL ALLEN BRADLEY 700- HR52TA17 108 1 C1,C2,C3,C4 IEC CONTACTOR, 4 POLE, 120VAC COIL ALLEN BRADLEY 100- C12D400 109 1 TB IEC TERMINAL BLOCK, 22 -10AWG WIRE, 30A, 600V ALLEN BRADLEY 1492 -W4 110 1 TB IEC TERMINAL BLOCK END BARRIER ALLEN BRADLEY 1492 -EB3 111 1 IEC TERMINAL BLOCK END ANCHOR ALLEN BRADLEY 1492 -EA35 112 1 PB1 PUSH - BUTTON, 30MM, FLUSH, BLACK ALLEN BRADLEY 800T -A2A 113 1 L1,L2 PILOT LIGHT, PUSH TO TEST, TRANSFORMER, GREEN LED LAMP ALLEN BRADLEY 800T- PTH16G 114 1 24 "X24 "X6" HINGED DOOR NEMA TYPE 4 ENCLOSURE HOFFMAN A24H24ALP NOTES 1. CONTROL PANEL DESIGNED USING THE DEVICES LISTED IN THE EQUIPMENT SCHEDULE. EQUAL COMPONENTS APROVED BY THE PROJECT REPRESENTATIVE MAY BE USED. RECEk CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE Imms vu, DESIGNED: L. McFARLAND D. MAI ABLE PROJECT IAMAGER: K. MADDEN / APPROVED: B. 1SLER J� SCALE NT CHECKED: C. REYNOLDS IBS NO 432692/432721 ONE INCH AT FULL SIZE 1 I 1 IF NOT ONE INCH, SCALE ACCORDINGLY RECOMMENDED: CONTRACT NO: D. CRIPPEN X c— C00130007 SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC AND SOUTH BASE EXHAUST FAN CONTROLS EQUIPMENT SCHEDULE DATE MAY 2007 DRAWING NO: E6.03 SHEET NO: OF 9 53 7 -EF -9 PER DRAWING 1 M1.O1 REMOVE EXISTING EQUIPMENT PER DRAWING 1 M1,01. REMOVE EXISTING EQUIPMENT CURB ATLANTIC BASE FUEL /WASH BUILDING PARTIAL ROOF PLAN SCALE: 1 /2" = 1.-0" 1 M1.01 O z SIMILAR FANS WITH NEW EQUIPMENT CULL ATLANTIC BASE 21 - EF5 -02 21 -EF -29 PLAN 1 M1.03 PLAN 1 M1.03 SOUTH BASE EF -106 EF -108 EF -109 PLAN 2 M1.03 PLAN 2 M1.03 PLAN 2 M1.03 (COMBINED W /STACK Dium. 5/2 S4.01) NOTE 1 21 -EF -2A PER DRAWING 1 M1.03 COVER NEW PREFABRICATED EQUIPMENT CURB WITH 16 GA GALVANIZED STEEL SHEET AND X" CDX PLYWOOD lLQg: 1. PROVIDE CURBS SIZED PER MANUFACTURER'S RECOMMENDATIONS ATLANTIC BASE MAINTENANCE BUILDING PARTIAL ROOF TYPICAL PLAN n SCALE: 1/2" = 1' -0" 1 M1.03 1 " (TYP) 3" ALL AROUND Y4" STEEL PLATE ROOF CLOSURE PLATE DETAIL �1 SCALE: NONE - 4" MIN 4" MIN Ya"DIA X 1)fi" MIN EMBEDMENT EXPANSION ANCHORS U� O 0 0 0 0 0 0 mz0 a .°L O 0 0 0 0 0 0 r --, r. i • . O 0 0 • D •JI D 0 0 0 1 B • 0 0 O 0 O 0 O 0 • ®.A 0 0 • J. D D • 0 0" 0 O 0 0 P ® N T, MAINTENANCE BUILDING KEY PLAN SCALE: 1/64" = 1' -0" FUEL /WASH BUILDING KEY PLAN SCALE: 1/64" = 1' -0" REMOVE FAN CURB INSTALL NEW ROOFING MEMBRANE TO MATCH EXISTING, EXTEND OVERLAP AS SHOWN INSTALL NEW INSULATION & COVERBOARD TO MATCH EXISTING "tom N4:v-. •-. a•-•-.-._.:.-.-4:4!4:•- a .-a.-.-.-r.-4,74M4-.-•747.47v.- .-r.-._.__. _•-•-•-._v.-.-._ ._i • :: n EXISTING OPENING ROOF CLOSURE SECTION SCALE: NONE • � 'x t EXISTING COVERBOARD f. E XISTING rHFRNA: INSULATION — — = XIS TING CONCRETE ROOF DECK RECEi S EJ CITY OF TUKWILA CURB CLOSURE SECTION SCALE: NONE - MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE 3,49 DESIGNED: Y FARJO DRAWN: B FARISS— BATSMAN D CRIPPEN PROJECT MANAGER: K W■DODENirr APPROVED: B ISLER IBS NO: 432692 & 432721 CONTRACT N6 AS NOTED C00130007 ONE INCH AT FULL SIZE 1" IF NOT ONE INCH, SCALE ACCORDINGLY 571E LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE FUEL /WASH & MAINTENANCE BUILDINGS PARTIAL PLANS & DETAILS DATE MAY 2007 DRAWING NO: 1 A4.01 SHEET 00: OF 10 53 7 -EF -2 ELEC -R CA_ FOL;•FM: N T ROOF PLAN SCALE: 1/8"=1'-0" GENERAL NOTES: 1. PROTECT EXISTING ROOFING DURING CONSTRUCTION PER SPECIFICATION SECTION 07552. 2. ALL EQUIPMENT AND MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL CODES AND ORDINACES. -- 7 -EF -8 O E1VED FOR CODE OMP NEC E N 70 AP IR - 3 ZOOS ' ,• Of Tukwila !IVI I AlwAi KEY NOTES: REMOVE EXISTING EXHAUST FAN AND BACKDRAFT DAMPER. EXISTING CURB TO REMAIN IN PLACE. MODIFY EXISTING CURB PER DETAIL 1/1M5.01 INSTALL NEW EXHAUST FAN WITH FLASHING PER DETAIL 2/A5.01. PROVIDE SHEET METAL ADAPTERS BETWEEN THE EXISTING CURBS AND NEW EXHAUST FANS TO ENSURE A WATER AND AIR TIGHT FIT. REMOVE EXISTING GRAVITY VENTILATOR AND CURB. INSTALL NEW EXHAUST FAN, BACKDRAFT DAMPER AND CURB OVER OPENING PER DETAIL 2/1M5.01. REMOVE EXISTING EXHAUST FAN EF -12 AND BACKDRAFT DAMPER. REMOVE EXISTING CURB AND PLATE OFF PER PLAN 1 /1A4f4tCEIVED CITY OF TDKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP•D DATE MOONED: J. TURNER PROJECT MANAGER:/ K. MADDEN ` APPROVED- B. ISLER us NO: 432692/432721 ■mc REQUEST: — i/a " =1' -D" ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY STE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE FUEL AND WASH BUILDING ROOF PLAN DATE MAY 2007 DRAWING NO: 1 M1.01 SHEET NO, OF 11 53 (6J B/1 M3.01 SIDE WALL EXHAUST FAN 7 -EF -14 8/1M3.01 MAIN LEVEL PARTIAL FLOOR PLAN SCALE: 1/4"= ' - -0" EXISTING COMPRESSORS GENERAL NOTES: 30x30 UP TO 7 -EF -12 ON ROOF MEZZANINE LEVEL PARTIAL FLOOR PLAN SCALE: 3/6"=1.--o" 1. ALL EQUIPMENT AND MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL CODES AND DRDINACES. KEY NOTES: REMOVE EXISTING EXHAUST FAN. EXISTING DUCTWORK AND EXHAUST LOUVER TO REMAIN IN PLACE. SEE DRAWING 1M3.01 FOR NEW FAN INSTALLATION. 24x16 EG -1 2310 CFM. (4 TYP) AREA OF WORK O O O 0 0 0 1 M3.01 REVIEWED FOR ODE COMP ANCE NFPA 70 APR - 3 2008 Oty Of Tukwila f3ILD ' IAN. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER KEY PLAN No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: 416 J. BICKERSTAFF CHECKED: R. OUIST RECOMMENDED: q,{1'r D. CRIPPEN yCY v PROJECT MANAGER: K. MADDEN/ APPROVED: B. ISLER IBIS NO: 432692/432721 mot REQIASF - CONTRACT NO: C00130007 SCALE: AS NOTED ONE INCH AT FULL SIZE I• IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION N0: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE FUEL AND WASH BUILDING PARTIAL PLANS DATE MAY 2007 DRAWING 40: 1 M1.02 SHEET NO: OF 12 53 GENERAL NOTES: 1. PROTECT EXISTING ROOFING DURING CONSTRUCTION PER SPECIFICATION SECTION 07552. 2. ALL EQUIPMENT AND MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL CODES AND ORDINACES. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER KEY NOTES: REMOVE EXISTING EXHAUST FAN AND BACKDRAFT DAMPER. EXISTING CURB TO REMAIN IN PLACE. MODIFY EXISTING CURB PER DETAIL 1/1M5.01, INSTALL NEW EXHAUST FAN WITH FLASHING PER DETAIL 2/A5.01. PROVIDE SHEET METAL ADAPTERS BETWEEN THE EXISTING CURBS AND NEW EXHAUST FANS TO ENSURE A WATER AND AIR TIGHT FIT. REMOVE EXISTING EXHAUST FAN AND BACKDRAFT DAMPER. EXISTING CURB TO REMAIN IN PLACE. INSTALL NEW EXHAUST FAN WITH FLASHING PER DETAIL 1/1M5.01 AND DETAIL 1/A5.01. REMOVE EXISTING EXHAUST FAN. EXISTING CURB TO REMAIN IN PLACE. INSTALL NEW FLASHING. INSTALL NEW EXHAUST FAN AND EQUIPMENT CURB PER DETAIL 1/1M5.02. REMOVE EXISTING EXHAUST FAN AND EQUIPMENT CURB. EXISTING ROOF PENETRATION AND CURB TO REMAIN IN PLACE. INSTALL NEW FLASHING. INSTALL NEW EXHAUST FAN AND EQUIPMENT CURB PER DETAIL 2/1M5.02. REMOVE EXISTING EXHAUST FAN AND BACKDRAFT DAMPER. EXISTING CURB TO REMAIN IN PLACE. INSTALL NEW FLASHING. INSTALL NEW EXHAUST FAN AND EQUIPMENT CURB PER DETAIL 311M5.01 AND PLAN 3/1A4.01. — WORK AREA r L KEY PLAN No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: `5704/ Fos H /o/o -1 R. OUIST RECOMMENDED: AO- PROJECT D. CRIPPEN AO- PROJECT MANAGER: K. MADDEN /40# APPROVED: !i • B. ISLER JJ IBIS NO 432692/432721 MAX ROMS, - CONTRACT NO: C00130007 SCALE: 3/32 " =1' -0" ONE INCH AT FULL SIZE • 1 ' IF NOT ONE INCH. SCALE ACCORDINGLY SITE LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MAINTENANCE BUILDING ROOF PLAN DATE: MAY 2D07 DRAWING NO 1 M1.03 SHEET NO OF 13 53 39" (REF) 66" (REF) EXTEND LUBE LINES TO EXTERIOR OF FAN CABINET. TERMINATE WITH ZERK FITTINGS IN AN ACCESSIBLE LOCATION. 11 1 EXIS ING COM RES o SORS /� SECTION SCALE: 3/8 "= 1' --0" 1M1.02 SECTION SCALE: 3/4 " =1' -0" - -- INSTALL BLANK OFF FLANGE (4 SIDES), SECURE TO EXISTING FAN CABINET W/ FASTENERS PER MANUFACTURERS RECOMMENDATIONS CENTER NEW EXHAUST FAN 7 -EF -14 INSIDE EXISTING CABINET PRESSURE WASH EXISTING BACKDRAFT DAMPERS PRIOR TO INSTALLING FAN SEE EQUIPMENT SCHEDULE 24x16 EG -1, (TYP 4) EXISTING LIGHTING FIXTURE (TYP) 11' -0" • EXHAUST FAN 7 -EF -12 ELEV 22' -6 NOMINAL POC FOR 30x30 RISER DUCT EXHAUST FAN 7 EF 14 PRESSURE WASH FAN CABINET AND SCREENED OPNG. EXISTING FAN CABINET TO REMAIN EAST WALL ELEVATION SCALE: 3/8 " =1' -0" FINISHED FLOOR RECEIVED CITY OF TUKWIL4 MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DISIGNEID. 7L R. QUIST RECOMMENDED: mom 11/9/ O'1 D. CRIPPEN B. ISLER 196 NO: 432692/432721 Mat REQUEST: - tONiRACT NO: C00130007 WALE AS NOTED ONE INCH AT FULL SIZE I. 1 IF NOT ONE INCH. SCALE ACCORDINGLY SRE LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE ELEVATION AND SECTIONS DATE: MAY 2007 ORAWING NO: 1 M3.01 SHEET NO: OF 14 53 ROOF MOUNTED CENTRIFUGAL EXHAUST FAN - DUCTWORK ROOF MOUNTED CENTRIFUGAL EXHAUST FAN /-MESH BIRDSCREEN r- TYP ROOF EXHAUST FAN ON EXISTING CURB DETAIL (T SCALE: NTS EXISTING BUILT -UP ROOF DUCTWORK TYP ROOF EXHAUST FAN WITH NEW CURB DETAIL SCALE: NTS -- SECURE FAN TO CURB WITH 1 1/2" LONG FASTENERS AT 12" OC (MINIMUM 2 PER SIDE, AS REQUIRED) EXISTING BUILT -UP ROOF SEE EQUIPMENT SCHEDULE EXISTING ROOF CURB SEE NOTE AND n(TN\ A5.01 A5.01 BACKDRAFT DAMPER AS SPECIFIED. NOTE; BUILD -UP CURB W/ SPACER AS REQUIRED TO ACHIEVE A MINIMUM HEIGHT OF 8" ABOVE FINISHED ROOF. MESH BIRDSCREEN SECURE FAN TO CURB WITH 1 1/2" LONG FASTENERS AT 12" OC (MINIMUM 2 PER SIDE, AS REQUIRED) 8" PREFABRICATED ROOF CURB, SEEK-73's\ 45.01 SEE EQUIPMENT SCHEDULE SEE ARCHITECTURAL DRAWINGS FOR ROOF OPENING BACKDRAFT DAMPER AS SPECIFIED. BIRD SCREEN PLAN EXHAUST FAN FLEXIBLE CONNECTION STAINLESS STEEL SCREWCLAMP (TYP) 10 "0 GALVANIZED STEEL CURB FLASHING, STAINLESS STEEL SEE A5.01 EXISTING 29 "x29 "x 4 "H CURB, RAISE PER A5.01 EXISTING DUCTWORK, SEE MECHANICAL FASTENERS (TYP) EXISTING DUCTWORK 7' -0' 1M5.02 EXHAUST FAN 21 -EF -2A DETAIL SCALE: 1"=1' -0" 1 M1 .03 1 1 "0 DISCHARGE DUCT, ALUMINUM ALLOY (14 GAUGE) TRANSITION DUCT, ALUMINUM ALLOY 11 -3/4 "x 1 1 " TO 10" DIA. (14 GAUGE) BACKDRAFT DAMPER W/ FLANGED CONNECTIONS ELEVATION EXISTING BUILT -UP ROOF TYPICAL DUCT CONNECTION DETAIL SCALE: NTS EXHAUST FAN NEW 8 "H EQUIPMENT CURB, SEE n & n 1M5.03 1A4.01 ELEV 24' -3 NOMINAL DRAIN HOLE W/ REMOVABLE PLUG EXISTING ROOF CURB 16 GAUGE PLATE SIZED FOR DUCTING TO EXHAUST FAN RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DES CANED: J. TURNER DRANM: - J. BICKERSTAFF PROJECT MANAGER: K. MADDEN APPROVED: B. ISLER SCALE: AS NOTED CHECKED: MIS NO 432692/432721 R. QUIST ■omc AIDI.FSf, - RECODUENDEOE CONTRACT NO D CRIPPEN ' C00130007 ONE INCH AT FUU SIZE 1• IF NOT ONE INCH, SCALE ACCORDINGLY SfTE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MECHANICAL DETAILS DATE: MAY 2DC7 DRAWING NO 1 M5.01 SHEET N0: OF 15 53 BIRD SCREEN EXHAUST FAN FLEXIBLE CONNECTION STAINLESS STEEL SCREWCLAMP (TYP) 8 "0 GALVANIZED STEEL - CURB FLASHING, STAINLESS STEEL SEE PLAN DISCHARGE DUCT A5.01 EXISTING 21 "x21 "x 7 "H CURB EXISTING DUCTWORK, SEE 1M5.01 7' -0" BIRD SCREEN 9 "0 DISCHARGE DUCT, ALUMINUM ALLOY (14 GAUGE) TRANSITION DUCT, ALUMINUM ALLOY 10 -1/8 "x 10" TO 8" DIA. (14 GAUGE) BACKDRAFT DAMPER W/ FLANGED CONNECTIONS ELEVATION EXHAUST FAN 21- EF5 -02 DETAIL (Th SCALE: 1"=1. -0" 1M1.03 NOTE. DISCHARGE DUCT AND STACK HEAD, ALUMINUM ALLOY (14 GAUGE), WELDED CONSTRUCTION. SECTION SCALE: 1- 1/2"=1 ' -0" - 5/8 "DIA. SS BOLT & WASHER 1 1/2 "DIA. NON - METALIC SPACER, 1/2" THICK LOCK NUT & WASHER TACK WELDED TO DISCHARGE DUCT 2 EXHAUST FAN NEW 8 "H EQUIPMENT CURB, SEE & 1M5.03 1A4.01 ELEV 24' -3 NOMINAL. DRAIN HOLE W/ REMOVABLE PLUG PLAN EXHAUST FAN FLEXIBLE CONNECTION STAINLESS STEEL SCREWCLAMP (TYP) 10 "0 GALVANIZED STEEL 1 1 "0 DISCHARGE DUCT, ALUMINUM ALLOY (14 GAUGE) TRANSITION DUCT, ALUMINUM ALLOY 11-3/4"x 1 1 " TO 10" DIA. (14 GAUGE) BACKDRAFT DAMPER W/ FLANGED CONNECTIONS CURB FLASHING, STAINLESS STEEL SEE EXISTING 27 "x27 "x 7 "H CURB EXISTING DUCTWORK, SEE A 1M5.01 ELEVATION EXHAUST FAN 21 -EF -29 DETAIL SCALE: 1"=1' -0" 1 M1.03 DRAIN HOLE W/ REMOVABLE PLUG EXHAUST FAN NEW 8 "H EQUIPMENT CURB, SEE / ' 1 & 0,7* 1M5.03 1A4.01 ELEV 24' -3 NOMINAL RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE S/14/o -1 DESIGNED J. TURNER DRAWN J. BICKERSTAAI F CHECKED: R. QUIST RECOMMENDED: D CRIPPEN PROJECT MANAGER K MADDEN/ APPROVED: 6 8 ISLER V 81S NO: 432692/432721 Mow : CONTRACT NO: SCALE: AS NOTED C00130007 ONE INCH AT FULL SIZE 1- IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MECHANICAL DETAILS DATE: MAY 2007 DRAWING NO: 1 M5.02 SHEET NO: OF 16 53 12 GA. STEEL CURB FLASHING DIM. A DIM. B 1/20 (TYP. 4) PLAN EQUIPMENT CURB DETAIL SCALE: 2"==-1' -0" 1M5.01 1 M5.02 A4.01 CLUE; VIBRATION SPRING MOUNT (TYP 4), SEE DETAIL2 SEE TABLE-A FOR SPRING MOUNT DIMENSIONS. CURB FRAMING, FLASHING AND ATTACHMENT SEE 2/A5.02 VIBRATION SPRING MOUNT W/ SEISMIC SNUBBER VIBRATION MOUNT DETAIL -2- SCALE: NTS TABLE A FAN NO. "A" DIMENSION "B" DIMENSION 21 -EF5-02 13 1/2" 12" 21 -EF-29 16" 21 7/8" 21 -EF-2A 23 3/8" 32 1/4" NOTE: 1. DIMENSIONS SHOWN ON TABLE -A ARE FOR EXHAUST FANS LISTED ON DRAWING 1M6.01. RECEIVED CITY OF TUKINILA MAR 2 4 2008 PERMIT CENTER REVISION BY APP.() DATE DESIGNED: J. TURNER DRAWN: 0646 J. BICKERSTAFF CHECKED:. R. QUIST jee RECOMMENDED: A D CRIPPEN PROJECT ONAGER: K MADDEN / APPROVED: B ISLER ' OS NO: 432692/432721 *OW REQUEST: CONTRACT NO: C00130007 SCALE: AS NOTED ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MECHANICAL DETAILS DATE: MAY 20D7 DRAWING NO: 1 M5.03 SHEET 50. OF 17 5,3 EXHAUST FAN SCHEDULE MARK AREA SERVED CFM FAN SPEED (RPM) EXT SP (IN WC) dBA1 MOTOR DRIVE ASSEMBLY EXISTING (LOS) NEW WEIGHT (LBS) NEW EQUIP HEIGHT BASIS OF DESIGN EXISTING CURB MOTOR HP BHP VOLT PH HZ SIZE HT. 7 -EF -1 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 264„ 6" 7 EF 2 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 2 6» 7 -EF -3 FUEL WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 2 6" 7 -EF -4 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 2 �" 6» 7 -EF -5 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 2 6» 7 -EF -6 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 26}" 6» 7 -EF 7 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER. BIRDSCREEN AND ODP MOTOR 264" 6» 7 -EF -8 FUEL -WASH BUILDING GENERAL EXHAUST 2030 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 2 �" 6'• 7 -EF -9 FUEL WASH BUILDING TOILET EXHAUST 565 1140 0.375 53 1 6 / 0.06 120 1 60 DIRECT 45 43 282 GREENHECK G -101 -B WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 1 7 „ 7- -EF -10 FUEL -WASH BUILDING GENERATOR ROOM EXHAUST 225 1050 0.125 45 1 40 / 0.02 120 1 60 DIRECT 25 26 232 GREENHECK G -080 -E WITH BACK DRAFT DAMPER. BIRDSCREEN AND ODP MOTOR 184" » 7 -EF -11 FUEL WASH BUILDING SERVICE ROOM EXHAUST 225 1050 0.125 45 1 40 / 0.02 120 1 60 DIRECT 25 26 232 GREENHECK G -080 -E WITH BACK DRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 184" 5» 7 -EF -12 FUEL -WASH BUILDING SERVICE EQUIP. ROOM EXHAUST 9240 465 0.5 64 2 1.5 480 3 60 BELT 300 385 472 GREENHECK GB- 330 -20 WITH BACK DRAFT DAMPER. BIRDSCREEN AND ODP MOTOR 32" 5 » 7 -EF -14 FUEL -WASH BUILDING SIDE WALL FAN 35800 680 0.25 83 7 1/2 / 6.0 480 3 60 BELT 600 590 1303 GREENHECK SBC- 3L54 -75 WITH TEFC MOTOR 21 -EF -2A MAINTENANCE BUILDING BATTERY ROOM EXHAUST 1200 1760 0.5 63 1 2 / 0.28 480 3 60 BELT 100 140 402 GREENHECK 110 SWB SERIES 100, WITH ODP MOTOR, TYPE B SPARK RESISTANT CONSTRUCTION AND EPDXY FINISH 29" 4" 21 - EF5-02 MAINTENANCE BUILDING AXLE LIFT PIT EXHAUST 480 899 0.5 58 1 4 / 0.09 120 1 60 BELT 100 _ 120 502 GREENHECK SFB -9, WITH ODP MOTOR, TYPE B SPARK RESISTANT CONSTRUCTION 22" 21 " 21 -EF -14 MAINTENANCE BUILDING JANITOR'S CLOSET EXHAUST 90 1050 0.25 45 1 40 / 0.02 120 1 60 DIRECT 25 26 232 GREENHECK G -080 -E WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 20" 6" 21 -EF -15 MAINTENANCE BUILDING ELEVATOR MECH. ROOM EXHAUST 140 1050 0.25 45 1 40 / 0.02 120 1 6C DIRECT 25 26 232 GREENHECK G -080 -E WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 20" 6" 21 -EF-16 MAINTENANCE BUILDING EMERGENCY GENERATOR EXHAUST 2010 860 0.25 59 1 4 / 0.21 120 1 60 DIRECT 75 81 302 GREENHECK C -170 -C WITH BACKDRAFT DAMPER. BIRDSCREEN AND ODP MOTOR 25" 6" 21 -EF-17 MAINTENANCE BUILDING COMPRESSOR ROOM EXHAUST 4320 304 0.5 64 3 4 / 0.39 480 3 60 BELT 350 365 472 GREENHECK GB -330 -7 WITH BACKDRAFT DAMPER. BIRDSCREEN AND ODP MOTOR 34" 8" 21 -EF -29 MAINTENANCE BUILDING PAINT CLEAN -UP BOOTH EXHAUST 1250 1810 0.5 63 1 2 / 0.30 480 3 60 BELT 140 140 402 GREENHECK 110 SWB SERIES 100, WITH ODP MOTOR, TYPE B SPARK RESISTANT CONSTRUCTION 36x40" 7" 1. NOISE RATING PER ARI 270. 2. HEIGHT ABOVE ROOF: FUEL & WASH BLDG ROOF ELEV = 22' -6 NOMINAL, MAINTENANCE BUILDING ROOF ELEV = 24' -3 NOMINAL. (INCLUDING CURB). 3. HEIGHT ABOVE FINISHED FLOOR. GRILLES /REGISTERS /DIFFUSER SCHEDULE MARK CFM IN) SIZE (IN) ( NECK (IN) SIZE(IN CRITERIA (MAX) MANFACTURE AND MODEL REMARKS NOISE CRITERIA (NC) TP (IN WG) EG -1 2310 24x16 22x14 35 0.15 TITUS 50R W/ 1 "x1 "x1" ALUMINUM CORE GENERAL NOTES: 1. VERIFY SIZES OF ALL EXISTING ROOF CURBS BEFORE ORDERING NEW EXHAUST FANS. 2. WHERE THERE ARE DIMENSIONAL DIFFERENCES, PROVIDE SHEET METAL ADAPTERS BETWEEN THE EXISTING CURBS AND NEW EXHAUST FANS TO ENSURE A WATER AND AIR TIGHT FIT. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: 145 J. B1CKERSTAFF CHECKED, R. QUIST PROJECT MANAGER: K. MADDEN / 4 APPROVED: AS NOTED B. ISLER '/ ✓' T� ND 432692/432721 ONE INCH AT FULL SIZE I 1 I IF NOT DNE INCH, SCALE ACCORDINGLY RECOMMENDED.. D. CRIPPEN ✓"` CONTRACT NO C00130007 SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE E XHAUST FAN REPLACEMENT ATLANTIC BASE EQUIPMENT SCHEDULE DATE MAY 2007 DRAWING 1 M6.01 SHEET NO: OF 1B 53 No. Y 4' GRAVITY VENTILATOR (6 FYP) 7-EF- 1 ELECTRICAL EQUIt'MENT 7 -EF -7 7 -EF -6 { 3/4" CONDUIT DOWN, TYP FOR ALL COND IT PI -5,9 L2 -23, STAIRS 7 -EF -9 7 -EF -11 P1 -2 7 EF 12 7 -EF -8 P1- , `7 39 7 -EF -10 LEGEND: MOTOR DISCONNECT SWITCH COMBINATION MOTOR STARTER CONDUIT DOWN ROOF PLAN SCALE: 1/8 " =1 -0" EP EXHAUST FAN MOTOR THERMAL MOTOR SWITCH - - - CONSTRUCTION NOTES: DISCONNECT EXISTING FAN MOTOR FOR REMOVAL. CONNECT NEW FAN MOTOR TO NEW DISCONNECT SWITCH OR COMBINATION STARTER. TYPICAL 11 PLACES. INSTALL NEW COMBINATION MOTOR STARTER, CONDUIT AND WIRING, SEE DRAWINGS E5.01 DETAIL 1 AND 2 E6.06 DISCONNECT EXISTING FAN MOTOR. REMOVE WIRING AND CONDUIT BACK TO PANEL "EB" CKT #3. CONNECT NEW EXHAUST FAN 7- EF -12, TO NEW COMBINATION STARTER. DISCONNECT EXISTING DAMPER MOTOR FOR REMOVAL. INSTALL THERMAL MOTOR SWIITCH TYPE NEMA 4, WITH HANDLE GUARD AND PADLOCK CAPABILITY. INSTALL ASSOCIATED CONDUIT AND WIRING. (TYP 9 PLACES) INSTALL NEW SPECIFICATION GRADE GFCI OUTLET IN "FD" CAST IRON DEVICE BOX WITH WEATHERPROOF WHILE IN USE COVER. INSTALL CONDUIT AND WIRING. (TYP 6 PLACES) RECONNECT EXISTING GRAVITY VENTILATOR DAMPER MOTOR. TYPICAL 4 PLACES RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER REVISION BY APP'D DATE DESIGNED: L McFAR D tivN: / l r-r1-2C D. LE CHEMED C. REYNOLDS RECOMMENDED: D. CRIPPEN PROJECT DEN K. MAD APPROVED: B. ISLER IBIS NO: 432692/432721 sow IEpR.srt - CONiRACf NO C00130007 =ALE 1/8"=1.-0" DNE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY King County SITE LOCATION NO: Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT FUEL AND WASH BUILDING ROOF PLAN DATE MAY 2007 DRAWING NO: 1 E1.01 SHEET NO: OF 19 53 0- r I 7 -EF -14 � t 1 TO PNL "PF- CKT #3" L ADD CONTROL WIRING 1 #1" GRS CONDUIT TO EXISTING CONDUIT I 3 #4 AWG THWN CU 1 #8 AWG CU. GROUND -I- E2.01 PANEL "PF" PANEL "P1 PANEL "P5" AUTO MATIC TRANSFER SWITCH PANEL EB ' -Box STARTER STARTER EF -12 - r 1 #1 -1/2" GRS CONDUIT 4 #2 AWG THWN CU 1 #8 AWG CU. GROUND (iD PANEL EL PANEL E2 TRANSFORMER REPLACE EXISTING PHOTOELECTRIC SENSOR. USE LONG RANGE DIFFUSE SENSOR "AB 42GRP -9043, BANNER Q45BW13DX" OR APPROVED EQUAL. (TYPICAL 2 PLACES) J T T5 TRANSFORMER T1 LEGEND: DISCONNECT SWITCH COMBINATION MOTOR STARTER CONDUIT DOWN EXHAUST FAN MOTOR TRANSFORMER BATTERY CHARGER 19 CONSTRUCTION NOTES: DISCONNECT EXISTING FAN MOTOR. CONNECT NEW FAN MOTOR TO NEW COMBINATION MOTOR STARTER. INSTALL NEW COMBINATION MOTOR STARTER, CONDUIT AND WIRING. REMOVE EXISTING MOTOR STARTERS FOR EF -10 AND EF -11. REMOVE ASSOCIATED CONDUIT AND WIRE. INSTALL NEW PANEL "P1" INSTALL NEW TRANSFORMER "Ti", 30KVA, 480- 208Y/120, NEMA TP1. CONNECT CONDUIT AND WIRE AS SHOWN. REMOVE EXISTING MOTOR STARTER EF -12, ASSOCIATED CONDUIT AND WIRE. INSTALL NEW 80 AMP, 3 POLE, CIRCUIT BREAKER IN MDP -2. CONTRACTOR SHALL SUPPLY ALL MATERIALS AND BUSSkteSIVEDLLATION OF BREAKER. CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: L McFARLAND - PROJECT MANAGER: K. MADDEN / / 4 IDwvo-s 6/13/� APPROVED: B. ISLER 6 CHECKED. OS NO �1 X432692/432721 C. REYNOLDS CA 1 . - RECONYENDED: D CRIPPEN CONTRACT NO: C000130007 SCAB 1/8 " =1' -0" ONE INCH AT �FULL L SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT FUEL AND WASH BUILDING FIRST FLOOR PLAN AND SECOND FLOOR MEZZ DATE. MAY 2007 DRWIMNG NO: 1 E1.02 SHEET NO, OF 20 53 - I F 7' x rz LJ Co) P2 -44 e r H, 0 I —71. EXISTING STARTERS rJ I P2 -44 GFCI WP 21 -EF--29 L•� v� J GFCI WP P7 -30 a PA -12 GFCI wp P2 -25 L_l 21- EF5 -02 THERMOSTAT IN ROOM 122 THERMOSTAT IN ELEVATOR MACHINE ROOM GFCI WP P1 -33 THERMOSTAT IN ROOM 123 F -17 21 -EF -15 21 -EF -16 L LEGEND: MOTOR STARTER DISCONNECT SWITCH a COMBINATION MOTOR STARTER CONDUIT DOWN 0 EXHAUST FAN MOTOR CONSTRUCTION NOTES: DISCONNECT EXISTING FAN MOTOR FOR REMOVAL. CONNECT NEW FAN MOTOR TO NEW DISCONNECT SWITCH OR STARTER. INSTALL NEW NEMA 4X COMBINATION MOTOR STARTER, CONDUIT AND WIRING. SEE DRAWING E5,01 DETAIL 2. INSTALL MOTOR DISCONNECT, 2DA SNAP SWITCH MOUNTED IN CAST 'FD' DEVICE BOX WITH CAST LOCKABLE LEVER ACTIVATED COVER. INSTALL CONDUIT AND WIRING. SEE DRAWING E5.01 DETAIL 1 INSTALL NEW NEMA 4X STAINLESS NON -FUSED MOTOR DISCONNECT SWITCH, CONDUIT AND WIRING. SEE DRAWING E5.01, DETAIL 1 INSTALL NEW OVERLOAD HEATERS IN EXISTING STARTER RATED FOR THE FLA OF NEW FAN MOTOR. INSTALL NEW 20A SPECIFICATION GRADE GFCI OUTLET IN "FD" CAST IRON DEVICE BOX WITH WEATHERPROOF WHILE IN USE COVER. INSTALL CONDUIT AND WIRING. (TYP 5 PLACES) RECEIVED CITY OF TUKWILA 0 J KEY PLAN MAR 2 4 2008 wtE'.:: SIT CENTER d cr 0 No. 1 REVISION BY APP'D DATE DESIGNED: PROJECT MANAGER: L. MCFARL,4ND K. MADDEN APPROVED: LE B. ISLER „L. I I Bons a /I3/Ob' IBIS NO C, -432692/432721 C. REYNOLDS yaw[ A[aIASF - RECOMMENDED: CONTRACT NO: 0 CRIPPEN ) COD130007 SCM . 3/32 " =1' -0" ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MAINTENANCE BUILDING ROOF PLAN DATE: MAY 2007 DRAWING NO: 1 E1.03 SHEET NO: DF 21 53 BAY 19 101 PAINTING BAY 18 BAY 17 II 105 BATT,'_s HOP I 103 BRAKE SHOP 01102) STEAM CLEANING BAY 16 PUMP ROOM PNL 'P7" ELECTRICAL SHOP ELECTRICAL SHOP ELECTRONICS I STEAM CLEANING 1188 ELECTRICAL SHOP 171''' ELEC CHIEF O-HR Fl- 1 PAINT PREPARATION AREA T PARTS STORAGE JANITOR BASE MACHINIST 1/ (i09) UNIT STORAGE L. I P7 -30 TO MOTOR DISCONNECT ON ROOF 21— EF5 -02 MECH CHIEF PNL "PB" PNL 'P2" /2/48 OFFICE OFFICE OFFICE N r- OFFICE COMPRESSOR ROOM IRST AID PARTS ROOM CC rte= ELEV ELECTRIC.r ROOM PNL "PA" DEMOLITION OF 6 O EXISTING STARTERS LEGEND: MOTOR STARTER DISCONNECT SWITCH COMBINATION MOTOR STARTER -D CONDUIT DOWN EXHAUST FAN MOTOR THERMAL MOTOR SWITCH WITH HANDLE GUARD AND PADLOCK CAPABILITY. CONSTRUCTION NOTES: REMOVE EXISTING MOTOR STARTER. REMOVE EXISTING THERMOSTAT. INSTALL NEW THERMOSTAT. RUN UP TO COMBINATION STARTER ON ROOF. REMOVE EXISTING THERMOSTAT. INSTALL NEW THERMOSTAT. RUN UP TO STARTER ON ROOF. WORK AREA RECEIVED CITY OF TUKWILA MAR 242008 PERMIT CENTER No. REVISION BY APP "D DATE I IDS 6/13/0F DESIGNED: PROJECT MANAGER: L McFARLAND K. MADDEN APPROVED. e. D. LE B. ISLER CHECKED: IBIS NO: `��,� 432692/432721 C. REYNOLDS CM1- ' SOW RmuTSe — RECOMMENDED CONTRACT NO: D CRIPPEN L 0001300007 3/32 " =1' -0" ONE INCH AT FULL SIZE If NOT ONE INCH, SCALE ACCORDINGLY SUE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MAINTENANCE BUILDING SECOND FLOOR PLAN DATE: MAY 2007 DRAWING NO: 1 E1.04 SHEET ND OF 22 5.3 OPEN TO BODY SHOP BELOW TO commnoN STARTER ON ROOF SECOND FLOOR PARTIAL PLAN SCALE: NTS No. REVISION BY ,APP'D DATE DESIGNED: L. McFARLAND MARABLE OHEGKEM C. REYNOLDS RECT3MMENDED: I DARES 6/13/ ok D CRIPPEN LEGEND: Ell MOTOR STARTER DISCONNECT SWITCH COMBINATION MOTOR STARTER -0 CONDUIT DOWN PROJECT MANAGER: SCALE 3/32"= 1 —0" OFIEJLLNZEJ K. MADDEN APPROVED: B. ISLER IIRS NO: 432692/432721 WORK PECIUMIT - CONTRACT NO: C00130007 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation CONSTRUCTION NOTES: REMOVE EXISTING STARTER DISCONNECT AND THERMSTAT, REMOVE UN—USED CONDUIT AND WIRE. INSTALL NEW THERMOSTAT. RECEIVED CITY OF TUKVVILA MAR 2 4 1[18 PERMIT CENTER METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE MAINTENANCE BUILDING SECOND FLOOR PLAN OATS MAY 2007 DRAWING NO: 1 E1.05 SHEET NO: OF 23 53 TO PANEL P5- CKT4I16 z42 EXHAUST FAN CONTROL PANEL EXHAUST FAN MOTORS CONTROLS TYP. 9 PLC. /i CONTROL PANELS LOCATION ELAVATION PLAN (A\ SCALE: N/A 1 E1.02 TO PHOTO ELECTRIC SENSORS CONSTRUCTION NOTES: REMOVE EXISTING MOTOR SWITCHES AND WIREWAY (GUTTER) REROUTE CONDUIT FROM PANEL "E2" TO PANEL "P1 ". INTTALL NEW WIRING FROM PANEL "P1 ". CONNECT WIRING TO NEW COMBINATION MOTOR STARTER FOR '7- EF -14'. SEE DRAWING 1 E1.02 FOR STARTER LOCATION. REMOVE EXISTING EXHAUST FAN CONTROL PANEL, FURNISH AND INSTALL NEW CONTROL PANEL. SEE DRAWING E6.01 E6.02 AND E6.03 FOR CONTOL PANEL DESIGN. CONNECT MOTOR, CONTROL AND PHOTO ELECTRIC CIRCUITS. INSTALL NEW WIREWAY. NEMA -12 WIRING TROUGH. INSTALL NEW 12 AWG WIRING TO 7EF -1, 7 -EF -2, 7 -EF -3, 7 -EF -4, GV -1, GV -2, AND OUTLETS. INSTALL NEW 12 AWG WIRING TO 7EF -5, 7 -EF -6, 7 -EF -7, 7 -EF -8, GV -3, CV -4, AND OUTLETS. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP.() DATE CORES SAW Oi DESIGNED: L McFARLAND GRryyN:�jlwz,��� Dl. LE PROJECT MANAGER: K. MADDEN // 7 p APPROVED: CHECKED: N/A / ✓. ONE INCH FULL SIZE B. ISLER '✓ 1 IBIS NO: I- I 432692/432721 IF NOT ONE INCH, C. REYNOLDS C WORK mount - SCALE ACCORDINGLY RECOMMENDED: u� /� CONTRACT NO: SITE LOCATION NO D. CRIPPEN W C00130007 King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC F/W BLDG PARTAIL FIRST FLOOR ELEVATION DATE: MAY 2007 DRAWING NO: 1 E2.01 SHEET NO: OF 24 53 SCL METERING FROM SCL A 11 I 11 SCL TRANSFORMER 26.4K- 480Y/277V UTILITY METERING COMPARTMENT REPIACE EXISTING 3 #6 AWG, 1 #8 AWG GROUND WITH 3#3 AWG THWN CU, 1 #8 AWG CU GROUND. PF FUFlH BUILDING 11 f GFP- 800 /3P MAIN CB WITH GROUND FAULT TRIP AND SHORT TIME OPTION. 3PH, 4W ) 250A COMPRESSOR CONTROL PANEL O 7 -AC -1 40H P 7 -AC -2 40H P SWBD PNL MDP2 800A 480/277 VOLTS, 3PH, 4W 12 ) 175A I\3 I 4 1 175A 1175A BUS BUS WASHER WASHER (4)42/0 LANE #1 LANE #2 I 16) 225A 225A TRANS. SWITCH PANEL "P6" 225A MLO 125KW STANDBY DIESEL GENERATOR 15 1\5 16 ) 100AT ) 70AT PANEL PG" 1 DOA MLO 6J mm PANEL "P6" 100A 50A MCB PANEL "LC" 225A MLO 15 PANEL 100A MLO CYCLONE EAST CYCLONE WEST PANEL "P5" 1 00A 50A MCB PANEL "PJ" 200A 200A MCB 15KALL JJ 45 y LLJJ rrn PANEL "EL" 100A MLO PANEL "E2 1 50A 150A MCB PANEL "ED" 1 00A OOA MCB 15K u".. J min 15 PANEL "EAF B" 100A 50A MCB FAIR BOX AREA PANEL "E5" 100A MW 1 rrm PANEL "ED -L1" 100A 40A MCB OPERATION$ BUILDING PANEL "P5A" 1 25A MLO PANEL "P8" 1 00A 40A MCB FUEL ISLAND RECEIVED CITY OF TUKWILA MAR 2 4 Z008 PERMIT CENTER ADDED PWR PNL & XFMR TO DIST. PNL MDP2 JDM LM 12/06 No. REVISION BY APP.!) DATE DESIGNED: PROJECT MANAGER. L. McFARLAND K. MADDEN /7 APPROVED: B. ISLER i. CONTRACT NO: I aims 6/13/ op D CRIPPEN v C001 30007 SCALE: N/A ONE INCH AT FULL SIZE 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT ATLANTIC BASE FUEL /WASH BUILDING SINGLE LINE DIAGRAM DATE: MAY 2007 DRAWING NO: 1 E6.01 SHEET NO: OF 25 53 j/. ELECTRICAL P1REL SCHEDULE PANEL PA BLDGMAINTENANCE TYPE WESTINGHOUSE WEHB 'SE56825_1T.4 -1' SURFACE or FLUSH' SURFACE MAIN BKR MLO RATING 225A, 480V DELTA, 8PH, 3W REF DWG NOW REVISION(s) AS BUILT (MFD) ENGINEER JS PELMAN (206 - 263 -3713) BASE AB DATE 2- Apr -07 LOCATION BOILER ROOM FEEDERS (3) 13 /0. (1) 66 OND FROM PANEL •MDP1•. CKT 3 SHORT CKT RTG.I.ym 14.0006 0 480VAC REVISED CKT DATE REVISED JOB NO OCT 2002 (VJB) CIRCUIT FRAMES & AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION a b e 1a 15A13P 112 JPO ALL) BAND SAW 1/4 300 300 300 BOILER ROOM 3b 15A 13P 612 (JET) DRILL PRESS '' 2 1 7 1 7 1 7 BOILER ROOM 5e 156 / 3P 112 (BALDOR) GRINDER 3/4 0 7 0 7 0 7 BOILER ROOM 7a 15A13P /12 (POWERMATIC) SANDER 1/2 15 15 15 BOILER ROOM 9b 15A/3P - SPARE - SPARE BOILER RM 11c 15A/ 3P 9b SPARE SPARE BOILERRM 13a 15A / 2P / EMPTY 66 OFFICE TRAILER - 5 0 5 0 - W EST OF BUILDING 15b 15A / 3P 612 INSTRUMENT AIR COMPRESSOR 1 5 0 5 0 5 0 COMPRESSOR RM 174 40A /3P - SPARE - 6 MEN LOCKER 19a 70A / 9P 68 ELEVATOR '15 19 6 19 6 19 6 ROOM 216 21b 15A /9P 112 (ZEKS) A05 -02 AIR DRYER 15.1/6 41 41 4.1 COMPRESSOR RM 23c / - EMPTY - 19• 90A 7 9P 66 CONE ROOM 214 25a / - EMPTY - 48.0 STEAM CLEAN 21b / 27b 20A / 1P EMPTY (1) RECEPTACLE 1.5 CHIEFS OFFICE 29e • ✓ VAV BOXES -2 1/10 . . . 2.5 2ND FL OFFICES 31a 112 P-2A 3/4 13.8'. BOILER RN 336 20A 1 17 112 (1) RECEP. 21 -61 -16 1/4 • ROOF 35e 30A / 1P 612 ... .•p. 1.5 BOILER RM 37a 206 / 1P 112 VAV-2 P26 1710. 3/4 18 _ .la.e.. MECH RM / BOILER 966 396 20A / 1P 112 (1) RECEPTACLES • 1.5 TOOL STORAGE 41e 20A /IP 612 • -__ 10 CORRIDOR. TOILET - •- 2a 15A/8P - SPARE UH-2. VAV-5 1/20.1/2 9.4, • 4b 15A / 3P - SPARE - f.i.' ' 8.8 6c 15A/3P • SPARE (3) RECEPTACLES 4.5 (la 15A / 3P • SPARE - SHOW ER LIGHTS 1 75 10b 156 / 3P 20A / 17 SPARE • _ �• .. -. - , 3 y . 124 156 / 3P 612 21 -EF -17 [BOILER 966) r 1 1.6 1.8 1 6 ROOF. COL B -7 14• 15A 1 3P - SPARE 1.6 1 6 1 8 ROOF. COL . 0-2 16b 15A / 3P - SPARE - SPARE 1.5 i8c 70A /3P - SPARE - SPARE 105 20a 60A13P 64 PANEL' P1• SUBFEED - 8a 1561 3P s BOILER RM 22b 15A/ 3P 612 (ZEKS)AD5 -01 AIR DRYER 1.5. 1/6 4 1 4 1 4 1 COMPRESSOR RM 24e / - EMPTY - _ 112 (2) RECEPTACLE 3' 26a / - EMPTY SPARE 112 4.5 .� 14a 20A 1 3P 412 #12 EF-3 [STEAM CLEANING[ 5 6 6 6 6 6 8 ROOF. COL' 9.4 16b 3081 3P - 275 SPARE ROOF, COL B2 346 20A / 1P 112 18e - 2 75 SPARE 96c 20A /IP f10 LIGHTS & RECP OUTISDE HV -13 20a / - 38a EMPTY (12 (1) RECEPTACLE 1.5 22b 60A 1 3P 18 412 VAP -1 42 9 42.9 42.9 PROPANE STATION 1561 17 112 YAV BOXES 3, -5 1/4.1/2 . . 8 6 W OMEN'S LOCKER 73.3 793 883 TOTAL AMPS REMOVE EXISTING MOTOR CIRCUIT. REUSE EXISTING BRANCH CURCUIT FOR REPLACEMENT FAN. A No. REVISION BY APP'D DATE ELE CTRICiL PWREL SCHEDULE PANEL PB BLDGMAINTENANCE TYPE WESTINGHOUSE WEHB -SE56625_IT.4 -2' SURFACE or FLUSH• SURFACE MAIN BKR. MLO RATING 225A, 400V DELTA, 3PH, 3W REF DWG NO(s) REVISION(s) AS BUILT (MFD) ENGINEER JS PELMAN (206-283-3713) BASE AB DATE LOCATION CORRIDOR, CO L. 6 4 FEEDERS (3) f2 /0, (1) 66 01413 FROM PANEL'MDP1•. CKT 4 SHORT CKT. RTG.Isym 14.0006 0 460VAC REVISED CKT. OATE REVISED JOB NO 28- M.r•07 OCT 2002 (VJB) CIRCUIT FRAMES 8 AMPS WIRE SIZE DESCRIPTION HP DESCRIPTION HP AMPERAGE LOCATION a b c 1a 15A/ SP - SPARE COMPRESSOR 36 20A / 1P 612 (2) RECEPTACLES 3b 156/ 3P - BOILER RM. ELEC RM SPARE 20A / 17 612 ENERGY MONITOR PANEL 54 15A/ 9P - 20A / 17 SPARE (3) RECEPTACLES 4.5 15T AID 7a 156/ 9P - SPARE SPARE BOILER RM 11e 15A/1P 9b 15A/3P SPARE BOILERRM 13a 15A /1P 612 6690-21 11e 15A/3P - MECH RM2ND FL SPARE 20A / 1P 112 (131) (8) RECEPTACLES 12 13a 20A / 3P - 20A /1P SPARE (4) RECEPTACLES 6 MEN LOCKER 15b 30A13P - (1) RECEPTACLE SPARE CONE ROOM 214 216 20A / 1 P 174 90A/3P - 3 SPARE CONE ROOM 214 294 20A / 1P 612 (1) RECEPTACLE 19• 90A 7 9P 66 CONE ROOM 214 PARTS WASHER 1/(20 48.0 48 0 48.0 STEAM CLEAN 21b / 27b 20A / 1P EMPTY (1) RECEPTACLE 1.5 CHIEFS OFFICE 29e • ✓ VAV BOXES -2 1/10 . . . 2.5 2ND FL OFFICES 31a 112 P-2A 3/4 13.8'. BOILER RN 336 20A 1 17 112 (1) RECEP. 21 -61 -16 1/4 • ROOF 35e 30A / 1P 612 ... .•p. 1.5 BOILER RM 37a 206 / 1P 112 VAV-2 P26 1710. 3/4 18 _ .la.e.. MECH RM / BOILER 966 396 20A / 1P 112 (1) RECEPTACLES • 1.5 TOOL STORAGE 41e 20A /IP 612 (3) RECEPTACLES (EWC) -__ 10 CORRIDOR. TOILET 2a 20A117 612 UH-2. VAV-5 1/20.1/2 9.4, • BOILER RM, AST FL OFF 46 20A/ 17 412 f.i.' ' 8.8 BOILER R66 64 T 612 (3) RECEPTACLES 4.5 BOILERRM 84 20A / 1P 112 (DL) SHOW ER LIGHTS 1 75 M & W LOCERS .�.r. 20A / 17 .. _ �• .. -. - , 3 y . .�.v. . .ter. `. _/ 612 HOT WATER CI RCPUM P. HW HEATER 2. 15A 7 3P 112 14a EF -29 [PAINT CLEANUP] 3/4 1.6 1 6 1 8 ROOF. COL . 0-2 4b 15613P 156/ IP 612 SPARE 1.5 2nd FL HALLWAY 184 6c 15# 1 3P - SPARE 105 2nd FL OMEN'S RR 2Da 206 / 17 412 112 8a 1561 3P - I ; SPARE 22b 20A / 17 24e 208 / iP f12 106 1SA / 3P - 3 SPARE 26a _ 112 (2) RECEPTACLE 3' 124 20A 1 3P - 28b SPARE 112 (3) RECEPTACLES 4.5 .� 14a 20A 1 3P 412 #12 EF-3 [STEAM CLEANING[ 5 6 6 6 6 6 8 ROOF. COL' 9.4 16b 3081 3P - 275 SPARE ROOF, COL B2 346 20A / 1P 112 18e 50A / 3P 2 75 SPARE 96c 20A /IP f10 LIGHTS & RECP OUTISDE HV -13 20a / - 38a EMPTY (12 (1) RECEPTACLE 1.5 22b 60A 1 3P 18 412 VAP -1 42 9 42.9 42.9 PROPANE STATION 1561 17 112 YAV BOXES 3, -5 1/4.1/2 . . 8 6 W OMEN'S LOCKER v i •a .-• t 0. A .Fnt1.. w • 991 991 991 TOTAL AMPS ELECTRICAL PANEL SCHEDULE PANEL P1 BLDGMAINTENANCE TYPE WESTINGHOUSE 9103'SE56625_IT SURFACE or FLUSH • SURFACE MAIN BKR 150AMPS RATING 150A, 225AN, 120Y/208V, 3PH, 4W REF DWG NO(s) REVISION(s) AS BUILT (MFD) ENGINEER JS PELMAN (206 - 2633713) BASE AB DATE 3 -3' LOCATION 8011ER ROOM FEEDERS (4)62/0. (1) t8 ONO FROM PAN EL 'PA'. CKT 20: VIA XFMR T1 45KVA SHORT CKT RTG.. Isym 10.000A 0 240VAC 2- Apr.D7 REVISED CKT. DATE REVISED JOB NO OCT 2002 (VJB) CIRCUIT FRAMES & AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION a 6 c 1a 20A/ IP 112 (3) RECEPTACLES 4.5 COMPRESSOR 36 20A / 1P 612 (2) RECEPTACLES 3 BOILER RM. ELEC RM 5e 20A / 17 612 ENERGY MONITOR PANEL 1.5 BOILER RM 7a 20A / 17 112 (3) RECEPTACLES 4.5 15T AID 9b 20A / 1 P 612 SPARE BOILER RM 11e 15A/1P 612 PP14 FUEL OIL TRANSFER PUMP 173 72 BOILERRM 13a 15A /1P 612 6690-21 2, MECH RM2ND FL 15b 20A / 1P 112 (131) (8) RECEPTACLES 12 MEN LOCKER. 2ND HALL 17c 20A /1P 112 (4) RECEPTACLES 6 MEN LOCKER 19a 20A / 1P 612 (1) RECEPTACLE 1.5 CONE ROOM 214 216 20A / 1 P 612 (2) RECEPTACLES 3 CONE ROOM 214 294 20A / 1P 612 (1) RECEPTACLE 1.5 CONE ROOM 214 25a 20A /1P 612 (1)RECEPTACLE 1.5 CONE ROOM 214 27b 20A / 1P 612 (1) RECEPTACLE 1.5 CHIEFS OFFICE 29e 15A/ 1P 612 VAV BOXES -2 1/10 2.5 2ND FL OFFICES 31a 206/1P 112 P-2A 3/4 13.8'. BOILER RN 336 20A 1 17 112 (1) RECEP. 21 -61 -16 1/4 7.3 ROOF 35e 30A / 1P 612 IRRIGATION CH TL 1.5 BOILER RM 37a 206 / 1P 112 VAV-2 P26 1710. 3/4 18 _ MECH RM / BOILER 966 396 20A / 1P 112 (1) RECEPTACLES 1.5 TOOL STORAGE 41e 20A /IP 612 (3) RECEPTACLES (EWC) -__ 10 CORRIDOR. TOILET 2a 20A117 612 UH-2. VAV-5 1/20.1/2 9.4, BOILER RM, AST FL OFF 46 20A/ 17 412 P.3A, P38 1/8.1/6 8.8 BOILER R66 64 20A /17 612 (3) RECEPTACLES 4.5 BOILERRM 84 20A / 1P 112 (DL) SHOW ER LIGHTS 1 75 M & W LOCERS 106 20A / 17 612 (2) RECEPTACLES 3 y . BAY 2 / 2nd Fl STORAGE 124 206 /1P 612 HOT WATER CI RCPUM P. HW HEATER 34 BOILER RM 14a 15A / 1P 812 FIRE SMOKE DAMPERS 1 5 16b 156/ IP 612 (1) RECEPTACLE (EW CI 1.5 2nd FL HALLWAY 184 206/ 17 612 (7) RECEPTACLES 105 2nd FL OMEN'S RR 2Da 206 / 17 412 112 (6) RECEPTACLES. LTS ON ROOF STAIRS (1) RECEPTACLE 10.6 " 1 5. I ; MECH RM. PARTS 215 2ND FL CONE RM 22b 20A / 17 24e 208 / iP f12 (2) RECEPTACLE ''' 3 2ND FL CONE 984 26a 20A / 17 112 (2) RECEPTACLE 3' 2ND FL CONE RM 28b 20A / IP 112 (3) RECEPTACLES 4.5 .� 2ND FL CONE/ OFFICE 30e 20A / 17 #12 VAV-4 1/3 - - 4 BOE OFFICE 32a 20A /IP 112 LIGHTS & RECP OUTISDE HV -11 275 ROOF, COL B2 346 20A / 1P 112 LIGHTS & RECP OUTISDE HV-12 2 75 ROOF, COL B-8 96c 20A /IP f10 LIGHTS & RECP OUTISDE HV -13 '. - 275 ROOF, COLS -13 38a 20A / 1P (12 (1) RECEPTACLE 1.5 CHASSIS. BAY 2 40b 15A /IP 412 VAV BOXES 3,d 1/4.1/3 72' LUNCHROOM, HENS 42c 1561 17 112 YAV BOXES 3, -5 1/4.1/2 . . 8 6 W OMEN'S LOCKER NE REPLACE 1 /2HP MOTOR WITH 3 /4HP MOTOR. INCREASE LOAD 76 3 57 6 68 9 TOTAL AMPS ADD 21 -EF -16 AND RECEPTACLE (880 VA). CHECKED: C.REYNOLDS RECOMMENDED: PROJECT K. MADDEN APPROVED: B. ISLER C 1815 N0: 432692/4.32721 SOW MUM CONTRACT 140: SCALE: NONE ONE INCH AT FULL SIZE I ) IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: ID219ES 6/13/OF D CRIPPEN C00130007 King County Department of Transportation RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER METRO TRANSIT DIVISION ATLANTIC BASE EXHAUST FAN REPLACEMENT PANEL SCHEDULES MAINT. BUILDING DATE MAY 2007 DRAw1NC 140: 1 E6.02 SHEET NO: OF 26 53 ELECTRICAL P►REL SCHEDULE PANEL P2 (I) BLDGMAINTENANCE TYPE WESTINGHOUSE WCA'SE56625 IT.3 -4' SURFACE or FLU SH• SURFACE MAIN BKR 250AMPS RATING 250A,400AN,120Y /208V, 3PH ,4W REF DWG. 810(4) REVISION(.) AS BUILT (MFD) ENGINEER JS PELMAN 1206-263-3713) BASE AB DATE LOCATION CORRI00 R. COI.. B 4 FEEDERS (41430014CM. (1) 42 GND FROM PANEL •M D P1•, CKT 10. VIA XFMR T2 SHORTCKT RTC Isym 10.00 DA 0 240VAC 2- Apr -07 REVISED CKT DATE REVISED JOB NO OCT 2002 (VJB) CIRCUIT FRAMES 8 AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION a b c 1a 20A / 1P 112 (3) RECEPTACLES 3 �1 • PARTS STORAGE, HALL 35 20A / I P 812 (3) RECEPT (FRIDGE. MICROWAVE) 112 15 y . PARTS OFFICE 5c 20A / 1P 812 RECEPT 8 LIGHT 20A 11P . 2.5 ELEVATOR PIT 7a 20A / IP 112 (DL) (8) RECEPT. JIB CRANE 1/2 18 20A /1P PARTS STORAGE 95 20A / 1P 812 LIGHTS ON FLOOR 9 II ., PAINT PREP 110 20A/ 1P 412 (1) RECEPTACLE _ 1 5 UNIT STORAGE 13a 20A / 1P 412 1 RECEPTACLE 1.5 •• J,� UNIT STORAGE 155 2DA/ 1P 112 (1) RECEPTACLE 2081 IP 16,,• • UNIT STORAGE 170 20A /1P 112 (3) RECEPTACLES 19n s 16 STEAM. BRAKE 19a 20A /1P 112 (3) RECEPTACLES 3 •�j _ STEAM. BRAKE 215 20A/ 1P 412 LIGHTING 125a•, 23c PAINT SHOP 23c 20A / 1P 412 (3) EP RECEPTACLES , 1 PAINT PREP, S WALL 25a 20A/ IP 112 ELEV LTS 8 (2) NEC 21 -EF-05 1140 26 .'• , ELEVATOR EQUIPMENT 275 20A / 1P 412 SUMP PUMP CONTROL 13 4.5 CHASSIS BAY 18. 17 29e 20A / 1P 412 MERCURY LIGHTS SPARE .•. PAINT ROOM . 31a ' 5' SPARE EINEMNIMIIIIMPlumumunt mwsimitimolimminimeminimaimoniamunmmmen 60A / 3P (3) 010 TIRE 8 W HEEL BALANCER 20A / 1P 5 . 4 . •• TIRE SHOP 65c 5 frilffifiRMIIIIIII Mille MN 20A / IP 5 (1)RECEPrACLE [DC POW ER SUPPLY) 67a 20A /1P 012 812 (2 ) EP RECEPTACLES J1) EP RECEPTACLE 3 15 • • . ,, PAINTING PAINTING 695 20A / IP 715 20A / 1P 012 (1) EP RECEPTACLE 39b • 1 5 2a 2081 1P~ 412 (3) RECEPT (MICROWAVE. FRIDGE) 15 812 PARTS PAINT CLEAN 4b 15A / IP 812 EF5 •1 1/4 15A/1P 6 • .. PARTS CLEANUP 6c 20A/ 1P 112 (1) RECEPT (4) EP RECEPT 208/1P 012 75 PAINT PREP. N WALL 8a 20A / 1 P 112 (2) RECEPTACLES 3 412 VAV BOX -1 1/10 PARTS STORAGE lOb 2DA / 1P 812 (DL) (2) RECEPT. (1) EP RECEPT 15A /IP 4 5 • TIRE SHOP. PAINTING 12c 208 / 1P 412 (3) RECEPTACLES 15A 1 IP 812 4 5 TIRE SHOP 14a 20A / 1P 11 2 (3) EP RECEPTACLES 4.5 112 •••, PAINT PREP, S WALL 16b 20A 1 1P 112 (2) RECEPTACLES 20A / 2P (2) 012 • FAREBOX, TIRE 18. 2081 IP 812 (DL) (4)RECEPT. SIEMENS EFCNTRLPNL (6) RECEPTACLES 9 STEAM STEAM GEN 20• 208 1 1P /12 (DL) (5) RECEPTACLES 7 5 (2) 412 (RED DEVIL) PAINT SHAKER 1/3 TIRE. STEAM. FAREBOX 225 20A 1 IP 812 (8) RECEPT. (1) PLUG STRIP - - SPARE OLY'S OFFICE 245 20A / 1P 812 (5) RECEPT. (2) PLUG STRIPS 20A'/ 1P 012 17 5 OLY . FAREBOX 26a 20A /IP 812 (3)RECEPTACLES 6 012 • FAREBOX 285 20A / 1P 112 (1) RECEPTACLE 20A / IP 812 •_, • FAREBOX. HALLWAY 305 20A /1P 112 _ �.` 012 (1) RECEPTACLE ' •L 20A/ 1P 15 OLY'S OFFICE 62a 20A / 1P 812 (1) QUAD RECEPTACLE 3' , Fimmeimmessieurialmewommalmosimisimmunimpoprnmetwffironswe INICRINIONIMINIONIIMPIPM1111111,111111111=1.11111111MININIMMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMUMI OLY'S OFFICE 64b AM= 6 ...- "WM. RIIXIMNIIIIMIIIIIM ALPIMIIIIIIIIIIIIMIIIMIll 680 520 555 TOTAL AMPS REPLACE EXISITNG FAN 21- EF -15. REUSE EXISTING BRANCH CURCUIT. No. REVISION BY APP'D DATE ELECTRIC PANEL P2(II) BLDGMAINTENANCE TYPE WESTINGHOUSE WEHB 'SE56625_IT.3 -4' SURFACE or FLUSH- SURFACE MAIN BKR MLO TAPPED TO P2111 RATING 400A 400AN, 120Y/208V, 3PH,4W REF. DWG NON) REVISION(.) AS BUILT (MFD) ENGINEER JS PELMAN (206 - 2633713) AL PAREL SCHEDULE BASE AB DATE LOCATION CORRIDOR. COI.. 8 -4 FEEDERS (4) /300MCM. (1) 12 GND FROM SUBPANEL OF PANEL •PA• SHORTCKT RTG. Isym 10.3008 0 240VAC REVISED CKT DATE REVISED JOB NO 2- Apr -07 OCT 2002 [VJB) CIRCUIT FRAMES 8 AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION • b e 31a 20A / 1P 812 (3) RECEPTACLES 4 5 �1 • STORES 201 33b 20A / 1P 812 DL (0) RECEPTACLES. OLY'S FRIDGE 112 6 - STORES 201. OLY 35c 20A /1P 812 DL (2) RECEPTACLES 20A 11P . 3 STORES 201 37a 20A/ 1P 112 (2) RECEPTACLES 3 20A /1P . ROOF ENTRY 395 20A / 1P 112 EF -11. F13 1/4 1/3 9 12 6 ., ROOF. COL. 5-6 415 20A / 1P 812 EF -12. F14 1/4.1/30 _ 7.5 ROOF. COL C -7.8 -5 43a 20A/ 1P 112 (I) RECEPTACLE 1.5 •• J,� PROPANE STORAGE 455 20A / 2P (2)010 PUMP PI ' 1 2081 IP 16,,• • PROPANE STORAGE 470 19n s 16 SPARE 49a 20A/ 1 P 110 (2) EP RECEPTACLES 3 •�j _ PAINTING 515 20A /1P 012 MICROWAVE RECEPTACLE 125a•, 23c LUNCHROOM 535 20A/ 1P 112 MICROWAVE RECEPTACLE , 12.3 LUNCH ROOM 55a 26 .'• , 57b 30A�/ 3P (3) 810 BATTERY CHARGER PANEL 13 4.5 TIRE SHOP 59c 29c 20A/ IP SPARE .•. - 61a 31a 158/ 1P 5' SPARE 635 60A / 3P (3) 010 TIRE 8 W HEEL BALANCER 20A / 1P 5 . 4 . •• TIRE SHOP 65c 5 ELEC SHOP 355 20A / IP 5 (1)RECEPrACLE [DC POW ER SUPPLY) 67a 20A /1P 012 812 (2 ) EP RECEPTACLES J1) EP RECEPTACLE 3 15 • • . ,, PAINTING PAINTING 695 20A / IP 715 20A / 1P 012 (1) EP RECEPTACLE 39b , 1 5 PAINTING - 32a 20A /1P 812 (1) EXTERIOR RECEPTACLE 15 - :• OUTSIDE PAINT SHOP 345 15A/1P 812 VAV BOX-6 3/4 18, -- PARTS STORAGE 36, 208/1P 012 SUMP PUMP PNL PP5 -01 02 15 1 TIRE SHOP 3Ba 15A / 1 P 412 VAV BOX -1 1/10 25 441. 17.5 FAREBOX REPAIR 405 15A /IP 112 RECEPTACLE OUTSIDE HV -1, HVZ (3) RECEPTACLES. (2) PLUG STRIPS 55 ROOF. COL. 9-2. AZ 42e 15A 1 IP 812 RECEPTACLE OUTSIDE HV-4 812 (3) RECEPTACLES 8 FAREBOX CCTV 2.8 ROOF. COL B3 44a 15A/1P 112 RECEPTACLES 3• �4, -^ 45b 20A / 2P (2) 012 (FRIEDRICK) AC 12c . FAREBOX REPAIR 480 (6) RECEPTACLES 4 165 5Da 20A / 2P (2) 412 (RED DEVIL) PAINT SHAKER 1/3 3.1 " �,; •t PAINT PREP 525 20A/ 1P - SPARE 3 1. 540 20A'/ 1P 012 RECEPTACLE OUTSIDE HV6 HV7 UH -1 UNIT HEATER a I 5 5 ROOF. COL B -5 56a 20A / IP 012 RECEPTACLE OUTSIDE NV -3 2.8 - ..• • • ROOF. COL B-2 585 20A / IP 812 EF -21 1/20 15A/ 1P 2 •• . 3 ROOF. COL B-3 _ 20A / 1P 012 (1) RECEPTACLE ' •L 20A/ 1P 15 OLY'S OFFICE 62a 20A / 1P 812 (1) QUAD RECEPTACLE 3' , 20A /1P OLY'S OFFICE 64b 6 ...- 5 . _ •_ 20A/ 1P 66e 20A / 3P (3) 412 TIRE CHANGER • - . 5 TIRE SHOP 6Ba , SPARE 5 J^ 705 30A / 2P (2) 110 HOT WATER HEATER 1 6 s',7., . JANITOR'S CLOSET 72c , �/ 1/2. 6 86 9( 1104 841 TOTAL AMPS PANEL P1 BLDGMAINTENANCE TYPE SO D NOOD 'NOOD 02' SURFACE or FLUSH • FLUSH MAIN BKR 125AMPS RATING 225A, 120Y/240A, 3PH, 4W REF DWG NO(.) REVISION(.) AS BUILT (MFD) ENGINEER JS PELMAN (206 - 263-3713) ELECTRICAL PAREL SCHEDULE BASE AB DATE LOCATION ELECTRON ICS HOP FEEDERS (3) 41 /0. (1) 44 N. (1/15 GND FROM PANEL • PH •, CKT 1, VIA 45 KVA XFMR T7 SHORT CKT RTG , Isym 2- Apr -07 REVISED CKT. DATE REVISED JOB NO OCT 2002 (VJB) CIRCUIT FRAMES 8 AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION a b c la 20A / 1P 812 [3) PLUG STRIPS 15 ELEC SHOP 3b 20A / 1P 112 (2) PLUG STRIPS - 15 ELEC SHOP 5c 20A 11P 412 812 {2) PLUG STRIPS [4) RECEPTACLES, DISPOSAL HOT H2O ID _ 10 , ELEC SHOP LUNCHROOM 7a 20A /1P 95 20A/ 1P 112 {6) RECEPTACLES [COMPUTER) 9 _ ELEC SHOP, OFFICES 110 20A / 1P 412 812 (3) RECEPTACLES RECEPTACLES OVER ELEC CHIEF OFF _ 4 5 OFFICES ELEC SHOP 13a 2081 1P 155 20A /IP 412 (1) PLUG STRIP - 5 ELFC SHOP 17c 2081 IP 112 SPARE TO JBOX IN ELEC SHOP 19n 20Al2P - SPARE 215 - ---,. 23c 15A 12P - SPARE , 25a r/ ... ..__ 27b 20A 1P 812 (3) RECEPTACLES 4.5 . HALL. ELEC SHOP 29c 20A/ IP SPARE .•. - 31a 158/ 1P - SPARE _ 33b 20A / 1P 812 (2) RECEPTACLES (DC POW ER SUPPLY] 5 ELEC SHOP 355 20A / IP 112 (1)RECEPrACLE [DC POW ER SUPPLY) J� 5 ELEC SHOP 37a 20A / 1P 812 (2) RECEPTACLES 3 - BRAKE SHOP 39b 20A/ 1P - SPARE ' 41c 20A /1P - SPARE ._ ..,_ 2n 20A /1P 412 (3) PLUG STRIPS 15 _ ELEC SHOP 4b 20A / 1P 812 (3)RECEPTACL ES (2) PLUG ST RI PS , 17.5 •• ELEC SHOP 6c 20A / 1P 112 (3) RECEPTACLES. (2) PLUG STRIPS 14 5 ELEC SHOP 8n 20A /1P 812 (3) RECEPTACLES 8 FAREBOX CCTV 9 _ . _ _ OFFICES 105 20A/ 1P 112 612 (1)RECEPTACLE (1) RECEPTACLE [DC POW ER SUPPLY( 15 _ 5 OFFICES ELEC SHOP 12c 20A / 1P 14a 20A/ 1P 612 (6) RECEPTACLES 9 LUNCHROOM 165 20A/ 1P - SPARE , 18c 20A/ 1P - SPARE 20a 20A / 1P 412 UH -1 UNIT HEATER 1/8 4 .+ • PUMP RM 22b 158/ 10 112 (11 RECEPTACLE , ,_ 15 - TIRE SHOP 245 15A/ 1P - SPARE _ 28a 20A/ 1P - SPARE 285 20A /1P 112 (4) RECEPTACLES 6 CHASSIS. BAY 12, 13. 14 30c 20A/ 1P 112 EF5 -02 [ELECTRONICS SHOP] 114 , 7 5 ROOF COL 8 -7 32a 50A /2P • SPARE 345 38c �/ 1/2. 3 4 38• 508 3P (3)48 HP5 •1 34 ROOF 001. A8 405 , 3 4 -_ 420 208/11 - SPARE REMOVE EXISTING BRANCH CIRCUIT. INSTALL RECEPTACLE CIRC DESIGNED: L MCFARLAND - LE 68.4 634 499 TOTAL AMPS REPLACE EXISITNG EXHAUST FAN 21 -EF5-02 AND ADD RECEPTACLE. REUSE EXISTING BRANCH CIRCUIT. RECEIVED CITY OF TUK\M A MAR 2 4 2008 PERMIT CENTER CHECKED: (1, C. REYNOLDS v' RECOMMENDED: K. MADDEN L'Yi APPROVED: / I B. ISLER (// � ®IS NO: 432692/432721 fORIL BMW: CONTRACT NO: ONE INCH AT FULL SIZE I 1 1 IF NOT ONE INCH. SCALE ACCORDINGLY SITE LOCATION NO: METRO TRANSIT DIVISION ATLANTIC BASE EXHAUST FAN REPLACEMENT DATE: MAY 2007 IOVDHEs 8 /13 /08 D CRIPPEN C00130007 King County Department of Transportation PANEL SCHEDULES MAINT. BUILDING DRAWING NO: 1 E6.03 SHEET NO: OF 27 53 GENERATOR INFORMATION SCHEDULE BLDG FUEL/WASH MANUFACTURER CUMMINS (DGFA- 5558477) SIZE I SOKW STANDBY 187.5 KVA TRANSFER SWITCH AUTOMATIC SWITCH RATING 226 Akr BASE AB DATE LOCATION ELECTRICAL ROOM FUEL TYPE DIESEL 2 -Apr -0 / MAX LOAD (AMPS) . DLstribution Panel Schedule PANEL EB BLDGMAINTENANCE TYPE WESTINGHOUSE WEHB (SE568251T4 -9) SURFACE or FLUSH' SURFACE MAIN BKR MLO RATING 225A. 480Y/ 277V. 3 PH. 4W REF DWG NO(s) REVISION(s) ENG'N EER As Bug (M ED) JS Pelman (206 -263 -3713) BASE AB DATE 2- Apr -0/ LOCATION ELECTRICAL ROOM FEEDERS (4) 54/0 (1) 560 FROM GEN /MDP VIA ATS SHORT CKT RTG Isym 14000AIC ® 480V REVISED CKT DATE REVISED JOB NO JUL D2 (JSP) CIRCUIT FRAMES 6 AMPS FRAMES & AMPS WIRE SIZE DESCRIPTION LOCATION HP AMPERAGE LOCATION a b 0 ' 30A/3P - SPARE 3b 204/ 1P - SPARE .. 3 I5A/3P 512 - 7a 5 512 15A/3P - SPARE 95 15A/ 2P (2)512 7 70A/3P 56 - - • i _S. , 9 13a 80A/3P 54 PANEL E2 VIA 46KVAXFMR 234 234 294 Ft FCT ROOM 11 - 205210 - SPARE 17c I • 17' . 13 205210 - SPARE 1112 ;3) RECEPTACL FS • —•••' TA, 1ST FLOOR 16 20A/ 1P / EMPTY t, _ •. 2041 1P 512 17 / - EMPTY 26a 20A / 1P g,+. '•� ••-• 19 / - EMPTY SPARE 290 21 / - EMPTY 'h .::a,..,• ,. -c 512 23 • .; / - EMPTY I 512 . .,,, 25 35c / - EMPTY _ ,W •, .:` 1 27 1 - EMPTY 395 '•' ' 41c 15A1 1P 512 UPS (LINE 1.2.3) < - 4 ELECTRICAL POOM • r • F "- ‘ ' •. y ... 1 �'a I,'` "" . 20Al2P �' a,. I • . � _ 4!IF�IT.17e6 _ J?._ 6c 1 . -a ti.>`s wrA..Y.`_ f.., .a r. e.. • - ., >': I.a[ i, : ,,eL�s+7+•e�_�_•rc , ... C w..,. •• .,.,.moo TaI' 4• . ,._ .. r 16A11P v 'lr.. ._ ... .. •.. -. +G, w.Y1,[ -A� 2 I652 3P - SPARE 16A/ 2P (2)512 4 12c 165230 512 ,_ . ' .. _ - ROOF 6 15N3P SPARE • — 16b 204/ 3P (3)512 8 60N 3P 56 PANEL "EL" SUBFEED 180 137 118 194 ELECT ROOM 10 40523P SPARE 204/ 1P 112 RECP® TELEPHONE BOARD 12 22b 60523P 51/0 PANEL ED-OPERATIONS RECP® PA/ INTERCOM SYSTEM ..- 222 308 180 OPERATIONS BLDG 14 / - EMPTY 26a •.k` 16 / - EMPTY 28b • `,}, {1$ .'.1 • , 18 / - EMPTY 154/ 'P 512 �, ... •' 20 32a 1 EMPTY SPARE w y ,�•i1� 34b 22 / - EMPTY ' _• 36c ,.,...5 24 . - / - EMPTY 38a «xe . «1 .a ' _.el - - - ,, . 40b 2041 2P SPARE ... 42c .. ;.t .,. • - », f y: .._s. -o -' •--'- •`.- .. to '. 5 c... . ... , • ' • .. _A _ , 96 91 81 TOTAL AMPS REMOVE BRANCH CIRCUIT ELECTRICAL PANEL SCHEDULE PANEL E2 BLDG FUEL /WASH TYPE WESTINGHOUSE B1OB (SE56625 IT3 21 SURFACE or FLUSH • SURFACE MAIN BKR 160 AMPS RATING 150A 225AN. 208Y/120V. 3P1/, 4W REF DWG 520(51 REVISION(s) ENGINEER AS BUILT (MFD) JS PE L14 AN (206 -263 -3713) BASE A8 DATE LOCATION ELECTRICAL ROOM FEEDERS (4) 2/0. (1) II DN. (1) 560 FROM VIA 54ORT CKT 91.3 . Isym 10000AIC ® 240 REV'SED CKT DAT F REVISED ,0B NO 2 -Apr -0 / XFMR TE2 APR 4. 2003 (JSP) CIRCUIT FRAMES 6 AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOCATION a b c 1a 2041 IP 512(DL) .. ,_._ „ LANEI 3b 204/ 1P - SPARE .. ' 6c 20A/ IP 512(DL) 7a 20A/ 1P 512 _ 95 15A/ 2P (2)512 • • ,_ 1 1 0 a ---A., 13a 1 16b 20A/ 3P (3)512 - - 17c I 17' . 19a 2041 1P 1112 ;3) RECEPTACL FS 4 6 1ST FLOOR 21b 20A/ 1P 612 t, _ 23c 2041 1P 512 26a 20A / 1P SPARE .. 27b 20A/ 1P SPARE 290 ISA! IP SPARE s , 31a 204/ IP 512 '- • .; e 33b I 512 .,,, 35c 2DA13P 012 • -. _ ,W 37a 1 • _,• . y _ 395 20A/ 1P 512 41c 15A1 1P 512 UPS (LINE 1.2.3) < - 4 ELECTRICAL POOM 2a 204/ 1P 5.12.,, 1 ( •.. • ... 4b 20Al2P (2)512 -.._ . - � _ _ 6c 1 �1 8a 16A11P 512 105 16A/ 2P (2)512 12c I .. _ - 14a 1 • — 16b 204/ 3P (3)512 180 1 20a 204/ 1P 112 RECP® TELEPHONE BOARD MEZZANINE 22b 20A /1P 112 RECP® PA/ INTERCOM SYSTEM ..- MEZZANINE 24c 15A / 1P SPARE 26a 20A/ 1P SPARE 28b 16A/ 1P SPARE 30c 154/ 'P 512 32a 20A1 IP - SPARE 34b 3041 2P SPARE , „_- 36c I . - 38a 204/ I P 512 - - - ,, . 40b 2041 2P SPARE 42c 1 . , . ` REMOVE BRANCH CIRCUIT TOTAL AMPS REVIEWEP�,pNCE CODE � p - NEC APR - 3 2008 Of Tukwila RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER A No. REVISION BY APP'D DATE I OCHRES 6/13/ OF DESIGNED: L MCFARLAND °9"w'r ,�� .r ele. - LE PROJECT MANAGER; K. MADDEN / //' • B. ISLER '✓ SCALE: NON E C. REYNOLDS RECOMMENDED: D. CRIPPEN 1915 NO: 432692/432721 +owl REGLOTT: ONE INCH AT FULL SIZE I 1' I IF NOT ONE INCH, SCALE ACCORDINGLY CONTRACT N0: CO0130007 SITE LOTION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT PANEL SCHEDULES FUEL WASH BUILDING DATE. MAY 2007 DRAWING NO: 1 E6.04 SHEET NO OF 28 53 ELECTRICAL PAREL SCHEDULE PANEL PF BLDG FUEL /WASH TYPE WESTINGHOUSE WEHB (0E56625 IT 4 -5) SURFACE Pr FLUSH' SURFACE MAIN BKR MLO RATING 100 A, 480V 3PH, 3W REF DW3 NO(') REVISION;') ENGINEER AS BUILT (MFD) JS PELMAN ;206- 263 -3/13) BASE AB DATE LOCATION ELECTRICAL 500 M FEEDERS (3) 16, (1) 200 FROM PANEL MOPE, CKT 67 SHORT CKT RTG lore 14.000 AIL 14 400V 2- Apr -02 REVISED CKT DATE REVISED JOB NO APR 4, 2003 (JSP) CIRCUIT FRAMES 6 AMPS WIRE SIZE DESCRIPTION HP AMPERAGE : OCATION a h c b 15A/ 3P 25 1 - SPACE 1 (3)/12 - - 11.1111.11111111.= SPACE - - 29 / - SPACE SA / 3P 1• 206/ 1P 812 DUPL. RECEPT (OLY'S DOORBELL) 3 MEZZANINE 3b - 1 12 (2) RECEPTACLES e . LANE 1 5, 20A /IP 112 - (1) RECEPTACLE SPARE 12.6 40A /3P - 206/ 1P 9b 5 SPARE 11, 606/ 3P (3) /6 PANEL'P5A SUBFEED MEN ) LANE 1 (WEST) 13a 156 206 / 3P EMPTY 111111 17c 19a / EMPTY 21b 20A /2P 1112 / EMPTY WOMEN'S TOILET 23e I 9 / - EMPTY 134 � / EMPTY . • 50A/ 3P (3)24 MAIN BREAKER 6 i 15A/ 3 P 2• 20A /1P Q (1)RECEPTACLE 2 ) (3)112 - 40 20A /1P 812 75 _ MEZZANINE 6c 20A / 1P 212 (DL) (3) RECEPTACLES 6 CEN BATT CHCER • • '' 25A / ]P ELECTRICAL ROOM 8a 20A / 1P 212 "1 • -- - 4 ( (3) 16 PANEL .1.5. SUBFE ITIL'Ill 20611P 212 BENCH RECEPTACLE 1• 3 r MEZZANINE 12c 40A/ 3P 212 TIME CLOCK 6 1 PARF _ 14• 2061 IP 812 IRRIGATION CONTROL PANEL .. ELECTRICAL ROOM 16b /111 112 - 8 20A/3P 7/i7 7 -EF -12 EXHAUST FAN 1.5 ?_- 204 206/1P 212 - - -_ 15 _ - FUEL ISLAND EMPTY 111111 - SPACE ., • ..- •22b u EMPTY / , [ EMPTY 3 ? . '4 31 2 31 2 31 2 TOTAL AMPS REPLACE EXISTING FAN. ADD MOTOR BRANCH CIRCUIT (2830VA). ELECTRI CAL PANEL P1 BLDG FUEL/ WASH TYPE SURFACE orFLUSH• SURFACE MAIN BKR. 180A RATING 226 A, 208/ 120V. 9PH. 4W R. DWG. NO(s) REVISION(s) ENGINEER PANEL SCHEDULE BASE AB DATE 2 -Apr -07 LOCATION ELECTRICAL ROOM FEEDERS (9) 44, (1) Y4N, (1) 48C HIGH MDP1 CKT P 11 SHORT OCR. RTG-, Isyrn 10,000 REVISED OCT, DATE REMSEED JOB NO- FRP&ES OROU(T & AMPS WIRE SIZE DESCRIPTION HP AM ERAC,E la 3b 5c 7a 20A/ 1P 20A/ IP 20A/ 1P 20A/ IP 12 7 17- EFZGV1 12 7 4F3,7- 4,612 12 7- 5.7- FB,GV9 (2)1/4 12 RECEPTACLE 2)1/4 m 1/ 4 21114 9b 20A/ 1P 12 REC>FT'ACLES I I c 20A 1P 12 RECEPTACLES SPARE SPARE 'SPACE SPACE SPPO SPACE SPACE SPACE SPACE LOCATION III !!' MRSOINIPININAll r. ' WIIP. 9r7 1101111111 ESWIIIMMIPMM1.1 MAIM?. 20A/ 1P 20A/ 1P 20A/ 1P 20A/ 1P 20A/ 1P 20A/ 112 20A/ 1P MA 1P 18c 20a 22b 24c 28 28 30 12 12 12 7- 7,7$8.GV4 (21114 7-O,7-B-10.7-.11 1/6,1/40,1/40 RECEPTACLE SPARE SPARE SPARE SPARE SPARE SPACE SPACE SPACE SPACE SPACE SPACE SPACE OINIFIMMIll , _ =MA MffialM. .. •- MEMIN 25.5 16.5 TOTAL AMPS NEW PANEL "P 1 " (IN F/W BLDG.) SCALE: NTS ELECTRICAL PANEL SCHEDULE PANEL P5 BLDG FUEL /WASH TYPE WESTINGHOUSE B10B (SE58825 IT.3 -7) SURFACE or FLUSH' SURFACE MAIN SKR SD AMPS RATING 100 A. 10GAN, 230Y/ 120 V. 3PH, 4W REF DWG NOW REVISION(') ENGINEER AS BUILT (MFD) J5 PELMAN (206 - 263-371(( BASE AB DATE 2- Apr -07 LOCATION ELECTRICAL ROOT! FEEDERS (4) t4. (1) 08G FROM ABCB -FW -PF ( /4) VIA 15KVA XFMR T5 SHORT CKT RTO. Iay.. 10,000AIC ® 240V REVISED CKT DATE REVISED APR 4.2003 (JSP) JOB NO CIRCUIT FRAMES 6 AMPS WIRE SIZE DESCRIPTION HP AMPERAGE LOG TION • b c 25 1 - SPACE J 27 / - SPACE 29 / - SPACE 1• 206/ 1P 812 DUPL. RECEPT (OLY'S DOORBELL) 3 MEZZANINE 3b 206 / 1P 1 12 (2) RECEPTACLES 3 LANE 1 5, 20A /IP 112 - (1) RECEPTACLE SPARE 12.6 COMPRESSOR RM 7a 206/ 1P 9b MEM 11, 606/ 3P (3) /6 PANEL'P5A SUBFEED MEN 111111111 LANE 1 (WEST) 13a 156 206 / 3P 17c 19a 21b 20A /2P 1112 WOMEN'S TOILET 23e I 112 134 . 50A/ 3P (3)24 MAIN BREAKER 6 i 2• 20A /1P /12 (1)RECEPTACLE 15 MEZZANINE 40 20A /1P 812 (5) RECEPTACLES 75 _ MEZZANINE 6c 20A / 1P 212 (DL) (3) RECEPTACLES 6 CEN BATT CHCER • • '' ELECTRICAL ROOM 8a 20A / 1P 212 "1 • -- - • • .j ELECTRICAL ROOM lOb 20611P 212 BENCH RECEPTACLE 1• 3 r MEZZANINE 12c 20A/ 1P 212 TIME CLOCK ELECTRICAL ROOM _ 14• 2061 IP 812 IRRIGATION CONTROL PANEL .. ELECTRICAL ROOM 16b 156 / 1P 112 - _ 18c 20A /1P 212 1.5 FUEL ISLAND 204 206/1P 212 - - -_ 15 _ - FUEL ISLAND / - SPACE ., • ..- •22b u 24c / - SPACE 3 ? . 10 27.9 34 TOTAL AMPS REPLACE EXISTING FAN CONTROL PANEL. REUSE EXISITNG CIRCUIT. RECEIVED CITY OF TUKWI'LA MAR 2 4 `Z0U8 PERMIT CENTER No. REVISION BY APP'D DATE � DOMES 6/13/0 DESIGNED: L McFARLAND r‘r•' D. LE PROJECT K. MADDEN APPROVED: B. ISLER SCALE: N/A CHECKED: L McFARLAND I&5 NO 432692/432721 antic AEW,FST: - ONE INCH AT FULL SIZE I 1• I IF NOT ONE INCH, SCALE ACCORDINGLY RECOMMENDED: D. CRIPPEN CONTRACT NO: C00130007 SITE LOCATION 110: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT PANEL SCHEDULES FUEL WASH BUILDING DATE: MAY 2007 DRAWING NO: 1 E6.05 SHEET NO: OF 29 53 L1 L2 L3 1 1 1 480 -24V 150VA NOTES 21 -EF -2A 480V, EXHAUST FAN CONTROL CIRCUIT SCHEMATIC SCALE: NTS RUN SIGNAL FOR 7- EF -14, USE CONTACT IN EXHAUST FAN CONTROL PANEL INSTEAD OF THERMOSTAT. CONTACT "C" LOCATED IN EXHAUST FAN CONTROL PANEL. L1 L2 L3 4B0 -120V ❑L OL I I I I I I I I I II I I E ADJ. SET AT 85'F ADJ. SET AT 85'F 480V, 7- EF -14. 7 -EF -14 AND 21- EF- 17EXHAUST FAN CONTROL SCHEMATIC SCALE: NTS 0 0 F -10, 7- EF -11, 21 -EF -15 AND 7 -EF -1 THROUGH 7 -EF -8 120V FUEL LANE EXHAUST FAN CONTROL SCHEMATIC SCALE: NTS 21 -EF -16 120V EXHAUST FAN CONTROL SCHEMATIC SCALE: NTS RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. 1 REVISION BY APP'D' DATE I COMES A/13/0g DESIGNED: L McFARLAND CHECKED: C. REYNOLDS0 RECOMMENDEo- D CRIPPEN 126 PROJECT MANAGER: K. MADDEN WINCHED: B. SLER IBIS NO: 432692/432721 Romc R EOUM — CONiRPCT NO: NONE C0013C07 ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATIGN NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT EXHAUST FAN CONTROL AND THERMOSTAT CONTROL SCHEMATIC DATE MAY 2007 DRAWING NO: 1 E6.06 SHEET NO: OF 30 53 m0 LASHING HT SET BOLTS IN SEALANT NEOPRENE PAD /- SPECIFIED METAL COVER WITH RECEIVER FOR COUNTERFLASHING HIGH - DOMED, CAPPED, GASKETED FASTENERS (APPROX 18" OC) REMOVABLE SHEET METAL COUNTERFLASHING FASTENERS APPROX 8" OC 2" EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT (NOT SHOWN FOR CLARITY) NEW CANT SPECIFIED MEMBRANE BASE FLASHING (8" MIN HEIGHT) 4° 4" icor 1" (TYP) LC— EXISTING COVERBOARD EXISTING TAPERED THERMAL ' NSULATION -- EXISTING CONCRETE ROOF DECK EQUIPMENT SUPPORT CURB DETAIL SCALE: NONE VARIES 0 FIELD !VERIFY EXISTING OPENING DIMENSIONS 0 L SPECIFIED ROOF MEMBRANE REPLACE EXISTING BLOCKING IF DAMAGED. SEE DEMOLITION NOTES /G1.01 & CONSTRUCTION NOTE 1/A5.01 3" ALL AROUND 4 ROOF CLOSURE PLATE DETAIL SCALE: NONE 2 M1.03 Y4" STEEL PLATE Y4 "DIA X 1X" MIN EMBEDMENT EXPANSION ANCHORS 4" MIN 4" MIN FLAT BAR TERMINATION BAR FASTENERS APPROX 8" OC FASTENERS APPROX 18" OC r REMOVABLE SHEET METAL COUNTERFLASHING EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT (NOT SHOWN FOR CLARITY) � SPECIFIED BASE FLASHING (8" MIN HEIGHT) /A. h-- SPECIFIED ROOF MEMBRANE EXISTING COVERBOARD — EXISTING THERMAL INSULATION i— - EXIS TINE CONCRETE ROOF DECK REPLACE EXISTING BLOCKING IF DAMAGED. SEE DEMOLITION NOTES /G1.01 & CONSTRUCTION NOTE 1 /A5.01 4" MIN 4" MIN NEW CANT RAISED CURB FOR LARGE HVAC UNIT DETAIL SCALE: NONE VARIES c ;1J • s ray V 44 �•�Tee∎re a ilr� . e..OVV ■∎r Pe a *Siv_v i4 o••• •• ••L•_4:vr : _..VIA r9•_e' :P:.T.bAU_di • • • X ▪ x x EXISTING OPENING ROOF CLOSURE DETAIL %41 SCALE: NONE - REVIEWED FOR CODE COMPLIANCE E NFPA - 3 2008 City Of Tukwila �►. D I!N REMOVE FAN CURB INSTALL NEW ROOFING MEMBRANE TO MATCH EXISTING, EXTEND OVERLAP AS SHOWN INSTALL NEW INSULATION & COVERBOARD TO MATCH EXISTING EXISTING ? �Ck�r.`'• :� E_�K L EXISTING - TT EXISTING COVERBOARD `HERMAL INSULATION CONCRETE ROOF DECK RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: Y FARJO PROJECT MANAGER: K MADDDEN AS NOTED D RAWN: B FARISS - BATEMAN CHECKED: J DAVICi APPROVED: B ISLER J / j IBIS NO: 432692 & 432721 sax xmJESt ONE INCH AT FULL SIZE T• IF NOT ONE INCH, SCALE ACCORDINGLY RE'COM D CRIPPEN fl,' �• CONTRACT NO: COO130C07 SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE OPERATIONS (Sc MAINTENANCE BUILDING CONSTRUCTION DETAILS DATE MAY 2007 DRAWING NO: 2 A5.01 SHEET NO: OF 31 53 EXISTING 36" x 10' DOUBLE TEE BEAM BELOW (TYP) SLOE 22 GAGE STAINLESS STEEL SHEET FLASHING TO ORA N. MIN SOPE = 4" PER 1 F. PROVIDE BLOCKING AND CANT AS REQUIRED O SOUTH BASE MAINTENANCE BUILDING PARTIAL ROOF PLAN n SCALE: 1/4" = 1' -0" 2 M1.03 WALL AT SECOND FLOOR LEVEL L J O 0 O NEW ROOF OPENING ABOVE EXISTING 1ST : LODR CVO WALL 2 S5.01 s ' A/2 S5.01 ENLARGEMENT OF EXISTING OPENING IN MASONRY WALL DETAIL SCALE: 1" = 1' -0" — 0_ UI Al 1111E1 I�I�I 2 S5.01 ENLARGE DUCT OPENING IN CMU WALL ABOVE DOOR AT 1ST FLOOR COMPRESSOR ROOM. REINFORCE OPENING PER 1/2 S5.01 �r I I L -- - J NEW OPENING ABOVE FOR EF -109 COMPRESSOR ROOM ENLARGE EXISTING WALL OPENING TANK A,.COVE 0' 0 0 L_ 0 (N 0 W F- J co Q LJ RFSTROOM EQUIPMENT ROOM CONFERENCE ROOM EXISTING WALL BELOW -- EX!ST NG OPENING C9_) SOUTH BASE MAINTENANCE BUILDING PARTIAL FIRST FLOOR PLAN SCALE: 1/4" = 1' -0" 2 M1.03 m M NEW 5" EXISTING 2ND FLOOR WAIL BELOW NEW CURBING SHALL EXTEND OVER WEB OF EXISTING TEE BEAMS co . W0 0 J z nl 1- vi NEW PREFABRICATED METAL CURB. CONNECT TO EXISTING CONCRETE TOPPING SLAB W/ MIN OF (8) ) "0x2Y4" MIN EMBEDMENT STAINLESS STEEL EXPANSION ANCHORS ROOF CURB PLAN AT ENLARGED 0 m W F CJ CD 0 1-D] CO CO OPENING DETAIL SCALE: 1" = 1' -0" REPLACE CURB AT EXISTING WATER HEATER EXHAUST STACK A5.02 SIMILAR AT CLAMPS AND STORM COLLAR FLASHING EX,SIINU 2ND FLOOR WALL BELOW EXISTING WATER HEA'E.R STACK ENLARGEMENT OF EXISTING OPENING IN ROOF DECK DETAIL SCALE: 1" = 1' -0" — DEMOLITION NOTESz 1. REMOVE EXISTING ROOFING MATERIAL TO THE EXTENT REQUIRED, CONFORMING TO THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. 2. SAWCUT AND REMOVE EXISTING CONCRETE DECK (3" TEE BEAM FLANGE + 3" TOPPING SLAB) TO ENLARGE EXISTING OPENING FOR NEW DUCT. 53 E o 2 2 RECEIVED OF TUKWILA KEY PLAN SCALE: 1/64" = 1' -0" MAR 2 4 NA PERMIT CENTER No. I REVISION BY APP'D DATE PROJECT IIHUCER [mots 9/n/ G C00130007 SCALE AS NOTED ONE INCH AT FULL SIZE I ' 1 IF NOT ONE INCH. SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING PARTIAL PLAN 8c DETAILS DATE: MAY 2007 DRAWING NO: 2 S4.01 SHEET NO: OF 32 53 \ / NEW OPENING / 1 5.01 1 co . W0 0 J z nl 1- vi NEW PREFABRICATED METAL CURB. CONNECT TO EXISTING CONCRETE TOPPING SLAB W/ MIN OF (8) ) "0x2Y4" MIN EMBEDMENT STAINLESS STEEL EXPANSION ANCHORS ROOF CURB PLAN AT ENLARGED 0 m W F CJ CD 0 1-D] CO CO OPENING DETAIL SCALE: 1" = 1' -0" REPLACE CURB AT EXISTING WATER HEATER EXHAUST STACK A5.02 SIMILAR AT CLAMPS AND STORM COLLAR FLASHING EX,SIINU 2ND FLOOR WALL BELOW EXISTING WATER HEA'E.R STACK ENLARGEMENT OF EXISTING OPENING IN ROOF DECK DETAIL SCALE: 1" = 1' -0" — DEMOLITION NOTESz 1. REMOVE EXISTING ROOFING MATERIAL TO THE EXTENT REQUIRED, CONFORMING TO THE REQUIREMENTS OF THE PROJECT SPECIFICATIONS. 2. SAWCUT AND REMOVE EXISTING CONCRETE DECK (3" TEE BEAM FLANGE + 3" TOPPING SLAB) TO ENLARGE EXISTING OPENING FOR NEW DUCT. 53 E o 2 2 RECEIVED OF TUKWILA KEY PLAN SCALE: 1/64" = 1' -0" MAR 2 4 NA PERMIT CENTER No. I REVISION BY APP'D DATE PROJECT IIHUCER [mots 9/n/ G C00130007 SCALE AS NOTED ONE INCH AT FULL SIZE I ' 1 IF NOT ONE INCH. SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING PARTIAL PLAN 8c DETAILS DATE: MAY 2007 DRAWING NO: 2 S4.01 SHEET NO: OF 32 53 E 0O' m "ro Y4" STEEL STRAP (TYP - ALL AROUND) 2 "x2 "x , STEEL RETAINING ANGLE (TYP - ALL AROUND EACH SIDE) TYP )b" CLEARANCE ALL AROUND SAWCUT TO ENLARGE EXISTING OPENING IN EXISTING MASONRY UNIT WALL, CONCRETE WALL OR CONCRETE T -BEAM ROOF STRUCTURE (SIMILAR). SEE QBAYLINg 2 M3.02 - 8" CMU WALL HAS FULLY GROUTED CELLS w/ #4 VERTICAL REBAR CW 24 "; (3) #8 - IORIZONTAL AT BOND BEAM EVERY 4 FT TYPICAL MASONRY OPENING DETAIL • 1 SCALE: 3" = 1' -0" 2 A4.01 A No. REVISION BY APP'D DATE EXISTING OPENING MITER ANGLE JOINTS AT NEW OPENING 34" STEEL STRAP (TYP - ALL AROUND) 4 "x4 "4(" STEEL RETAINING ANGLE (TYP - ALL AROUND EACH SIDE) COMPRESSOR 1 ROOM TANK ALCOVE • • 11 0 EXIS -ING A::O.LSTICAL TI_E CE LING) EXISTING EL ECTRICAL (HAS! W STORAGE ROOM z 2, 6 1 COMPRESSOR ROOM ELEVATION �A1 SCALE: 1" = 1' -0" 2 54.01 NOTE: THIS IS A NON —LOAD BEARING WALL. I MARES Iva o Ia DESIGNED: Y FARJO �Cy 9 FARISS - BATEMAN GHEOCM J DAVIS SAWCUT TO ENLARGE EXISTING OPENING IN EXISTING MASONRY UNIT WALL. 12" CMI, WALL HAS FULLY GROUTED CELLS w/ #4 VERTICAL REBAR 24 "; (3) #8 IIORI7ONTAL AT BOND BEAM EVERY 4 FT RECEIVED MASONRY OPENING CITY OF TUKWiLA SECTION ( MAR 2 4 2008 SCALE: 3" = 1' -0" 2 S4.01 PERMIT CENTER NOTE: THIS IS A LOAD BEARING WALL. SCALE AS NOTED D CRIPPEN IBIS NO: 432692 & 432721 mac MAIM CONTRACT NO: C00130007 ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING CONSTRUCTION DETAILS DATE,' MAY 2007 DRAWING NO: 2 S5.01 SHEET NO: OF 33 53 m m r- EXISTING CEIL:NG COMPRESSOR ROOM OPENING FENCE BARRICADE ELEVATION SCALE: 1" = 1' -0" - INSTALL WOVEN WIRE MESH FENCE LX:S TING FLOOR TYP — — -- - EXISTING CFI; ING - EXISTING OPENING MITER ANGLE JOINTS AT NEW OPENING INSTALL WOVEN WIRE MESH FENCE (BEYOND) TRIM ANGLE TO FIT AT EXISTING CMU - WALL COMPRESSOR ROOM OPENING ELEVATION (-Br\ SCALE: 1" = 1' -0" 2 S4.01 EXISTING FLOOR TYP 1' -0" MITER ANGLE JOINTS AT CORNERS SEE ECM B/2 S5.02 < TYP FENCE BARRICADE SECTION %C1 SCALE: 3" = 1 ' -0" / FENCE BARRICADE SECTION %D1 SCALE: 3" = 1' -0" - 456" 114 "x1h "x)4s" CLIP ANGLE TYP - AT WALL FASTEN TO WALL WITH Y4" HEAVY -DUTY EXPANSION BOLTS, MIN EMBEDMENT 2 °. 3 PER SIDE v 10 GA WOVEN WIRE, 1 )4" DIAMOND MESH L iYz "x 11i "x i s" FRAME 14" THROUGH -BOLT FASTENERS ® 8" DC 1" X 3'4" FLAT BAR RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: Y FARJO DRAWN: RECOIOIEFIDED: J, D CRIPPEN A�WAIy PROJECT MANAGER: K MADODEN! APPROVED: B ISLER ,y IBIS NO: 432692 & 432721 .as =YEW CONTRACT NO: C00130007 SCALE: AS NOTED ONE INCH AT FULL SIZE 1' IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING CONSTRUCTION DETAILS LATE: MAY 2D07 DRAWING No- 2 S5.02 SHEET NO: OF 34 5,3 ROOF PLAN SCALE: 1/8"=1.-0" x x GENERAL NOTES: 1. PROTECT EXISTING ROOFING DURING CONSTRUCTION PER SPECIFICATION SECTION 07552. ul 2. ALL EQUIPMENT AND MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL CODES AND ORDINACES. C RAV'-Y V NT.LA'OR (2 TYP) REVIEWED FOR CODE (A.07M�P�CE bPR - 3 2008 Of Tukwila B LDINc DIVISION KEY NOTES: REMOVE EXISTING EXHAUST FAN AND BACKDRAFT DAMPER. EXISTING CURB TO REMAIN IN PLACE. MODIFY EXISTING CURB PER DETAIL 1 /2M5.01. INSTALL NEW EXHAUST FAN AND BACKDRAFT DAMPER WITH FLASHING PER DETAIL 2/A5.01. PROVIDE SHEET METAL ADAPTERS BETWEEN THE EXISTING CURBS AND NEW EXHAUST FANS TO ENSURE A WATER AND AIR TIGHT FIT. RECONDITION EXISTING VENTILATOR SURFACES PER ARCHITECTURAL SPEC SECTION 09900. RECEIVED CITY OF TUKVVI LA MAR 2 4 Z(1u8 PERMIT CENTER No. I REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: %�lp�� J. BICKERSTAFF CHECKED'. R. QUIST RECO A*DIDED. D. CRIPPEN PROJECT K. MADDEN APPROVED: B. ISLER IBIS NO: 432692/432721 110ac REQUEST: CONTRACT NO•. C0O13OCO7 1/8 " =1' -0" ONE INCH AT FULL SIZE 1 1 I IF NOT ONE INCH. SCALE ACCORDINGLY sin LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE FUEL AND WASH BUILDING ROOF PLAN DATE MAY 2007 i DRAWING NO: 2 M1.01 SHEET NO: DF 35 53 1- --- i A/2M3.01 AL2M3.01 IIIIH SIDE WALL EXHAUST FAN EF -9 B /2M3j01 a- - — - F1. l S�DE N WALLEF -10 EXHAUST B/2M3.01 �I ROOF PLAN SCALE: 1/8"--1'-0" GENERAL NOTES: EWED FOR E COMPLIANCE E FPA 70 �I APR - 3 City Of Tukwila E ILDIN DMVI _ ION 1. PROTECT EXISTING ROOFING DURING CONSTRUCTION PER SPECIFICATION SECTION 07552. 2. ALL EQUIPMENT AND MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL CODES AND ORDINAC ES. KEY NOTES: REMOVE EXISTING EXHAUST FAN. EXISTING DUCTWORK AND EXHAUST LOUVER TO REMAIN IN PLACE. SEE DRAWING 2M3.01 FOR NEW FAN INSTALLATION. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER A A A A No. REVISION BY APP'D DATE DESIGNED:" J. TURNER CJ PROJECT MANAGER: K. MADDEN SCALE: 1/8 " =1' -0" DRAWN: J. BICKERSTAFF omomm R. QUIST APPROVED: B. ISLER I/3/ IBIS NO: 432692/432721 WORK RFpyESF ONE INCH AT FULL SIZE I IF NOT ONE INCH, SCALE ACCORDINGLY RECOMMENDED: D. CRIPPEN ) C CONTRACT NO: C00130007 SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE FUEL AND WASH BUILDING FIRST FLOOR PLAN DATE MAY 2007 DRAWING NO: 2 M1.02 SHEET N6 OF 36 53 I EXPIRES 1I/O /O'y 13� O RC3= A CESS LJ EF -106 A L J 9 CRANE EF -109 EF -108 I �- I[ GENERAL NOTES: 1. PROTECT EXISTING ROOFING DURING CONSTRUCTION PER SPECIFICATION SECTION 07552. 2. ALL EQUIPMENT AND MATERIALS REMOVED DURING CONSTRUCTION SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND DISPOSED OF OFF SITE IN ACCORDANCE WITH LOCAL CODES AND ORDINACES. KEY NOTES: REMOVE EXISTING EXHAUST FAN AND BACKDRAFT DAMPER. EXISTING CURB TO REMAIN IN PLACE. INSTALL NEW EXHAUST FAN AND BACKDRAFT DAMPER WITH FLASHING PER DETAIL 1/2M5.01 AND DETAIL 1/A5.01. PROVIDE SHEET METAL ADAPTERS BETWEEN THE EXISTING CURBS AND NEW EXHAUST FANS TO ENSURE A WATER AND AIR TIGHT FIT. EF -107 REMOVE EXISTING EXHAUST GOOSE NECK, EXISTING CURB TO REMAIN IN PLACE. INSTALL NEW FLASHING. INSTALL NEW EXHAUST FAN AND EQUIPMENT CURB PER DETAIL 1/2M5.02. REMOVE EXISTING EXHAUST FAN, BACKDRAFT DAMPER AND CURB. MODIFY EXISTING ROOF OPENING. INSTALL NEW EXHAUST FAN, BACKDRAFT DAMPER AND EQUIPMENT CURB PER PLAN 1/2S4.01. REMOVE EXISTING EXHAUST FAN, EXISTING CURB TO REMAIN IN PLACE. INSTALL NEW FLASHING. INSTALL NEW EXHAUST FAN AND EQUIPMENT CURB PER DETAIL 3/2M5.01. REMOVE EXISTING EXHAUST FAN OEF -3, BACKDRAFT DAMPER AND CURB. PLATE OFF EXISTING ROOF PENETRATION AND PATCH ROOF P R DETAIL 3/2 A5.01 RECEIVED CITY OF TUKWI iM R 74 PERMIT CENTER DESIGNED: `gyp J. TURNER V ` DRAWN: J. BICKERST A PROJECT MANAGER K. MADDEN APPROVED: B. ISLER !,' IBIS NO 432692/432721 WORK REQUEST: - CONTRACT NO C00130007 sr..A F. 3/32 " =1 -0" ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING ROOF PLAN DATE MAY 2007 DRAWING NO: 2 M1.03 SHEET NO: OF 37 53 H FAN EF -9 PRESSURE WASH FAN CABINET AND SCREENED OPNG. C 2M3.01, EXISTING FAN CABINET TO REMAIN 66" (REF) FINISHED FLOOR WEST WALL ELEVATION %A1 SCALE: 3/8 " =1' -0" 2M1.02 EXTEND LOBE UNES TO EXTERIOR OF FAN CABINET. TERMINATE WITH ZERK FITTINGS IN AN ACCESSIBLE LOCATION. 39" (REF) SECTION SCALE: 3/4 " =1' -0" INSTALL BLANK OFF FLANGE (4 SIDES), SECURE TO EXISTING FAN CABINET W/ FASTENERS PER MANUFACTURERS RECOMMENDATIONS CENTER NEW EXHAUST FAN EF -9 INSIDE EXISTING CABINET PRESSURE WASH EXIS11NG BACKDRAFT DAMPERS PRIOR TO INSTALLING FAN EXHAUST FAN EF 10 PRESSURE WASH FAN CABINET AND SCREENED OPNG. 2M3.01, EXIS11NG FAN CABINET TO REMAIN -- FINISHED FLOOR 66" (REF) EXTEND LOBE LINES TO EXTERIOR OF FAN CABINET. TERMINATE WITH ZERK FITTINGS IN AN ACCESSIBLE LOCATION. EAST WALL ELEVATION SCALE: 3/8 " =1' -0" 2M1.02 39" (REF) INSTALL BLANK OFF FLANGE (4 SIDES), SECURE TO EXISTING FAN CABINET W/ FASTENERS PER MANUFACTURERS RECOMMENDATIONS CENTER NEW EXHAUST FAN EF -10 INSIDE EXISTING CABINET INSTALL NEW LOUVER. MANUF: GREENHECK MODEL: FSJ -402 -- PRESSURE WASH EXISTING BACKDRAFT DAMPERS PRIOR TO INSTALLING FAN SECTION (D-> SCALE: 3/4 " =1' -0" -- INSTALL NEW SHEET METAL FRAME RECEI E0 CITY OF TUKWILA MAR 2 4 10U PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: J. BICKERST R. OUIST m RECOMMENDm: D. CRIPPEN PROJECT MANAGER: K. MADDEN f '� APPROVED: /" 8. ISLER 4 I IBIS NO 432692/432721 MIX mwnc - CONTRACT NO: C00130007 SCALE: AS NOTED ONE INCH AT FULL SIZE t• IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE ELEVATION AND SECTIONS DATE MAY 2007 DRAWING NO: 2 M3.01 SMUT NO: OF 38 53 8 m POC, RELOCATED 3" HWS 32 "x32" DUCT UP TRANSITION TO 24 "x48" SUPERVISOR OFFICE IN MEZZANINE ABOVE EXISTING 3" HWR ABOVE POC, RELOCATED 3" HWS EQUIPMENT i200M COMPRESSOR ROOM EQUIPMENT ROOM PARTIAL PLAN %11 SCALE: 1/2"=1'-0" - KEY NOTES: REMOVE APPROX. 6 LF OF EXISTING 3" HWS (HEATING WATER SUPPLY) PIPING AND INSULATION JACKET. COORDINATE SHUT DOWN WITH BASE STAFF. RELOCATE 3" HWS PIPING BELOW EXISTING 3" HWR (HEATING WATER RETURN) PIPING FOR INSTALLATION OF NEW DUCTWORK TO EXHAUST FAN EF -109. FOR RELOCATION OF CONDUITS AND LIGHT FIXTURE, REFER TO ELECTICAL DRAWINGS. EF 109 ENLARGE ROOF OPENING TO 34"x34", SEE %Th 2S4.01 32 "x32" DUCT UP SUPERVISOR OFFICE PIPING MODIFICATIONS PHOTO SCALE: NTS - -- I SECTION SCALE: 1 /2 " =1 ' -0" NEW 24'x48" E REPLACES EXIST 16 "x48" GRILLE, SEE 2S4.01 EXISTING 3" HWR EXISTING 3" HWS COMPRESSOR ROOM EQUIPMENT ROOM EXISTING 3" HWR PIPING RELOCATED 3" HWS PIPING RECEIVED CITY OF TUKWI A MAR 2 4 2[108 PERMIT CENTER FIN. FLR. SECTION SCALE: 1/2 " =1' -0" No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN J. BICKERSTAFF�" CHECKED: RECOMMENDED: *. R. QUIST PROJECT MANAO K. MADDEN / APPROVED: 7. B. ISLER �' es NO: 432692/432721 WORK REQUEST: - CONTRACT NO: SCALE: AS NOTED ONE INCH AT FULL SIZE 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: ImiEs II/Q /0-1 D. CRIPPEN C00130007 King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE EQUIPMENT ROOM PLAN AND SECTIONS DATE: MAY 2007 DRAWN° 2 M3.02 SHEET NO: OF 39 53 I0 11/G/ el ROOF MOUNTED CENTRIFUGAL EXHAUST FAN - DUCTWORK ROOF MOUNTED CENTRIFUGAL EXHAUST FAN 7 MESH BIRDSCREEN TYP ROOF EXHAUST FAN ON EXISTING CURB DETAIL (11 SCALE: NTS - -- EXISTING BUILT -UP ROOF DUCTWORK TYP ROOF EXHAUST FAN WITH NEW CURB DETAIL SCALE: NTS SECURE FAN TO CURB WITH 1 1/2" LONG FASTENERS AT 12" OC (MINIMUM 2 PER SIDE, AS REQUIRED) EXISTING BUILT -UP ROOF EXISTING ROOF CURB SEE NOTE AND A5.01 A5.01 BACKDRAFT DAMPER AS SPECIFIED. BUILD -UP CURB W/ SPACER AS REQUIRED TO ACHIEVE A MINIMUM HEIGHT OF 8" ABOVE FINISHED ROOF. MESH BIRDSCREEN SECURE FAN TO CURB WITH 1 1/2" LONG FASTENERS AT 12" OC (MINIMUM 2 PER SIDE, AS REQUIRED) 8" PREFABRICATED ROOF CURB, SEE (-3- A5.01 SEE ARCHITECTURAL DRAWINGS FOR ROOF OPENING BACKDRAFT DAMPER AS SPECIFIED. BIRD SCREEN PLAN EXHAUST FAN FLEXIBLE CONNECTION STAINLESS STEEL SCREWCLAMP (TYP) 10 "0 GALVANIZED STEEL CURB FLASHING, STAINLESS STEEL SEE A5.01 EXISTING 16 "x13 "x 7 "H CURB EXISTING DUCTWORK, SEE 7' -O' 2M5.02 r • ELEVATION EXHAUST FAN EF -106 DETAIL SCALE: 1"=1'-o" 2M1.03 11"0 DISCHARGE DUCT, ALUMINUM ALLOY (14 GAUGE) TRANSITION DUCT, ALUMINUM ALLOY 1 1 -3/4"x11" TO 10" DIA. (14 GAUGE) BACKDRAFT DAMPER W/ FLANGED CONNECTIONS DRAIN HOLE w/ REMOVABLE PLUG EXHAUST FAN NEW 8 "H EQUIPMENT CURB, SEE / '1 &( 2M5.03 1A4.01 EXISTING BUILT -UP ROOF MECHANICAL FASTENERS (TYP) EXISTING DUCTWORK TYPICAL DUCT CONNECTION DETAIL SCALE: NTS - -- EXISTING ROOF CURB 16 GAUGE PLATE SIZED FOR DUCTING TO EXHAUST FAN RECEIVED CITY OF TUKW1LA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: J. TURNER DRAWN: J. B1CKERSTAFF CHECKED R. QUIST RECOMMENDED: D CRIPPEN PROJECT MANAGER: K. MADDEN / APPROVED: B. ISLER +/ IBIS NO: 432692/432721 WORK wam• - CONTRACT NO: C00130007 SCALE AS NOTED ONE INCH AT FULL SIZE '" IF NOT ONE INCH. SCALE ACCORDINGLY SRE LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MECHANICAL DETAILS DATE: MAY 2007 DRAW $C MM 2 M5.01 SHEET NO DF 40 53 Ab Sd fog \ BIRD SCREEN PLAN EXHAUST FAN FLEXIBLE CONNECTION STAINLESS STEEL SCREWCLAMP (TYP) 8 "0 GALVANIZED STEEL CURB FLASHING, STAINLESS STEEL SEE A5.01 7' -0" EXISTING 18 1/2 "x 18 1 /2 "x 8 "H CURB EXISTING DUCTWORK, SEE 2M5.01 -r 9 "0 DISCHARGE DUCT, ALUMINUM ALLOY (14 GAUGE) TRANSITION DUCT, ALUMINUM ALLOY 10 -1/8"x10" TO 8" DIA. (14 GAUGE) BACKDRAFT DAMPER W/ FLANGED CONNECTIONS ELEVATION EXHAUST FAN EF -108 DETAIL SCALE: 1"=1'-0" 2M1.03 DISCHARGE DUCT STACK HEAD NOTE: DISCHARGE DUCT AND STACK HEAD, ALUMINUM ALLOY (14 GAUGE), WELDED CONSTRUCTION. SECTION SCALE: 1 -1/2"=1. -0" - -- 5/8 "DIA. SS BOLT & WASHER 1 1/2 "DIA. NON - METALIC SPACER, 1/2" THICK LOCK NUT & WASHER TACK WELDED TO DISCHARGE DUCT EXHAUST FAN NCW 8 "H EQUIPMENT CURB, SEEn & (-7-0\ 1 2M5.03 1A4.01 DRAIN HOLE W/ REMOVABLE PLUG DEMOLITION EXISTING FAN EF -108 PHOTO SCALE: NTS 2M1.03 EXISTING 12x12" BATTERY ROOM DEMOLITION NOTES: REMOVE EXISTING DUCT TRANSITIONS, EXHAUST FAN EF -8 AND MOTOR AS SHOWN IN HATCHED AREA. FOR REMOVAL OF CONDUIT AND CONTROLS, REFER TO ELECTICAL DRAWINGS. POC, NEW 12x12" EXHAUST DUCT MAINTENANCE BAY ELEVATION SCALE: 3/4 " =1' -0" - -- FIN. FLR. EXISTING 12x12" DUCT UP TO EF -108, SEE (9 POC, NEW 12x12" EXHAUST DUCT RECEIVED CITY OF TUKWILA, MAR 2 4 7008 PERMIT CENTER No. REVISION BY APP'D DATE IWIRES 11/0/on DESIGNED: J. TURNER DRAWN: 4'4 J. BICKERSTAFF CHECKED: R. QUIST RECOMMENDED D CRIPPEN PROJECT K MADDEN APPROVED: B ISLER 18IS NO 432692/432721 MOW REQUEST: CONTRACT NO C00130007 SCALE: AS NOTED ONE INCH AT FULL SIZE I ' I IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MECHANICAL DETAILS DATE: MAY 2007 DRAWING NO: 2 M5.02 SHEET NO: DF 41 53 12 GA. STEEL CURB FLASHING DIM. A DIM. B + + 4- 4- 4- (TYP. 4) + PLAN EQUIPMENT CURB DETAIL SCALE: 2"=1.-0" 2M5.01 2M5.02 1 A4.01 NOTE. VIBRATION SPRING MOUNT (TYP 4), SEE DETAIL 2 SEE TABLE-A FOR SPRING MOUNT DIMENSIONS. CURB FRAMING, FLASHING AND ATTACHMENT SEE 2/A5.02 VIBRATION SPRING MOUNT W/SEISMIC SNUBBERS VIBRATION MOUNT DETAIL -2- SCALE: NTS TABLE A FAN NO. "A" DIMENSION "B" DIMENSION EF- 106 16" 20 3/8" EF- 108 13 1/2" 12" NOTE: 1. DIMENSIONS SHOWN ON TABLE-A ARE FOR EXHAUST FANS LISTED ON DRAWING 2M6.01. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: R. QUIST RECOMMENDED: EXPIRES I 1/9/ 01 D CRIPPEN PROJECT MANAGER: K MADDEN/ APPROVED: B ISLER IBIS NO: 432692/432721 Nom =NEM CONTRACT NO: SCALE: AS NOTED (e; C001 30007 ONE INCH AT FULL SIZE 1. IF NOT ONE INCH, SCALE ACCORDINGLY King County SITE LOCATION NO: Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MECHANICAL DETAILS mm. MAY 2007 DRAWING MO, 2 M5.03 SHEET NC: OF 42 53 0 a EXHAUST FAN SCHEDULE MARK NO. SERVED CFM FAN SPEED (RPM) EXT SP (IN WC) dBA1 MOTOR DRIVE ASSEMBLY EXISTING WEIGHT (LBS) NEW WEIGHT (LBS) BASIS OF DESIGN EXISTING CURB MOTOR HP BHP VOLT PH HZ SIZE HT. EF -1 FUEL -WASH BUILDING GENERAL EXHAUST 1820 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 81 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 25" Si" EF -2 FUEL -WASH BUILDING GENERAL EXHAUST 1820 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 81 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 25" 64" EF -3 FUEL -WASH BUILDING GENERAL EXHAUST 1820 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 B1 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 25" 63" EF -4 FUEL -WASH BUILDING GENERAL EXHAUST 1820 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 81 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 25" 64" _ EF 5 FUEL -WASH BUILDING GENERAL EXHAUST 1820 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 $1 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 25" 64" EF-6 FUEL -WASH BUILDING GENERAL EXHAUST 1820 860 0.25 59 1/4 0.21 120 1 60 DIRECT 75 81 GREENHECK G -170 -C WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 25 6" EF -7 FUEL -WASH BUILDING TOILET EXHAUST 225 1050 0.125 45 1/40 0.02 120 1 60 DIRECT 25 26 GREENHECK G -080 -E WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 1•• 84" 53 EF-8 FUEL -WASH BUILDING TOILET EXHAUST 460 1300 0.125 50 1/25 0.04 120 1 60 DIRECT 25 26 GREENHECK G -090 -G WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 184" 64" EF -9 FUEL WASH BUILDING SIDE WALL FAN 35800 680 0.250 83 7 1/2 6.0 480 3 60 BELT 600 590 GREENHECK SBC- 3L54 -75 WITH TEFC MOTOR EF -10 FUEL WASH BUILDING SIDE WALL FAN 33380 680 0.375 83 7 1/2 6.0 480 3 60 BELT 600 590 GREENHECK SBC- 3L54 -75 WITH TEFC MOTOR EF -106 MAINTENANCE BUILDING WELD SHOP EXHAUST 1000 2583 3.0 67 1 0.82 480 3 60 BELT 120 140 GREENHECK 210 SWB SERIES 200, WITH ODP MOTOR 16x13" 17" EF 107 MAINTENANCE BUILDING TOILET 103 EXHAUST 140 1050 0.25 45 1/40 0.02 120 1 60 DIRECT 25 26 GREENHECK G -080 -E WITH BACKDRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 184" 8" EF -108 MAINTENANCE BUILDING BATTERY ROOM EXHAUST 600 945 0.5 58 1/4 0.12 120 1 60 BELT 25 120 GREENHECK SFB -9, WITH ODP MOTOR, TYPE 8 SPARK RESISTANT CONSTRUCTION AND EPDXY FINISH 183' 8" EF -109 MAINTENANCE BUILDING BOILER ROOM EXHAUST 13810 597 0.75 d2_ 5 3.44 480 3 60 BELT 250 403 GREENHECK GB- 360 -50 WITH BACK DRAFT DAMPER, BIRDSCREEN AND ODP MOTOR 34" 11" 1. NOISE RATING PER ARI 270. GRILLES /REGISTERS /DIFFUSER SCHEDULE MARK NO. MAX CFM FACE SIZE (IN) NECK SIZE (IN) CRITERIA (MAX) - MANFACTURER AND MODEL REMARKS NOISE CRITERIA (NC) TP (IN WG) EG -1 13810 24x48 22x46 35 0.15 TITUS 50R W/ 1 "x1 "xl" ALUMINUM CORE GENERAL NOTES: 1. VERIFY SIZES OF ALL EXISTING ROOF CURBS BEFORE ORDERING NEW EXHAUST FANS. 2. WHERE THERE ARE DIMENSIONAL DIFFERENCES, PROVIDE SHEET METAL ADAPTERS BETWEEN THE EXISTING CURBS AND NEW EXHAUST FANS TO ENSURE A WATER AND AIR TIGHT FIT. RECEIVED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE DESIGNED: J. TURNER PROJECT MANAGER. K. MADDEN f �' CAt F. AS NOTED DRAWN: J. BICKERSTAFF •V CHECKED: /J� R. OUIST ICJ( RECOMIAENDElk D. CRIPPEN APPROVED: 8. ISLER 47 IBIS NO: 432692/432721 KOK MOUES, - CONTRACT NO 000130007 ONE INCH AT FULL SIZE IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE EQUIPMENT SCHEDULE OA'E: MAY 2007 DRAWING NO; 2 M6.01 SHEET NO: CIF 43 53 X ROOF PLAN SCALE: 1/8"=1. -0" LEGEND: EH MOTOR STARTER DISCONNECT SWITCH K COMBINATION MOTOR STARTER J CONDUIT DOWN 0, EXHAUST FAN MOTOR ED FOR E �.MPLIANCE CON 70 - NEC < AEI, -3 2008 City 9f Tukwila E ILDIN DIVI ION CONSTRUCTION NOTES: DISCONNECT EXISTING FAN MOTOR FOR REMOVAL. CONNECT NEW FAN MOTOR TO NEW DISCONNECT SWITCH. INSTALL NEW THERMAL MOTOR SWITCH IN NEMA TYPE 4 WITH HANDLE GUARD AND PADLOCK CAPABILITY. INSTALL ASSOCIATED CONDUIT AND WIRING. INSTALL NEW SPECIFICATION GRADE GFCI OUTLET IN "FD" CAST IRON DEVICE BOX WITH WEATHERPROOF WHILE IN USE COVER. INSTALL CONDUIT AND WIRING. (TYP 3 PLACES) INSTALL CONDUIT AND WIRING TO DESIGNATED CIRCUIT VIA THE EXHAUST FAN CONTROL PANEL. SEE DRAWING 2 E1.02 FOR LOCATION. GENERAL NOTE: 1. EXISTING HOME RUN CONDUITS CO StEEIVED THE ROOF TOPPING SLAB SHA1.4 It�1" ABANDONED IN PLACE WITH THL� ��DTt- ��� ENDS CUT OFF AND CAPPED. NEW HOME RUN CONDUITS SHALL BE INSTALLur1 4E R^ �fl�l� THE CEILING. I Hij `i l 1 PERMIT CE1\ I ER No. REVISION BY APP•D DATE DESIGNED: L McFARLAND CH C. REYNOLDS L' RECOMMENDED: D. CRIPPEN PROJECT MANAGER: K. MADDEN I APPROVED: B. ISLER/.) 432692/432721 IRMA RDA16F. CONTRACT NO: C03130007 1/B " =1 —o" ONE INCH AT FULL SIZE IF NOT ONE INCH. SCALE ACCORDINGLY STE LOCATON NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE FUEL AND WASH BUILDING ROOF PLAN LATE MAY 2DD7 DRAWING NO: 2 E1.01 SHEET NO DF 44 53 1 1 1 1 1 1 1 0 ri PANEL 'S' TO PANEL 'T' CKTS 38,40.42 CRAVI—Y VENT'L A TOR (2 TY'') ROOF (TRANSFORMER T3 (PANEL 'U' PANEL 'T' AcENT AIOR :n r PANEL i CKTS 37,39,41 BOLER -R.,OM -_i REC.AIM '4NR. SEE DETAIL 1 PANEL 'T' PANEL 'U' EXHAUST FAN CONTROL PANEL PANEL 'P3' DETAIL SCALE: NONE PLAN SCALE: 1/8 " =1' -0" (1) 1" GRS CONDUIT (3) 3 AWG TNWN CU (1) 8 AWG CU GROUND TRANSFORMER 'T3' (1) 1 -1/2" GRS CONDUIT (4) 2 AWG TNWN CU (1)6 AWG CU GROUND RECEDED CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER CONSTRUCTION NOTES: REPLACE EXISTING PHOTOELECTRIC SENSOR. USE LONG RANGE DIFFUSE SENSOR AB 42GRP -9D43, BANNER Q45BW13DX OR APPORVED EQUAL. REMOVE EXISTING MOTOR STARTERS AND CONTACTORS FOR EF -10 AND EF -11. REMOVE ASSOCIATED CONDUIT AND WIRING. INSTALL NEW PANEL P3 AND INSTALL NEW TRANSFORMER T3, 30KVA, 4-80-208Y/120V NEMA TP -1, GROUND TRANSFORMER PER NEC 250.30. DISCONNECT EXISTING FAN MOTOR FOR REMOVAL. CONNECT NEW FAN MOTOR TO NEW COMBINATION STARTER. INSTALL NEW COMBINATION MOTOR STARTER, ASSOCIATED CONDUIT AND WIRE. INSTALL RUN SIGNAL WIRING BETWEEN MOTOR STARTERS AND EXHAUST FAN CONTROLS PANEL. No. REVISION BY APP'D DATE !WIRES 6/13/0 DESIGNED. L. MCFARL'ND PROJECT MANAGER: K. MADDEN APPROVED: B. ISLER' B! MA7tABLE CHECKED: 1815 NO: 432692/432721 C. REYNOLDS YORK REQUEST: RECOMMENDED: A CONTRACT NO: D CRIPPEN ;� � C00130007 1/8" = 1. -0,. ONE INCH AT FULL SIZE 1- IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE FUEL AND WASH BUILDING FIRST FLOOR PLAN DATE: MAY 2007 DRAWING NO 2 E1.02 SHEET NO: DF 45 53 EF -105 Ei F r- I i LJ HI EF- 109 TO EXHAUST HOOD SWITCH AND LIGHT IN MACHINE ROOM. v I v EF -106 EF -108 P1 -26 TO THE THERMOSTAT IN COMPRESSER ROOM PB2 -2 X El • V LEGEND: Y I 77, J MOTOR STARTER DISCONNECT SWITCH COMBINATION MOTOR STARTER J CONDUIT DOWN `Q` EXHAUST FAN MOTOR s THERMAL MOTOR SWITCH [, u CONSTRUCTION NOTES: Iv v DISCONNECT EXISTING FAN MOTOR. REMOVED ASSOCATED CONDUIT AND WIRE. DISCONNECT EXISTING FAN MOTOR FOR REMOVAL. CONNECT NEW FAN MOTOR TO NEW STARTER. SEE DRAWING E5.01 DETAIL 1 OR DETAIL 2 INSTALL NEW NEMA 4X COMBINATION MOTOR STARTER, CONDUIT AND WIRING. SEE DRAWING E5.01 DETAIL 2 INSTALL NEW NEMA 4 THERMAL MOTOR SWITCH, CONDIUT AND WIRING. INSTALL NEW SPECIFICATION GRADE GFCI OUTLET IN "FD" CAST IRON DEVICE BOX WITH WEATHERPROOF WHILE IN USE COVER. INSTALL CONDUIT AND WIRING. (TYP 4 PLACES) GENERAL NOTE: RECEIVED CITY OF TUKWILA MAR 2 4 2008 EXISTING HOME RUN CONDUITS CONCEALED IN THE ROOF TOPPING p SLAB SHALL BE ABANDONED IN PLACE WITH THE EXPOSED ENDS C1I ERR T CENTER OFF AND CAPPED. NEW HOME RUN CONDUITS SHALL BE INSTALLS UNDER THE ROOF. No. REVISION BY APP' D DATE I DARES 0/13/ Vff DESIGNED: L. UcFARLAN rerv CHECKED C. REYNOLDS RECONDAENOED: r D CRIPPEN N` PROJECT IMAGER", K. MADDEN / l / APPROVED: B. ISLER 1812 No 432692/432721 WO. MOUES,: - SCALE: 3/32 " =1 -0" ONE INCH AT FULL SIZE 1- 1 { IF NOT ONE INCH. SCALE ACCORDINGLY CONIRlCT NO: C00130007 SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING ROOF PLAN GATE: MAY 2007 ORAWIN° NO: 2 E1.03 SHEET NO 0, 46 53 r I- STORAGE 0112 E 11 QFLIU 0109 r OEFGE 01'0 0101 L _ SURE OS RAGr PAR'S ROOM V119 t-. J 1,R4 5-lop V111 BAY tF BL0 SHOP 121 Iu vOM °RESSOR RQQ V1'2 WOMEN 1"0 FIRST AIL RM V1 11 4EN V109 PASSAGE 121 ACETYLENE SMAGt 1'6 OXYGEN STORAGF 117 BRAKE ROOM V126 BA" 2 STF AM GLEANING 125 AREA V105 033M SYQRAGE 1'9 BA" 3 1'l BAY 4 BAY 17 BA's 16 SEE DRAWING '2 E4.01 GSASS5 SYOP 104 BAYS BAY 6 ILI BAY '5 BAY '4 BA" '3 BAY 12 PNL "C" C: . J N EWDFOR E CO ° PLIANCE A 7' a NEC APR - 2008 ty Of Tukwila INCD : ION CONSTRUCTION NOTES: REMOVE EXISTING STARTER, CONTROLS, DISCONNECT ASSOCIATED CONDUIT AND WIRING FOR EF -106 (LABELLED MEF -10). CONNECT EXISTING EXHAUST HOOD CONTROL SWITCH AND HOOD LIGHT TO STARTER FOR NEW FAN EF -108. SEE DRAWING 2 E1.03 FOR FAN AND DISCONNECT LOCATION. SEE DRAWING 2 E6.04 FOR SCHEMATIC. REMOVE EXISTING STARTER, CONDUIT AND WIRE FOR EF -107 (LABELLED EF -12). RECEIVED CITY OF TUKVVILA MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE I°MIRES 6 /13/Op RECOMMENDED: D. CRIPPEN King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE E XHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING FIRST FLOOR PLAN DATE: MAY 2007 DRAWING NO 2 E1.04 SHEET NO: OF 47 53 • • Fl FC -RIc s -RVC- ROOM V1 1 -7 C/8" P 0UIPMENFT �oov V10/ l 1 - - -- _,\,,___ 1 / COMPRES: OR ROOM v' "1 CONE RM V'06 0 C7 SHOP V "01 SEE PARTIAL PLAN 1, 2 E4.02. TO PNL P1 - #20 EXTEND CONDUIT UP TO THERMAL MOTOR SWITCH AND OUTLET ON ROOF. LEGEND: MOTOR STARTER DISCONNECT SWITCH COMBINATION MOTOR STARTER CONDUIT DOWN EXHAUST FAN MOTOR CONSTRUCTION NOTES: DISCONNECT EXISTING FAN MOTOR FOR REMOVAL. REMOVE MOTOR DISCONNECT. NEW FAN TO BE RELOCTED ON ROOF. (EF -108) SEE DRAWING 2 E1.03 WORK AREA KEY PLAN CEIVED 1 OF TUKWIL4 MAR 2 4 2008 PERMIT CENTER No. REVISION BY APP'D DATE ONE INCH AT FULL SIZE 1• IF NOT ONE INCH, SCALE ACCORDINGLY SfTE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE MAINTENANCE BUILDING BATTERY RM. PLAN & SEC DATE MAY 2007 DRAWMO NO: 2 E4.01 smarm Dr 48 53 POC, RELOCATED 3" HWS 32 "x32" DUCT UP TRANSITION TO 24 "x48" SUPERVISOR OFFICE IN MEZZANINE ABOVE 7 EXISTING 3 " -HWR- ABOVE POC, RELOCATED 3' HWS EQUIPMENT ROOM COMPRESSOR ROOM EQUIPMENT ROOM PARTIAL PLAN (-711 SCALE: 1/2 " =1' -0" - -- r• �11 EXISTING RECEPTACLE SECTION SCALE: 1/2"=1' -D" CONSTRUCTION NOTES DISCONNECT AND "FMDDRAR'LY REMOVE LUMINAIRE, JSE CARE -0 or DAMAGE 1 UM■NAIRC. REINSTALL JVINAIRE AP°ROX. 8 INCHES LOWER. AFTER DLO WORK IS F!NSHED. PJL I BACK EXIST'KG 'WIRING AN) REMOVE E XIST.NG C: ;NDUI "S. INSTAL_ NEW RELOCA -ED CCND1,I' AND A R.NG REMOVE EX ST'NG D SCONNECT SWITC -• AND ASSOCIA -ED COND'U.1 AND W R NC. REMOVE MO `OR STARTER AND ASSOCIA ED COWL, AND WRNG. REMOVE E.XIS'iNG THERMOSTAT. INSTAL NEW THERMOS-AT AND AND ASSOC ATED CDNDJ T ANC WIRING. NEW 24 "x48" EG -1 REPLACES EXISTING 16 "x48" GRILL EXISTING 3•' HWR EXISTING 3" HWS RECEi . ED CITY OF TUKWIL4 MAR 2 4 2008 PER`. T CENTER No. REVISION BY APP'D DATE I DPIRES 5/13 /0E DESIGNED: PROJECT MANAGER L. McFARLANA. K. MADDEN/ D ✓ . /. !� /v' APPROVED: `Y. MAR B. ISLER (A." CHECKED: /I JBIS NO: C `''432692/432721 C. REYNOLDS =ft REQUEST: - RECOMMENDED: CONTRACT NO: D. CRIPPEN ;{ C00130007 AS NOTED ONE INCH AT FULL SIZE 1. IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE EQUIPMENT ROOM DETAIL AND SECTIONS DATE: MAY 2007 DRAWING NO: 2 E4.02 SHEET NO: OF 49 53 FUEL /WASH BUILDING 1dQE MAIN DISTRIBUTION PANEL (MEZZANINE ABOVE WOMEN'S LOCKER ROOM) 1200A BUS, 480/277V, 30, 4W 114 113 112 111 b^ )BOA ) 80A 110 I9 b ) 125A ) 100A TO 51 U 508 SEE DWG E12C 250KCM CU, 5000V, 4'C MV -90 SHIELDED & JACKETED 16 15 14 0 )1°13A 0 )15°A 0 ) 100A ) 4160V, UNDERGROUND CONDUITS 51 -U -507 51 -U -500 LOAD INTERRUFWR SWITCH, 4.8 KV 51 -Y -405 ITT\ 600A WITH GND FAULT TRIP EJI -125E RATING LIMITING POWER FUSES 500KVA 4160, 480Y/277V TRANSFORMER 13 2 I1 ) 150A g. (0 c3 51 -Y -501 4- CYCLONE WEST CYCLONE EAST BUS WASH CONTROL PANEL WEST 4-16, 16 G, 1 1/4•C 3 f 3 AWG, 8 AWG CND. 1' C. CRS 30KVA - T1 ▪ 480- 208Y/120V C1 3OKVA 480- 208/120V 45KVA 48O : 208Y/120V (4) 2AWC, 8 AWG GND 1 -1/2' C. CRS PANEL 100A BUS 100A MCB 10 51 -U -505 IN UNIT REPAIR SEE DWG E12B RECEIVED CITY OF TUKWILA MAR 2 4 2008 PER;. ::T CENTER ADDED PWR PNL & XFMR TO DIST. PNL MDP J DM LM REVISION BY APP'D 12/06 DATE DOPES 6 /u /08 DESIGNED: L. McFAR PROJECT MANAGER K. MADDEN APPROVED: B. ISLER CHECf®: IBIS NO: 1 X11 �-• 432692/432721 C. REYNO wda =OEM - RECOMMENDED: f CONTRACT NO: SCALE N /A D CRIPPEN 000130007 ONE INCH AT FULL SIZE '• I IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT SOUTH BASE FUEL /WASH BUILDING SINGLE LINE DIAGRAM DATE: MAY 2007 DRAWING NO: 2 E6.01 SHEET NO: OF 50 53 ELECTRICAL PANEL SCHEDULE PANEL P1 BLDG VEH. MAINT BASE SOUTH DATE Aug -04 TYPE Sq. D. NOOD LOCATION 1st Floor. Mech. Corridor B -5 SURFACE OR FLUSH SURFACE FEEDERS 4- 82.1- 06Gnd.' 1/2"C MAIN BKR. 100A FROM PANtL JA. (.INCUII S 1. 3. b VIA xl-MH RATING 225A. 208Y/120V. 3PH.4W SHORT CKT .RTG.ISym 10.000AIC 30KVA REF.DWGS. REVISION(s) ENGINEER As Built JS PELMAN (208- 283 -3713) REVISED CKT DATE REVISED JOB NO. Jul -34 (CMS) •RCUIT FRAMES & AMPS WIRE SIZE DESCRIPTION HP AMPERES LOCATION a 1 b c la 20A! 1P 012 (3) RECEPTACLES 4.5 •. Y PARTSAM124 3b 20A/ 1P 412 (4) RECEPTACLES 012 6.0 ; ' , , s 6o 20A/ 1P 012 (4) RECEPTACLES 20611P _ , 8.0 FOREMANS CFRaCE 107 7e 20A1 1P 012 (4) RECEPTACLES 6.0 • . ''•, - FCREI.IAWS CFFICE 107 9b 20A/ 1P 012 (4) RECEPTACLES _ 6.0 " SUPIASCRS CFRCE 110 20A/ 1P 012 (4) RECEPTACLES ' •- , ' Irspert• F9101 6.0 MACHINE SHOP 123 13a 20A/ 1P 412 (4) RECEPTACLES 6.0 45 - s ELECTRCM(SSHOP129 15b 204! IP 012 Hot Water Boiler B -101 6.0 2.0 t Chassis Slop 104 17c 20A/ 117 412 DDC • ti 6.0 .: 19a 20A/ 1P 412 (8) RECEPTACLES 4.5 , , . 21b 20A! 1P 012 (4) RECEPTACLES 412 6.0 •. - 6.0 23c 20A/ 1P 012 (4) RECEPTACLES 20611P 412 6.0 PARTS ROOM 124 25a 20A1 1P 412 FIRE SMOKE DAMPER 3.0 15/511P ... (4) RECEPTACLES 27b 20A/ 2P ., SWITCHED NEUTRAL Chassis Shop 104 25a 1 - 29c i VAP -101 113 7.2 2401 V S!. �.} . .I .. J`^i t k'' • . - • - --'. .. ^' .. f• 1 '., :. y .. . 31a 20/IP 412 SE EDLTS FANTAN( 13.0 ... - So. Wash Shed 33b d161 1P 412 (1) RECEPTACLE . .. 15 C.. So. Wash Shed 35c Z661 1P 412 (1)RECEPTACLES . �., • 15 So. Wash Shed 37c 1 .. . 39c 2a 1 MAIN BREAKER 16.7 i 1-_'- 4b 30A/ 3P (3)4 10 BATTERY CHARGER 16.7 CCL A•7 6c 1 u. . " �. : :. -' -.r . ^Inspection 2a , J.: 7b Sa 20A/ 1P 012 UGHT 1.0 012 ({z�RR�J ACLED BevatorPi 10b 20A/ 1P 012 (4) RECEPTACLES _ 6.0 BevatorPf 124 20A/ 1P 412 (4) RECEPTACLES 2130/ 1P 412 Fuel Management Lunch Rm 201A 14a 1 106 6.5 412 SUMP PUMP CONTROL . • 16b 60A1 3P (3) 4 4 GBV SET PANG • - , . 11.0 1/3', Generator Bldg N. of Maint. 18c 1 14a ,. _. 14.6 20a 20A/ 1P 012 EF-108 E70-I. FAN RECPT. 114 7.3 BATT. ROOM ROOF 22b 20A/ 1P 012 FIRE ALARM PANEL - 3.3 .. 24c 20A/ 1P 412 UH- 105 2Q6/ 1P 412 (S)RCCFWPG.ES 4S 26a 20A/ 1P 012 RECEPTACLE(AHU- 105.106,107) 2361P 412 SPARE 28b 20A/ 21) (2)4 12 PROPANE P -103 1 HP : -_ •:. 13.0 iT40 • . 300 L Roof. Col C -13 (Rm 103) SW NEUTRAL • - . 2Eb I - . 30c BIN 1P NMIM ,.. illMINNIMPRIMIIIIMIRIONIMINIIIIIIIIIIIIMINEREIMMINIMIMMINII ROTEMINENSIUMMINIMIMAIIIMINIMINIMISMIIIIIIIMIERNICONIZONNIMMISISI 145 Roof. Col B -10 32a 206/1P 412 SHED LTG, HOTWTRFOR 13.0 • . No. Wash Shed 34b 84.5 73.0 62.4 TOTAL AMPS CIRCUIT FOR REPLACED FAN AND CONTROLS. NE ELECTRICAL PANEL SCHEDULE PANEL C BLDG VEH. MAINT BASE SOUTH DATE Aug.04 TYPE Sq. 0, NOOB LOCATION INSPECTION AREA COL B -3 SURFACE OR FLUSH SURFACE FEEDERS MAIN BKR. 100A FROM PANEL "A ", CKTS 20.22.24 via 30kVA XFMR RATING 1 DOA. 208Y/120V. 3PH.4W SHORT CKT. RTG..Isym REF.DWGS. REVISION(s) As Stott ENGINEER JS PELMAN (206- 263 -3713) REVISED CKT DATE REVISED JOB NO. Jul-04 (CMS) aROJIT FRAMES & AMPS WIRE SIZE DESCRIPTION HP AMPERES LOCATION a b I c 1a 2136/ 1P 412 IJa•fT1NG 10 .. LIEeUM* Tume1 3b 20611P 012 (4) ORCP RECEPTACLES 6A '_. . Inspection Fi 101 Sc 20611P 112 (4) DRCP RECEPTACLES 6.0 Inspection Pi101 7a 20441P 412 (DI.) (4) RECEPTACLES 60 '.. y, , Inspection F9 101 9 6 20611P 012 (DL.) ( 4 ) R B Z E P T A O _ E S 6.0 ' •- , ' Irspert• F9101 11c 20611P 012 DL) (3) RECEPTACLES . . , 45 Inspection Fi 101 13a 20611P 112 (4) DROP RECEPTACLES 6.0 t Chassis Slop 104 15b 204 1P 412 (4) DROP RECEPTACLES • ti 6.0,.. .: Chassis Shop 104 17c 2061 1P 410,412 DGE RIC RUGHTINGC VTRCL 1.0 ROZF, RAG 19a 20611P 412 (4) RECEPTACLES 6.0 . ' •,, _' Chassis Shap 104 21b 20611P 412 (2) RECEPTACLES 3.0 .. • Chassis Slop 104 23o 15/511P 412 (4) RECEPTACLES ., 6.0 Chassis Shop 104 25a 1 - Z7b 2401 V - SPARE 28c 1 - 31a 20/IP 412 SE EDLTS FANTAN( 13.0 ... - So. Wash Shed 33b d161 1P 412 (1) RECEPTACLE . .. 15 C.. So. Wash Shed 35c Z661 1P 412 (1)RECEPTACLES . �., • 15 So. Wash Shed 37c 1 .. . 39c 100613P 19)P8 MAIN BREAKER 1-_'- 41c 1 • :• ✓ ... ' • .2.'"4''''';(*. 'Cr ` e' u. . " �. : :. -' -.r . ^Inspection 2a 20611P 412 j5) RECEPTACLES 7b ., •9.0y•.. .� ��IO 101 p 4b 20.611P 012 ({z�RR�J ACLED ''•� Inspection Shop 101 6c 20A/1P 412 LIGHTII4OCONTROLCLOCK 1.0 6a 2130/ 1P 412 Fuel Management 4S _ . 106 20A1P 412 SUMP PUMP CONTROL . • 20 ( BAY 7. 16 12c 154J1P 412 Fire Valve Pit Sump Pump 1/3', . 72 14a 20612P (21012 HOTWATBiFEAT131 14.6 ' • ,_ Restioom. Insp Shop 166 1 145 .;.. 18c - - SPACE .. , 20a 2Q6/ 1P 412 (S)RCCFWPG.ES 4S Roof - AHU- 2,3,EF -103 22b 2361P 412 SPARE ., 24c 15NIP 412 EI -107 DN. FAN iT40 • . . . 3.5 Roof. Col C -13 (Rm 103) 2Sa 4CW2P - SFMRE - . 2Eb I - . 30c BIN 1P 412 MEF101 D4-PUSTFiMORECEPT 145 Roof. Col B -10 32a 206/1P 412 SHED LTG, HOTWTRFOR 13.0 • . No. Wash Shed 34b MA/1P 412 TAFtECEPTS,LTGS 5.0 No. Wash Shed 36c 20A/1P 412 J11RE:EPTACIEE 1,5 No. Wash Shed s , , . fi : ... _ . CIRCUIT FOR REPLACED FAN AND CONTROLS. 78.0 47.0 48.71 TOTAL A PS RECE1. CITY OF TUKWI?A MAR 242008 PERMIT CENTER No. REVISION BY APP' D DATE DESIGNED: PROJECT NANA°. cams VI s/(7/3 CHEcXO - 1 Q McFARLAND IIV��� L I/ RECOMMENDED: D CRIPPEN K. MADDEN APPROVED: B. ISI.ER ms NO 432692/432721 .ac: CONTRACT NO: CO0130007 SCALE: NONE ONE INCH AT FULL SIZE • ( 1 IF NOT ONE INCH. SCALE ACCORDINGLY SRE LOCATOR NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT PANEL SCHEDULES DATE MAY 2007 DRAWING No- 2 E6.02 SHEET NO: IF 51 53 PANEL S BLDG FUEL /WASH TYPE Sq. 6. N000 (OBM 44244) SURFACE OR FLUSH SUR FACE MAIN BKR. 125A RATING 125A. 208Y/12DV. 3PH, 4W REF. DWGS. REVISION(s) As Built ENGINEER JS PELMAN (206 - 263 -3713) ELECTRICAL PANEL SCHEDULE ELECTRICAL PANEL SCHEDULE BASE SOUTH DATE Aug -04 PANEL T BLDG FUEL /WASH BASE SOUTH DATE LOCATION SE CORNER, Col. 8 -3 TYPE Sq. D, N H 1 B (HCN3263 -2MN) LOCATION SE CORNER. Cot. B -3 FEEDERS (4) 82, (I) 83G, 1 -1 /2`C SURFACE OR FLUSH SURFACE FEEDERS (4) 8300 Cu, 82(0 G. 2 -112 "C FROM Panel R, Circuits 1,3,5 via 45kVA XFM MAIN BKR. 225A FROM MAIN DIS 1 RIBU 1 ION PANEL SHORTCKT.RTG..)sym 1DkA RATING 225A,277Y/4BOV,3PH.4W SHORT CKT. RT(> Isym 25kA REVISED CKT. DATE REVISED JOB NO Jul 04(CMS) CIRCUIT FRAMES & AMPS WIRE SIZE DESCRIPTION HP PER S LOCATION a I b 1 c in 15A/ 1P 812 E>4TLIGHTS 1.0 - !r%1'-tka CCl_11 312 20A/ 1P 112 RINSEARO-I.DOCK DETECTOR (E/ ;} ;,_ • 1.0 .s_„.,ti 5c 20A/ 1P f 12 RINSE ARCH, DOCK DETECTCA (W) • ,,; e , ' -+4 2.0 7a 211 4/ 1P 112 PRESSURE WASHER 11.0 . Sb 2041 1P 812 QL WATER STATOR -.-'19:* 110 20A/ 1P 112 JIB CRANE HOST 1 /2"-_. :_. 9.8 13a 15A11P 812 SPARE - X111.0 r`�-- 15b 154 / 1P 812 SPARE ,.t `` _ry SPARE 17o 15A/ 1P 812 SPARE 17c 1 - 19a 151 IP A 812 SPARE 1 21b 15A1 1P 812 SPARE E. Ri 21b 23c 16A1 1P - SPARE 25a 15A/ 2' (2)112 DIESEL MIDDLE 11.0,. ^"fit -• : 27b I I 11,0 29c 15A1 1P 112 SPARE SPARE 81a 20A/ 1P 812 FUEL MCMTCR CCNTRO. 2,0 _.•%'''..• - ,T Ta.ii 38b 15A/ 1P 112 WASHER CCNTRCL 31a 910' - �;5`• .. (XL 6.10 85c 15A! 1P 812 F3-8DC I1*! CRC PUMP -. _.4,• =1•'' 1.0 BOILER RM108 37a 20A/ 1P 4112 CCNTROL PANEL 10.0 '.. ' ` 36c 89b 20A1 1P 4112 RRE SYSTEM COMPRESSCR 160 • 41c 20A/ 1P 112 Rvi5UP5 ,pp • - --# : 1 )'. 'r 9.0, • sue'.• :R " "+.;.. -.:: .i �. .. •. . ,-44- - ... ...i •- s x•.: > 2a I EF-10 5.5 11,0 ; 4b 20A! 3P 13)112 FP-1 DIESEL PUMP (1711 . - , 11 .'l.. z,`, 11.0 6c I ....L LO 11.0 8a I 4b • y riy s (31 It 12 DOOR 104 lOb 20Ar 31' (3)112 FP-2 DIESEL PUAP (CFI) 60 11.0 = ::'. 12c 1 1.6 8a I 14a 15A! 1P 812 SPARE 1012 • ' .a 431 012 DOCK 102 16b 15A! 1P 812 SPARE 12c .,, '- 18c 15A! 1P 812 SPARE . _ .'' - 20a 15A/ 2P (2) f 12 1133 ANTI-FREEZE PUMP TRANSFER 16b 15A/ SP - SPARE 2212 1 18c 4.0 ..:n.., 24c 20A/ IP /12 RECEPTACLES I _ ;:p„ 5.0 TOCL/.ENONEHTR 26a 20A1 1P If 12 RE(EPTACIES 13,0 .. TCXxS 28b 20A/ 1P 812 RECEPTACLES 13.0--.`' - " TOOLS 30c 20A/ 1P 112 RECEFTNO-ES !'..: ;vim: 13.0 TOOLS 32a 20A/ 2P 141 12 GAS PUMP (CFI) 13.0 • .' .:J; f, 20A/ 1P 34b I 6.5 ., 18.0 . 36e 16A/ 1P 112 FP-11 GBJ RJB Hi TRANSF PUMP ,: .--.:21.-. 6.0 38a 15A/ 1P 112 RJEUNG WARNING UGH TS 5.0 . , ;I.' s:. . -.4. 4012 70A/ 2P 38a SPARE a 11.0 .i•e 42c I 20A/ 3P (31112 EF-11 5.5 • ,, A A 70.01 100.0) 71.8 TOTAL AMPS REMOVE EXISTTNG BRANCH CIRCUITS. NE REF. DWGS. REVISION(s) As Built ENGINEER JS PELMAN (206 - 283-0713) REVISED CKT. DATE REVISED JOB NO. Aug-04 Jul 04(CMS) aRCUIT FRAMES & AMPS WIRE SIZE DESCRIPTION HP AMPERES LOCATION a b 0 1a I 1,6 3b 15A! 3P (3) 4 12 DO(>F1103 1.8 5c I 1.6 7a I 1.6 912 15A/ 3P (3)112 DOCK 101 1.6 11c I 1.6 13a 1 - 15b 154! 31' - SPARE 17c 1 - 19a 1 21b 80A/ 31' 131 14 PANEL P3 SUB FEED 23c I 25a I 27b 80A/ 3P SPARE 29c I 31a 204/ 1P 412 SPARE 3$b 15A/ IP 812 SPARE 36c 20A/ 1P 112 SPARE 37a 1 11.0 3912 20A! 3P 13) 4 12 EF-10 5.5 11,0 41c I 11.0 2a 1 1.6 4b 15A/ 33 (31 It 12 DOOR 104 1.6 60 1 1.6 8a I 1.6 1012 15A/ 8P 431 012 DOCK 102 1.6 12c I 1.6 14a 1 - 16b 15A/ SP - SPARE 18c 1 - 20a I 2212 25A/ 3P MI /10 SPARE 24c I 26a 20A/ 1P 812 JJGHTS! TIME CLOCK 72 2812 20A/ 1P 812 UGHTS 6.5 300 20A/ 1P 112 UG-)TS 6.5 32a I 34b 6041 31' PANS_ 'U' SUBS 36c 1 38a I 11.0 4012 20A/ 3P (31112 EF-11 5.5 11.0 420 1 11.o 91 TOTAL AMPS ADD NEW CIRCUIT FOR TRANSFORMER T3 AND PANEL P3. REUSE EXISTING BRANCH CURCUIT FOR REPLACEMENT FAN. PANEL P3 BLDG FUEL /WASH TYPE Sq. D. NH1 B (HCN2754 -2MN) SURFACE OR FLUSH SURFACE MAIN BKR. 1 DOA RATING 225A. 208Y/120V. 3PH. 4W REF. DWGS. REVISION(s) ENGINEER ELECTRICAL PANEL SCHEDULE BASESB DATE LOCATION ELECTRICAL ROOkI FEEDERS (4) 84, (1) 88 G FROM Panel "T" VIA 73, 30 KVA SHORT CKT.RTG..Isym 1OkA REVISED CKT. DATE REVISED JOB NO. Mar -07 RCUIT 1a 3b 5c 7a 912 1lc 13a 1512 17c 19a 21b 23c 25a 27b 290 FRAMES & AMPS 20N IP 2044/1P 200/1P 20A/1P 204/11' 20,11/1P 20A( 1P 20A/ 1P WIRE SIZE 12 12 12 DESCRIPTION EF4. EF6 EFS, Er-8 EF-1, EF2 SPARE SPARE SPARE SPARE SPARE SPA/ SPACE SPICE SPACE SPACE SPACE SPACE HP 1211/4 (2)1/4 (2)1/4 PERES a l b l c 14.4 14.4 _LOCATION • 14.4 ROOF ROOF ROOF , 4b 15N 1P 12 6c 15JV 1P 8a 15N1P 1012 15J41P 12c 15N IP 15N 1P EF7.EF8. RECUT. RECEPTACLE SPARE 1/401/25 7.0 . RCCF 1.5 ROOF SPARE ' SPARE SPARE SPARE SPACE SPACE SPACE SPACE SPACE SPACE SPACE c AQ\ ot441‘' NEW PANEL "P3" SCALE: NTS 21.4 15.9 14.4 TOTAL AMPS RECE �..' CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER A A A No. REVISION BY APP'D DATE DESIGNED: L McFAR PROJECT K. MADDEN APPROVED: LE 4u- B. ISLER IBIS NO: 432692/432721 C. REYNOLDS .0ac REQUEST: NONE ONE INCH AT FULL SIZE I- IF NOT ONE INCH, SCALE ACCORDINGLY RECOMMENDED: Lomas 6 /13 /0e D. CRIPPEN CONTRACT NO: COO 130007 SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT PANEL SCHEDULES DATE MAY 2007 DRAINING NO: 2 E6.03 SHEET NO: OF 52 53 L1 L2 L3 1 1 1 480-24V 150VA OL NOTES GRINDER • -o-i do- - HOOD SW. -r r _ 1 LIGHT SW, L EF -106 (EXHAUST) FAN CONTROL CIRCUIT SCHEMATIC SCALE: NTS RUN SIGNAL FOR EF -9 AND EF -10. USE CONTACT IN EXHAUST FAN CONTROL PANEL INSTEAD OF THERMOSTAT. CONTACT "C" LOCATED IN EXHAUST FAN CONTROL PANEL. T HOOD LIGHT) •O• 8 480 -120V OFF HAND AUTO ADJ. SET SET AT 85 °F . Q • . 4 ❑ 0 0 X EF -9, EF -10 AND EF -109. 480V EXHAUST FAN THERMOSTAT CONTROL SCHEMATIC SCALE: NTS ❑L L N I I I I I I I I EF ❑L .© OFF HAND AUTO ADJ. SET AT 85T 0 120V EXHAUST FAN THERMOSTAT CONTROL SCHEMATIC SCALE: NTS 0 REVIEWED FOR CODE. CO Op NEC {�FPA APR - 3 2000 Oty Oi "Wit ;•N • ❑L EF -1 THROUGH EF-6 120V FUEL LANE EXHAUST FAN CONTROL SCHEMATIC SCALE: NTS RECE. CITY OF TUKWILA MAR 2 4 2008 PERMIT CENTER REVISION BY APP'D DATE I COVES 6 /13 /Q8 DESIGNED: L McFARLAND D. LE CHECK C. R LDS RECOMMENDED: D CRIPPEN �' PROJECT MANAGER: K. MADDEN APPROVED: SCALE: NONE B. ISLER J�•� IBIS NO: 432692/432721 CONTRACT NO: C00130007 ONE INCH AT FULL SIZE 1 IF NOT ONE INCH, SCALE ACCORDINGLY SITE LOCATION NO: King County Department of Transportation METRO TRANSIT DIVISION ATLANTIC BASE AND SOUTH BASE EXHAUST FAN REPLACEMENT EXHAUST FAN CONTROL AND THERMOSTAT CONTROL SCHEMATIC DATE MAY 2007 DRAWING NO: 2 E6.04 SHEET NO: OF 53 53