Loading...
HomeMy WebLinkAboutPermit EL08-0439 - WESTFIELD SOUTHCENTER MALL - GENERAL NUTRITION CORPORATION (GNC)GENERAL NUTRITION CORPORATION 978 SOUTHCENTER MALL ELO8-439 Cityllif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 978 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -439 Issue Date: 07/09/2008 Permit Expires On: 01/05/2009 Tenant: Name: GENERAL NUTRITION CORP Address: 978 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MARTHA MARTIN Phone: 310 - 328 -6300 X104 Address: 1327 POST AVE SUITEH , TORRANCE CA Contractor: Name: ABACUS ELECTRIC LLC Phone: 253 - 984 -1611 Address: 9804 SALES RD S STE A -1 , LAKEWOOD WA Contractor License No: ABACUEL967DA Expiration Date: 03/01/2010 DESCRIPTION OF WORK: CONNECT NEW FIXTURES TO EXISTING LIGHTING CIRCUIT. FURNLSH AND INSTALL A DUPLEX RECEPTACLE AND CEILING HOOK WITH NON - COMBUSTIBLE BLOCKING Value of Electrical: $12,500.00 Type of Fire Protection: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $369.00 2005 Date: **-1-9— 0 8 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. Signature: Date: 7 A/0 T6 Print Name: rAca S This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -439 Printed: 07 -09 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 978 SOUTHCENTER MALL TUKW GENERAL NUTRITION CORP PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -439 ISSUED 04/22/2008 07/09/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: Date: '1/4 if)t. doc: Cond -Elec EL08 -439 Printed: 07 -09 -2008 CITY OF TUKWILI Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www.ci.tukwila.wa us • Etettrirat Periittt No. Project No. LQO- ; Lt3c DO -0q0 (For o iice trse an,0 ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION 9 1 King Co Assessor's Tax No.: ' 3.4. `f» ` �D / 6 Site Address: u "\ Le��e� 1 ��� 11 Suite Number :__ Floor: C- c..>' e tr0.\ i J u r ( C o (` ((rA)C) New Tenant: ❑ Property Owners Name: Sc( /1-Al■ C:e �'�P % ►vice 11 Mailing Address: q l■ SOO l - NeA.A1 11) t City Tenant Name: Yes wk State Le tml T'e d' Zip CONTACT PERSON.- Who de we contact when :emir pe iistisd tady to «r stied Name: f .c&f & /liar /� L ,, Mailing Address: 1 301 / 7.- PO St e l w2 • E -Mail Address: / f. 1 et Q �/] r$$ Day Telephone: (3) o� 'd !aey fa( te 9050 City State Zip Fax Number:(-3 h') � o� C 3 315 ELECTRICAL CONTRACTOR .INEORMATIO 1 Company Name: Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 2-150C1 Scope of Work (please provide detailed information): C O rt dl -Q,G1 1 t -1 \'01'e S 40 P f 5- kV\ \.J q cl\rtvt Vt;sS 1.1 & C / L' ' #7 C _e ar, /9(ail STe• dr t'cgi P; i' Ark w/ii Ce(h o r v5 s �° Will se ice be altered? ❑ Yes �4C��✓� for 5?fir," PLoa -r 6�Ie lid- 9)/54-e r1 g 1 47110r ❑ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ❑ Fire Alarm ❑ Low Voltage ❑ Generator Property Served by: k Puget Sound Energy ❑ Seattle City Light H.WpplicationaWonn- Applications On Line\4 -2007 - Electrical Pmmt Applica5m.doc bh Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings (including an attached garage) ❑ Garages, pools, spas and outbuildings $140.00 $75.00 ea $55.00 ea ❑ Low voltage systems (alarm, fumace thermostat) RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) 575.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature Print Name: rp -j roa n Joffe t-\ Mailing Address: t27 r%5-> , Date: o `1 I I a)'o er r Day Telephone: 310 - 328.G3e.zi � • �C�.� -�aY rq ncaeo l City S Zip Date Application Accepted: LA�d���j/ Date Application Expires: Oa Staff Initials: ( /,q n AApplicabauTon - Appliatimu On Line %4-2007 - Mectri®l Permit Applicafian.dac bh Page 2of2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -439 Address: 978 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/22/2008 Applicant: GENERAL NUTRITION CORP Issue Date: Receipt No.: R08 -02475 Payment Amount: $295.20 Initials: WER Payment Date: 07/09/2008 10:21 AM User ID: 1655 Balance: $0.00 Payee: ABACUS ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5003 295.20 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 295.20 Total: $295.20 4611 07/09 0'711 TOTAL 295.20 doc: Receipt -06 Printed: 07 -09 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -439 Address: 978 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/22/2008 Applicant: GENERAL NUTRITION CORP Issue Date: Receipt No.: R08 -01265 Payment Amount: $73.80 Initials: WER Payment Date: 04/22/2008 11:00 AM User ID: 1655 Balance: $295.20 Payee: EXPRESS PERMITS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 11486 73.80 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 73.80 Total: $73.80 1472 04/22 9710 TOTAL 73.80 doc: Receiot -06 Printed: 04 -22 -2008 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. IV CITY OF TUKWILA BUILDING DIVISION 11-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 - 61j0 E1.raB- y3, Project: G NC Type of Inspection: Address: 971 tilitt, Date Called: Special Instructions: Date Wanted: b j cai:.ren. Requester: Phone No: KApproved per applicable codes. D Corrections required prior to approval. COMMENTS: epicq.€CT 04s yvvp Inspector: oeddri Date: f 03 /d1. ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit Eti - I3' INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION P. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �. .�. Type of Inspection: ;loo TA-Pt Win -11%/m kccisSIa(E Address: I Ai, ri Date Called: - La4GZ PAtisiel Tb rat DK-4TE /,Jir Ab4Q.6-33 D v4 skeet rep F401 Special Instructions: Date Wanted: y v a.m. I Requester: Phone No: ElApproved per applicable codes. ICI Corrections required prior to approval. COMMENTS: - pisc4'it( -r , frac 0i - 1t)6 '1+F1 i 50 L.hriti, A/t it wI %/ Win.) TA-Pt Win -11%/m kccisSIa(E - 11._" srovr 5rR(' O A PA4 - %oe7Jrtf'j Q . 401662_5 a Adel._ - La4GZ PAtisiel Tb rat DK-4TE /,Jir Ab4Q.6-33 D v4 skeet rep F401 - 1., WI- kePfic eta, LAJ I m otter poi, - cii,KAPt,r -S n►SStn%,1 J 15 - LAJWQI LL( ITl PJti 6$2,44CtiON $al h' P - 1i TS 14 c fCCX it.DocTOIN 4141r Inspector: Date: o z or El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: [Date: INSPECTION RECORD Retain a copy with permit etov-Li31 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -36170 3 Project bi tt1Q,� cop. Type of Inspection: 70a3 Address: ti l Q mom, Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: IDApproved per applicable codes. El Corrections required prior to approval. P4 C r ati,044 �� 541.45 LoO odi.1 COMMENTS: Inspector: / (Date: o /I s 0'p El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit 6°V.- INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: hN h V t'\ `ilodType of Inspection: 7Da Addres : toot/ Date Called: - sty S rttc, tettiz.4,619 a t, Special Instructions: Date Wanted: ��) a:m Requester: Phone No: DApproved per applicable codes. ViCorrections required prior to approval. COMMENTS: — _56V1+Ci I c 9 AT r o/T - sty S rttc, tettiz.4,619 a t, - sctsri'c, 415TirJL\ 5TgoPS 14 64c.& K001 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: .ti INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 eL01 -y31 ti Project j 4.11. MOW Type of Inspection: Address:978 Date Called: Special Instructions: Date Wanted:�0� a.m Requester: (( Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: 0.K 5r6e6rizoAkr socrer Inspector: 6e7VAIerk, Date: I ChioG oi, ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: —mar - u — _ _._. _ ... _ _. . _.. � ...1L.1.41 - — _ ,�.. .1ft 2006 Washington State Nonresidential Energy Code Com•Iiance Form P;roj,ect Summary 2008 Washington State Nonresidential Energy Code Compl lance Forms PRJ -SUM Revised July 2007 Project Info Project Address South Center ball Date 4/14/2008 1.7.5.i'' South Center Mall ,--aa .u408. For Building Department Use Tukwila, WA 98188 Applicant Name: General Nutrition Center Applicant Address: 300 Sixth Avenue, Pittsburgh, Pa 15222 Applicant Phone: (412) 288 -4769 / Chad Cox �i�� COPRA • 8492 4-I1slob REGIS i ERED ARCIHI ECT GREG T. Su' STATE OF V ; ;`'- -1:N ELO8�11?, 9 ECEWEr APR 22 2008 PERMIT CENTE- 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Sur, Lary 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Project Info Project Address South Center Mall Date 4/14/2008' 911 South Center Mall, space #308 For Building Department Use Tukwila, WA 98188 Applicant Name: General Nutrition Center Applicant Address: 300 Sixth Avenue, Pittsburgh, Pa 15222 ApplicantPhone: (412) 288 -4769 / Chad Cox Project Description l01 ❑ Plans Included requirements. ❑ New Building - Addition ❑ Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area loo Sales Area 3.00 882.0 2646.0 l01 Service Area 0.50 124.0 62.0 102 Toilet Room 0.80 40.0 32.0 "' From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2740.0 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 100A - 2'x2' Fluorescent 7 75.0 525.0 E - 4' Fluorescent 10 80.0 800.0 C - Incandescent Downright 10 75.0 750.0 F - Track Head 41 50w /ft 8 50.0 400.0 1O1D - 4' Fluorescent 2 64.0 128.0 102Z - Toilet Light /Fan 1 60.0 60.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2663.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. a' (s 08 K492 Fire S I ERED ARChiTECT GREG T. cud ii STATE OF 4',AS 1:,N. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Sun (back) LTG -INT 2008 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 • Prescriptive Spaces Occupancy: Q Warehouses. storage areas or aircraft storage hangers Q Other Qualification Checklist Chklist Note: If occupancy type is "Other" and fixture Lighting Fixtures: 95% ❑ Check If 9510 or more of fixtures comply with 1,2 or 3 and rest are ballasted. answer is checked, the number of fixtures in (Section 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps. b) reflector the space is not limited by Code. Clearly 1521) or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- indicate these spaces on plans. If not 1.2 tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. qualified. do LPA Calculations. Cafeterias, fast food establishments5, restaurants /bars5 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts Post office 1.1 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPAz (W /sf) Automotive facility 0.9 Office buildings, office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5•7•11 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations 1.0 Cafeterias, fast food establishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia`, assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses", storage areas 0.5 Hotel banquet/conference /exhibition hall5•4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries° 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 ootnotes for Table 15 -1 1) in cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, u otherwise by subsequent footnotes. 3) 4) 5) 6) 7) 8) 9) specific Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. Reserved. For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of Reserved. For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall), b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. �p8 Iyiltr_VOEF'=D ARCHITECT GREG T, STATE OF4• h; 1. rt area is PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -439 DATE: 04 -22 -08 PROJECT NAME: GENERAL NUTRITION CORP SITE ADDRESS: 978 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS,:{ -e B l• ng (vision Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator n 'r1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -24 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS R UTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -22 -08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by Lal to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. ABACUS ELECTRIC LLC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company ABACUS ELECTRIC LLC 2539841611 9804 SALES RD S STE A -1 LAKEWOOD WA 98499 PIERCE LIMITED LIABILITY COMPANY UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602371073 ACTIVE ABACUEL967DA ELECTRICAL CONTRACTOR 3/1/2004 3/1/2010 GENERAL UNUSED Business Owner Information Name Role Effective Date Expiration Date OUELLETTE, MARK R PARTNER /MEMBER 03/01/2004 Bond Amount OUELLETTE, GARY B PARTNER /MEMBER 03/01/2004 3 -670- 237 Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 OHIO CAS INS CO 3 -670- 237 03/01 /2004 Until Cancelled 03/01/2008 $4,000.00 03/01/2004 https: // fortress .wa.gov /lni/bbip/Detail. aspx ?License= ABACUEL967DA 07/09/2008 �1U SEM MUM ■ ■a P -I3 (E)P-11 SCALE: 1/4' = 11-0" GENERAL LIGHTING NOTES: GX (E)P -10 GX (E)P -I0 111111 111111 NEW RECESSED WALLWASHER AGGENT LIGHT FIXTURES SF F DETAIL 2/E -2 FURN. 1=3Y GNG I. ALL EXIT 4 EMERGENCY LIGHTS SHALL SE CONNECTED TO NIGHTLIGHT GIRGUIT "P -14" 4 REMAIN UN- SWITCHED. GO OS 00 ED P-I' i P -I6 ; 3/4" G. W/ ONE PHASE CONDUCTOR, NEUTRAL AND INSULATED GROUND FOR ISOLATED RECEPTACLES. P -IS ; 3/4" G. W/ ONE PHASE CONDUCTOR, NEUTRAL AND GROUND FOR RECEPTACLES COOLER. TO TELEPHONE BOARD ✓ ALL HOMERUNS FROM GASHWRAP SHALL BE IN SEPARATE CONDUITS POWER PLAN SCALE: 1/4" = 1 ' -d " 00 P -5 RUN GIRGUIT THRU TIMEGLOGK be rr1c.• of work '.,vitholut prior approv7.I -)f Tukwila Building Division NOTE: Revisions will requirn a new pl2n sl!hn -0'11 and may include additional plan rrrr., ": f;7^ EPARATE PERMIT REQUIRED FOR: S , Mechanical ❑ Electrical iV Iumbing gar Gas Piping City of Tukwila BUILDING DIVISION REVIEWED 1PLI�CE FOR CODE CO NFPA 70 - NEC APR 2 6 20 Of Tukwila DING pNj ION F -OPT Permit P1�L 0. � Plar review approval Is subleat to errors and omissions. Approval of construction documents does �a the violation of any adopted of approved Fie% Copy and s ondi ofs is -:. :: 4edcjed: City Of Tukwila BUILDING DIVISION EL.0- `i39 RECEIVED APR 2 2 2008 PERMIT CENTER ENCv 4 POWER ‹ r) NOTES I� J -BOX 30A /2P /II5V/NF/N -I DISCONNECT SWITCH TO SE MOUNTED WITHIN 6' -0" OF BULKHEAD. TRANSFORMER AND FINAL CONNECTION BY ELEGTRIGAL CONTRACTOR. SIGN ON TIME CLOCK BY E.G. ® E.G. SHALL FIELD VERIFY EXACT REQUIREMENTS FOR SMOKE/FIRE ALARM SYSTEM. REUSE ANY EXISTING DETECTION SYSTEM. REPLACE ANY DEFECTIVE DEVICES. IF THERE IS NOT AN EXISTING SYSTEM, E.G. SHALL SUPPLY AND INSTALL ALL NECESSARY EQUIPMENT (SMOKE DETECTORS, AUDIOVISUAL ALARMS, FIRE ALARM PANEL, CONDUIT, WIRE, ETC.) FOR. A NEW SYSTEM AS MAY SE REQUIRED BY LANDLORD AND /OR LOCAL FIRE MARSHALL. FIELD VERIFY AND COORDINATE. �3 I CONDUIT FROM COOLER TO NEAREST WALL , G.G. TO INSTALL OUTLET W/ GOVERPLATE FLUSH IN GASHWRAP. COORDINATE W/ GNG ® E.G. SHALL FURNISH AND INSTALL A DUPLEX RECEPTACLE AND "CEILING" HOOK W/ NON- COMBUSTABLE BLOCKING FOR SUPPORT, MOUNTED IN CEILING FOR SUSPENDED NEON SIGN OR FOR GABLE SYSTEM SIGN IN STOREFRONT SHOW WINDOW. FIELD VERIFY EXACT LOCATION. O DUPLEX RECEPTACLE FLUSH MOUNTED IN WALL AT IS" A.F.F. • EXISTING G.F.G.I. DUPLEX RECEPTACLE FLUSH MOUNTED AT 42" A.F.F. • FIELD VERIFY EXACT LOCATION OF LANDLORD TELEPHONE SERVICE STUB -IN AND EXTEND AS REQUIRED FOR CONNECTION TO TENANT TELEPHONE EQUIPMENT. PROVIDE 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF ELECTRICAL AND TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE ISOLATED GROUND DUPLEX REGEPTAGLE FOR POWER TO TELEPHONE EQUIPMENT. 10 it IZ 13 14 15 16 17 18 EXISTING ELECTRICAL SERVIGE REFER TO ELECTRICAL RISER DIAGRAM SHEET E.2 EXISTING 1-50X 30A/2P /II5V/NF/N -I DISCONNECT SWITCH FOR WATER HEATER. J -BOX 4 60A/2P /208V/FUSED 50A/N -I DISCONNECT SWITCH FOR AIR HANDLING UNIT. J -SOX 60A/2P/208V/FUSED 35A/N -3R DISGONNEGT SWITCH ON ROOF FOR GONDENSING UNIT. EXISTING WEATHER PROOF RECEPTACLE NEAR UNIT. DUPLEX RECEPTACLE FLUSH MOUNTED IN WALL AT 36" A.F.F. FOR MANAGER'S DESK UNIT. FIELD VERIFY LOCATION WITH FIXTURE INSTALLER AND G.G. TRENCH /GORE DRILL FLOOR AS REQUIRED. CONNECT NEW LIGHT FIXTURE TO EXISTING LIGHTING CIRCUIT. RE -WIRE EXISTING CIRCUIT TO NEW CIRCUIT SHOWN TO, BALANCE PANEL LOAD. GONNEGT NEW FIXTURE TO EXISTING GIRGUIT. DUPLEX RECEPTACLE RECESSED MOUNTED IN HALL APPROXIMATELY 8' -O" A.F.F. GENTERED OVER THE REAR SALES /SERVICE DOOR 50 THE LIGHT BOX GAN LAY FLAT AGAINST THE WALL. THE EXIT SIGN SHALL BE MOUNTED OR RE- LOCATED (IF EXISTING) AS CLOSE AS POSSIBLE TO THE CEILING TO PROVIDE CLEARANCE FOR LIGHTBOX. a u 2 c3 w W V P-- ccD CIO r) re, N 7C Li w CD CL- 5 0 0 H z_ 0 Q z J 0 Cfl 0 z SY ce U on w w O O O w Store No. 5288 Drawn by: MWS Checked By: RR Date: 6/7/2007 Date: DATE CHECKED Drawing Name: 05288.DWG Drawing No. 60" APPROX. I' X 4' WALL WASHER. FIXTURE IS TO ILLUMINATE WALL FIXTURES ONLY. DEMISING WALL FINISH FLOOR TYP. CEILING @ IO' -O" A.P.P. TYPICAL I x 4' E -2 NO SCALE AIALLI\ASHER INSTALLATION CASH /WRAP LEGEND O O O CO INDICATES 2 GANG JUNCTION BOX INDICATES JUNCTION BOX CASH /WRAP GENERAL NOTES 1. HOLES FOR POS #1, #2 AND ISP CABLE(S) TO BE 2 1/2" DIA. 2. CABINET WORK BY GNC AND INSTALLATION BY GNC GENERAL CONTRACTOR (GC). ELECTRICAL CONTRACTOR TO VERIFY PROPOSED LOCATION OF CASHWRAP W /GNC GC PRIOR TO INSTALLING ELECTRICAL DEVICES. 3. THESE DETAILS ARE FOR A TYPICAL CASH /WRAP INSTALLATION. E.C. SHALL FIELD VERIFY EXACT LOCATIONS, CONFIGURATIONS AND REQUIREMENTS WITH G.C. AND GNC PROJECT REPRESENTATIVE FOR STORE SPECIFIC CASH /WRAP. Kva x 1000 - 57 Amp Volts x 1.15 Amps x Feet x 10 - - VD. x P.F. Y - - GM Min. Code Size i2eguired = MG = GM Feeder = 4 No. 2 + 8 GW - 2" G Feeder Switch = 100 Amp 3 Pole 100 Fuse Feeder CS Amp Pole Notes/Remarks EXISTING SERVICE TO REMAIN Spares and Spaces Galculated at %i of Circuit Ampere Rating x Circuit Voltage x Number of Poles Outlets: 120V 15 4 20amp Receptacles: I&OVA 120V 15 ff 20amp Outlets: I000VA 205V 15 4 20amp Outlets: 3000VA Transformer Feeder: 1"i /a KVA / Y FLA (primary) x 1.25 = - Ampere Use - No. - 4 No. - Ground 8 - Ampere GB DEMAND DESIGN KW LOAD GON'D KW FACTOR SUMMER WINTER Lighting 4.76 1.25 5.15 5.15 Receptacles 3.G6 1.00 3.42 3.42 Transformers - -- 1.00 - -- - -- Motors 0.14 1.00 0.1 0.1 Heating E3.0 L00 >< 8.0 Air Gondition 5.8 1.00 513 >< Miscellaneous - -- 050 ----- - -- Spare 4 Spaces --- 050 --- - -- Kitchen -- 0.10 - -- - -- Water Heater 1.5 1.00 15 15 Signs 1.2 1.25 15 15 TOTAL 25.36 1821 20.47 SYMBOL LESEND 111 • -vG 0` GFI N.L. T/G DUPLEX RECEPTACLE DEDICATED RECEPTACLE FLUSH MTD FLOOR RECEPTACLE TELEPHONE OUTLET JUNCTION BOX 24HR 7 DAY -TIME CLOCK DISCONNECT SWITCH TEL EPHONE BOARD ELECTRICAL PANEL 3 #I2, I /2 "G (2 GKT WIRES AND I NEUTRAL) HOME RUN CONDUIT STUBBED UP CONDUIT STUBBED DOWN GROUND FAULT INTERRUPTER NIGHT LIGHT TIMEGLOGK CONTRACTORS NOTE UPON RECEIVING FIXTURES FROM ONG, THE E.G. SHALL IMMEDIATELY NOTIFY GNG OF ANY ADDITIONAL LIGHTING FIXTURES AS REQUIRED BY THE LIGHTING PLAN. ALL FIXTURES TO BE INSTALLED PRIOR TO FINAL INSPECTIONS. LIGHT FIXTURE SCHEDULE LAMP SCHEDULE SYMBOL TYPE DESCRIPTION MANUFACTURER CATALOG NO. VOLTS MOUNTING DESCRIPTION it of TOTAL LAMPS WATTS MEM MEM A 2 x 2 FLUORESCENT W/ a CELL PARABOLIC LENSES LIGHTOLIER DPA2GgL52FT (120/2T705) ADV RGN- 2TfP40 -SG 2L 120/2T1 REG FT40T5 /S35 5IAX 2 15 MUM ■ ■ ■ ■ ■■ MINIMUM AA 2 x 4 FLUORESCENT IN/ a CELL PARABOLIG LENSES LIGHTOLIER DPA2G171 5232 (120/2T105) ADV ING 2P325G GEN 2L 120/271 REG T8\321,1\855 2 5cf B 2 X 2 FLUORESCENT IN/ PRISMATIG AGRYLIG LENSE LIGHTOLIER SPS2GFSVA2FT (120/2T105) ADV RCH- 2T1P40 --SG 2L 120/211 REG FT40T5/835 BIAX 2 15 -■a BB 2 X 4 FLUORESGENT IN/ PRISMATIC ACRYLIC LENSE LIGHTOLIER SP52GFSVA232 (120/21105) ADV ING 2P325G GEN 2L 120/211 REG T8/32W/835 2 0 G RECESSED 6" OPEN DOWNLIGHT PAR INN/ FRAME KIT LIGHTOLIER G6l30DGLW/ G6120 120 REG PAR 30/151N/1-1IR SHORT NEGK 15 48" TWO LAMP OPEN STRIP LIGHT LIGHTOLIER S1N45232HPFUNVGA ADV INC 2P325G GEN 2L 120/211 SUR TS/521/855 2 64 l ►� E= '1^IALMASTER' 2' WALLINASHER LIGHTOLIER WMRLI24120CD ADV RCN- ITTP4O -SG IL 120/211 REG FT4ODL /835/x5 40 I_ 1 EE 'WALMASTER' 4' WALL.WASHER LIGHTOLIER WMRL2441205B GONG 120/211 REG FT40DL /835/x5 2 80 0 F SINGLE GERAMIG METAL HALIDE WALL WASHER LIGHTOLIER 83W1UWH\ 83B105EWH 120 PEN/TRK EDI1P /GMH/MED/30K 10 G SINGLE CERAMIC METAL HALIDE ENCLOSED SPOT LIGHTOLIER 8311U1NH\831310 SEfr'JH /83ED Itf5/ AL4HG 120 PETVIRK EDI1P /GMH/MED/30K 10 u 0 0 H 26" - 2 LAMP BIAX TRAC HEAD LIGHTOLIER 521cfENINH. 120 PEN/TRK P T4ODL /835/RS 2 80 J GIMBOL RING TRACK HEAD LIGHTOLIER g023WH 120 PEN/TRK 15 PAR 30 /GAP/ SPL/MFL25 75 0 K GALGULITE INCANDESCENT ADJUSTABLE ACCENT LIGHTOLIER AA1CLII30/ PAA1P5BD 120/211 REG PAR38/151WI -fIR 15 T2 24" ONE GIRGUIT, SURFACE TRAG WHITE, 11/60841 GLG CLIP LIGHTOLIER 6000WH 120 SUR NOT APPLIGABLE 11 T4 48" ONE GIRGUIT, SURFACE TRAG WHITE, IN/608g GLG CLIP LIGHTOLIER 6001 WH 120 SUR NOT APPLICABLE TS G6" ONE GIRGUIT, SURFAGE TRAG WHITE, IN/608q GLG CLIP LIGHTOLIER 6002K -f 120 SUR NOT APPLICABLE EM -I L.E.D. EXIT SIGN DUALITE 120/211 SUR INCLUDED 3 EM -2 EM -3 LED. 'EXIT' SIGN IN/ DUAL EMERGENCY LIGHTS, - GIOMIN. BATTERY BAGKUP DUAL EMERGENCY LIGHTS, - gOMIN. BATTERY BACKUP DUALITE DUALITE LIURW EZ -2 120/211 120/211 SUR SUR INGLUDE D INCLUDED 2 2 5 5 z EXHAUST FAN/LIGHT COMBINATION NUTONE 8664RP 120 REG 601N AID{ 155 PANEL No. D DOUBLE= I I LOCATION MAIN IDOA MAIN LUG E ENCLOSURE SERVICE ❑ phase 4 w►re p wire c circ s p5 p pole F FOR p phase load F FOR n noc a anps p pole S DEMAND DESIGN KW LOAD GON'D KW FACTOR SUMMER WINTER Lighting 4.76 1.25 5.15 5.15 Receptacles 3.G6 1.00 3.42 3.42 Transformers - -- 1.00 - -- - -- Motors 0.14 1.00 0.1 0.1 Heating E3.0 L00 >< 8.0 Air Gondition 5.8 1.00 513 >< Miscellaneous - -- 050 ----- - -- Spare 4 Spaces --- 050 --- - -- Kitchen -- 0.10 - -- - -- Water Heater 1.5 1.00 15 15 Signs 1.2 1.25 15 15 TOTAL 25.36 1821 20.47 SYMBOL LESEND 111 • -vG 0` GFI N.L. T/G DUPLEX RECEPTACLE DEDICATED RECEPTACLE FLUSH MTD FLOOR RECEPTACLE TELEPHONE OUTLET JUNCTION BOX 24HR 7 DAY -TIME CLOCK DISCONNECT SWITCH TEL EPHONE BOARD ELECTRICAL PANEL 3 #I2, I /2 "G (2 GKT WIRES AND I NEUTRAL) HOME RUN CONDUIT STUBBED UP CONDUIT STUBBED DOWN GROUND FAULT INTERRUPTER NIGHT LIGHT TIMEGLOGK CONTRACTORS NOTE UPON RECEIVING FIXTURES FROM ONG, THE E.G. SHALL IMMEDIATELY NOTIFY GNG OF ANY ADDITIONAL LIGHTING FIXTURES AS REQUIRED BY THE LIGHTING PLAN. ALL FIXTURES TO BE INSTALLED PRIOR TO FINAL INSPECTIONS. LIGHT FIXTURE SCHEDULE LAMP SCHEDULE SYMBOL TYPE DESCRIPTION MANUFACTURER CATALOG NO. VOLTS MOUNTING DESCRIPTION it of TOTAL LAMPS WATTS MEM MEM A 2 x 2 FLUORESCENT W/ a CELL PARABOLIC LENSES LIGHTOLIER DPA2GgL52FT (120/2T705) ADV RGN- 2TfP40 -SG 2L 120/2T1 REG FT40T5 /S35 5IAX 2 15 MUM ■ ■ ■ ■ ■■ MINIMUM AA 2 x 4 FLUORESCENT IN/ a CELL PARABOLIG LENSES LIGHTOLIER DPA2G171 5232 (120/2T105) ADV ING 2P325G GEN 2L 120/271 REG T8\321,1\855 2 5cf B 2 X 2 FLUORESCENT IN/ PRISMATIG AGRYLIG LENSE LIGHTOLIER SPS2GFSVA2FT (120/2T105) ADV RCH- 2T1P40 --SG 2L 120/211 REG FT40T5/835 BIAX 2 15 -■a BB 2 X 4 FLUORESGENT IN/ PRISMATIC ACRYLIC LENSE LIGHTOLIER SP52GFSVA232 (120/21105) ADV ING 2P325G GEN 2L 120/211 REG T8/32W/835 2 0 G RECESSED 6" OPEN DOWNLIGHT PAR INN/ FRAME KIT LIGHTOLIER G6l30DGLW/ G6120 120 REG PAR 30/151N/1-1IR SHORT NEGK 15 48" TWO LAMP OPEN STRIP LIGHT LIGHTOLIER S1N45232HPFUNVGA ADV INC 2P325G GEN 2L 120/211 SUR TS/521/855 2 64 l ►� E= '1^IALMASTER' 2' WALLINASHER LIGHTOLIER WMRLI24120CD ADV RCN- ITTP4O -SG IL 120/211 REG FT4ODL /835/x5 40 I_ 1 EE 'WALMASTER' 4' WALL.WASHER LIGHTOLIER WMRL2441205B GONG 120/211 REG FT40DL /835/x5 2 80 0 F SINGLE GERAMIG METAL HALIDE WALL WASHER LIGHTOLIER 83W1UWH\ 83B105EWH 120 PEN/TRK EDI1P /GMH/MED/30K 10 G SINGLE CERAMIC METAL HALIDE ENCLOSED SPOT LIGHTOLIER 8311U1NH\831310 SEfr'JH /83ED Itf5/ AL4HG 120 PETVIRK EDI1P /GMH/MED/30K 10 u 0 0 H 26" - 2 LAMP BIAX TRAC HEAD LIGHTOLIER 521cfENINH. 120 PEN/TRK P T4ODL /835/RS 2 80 J GIMBOL RING TRACK HEAD LIGHTOLIER g023WH 120 PEN/TRK 15 PAR 30 /GAP/ SPL/MFL25 75 0 K GALGULITE INCANDESCENT ADJUSTABLE ACCENT LIGHTOLIER AA1CLII30/ PAA1P5BD 120/211 REG PAR38/151WI -fIR 15 T2 24" ONE GIRGUIT, SURFACE TRAG WHITE, 11/60841 GLG CLIP LIGHTOLIER 6000WH 120 SUR NOT APPLIGABLE 11 T4 48" ONE GIRGUIT, SURFACE TRAG WHITE, IN/608g GLG CLIP LIGHTOLIER 6001 WH 120 SUR NOT APPLICABLE TS G6" ONE GIRGUIT, SURFAGE TRAG WHITE, IN/608q GLG CLIP LIGHTOLIER 6002K -f 120 SUR NOT APPLICABLE EM -I L.E.D. EXIT SIGN DUALITE 120/211 SUR INCLUDED 3 EM -2 EM -3 LED. 'EXIT' SIGN IN/ DUAL EMERGENCY LIGHTS, - GIOMIN. BATTERY BAGKUP DUAL EMERGENCY LIGHTS, - gOMIN. BATTERY BACKUP DUALITE DUALITE LIURW EZ -2 120/211 120/211 SUR SUR INGLUDE D INCLUDED 2 2 5 5 z EXHAUST FAN/LIGHT COMBINATION NUTONE 8664RP 120 REG 601N AID{ 155 PANEL No. D DOUBLE= I I LOCATION MAIN IDOA MAIN LUG E ENCLOSURE SERVICE ❑ phase 4 w►re p wire c circ s p5 p pole F FOR p phase load F FOR n noc a anps p pole S Size A 5 5 G G p #& 1 1 S SO A AIR HANDLING UNIT < 4 4000 C CONDENSING UNIT 2 2 3 35 # #g 2400 4 #a �� 11 11 2 4000 1 11 11 4 4 2 #8 3 3 � 2100 #12 5 5 2 20 1 1 S SIGN 1 1200 T TRACK LIGHTS 6 6 2 20 1 1 * *12 400 #I2 1 1 2 20 1 1 S SALES LIGHTS I SYMBOL LESEND 111 • -vG 0` GFI N.L. T/G DUPLEX RECEPTACLE DEDICATED RECEPTACLE FLUSH MTD FLOOR RECEPTACLE TELEPHONE OUTLET JUNCTION BOX 24HR 7 DAY -TIME CLOCK DISCONNECT SWITCH TEL EPHONE BOARD ELECTRICAL PANEL 3 #I2, I /2 "G (2 GKT WIRES AND I NEUTRAL) HOME RUN CONDUIT STUBBED UP CONDUIT STUBBED DOWN GROUND FAULT INTERRUPTER NIGHT LIGHT TIMEGLOGK CONTRACTORS NOTE UPON RECEIVING FIXTURES FROM ONG, THE E.G. SHALL IMMEDIATELY NOTIFY GNG OF ANY ADDITIONAL LIGHTING FIXTURES AS REQUIRED BY THE LIGHTING PLAN. ALL FIXTURES TO BE INSTALLED PRIOR TO FINAL INSPECTIONS. LIGHT FIXTURE SCHEDULE LAMP SCHEDULE SYMBOL TYPE DESCRIPTION MANUFACTURER CATALOG NO. VOLTS MOUNTING DESCRIPTION it of TOTAL LAMPS WATTS MEM MEM A 2 x 2 FLUORESCENT W/ a CELL PARABOLIC LENSES LIGHTOLIER DPA2GgL52FT (120/2T705) ADV RGN- 2TfP40 -SG 2L 120/2T1 REG FT40T5 /S35 5IAX 2 15 MUM ■ ■ ■ ■ ■■ MINIMUM AA 2 x 4 FLUORESCENT IN/ a CELL PARABOLIG LENSES LIGHTOLIER DPA2G171 5232 (120/2T105) ADV ING 2P325G GEN 2L 120/271 REG T8\321,1\855 2 5cf B 2 X 2 FLUORESCENT IN/ PRISMATIG AGRYLIG LENSE LIGHTOLIER SPS2GFSVA2FT (120/2T105) ADV RCH- 2T1P40 --SG 2L 120/211 REG FT40T5/835 BIAX 2 15 -■a BB 2 X 4 FLUORESGENT IN/ PRISMATIC ACRYLIC LENSE LIGHTOLIER SP52GFSVA232 (120/21105) ADV ING 2P325G GEN 2L 120/211 REG T8/32W/835 2 0 G RECESSED 6" OPEN DOWNLIGHT PAR INN/ FRAME KIT LIGHTOLIER G6l30DGLW/ G6120 120 REG PAR 30/151N/1-1IR SHORT NEGK 15 48" TWO LAMP OPEN STRIP LIGHT LIGHTOLIER S1N45232HPFUNVGA ADV INC 2P325G GEN 2L 120/211 SUR TS/521/855 2 64 l ►� E= '1^IALMASTER' 2' WALLINASHER LIGHTOLIER WMRLI24120CD ADV RCN- ITTP4O -SG IL 120/211 REG FT4ODL /835/x5 40 I_ 1 EE 'WALMASTER' 4' WALL.WASHER LIGHTOLIER WMRL2441205B GONG 120/211 REG FT40DL /835/x5 2 80 0 F SINGLE GERAMIG METAL HALIDE WALL WASHER LIGHTOLIER 83W1UWH\ 83B105EWH 120 PEN/TRK EDI1P /GMH/MED/30K 10 G SINGLE CERAMIC METAL HALIDE ENCLOSED SPOT LIGHTOLIER 8311U1NH\831310 SEfr'JH /83ED Itf5/ AL4HG 120 PETVIRK EDI1P /GMH/MED/30K 10 u 0 0 H 26" - 2 LAMP BIAX TRAC HEAD LIGHTOLIER 521cfENINH. 120 PEN/TRK P T4ODL /835/RS 2 80 J GIMBOL RING TRACK HEAD LIGHTOLIER g023WH 120 PEN/TRK 15 PAR 30 /GAP/ SPL/MFL25 75 0 K GALGULITE INCANDESCENT ADJUSTABLE ACCENT LIGHTOLIER AA1CLII30/ PAA1P5BD 120/211 REG PAR38/151WI -fIR 15 T2 24" ONE GIRGUIT, SURFACE TRAG WHITE, 11/60841 GLG CLIP LIGHTOLIER 6000WH 120 SUR NOT APPLIGABLE 11 T4 48" ONE GIRGUIT, SURFACE TRAG WHITE, IN/608g GLG CLIP LIGHTOLIER 6001 WH 120 SUR NOT APPLICABLE TS G6" ONE GIRGUIT, SURFAGE TRAG WHITE, IN/608q GLG CLIP LIGHTOLIER 6002K -f 120 SUR NOT APPLICABLE EM -I L.E.D. EXIT SIGN DUALITE 120/211 SUR INCLUDED 3 EM -2 EM -3 LED. 'EXIT' SIGN IN/ DUAL EMERGENCY LIGHTS, - GIOMIN. BATTERY BAGKUP DUAL EMERGENCY LIGHTS, - gOMIN. BATTERY BACKUP DUALITE DUALITE LIURW EZ -2 120/211 120/211 SUR SUR INGLUDE D INCLUDED 2 2 5 5 z EXHAUST FAN/LIGHT COMBINATION NUTONE 8664RP 120 REG 601N AID{ 155 PANEL No. D DOUBLE= I I LOCATION MAIN IDOA MAIN LUG E ENCLOSURE SERVICE ❑ phase 4 w►re p wire c circ s p5 p pole F FOR p phase load F FOR n noc a anps p pole S Size A 5 5 G G p #& 1 1 S SO A AIR HANDLING UNIT < 4 4000 C CONDENSING UNIT 2 2 3 35 # #g 2400 4 #a �� 11 11 2 4000 1 11 11 4 4 2 #8 3 3 � 2100 #12 5 5 2 20 1 1 S SIGN 1 1200 T TRACK LIGHTS 6 6 2 20 1 1 * *12 400 #I2 1 1 2 20 1 1 S SALES LIGHTS I TELEPHONE BOARD 8 8 2 20 1 1 # #12 ISO T #I2 q q 2 20 1 1 S SALES LIGHTS 3 300 S STOREFRONT LIGHTS 1 10 2 20 1 1 # #12 1210 I. PROVIDE A TYPED INDEX GARD IDENTIFYING ALL CIRCUITS. 2. ALL BREAKERS ARE EXISTING TO REMAIN. LOGK -ON BREAKER DEDICATED GIRGUIT W/ ISOLATED GROUND RUN GIRGUIT THRU TIMEGLOGK EXISTING GIRGUIT BREAKER TO REMAIN PROVIDE NEW BREAKER RE -USE EXISTING BREAKER FOR NEW GIRGUIT SHOWN RE -WIRE EXISTING GIRGUIT TO NEW BREAKER, TO BALANCE LOAD • 0 0 0000 0 EXISTING LANDLORD'S SERVICE ENTRANCE TO REMAIN. EXISTING IOOA/3P FUSED IOOA. DISCONNECT TO REMAIN. E.G. SHALL COORDINATE METER W/ LOGAL POWER COMPANY. EXISTING 4 #2 THAI, I #S OND., 2" G. TO REMAIN. PANEL HP" EXISTING -7 DAY, 24 -HR TIMEGLOGK TO REMAIN. FIELD VERIFY. EXISTING PANEL "P" 100 A. MAIN LUG ONLY 120/20S V. 3 PHASE, 4 W. 18 SPACES EIACT IC41_ RiSER D1,4GR4M 6EWP�p,NCE CODE A - NEC NF APR 2. a no " Ciiy fl� Tukwila BUILDING DM . ION NOTE : THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. 9 RECEIVEr APR 22 20 PERMIT CENTEI ac 0 0 U-. CO H 0- Q 0 0 o) z LX 0 -_1 z 1 0 lrl z_ DESCRIPTION w H O V) Q 7 w �OmyO - --- -I 00 Q Q W W 2 co Wz< ZU� Lai U �Q0 (i'o- TkD� I- V) Y III O a Store No. 5288 Drawn by: MWS Date: 6/7/2007 Checked By: RR Drawing Name: 05288. DWG Date: DATE CHECKED Drawing No. 2 1 ELECTR I GAL SPEC 1 F 1 GAT I ON5 I. DEMOLITION NOTES A ELECTRICAL DEMOLITION WORK SHALL INCLUDE, BUT SHALL NOT BE LIMITED TO, REMOVING LIGHTING PANELS, LIGHTING FIXTURES, RECEPTACLES, WIRE, CONDUIT, ETG, AS REQUIRED FOR THE INSTALLATION OF NEW EQUIPMENT AS INDICATED ON DRAWINGS. B. CONTRACTOR SHALL REMOVE ANY EXPOSED WIRE, CONDUIT, HANGERS, CLAMPS, ETC., WEIGH ARE NOT BEING UTILIZED FOR THE NEW INSTALLATION. G. EXISTING WIRE AND CONDUITS CONGEAL Et ABOVE CEILING OR IN WALLS NOT BEING REUSED SHALL BE REMOVED. EXISTING CONDUITS, MERE APPLICABLE, MAY BE REUSED. D. PROVIDE A NEW TYPEWRITTEN CIRCUIT DIRECTORY FOR EACH NEW OR EXISTING PANEL. E. CONTRACTOR SHALL VISIT THE JOB SITE AND BE THOROUGHLY AWARE OF EXISTING CONDITIONS UNDER WHICH THE WORK MUST BE PERFORMED AND SHOULD ADVISE GNG CONSTRUCTION DEPARTMENT OF ANY INTER.FEIRENCES OR VIOLATIONS BEFORE SUBMITTING THE BID. F. ALL EXISTING EQUIPMENT NOT UTILIZED AS PART OF THE NEW WORK SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND BE DISPOSED OF AWAY FROM THE JOB SITE. G. EXISTING METERING IS TO REMAIN. FIELD VERIFY EXISTING CONDITIONS AND REQUIREMENTS. 2. GENERAL A. ALL SUB TRADES SHALL COORDINATE THEIR WORK 111TH WORK OF OTHERS OR WITH EXISTING CONDITIONS OGGURRING ABOVE OR BELOW THE LEASED PREMISES AND SHALL MAKE CHANGES FROM TIME TO TIME AS REQUIRED TO AGGOMMOPATE SUGH WORK OR GONDITIONS. B. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF ALL FEDERAL, STATE, AND LOCAL LAWS, ORDINANCES, AND REGULATIONS AS WELL AS THE RULES AND STANDARDS OF THE NATIONAL BOARD OF FIRE UNDERWRITERS, THE NATIONAL ELECTRICAL GORE, THE NEMA, AIEE, AND OSHA. G. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND CERTIFICATES OF INSPECTION FOR WORK HEREIN SPECIFIED. THE COST OF SUCH PERMITS AND CERTIFICATES SHALL BE INCLUDED IN THE BID PROPOSAL. D. ELECTRICAL CONTRACTOR SHALL VI51T YFE SITE AND BUILDING AND SHALL EXAMINE TO HIS/HER SATISFACTION ALL OF THE PHYSICAL CONDITIONS THAT AFFECT THE CONTRACT PRICE, NOTING THE LOCATION OF EXISTING EQUIPMENT. NO ADDITIONS TO THE CONTRACT PRICE WILL BE PERMITTED DUE TO IGNORANCE OF EXISTING CONDITIONS. E. ELECTRICAL CONTRACTOR SHALL WIRE COMPLETE ALL NEW SERVICE SWITCHES, EQUIPMENT PANELS, SWITCHES, LIGHT FIXTURES, DUPLEX OUTLETS, ETG., AS REQUIRED AND AS SHONI■L ALL NEN BRANCH CIRCUIT WIRING AT LIGHT PANEL, DISCONNEGT5, ETG., SHALL BE AS INDICATED OR AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. F. SHOULD ANY QUESTIONS ARISE REGARDING OUTLET LOCATION, ACCESS POOR REQUIREMENTS, ETG., GONTAGT GNG CONSTRUCTION DEPARTMENT. G. IN GENERAL, WIRES SHALL BE RUN IN CORROSION RESISTANT, THREADED INTERMEDIATE METAL CONDUIT (I.M.G), OR ELECTRICAL METALLIC, TUBING (E.M.T), OR PRE - WIRED FLEXIBLE CONDUIT (REFER TO NEC ARTICLE 333), UNLESS OTHERWISE NOTED. H. PROVIDE 'TEFLON" COATED WIRE, OR MINA/ALL E.M.T. CONDUIT SYSTEM FOR LOW VOLTAGE SYSTEMS. I. BRANCH GIRGUIT WIRING IN CONCRETE OR MASONRY OR DAMP LOCATIONS SHALL BE RUN IN INTERMEDIATE METAL CONDUIT (NEC ARTICLE 345) USING "THEN" WIRE J. THE FINAL CONNECTION AT ALL MOTORS OR MOTORIZED EQUIPMENT SHALL BE MADE WITH A MINIMUM OF 12' OF LIQUID TIGHT FLEXIBLE CONDUIT WITH APPROVED GROUNDING MEANS. CONDUIT AND FITTING SHALL CONFORM TO THE FOLLOWING: STEEL CONDUIT, ELBOWS, AND COUPLINGS SHALL BE HOT DIPPED GALVANIZED, GONFORM TO THE LATEST (ANSI) SPECIFICATION FOR STEEL CONDUIT, ZING COATED, AND SHALL BE PITTSBURGH, REPUBLIC, TRIANGLE, YOUNGTOWN, OR APPROVED EQUAL. K BOXES AND FITTINGS SHALL BE STEEL CITY, APPLETON ELECTRIC, RAGO, OR RUSSELL AND STOLL, GALVANIZED STEEL, COPE THICKNESS, A MINIMUM OF I -I/2" DEEP, AND OF SUFFICIENT SIZE TO AGGOMMOPATE THE DEVIGES SHOWN ACCORDING TO NEC, REQUIREMENTS. L. ALL EQUIPMENT, NEW OR EXISTING, INSTALLED ABOVE A CEILING USED AS A PLENUM FOR ENVIRONMENTAL AIR SHALL BE 50 RATED FOR THAT PURPOSE. NO OPEN CABLING OR PVG PLASTIC, CONDUITS SHALL BE INSTALLED IN THE PLENUM SPACE AS NOTED IN NEC #300- 22. M. WIRE AND GABLE SHALL BE OF COPPER WITH CIS% CONDUCTIVITY AND SHALL MEET THE STANDARD SPECIFICATIONS AND TESTS ESTABLISHED FOR SUCH MATERIALS AND GONSTRUGTION OF ASTM, NEMA, UL ANSI, AEIG, AND IPEGA, WEERE APPLICABLE MATERIAL CONSTRUCTION DATA, INSULATION THICKNESS, JACKET THICKNESS TEST DATA, AND SAMPLE SHALL BE SUBMITTED FOR APPROVAL UPON REQUEST. WIRE AND GABLE SHALL BE AS MANUFACTURED BY ANAGONDA, AMERICAN STEEL AND WIRE, GENERAL GABLE, GENERAL ELECTRIC, OKONITE, PHELPS DODGE, REYNOLDS, SIMPLEX, TRIANGLE, OR APPROVED EQUAL. I. WIRE FOR GEMERAL INTERIOR BRANCH CIRCUIT USE ( #S MG AND SMALLER) SHALL BE TINNED, STRANDED, ANNEALED COPPER. INSULATION SHALL BE A MOISTURE AND HEAT RESISTING THERMOPLASTIC MEETING UL REQUIREMENTS FOR TYPE "THHN/THWN', 600 VOLT, 90 DEGREES G. 2. WIRE FOR FEEDERS AND POWER EQUIPMENT (#6 AW5 AND LARGER) SHALL BE STRANDED COPPER: INSULATION SHALL BE A MOISTURE AND HEAT RESISTANT GROSS- LINKED SYNTHETIG POLYMER, MEETING THE IJL REQUIREMENTS FOR TYPE "XHHW°, 600 VOLT, GO DEGREES G (DRY LOCATIONS). 3. TRANSFORMERS A. STEP DOWN TRANSFORMERS SHALL BE EQUAL TO GE OR NITSTINGHOUSE 600 VOLT GLASS "DRY TYPE' SINGLE OR THREE PHASE (PER PLAN) GLASS 'R' INSULATION WITH MULTIPLE TAPS ABOVE AND BELOW RATED VOLTAGE. 4. PANELS AND OVERGURRENT PROTEGTION A. LIGHTING AND RECEPTACLE PANELBOARDS SHALL BE CIRCUIT BREAKER TYPE WITH THERMAL MAGNETIC, TRIP FREE, TRIP INDICATING, INVERSE TIME. MULTIPLE POLE BREAKERS SHALL BE GOMMON TRIP CIRCUIT BREAKERS, EQUIPPED WITH SILVER ALLOY CONTACTS AND QUICK -MAKE, QUICK -BREAK MECHANISM, AND WITH INSULATED SCREW TERMINAL SOLID NEUTRAL BAR PANELS TO HAVE MAIN BREAKERS OR MAIN LUGS ONLY AS NOTED. I. LIGHTING AND RECEPTACLE PANELS SHALL BE FLAT FRONT AND TRIM UNITS EQUIPPED WITH CONGEALED HINGED DOOR AND 7YPEWRIITEN CIRCUIT DIRECTORIES. B. ALL ELECTRICAL 11OIRK IN THE DEMISED PREMISES, UNLESS OTHERWISE NOTED, INCLUDING, BUT NOT LIMITED TO, ALL LIGHTING FIXTURES, SHALL BE OF A MANUFACTURER APPROVED BY GNG CONSTRUCTION DEPARTMENT'S PROVISIONS AND INSTALLATION OF ELECTRICAL PANELS, BREAKERS, WALL OUTLETS, BOXES, POWER SYSTEM FEEDERS, EMPTY CONDUIT FOR COMMUNICATION SYSTEMS WIRING, AND INSULATION OF LIGHTING FIXTURES SHALL BE BY THE ELECTRICAL GONTRAGTOR. CONSULT PLANS AND DETAILS FOR EXTENT OF WORK ALL ELECTRICAL MATERIALS SHALL BE NEW AND SHALL BE NATIONAL ELECTRIC CODE STANDARD, UNLESS BEI IL-R. GRADE 15 MENTIONED HEREIN, AND SHALL BEAR THE UNDERNIRITERS' LABORITORIES LABEL. G. ELECTRICAL CONTRACTOR SHALL GUARANTEE AGAINST MECHANICAL AND ELECTRICAL DEFEGTS OF ANY OR ALL EQUIPMENT, MATERIALS AND WORKMANSHIP COVERED BY THESE SPECIFICATIONS AND SHALL MAKE GOOD, REPAIR, OR REPLACE, AT HI5 OWN EXPENSE, ANY DEFECTIVE EQUIPMENT, MATERIAL, WORK OR PART WHICH MAY SHOW ITSELF WITHIN A PERIOD OF ONE (I) YEAR AFTER FINAL ACCEPTANCE OF WORK D. UPON COMPLETION OF ELECTRICAL WORK, THE INSTALLATION SHALL BE ENTIRELY FREE FROM GROUNDS AND SHORT CIRCUITS. ALL CIRCUITS SHALL BE GROUND OUT AND PROPERLY LASELEP. ALL CIRCUITS SHALL BE BALANCED ACROSS ALL PHASES IN ALL PANELS MEW AND /OR EXISTING) E. THE ELECTRICAL SYSTEM GROUNDING AND GROUNDING ON NON-CURRENT CARRYING METAL PARTS OF ELECTRICAL EQUIPMENT SHALL IN ALL INSTANCES GONFORM TO TFE MINIMUM REQUIREMENTS OF TFE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE WITH ADDITIONAL GROUNDING AS SHOWN ON THE DRAWINGS AND AS SPECIFIED HEREINAFTER. THE MINIMUM SIZE CONDUCTOR TO BE USED FOR ELECTRICAL SYSTEM GROUNDING SHALL BE NO. 6. WHERE CONDUIT 15 USED FOR MECHANICAL PROTECTION OF A GROUNDING CONDUCTOR, THE CONDUCTOR SHALL BE SECURELY BONDED TO THE CONDUIT AT EACH END. CONSULT DRAWINGS FOR EXALT SIZE OF GROUNDING CONDUCTORS AND /OR CONSULT MEG ARTICLE 250, TABLE 250 -c14 F. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL TEMPORARY LIGHTING AND RECEPTACLE5 AS REQUIRED TO MEET OSHA REQUIREMENTS. G. ALL CONTROL WIRING FOR HVAG SYSTEM SHALL BE BY THE HVAG CONTRACTOR H. LIGHTING AND RECEPTACLE PANELS SHALL BE RATED 1201208 VOLT, 3 PHASE, 4 WIRE, WITH MINIMUM RATED IOpoo A.I.G. BOLT -ON BREAKERS. PANELBOARD SHALL BE NOMINAL SIZE, 20' WIDE x 5-3/4' DEEP WITH LOCKING DOORS AND WITH BUSSING AS SIZED ON DRAWINGS, SIMILAR To SQUARE D, TYPE uNQOBU OR OTHER APPROVED. SAFETY SWITCHES SHALL BE FUSIBLE OR NON - FUSIBLE TYPE AS INDICATED ON PLANS. UNITS SHALL BE QUICK -MAKE, QUICK- BREAK, SAFETY INTERLOCK TYPE, SINGLE THROW, SINGLE, THO OR THREE POLE, 250 VOLT RATING AS REQUIRED, AND WITH AMPERE AND /OR HORSE'O1^1152 RATING INDICATED OR REQUIRED FOR THE INSTALLATION AND AS SHOWN ON DRAWINGS. IF CIRCUIT BREAKERS ARE TO BE USED AS THE SWITCH CONTROL OF LIGHTING CIRCUITS, THE BREAKERS MUST BE APPROVED FOR THAT USE (TYPE 'Skip'). . PROVIDE GFI BREAKERS AS NOTED AND AS REQUIRED. . PROVIDE GROUND BUS AS INDICATED IN PANEL SCHEDULE AND /OR RISER DIAGRAMS. IN GENERAL, ENCLOSURES SHALL BE NEMA I EXCEPT WHERE Y EATHIERPRO' OF SWITCH 15 REQUIRED. ENCLOSURES SHALL BE NEMA 3R. . UNITS SHALL BE "GOAL DUTY" TYPE AND SHALL BE SIMILAR TO SQUARE D TYPE "GD" OR OTHER APPROVED. I. TV= FOR THIS PROJECT SHALL BE AS MANUFACTURED BY BU55MAN MANUFACTURING CO., CHASE-GOULD GO., OR RELIANCE FUSE, AND SHALL BE OF THE SIZE AS INDICATED ON THE DRAWINGS OR AS REQUIRED. COORDINATION AND VERIFICATION OF FINAL SIZING AND INTERRUPTING CAPACITY OF FUSES SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AT THE COMPLETION OF THE PROJEGT. ALL FUSES FOR THIS PROJECT SHALL BE PROVIDED BY THE CONTRACTOR AND SHALL BE OF ONE MANUFACTURER I. FUSES FOR PROTECTION OF ALL MOTOR GIRGUITS SHALL BE DUAL ELEMENT, TIME DELAY TYPE, 'LOW PEAK ". 2. FUSES FOR PROTECTION OF CIRCUIT BREAKERS SHALL BE FAST ACTING "LIMITRONS '. 3. FUSES FOR PROTECTION OF EQUIPMENT OTHER THAN THOSE LISTED ABOVE SHALL BE °FUSE - RONS' 5. ELECTRICAL DEVICES A. LOCAL WALL SWITCHES SHALL BE SPECIFICATION GRADE, 20 AMP, 120/211 VOLT, RATED NON- MERGURY "QUII=1 It' TOGGLE SWITCHES WITH MITE OPERATING HANDLES. SWITCHES SHALL BE HUBBELL #1221 SERIES, ARROW -FART, BRYANT, GENERAL ELECTRIC, OR P 4 5 FOR OPERATING ON 120V CIRCUITS. SWITCHES SHALL BE MOUNTED 4' -0" ABOVE THE FLOOR. B. GENERAL USE RECEPTACLES SHALL BE DUPLEX, 2 WIRE, 3 POLE, SELF - GROUNDING TYPE 111TH STANDARD PARALLEL SLOTS TO ACCOMMODATE BOTH REGULAR AND GROUND TYPE PLUG GAPS. RECEPTACLES SHALL BE, 20A, AND BEAR UL LABELS FOR RATINGS AT 125V AG. RECEPTACLES SHALL BE HUBBELL #5362 SERIES, A.14. * 14., BRYANT, Pit 5, OR GENERAL ELECTRIC. G. FLUSH FLOOR BOXES SHALL BE GAST IRON, WATERTIGHT, AND FULLY OR SEMI - ADJUSTABLE AS REQUIRED. FLOOR BOXES INSTALLED IN FLOORS NITHOLT ROUGH SLAB AND TOPPING SHALL BE SINGLE GANG AND SIMILAR TO HUBBELL #B -2431 OR HUBBELL #13-2414 (- MI- ADJUSTABLE) FOR INSTALLATIONS WITH EXISTING ROUGH SLAB WITH NEW 2" TOPPING. DOVER PLATE SHALL BE HUBBELL 45 -3825 DUPLEX COVER FLAP FOR POKER AND HUBBELL #16.5362 ISOLATED GROUND DUPLEX RECEPTACLE. PROVIDE CARPET FLANGES AS REQUIRED. D. ELECTRICAL FLOOR OUTLETS SHALL BE FLUSH POKE -THRU TYPE WITH FULL CAPACITY FOR TWO SERVICES; 5 OR 20 AMP RECEPTACLE POWER; 111TH INDIVIDUAL OPENINGS FOR LOW TENSION WIRING -- DUPLEX RECEPTACLE TO BE 5262, AND SHALL EXCEED FEDERAL SPECIFICATIONS 110546E; COMPATIBLE WITH ANY THICKNESS SLAB. E. ALL SWITCHES, REGEPTACLE AND TELEPHONE PLATES, ESCUTCHEONS, ETC., FOR ALL CONGEALED CONDUIT AREAS SHALL BE FLAT FRONT, SMOOTH EDGES, ROUNDED CORNERS, STEEL PLATES, SMOOTH FINISH, FINISH AS FOLLOWS: WHITE PLATES ON WHITE FINISHES; BLACK PLATES ON BLACK FINISHES; ALL OTHER PLATES SHALL BE IVORY. PLATES SHALL BE SIMILAR TO HIBBELL "THERMOPLASTIC" OR OTHER APPROVED. ALL DEVICE PLATES FOR EXPOSED BOXES SHALL BE CADMIUM OR ZING PLATED STEEL. F. DOVER PLATES AND RECEPTACLES FOR EXTERIOR OUTLETS (HEATHERPROOF TYPE) SHALL BE MOUNTED HORIZONTALLY WITH DOUBLE LIFT COVERS AND GAST ALUMINUM. BOX AND COVER PLATES SHALL BE SIMILAR TO HUBBELL #5200 SERIES OR OTHER APPROVED. ALL EXTERIOR REGEPTAGLES SHALL BE GFI GIRGUIT PROTECTED. G. DIMENSION NEXT TO OUTLETS: INDICATE ABOVE FINISHED FLOOR ELEVATION TO CENTER OF JUNCTION BOX. H. TIME CLOCKS (SWITCHES) FOR CONTROL OF SIGNS SHALL BE SYNCHRONOUS MOTOR TYPE, MANUAL OVERRIDE SWITCH, DAY SKIPPER, AND 24 HOUR DIAL. INTERMATIG #T -I1O SERIES OR OTHER APPROVED. 6. LIGHTING A. LIGHTING FIXTURES SHALL BE UL LISTED, COMPLETE IN EVERY DETAIL, INCLUDING PLASTER FRAMES WHERE REQUIRED, PROPERLY WIRED AND CONNECTED WITH CONDUITS SUPPLYING SAME. ALL INDICATED AND HID FIXTURES SHALL BE PREWIRED. COORDINATE INSTALLATION OF FIXTURES WITH CEILING TYPE CONSTRUCTION AND GRID LAYOUT. I. LIGHTING FIXTURES SHALL BE SEGL ELY SUPPORTED AS REQUIRED. SUPPORTS SHALL BE BY THE ELECTRICAL CONTRACTOR SURFACE- MOUNTED OF SUSPENDED FLUORESCENT LIGHTING FIXTURES SHALL HAVE A MINIMUM OF TWO (2) SUPPORTS PER 4 FEET OF LENGTH. 2. EXIT LIGHTS SHALL NOT BE SUPPORTED FROM THE CEILING TILES. ALL RECESSED FLUORESCENT FIXTURES TO HAVE SAFETY GRID CLIPS AS REQUIRED BY NEC. 2002 ARTICLE 410 -16, PARAGRAPH (G). 3. ALL LIGHTING FIXTURES SHALL BE PANEL SNITCHED UNLESS OTHERWISE INDICATED ON THE PLANS OR DETAILS. 4. LIGHTING FIXTURE CHANNELS SHALL NOT BE UTILIZED AS A WIRING RAGENAY UNLESS CHANNELS ARE PROVIDED AND LABELED FOR SUCH USE BY IJL AND AS APPROVED BY NEC. 5. IN GENERAL, ALL RECESSED FIXTURES SHALL COMPLY WITH ARTICLES #410 -64, #410 -66, #410 -68, AND #410 -13 OF NEG REGARDING TEMPERATURE, CLEARANCE, CONSTRUCTION, AND INSULATION. 6. ELECTRICAL CONTRACTOR SHALL UPDATE EXISTING AND /OR INSTALL NEW NIGHT LIGHT CIRCUITS, EXIT LIGHTS, AND EMERGENCY LIGHTING AS REQUIRED TO COMPLY WITH THE REQUIREMENTS OF STATE AND LOCAL CORES AND AUTHORITIES. 1. VERIFY "LETTER DOLOR ", STYLE, SIZE AND SPACING OF EXIT LIGHTS WITH LOCAL GORES PRIOR TO INSTALLATION. 8. AT THE COMPLETION OF WORK, ALL FIXTURES SHALL BE GLEAN AND FREE OF FOREIGN MATERIALS AND DEBRIS. REPLACE ALL BURNED OUT OR DEFECTIVE LAMPS, BALLASTS, FUSES, LENSES, ETC,. 1. TELEPHONE A. ELECTRICAL CONTRACTOR TO SUPPLY ALL WIRE CONNECTIONS FOR TELEPHONE SERVICE AND RUN ALL HIRES FROM 510-NUTRITIONAL ENCYCLOPEDIA (BNE) AND GASHWRAP TO THE PHONE BLOCK IN REAR OF STORE. SEE SHEET E -3. 8. ELECTRIC GASH REGISTER A. ELECTRICAL CONTRACTOR TO INSTALL JUNGTION BOX WITH (I) 12OV, 20A, ISOLATED GROUND CIRCUIT FOR P05 (SEPARATE CIRCUIT) AND (I) 120V, 20A, CIRCUIT FOR CONVENIENCE OUTLET FOR GENERAL USE, MOUNTED AT COWER AS SHORN!. B. THE GIRCUIT USED TO POWER AN P05 GASH REGISTER SHALL NOT BE USED FOR OTHER ELEGTRO- MEGHANIGAL EQUIPMENT. THE GIRGUITS SHALL NOT SHARE THE NEUTRAL LINE WITH OTHER EQUIPMENT, SEPARATE POWER, NBJTRAL AND GROUND HIRE-5. WIRE SIZE SHALL BE #I2 MG AND SHALL BE RUN TO CIRCUIT BREAKER BOX WI1H GROUND WIRE TIED TO GROUND TERMINAL IN PANEL. ISOLATED GROUND WIRE AND BUS FROM NEUTRAL. DO NOT USE 11415 CONDUIT FOR GROUNDING AS THESE GROUNDS MAY NOT BE ADEQUATE AT THE HIGH FREQUENCIES UTILIZED BY THE ELECTRIC GASH REGISTER THE POKIER LINES FOR THE ELECTRIC GASH REGISTERS SHOULD NOT BE RUN IN THE SAME CONDUIT AS IT EE POWER LINES FOR HEAVY MOTOR LOADS. q. FIRE AND SMOKE DETECTION SYSTEM A. IF REQUIRED BY THE LANDLORD OR LOCAL BUILDING GODES, THIS CONTRACTOR SHALL COORDINATE WITH THE MECHANNIGAL CONTRACOTR TO FURNISH AND INSTALL A FIRE AND SMOKE DETECTIONS SYSTEM, INCLUDING BUT NOT LIMITED TO, SMOKE DETECTORS, SMOKE EXHAUST FANS, VISUAL AND AUDIBLE ALARMS, TAMPER AND FLOW SNITCHES, Eft. Al EQUIPMENT MUST BE FULLY OPERABLE AND MEET THE LANDLORD AND BUILDING DEPARTMENT REQUIREMENTS. GONTAGT THE TENANT'S REPRESENTATIVE WITH ANY DISCREPANCIES OR MISUNDERSTANDINGS. RECEIVEi APR 2 2 20 PERMIT CENTS 1; t�0 o� f Ci)000 HQ%)(1) <doIN 0 X -I 1 000 owe' x_w e- Z zo v "NQ= REGISTERED ARCHI" GREG T STATE OF 0 0 I • LL 0_ o/ Q o • z c O 0 lri � O z Z D CO DESCRIPTION 1- O a3 1-- O w J J DO a Q 00 2 co f Wz< U W U� W 0 CO / �JO 0 r U or- DQ cn can' Store No. 5288 Drawn by: MWS Checked By: RR Date: 6/7/2007 Date: DATE CHECKED Drawing Name: 05288. DWG Drawing No. E -3