ELECTRICAL PERMIT
Parcel No.: 6364200010
Address: 2646 SOUTHCENTER MALL TUKW
Suite No:
Permit Number: EL08 -328
Issue Date: 04/18/2008
Permit Expires On: 10/15/2008
Tenant:
Name: ZUMIEZ
Address: 2646 SOUTHCENTER MALL , TUKWILA WA
Owner:
Name: WESTFIELD PROPERTY TAX DEPT Phone:
Address: PO BOX 130940 , CARLSBAD CA
Contact Person:
Name: DAVID MURPHY Phone: 206 341 -9875
Address: 2101 9 AV #211 , SEATTLE WA
Contractor:
Name: J C ELECTRIC INC
Address: 118 NW 184 ST , RIDGEFIELD WA
Contractor License No: JCELEI *043N7
Phone: 360 - 887 -7889
Expiration Date: 08/27/2008
DESCRIPTION OF WORK:
ELECTRICAL FOR NEW TENANT IMPROVEMENT TO INCLUDE CASEWORK, LIGHTING, AND STORE
FRONT.
Value of Electrical: $30,000.00
Type of Fire Protection:
Electrical Service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
Fees Collected:
National Electrical Code Edition:
$717.50
2005
Date: Li— g` Q 8
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether ecified herein or not.
The granting of this permit d• _ • •t presume • »' a authority to violate or cancel the provisions of any other state or local laws regulating
construction or the perf • of work. thorized to sign and obtain this electrical permit.
Signature:
Print Name:
J CaA \v\A.tyrt
Date: `t 1(6(0.Y)
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/07
EL08 -328 Printed: 04 -18 -2008
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.ci.tukwila.wa.us
PERMIT CONDITIONS
Parcel No.: 6364200010
Address: 2646 SOUTHCENTER MALL TUKW
Suite No:
Tenant: ZUMIEZ
Permit Number: EL08 -328
Status: ISSUED
Applied Date: 03/28/2008
Issue Date: 04/18/2008
1: ** *ELECTRICAL * **
2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and
ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to • ' e authority to violate or cancel the provision of any other work or local
laws regulating construction or the performan ,ork.
Signature:
Print Name:
Jon Csx.A
Date:
doc: Cond -Elec
EL08 -328 Printed: 04 -18 -2008
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
htto: //www. ci. tkwila. wa. us
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
Site Address: z ,c0011-1 LEiJTI M/ L
Tenant Name: 7■_)M
King Co Assessor's Tax No.: h _ (4Z 0 - 00 I
Suite Number: Ve410 Floor: 7
New Tenant: ,Ej Yes ❑ ..No
Property Owners Name: V\i r;TT i I LA C OR ror ATI c
Mailing Address: I I , 0 1 1N11_ -1-1- LT- g 912rir Clam t L.-PS 1 (A 170 2 5
City State Zip
Name: DAJ iD AAQiz,P}- -'
Day Telephone: (2ote- .) S.1\ —o'ie s-
Mailing Address: Z C 1 ci . Avg l I $I P-ti_l WA 1$ Ia.)
City State Zip
E -Mail Address: jMJf 1419 o ,norpl- ) J re , ( ors Fax Number: (-2C.6' fit- -II - `.1 I q-q
ELECTRI+
Company Name: 4:1)
Mailing Address:
city
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
State
Zip
Valuation of Project (contractor's bid price): $ ;0 1 000
Scope of Work (please provide detailed information): 14-E,u,' 101 Slc Talk-MT lA.tpgcN5- i'A E KI T I1/44
40 vth r e NTF - ( l z t / . iy S P A t e ' — vv CA4Fta r-et4 < L 16-H't1 IdG
51-C1 cN1" µpc44Mf t CAL AINto Et Ee'TQaL-
Will service be altered? ❑ Yes (j No Adding more than 50 amps? ❑ Yes
Type of Use: Fe -mil-
Type of work:
❑ New ❑ Addition ❑ Service Change ❑ Remodel Dit Tenant Improvement
❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service
Property Served by:
tg Puget Sound Energy
❑ Seattle City Light
H3ApplicationsTorms- Applications On Lineal -2007 - Electrical Permit AppIication.doc
bh
Page 1 of 2
•
•
•
RESIDENTIAL
NEW RESIDENTIAL SERVICE
❑ New single family dwellings $140.00
(including an attached garage)
❑ Garages, pools, spas and outbuildings $75.00 ea
❑ Low voltage systems
(alarm, furnace thermostat) $55.00 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $75.00
(no added/altered circuits)
❑ Service change with added/altered circuits $75.00
number of added circuits $ I0.00 ea
❑ Circuits added/altered without service change $50.00
(up to 5 circuits)
❑ Circuits added/altered without service change $50.00
(6 or more circuits) $7.00 ea
❑ Meter /mast repair $65.00
❑ Low voltage systems $55.00
(alarm, furnace thermostat)
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ 'Temporary service (residential) $58.00
❑ Temporary service (generator) $75.00
❑ Manufactured/mobile home service $80.00
(excluding garage or outbuilding)
❑ Carnivals $75.00
Number of concessions $10.00 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing
and justifiable causc demonstrated.
1 1IEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED 'I'HIS APPLICATION AND KNOW II IE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY TIIE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER O. ELECTRICAL CONT t CTOR: E. FIT
Signature: , `
Print Name: (P 2 / IJ(PTSV1yto-Ca Day Telephone: AV 34 1 - l el G
Mailing Address:
Date: 1 "2e'- v'17
,2-(c. I H ► Weird t•& e:01 rg 2r ► rn.E , w P i 2
City Slate Zip
IDate Application Accepted:
VI_ ��1ry+licniinnr4nmx- Applicalinnk nn Lux .1-21)10 - Circuital I'ennn Appllcafnn.J,M
hh
Date Application Expires:
01. l 0 t GI) Staff Initials:
Page 2or2
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http: / /www.ci.tukwila.wa.us
RECEIPT
Parcel No.: 6364200010 Permit Number: EL08 -328
Address: 2646 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 03/28/2008
Applicant: ZUMIEZ Issue Date:
Receipt No.: R08 -01233
Initials: WER
User ID: 1655
Payment Amount: $574.00
Payment Date: 04/18/2008 01:32 PM
Balance: $0.00
Payee: j C ELECTRIC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 1647 574.00
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.0 574.00
Total: $574.00
1319 04/18 9711 TOTAL 574.00
rtor: Rar.eint -(1R Printatt• 04- 1R -7(N)R
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 -431 -3665
Web site: http:/lwww.ci.tukwila.wa.us
SET RECEIPT
RECEIPT NO: R08 -00957
Initials: JEM Payment Date: 03/28/2008
User ID: 1165
Payee: MURPHY VAREY, P.S.
Total Payment: 312.03
SET ID: S000000989 SET NAME: Tmp set/Initialized Activities
SET TRANSACTIONS:
Set Member Amount
D08- 157 57.53
;. , EL08:;d3218
143.50
M08 -094 79.00
PG08 -097 32.00
TOTAL: 312.03
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 12013 312.03
TOTAL: 312.03
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
PLAN CHECK - NONRES
000.345.832.00.0 143.50
000/345.830 168.53
TOTAL: 312.03
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION 1'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 6 0
6A-3a
Project: /
ZJ�1LZ.•
Type of Inspection:
. /co
N.1
Address: l 4 (9 _ d , ,i , '
�'�V
Date Called:
Special Instructions:
Date Wanted:
7 z
a.m.
P.m
Requester:
Phone No:
ElApproved per applicable codes. ❑ Corrections required prior to approval.
COMMENTS:
6,),A
Inspector:
j;1 6644K
Date: cri fr 3 b'
El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION RECORD ,� fig.
Retain a copy with permit O
INSPE ION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION /2'
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3f 7
ZProject: 1 t e i—
Type of Inspection: / oO
5Td Sic
Address: y G Lt G ' �vv
Date Called:
FJ*t.. KWPfisir, rice 1 Pc r> it
,..
Special Instructions:
Date Wanted:
2 3
7/e
a.m
Requester:
Phone No:
I-
DApproved per applicable codes.
ElCorrections required prior to approval.
COMMENTS:
Yti-
5Td Sic
FJ*t.. KWPfisir, rice 1 Pc r> it
, f P2imd a ( (A 1 t.F'ri mi
- SJRv• si for Rckdia togov6 Lo V
p
Inspector:
..Sti6ovi)6is
'Date: 07/73/A,
ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION RECORD
Retain a copy with permit 16 I•1
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION M"
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 7
INSPECTION NO.
Project: Zdfl 1ei_
Type of Inspection:_ 700
Address: Z4) 4 GI
� j _ - _
�"^{�
Date Called:
Special Instructions:
Date Wanted:
1(24 . .
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Ctflusv'�
Ko y q N 14
Inspector:
-del 17Jt/tl\ (Date: 01 /i
El$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
'Date:
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION II-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: ZV- A 'CZ'
P'�
Type of Inspection:
700 3
Address:
��,/�
Date Called:
Special Instructions:
Date Wanted:
71 (1 ]„
AY
Requester:
Phone No:
0 Approved per applicable codes. LJ Corrections required prior to approval.
COMMENTS:
Inspector:
•i-Pi &Welk
El $60.00 REINSPECTION FEE RE UIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date: 07/A74
l
Receipt No.:
IDate:
- _. _ - -- - - -
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION P-
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: Zdki 16Z-
Type of Inspection:
lfoi-
Address: 2( 94 ! miitti.
Date Called:
Special Instructions:
Date Wanted: Ik' p.m
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
D
.14 , v 5tedicA6
•
Inspector:
Jr &dal
Date: 17� fp o
❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Receipt No.:
!Date:
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #1.00, Tukwila, WA 98188 (206)431 -3670
61,0Y-3A
Project: z ti ti I Ez
Type of Inspection:
7A�3
W
Address:
2 (0 WO el m.
Date Called:
Special Instructions:
Date Wanted:
5,7z...0
p.m.
Requester:
Phone No:
0 Approved per applicable codes. Ei Corrections required prior to approval. gm
COMMENTS:
u wm,t/ ciAck
Inspector:
aTi 664A/cc
Date: 05/244
Ej $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Receipt No.:
Date:
PERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL08 -328
PROJECT NAME: ZUMIEZ
DATE: 03 -28 -08
SITE ADDRESS: 2646 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS: �jEN 4,11-06
Buirding Division Lk
Public Works
Fire Prevention
Structural
n
Planning Division
nPermit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete
DUE DATE: 04-01-08
Not Applicable
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required
No further Review Required
DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS:
DUE DATE: 04-29-08
Not Approved (attach comments)
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Look Up a Contractor, Electric or Plumber License Detail
Washington State Department of Labor and Industries
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of
its specialty. Electrical Contractors must maintain a surety bond or
assignment of savings account. They also must have a designated
Electrical Administrator or Master Electrician who is a member of the
firm or a full -time supervisory employee.
License Information
License
JCELEI *043N7
Licensee Name
J C ELECTRIC INC
Licensee Type
ELECTRICAL CONTRACTOR
UBI
601731772
Ind. Ins. Account Id
AGENT
Business Type
CORPORATION
Address 1
118 NW 184TH ST
Address 2
City
RIDGEFIELD
County
CLARK
State
WA
Zip
98642
Phone
3608877889
Status
ACTIVE
Specialty 1
GENERAL
Specialty 2
UNUSED
Effective Date
8/27/1996
Expiration Date
8/27/2008
Suspend Date
Separation Date
Parent Company
Previous License
JCELE * *055JD
Next License
Associated License
COULIJN976NK
Master Electrician Information
License
COULIJN976NK
Name
COULIMORE, JON N
Status
ACTIVE
Business Owner Information
Name
Role
Effective Date
Expiration Date
COULIMORE, JON
01/01/1980
COULIMORE, JON
AGENT
01/01/1980
Bond Information
1
Page 1 of 2
https: // fortress .wa.gov /lni/bbip /printer.aspx ?License = JCELEI *043N7 04/18/2008
TO CIRCUIT BREAKER 13-19
TO CIRCUIT BREAKER 13-21
TO CIRCUIT BREAKER B -23
TO CIRCUIT BREAKER B -25
(16.100)SWITCH
BANK
SEPARATE PERMIT
REQUIRED FOR:
eiMethanical
Plumbing
liGas Piping
City of Tukwila
BUILDING DIVISION
TO SWITCH Se
TO SWITCH Sf
TO SWITCH Sg
TO SWITCH Sh
CONTRACTOR TO PROVIDE "BULLET SERIES"
CURRENT UMIIING PANEL BY LIGHTING CONTROL
AND DESIGN, INC. (323) 226 -0000
www.lightingcontrols.com. MODEL #T24 -6 —SM.
CURRENT LIMITING PANEL
N.T.S.
LIGHTING FIXTURE SCHEDULE
TYPE
MANUFACTURER
CATALOG NUMBER
VOLTS
WATTS
LAMP
ORDER NUMBER
QTY
DESCRIPTION
NOTES
A
B
HUBBELL
JUNO
SWD- 175— El —AP —WH
120
218
175W MN
1
PENDANT
4,5
#R731 BL, 20, #R23,
11.
34, BLACK
120
50
50W MR16 /NSP
1
TRACK LIGHTING
4,5
C
RESOLUTE
#3619 —TOR
120
40
40W —A19 —CLEAR
1
PENDANT
1,4
D
JUNO
#133BL /T30713L
120
50
50W PAR30 NSP
1
TRACK LIGHTING
4,5
01
JUNO
#133BL/T307BL
120
50
50W PAR30 NFL
1
TRACK LIGHTING
4,5
H
RESOLUTE
#3629 —TOR
120
40
40W —A19 —CLEAR
1
PENDANT
1,4
LITHONIA
C- 2- 32- 120 —GEB
120
76
F032/741
2
CHAIN HUNG
2,3,4
IE
LITHONIA
C -2 -32- 120— GEB —EL
120
76
F032/741
2
CHAIN HUNG
J
UGHTOLIER
478BKX -40ZR1 C9X
120
50
50W MR16 FL
1
RECESSED
•
2,3,4
4,5
K
LITHONIA
WC -2 -17- 120 —TUBI
120
30
F017/741
2
VANITY
4,5
L
LITHONIA
6ELM2P
120
15
INCL W /FIXTURE
2
EMERGENCY
2,4
X
LITHONIA
LQM— S- 1— R- 120/277 —EL
120
5
LED W/FIXTURE
1
EXIT LIGHT
2,4
LIGHTING NOTES
1. FIXTURE PROVIDED BY OWNER, INSTALLED BY ELECTRICAL CONTRACTOR.
2. FIXTURE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.
3. PROVIDE SEISMIC BRACING AS NEEDED FOR CHAIN HUNG FIXTURES.
4. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL MOUNTING HARDWARE AS REQUIRED.
5. FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR.
ROUTE VIA
TO Sd TIMECLOCK
1H IN
ROUTE VIA
11MECLOCK
/H IN
CONTACTOR #1
WINDOW LTS
DISPLAY LTS --
0-1
1--0 —• B -18
1---0 + 13--16
H
H
CONTACTOR #2
SIGNAGE - 0
WINDOW 4--- -0 I
RECEPTS
WINDOW .1-0
RECEPTS
CONTRACTOR TO
PROVIDE ENCLOSURE
FOR CONTACTORS
CONTACTOR DETAIL
N.T.S.
16.104) REF ARCH FOR FIXTURE
QUANTITIES AND LOCATIONS
REF ARCH FOR FIXTURE
QUANTITIES AND LOCATIONS
Ka B-4
®1YP
B -4
B-4
DIVIDE 86 LIGHTS EVENLY
BETWEEN FOUR CIRCUITS.
ROUTE VIA CLP REF 4/E1.
21 25
FILE C Ply
PM* NO. •
Pint^ review approval is subject to errors and not
Approval of �_
the violation of any ad .r1/*!`� :. r . Receipt
of approved Reid ...✓ -
ay
Date:
City of Tu
BUILDING DIVISION
REVISIONS
No changes shalt be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees. i
•
B -4
r-- -- — T — — -- -- — -
ago-- - - - - --
ELECTRICAL SYMBOLS
LEGEND
LIGHTING KEYNOTES
(SYMBOLS APPLY ONLY WHEN USED ON DRAWINGS)
SYMBOL
DESCRIPTION
EXIT FIXTURE
(WALL MOUNTED /CEILING MOUNTED)
1=?" EMERGENCY LIGHT
$
SWITCH, SINGLE POLE
SOS SWITCH, OCCUPANCY SENSOR
RECEPTACLE, DUPLEX
❑ �
RECEPTACLE, QUADRUPLEX
NON—FUSED DISCONNECT
SURFACE MOUNTED PANELBOARD
Y TELEPHONE /DATA
O SPEAKER
MOTOR
NEU1RA IAID CIRCUIT, CONCEALED WHERE
H0 POSSIBLE, E INDICATES EXISTING
c WIRING
ABBREVIA11ONS
EF
GFI
WH
AFF
TYP
EXHAUST FAN
GROUND FAULT CIRCUIT INTERRUPTER
WATER HEATER
ABOVE FINISHED FLOOR
TYPICAL
16.100 NEW SWITCHBANK. PROVIDE A LIGHTING SWITCH FOR
EACH UGHTING CIRCUIT AND AS REQUIRED. ENGRAVE
EACH COVER PLATE AS FOLLOWS: SALES LTG., D.R.
LTG., CASEWORK LTG., CASH WRAP LTG., DISPLAY
WINDOW TRACK LTG., STOREFRONT LTG., SALES TRACK
LTG., SEE SWITCH BANK DETAIL
16.101 NEON SIGN, COORDINATE ELECTRICAL CONNECTION
REQUIREMENTS WITH OWNER AND LANDLORD. ROUTE
THROUGH 11MECLOCK.
16.102 PROVIDE WIREWAY AT +12' -0" AFF. USE GRAY COLOR
WIREMOLD ODS3(G3000) WITH DUPLEX RECEPTACLES
ON 3' -0" CENTERS. PROVIDE ALL HARDWARE AND
HANGERS. ALTERNATE BRANCH CIRCUIT TO
RECEPTACLES THROUGHOUT.
16.103 STORE FRONT SIGN: PROVIDE AND INSTALL
DISCONNECT IN CEILING SPACE. COORDINATE LOCATION
WITH SIGN INSTALLER.
16.104 INSTALL QUANTITY OF LIGHT FIXTURES AS INDICATED
ON ARCHITECTURAL DRAWINGS. INSTALL FIXTURES
ALONG ENURE LENGTH OF RACEWAY AS DIRECTED.
PROVIDE MATERIALS AS REQUIRED. SEE
ARCHITECTURAL DRAWINGS FOR SUSPENDED LIGHT AND
PIPE HANGER DETAILS.
16.105 INSTALL OWNER FURNISHED SPEAKERS. PENDANT
MOUNT AT +13' —O" AFF COORDINATE EXACT LOCATION
WITH ARCHITECT PRIOR TO ROUGH —IN. PROVIDE
LOOPED OR SERIES WIRING PLAN WITH 14 GAUGE
PLENUM RATED SPEAKER WIRE HIDDEN BEHIND THE
DRYWALL. PROVIDE 10' MINIMUM SPARE CABLE COILED
AT CASH WRAP FOR FINAL STEREO SYSTEM
TERMINATIONS. PROVIDEFINAL CONNECTION TO
SPEAKERS AND SOUND SYSTEM AS REQUIRED.
16.106 ROUTE CONDUIT CONCEALED UP TO STRUCTURE.
ROUTE TIGHT TO THE UNDERSIDE OF STRUCTURE TO
PANELBOARD.
GEN. DEMOLITION NOTES
B6 B8 B14 B6
O 0 0 0
0 0 0 0
O 0 0 0
Sa Sb Sc Sd
B19 B21 B23 B25
O 0 0 0
0 0 0 0
O 0 0 0
Se Sf Sg Sh
PROVIDE SWITCH LABELS, PER
ARCHITECTURAL
kEVIENNED
cCNFPA70_NEC
PR -3 08
SWITCHBANK DETAIL
N.T.S.
16.106
16.102)
B -4
NL
am)
B -4
NIGHT LIGHT FIXTURE, NL,
PROVIDE HOT UNSWITCHED
CONDUCTOR, TYP
PROVIDE LEUTRON
OCCUPANCY
SENSOR WITH NO
MORE THAN 30
MIN SETIING.
SWITCH VANITY
LIGHT WITH M0110N
SENSOR IN
EXHAUST FAN.
MOUNT FIXTURES IN
STOCKROOM AND
CORRIDOR +12' -0 ", TYP—\
..1
B -4
4 ?
16.105)TYP OF SPEAKERS
B-4
!._
+13' AFF, TYP OF
SALES AREA
LIGHTING PLAN
1/4" — 1'--0"
NL
1. REMOVE ALL EXISTING ELECTRICAL BRANCH CIRCUIT WIRING,
EQUIPMENT AND DEVICES UNLESS NOTED OTHERWISE.
LIGHTING GENERAL NOTES
1. ELECTRICAL CONTRACTOR SHALL COMMISION AND
DEMONSTRATE LIGHTING CONTROL SYSTEM FOR STORE
PERSONNEL SCHEDULE WITH STORE MANAGER WHEN
DEMONSTRATION SHALL TAKE PLACE.
2. COORDINATE WITH ARCHITECTUAL DRAWINGS FOR EXACT
LOCATION AND QUANTITY OF LIGHT FIXTURES.
CONDUIT/ WIRING NOTES
1. AC CABLING, MC CABLING, AND NONMETAWC SHEATHED
CABLING ARE NOT ALLOWED.
2. FLEXIBLE CONDUIT IS NOT ALLOWED, EXCEPT FOR WHIP (LESS
THAN 6 FEET IN LENGTH), CONNECTION TO MOTORS,
TRANSFORMERS, AND OTHER EQUIPMENT THAT PRODUCES
VIBRATIONS. USE ONLY GALVANIZED STEEL FLEX.
T
8-4
B -4
14
8
18
•
•
B
22
18
•
•
•
(16.101)
(16.103
MOUNT TO INTERMEDIATE
WINDOW FRAME (TYP)
0
wmmz
SOUTHCENTER MALL
SPACE # 2115
633 Soumerara
Swarm, WA 98188
MURPHY V[1i EYps
DAVID I. MURPHY, AIA
UM NB= AMU &MIsu
97 4171.1, YllEDICION 9Se 1
T: so6.3g. g8
F: so66.3g.9rfl
Se
vvw. Mminaurr.com
Harrison French and
Associates
809 S.W. "A" Street
Bentonville, AR 72712
(479) 273 -7780
fax (479) 273 -9436
EXPIRES: 07/22/08
PROJECT NUMBER: 05-08-02008
ZUMIEZ STORE NUMBER: 19
ISSUED FOR:
PRELIMINARY MALL
REVIEW
DATE:
02 -08 -08 PRELIMINARY MALL REVIEW
RECEIVED
CITY OF TUI:VVILA
MAR 2 8 2008
PERMIT CENTER
EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A
THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS
IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF
WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY
OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL
COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS
THAT OCCUR DUE TO FAILURE TO FAMIUARIZE WORKERS WITH
THIS KNOWLEDGE.
—21gs
SHEET TITLE:
LIGHTING
PLAN
SHEET NUMBER:
E1
(16.135)
2" CONDUIT AND 200A
FEEDER PROVIDED AND
INSTALLED BY LANDLORD.
MAIN DISCONNECT
PROVIDED BY LANDLORD.
2 "C,4#3/0,1 #6GR
3/4 "C,3#8,
1#10 GR
PANEL
A
TENANT SPACE
30KVA
XFMR
TIMECLOCK SCHEDULE
LABEL AS SHOWN
NO.
LOAD SERVED
MANUFACTURER
CATALOG NO.
MOTOR
VOLTS
CCT. NO.
CONTACT
INITIAL TIME
SETTING NOTES
TS1
STOREFRONT SIGN
STOREFRONT UGHTS
WINDOW RECEPTS
TORK
W300L
120V
3P
40A 120V
3PST
INDOOR, 7 DAY,24HR
NOTES: 1,2,3
NOTES:
1. INDICATED SWITCH SHALL BE HEAVY DUTY TYPE.
2. FURNISH AND INSTALL DISCONNECT SWITCHES WITH DUAL ELEMENT,
3. TIME DELAY FUSES AS EQUIPMENT MANUFACTURER REQUIRES.
SUSPEND XFMR
ABOVE
1 - 1 1/4"C,
4#3,1 #8GR,1 #8 IG
IBOND#8CU
TO
BUILDING
STEEL PER
NEC
PANEL
B
ONE -UNE KEYED NOTES:
NEW 200A 277/480V, 3PHASE PANEL TO BE
PROVIDED AS SCHEDULED.
NEW 30KVA TRANSFORMER TO BE SUSPENDED FROM
STRUCTURE AS SHOWN.
NEW TIME CLOCK PROVIDED BY ELECTRICAL
CONTRACTOR.
NEW CONTACTOR ENCLOSURE REF 3/E1.
NEW CURRENT LIMITING PANEL REF 4/E1.
NEW 100A 120/208V, 3PHASE PANEL TO BE
PROVIDED AS SCHEDULED.
NOTE
ALL EQUIPMENT IS NEW TO BE PROVIDED BY
ELECTRICAL CONTRACTOR AS SHOWN, UNLESS
NOTED OTHERWISE.
•
ONE -LINE DIAGRAM
N.T.S.
NEW PHONE
BOARD
16.125
l
0
USH- BUTTON,
+48" AFF
I.1
5
PANEL A
PANEL B
B
L_
TRANSFORMER TB
SUSPENDED ABOVE
A• HI
2
J
COORDINATE
CONNECTION OF NEW
VAV WITH MECHANICAL
1
A
SERVES: DISTRIBUTION
LOCATION: CORRIDOR
NEW PANELBOARD
200A MAIN LUG ONLY
3PH 4WIRE 480/277V
GROUND BAR
CK
LOAD SERVED
WIRE BRKR PL PHASE A
PHASE B
PHASE C
PL
BRKR
WIRE
LOAD SERVED
1
TRANSFORMER TB
8
50 3 6.26 1 5.00
5.47 1 5.00
4.86 1 5.00
7
9
11
13
15
17
SPACE
0.00 1 0.00
SPACE
SPACE
0.00 1 0.00
3
25
10
VAV1
2
4
6
SPACE
8
SPACE
10
SPACE
0.00 1 0.00
0.00 I o.00
SPACE
12
SPACE
SPACE
o.00 1 o.00
SPACE
14
SPACE
16
0.00 1 0.00
SPACE
18
PER NEC ARTICLE 220
TOTAL
TOTAL LOAD
FEEDER LOAD
11.26
40.65
31.59
33.04
10.47
9.86
37.79
35.60
KVA
KVA
38.04
39.78
KVA
AMPS
AMPS
AMPS
(L) INDICATES LOCKING DEVICE
B ( 100A MAIN LUG ONLY
SERVES: DISTRIBUTION NEW PANELBOARD PHFZ€- ZQB/f2w
LOCATION: CORRIDOR GROUND BAR
ISOLATED GROUND BAR
CK
LOAD SERVED
WIRE
BRKR
PL
PHASE A
PHASE B
PHASE C
PL
BRKR
WIRE
LOAD SERVED
CK
1
STOCK RECEPTS
12
20
1
0.54 1 0.49
31.59
N.E.C. DEMAND
1
20
12
STOCKROOM LTS
2
3
SALES RECEPTS
12
20
1
7.24
0.72 0.43
1
20
12
EMER /EXIT /NL (L)
4
5
WINDOW RECEPTS
12
20
1
0.72 1 0.18
1
20
12
11MECLOCK /CONY.
6
7
WINDOW RECEPTS
12
20
1
0.72 1 1.31
1
20
12
SALES LTS
8
9
SALES RECEPTS
12
20
1
0.54 1 0.12
1
20
12
DRESSING RM LTS
10
11
SALES RECEPTS
12
20
1
0.36 1 0.00
1
20
--
SPARE
12
13
CASHWRAP IG
12
20
1
0.36 1 0.44
1
20
12
CASHWRAP LTS
14
15
CASHWRAP
12
20
1
0.36 T CCI
1
20
12
STOREFRONT LTS
16
17
WATER HEATER (L)
12
20
1
1.50 1 0.90
1
20
12
DISPLAY LTS
18
19
PLUGMOLD SALES
12
20
1
1.20 1 0.00
1
20
--
SPARE
20
21
PLUGMOLD SALES
12
20
1
1.20 1 1.20
1
20
12
SIGNAGE
22
23
PLUGMOLD SALES
12
20
1
1.20 1 0.00
1
20
--
SPARE
24
25
PLUGMOLD SALES
12
20
1
1.20 1 0.00
1
20
---
SPARE
26
27
SPARE
--
20
1
0.00 0.00
1
20
---
SPARE
28
29
SPARE
--
20
1
0.00 1 0.00
1
20
--
SPARE
30
31
SPARE
--
20
1
0.00 0.00
1
20
--
SPARE
32
33
SPARE
--
20
1
0.00 1 0.00
1
20
--
SPARE
34
35
SPARE
--
20
1
0.00 1 0.00
1
20
--
SPARE
36
37
SPARE
--
20
1
0.00 0.00
1
20
--
SPARE
38
39
SPARE
--
20
1
0.00 1 0.00
1
20
--
SPARE
40
41
SPARE
--
20
1
0.00 1 0.00
1
20
--
SPARE
42
TOTAL
TOTAL LOAD
PER NEC ARTICLE 220 FEEDER LOAD
6.26
5.17
4.86
KVA
AMPS
AMPS
AMPS (L) INDICATES LOCKING DEVICE
52.17
43.08
40.50
16.29
KVA
KVA
45.27
17.66
49.08
LOW VOLTAGE GEN. NOTES
POWER KEYNOTES
1. ALL LOW VOLTAGE WIRING SHALL BE ROUTED IN CONDUIT.
GEN. DEMOLITION NOTES
1. REMOVE ALL EXISTING ELECTRICAL BRANCH CIRCUIT WIRING,
EQUIPMENT AND DEVICES UNLESS NOTED OTHERWISE
CONDUIT/ WIRING NOTES
1. AC CABLING, MC CABUNG, AND NONMETAWC SHEATHED
CABLING ARE NOT ALLOWED.
2. FLEXIBLE CONDUIT IS NOT ALLOWED, EXCEPT FOR WHIP (LESS
THAN 6 FEET IN LENGTH), CONNECTION TO MOTORS,
TRANSFORMERS, AND OTHER EQUIPMENT THAT PRODUCES
VIBRATIONS. USE ONLY GALVANIZED S Il±L FLEX.
CONNECTED LOADS
LOAD
LIGHTS
RCEPT.
RCEPT.
REFRIG.
KITCHEN
MISC.
NI
HVAC
TOTAL
CONNECTED LOAD (KVA)
5.79
9.12
0.00
0.00
0.00
0.18
1.50
15.00
31.59
N.E.C. DEMAND
125%
100%
50%
100%
65%
100%
100%
100%
FEEDER LOAD (KVA)
7.24
9.12
0.00
0.00
0.00
0.18
1.50
15.00
33.04
WH, MOUNT ABOVE
CEILING, COORDINATE
LOCA11ON WITH PLUMBING
16.121 SURFACE MOUNTED JUNCTION BOX FOR HARD -WIRED
CASEWORK IGHT FIXTURE. COORDINATE EXACT
LOCATION WITH ARCHITECT. PROVIDE WALL SWITCH AT
SWITCH BANK LOCATION FOR ON /OFF CONTROL OF
LIGHT FIXTURE NOTED. RUN ALL ASSOCIATED CONDUIT
SURFACE MOUNTED ON FLOOR BENEATH CASEWORK.
WIRE LIGHT FIXTURE F.B.O.I.C.
16.123 POKE - THROUGH LOCATION INDICATED IS
DIAGRAMMATIC. LOCATE POKE - THROUGH DEVICE
BENEATH CASEWORK. COORDINATE EXACT LOCATION
WITH ARCHITECT PRIOR TO COMMENCEMENT OF WORK.
16.124 PROVIDE DUPLEX RECEPTACLE IN WINDOW BASE.
CONCEAL CONDUIT IN WINDOW BASE. PROVIDE BLACK
OUTLET WITH BLACK COVERPLATE ROUTE POWER
THROUGH TIMECLOCK. TYPICAL AT DISPLAY WINDOWS
UNLESS NOTED OTHERWISE.
16.125 NEW TELEPHONE TERMINAL BOARD. INSTALL
4'X4'X3/4" FIRE TREATED PLYWOOD BACKBOARD WITH
#6 CU GND. WIRE TO NEAREST BUILDING GROUND
ELECTRODE. COORDINATE INSTALL WITH LANDLORD.
16.127 PROVIDE EDWARDS MINIATURE LUNGEN 115 SERIES
BUZZER IN CASHWRAP. PROVIDE BUZZER,
TRANSFORMER, PUSHBUTTON, CONDUCTORS, AND ALL
CONNECTIONS REQUIRED FOR A COMPLETE FUNCTIONAL
SYSTEM. RUN LOW VOLTAGE WIRING, CONCEALED IN
CLG. SPACE OR IN WALL CAVITY, BACK TO DOOR
PUSHBUTTON.
16.130 PROVIDE DUPLEX RECEPTACLE MOUNTED TO SOFFIT
ABOVE DISPLAY WINDOW. COORDINATE EXACT
LOCA11ON WITH ARCHITECT PRIOR TO INSTALLATION.
ROUTE POWER THROUGH 11MECLOCK.
16.131 RUN (2) 1" CONDUITS OVERHEAD TIGHT TO UNDERSIDE
OF STRUCTURE. EXTEND CONDUITS TO TELEPHONE
TERMINAL BOARD. SEE " CASHWRAP" DETAIL
16.134 1" CONDUIT STUB TO CEILING SPACE FOR VIDEO,
STEREO, AND CHIME LV. CABLE TO CASEWORK, VERIFY
LOCATION PRIOR TO ROUGH IN.
16.135 ILLUMINATED BUZZER PUSH - BUTTON AT +48" AFF
WITH W C. STUB TO CEILING SPACE. LABEL BUZZER
"ZUMIEZ" WITH PLASTIC SIGN.
REVIEWED LIAANCE
CODE COMPLIANCE
70 - NEC
APR - 3 20ra$
Tukwila
BUILD NG DIVISION
-r1111111
ALL UNDERGROUND
CONDUITS TO BE 1" I I I I
(16.131)
ROUTE ALL CONDUITS (16.134)
FOR CASH WRAP IN (16.123
CABINET, TYP OF 5
(16.127,
Q
CASH
WRAP
SWITCH CASE LIGHTS
WITH PENDANT UGHTING
ABOVE.
SWITCHED JUNCTION
16.121 BOX FOR CASE
LIGHTING
111
ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE,
OPERATIONAL FIRE ALARM SYSTEM IN ACCORDANCE WITH
ALL CODE AND MANUFACTURING REQUIREMENTS,
INCLUDING DEVICES REQUIRED BY LOCAL AHJ AND MALL
FINAL CONNECTION FROM THE TENANT'S FIRE ALARM
SYSTEM TO THE MALL'S FIRE ALARM SYSTEM WILL BE
BY LANDLORD'S CONTRACTOR AT TENANTS EXPENSE.
POWER PLAN
1 /4" = 1'--0"
16.130
COORDINATE
LOCATION WITH
OWNER, TYP OF 4
16.130
WIN
16.124
16.124
■R
IR
RR
1f,
Is
IR
EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A
THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS
IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF
WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBIUTY
OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL
COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS
THAT OCCUR DUE TO FAILURE TO FAMIUARIZE WORKERS WITH
THIS KNOWLEDGE.
zumez
SOUTHCENTER MALL
SPACE ft 2115
633 S017111001TER
SEATr,la, WA 98188
MURPHY VAREYPs
DAVID J. MURPHY, AIA
um riu=Amax Brian
Bums, Tomas* 95=
T: 106.541.9875
F: sa6.5P • 9ry
E: vvv. MvascYAl
�i
Harrison French and
Associates
809 S.W. "A" Street
Bentonville, AR 72712
(479) 273 -7780
fax (479) 273 -9436
EXPIRES: 07/22/08
,ce
RECEIVED
CITY OF TUKWILA
MAR 2 81008
PERMIT CENTER
PROJECT NUMBER: 05 -08 -02008
ZUMIEZ STORE NUMBER: 19
ISSUED FOR:
PRELIMINARY MALL
REVIEW
DATE:
02 -08 -08 PRELIMINARY MALL REVIEW
SHEET TITLE:
POWER
PLAN
SHEET NUMBER:
E2
FLOOR
Project Address
ZUMIEZ- SOUTHCENTER MALL
Date
3/10/2008
The follow ing information is necessary to check a fighting permit application for compliance w ith the lighting requirements in the
2004 Washington State Nonresidential Energy Code,
Applicability
(yes, no, n.a.)
Code
Section Component
Information Required
Location Building Department
on Flans Notes
LIGHTING CONTROLS (Section 1513)
no
Yes
n. a.
n. a.
n. a.
yes
n. a.
n.a.
yes
yes
n. a.
1513.1
1513.2
1513.3
1513.4
1513.6
Local controVaccess
Schedule w ith type, indicate locations
Area controls
Maximum limit per sw itch
El
Daylight zone control
vertical glazing
Schedule w ith type and features, indicate locations
Indicate vertical glazing on plans
overhead glazing
Cis play /exhib /special
Indicate overhead glazing on plans
Indicate separate controls
El
Exterior shut -off
Schedule w ith type and features, indicate location
(a) timer w /backup
Indicate location
(b) photocell.
Indicate location
Inter. auto shut -off
Indicate location
1513.6.1
(a) occup. sensors
Schedule w ith type and locations
El.
1513.6.2
1513.7
(b) auto. sw itches
Schedule w ith type and features (back-up, override capability
Indicate size of zone on plans
E2
Connissioning
Indicate requirements for lighting controls corrrrissioning
yes
Lighting Sum. Form
Completed and attached.
Schedule w ith fixture types,
lamps, ballasts, w atts per fixture
E3
n.a. ® 1437
Bec motor efficiency
MECH -MOT or Equipment Schedule w ith hp, rpm, efficiency
If "no" is circled for any question, provide explanation:
Local lighting control for the retail space lighting is not required per exception #1 of section 1513.1.
(2) 1" CONDUITS TO CASHWRAP.
(1) FOR DATA /VOICE CABLING
AND (1) SPARE.
TELE.BKBD
ROUTE CONDUITS
TIGHT TO UNDERSIDE
OF STRUCTURE BELOW.
COLUMN /WALL
TOE KICK
Lighting Summary'
Project Info
Project Address ZUMIEZ- SOUTHCENTER MALL
Date
3/10/2008
Applicant Name: ZUMIE Z
Applicant Address: TUKWILA, WA
Applicant Phone:
For Building Department Use
Project Description
❑ New Building ❑ Addition 0 Alteration ['Plans Induded
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
0 Prescriptive 0 Lighting Pow er Allow ance 0 Systems Analysis ❑ Gear
(See Qualification Checklist (over). Indicate Prescriptive & IPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
❑ No changes are being made to the lighting
❑ Less than 60% of the fixtures new , installed wattage not increased, & space use not changed.
Maximum Allowed Lighting Wattage (Interior)
Location
(floor /room no.)
Occupancy Description
A flow ed
Watts per ft2
Area in ft2
Allowed x Area
TENANT SPACE
RETAIL
1.50
2668.0
4002.0
STORAGE
STORAGE
0.50
467.0
233.5
** From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts
Notes:
1. Use manufacturer's fisted maximum input w attage. For hard -wired ballasts only,
the default table in the NREC Technical Reference Manual may also be used
2. Include exit lights unless less than 5 w atts per fixture.
3. List all fixtures. For exempt lighting. not exception and leave Watts /Fixture blank.
Number of Watts / Watts
Fixtures Fixture Proposed
Proposed Lighting Wattage (Interior)
Location
(floor /room no.)
4235.5
Fixture Description
SALES
TYPE A - PENDANT
8
218.0
1744.0
SALES
TYPE B - SHOWCASE DISPLAY (EXEMPT)
SALES
TYPE C - CASH WRAP PENDANT
11
40.0
490.0
SALES
TYPE D - PORTABLE PLUG IN DISPLAY (EXERT)
SALES
TYPE D1 -- PORTABLE PLUG IN DISPLAY (EXEMPT)
SALES
TYPE H - DRESSING RM PENDANT
3
40.0
120.0
STORAGE
TYPE I -- 4 FT STRIP
5
76.0
380.0
CORRIDOR
TYPE IE - 4 FT STRIP
2
76.0
152.0
SALES
TYPE K -- VANITY LIGHT
1
30.0
30.0
SALES
TYPE L - EMERGENCY FIXTURE (EXEMPT)
SALES
TYPE X - EXIT LIGHT (EXEMPT)
Total Proposed Watts may not exceed Total Allow ed Watts for Interior
Total Proposed Watts
REVIEWED FOR
CODE COMPLIANCE
NFPA 70 - NEC
APR - 3 2008
City flf Tukwila
B ILDING D - ION
2866.0
1" CONDUIT STUB TO BOTTOM OF STRUCTURE FOR VIDEO, STEREO
AND BUZZER LV. CABLE. STUB TO BENEATH CASEWORK.
REG. #1
REG. #2
CASH WRAP DETAIL
N.T.S.
1" CONDUIT
FOR DATA/VOICE
CABLING
E
1° DATA CONDUIT
1" VOICE CONDUIT
C7-)
TYP
RECEIVED
CITY OF TUKVVILA
MAR 2 8 2008
PERMIT CENTER
EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A
THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS
IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF
WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY
OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL
COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS
THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH
THIS KNOWLEDGE.
zumez
SOUTSCENTER MALL
SPACE # 2115
6 $rn acaw e
Swarm, WA 98188
MURPHY VYPs
DAVID J. MURPHY, AIA
uoi Mon draw Gamut
BUM; Y1ualCratr glint
7: lo6.S4t•9�lS
F: m6.3 . 9117
E: rvv. ]fom:Yaur.aat
Harrison French and
Associates
809 S.W. "A" Street
Bentonville, AR 72712
(479) 273 -7780
fax (479) 273 -9436
EXPIRES: 07/22/08
PROJECT NUMBER: 05.08.02008
ZUMIEZ STORE NUMBER: 19
ISSUED FOR:
PRELIMINARY MALL
REVI Ew
DATE:
02 -08 -08 PRELIMINARY MALL REVIEW
SHEET TITLE:
ELECTRI CAL
DETAILS
SHEET NUMBER:
E3
CASHWRAP DETAIL GENERAL NOTES
1.
DETAIL IS DIAGRAMMATIC. REGISTER LOCATIONS SHOWN ON PLANS MAY DIFFER FROM DETAIL.
2.
SEE POWER PLAN FOR CASEWORK LIGHTING ELECTRICAL REQUIREMENTS.
3.
SEE POWER PLAN FOR ADDITIONAL INFORMATION.
CASHWRAP DETAIL KEYED NOTES
1.
PROVIDE JUNCTION BOX BENEATH CASEWORK ACCESS PANEL, ADJACENT TO 4 -PLEX, FOR ROUTING
OF NETWORK, DATA, AND TELEPHONE CABLING.
1" CONDUIT STUB TO BOTTOM OF STRUCTURE FOR VIDEO, STEREO
AND BUZZER LV. CABLE. STUB TO BENEATH CASEWORK.
REG. #1
REG. #2
CASH WRAP DETAIL
N.T.S.
1" CONDUIT
FOR DATA/VOICE
CABLING
E
1° DATA CONDUIT
1" VOICE CONDUIT
C7-)
TYP
RECEIVED
CITY OF TUKVVILA
MAR 2 8 2008
PERMIT CENTER
EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A
THOROUGH KNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS
IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF
WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY
OF PERFORMING HIS WORK PROPERLY. NO ADDITIONAL
COMPENSATION SHALL BE ALLOWED BECAUSE OF CONDITIONS
THAT OCCUR DUE TO FAILURE TO FAMILIARIZE WORKERS WITH
THIS KNOWLEDGE.
zumez
SOUTSCENTER MALL
SPACE # 2115
6 $rn acaw e
Swarm, WA 98188
MURPHY VYPs
DAVID J. MURPHY, AIA
uoi Mon draw Gamut
BUM; Y1ualCratr glint
7: lo6.S4t•9�lS
F: m6.3 . 9117
E: rvv. ]fom:Yaur.aat
Harrison French and
Associates
809 S.W. "A" Street
Bentonville, AR 72712
(479) 273 -7780
fax (479) 273 -9436
EXPIRES: 07/22/08
PROJECT NUMBER: 05.08.02008
ZUMIEZ STORE NUMBER: 19
ISSUED FOR:
PRELIMINARY MALL
REVI Ew
DATE:
02 -08 -08 PRELIMINARY MALL REVIEW
SHEET TITLE:
ELECTRI CAL
DETAILS
SHEET NUMBER:
E3
SEC11ON 16A: ELECTRICAL
16A 1 GENERAL INSTRUCTIONS
16A 1 -1 GENERAL REQUIREMENTS
ALL REQUIREMENTS UNDER DIVISION 1 AND THE GENERAL AND
SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS APPLY TO THIS
SECTION AND DIVISION. WHERE THE REQUIREMENTS OF THIS SECTION
AND DIVISION EXCEED THOSE OF DIVISION 1, THIS SECTION AND
DIVISION TAKE PRECEDENCE. BECOME THOROUGHLY FAMILIAR WITH ALL
THEIR CONTENTS AS TO REQUIREMENTS THAT AFFECT THIS DIVISION,
SEC11ON OR BOTH. WORK REQUIRED UNDER THIS DIVISION INCLUDES
ALL MATERIAL, EQUIPMENT, APPUANCES, AND LABOR REQUIRED TO
COMPLETE THE ENTIRE ELECTRICAL SYSTEM AS REQUIRED BY THE
DRAWINGS AND SPECIFICATIONS, OR REASONABLY INFERRED TO BE
NECESSARY TO FACILITATE EACH SYSTEM'S FUNCTIONING AS IMPLIED BY
THE DESIGN AND THE EQUIPMENT SPECIFIED.
THE SPECIFICATIONS AND DRAWINGS FOR THE PROJECT ARE
COMPLEMENTARY, AND PORTIONS OF THE WORK DESCRIBED IN ONE,
SHALL BE PROVIDED AS IF DESCRIBED IN BOTH, IN THE EVENT OF
DISCREPANCIES, NOTIFY THE ENGINEER AND REQUEST CLARIFICATION
PRIOR TO PROCEEDING WITH THE WORK INVOLVED.
DRAWINGS ARE GRAPHIC REPRESENTATIONS OF THE WORK UPON WHICH
THE CONTRACT IS BASED. THEY SHOW THE MATERIALS AND THEIR
RELATIONSHIP TO ONE ANOTHER, INCLUDING SIZES, SHAPES, LOCATIONS,
AND CONNECTIONS. THEY ALSO CONVEY THE SCOPE OF WORK,
INDICATING THE INTENDED GENERAL ARRANGEMENT OF THE EQUIPMENT,
FIXTURES, OUTLETS AND CIRCUITS WITHOUT SHOWING ALL OF THE
EXACT DETAILS AS TO ELEVATIONS, OFFSETS, CONTROL LINES, AND
OTHER INSTALLATION REQUIREMENTS. USE OF THE DRAWINGS AS A
GUIDE WHEN LAYING OUT THE WORK AND TO VERIFY THAT MATERIALS
AND EQUIPMENT WILL FIT INTO THE DESIGNATED SPACES, AND WHICH,
WHEN INSTALLED PER MANUFACTURES' REQUIREMENTS, WILL ENSURE A
COMPLETE, COORDINATED, SATISFACTORY AND PROPERLY OPERATING
SYSTEM.
SPECIFICATIONS DEFINE THE QUALITATIVE REQUIREMENTS FOR
PRODUCTS, MATERIALS, AND WORKMANSHIP UPON WHICH THE
CONTRACT IS BASED.
16A 1 -2 PRE —BID SITE INSPECTION
PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME
FULLY INFORMED OF CONDITIONS UNDER WHICH THE WORK I5 TO BE
DONE. FAILURE TO DO SO WILL NOT BE CONSIDERED SUFFICIENT
JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER
AND ABOVE THE CONTRACT PRICE.
16A 1 -3 MATERIAL AND WORKMANSHIP
PROVIDE ALL MATERIAL AND EQUIPMENT NEW AND IN FIRST CLASS
CONDITION. PROVIDE MARKINGS OR A NAMEPLATE FOR ALL MATERIAL
AND EQUIPMENT IDENTIFYING THE MANUFACTURER AND PROVIDING
SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY.
ALL WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY
EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL,
PROVIDE COMMERCIAL SPECIFICATION GRADE QUALITY FOR ALL
MATERIALS AND EQUIPMENT. UGHT DUTY AND RESIDENTIAL TYPE
EQUIPMENT WILL NOT BE ACCEPTABLE. PROVIDE ALL HOISTS,
SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT
REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK. STORE
AND MAINTAIN MATERIAL AND EQUIPMENT IN CLEAN CONDITION, AND
PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE.
FURNISH ONLY MATERIAL AND EQUIPMENT THAT ARE USTED, LABELED,
OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL),
WHENEVER ANY LISTING OR LABELING EXISTS FOR THE TYPES OF
MATERIAL AND EQUIPMENT SPECIFIED.
16A 1 -4 COORDINATION
COORDINATE ALL WORK WITH OTHER DIVISIONS AND TRADES SO THAT
THE VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS ARE
INSTALLED AT THE PROPER TIME, FIT THE AVAILABLE SPACE, AND
ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. REFER TO ALL
DRAWINGS, INCLUDING, BUT NOT UMITED TO, CIVIL, ARCHITECTURAL,
5
TRUCTIRA MECHANICAL AND PLUMBING, AND TO RELEVANT
L-,
L, ,
EQUIPMENT SUBMITTALS AND SHOP DRAWINGS TO DETERMINE THE
EXTENT OF CLEAR SPACES. MAKE ALL OFFSETS REQUIRED TO CLEAR
EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO
FACILITATE CONCEAUNG RACEWAYS IN THE MANNER ANTICIPATED IN
THE DESIGN. PROVIDE MATERIALS MTh TRIM THAT WILL FIT PROPERLY
THE TYPES OF CEIUNG, WALL, OR FLOOR FINISHES ACTUALLY
INSTALLED.
16A 1 -5 DEFINITIONS
WHENEVER USED IN THESE SPECIFICATIONS OR DRAWINGS, THE
FOLLOWING TERMS SHALL HAVE THE INDICATED MEANINGS:
FURNISH: TO SUPPLY AND DELIVER TO THE PROJECT SITE READY FOR
UNLOADING, UNPACKING, ASSEMBLING, INSTAWNG AND SIMILAR
OPERATIONS.
INSTALL TO PERFORM ALL OPERATIONS AT THE PROJECT SITE,
INCLUDING, BUT NOT LIMITED TO, AND AS REQUIRED: UNLOADING,
UNPACKING, ASSEMBLING, ERECTING, PLACING, ANCHORING, APPLYING,
WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING,
TESTING, COMMISSIONING, STARTING UP AND SIMILAR OPERATIONS,
COMPLETE, AND READY FOR THE INTENDED USE."
PROVIDE: TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE
INTENDED USE."
FURNISHED BY OWNER (OR OWNER— FURNISHED) OR FURNISHED BY
OTHERS: "AN ITEM FURNISHED BY THE OWNER OR UNDER OTHER
DIVISIONS OR CONTRACTS, AND INSTALLED UNDER THE REQUIREMENTS
OF THIS DIVISION, COMPLETE AND READY FOR THE INTENDED USE,
INCLUDING ALL ITEMS INCIDENTAL TO THE WORK NECESSARY FOR
PROPER INSTALLATION AND OPERATION. INCLUDE THE INSTALLATION
UNDER THE WARRANTY REQUIRED BY THIS DIVISION.
ENGINEER: WHERE REFERRED TO IN THIS DIVISION, "ENGINEER" IS THE
ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK
UNDER THIS DIVISION, AND IS A CONSULTANT TO, AND AN AUTHORIZED
REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL
AND /OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION,
IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE
ENGINEER, IN ADDITION TO INVOLVEMENT BY, AND
OBLIGATIONS TO THE "ARCHITECT".
AHJ: THE LOCAL CODE AND /OR INSPECTION AGENCY (AUTHORITY)
HAVING JURISDICTION OVER THE WORK.
NRTL: NATIONALLY RECOGNIZED TESTING LABORATORY, AS DEFINED AND
USTED BY OSHA IN 29 CFR 1910.7 (E.G., UL, ETL, CSA), AND
ACCEPTABLE TO THE AHJ OVER THIS PROJECT.
THE TERMS "APPROVED EQUAL ", "EQUIVALENT", OR "EQUAL" ARE USED
SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO
THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER
SPECIFIED ". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR
BOTH, BY AN NRTL., AND ACCEPTABLE TO THE AHJ OVER THIS
PROJECT.
16A 1 -6 DIMENSIONS AND LAYOUTS
DRAWINGS ARE SCHEMATIC IN NATURE, SHOW THE VARIOUS
COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND
ATTEMPT TO INDICATE HOW THEY SHALL BE INTEGRATED WITH OTHER
PARTS OF THE WORK. FIGURED DIMENSIONS TAKE PRECEDENCE TO
SCALED DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB
MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF OTHER TRADES,
AND BY REVIEWING ALL CONTRACT DOCUMENTS. CORRECT ERRORS
THAT COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND
INSPECTION, AT NO ADDITIONAL COST TO THE OWNER.
16A 1 -7 ORDINANCES AND CODES
COMPLY, AT A MINIMUM, NATIONAL FIRE PROTECTION ASSOCIATION
(NFPA) CODES, STATE AND LOCAL BUILDING CODES, AND ALL OTHER
APPUCABLE CODES AND ORDINANCES FOR PERFORMANCE,
WORKMANSHIP, EQUIPMENT, AND MATERIALS. ADDITIONALLY, COMPLY
WITH RULES AND REGULATIONS OF PUBUC U11U11ES AND MUNICIPAL
DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES.
WHERE CONFUCTS BETWEEN VARIOUS CODES, ORDINANCES, RULES, AND
REGULATIONS EXIST, COMPLY WITH THE MOST STRINGENT. WHEREVER
REQUIREMENTS OF THESE SPECIFICATIONS, DRAWINGS, OR BOTH, EXCEED
THOSE OF THE ABOVE ITEMS, THE REQUIREMENTS OF THESE
SPECIFICATIONS, DRAWINGS, OR BOTH, SHALL GOVERN. CODE
COMPUANCE, AT A MINIMUM, I5 MANDATORY. CONSTRUE NOTHING IN
THESE CONSTRUCTION DOCUMENTS AS PERMITTING WORK NOT IN
COMPLIANCE, AT A MINIMUM, WITH THESE CODES.
BRING ALL CONFUCTS OBSERVED BETWEEN CODES, ORDINANCES, RULES,
REGULATIONS AND THESE DOCUMENTS TO THE ENGINEER'S ATTENTION
FOR FINAL RESOLUTION. CONTRACTOR WILL BE HELD RESPONSIBLE FOR
ANY VIOLATION OF THE LAW.
PROVIDE AND MAINTAIN ALL NECESSARY SIGNAL UGHTS AND GUARDS
FOR THE SAFETY OF THE PUBUC. OBTAIN AND PAY FOR ALL PERMITS
FOR WORK IN THIS DIVISION.
16A 1 -8 MANUFACTURERS
IN OTHER ARTICLES WHERE USTS OF MANUFACTURERS ARE
INTRODUCED, THE FOLLOWING REQUIREMENTS APPLY TO PRODUCT
SELECTION:
A. MANUFACTURERS: SUBJECT TO COMPUANCE WITH REQUIREMENTS,
PROVIDE PRODUCTS BY ONE OF THE MANUFACTURERS SPECIFIED.
WHERE A UST IS PROVIDED, MANUFACTURERS ARE LISTED
ALPHABETICALLY AND NOT IN ACCORDANCE WITH ANY RANKING OR
PREFERENCE.
16A 1 -9 SUBMITTALS
ASSEMBLE AND SUBMIT TO THE ARCHITECT, FOR ENGINEER'S REVIEW,
MANUFACTURERS' PRODUCT LITERATURE FOR MATERIAL AND EQUIPMENT
TO BE FURNISHED, INSTALLED, OR BOTH, UNDER THIS DIVISION,
INCLUDING SHOP DRAWINGS, MANUFACTURERS' PRODUCT DATA AND
PERFORMANCE SHEETS, SAMPLES, AND OTHER SUBMITTALS REQUIRED
BY THIS DIVISION. PROVIDE THE NUMBER OF SUBMITTALS REQUIRED BY
DIVISION 1. BEFORE SUBMITTING, VERIFY THAT ALL MATERIALS AND
EQUIPMENT SUBMITTED ARE MUTUALLY COMPATIBLE AND SUITABLE FOR
THE INTENDED USE, AND FIT THE AVAILABLE SPACES, AND ALLOW
AMPLE AND CODE— REQUIRED ROOM FOR ACCESS AND MAINTENANCE.
SUBMITTALS SHALL CONTAIN THE FOLLOWING INFORMATION.
SUBMITTALS NOT SO IDENTIFIED WILL BE RETURNED TO THE
CONTRACTOR WITHOUT ACTION:
B.
C.
D.
THE PROJECT NAME.
APPLICABLE SPECIFICATION SECTION AND PARAGRAPH.
THE SUBMITTAL DATE.
THE CONTRACTOR'S STAMP, WHICH SHALL CERTIFY THAT THE
STAMPED DRAWINGS HAVE BEEN CHECKED BY THE CONTRACTOR,
COMPLY WITH THE DRAWINGS AND SPECIFICATIONS, AND HAVE
BEEN COORDINATED WITH OTHER TRADES.
TRANSMIT SUBMITTALS AS EARLY AS REQUIRED TO SUPPORT THE
PROJECT SCHEDULE. ALLOW FOR TWO WEEKS ENGINEER REVIEW 11ME,
PLUS MAILING TIME, PLUS A DUPUCATION OF THIS TIME FOR
RESUBMITTALS, IF REQUIRED. TRANSMIT SUBMITTALS AS SOON AS
POSSIBLE AFTER NOTICE TO PROCEED AND BEFORE CONSTRUCTION
STARTS. THE ENGINEER'S SUBMITTAL REVIEWS WILL NOT RELIEVE THE
CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS,
DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR OMITTING COMPONENTS
OR FITTINGS; OR COORDINATING ITEMS WITH ACTUAL BUILDING
CONDITIONS.
16A 1 -10 ADJUSTING, AUGNING AND TESTING
ADJUST, AUGN, AND TEST ALL ELECTRICAL EQUIPMENT ON THIS
PROJECT PROVIDED UNDER THIS DIVISION AND ALL ELECTRICAL
EQUIPMENT FURNISHED BY OTHERS FOR INSTALLATION OR WIRING
UNDER THIS DIVISION, FOR PROPER OPERATION.
TEST ALL SYSTEMS AND EQUIPMENT ACCORDING TO THE REQUIREMENTS
IN NETA ATS (LATEST EDITION).
MAINTAIN THE FOLLOWING ON THE PROJECT PREMISES AT ALL 11MES: A
TRUE RMS READING VOLTMETER, A TRUE RMS READING AMMETER, AND
A MEGOHMMETER INSULATION RESISTANCE TESTER. PROVIDE TEST
DATE READINGS AS REQUESTED OR AS REQUIRED BY THE ENGINEER.
16A 1 -11 OPERATION AND MAINTENANCE INSTRUCTIONS
SUBMIT TO THE ARCHITECT, FOR ENGINEER'S REVIEW, COPIES EACH OF
OPERATIONS AND MAINTENANCE INSTRUCTION MANUALS,
APPROPRIATELY BOUND INTO
MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING,
REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS
ACTUALLY INSTALLED PROVIDE THE NUMBER OF SUBMITTALS REQUIRED
BY DIVISION 1 AND INCLUDE AT A MINIMUM THE FOLLOWING
INFORMATION:
A. MANUFACTURERS' CATALOG AND PRODUCT DATE SHEETS
B. WIRING DIAGRAMS
C. MAINTENANCE INSTRUCTIONS
D. OPERATING INSTRUCTIONS
E. PARTS LISTS
F. TEST REPORTS AS DEFINED IN NETA ATS FOR THE SYSTEMS AND
EQUIPMENT PROVIDED AND INSTALLED UNDER THIS CONTRACT
G. NAMES, ADDRESSES, TELEPHONE NUMBERS, AND E —MAIL
ADDRESSES OF LOCAL CONTACTS FOR WARRANTY SERVICES
AND SPARE PARTS
SUBMIT MANUALS PRIOR TO REQUESTING THE FINAL PUNCH UST AND
BEFORE ANY REQUESTS FOR SUBSTANTIAL COMPLETION. ALSO PROVIDE
ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATIONS TO OWNER'S
REPRESENTATIVE AT THE COMPLETION OF, AND BEFORE FINAL
ACCEPTANCE OF, THE WORK.
16A 1 -12 SYSTEM START UP
PRIOR TO STARTING UP THE ELECTRICAL SYSTEMS, CHECK ALL
COMPONENTS AND DEVICES, LUBRICATE ITEMS ACCORDINGLY, AND
TIGHTEN SCREWS AND BOLTS FOR CONNECTORS AND TERMINALS
ACCORDING TO MANUFACTURER'S PUBLISHED TORQUE- 11GHTENING
VALUES. IF MANUFACTURE'S TORQUE VALUES ARE NOT INDICATED, USE
THOSE SPECIFIED IN UL 486A. ADJUST TAPS ON EACH TRANSFORMER
FOR RATED SECONDARY VOLTAGE. CHECK AND RECORD BUILDING'S
SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS, GROUNDING
RESISTANCE, AND PROPER PHASING. BALANCE ALL SINGLE —PHASE
LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT
CONNECTIONS UNTIL BALANCE IS ACHIEVED. DO NOT TYPE UP FINAL
PANELBOARD DIRECTORIES UNTIL ALL RE— BALANCING AND
REDISTRIBUTION OF CIRCUITS ARE COMPLETE. REPLACE ALL
BURNED —OUT LAMPS AND LAMPS USED FOR TEMPORARY CONSTRUCTION
UGHTING IN PERMANENT LIGHT FIXTURES. AFTER ALL SYSTEMS HAVE
BEEN INSPECTED AND ADJUSTED, CONFIRM ALL OPERATING FEATURES
REQUIRED BY THE DRAWINGS AND SPECIFICATIONS AND MAKE FINAL
ADJUSTMENTS AS NECESSARY.
16A 1 -13 WARRANTIES
WARRANT EACH SYSTEM AND EACH ELEMENT THEREOF AGAINST ALL
DEFECTS DUE TO FAULTY WORKMANSHIP, DESIGN OR MATERIAL FOR A
PERIOD OF 12 MONTHS FROM DATE OF SUBSTANTIAL COMPLETION,
UNLESS SPECIFIC ITEMS ARE NOTED TO CARRY A LONGER WARRANTY IN
THE CONSTRUCTION DOCUMENTS OR MANUFACTURER'S STANDARD
WARRANTY EXCEEDS 12 MONTHS. REMEDY ALL DEFECTS, OCCURRING
WITHIN THE WARRANTY PERIOD(S), AS STATED IN THE GENERAL
CONDITIONS AND DIVISION 1. ALSO WARRANT THE FOLLOWING
ADDITIONAL ITEMS:
A. ALL RACEWAYS ARE FREE FROM OBSTRUCTIONS, HOLES,
CRUSHING, OR BREAKS OF ANY NATURE
B. ALL RACEWAY SEALS ARE EFFECTIVE
C. THE ENTIRE ELECTRICAL SYSTEM IS FREE FROM ALL SHORT
CIRCUITS AND UNWANTED OPEN CIRCUITS AND GROUNDS.
THE ABOVE WARRANTIES SHALL INCLUDE LABOR AND MATERIAL MAKE
REPAIRS OR REPLACEMENTS WITHOUT ANY ADDITIONAL COSTS TO THE
OWNER.
PERFORM THE REMEDIAL WORK PROMPTLY, UPON WRITTEN NOTICE FROM
THE ENGINEER OR OWNER.
AT THE TIME OF SUBSTANTIAL COMPLETION, DELIVER TO THE OWNER
ALL WARRANTIES, IN WRITING AND PROPERLY EXECUTED, INCLUDING
TERM OMITS FOR WARRANTIES EXTENDING BEYOND THE ONE YEAR
PERIOD, EACH WARRANTY INSTRUMENT BEING ADDRESSED TO THE
OWNER AND STATING THE COMMENCEMENT DATE AND TERM.
16A 2 ELECTRICAL WORK
16A 2 -1 EXCAVATION AND BACKFILLING
EXCAVATE ALL MATERIALS ENCOUNTERED INCLUDING ROCK REQUIRED
FOR WORK UNDER THIS SECTION. BACKFILL ALL TRENCHES,
COMPACTING IN 6 —INCH LAYERS. TEST UNDERGROUND SYSTEMS,
CONFIRM WATERTIGHT INTEGRITY, AND OBTAIN ACCEPTANCE FROM
ENGINEER AND AHJ BEFORE BACKFIWNG. REMOVE FROM PREMISES
ALL EXCESS MATERIAL NOT USED IN BACKFIWNG. REPAIR ALL
STREETS, SIDEWALKS, DRIVES, PAVING AND OTHER FACILITIES DAMAGED.
REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION.
ALL BACKFIWNG AND REPAIRING SHALL MEET ALL REQUIREMENTS OF
THE OWNER, CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK
SHALL BE THOROUGHLY FIRST CLASS. CONFORM TO ALL
REQUIREMENTS OF DIVISION 2 OF THESE SPECIFICATIONS.
16A 2 -2 CLEANING
IN ADDITION TO THE REQUIREMENTS OF DIVISION 1, REMOVE FROM THE
PREMISES DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF
THE ELECTRICAL WORK, AS REQUIRED, TO PREVENT ACCUMULATION.
COOPERATE IN MAINTAINING REASONABLY CLEAN PREMISES AT ALL
11MES. IMMEDIATELY PRIOR TO FINAL INSPECTION, MAKE A FINAL
CLEANUP OF DIRT AND REFUSE RESULTING FROM THE WORK. CLEAN
ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THIS DIVISION.
REMOVE DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER FROM ALL
SURFACES. TOUCH UP AND RESTORE ALL DAMAGED FINISHES TO THEIR
ORIGINAL CONDITION.
16A 2 -3 CUTI1NG AND PATCHING
FOLLOWING THE REQUIREMENTS IN DIVISION 1, CUT WALLS, FLOORS,
CEILINGS, AND OTHER PORTIONS OF THE FACILITY AS REQUIRED TO
PERFORM WORK UNDER THIS DIVISION. OBTAIN PERMISSION OF THE
ENGINEER, OWNER, OR BOTH, BEFORE DOING ANY CUTI1NG. CUT ALL
HOLES AS SMALL AS POSSIBLE. PATCH WALLS, FLOORS, AND OTHER
PORTIONS OF THE FACILITY AS REQUIRED BY WORK UNDER THIS
DIVISION. ALL PATCHING SHALL BE THOROUGHLY FIRST CLASS AND
SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, INCLUDING
FIRE RATINGS IF APPLICABLE.
16A 2 -4 ROUGH —IN
COORDINATE WITHOUT DELAY ALL ROUGHING —IN WITH OTHER DIVISIONS.
CONCEAL ALL RACEWAYS EXCEPT IN UNFINISHED AREAS ANS WHERE
OTHERWISE INDICATED ON THE DRAWINGS.
16A 2 -5 RACEWAYS
METAWC CONDUIT AND TUBING:
A. ELECTRICAL METAWC TUBING AND FITTINGS (EMT): ANSI C80.3,
UL 797
B. FLEXIBLE METAL CONDUIT (FMC): ZINC—COATED STEEL, UL 1
C. INTERMEDIATE METAL CONDUIT (IMC): HOT— DIPPED
GALVANIZED RIGID STEEL CONDUIT: ANSI C80.6, UL 1242
D. LIQUIDITGHT FLEXIBLE METAL CONDUIT (LFMC): FLEXIBLE STEEL
CONDUIT WITH PVC JACKET: UL 360
E. RIGID METAL CONDUIT (RMC):
1. HOT —DIP GALVANIZED RIGID STEEL CONDUIT
(GRS): ANSI C80.1 UL 6
2. RIGID ALUMINUM CONDUIT (RAC): ANSI C80.5, UL 6A
F. PLASTIC— COATED IMC, RMC, AND FITTINGS: NEMA RN 1, UL
LISTED.
G. IMC AND RMC FITTINGS: NEMA FB 1; COMPATIBLE WITH CONDUIT
TYPE AND MATERIAL, UL LISTED
NON — METAWC CONDUIT AND TUBING:
A. ELECTRICAL NONMETAWC TUBING (ENT): NEMA TC 13, UL USTED
B. UQUIDTIGHT FLEXIBLE NONMETAWC CONDUIT (LFNC): UL 1660
C. RIGID NONMETAWC CONDUIT (RNC): SCHEDULE 40 PVC: NEMA
TC 2, UL 651
D. ENT AND RNC FITTINGS: NEMA TC 3, TC 6; UL 514, COMPATIBLE
WITH CONDUIT /TUBING TYPE AND MATERIAL, UL LISTED
16A 2 -6 RACEWAY INSTALLATION
INSTALL ALL CIRCULAR RACEWAYS CONCEALED ABOVE SUSPENDED
CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE
EXCEPT WHERE OTHERWISE INDICATED. PROVIDE GRS FOR ALL
CONDUITS RUN UNDERGROUND, EXPOSED TO WEATHER, OR EXPOSED TO
OTHER HAZARDOUS CONDITIONS. PROVIDE GRS INSTALLED BELOW
GRADE WITH A CORROSION RESISTANT BONDED— PLAS11C OR APPROVED
MASTIC COATING. THIS SHALL INCLUDE THE 90— DEGREE ELBOW BELOW
GRADE AND THE ENURE VERTICAL TRANSITION TO ABOVE GRADE. ALL
OTHER RACEWAY MAY BE EMT WHERE APPROVED BY LOCAL CODE.
USE COMPRESSION TYPE FITTINGS FOR EMT, WITH ALL FITTINGS UL
LISTED FOR THE ENVIRONMENT IN WHICH THEY ARE USED. AT
CONTRACTOR'S OPTION, PVC CONDUIT MAY BE USED UNDERGROUND
WHERE PERMIIIEU BY LOCAL CODE AND WHERE NOT SPECIFICALLY
RESTRICTED BY THESE DOCUMENTS.
USE FMC FOR FINAL CONNECTION TO EACH MOTOR AND TRANSFORMER,
AND TO ANY DEVICE THAT WOULD OTHERWISE TRANSMIT MOTION,
VIBRATION, OR NOISE. WHERE EXPOSED TO LIQUIDS, VAPORS OR
SUNLIGHT, USE LFMC. PROVIDE ALL FMC AND LFMC WITH AN
INSULATED GROUND WIRE
USE ONLY METAL RACEWAYS FOR ALL POWER WIRING FROM THE
OUTPUT OF VARIABLE FREQUENCY DRIVES TO THEIR RESPECTIVE
MOTORS.
INSTALL RACEWAYS PARALLEL TO BUILDING LINES.
INSTALL RACEWAYS TO REQUIREMENTS OF STRUCTURE AND TO
REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. INSTALL
RACEWAY TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS,
REINFORCING STEEL, AND OTHER IMMOVABLE OBSTACLES. INSTALL
RACEWAYS SET IN FORMS FOR CONCRETE STRUCTURE IN SUCH A
MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF
STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ENGINEER,
INSTALL NO RACEWAY IN A SLAB —ON— GRADE. LOCATE RACEWAY
BELOW GRANULAR FILL BELOW SLABS —ON —GRADE
INSTALL RACEWAYS CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS,
BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS
AND NOT MORE THAN THE EQUIVALENT OF FOUR 90— DEGREE BENDS
BETWEEN CONNECTIONS. USE MANUFACTURED ELBOWS FOR ALL 45—
AND 90— DEGREE BENDS, UNLESS APPROVED BY THE ENGINEER IN
ADVANCE. MAKE OTHER BENDS SMOOTH AND EVEN AND WITHOUT
FLATTENING RACEWAY OR FLAKING GALVANIZING OR ENAMEL RADII OF
BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN
THE CORRESPONDING TRADE ELBOW. USE LONG RADIUS ELBOWS
WHERE NECESSARY, INDICATED, OR BOTH.
SECURELY FASTEN RACEWAYS IN PLACE WITH APPROVED STRAPS,
HANGERS AND STEEL SUPPORTS AS REQUIRED. ATTACH RACEWAY
SUPPORTS TO THE BUILDING STRUCTURE. HANG SINGLE RACEWAYS FOR
FEEDERS WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND
TURNBUCKLE SUSPENSION FROM INSERTS SPACED NOT OVER 10 FEET
APART IN CONSTRUCTION ABOVE. CLAMP GROUPS OF HORIZONTAL
FEEDER RACEWAYS TO STEEL CHANNELS THAT ARE SUSPENDED FROM
INSERTS SPACED NOT OVER 10 Fkkl APART IN CONSTRUCTION ABOVE.
SECURELY CLAMP VERTICAL FEEDER RACEWAYS TO STRUCTURAL STEEL
MEMBERS ATTACHED TO STRUCTURE. INSTALL CABLE CLAMPS FOR
SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. ADD RACEWAY
SUPPORTS WITHIN 12 INCHES OF ALL BENDS, ON BOTH SIDES OF THE
BENDS. DO NOT SUPPORT RACEWAYS FROM SUSPENDED CEILING
COMPONENTS.
REAM RACEWAY ENDS, THOROUGHLY CLEAN RACEWAYS BEFORE
INSTALLATION, AND KEEP CLEAN AFTER INSTALLATION. PLUG OR
COVER OPENINGS AND BOXES AS REQUIRED TO KEEP RACEWAYS CLEAN
DURING CONSTRUCTION AND FISH ALL RACEWAYS CLEAR OF
OBSTRUCTIONS BEFORE PUWNG CONDUCTORS WIRES. PROVIDE
RACEWAYS OF AMPLE SIZE FOR PUWNG OF WIRE AND NOT SMALLER
THAN CODE REQUIREMENTS AND NOT LESS THAN 34 —INCH IN SIZE,
UNLESS INDICATED OTHERWISE ON DRAWINGS.
PROTECT ALL RACEWAY INSTALLATIONS AGAINST DAMAGE DURING
CONSTRUCTION. REPAIR ALL RACEWAYS DAMAGED OR MOVED OUT OF
LINE AFTER ROUGHING —IN TO MEET ENGINEER'S APPROVAL WITHOUT
ADDITIONAL COST TO THE OWNER.
AUGN AND INSTALL TRUE AND PLUMB ALL RACEWAY TERMINATIONS AT
PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND
JUNCTION BOXES.
INSTALL APPROVED EXPANSION /DEFLECTION FITTINGS WHERE RACEWAYS
PASS THROUGH OR ACROSS EXPANSION JOINTS.
INSTALL A PULL WIRE IN EACH EMPTY RACEWAY THAT I5 LEFT FOR
INSTALLATION OF CONDUCTORS OR CABLES UNDER OTHER DIVISIONS OR
CONTRACTS. USE POLYPROPYLENE OR MONOFILAMENT PLASTIC UNE
WITH NOT LESS THAN 200 —LB TENSILE STRENGTH. LEAVE AT
LEAST 12 INCHES OF SLACK AT EACH END OF PULL WIRE.
MAKE ALL JOINTS AND CONNECTIONS IN A MANNER THAT WILL ENSURE
MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY.
INSTALL CONDUIT — SEALING FITTINGS IN ALL RACEWAYS PASSING FROM
NON— HEATED TO HEATED SPACES.
16A 2 -7 BUSHINGS AND LOCKNUTS
RIGIDLY CLAMP CONDUITS ENTERING SHEET METAL BOXES TO THE BOX
WITH A BUSHING AND LOCKNUT ON THE INSIDE AND A LOCKNUT ON
THE OUTSIDE. CONDUIT SHALL ENTER THE BOX SQUARELY. PROVIDE
BUSHINGS AND LOCKNUTS MADE OF GALVANIZED MALLEABLE IRON WITH
SHARP, CLEAN —CUT THREADS. WHERE EMT ENTERS A BOX, PROVIDE
APPROVED EMT COMPRESSION CONNECTORS. USE INSULATED AND /OR
GROUNDING BUSHINGS WHEREVER CONNECTION IS SUBJECT TO
VIBRATION OR MOISTURE, WHEN REQUIRED BY NFPA 70, OR BOTH.
16A 2 -8 SUPPORT SYSTEMS
STEEL SLOTTED SUPPORT SYSTEMS (SLOTTED CHANNEL): COMPLY WITH
MFMA -3, FACTORY — FABRICATED COMPONENTS FOR FIELD ASSEMBLY;
12— GAUGE, 1 -5/8 —INCH BY 1 -5/8 —INCH; COPPER B —LINE, ERICO
INTERNATIONAL CORPORATION, POWER— STRUT, THOMAS & BETTS
CORPORATION, UNISTRUT.
FINISHES:
METAWC COATINGS: HOT —DIP GALVANIZED AFTER FABRICATION AND
APPLIED ACCORDING TO MFMA -3
NONMETAWC COATINGS: MANUFACTURER'S STANDARD PVC,
POLYURETHANE, OR POLYESTER COATING APPLIED ACCORDING TO
MFMA -3.
PAINTED COATINGS: MANUFACTURER'S STANDARD PAINTED COATING
APPUED ACCORDING TO MFMA -3.
STAINLESS STEEL: TYPE 304, PER ASTM A240.
ALUMINUM (EXTRUDED): TYPE 6063 —T6, PER ASTM B221
FIELD FABRICATION:
WHERE FIELD CUTTING OF STANDARD LENGTHS OF CHANNEL ARE
REQUIRED, MAKE CUTS STRAIGHT AND PERPENDICULAR TO
MANUFACTURED SURFACES.
FOR FIELD —CUT OR DAMAGED SURFACES OF COATED CHANNELS, DRESS
CUT ENDS, DAMAGED SURFACES, OR BOTH, WITH AN ABRASIVE
MATERIAL (E.G., FILE, GRINDING STONE, OR SIMILAR) AND CLEANSER TO
REMOVE OILS, RUST, SHARP EDGES AND SHARDS.
FOR CHANNEL WITH A FACTORY — APPLIED COATING, RE —FINISH CUT
EDGES WITH A COATING COMPATIBLE WITH THE FACTORY FINISH AND
AS RECOMMENDED BY THE MANUFACTURER (E.G., MANUFACTURER'S
TOUCH —UP PAINT OR ZINC —RICH COLD— GALVANIZING COMPOUND, AS
APPLICABLE).
16A 2 -9 CONDUCTORS
PROVIDE COPPER CONDUCTORS, WITH UL LABEL, AND 600V INSULATION.
SERVICE LATERAL CONDUCTORS: TYPE THWN OR XHHW WITH STRANDED
CONDUCTORS.
All FEEDER AND BRANCH CIRCUIT CONDUCTORS NO. 8 AWG AND
LARGER: STRANDED, TYPE THWN OR XHHW INSULATION.
ALL CONDUCTORS, NO. 10 AWG AND SMALLER, USED FOR POWER AND
LIGHTING CIRCUITS: SOLID COPPER, TYPE THWN (WET OR DAMP
LOCATIONS, OR IN CONDUIT BELOW GRADE OR SLAB), TYPE THHN (DRY
LOCATIONS ONLY AND ABOVE GRADE) INSULATION, OR DUAL —RATED
TYPE THHN/THWN.
ALL BRANCH CIRCUIT WIRING: NOT SMALLER THAN NO. 12 AWG. IF
NO CONDUCTOR SIZE IS INDICATED ON THE DRAWINGS FOR A BRANCH
CIRCUIT, PROVIDE NO. 12 AWG CONDUCTORS AND A 20A CIRCUIT
BREAKER.
CONDUCTORS FIELD — INSTALLED WITHIN FLUORESCENT LIGHT FIXTURE
CHANNELS: TYPE THHN.
CONTROL WIRING: STRANDED COPPER CONDUCTORS, 600V INSULATION,
OF THE PROPER TYPE, SIZE AND NUMBER AS REQUIRED TO
ACCOMPLISH SPECIFIED FUNCTION. MINIMUM SIZE: NO. 18 AWG, UNLESS
OTHERWISE NOTED.
16A 2 -10 WIRING INSTALLATION
EXCEPT WHERE SPECIFIED OR INDICATED, FOR LOW — VOLTAGE WIRING,
INSTALL ALL WIRING IN APPROVED RACEWAY AND ENCLOSURES.
SUPPORT ALL CONDUCTORS AND CABLES IN VERTICAL INSTALLATIONS,
AS REQUIRED BY NFPA 70, BY INSTAWNG CABLE SUPPORTS OR
PLUG —TYPE CONDUIT RISER SUPPORTS, OR WIRE —MESH SAFETY GRIPS.
INSTALL ALL CONDUCTORS AND CABLE IN RACEWAYS CONTINUOUS
WITHOUT TAPS OR SPLICES. SPUCE OR TAP ONLY IN APPROVED
BOXES AND ENCLOSURES WITH APPROVED SOLDERLESS CONNECTORS,
OR CRIMP CONNECTORS AND TERMINAL BLOCKS FOR CONTROL WIRING,
AND KEEP TO THE MINIMUM REQUIRED. INSULATE ALL SPLICES, TAPS,
AND JOINTS AS REQUIRED BY CODES.
ALL MATERIALS USED TO TERMINATE, SPLICE, OR TAP CONDUCTORS:
DESIGNED FOR, PROPERLY SIZED FOR, AND UL LISTED FOR THE
SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND INSTALLED IN
STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS,
USING THE MANUFACTURER'S RECOMMENDED TOOLS.
WHERE WIRING I5 INDICATED AS INSTALLED, BUT THE CONNECTION IS
INDICATED "FUTURE" OR "BY OTHER DIVISION, TRADES, OR CONTRACTS",
LEAVE A MINIMUM 3 —FOOT "PIGTAIL" AT THE BOX, TAPE NE ENDS OF
THE CONDUCTORS, AND COVER THE BOX.
THE NUMBER OF CONDUCTORS IN A SPECIFIC RACEWAY "HOME RUN" IS
INDICATED WITH CROSS LINES (TICK MARKS) ON EACH "CIRCUIT RUN"
ON THE DRAWINGS. IN GENERAL THE DIRECTION OF BRANCH CIRCUIT
"HOME RUN" ROUTING I5 INDICATED ON THE DRAWINGS COMPLETE WITH
CIRCUIT NUMBERS AND PANELBOARD DESIGNATION. CONTINUE ALL
SUCH "HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS
THOUGH "CIRCUIT
RUNS" WHERE INDICATED IN THEIR ENTIRETY.
WHEN MULTIPLE HOME RUNS ARE COMBINED INTO A SINGLE RACEWAY
SUCH THAT THE NUMBER OF CONDUCTORS EXCEEDS FOUR (CONDUCTOR
COUNT IS MADE UP OF ANY COMBINATION OF PHASE AND NEUTRAL
CONDUCTORS), THE FOLLOWING RESTRICTIONS APPLY, WHICH ARE IN
ADDITION TO THOSE IN NFPA 70:
NORMAL OR NONESSENTIAL CIRCUITS
MAXIMUM OF 16 CONDUCTORS IN A SINGLE RACEWAY. FOR UP TO
EIGHT CONDUCTORS IN A RACEWAY, MINIMUM RACEWAY SIZE: 3/4
—INCH. FOR GREATER THAN EIGHT CONDUCTORS, MINIMUM RACEWAY
SIZE: 1 —INCH. DO NOT INSTALL ANY OTHER TYPE OF CIRCUIT IN THIS
RACEWAY.
THE MINIMUM WIRE SIZE FOR ALL CONDUCTORS IN THIS RACEWAY:
N0.10 AWG. ONLY 15A AND 20A BRANCH CIRCUIT HOMERUNS MAY BE
COMBINED INTO ONE RACEWAY.
GFCI CIRCUITS
DO NOT USE MULTI — CONDUCTOR CIRCUITS, WITH A SHARED NEUTRAL,
FOR ANY GFCI CIRCUIT BREAKER OR RECEPTACLE CIRCUIT.
FOR BRANCH CIRCUITS FED FROM GFCI CIRCUIT BREAKERS, LIMIT THE
ONE —WAY CONDUCTOR LENGTH TO 100 FEEI BETWEEN THE
PANELBOARD AND THE MOST REMOTE RECEPTACLE OR LOAD ON THE
GFCI CIRCUIT.
WIRING SHALL HAVE INSULATION OF THE PROPER COLOR TO MATCH
COLOR CODE SYSTEM IN THE TABLE BELOW. IN LARGER SIZES, WHERE
PROPERLY COLORED INSULATION IS NOT AVAILABLE, USE VINYL PLASTIC
ELECTRICAL TAPE OF THE APPROPRIATE COLOR AROUND EACH
CONDUCTOR AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES.
System Voltage
208Y/120
480Y/277
Conductor Type
Phase A
Phase B
Phase C
Neutral
Equipment Ground
Isolated Ground
Phase A
Phase B
Phase C
Neutral
Equipment Ground
Isolated Ground
Color
Black
Red
Blue
White
Green
Green
w /yellow stripe
Brown
Orange
Yellow
Grey
Green
Green
w /yellow stripe
PROPERLY NUMBER ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR
CONTROL WIRING FOR IDENTIFICATION WITH VINYL STICK —ON MARKERS
OR EQUIVALENT. PROVIDE AN EQUIPMENT—GROUNDING CONDUCTOR, OR
BONDING JUMPER, AS APPLICABLE, IN ALL BRANCH CIRCUITS AND
FEEDERS, SIZED IN ACCORDANCE WITH NFPA 70 TABLES 250.66 OR
250.12.2, AS APPLICABLE, UNLESS INDICATED AS LARGER ON THE
DRAWINGS.
VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 2 PERCENT.
16A 2 -11 JUNCTION BOXES. PULL BOXES, CABINETS AND WIREWAYS
PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS
WHEREVER NECESSARY FOR PROPER INSTALLATION OF VARIOUS
ELECTRICAL SYSTEMS ACCORDING TO NFPA 70 AND WHERE INDICATED
ON THE DRAWINGS. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION
OR AS REQUIRED BY NFPA 70, WHICHEVER IS LARGER. CONSTRUCTION
SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT
INSTALLED.
JUNCTION BOXES INSTALLED BEHIND WALL CASES, AND IN OR ON
OTHER STORE FIXTURES, EXCEPT WHERE OTHERWISE SPECIFIED, SHALL
BE 4 —INCH SQUARE OR LARGER, WITH GALVANIZED COVERS.
16A 2 -12 OUTLET BOXES
ALL OUTLETS INCLUDING LIGHT FIXTURE, SWITCH, RECEPTACLE, AND
SIMILAR OUTLETS: NATIONAL ELECTRICAL APPLETON, STEEL CITY, RACO,
OR APPROVED EQUAL GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE
IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY
OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR AS
REQUIRED BY NFPA 70, WHICHEVER I5 LARGER. SET ALL OUTLET
BOXES IN WALLS, COLUMNS, FLOORS, OR CEUNGS SO THEY ARE FLUSH
WITH THE FINISHED SURFACE, ACCURATELY SET, AND RIGIDLY SECURED
IN POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND /OR
MASONRY RINGS AS REQUIRED FOR FLUSH MOUNTING. PROVIDE
APPROVED CAST OUTLET BOXES, WITH HUBS AND WEATHERPROOF
COVERS, IN ALL AREAS SUBJECT TO DAMP, WET, OR HARSH
CONDITIONS.
16A 2 -13 OUTLET LOCATIONS
COORDINATE LOCATIONS OF OUTLET BOXES, OUTLETS ARE ONLY
APPROXIMATELY LOCATED ON THE SMALL SCALE DRAWINGS. USE
GREAT CARE IN THE ACTUAL LOCATION BY CONSULTING THE VARIOUS
LARGE SCALE DETAILED DRAWINGS USED BY OTHER DIVISION TRADES,
AND BY SECURING DEFINITE LOCATIONS FROM THE ARCHITECT.
16A 2 -14 MOUNTING HEIGHTS
UNLESS NOTED OTHERWISE, INSTALL WIRING DEVICES AS INDICATED
BELOW (NOTE: ALL DIMENSIONS ARE TO THE BOTTOM OF THE OUTLET
BOX UNLESS NOTED OTHERWISE):
A. RECEPTACLES:
1. GENERAL
A. VERTICALLY WITH THE GROUND SLOT MOUNTED
AT THE TOP: 16 INCHES ABOVE FINISHED FLOOR
B. HORIZONTALLY, WITH NEUTRAL SLOT MOUNTED AT
THE BOTTOM: 16 INCHES ABOVE FINISHED FLOOR.
2. ABOVE COUNTERS:
A. FOR 36 —INCH HIGH COUNTER TOPS: 44
INCHES ABOVE FINISHED FLOOR, VERTICALLY.
B. FOR 34 —INCH HIGH COUNTER TOPS: 40 INCHES
ABOVE FINISHED FLOOR, VERTICALLY
B.
C.
3. MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS AND
JANITORS CLOSETS: 44 INCHES ABOVE FINISHED FLOOR,
VERTICALLY.
4. WEATHERPROOF EXTERIOR RECEPTACLES: 24 INCHES
ABOVE FINISHED GRADE OR AS INDICATED ON DRAWINGS,
VERTICALLY.
5. GFCI RECEPTACLES: SAME AS GENERAL RECEPTACLES.
6. ISOLATED GROUND RECEPTACLES: SAME AS GENERAL
RECEPTACLES.
7. TVSS RECEPTACLES: SAME AS GENERAL RECEPTACLES.
8. CONCRETE BLOCK WALLS: DIMENSIONS ABOVE MAY BE
ADJUSTED SLIGHTLY, AS REQUIRED TO COMPENSATE FOR
VAIABLE JOINT DIMENSIONS, SUCH THAT BOTTOM OR TOP
OF BOXES, AS APPLICABLE, ARE AT BLOCK JOINTS.
SWITCHES:
1. GENERAL: 44 INCHES ABOVE FINISHED FLOOR.
2. ABOVE COUNTERS: SAME AS FOR RECEPTACLES.
3. CONCRETE BLOCK WALLS: 40 INCHES ABOVE FINISHED
FLOOR (DIMENSIONS MAY BE ADJUSTED SLIGHTLY, AS
REQUIRED TO COMPENSATE FOR VARIABLE JOINT
DIMENSIONS, SUCH THAT BOTTOM OF BOXES ARE AT
BLOCK JOINTS).
TELEPHONE /DATA OUTLET BOXES:
1. GENERAL MATCH MOUNTING HEIGHT OF ADJACENT WIRING
DEVICE LISTED ABOVE.
2. WALL— MOUNTED TELEPHONE: 40 INCHES ABOVE FINISHED
FLOOR.
16A 2 -15 WIRING DEVICES
PROVIDE THE FOLLOWING WIRING DEVICES WHERE SHOWN ON DRAWINGS
OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF
ELECTRICAL EQUIPMENT MAY BE MADE TO COMPLY WITH STRUCTURAL
AND BUILDING REQUIREMENTS AS DETERMINED IN THE COURSE OF
CONSTRUCTION. PROVIDE ALL WIRING DEVICES OF THE SAME
MANUFACTURER AND NOT MIXED ON THE PROJECT, TO THE MAXIMUM
EXTENT POSSIBLE. PROVIDE THE COLOR OF TOGGLES AND
RECEPTACLES AS REQUESTED BY THE ENGINEER.
Pass & WFing
Type of Device Hubbell Seymour Leviton Devices
Simplex Receptacle FEEL 5361 5361 5361 5361
Duplex Receptacle HBL 5362 5362 5362 5362
Single Pale Switch HBL1221 PS 20 AC1 1221 -2 2221
Three —way Switch HBL1223 PS 20 AC3 1223 -2 2223
16A 2 -16 SWITCH AND OUTLET COVER PLATES
SWITCH AND OUTLET PLATES: COLORED, SMOOTH NYLON; BY THE SAME
MANUFACTURER AS THE WIRING DEVICES, WHEREVER POSSIBLE. VERIFY
DESIRED MATERIALS AND COLORS WITH ENGINEER BEFORE INSTALLATION.
SWITCH PLATES IN UNFINISHED ROOMS AND SPACES: STAMPED STEEL,
CADMIUM PLATED. INSTALL GROUPS OF SWITCHES UNDER ONE
GANGED — PLATE, USUALLY HORIZONTALLY; OR, WHERE REQUIRED BY
DETAILS, VERTICALLY. SET ALL COVER PLATES PLUMB, PARALI Fl , AND
FINISHED FLUSH WITH THE WALL
16A 2 -17 WEATHERPROOF COVER PLATES
PROVIDE GFCI RECEPTACLES FOR DESIGNATED WEATHERPROOF
RECEPTACLES, UNLESS INDICATED OTHERWISE ON THE DRAWINGS.
FOR UNATTENDED, WET LOCATIONS: IN —USE NEMA 3R, UL— LABELED
PLATES MOLDED FROM A CLEAR HIGH IMPACT ULTRAVIOLET STABILIZED
POLYCARBONATE MATERIAL FOR EASY VERIFICATION THAT CORDS ARE
PLUGGED IN AND THAT THE GFCI IS FUNCTIONING.
FOR ATTENDED WET OR DAMP LOCATIONS: WEATHERPROOF COVER
PLATES, UL—USTED FOR WET LOCATIONS WITH COVER(S)
CLOSED;
DIE —CAST ALUMINUM OR TYPE 302 STAINLESS STEEL; SINGLE —COVER
FOR SWITCHES AND VERTICALLY MOUNTED RECEPTACLES;
DOUBLE —COVER FOR HORIZONTALLY MOUNTED RECEPTACLES;
SELF—CLOSING COVERS
zumez
SOUTHW TER MALL
SPAGE # 2115
633 SourscansTER
SKiniz, WA 98188
MURPHY V REYps
DAVID I. MURPHY, AIA
moot Huse Ames Otass ii
B..ss, Maim= g8eu
T: so6.34c.9875
r: sob grn
S: .w.. MuvnYYm ooi
Harrison French and
Associates
809 S.W. "A" Street
Bentonville, AR 72712
(479) 273 -7780
fax (479) 273 -9436
EXPIRES: 07/22/08
IiEWE® FUI
COVER PLATES: BY THE SAME MANUFACTURER AS THE WIRING D VI COMPLIANCE
E C _
COMPLYING WITH NFPA 70 406.8 (A) OR (B) REQUIREMENTS FOR
NEC
ATTENDED OR UNATTENDED USE AS APPLICABLE. NFPA 70
16A 2 -18 FIRESTOPPING FLOOR AND WALL PENETRATIONS
FIRE — RESISTANT PENETRATION SEALANTS: TWO —PART,
FOAMED —IN— PLACE, SILICONE SEALANT FORMULATED FOR USE IN
THROUGH — PENETRATION FIRE — STOPPING AROUND CABLES, RACEWAYS,
AND CABLE TRAY PENETRATIONS THROUGH FIRE —RATED WALLS AND
FLOORS. SEALANTS AND ACCESSORIES SHALL HAVE FIRE — RESISTANCE
RATINGS INDICATED, AS ESTABLISHED BY TESTING IDENTICAL
ASSEMBLIES IN ACCORDANCE WITH ASTM E 814, BY UNDERWRITERS'
LABORATORIES, INC., OR OTHER NRTL ACCEPTABLE TO AHJ.
PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE
ONE OF THE FOLLOWING:
1. "3M FIRE STOP FOAM #2001, " 3M CORP.
2. "METACAULK 835 +, " RECTORSEAL
3. "SPECSEAL PENSIL 200 SIUCONE FOAM," SPECIFY
TECHNOLOGY INC.
4. "FIRE STOP SYSTEM," UNITED STATES GYPSUM
COMPANY.
16A 2 -19 EQUIPMENT IDENTIFICATION
PROVIDE EQUIPMENT IDENTIFICATION NAMEPLATES ON ALL
PANELBOARDS, SWITCHES, AND WHERE INDICATED ON THE DRAWINGS.
NAMEPLATES:
A. ENGRAVED, CONTRASTING COLOR, THREE — LAYER, LAMINATED
PLASTIC INDICATING THE NAME OF THE EQUIPMENT, LOAD, OR
CIRCUIT AS DESIGNATED ON THE DRAWINGS AND IN THE
SPECIFICATIONS.
B. FIELD—APPUED PERMANENT EPDXY ADHESIVE, COMPATIBLE WITH
THE EQUIPMENT FINISH, ATTACHMENT METHOD SHALL BE
ACCEPTABLE TO THE MANUFACTURERS OF THE EQUIPMENT TO
WHICH THE NAMEPLATES ARE BEING APPLIED.
C. COLOR: BLACK BACKGROUND WITH WHITE LETTERS FOR NORMAL
POWER; LEIIER HEIGHT: 1/2 —INCH MINIMUM
APR - 3 -MB
city Tikvuila
B IL N NISI
RECEIVED
CITY OF TUKWIIA
MAR 2 8 ZOU8
PERMIT CENTER
PROJECT NUMBER: 05-08 -02008
ZUMIEZ STORE NUMBER: 19
ISSUED FoR:
PRELIMINARY MALL
REVIEW
DATE:
02-08-08 PRELIMINARY MALL REVIEW
SHEET TITLE:
ELECTRI CAL
SPECS
SHEET NUMBER:
E4