HomeMy WebLinkAboutPermit EL08-0390 - SABEY CORPORATIONSABEY CORPORATION 3355 S 120 PL EXPIRED 03 -14 -09 ELO8-390 Citiif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -390 Issue Date: 09/15/2008 Permit Expires On: 03/14/2009 Tenant: Name: SABEY CORPORATION Address: 3355 S 120 PL , TUKWILA WA Owner: Name: SABEY CORPORATION Phone: Address: 12201 TUKWILA INTL BLVD 4THFL , SEATTLE WA Contact Person: Name: MACKENZIE CRAIN Phone: 206 436 -5232 Address: 5614 7 AV S , SEATTLE WA Contractor: Name: VECA ELECTRIC CO INC Phone: 206 860 -0231 Address: 5614 7 AV S , SEATTLE WA Contractor License No: VECAECI542MU Expiration Date: 10/31/2009 DESCRIPTION OF WORK: RELOCATE COMMON BUILDI LOADS TO A NEW SWITCHBOARD Value of Electrical: $6,000.00 Type of Fire Protection: Electrical Service provided by: SEATTLE CITY LIGHT Permit Center Authorized Signature: UJJL Fees Collected: National Electrical Code Edition: $225.50 2005 Date: 9 -1`_ C/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perf rmance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: L)05. L. /V e- 4.5 Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -390 Printed: 09 -15 -2008 Parcel No.: 1023049069 Address: Suite No: Tenant: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 3355 S 120 PL TUKW SABEY CORPORATION PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -390 ISSUED 04/10/2008 09/15/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a perrnit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change m the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: c,( Date: < —rl ^G� doc: Cond -Elec EL08 -390 Printed: 09 -15 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto:/lwww.ci.tukwila.wa.us Electrical Permit No.a/Oi "56lo_ Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: 3355 S. 120th PL. Seattle, WA 98168 Suite Number: Floor: New Tenant: ❑ Yes ❑..No Property Owners Name: Sabey Corporation Mailing Address: 12201 Tukwila Int'l Blvd. -4th Floor Tukwila City WA State 98168 Zip CONTACT PERSON -Who do we.contact when your permit is ready to be issued Name: Mackenzie Crain Mailing Address: 5614 7th Ave South Day Telephone: 206 -436 -5232 Seattle WA 98108 E -Mail Address: mackenzie.crain@veca.com City Fax Number: State 206 - 763 -0505 Zip ELECTRICAL CONTRACTOR INFORMATION Company Name: VECA ELECTRIC Mailing Address: 5614 7th Ave South Contact Person: Nancy Dumont E -Mail Address: nancy.dumont@veca.com Contractor Registration Number: VECAECI542Mu Seattle WA City State Day Telephone: 206- 860 -0231 Fax Number: 206- 860 -0233 98108 Zip Expiration Date: 10/31/08 Valuation of Project (contractor's bid price): $ 6,000.00 Scope of Work (please provide detailed information): Relocate common building loads to a new switchboard. Will service be altered'? ❑ Yes ❑ No Adding more than 50 amps? © Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ❑ Puget Sound Energy Seattle City Light H: Applications\Fonns- Applications On Lineal -2007 - Electrical Permit Application.doc bh Page 1 oft RESIDENTAAi, NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) LI Service change with added/altered circuits $75.00 number of added circuits -- - $10:00 ca ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65 -00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) - $58.00 ❑ 'I emporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules.. Expiration of Plan Review Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWg R OR ELECTRICAL CONTRACTOR: Signatu Print Name: LAURA RANNOW Mailing Address: 5614 7TH AVE S,SEATTLE, WA 98108 Date: Day Telephone: 206- 436 -5245 Date Application Accepted: 0 01 Date Application Expires: City State Zip o ES0 U� Staff Initials: II. Applications Fours- Applications On I Inc 4 -2007 - Electrical I'cmut AppI -atinn.doc nn Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 1023049069 Address: 3355 S 120 PL TUKW Suite No: Applicant: SABEY CORPORATION RECEIPT Permit Number: EL08 -390 Status: PENDING Applied Date: 04/10/2008 Issue Date: Receipt No.: R08 -01121 Initials: JEM User ID: 1165 Payment Amount: $225.50 Payment Date: 04/10/2008 10:11 AM Balance: $0.00 Payee: VECA ELECTRIC CO INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1221 225.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 180.40 000.345.832.00.0 45.10 Total: $225.50 rinr. RPc..int -OR Printpri• na_1n_2nna 02 -02 -2009 MACKENZIE CRAIN 5614 7 AV S SEATTLE WA 98108 City of Tukwila Jim Haggerton, Mayor Department of Community Development RE: Permit No. EL08 -390 3355 S 120 PL TUKW Dear Permit Holder: Jack Pace, Director In reviewing our current records the above noted permit has not received a fmal inspection by the City of Tukwila Building Division. Per the Intemational Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or fmal inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 03/14/2009 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, —b`LLQ. Bill Rambo Permit Technician xc: Permit File No. ELO8 -390 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206- 431 -3670 o Fax: 206- 431 -3665 09 -08 -2008 MACKENZIE CRAIN 5614 7 AV S SEATTLE WA 98108 CityofTu.A°la Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit Application No. EL08 -390 3355 S 120 PL TUKW Dear Permit Applicant: In reviewing our current permit application files, it appears that your permit application applied for on 04/10/2008 , has not been issued by the City of Tukwila Permit Center. Per the International Codes, Uniform Plumbing Code and/or the National Electrical Code, every permit application not issued within 180 days from the date of application shall expire by limitation and become null and void. Your permit application expires on 10/07/2008 . If you choose to pursue your project, a written request for extension of your application addressed to the Building Official, demonstrating justifiable cause, will need to be received at the Permit Center prior to your expiration date of 10/07/2008 . If it is determined that an extension is granted, your application will be extended for an additional 90 days from the expiration date. In the event we do not receive your written request for extension, your permit application will become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, fifer Marshall ermit Technician xc: Permit File No. EL 08 -390 6300 Southcenter Boulevard, Suite #100 • Tukwila. Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 • PERMIT COORD COPY ~ PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -390 DATE: 04 -10 -08 PROJECT NAME: SABEY CORPORATION SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bui g uiviis�vion Public Works Fire Prevention Structural Planning Division nPermit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete RI Incomplete Comments: DUE DATE: 04 -15-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05-13-08 Approved Approved with Conditions V Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Untitled Page • Page 1 of 3 Electrical Contractor A business licensed by LEtI to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company VECA ELECTRIC CO INC 2064365200 5614 7TH AVE S PO BOX 80467 SEATTLE WA 98108 KING CORPORATION UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Previous License Next License Associated License Specialty 1 Specialty 2 601190731 ACTIVE VECAECI542MU ELECTRICAL CONTRACTOR 7/31/1946 10/31/2009 CONTIK`965D6 GENERAL UNUSED MASTER ELECTRICIAN INFORMATION License CONTIK*965D6 Name CONTI, KEITH Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date FAIRBANKS, THOMAS Cancel Date 01/01/1980 Bond Amount ALLEN, RON AGENT 01/01/1980 929407110 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 WESTERN SURETY CO 929407110 01/06/2007 Until Cancelled $4,000.00 01/06/2007 TRAVELERS https: / /fortress.wa. gov /lni/bbip/Detail. aspx ?License = VECAECI542MU 09/15/2008 LOAD DISTRIBUT1ON RCPT LTG EQP HEAT 60.0 66.7 120.0 0.0 28.6 24.0 0.0 23.7 VECA Electric ROOM HOUSE POWER DISTAREA FROM 4000AMDR DESCRIPTION SWBD AMP P kVA AMPS PANEL HFI-I1 120 KW UPS 225 3 127 150 3 120 3 53 150 3 24 84.5 77.3 167.1 ELEVATOR #1 PANEL HFL.1 VIA 75 KVA PANS HR.3 VIA 112.5 KVA AC-3 100 100 225 85 77 167 152 144 63 29 AM? VOLTS: 1200 277 480 102 93 201 PHASE WIRE BUS: A.I.C. ML.O.: ELEVATOR #2 ELEVATOR #3 MAIN CB: FUSE IG GND: 200% N. FD THRU: DBL LUG: TOP. PANEL T.C.L. LOAD (kVA) RCPT LTG EQP TOTAL FEEDER T.C.L. LOAD (kVA) RCPT - TOTAL TOTAL 713 FEEDER DEMAND kVA 735 713 858 AMPS 884 MFG: SO D CB: NOTE SDC CON/MON AREA 1/18/08 01/18/08 PANEL SCHEDULE PANEL H P H 1 SEC I LOCATION: ELECT RM VOLTS: 480 Y/ 277 P 3 AIC RATING: 14,000 FEED - THROUGH LUGS NEUTRAL: 100% W: 4 AMP: 225 MLO X MCB II MOUNT: X SURFACE FLUSH TYPE: EXISTING NEW © STYLE: FED FROM: PANEL HDHP CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR ii P CKT BKR LOAD KVA LOAD TYPE } CIRCUIT DESCRIPTION LTG - 1ST FLOOR SECURITY RM (SOURCE= PNL 2H2A -2) LTG 0.63 20 1 1 A B C A B C A B C A B C A B C A B C A 6 2 3 30 5.54 MISC SPACE HEATER - RM 400 (SOURCE= PNL 2H2D- 14,16,18) LTG - AIR INTAKE TUNNEL (SOURCE= PNL 2H2A -18) LTG 1.92 20 1 3 4 - - 5.54 MISC - SPACE HEATER - RM 159 (SOURCE= PNL 2H2B- 32,34,36) MISC 2.57 20 3 5 6 - - 5.54 MISC - - MISC 2.57 - - 7 8 3 20 3.00 MTR DEWATERING PUMP NORTH (SOURCE= PNL 2H2D- 2,4,6) - MISC 2.57 - - 9 10 - - 3.00 MTR - AIR COMP. - SPRINKLER RM 159 (SOURCE= PNL 2H2B- 38,40,42) MTR 1.83 20 3 11 12 - - 3.00 MTR - - MIR 1.83 - - 13 14 3 20 3.00 MTR SEVER LIFT STATION (SOURCE= PNL 2H2D- 8,10,12) - MTR 1.83 - - 15 16 - - 3.00 MTR - SPACE HEATER - RM 160 (SOURCE= PNL 2H2C- 32,34,36) MISC 2.57 20 3 17 18 - - 3.00 MTR - - MISC 2.57 - - 19 20 1 20 1.55 LTG LTG - RM 101, 107, 108, 109 (SOURCE= PNL 21-12D -2 -1) - MISC 2.57 - - 21 22 1 20 3.00 LTG LTG - RM 104, 105, 106 (SOURCE= PNL 2H2D -2 -2) AIR COMP. - SPRINKLER RM 160 (SOURCE= PNL 2H2C- 38,40,42) MTR 1.83 20 3 23 24 1 20 1.40 LTG LTG - LOBBY 100, HALLWAY 102 (SOURCE= PNL 2H2D -2 -3) - MTR 1.83 - - 25 26 1 20 3.20 LTG LTG - SHIPPING /RECEIVING (SOURCE= PNL 2H2D -2 -4) - MTR 1.83 - - 27 28 1 20 1.30 LTG LTG,- RM 120, 121, 122 (SOURCE= PNL 2H2D -2 -5) LTG - SPRINKLER VAVLE RM 159 (SOURCE= PNL 2H2D -9) LTG 1.44 20 1 29 30 1 20 3.26 LTG LTG'- SHIPPING & RECEIVING (SOURCE= PNL 2H2D -2 -6) LTG - SPRINKLER VAVLE RM 160 (SOURCE= PNL 2H2D -11) LTG 1.92 20 1 31 32 1 20 3.00 LTD LTG - ,RM 121A, 1218, 121C (SOURCE= PNL 2H2D -2 -7) LTG - PENTHOUSE RM 400 (SOURCE= PNL 2H2D -13) LTG 0.90 20 1 33 34 1 20 1.61 LTG LTG, ;#' RM 146, 137, 138, 139 (SOURCE= PNL 2H2D -2 -8) SPARE 1.54 0.50 20 1 35 36 1 20 2.30 LTG LTC'- RM 145, 136 (SOURCE= PNL 2H2D -2 -12) SPARE REC 1.08 20 1 37 38 1 20 1.99 LTG L.TG - 'EXTERIOR (SOURCE= PNL- 2H2D- 2 -14). SPARE MTR 0.50 20 1 39 40 1 20 3.00 LTG iG - ;EXTERIOR (SOURCE= PNL- 2H2D -2 -16) SPARE 20 1 20 1 41 C 42 1 20 3.50 - SPARE B ' 20 1 20 1 3.5 12.6 75 76 200% N: ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 31 r ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 35 LTG EGRESS STAR 2, HALLWAY 146 C LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED 1 CONNECTED PHASE LOADING LIGHTING LTG 50.54 KVA RESIDENT LTG /RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 9.00 KVA REMAINING MOTORS MTR 19.98 KVA GEN PURPOSE RECPT REC 0.00 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 14.64 KVA HEATING MISC 32.04 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 126.20 KVA 151.80 AMPS LOAD TYPE NOTES: 63.18 KVA (125 %) 0.00 KVA ( 100/35/25 0.00 KVA ( 100/35/25 %) 11.25 KVA (125 %) 19.98 KVA (100 %) 0.00 KVA ( 50% > 10KVA) 0.00 KVA (100 %) 14.64 KVA (100 %) 32.04 KVA (100%) 0.00 KVA 0 100% - 0.00 KVA 0 65% 141.09 KVA 169.70 AMPS AT INDICATED DEMAND AT 100% PHASE A: 45.20 KVA PHASE B: 42.93 KVA PHASE C: 38.07 KVA 1 1 GENERAL NOTES: NO FLAG NOTES: 1.20 'COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG /RECPT OR SMALL APPLIANCE LOAD TAKEN 'MISC' = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT PANEL SCHEDULE VECA Electric PANEL: HPH1 -2 FEED -THRU: ROOM. HOUSE POWER DIST AREA LOADS FROM HDHP -1 CIRCUIT DESCRIPTION A B C P RCPT LTG EOP HEAT CKT DESCRIPTION FH AMP P KVA Atr1PS KVA AMPS KVA AMPS 2 1 20 3.49 KITCH COFFEE MAKER - RM 136 (SOURCE= PNL 2L2A- 38 -10) 1 LTG OFFICE Rtvt 114 A 20 1 3.5 12.6 1 20 1.08 REC REC - RM 104, 106 (SOURCE= PNL 2L2A- 36 -11) SPARE PENTHOUSE (SOURCE= PNL 2L2A -6) 5.88 1.00 20 3 LTG RMS117, 116, 115, 121A, 105A B 20 1 20 1.00 5.9 21.2 AIR INTAKE (SOURCE= PNL 2L2A -7) REC AMP: 225 1 2.47 8 1 5 LTG OFFICE RM1114 C 20 1 AIR INTAKE (SOURCE= PNL 2L2A -13) REC 0.72 20 2.5 8.9 VOLTS: 277 -- 20 2.40 KITCH 7 MECH DOCK LEVELER A A 20 3 2.4 8.7 ----_ 12 1 480 0.72 REC 2.40 SECURITY / LOBBY (SOURCE= PNL 2L2A -16) 9 " B 20 1 13 14 2.4 8.7 20 PH: 3 SPARE TO J -BOX CORRIDOR 146 (SOURCE= PNL 2L2A- 3B -16) REC - RM 110, 120, 121, 122, 114 (SOURCE= PNL 2L2A -3A -2) 2.40 1.08 11 C " „ 1 20 0.90 2.4 8.7 \MRE 4 REC 0.90 2A0 1 13 MECH DOCK LEVELER B A 20 3 2.4 8.7 REC - RM 115, 116, 117 (SOURCE= PNL 2L2A- 3B -19) REC - SHIPPING & RECEIVING (SOURCE= PNL 2L2A- 3A -14) BUS: AL 20 1 2.40 20 15 B 1.08 REC REC - RM 115, 116, 117 (SOURCE= PNL 2L2A- 38 -21) REC - SHIPPING & RECEIVING (SOURCE= PNL 2L2A- 3A -16) 2.4 8.7 0.90 A.LC.: CU 21 22 2.40 20 17 C SPARE TO RM 121 A (SOURCE= PNL 2L2A- 38 -24) REC - RM 100, 102, 103, 114 (SOURCE= PNL 2L2A- 3A -21) REC 0.72 20 1 2.4 8.7 MLO: YES 1.08 0.50 REC - RM 114 (SOURCE= PNL 2L2A- 3B -27) REC - RM 100, 102 (SOURCE= PNL 2L2A- 3A -37) 19 LTG 1ST FLOOR PHASE 3 & 4 A 20 1 0.5 1.8 1 20 1.08 REC MAIN CB: REFRIG. - RM 136 (SOURCE= PNL 2L2A -3B -2) 0.61 1.00 20 21 LTG AIR TUNNEL B 20 1 20 0.72 0.6 2.2 REC - RM 146 (SOURCE= PNL 2L2A -3B -3) REC 3R: 20 1 0.36 30 1 23 LTG SECURITY ROOM C 20 1 VENDING MACHINE - RM 136 (SOURCE= PNL 2L2A -3B -4) MISC 0.50 20 0.4 1.3 FLUSH: 1 20 0.42 MISC PRITNER - RM 114 (SOURCE= PNL 2L2A- 3B -33) 25 LTG SPRINKLER RM1159 STAIR 5 A 20 1 0.4 1.5 34 1 20 WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -34) SURF: YES VENDING MACHINE - RM 136 (SOURCE= PNL 2L2A -36 -6) 1.54 0.50 20 27 LTG EGRESS SHIPIREC, Rtv1 122 6 20 1 20 WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -36) 1.5 5.6 REC - RM 125, 138, 139, 146 (SOURCE= PNL 2L2A -3B -7) REC 1.08 20 1 0.42 38 3 29 LTG SPRINKLER RM 160 STAR 4 C 20 1 GARBAGE DISPOSAL - RM 136 (SOURCE= PNL 2L2A -3B -8) MTR 0.50 20 0.4 1.5 40 - - 2:08 COMB 31 LTG EXTERIOR LIGHTS A 20 1 2.1 7.5 41 42 - IG GRND 4.04 3.50 - 33 LTG EXTERIOR LIGHTS B ' 20 1 20 1 3.5 12.6 75 76 200% N: ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 31 1.20 LOAD SUMMARY: LOAD TYPE CONNECTED EM.D. CALCULATED 35 LTG EGRESS STAR 2, HALLWAY 146 C 20 1 UGHIING LTG 0.00 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 1.00 KVA REMAINING MOTORS MTR 0.50 KVA GEN PURPOSE RECPT REC 66.92 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 6.50 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 4.00 KVA TOTALS 78.92 KVA 219.06 AMPS WAD TYPE NOTES: 0.00 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 1.25 KVA (125 %) 0.50 KVA (100 %) 38.46 KVA ( 50% > IOKVA) 0.00 KVA (100%) 6.50 KVA (100 %) 0.00 KVA (100%) 0.00 KVA 0 100% 2.60 KVA co 65% 49.31 KVA 136.87 AMPS AT INDICATED DEMAND AT 100% PHASE A: 27.80 KVA PHASE B: 25.88 KVA PHASE C: 25.24 KVA 1:2 4.3 FDTHRU NO 1.00 1.20 'COMB' = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES' = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN "MISC' = EQUIP. COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT 37 LTG EGRESS RM 100, 102, 114 A . 20 1 1.2 4.3 20 1 DBL LUG ■■■■ 39 B 20 1 MECH EWt1 -3 JANTOR STORAGE 0.0 -0A 20 TOR YES 1 81 4 1 82 C .20 1 SPACE 0.0 0.0 BTM: SPARE A " 20 1 12.5 83 C 84 DBL LUG. 0.18 2 A 20 2 0.0 0.0 20 1 PANEL T.C.L. 0.2 1.5 4 B C 20 2 - --- 0.0 0.0 ■ 0.0 LOAD 0.0 RCPT (kVA) 0.0 ---- C 20 6 _ _ _ _ LOAD SUMMARY: LOAD TYPE CONNECTED E.M.D. CALCULATED r? A 0.0 LIGHTING LTG 0.00 KVA RESIDENT LTG / RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 1.00 KVA REMAINING MOTORS MIR 0.00 KVA GEN PURPOSE RECPT REC 5.30 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 3.50 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 2.00 KVA TOTALS 11.80 KVA 32.75 AMPS LOAD TYPE NOTES: 0.0 0.0 PHASE A: 4.18 KVA PHASE B: 3.58 KVA PHASE C: 4.04 KVA LTG 28.6 3 40 , 10 LTG GEN 52 RIO B 20 1 3.4 12.3 2 1.50 12 LTG SVVBD RM 52 C 20 1 A 20 1.5 5.4 HEAT 0.0 3.20 , 14 4 DM GEN RM 52 H FANS A 20 3 3.2 11.6 4 NECHFASRNKLBR VALVE RM159 B 20 1 3.20 0.5 4.2 3.2 11.6 (kVA) TOTAL 52.6 0.50 3.20 18 C 20 " 3.2 11.6 n - --- 3.7 20 `� A 20 1 0.0 0.0 GEN 52A BATT CHARGER Ilk\ A FEEDER T.C.L. i• ---- 0.8 6.7 22 6 C "20 29. 1 1 -- 0.0 0.0-- 0.0 LOAD 0.0 RCPT (kVA) 0.0 GEN 52B BATT CHARGER 24 20 1 26 A 20 " 1 0.0 0.0 EQP 24.0 LTG 28.6 0.40 12 28 B 20 1 0.0 0.0 EOP 24.0 3.3 HEAT 6.0 30 C 20 1 GEN 52B DAY TANK A 0.0 OA HEAT 0.0 3.3 32 A 20 1 0.0 0.0 7 16 " •' ' B 20 1 34 B 20 1 ' 0.0 0.0 33.7 I TOTAL 52.6 :i~.�: 36 C C 20 1 0.0 0.0 LG MTR 9.0 0.18 38 A 20 1 0.0 0.0 20 1 FEEDER MN! AhD 1.5 40 B 20 1 0.0 0.0 s :D -.r • kVA 59.7 1 42 1.5 C 20 1 (kVA) 0.0 0.0 AMPS 71.8 GEN 52A BLOCK HEATER C 20 2 A 0.0 0.0 RCPT 3.7 1.50 26 " B " 1.5 0.0 0.0 �' LTG - C " " 28 GEN 52B BLOCK I -EATER 0.0 0.0 0.0 : 24.0 0.0 1.5 MFGICB: Remarks: - SECTION 2. SEC COMMow LOAD- 1/18/08 KVA /AMPS: 15.7 56.6 22.9 82.8 14.0 50.4 01/18/08 1.50 30 C 0A 7,7 8.0 0.0 A 0.0 14.9 8.0 0.0 B 0.0 6.0 8.0 0.0 C PANEL SCHEDULE PANEL HPL1 SEC I LOCATION: ELECT RM VOLTS: 208 Y/ 120 P 3 AIC RATING: 14,000 FEED - THROUGH LUGS NEUTRAL: 100% W: 4 AMP: 225 MLO X MCB • MOUNT: © SURFACE • FLUSH TYPE: EXISTING J NEW © STYLE: FED FROM: PANEL HDHP VIA 75kVA XFMR CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR # P H CIR / P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION PENTHOUSE ROOF RECEPT (SOURCE= PNL 2L2A -2) REC 0.50 20 1 1 < CO 0< CO 0< m 0< m 0< m 0< m 0< 010 2 1 20 0.50 KITCH COFFEE MAKER - RM 136 (SOURCE= PNL 2L2A- 38 -10) SPARE PENTHOUSE (SOURCE= PNL 2L2A -4) REC 1.00 20 1 3 4 1 20 1.08 REC REC - RM 104, 106 (SOURCE= PNL 2L2A- 36 -11) SPARE PENTHOUSE (SOURCE= PNL 2L2A -6) REC 1.00 20 1 5 6 1 20 1.00 KITCH MICROWAVE - RM 136 (SOURCE= PNL 2L2A- 3B -12) AIR INTAKE (SOURCE= PNL 2L2A -7) REC 0.90 20 1 7 8 1 20 1.08 REC REC - RM 104, 105, 106 (SOURCE= PNL 2L2A- 3B -13) AIR INTAKE (SOURCE= PNL 2L2A -13) REC 0.72 20 1 9 10 1 20 0.50 KITCH TOASTER - RM 136 (SOURCE= PNL 2L2A- 3B -14) PENTHOUSE (SOURCE= PNL 2L2A -14) REC 0.50 20 1 11 12 1 20 0.72 REC REC - RM 111, 112 (SOURCE= PNL 2L2A- 3B -15) SECURITY / LOBBY (SOURCE= PNL 2L2A -16) REC 0.50 20 1 13 14 1 20 1.00 REC SPARE TO J -BOX CORRIDOR 146 (SOURCE= PNL 2L2A- 3B -16) REC - RM 110, 120, 121, 122, 114 (SOURCE= PNL 2L2A -3A -2) REC 1.08 20 1 15 16 1 20 0.90 REC REC - RM 105, 111, 112 (SOURCE= PNL 2L2A- 3B -17) REC - SHIPPING & RECEIVING (SOURCE= PNL 2L2A- 3A -12) REC 0.90 20 1 17 18 1 20 1.08 REC REC - RM 115, 116, 117 (SOURCE= PNL 2L2A- 3B -19) REC - SHIPPING & RECEIVING (SOURCE= PNL 2L2A- 3A -14) REC 0.90 20 1 19 20 1 20 1.08 REC REC - RM 115, 116, 117 (SOURCE= PNL 2L2A- 38 -21) REC - SHIPPING & RECEIVING (SOURCE= PNL 2L2A- 3A -16) REC 0.90 20 1 21 22 1 20 1.00 REC REC SPARE TO RM 121 A (SOURCE= PNL 2L2A- 38 -24) REC - RM 100, 102, 103, 114 (SOURCE= PNL 2L2A- 3A -21) REC 0.72 20 1 23 24 1 20 1.08 REC REC - RM 114 (SOURCE= PNL 2L2A- 3B -27) REC - RM 100, 102 (SOURCE= PNL 2L2A- 3A -37) REC 0.50 20 1 25 26 1 20 1.08 REC REC - ADMIN ROOM (SOURCE= PNL 2L2A- 3B -29) REFRIG. - RM 136 (SOURCE= PNL 2L2A -3B -2) MISC 1.00 20 1 27 28 1 20 0.72 REC REC - ADMIN ROOM (SOURCE= PNL 2L2A- 3B -31) REC - RM 146 (SOURCE= PNL 2L2A -3B -3) REC 0.72 20 1 29 30 1 20 1.08 REC REC - RM 125 (SOURCE= PNL 2L2A- 3B -32) VENDING MACHINE - RM 136 (SOURCE= PNL 2L2A -3B -4) MISC 0.50 20 1 31 32 1 20 1.00 MISC PRITNER - RM 114 (SOURCE= PNL 2L2A- 3B -33) REC - RM 146 (SOURCE= PNL 2L2A -3B -5) REC 0.90 20 1 33 34 1 20 WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -34) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -35) SPARE IN RM 126 (SOURCE= PNL 2L2A- 36 -37) VENDING MACHINE - RM 136 (SOURCE= PNL 2L2A -36 -6) MISC 0.50 20 1 35 36 1 20 WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -36) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -37) SPARE REC - RM 125, 138, 139, 146 (SOURCE= PNL 2L2A -3B -7) REC 1.08 20 1 37 38 3 100 4.18 COMB PANEL HPL2 GARBAGE DISPOSAL - RM 136 (SOURCE= PNL 2L2A -3B -8) MTR 0.50 20 1 39 40 - - 3.58 COMB - REC - RM 127 (SOURCE= PNL 2L2A -36 -9) REC 0.90 20 1 41 42 - - 4.04 COMB - REC - RM 121A (SOURCE = PNL 212E -28) REC 1.00 20 1 75 76 1.00 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 31 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE CONNECTED EM.D. CALCULATED 20 LOAD SUMMARY: LOAD TYPE CONNECTED E.M.D. CALCULATED LIGHTING LTG 0.00 KVA RESIDENT LTG / RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 0.00 KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 40.00 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 0,00 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 40.00 KVA 111.03 AMPS ,LOAD TYPE NOTES: CONNECTED PHASE LOADING UGHIING LTG 0.00 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 1.00 KVA REMAINING MOTORS MTR 0.50 KVA GEN PURPOSE RECPT REC 66.92 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 6.50 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 4.00 KVA TOTALS 78.92 KVA 219.06 AMPS WAD TYPE NOTES: 0.00 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 1.25 KVA (125 %) 0.50 KVA (100 %) 38.46 KVA ( 50% > IOKVA) 0.00 KVA (100%) 6.50 KVA (100 %) 0.00 KVA (100%) 0.00 KVA 0 100% 2.60 KVA co 65% 49.31 KVA 136.87 AMPS AT INDICATED DEMAND AT 100% PHASE A: 27.80 KVA PHASE B: 25.88 KVA PHASE C: 25.24 KVA 1 1 GENERAL NOTES: 78 FLAG NOTES: 1.00 'COMB' = COMBINATION LOAD TYPES ON INDICATED CIRCUIT 'RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN 'MISC = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT 'COMB' = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES' = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN "MISC' = EQUIP. COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT PANEL SCHEDULE PANEL HPL1 SEC 11 LOCATION: ELECT RM VOLTS: 208 Y/ 120 P 3 AIC RATING: 14,000 NEUTRAL: 100% W: 4 AMP: 225 MLO X MCB MOUNT: © SURFACE • FLUSH TYPE: EXISTING NEW Q STYLE: FED FROM: PANEL HPL1 SEC I MA FEED- THROUGH CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CR # P H OR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION WORKSTATION POWER (SOURCE= PNL 2L2C -3A -1) REC 1.00 20 1 1 c7 m > co > co > n co > c7 ao > co > co DJ 2 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C -3A -2) WORKSTATION POWER (SOURCE= PNL 2L2C -3A -3) REC 1.00 20 1 3 4 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C -3A -4) WORKSTATION POWER (SOURCE= PNL 2L2C -3A -5) REC 1.00 20 1 5 6 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C -3A -6) WORKSTATION POWER (SOURCE= PNL 2L2C -3A -7) REC 1.00 20 1 7 8 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C -3A -8) WORKSTATION POWER (SOURCE= PNL 2L2C -3A -9) REC 1.00 20 1 9 10 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -10) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -11) REC 1.00 20 1 11 12 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -12) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -13) REC 1.00 20 1 13 14 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -14) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -15) REC 1.00 20 1 15 16 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -16) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -17) REC 1.00 20 1 17 18 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -18) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -19) REC 1.00 20 1 19 20 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 212C- 3A -20) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -21) REC 1.00 20 1 21 22 1 20 1.00 REC REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -22) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -24) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -23) REC 1.00 20 1 23 24 1 20 1.00 WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -25) REC 1.00 20 1 25 26 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -26) WORKSTATION POWER (SOURCE= PNL 2L2C-3A--27) REC 1.00 20 1 27 28 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -28) WORKSTATION POWER (SOURCE = PNL 2L2C- 3A -29) REC 1.00 20 1 29 30 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -30) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -31) REC 1.00 20 1 31 32 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -32) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -33) REC 1.00 20 1 33 34 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -34) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -35) REC 1.00 20 1 35 36 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -36) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -37) REC 1.00 20 1 37 38 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -38) WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -39) REC 1.00 20 1 39 40 1 20 1.00 REC WORKSTATION POWER (SOURCE= PNL 2L2C- 3A -40) SPARE MISC 0.50 20 1 41 42 1 20 1 20 SPARE SPACE SPARE REC - RM 121A (SOURCE = PNL 212E -28) REC 1.00 20 1 75 76 1.00 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 31 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS LOAD SUMMARY: LOAD TYPE CONNECTED EM.D. CALCULATED 20 CONNECTED PHASE LOADING LIGHTING LTG 0.00 KVA RESIDENT LTG / RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 0.00 KVA REMAINING MOTORS MTR 0.00 KVA GEN PURPOSE RECPT REC 40.00 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 0,00 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 40.00 KVA 111.03 AMPS ,LOAD TYPE NOTES: 0.00 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA (125 %) 0.00 KVA (100%) 25.00 KVA ( 50% > 10KVA) 0.00 KVA (100 %) 0.00 KVA (100 %) 0.00 KVA (100%) 0.00 KVA 0 100% - 0.00 KVA 0 65% 25.00 KVA 69.39 AMPS AT INDICATED DEMAND AT 100% PHASE A: 14.00 KVA PHASE B: 14.00 KVA PHASE C: 12.00 KVA 1 1 GENERAL NOTES: 1 1 FLAG NOTES: 78 'COMB' = COMBINATION LOAD TYPES ON INDICATED CIRCUIT "RES" = RESIDENTIAL LTG /RECPT OR SMALL APPLIANCE LOAD TAKEN 'MISC' = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT r /SEPARATE PERMIT REQUIRED FOR; LV Mechanical ❑ Electrical CY Plumbing 31 Gas Piping City of Tukwila ilLONG DIVISION LIAR 14 NO( PANEL SCHEDULE PANEL SCHEDULE ELECT RM VOLTS: 208 Y/ 120 P 3 AIC RATING: 14,000 FEED- THROUGH LUGS NEUTRAL: 100% W: 4 PANEL: HPL2 LOCATION: ELECT RM VOLTS: 208 Y/ 120 P 3 AIC RATING: 14,000 NEUTRAL: 100% W: 4 CIRCUIT DESCRIPTION FLUSH AMP: 100 MLO X MCB MOUNT: © SURFACE • TYPE: EXISTING NEW el STYLE: FED FROM: PANEL HPL1 SEC I CIR CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P ELEV. PIT #1, RM 100, REM MON. (SOURCE= PNL 2L2L- 3A -23) CIR # P H CIR # P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION 20 1.00 REFRIG - RM 121A (SOURCE = PNL 2L2C -2) KITCH 1.00 20 1 20 43 A B C A B C A B C A 44 2 20 0.10 MISC SPACE - MISC REC - RM 121A (SOURCE = PNL 2L2C -4) REC 1.00 20 1 - 45 46 MISC - CAC 1 -5, MIS, RM 136A (SOURCE= 2L2A -3A- 15,17) MISC SPACE 20 2 DISHWASHER - RM 121A (SOURCE = PNL 2L2C -6) KITCH 1.00 20 1 MTR 47 48 MISC 0.05 - - SPACE 10 - GARBAGE DISPOSAL - RM 121A (SOURCE = PNL 2L2C -8) MIR 1.00 20 1 MISC 49 50 2 11 12 2 SPACE 1.91 MIR REC - RM 121A (SOURCE = PNL 2L2C -10) REC 0.50 20 1 - 51 52 - - 1.91 MIR SPACE VAV 1 -37 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A -3A- 25,27) MISC VENDING MACHINES - RM 121A (SOURCE = PNL 2L2C -12) MISC 0.50 20 1 2 53 54 MIR ACC -04 - AIR INTAKE TUNNEL 153 (SOURCE= PNL 2L2A -3B- 39,41) - MISC SPACE - - VENDING MACHINES - RM 121A (SOURCE = PNL 2L2C -14) MISC 0.50 20 1 MIR 55 56 MISC 0.50 20 2 SPACE 20 1 REC - RM 121A (SOURCE = PNL 2L2C -16) REC 0.72 20 1 MISC 57 58 - 21 22 1 SPACE 0.74 COMB REC - PHASE 3 COLUMNS (SOURCE = PNL 2L2C -32) REC 0.18 20 1 2 59 60 1 20 0.54 COMB SPACE - MISC REC - PHASE 3 COLUMNS (SOURCE = PNL 2L2C -34) REC 0.18 20 1 2 61 62 MISC FPVAV 1 -16 (SOURCE= PNL 2L2B- 32,34) VAV 1 -34 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A -3A- 33,35) MISC SPACE 20 2 SPARE IN J -BOX - WEST DOOR SHIP /RX (SOURCE = PNL 2L2C -36) 28 - 20 1 MISC 63 B C A B 64 0.40 - - 29 SPACE 1 20 SHREDDER - RM 114 (SOURCE = PNL 2L2C -39) MISC 1.00 20 1 0,90 65 66 31 32 1 20 SPACE LTG SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -16) COPIER - RM 114 (SOURCE = PNL 2L2C -41) MISC 1.00 20 1 33 67 68 20 1.80 LTG SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -18) SPACE MISC 0.20 REC - RM 160 (SOURCE= PNL 2L2E -8) REC 0.36 20 1 20 69 70 SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -30) GARAGE DOOR B - RM 125 (SOURCE= PNL 2L2A- 3B -28) MISC 0.20 SPACE 1 37 REC - RM 159 (SOURCE= PNL 2L2E -12) REC 0.36 20 1 HEAT TRACE NEXT TO RN 1 -20 (SOURCE= PNL 2L28 -A -23) 71 C A B C A 72 20 1 39 40 SPACE 20 8,30 VENDING MACHINES - RM 121A (SOURCE = PNL 2L2E -18) MISC 0.50 20 1 20 73 74 42 1 20 7.00 SPACE SPARE REC - RM 121A (SOURCE = PNL 212E -28) REC 1.00 20 1 75 76 1.00 31 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS SPACE 20 LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED REC - RM 121A (SOURCE= PNL 2L2E -30) REC 1.00 20 1 1 1 77 78 FLAG NOTES: 1.00 'COMB' = COMBINATION LOAD TYPES ON INDICATED CIRCUIT 'RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN 'MISC = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT 33 SPACE B SPARE 20 1 79 80 1.50 SPACE 35 MECH EWt1 -3 JANTOR STORAGE SPARE 20 2 20 1 81 B 82 FD THRU NO SPACE 37 SPARE A " 20 1 12.5 83 C 84 DBL LUG. 0.18 SPACE 39 OUTLET BELOW PANB. B 20 1 0.2 1.5 TOR YES ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS 41 C 20 1 LOAD SUMMARY: LOAD TYPE CONNECTED E.M.D. CALCULATED CONNECTED PHASE LOADING 0.0 0.0 LIGHTING LTG 0.00 KVA RESIDENT LTG / RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 1.00 KVA REMAINING MOTORS MIR 0.00 KVA GEN PURPOSE RECPT REC 5.30 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 3.50 KVA HEATING MISC 0.00 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 2.00 KVA TOTALS 11.80 KVA 32.75 AMPS LOAD TYPE NOTES: 0.00 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 1.25 KVA (125 %) 0.00 KVA (100 %) 5.30 KVA ( 50% > 10KVA) 0.00 KVA (100 %) 3.50 KVA (100 %) 0.00 KVA (1009 ) 0.00 KVA 0 100% 1.30 KVA 0 65% 11.35 KVA 31.50 AMPS AT INDICATED DEMAND AT 100% PHASE A: 4.18 KVA PHASE B: 3.58 KVA PHASE C: 4.04 KVA 1 1 GENERAL NOTES: FLAG NOTES: "COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT 'RES' = RESIDENTIAL LTG /RECPT OR SMALL APPUANCE LOAD TAKEN "MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT r /SEPARATE PERMIT REQUIRED FOR; LV Mechanical ❑ Electrical CY Plumbing 31 Gas Piping City of Tukwila ilLONG DIVISION LIAR 14 NO( PANEL SCHEDULE PANEL: HPL3 SEC I LOCATION: ELECT RM VOLTS: 208 Y/ 120 P 3 AIC RATING: 14,000 FEED- THROUGH LUGS NEUTRAL: 100% W: 4 AMP: 300 MLO MCB X MOUNT: © SURFACE • FLUSH TYPE: EXISTING NEW © STYLE: FED FROM: PANEL HDHP VIA 112.5kVA XFMR CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR P H CIR P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION ELEV. PIT #1, RM 100, REM MON. (SOURCE= PNL 2L2L- 3A -23) REC 0.54 20 1 1 A B C A B C A B C A B C A B C A. B C A B C 2 1 20 1.00 LTG SPARE TO 1ST FLOOR FSD (SOURCE= PNL 2L2A- 3B -35) UNIT HEATER 01 LOADING DOCK (SOURCE= PNL 2L2L- 3A -1,3) MISC 0.50 20 2 3 4 2 20 0.10 MISC VAV 1 -4 - RM 121A (SOURCE= PNL 2L2A- 3B- 20,22) - MISC 0.50 - - 5 6 - - 0.10 MISC - CAC 1 -5, MIS, RM 136A (SOURCE= 2L2A -3A- 15,17) MISC 0.05 20 2 7 8 2 20 0.60 MTR ACC -04 - AIR INTAKE TUNNEL 153 (SOURCE= PNL 2L2A -3B- 23,25) - MISC 0.05 - - 9 10 - - 0.60 MTR - VAV 1 -35 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A- 3A- 22,24) MISC 0.50 20 2 11 12 2 20 1.91 MIR ACC -04 - AIR INTAKE TUNNEL 153 (SOURCE= PNL 2L2A -3B- 38,40) - MISC 0.50 - - 13 14 - - 1.91 MIR - VAV 1 -37 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A -3A- 25,27) MISC 0.45 20 2 15 16 2 20 1.06 MIR ACC -04 - AIR INTAKE TUNNEL 153 (SOURCE= PNL 2L2A -3B- 39,41) - MISC 0.45 - - 17 18 - - 1.06 MIR - VAV 1 -32 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A -3A- 26,28) MISC 0.50 20 2 19 20 1 30 2.80 MISC HEAT TRACE NEXT TO Rill 1 -20 (SOURCE= PNL 2L2A -A -4) - MISC 0.50 - - 21 22 1 20 0.74 COMB ELEVATOR CAB LIGHTS (SOURCE= PNL 2L2A -A -36) VAV 1 -36 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A -3A- 29,31) MISC 0.30 20 2 23 24 1 20 0.54 COMB ELEVATOR MACH. RM LIGHTS, REC (SOURCE= PNL 2L2A -A -38) - MISC 0.30 - - 25 26 2 20 0.40 MISC FPVAV 1 -16 (SOURCE= PNL 2L2B- 32,34) VAV 1 -34 OPEN OFFICE RM 114 (SOURCE= PNL 2L2A -3A- 33,35) MISC 0,40 20 2 27 28 - - 0.40 MISC - - MISC 0.40 - - 29 30 1 20 1.80 LTG SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -14) ELEV 12 & 13 PIT UTES & REC (SOURCE= PNL 2L2A -3B -1) REC 0,90 20 1 31 32 1 20 1.80 LTG SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -16) HW CIRC PUMP - RM 137 (SOURCE= PNL 2L2A- 3B -18) MW 0.10 20 1 33 34 1 20 1.80 LTG SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -18) GARAGE DOOR A - RM 125 (SOURCE= PNL 212A- 3B -26) MISC 0.20 20 1 35 36 1 20 1.80 LTG SHIPPING & RECEIVING (SOURCE= PNL 2L2B- 3B -30) GARAGE DOOR B - RM 125 (SOURCE= PNL 2L2A- 3B -28) MISC 0.20 20 1 37 38 1 30 2.80 MISC HEAT TRACE NEXT TO RN 1 -20 (SOURCE= PNL 2L28 -A -23) ROLL -UP DOOR (SOURCE= PNL 2L2A- 3B -30) MISC 0.20 20 1 39 40 1 20 8,30 COMB SPARE MAG. DOOR HOLDERS - 1ST FLR (SOURCE= PNL 2L2A- 3B -34) MISC 0.50 20 1 41 42 1 20 7.00 COMB SPARE 1.0 8.3 :'' 1.00 31 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS A 20 LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED ! ' CONNECTED PHASE LOADING LIGHTING LTG 9.44 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPLIANCE RES 0.00 KVA LARGEST MOTOR 4.50 KVA REMAINING MOTORS MTR 28.54 KVA GEN PURPOSE RECPT REC 1.98 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 1.80 KVA HEATING MISC 30.60 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 76.86 KVA 213.34 AMPS /DAD TYPE NOTES: 11.80 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 5.63 KVA (125 %) 28.54 KVA (100 %) 1.98 KVA ( 50% > 10KVA) 0.00 KVA (100 %) 1.80 KVA (100%) 30.60 KVA (100 %) 0.00 KVA 0 100% 0.00 KVA 0 65% 80.35 KVA 223.02 AMPS AT INDICATED DEMAND AT 100% PHASE A: 31.35 KVA PHASE B: 20.70 KVA PHASE C: 24.81 KVA 1 1 GENERAL NOTES: FLAG NOTES: 1.00 'COMB' = COMBINATION LOAD TYPES ON INDICATED CIRCUIT 'RES" = RESIDENTIAL LTG/RECPT OR SMALL APPLIANCE LOAD TAKEN 'MISC = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT PANEL SCHEDULE PANEL HPL3 SEC 11 LOCATION: ELECT RM VOLTS: 208 Y/ 120 P 3 AIC RATING: 14,000 NEUTRAL 100% W: 4 AMP: 300 MLO X MCB • MOUNT: © SURFACE • FLUSH TYPE: EXISTING NEW © STYLE: FED FROM: PANEL HPL3 SEC I VIA FEED - THROUGH CIRCUIT DESCRIPTION LOAD TYPE LOAD KVA CKT BKR P CIR P H CIR P CKT BKR LOAD KVA LOAD TYPE CIRCUIT DESCRIPTION SEWAGE EJECTION PUMP (SOURCE= PNL 2L2C- 1,3,5) MTR 1.50 20 3 1 A B C A B C A B C A B C A B C A1. B C A B' ,C., 2 2 20 1.00 LTG PARKING LOT LIGHTS (SOURCE= PNL 2L2E -25) - MTR 1.50 - - 3 4 - - 1.00 LTG - - MTR 1.50 - - 5 6 1 20 0.10 MISC PARKING LOT IRRIGATION (SOURCE= PNL 2L2E -29) EXHAUST FAN 1C - 1ST FLOOR RR'S (SOURCE= PNL 2L2C -37) MTR 1.60 20 1 7 8 1 20 0.10 MISC SPRINKLER CONTROL (SOURCE= PNL 2L2E -36) HEAT PUMP - SECURITY RM 1ST FLR (SOURCE= PNL 2L2C- 13,15) MISC 0.10 15 2 9 10 120 1.00 SPACE - MISC 0.10 - - 11 12 SPACE CAC 1 -3 (SOURCE= PNL 2L2C- 18,20) MTR 0.10 20 2 13 14 B SPACE - MIR 0.10 - - 15 16 1.50 11 SPACE ACC -06 (SOURCE= PNL 2L2C- 19,21) MTR 1.70 20 2 17 18 1.5 12.5 WIRE 4 SPACE - MTR 1.70 - - 19 20 1.5 12.5 SPACE CAC 1 -2 (SOURCE= PNL 2L2C- 22,24) MTR 0.05 20 2 21 22 15 NECH FUTURE SUMP ELEV #1 B SPACE - MTR 0.05 - - 23 24 A.I.C.: CU SPACE CAC 1 -1 (SOURCE= PNL 2L2C- 26,28) MTR 0.75 20 2 25 26 1.5 SPACE - MTR 0.75 - - 27 28 MECH FUTURE SLNP ELEV #2 A 20 2 SPACE SUMP PUMP - SPRINKLER ROOM 160 (SOURCE= PNL 2L2C- 7,9,11) MTR 1.50 20 3 29 - -3O 1.50 21 SPACE - MTR 1.50 - - 31 32. - 3R SPACE - MTR 1.50 - - 33 . ••34 2 SPACE HEAT TRACE NEXT TO RN 1 -20 (SOURCE= PNL 2L2C -A -8) MISC 2.80 30 1 35 , F 25 A SPACE HEAT TRACE NEXT TO RTU 1 -20 (SOURCE= PNL 2L2D -A -10) MISC 2.80 30 1 37 38 3 100 7.00 COMB PANEL HPL4 FAN - PENTHOUSE (SOURCE= PNL 717E -2) MIR 0.50 - • •20. _ 1 ... 39 •- 40 - - 8,30 COMB - SPARE 20 1 41 ` 4 - - 7.00 COMB - 1.0 8.3 :'' 1.00 31 ESTIMATED MAXIMUM DEMAND (EMD) CALCULATIONS A 20 LOAD SUMMARY: LOAD TYPE: CONNECTED E.M.D. CALCULATED ! ' CONNECTED PHASE LOADING LIGHTING LTG 2.00 KVA RESIDENT LTG/RECPT RES 0.00 KVA SMALL APPUANCE RES 0.00 KVA LARGEST MOTOR 4.50 KVA REMAINING MOTORS MTR 21.30 KVA GEN PURPOSE RECPT REC 0.00 KVA COMPUTER RECPT MISC 0.00 KVA EQUIP /OTHER MISC 1.20 KVA HEATING MISC 17.60 KVA ELEVATOR ELEV 0.00 KVA KITCHEN EQPT KITCH 0.00 KVA TOTALS 46.60 KVA 129.35 AMPS LOAD TYPE NOTES: 2.50 KVA (125 %) 0.00 KVA ( 100/35/25 %) 0.00 KVA ( 100/35/25 %) 5.63 KVA (125 %) 21.30 KVA (100 %) 0.00 KVA ( 50% > 10KVA) 0.00 KVA (100%) 1.20 KVA (100%) 17.60 KVA (100 %) 0.00 KVA 0 100% 0.00 KVA 0 65% 48,23 KVA 133.86 AMPS AT INDICATED DEMAND AT 100% PHASE A: 18.05 KVA PHASE 8: 13.80 KVA PHASE C: 14.75 KVA 1 1 GENERAL NOTES: FLAG NOTES: 1.00 'COMB" = COMBINATION LOAD TYPES ON INDICATED CIRCUIT 'RES' = RESIDENTIAL LTG/RECPT OR SMALL APPUANCE LOAD TAKEN 'MISC" = EQUIP, COMPUTER REC OR HTG LOAD ON INDICATED CIRCUIT APPROVED P! /TO r.P C: CA -r'O»9 coat t ti'7" r" C"" HOED MODIFIED OR ALTERED Wf HOUT AUTHORIZATION FROM THE BUILDING OFFIO!AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS 31_13„' :CT TO FIELD INSPEOTIONS F L C Permit No Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy • nd c nditions is acknowledged: By �1� y� 0 frDatLZ. City of Tukwila BUILDING' DIVISION REVISIONS No changes shall be made to the mope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j Public Works, Building Division PERMIT NUMBER 0 Appro. 8 0 ._._Dater(I&q 'EATAC RECEIVED Crrr OF TUKVVILA APR 10 2008 PERMIT CENTER -ELOS'39/2 FILE COPY DATACEN TER VECA E L E C T R I C 5614 7th Ave. South Seattle, WA 98108 Ph 206 436 -5200 Fx 206 - 763 -0505 BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 202 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 34303 6'414 STEW) EXPIRES 1 -17 -06 z 0 w~ w0 ft < 0 00 wZ 0 u) 0 U 1.014ED f9 010e C°V1101.r. kAAI Ot 10011a TU KW I LA, WA 98168 REV # DATE REVIEW SET 3/09/06 REVIEW SET 3/15/06 REVIEW SET 9/1/06 PERMIT 1/18/08 DRAWN CHECKED DATE BW BW 9/1/06 PANEL SCHEDULES E1.1 VECA Electric PANEL: HPL4 FEEDTHRU ROOM HOUSE POWER DST AREA LOADS FROM FFL3 -2 A B C RCFr LTG EQP FEAT CKT DESCRIPTION PH AMP P KVA AMPS KVA AMPS KVA AMPS 0.50 1 RECPrRM121A VENDING MACHNE A 20 1 0.5 4.2 0.18 3 RECPT RM121A COUNTERTOP B 20 1 0.2 1.5 AMP: 125 0.18 5 RECPTRM121A COUNTERTOP C 20 1 0.2 1.5 VOLTS: 120 1.00 7 MECH VAV 2 -21 LOBBY A 20 2 1.0 8.3 208 1.00 9 B 1.0 8.3 Ftt 3 1.50 11 MECH FUTURE SUUP e_EV #3 C 20 2 1.5 12.5 WIRE 4 1.50 13 A 1.5 12.5 BUS: AL 1.50 15 NECH FUTURE SUMP ELEV #1 B 20 2 1.5 12.5 A.I.C.: CU 1.50 17 C 1.5 12.5 WO: YES 1.50 19 MECH FUTURE SLNP ELEV #2 A 20 2 1.5 12.5 MAIN CB 1.50 21 B 1.5 12.5 3R 1.00 23 MECH VAV 1 -27 RM 121A C 20 2 1.0 8.3 FLUSH. 1.00 25 A 1.0 8.3 SURF: YES 1.00 27 NECH VAV 1 -23 RM 122 SHP /REC B 20 2 1.0 8.3 1.00 29 C " 1.0 8.3 1.00 31 MECH SEWER EJECTION PUVP A 20 2 1.0 8.3 K3 GF'D. 1.00 33 B 1.0 8.3 200% N: 1.50 35 MECH EWt1 -3 JANTOR STORAGE C 20 2 1.5 12.5 FD THRU NO 1.50 37 A " " 1.5 12.5 DBL LUG. 0.18 39 OUTLET BELOW PANB. B 20 1 0.2 1.5 TOR YES 41 C 20 1 0.0 0.0 6TM 0.50 2 MECH FAN PENTHOUSE A 20 1 0.5 4.2 PANEL T.C.L. 0.50 4 NECHFASRNKLBR VALVE RM159 B 20 1 0.5 4.2 LOAD (kVA) 0.50 6 r:=oy s ,:'=� z .:•a: 7: > -;. �6lo C 20 1 0.5 4.2 ,RCPT 3.7 0.80 �10 GEN 52A BATT CHARGER Ilk\ A 20 1 0.8 6.7 LTG 0.0 0.80 GEN 52B BATT CHARGER B 20 1 0.8 6.7 EQP 24.0 0.40 12 GEN 52A DAY TANK J C 20 1 0.4 3.3 HEAT 6.0 0.40 i 14 GEN 52B DAY TANK A 20 1 0.4 3.3 1.26 7 16 " •' ' B 20 1 1.3 10.5 ' TOTAL 33.7 I 1.08 :i~.�: ��nwriv9w - C 20 1 1.1 9.0 0.18 20 RECPT GEN RM 52 A 20 1 0.2 1.5 FEEDER T.C.L. • • 0.18 s :D -.r • B 20 1 0.2 1.5 r LOAD (kVA) 1.50 24 GEN 52A BLOCK HEATER C 20 2 1.5 1 '4.5 RCPT 3.7 1.50 26 " A " 1.5 12.5 �' LTG 0.0 1.50 28 GEN 52B BLOCK I -EATER B 20 2 1.5 12.5 EQP 24.0 1.50 30 C 1.5 12.5 HEAT 6.0 A 20 1 0.0 0.0 34 B 20 1 0.0 0.0 TOTAL 33.7 36 C 20 1 0.0 0.0 LG MrR 38 A 20 1 0.0 0,0 FEEDER DEMAND 40 B 20 1 0.0 0.0 kVA 33.7 0.10 42 SO D MONITOR PANEL C 20 1 0.1 0.8 AMPS 931 A 0.0 0.0 - B 0.0 0.0 - C " 0.0 0.0 3.7 0.0 24.0 6.0 MFG/CB: Remarks: KVA/AMPS: 11.4 94.8 10.6 88.3 11.8 98.0 01/18/08 0.7 0.0 9.2 1.5 A 1.8 0.0 7.3 1.5 B 1.3 0.0 7.5 3.0 C SDC COMMON LOAD - 1/18/08 APPROVED P! /TO r.P C: CA -r'O»9 coat t ti'7" r" C"" HOED MODIFIED OR ALTERED Wf HOUT AUTHORIZATION FROM THE BUILDING OFFIO!AL, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE APPROVED PLANS AND IS 31_13„' :CT TO FIELD INSPEOTIONS F L C Permit No Plar review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy • nd c nditions is acknowledged: By �1� y� 0 frDatLZ. City of Tukwila BUILDING' DIVISION REVISIONS No changes shall be made to the mope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j Public Works, Building Division PERMIT NUMBER 0 Appro. 8 0 ._._Dater(I&q 'EATAC RECEIVED Crrr OF TUKVVILA APR 10 2008 PERMIT CENTER -ELOS'39/2 FILE COPY DATACEN TER VECA E L E C T R I C 5614 7th Ave. South Seattle, WA 98108 Ph 206 436 -5200 Fx 206 - 763 -0505 BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 202 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 34303 6'414 STEW) EXPIRES 1 -17 -06 z 0 w~ w0 ft < 0 00 wZ 0 u) 0 U 1.014ED f9 010e C°V1101.r. kAAI Ot 10011a TU KW I LA, WA 98168 REV # DATE REVIEW SET 3/09/06 REVIEW SET 3/15/06 REVIEW SET 9/1/06 PERMIT 1/18/08 DRAWN CHECKED DATE BW BW 9/1/06 PANEL SCHEDULES E1.1 AREA OF WORK L_J! (E) 4000A SWITCHBOARD FLAG NOTES: INSTALL NEW 1200A BREAKER IN EXISTING UNUSED SWITCHBOARD. ROUTE CONDUIT UP TO RE —FEED EXISTING ELEVATOR. CONTINUE UP TO SECURITY PANELS. ® CONNECT TO EXISTING POWER MONITORING. CUT OVER EXISTING HOUSE CIRCUITS TO NEW PANELS. SEE PANEL SCHEDULES FOR DETAILS. © UP TO EXISTING GENERATOR RASP PANEL. Ixna -IO xwo-w x wxu-w wxl-o 1 0 1 0 1 I 0 1 - w O I O I ... IMII! -w C> Inhl-w Maz—n 111111111111111-lo 1 0 1 0 1 I O I O 1 O O i L0w 1 In0 ul -w O I O B 1 "C -3 #3 & 1 #8G 1"C-3#3 & 1 #8G (4) 3 "C- 4 #350kcmil & 1 #3 /OG (6) 1"C-4#3 — 1Y "C -3 #1/0 1, "C -3 #1/0 & 1 #8G & 1 #6G & 1 #6G ATS PANEL HPHD rT1 rT, rT1 rT, : -' r-, .. .�, L_J L_J L_J L_J -A L_J L_J L_J L_J L_J 1 "C -3 #3 & 1 #8G �m 7AREA OF WORK DISCONNECT EXISTING GENERATOR REMOVE CONDUIT AND WIRE GENERATOR FIRST FLOOR POWER PLAN SCALE: 1/16" = 1' -0" 0 4' 8' 16' 32' MAR 1 4.2009 001AG £Lo8 39d RECEIVED CITY OF TUKWILA APR 10 2008 PERMIT CENTER 12/06/07 RECORD DRAWING EY DATACEN TER VPVECA 'E L EC T R IC 5614 7th Ave. South Seattle, WA 98108 Ph 206 436 -5200 Fx 206 - 763 -0505 BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 202 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 EXPIRES 1 -17 -06 z 0 w z 0 <Q <O wz m� 2 0 U TU KW I LA, WA 98168 REV # DATE REVIEW SET 3/09/06 REVIEW SET 3/15/06 REVIEW SET 9/1/06 PERMIT 1/18/08 DRAWN BW CHECKED BW DATE 9/1/06 FIRST FLOOR POWER PLAN E2.1 PB - - - P/r /c - -- - S v8o S&ASSH V A. O\S CIRCUITING SYMBOLS NEW WIRING. HASH MARKS INDICATE NUMBER OF #12 AWG WIRE UNLESS NOTED OTHERWISE, NO HASH MARKS INDICATES TWO WIRES PLUS GROUND UNLESS NOTED OTHERWISE. LONG HASH MARKS DENOTES NEUTRAL. -1 INDICATES GROUND WIRE. INDICATES ISOLATED GROUND WIRE, WHERE SHOWN. NEW WIRING RUN IN OR BELOW SLAB OR BELOW GRADE. EXISTING RACEWAY OR WIRING (IF HASH MARKS ARE SHOWN PULL NEW CONDUCTORS) RACEWAY STUB -OUT WITH BUSHING HOME RUN TO PANEL OR LOCATION NOTED CIRCUIT CONTINUATION JUNCTION BOX, CEILING /WALL PULL BOX HANDHOLE UNDERGROUND UTILITY SERVICE - POWER, TELEPHONE & CABLE AS INDICATED P/r' /c OVERHEAD UTILITY SERVICE - POWER, TELEPHONE Sc CABLE AS INDICATED C -0 POWER POLE /GUY 2-- G 0 GROUND WIRE POWER SYMBOLS ❑' DISCONNECT SWITCH zJ FUSED DISCONNECT i0' MOTOR, SINGLE PHASE ® EQUIPMENT CONNECTION CONTACTOR MOTOR RATED SWITCH GENERATOR REMOTE ANNUNCIATOR PANEL PANEL - 208/120 VOLT SYSTEM, +6' TO TOP U.N.O. ® PANEL - 480 VOLT SYSTEM, +6' TO TOP U.N.O. 3RAFI Lighting Summary LTG -SUM Note new automatic davlighting. occupancy sensor, and other control requirements of Section 1513. as applicable. June 2002. - KJM /MAK Project Info Project Address 3355 S. 120TH PLACE No changes are being made to the lighting Date 1/18/2008 TvrcwlLA, WA 9816e RMS 107, 108 For Building Department Use 0.. BO 84 91. 0 Applicant Name: VECA ELECTRIC RM 108 Applicant Address: 5614 7TH AVE. SOUTH, SEATTLE, WA 98108 Applicant Phone: 206 -436 -5229 .3660. 0 Project Description ❑ New Building ❑ Addition Alteration E] Bldg. >5,000 sq.ft. (auto shutoff req'c 0 Plans Indudec Indicate controls (SEC Section 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Clear Alteration Exceptions (check appropriate box) • No changes are being made to the lighting II < 60% of fixtures new, installed lighting wattage not increased and Table 15 -1 use is not chanced Maximum Allowed Lighting Wattage (Interior) Location (floor/room no.) Occupancy Description Allowed Watts per ft2 "" Area in fc2 Allowed x Area RMS 107, 108 MECHANICAL & ELECTRICAL ROOMS 0.. BO 84 91. 0 6792_:8 RM 108 8 FT. 4 -LAMP FLUORESCENT 30 122.0 .3660. 0 1/2" (4) - #12, 1 # 12 G 20/15 20C3 (1) 1/2" 1/2" (3) - #12, 1 # 12 G 20/20 20C4 (1) 1/2" 1/2" (4) - #12, 1 # 12G 20/20 25C3 (1) 1/2" 1/2" (3) - #10, 1 # 10G 30/25 25C4 (1) 1/2" 3/4" (4) - #10, 1 # 10G 30/25 30C3 (1) 1/2" 1/2" (3) - #10, 1 # 100 30/30 30C4 (1) 1/2" 3/4" (4) - #10, 1 # 10G 30/30 35C3 (1) 3/4" 3/4" (3) - #8, 1 # 10G 50/35 35C4 (1) 3/4" 1" (4) - #8, 1 # 10G 50/35 40C3 (1) 3/4" 3/4" (3) - #8, 1 # 10G 50/40 40C4 (1) 3/4" '" From Table 15 -1 over) - document all exceptions on form LTG -LPA Totals 8491.0 6792.8 Notes on Proposed Lighting Wattage: 1. Use manufacturer's listed maximum input wattage. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used 2. Include exit lights exceeding 5.0 watts per fixture. Proposed Lighting Wattage (Int.) 3. List all fixtures. For exempt lighting, note exception on applicable fixtures. Location (floor/room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed RM 107 8 FT. 4 -LAMP FLUORESCENT 12 122.0 1464.0 RM 108 8 FT. 4 -LAMP FLUORESCENT 30 122.0 .3660. 0 1/2" (4) - #12, 1 # 12 G 20/15 20C3 (1) 1/2" 1/2" (3) - #12, 1 # 12 G 20/20 20C4 (1) 1/2" 1/2" (4) - #12, 1 # 12G 20/20 25C3 (1) 1/2" 1/2" (3) - #10, 1 # 10G 30/25 25C4 (1) 1/2" 3/4" (4) - #10, 1 # 10G 30/25 30C3 (1) 1/2" 1/2" (3) - #10, 1 # 100 30/30 30C4 (1) 1/2" 3/4" (4) - #10, 1 # 10G 30/30 35C3 (1) 3/4" 3/4" (3) - #8, 1 # 10G 50/35 35C4 (1) 3/4" 1" (4) - #8, 1 # 10G 50/35 40C3 (1) 3/4" 3/4" (3) - #8, 1 # 10G 50/40 40C4 (1) 3/4" Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 5124.0 XX NL 1 1 LIGHTING SYMBOLS FLUORESCENT FIXTURE, TYPE AS INDICATED ON PLAN "XX" INDICATES FIXTURE TYPE, "NL" INDICATES 24HR NIGHTLIGHT OPERATION FLUORESCENT STRIP FIXTURE, DRAWN TO SCALE BATTERY PACK EMERGENCY LIGHTING UNIT BATTERY POWERED EXIT SIGN - ARROWS AS INDICATED, SHADING INDICATES SIDE(S) ILLUMINATED. TRANSFER SWITCH RISER SYMBOLS 2 - CIRCUIT BREAKER -« »}- DRAW OUT CIRCUIT BREAKER FEEDER DESIGNATION --0----(1111- FUSED SWITCH = GROUND PANEL �IIS PANEL GROUND FAULT CIRCUIT BREAKER TRANSFORMER lr CABLE TO BUS CONNECTION AVAILABLE SHORT CIRCUIT CURRENT METER UPS PRI v BREAKER FOR FUTURE FEEDER ARY BUS 52A DIST. SWBD "HDP -52A" I4000A IBUS 480V- 30 -3W -65 KAIC 0 1200AT 8 1600AT 8 50AT O 50AT )3P 0)3P 0)3P 0)3P ABBREVIATIONS AC INDICATES ABOVE COUNTER MOUNTING AT +4" ABOVE BACKSPLASH OR +6" ABOVE COUNTERS WITHOUT BACKSPLASH AFF ABOVE FINISHED FLOOR A, AMP AMPERE ATS AUTOMATIC TRANSFER SWITCH AWG AMERICAN WRE GAGE (BTS) BASE TRANSFER STATION CB CIRCUIT BREAKER CKT CIRCUIT DED DEDICATED DW DISHWASHER (E) EXISTING EWC ELECTRIC WATER COOLER FA FIRE ALARM FBOIC FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR G, GND GROUND GFI, GFCI GROUND FAULT CIRCUIT INTERRUPTER HT HEIGHT HWT HOT WATER TANK IH INSTA HOT J -BOX JUNCTION BOX r-1 r - - -� i L_ - - - J /// XXX xx -x FLAG NOTE MW MICROWAVE - COORDINATE MOUNTING HEIGHT N NEUTRAL P POLE PNL PANEL (R) RELOCATED (INDICATES EXISTING EQUIPMENT TO BE RE- INSTALLED AS SHOWN) RO RACEWAY ONLY RECPT RECEPTACLE REF REFRIGERATOR S SAFETY TYPE SWBD SWITCHBOARD TELCO TELEPHONE COMPANY TELE TELEPHONE TR TELEPHONE RISER TYP TYPICAL UC UNDERCABINET UNO UNLESS NOTED OTHERWISE ✓ VOLT W WIRE OR WATT 0 PHASE W/O WITHOUT WP WEATHERPROOF MISCELLANEOUS REVISION SYMBOL EXISTING EQUIPMENT OR DEVICE REMOVE EXISTING ELECTRICAL EQUIPMENT EQUIPMENT IDENTIFIER TYPICAL ROOM DETAIL REFERENCES: XX - INDICATES DETAIL NUMBER M - INDICATES THAT DETAIL IS MIRROR IMAGE OF REFERENCED LOCATION EY.Y - INDICATES SHEET WHERE DETAIL IS FOUND - DIRECTION OF ARROW INDICATES PLAN ORIENTATION IN RELATION TO DETAIL PROPERTY LINE FENCING CABLE TRAY DRAWING INDEX EO - SYMBOLS AND ABBREVIATIONS, PARTIAL ONE -LINE RISER DIAGRAM E1.1 - PANEL SCHEDULES E2.1 - FIRST FLOOR POWER PLAN E2.2 - FIRST FLOOR DETAILS FLAG NOTES: o. INTERCEPT FEEDERS FROM EXISTING PMM. FEEDER SCHEDULE COPPER ID NO EMT RACEWAY PVC SCH, 40 WIRE COUNT & SIZE AMPACITY/ OCP SIZE NOTES 15C3 (1) 1/2" 1/2" (3) - #12, 1 # 12 G 20/15 15C4 (1) 1/2" 1/2" (4) - #12, 1 # 12 G 20/15 20C3 (1) 1/2" 1/2" (3) - #12, 1 # 12 G 20/20 20C4 (1) 1/2" 1/2" (4) - #12, 1 # 12G 20/20 25C3 (1) 1/2" 1/2" (3) - #10, 1 # 10G 30/25 25C4 (1) 1/2" 3/4" (4) - #10, 1 # 10G 30/25 30C3 (1) 1/2" 1/2" (3) - #10, 1 # 100 30/30 30C4 (1) 1/2" 3/4" (4) - #10, 1 # 10G 30/30 35C3 (1) 3/4" 3/4" (3) - #8, 1 # 10G 50/35 35C4 (1) 3/4" 1" (4) - #8, 1 # 10G 50/35 40C3 (1) 3/4" 3/4" (3) - #8, 1 # 10G 50/40 40C4 (1) 3/4" 1" (4) - #8, 1 # 10G 50/40 45C3 (1) 3/4" 3/4" (3) - #8, 1 # 100 50/45 45C4 (1) 3/4" 1" (4) - #8, 1 # 100 50/45 50C3 (1) 3/4" 3/4" (3) - #8, 1 # 100 50/50 50C4 (1) 3/4" 1" (4) - #8, 1 # 10G 50/50 60C3 (1) 3/4" 1" (3) - 0, 1 # 10G 65/60 60C4 (1) 1" 1" (4) - #6, 1 # 10G 65/60 70C3 (1) 3/4" 1" (3) - #6, 1 # 8G 65/70 70C4 (1) 1" 1" (4) - #6, 1 # 8G 65/70 80C3 (1) 1" 1 -1/4" (3) - #4, 1 # 8G 85/80 80C4 (1) 1 -1/4" 1 -1/4" (4) - #4, 1 # 8G 85/80 90C3 (1) 1" 1 -1/4" (3) - #4, 1 # 8G 85/90 90C4 (1) 1 -1/4" 1 -1/4" (4) - #4, 1 # 8G 85/90 100C3 (1) 1" 1 -1/4" (3) - #3, 1 # 8G 100/100 100C4 (1) 1 -1/4" 1 -1/4" (4) - #3, 1 # 8G 100/100 110C3 (1) 1 -1/4" 1 -1/4" (3) - #2, 1 # 6G 115/110 110C4 (1) 1 -1/4" 1 -1/2" (4) - #2, 1 # 6G 115/110 125C3 (1) 1 -1/4" 1 -1/4" (3) - #2, 1 # 6G 115/125 125C4 (1) 1 -1/4" 1 -1/2" (4) - #2, 1 # 6G 115/125 150C3 (1) 1-1/2" 1-1/2" (3) - #1/0, 1 # 6G 150/150 150C4 (1) 1-1/2" 2" (4) - #1/0, 1 # 6G 150/150 175C3 (1) 1 -1/2" 2" (3) - #2/0, 1 # 6G 175/175 175C4 (1) 2" 2" (4) - #2/0, 1 # 6G 175/175 200C3 (1) 2" 2" (3) - #3/0, 1 # 6G 200/200 200C4 (1) 2" 2" (4) - #3/0, 1 # 6G 200/200 225C3 (1) 2" 2" (3) - #4/0, 1 # 4G 230/225 225C4 (1) 2 -1/2" 2 -1/2" (4) - #4/0, 1 # 4G 230/225 250C3 (1) 2" 2" (3) - #4/0, 1 # 4G 230/250 250C4 (1) 2-1/2" 2-1/2" (4) - #4/0, 1 # 4G 230/250 300C3 (1) 2 -1/2" 2 -1/2" (3) - #300, 1 # 4G 285/300 300C4 (1) 2 -1/2" 3" (4) - #300, 1 # 4G 285/300 350C3 (1) 2 -1/2" 3" (3) - #400, 1 # 3G 335/350 350C4 (1) 3" 3" (4) - #400, t # 3G 335/350 400C3 (1) 2 -1/2" 3" (3) - #500, 1 # 3G 380/400 400C4 (1) 3" 3 -1/2" (4) - #500, 1 # 3G 380/400 450C3 (1) 3" 3 -1/2" (3) - #600, 1 # 2G 420/450 450C4 (1) 3 -1/2" 4" (4) - #600, 1 # 2G 420/450 500C3 (2) 2" 2 -1/2" (3) - #250, 1 # 2G 510/500 500C4 (2) 2 -1/2" 3" (4) - #250, 1 # 2G 510/500 600C3 (2) 2 -1/2" 2 -1/2" (3) - #300, 1 # 1G 570/600 600C4 (2) 2 -1/2" 3" (4) - #300, 1 # 1G 570/600 700C3 (2) 2 -1/2" 3" (3) - #400,1 # 1/00 670/700 700C4 (2) 3" 3" (4) - #400, 1 # 1/00 670/700 800C3 (2) 2 -1/2" 3" (3) - #500, 1 # 1 /OG 760/800 800C4 (2) 3" 3 -1/2" (4) - #500, 1 # 1/00 760/800 1000C3 (3) 2 -1/2" 3" (3) - #400, 1 # 2 /OG 1005/1000 1000C4 (3) 3" 3" (4) - #400, 1 # 2/00 1005/1000 1200C3 (4) 2 -1/2" 3" (3) - #350, 1 # 3 /OG 1240/1200 1200C4 (4) 3" 3" (4) - #350, 1 # 3 /OG 1240/1200 1300C3 (4) 2 -1/2" 3" (3) - #400, 1 # 4/00 1340/1300 1300C4 (4) 3" 3 -1/2" (4) - #400, 1 # 4/00 1340/1300 1500C3 (4) 3" 3" (3) - #500, 1 # 4 /0G 1520/1500 1500C4 (4) 3" 3 -1/2" (4) - #500, 1 # 4 /OG 1520/1500 1600C3 (5) 2 -1/2" 3" (3) - #400, 1 # 4 /OG 1675/1600 1600C4 (5) 3" 3 -1/2" (4) - #400, 1 # 4 /OG 1675/1600 2000C3 (6) 2 -1/2" 3" (3) - #400, 1 # 250G 2010/2000 2000C4 (6) 3" 3 -1/2" (4) - #400, 1 # 250G 2010/2000 2500C3 (7) 3" 3 -1/2" (3) - #500, 1 # 350G 2660/2500 2500C4 (7) 3" 3 -1/2" (4) - #500, 1 # 350G 2660/2500 3000C3 (8) 3" 3 -1/2" (3) - #500, 1 # 400G 3040/3000 3000C4 (8) 3" 3 -1/2" (4) - #500, 1 # 400G 3040/3000 3500C3 (10) 3" 3 -1/2" (3) - #500, 1 # 500G 3800/3500 3500C4 (10) 3" 3 -1/2" (4) - #500, 1 # 500G 3800/3500 4000C4 (11) 3" 3 -1/2" (4) -500, 1# 500G 4180/4000 4000C3 (11) 3" (3) -500, 1# 500 G 4180/4000 GENERAL NOTES 1. CIRCUIT TAG INDICATES NOMINAL CIRCUIT AMPS, CONDUCTOR MATERIAL (A = ALUMINUM, C = COPPER). AND NUMBER OF CONDUCTO S (EXCLUDING GROUND). EQUIPMENT GROUNDING CONDUCTORS ARE COPPER. 2. STANDARD OVERCURRENT PRGTECTIVE DEVICE RATING PER NEC 240 -6. - ASSUMES ADJUSTABLE TRIP CIRCUIT BREAKER. 3. WIRE AMPACITY REPRESENTS THE MAXIMUM CIRCUIT DESIGN AMPS AND IS BASED ON NEC TABLE 310 -16 WITH NO CORRECTION FACTORS FOR TEMPERATURE OR ADJUSTMENT REQUIRED FOR VOLTAGE DROP. 4. RACEWAY IS SIZED TO INCLUDE AN EQUIPMENT GROUNDING CONDUCTOR. "MAX SIZE IS BASED ON RIGID PVC CONDUIT, SCHEDULE 80. 5. UTILIZE RACEWAY AS EQUIPMENT GROUND PER NEC 250 -118. WHERE CONTINUOUS METALLIC RACEWAY IS NOT UTILIZED. PROVIDE EQUIPMENT GROUNDING CONDUCTOR. 6. CONDUIT AND WIRE MAY BE REPLACED WITH MC CABLE. ROOF 411111M111■ /1111b.. r 4000AT) - Y 1 1!I r E O 4000A r= 2500 KW 2750 KVA GENERATOR 52 -A Y�- (E) ELEVATOR #1 (E) ELEVATOR #2 I ' i LTJ 4, L_rJ II (E) ELEVATOR #3 r ,, 1 F PANEL S3A PANEL S3B MAR 14 ZOOS TAP BOX FOR ___),..PORTABLE LOAD BANK (10) 3.5 "C 3 -600, 350N, 5000 MCM CU L- - - - - -- �)4000AT Y AUTOMATIC TRANSFER CONTROL MODULE t 3P 00AT O)800AT 1 1 O)SOOAT 0)800AT 1 800ATO) 800AT0) 800ATO) (TYP.) 800AT o) 1300AT O) 800AT O) 800AT O) 800AT O) 800AT (E) AC -3 ON MEZZANINE lj LTJ 100C3 15003 PANEL S2A PANEL S2B _A THIRD FLOOR tAki CM p� 100i1a S1 SECOND FLOOR 225C3 1200A ATS 0 < i a s rn I 01 I 4 4 w U rn uJ U w U (E) 4000A SWITCHBOARD PANEL HDHP MLO - (4) 3 "C- 4 #350kcmil & 1 #3 /OG UPS 120kW 480V/30 BYPASS PMM 165kVA 208V/30 100C4 PANEL S1A PANEL S1B A /\ 10004 LTG 480/277V PANEL HPH1 SEC I 225A MLO PANEL HPH1 SEC II 225A MLO /at'," 10003 V LCP 75kVA XFMR III 480:120/208V PANEL HPL1 SEC I 225A MCB PANEL HPL1 SEC II 225A MLO 13c.es"? #4G = 2\250 /4 V PANEL HPL2 100A MLO s' 10004 112.5kVA XFMR Z�IS 480:120/208V 17503 #4G PANEL HPL3 SEC 1 300A MCB PANEL HPL3 SEC 11 300A MLO 22V 30004 /3 r. PANEL HPL4 100A MLO A 10004 RECEIVED CITY OF TUKWILA APR 101008 PERMIT CENTER FIRST FLOOR LOB 390 S BEY DATACEN TER VELA ' E L E C T R I C 5614 7th Ave. South Seattle, WA 98108 Ph 206 436 -5200 Fx 206 - 763 -0505 BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 202 tel: (206)223-6446 Seattle, Washington 98121 fax: (206)223-6465 EXPIRES 1 -17 -06 z 0 w~ z 0 2 om- Q DO >-z 02 ul 0 U TUKWILA, WA 98168 REV # DATE REVIEW SET 3/09/06 REVIEW SET 3/15/06 REVIEW SET 9/1/06 PERMIT 1/18/08 DRAWN CHECKED DATE BW BW 9/1/06 SYMBOLS AND ABBREVIATIONS EO 0 g 0 0 0 HPL4 -22 HPH12 -12 0 FUTURE UPS HPL4-22 0 HPH12 -12 HPH12 -12 FUTURE UPS 0 >0 In 0 3 :._ HPH12-12 1- 0 N -0 BATT CHGR HPL4 -8 1.5HP 480/3/3A 0 HPH12�Q- HPH12 -14 EF -2 1.5HP 480/3/3A 1 0 1 0 HtI -10 HPH12 -14 EF -3 1.5HP 460/3/3A y 0 0 0 0 °m v 0 go 1- 0 FUTURE SWBD HPH12 -12 HPH12 -12 FUTURE SWBD HPH12 -12 BATF CHGR HPL4 10 C QpHPL4 22 HPH12 -10 FB HPH12 -10 0� BLOCK HTR HPL4 -26 52A F8 HPH12 -10 1 0 _1 0 1 _ {-0-- —C- DAY TANK PUMP & CTRLS HPL4 -12 HPH12 -10 �- BLOCK HTR 52B HPL4 -30 HPH12 -14 EF -4 1.5HP 460/3/3A HPH12 -10 1 0 1 0 1 HPH12 -10 HPH12 -10 1 0 1 0 1 F8 HPH12 -10 1 0 1 0 1 HPH12 -10 1 0 1 0 1 F8 HPH12 -10 1 0 1 0 1 HPL4 -24 HPH12 -10 c N m MBP co Q Q d8W 0) a FUTURE UPS c -D (1) MBP D co m dRI 1n 0 HPL4 -22 FUTURE UPS HPH12 -12 H4PpL4 -22 HPH12 -12 FUTURE UPS HPH12 -10 1 0 1 0 1 DAY TANK PUMP - & CTRLS HPL4 -14 HPH12 -10 HPH12 -10 I-- 0-- I1"-0■4 HPL4-24 HPL4 -24 HPH12 -12 HVS -4A FRONT HPH12 -10 1 0 1 0 1 FRONT HVS -4B c -D N MBP co —DI Q m d8W !n a FUTURE UPS MBP co HPH12 -10 CO d811 0- 3000 KVA FUTURE UPS HPH12 -12 HPH12 -12 FUTURE UPS HPH12 -12 HPH12 -12 HPH12 -10 N C0 0 -1 0 0 FUTURE SWBD AREA OF WORK 0 v > 0 0 0 FUTURE UNIT SUBSTATION U HPH12- HPH12 -10 �O 1 3000 KVA HPH12 -10 1 0 1 0 1 FUTURE UNIT SUBSTATION HPL4 -24 HPH12 -10 41 HPH12 -10 1 O 1 O 1 HVS -4C FRONT HPH12 -10 1 0 1 0 1 FRONT HVS -4D HPH12 -10 1 0 1 0 1 HPH12 -10 1-0 1 0-1 FUTURE UNIT SUBSTATION 3000 KVA © HPH12 -10 HPH12 -10 1 0 1 0 1 FUTURE UNIT SUBSTATION 3000 KVA HPH12 -10 HPH12 -10 1 0 1 0 1 HPL4 -24 HPH12 -10 NEW FEEDER (4) 3 "C- 4 #350kcmil & 1 #3/0G REMOVE EXISTING CONDUIT & WIRE PROVIDE J -BOX INTERCEPT EXISTING FEEDER RECONNECT TO ATS GENERATOR ROM/ SCALE: 1/8" = 1' -0" V v ATS PANEL HPHD v v v v v v v v 0— PVIM SF1 SF1 U 1 n PANEL HPH1 (I & II) LTG CONTROL PANEL HPL4 PANEL HPL3 (I & II) T (1) 75kVA (1) 112.5kVA EXISTING / TO REMAIN PANEL HPL2' PANEL HPL1 HOUSE POWER DISTRIBUTION AREA SCALE: 1 /4" = 1' -0" 0 1' 2' 4' 8' 11AR 14 2009 RECEIVED CITY OF TUKWILA APR 10 2008 PERMIT CENTER ELoB 390 DATAC EN TER vVELA ' E L E C T R I C 5614 7th Ave. South Seattle, WA 98108 Ph 206 436 -5200 Fx 206 - 763 -0505 BrN Engineering, Inc. Electrical Consulting Engineering 2101 9th Avenue, Suite 202 tel: (206)223 -6446 Seattle, Washington 98121 fax: (206)223 -6465 EXPIRES 1 -17 -06 z 0 w ~' z w �? U2 < Q � O }' Z W 0 m cr) 0 U TUKWILA, WA 98168 REV # DATE REVIEW SET 3/09/06 REVIEW SET 3/15/06 REVIEW SET 9/1/06 PERMIT 1/18/08 DRAWN CHECKED DATE BW BW 9/1/06 FIRST FLOOR ELECTRICAL DETAILS E2.2