Loading...
HomeMy WebLinkAboutPermit EL08-0428 - WESTFIELD SOUTHCENTER MALL - SUBWAYSUBWAY 2600 SOUTHCENTER MALL FC -6 ELO8-428 City"if Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -428 Issue Date: 07/01/2008 Permit Expires On: 12/28/2008 Tenant: Name: SUBWAY Address: 2600 SOUTHCENTER MALL FC -6 , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 - 713 -4076 Address: 1725 WESTLAKE AVE N SUITE 210 , SEATTLE WA Contractor: Name: CEDAR GROVE ELECTRIC INC Phone: 253 -373 -0056 Address: 1819 CENTRAL AVE S SP 71 , KENT WA Contractor License No: CEDARGE955BC Expiration Date: 01/21/2009 DESCRIPTION OF WORK: NEW PANEL, SERVICE FOR FOOD COURT RESTAURANT TENANT IMPROVEMENT Value of Electrical: $28,000.00 Fees Collected: $676.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: '7— I --O I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this ermit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th erformance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: L/f&'Sc51 -1 Date: — ( This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -428 Printed: 07 -01 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2600 SOUTHCENTER MALL TUKW Suite No: Tenant: SUBWAY Permit Number: EL08 -428 Status: ISSUED Applied Date: 04/18/2008 Issue Date: 07/01/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: jr 34 Date: 7- r - o� doc: Cond -Elec EL08 -428 Printed: 07 -01 -2008 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. e LO 8- )-8 9ovoe»7 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address:V V Tenant Name: Property Owners Name: Mailing Address: ca4 King Co Assessor's Tax No.: AG94 'kT Oo(O `Suite Number: Floor: /^ New Tenant: ...Yes El.. No ketteritIMILA Cory State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Day Telephoone:_i4910o' C�_/ Mailing Address: / 1i�v 1 t e 1�� (Sl! f 7,w es ��,e r." l0 vhf V%LL 1 Y)K/ YI"lL Fa 7% "Jtat(L O7(JO l E -Mail Address: � � - i'V� Fax Number: ELECTRICAL CONTRACTOR INFORMATION Company Name: 773 Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of ork (please provide detailed info : tion): 7/V yVU/ 7 11E( Vvvt Will service be altered? Type of Use: Type of work: 4.1■Iew ❑ Addition ❑ Service Change ❑ Remodel ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication Yes ❑ No Adding more than 50 amps? Yes ❑ No Pro e Served b : uget Sound Energy ❑ Seattle City Light H:Applicanons•.Forms- Applications On Line 4 -2007 - Eleemeal Permit Appheanon dire bh ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages. pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ca RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits 510.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees arc based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Camivals $75.00 Number of concessions $10.00 ca PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Date: •mg- Day T lephone: 1� City State Zip Cal Date Application Accepted: K.- A Date Application Expires: (M ,,t Staff Initials: ( A J(,,,/� I1 Applicanons Fotmt- Applications On I tne'4 -2007 - Electncal Permit Appltcation.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -428 Address: 2600 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/18/2008 Applicant: SUBWAY Issue Date: Receipt No.: R08 -02349 Initials: WER User ID: 1655 Payment Amount: $541.20 Payment Date: 07 /01/2008 10:02 AM Balance: $0.00 Payee: J T BATTERSON TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3057 541.20 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 541.20 Total: $541.20 4296 07/01 0711 TOTAL 541.20 doc: Receiot -06 Printed: 07 -01 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/lwww.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -428 Address: 2600 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/18/2008 Applicant: SUBWAY Issue Date: Receipt No.: R08 -01240 Initials: WER User ID: 1655 Payment Amount: $135.30 Payment Date: 04/18/2008 03:30 PM Balance: $541.20 Payee: JIMMY ENTERPRISES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3798 135.30 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 135.30 Total: $135.30 doc: Receiot -06 Printed: 04 -18 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: erw Type of Inspection: Address: 24 co � e� {'j Date Called: Special Instructions: Date Wanted: 90� - Requester: Phone No: �-1 Approved per applicable codes. D Corrections required prior to approval. COMMENTS: 0 Inspector: Date: 07/0z14 D$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit kOg- yz's PERMIT NO. CITY OF TUKWILA BUILDING DIVISION it- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: � r� %)() Type of Inspection: 70°5 Address: ;.(,, V lc* Date �alled: Special Instructions: Date Wanted: Vi a.m. p.m. Requester: Phone No: Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: Ltluf\l‘ �qJ� n% Inspector: 'Date: o` 2.4 a3,$ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ?- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ettg- ' j2 Project: ,� � .- +� fM Type of Inspection: 7IJ(J� IJCJ Address: ?-(eoo Date Called: r-. Special Instructions: Date Wanted: 1 ' 1-1 ' a.m. .m. "Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: .11 Inspector: s0 Date: ink f't* n$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: R9d176Sboal i r6P�Ng eOs° "" &a°- zaa.t• ,. v INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: / VUW� Type of Inspection: 1003 Address: 2400 litt, Date Called: Special Instructions: Date Wanted: 7 P 11 a m p.m. Requester: Phone No: Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: • fre.�-r� PaTlec. 1-re r -LO( Co.JD4( rS vJro 4�6c. T1(4 Sfer 5a2aKi Lcjcc,CPf a iDoP� Inspector: Date: 07 ! I (fo ' El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary 2006 Washington State Nonresidential Energy Code Compliance Forms PRJ -SUM Revised July 2007 Project Info Project Address 2600 -FC6 Southcenter Mall Date 3/27/2008 Tukwila, WA 98188 For Building Department Use Applicant Name: Keith Smith Applicant Address: 1725 westlake Ave. es, suite 210 Applicant Phone: Seattle, WA 98109 ELOS tizg REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC APR 2 2 2008 11 /1 'Pi Of Tukwila B ILDIN DM ION RECE VE1 AR 18 2008 PERMIT CENTEF, 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 2600 -FC6 Southcentar Nali Date 3/27/2008 Tukwila, WA 98188 For Building Department Use 107 Applicant Name: Keith smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 Project Description 102 ❑ New Building ❑ Addition ✓ Alteration ✓ Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2*" Area in ft2 Allowed x Area 107 PREP AREA 1.30 237.0 308.1 102 BACKBAR AREA 1.30 473.0 614.9 "" From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 923.0 Provosed Li htine Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 102 1,1 - CANOPY MTD. 2X2 FLUORESCENT 7 64.0 448.0 107 12 - RECESSED FLUORESCENT 17 18.0 306.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 754.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (hack) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. BLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5•'•" 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food estabiishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail", retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ', storage areas 0.5 Hotel banquet/conference/exhibition hall3' 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries'' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Aiijustnients LTG -LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 12600 -FC6 southceater Ma11 'Date 3/27/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for in erior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior Location Y (floor /room no.) ., Occupancy Description Allowed Watts per ft2 " Ceiling Height for this room Ceiling Height limit for this exception** Adjusted LPA Watts per ft2 102 HACIRAR AREA 1.30 12.0 feet 12 feet 1.30 107 PREY AREA 1.30 12.0 feet 12 feet 1.30 ** From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 2600 -FC6 Southcenter Mall 'Date 3/27/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control /access Schedule with type, indicate locations E -1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w/backup Indicate location E -1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yea 1513.6.1 (a) occup. sensors Schedule with type and locations E -1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 'Max. watts 'Indicate watts for each exit sign 1 131 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 'Elec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency IM_2 1 TRANSFORMERS (Section 1540) yea I 1540 'Transformers 'Indicate size and efficiency IE -2 1 If "no" is circled for any question, provide explanation: • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -428 DATE: 04 -17 -08 PROJECT NAME: SUBWAY SITE ADDRESS: 2600 SOUTHCENTER MALL FC -6 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: S1.1(/ 4247r2 Bui I g umsion Fire Prevention ❑ Planning Division Public Works ❑ Structural ❑ Permit Coordinator 1v DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -22 -08 Complete Fv/ Incomplete Not Applicable I I Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required E DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -20 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 Look Up a Contractor, Electrician or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License CEDARGE955BC Licensee Name CEDAR GROVE ELECTRIC INC Licensee Type ELECTRICAL CONTRACTOR UBI 602254353 Ind. Ins. Account Id 948801 Business Type CORPORATION Address 1 1819 CENTRAL AVE S SP 71 Address 2 City KENT County KING State WA Zip 98032 Phone 2533730056 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/21/2005 Expiration Date 1/21/2009 Suspend Date Separation Date Parent Company Previous License CEDARGE995DW Next License Associated License BATTEJT967C5 Master Electrician Information License BATTEJT967C5 Name BATTERSON, J T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BATTERSON, J T AGENT 01/03/2005 BATTERSON, J T PRESIDENT 01/03/2005 (Bond Information 1 Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= CEDARGE955BC 07/01/2008 ELECTRICAL SYMBOL LIST SYMBOL DESCRIPTION MANUFACTURER 25(2' RECESSED FUORESCENT LIGHTING FIXTURE VOLTAGE 2'x2' RECESSED FUORESCENT NIGHTLIGHT KVA CONN. 0 RECESSED FLUORESCENT DOWNLIGHT WITH LENSE SODA MACHINE 4' -0" FLUORESCENT STRIP WITH LENSE 1 120V -10 BATTERY POWERED EMERGENCY LIGHT 1.2 5-20R ® EXIT LIGHT WITH BATTERY BACK -UP $ SINGLE POLE SWITCH 17-/) 15A, 120V DUPLEX RECEPTACLE e 208V SPECIAL OUTLET 5 -15R JUNCTION BOX J FRONT COUNTER DUKE FUSED DISCONNECT SWITCH EH NON FUSED DISCONNECT SWITCH GFI GROUND FAULT INTERRUPTING IG ISOLATED GROUND v TELEPHONE/DATA OUTLET KITCHEN EQUIPMENT SCHEDULE NO. ITEM MANUFACTURER QTY VOLTAGE AMPS KVA CONN. REMARCKS 9 SODA MACHINE CORNELIUS 1 120V -10 10.0 1.2 5-20R 2 #12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 15 DISPLAY REFRIGERATOR TRUE 1 120V -10 8.6 1.1 5 -15R 2 #12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 19 FRONT COUNTER DUKE 2 120V -10 8,5 1.1 5 -20R 2 #12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 24 SUBSHOP 2000 P.O.S. MICROS SYSTEMS, DELL, SUBTOTAL 1 120V -10 5.0 .6 5- 20RI.G. 2 #12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 25 MICROWAVE AMANA/SHARP 1 120V -10 10.0 1.2 5 -20R 2#12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 27 BREAD OVEN DUKE 1 208V -30 19.2 6.7 DIRECT 4#10 & 1 #10GRD -3/4 "C TO 30A -3P CKT. BRKR. 29 MENUBOARD TRANSLITE SONOMA 2 120V -10 1.0 .12 5 -20R 2 #12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 33 REFRIGERATED BACK COUNTER DUKE 1 120V -10 6.4 .77 5 -15R 2#12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 34 RAPID COOK OVEN TURBOCHEF 1 120V -10 GENERAL OUTLETS 6.3 6 -30R 2#10 & 1 #10GRD -3/4 "C TO 30A -2P CKT. BRKR. 35 ICE MACHINE ICE -O -MATIC 1 120V -10 13.0 1.6 DIRECT 2 #12 & 1 #12GRD -1/2 "C TO 20A -1 P CKT. BRKR. 38 HOT WATER TANK RHEEM 1 208V -30 50.0 18.0 DIRECT 3#4 & 1#8GRD TO 70A -3P CKT. BRKR. 47 REFRIGERATOR NORLAKE 1 208V -10 12.0 1.4 DIRECT 2 #12 & 1 #12GRD-1 /2" TO 20A -2P CKT. BRKR. 48 FREEZER NORLAKE 1 208V -10 12.0 1.4 DIRECT 2#12 & 1 #12GRD -1/2" TO 20A -2P CKT. BRKR. 50 SODA STORAGE COKE 1 120V -10 10.0 1.2 5-20R 2#12 & 1 #12GRD -1/2" TO 20A -1 P CKT. BRKR. NEW TENANT (SUBWAY) SEE PANEL SCHEDULE EP -A 3#6 & 1 #10G RD -3/4 "C CONNECT TO SPARE 60A -3P -` _L EXISTING DISTRIBUTION PANEL 480/277V -30-4W J r TENANT J METERING T f200A -3P 150A FUSE zJ FIRST LEVEL 4#1/0 & 1#6GRD -2 "C LOWER #6GRD BOND TO BLDG STEEL - LOWER LEVEL ELECTRICAL ROOM NEW 45KVA TRANSFORMER 480V- 120/208V, 30, 4W PARTIAL ELECTRICAL RISER DIAGRAM NO SCALE LEDGEND - - - - DASHED LINES INDATE EXISTING ELECTRICAL EQUIPMENT SOLID LINES INDATE NEW ELECTRICAL EQUIPMENT LEVEL 29 33 35 50 ELECTRIC PANEL No. "A" VOLTAGE: 120/208 PHASE: 3 WIRE: 4 MAIN BRKR SIZE: 150A MTG: FLUSH EAT No. sI LOAD VA No rE LOAD VA 1 20/1 FLUOR. LTG - BACK 500 2 20/1 SODA MACHINE 1200 3 20/1 FLUOR. LTG - FRONT 1000 4 15/1 DISPLAY REFRIG. 1030 5 20/1 DOWNLIGHTS - FRONT 850 6 20/1 FRONT COUNTER 1020 7 20/1 MENU - BOARDS 300 8 20/1 FRONT COUNTER 1020 9 15/1 REFRIG. BACK COUNTER 750 10 20/1 P.O.S. 500 11 20/1 ICE MACHINE ` 1560 12 20/1 MICROWAVE 1200 13 20/1 SODA STORAGE 1200 14 20/1 GENERAL OUTLETS 800 15 20/1 GENERAL OUTLETS 800 16 20/1 GENERAL OUTLETS 500 17 20/1 SPARE - 18 20 REFRIGERATOR 1250 19 20/1 SPARE - 20 2 1250 21 30 RAPID COOK 3000 22 20 FREEZER 1250 23 2 OVEN 3000 24 2 1250 25 3D 2217 26 70 18 KW 6000 27 BREAD OVEN 2217 28 HOT WATER 6000 29 3 2217 30 3 HEATER 6000 31 - SPACE - 32 - SPACE - 33 - SPACE - 34 - SPACE - 35 - SPACE - 36 - SPACE - 37 - SPACE - 38 - SPACE - 39 - SPACE - 40 - SPACE - 41 - SPACE - 42 - SPACE - INTERRUPTING RATING SHALL AMPERE CURRENT FOR THIS ASSEMBLY BE 10,000 A. RMS SYM. TOTAL CONN. 49.9 TOTAL DEMAND 39.5 TOTAL DEMAND 109.7 KVA KVA AMPS GENERAL ELECTRICAL NOTES 1. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2. COORDINATE ELECTRICAL WORK WITH OTHER TRADES AS REQUIRED. 3. ALL WORK MUST BE COMPLETED TO THE LATEST APPLICABLE CODES. 4. EXIT, EMERGENCY AND NIGHTLIGHTING SHALL BE CONNECTED TO LOCAL AREA LIGHTING CIRCUIT, AHEAD OF SWITCH. 5. PRIOR TO INSTALLATION DO A PRELIMINARY LAYOUT OF ALL RECEPTACLES AND LIGHT FIXTURES FOR ARCHITECT AND OWNER REVIEW AND APPROVAL. 6. ALL SURFACE MOUNTED ELECTRICAL FIXTURES TO HAVE 4" ROUND ELECTRICAL BOX. 7. LIGHT FIXTURE SPECIFICATIONS AND SELECTIONS BY OWNER/CONTRACTOR. 8. OWNER/CONTRACTOR IS RESPONSIBLE QUALITY, DETAILS, COORDINATION AND ASSURING THAT ALL ELECTRICAL FIXTURES AND SYSTEMS MEET CODE, ARE SAFE AND CONFORM TO THE ARCHITECTURAL INTENT OF THESE DOCUMENTS. 9. PROVIDE ADDITIONAL FIRE ALARM EQUIPMENT AS REQUIRED. COORDINATE INSTALLATION WITH BUILDING OWNERS FIRE ALARM CONTRACTOR. 15 19 19 24 25 J.B. FOR UPPER SIGNAGE J.B. FOR LOWER SIGNAGE 36" HIGH BUILT COUNTER WITH S.S. TOP ABO • -1 A -3 36" HIGH BUILT COUNTER WITH 5.5. TOP +fi `9 .. •:• ,4\ . ' { r 100A - 3P A -26, 28, 30 ELECTRICAL PANEL -A LIGHTING PLAN SCALE : 1/4" = 1' -0" NOTES 1_ EXIT, EMERGENCY AND NIGHT LIGHTING SHALL CONNECTED TO A LOCAL AREA LIGHTING CIRCUIT - AHEAD OF SWITCH. 2. FINAL SELECTION AND APPROVAL OF LIGHTING FIXTURES SHALL BE BY OWNER AND ARCHITECT. R, ' /'' .r{ � ..� %' g5 {' \`':.. { .t.\ 36 .$ I.G. A -20 • • 'Q142 f./ 1 � � f .: 14°�tGFI .dam • �.'•_ . f f -r A.9 A \ - 4 2 ,.: r, 41 6EPARATE PERMIT ':. REQUIRED FON WMeChantcal a Electrical lumbin9 i Gas Piping city oiT11ksla_ yam.. nE' ISIONS �!c charige3 shall be made to th^ scorn of work ',vithoiit prior approval ,Jf Tukwila Building Division raTFE Revisions will require a new nI ?n -nd may include additional plan td 42 •fit:'?', 7 LH A -18, 20 A -1 A -22, 24 ELECTRICAL PANEL -A POWER PLAN SCALE : 1/4" = A -16 UMW t REVIEWED fOR CODE FPCO o NEC NA MDR 22 20 '14. i a ila t' TUB NOTES 1 . . i oDIG DV ISI°14 1. COORDINATE EXACT LOCATION AND TYPE OF ELECTRIC`. CONNECTION REQUIRED WITH ARCHITECT AND EQUIPMENT SUPPLIER. FILE_ P/ Permit No. I It VIP plar review approval is subject to enors and omissions. Approval of construction documents does not authorize the violation of y adopted code or ordinance. Receipt of approved Copy and conditions is acwm rig : By Date: City of Tukwila BUILDING DIVISION RECEIVED APR 18 2008 PERMIT CENTER, ELOB'-IZ8 UB\ - \\ :\k\ 633 Southcenter Seattle, WA 98188 206.246.7400 smith c©. 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithco.org/ Consultant J NGINI:ING INC. Consulting Engineers 5608 N. Charles-worth St Dearborn Hts, Michigan 48127 Tel: (313) 565 -5580 Fax: (313) 565 -9818 small:Jredengirwaring@ctomcastnat JRED PROJECT NUMBER 08028 REGISTERED ARCHITECT STATE OF WASHINGTON Consultant Registration Issues and Revisions Architect Registration No. Date Issues By Check 1 4 -11 -08 PERMITS K.S. Project Name SUBWAY Project Number 02006088.00 Description -- Computer File - Scale .,w I_u •i All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specked project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -1 ELECTRICAL - GENERAL REQUIREMENTS GENERAL: CONTRACTOR SHALL FURNISH ALL MATERIALS AND LABOR AS INDICATED ON PLANS AND AS REQUIRED FOR A COMPLETE LIGHTING AND POWER SYSTEM. EXAMINATION OF PREMISES: CONTRACTOR SHALL VISIT THE JOB SITE AND BE AWARE OF CONDITIONS UNDER WHICH HE MUST WORK. PERMITS AND FEES: CONTRACTOR SHALL OBTAIN ALL PERMITS AND PAY ALL FEES. CODES: ALL WORK SHALL BE EXECUTED AND INSPECTED IN ACCORDANCE WITH THE LATEST APPROVED EDITION OF THE NATIONAL ELECTRIC CODE, THE CODES OF O.S.H.A BARRIER FREE, A.D.A. AND ALL LOCAL AUTHORITIES HAVING JURISDICTION. UTILITY COMPANY REQUIREMENTS: COMPLY WITH CONSTRUCTION STANDARDS AND RULES OF LOCAL UTILITY COMPANIES. CONTRACTOR SHALL CONTACT UTILITY COMPANIES AND VERIFY ALL SERVICE REQUIREMENTS. INCLUDE IN BASE BID, ALL UTILITY COMPANY CHARGES. GROUNDING: CABINETS, MOTOR FRAMES, STARTERS, CONDUIT SYSTEMS, PANELS, ETC., SHALL BE GROUNDED IN ACCORDANCE WITH THE LATEST N.E.C. AND LOCAL CODES. PROVIDE SERVICE GROUND AND GROUND MAT AT PAD MOUNTED TRANSFORMER. MATERIALS: MATERIALS SHALL BE NEW AND BEAR THE U.L. LABEL OR LISTING, WHEREVER STANDARDS HAVE BEEN ESTABLISHED. AS -BUILT DRAWINGS: CONTRACTOR SHALL PREPARE AND MAINTAIN ACCURATE RECORD DRAWINGS OF ALL UNDERGROUND AND CONCEALED WORK AND SHALL SUBMIT THES DRAWINGS TO OWNER UPON FINAL ACCEPTANCE OF THE WORK OR UPON OWNER'S REQUEST. DRAWING AND MEASURMENTS: THE DRAWINGS ARE PARTLY DIAGRAMMATIC AND ARE NOT INTENDED TO BE SCALED FOR ROUGH -IN. MEASUREMENTS OR TO SERVE AS SHOP DRAWINGS. FIELD MEASUREMENTS NECESSARY FOR ORDERING MATERIALS AND FITTING THE INSTALLATION TO THE BUILDING CONSTRUCTION AND ARRANGEMENT SHALL BE TAKEN BY THIS CONTRACTOR. SHOP DRAWINGS: COMPLETE SHOP DRAWINGS FOR ALL ELECTRICAL WORK SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW BEFORE FABRICATION OF THE WORK. SEVEN (7) COPIES OF SHOP DRAWINGS SHALL BE SUBMITTED ON ALL ITEMS OF ELECTRICAL EQUIPMENT, PANELS, LIGHT FIXTURES, SPECIALTIES, ETC. CLEANING AND FINISHING: AFTER ALL TESTS HAVE BEEN MADE THE CONTRACTOR SHALL CAREFULLY MAKE A THOROUGH INSPECTION OF THE ENTIRE INSTALLATION AND HAVE THE ENTIRE WORK THOROUGHLY CLEANED, ALL RUBBISH REMOVED, AND LEAVE ALL WORK SATISFACTORY TO THE ARCHITECT AND THE OWNER. COORDINATION WITH OTHER WORK: CONSULT THE PLANS COVERING THE WORK FOR THE VARIOUS OTHER TRADES. THE FIELD LAYOUTS OF THE CONTRACTORS FOR THESE TRADES, AND THEIR SHOP DRAWINGS. THE CONTRACTOR SHALL BE AWARE AND RESPONSIBLE IN LAYING OUT THE ELECTRICAL WORK. DAMAGE TO OTHER WORK: THE ELECTRICAL CONTRACTOR WILL BE HELD RESPONSIBLE FOR DAMAGE TO WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS WORKMEN. ALL PATCHING AND REPARING OF DAMAGED WORK SHALL BE DONE BY THE GENERAL CONTRACTOR, BUT THE COST OF SAME SHALL BE PAID BY THE CONTRACTOR RESPONSIBLE FOR THE DAMAGE. TESTING: AFTER ALL ELECTRICAL WORK HAS BEEN COMPLETED. THE CONTRACTOR SHALL DEMONSTRATE TO THE ARCHITECT OR ENGINEER THAT THE ENTIRE INSTALLATION IS IN WORKING ORDER. ANY DEFECTIVE WORK OR EQUIPMENT, OR ANY WORK THAT IS NOT IN COMPLIANCE WITH THE SPECIFICATIONS, SHALL BE PROMPTLY CORRECTED BY THE CONTRACTOR. CUTTING AND PATCHING: CUTTING, CORE DRILLING, INSERTS AND CONDUIT OR CABLE SLEEVES AND PATCHING REQUIRED IN THE GENERAL CONSTRUCTION FOR COMPLETION OF THE WORK, SPECIFIED HEREIN, SHALL BE FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. CONDUIT SLEEVES: PROVIDE CONDUIT SLEEVES WHERE CONDUITS PASS THRU FLOORS, WALLS, ETC. AS REQUIRED. ALL VOIDS BETWEEN SLEEVES WHERE CONDUITS PASS THRU SHALL BE FIRESTOPPED. SPECSEAL 100 FIRE STOP SEALANT OR EQUAL. MOUNTING HEIGHTS: LIGHTING SWITCHES RECEPTACLES TELEPHONE/DATA WALL TELEPHONE LIGHTING PANELS DISTRIBUTION PANELS MOTOR STARTERS /DISCONNECT F.A. PULL STATION F.A. HORN /STROBE 4' -0" TO CENTERLINE 1-6" TO BOTTOM 1' -6" TO BOTTOM 4' -0" TO CENTERLINE 6' -6" TO TOP 7' -0" TO TOP 5-6" TO TOP 4' -0" TO TOP 80" TO BOTTOM OR 6" BELOW CLG., WHICHEVER IS LOWER. CERTIFICATE OF APPRROVAL: WHEN THE JOB IS COMPLETED, THE CONTRACTOR SHALL PROVIDE THE ARCHITECT /ENGINEER WITH CERTIFICATE OF APPROVAL FROM THE LOCAL ELECTRICAL INSPECTION AUTHORITY. THE CONTRACTOR SHALL GIVE THE OWNER A WRITTEN GUARANTEE THAT HE WILL MAKE GOOD, AT HISOWN EXPENSE, ANY DEFCETS IN MATERIALS OR WORKMANSHIP WHICH MAY DEVELOP WITHIN ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE. ELECTRICAL - BASIC MATERIALS WIRING: FEEDERS SHALL BE TYPE "THWN" OR "XHHW ". BRANCH CIRCUIT WIRING SHALL BE TYPE "THWNITHHN ", #12 MINIMUM. ALL WIRE SHALL BE COPPER, HAVE 600 VOLT INSULATION AND BE INSTALLED IN CONDUIT. GROUNDING: CABINETS, MOTOR FRAMES, STARTERS, CONDUIT SYSTEMS, PANELS, ETC., SHOULD BE GROUNDED WITH ACCORDANCE WITH THE LATEST N.E.C. AND LOCAL CODES. PROVIDE SEPARATE GROUND WIRE IN ALL CONDUITS SERVING ALL PANELS, LIGHTING, MOTORS, AND RECEPTACLES. CONDUIT: CONDUIT SHALL BE MC, THINWALL (EMT) R.G.S. OR PVC CONDUIT INSTALLED IN OR UNDER FLOOR SHALL BE 3/4" MINIMUM, R.G.S. OR PVC. CONDUIT INSTALLED IN FINISHED AREAS SHALL BE CONCEALED. FLEXIBLE METAL CONDUIT WITH GROUND WIRE SHALL BE USED FOR FINAL CONNECTION TO LIGHTING FIXTURES, MOTORS, ETC., 1/2" MINIMUM. MC CABLE MAY BE USED IN PARTITION WALL OR ABOVE ACCESSIBLE CEILINGS. NO PVC WILL BE ALLOWED IN BUILDING. ALL CONDUITS TURNING UP FROM UNDERGROUND SHALL BE STEEL ELLS. SWITCHES: SWITCHES SHALL BE 20A., 120/277V., 1 POLE, 3 AND 4 WAY AS INDICATED, IVORY FINISH, HUBBELL #1221 -1 SERIES, COOPER WIRING DEVICES OR LEVITON. RECEPTACLES: RECEPTACLES SHALL BE DUPLEX, GROUND TYPE 15A OR 20A, 125V., IVORY FINISH, HUBBEL #5362 -1 OR EQUAL. SPECIAL PURPOSE RECEPTACLES 30A, 40A, 50A, 2P, OR 3P., ECT., SHALL BE SPECIFICATION GRADE, HUBELL, COOPER WIRING DEVICES, OR LEVITON. G.F.I. RECEPTACLES SHALL BE DUPLEX GROUNDING TYPE, 20A, 125V, HUBBELL #GF5362 -1, COOPER WIRING DEVICES OR LEVITON. WALL PLATES: WALL PLATES FOR SWITCHES, AND RECEPTACLE OUTLETS SHALL BE SUPER STAINLESS STEEL, ANSI 302, HUBBELL #97000 SERIES, COOPER WIRING DEVICES, OR LEVITON. OUTLETS: OUTLET BOXES FOR CONCEALED WORK SHALL BE PRESSED STEEL BOXES, GALVANIZED #12 GAUGE. WALL OR CEILING BOXES SHALL BE 4" ROUND OR OCTAGONAL, AS REQUIRED. SURFACE MOUNTED BOXES SHALL BE CAST TYPE "FS" OR "FD ". DISCONNECT SWITCHES: DISCONNECT SWITCHES SHALL BE HEAVY DUTY, 250 VOLT, FUSED OR NON -FUSED AS INDICATED, IN A NEMA 1 ENCLOSURE. DISCONNECT SWITCHES INSTALLED OUTDOORS SHALL BE IN A NEMA 3R ENCLOSURE. SQUARE D, CUTLER HAMMER, G.E., OR SIEMENS I.T.E. FUSES: 0 TO 600 AMPERE SHALL BE PROTECTED BY CURRENT LIMITING BUSSMANN LOW -PEAK DUAL ELEMENT FUSES LPN, 250 VOLT. MOTOR CIRCUITS SHALL BE PROTECTED BY BUSSMANN LOW -PEAK DUAL - ELEMENT FUSES LPN, 250 VOLT. CIRCUIT BREAKER PANELS SHALL BE PROTECTED BY BUSSMANN LOW -PEAK DUAL - ELEMENT FUSES LPN, 250 VOLT. RECEPTACLE PANEL: PANELS SHALL BE 120/208V., 3 PHASE, 4 WIRE, WITH BOLT -ON CIRCUIT BREAKERS RATED 10,000 A.I.C. SWITCH DUTY RATED, 20" WIDE CABINET MINIMUM. SQUARE D "NQOD ", CUTLER HAMMER, G.E. OR SIEMENS I.T.E. PROVIDE TYPEWRITTEN DIRECTORY INDICATING EACH ITEM SERVED. NAMEPLATES: PROVIDE NAMEPLATES ON EACH INDIVIDUAL SAFETY SWITCH, CONTROL STATION, PANEL BOARD, MOTOR STARTER, ETC. NAMEPLATES SHALL BE WHITE LAMINATED PLASTIC WITH BLACK ENGRAVED LETTERS AND A SELF- ADHESIVE BACK. LIGHTING LAMPS: FLUORESCENT LAMPS SHALL BE ENERGY SAVING TYPE, 3500K COLOR TEMPERATURE AND 73 COLOR RENDERING INDEX, GENERAL ELECTRIC SP35WM, PHILLIPS OR OSRAM /SYLVANIA. BALLAST: FLUORESCENT LAMP BALLAST SHALL BE ENERGY SAVING ELECTRONIC TYPE, G.E., MOTOROLA, ADVANCE OR MAGNETEK. SYSTEMS TELEPHONE SERVICE: TELEPHONE/DATA SERVICE SHALL BE BY OWNERS TELEPHONE/DATA CONTRACTOR. MISCELLANEOUS ELECTRICAL DEMOLITION: ALL ELECTRICAL DEMOLITION WORK SHALL INCLUDE REMOVING AND /OR RELOCATING OF EXISTING PANELS, LIGHTING FIXTURES, RECEPTACLES, WIRE, CONDUIT, BOXES, ETC., AS INDICATED ON THE DRAWINGS AND SHALL BE BY THE ELECTRICAL TRADE THAT WOULD NORMALLY INSTALL THIS WORK. REMOVE ALL CONDUIT, WIRE, HANGERS, CLAMPS, ETC., THAT ARE NOT BEING REUSED, UNLESS CONCEALED ABOVE CEILINGS OR IN WALLS, WHICH MAY BE ABONDONED AND LEFT IN PLACE. REMOVE ALL WIRE IN EXISITING CONCEALED ABANDONED CONDUITS, EXISITNG CONCEALED CONDUITS (IF APPLICABLE) MAY BE REUSED FOR NEW WIRING. ALL EXISITNG PANELS, LIGHTING FIXTURES, WIRING DEVICES, TELEPHONE OUTLETS, ETC., SHALL REMAIN IN THEIR EXISTING LOCATIONS, UNLESS OTHERWISE NOTED. REMOVE EXISTING WIRING DEVICES, PULL ALL WIRES OUT AND INSTALL A BLANK STAINLESS STEEL COVER PLATE OVER THE EXISTING OUTLET. REVISE PANEL DIRECTORIES AS REQUIRED TO REFLECT ALL REVISIONS TO EXISITNG PANELS. ALL MATERIALS THAT ARE REMOVED, PANELS, LIGHTING FIXTURES, WIRING DEVICES, CONDUIT, WIRE, ETC., SHALL BECOME THE PROPERTY OF ALL CONTRACTOR, UNLESS OTHERWISE NOTED ONT HE DRAWINGS. KITCHEN EQUIPMENT: VERIFY ALL ROUGH -IN LOCATIONS, FINAL CONNECTIONS, MOUNTING HEIGHTS, VOLTAGE AND PHASE PRIOR TO THE INSTALLATION WITH KITCHEN EQUIPMENT SUPPLIERS SHOP DRAWINGS. FAILURE TO DO 50 SHALL RESULT IN NO EXTRA CHARGE TO THE OWNER. PROVIDE AND INSTALL 3- CONDUCTOR CORDS AND CAPS FOR MISCELLANEOUS COUNTER, MOUNTED KITCHEN EQUIPMENT. VERIFY WITH KITCHEN EQUIPMENT SUPPLIERS SHOP DRAWINGS. 633 Southcenter Seattle, WA 98188 206.246.7400 smith cc). 318 terry avenue n seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant NGIN MING INC. Consulting Engineers 5608 N. Chariesworth St Dearborn Fits. Michigan 48127 Tel: (313) 565 -5580 Fax: (313) 565 -9818 emaA:Jredenglneering@comcastnet JRED PROJECT NUMBER 08028 6294 REGISTERED ARCHITECT STATE OF WASHINGTON Consultant Registration COIDE COMPLIANCE. WA 70 APR 44 4 City -Df TUIV4Il,�D� ILDDN ELOBHZ8 RECErWEP. APR 18 2008 PERMIT CENTEh Issues and Revisions Architect Registration No. Date Issues By Check 1 4 -11 -08 PERMITS K.S. Project Name SUBWAY Project Number 02006088.00 Description Computer File Scale • empl to All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -2