Loading...
HomeMy WebLinkAboutPermit EL08-0328 - WESTFIELD SOUTHCENTER MALL - ZUMIEZZUMIEZ 2646 SC MALL 07 -23 -08 ELO8-3 28 City1if Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206- 431 -3670 Fax: 206- 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2646 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -328 Issue Date: 04/18/2008 Permit Expires On: 10/15/2008 Tenant: Name: ZUMIEZ Address: 2646 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: DAVID MURPHY Phone: 206 341 -9875 Address: 2101 9 AV #211 , SEATTLE WA Contractor: Name: J C ELECTRIC INC Address: 118 NW 184 ST , RIDGEFIELD WA Contractor License No: JCELEI *043N7 Phone: 360 - 887 -7889 Expiration Date: 08/27/2008 DESCRIPTION OF WORK: ELECTRICAL FOR NEW TENANT IMPROVEMENT TO INCLUDE CASEWORK, LIGHTING, AND STORE FRONT. Value of Electrical: $30,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $717.50 2005 Date: Li— g` Q 8 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether ecified herein or not. The granting of this permit d• _ • •t presume • »' a authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf • of work. thorized to sign and obtain this electrical permit. Signature: Print Name: J CaA \v\A.tyrt Date: `t 1(6(0.Y) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -328 Printed: 04 -18 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2646 SOUTHCENTER MALL TUKW Suite No: Tenant: ZUMIEZ Permit Number: EL08 -328 Status: ISSUED Applied Date: 03/28/2008 Issue Date: 04/18/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to • ' e authority to violate or cancel the provision of any other work or local laws regulating construction or the performan ,ork. Signature: Print Name: Jon Csx.A Date: doc: Cond -Elec EL08 -328 Printed: 04 -18 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto: //www. ci. tkwila. wa. us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: z ,c0011-1 LEiJTI M/ L Tenant Name: 7■_)M King Co Assessor's Tax No.: h _ (4Z 0 - 00 I Suite Number: Ve410 Floor: 7 New Tenant: ,Ej Yes ❑ ..No Property Owners Name: V\i r;TT i I LA C OR ror ATI c Mailing Address: I I , 0 1 1N11_ -1-1- LT- g 912rir Clam t L.-PS 1 (A 170 2 5 City State Zip Name: DAJ iD AAQiz,P}- -' Day Telephone: (2ote- .) S.1\ —o'ie s- Mailing Address: Z C 1 ci . Avg l I $I P-ti_l WA 1$ Ia.) City State Zip E -Mail Address: jMJf 1419 o ,norpl- ) J re , ( ors Fax Number: (-2C.6' fit- -II - `.1 I q-q ELECTRI+ Company Name: 4:1) Mailing Address: city Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ ;0 1 000 Scope of Work (please provide detailed information): 14-E,u,' 101 Slc Talk-MT lA.tpgcN5- i'A E KI T I1/44 40 vth r e NTF - ( l z t / . iy S P A t e ' — vv CA4Fta r-et4 < L 16-H't1 IdG 51-C1 cN1" µpc44Mf t CAL AINto Et Ee'TQaL- Will service be altered? ❑ Yes (j No Adding more than 50 amps? ❑ Yes Type of Use: Fe -mil- Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel Dit Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: tg Puget Sound Energy ❑ Seattle City Light H3ApplicationsTorms- Applications On Lineal -2007 - Electrical Permit AppIication.doc bh Page 1 of 2 • • • RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $ I0.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ 'Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable causc demonstrated. 1 1IEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED 'I'HIS APPLICATION AND KNOW II IE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TIIE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O. ELECTRICAL CONT t CTOR: E. FIT Signature: , ` Print Name: (P 2 / IJ(PTSV1yto-Ca Day Telephone: AV 34 1 - l el G Mailing Address: Date: 1 "2e'- v'17 ,2-(c. I H ► Weird t•& e:01 rg 2r ► rn.E , w P i 2 City Slate Zip IDate Application Accepted: VI_ ��1ry+licniinnr4nmx- Applicalinnk nn Lux .1-21)10 - Circuital I'ennn Appllcafnn.J,M hh Date Application Expires: 01. l 0 t GI) Staff Initials: Page 2or2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -328 Address: 2646 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 03/28/2008 Applicant: ZUMIEZ Issue Date: Receipt No.: R08 -01233 Initials: WER User ID: 1655 Payment Amount: $574.00 Payment Date: 04/18/2008 01:32 PM Balance: $0.00 Payee: j C ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1647 574.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 574.00 Total: $574.00 1319 04/18 9711 TOTAL 574.00 rtor: Rar.eint -(1R Printatt• 04- 1R -7(N)R City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -00957 Initials: JEM Payment Date: 03/28/2008 User ID: 1165 Payee: MURPHY VAREY, P.S. Total Payment: 312.03 SET ID: S000000989 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08- 157 57.53 ;. , EL08:;d3218 143.50 M08 -094 79.00 PG08 -097 32.00 TOTAL: 312.03 TRANSACTION LIST: Type Method Description Amount Payment Check 12013 312.03 TOTAL: 312.03 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 143.50 000/345.830 168.53 TOTAL: 312.03 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0 6A-3a Project: / ZJ�1LZ.• Type of Inspection: . /co N.1 Address: l 4 (9 _ d , ,i , ' �'�V Date Called: Special Instructions: Date Wanted: 7 z a.m. P.m Requester: Phone No: ElApproved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: 6,),A Inspector: j;1 6644K Date: cri fr 3 b' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD ,� fig. Retain a copy with permit O INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION /2' 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f 7 ZProject: 1 t e i— Type of Inspection: / oO 5Td Sic Address: y G Lt G ' �vv Date Called: FJ*t.. KWPfisir, rice 1 Pc r> it ,.. Special Instructions: Date Wanted: 2 3 7/e a.m Requester: Phone No: I- DApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: Yti- 5Td Sic FJ*t.. KWPfisir, rice 1 Pc r> it , f P2imd a ( (A 1 t.F'ri mi - SJRv• si for Rckdia togov6 Lo V p Inspector: ..Sti6ovi)6is 'Date: 07/73/A, ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit 16 I•1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION M" 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7 INSPECTION NO. Project: Zdfl 1ei_ Type of Inspection:_ 700 Address: Z4) 4 GI � j _ - _ �"^{� Date Called: Special Instructions: Date Wanted: 1(24 . . Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ctflusv'� Ko y q N 14 Inspector: -del 17Jt/tl\ (Date: 01 /i El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION II- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ZV- A 'CZ' P'� Type of Inspection: 700 3 Address: ��,/� Date Called: Special Instructions: Date Wanted: 71 (1 ]„ AY Requester: Phone No: 0 Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Inspector: •i-Pi &Welk El $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 07/A74 l Receipt No.: IDate: - _. _ - -- - - - INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Zdki 16Z- Type of Inspection: lfoi- Address: 2( 94 ! miitti. Date Called: Special Instructions: Date Wanted: Ik' p.m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: D .14 , v 5tedicA6 • Inspector: Jr &dal Date: 17� fp o ❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #1.00, Tukwila, WA 98188 (206)431 -3670 61,0Y-3A Project: z ti ti I Ez Type of Inspection: 7A�3 W Address: 2 (0 WO el m. Date Called: Special Instructions: Date Wanted: 5,7z...0 p.m. Requester: Phone No: 0 Approved per applicable codes. Ei Corrections required prior to approval. gm COMMENTS: u wm,t/ ciAck Inspector: aTi 664A/cc Date: 05/244 Ej $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -328 PROJECT NAME: ZUMIEZ DATE: 03 -28 -08 SITE ADDRESS: 2646 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: �jEN 4,11-06 Buirding Division Lk Public Works Fire Prevention Structural n Planning Division nPermit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04-01-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04-29-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Electric or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License JCELEI *043N7 Licensee Name J C ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601731772 Ind. Ins. Account Id AGENT Business Type CORPORATION Address 1 118 NW 184TH ST Address 2 City RIDGEFIELD County CLARK State WA Zip 98642 Phone 3608877889 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 8/27/1996 Expiration Date 8/27/2008 Suspend Date Separation Date Parent Company Previous License JCELE * *055JD Next License Associated License COULIJN976NK Master Electrician Information License COULIJN976NK Name COULIMORE, JON N Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date COULIMORE, JON 01/01/1980 COULIMORE, JON AGENT 01/01/1980 Bond Information 1 Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License = JCELEI *043N7 04/18/2008 TO CIRCUIT BREAKER 13-19 TO CIRCUIT BREAKER 13-21 TO CIRCUIT BREAKER B -23 TO CIRCUIT BREAKER B -25 (16.100)SWITCH BANK SEPARATE PERMIT REQUIRED FOR: eiMethanical Plumbing liGas Piping City of Tukwila BUILDING DIVISION TO SWITCH Se TO SWITCH Sf TO SWITCH Sg TO SWITCH Sh CONTRACTOR TO PROVIDE "BULLET SERIES" CURRENT UMIIING PANEL BY LIGHTING CONTROL AND DESIGN, INC. (323) 226 -0000 www.lightingcontrols.com. MODEL #T24 -6 —SM. CURRENT LIMITING PANEL N.T.S. LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CATALOG NUMBER VOLTS WATTS LAMP ORDER NUMBER QTY DESCRIPTION NOTES A B HUBBELL JUNO SWD- 175— El —AP —WH 120 218 175W MN 1 PENDANT 4,5 #R731 BL, 20, #R23, 11. 34, BLACK 120 50 50W MR16 /NSP 1 TRACK LIGHTING 4,5 C RESOLUTE #3619 —TOR 120 40 40W —A19 —CLEAR 1 PENDANT 1,4 D JUNO #133BL /T30713L 120 50 50W PAR30 NSP 1 TRACK LIGHTING 4,5 01 JUNO #133BL/T307BL 120 50 50W PAR30 NFL 1 TRACK LIGHTING 4,5 H RESOLUTE #3629 —TOR 120 40 40W —A19 —CLEAR 1 PENDANT 1,4 LITHONIA C- 2- 32- 120 —GEB 120 76 F032/741 2 CHAIN HUNG 2,3,4 IE LITHONIA C -2 -32- 120— GEB —EL 120 76 F032/741 2 CHAIN HUNG J UGHTOLIER 478BKX -40ZR1 C9X 120 50 50W MR16 FL 1 RECESSED • 2,3,4 4,5 K LITHONIA WC -2 -17- 120 —TUBI 120 30 F017/741 2 VANITY 4,5 L LITHONIA 6ELM2P 120 15 INCL W /FIXTURE 2 EMERGENCY 2,4 X LITHONIA LQM— S- 1— R- 120/277 —EL 120 5 LED W/FIXTURE 1 EXIT LIGHT 2,4 LIGHTING NOTES 1. FIXTURE PROVIDED BY OWNER, INSTALLED BY ELECTRICAL CONTRACTOR. 2. FIXTURE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 3. PROVIDE SEISMIC BRACING AS NEEDED FOR CHAIN HUNG FIXTURES. 4. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOUNTING HARDWARE AS REQUIRED. 5. FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR. ROUTE VIA TO Sd TIMECLOCK 1H IN ROUTE VIA 11MECLOCK /H IN CONTACTOR #1 WINDOW LTS DISPLAY LTS -- 0-1 1--0 —• B -18 1---0 + 13--16 H H CONTACTOR #2 SIGNAGE - 0 WINDOW 4--- -0 I RECEPTS WINDOW .1-0 RECEPTS CONTRACTOR TO PROVIDE ENCLOSURE FOR CONTACTORS CONTACTOR DETAIL N.T.S. 16.104) REF ARCH FOR FIXTURE QUANTITIES AND LOCATIONS REF ARCH FOR FIXTURE QUANTITIES AND LOCATIONS Ka B-4 ®1YP B -4 B-4 DIVIDE 86 LIGHTS EVENLY BETWEEN FOUR CIRCUITS. ROUTE VIA CLP REF 4/E1. 21 25 FILE C Ply PM* NO. • Pint^ review approval is subject to errors and not Approval of �_ the violation of any ad .r1/*!`� :. r . Receipt of approved Reid ...✓ - ay Date: City of Tu BUILDING DIVISION REVISIONS No changes shalt be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. i • B -4 r-- -- — T — — -- -- — - ago-- - - - - -- ELECTRICAL SYMBOLS LEGEND LIGHTING KEYNOTES (SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS) SYMBOL DESCRIPTION EXIT FIXTURE (WALL MOUNTED /CEILING MOUNTED) 1=?" EMERGENCY LIGHT $ SWITCH, SINGLE POLE SOS SWITCH, OCCUPANCY SENSOR RECEPTACLE, DUPLEX ❑ � RECEPTACLE, QUADRUPLEX NON—FUSED DISCONNECT SURFACE MOUNTED PANELBOARD Y TELEPHONE /DATA O SPEAKER MOTOR NEU1RA IAID CIRCUIT, CONCEALED WHERE H0 POSSIBLE, E INDICATES EXISTING c WIRING ABBREVIA11ONS EF GFI WH AFF TYP EXHAUST FAN GROUND FAULT CIRCUIT INTERRUPTER WATER HEATER ABOVE FINISHED FLOOR TYPICAL 16.100 NEW SWITCHBANK. PROVIDE A LIGHTING SWITCH FOR EACH UGHTING CIRCUIT AND AS REQUIRED. ENGRAVE EACH COVER PLATE AS FOLLOWS: SALES LTG., D.R. LTG., CASEWORK LTG., CASH WRAP LTG., DISPLAY WINDOW TRACK LTG., STOREFRONT LTG., SALES TRACK LTG., SEE SWITCH BANK DETAIL 16.101 NEON SIGN, COORDINATE ELECTRICAL CONNECTION REQUIREMENTS WITH OWNER AND LANDLORD. ROUTE THROUGH 11MECLOCK. 16.102 PROVIDE WIREWAY AT +12' -0" AFF. USE GRAY COLOR WIREMOLD ODS3(G3000) WITH DUPLEX RECEPTACLES ON 3' -0" CENTERS. PROVIDE ALL HARDWARE AND HANGERS. ALTERNATE BRANCH CIRCUIT TO RECEPTACLES THROUGHOUT. 16.103 STORE FRONT SIGN: PROVIDE AND INSTALL DISCONNECT IN CEILING SPACE. COORDINATE LOCATION WITH SIGN INSTALLER. 16.104 INSTALL QUANTITY OF LIGHT FIXTURES AS INDICATED ON ARCHITECTURAL DRAWINGS. INSTALL FIXTURES ALONG ENURE LENGTH OF RACEWAY AS DIRECTED. PROVIDE MATERIALS AS REQUIRED. SEE ARCHITECTURAL DRAWINGS FOR SUSPENDED LIGHT AND PIPE HANGER DETAILS. 16.105 INSTALL OWNER FURNISHED SPEAKERS. PENDANT MOUNT AT +13' —O" AFF COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH —IN. PROVIDE LOOPED OR SERIES WIRING PLAN WITH 14 GAUGE PLENUM RATED SPEAKER WIRE HIDDEN BEHIND THE DRYWALL. PROVIDE 10' MINIMUM SPARE CABLE COILED AT CASH WRAP FOR FINAL STEREO SYSTEM TERMINATIONS. PROVIDEFINAL CONNECTION TO SPEAKERS AND SOUND SYSTEM AS REQUIRED. 16.106 ROUTE CONDUIT CONCEALED UP TO STRUCTURE. ROUTE TIGHT TO THE UNDERSIDE OF STRUCTURE TO PANELBOARD. GEN. DEMOLITION NOTES B6 B8 B14 B6 O 0 0 0 0 0 0 0 O 0 0 0 Sa Sb Sc Sd B19 B21 B23 B25 O 0 0 0 0 0 0 0 O 0 0 0 Se Sf Sg Sh PROVIDE SWITCH LABELS, PER ARCHITECTURAL kEVIENNED cCNFPA70_NEC PR -3 08 SWITCHBANK DETAIL N.T.S. 16.106 16.102) B -4 NL am) B -4 NIGHT LIGHT FIXTURE, NL, PROVIDE HOT UNSWITCHED CONDUCTOR, TYP PROVIDE LEUTRON OCCUPANCY SENSOR WITH NO MORE THAN 30 MIN SETIING. SWITCH VANITY LIGHT WITH M0110N SENSOR IN EXHAUST FAN. MOUNT FIXTURES IN STOCKROOM AND CORRIDOR +12' -0 ", TYP—\ ..1 B -4 4 ? 16.105)TYP OF SPEAKERS B-4 !._ +13' AFF, TYP OF SALES AREA LIGHTING PLAN 1/4" — 1'--0" NL 1. REMOVE ALL EXISTING ELECTRICAL BRANCH CIRCUIT WIRING, EQUIPMENT AND DEVICES UNLESS NOTED OTHERWISE. LIGHTING GENERAL NOTES 1. ELECTRICAL CONTRACTOR SHALL COMMISION AND DEMONSTRATE LIGHTING CONTROL SYSTEM FOR STORE PERSONNEL SCHEDULE WITH STORE MANAGER WHEN DEMONSTRATION SHALL TAKE PLACE. 2. COORDINATE WITH ARCHITECTUAL DRAWINGS FOR EXACT LOCATION AND QUANTITY OF LIGHT FIXTURES. CONDUIT/ WIRING NOTES 1. AC CABLING, MC CABLING, AND NONMETAWC SHEATHED CABLING ARE NOT ALLOWED. 2. FLEXIBLE CONDUIT IS NOT ALLOWED, EXCEPT FOR WHIP (LESS THAN 6 FEET IN LENGTH), CONNECTION TO MOTORS, TRANSFORMERS, AND OTHER EQUIPMENT THAT PRODUCES VIBRATIONS. USE ONLY GALVANIZED STEEL FLEX. T 8-4 B -4 14 8 18 • • B 22 18 • • • (16.101) (16.103 MOUNT TO INTERMEDIATE WINDOW FRAME (TYP) 0 wmmz SOUTHCENTER MALL SPACE # 2115 633 Soumerara Swarm, WA 98188 MURPHY V[1i EYps DAVID I. MURPHY, AIA UM NB= AMU &MIsu 97 4171.1, YllEDICION 9Se 1 T: so6.3g. g8 F: so66.3g.9rfl Se vvw. Mminaurr.com Harrison French and Associates 809 S.W. "A" Street Bentonville, AR 72712 (479) 273 -7780 fax (479) 273 -9436 EXPIRES: 07/22/08 PROJECT NUMBER: 05-08-02008 ZUMIEZ STORE NUMBER: 19 ISSUED FOR: PRELIMINARY MALL REVIEW DATE: 02 -08 -08 PRELIMINARY MALL REVIEW RECEIVED CITY OF TUI:VVILA MAR 2 8 2008 PERMIT CENTER EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMIUARIZE WORKERS WITH THIS KNOWLEDGE. —21gs SHEET TITLE: LIGHTING PLAN SHEET NUMBER: E1 (16.135) 2" CONDUIT AND 200A FEEDER PROVIDED AND INSTALLED BY LANDLORD. MAIN DISCONNECT PROVIDED BY LANDLORD. 2 "C,4#3/0,1 #6GR 3/4 "C,3#8, 1#10 GR PANEL A TENANT SPACE 30KVA XFMR TIMECLOCK SCHEDULE LABEL AS SHOWN NO. LOAD SERVED MANUFACTURER CATALOG NO. MOTOR VOLTS CCT. NO. CONTACT INITIAL TIME SETTING NOTES TS1 STOREFRONT SIGN STOREFRONT UGHTS WINDOW RECEPTS TORK W300L 120V 3P 40A 120V 3PST INDOOR, 7 DAY,24HR NOTES: 1,2,3 NOTES: 1. INDICATED SWITCH SHALL BE HEAVY DUTY TYPE. 2. FURNISH AND INSTALL DISCONNECT SWITCHES WITH DUAL ELEMENT, 3. TIME DELAY FUSES AS EQUIPMENT MANUFACTURER REQUIRES. SUSPEND XFMR ABOVE 1 - 1 1/4"C, 4#3,1 #8GR,1 #8 IG IBOND#8CU TO BUILDING STEEL PER NEC PANEL B ONE -UNE KEYED NOTES: NEW 200A 277/480V, 3PHASE PANEL TO BE PROVIDED AS SCHEDULED. NEW 30KVA TRANSFORMER TO BE SUSPENDED FROM STRUCTURE AS SHOWN. NEW TIME CLOCK PROVIDED BY ELECTRICAL CONTRACTOR. NEW CONTACTOR ENCLOSURE REF 3/E1. NEW CURRENT LIMITING PANEL REF 4/E1. NEW 100A 120/208V, 3PHASE PANEL TO BE PROVIDED AS SCHEDULED. NOTE ALL EQUIPMENT IS NEW TO BE PROVIDED BY ELECTRICAL CONTRACTOR AS SHOWN, UNLESS NOTED OTHERWISE. • ONE -LINE DIAGRAM N.T.S. NEW PHONE BOARD 16.125 l 0 USH- BUTTON, +48" AFF I.1 5 PANEL A PANEL B B L_ TRANSFORMER TB SUSPENDED ABOVE A• HI 2 J COORDINATE CONNECTION OF NEW VAV WITH MECHANICAL 1 A SERVES: DISTRIBUTION LOCATION: CORRIDOR NEW PANELBOARD 200A MAIN LUG ONLY 3PH 4WIRE 480/277V GROUND BAR CK LOAD SERVED WIRE BRKR PL PHASE A PHASE B PHASE C PL BRKR WIRE LOAD SERVED 1 TRANSFORMER TB 8 50 3 6.26 1 5.00 5.47 1 5.00 4.86 1 5.00 7 9 11 13 15 17 SPACE 0.00 1 0.00 SPACE SPACE 0.00 1 0.00 3 25 10 VAV1 2 4 6 SPACE 8 SPACE 10 SPACE 0.00 1 0.00 0.00 I o.00 SPACE 12 SPACE SPACE o.00 1 o.00 SPACE 14 SPACE 16 0.00 1 0.00 SPACE 18 PER NEC ARTICLE 220 TOTAL TOTAL LOAD FEEDER LOAD 11.26 40.65 31.59 33.04 10.47 9.86 37.79 35.60 KVA KVA 38.04 39.78 KVA AMPS AMPS AMPS (L) INDICATES LOCKING DEVICE B ( 100A MAIN LUG ONLY SERVES: DISTRIBUTION NEW PANELBOARD PHFZ€- ZQB/f2w LOCATION: CORRIDOR GROUND BAR ISOLATED GROUND BAR CK LOAD SERVED WIRE BRKR PL PHASE A PHASE B PHASE C PL BRKR WIRE LOAD SERVED CK 1 STOCK RECEPTS 12 20 1 0.54 1 0.49 31.59 N.E.C. DEMAND 1 20 12 STOCKROOM LTS 2 3 SALES RECEPTS 12 20 1 7.24 0.72 0.43 1 20 12 EMER /EXIT /NL (L) 4 5 WINDOW RECEPTS 12 20 1 0.72 1 0.18 1 20 12 11MECLOCK /CONY. 6 7 WINDOW RECEPTS 12 20 1 0.72 1 1.31 1 20 12 SALES LTS 8 9 SALES RECEPTS 12 20 1 0.54 1 0.12 1 20 12 DRESSING RM LTS 10 11 SALES RECEPTS 12 20 1 0.36 1 0.00 1 20 -- SPARE 12 13 CASHWRAP IG 12 20 1 0.36 1 0.44 1 20 12 CASHWRAP LTS 14 15 CASHWRAP 12 20 1 0.36 T CCI 1 20 12 STOREFRONT LTS 16 17 WATER HEATER (L) 12 20 1 1.50 1 0.90 1 20 12 DISPLAY LTS 18 19 PLUGMOLD SALES 12 20 1 1.20 1 0.00 1 20 -- SPARE 20 21 PLUGMOLD SALES 12 20 1 1.20 1 1.20 1 20 12 SIGNAGE 22 23 PLUGMOLD SALES 12 20 1 1.20 1 0.00 1 20 -- SPARE 24 25 PLUGMOLD SALES 12 20 1 1.20 1 0.00 1 20 --- SPARE 26 27 SPARE -- 20 1 0.00 0.00 1 20 --- SPARE 28 29 SPARE -- 20 1 0.00 1 0.00 1 20 -- SPARE 30 31 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 32 33 SPARE -- 20 1 0.00 1 0.00 1 20 -- SPARE 34 35 SPARE -- 20 1 0.00 1 0.00 1 20 -- SPARE 36 37 SPARE -- 20 1 0.00 0.00 1 20 -- SPARE 38 39 SPARE -- 20 1 0.00 1 0.00 1 20 -- SPARE 40 41 SPARE -- 20 1 0.00 1 0.00 1 20 -- SPARE 42 TOTAL TOTAL LOAD PER NEC ARTICLE 220 FEEDER LOAD 6.26 5.17 4.86 KVA AMPS AMPS AMPS (L) INDICATES LOCKING DEVICE 52.17 43.08 40.50 16.29 KVA KVA 45.27 17.66 49.08 LOW VOLTAGE GEN. NOTES POWER KEYNOTES 1. ALL LOW VOLTAGE WIRING SHALL BE ROUTED IN CONDUIT. GEN. DEMOLITION NOTES 1. REMOVE ALL EXISTING ELECTRICAL BRANCH CIRCUIT WIRING, EQUIPMENT AND DEVICES UNLESS NOTED OTHERWISE CONDUIT/ WIRING NOTES 1. AC CABLING, MC CABUNG, AND NONMETAWC SHEATHED CABLING ARE NOT ALLOWED. 2. FLEXIBLE CONDUIT IS NOT ALLOWED, EXCEPT FOR WHIP (LESS THAN 6 FEET IN LENGTH), CONNECTION TO MOTORS, TRANSFORMERS, AND OTHER EQUIPMENT THAT PRODUCES VIBRATIONS. USE ONLY GALVANIZED S Il±L FLEX. CONNECTED LOADS LOAD LIGHTS RCEPT. RCEPT. REFRIG. KITCHEN MISC. NI HVAC TOTAL CONNECTED LOAD (KVA) 5.79 9.12 0.00 0.00 0.00 0.18 1.50 15.00 31.59 N.E.C. DEMAND 125% 100% 50% 100% 65% 100% 100% 100% FEEDER LOAD (KVA) 7.24 9.12 0.00 0.00 0.00 0.18 1.50 15.00 33.04 WH, MOUNT ABOVE CEILING, COORDINATE LOCA11ON WITH PLUMBING 16.121 SURFACE MOUNTED JUNCTION BOX FOR HARD -WIRED CASEWORK IGHT FIXTURE. COORDINATE EXACT LOCATION WITH ARCHITECT. PROVIDE WALL SWITCH AT SWITCH BANK LOCATION FOR ON /OFF CONTROL OF LIGHT FIXTURE NOTED. RUN ALL ASSOCIATED CONDUIT SURFACE MOUNTED ON FLOOR BENEATH CASEWORK. WIRE LIGHT FIXTURE F.B.O.I.C. 16.123 POKE - THROUGH LOCATION INDICATED IS DIAGRAMMATIC. LOCATE POKE - THROUGH DEVICE BENEATH CASEWORK. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO COMMENCEMENT OF WORK. 16.124 PROVIDE DUPLEX RECEPTACLE IN WINDOW BASE. CONCEAL CONDUIT IN WINDOW BASE. PROVIDE BLACK OUTLET WITH BLACK COVERPLATE ROUTE POWER THROUGH TIMECLOCK. TYPICAL AT DISPLAY WINDOWS UNLESS NOTED OTHERWISE. 16.125 NEW TELEPHONE TERMINAL BOARD. INSTALL 4'X4'X3/4" FIRE TREATED PLYWOOD BACKBOARD WITH #6 CU GND. WIRE TO NEAREST BUILDING GROUND ELECTRODE. COORDINATE INSTALL WITH LANDLORD. 16.127 PROVIDE EDWARDS MINIATURE LUNGEN 115 SERIES BUZZER IN CASHWRAP. PROVIDE BUZZER, TRANSFORMER, PUSHBUTTON, CONDUCTORS, AND ALL CONNECTIONS REQUIRED FOR A COMPLETE FUNCTIONAL SYSTEM. RUN LOW VOLTAGE WIRING, CONCEALED IN CLG. SPACE OR IN WALL CAVITY, BACK TO DOOR PUSHBUTTON. 16.130 PROVIDE DUPLEX RECEPTACLE MOUNTED TO SOFFIT ABOVE DISPLAY WINDOW. COORDINATE EXACT LOCA11ON WITH ARCHITECT PRIOR TO INSTALLATION. ROUTE POWER THROUGH 11MECLOCK. 16.131 RUN (2) 1" CONDUITS OVERHEAD TIGHT TO UNDERSIDE OF STRUCTURE. EXTEND CONDUITS TO TELEPHONE TERMINAL BOARD. SEE " CASHWRAP" DETAIL 16.134 1" CONDUIT STUB TO CEILING SPACE FOR VIDEO, STEREO, AND CHIME LV. CABLE TO CASEWORK, VERIFY LOCATION PRIOR TO ROUGH IN. 16.135 ILLUMINATED BUZZER PUSH - BUTTON AT +48" AFF WITH W C. STUB TO CEILING SPACE. LABEL BUZZER "ZUMIEZ" WITH PLASTIC SIGN. REVIEWED LIAANCE CODE COMPLIANCE 70 - NEC APR - 3 20ra$ Tukwila BUILD NG DIVISION -r1111111 ALL UNDERGROUND CONDUITS TO BE 1" I I I I (16.131) ROUTE ALL CONDUITS (16.134) FOR CASH WRAP IN (16.123 CABINET, TYP OF 5 (16.127, Q CASH WRAP SWITCH CASE LIGHTS WITH PENDANT UGHTING ABOVE. SWITCHED JUNCTION 16.121 BOX FOR CASE LIGHTING 111 ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE, OPERATIONAL FIRE ALARM SYSTEM IN ACCORDANCE WITH ALL CODE AND MANUFACTURING REQUIREMENTS, INCLUDING DEVICES REQUIRED BY LOCAL AHJ AND MALL FINAL CONNECTION FROM THE TENANT'S FIRE ALARM SYSTEM TO THE MALL'S FIRE ALARM SYSTEM WILL BE BY LANDLORD'S CONTRACTOR AT TENANTS EXPENSE. POWER PLAN 1 /4" = 1'--0" 16.130 COORDINATE LOCATION WITH OWNER, TYP OF 4 16.130 WIN 16.124 16.124 ■R IR RR 1f, Is IR EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBIUTY OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMIUARIZE WORKERS WITH THIS KNOWLEDGE. zumez SOUTHCENTER MALL SPACE ft 2115 633 S017111001TER SEATr,la, WA 98188 MURPHY VAREYPs DAVID J. MURPHY, AIA um riu=Amax Brian Bums, Tomas* 95= T: 106.541.9875 F: sa6.5P • 9ry E: vvv. MvascYAl �i Harrison French and Associates 809 S.W. "A" Street Bentonville, AR 72712 (479) 273 -7780 fax (479) 273 -9436 EXPIRES: 07/22/08 ,ce RECEIVED CITY OF TUKWILA MAR 2 81008 PERMIT CENTER PROJECT NUMBER: 05 -08 -02008 ZUMIEZ STORE NUMBER: 19 ISSUED FOR: PRELIMINARY MALL REVIEW DATE: 02 -08 -08 PRELIMINARY MALL REVIEW SHEET TITLE: POWER PLAN SHEET NUMBER: E2 FLOOR Project Address ZUMIEZ- SOUTHCENTER MALL Date 3/10/2008 The follow ing information is necessary to check a fighting permit application for compliance w ith the lighting requirements in the 2004 Washington State Nonresidential Energy Code, Applicability (yes, no, n.a.) Code Section Component Information Required Location Building Department on Flans Notes LIGHTING CONTROLS (Section 1513) no Yes n. a. n. a. n. a. yes n. a. n.a. yes yes n. a. 1513.1 1513.2 1513.3 1513.4 1513.6 Local controVaccess Schedule w ith type, indicate locations Area controls Maximum limit per sw itch El Daylight zone control vertical glazing Schedule w ith type and features, indicate locations Indicate vertical glazing on plans overhead glazing Cis play /exhib /special Indicate overhead glazing on plans Indicate separate controls El Exterior shut -off Schedule w ith type and features, indicate location (a) timer w /backup Indicate location (b) photocell. Indicate location Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule w ith type and locations El. 1513.6.2 1513.7 (b) auto. sw itches Schedule w ith type and features (back-up, override capability Indicate size of zone on plans E2 Connissioning Indicate requirements for lighting controls corrrrissioning yes Lighting Sum. Form Completed and attached. Schedule w ith fixture types, lamps, ballasts, w atts per fixture E3 n.a. ® 1437 Bec motor efficiency MECH -MOT or Equipment Schedule w ith hp, rpm, efficiency If "no" is circled for any question, provide explanation: Local lighting control for the retail space lighting is not required per exception #1 of section 1513.1. (2) 1" CONDUITS TO CASHWRAP. (1) FOR DATA /VOICE CABLING AND (1) SPARE. TELE.BKBD ROUTE CONDUITS TIGHT TO UNDERSIDE OF STRUCTURE BELOW. COLUMN /WALL TOE KICK Lighting Summary' Project Info Project Address ZUMIEZ- SOUTHCENTER MALL Date 3/10/2008 Applicant Name: ZUMIE Z Applicant Address: TUKWILA, WA Applicant Phone: For Building Department Use Project Description ❑ New Building ❑ Addition 0 Alteration ['Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Pow er Allow ance 0 Systems Analysis ❑ Gear (See Qualification Checklist (over). Indicate Prescriptive & IPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new , installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage (Interior) Location (floor /room no.) Occupancy Description A flow ed Watts per ft2 Area in ft2 Allowed x Area TENANT SPACE RETAIL 1.50 2668.0 4002.0 STORAGE STORAGE 0.50 467.0 233.5 ** From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts Notes: 1. Use manufacturer's fisted maximum input w attage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights unless less than 5 w atts per fixture. 3. List all fixtures. For exempt lighting. not exception and leave Watts /Fixture blank. Number of Watts / Watts Fixtures Fixture Proposed Proposed Lighting Wattage (Interior) Location (floor /room no.) 4235.5 Fixture Description SALES TYPE A - PENDANT 8 218.0 1744.0 SALES TYPE B - SHOWCASE DISPLAY (EXEMPT) SALES TYPE C - CASH WRAP PENDANT 11 40.0 490.0 SALES TYPE D - PORTABLE PLUG IN DISPLAY (EXERT) SALES TYPE D1 -- PORTABLE PLUG IN DISPLAY (EXEMPT) SALES TYPE H - DRESSING RM PENDANT 3 40.0 120.0 STORAGE TYPE I -- 4 FT STRIP 5 76.0 380.0 CORRIDOR TYPE IE - 4 FT STRIP 2 76.0 152.0 SALES TYPE K -- VANITY LIGHT 1 30.0 30.0 SALES TYPE L - EMERGENCY FIXTURE (EXEMPT) SALES TYPE X - EXIT LIGHT (EXEMPT) Total Proposed Watts may not exceed Total Allow ed Watts for Interior Total Proposed Watts REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR - 3 2008 City flf Tukwila B ILDING D - ION 2866.0 1" CONDUIT STUB TO BOTTOM OF STRUCTURE FOR VIDEO, STEREO AND BUZZER LV. CABLE. STUB TO BENEATH CASEWORK. REG. #1 REG. #2 CASH WRAP DETAIL N.T.S. 1" CONDUIT FOR DATA/VOICE CABLING E 1° DATA CONDUIT 1" VOICE CONDUIT C7-) TYP RECEIVED CITY OF TUKVVILA MAR 2 8 2008 PERMIT CENTER EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. zumez SOUTSCENTER MALL SPACE # 2115 6 $rn acaw e Swarm, WA 98188 MURPHY VYPs DAVID J. MURPHY, AIA uoi Mon draw Gamut BUM; Y1ualCratr glint 7: lo6.S4t•9�lS F: m6.3 . 9117 E: rvv. ]fom:Yaur.aat Harrison French and Associates 809 S.W. "A" Street Bentonville, AR 72712 (479) 273 -7780 fax (479) 273 -9436 EXPIRES: 07/22/08 PROJECT NUMBER: 05.08.02008 ZUMIEZ STORE NUMBER: 19 ISSUED FOR: PRELIMINARY MALL REVI Ew DATE: 02 -08 -08 PRELIMINARY MALL REVIEW SHEET TITLE: ELECTRI CAL DETAILS SHEET NUMBER: E3 CASHWRAP DETAIL GENERAL NOTES 1. DETAIL IS DIAGRAMMATIC. REGISTER LOCATIONS SHOWN ON PLANS MAY DIFFER FROM DETAIL. 2. SEE POWER PLAN FOR CASEWORK LIGHTING ELECTRICAL REQUIREMENTS. 3. SEE POWER PLAN FOR ADDITIONAL INFORMATION. CASHWRAP DETAIL KEYED NOTES 1. PROVIDE JUNCTION BOX BENEATH CASEWORK ACCESS PANEL, ADJACENT TO 4 -PLEX, FOR ROUTING OF NETWORK, DATA, AND TELEPHONE CABLING. 1" CONDUIT STUB TO BOTTOM OF STRUCTURE FOR VIDEO, STEREO AND BUZZER LV. CABLE. STUB TO BENEATH CASEWORK. REG. #1 REG. #2 CASH WRAP DETAIL N.T.S. 1" CONDUIT FOR DATA/VOICE CABLING E 1° DATA CONDUIT 1" VOICE CONDUIT C7-) TYP RECEIVED CITY OF TUKVVILA MAR 2 8 2008 PERMIT CENTER EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH THIS KNOWLEDGE. zumez SOUTSCENTER MALL SPACE # 2115 6 $rn acaw e Swarm, WA 98188 MURPHY VYPs DAVID J. MURPHY, AIA uoi Mon draw Gamut BUM; Y1ualCratr glint 7: lo6.S4t•9�lS F: m6.3 . 9117 E: rvv. ]fom:Yaur.aat Harrison French and Associates 809 S.W. "A" Street Bentonville, AR 72712 (479) 273 -7780 fax (479) 273 -9436 EXPIRES: 07/22/08 PROJECT NUMBER: 05.08.02008 ZUMIEZ STORE NUMBER: 19 ISSUED FOR: PRELIMINARY MALL REVI Ew DATE: 02 -08 -08 PRELIMINARY MALL REVIEW SHEET TITLE: ELECTRI CAL DETAILS SHEET NUMBER: E3 SEC11ON 16A: ELECTRICAL 16A 1 GENERAL INSTRUCTIONS 16A 1 -1 GENERAL REQUIREMENTS ALL REQUIREMENTS UNDER DIVISION 1 AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS APPLY TO THIS SECTION AND DIVISION. WHERE THE REQUIREMENTS OF THIS SECTION AND DIVISION EXCEED THOSE OF DIVISION 1, THIS SECTION AND DIVISION TAKE PRECEDENCE. BECOME THOROUGHLY FAMILIAR WITH ALL THEIR CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION, SEC11ON OR BOTH. WORK REQUIRED UNDER THIS DIVISION INCLUDES ALL MATERIAL, EQUIPMENT, APPUANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY THE DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTIONING AS IMPLIED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE, SHALL BE PROVIDED AS IF DESCRIBED IN BOTH, IN THE EVENT OF DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION PRIOR TO PROCEEDING WITH THE WORK INVOLVED. DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE WORK UPON WHICH THE CONTRACT IS BASED. THEY SHOW THE MATERIALS AND THEIR RELATIONSHIP TO ONE ANOTHER, INCLUDING SIZES, SHAPES, LOCATIONS, AND CONNECTIONS. THEY ALSO CONVEY THE SCOPE OF WORK, INDICATING THE INTENDED GENERAL ARRANGEMENT OF THE EQUIPMENT, FIXTURES, OUTLETS AND CIRCUITS WITHOUT SHOWING ALL OF THE EXACT DETAILS AS TO ELEVATIONS, OFFSETS, CONTROL LINES, AND OTHER INSTALLATION REQUIREMENTS. USE OF THE DRAWINGS AS A GUIDE WHEN LAYING OUT THE WORK AND TO VERIFY THAT MATERIALS AND EQUIPMENT WILL FIT INTO THE DESIGNATED SPACES, AND WHICH, WHEN INSTALLED PER MANUFACTURES' REQUIREMENTS, WILL ENSURE A COMPLETE, COORDINATED, SATISFACTORY AND PROPERLY OPERATING SYSTEM. SPECIFICATIONS DEFINE THE QUALITATIVE REQUIREMENTS FOR PRODUCTS, MATERIALS, AND WORKMANSHIP UPON WHICH THE CONTRACT IS BASED. 16A 1 -2 PRE —BID SITE INSPECTION PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED OF CONDITIONS UNDER WHICH THE WORK I5 TO BE DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 16A 1 -3 MATERIAL AND WORKMANSHIP PROVIDE ALL MATERIAL AND EQUIPMENT NEW AND IN FIRST CLASS CONDITION. PROVIDE MARKINGS OR A NAMEPLATE FOR ALL MATERIAL AND EQUIPMENT IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, PROVIDE COMMERCIAL SPECIFICATION GRADE QUALITY FOR ALL MATERIALS AND EQUIPMENT. UGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE ACCEPTABLE. PROVIDE ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK. STORE AND MAINTAIN MATERIAL AND EQUIPMENT IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. FURNISH ONLY MATERIAL AND EQUIPMENT THAT ARE USTED, LABELED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL), WHENEVER ANY LISTING OR LABELING EXISTS FOR THE TYPES OF MATERIAL AND EQUIPMENT SPECIFIED. 16A 1 -4 COORDINATION COORDINATE ALL WORK WITH OTHER DIVISIONS AND TRADES SO THAT THE VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS ARE INSTALLED AT THE PROPER TIME, FIT THE AVAILABLE SPACE, AND ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. REFER TO ALL DRAWINGS, INCLUDING, BUT NOT UMITED TO, CIVIL, ARCHITECTURAL, 5 TRUCTIRA MECHANICAL AND PLUMBING, AND TO RELEVANT L-, L, , EQUIPMENT SUBMITTALS AND SHOP DRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONCEAUNG RACEWAYS IN THE MANNER ANTICIPATED IN THE DESIGN. PROVIDE MATERIALS MTh TRIM THAT WILL FIT PROPERLY THE TYPES OF CEIUNG, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED. 16A 1 -5 DEFINITIONS WHENEVER USED IN THESE SPECIFICATIONS OR DRAWINGS, THE FOLLOWING TERMS SHALL HAVE THE INDICATED MEANINGS: FURNISH: TO SUPPLY AND DELIVER TO THE PROJECT SITE READY FOR UNLOADING, UNPACKING, ASSEMBLING, INSTAWNG AND SIMILAR OPERATIONS. INSTALL TO PERFORM ALL OPERATIONS AT THE PROJECT SITE, INCLUDING, BUT NOT LIMITED TO, AND AS REQUIRED: UNLOADING, UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, TESTING, COMMISSIONING, STARTING UP AND SIMILAR OPERATIONS, COMPLETE, AND READY FOR THE INTENDED USE." PROVIDE: TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER (OR OWNER— FURNISHED) OR FURNISHED BY OTHERS: "AN ITEM FURNISHED BY THE OWNER OR UNDER OTHER DIVISIONS OR CONTRACTS, AND INSTALLED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR THE INTENDED USE, INCLUDING ALL ITEMS INCIDENTAL TO THE WORK NECESSARY FOR PROPER INSTALLATION AND OPERATION. INCLUDE THE INSTALLATION UNDER THE WARRANTY REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERRED TO IN THIS DIVISION, "ENGINEER" IS THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO THE "ARCHITECT". AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND USTED BY OSHA IN 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. THE TERMS "APPROVED EQUAL ", "EQUIVALENT", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY AN NRTL., AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 16A 1 -6 DIMENSIONS AND LAYOUTS DRAWINGS ARE SCHEMATIC IN NATURE, SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY SHALL BE INTEGRATED WITH OTHER PARTS OF THE WORK. FIGURED DIMENSIONS TAKE PRECEDENCE TO SCALED DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. CORRECT ERRORS THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION, AT NO ADDITIONAL COST TO THE OWNER. 16A 1 -7 ORDINANCES AND CODES COMPLY, AT A MINIMUM, NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES, STATE AND LOCAL BUILDING CODES, AND ALL OTHER APPUCABLE CODES AND ORDINANCES FOR PERFORMANCE, WORKMANSHIP, EQUIPMENT, AND MATERIALS. ADDITIONALLY, COMPLY WITH RULES AND REGULATIONS OF PUBUC U11U11ES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. WHERE CONFUCTS BETWEEN VARIOUS CODES, ORDINANCES, RULES, AND REGULATIONS EXIST, COMPLY WITH THE MOST STRINGENT. WHEREVER REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, EXCEED THOSE OF THE ABOVE ITEMS, THE REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, SHALL GOVERN. CODE COMPUANCE, AT A MINIMUM, I5 MANDATORY. CONSTRUE NOTHING IN THESE CONSTRUCTION DOCUMENTS AS PERMITTING WORK NOT IN COMPLIANCE, AT A MINIMUM, WITH THESE CODES. BRING ALL CONFUCTS OBSERVED BETWEEN CODES, ORDINANCES, RULES, REGULATIONS AND THESE DOCUMENTS TO THE ENGINEER'S ATTENTION FOR FINAL RESOLUTION. CONTRACTOR WILL BE HELD RESPONSIBLE FOR ANY VIOLATION OF THE LAW. PROVIDE AND MAINTAIN ALL NECESSARY SIGNAL UGHTS AND GUARDS FOR THE SAFETY OF THE PUBUC. OBTAIN AND PAY FOR ALL PERMITS FOR WORK IN THIS DIVISION. 16A 1 -8 MANUFACTURERS IN OTHER ARTICLES WHERE USTS OF MANUFACTURERS ARE INTRODUCED, THE FOLLOWING REQUIREMENTS APPLY TO PRODUCT SELECTION: A. MANUFACTURERS: SUBJECT TO COMPUANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE MANUFACTURERS SPECIFIED. WHERE A UST IS PROVIDED, MANUFACTURERS ARE LISTED ALPHABETICALLY AND NOT IN ACCORDANCE WITH ANY RANKING OR PREFERENCE. 16A 1 -9 SUBMITTALS ASSEMBLE AND SUBMIT TO THE ARCHITECT, FOR ENGINEER'S REVIEW, MANUFACTURERS' PRODUCT LITERATURE FOR MATERIAL AND EQUIPMENT TO BE FURNISHED, INSTALLED, OR BOTH, UNDER THIS DIVISION, INCLUDING SHOP DRAWINGS, MANUFACTURERS' PRODUCT DATA AND PERFORMANCE SHEETS, SAMPLES, AND OTHER SUBMITTALS REQUIRED BY THIS DIVISION. PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY DIVISION 1. BEFORE SUBMITTING, VERIFY THAT ALL MATERIALS AND EQUIPMENT SUBMITTED ARE MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, AND FIT THE AVAILABLE SPACES, AND ALLOW AMPLE AND CODE— REQUIRED ROOM FOR ACCESS AND MAINTENANCE. SUBMITTALS SHALL CONTAIN THE FOLLOWING INFORMATION. SUBMITTALS NOT SO IDENTIFIED WILL BE RETURNED TO THE CONTRACTOR WITHOUT ACTION: B. C. D. THE PROJECT NAME. APPLICABLE SPECIFICATION SECTION AND PARAGRAPH. THE SUBMITTAL DATE. THE CONTRACTOR'S STAMP, WHICH SHALL CERTIFY THAT THE STAMPED DRAWINGS HAVE BEEN CHECKED BY THE CONTRACTOR, COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, AND HAVE BEEN COORDINATED WITH OTHER TRADES. TRANSMIT SUBMITTALS AS EARLY AS REQUIRED TO SUPPORT THE PROJECT SCHEDULE. ALLOW FOR TWO WEEKS ENGINEER REVIEW 11ME, PLUS MAILING TIME, PLUS A DUPUCATION OF THIS TIME FOR RESUBMITTALS, IF REQUIRED. TRANSMIT SUBMITTALS AS SOON AS POSSIBLE AFTER NOTICE TO PROCEED AND BEFORE CONSTRUCTION STARTS. THE ENGINEER'S SUBMITTAL REVIEWS WILL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR OMITTING COMPONENTS OR FITTINGS; OR COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. 16A 1 -10 ADJUSTING, AUGNING AND TESTING ADJUST, AUGN, AND TEST ALL ELECTRICAL EQUIPMENT ON THIS PROJECT PROVIDED UNDER THIS DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS FOR INSTALLATION OR WIRING UNDER THIS DIVISION, FOR PROPER OPERATION. TEST ALL SYSTEMS AND EQUIPMENT ACCORDING TO THE REQUIREMENTS IN NETA ATS (LATEST EDITION). MAINTAIN THE FOLLOWING ON THE PROJECT PREMISES AT ALL 11MES: A TRUE RMS READING VOLTMETER, A TRUE RMS READING AMMETER, AND A MEGOHMMETER INSULATION RESISTANCE TESTER. PROVIDE TEST DATE READINGS AS REQUESTED OR AS REQUIRED BY THE ENGINEER. 16A 1 -11 OPERATION AND MAINTENANCE INSTRUCTIONS SUBMIT TO THE ARCHITECT, FOR ENGINEER'S REVIEW, COPIES EACH OF OPERATIONS AND MAINTENANCE INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTALLED PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY DIVISION 1 AND INCLUDE AT A MINIMUM THE FOLLOWING INFORMATION: A. MANUFACTURERS' CATALOG AND PRODUCT DATE SHEETS B. WIRING DIAGRAMS C. MAINTENANCE INSTRUCTIONS D. OPERATING INSTRUCTIONS E. PARTS LISTS F. TEST REPORTS AS DEFINED IN NETA ATS FOR THE SYSTEMS AND EQUIPMENT PROVIDED AND INSTALLED UNDER THIS CONTRACT G. NAMES, ADDRESSES, TELEPHONE NUMBERS, AND E —MAIL ADDRESSES OF LOCAL CONTACTS FOR WARRANTY SERVICES AND SPARE PARTS SUBMIT MANUALS PRIOR TO REQUESTING THE FINAL PUNCH UST AND BEFORE ANY REQUESTS FOR SUBSTANTIAL COMPLETION. ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATIONS TO OWNER'S REPRESENTATIVE AT THE COMPLETION OF, AND BEFORE FINAL ACCEPTANCE OF, THE WORK. 16A 1 -12 SYSTEM START UP PRIOR TO STARTING UP THE ELECTRICAL SYSTEMS, CHECK ALL COMPONENTS AND DEVICES, LUBRICATE ITEMS ACCORDINGLY, AND TIGHTEN SCREWS AND BOLTS FOR CONNECTORS AND TERMINALS ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE- 11GHTENING VALUES. IF MANUFACTURE'S TORQUE VALUES ARE NOT INDICATED, USE THOSE SPECIFIED IN UL 486A. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE. CHECK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS, GROUNDING RESISTANCE, AND PROPER PHASING. BALANCE ALL SINGLE —PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE IS ACHIEVED. DO NOT TYPE UP FINAL PANELBOARD DIRECTORIES UNTIL ALL RE— BALANCING AND REDISTRIBUTION OF CIRCUITS ARE COMPLETE. REPLACE ALL BURNED —OUT LAMPS AND LAMPS USED FOR TEMPORARY CONSTRUCTION UGHTING IN PERMANENT LIGHT FIXTURES. AFTER ALL SYSTEMS HAVE BEEN INSPECTED AND ADJUSTED, CONFIRM ALL OPERATING FEATURES REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND MAKE FINAL ADJUSTMENTS AS NECESSARY. 16A 1 -13 WARRANTIES WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION, UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL CONDITIONS AND DIVISION 1. ALSO WARRANT THE FOLLOWING ADDITIONAL ITEMS: A. ALL RACEWAYS ARE FREE FROM OBSTRUCTIONS, HOLES, CRUSHING, OR BREAKS OF ANY NATURE B. ALL RACEWAY SEALS ARE EFFECTIVE C. THE ENTIRE ELECTRICAL SYSTEM IS FREE FROM ALL SHORT CIRCUITS AND UNWANTED OPEN CIRCUITS AND GROUNDS. THE ABOVE WARRANTIES SHALL INCLUDE LABOR AND MATERIAL MAKE REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE OWNER. PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM THE ENGINEER OR OWNER. AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING TERM OMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE OWNER AND STATING THE COMMENCEMENT DATE AND TERM. 16A 2 ELECTRICAL WORK 16A 2 -1 EXCAVATION AND BACKFILLING EXCAVATE ALL MATERIALS ENCOUNTERED INCLUDING ROCK REQUIRED FOR WORK UNDER THIS SECTION. BACKFILL ALL TRENCHES, COMPACTING IN 6 —INCH LAYERS. TEST UNDERGROUND SYSTEMS, CONFIRM WATERTIGHT INTEGRITY, AND OBTAIN ACCEPTANCE FROM ENGINEER AND AHJ BEFORE BACKFIWNG. REMOVE FROM PREMISES ALL EXCESS MATERIAL NOT USED IN BACKFIWNG. REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING AND OTHER FACILITIES DAMAGED. REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION. ALL BACKFIWNG AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE OWNER, CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL REQUIREMENTS OF DIVISION 2 OF THESE SPECIFICATIONS. 16A 2 -2 CLEANING IN ADDITION TO THE REQUIREMENTS OF DIVISION 1, REMOVE FROM THE PREMISES DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE ELECTRICAL WORK, AS REQUIRED, TO PREVENT ACCUMULATION. COOPERATE IN MAINTAINING REASONABLY CLEAN PREMISES AT ALL 11MES. IMMEDIATELY PRIOR TO FINAL INSPECTION, MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM THE WORK. CLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THIS DIVISION. REMOVE DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER FROM ALL SURFACES. TOUCH UP AND RESTORE ALL DAMAGED FINISHES TO THEIR ORIGINAL CONDITION. 16A 2 -3 CUTI1NG AND PATCHING FOLLOWING THE REQUIREMENTS IN DIVISION 1, CUT WALLS, FLOORS, CEILINGS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED TO PERFORM WORK UNDER THIS DIVISION. OBTAIN PERMISSION OF THE ENGINEER, OWNER, OR BOTH, BEFORE DOING ANY CUTI1NG. CUT ALL HOLES AS SMALL AS POSSIBLE. PATCH WALLS, FLOORS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED BY WORK UNDER THIS DIVISION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, INCLUDING FIRE RATINGS IF APPLICABLE. 16A 2 -4 ROUGH —IN COORDINATE WITHOUT DELAY ALL ROUGHING —IN WITH OTHER DIVISIONS. CONCEAL ALL RACEWAYS EXCEPT IN UNFINISHED AREAS ANS WHERE OTHERWISE INDICATED ON THE DRAWINGS. 16A 2 -5 RACEWAYS METAWC CONDUIT AND TUBING: A. ELECTRICAL METAWC TUBING AND FITTINGS (EMT): ANSI C80.3, UL 797 B. FLEXIBLE METAL CONDUIT (FMC): ZINC—COATED STEEL, UL 1 C. INTERMEDIATE METAL CONDUIT (IMC): HOT— DIPPED GALVANIZED RIGID STEEL CONDUIT: ANSI C80.6, UL 1242 D. LIQUIDITGHT FLEXIBLE METAL CONDUIT (LFMC): FLEXIBLE STEEL CONDUIT WITH PVC JACKET: UL 360 E. RIGID METAL CONDUIT (RMC): 1. HOT —DIP GALVANIZED RIGID STEEL CONDUIT (GRS): ANSI C80.1 UL 6 2. RIGID ALUMINUM CONDUIT (RAC): ANSI C80.5, UL 6A F. PLASTIC— COATED IMC, RMC, AND FITTINGS: NEMA RN 1, UL LISTED. G. IMC AND RMC FITTINGS: NEMA FB 1; COMPATIBLE WITH CONDUIT TYPE AND MATERIAL, UL LISTED NON — METAWC CONDUIT AND TUBING: A. ELECTRICAL NONMETAWC TUBING (ENT): NEMA TC 13, UL USTED B. UQUIDTIGHT FLEXIBLE NONMETAWC CONDUIT (LFNC): UL 1660 C. RIGID NONMETAWC CONDUIT (RNC): SCHEDULE 40 PVC: NEMA TC 2, UL 651 D. ENT AND RNC FITTINGS: NEMA TC 3, TC 6; UL 514, COMPATIBLE WITH CONDUIT /TUBING TYPE AND MATERIAL, UL LISTED 16A 2 -6 RACEWAY INSTALLATION INSTALL ALL CIRCULAR RACEWAYS CONCEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE EXCEPT WHERE OTHERWISE INDICATED. PROVIDE GRS FOR ALL CONDUITS RUN UNDERGROUND, EXPOSED TO WEATHER, OR EXPOSED TO OTHER HAZARDOUS CONDITIONS. PROVIDE GRS INSTALLED BELOW GRADE WITH A CORROSION RESISTANT BONDED— PLAS11C OR APPROVED MASTIC COATING. THIS SHALL INCLUDE THE 90— DEGREE ELBOW BELOW GRADE AND THE ENURE VERTICAL TRANSITION TO ABOVE GRADE. ALL OTHER RACEWAY MAY BE EMT WHERE APPROVED BY LOCAL CODE. USE COMPRESSION TYPE FITTINGS FOR EMT, WITH ALL FITTINGS UL LISTED FOR THE ENVIRONMENT IN WHICH THEY ARE USED. AT CONTRACTOR'S OPTION, PVC CONDUIT MAY BE USED UNDERGROUND WHERE PERMIIIEU BY LOCAL CODE AND WHERE NOT SPECIFICALLY RESTRICTED BY THESE DOCUMENTS. USE FMC FOR FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER, AND TO ANY DEVICE THAT WOULD OTHERWISE TRANSMIT MOTION, VIBRATION, OR NOISE. WHERE EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, USE LFMC. PROVIDE ALL FMC AND LFMC WITH AN INSULATED GROUND WIRE USE ONLY METAL RACEWAYS FOR ALL POWER WIRING FROM THE OUTPUT OF VARIABLE FREQUENCY DRIVES TO THEIR RESPECTIVE MOTORS. INSTALL RACEWAYS PARALLEL TO BUILDING LINES. INSTALL RACEWAYS TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. INSTALL RACEWAY TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, REINFORCING STEEL, AND OTHER IMMOVABLE OBSTACLES. INSTALL RACEWAYS SET IN FORMS FOR CONCRETE STRUCTURE IN SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ENGINEER, INSTALL NO RACEWAY IN A SLAB —ON— GRADE. LOCATE RACEWAY BELOW GRANULAR FILL BELOW SLABS —ON —GRADE INSTALL RACEWAYS CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 90— DEGREE BENDS BETWEEN CONNECTIONS. USE MANUFACTURED ELBOWS FOR ALL 45— AND 90— DEGREE BENDS, UNLESS APPROVED BY THE ENGINEER IN ADVANCE. MAKE OTHER BENDS SMOOTH AND EVEN AND WITHOUT FLATTENING RACEWAY OR FLAKING GALVANIZING OR ENAMEL RADII OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE CORRESPONDING TRADE ELBOW. USE LONG RADIUS ELBOWS WHERE NECESSARY, INDICATED, OR BOTH. SECURELY FASTEN RACEWAYS IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. ATTACH RACEWAY SUPPORTS TO THE BUILDING STRUCTURE. HANG SINGLE RACEWAYS FOR FEEDERS WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. CLAMP GROUPS OF HORIZONTAL FEEDER RACEWAYS TO STEEL CHANNELS THAT ARE SUSPENDED FROM INSERTS SPACED NOT OVER 10 Fkkl APART IN CONSTRUCTION ABOVE. SECURELY CLAMP VERTICAL FEEDER RACEWAYS TO STRUCTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. INSTALL CABLE CLAMPS FOR SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. ADD RACEWAY SUPPORTS WITHIN 12 INCHES OF ALL BENDS, ON BOTH SIDES OF THE BENDS. DO NOT SUPPORT RACEWAYS FROM SUSPENDED CEILING COMPONENTS. REAM RACEWAY ENDS, THOROUGHLY CLEAN RACEWAYS BEFORE INSTALLATION, AND KEEP CLEAN AFTER INSTALLATION. PLUG OR COVER OPENINGS AND BOXES AS REQUIRED TO KEEP RACEWAYS CLEAN DURING CONSTRUCTION AND FISH ALL RACEWAYS CLEAR OF OBSTRUCTIONS BEFORE PUWNG CONDUCTORS WIRES. PROVIDE RACEWAYS OF AMPLE SIZE FOR PUWNG OF WIRE AND NOT SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 34 —INCH IN SIZE, UNLESS INDICATED OTHERWISE ON DRAWINGS. PROTECT ALL RACEWAY INSTALLATIONS AGAINST DAMAGE DURING CONSTRUCTION. REPAIR ALL RACEWAYS DAMAGED OR MOVED OUT OF LINE AFTER ROUGHING —IN TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. AUGN AND INSTALL TRUE AND PLUMB ALL RACEWAY TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION BOXES. INSTALL APPROVED EXPANSION /DEFLECTION FITTINGS WHERE RACEWAYS PASS THROUGH OR ACROSS EXPANSION JOINTS. INSTALL A PULL WIRE IN EACH EMPTY RACEWAY THAT I5 LEFT FOR INSTALLATION OF CONDUCTORS OR CABLES UNDER OTHER DIVISIONS OR CONTRACTS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC UNE WITH NOT LESS THAN 200 —LB TENSILE STRENGTH. LEAVE AT LEAST 12 INCHES OF SLACK AT EACH END OF PULL WIRE. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER THAT WILL ENSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY. INSTALL CONDUIT — SEALING FITTINGS IN ALL RACEWAYS PASSING FROM NON— HEATED TO HEATED SPACES. 16A 2 -7 BUSHINGS AND LOCKNUTS RIGIDLY CLAMP CONDUITS ENTERING SHEET METAL BOXES TO THE BOX WITH A BUSHING AND LOCKNUT ON THE INSIDE AND A LOCKNUT ON THE OUTSIDE. CONDUIT SHALL ENTER THE BOX SQUARELY. PROVIDE BUSHINGS AND LOCKNUTS MADE OF GALVANIZED MALLEABLE IRON WITH SHARP, CLEAN —CUT THREADS. WHERE EMT ENTERS A BOX, PROVIDE APPROVED EMT COMPRESSION CONNECTORS. USE INSULATED AND /OR GROUNDING BUSHINGS WHEREVER CONNECTION IS SUBJECT TO VIBRATION OR MOISTURE, WHEN REQUIRED BY NFPA 70, OR BOTH. 16A 2 -8 SUPPORT SYSTEMS STEEL SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH MFMA -3, FACTORY — FABRICATED COMPONENTS FOR FIELD ASSEMBLY; 12— GAUGE, 1 -5/8 —INCH BY 1 -5/8 —INCH; COPPER B —LINE, ERICO INTERNATIONAL CORPORATION, POWER— STRUT, THOMAS & BETTS CORPORATION, UNISTRUT. FINISHES: METAWC COATINGS: HOT —DIP GALVANIZED AFTER FABRICATION AND APPLIED ACCORDING TO MFMA -3 NONMETAWC COATINGS: MANUFACTURER'S STANDARD PVC, POLYURETHANE, OR POLYESTER COATING APPLIED ACCORDING TO MFMA -3. PAINTED COATINGS: MANUFACTURER'S STANDARD PAINTED COATING APPUED ACCORDING TO MFMA -3. STAINLESS STEEL: TYPE 304, PER ASTM A240. ALUMINUM (EXTRUDED): TYPE 6063 —T6, PER ASTM B221 FIELD FABRICATION: WHERE FIELD CUTTING OF STANDARD LENGTHS OF CHANNEL ARE REQUIRED, MAKE CUTS STRAIGHT AND PERPENDICULAR TO MANUFACTURED SURFACES. FOR FIELD —CUT OR DAMAGED SURFACES OF COATED CHANNELS, DRESS CUT ENDS, DAMAGED SURFACES, OR BOTH, WITH AN ABRASIVE MATERIAL (E.G., FILE, GRINDING STONE, OR SIMILAR) AND CLEANSER TO REMOVE OILS, RUST, SHARP EDGES AND SHARDS. FOR CHANNEL WITH A FACTORY — APPLIED COATING, RE —FINISH CUT EDGES WITH A COATING COMPATIBLE WITH THE FACTORY FINISH AND AS RECOMMENDED BY THE MANUFACTURER (E.G., MANUFACTURER'S TOUCH —UP PAINT OR ZINC —RICH COLD— GALVANIZING COMPOUND, AS APPLICABLE). 16A 2 -9 CONDUCTORS PROVIDE COPPER CONDUCTORS, WITH UL LABEL, AND 600V INSULATION. SERVICE LATERAL CONDUCTORS: TYPE THWN OR XHHW WITH STRANDED CONDUCTORS. All FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 8 AWG AND LARGER: STRANDED, TYPE THWN OR XHHW INSULATION. ALL CONDUCTORS, NO. 10 AWG AND SMALLER, USED FOR POWER AND LIGHTING CIRCUITS: SOLID COPPER, TYPE THWN (WET OR DAMP LOCATIONS, OR IN CONDUIT BELOW GRADE OR SLAB), TYPE THHN (DRY LOCATIONS ONLY AND ABOVE GRADE) INSULATION, OR DUAL —RATED TYPE THHN/THWN. ALL BRANCH CIRCUIT WIRING: NOT SMALLER THAN NO. 12 AWG. IF NO CONDUCTOR SIZE IS INDICATED ON THE DRAWINGS FOR A BRANCH CIRCUIT, PROVIDE NO. 12 AWG CONDUCTORS AND A 20A CIRCUIT BREAKER. CONDUCTORS FIELD — INSTALLED WITHIN FLUORESCENT LIGHT FIXTURE CHANNELS: TYPE THHN. CONTROL WIRING: STRANDED COPPER CONDUCTORS, 600V INSULATION, OF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO ACCOMPLISH SPECIFIED FUNCTION. MINIMUM SIZE: NO. 18 AWG, UNLESS OTHERWISE NOTED. 16A 2 -10 WIRING INSTALLATION EXCEPT WHERE SPECIFIED OR INDICATED, FOR LOW — VOLTAGE WIRING, INSTALL ALL WIRING IN APPROVED RACEWAY AND ENCLOSURES. SUPPORT ALL CONDUCTORS AND CABLES IN VERTICAL INSTALLATIONS, AS REQUIRED BY NFPA 70, BY INSTAWNG CABLE SUPPORTS OR PLUG —TYPE CONDUIT RISER SUPPORTS, OR WIRE —MESH SAFETY GRIPS. INSTALL ALL CONDUCTORS AND CABLE IN RACEWAYS CONTINUOUS WITHOUT TAPS OR SPLICES. SPUCE OR TAP ONLY IN APPROVED BOXES AND ENCLOSURES WITH APPROVED SOLDERLESS CONNECTORS, OR CRIMP CONNECTORS AND TERMINAL BLOCKS FOR CONTROL WIRING, AND KEEP TO THE MINIMUM REQUIRED. INSULATE ALL SPLICES, TAPS, AND JOINTS AS REQUIRED BY CODES. ALL MATERIALS USED TO TERMINATE, SPLICE, OR TAP CONDUCTORS: DESIGNED FOR, PROPERLY SIZED FOR, AND UL LISTED FOR THE SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S RECOMMENDED TOOLS. WHERE WIRING I5 INDICATED AS INSTALLED, BUT THE CONNECTION IS INDICATED "FUTURE" OR "BY OTHER DIVISION, TRADES, OR CONTRACTS", LEAVE A MINIMUM 3 —FOOT "PIGTAIL" AT THE BOX, TAPE NE ENDS OF THE CONDUCTORS, AND COVER THE BOX. THE NUMBER OF CONDUCTORS IN A SPECIFIC RACEWAY "HOME RUN" IS INDICATED WITH CROSS LINES (TICK MARKS) ON EACH "CIRCUIT RUN" ON THE DRAWINGS. IN GENERAL THE DIRECTION OF BRANCH CIRCUIT "HOME RUN" ROUTING I5 INDICATED ON THE DRAWINGS COMPLETE WITH CIRCUIT NUMBERS AND PANELBOARD DESIGNATION. CONTINUE ALL SUCH "HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS THOUGH "CIRCUIT RUNS" WHERE INDICATED IN THEIR ENTIRETY. WHEN MULTIPLE HOME RUNS ARE COMBINED INTO A SINGLE RACEWAY SUCH THAT THE NUMBER OF CONDUCTORS EXCEEDS FOUR (CONDUCTOR COUNT IS MADE UP OF ANY COMBINATION OF PHASE AND NEUTRAL CONDUCTORS), THE FOLLOWING RESTRICTIONS APPLY, WHICH ARE IN ADDITION TO THOSE IN NFPA 70: NORMAL OR NONESSENTIAL CIRCUITS MAXIMUM OF 16 CONDUCTORS IN A SINGLE RACEWAY. FOR UP TO EIGHT CONDUCTORS IN A RACEWAY, MINIMUM RACEWAY SIZE: 3/4 —INCH. FOR GREATER THAN EIGHT CONDUCTORS, MINIMUM RACEWAY SIZE: 1 —INCH. DO NOT INSTALL ANY OTHER TYPE OF CIRCUIT IN THIS RACEWAY. THE MINIMUM WIRE SIZE FOR ALL CONDUCTORS IN THIS RACEWAY: N0.10 AWG. ONLY 15A AND 20A BRANCH CIRCUIT HOMERUNS MAY BE COMBINED INTO ONE RACEWAY. GFCI CIRCUITS DO NOT USE MULTI — CONDUCTOR CIRCUITS, WITH A SHARED NEUTRAL, FOR ANY GFCI CIRCUIT BREAKER OR RECEPTACLE CIRCUIT. FOR BRANCH CIRCUITS FED FROM GFCI CIRCUIT BREAKERS, LIMIT THE ONE —WAY CONDUCTOR LENGTH TO 100 FEEI BETWEEN THE PANELBOARD AND THE MOST REMOTE RECEPTACLE OR LOAD ON THE GFCI CIRCUIT. WIRING SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH COLOR CODE SYSTEM IN THE TABLE BELOW. IN LARGER SIZES, WHERE PROPERLY COLORED INSULATION IS NOT AVAILABLE, USE VINYL PLASTIC ELECTRICAL TAPE OF THE APPROPRIATE COLOR AROUND EACH CONDUCTOR AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES. System Voltage 208Y/120 480Y/277 Conductor Type Phase A Phase B Phase C Neutral Equipment Ground Isolated Ground Phase A Phase B Phase C Neutral Equipment Ground Isolated Ground Color Black Red Blue White Green Green w /yellow stripe Brown Orange Yellow Grey Green Green w /yellow stripe PROPERLY NUMBER ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING FOR IDENTIFICATION WITH VINYL STICK —ON MARKERS OR EQUIVALENT. PROVIDE AN EQUIPMENT—GROUNDING CONDUCTOR, OR BONDING JUMPER, AS APPLICABLE, IN ALL BRANCH CIRCUITS AND FEEDERS, SIZED IN ACCORDANCE WITH NFPA 70 TABLES 250.66 OR 250.12.2, AS APPLICABLE, UNLESS INDICATED AS LARGER ON THE DRAWINGS. VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 2 PERCENT. 16A 2 -11 JUNCTION BOXES. PULL BOXES, CABINETS AND WIREWAYS PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER NECESSARY FOR PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS ACCORDING TO NFPA 70 AND WHERE INDICATED ON THE DRAWINGS. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER IS LARGER. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED. JUNCTION BOXES INSTALLED BEHIND WALL CASES, AND IN OR ON OTHER STORE FIXTURES, EXCEPT WHERE OTHERWISE SPECIFIED, SHALL BE 4 —INCH SQUARE OR LARGER, WITH GALVANIZED COVERS. 16A 2 -12 OUTLET BOXES ALL OUTLETS INCLUDING LIGHT FIXTURE, SWITCH, RECEPTACLE, AND SIMILAR OUTLETS: NATIONAL ELECTRICAL APPLETON, STEEL CITY, RACO, OR APPROVED EQUAL GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY NFPA 70, WHICHEVER I5 LARGER. SET ALL OUTLET BOXES IN WALLS, COLUMNS, FLOORS, OR CEUNGS SO THEY ARE FLUSH WITH THE FINISHED SURFACE, ACCURATELY SET, AND RIGIDLY SECURED IN POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND /OR MASONRY RINGS AS REQUIRED FOR FLUSH MOUNTING. PROVIDE APPROVED CAST OUTLET BOXES, WITH HUBS AND WEATHERPROOF COVERS, IN ALL AREAS SUBJECT TO DAMP, WET, OR HARSH CONDITIONS. 16A 2 -13 OUTLET LOCATIONS COORDINATE LOCATIONS OF OUTLET BOXES, OUTLETS ARE ONLY APPROXIMATELY LOCATED ON THE SMALL SCALE DRAWINGS. USE GREAT CARE IN THE ACTUAL LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED DRAWINGS USED BY OTHER DIVISION TRADES, AND BY SECURING DEFINITE LOCATIONS FROM THE ARCHITECT. 16A 2 -14 MOUNTING HEIGHTS UNLESS NOTED OTHERWISE, INSTALL WIRING DEVICES AS INDICATED BELOW (NOTE: ALL DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET BOX UNLESS NOTED OTHERWISE): A. RECEPTACLES: 1. GENERAL A. VERTICALLY WITH THE GROUND SLOT MOUNTED AT THE TOP: 16 INCHES ABOVE FINISHED FLOOR B. HORIZONTALLY, WITH NEUTRAL SLOT MOUNTED AT THE BOTTOM: 16 INCHES ABOVE FINISHED FLOOR. 2. ABOVE COUNTERS: A. FOR 36 —INCH HIGH COUNTER TOPS: 44 INCHES ABOVE FINISHED FLOOR, VERTICALLY. B. FOR 34 —INCH HIGH COUNTER TOPS: 40 INCHES ABOVE FINISHED FLOOR, VERTICALLY B. C. 3. MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS AND JANITORS CLOSETS: 44 INCHES ABOVE FINISHED FLOOR, VERTICALLY. 4. WEATHERPROOF EXTERIOR RECEPTACLES: 24 INCHES ABOVE FINISHED GRADE OR AS INDICATED ON DRAWINGS, VERTICALLY. 5. GFCI RECEPTACLES: SAME AS GENERAL RECEPTACLES. 6. ISOLATED GROUND RECEPTACLES: SAME AS GENERAL RECEPTACLES. 7. TVSS RECEPTACLES: SAME AS GENERAL RECEPTACLES. 8. CONCRETE BLOCK WALLS: DIMENSIONS ABOVE MAY BE ADJUSTED SLIGHTLY, AS REQUIRED TO COMPENSATE FOR VAIABLE JOINT DIMENSIONS, SUCH THAT BOTTOM OR TOP OF BOXES, AS APPLICABLE, ARE AT BLOCK JOINTS. SWITCHES: 1. GENERAL: 44 INCHES ABOVE FINISHED FLOOR. 2. ABOVE COUNTERS: SAME AS FOR RECEPTACLES. 3. CONCRETE BLOCK WALLS: 40 INCHES ABOVE FINISHED FLOOR (DIMENSIONS MAY BE ADJUSTED SLIGHTLY, AS REQUIRED TO COMPENSATE FOR VARIABLE JOINT DIMENSIONS, SUCH THAT BOTTOM OF BOXES ARE AT BLOCK JOINTS). TELEPHONE /DATA OUTLET BOXES: 1. GENERAL MATCH MOUNTING HEIGHT OF ADJACENT WIRING DEVICE LISTED ABOVE. 2. WALL— MOUNTED TELEPHONE: 40 INCHES ABOVE FINISHED FLOOR. 16A 2 -15 WIRING DEVICES PROVIDE THE FOLLOWING WIRING DEVICES WHERE SHOWN ON DRAWINGS OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL EQUIPMENT MAY BE MADE TO COMPLY WITH STRUCTURAL AND BUILDING REQUIREMENTS AS DETERMINED IN THE COURSE OF CONSTRUCTION. PROVIDE ALL WIRING DEVICES OF THE SAME MANUFACTURER AND NOT MIXED ON THE PROJECT, TO THE MAXIMUM EXTENT POSSIBLE. PROVIDE THE COLOR OF TOGGLES AND RECEPTACLES AS REQUESTED BY THE ENGINEER. Pass & WFing Type of Device Hubbell Seymour Leviton Devices Simplex Receptacle FEEL 5361 5361 5361 5361 Duplex Receptacle HBL 5362 5362 5362 5362 Single Pale Switch HBL1221 PS 20 AC1 1221 -2 2221 Three —way Switch HBL1223 PS 20 AC3 1223 -2 2223 16A 2 -16 SWITCH AND OUTLET COVER PLATES SWITCH AND OUTLET PLATES: COLORED, SMOOTH NYLON; BY THE SAME MANUFACTURER AS THE WIRING DEVICES, WHEREVER POSSIBLE. VERIFY DESIRED MATERIALS AND COLORS WITH ENGINEER BEFORE INSTALLATION. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES: STAMPED STEEL, CADMIUM PLATED. INSTALL GROUPS OF SWITCHES UNDER ONE GANGED — PLATE, USUALLY HORIZONTALLY; OR, WHERE REQUIRED BY DETAILS, VERTICALLY. SET ALL COVER PLATES PLUMB, PARALI Fl , AND FINISHED FLUSH WITH THE WALL 16A 2 -17 WEATHERPROOF COVER PLATES PROVIDE GFCI RECEPTACLES FOR DESIGNATED WEATHERPROOF RECEPTACLES, UNLESS INDICATED OTHERWISE ON THE DRAWINGS. FOR UNATTENDED, WET LOCATIONS: IN —USE NEMA 3R, UL— LABELED PLATES MOLDED FROM A CLEAR HIGH IMPACT ULTRAVIOLET STABILIZED POLYCARBONATE MATERIAL FOR EASY VERIFICATION THAT CORDS ARE PLUGGED IN AND THAT THE GFCI IS FUNCTIONING. FOR ATTENDED WET OR DAMP LOCATIONS: WEATHERPROOF COVER PLATES, UL—USTED FOR WET LOCATIONS WITH COVER(S) CLOSED; DIE —CAST ALUMINUM OR TYPE 302 STAINLESS STEEL; SINGLE —COVER FOR SWITCHES AND VERTICALLY MOUNTED RECEPTACLES; DOUBLE —COVER FOR HORIZONTALLY MOUNTED RECEPTACLES; SELF—CLOSING COVERS zumez SOUTHW TER MALL SPAGE # 2115 633 SourscansTER SKiniz, WA 98188 MURPHY V REYps DAVID I. MURPHY, AIA moot Huse Ames Otass ii B..ss, Maim= g8eu T: so6.34c.9875 r: sob grn S: .w.. MuvnYYm ooi Harrison French and Associates 809 S.W. "A" Street Bentonville, AR 72712 (479) 273 -7780 fax (479) 273 -9436 EXPIRES: 07/22/08 IiEWE® FUI COVER PLATES: BY THE SAME MANUFACTURER AS THE WIRING D VI COMPLIANCE E C _ COMPLYING WITH NFPA 70 406.8 (A) OR (B) REQUIREMENTS FOR NEC ATTENDED OR UNATTENDED USE AS APPLICABLE. NFPA 70 16A 2 -18 FIRESTOPPING FLOOR AND WALL PENETRATIONS FIRE — RESISTANT PENETRATION SEALANTS: TWO —PART, FOAMED —IN— PLACE, SILICONE SEALANT FORMULATED FOR USE IN THROUGH — PENETRATION FIRE — STOPPING AROUND CABLES, RACEWAYS, AND CABLE TRAY PENETRATIONS THROUGH FIRE —RATED WALLS AND FLOORS. SEALANTS AND ACCESSORIES SHALL HAVE FIRE — RESISTANCE RATINGS INDICATED, AS ESTABLISHED BY TESTING IDENTICAL ASSEMBLIES IN ACCORDANCE WITH ASTM E 814, BY UNDERWRITERS' LABORATORIES, INC., OR OTHER NRTL ACCEPTABLE TO AHJ. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING: 1. "3M FIRE STOP FOAM #2001, " 3M CORP. 2. "METACAULK 835 +, " RECTORSEAL 3. "SPECSEAL PENSIL 200 SIUCONE FOAM," SPECIFY TECHNOLOGY INC. 4. "FIRE STOP SYSTEM," UNITED STATES GYPSUM COMPANY. 16A 2 -19 EQUIPMENT IDENTIFICATION PROVIDE EQUIPMENT IDENTIFICATION NAMEPLATES ON ALL PANELBOARDS, SWITCHES, AND WHERE INDICATED ON THE DRAWINGS. NAMEPLATES: A. ENGRAVED, CONTRASTING COLOR, THREE — LAYER, LAMINATED PLASTIC INDICATING THE NAME OF THE EQUIPMENT, LOAD, OR CIRCUIT AS DESIGNATED ON THE DRAWINGS AND IN THE SPECIFICATIONS. B. FIELD—APPUED PERMANENT EPDXY ADHESIVE, COMPATIBLE WITH THE EQUIPMENT FINISH, ATTACHMENT METHOD SHALL BE ACCEPTABLE TO THE MANUFACTURERS OF THE EQUIPMENT TO WHICH THE NAMEPLATES ARE BEING APPLIED. C. COLOR: BLACK BACKGROUND WITH WHITE LETTERS FOR NORMAL POWER; LEIIER HEIGHT: 1/2 —INCH MINIMUM APR - 3 -MB city Tikvuila B IL N NISI RECEIVED CITY OF TUKWIIA MAR 2 8 ZOU8 PERMIT CENTER PROJECT NUMBER: 05-08 -02008 ZUMIEZ STORE NUMBER: 19 ISSUED FoR: PRELIMINARY MALL REVIEW DATE: 02-08-08 PRELIMINARY MALL REVIEW SHEET TITLE: ELECTRI CAL SPECS SHEET NUMBER: E4