Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0425 - WESTFIELD SOUTHCENTER MALL - DAPHNE'S GREEK CAFE
DAPHNE'S GREEK CAFE 2600 SOUTHCENTER MALL FC -7 ELO8-425 Citylk Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -425 Issue Date: 05/29/2008 Permit Expires On: 12/08/2008 Tenant: Name: DAPHNE'S GREEK CAFE Address: 2600 SOUTHCENTER MALL FC -7 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: RYAN WATKINS Phone: 858 -784 -0811 Address: 6125 CORNERSTONE CT #100 , SAN DIEGO CA Contractor: Name: MERIT ELECTRIC INC Phone: 425- 775 -1356 Address: 19029 36 AV W STE D , LYNNWOOD WA Contractor License No: MERITEI044BQ Expiration Date: 01/18/2010 DESCRIPTION OF WORK: INSTALL NEW ELECTRICAL SYSTEM IN FOOD COURT RESTAURANT IN NEW MALL SPACE 7 -10 -08 REVISION #1 RECEIVED FROM TOM BUNCH. REVISION IS TO ADD FIRE ALARM SYSTEM TO THIS PERMIT. WER Value of Electrical: $16,200.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $451.00 2005 Date: (` i O—C V I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: '7.e .)5 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -425 Printed: 07 -10 -2008 CRAM' Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -425 Issue Date: 05/29/2008 Permit Expires On: 11/25/2008 Tenant: Name: DAPHNE'S GREEK CAFE Address: 2600 SOUTHCENTER MALL FC -7 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: RYAN WATKINS Phone: 858 - 784 -0811 Address: 6125 CORNERSTONE CT #100 , SAN DIEGO CA Contractor: Name: MERIT ELECTRIC INC Phone: 425 -775 -1356 Address: 19029 36 AV W STE D , LYNNWOOD WA Contractor License No: MERITEI044BQ Expiration Date: 01/18/2010 DESCRIPTION OF WORK: INSTALL NEW ELECTRICAL SYSTEM IN FOOD COURT RESTAURANT IN NEW MALL SPACE Value of Electrical: $15,000.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $410.00 2005 Date: �`2 � { 5? I hereby certify that I have read and xa ;ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of wo I am authorized to sign and obtain this electrical permit. Signature: ° ^ Date: S - 2 - UC Print Name: G+� This permit shall become ull and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -425 Printed: 05-29 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS 2600 SOUTHCENTER MALL TUKW DAPHNE'S GREEK CAFE Permit Number: Status: Applied Date: Issue Date: EL08 -425 ISSUED 04/17/2008 05/29/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: u5f'.[- Dates 2 - U y doc: Cond -Elec EL08 -425 Printed: 05-29 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa. us Electrical Permit No. 9-0 S' Project No. ?Gib �S1 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address:24. 4O Fe— 5:0c.54ce tk M411 Tenant Name: Dc,Onlett S CC I2G Property Owners Name: F. / �n �'s-pr C c, 1.4.c. Mailing Address: 2too F'-7' etrK /M411 King Co Assessor's Tax No.: 1p 3 (C)' 0 ONO Suite Number: 7- Floor:Z L New Tenant: Yes ❑ ..No r-Qkw: 4 City VYA State F(P9� Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name:. y .v. WO.4 /€4k1 $ Mailing Address: C(Z S (,v nAteS ion•. el. 14.1o0 Day Telephone: '& " - dgi 1 5," 15,e9d cA gi2.121 State Zip E -Mail Address: rk,e_1 -k4-5 OD d404fueS • 6;a-- City Fax Number: $s-s-' earzs- ELECTRICAL CONTRACTOR INFORMATION Company Name: T Mailing Address: Zip Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Valuation of Project (contractor's bid price): $ ICJ 0° e Scope of Work (please provide detailed information): 7n Sh %/ /ti4.i else no- vttu. 401 feed.- 4- S( ce. ;A X144#5 Sdd44t e J904,S1 5.; . ssl ✓.?,t .n Will service be altered? )Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ,New ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Property Served by: jzr Puget Sound Energy ❑ Seattle City Light HAApplicaaonsWorms- Apphcanons On Line\4 -2007 - Electrical Permit Application.doc bh 'Tenant Improvement ❑ Temporary Service Page 1 oft RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75 00 ea ❑ Low voltage systems (alarm, furnace thermostat) .................. ... $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Pian Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: z/Z Print Name: 'Zia .L a Mailing Address: (33 e..J .,- M,r T7aft- 5 city Date: 4111 7/° t' Day Telephone: 2. o G — 4a i - Go rt Date Application Accepted: itt state zip Staff Initials: w4 Date Application Expires: I 0- 17 OAS H ''ApplIcat onsVonns- Apphcations On Gne14-2007 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http./Iwww.citukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01804 Initials: WER User ID: 1655 Payee: WESTERN CONSTRUCTION SERVICES INC. Payment Date: 05/27/2008 Total Payment: 3,121.28 SET ID: 0527 SET NAME: DAPHNE'S SET TRANSACTIONS: Set Member Amount D08 -193 1,532.28 EL *0'8'• -5 688.00 08 -108 155.0 PG08 -121 745.90 TOTAL: 3,121.28 TRANSACTION LIST: Type Method Description Amount Payment Check 8832 3,121.28 TOTAL: 3,121.28 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES 000/322.100 1,167.78 ELECTRICAL PERMIT - NONR 000.322.101.00.0 328.00 ELECTRICAL PLAN - NONRES 000.345.832.00.0 360.00 GAS - NONRES 000.322.103.00.0 113.90 MECHANICAL - NONRES 000.322.102.00.0 155.10 PLAN CHECK - NONRES 000/345.830 720.00 PLUMBING - NONRES 000.322.103.00.0 272.00 STATE BUILDING SURCHARGE 000/386.904 4.50 TOTAL: 3,121.28 2874 05/27 9710 TOTAL 3121.28 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.u.s RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -425 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/17/2008 Applicant: DAPHNE'S GREEK CAFE Issue Date: Receipt No.: R08 -01221 Initials: WER User ID: 1655 Payment Amount: $82.00 Payment Date: 04/17/2008 03:19 PM Balance: $328.00 Payee: FILI ENTERPRISES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 38000 82.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 82.00 Total: $82.00 12813 04/17 9711 TOTAL 999.03 Y\t doc: Receipt -06 Printed: 04 -17 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: nmooi Type of Inspection: 2i Address: � �� Date Called: Special Instructions: Date Wanted: / �! ti. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: c1/ 1t Inspector: Jn��q IDate o,0 di? ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY =OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila; WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: po, � r Type of Inspection: �taD Address: Date Called: Special instructions: Date Wanted: �(/47 a r p.m. Requester: Phone No: t<I Approved per applicable codes. Corrections required prior to approval. MENTS: Inspector: 6 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: Receipt No.: !Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 61,9Y- tiz PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: D 5 Type of Inspection: 2-400 Address: -Coo Date Called: Special Instructions: Date Wanted: fi Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: rtchnniti 6 4-anitdr e bukL, of F & f kt Inspector: ($606c, Date: C +to (04 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6ta- Lo-s- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: p 0 tC- 1� /� Type of Inspection: Z R O Address: 74 Do AAte�,, Date Called: — GC -C-1 I4 lip PaP - Pt NOL -tc-5 Dt4 &O»( ciaux Pa'(.L+J'i-- Special Instructions: - /5- A O/( kg Kook Lo (y Sod,, Date Wanted: 1 it o a.m Requester: Phone No: Approved per applicable codes. igiCorrections required prior to approval. COMMENTS: ' - °'r To (ix I6/9) — GC -C-1 I4 lip PaP - Pt NOL -tc-5 Dt4 &O»( ciaux Pa'(.L+J'i-- — u Jt ( wAiX._ I"I CVa^PaQ4 - /5- A O/( kg Kook Lo (y Sod,, ADP rv2i At4e110 mgt r Inspector: 1;01 Date: 07 1(0 /LZ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ft 0 - Project: Ditire f> Type of Inspection: /0°.y Address: ,�,y ` 00 pi / Date Called: , Special Instructions: - Date Wanted: p 7/ ( a Requester: Phone No: 14 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 9.K (6.14\k‘ covEi K6J414. IA) Inspector: 1.16( Date: li O U i ❑ $60.00 REINS ECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 1 ECTION NO. PERMIT NO. CItY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: d' pik„ te, 3. I set 3 Type of Inspection: 7003 Address: 24 00 4 _ _ Date Called: Special Instructions: Date Wanted: 't f .• Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Pa 12K ittAi Klitwey (44-szP I-I Inspector: 6044,c, Date: 41 c ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: a01-42-C INSPECTION NO. r • r INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: p Jr+ v �,� 1, __ Type of Inspection: 3 Address: 200 111414, Date Called: Special Instructions: Date Wanted: G 10 p.m. Requester: Phone No: Approved per applicable codes. Ei Corrections required prior to approval. COMMENTS: D.K . - JPPt& Sir -F�r c.a�5 1164) 6a4-0 Of/ Inspector:��V,Y Date: 047(0/0\c El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: IDate: °,.... e.,.. f` -c. _ ..s.s..e1.._s0 INSPECTION NO. INSPECTION RECORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 PERMIT NO. (206)431 -3670 Project a'� 13 'I' Type of Inspection �� <�l ` Address: n Date Called: Special Instructions: Date Wanted: 6 /g a n Requester: Phone No: roved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Inspe . it 6,;" Date:/_7v r7$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form L -1 2006 Washington State Nonres dentlal Energy Code Compliance Forms Revlsed July 2007 Project Info Project Address Daphne's Greek Cafe' Date 4/1/2008 2600 Southaenter Mall #FC -7 For Building Department Use Tukwila, WA 98188 Applicant Name: Studio C AppllCantAddreSS: 6125 Cornerstone Ct. E. #200 San Diego, CA 92121. Applicant Phone: 858- 866 -0889 W i; COPY l:m a Permit No Pic!' re.t;cs.F approval is cubJe t to errs. a^d clriOr:). r,:r r. n` constructor doc!attar!° ct.n, r,A$ airlh or,: t I ' e hn" i sr! s., is 1�' ;' ELO8 LI 25 RECEIVE[ APR 17 2008 PERMIT CENTEI 6. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Daphne's Greek care' Date 4/1/2008 2600 Southcenter Mali 6FC -7 For Building Department Use Tukwila, WA 98188 Applicant Name: Studio C Applicant Address: 6125 Cornerstone Ct. E. #200 San Diego, CA 92121 Applicant Phone: 858 - 866 -0889 Project Description SERVICE ❑ New Building ❑ Addition a Alteration I Plans Included Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area KITCHEN RESTAURANT 1.30 790.0 1027.0 SERVICE HALOGEN DOWNLIGHT 13 50.0 650.0 HALOGEN WALL WASHER 1 40.0 40.0 " From Table 15-1 (over) - document all exceptions on form LTG-LPA Total Allowed Watts 1027.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed KITCHEN 24 "x48" FLUOR. TROFFER 5 62.0 310.0 SERVICE HALOGEN DOWNLIGHT 13 50.0 650.0 HALOGEN WALL WASHER 1 40.0 40.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1000.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (If included). For track lighting, list the length of the track (in feet) In addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum Input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Fomi Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: Q Warehouses, storage areas or aircraft storage hangers Q Other Qualification Checklist Note: If occupancy type is "Other" and fukture Lighting Fixtures: Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. answer is checked, the number of fixtures in (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector the space is not limited by Code. Clearly 1521) or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T-8 lamps, and d) hard -wired elec- indicate these spaces on plans. If not 1.2 tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified, do SPA Calculations. Cafeterias, fast food establishments'', restaurants/bars5 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts Post office 1.1 3. LED lights. TABLE 15-1 Unit Lighting Power Allowance (LPA Use' LPAR (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (Including but not limited to schools hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations5 1.0 Cafeterias, fast food establishments'', restaurants/bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall3:4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries° 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 ootnotes for t able 15- 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be Increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Ughting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter - height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling - mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable In both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary I LTG -EXT 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info ProJAddres: Daphne' a Greek Cafe' Date 4/1/2006 2600 Southcenter Mall SFC -7 For Building Department Use Tukwila, WA 98188 Name: studio c Appl. Name 6125 Cornerstone Ct. E. 5200 San Diego, CA 92121 AppI. Phone 858 -866 -0889 Project Description ❑ New ❑ Addition ❑ Alteration ❑ Plans Induded Refer to WSEC Section 1513 for controls and commissioning requirements. Compliance Option 0 Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 Iumens/W ❑ Controlled by motion Sensor i♦ Exemption (list) Alteration Exceptions (check appropriate box sec. 1132.3) J No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of Items Allowed Watts x ft2 (or x If) Tradable Proposed Lighting Wattage Total Allowed Watts Use mfgr listed maximum input wattage. For fixtures with hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Total Proposed Watts may not exceed Total Allowed Watts for Exterior Non - Tradable Maximum Allowed Lighting Wattage Total Proposed Watts Non - Tradable Locations Description Allowed Watts per ft2 or per If Area (ft2), perimeter (10 or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Location Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Proposed Watts may not exceed Allowed Watts for Category 2006 Washington State Nonresidential Energy Code Compliance Form Exterior Lighting Summary (back) LTG -EXT 2008 Washington State Nonresidential Energy Code Compliance Forms TABLE 15 -2 LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised July 2007 Tradable Surfaces (Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded.) Uncovered Parking Areas Parking lots and drives 0.15 W /ft& Building Grounds Walkways less than 10 feet wide 1.0 W /linear foot Walkways 10 feet wide or greater plaza areas Special feature areas 0.2W /ft2 Stairways 1.0 W /fig Building Entrances and Exits Main entries 30 W/linear foot of door width Other doors 20 W/linear foot of door width Canopies and Overhangs Canopies (free standing and attached and overhangs) 1.25 W /ft2 Outdoor Sales Open areas (including vehicle sales lots) 0.5 W/& Street frontage for vehicle sales lots in addition to "open area" allowance 20 W/linear foot Non - Tradable Surfaces (Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table.) Building Facades 0.2 Wife for each illuminated wall or surface or 5.0W/linear foot for each illuminated wall or surface length Automated teller machines and night depositories 270 W per location plus 90 W per additional ATM per location Entrances and gatehouse inspection stations at guarded facilities 1.25 W/ft2 of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces") Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/& of uncovered area (covered areas are included in the "Canopies and Overhangs" section of "Tradable Surfaces ") Material handling and associated storage 0.5 W /ft2 Drive -up windows at fast food restaurants 400W per drive- through Parking near 24-hour retail entrances 800 W per main entry 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer. Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Daphnes creek Cargo 'Date 4/1/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E2 yes 1513.2 Area controls Maximum limit per switch E2 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yea 1513.4 Display /exhib /special Indicate separate controls E2 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timer w /backup Indicate location (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location 1513.6.1 (a) occup. sensors Schedule with type and locations yes 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans El 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes 1 1514 'Max. watts 'Indicate watts for each exit sign 1E2 l LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n. a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) n. a. I 1511 'Dec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I 1 ' TRANSFORMERS (Section 1540) n.a. I 1540 'Transformers 'Indicate size and efficiency 1 I If "no" is circled for any question, provide explanation: 2006 Washin ton State Nonresidential Ene • Code Com 'Hance Form • Lighting, Motor, and Transformer Permit Plans Checklist 2008 Washington State Nonresidential Energy Code Compliance Forms LTG -CHK Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.8.1. Where automatic time switches are cited, they shall have the features listed In Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of turning off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole. 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All dayiighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights Independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not Include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer light fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled Independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically tuming off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of tuming off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which tums off all loads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is Interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 ft2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an Input power demand of 5 Watts or less per sign. Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more. which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP -1- 2002). • • PERMIT COOR COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -425 DATE: 04 -17 -08 PROJECT NAME: DAPHNE'S GREEK CAFE SITE ADDRESS: 2600 SOUTHCENTER MALL FC -7 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: t s k 2 -03 B IPng Division Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -22 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -20 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments Issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7A)70 / Plan Check/Permit Number: Q —7 a r ❑ Response to Incomplete Letter # 111 Response to C orrection Letter # f Revision # I after Permit is Issued t-- Revision requested by a City Building Inspector or Plans Examiner Project Name: Z2fi"/' luc- 5 Project Address: a (9 O 5 alis6 Contact Person: "7—"Spfrt. `3V lt/G l/ Phone Number: b2 D 6 -4,245:C.-.,7/,, Summary of Revision: 4Sei) 40 t,t1 v4l.e d c ovvs4Irtr ! w4 (a— 00 RECIERIEll OITV IFTUKWILA JUL 10 2008 Sheet Number(s): "Cloud" or highlight all areas of revision including revisi ` Received at the City of Tukwila Permit Center by: Entered in Permits Plus on �' 1(�—O t \applications\forms- applications on line \revision submittal Created: 8 -13 -2004 Revised: Look Up a Contractor, Electri an or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License MERITEI044BQ Licensee Name MERIT ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 601680785 Ind. Ins. Account Id SECRETARY Business Type CORPORATION Address 1 19029 36TH AVE W STE D Address 2 City LYNNWOOD County SNOHOMISH State WA Zip 98036 Phone 4257751356 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/18/1996 Expiration Date 1/18/2010 Suspend Date Separation Date Parent Company Previous License TRINAI *132KH Next License Associated License LANUMJD978D4 Master Electrician Information License LANUMJD978D4 Name LANUM, JACK D Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date DEFAYE, PHILIPPE MARC PRESIDENT 12/06/2001 WILSON, CHRISTINA SECRETARY 12/06/2001 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= MERITEI044BQ 05/29/2008 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us 6364200010 2600 SOUTHCENTER MALL TUKW DAPHNE'S GREEK CAFE RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -425 ISSUED 04/17/2008 05/29/2008 Receipt No.: R08 -02512 Initials: WER User ID: 1655 Payment Amount: $41.00 Payment Date: 07/10/2008 02:35 PM Balance: $0.00 Payee: TOM BUNCH TRANSACTION LIST: Type Method Descriptio Amount Payment Cash 41.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 32.80 8.20 Total: $41.00 4662 07/10 9711 TOTAL 41.00 doc: Receiot -06 Printed: 07 -10 -2008 } P g ~. mm` 4 TT /~A-m ~� • ON LID ( !/ �j/ 99,7; ;c! ' L Bra .~ . `— ~ . 11,4 TIER I '/ 7847,-'___^-'~ A-T ^7 / I ill fl • II if \rtLidi b ION SEE DESK ELEVA 6/A3 FOR / - OUT SEE NO / EE � Hin / / / / \-._'1- S|<� SOFFIT) VN A-30 ' - -- ' (]� .~.`�/ IN SOFFIT FOR T.V. (TYp. ) / // � 1 [� |�KGN8UNDER8GEPARATE9ERk4[T&APPRO\AL | =LA 3/16"711-0 U `—`--`` • `~' ..~ ■ -'--~..� • A-38,40,42 3/4"C.-3#12 3/4^.J3#12 CO • ' 3/4^C/ � �' �^� / .�u* ‘/\,/ // / / '� ' / ' // ~�,-_ ° / / / \ // . \ --!=`=-,:=:_.,'; ! / ',\ �� = ELECT'LINTERLOCK REQUIRED FOR: ^ ~�. 460 Mechanical Fl Electrical NeaPlumbing 7_V, Gas Piping '_ DIVISION NOTES: 1, ELECTRICAL SUBJECT TO NSPECTONS. 2. ALL SIGNS REQUIRE SEPARATE PERMITS AND APPROVALS 3. ALL EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNZED TESTING LABORATORY. 4. ALL ELECTRiCAL EOUIPMENT EXPOSED TO WEATHER SHALL E LISTED FOR EXTERIOR USE, 5. CONTRACTOR SHALL USE A CODE APPROVED WIRING METHOD OF THE FOLLOWING: a) ALL CONDUITS BELOW SLAB OR GRADE SHALL BE PVC AND SHALL INCLUDE A GROUND WIRE b) ALL EXPOSED CONDUIT SHALL BE EMT c) ALL CONDUCTORS FOR FEEDERS AND BRANCH WIRING SHALL BE COPPER d) CONCEALED BRANCH WIRING MAY BE TYPE MC OR AC CABLE. !F APPROVED FOR USE BY THS JURISDICTION. 6. ALL ELECTRICAL PENETRATIONS fNTO THE WALK-IN COOLER SHALL BE SEALED PER SECTION 300-7OF THE NEC. 7. PROVJDE SEPARATE CONTACTOR FOR CHEF BASE TO ALLOW CHEF BASE POWER TO REMAN ON WHEN OTHER EQU/PMENT UNDER HOOD IS SW!TCHED OFF W/ HOOD - CHEF BASE POWER SWITCHED OFF ONLY BY HOOD ANSUL SYSTEM IN CASE OF F!RE. fL ALL VISIBLE OUTLET & SWITCH COVERPLATE8 IN DINING AREA SHALL BE STAINLESS STEEL 9. ELECTRICAL CONTRACTOR SHALL PROVIDE & INSTALL ALL MATERJALS NECESSARY TO INTERLOCK THE MAKE-UP AIR FAN, EXHAUST HOOD & OUTLETS AT COOKLINE WITH THE ANSUL SYSTEM N ORDER TO PROVIDE EMERGENCY EQUIPMENT SI-IUT DOWN AS REQUIRED BY THE RRE DEPARTMENT. 10. WHEN SJGNAGE CRCUITS ARE CONNECTED TO TENANT (DAPHNES) PANEL. USE TORK MODEL #1 103 TIME CLOCK FOR SIGNAGE CIRCUITS - SET TO POWER ON AT DUSK & OFF ATMIDNIGHT 11. ALL 125V ELECTRICAL RECEPTACLES LOCATED IN THE KITCHEN AREAS SHALL HAVE GROUND FAULT CIRCUIT INTERRUPT!ON PROTECTION PER NEC 21OE8(B)(2) 12. CONDUCTORS SHALL BE COPPER RATED AT NOT LESS THAN 600 VOLTS. MINIMUM WIRE SIZE SHALL BE#12AVVGi1C\N. ALLWIRE #B AWG AND LARGER SHALL E STANDED, #1O THRU #12 AWG CONDUCTORS SHALL BE SOLID. USE THE 75C AMPACITY RATING FOR CONDUCTORS FEEDING EQUIPMENT RATED 100A OR LESS OR FOR EQUIPMENT RATED FOR CONDUCTORS #1 AWG OR LESS. 13. ALL CIRCUIT DREAKERS CONTROLUNG FLUORESCENT LIGHTNG SHALL SWD LISTED. 14.PROV|DE ENGRAVED PHENOLIC NAMEPLATES FOR ALL PANELBOA DS & DISCONNECT SWITCHES, WHITE LETTERS ON BLACK BACKGROUNID. EL. ±14'41"AF ' (E) ROOF JOISTS 6, EL. 11'41AF 2x4 CLG. GRID � 2x4 CLG. GRID FILE COPY Permft No. KEY NOTES: 1 [F� | 2 ( 4 1_5] ' MIIWIMII•MMWMION SECTION VIEW TENANT PANELS (PROVIDED & INSTALLED BY G.C. - CONNECT TO(E) MAIN BREAKER & METER /N SVVTCHGEAR' SEE SINGLE LINE DIAGRAM) LIGHTING CONTROLLER ON WALL © 7 T A.FF SEE DIAGRAM - SHEET E2 (E) 1"C. T0N1.9.C\E. ABOVE CEILING V0 PULL8TR|NG(TELEPHONE)-0.F J-BOX FOR CAT. 5 CABLE & TELE. HOME RUN TO MGR. DESK 75KVA STEP-DOWN TRANSFORMER ABOVE SEE DTL. #3 (E) STL. WIDE FLANGE 9URLN��±��~O�. — UNISTRUT P1000 CHANNEL V0P13B0 BEAM CLAMPS -SPAN BETWEEN (2) PURLINS STEP-DOWN 01/2" THREADED ROD (TYP. 4 CORNERS) EXTEND CEILING TILES VERT TO UPPER CEILING GRID ELEVATION Plar review approval is subject to ermrs and Approval of construction documents does not authoriz' e the violation of any adopted code or ordinance. Receipt of approved Field Copy and ons is acknowledged: ~-~.e.� '. City� w,x � ~�"�� Tukwila BUILDING ��U$�U%�U���� w�x�o«�o��v� _---_ -_- REVISIONS ��M� ��DOhan�esSnan oe"�ave^"^.' � ~ of work without priOr approval Cf Tukwila Building Division NOTE: Revisions will require a new plen submittal ' ��� nk�n[n?n�� ` �d�n8Vinclude 8ddkK�D@|���__�__ "�� 3/4"&--r-0" 1 FRONT VIEW PLAN ��U����� �-�.��U�N ��K���� BRACED CONNECTIONS @ WAL SEE PLAN VIEW PARTITION WALL PER PLAN 5/8rp.R.PLyO.|N LIEU OF GYP. BD_ @ ATTACHMENT TO WALL UN|'8TRUTp-1OOU CHANNEL n1D"LON(3 (yERT')WV(2)3/8"Dx11D" LAG SCREWS INTO BLK,G.V0TR|NWALL VNI-STRUTA1026BRACKET EA. BRACE CONN. TO WALL (4)01/2" THREADED SUPPORT ROD EA. CORNER TO ROOF STRUCT. (4) UNISTRUT P1000 1 5/8" CHANNEL 3/4" FIRE RETARDANT PLYWOOD DECK UNISTRUT P1036 PLATES (TYP. EA. CONNECTION) trt��� / n�n� ELo8 DATE: 03/26/08 JOB NO 28--- DRAWN; CHECKED: C �D A T� | 8 N O �� 0 &` N� �, - - - _ A R C H I T E C T _ 711 N. FIELDER RD, ARLINGTON. TX 76012 PH: C8171 635_5696 FAX: /8171 835-5699 DAPHNE'S GREEK MALL #FC -7 2600 SOUTHCENTER WA 98188 REVISIONS � u�x�����xVu~" APR 1 7 2008 PERMIT td SHEET NUMBER El ELECTRICAL LEGEND ' WALL SWITCH *r»r.Ruom � D ~ O|MKAERVVALLBVV|TCH 4�A��uom LUTRON-ARIADNI #AY-600P-WH O DUPLEX RECEPTACLE 18'xr.ruuN. 6k `� {�FC| DUPLEX RECEPTACLE 18"»�F,uum �� " QUADRUPLEX RECEPTACLE 18-*rFuuN (� DUPLEX MONUMENT pLoonMOwmso 0 ELECTRON\CT-STAT J� "` 240V RECEPTACLE 18''^r.r.u.om 0 JUNCTION BOX V TELEPHONE/DATA OUTLET ou'�,u PULL STRING ABOVE CEILING 18' A.F.r,uow. ELECTRICAL DISCONNECT SCUARE-D , GENERAL ELECTRIC OR CUTLER HAMMER | i / / KEY NOTES: 1 [F� | 2 ( 4 1_5] ' MIIWIMII•MMWMION SECTION VIEW TENANT PANELS (PROVIDED & INSTALLED BY G.C. - CONNECT TO(E) MAIN BREAKER & METER /N SVVTCHGEAR' SEE SINGLE LINE DIAGRAM) LIGHTING CONTROLLER ON WALL © 7 T A.FF SEE DIAGRAM - SHEET E2 (E) 1"C. T0N1.9.C\E. ABOVE CEILING V0 PULL8TR|NG(TELEPHONE)-0.F J-BOX FOR CAT. 5 CABLE & TELE. HOME RUN TO MGR. DESK 75KVA STEP-DOWN TRANSFORMER ABOVE SEE DTL. #3 (E) STL. WIDE FLANGE 9URLN��±��~O�. — UNISTRUT P1000 CHANNEL V0P13B0 BEAM CLAMPS -SPAN BETWEEN (2) PURLINS STEP-DOWN 01/2" THREADED ROD (TYP. 4 CORNERS) EXTEND CEILING TILES VERT TO UPPER CEILING GRID ELEVATION Plar review approval is subject to ermrs and Approval of construction documents does not authoriz' e the violation of any adopted code or ordinance. Receipt of approved Field Copy and ons is acknowledged: ~-~.e.� '. City� w,x � ~�"�� Tukwila BUILDING ��U$�U%�U���� w�x�o«�o��v� _---_ -_- REVISIONS ��M� ��DOhan�esSnan oe"�ave^"^.' � ~ of work without priOr approval Cf Tukwila Building Division NOTE: Revisions will require a new plen submittal ' ��� nk�n[n?n�� ` �d�n8Vinclude 8ddkK�D@|���__�__ "�� 3/4"&--r-0" 1 FRONT VIEW PLAN ��U����� �-�.��U�N ��K���� BRACED CONNECTIONS @ WAL SEE PLAN VIEW PARTITION WALL PER PLAN 5/8rp.R.PLyO.|N LIEU OF GYP. BD_ @ ATTACHMENT TO WALL UN|'8TRUTp-1OOU CHANNEL n1D"LON(3 (yERT')WV(2)3/8"Dx11D" LAG SCREWS INTO BLK,G.V0TR|NWALL VNI-STRUTA1026BRACKET EA. BRACE CONN. TO WALL (4)01/2" THREADED SUPPORT ROD EA. CORNER TO ROOF STRUCT. (4) UNISTRUT P1000 1 5/8" CHANNEL 3/4" FIRE RETARDANT PLYWOOD DECK UNISTRUT P1036 PLATES (TYP. EA. CONNECTION) trt��� / n�n� ELo8 DATE: 03/26/08 JOB NO 28--- DRAWN; CHECKED: C �D A T� | 8 N O �� 0 &` N� �, - - - _ A R C H I T E C T _ 711 N. FIELDER RD, ARLINGTON. TX 76012 PH: C8171 635_5696 FAX: /8171 835-5699 DAPHNE'S GREEK MALL #FC -7 2600 SOUTHCENTER WA 98188 REVISIONS � u�x�����xVu~" APR 1 7 2008 PERMIT td SHEET NUMBER El 4 - 200 WATT CLEAR INCANDESCENT BULBS (EXHAUST HOOD LIGHTS) HOOD SWITCH TO HAVE RED ILLUM.TOGGLE r LIGHTING CONTROLLER OVERRIDE SWITCH 7 ............ „ ,,,,, I I ! ,,,,,,, „... • 014 Mem kyki 11 4Nwb 6V41k 0 CfAA-a, 11146)Amt .fevoilvillidive, iithh % IlAtit,om4 VoAl ok kikt / LOCATION: KITCHEN TYPE PANEL SCHEDULE „A„ DESCRIPTION A i 20V/208V,3PH.,4W. MOUNT: FLUSH 200 AMP 1 MAIN LUG DESCRIPTION LIGHTING-KITCHEN LIGHTING - SOFFIT LIGHTING - SERVICE AREA EXHAUST HOOD VISI-COOLER &LS. / CONV. RECEPTACLE A 310 800 - 1560 B i - -- 4 360 480 C 1 350 380 1 BKR I f i 20 • ; . 20 1 20 ! 20 20 I 20 20 1 CIR 1 i f 1 ' ' 3 [ 410 5 - 1 ' 6 7 1 9 I I I . ; 4 11 , 13 i Fr C1R 2 I ' I 6 '_, 8 10 , : 12 , 141 BKR 20 ., 20 j 20 20 20 20 A 25 .,.._, .1_800 400 B • 1548 I L I. 600 771 DESCRIPTION EXIT SIGNSTEM P.O.S. ..1 LIGHTS ---- RECEPTACLES MANAGER DESK RECEPTACLES ; MANAGER DESK RECEPTACLES I- F-T CE COOKER REF. CHEF BASE ICE MAcHINE 20 1150 LAMP: GE #50PAR30/HIPJFL35 7 CONVECTION OVEN SPARE KITCHEN RECEPTACLE 1000 . - • I I — 400 20 20 15 • ; 16 , 20 -- -6- . ;- 17 I I i 18 I_ 20 720 ' 1 1380 GYRO MACHINES ' REF. PREP TABLE I— DISHWASHER REACH-IN FREEZER FAN COIL - WALK-IN COOLER REMOTE CONDENSER - (RC-1) EXHAUST FAN - (EF-1) ROOF RECEPTACLE 1495 20 20 ,/ • - .-- 2 _ 20 /1 . ' 2 120/ I / 2 ' 20 I 41- 19 ' • 20 ¶20 21 22 23 1 i ' 24 1 ' 4 25 ; 26 27 T i ! 28 I 29 • ' 30 i 31 1 ! 32 • ,, ' 2 20 20 20 20 I 20 365 1440 1000 865 600 BEST LIGHTING #CEX-U-1-G-W (5 WATTS) 840 1800 HOT FooD VVELLs I-- 432 800 7 1144 -- — 1- I 1560 I --I , 1144 1560 - 200 FRYER FOOD HOLDING STATION .. . . .. ..._ . .. . SODA DISP. I CARBONATOR • t SIGNAGE .... EM LIGHT "BUGEYE" W/ WHITE HOUSING 800 I . 33 ! i ' 34 I - -- ; — . 35 ' ' 36 ; _ - ... _, _ -- : SPACE SPACE SPARE ____ . . _ _ d MAKE-UP AIR FAN - (MA-1) WATTS PER LINE 1000 .- 1373 -.- 1 20 • 20 .. 1,,,,-/. ! _1_ ' 37 I I ; 38 '-' —0— ' 1 ' 39 ' 40 2 L-4-1 i -1.---.I, 42.— , I 20 / 3 , 1585 L ,- 1585 -- : , AC-1 H. 6397 6717 1373 5407 r-- 6465 6118 1 1585 6976 12862 TOTAL OA WATTS AT WATTS AT OB 120/208 V V.,10, 12835 A. A. �c 12383 TOTAL LOAD 38.080 30 4W.= 106 , . 12,862 HIGH PHASE 120 107 2W.= ,,, (E) 800A BUS 277/480V, 30,4W - 25K AIC ! • -1 e / /1 11 / i LOW VOIiT .GE ACCEN GHTING IN SOF IT"- VERIFY VV/ OW 1 IGH I ING =1 A 3116"1' -0" INCOMING FROM UTILITY. 00. ,/"NN (E) 800AF (E) 800AT CONT. BUS - 1 GND. 200AF 200AF 200AF 200AF 200AF 2 j, 200AF 200AFfl 100AP TENANT METERS NOTE: SINGLE LINE DIAGRAM SHOWN FOR REFERENCE ONLY - ALL EQUIPMENT, FEEDERS, ETC. ARE EXISTING UNLESS OTHERWISE NOTED SINGLE LINE KEYNOTES: EXISTING 200A, 30, 600V RATED METER SOCKET; METER PROVIDED BY E.C. EXISTING 200A, 30 FRAME, CLASS T FUSE PULL-OUT; VERIFY IN FIELD Ei 4 5 6 NEW 75KVA TRANSFORMER - BY E.C. 480V-208V/120, 30, 4W, Z=5% (90A PRIMARY) (208A SECONDARY) 2"C-4#3/0 1#6 THWN CU. 2"C-44#310 ± 1#6 THWN CU. 200A, 30 FUSED DISCONNECT p 6— H _J_ #6 cu. GND. COLD WATER 200A M.C.B. M.C.B. 1 20.12M1 PANEL "A" (38KVA) LIGHT FIXTURE SCHEDULE TYPE SYMBOL DESCRIPTION A 2C4(;x048" RECESSED 3 LAMP FLOUR. TROFFER: PER #2GR8-332A-UNV-EB81-U LAMPS; GE #F32T8/SP41/ECO - iiiih_rigimi jillw-1111111111b-111111111- NL: NIGHT LIGHT - 1 LAMP ALWAYS ON; NOT SWITCHED B 0 4" LOW VOLTAGE WI ADJUSTABLE DROP TRIM: LITON #LH1499-LR1467W LAMP: GE #037MR16/HIR/CG/FL40 C e 5" RECESSED HALOGEN DOWNLIGHT: LITON #LH-5/LR503NN W/ NATURAL ALUM. RIBBED TRIM LAMP: GE #50PAR30/HIPJFL35 NL = NIGHT LIGHT - ALWAYS ON; NOT SWITCHED SS = COVERGUARD LAMP; NO LENSE V67 LED EXIT SIGN W/ VVHITE HOUSING & EM LITON: LX900G (5 WATTS) (90 MIN. EM BATTERY BACK-UP POWER SUPPLY) LED EXIT SIGN/EM "BUGEYE" COMBO WI WHITE HOUSING BEST LIGHTING #CEX-U-1-G-W (5 WATTS) (90 MIN. EM BATTERY BACK-UP POWER SUPPLY) 46) EM LIGHT "BUGEYE" W/ WHITE HOUSING BEST LIGHTING #R5-I-10-WH-9W REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC APR 2a53 B ILDING DIVISION 1/15t b 1/6 Vtail Its viD 1444 di tkai/D ete- a444 01 Lk eitc 61.0(44o? awfrost e Axel 1.50.* ,T-tiv. 3/o mit-. HON — 120V — TO PANEL (CR TO LIGHTING LOAD KEY NOTES CONNECT TO NEAREST 120V BRANCH CIRCUIT (FIELD VERIFY) 2HR OVERRIDE SWITCH WITH SPRING WOUND (VERIFY LOCAT(ON) 365 DAY PROGRAMMABLE TIME CLOCK WITH WEEKEND & HOUDAY SHUT-OFF FEATURE WHICH TURNS OFF ALL LOADS FOR AT LEASE 24 HOURS THEN RESUMES NORMAL SCHEDULED OPERATION & 10 HOUR MIN. PROGRAM BACK-UP IF POWER IS INTERRUPTED. 0 MULTI-POLE LIGHTING RELAY WITH N.O. CONTACTS AND 120V CONTROL COIL (AS NOTED ON PANEL SCHEDULES (VERIFY # OF POLES) LIGHTING CONTROL DIAGRAM DATE: 03/26/08 JOB NO: 28--- DRAWN: CHECKED: IN11111111•1111111111111111111111■1111 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635-5696 FAX: (817) 635-5699 N „-, 0 t LL 0 0 2600 SOUTHCENTER TUKWILA, WA 98188 REVISIONS 1111M11111■1111111MMIIIIIMIIII RECEW APR 1 7 2008 PERMIT CENTE1 SHEET NUMBER E2