HomeMy WebLinkAboutPermit EL08-0324 - WESTFIELD SOUTHCENTER MALL - WET SEALWET SEAL 2446 SOUTHCENTER MALL ELO8-324 Cityef Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2446 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -324 Issue Date: 05/22/2008 Permit Expires On: 11/18/2008 Tenant: Name: WET SEAL Address: 2446 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: REBECCA MILSTER Phone: 800 -489 -2233 Address: 1950 CRAIG RD STE 300 , ST LOULS MO Contractor: Name: STATIC ELECTRIC INC Phone: 253 468 -3296 Address: PO BOX 972 , GRAHAM WA Contractor License No: STATIEI951C8 Expiration Date: 02/25/2009 DESCRIPTION OF WORK: NEW LIGHTING AND ELECTRICAL PANELS Value of Electrical: $40,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: J Fees Collected: National Electrical Code Edition: Date: $980.50 2005 - -0 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the • erformance of wor I am a orized to sign and obtain this electrical permit. Signatur Print Name: L J�t>► r { ill nSo 1 Date: 5-2-z-0 5' -Zz` O5' This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -324 Printed: 05-22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2446 SOUTHCENTER MALL TUKW Suite No: Tenant: WET SEAL Permit Number: EL08 -324 Status: ISSUED Applied Date: 03/27/2008 Issue Date: 05/22/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature. Print Name: a t'1 el !Se, Date: S' 22 doc: Cond -Elec EL08 -324 Printed: 05-22 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Electrical Permit No. ELD9 � Project No. CY11,- (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION �`1 c King Co Assessor's Tax No.: bib 420 —Oo it) Site Add e s � ' t s.A Ce eAr -\ Ti1 c,, 1e, toil. Suite Number: Floor: 1 Si- Tenant Name: We\- SeQ.1ll Property Owners Name: W es CO\re D y o`A'lOVA �n C • Tu iut State New Tenant: . Yes ❑ ..No Mailing Address: ?lq (p StnA44, 01,14e,v mut,u City 118188 Zip CONTACT PERSON -Who do we contact when your permit is ready to be issued Name: ' - ecc nil del-- 1150 Grad 3 mil. S }e. 300 r r i S €at- cv.c..>3m Mailing Address: E -Mail Address: Day Telephone: 8o 0-- ((89 -9933 5�. LokAt ln3P4(o City State Zip Fax Number: 314- 41 S -2300 ELECTRICAL CONTRACTOR INFORMATION Company Name: 1-13D Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 40 t Q l7 0 Scope of Work (please provide detailed information): 11P L.J l tQ ii1`��I pafr\¢.lS aAAA 1a&A Will service be altered? ❑ Yes rz No Adding more than 50 amps? ❑ Yes ® No Type of Use: Type of wo-k: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Lcw Voltage ❑ Generator ❑ Fire Alarm Property Served by: ❑ Puget Sound Energy ❑ Seattle City Light 11 \.Appbcations'Portns•Apphcanons On 1 Ine'i1 -2007 • P ectncal Permit Application doe bh `g Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, fumace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, fumace thermostat) MULTI - FAMILY AND Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ca PERMIT APPLICATION NOTES - 1 Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WAS}IINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: \9 C. CA mt c£> Mailing Address: 1 & Ccon (�A. / 5kt- 30 Day Telephone: City Date: 3- —fl V BOB- 4- '1q 33 I(n� ce ;1(1(.0 State Zip Date Application Accepted: .7_05 Date Application Expires: l d 7 _0 tJ Staff Initials: II \Applgntionstrnr na- Apphcannm (hr I. mc,t -21)01 • Plecnical Pc, nw Application dor hh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http : / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -324 Address: 2446 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/27/2008 Applicant: WET SEAL Issue Date: Receipt No.: R08 -01777 Payment Amount: $796.00 Initials: WER Payment Date: 05/22/2008 10:54 AM User ID: 1655 Balance: $0.00 Payee: STATIC ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3714 796.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 796.00 Total: $796.00 2761 05/22 9711 TOTAL 1568.00 doc: Receiot -06 Printed: 05-22 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -324 Address: 2446 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 03/27/2008 Applicant: WET SEAL Issue Date: Receipt No.: R08 -00937 Initials: WER User ID: 1655 Payment Amount: $184.50 Payment Date: 03/27/2008 01:30 PM Balance: $738.00 Payee: ARCVISION INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 16277 184.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 184.50 Total: $184.50 doc: Receiot -06 Printed: 03 -27 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CLOY - 32 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 8- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: � f ',M ■ (/i/TJ V Type of Inspection: � oo 3 f 2 t Address: -''V friktiu Date Called: �� Special Instructions: 1 Date Wanted: f i� tr a:m: Requester: Phone No: lei Approved per applicable codes. D Corrections required prior to approval. COMMENTS: out, I NJ c6ItA rJc4, • Inspector: Date: . J 40 ■8 ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit 6Gor- 3.41 PERMIT NO. (206)431 -3670 Project: CT 5Ckt_ Type of Inspection: 7003 Address: iii( iii(V9 tliPigi Date Called: of cA4 i-lic 64- 5 Special Instructions: Date Wanted: 1/14 Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: — (11I0 P. ■14 ujt'Jh 401 .r...611-iNki - Sum ., tAItipJ 17-" of cA4 i-lic 64- 5 - 5trigov flik 'P ®( tN 1101 tt� az6 - 5tPf otr rIC Aov QiSCt74T Inspector: Date: 01116,10 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: 1 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit 6LIA-32'I PERMIT NO. Project: Oer. SfV Type of Inspection: 70C42 - twth G. e.0 . Cakbacrt DJ T Address: iti 410 timici Date Called: 76 CoLj 17t1vi-rfzi LoCgAhrr 04%) Sec. rta9e Special Instructions: K RI R T 203 ,, 4-t - Date Wanted: 1 bit, : 1 - • Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: - twth G. e.0 . Cakbacrt DJ T giLD4 • SIM, 4 t $SSt6t.6 - (Soni D Cam, D Wes( ADD ii01 76 CoLj 17t1vi-rfzi LoCgAhrr 04%) Sec. rta9e - 6.4.C- #4 g ttot`'i K RI R T 203 ,, 4-t - - 5l -fo2T 5(c.o ( 1f rLex Rot, x r-- & go 4 Fi...e Inspector: -1/11 466114k1( Date: v..r [ t 610'' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1.00, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Oodf- 31,1 PERMIT NO. (206)431 -3670 Project: �� �f�� G Type of Inspection: Address: Date Called: Special Instructions: 1 Date Wanted: 1 17 Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: • Inspector: Date: 07/11 /og El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: r ewrgmatgogsdrisil•209in st INSPECTION RECORD Retain a copy with permit 311 INSPECTION INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: up...... $1, Type of Inspection: 1003 5615Pt ICI C "111'-5 AA Address: Pi tI ( Date Called: Sox -- gEri 3 D(A cD 5lq E.11.1--- Special Instructions: Date Wanted: it I ) p.m. Requester: AAi Skins tib w. ,r $ - nee otoleri, u , u4t.6 A4t/ C X46 Phone No: Approved per applicable codes. 16 Corrections required prior to approval. COMMENTS: 5615Pt ICI C "111'-5 AA 5gPPoQr t\L c'segt5 - 5.0.Pb2i tit wkno4 i2 " ar Sox -- gEri 3 D(A cD 5lq E.11.1--- Fkot4 CE11.tJL1 - - AO /Jar / tJ Re CtamAl p ?b 5Pie -iikak PIPC - SuPPok'T- AAi Skins tib w. ,r $ - nee otoleri, u , u4t.6 A4t/ C X46 Q-Ext4S islarix, 'u?P0(1 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: e INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Egg -321 PERMIT NO. (206)431 -3670 ti Project: Or 5 fitt.- R.) Type of Inspection: Gj Act_ Cirs 4 (Jake - RC_ Air rendr- c,A h) JJ -P Address: UUrrL( pI ` Date Called: - *(-5 /40T- rigkvt UP tot/ J ISO& f.544 -(AJc. Special Instructions: Date Wanted: 4-I a.m. (----- '- Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: — 0 d'r 1, (Trj ,J6T 14 vrekuieb A-- Gj Act_ Cirs 4 (Jake - RC_ Air rendr- c,A h) JJ -P To , SF 5t u.A cp 1. )%f- tni a "dF fa - *(-5 /40T- rigkvt UP tot/ J ISO& f.544 -(AJc. Inspector: 66Vdbc, 'Date: b� fri(o $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be k paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Etog -3Z1 Project: LJGT 51m.^- Type of Inspection: 1003 Address: 2 4 9 ( tit Date Called: Special Instructions: Date Wanted: 4'7 0 ).m• Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: L'0 �D�Q -d7 Liii S d- f.FQo•JT P4D-rt-t--9 Inspector: &Wc ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 04/2„.0/0)r Receipt No.: Date: gong ^' eo w 4xNtci' —•t �ti3r g,•�. r•a..z. ees.. e_ a .�. era: s..wr INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 13.Y-321.1 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 I0 Project: Cyr 5c Type of Inspection: 700, Address: 21 4 Date Called: r^ Special Instructions: Date Wanted: 17 a.m. C Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 124 Inspector: 4,1Altic (Date: N 06/1.7/0)? 06/1.7/0)? El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: aeahaal • .••• .a_,... �•�cra.�r..�•� .. - . Y ....a.ef r._b JR& INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �e r . .ce., /._., Type of Inspection: 7f 3 Address: 4 ?Ink, .. 7c1fr fl4 114./ Date Called: Special Instructions: Date Wanted: 6:// / ( awry m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. OMMENTS:/�, C l4 - a/.S? /1 "- N/41-is //,71444 c/6 S h /EGGS - .. 4f-6-S 11i(Y-4 Inspeirsi ....v.:44.46,xecy/ Date: /6 /J1( $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: r is ;Inter!, 2006 Washington State Nonresidential Energy Code Compliance Form ing Sumr`marytt; 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address SOUTHCENTER MALL - O ETSEAL SPACE F-13) Date 3/20/2008 1056 SOUTHCENTER For Building Department Use SEATTLE, WA 98188 Applicant Name: LE COPY Q_ Applicant Address: "'P -� y.. Applicant Phone: r' Project Description 11 New Building ❑ Addition ❑ Alteration [ ]Plans Included ,^+lf r"' Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option O Prescriptive C Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area RETAIL 1.50 3977.0 5965.5 RETAIL DISPLAY FOOTNOTE #10 1.50 3977.0 5965.5 L - WALL WASHER :a�Vl gg? 14 55.0 770.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 11931.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed A - DOWN LIGHT p 30 45.0 1350.0 H - HIGH HAY E� /°� 8 175.0 1400.0 L - WALL WASHER :a�Vl gg? 14 55.0 770.0 s^ LN1 M TRACK HEAD /0 90 75.0 6750.0 Q - CYLINDER q��� 3 45.0 135.0 R - STRIP J �u 11 62.0 682.0 0 Z - LIGHT FAN COMBO ► 2 60.0 120.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 11207. 0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if inc.uded). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. £LOS3214 RECEIVE) MAR 272008 PERMIT CENTER - -s a tf. 1, -:a„ i�' :• {,r Interior 2006 Washington State Nonresidential Energy Code Compliance Form t n9 ummary l(ba 2008 Washington State Nonresidential Energy Code Compliance Forms ri Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers (D Other Qualification Checklist Chklist Note: If occupancy type is "Other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) o Li Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector ) p ) or louvers, c) 5 -60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, $ hospitals, institutions, museums, banks, churches Penitentiary and other Group 1 -3 Occupancies 1.0 1.0 Convention center 1.2 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments', restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail', retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia5, assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies . ." 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference /exhibition hal15.4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 ootnotes for t able 15- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For confe-ence rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display w ndow illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or al least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the rack.s. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. PER IT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: ELO8 -324 DATE: 04 -22 -08 PROJECT NAME: WET SEAL SITE ADDRESS: 2446 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued DEPARTMENTS: BuiTdfhg Dtilslon Pubic Works 6 Fire Prevention Structural n n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -24 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-22-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Deparments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documeits/routing slip.doc 2 -28-02 PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -324 DATE: 03 -27 -08 PROJECT NAME: WET SEAL SITE ADDRESS: 2446 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTM NTS: id Bul ing Divi ion Pub is Works l l Fire Prevention Structural n Planning Division ❑ Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -01-08 Not Applicable n Permit Center Use Only INCOMPLETE LETTER MAILED: Departments detemiined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS RO TING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 04 -29 -08 Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1/(2406' 06' Plan Check/Permit Number: L t - 3,2., ❑ Response to Incomplete Letter # ❑ Response to Correcti9n Letter # la" Revision # 1 r Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: We. f Se- d_ Project Address: oZ4-96, So // Contact Person: Re h e /{.(,' /s k- Phone Number: Ud - 1- 3 3 Summary of Revision: 1 CDRi. i 5/ 0�.5 L7-'S re , L t°t�n� [ er� m 1 --7--14 RECEIVED CITY OF TuKw111i • 22 awe PERMIT Cal k Sheet Number(s): /Erb t /O/ £(o Z "Cloud" or highlight all areas of revision influding dare of revision -PC)1—if Received at the City of Tukwila Permit Center by: � �Entered in Permits Plus on 1 2-O lapplicationslfonns- applications on linelrevision submittal Created: 8-13 -2004 D-', I. Look Up a Contractor, Electrii or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License STATIEI951C8 Licensee Name STATIC ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602455807 Ind. Ins. Account Id PRESIDENT Business Type CORPORATION Address 1 26026 116TH AVE SE Address 2 City KENT County KING State WA Zip 98030 Phone 2534683296 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 2/25 /2005 Expiration Date 2/25 /2009 Suspend Date Separation Date Parent Company Previous License Next License Associated License JOHNSS *973PH Electrical Administrator Information License JOHNSS *973PH Name JOHNSON, SHANE Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date JOHNSON, SHANE E AGENT 02/28/2005 JOHNSON, SHANE E PRESIDENT 02/28/2005 • Bond Information i i Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= STATIEI951 C8 05/22/2008 LP -24 (AI IIP.IIII�. I %:lllffll:IIII tIl IIIIIIIIIIIIII , ' ". /e•"''M •'fl r.. 1 sir~ --� — _ •;. a'? e shell be ma!1€? to thn ^t' work without prior approval jf Tukwila Building Division NOTE: Revisions will require a new pan submittal ' and may include additional plan review fees MP- 7,9,11 SOUND SYSTEM LEGEND SP CEILING SPEAKER. FURNISHED AND INSTALLED BY SOUND SYSTEM PROVIDER. I . », , » »» €. i 3 � E5 S I i 3 AUDIO EQUIPMENT LOCATION. FURNISHED AND INSTALLED BY SOUND SYSTEM PROVIDER. E ..............J 3 1 CV I u ,..,,... ..,.... ......... 51 £ ....... k r Na . a , .ry.. E f. £ ..... .......... r WALL MOUNTED VOLUME CONTROL. FURNISHED AND INSTALLED BY SOUND SYSTEM PROVIDER. El ALL SPEAKER CABLE TO BE WHITE 18 AWG, 2 CONDUCTOR, PLENUM RATED. ALL AUDIO SIGNAL WIRE TO BE 22 AWG, 2 CONDUCTOR W /SHIELD. GENERAL SPEAKER NOTES 1. G.0 /E.0 RESPONSIBLE FOR PROVIDING AND INSTALLING ELECTRICAL OUTLETS AND CONDUIT. 2. REFER TO EQUIPMENT OWNER'S AND INSTALLATION FOR ADDITIONAL DETAILS. 3. ALL HANGING HARDWARE TO BE WHITE AND INCONSPICUOUS. 4. ALL EXPOSED CABLE AND /OR CONNECTORS TO BE WHITE AND INCONSPICUOUS. USE ALL MEANS NECESSARY TO ENSURE NO CABLES ARE VISIBLE. TELEPHONE RECEPTACLE MTD. BELOW COUNTER © 18” A.F.F. QUAD RECEPTACLES MOUNTED BELOW COUNTER a. 18" A.F.F. 1 OF 4 GROMMETS SEE DTL. 2/A505 /9 „ /9” UNE OF REAR CASH WRAP COUNTERS & / CABINET ® 36" A.F.F. 9," f REAR CASH /WRAP POWER SCALEt NONE 11„44:/zTIT.g,z ,0IIIsIII IIIff, GENERAL NOTES 1. MOUNT ELECTRICAL PANELS ON PLYWOOD BACKER BOARD(S). 2. THE T.E.C. IS REQUIRED TO MAKE A FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE AND IS RESPONSIBLE FOR MAKING ALL MODIFICATIONS REQUIRED TO INSURE THAT THE TOTAL LOAD DOES NOT EXCEED THE ELECTRICAL SERVICE. ANY UPGRADES ARE AT G.C. EXPENSE. - CABLE TYPES AC AND NMC ARE NOT ACCEPTABLE. - ALL WIRE SHALL BE COPPER. - GROUND SEPARATELY DERIVE SERVICE. INCLUDE BUILDING STEEL IN GROUND IF POSSIBLE. - CIRCUIT BREAKERS SHALL BE BOLT -TYPE. - ANY FLEXIBLE CONDUIT SHALL NOT EXCEED 5' -0" IN LENGTH. - NEW ELECTRICAL WIRING MUST BE KEPT AS "INTERIOR" WIRING AND MUST BE COORRDINATED WITH MALL MANAGEMENT. - ALL ILLUMINATED SIGNS MUST BE CONTROLLED BY A 7 -DAY TIME CLOCK. 3. APPROVAL OF TENANT'S CONSTRUCTION DOCUMENTS AND SPECIFICATIONS BY THE LANDLORD DOES NOT RELEASE THE TENANT OR THE TENANT'S CONTRACTOR FROM COMPLYING WITH THE LEASE AGREEMENT AND ALL APPLICABLE BUILDING CODES AND GOVERNING REGULATIONS. 4. NOTHING IS PERMITTED TO BE ATTACHED TO, OR SUSPENDED FROM, OR PENETRATE THE ROOF DECK ABOVE. G.C. SHALL BE REQUIRED TO FRAME, BRACE AND /OR SUSPEND, AS NEEDED. TO /FROM THE TOP GHORD OF JOISTS OR STRUCTURAL STEEL WHICH EXIST ABOVE YOUR RESPECTIVE TENANT SPACE. 5. COORDINATE ALL FLOOR CUTS WITH ON SITE FACIUTY MANAGER. IT IS THE G.C. RESPONSIBILITY TO TAKE ANY PRECAUTIONS NECESSARY TO INSURE THAT ANY UNDERGROUND UTILITIES, ETC. ARE NOT DAMAGED DURING FLOOR CUT OUT. ANY DAMAGE SHALL BE REPAIRED AT G.C. EXPENSE. 6. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY ALL ELECTRICAL CONDITIONS. 7. NO UTILITIES IN THE DEMISE PARTITIONS. 8. COORDINATE ALL FLOOR CUTS WITH ON SITE PERSONNEL. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT E.C. SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE EQUIPMENT SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT'S TELEPHONE EQUIPMENT IS NOT PERMITTED IN LANDLORD'S TELEPHONE EQUIPMENT ROOM. TENANT E.C. SHALL PROVIDE PLENUM RATED WIRE FROM TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. �II1lIIIIIIIIiIIII� POWER PLAN SCALE ve - ro LP -10 LP -1 . ,JE.t- ;RATE PERMIT REQUIRED FOR: wiMechanical Electrical VFW:n*41g Gs Piping CAN, Tuileasla REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC 1 APR 2 5 X00 ity Of Tukwila BUILDING DIVISION _ FILE COPY' Permit No Piar review approval is subject to errors and omission' Approval of construction documents does not alt o& the violation of any adopted code or ordinance. Rai of approved F id Copy and a, edde By [date: S —2-2-- p City of Tuivirila POWER KEYED NOTES C.: J9! rhtht", 593f wreak S ,gyp n ,/ tii,Wietr 0 PROVIDE ROUGH -IN ABOVE CEILING AND FINAL CONNECTION TO ILLUMINATED SIGN. PROVIDE DISCONNECT SWITCH AS REQUIRED BY N.E.C. 600. ® THE CIRCUITS USED TO POWER THE ELECTRONIC CASH REGISTERS SHALL NOT BE USED FOR ANY OTHER PURPOSE. CIRCUITS SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER, NEUTRAL, AND INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG SHALL BE RUN TO THE CIRCUIT BREAKER PANELBOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL ISOLATED FROM NEUTRAL. DO NOT USE CONDUIT FOR GROUNDING AS THIS MAY NOT BE CONTINUOUS. CASH REGISTER CIRCUIT SHALL BE RUN IN SEPARATE CONDUIT. PROVIDE A SQUARE 'D' #SDSA1175 SURGE ARRESTER FOR P.O.S. CIRCUIT. ® PROVIDE (5) CONDUITS, (1 DEDICATED P.O.S CIRCUIT, (1) FOR GENERAL POWER CIRCUIT, (1) CAT 5 CABLE FOR INTERNET, (1) FOR PHONE UNES (1) FOR FUTURE USE. ROUTE CONDUITS AS SHOWN ON PLAN DOWN WALL OR COLUMN AND BY CORE DRIWNG FLOOR. PATCH FLOOR AS REQUIRED. E.C. SHALL FIELD VERIFY EXACT CONFIGURATION AND LOCATIONS WITH G.C. 4 E.C. SHALL PROVIDE AND INSTALL P.O.S. RECEPTACLE HUBBELL 4 -PLEX #IG420 AND GENERAL USE DUPLEX RECEPTACLE FOR MISC. POWER. J -BOXES FOR RECEPTACLES SHALL BE SURFACE MOUNTED ON INSIDE OF THE CASHWRAP AT 18" A.F.F. 5® E.C. SHALL PROVIDE AND INSTALL QUAD PLEX RECEPTACLE AND TELEPHONE OUTLET MOUNTED AT 18" A.F.F. FIELD VERIFY EXACT CONFIGURATIONS AND LOCATIONS WITH FIXTURE INSTALLER AND G.C. • E.C. SHALL PROVIDE AND INSTALL QUAD RECEPTACLE MOUNTED AT 18" A.F.F. AT BACKWRAP • 20A RATED QUAD DEDICATED RECEPTACLE WITH ISOLATED GROUND ABO CEILING FOR SENSORMATIC SYSTEM. THE AC SOURCE MUST BE A 3 -WIRE 24 HOUR UNSWITCHED OUTLET WITH LESS THAN 0.5 VAC BETWEEN NEUTRAL AND GROUND. PROVIDE "LOCK -ON" DEVICE ON BREAKER AT PANEL COORDINATE EXACT LOCATION AND REQUIREMENTS WITH G.C. AND SENSORMATIC. THIS IS NOT A TOWER SYSTEM. 11 E.C. SHALL PROVIDE AND INSTALL QUAD RECEPTACLE MOUNTED AT 66" A.F.F. FOR AMPLIFIER AND DVD SYSTEM. FIELD VERIFY EXACT LOCATION WITH G.C. 12 E.C. SHALL PROVIDE (2) COMPLETE DOOR BELL SYSTEMS AS FOLLOWS: SYSTEM 1: 24V. PUSHBUTTON, EDWARDS 1786, MTD. AT 48" A.F.F. AT REAR EXIT DOOR CONNECTED TO 24V. TRANSFORMER EDWARDS _#592, MOUNTED 10'-O A.F.F. A.F.F. IN STOCKROOM AS# SHOWN. TRANSFORM TO BE BE LOCATED IMMEDIATE Y ADJACENT DVTO DTRANSFORMER RNT STOCKROOM; BELL UNIT TO SECOND BELL UNIT ABOVE SUSPENDED SOFFIT (12' -6 ") AT CASHWRAP. SYSTEM 2z 24V. PUSHBUTTON, EDWARDS 1786, MOUNTED IN FRONT CASH WRAP, CONNECTED TO 24V. TRANSFORMER, EDWARDS #592 MOUNTED 10'- 0 "A.F.F. IN STOCKROOM AS SHOWN. TRANSFORMER TO BE CONNECTED TO (1 ) BUZZER UNIT, EDWARDS #15 -1G1, MOUNTED IMMEDIATELY ADJACEN T TO TRANSFORMER. NOTE: SOUND OF BELL UNITS FOR SYSTEM 1 ARE TO BE DISTINCT FROM SOUND OF BELL UNIT FOR SYSTEM 2. 13 GFI DUPLEX FLUSH MOUNTED 42" A.F.F. 14 ODUPLEX RECEPTACLE, PHONE AND FAX OUTLETS TO BE MOUNTED AT 38" A.F.F. FIELD VERIFY EXACT LOCATIONS. 15 1" C. TO T.T.B. W/ CAT 5 CABLE FOR INTERNET. E.C. SHALL LEAVE 3' EXCESS CABLE AT T.T.B. & CASH WRAP. DUPLEX RECEPTACLE FLUSH MOUNTED IN CEILING PER N.E.C. 210 -62. DUPLEX RECEPTACLE FLUSH MOUNTED AT 15" A.F.F. SPEAKERS AND RECEIVER PROVIDED AND INSTALLED BY OTHERS. E.C. SHALL SUPPLY AND INSTALL J -BOX AND 3/4" CONDUIT WITH PULLSTRING AT RECEIVER LOCATION. CONDUIT SHALL RUN INSIDE WALL UP TO STRUCTURE AND STUB OUT. PLENUM RATED SPEAKER CABLE SHALL BE PULLED TO EACH SPEAKER LOCATION BY OTHERS. CABLING SHALL BE RUN TIGHT TO STRUCTURE AND PARALLEL AND PERPENDICULAR TO STRUCTURE. 18 19 LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FIRE ALARM SYSTEMS OR COMPONENTS. TENANT G.C. SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS AS REQUIRED BY THE LOCAL AUTHORITY HAVE JURISDICTION. TENANT G.C. SHALL CONTRACT WITH LANDLORD'S DESIGNED FIRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT'S G.C. EXPENSE. TENANT G.C. SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. A COPY OF FIRE ALARM DRAWINGS SHALL BE ISSUED TO THE LOCAL FIRE MARSHAL'S OFFICE. TENANT G.C. SHALL FURNISH AND INSTALL DUCT DETECTORS WITH REMOTE TEST SWITCH AND LED INDICATOR LIGHTS IN SUPPLY AND RETURN MAINS FOR EACH TENANT VAV UNIT AS REQUIRED BY CODE AND LOCAL AUTHORITY HAVING JURISDICTION. CLOCK TYPE RECESSED RECEPTACLE FOR LIGHT BOX MOUNTED ON CENTER OF BACKWRAP AT 8' -0" A.F.F. E.C. SHALL PROVIDE AND INSTALL 3/4" CONDUIT WITH PULLSTRING FROM FIRST P.O.S. CABINET TO PC FIXTURE IN THE STOCK ROOM. E.C. SHALL PROVIDE AND INSTALL A J -BOX WITH 6 PHONE OUTLETS AND A SEPERATE J -BOX WITH A SINGLE PHONE OUTLET. BOTH ARE TO BE MOUNTED 18" A.F.F. AT FIRST P.O.S. CABINET. QUADPLEX RECEPTACLE FLUSH MOUNTED AT 15" A.F.F. FIELD VERIFY EXACT LOCATION OF LANDLORD COMMUNICATION CABLE TRAY AND EXTEND PLENUM RATED PHONE CABLE AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTIUNG OF NEW ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX RECEPTACLE FOR POWER TO TELEPHONE EQUIPMENT. EC SHALL PROVIDE TELEPHONE SERVICE TO SPACE IF NOT ALREADY PROVIDED BY LANDLORD. NON-FUSED DISCONNECT SWITCH MOUNTED NEXT TO WATER HEATER FOR CONNECTION OF TANK TYPE WATER HEATER. RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. 210 -63 AND 210 -70c PANEL "LP ". REFER TO PANEL SCHEDULE. PANEL "MP ". REFER TO PANEL SCHEDULE. TRANSFORMER. REFER TO ONE-LINE DIAGRAM REV1S1ON N01tL LO8 32'1 RECEIVED APR 2 2 2008 PERMIT CENTER W »....» ...... .. .... ...... »...... I ..,(, I . », , » »» €. i 3 � E5 S I i 3 ..,»»,.. y' ... CC ..,...�......... 5� ' 0 s CN., d' Nr 3 1. 1. i I} 1 CO f., _ ..............J 3 1 CV I u ,..,,... ..,.... ......... 51 £ ....... k r Na . a , .ry.. E f. £ ..... .......... r -. • (.: „,,,..,.... .......,..y m.......m .,. .., ».'.,» 1 J 1 3 1 »- •r 5 ...... ,,,,,,, £ .'y ......... Imo_ » CCH Cl ,WY c C) W' a� m £ a€ -I r t 5 i{t £ s £££; s N M O o g m C 3 € II ., W f r J f i Fs � s 1 00 O N=W £ I Q E100 ) L: FIXTURE TYPE "A". TYPICAL AT DRESSING ROOM --"E "5' 0 0 A-74- 7/. ... FIXTURE TYPE "L". 'TYPICAL ps H iFIXTURE TYPE "M". TYPICAL PS PS • LP— 9 FIXTURE TYPE "Q". TYPICAL 1 FIXTURE TYPE "B". TYPICAL LP-23 EM EM EM LP-19 EM NL EM EM EM LP-13 LP-15 " REVIEWED f__ 17°PFPCP,°77-11NEZ" .......... PPR 2 5 MB atukwila BUILDIN D IOW 1 p.pffizmizwzmimr./E.,,,,7 .4; „/.,; w,-/zza-gzizezamy...77,0 gg3 LIGHTING PLAN SCALE 1/4' 11-0' A a b c d e 00000 LP-17 LP-21 LP-27 SALES LP-19 LP-9 LP-11 LP-13 LP-15 SALES SALES SALES SALES SALES HIGHBAY TRACK TRACK TRACK TRACK LJGHTING LIGHTING LIGHTING LIGHTING LIGHTING f g h • LP-17 LP-21 LP-27 SALES SALES CORRIDOR TRACK BACKWRAP STRIP UGHTING LIGHTING LIGHTING CONTRACTOR TO VERIFY EXACT CONFTGERATION REQUIRED WITH SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER 11-IAN 48" SWITCH BANK I SCALE NOPE CO COI CO 1 REVISION Mal_ RECEIVEr APR 2 2 2008 L08 3241 PERMIT CENTEF LIGHTING KEYED NOTE: 0 CUT 4'-O" TRACK TO 2'—O" LENGTH. r-,\ EMERGENCY LIGHT FIXTURES TO BE MOUNTED SAME HEIGHT \Iv AS TYPE 'A' LIGHTING. _1; 4ct• 4= 5 E101 LIGHT FIXTURE SCHEDULE LAMP SCHEDULE REF QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION NOTES VOLTS REC SUR PEN WAL Fl XT LAMP WATTS MANUFACTURER/ 13 Q A PRESCOLTTE LF6CFH132EB/ 6CFH1 6" COMPACT FLOURESCENT DOWNUGHT W/REFLECTOR : r Ir 1►! t t r r 6 "DOWNUGHT W /REFLECTOR 1 Y� 1 120 120 X r r . X Wr 0— N.L. VIA T/C �� 1 JYriYY� 1 42 �r 39 45 , r r * 44 SYLVANIA CF42DT/ E /IN /830 /ECO �►�+■- MCP39PAIRR3OLN U 830 FL ECO •B 16 0 AA INTENSE IMH6039E1100 IC600SF 8 NO BRKR SIZE B HUBBELL BL150H8PA2WH 16" HIGH -BAY 1,2,4 120 X WATTS DESCRIPTION CKT 1 150 175 MCP150�U /M D /830 -- 15 0 JUNO T2WH 24" SINGLE CIRCUIT TRACK 1 120 - X TRANSFORMER 41111 2 NOT APPLICABLE 8 3 E JUNO T4WH 48" SINGLE CIRCUIT TRACK 1 120 X 20 12 9274 NOT APPUCABLE . 19 1060�78� F JUNO T6WH 72" SINGLE CIRCUIT TRACK 1 120 10 X 1111111ii, €r: 9011 f NOT APPUCABLE 6 ---- 7 G JUNO T8WH 96" SINGLE CIRCUIT TRACK 1 120 2520 X SHOWWINDOW DOWN -� to 8 10 12 NOT APPLICABLE 20 27 - H JUNO T38WH LIVE END POWER FEED 1 120 11 X 1333 Mal mullimeignilli NOT APPLICABLE -- r J JUNO T23WH CENTER "MINI - CONNECTOR" FEED 1 120 pm= X 12 R 25% LTG AND SIGN 4125 NOT APPUCABLE 14 SUB TOTALS L JUNO T5T22WH WALL WASHER 1,2 120 DEMAND AMPERES 49.0 X 1 2 24 55 FP24/8 0 /HO I 1 R 90 �j M JUNO TM232 -70E- NFL -WH TRACK HEAD 1,2 120 1350 X 12 20 1 70 75 SYLVANIA MC7OTC /U/G8.5/830 3 © Q HUBBELL CF8P42TEBCRWH 6" VERICAL OPEN CYLINDER 1,7 120 X 15 1 42 45 SYLVANIA CF42DT/ E /IN /830 /ECO 11 1 R HUBBELL CS4- 232 -EB8 4' 2 -LAMP FLOURESCENT STRIP FIXTURE 3,4 120 540 REC- MANAGERS DESK X 2 32 e SYLVANIA F032/835/ECO 1 1 5 ® X BEST EZXTEU2RW RED LED EXIT SIGN - WHITE 1,7 120 20 X R 1140 -- -- 10 INCLUDED 15 jQ EM BEST R1 -WH EMERGENCY LIGHT 2 -HEAD 1,7 120 - 1590 X X -- -- 10 INCLUDED 2 REC - REFRIGERATOR Z TEIBER TFL9OL COMBINATION LIGHT AND EXHAUST FAN 1 120 X L 12 20 1 60 165 SYLVANIA 60A /HAL /M B -19 20 /d R 1200 1. LAMPS AND FIXTURES SUPPLIED BY WET SEAL AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. 2. REFER TO DETAIL #2/E102 FOR MOUNTING. 3. LIGHT FIXTURES TO BE CHAIN HUNG AT 12' -0" A.F.F. IN STOCK ROOM WHEN NO CEILING IS PRESENT. SURFACE MOUNT IF CEILING PRESENT. 4. FIXTURES SHOWN WITH CROSS -HATCH ARE TO BE NIGHT UGHTS. FIXTURES USED FOR EXIT, EMERGENCY, OR NIGHT LIGHTING TO BE ON LOCKOUT CIRCUIT. SYMBOL LEGEND DESIGNATION! MP cb 0 SM * ra di o ,:' 4 ��'I 4 INSTALL 100 UNIPLEX RECEPTACLE (SINGLE) DUPLEX RECEPTACLE DUPLEX FLOOR MOUNTED DUPLEX ISOLATED GROUND DUPLEX FLOOR MTD ISO GRD DUPLEX SPECIAL LOCATION QUADPLEX RECEPTACLE QUADPLEX FLOOR MOUNTED QUADPLEX ISOLATED GROUND QUADPLEX FLOOR MTD ISO GRD QUADPLEX SPECIAL LOCATION SPECIAL VOLTAGE OR AMPERAGE SPECIAL VOLTAGE OR AMPERAGE MULTI - OUTLET PLUGMOLD TELEPHONE OUTLET JUNCTION BOX DATA OUTLET DOORBELL PUSHBUTTON DOORBELL DOORBELL LOW -VOLT TRANS LOW - VOLTAGE TRANSFORMER DISCONNECT SWITCH TELEPHONE BOARD ELECTRICAL PANEL TRANSFORMER 24HR 7 DAY -TIME CLOCK WALL SWITCH 3 #12, 3/4 "C (2 CKT WIRES, 1 NEUTRAL, 1 GROUND) CIRCUIT HOME RUN CONDUIT THRU /BELOW FLOOR CONDUIT STUBBED UP /DOWN NIGHT LIGHT TIMECLOCK CONTROLED CIRCUIT • Q Q p s' a 11 ❑J d-b ® RELOCATED EXIST KVA WIRE, SOLID MTD T/C AMPERE $ 1} ----'-a - - - - 0— N.L. VIA T/C CONTRACTOR'S NOTES A. ELECTRICAL CONTRACTOR SHALL VISIT AND EXAMINE THE SITE PRIOR TO CONSTRUCTION TO ASCERTAIN THE EXISTING CONDITIONS AND LIMITS OF CONSTRUCTION. B. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROTECT AND RETAIN POWER TO ALL EXISTING ACTIVE EQUIPMENT WHICH SHALL REMAIN. C. ALL REMOVED EQUIPMENT SHALL BE DISPOSED OF BY THIS CONTRACTOR UNLESS DIRECTED TO DO OTHERWISE. D. DISCONNECT, REMOVE, OR RELOCATE ALL EXISTING ELECTRICAL MATERIAL AND EQUIPMENT THAT INTERFERES WITH THE NEW INSTALLATION. THIS INCLUDES BUT IS NOT LIMITED TO PANELS, LIGHTING FIXTURES, WIRING DEVICES, SIGNAL EQUIPMENT, EXHAUST FANS, BASEBOARD HEATERS, UNIT HEATERS, ETC. E. SEE MECHANICAL DRAWINGS FOR HEATERS, EXHAUST FANS, ETC., WHICH MUST BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL OR ABANDONMENT BY THE MECHANICAL CONTRACTOR. F. REMOVE ALL CONDUIT, WIRE, BOXES, AND FASTENING DEVICES AS REQUIRED, TO AVOID ANY INTERFERENCE WITH THE NEW INSTALLATION. G. ELECTRICAL CONTRACTOR SHALL RECONNECT ANY EQUIPMENT BEING DISTURBED BY THIS RENOVATION, YET REQUIRED FOR CONTINUED SERVICE, TO THE SAME OR THE NEAREST AVAILABLE PANEL. H. WHERE WORK BY THE GENERAL CONTRACTOR (WALL REMOVAL, NEW OR RELOCATED WALL OPENING, ETC.) RESULTS IN THE REMOVAL, RELOCATION, OR REFEEDING OF ELECTRICAL DEVICES, THE ELECTRICAL CONTRACTOR SHALL DISCONNECT OR RECONNECT, AS REQUIRED, ALL ACTIVE DEVICES REMAINING ON THAT CIRCUIT SYSTEM. I. CONTRACTOR SHALL RING OUT ALL CIRCUITS IN EXISTING PANELS EFFECTED BY THIS ALTERATION. WHERE ADDITIONAL CIRCUITS ARE NEEDED, RE -USE CIRCUITS AVAILABLE FOR RE -USE, OR PROVIDE NEW BREAKERS. TAG ALL UNUSED CIRCUITS AS SPARE AND REPLACE ALL INOPERATIVE OR DEFECTIVE CIRCUIT BREAKERS. TIGHTEN ALL CONNECTIONS. J. ELEC. CONTRACTOR IS TO FIELD VERIFY CONDITION OF EXISTING ELEC. EQUIPMENT AND RELOCATE AS REQUIRED. IF EXISTING EQUIPMENT IS NOT IN WORKING CONDITION CONTRACTOR SHALL PROVIDE NEW EQUIPMENT AS REQUIRED. SUB CONTRACTORS TO REVIEW DWG. T100 BEFORE BEGINNING WORK EACH CONTRACTOR SHALL WARRANTY HIS WORK FOR ONE (1) YEAR FROM THE OPENING DATE OF THE STORE ALL CONTRACTORS SHALL PERFORM THIER WORK ACCORDING TO STATE AND /OR LOCAL CODES. ALL OF THE ELECTRICAL WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR HIS REPRESENTATIVE SHALL BE PART OF HIS CONTRACT. THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. RECEPTACLE AND SWITCHED LIGHT PROVIDED BY E.C. TO BE INSTALLED PER N.E.C. 210 -63 & 210 -70c NEW 2 #12, 3/4"C TIMECLOCK FOR STOREFRONT ---•-- RECEPTACLE FOR TELEPHONE. VERIFY EXACT LOCATION ■ (2)NEW 480V, 30, 3iA.S., FOR (2)NEW VAV 6.4 F.L.A. 4KW HEATER (2)NEW SETS 4 #12, 3/4 "C 1 #12 GND NEW 4 #3, 1-1/4"C 8 GND 9A.F. PULL BOX ROOF UNE EXIST CONDUIT BY LANDLORD EXIST 4 #3/0 1 6 GND PANEL LP PANEL MP TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AN IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH (1/8") THICK PLASTIC, BLACK ON WHITE AND ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1") WITH WITH ONLY THE TENENAT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANENTLY AFFIXED. NDLORD PROVIDED MASTER METERING EQUIPMENT IN THE LANDLORDS ELECTRICAL ROOM. THE LANDLORD OWNED NETWORK METERING SYSTEM WILL METER TENANTS POWER CONSUMPTION. REFER TO PANEL SCHEDULE REFER TO PANEL SCHEDULE EXIST 200A.S. WITH 200A.F. SERVICE FROM LANDLORD 277/480V, 30, 4W ELEC. DISTRIBUTION EQUIPMENT NEW 4 #1, 1- 1 /2 "C�o 1 #6 GND 1 #6 GND TO BLDG STEEL NEW 3 #4, 1"C 1 #8 GND ■ NEW 45KVA, 30 TRANSFORMER LEASE LINE 480/1201208V RELO. 200 A.S. E.C. TO PROVIDE NEW 100 A.F. IF NOT EQUIPED W/ FUSE ELECTRICAL ONE -LINE DIAGRAM WALE NONE 1. ALL WIRE SHALL BE COPPER ONLY, THW, THWN, THHW, OR NEC APPROVED EQUAL OR BETTER. ALL WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED ON NEC 110 -14c AND TABLE 310-16. 2. E.C. SHALL FURNISH ALL NEW ELECTRICAL EQUIP. (PANELS, TRANSFORMER, CONDUITS, WIRE, METERS, SERVICE FEEDERS AND CONDUIT, DISC SWITCHES, CONTACTORS, TIMECLOCKS, ETC) AS REQUIRED, UNLESS NOTED OTHERWISE. GYP BOARD CEILING BALLAST 1 FLOOR LINE 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, UGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING USED SHALL BE REMOVED FROM THE SITE. DO NOT ABANDON IN PLACE. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. IF DISCREPANCIES ARISE CONTACT PROJECT REP. ADJUSTABLE BRACKETS SALES AREA BAY LIGHT TYPE 'B' SCALE: 3'" - 1-0' PANELBOARD 277/480 DESIGNATION! MP NEW SURFACE INSTALL 100 X EXIST BUS LOCATION 100 AMPERE RELOCATED EXIST VOLTS 3 PHASE 4 WIRE, SOLID MTD NEUTRAL AMPERE MAIN BREAKER TOP FED X BOTTOM FED FLUSH MTD X CKT # DESCRIPTION WATTS LOAD TYPE WIRE SIZE BRKR SIZE a A B C .g a°. BRKR SIZE WIRE SIZE LOAD TYPE WATTS DESCRIPTION CKT 1 VAV 1333 H 112 15 3 10586 3 70 * - 9253 TRANSFORMER 41111 2 3 LTG- SHOWWINDOW 900 •• 10 20 1 20 12 9274 540 . 4 4 1060�78� 1440 5 5 1776 �M. L 10 :.;; 1111111ii, €r: 9011 f - 6 20 7 VAV 1776 H 'k 15 3 —�— 1776 2520 DLTG- SHOWWINDOW DOWN -� to 8 10 12 133 20 -1 1288 9 1334 - . 20 12 R 11 REC- SENSORMATIC 1333 Mal mullimeignilli 3.. lalP37);„;a1 LTG-TRACK 24' 1800 L 12 20 pm= 20 12 R 25% LTG AND SIGN 4125 REC - SHOWWINDOW 10 SUB TOTALS L = LTG OR SIGNAGE R = RECEPTACLE H = MISCELLANEOUS K = K K = KITCHEN 12362 11942 12120 25% LARGEST MOTOR 111 CONNECTED PHASE BALANCE LOAD 36424 DEMAND LOAD 40659 DEMAND AMPERES 49.0 3.4% 1 NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK * - REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT T/C T/C C T C F RENAMED FOR CODE CO NFPA 70 - NEC APR 2, 5 2Ot Of Tukwil IoN B ID% DM. EVIStOM N0.1 PANELBOARD 120/208 DESIGNATION LP NEW SURFACE INSTALL 125 X EXIST BUS LOCATION 125 RELOCATED EXIST VOLTS 3 PHASE 4 WIRE, SOLID MTD NEUTRAL AMPERE AMPERE MAIN BREAKER TOP FED BOTTOM FED X FLUSH MTD CKT # DESCRIPTION WATTS LOAD TYPE WIRE SIZE BRKR SIZE J 0_ 1 1 A B C BRKR SIZE WIRE SIZE LOAD TYPE WATTS DESCRIPTION CKT # 1 SIGN - STOREFRONT 1200 L 12 20 -I 2280 1 20 12 R 1080 REC - P.O.S. 2 1 3 LTG- SHOWWINDOW 900 L 10 20 1 20 12 R 540 REC - CASHWRAP 4 4 1440 5 LTG- SHOWWINDOW 1800 L 10 20 1 1 1 - 1 20 12 R 720 REC- BACKWRAP 6 2520 DLTG- SHOWWINDOW DOWN 74-8 L 10 20 -1 1288 1 20 12 R 540 REC- SENSORMATIC 8 1 9 LTG-TRACK 24' 1800 L 12 20 1 20 12 R 180 REC - SHOWWINDOW 10 1980 11 LTG TRACK 24' 1800 L 12 20 1 - 1 20 12 R 360 REC- SHOWWINDOW 12 2160 13 LTG -TRACK 18' 1350 L 12 20 1 2790 1 20 12 R 1440 REC - GENERAL 14 15 LTG -TRACK 18' 1350 L 12 20 1 1 20 12 R 540 REC- MANAGERS DESK 16 1890 17 LTG -TRACK 24' 1800 L 12 20 1 - 1 20 12 R 1140 REC - STOCK/TOILET /HVAC 18 2940 19 LTG -SALES HIGHBAY 1050 L 12 20 1 - 1590 1 20 12 R 540 REC - REFRIGERATOR 20 21 LTG - BACKWRAP 500 L 12 20 1 1 20 12 R 1200 REC - MICROWAVE 22 1700 23 LTG - CASHWRAP 135 L 12 20 1 - 1 20 12 R 540 REC -SOUND SYSTEM 24 675 25 LTG - FITTING ROOM 585 L 12 20 1 - 1305 1 20 12 M 720 PHONE /CLOCK /BELL 261 27 LTG - STOCK /TOILET 764 L 12 20 1 1 20 12 M 1500 WATER HEATER 28 2264 129 LTG - EXIT /EMERG /NL 716 L 12 20 1 - 1 20 - - -- SPARE 30 716 31 SPARE -- - - - - - -- 1 20 - - -- SPARE 32 33 SPARE -- - - 1 20 - - -- SPARE 34 35 SPARE -- - - 1 20 - - -- SPARE 36 37 '�.� fu:,, 114104= � c..� �`• ors; %; -- iurt µ�:����ES.: i 6��fEE�f �...,,,... �::'"' ,g7 /, r3 38 3�tA 39 r .g..l, . .. s ixxM iM. E; ; %q;�"""" �.� "'R 'L:!tf.:a i5:.::� • :. di� '��.i��i�.`:2?3:.i./i %.�,5}i�, 40 , ss� �� 41 .,.,..,.,.,.b33f3.. #. i � i .. HS ,.c.:a '.[s <'s:6: %5� ¢.�3 � � 3.,.... ,,,,,,, , , 'i3i' ,'3,,,,3,'3,'333 H13,i3: i ,s .3�» N3„ i3� 42 . .,.�" ,.....v,,,,,,,,,, 25% LTG AND SIGN 4125 SUB TOTALS L = LTG OR SIGNAGE R = RECEPTACLE M = MISCELLANEOUS H = H.V.A.C. K = KITCHEN 9253 9274 9011 DEMAND LOAD 31663 CONNECTED PHASE BALANCE LOAD 27538 DEMAND AMPERES 88.0 2.8% NOTE: ALL BREAKERS SHALL BE BOLT -ON, UNLESS OTHERWISE NOTED. • - INDICATES THIS CIRCUIT TO RECIEVE HANDLE LOCK -ON CUP T/C - INDICATES THIS CIRCUIT TO BE CONTROLED BY A TIMECLOCK * - REFER TO ONE -LINE DIAGRAM FOR WIRE SIZE TO THIS EQUIPMENT ELO9 3:Lil T/C T/C f 5 co of m 1 RECEIVE( APR 2 2 2006 PERMIT CENTEh r GI U 0 LL Q CC 0 0 c01 LL! O c.1 tr3 o10 E102 DMSION 16 - ELECTRICAL SPECIFICA11ONS SECTION 16100 ELECTRICAL SPECIAL CONDEMNS 1. A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION ", AND DIVISION 1 GENERAL CONDITIONS GOVERN WORK UNDER THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. B. APPLICABLE PROVISIONS OF THIS SECTION GOVERN WORK UNDER ALL OTHER SECTIONS OF DIVISION 16. WORK COVERED BY THIS SECTION SHALL CONSIST OF PROVIDING ALL MATERIAL, LABOR, EQUIPMENT AND SERVICES NECESSARY FOR A COMPLETE, TESTED AND ADJUSTABLE ELECTRICAL INSTALLATION READY FOR OPERATION AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. C. THE TERM CONTRACTOR AS USED IN THIS SECTION SHALL MEAN ANY CONTRACTOR OR SUBCONTRACTOR WHO HAS CONTRACTED TO PERFORM WORK INCLUDED IN AND DEFINED BY THIS SECTION AND ALL OTHER SECTIONS OF DIVISION 16. 2. CONTRACTOR'S RESPONSIBILITY A. PRIOR TO SUBMITTING HIS BID, CONTRACTOR SHALL CAREFULLY EXAMINE THESE CONSTRUCTION DOCUMENTS, THE DEVELOPER'S EXHIBITS, AND THE SITE, TO INQUIRE FULLY INTO DIFFICULTIES AND COSTS OF WORK, AND TO DETERMINE THE SCOPE AND CHARACTER OF WORK TO BE DONE. CONTRACTOR SHALL INCLUDE ALL NECESSARY COSTS TO LOCATE AND /OR EXTEND ALL UTILITIES INCLUDING UGHTING PANELS, POWER PANELS, ELECTRICAL SERVICE, PHONE SERVICE AND /OR MODIFY EQUIPMENT TO MEET THE INTENT OF THE CONTRACT DOCUMENTS. THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER SHALL NOT BE RESPONSIBLE FOR FAILURE OF THE CONTRACTOR TO DETERMINE DIFFICULTIES AND COSTS IN THE PROJECT OR FOR HIS OVERLOOKING OF THE REQUIREMENTS. B. IF THIS CONTRACTOR DOES NOT CLEARLY UNDERSTAND THE PLANS AND SPECIFICATIONS, OR IF THERE ARE ANY REQUIREMENTS WHICH ARE AMBIGUOUS IN THE CONTRACTOR'S OPINION, HE SHOULD CALL THIS TO THE ATTENTION OF THE ARCHITECT PRIOR TO BIDDING, SINCE THIS CONTRACTOR WILL BE HELD RIGIDLY TO THE INTERPRETATIONS OF THE ARCHITECT AND ENGINEER. C. CONTRACTOR SHALL SCHEDULE HIS WORK IN COOPERATION WITH OTHER TRADES INSTALLING INTERRELATED WORK. ALL WORK SHALL BE SCHEDULED TO MAINTAIN SERVICE TO ALL REQUIRED AREAS DURING THE COURSE OF THE CONSTRUCTION EXCEPT FOR SHORT TERM PLANNED SHUTDOWNS, ANY OF WHICH SHALL BE PRE - SCHEDULED WITH THE OWNERS AGENT AND THE LANDLORD. 3. WORKMANSH P AND G A. IN ENTERING INTO A CONTRACT COVERING THIS WORK, THE CONTRACTOR ACCEPTS THE SPECIFICATIONS, AND GUARANTEES THAT THE WORK WILL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. CONTRACTOR FURTHER GUARANTEES THAT THE WORKMANSHIP AND MATERIAL WILL BE OF THE BEST PROCURABLE AND THAT NONE BUT EXPERIENCED WORKMEN EXPERIENCED IN EACH PARTICULAR CLASS OF WORK WILL BE EMPLOYED. CONTRACTOR FURTHER GUARANTEES TO REPLACE AND MAKE GOOD AT HIS OWN EXPENSE ANY DEFECTS DUE TO FAULTY WORKMANSHIP OR MATERIAL WHICH MAY DEVELOP WITHIN ONE (1) YEAR AFTER FINAL PAYMENT AND ACCEPTANCE BY THE ARCHITECT. 4. CODES AND STANDARDS A. CONTRACTOR WILL COMPLY IN ALL RESPECTS WITH THE ADOPTED BUILDING CODES, APPLICABLE LAWS, ORDINANCES, AND REGULATIONS AS MAY APPLY ACCORDING TO THE RULING OF THE CONTROLLING PUBLIC OFFICIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE REQUIREMENTS OF THE APPLICABLE LAWS, ORDINANCES AND REGULATIONS, OR WHICH DOES NOT RECEIVE THE APPROVAL OF THE CONTROLLING PUBLIC OFFICIAL, HE SHALL BEAR ALL COSTS ARISING IN CORRECTING THE DEFICIENCIES. ALL ELECTRICAL EQUIPMENT SHALL SHALL BEAR THE UNDERWRITER'S LABORATORY LABEL. 5. FEES ON PERMITS A. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND MAKING PAYMENT FOR ALL FEES, PERMITS AND INSPECTIONS RELATING TO HIS WORK. 6. CONTRACT DRAWINGS A. THE DRAWINGS SHOW THE GENERAL ARRANGEMENT AND INTENT OF THE DESIGN AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL BUILDING CONDITIONS AND THE WORK OF OTHER TRADES WILL PERMIT. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES WHICH MAY BE REQUIRED, NOR IS IT IMPLIED THAT ALL CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE SYSTEMS OR BUILDING COMPONENTS HAVE BEEN INDICATED. THE CONTRACTOR SHALL INVESTIGATE ALL EXISTING CONDITIONS AFFECTING THE WORK AND ARRANGE HIS WORK ACCORDINGLY, PROVIDING SUCH FITTINGS, OFFSETS, ACCESSORIES AND DEVICES AS MAY BE REQUIRED. THE DRAWINGS AND SPECIFICATIONS ARE MUTUALLY COMPLEMENTARY, AND ANY WORK REQUIRED BY ONE BUT NOT BY THE OTHER SHALL BE PERFORMED BY BOTH. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS AND SERVICES REQUIRED FOR A COMPLETE AND WORKING PROJECT AT NO ADDITIONAL COST EVEN THOUGH EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN EACH AND EVERY NECESSARY ELEMENT THEREOF IS NOT SPECIFICALLY IDENTIFIED HEREIN. B. CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS BUT SHALL FOLLOW THE ARCHITECTURAL DRAWINGS OR EXISTING BUILDING CONDITIONS WHERE APPLICABLE, IN ESTABLISHING DIMENSIONS AND LINES OF RUN, SINCE DIMENSIONS ON THE FINAL ARCHITECTURAL DRAWINGS OR AT THE SITE MAY NOT COINCIDE WITH THOSE SHOWN ON THE ELECTRICAL DRAWINGS, THE CONTRACTORS SHALL VERIFY WITH THE DIMENSIONED ARCHITECTURAL DRAWINGS OR THE SITE CONDITIONS THE EXACT MATERIAL QUANTITIES AND LENGTHS NECESSARY. C. SIGNIFICANT DEVIATIONS OR CHANGES FROM THE DRAWINGS WHICH ARE REQUIRED TO ACCOMPLISH THE INTENT OF THE CONTRACT DOCUMENTS MUST BE REVIEWED WITH THE ARCHITECT AND APPROVED BEFORE PROCEEDING. 7. SHOP DRAWINGS A. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS, FOUR (4) COPIES MINIMUM, FOR ALL MANUFACTURED PRODUCTS. EACH SHOP DRAWING SHALL BE REVIEWED BY THE CONTRACTOR PRIOR TO SUBMITTAL TO ASSURE THAT ALL DIMENSIONS, QUANTITIES, CONNECTIONS, CAPACITATES AND ACCESSORIES SHOWN ARE IN CONFORMANCE WITH THE CONTRACT DOCUMENTS, AND SHALL BE MARKED OR STAMPED TO CONFIRM THAT SUCH REVIEW WAS MADE AND COMPLIANCE WAS CONFIRMED. B. APPROVAL OF SHOP DRAWINGS BY THE OWNER, OWNER'S AGENT, ARCHITECT, ENGINEER OR DESIGNER, WILL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF COMPLYING WITH ALL TERMS OF THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR PERFORMANCE OF ALL EQUIPMENT PURCHASED, FOR PROPER FIT, AND OTHER DIMENSIONAL REQUIREMENTS. 8. ,RECORD DRAWINGS A. CONTRACTOR SHALL MAINTAIN AT THE JOB SITE ONE SET OF DOCUMENTS AS "RECORD DRAWINGS" FOR THE PURPOSE OF DAILY MARKING OF ALL SUBSTANTIAL REVISIONS TO THE DOCUMENTS INCLUDING BUT NOT LIMITED TO ELECTRICAL CHANGES, AND LOCATIONS OF UTILITIES, PANELBOARDS, DISCONNECTS, STARTERS AND OTHER DEVICES REQUIRING PERIODIC OPERATIONAL ATTENTION, ADJUSTMENT, OR SERVICE INCLUDING ACCESS THERETO, AT THE COMPLETION OF THE PROJECT, THIS SET SHALL BE RETURNED TO THE ARCHITECT FOR THE PURPOSE OF MAKING FINAL "AS -BUILT DRAWINGS ". 9. EQUIPMENT SUBSTITUTION A. SPECIFIC MANUFACTURERS AND MODELS OF EQUIPMENT HAVE BEEN USED IN THE DEVELOPMENT OF THE DRAWINGS AND DESIGNS. THIS CONTRACTOR MUST SUBMIT TO THE OWNER ANY CHANGES AND /OR SUBSTITUTIONS FOR APPROVAL PRIOR TO INSTALLATION OR EXECUTION. ANY CHANGES WHICH DO NOT RECEIVE THE OWNER'S APPROVAL MAY BE SUBJECT TO REMOVAL OR REPLACEMENT AS ORIGINALLY SPECIFIED, AND WILL BE AT THE CONTRACTOR'S EXPENSE. B. IF THIS CONTRACTOR SUBSTITUTES FOR SPECIFIED EQUIPMENT ANY OTHER EQUIPMENT WHICH REQUIRES ANY CHANGES TO THE DESIGN, ALL COST OF REDESIGN AND RECONFIGURATION RESULTING FROM SAID SUBSTITUTION SHALL BE BORNE BY THE SUBMITTING CONTRACTOR. 10. EQUIPMENT INSTALLATION AND SUPPORT A. CONTRACTOR SHALL SUPPORT PLUMB, RIGID AND TRUE -TO -LINE ALL WORK AND EQUIPMENT INSTALLED. THIS CONTRACTOR SHALL DETERMINE HOW EQUIPMENT, FIXTURES, ETC., ARE TO BE SUPPORTED, MOUNTED, OR SUSPENDED AND SHALL PROVIDE ACCESSORIES REQUIRED FOR PROPER SUPPORT WHETHER SHOWN ON THE DRAWINGS OR NOT. IF SUPPORTS ARE REQUIRED, CONTRACTOR SHALL SUBMIT DRAWINGS TO THE ARCHITECT FOR APPROVAL. B. PRODUCTS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS PRINTED INSTALLATION AND MAINTENANCE LITERATURE. COMPONENTS REQUIRING PERIODIC MAINTENANCE OR ADJUSTMENTS SHALL BE LOCATED OR INSTALLED AS TO PERMIT ACCESS WITHOUT DAMAGE TO STRUCTURE, FINISHES OR OTHER EQUIPMENT. C. ALL CONDUIT CONNECTING TO SWITCHGEAR, PANELS, MOTORS, AND OTHER EQUIPMENT SHALL BE INSTALLED WITHOUT STRAIN AT THE CONNECTIONS. THE CONTRACTOR MAY BE REQUIRED, AS DIRECTED, TO DISCONNECT CONDUITS TO DEMONSTRATE THAT THEY HAVE BEEN SO CONNECTED 11. DEMOLITION A. ALL EXISTING EQUIPMENT, NOT INDICATED TO BE INCORPORATED INTO THE NEW SYSTEM SHALL BE DISCONNECTED BY THIS CONTRACTOR FOR REMOVAL BY OTHERS FROM THE JOB SITE. CARE SHALL BE USED SO THAT NO DAMAGE IS DONE TO EXISTING BUILDING, PIPING, DUCTWORK, AND /OR ELECTRICAL EQUIPMENT. ANY DAMAGE ATTRIBUTED TO THIS CONTRACTOR SHALL BE REPAIRED OR REPLACED BY THIS CONTRACTOR. 12. CUTTING AND PATCHING A. ALL CUTTING THAT MAY BE NECESSARY FOR THE INSTALLATION OF THE WORK OR ANY REQUIRED PATCHING THAT RESULTS THEREFROM SHALL BE DONE BY THE PROPER TRADE INVOLVED AND SHALL BE INCLUDED AS PART OF THIS CONTRACT. PATCH TO DUPLICATE UNDISTURBED ADJACENT FINISHES, COLORS, TEXTURES AND PROFILES. COLUMNS, BEAMS, GIRDERS OR JOISTS SHALL NOT BE CUT. B. ALL WORK AFFECTING ROOF OR STRUCTURES SHALL BE PERFORMED BY LANDLORD'S CONTRACTOR AT TENANT'S EXPENSE. 13. CLEANING A. COMPLETION AS IT PERTAINS TO THE CONTRACT COMPLETION DATE I5 DEFINED AS THE DAY THE PROJECT IS TURNED OVER TO THE OWNER IN THOROUGHLY CLEAN CONDITION. READY FOR THE OWNER TO TAKE POSSESSION. ALL FIXTURES, MOTORS, EQUIPMENT AND ALL OTHER ELECTRICAL EQUIPMENT FURNISHED OR INSTALLED BY THE CONTRACTOR SHALL BE THOROUGHLY CLEANED. 14. Ens A. PROVIDE THE TESTS AS OUTLINED HEREINAFTER AND OTHER TESTS NECESSARY TO ESTABLISH THE ADEQUACY, QUALITY, SAFETY, COMPLETED STATUS AND SUITABLE OPERATION OF EACH SYSTEM. CORRECT PROMPTLY ANY FAILURE OR DEFECTS REVEALED BY THESE TESTS AND RECONDUCT TEST ON THE CORRECTED ITEMS. B. TEST THE GROUNDS WITH A GROUND RESISTANCE DIRECT READING SINGLE-TEST MEGGER. C. INSULATION RESISTANCE BETWEEN PHASE CONDUCTORS AND GROUND NOT LESS THAN 1,000,000 OHMS. D. THE PANELBOARDS SHALL HAVE PHASE CURRENTS BALANCED TO WITHIN +/- 10% VARIATION BETWEEN AVERAGE PHASE CURRENT AND MEASURED INDIVIDUAL PHASE. E. AN OPERATIONAL TEST OF THE EMERGENCY LIGHTS AND THE EXIT LIGHTS SHALL BE PERFORMED FOR THE OWNER TO DEMONSTRATE CONFORMANCE TO THE SPECIFICATIONS. 15. TEMPORARY ELECTRICAL SERVICE (N /A) A. TEMPORARY ELECTRICAL SERVICE SHALL BE IN ACCORDANCE WITH THE BUILDING CODE. TEMPORARY UGHTING SHALL BE PROVIDED BY A LAMP LOCATED FOR EVERY 625 SQUARE FEET OF BUILDING AREA WITH A MINIMUM OF ONE PER ROOM. THE LAMP TO BE 100 WATT AND SHALL BE MAINTAINED BY THE GENERAL CONTRACTOR. B. TEMPORARY POWER DISTRIBUTION SHALL BE SUFFICIENT TO ACCOMMODATE THE TEMPORARY LIGHTING AND CONSTRUCTION OPERATIONS, INCLUDING THE USE OF POWER TOOLS (BUT NOT INCLUDING HEAVY -DUTY ELECTRICAL WELDING UNITS), ELECTRICAL HEATING UNITS, AND START -UP OF SPECIFIED BUILDING EQUIPMENT, WHICH IS TO BE TESTED, STARTED OR PLACED INTO OUR USE PRIOR TO COMPLETION OF ITS PERMANENT POWER CONNECTIONS. 16. EXCAVATION AND BACKF7LJ. A. CONTRACTOR SHALL DO ALL EXCAVATION REQUIRED AS SHOWN ON PLANS OR REQUIRED FOR PROPER OPERATION. EXCESS EXCAVATION BELOW THE REQUIRED LEVEL SHALL BE BACKFILLED WITH EARTH AND THOROUGHLY TAMPED. UTILITY SERVICES, SHALL BE INSPECTED AND APPROVED BY THE PROPER INSPECTION AUTHORITY BEFORE BACKFIWNG. SECTION 16200 ELECTRICAL POWER AND LIGHTING 1. RELATED DOCUMENTS A. APPLICABLE PROVISIONS OF AIA DOCUMENT A201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION ", DIVISION 1 GENERAL CONDITIONS AND SECTION 16100 ELECTRICAL SPECIAL CONDITIONS GOVERN WORK UNDER THIS SECTION. B. REFER TO SECTION 16100 ELECTRICAL SPECIAL CONDITIONS REGARDING REGULATIONS AND REQUIREMENTS AFFECTING ALL WORK DESCRIBED IN THIS SECTION. 2. POWER SERVICE A. POWER SERVICE FOR THIS PROJECT SHALL BE PROVIDED FROM THE EXISTING MALL DISTRIBUTION SYSTEM. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH MALL MANAGEMENT TO INSURE THAT ALL WORK AND MATERIALS ARE IN CONFORMANCE WITH THE LANDLORD'S REQUIREMENTS. NAMEPLATES A. ELECTRICAL EQUIPMENT, INCLUDING BUT NOT LIMITED TO PANELBOARDS, DISCONNECTS TRANSFORMERS, CONTROLS, ETC., SHALL BE IDENTIFIED WITH THREE PLY LAMINATED PLASTIC. THE OUTSIDE LAMINATIONS SHALL BE BLACK. ENGRAVING SHALL EXTEND THROUGH THE FRONT LAMINATION SO THAT THE BLACK LETTERS APPEAR ON A WHITE BACKGROUND. NAMEPLATES SHALL BE PERMANENTLY ATTACHED WITH SCREWS. B. CIRCUIT DIRECTORY SHALL BE TYPEWRITTEN (HANDWRITTEN IS NOT ACCEPTABLE) AND SHALL IDENTIFY CIRCUIT AS TO TYPE AND LOCATION AS FOLLOWS: "LTG" --- FOR LIGHTING CIRCUIT FOLLOWED BY AREA IN WHICH CIRCUIT APPEARS, I.E., "STOCKROOM ", "CASH WRAP ", ETC. " RECEPT" -- FOR RECEPTACLE CIRCUIT FOLLOWED BY AREA IN WHICH RECEPTACLE APPEARS, "STOREFRONT ", "CASH REGISTER ", ETC. "MOTOR" - FOR MOTOR FOLLOWED BY THE EQUIPMENT IDENTIFICATION AND AREA IN WHICH MOTOR IS LOCATED, I.E. "EXH FAN TOILET ", "AHU- ROOF ", ETC. 3. 4. CONDUIT A. ALL WIRING SHALL BE RUN IN CONDUIT. THIN WALL EMT CONDUIT SHALL BE USED SIZES 1/2" THROUGH 2 -1/2 ". ALL CONDUITS LARGER THAN 2 -1/2" SHALL BE HEAVYWALL. CONDUITS INSTALLED UNDERGROUND OR IN CONCRETE SLABS SHALL BE PVC JACKETED FLEXIBLE STEEL CONDUIT (SEALTITE) SHALL BE USED IN WET AREAS AND ON ALL MOTORIZED EQUIPMENT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS, AT A MAXIMUM LENGTH OF 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC. SHALL BE ALLOWED. B. ALL OPENINGS IN FIRE AND SMOKE WALLS, PARTITIONS, FLOORS AND OTHER SIMILAR PENETRATIONS FOR ELECTRICAL CONDUITS, CABLE OR EQUIPMENT, WHETHER CUT OR IN PLACE, SHALL BE CLOSED WITH A UL APPROVED FIRE RESISTANT SILICONE FOAM SEALANT TO MAINTAIN THE FULL RATING AND INTEGRITY OF THE PARTITIONS, WALLS OR FLOOR. C. CONDUIT BENDS FOR POWER AND LIGHTING CIRCUITS SHALL NOT BE LESS THAN STANDARD RADIUS BENDS. CONDUIT BENDS FOR FEEDERS, TELEPHONE AND COMMUNICATION CIRCUITS SHALL NOT BE LESS THAN LONG RADIUS BENDS. D. O.Z. TYPE DX, TX, OR AX CONDUIT EXPANSION DEFLECTION FITTINGS ARE REQUIRED IN ALL CONDUIT RUNS WHERE MOVEMENT MAY BE ENCOUNTERED. ALL EMT COUPLINGS SHALL BE COMPRESSION TYPE. E. EXPOSED CONDUIT SHALL BE SECURELY SUPPORTED IN PLACE PER CODE BUT ON A MAXIMUM OF 10 FOOT INTERVALS, WITHIN THREE FEET OF EACH BEND, AT EVERY OUTLET OR JUNCTION BOX AND AT THE END OF EACH STRAIGHT RUN TERMINATING AT A BOX OR CABINET. CONDUIT SHALL NOT BE SUPPORTED FROM DUCTWORK OR PIPE WORK. CONDUITS SHALL BE RUN PARALLEL TO AND AT RIGHT ANGLES TO THE BUILDING LINES. GENERALLY, CONDUIT SHALL BE RUN IN CONTACT WITH STRUCTURAL PARTS OF THE BUILDING SO AS TO AVOID SUSPENDED LENGTHS OF CONDUIT. CONDUIT SHALL BE INSTALLED AS TO BE ACCESSIBLE FOR REPLACEMENT AND MAINTENANCE AND GENERALLY CONDUIT SHALL BE INSTALLED TO PERMIT DRAINAGE. 5. WIRE AND CABLE A. ALL WIRE AND CABLE SHALL BE RUN IN CONDUIT. ALL WIRE AND CABLE FEEDERS AND BRANCH CIRCUITS SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE CURRENT EDITION OF THE NEC AND SHALL MEET ALL ASTM SPECIFICATIONS. WIRE AND CABLE SHALL BE NEW, SHALL HAVE SIZE, GRADE OF INSULATION VOLTAGE AND MANUFACTURER'S NAME PERMANENTLY MARKED ON OUTER COVERING AT REGULAR INTERVAL AND SHALL BE DELIVERED IN COMPLETE COILS OR REELS WITH IDENTIFYING SIZE AND INSULATION TAGS. B. THE ELECTRICAL CONTRACTOR SHALL CALCULATE VOLTAGE DROP ON CONDUCTORS WITH LENGTHS GREATER THAN 75 FEET FROM THE PANELBOARD AND PROPERLY SIZE THE CONDUCTORS PER N.E.C. C. POWER CONDUCTORS: NO WIRE LESS THAN NO. 12 SHALL BE USED EXCEPT FOR CONTROL CIRCUITS OR LOW VOLTAGE WIRING. WIRE SIZES NO. 12 TO NO. 10 SHALL BE SOLID EXCEPT WHERE OTHERWISE INDICATED. WIRE SIZES NO. 8 AND LARGER SHALL BE STRANDED. ALL WIRE SIZES SHOWN ARE AMERICAN WIRE GAUGE SIZES. SIZES NO. 12 AWG THROUGH NO. 8 AWG SHALL BE 'THHN." SIZE 4 AWG AND LARGER SHALL BE "THW." D. CONTINUITY: ALL WIRES SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. E. ACCEPTABLE MANUFACTURERS: CABLE AND WIRE SHALL BE STANDARD TYPE AS MANUFACTURED BY GENERAL CABLE COMPANY, CAROL, ANACONDA, ROM OR ITT ROYAL. 6. COLOR CODING A. A COLOR CODING SYSTEM AS LISTED BELOW SHALL BE FOLLOWED THROUGHOUT FOR FEEDERS AND BRANCH CIRCUITS AND USED AS A BASIS FOR BALANCING LOAD. - - 120/208V: PHASE A-- BLACK, PHASE B - -RED, PHASE C- -BLUE, NEUTRAL -- WHITE, - - 277/480V: PHASE A-- BROWN, PHASE B-- ORANGE, PHASE C-- YELLOW, NEUTRAL - -GRAY, 7. BOXES AND FITTINGS A. ALL OUTLETS SHALL BE PROVIDED WITH GALVANIZED OR SHERARDIZED BOXES SUITABLE IN DESIGN TO THE SPACE THEY OCCUPY AND THE PURPOSE THEY SERVE. WALL MOUNTED OUTLET BOXES, EXCEPT FOR 2" PARTITIONS SHALL BE AT LEAST 1 1/2" DEEP AND /OR DEEPER IF REQUIRED BY THE DEVICE THEY HOLD OR THE NATIONAL ELECTRICAL CODE. GROUND- -GREEN GROUND- -GREEN B. ALL PULLBOXES SHALL BE MADE OF GALVANIZED STEEL, OF METAL GAUGE AND PHYSICAL SIZE AS REQUIRED BY THE NEC FOR THE NUMBER AND SIZE OF RACEWAYS AND CONDUCTORS INVOLVED. C. FIXTURE OUTLET BOXES IN OR ON CEILINGS SHALL NOT BE LESS THAN 1-1/2" DEEP OR LESS THAN 4" SQUARE. ALL OUTLET BOXES INTENDED TO SUPPORT FIXTURES SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS FASTENED THROUGH THE BOTTOM OF THE BOX WITH FOUR BOLTS. 8. CIRCUR BREAKER PANELBOARDS (AS APPLIES) (N /A) A. PANELS SHALL BE DEAD FRONT, SAFETY TYPE, FURNISHED WITH BRANCH CIRCUIT PROTECTING DEVICES, EQUIPMENT GROUNDING BOX, MAIN BUS AND CABLE LUGS FACTORY ASSEMBLED, WITH ALL COMPONENTS IN PLACE, READY FOR INSTALLATION. PROVIDE 20% SPARE BREAKER CAPACITY AND 25% EXCESS AMPACITY IN EACH PANEL. B. CURRENT CARRYING CONTACT SURFACES SHALL BE SILVER OR TIN PLATED. THE CIRCUIT BREAKERS SHALL BE OF THE MOLDED CASE, BOLT -ON TYPE SUITABLE FOR VOLTAGE AND AMPERE RATINGS INDICATED ON DRAWINGS AND IN SCHEDULES AND SHALL HAVE A MINIMUM INTERRUPTING CAPACITY OF 10,000 AMPERES FOR 120/208 AND 14,000 AMPERES AT 277/480. C. MAIN BUSES AND CONNECTORS SHALL BE HARD DRAWN COPPER OF 98% CONDUCTIVITY, WITH CURRENT CARRYING CAPACITY TO MAINTAIN ESTABLISHED RISE TESTS AS DEFINED IN UL STANDARD UL 67. D. CABINET SIZES ARE BASED UPON A 20" WIDE BY 6" DEEP PANEL UNLESS OTHERWISE NOTED. PANELBOARDS SHALL BE EQUIPPED WITH FLUSH TYPE LOCK AND CATCH. ALL LOCKS SHALL BE KEYED ALIKE, AND TWO KEYS ARE TO BE SUPPLIED WITH EACH LOCK. E. PANELBOARDS TO BE BY SQUARE D CORPORATION, GENERAL ELECTRIC COMPANY, OR WESTINGHOUSE. F. IF CIRCUIT BREAKERS ARE TO BE USED AS THE SWITCH CONTROL OF LIGHTING CIRCUITS, THE BREAKERS MUST BE APPROVED FOR THAT USE (TYPE "SWD "). 9. TOGGLE. SWITCHES A. TOGGLE SWITCHES SHALL BE IVORY AND SHALL BE RATED 20 AMPERES 120/277 VOLT AC TYPE AS MANUFACTURED BY HUBBEL AND SHALL BE AS FOLLOWS: SINGLE POLE -- 1221 - -1 THREE WAY -- 1223 - -1 B. TOGGLE SWITCHES SHALL BE MOUNTED 41--0" ABOVE FINISHED FLOOR TO MOUNTING PLATE AND, AT DOORS, INSTALLED ADJACENT TO THE TRIM ON THE STRIKING SIDE OF THE DOOR, REGARDLESS OF THE LOCATION INDICATED ON THE DRAWINGS; THEREFORE, CHECK ALL DOOR SWINGS BEFORE INSTALLATION OF CONDUIT OUTLETS. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SLATER, LEVITON, AND BRYANT WILL BE ACCEPTABLE. 10. RECEPTACLES A. RECEPTACLES SHALL BE WHITE AS MANUFACTURED BY HUBBEL AND SHALL BE AS FOLLOWS: DUPLEX RECEPTACLE - -20A -120 VOLT 5362 -1 B. RECEPTACLES SHALL BE MOUNTED 12" ABOVE THE FINISHED FLOOR UNLESS OTHERWISE NOTED. C. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, SLATER, BRYANT AND LEVITON WILL BE ACCEPTABLE. 11. DEVICE PLATES A. DEVICE PLATES SHALL BE STAINLESS STEEL UNLESS OTHERWISE NOTED. COMPARABLE EQUIPMENT AS MANUFACTURED BY SIERRA ELECTRIC CORPORATION, HARVEY HUBBLE INC., BRYANT AND LEVITON WILL BE ACCEPTABLE. 12. DISCONNECT SWITCHES A. FURNISH AND INSTALL DISCONNECT SWITCHES AS REQUIRED BY CODE. DISCONNECT SWITCHES SHALL BE NEMA HEAVY DUTY TYPE AND UNDERWRITERS LABORATORIES LISTED, MANUFACTURED BY SQUARE D CORPORATION, ITE, GE, OR WESTINGHOUSE. 13. GROUNDING A. CONTRACTOR SHALL INSTALL A SYSTEM GROUNDING SYSTEM AND AN EQUIPMENT GROUNDING SYSTEM AND SHALL USE ONLY APPROVED GROUNDING CLAMPS AND CONNECTORS AS MANUFACTURED BY PENN - UNION, BURNDY, OR O -Z MFG. COMPANY. B. THE SYSTEM GROUNDING SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND THE UTILITY COMPANY REGULATIONS. CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTORS TO THE NEUTRAL BAR INSIDE THE MAIN PANEL. WHEN TRANSFORMERS ARE USED TO PROVIDE A SEPARATELY DERIVED SYSTEM, THE CONTRACTOR SHALL CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL BAR INSIDE THE SECONDARY SYSTEM PANEL OR SERVICE RATED DISCONNECT SWITCH, DO NOT CONNECT THE GROUNDING ELECTRODE CONDUCTOR TO THE NEUTRAL LUG INSIDE THE TRANSFORMER. C. THE EQUIPMENT GROUNDING SYSTEM SHALL CONSIST OF A CONTINUOUS CONDUIT INSTALLATION AND A GREEN INSULATED EQUIPMENT GROUNDING CONDUCTOR. THIS GROUNDING CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT OR RACEWAY WITH THE FEEDER OR BRANCH CIRCUIT CONDUCTORS. THIS GROUNDING SHALL BE EXTENDED FROM THE HOUSING OF EVERY ELECTRICAL LOAD, THROUGH PANELBOARD STATIC GROUNDING BUSSES, TO THE STATIC GROUNDING BUS IN THE MAIN PANEL. THE GROUNDING BUS SHALL BE BONDED TO THE GROUNDED NEUTRAL BAR INSIDE THE MAIN PANEL. 14. UGHTING FIXTURES A. ALL UGHTING FIXTURES AND LAMPS SHALL BE FURNISHED BY OWNER, UNLESS NOTED OTHERWISE. THIS CONTRACTOR SHALL INSTALL LIGHTING FIXTURES AND LAMPS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED BELOW, COMPLETE WITH HANGERS, PLASTER FRAMES AND ALL OTHER NECESSARY ACCESSORIES. B. ALL BALLAST, STARTERS AND LAMPHOLDERS IN FLUORESCENT LIGHTING EQUIPMENT ARE TO BE ELECTRICAL TESTING LABORATORIES, UNDERWRITERS LABORATORIES AND CERTIFIED BALLAST MANUFACTURERS APPROVED. ALL BALLAST FOR FLUORESCENT FIXTURES SHALL BE OF THE HIGH POWER FACTOR TYPE AND SHALL BE GENERAL ELECTRIC "MAXI -MISER II" OR ADVANCED MARK III. WHERE OCTRON LAMPS ARE SPECIFIED PROVIDE APPROPRIATE BALLASTS. C. THIS CONTRACTOR SHALL VERIFY THE FINAL CEILING AND FINISH SCHEDULES TO INSURE THE PROPER INSTALLATION AND MOUNTING OF FIXTURES AND SHALL COORDINATE BEFORE MAKING SUBMITTALS. 15. TELEPHONE SERVICE A. THIS CONTRACTOR SHALL INSTALL A TELEPHONE SERVICE CONDUIT AS SHOWN ON THE DRAWINGS AND FURNISH AND INSTALL (1) 2' X 2' X 3/4" PLYWOOD PANEL MOUNTED ON THE WALL AT LOCATION SHOWN ON PLANS. 16. ,SURFACE METAL RACEWAY A. SURFACE METAL RACEWAY SHALL BE TWO PIECE #2100 AS MANUFACTURED BY WIREMOLD. ALL NECESSARY ACCESSORIES REQUIRED TO FIT THE CONFIGURATION SHOWN SHALL BE PROVIDED. RECEPTACLES SHALL BE 120 VAC, 23 APMS, CATALOG NUMBER #2127GT. 17. TRANSFORMERS A. DRY -TYPE TRANSFORMERS SHALL BE OF THE ENCLOSED VENTILATED TYPE WITH KVA AND VOLTAGE RATING AS CALLED FOR ON THE DRAWINGS AND WITH 150' CLASS H INSULATION AND MINIMUM OF SIX STANDARD FULL CAPACITY TAPS. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE KORFUND OR EQUAL VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. (MOUNT TRANSFORMER ON VIBRATION ISOLATORS). LOCATE TRANSFORMER AS NOT TO CAUSE SERVICING OR CLEARANCE DIFFICULTIES OF VIOLATIONS WITH OTHER EQUIPMENT. B. COMPARABLE EQUIPMENT AS MANUFACTURED BY SQUARE D CORPORATION OR GENERAL ELECTRIC 18. T1MECLOCK$ A. TIMECLOCKS SHALL BE 24 HOUR, 7 DAY , DAY SKIPPER TYPE AS MANUFACTURED BY TORK, INTERMATIC, OR PARAGON. B. E.C. IS TO SET TIMECLOCK TO THE MALL OPERATING HOURS. END OF DIVISION 16 ELO8 319 L RECEIVED APR 222 PERMIT CENTER 5 K 8 8 Ay- I -pJ Iap; T- CO w w 0 U LL U w Cl_ E103