Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0461 - WESTFIELD SOUTHCENTER MALL - BOUTIQUE VIVID
WESTFIELD 2887 SC MALL 07 -23 -08 ELO8-46 1 CitiPof Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2887 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -461 Issue Date: 05/19/2008 Permit Expires On: 12/17/2008 Tenant: Name: BOUTIQUE VIVID Address: 2887 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 - 713 -4076 Address: 1725 WESTLAKE AVE N STE 210 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: NEW SERVICE, PANELS AND CIRCUITS Value of Electrical: $25,000.00 Fees Collected: $673.00 Type of Fire Protection: SPRINKLERS/AFA National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature:, 1 Date: OR-1« la I hereby certify that I have read and�x�ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be compliecd� whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or he performance of wor . I am authorized to sign and obtain this electrical permit. Signature: Print Name: liU C trUk \l,\J cu J Date: Orl (15�0� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -461 Printed: 07 -15 -2008 Cit3 of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 2887 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -461 Issue Date: 05/19/2008 Permit Expires On: 11/15/2008 Tenant: Name: WESTFIELD VANILLA BOX Address: 2887 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 - 713 -4076 Address: 1725 WESTLAKE AVE N STE 210 , SEATTLE WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: NEW SERVICE, PANELS AND CIRCUITS Value of Electrical: $25,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: 4,46(iU Fees Collected: National Electrical Code Edition: $615.00 2005 Date: Ccir(2 I hereby certify that I have read and ami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ith, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this electrical permit. i Signature: Print Name: L - :?v'tiry'l "'--)c Jul Date: 51 ( 10 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -461 Printed: 05 -19 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 2887 SOUTHCENTER MALL TUKW Suite No: Tenant: WESTFIELD VANILLA BOX Permit Number: EL08 -461 Status: APPROVED Applied Date: 04/24/2008 Issue Date: 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: 2 «J� Print Name: \E-CIVVIX—, W a Date: -61 19 I O doc: Cond -Elec EL08 -461 Printed: 05-19 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print* * 1E LOCATI /J n King Co Assessor's Tax No.: 4''34.42D -Dojo Site Address: e 7 So ��k� // .4J/ i�/1t` / t Suite Number: �� Floor: oZND ❑ Tenant Name: Property Owners Name: Mailing Address: New Tenant: Yes ..No City tate Zip E; Name: ►A I'll 14 ;..� �I/l�lTIMINIS' en yo r p rmit is ready to be assn � Eh Mailing Address: E -Mail Address: Day elephone: City Fax Number: 216 ELECTRIC C INFORMATIG Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ /, "6 /i7 D//''/ Scope of Work (please provide det led information): :tit Svc' v /' , /4/414 41 oitGvl j"f Will service be altered? Type of Use: Yes ❑ No Adding more than 50 amps? Yes ❑ No Type of work: New ❑ Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Pro a Served b : Puget Sound Energy ❑ Seattle City Light HA Applications On Iine4-2007 - Electrical Permit Application.doc bh Page 1 oft RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea .PER1VIIT�APPLICATION'NO Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: Mailing Address: Day Telephone: IDate Application Accepted: 1 1 f rj Date Application Expires: t 0 „D.., m Staff Initials: VvI H:Wpplications\Fonns- Applications On I.ine\4 -2007 - Electrical Permit Application.doc bh Page 2 of 2 1 • City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http: / /www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R08 -01707 Initials: JEM Payment Date: 05/19/2008 User ID: 1165 Payee: SME, INC. OF SEATTLE Total Payment: 4,752.00 SET ID: 0519 SET NAME: WESTFIELD VANILLA BOXES SET TRANSACTIONS: Set Member Amount EL08 -353 492.00 EL08 -460 852.00 EL08=4°6.1 852.00 E08 =1'62 852.00 EL08 -463 852.00 EL08 -466 852.00 TOTAL: 4,752.00 TRANSACTION LIST: Type Method Description Amount Payment Check 21106 4,752.00 TOTAL: 4,752.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 2,952.00 000.345.832.00.0 1,800.00 TOTAL: 4,752.00 2593 05/19 9711 TOTAL 4752.00 0 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http.• / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -461 Address: 2887 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/24/2008 Applicant: WESTFIELD VANILLA BOX Issue Date: Receipt No.: R08 -01305 Payment Amount: $123.00 Initials: WER Payment Date: 04/24/2008 11:03 AM User ID: 1655 Balance: $492.00 Payee: WESTFIELD TRANSACTION LIST: Type Method Descriptio Amount Payment Check 06012498 123.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 123.00 Total: $123.00 1610 04/24 9711 TOTAL 1160.45 doc: Receiot -06 Printed: 04 -24 -2008 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit _a01-1-10 PERMIT NO. �( J1 (206)431 -3 7 Project: O\ t.((�I DOTI Type of Inspection: 2f QQ `. Address: an ti Y v Date Called: Special Instructions: Date Wanted: 7 /Z� // ar. Requester: Phone No: 16 Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: Inspector: &Ado\ (Date: °*3 /o ri $60.00 REINSPECTION FEE PEECIUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit kz-C F(- Y6/ PERMIT NO. CITY OF TUKWILA BUILDING DIVISION V= 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3E7 Pr sect: 117 -16,/ VIVI Type of Inspectio �/G70 \.f Ads �C �4L� 7 Date Called: s tic r. L4 /'6'.. iM /FL Special Instructions: Date Wanted: a.m. p.m. Requester: r` 1.'r /Lau, z fa/- Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: /j? �)(2 /M4 L/1/ L / l ",N f /f ,Y //'R/4 YL-46E f$) / lcf C/» i:1 S f r/.' `4vv l.� 2)7X/44 7ii7 11.-7- f o r'T - s tic r. L4 /'6'.. iM /FL , ( fic / (N 7/111 - .VNE fi ()PA W& y &c /Y P %1- M 7 r` 1.'r /Lau, z fa/- VOl cd/ 2)4-79' C Inspe L 6174-14071/6 I7 Da,/;\0/6S $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. ti (206)431 -3670 Project: , 1 t1149 Type of Inspection: -7003 Address: Date Called: Special Instructions: Date Wanted: li am: Requester: Phone No: Approved per applicable codes. �COMMENTS: LJ Corrections required prior to approval. ' ° — ( I 4 CO J TVA W14 DVr — Ka thi, H IJ Inspector: Date: 0-1(1(0 pyit El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be frR paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Vohtik ex Type of Inspection: -7003 Address: 44 Date Called: Special Instructions: Date Wanted: cD / /2-0 a.m. p.m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: ?Pv covbik Lao 1.14-to 5ctirri4- I !Inspector: Date: %/2 0 '04 ❑ $60.00 REINSPECTION FEE R CURED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: - 2 INSPECTION RECORD Retain a copy with permitg- INSPECTION NO. PERMIT 1431 O. CITY OF TUKWILA BUILDING DIVISION 7.• 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: V. m4- Type of Inspection: 7005 Address: .2gyi 1 } Date Called: Special Instructions: Date Wanted: a p.m. Requester: Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: SA in/n�A. Aar gAc� �o� r�lgtc.- Date: o6 4-7/doe El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Inspector: „1:ethiAkk Receipt No.: (Date: b 6.4.414 . aa•: last' ...4 „_ a �'7Cr •..t_e_. w INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT NO. (206)431 -3670 Project: /PM A A iegY Type of Inspection: 700-7, ddress: ,W7 c a�J�� !,� Date Called: Special Instructions: ns: Date Wanted: /% �.ry m. Requester: Phone No: roved per applicable codes. El Corrections required prior to approval. MMENTS: f Inspes,3'�f/ :rf 67-446A/6 1/ Date 6.73/r 0 $58.00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: ti INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Cu g PERMIT NO. (206)431 -3670 Project: f f 1.� kJ 1 Type of Inspection: 70°3 Address: Z,gri 11 p F Date Called: Special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Pa C fdt AA LJA•14,5 Inspector: it 1 isrdi Date: 04- El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -02571 Initials: WER User ID: 1655 Payee: SME, INC. OF SEATTLE Payment Date: 07/15/2008 Total Payment: 362.00 SET ID: 0715 SET NAME: SME, INC SET TRANSACTIONS: Set Member Amount EL08 -460 58.00 NEM:870g 58.00 EL08 -632 246.00 TOTAL: 362.00 TRANSACTION LIST: Type Method Description Amount Payment Check 21182 362.00 TOTAL: 362.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 362.00 TOTAL: 362.00 4052 07/15 0711 TOTAL 362.00 2006 Washington State Nonresidential Energy Code Compliance Form L— Project Summary; 2006 Washington State Nonresidential Energy Code Compliance Forms PRJ -SUM Revised July 2007 Project Info Project Address 2887 Southcenter Mall Date 4/4/2008 Tukwila, WA 9e188 For Building Department Use Applicant Name: Keith Sxn th Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 r,- FILE- COPY PArmit No str REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAY 15 2008 City Of Tukwila BUILDING DIVISION ELO8'91 RECEIVED APR 242008 PERMIT CENTEF 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised Juy 2007 Project Info Project Address 2887 Southcenter Mall Date 4/4/2008 Tukwila, WA 98188 For Building Department Use 101 Applicant Name: Keith Smith Applicant Address: 1725 Westlake Ave. N, suite no Applicant Phone: Seattle, WA 98109 Project Description 2914.5 ❑ New Building ❑ Addition ' Alteration I Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2""' Area in ft2 Allowed x Area 101 Ll - CANOPY MTD. LINEAR FLUORESCENT retail 1.50 1943.0 2914.5 103 10 stock room 0.50 250.0 125.0 104 96.0 toilet 0.80 60.0 48.0 96.0 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3087.5 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 Ll - CANOPY MTD. LINEAR FLUORESCENT 18 96.0 1728.0 101 12 - RECESSED FLUORESCENT 10 26.0 260.0 103 Ll - CANOPY MTD. LINEAR FLUORESCENT 1 96.0 96.0 104 Li - CANOPY MTD. LINEAR FLUORESCENT 4 96.0 384.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2468.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (ba;ck) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Note: If occupancy type is "other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) L Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. hich ith 1 2 l reflector 1. Fluorescent fixtures which are non - lensed with a a) or two amps, b ) or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (VII /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums. banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations' 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail1D, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia ", assembly spaces" 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel/motel 1.0 Warehouses", storage areas 0.5 Hotel banquet/conference/exhibition hall" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified 'laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting Power Allowance Adjustments LTG; LPA 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 12887 Southcenter Mall 'Date 4/4/2008 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for in erior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor /room no.) Occupancy Description Allowed Watts per ft2'* Ceiling Height for this room Ceiling Height limit for this exception" Adjusted LPA Watts per ft2 101 SALES 1.50 12.0 feet 12 feet 1.50 103 STOCK ROOM 0.50 12.0 feet 12 feet 0.50 ■ ** From Table 15 -1 based on exceptions listed in footnotes 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, an;d Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 2887 3outhcenter Mail )Date 4/4/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local control/access Schedule with type, indicate locations E_1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations n. a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location yes (a) timer w/backup Indicate location E-1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E_1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 'Max. watts 'indicate watts for each exit sign 1 131 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yea I 1511 IElec motor efficiency'MECH -MOT or Equipment Schedule with hp, rpm, efficiency IM_2 1 TRANSFORMERS (Section 1540) yes I 1540 ITransformers 'Indicate size and efficiency 15-2 1 If "no" is circled for any question, provide explanation: , • 0 smith coo May 9, 2008 Jim Benner City of Tukwila Building Department Tukwila, WA Architecture 1 Design 1 Planning 1 Retail RE: CORRECTION LETTER #I Development Application Number EL08 -461 Westfield Vanilla Space — 2887 Southcenter Mall Dear Jim, Below is the responses to your correction letter dated April 29, 2008. 1. Emergency lighting to be on area lighting circuit per N.E.C. 700.12(F). a. Added to area circuit lighting, see Sheet E -I 2. Ensure 1 foot/candle of emergency lighting along entire path of egress measured at the floor. a. Added note and additional emergency lighting along path of egress, see sheet E- I 3. Note 11 on riser diagram should include #6 cu. ground per N.E.C. 250.122 a. Added note, see sheet E -2 4. Note 12 should include #4 cu. grounding electrode conductor to building steel per N.E.C. 250.66 a. ' Added note, see sheet E -2 5. Note 13 should read "(4) #3/0 cu." a. Added note, see sheet E -2 6. Loads on transformer, Panel B, branch circuits, and load summary are inconsistent. a. Revised load summary 1725 westlake avenue north suite 210 seattle. Washington 98109 206.838.5485 p 206.464.0700 f • 0 Page 2 May 9, 2008 7. RTU- I is 208 volt or 480 volt? a. Panel B denotes 3 pole 50 amp breaker (208 volt) i. Panel revised no rtu, FMP -I is 480v, see sheet E -2 b. Riser diagram (note 8) indicates 30 amp at 480 volt i. Corrected riser diagram note see sheet E -2 c. Power plan (note 4) indicates Panel H 1,3,5 VAV 3 pole 20 amp (480 volt) i. Revised note, see sheet e- I If you require any further information, please don't hesitate to phone me at (206) - 713 -4076. Regards, Keith L. Smith, AIA principal 1725 westlake avenue north suite 210 seattle, Washington 98109 206.838.5485 p 206.464.0700 f • April 30, 2008 • Cizy of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Keith Smith 1725 Westlake Avenue N, Suite 210 Seattle, WA 98109 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL08 -461 Westfield — Vanilla Box — 2887 Southcenter Mall Dear Mr. Smith, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Jim Benner, at 206 431 -3679, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Sincerely, 4/WAk t((°4A Brenda Holt Permit Coordinator encl xc: File No. EL08 -393 P:\Pennit Center \Correction Letters\2008\EL 08 -461 Correction Ltr #1.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Tukwila Building Division Jim Benner, Electrical Inspector Building Division Review Memo Date: April 29, 2008 Project Name: Westfield Vanilla Box Permit #: EL08- 461 Plan Review: Jim Benner, Electrical Inspector The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). Please include One Line Diagram, Load Summary, and Panel Directories (where applicable) 1. Emergency lighting to be on area lighting circuit per N.E.C. 700.12(F). 2. Ensure 1 foot/candle of emergency lighting along entire path of egress measured at the floor. 3. Note 11 on riser diagram should include #6 cu. ground per N.E.C. 250.122 4. Note 12 should include #4 cu. grounding electrode conductor to building steel per N.E.C. 250.66 5. Note 13 should read "(4) #3/0 cu." 6. Loads on transformer, Panel B, branch circuits, and load summary are inconsistent. 7. RTU -1 is 208 volt or 480 volt? a. Panel B denotes 3 pole 50 amp breaker (208 volt) b. Riser diagram (note 8) indicates 30 amp at 480 volt c. Power plan (note 4) indicates Panel H 1,3,5 VAV 3 pole 20 amp (480 volt) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. � PERMIT COORD COPV0 PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: EL08 -461 DATE: 07 -03 -08 PROJECT NAME: BOUTIQUE VIVID SITE ADDRESS: 2887 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # X Revision # 1 after Permit Issued DEPARTMENTS: / � O� 61GII�iing�ivision Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete Comments: DUE DATE: 07-08-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-5-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 etitRMIT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -461 DATE: 05 -09 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 2887 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTM N TS: Bu ng v on A Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATIQN OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-1 3-08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required ❑ No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06 -10-08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -461 DATE: 04 -24 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 2887 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bul Bing Won Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04-29 -08 Not Applicable U Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUESITHURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05 -27 -08 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) d Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: 440- 0& Departments issued corrections: Bldg fe Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/ outing sfp.doc 2 -28-02 PROJECT NAME: OW ktt / p SITE ADDRESS: MI AAA1A PERMIT NO:41 ORIGINAL ISSUE DATE: (� REVISION LOG t van REVISION NO. DATE RECEIVED I STAFF INITIALS ISSUED DATE STAFF INITIALS I o 1493{ o`li _ - 6 bl 15l Summary of Revision: 2Fsf L9 Uktt lki k wit fjp -N at t.),-/ Received by: Ltf elita (/A 14121 REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: - Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: %/3/x8' Plan Check/Permit Number: - L D ❑ Response to Incomplete Letter # -.. �FCEIVED ❑ Response to Correction Letter # r;;K;;•t�,y Er Revision # 1 after Permit is Issued JUL 0 3 2pd ❑ Revision requested by a City Building Inspector or Plans Examiner r;;-r•, Project Name: Bo ti Iii. v i' cry-12-2e,- /7 li,)es/- g e /�P Ii4 sue. %/- 'X) Project Address: —754- 7 sv u f rK /1 Contact Person: / r ---...4— / Y, car e4 Phone Number: 8 %8 - L — 2 Summary of Revision: r 7 l c-. P55 f4iZ (-2- X1`�/ r/'�'�j iNOY (� 4.) h-c- 41 t C7 e- P-r)/ 5' � 7/z, ,/^PJ Sheet Number(s): C l "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on 01-17701:11) lapplica ionslfonns- applications on Iinelrevision submittal Created: 8 -13 -2004 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan ChecWPermit Number: EL08' - ❑ Response to Incomplete Letter # [�] Response to Correction Letter # t ❑ Revision # after Permit is Issued RECEIVED c fry OF TI 11(WI A MAY 0 9 2008 ❑ Revision requested by a City Building Inspector or Plans Examiner JE .tMI 1 CENTER Project Name: 1/11e6714 e /d Van/14 &X Project Address: 28-87 W 4 / /1� Ti %l)1 LvA- 9'/s-i2 Contact Person: /%7,C' /i9 t 2)b,Gz"/?f) Phone Number: 2 ef-0 Z ^ 671 Summary of Revision: // / n Sec n ate- ra n1 Je ' - rev; 5j cfi 5 1 r? [ ec_ /-, �--.4.x Sheet Number(s): g ' / - Z "Cloud" or highlight all area of revision including date of revision Received at the City of Tukwila Permit Center by: /`�,��M PEntered in Permits Plus on lapplications\forms- applications on linelrevision submittal Created: 8 -13 -2004 Look Up a Contractor, Elect an or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SMEINS *066DB Licensee Name S M E INC OF SEATTLE Licensee Type ELECTRICAL CONTRACTOR UBI 601524252 Ind. Ins. Account Id Business Type CORPORATION Address 1 828 POPLAR PL S Address 2 City SEATTLE County KING State WA Zip 98144 Phone 2063292040 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/2/1994 Expiration Date 3/2/2010 Suspend Date Separation Date Parent Company Previous License Next License PACIFFS973PU Associated License BAKERJT973LR Master Electrician Information License BAKERJT973LR Name BAKER, JON T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MARVICH, STEPHEN E 01/01/1980 PINSKY, ADAM A 01/01/1980 BAKER, JON T AGENT 01/01/1980 • Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= SME1NS *066DB 05/19/2008 FLOOR PLAN NOTES BY SYMBOL O VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. V INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 LINE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD 15 IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF p"8 AWG THWN. O NOT USED LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL $ DESCRIPTION A COOPER/METALUX 2GA332A120VEB82 2'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING B LJTHONIA $W1 AZ INCANDESCENT RECESSED DOWNLIGHT, B" 60 WATTS C COOPER /METALUX GA232A120VEB81 1'x4' LAY -IN FLUORESCENT, TB ENERGY SAVING X1 DUAL -LIGHT LXURWELED UTEFORM COLLECTION EXIT LIGHTS/BA IILRY BACKUP X2 SURELITES CC7 EMERGENCY LIGHTING /BULBS INCLUDED 4 HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH, 20A 120 --277V -WHITE ASS HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY ps HUBBELL ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY +10' -0" AFF 36H COUNTER TABLE 2887 Southcenter Mall Tukwila, WA 98188 PROVIDE AND INSTALL NEW 30 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW FMB -1 UNI IN CEILING. VERIFY LOCATION IN FIELD. PROVIDE AND INSTALL NO � DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. PROVIDE AND INSTALL NEV' DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N..C. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ SEWED FOR E CEDE � Op NENG NFP JUL 11 2008 Cityef ION TukwilI B . TIDING D ION Consultant +10' -0° j LECTRICAL /POWE PLA + 14' -0" :FF NOTE: PROVIDE 1 FC OF EMERGENCY LIGHTING REQUIRED ALONG ENTIRE PATH OF ECRE•S- MEASURED AT FLOOR ISIONS shall be made to the scope work without prior app -oval of Tukwila Building Division. ROTE: Revisions will require a newlplan submittal Consultant Registration err' r-!-.1./ include additional plan review fees. FILE COPY Permit No. Par ravl9wopprovene rableot tO �authorize Approval of constrolion documents e violation of any adopted conditions Is egad: of appmed Copy and BY Date: City of Tukwila BUILDING DIVISION --H 6294 Architect Registration REGISTERED ARCHITECT '-- KEITH L SMITH STATE OF WASHINGTON Issues and Revisions No. Date Issues 1 03.31.08 15 2 05.08.08 3 06.28.08 By Check PERMIT KLS PERMIT CORRECTIONS KLS BY TENANT KLS ELCTRICAL/LIGHTI Project/Name WESTFIELD SOUTHCEN TER MALL 1 Pr4ct Number 02008018,00 Description POWER /LIGHTING PLAN Computer File CW05- 2008— E1,DWG Scale AS NOTED Template All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. FLOOR PLAN NOTES BY SYMBOL O VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. ® INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 IJNE GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM. OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THIN. O NOT USED ® PROVIDE AND INSTALL NEW 60 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. O PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. ✓ PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL # DESCRIPTION A COOPER/METALUX 2GA332A120VEB82 2'x4' LAY —IN FLUORESCENT, T8 ENERGY SAVING B LITHONIA 8W1AZ INCANDESCENT RECESSED DOWNLIG-{T, 8" 60 WATTS C 000PER /METALUX GA232A120VEB81 1'x4' LAY —IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL —LIGHT LXURWELED UTEFORM COLLECTION EXIT LIGHTS /BAIILRY BACKUP X2 SURELITES CC7 EMERGENCY LIGHTING /BULBS INCLUDED HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 - 277/ —WHITE oy7 HUBBELL ATP1277W PASSIVE INFRARED AND UTIUZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY ns� HUBBELL ATU1277RRW ULTRASONIC AND UIIIJZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY z r ® PROVIDE AND INSTALL NEW PANEL TO NEW FMB -1 UNI PROVIDE AND INSTALL NEV WATER HEATER ABOVE CEI PROVIDE AND INSTALL NE STOREFRONT SIGN PER N. 30 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM IN CEILJNC. VERIFY LOCATION IN FIELD. DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ING. VERIFY LOCATION IN FIELD. DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO .C. B B 30 ELECTRICAL /POWER PLAN SCALE: 1 /4" = 1' -0" SEPARATE REQUIRED �aR &MechW%ICJ ❑ Electrical ii lumbing jGas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the l scope of work without prior approval Tukwila Building Division, NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY ,. Permit Na, AI 2887 Southcenter Mall Tukwila, WA 98188 smith cc 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant PIalr review appal Is to errots n ansultan# Registration Approval of corspv n does not �e the violation of any adopted code or ordh ante. Receipt of approved Field Copy and ins is wed: By t� Date: L I D`b City of Tukwila BUILDING DIVISION Issues and Revisions No. Date 1 03.31.08 2 05.08.08 Architect Registration 6294 Issues By Check PERMIT KLS PERMIT CORRECTIONS KLS x '...,..... , t J .g! ■ ■ ■.� ELECTRICAL /LIGHTI SCALE: 1`4" - 1' -0" CORRECTION Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description POWER /LIGHTING PLAN Computer File CW05- 2008— E1.DWG oce`iVED CITY OF TUKWILA Scale AS NOTED MAY 0 9 2008 PERM` ` CENTER Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. E -1 \EW PA \EL B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X 1/20 12 100 EF1 2 2 3 3 SPACE — -- — X — -- — SPACE 4 1.2 3 5 SPACE -- -- — SPACE X — -- — SPACE 6 -- 3 7 SPACE -- — 9 X — -- — SPACE 8 — 3 9 SPACE -- — — X — -- — SPACE 10 — -- 11 WATER HEATER 750 12 2/20 GENERAL LIGHTING X — — — SPACE 12 — -- 13 750 X -- - — SPACE 14 1/20 2 15 SIGN 1200 12 1/20 X — -- — SPACE 16 1/20 17 SPACE — -- — X — -- — SPACE 18 19 SPACE -- -- — X — — — SPACE 20 21 SPACE — -- — X — -- — SPACE 22 23 SPACE — -- — X -- -- — SPACE 24 25 SPACE — -- — X — -- -- SPACE 26 27 SPACE — -- — X 1/20 12 360 GFI RECEPTACLES 28 29 SPACE — -- -- X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE — -- — X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE -- -- — X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE -- -- w X 1/20 12 1000 GENERAL RECEPTACLES 36 37 SPACE -- -- — X 1/20 12 1000 GENERAL RECEPTACLES 38 39 SPACE — -- — X 1/20 12 1000 GENERAL RECEPTACLES 40 41 SPACE — -- — X — -- — SPACE 42 REMARKS TOTAL LOAD PHASE 'A' 3560 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 3640 2- CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 3250 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 10450 WATTS MANUFACTURERS RECOMMENDATION 30 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. \EW PA \FL H Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 2.6 1 FMB -1 1000 10 3/20 X 1.00 1/0 20,030 TRANSFORMER 2 1.5 19,150 4 3 1000 X 3/125 4 4 17,165 6 SIGN 1.2 5 1000 120 X SUPPLEMENTAL HVAC 7 SPACE .125 — — X — -- -- SPACE 8 TOTALS: 4 9 SPACE — -- -- X — — — SPACE 10 11 SPACE — — — X — — -- SPACE 12 13 GENERAL LIGHTING 1800 12 1/20 X -- — -- SPACE 14 15 GENERAL LIGHTING 320 12 1/20 X -- — — SPACE 16 17 GENERAL LIGHTING 480 12 1/20 X — — -- SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 22830 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20470 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18645 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61945 WATTS MANUFACTURERS RECOMMENDATION 172 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. ` -4 VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. - L- CTRICAL LOAD S„ V V ARY • 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK OVERRIDE SWITCHES • • SIGN LIGHTS (B15) • 1 L_____..J GENERAL LIGHTS (B3) GENERAL LIGHTS (B15) GENERAL LIGHTS (017) PA EL RISER DIAGRAV 277/480V 3 PH, 4 WIRE ELECTRICAL SERVICE VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. NEW PANEL 'H' NEW PANEL .B. GRAvI GENERAL NOTES 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDU RISER DIAGRAM OTES BY SYvIBOL PROVIDE AND INSTALL ® GROUND TO BUILDING STEEL PER N.E.C. 250 -66 c 10 11 13 14 PRO !E PROVIDE ND INSTALL AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. PROVIDE A ► INSTALL LOCATION IN FIELD. PROVIDE AND INSTALL PROVIDE AND INSTALL PROVIDE AND 'INSTALL NOT USED PROVIDE AND INSTALL PROVIDE AND INSTALL NOT USED PROVIDE AND INSTALL PER NEC 250 -122 PROVIDE AND INSTALL PROVIDE AND INSTALL PROVIDE AND INSTALL REQUIRED ETER PER LOCAL TY AND LOCAL AUTHOR ' RECOMMENDATIONS. 200 AM 'IS NECT FUSED AT 125 AMPS FOR TENA SERVICE. VERIFY (4) #1/0 THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUI (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'H'. (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RT 1--1 ON ROOF. 30 AMP DISCONNECT FOR FMB -1 IN CEILING. VERIFY LOCATION IN FIELD. (1) #4 CU, GROUNDING ELECTRODE CONDUCTOR TO BLDG. STEEL (3) #1/0 THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER W /#6 CU GROUND A 75 KVA FLOOR MOUNTED TRANSFORMER. (4) #3/0 THWN CU, (1) #6 GROUND IN 2° CONDUIT FOR PANEL 'A'. 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS Fc)NGE c o - to' col 2887 Southcenter Mall Tukwila, WA 98188 smith ear. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 No. Date Issues By Check 1 03.31.08 PERMIT KLS 2 05.08.08 PERMIT CORRECTIONS KLS Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG CITY OF TUKWILA MAY 0 9-1008 Scale AS NOTED IM A Template 4.3 (120101) r ;rcivtl I LINTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -2 LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH LIGHTING 2.6 1.25 3.3 120 1 RECEPTACLES 7.2 1.00 7.2 120 1 WATER HEATER 1.5 1.00 1.5 208 1 MISCELLANEOUS N/A 1.00 N/A 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC .1 1.25 .125 120 1 HVAC 11.0 + .25 OF LARGEST LOAD 13.8 480 3 TOTALS: 23.6 27.4 KW — 32 9 AMPS © 120/208 SERVICE • 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK OVERRIDE SWITCHES • • SIGN LIGHTS (B15) • 1 L_____..J GENERAL LIGHTS (B3) GENERAL LIGHTS (B15) GENERAL LIGHTS (017) PA EL RISER DIAGRAV 277/480V 3 PH, 4 WIRE ELECTRICAL SERVICE VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. NEW PANEL 'H' NEW PANEL .B. GRAvI GENERAL NOTES 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDU RISER DIAGRAM OTES BY SYvIBOL PROVIDE AND INSTALL ® GROUND TO BUILDING STEEL PER N.E.C. 250 -66 c 10 11 13 14 PRO !E PROVIDE ND INSTALL AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR TENANT SERVICE. PROVIDE A ► INSTALL LOCATION IN FIELD. PROVIDE AND INSTALL PROVIDE AND INSTALL PROVIDE AND 'INSTALL NOT USED PROVIDE AND INSTALL PROVIDE AND INSTALL NOT USED PROVIDE AND INSTALL PER NEC 250 -122 PROVIDE AND INSTALL PROVIDE AND INSTALL PROVIDE AND INSTALL REQUIRED ETER PER LOCAL TY AND LOCAL AUTHOR ' RECOMMENDATIONS. 200 AM 'IS NECT FUSED AT 125 AMPS FOR TENA SERVICE. VERIFY (4) #1/0 THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2" CONDUI (4) #1/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'H'. (3) #10 THWN CU, (1) #8 GROUND IN 3/4" CONDUIT FOR RT 1--1 ON ROOF. 30 AMP DISCONNECT FOR FMB -1 IN CEILING. VERIFY LOCATION IN FIELD. (1) #4 CU, GROUNDING ELECTRODE CONDUCTOR TO BLDG. STEEL (3) #1/0 THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER W /#6 CU GROUND A 75 KVA FLOOR MOUNTED TRANSFORMER. (4) #3/0 THWN CU, (1) #6 GROUND IN 2° CONDUIT FOR PANEL 'A'. 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS Fc)NGE c o - to' col 2887 Southcenter Mall Tukwila, WA 98188 smith ear. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 No. Date Issues By Check 1 03.31.08 PERMIT KLS 2 05.08.08 PERMIT CORRECTIONS KLS Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG CITY OF TUKWILA MAY 0 9-1008 Scale AS NOTED IM A Template 4.3 (120101) r ;rcivtl I LINTER All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -2 PART 1 - GENERAL 1.01 SCOPE OF WORK: FURNISH AND INSTALL ALL EQUIPMENT AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENT AND SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND /OR SPECIFIED HEREIN. ALSO ARE INCLUDED ALL OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION INCLUDING ALL ACCESSORIES AND APPURTENANCE REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWING AND SPECIFICATIONS THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. 1.02 REGULATORY REQUIREMENTS CODE COMPLIANCE IS MANDATORY. NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMITS WORK AND NOT CONFORMING TO THESE CODES. WHERE WORK IS SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (05H). 2. NFPA #70; NATIONAL ELECTRIC CODE (NEC). 3. NFPA #101: LIFE SAFELY CODE. 4, STATE FIRE MARSHAL. 5. LOCAL UTILITIES COMPANIES. 6. ALL LANDLORD GENERAL REQUIREMENTS FOR MAW 1.03 LICENSE. FEES AND PERMITS: ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMITS AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. 1.04 SAFETY AND INDEMNITY: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. NO ACT, SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER, THE ENGINEERS OR THEIR CONSULTANTS, IS INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, OR NEAR THE CONSTRUCTION SITE. 1.05 DRAWINGS AND SPECIFICATIONS: ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF THIS DIVISION SHOW ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENTS SHALL BE GOVERNED BY CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS, WHETHER SPECIFICALLY MENTIONED OR NOT. 1.06 CONDITIONS AT SITE: THE ELECTRICAL CONTRACTOR SHALL HAVE EXAMINED THE SITE AND FAMILIARIZED THEMSELVES WITH ALL DISCERNIBLE EXISTING CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS SHALL BE INCLUDED IN THE BID. 1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF WORK. THE CONTRACTOR SHALL BE A LICENSED MASTERED ELECTRICIAN OF THE STATE IN WHICH THE JOB I5 LOCATED. 1.08 SHOP DRAWINGS AND MATERIALS LISTS: SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS LISTS, AS NOTED BELOW, FOR REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. SUBMITTALS REQUIRED AS FOLLOWS: 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. 2. ENCLOSURES FOR UTILITY COMPANY METERING. 3. MAIN FUSED DISCONNECT SWITCH. 4. PANELBOARDS 5. DISCONNECT SWITCHES 6. LIGHT FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. 1.09 SUBSTITUTIONS: ONE OF MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION I5 PERMITTED. NO WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE 15 RECEIVED FROM THE OWNER. THE OWNER 15 THE SOLE JUDGE OF ACCEPTABILITY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM 15 PERMITTED, AND ANY RE- DESIGN EFFORT 15 THEREBY NECESSITATED, THE REQUIRED RE- DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.10 COORDINATION: COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH -IN AND CONNECTION FDR EQUIPMENT FURNISHED UNDER OTHER TRADES THAT REQUIRED ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES THAT REQUIRE ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABILITY AND CODE COMPUANCE. VERIFY EQUIPMENT DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. 1.11 CUTTING AND PATCHING: ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION IS INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND OTHER TRADES IS IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER HOLES, SUPPORTS, ETC. 1.12 ACCEPTANCE DEMONSTRATION: UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR OWNER THE OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. PROPERTY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND /OR TEST TIME SWITCHES PROGRAMMING. 1.13 RECORD DRAWINGS, EQUIPMENT DATA: MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH AS -BUILT INFORMATION AS FEEDER AND SERVICE ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION. DELIVER COMPLETED DRAWINGS TO THE OWNER. DEUVER TO THE OWNER'S REPRESENTATIVE THREE COPIES OF DATA SHEETS OR OTHER CURRENT MANUFACTURERS PUBLICATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT INCLUDING AT LEAST THESE DATA: 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS LIST. 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. 3. USER'S MANUAL AND OPERATING INSTRUCTIONS. 4. MANUFACTURER'S WARRANTY. 1.14 CLEANUP RID THE PREMISES OF SCRAP MATERIALS, TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. 1.15 GUARANTEE: GUARANTEE THE INSTALLATION FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHANGE. 1.16 TEMPORARY SERVICES: PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE PREMISES FOR BENEFICIAL OCCUPANCY. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: 1. THREE 20 -AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE GFI TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA REQUIREMENTS. 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARALLEL TO THE DEMISING WALLS, WITH ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN ROWS TO SIXTEEN FEET OR LESS. 3. FLOOD LIGHTING AND TASK LIGHTING FOR PAINTING AND OTHER FINISH WORK. WHEN PERMANENT ELECTRICAL SERVICE 15 OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT USED FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR REMOVAL OF TEMPORARY SERVICE PROVISIONS. 1.17 OWNER- FURNISHED ITEMS: CONTRACTOR SHALL INSTALL, CONNECT AND COMPLETE THE FOLLOWING ITEMS FURNISHED BY THE OWNER AND SHALL PROVIDE WIRES, CABLES, CONNECTORS, PIGTAILS, CORDS AND CORD -CAPS, BOXES, CONDUIT, PLATES, SUPPORTS, AND. OPERATING TESTS TO MAKE COMPONENTS AND SYSTEMS OPERATE SATISFACTORILY. PROVIDE SYSTEMS DRAWING FROM THE MANUFACTURER THROUGH THE OWNER IN ORDER TO INSTALL COMPLETE OPERABLE SYSTEM. 1. MUSIC SOUND SYSTEM COMPONENTS. 2. ENTRY ALARM SYSTEM CONTROL PANEL AND CONTACTS /SECURITY SYSTEMS. PART 2 - PRODUCTS 2.01 MATERIAL APPROVAL ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITER'S LABORATORIES LABEL. MATERIALS THAT ARE NOT COVERED BY UL TESTING STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AhILR INSTALLATION. 2.02 CONDUITS AND OTHER RACEWAYS: A. RIGID STEEL: HOT- DIPPED GALVANIZED. B. INTERMEDIATE METAL CONDUIT (IMC): HOT- DIPPED GALVANIZED C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO- GALVANIZED. D. WIREWAY CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND OUTDOORS. 2.03 WIRES AND CABLES: A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: 1. CONDUCTOR: MINIMUM SIZE #12 A. #12 AND #10 AWG SOUD COPPER. B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. 2. INSULATION TYPE: A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THWN FOR DRY LOCATIONS. B. #10 THROUGH #4/0 AWG: XHHW (55 MILS). C. #250 MCM AND LARGER XHHW (65 MILS). D. GROUNDING WIRE: TIN. B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #16 AWG MINIMUM, WITH THWN INSULATION FOR UNDERGROUND OR WET LOCATIONS AND THHN INSULATION FOR DRY LOCATIONS. C. ACCEPTABLE PRODUCTS GENERAL ELECTRIC, ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING APPLICABLE IPCEA STANDARDS. 2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: A. OUTLET BOXES: 4" SQUARE X 1 - I/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO -TYPE WITH PLASTER RING AND COVER FOR GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). B. JUNCTION BOXES SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE- GAUGE STEEL IN LARGER SIZES WITH SURFACE OR FLUSH -TYPE SCREW - MOUNTED TRIM COVERS, BOTH BOXES AND COVERS INHIBITOR- PRIMED AND PAINTED INSIDE OUT. C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN 4- 11/16" SQUARE X 2 -1/8" DEEP WITH SINGLE -GANG RING AND SIERRA #S -754N SPUT PLATE BUSHING. E. ALL BOXES AND ASSOCIATED COMPONENTS SHALL BE STEEL CITY 683 SERIES, WITH P60 -3B COVERPLATE. 2.05 WIRING DEVICES AND PLATES: WIRING DEVICES AND PLATES SHALL BE HUBBELL ARROW HART, GE OR P &S WITH HUBBELL NUMBERS USED TO SPECIFY TYPE USED. STANDARD DESIGN: A. SWITCH AND RECEPTACLES DEVICES SHALL BE IVORY EXCEPT WHEN THE DEVICE 15 LOCATED ORE A PURPLE WALL, WHEN ON PURPLE WAIL DEVICE SHALL BE BLACK B. ISOLATED GROUND RECEPTACLES SHALL BE WHITE WITH ORANGE TRIANGLE AS REQUIRED PER NEC, MANUFACTURED BY LEVITON # 5362 --IGW OR APPROVED EQUAL. C. SWITCHES SHALL BE 20 AMP, 120/277 VOLT A.C. RATED SINGLE POLE SWITCHES SHALL BE #1221 AND 3 -WAY SWITCHES SHALL BE #1223. D. RECEPTACLES SHALL BE GROUNDING TYPE #5362. 2.06 CONDUIT HANGERS: FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR POWERSTRUT. FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM DEFLECTION NOT GREATER THAN 1/8" 2.07 WIRE CONNECTORS: FOR WIRE SIZES #8 AWG AND SMALLER INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C. 600V, FOR BUILDING WIRING AND 1000W IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL. FOR WIRE SIZE #6 AWG AND LARGER T & B OR EQUIVALENT COMPRESSION TYPE WITH 3M #33 OR PLYMOUTH "SLIPKNOT GRAY" TAPE INSULATION. 2.08 PANELBOARD: A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL BE OF COLD - ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20 ". FINISH EXPOSED PART WITH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GRAY ENAMEL SUITABLE FOR OVER PAINTING IN FIELD IT DESIRED. B. BUS BARS: PROVIDE GROUND BLOCK WITH FULL COMPLEMENT OF TERMINALS IN ADDITION TO INSULATED NEUTRAL BUS. FUTURE BREAKER SPACES SHALL HAVE COMPLETE PROVISION INCLUDING BUSSES AIR CONNECTING HARDWARE. C. MANUFACTURER PANELBOARD SHALL IN GENERAL ELECTRIC TYPE AQ OR TYPE AE OR EQUIVALENT PRODUCTS OF CUTTER- HAMMER, SQUARE D, OR SIEMENS -ITE. D. CIRCUIT BREAKERS SHALL BE BOLT -ON, THERMAL - MAGNETIC, MOLDED CASE TYPE: U.L. LISTED FOR SWITCHING DUTY. BREAKERS SHALL HAVE ON OVER- CENTER TRIP FREE, TOGGLE TYPE HANDLE WITH QUICK -MAKE, QUICK -BREAK ACTION. 1. 120/208 VOLT PANELS: SHALL BE GENERAL ELECTRIC TYPE "Q" UNE, BOLT -ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING CAPACITY AS SHOWN. NO SERIES RATING ALLOWED. 2. PROVIDE MULTI -POLE UNITS WITH COMMON TRIP ELEMENT. 3. CIRCUIT BREAKERS USED ON "ON -OFF" CONTROL OF FLUORESCENT LIGHTING (PANELBOARD SWITCHING) SHALL BE UNDERWRITERS- LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABIUTY. E. IDENTIFICATION: PROVIDE SCREWED -ON (NO ADHESIVES) BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION AN OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE, AND PHASE IN MINIMUM 1/4" HIGH LETTERS. EACH PANEL SHALL CONTAIN A METAL - FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. F. COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. 2.09 DRY TYPE TRANSFORMER: A. GENERAL: EQUIPMENT SHALL CONFORM TO OR EXCEED REQUIREMENTS OF NEMA, ANSI STANDARD C89.2 FOR DRY TYPE TRANSFORMERS FOR GENERAL APPLICATIONS. ACCEPTABLE PRODUCTS ARE THOSE OF GENERAL ELECTRIC COMPANYS "QHT" UNE OR EQUIVALENT SQUARE D, SIEMENS -ITE, OR CUTTLER- HAMMER. ELECTRICAL RATINGS: 1. PRIMARY WINDINGS VOLTAGE 480 VOLTS, 3- PHASE, DELTA. SECONDARY WINDING VOLTAGES 208Y/120 VOLTS, 3 -PHASE GROUNDED. FREQUENCY: 60 HZ. KVA RATING: AS SHOWN ON DRAWINGS. TOPS: SIX (6) 2.5% FULL CAPACITY TAPS, 2 ABOVE AND 4 BELOW, RATED VOLTAGE. IMPEDANCE: FOR TRANSFORMERS LARGER THAN 75 KVA, 4.5% MINIMUM, 5.75 MAXIMUM 2. WINDING TEMPERATURE RISE SHALL BE 150 DEGREES CENTIGRADE IN ACCORDANCE WITH UL SPECIFICATION ARTICLE 506. 3. TRANSFORMER SHALL BE CAPABLE OF OPERATING AT 100% OF NAMEPLATE RATING CONTINUOUSLY WHILE IN AN AMBIENT TEMPERATURE NOT EXCEEDING 40 DEGREES CENTIGRADE. 4. TRANSFORMER SHALL MEET THE DAILY OVERLOAD REQUIREMENTS OF ANSI STANDARD C57.96. C. VIBRATION ISOLATION, FACTORY - INSTALLED: PROVIDE NEOPRENE RUBBER PADS TO ISOLATE CORE AND COIL ASSEMBLY FROM TRANSFORMER ENCLOSURE. D. INSTALLATION: 1. ANCHOR TRANSFORMER SECURITY WIN MINIMUM 1/2" DIAMETER BOLTS. STRENGTH OF BOLTS USED TO SECURE THE TRANSFORMER SHALL BE SUFFICIENT TO RESIST SHEAR AND UPLIFT PRODUCED BY FORCE EQUAL TO 1/2 OF THE EQUIPMENT MASS APPLIED HORIZONTALLY AT ENTER OF GRAVITY. 2. PROVIDE 1 THICK HIGH RESILIENCY PADS TO ISOLATE TRANSFORMER FROM FLOOR OR PLATFORM. KORFUND "ELASTO RIB" OR EQUIVALENT. 3. USE FLEXIBLE CONDUITS AT LEAST 24" LONG FOR ELECTRICAL CONNECTIONS. 4. PROVIDE GROUNDING OF EACH TRANSFORMER SECONDARY INCLUDING ALL CONDUITS. WIRES, AND CONNECTORS IN ACCORDANCE WITH NEC 250 -26 AND ANY LOCAL ADDITIONAL REGULATIONS. 2.10 INDIVIDUALLY MOUNTED MOTOR CONTROLLER: A. FOR POLYPHASE MOTORS: COMBINATION MOTOR CIRCUIT PROTECTOR AND MAGNETIC STARTER, WITH 3 -LEG OVERLOAD PROTECTION. PROVIDE TWO INTERLOCK CONTACTS OF THE INTERCHANGEABLE OPEN -CLOSE TYPE. PROVIDE HAND -OFF AUTOMATIC SELECTOR SWITCH, MOTOR RUNNING PILOT LIGHT AND RESET BUTTON IN COVER. CIRCUITS 300V AND OVER SHALL BE PROVIDED WITH INDIVIDUAL 120V CONTROL TRANSFORMERS. B. STARTERS FOR FRACTIONAL HORSEPOWER 120V MOTORS SHALL BE MANUAL TYPE UNLESS SHOWN OTHERWISE, EQUIPPED WITH BUILT -IN OVERLOAD PROTECTION. C. ACCEPTABLE MANUFACTURERS GENERAL ELECTRIC SIEMENS, SQUARE 0, CUTTER- HAMMER, AND ALLEN BRADLEY. 2.11 LIGHTING A. LIGHTING TO BE PROVIDED BY OWNER. SUBCONTRACTORS TO INSTALL ALL FIXTURES COMPLETE, INCLUDING LAMPS AND BALLASTS, READY FOR SERVICE. B. SUPPORTS: PROPER SUPPORTS AND MOUNTING ACCESSORIES, SUCH AS HANGERS, STEMS, YOKES, PLASTER FRAMES, ETC SHALL BE PROVIDED AS REQUIRED BY THE TYPE OF CEILING INSTALLED. WHERE AUG PLUMP SWIVEL CANOPIES OR BALL NERS ARE SPECIFIED THEY SHALL CAUSE FIXTURE TO HANG PLUM REGARDLESS OF CEILING SLOPE. C. FIXTURE DESIGNATION: FIXTURE TYPES ARE DESIGNATED ON DRAWINGS, WHERE ONLY ONE FIXTURE DESIGNATION 15 SHOWN, IT APPLIES TO ALL FIXTURES IN THAT ROOM OR AREA. FOR EXACT FIXTURE COUNT AND LOCATION REFER TO REFLECTED CEILING PLAN. D. WIRE 1 -LAMP AND 3 -LAMP FLUORESCENT FIXTURES IN TANDEM WHERE REQUIRED BY CODE. E. BALLASTS: ADVANCE, GE, OR APPROVED HIGH FREQUENCY ELECTRONIC, FULL LIGHT OUTPUT, ENERGY SAVING, CLASS "P ", HIGH POWER FACTOR. ETL CERTIFIED, SOUND RATING "A" OR AS INDICATED ON DRAWINGS. 2.12 MISCELLANEOUS MATERIALS: A: SAFETY SWITCHES: HEAVY DUTY TYPE, 600V, HORSEPOWER RATED FOR MOTORS, FUSED OR NON -FUSED AS REQUIRED. MOUNT IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR CUTLER - HAMMER. PART 3 - EXECUTION 3.01 GENERAL A. ELECTRIC SYSTEM LAYOUTS INDICATED ON THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. GOVERN EXACT ROUTING OF CABLE AND WIRING AND THE LOCATIONS OF OUTLETS BY THE STRUCTURE AND EQUIPMENT SERVED. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS. B. CONSULT ALL OTHER DRAWINGS, VERIFY SCALES AND REPORT ANY DIMENSIONS, DISCREPANCIES OR OTHER CONFLICTS WITH OWNER BEFORE SUBMITTING BID. C. ALL HOME RUNS TO PANELBOARDS ARE INDICATED AS STARTING FROM THE OUTLET NEAREST THE PANEL AND CONTINUING IN THE GENERAL DIRECTION OF THAT PANEL CONTINUE SUCH CIRCUITS TO THE PANEL AS THOUGH THE ROUTES WERE COMPLETELY INDICATED. TERMINATE HOMERUNS OF SIGNAL, ALARM, AND COMMUNICATION SYSTEMS IN A SIMILAR MANNER. D. AVOID CUTTING AND BORING HOLES THROUGH STRUCTURE OR STRUCTURAL MEMBERS WHEREVER POSSIBLE. OBTAIN PRIOR APPROVAL OF OWNER AND CONFORM TO ALL STRUCTURAL REQUIREMENTS WHEN CUTTING OR BORING THE STRUCTURE IS NECESSARY AND PERMITTED. E. FURNISH AND INSTALL ALL NECESSARY HARDWARE, HANGERS, BLOCKING, BRACKETS, BRACING, RUNNERS, ETC. REQUIRED FOR EQUIPMENT SPECIFIED UNDER THIS SECTION. F. PROVIDE NECESSARY BACKING REQUIRED TO INSURE RIGID MOUNTING OF OUTLET BOXES. 3.02 WIRING METHODS: A. NO 'ROMEX' OR 'BX' WIRING IS PERMITTED - ALL ELECTRICAL WIRING MUST BE IN CONDUIT. B. CONDUIT SHALL BE RIGID STEEL, IMC OR EMT AS FOLLOWS: 1. ABOVE GROUND: USE RIGID STEEL IMC OR EMT. A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. B. LOCATIONS SUBJECT TO MECHANICAL INJURY: RIGID STEEL OR' IMC ONLY. C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMC OR RIGID STEEL CONDUIT 2. UNDERGROUND: USE RIGID STEEL. C. USE FLEXIBLE CONDUITS IN THE FOLLOWING APPLICATIONS. 1. RECESSED LIGHTING FIXTURES. 2. MOTOR CONNECTIONS. 3. AT BUILDING JOINTS AND WET LOCATIONS, FLEXIBLE CONDUIT SHALL BE UQUID TIGHT TYPE. D. LIGHT FIXTURES INSTALLED IN SHEETROCK CEILINGS MAY BE WIRED FROM FIXTURE TO FUTURE USING METAL CLAD (MC) CABLE. VERIFY THAT LIGHT FIXTURES ARE PROVIDED WITH JUNCTION BOXES APPROVED FOR THIS PURPOSE. MC TYPE CABLE TO MEET ANSI /NFPA 70 REQUIREMENTS. CABLE ARMOR TO BE INTERLOCKED STEEL METAL TAPE. MC TYPE CABLE MANUFACTURED BY AFC CABLE SYSTEMS, PIRELLI CABLE CORPORATION AND SOUTHWIRE COMPANY ARE APPROVED. MC CABLE SHALL NOT BE USED TO WIRE LIGHT FIXTURES INSTALLED IN LAY -IN OR EXPOSED CEILINGS, OR TO WIRE RECEPTACLES. 3.03 INSTALLATION OF CONDUITS: GENERAL 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENILR LINES OF COLUMNS END BEAMS. 3. CONDUITS ABOVE CEILINGS SHOULD NOT OBSTRUCT REMOVAL OF CEILING TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED WITH MECHANICAL WORK TO AVOID ANY CONFLICT. B. CONDUIT SUPPORTS: 1. SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURE AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY CONDUIT TO MECHANICAL DUCTS OR PIPES. 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING SUPPORT WIRES WITH CADDY CLIPS ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT 15 PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG SUCH CONDUIT 50 AS NOT TO AFFECT LEVEL OF CEILING. - 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT I5 NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURE. C, CONDUIT PENETRATION: 1. PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING. SEAL PENETRATION WITH FIRE RETARDANT SEALANT SPECIFIED HEREIN. 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF OR EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL: INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS DETAILED ON THE DRAWINGS. 4. PENETRATING NON -FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED. PENETRATIONS MUST BE SEALED WITH PLASTER PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH 15 APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH ESCUTCHEONS, ONE ON EACH SIDE OF WALL. 5. PENETRATING SUSPENDED CEILING: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION. PROVIDE ESCUTCHEON FOR EACH CONDUIT BELOW CEILING. 3.04 CONNECTIONS TO EQUIPMENT: A. GENERAL 1. FURNISH AND INSTALL REQUIRED POWER SUPPLY CONDUIT AND WIRING TO ALL EQUIPMENT. SEE BELOW FOR OTHER WIRING REQUIRED. 2. FURNISH AND INSTALL A DISCONNECT SWITCH IMMEDIATELY AHEAD OF AND ADJACENT TO EACH MAGNETIC MOTOR STARTER OR APPLIANCE UNLESS THE MOTOR APPLIANCE IS LOCATED ADJACENT AND WITHIN SIGHT OF THE SERVING PANELBOARD, CIRCUIT BREAKER OR SWITCH. VERIFY ALL EQUIPMENT NAMEPLATE CURRENT RATINGS PRIOR TO INSTALLATION. 3. INSTALL ALL ROUGH -N WORK FOR EQUIPMENT FROM APPROVED SHOP DRAWINGS TO SUIT THE SPECIFIC REQUIREMENTS OF THE EQUIPMENT. - 4. FURNISH AND INSTALL MANUAL THERMAL PROTECTION FOR ALL MOTORS NOT INTEGRALLY EQUIPPED WITH THERMAL PROTECTION. 5. FURNISH 120 VOLT POWER TO EACH CONTROL PANEL AND TIME SWITCH REQUIRING A SOURCE OF POWER TO OPERATE. 3.05 INSULATION OF WIRES: A. PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS BEEN COMPLETED. B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL. SPLICES IN CABLES WHERE REQUIRED SHALL BE MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES. MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8" OF CORRECTLY COLOR -CODED TAILS LEFT IN THE BOX. C. SPUCES IN WIRES AND CABLES SHALL BE MADE URUZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. D. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS TO RECEPTACLE AND WIRING DEVICE TERMINALS AS RECOMMENDED BY MANUFACTURER. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE IS NOT APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. E. PROVIDE BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD. 3.06 WIRE COLOR CODE: COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12 THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF ANY SIZE IN CABLE ASSEMBUES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND 120/208V BLACKRED BLUE WHITE GREEN 277/480V BROWN ORANGE YELLOW GRAY GREEN 3.07 IDENTIFICATION A. PROVIDE NAMEPLATES FAR SWITCHGEARS, PANELBOARD, AND ALL SIMILAR DEVICES. NAMEPLATES SHALL BE SCREWED (NO ADHESIVES) ENGRAVED BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION SHOWING PANEL DESIGNATORS, VOLTAGE AND PHASE IN MINIMUM 1/4" HIGH LETTERS. B. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND CIRCUIT NUMBER TO WHICH THE DEVICE IS CONNECTED. C. EACH BOARD SHALL CONTAIN A METAL - FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. D. PANELBOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANELBOARD SCHEDULES FOR AL PANELBOARD. 3.08 GROUNDING A. ELECTRICAL SERVICE AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEMS SHALL BE GROUNDED IS ACCORDANCE WITH NEC ARTICLE 250 -3 TO 250 -26, INCLUSIVE. B. GROUND NON- CURRENT CARRYING METAL PORTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR CABLE TRAYS TO PROVIDE A LOW IMPEDANCE PATH FOR UNE -TO- GROUND FAULT CURRENT AND TO BOND ALL NON - CURRENT CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250- -95 UNLESS LARGER CONDUCTORS ARE SHOWN ON DRAWINGS. C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION. WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER SIZES, BLOCK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVICE ENCLOSURE. END OF SECTION .per'"` CODS COVOINIO 2887 Southcenter Mall Tukwila, WA 98188 smith cc 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Architect Registration 6294 REGISTERED ARCWITECT KEI STATE OF WASHINGTON Issues and Revisions No. Date Issues By Check 1 03.31.08 PERMIT K LS Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description ELECTRICAL SPECIFICATI ❑NS Computer File CW05- 2008- E3,DWa,,,,aor W AFi 2 4 2uOi Scale AS NOTED PERMIT CENTEF, Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. E -3