Loading...
HomeMy WebLinkAboutPermit EL08-0463 - WESTFIELD SOUTHCENTER MALL - SEATTLE TEAM SPORTS KIDSSEATTLE TEAM SHOP KIDS 1067 SC MALL 07-23-08 ELO8-463 Parcel No.: Address: Suite No: Cityif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 6364200010 1067 SOUTHCENTER MALL TUKW Permit Number: EL08 -463 Issue Date: 05/19/2008 Permit Expires On: 01/12/2009 Tenant: Name: Address: Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: SEATTLE TEAM SPORTS KIDS 1067 SOUTHCENTER MALL , TUKWILA WA WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD CA KEITH SMITH 1725 WESTLAKE AVE N STE 210 , TUKWILA WA S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: Phone: 206 - 713 -4076 Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: NEW SERVICE, PANELS AND CIRCUITS Value of Electrical: Type of Fire Protection: $25,500.00 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Fees Collected: National Electrical Code Edition: $751.50 2005 Date: g I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction e performance of work. I am authorized to sign and obtain this electrical permit. Signature: Print Name: Date: 11231g This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -463 Printed: 07 -23 -2008 Cityilf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1067 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -463 Issue Date: 05/19/2008 Permit Expires On: 01/12/2009 Tenant: Name: SEATTLE TEAM SPORTS KIDS Address: 1067 SOUTHCENTER MALL , TUICWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 - 713 -4076 Address: 1725 WESTLAKE AVE N STE 210 , TUKWILA WA Contractor: Name: S M E INC OF SEATTLE Phone: 206 329 -2040 Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Expiration Date: 03/02/2010 DESCRIPTION OF WORK: NEW SERVICE, PANELS AND CIRCUITS Value of Electrical: $25,500.00 Fees Collected: $751.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of thi permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or th erformance of wo . I am authorized to sign and obtain this electrical permit. Signature: '- Date: Print Name: L.UY r/'' " V v 1 r L This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -463 Printed: 07 -23 -2008 Citylif Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http.• / /www.ci.tukwila.wa.us ELECTRICAL PERMIT Parcel No.: 6364200010 Address: 1067 SOUTHCENTER MALL TUKW Suite No: Permit Number: EL08 -463 Issue Date: 05/19/2008 Permit Expires On: 11/15/2008 Tenant: Name: WESTFIELD VANILLA BOX Address: 1067 SOUTHCENTER MALL , TUKVVILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: KEITH SMITH Phone: 206 - 713 -4076 Address: 1725 WESTLAKE AVE N STE 210 , TUKWILA WA Contractor: Name: S M E INC OF SEATTLE Address: 828 POPLAR PL S , SEATTLE WA Contractor License No: SMEINS *066DB Phone: 206 329 -2040 Expiration Date: 03/02/2010 DESCRIPTION OF WORK: NEW SERVICE, PANELS AND CIRCUITS Value of Electrical: $25,000.00 Fees Collected: $615.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: X-1 � Y‘11) I hereby certify that I have read and ex : ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied ' hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction orate performance of work. I am authorized to sign and obtain this electrical permit. (mot) GL,_ Signature: Print Name: Y Vl L Da.,r e. Date: 5 / ( -9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -463 Printed: 05-19 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 1067 SOUTHCENTER MALL TUKW Suite No: Tenant: WESTFIELD VANILLA BOX Permit Number: EL08 -463 Status: APPROVED Applied Date: 04/24/2008 Issue Date: 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature:`-' Date: - I .010e Print Name: wY�` via 1^e_, doc: Cond -Elec EL08 -463 Printed: 05-19 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCH' King Co Assessor's Tax No.: (o ff'i 2-) — Site Address: /0 67 se C Pte., Y /44 l % J / i k, / / (Suite Number Floor: / 6 Tenant Name:! & 4 e /j . , i / 8 Property Owners Name: I i ` ! i %f Mailing Address: _ / 7 /L //� Mt W�v���' UMW New enant: Yes ❑..No City tate Zip ONTACT PERS( Name: Mailing Address: E -Mail Address: Who do iI '"1 M4 e contact w en yogr permit ts ready'to be issued '414 t 4 - 5 9 e t t z 1 a cnit41 e a pv Day elephone: City Fax Number: 9 -e Zip (,,',ELECTRICAIi CONTRACTORINFORMATIC Company Name: -7717 Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip Valuation of Project (contractor's bid price): $ i56 6 Scope of Work (please provide det led information): 0(61/1 5 5a/V1 4(1 /4H/4 in 1 Will service be altered ?r Yes, Type of Use: Type of work: New ❑ Low Voltage Pro a Served b : Puget Sound Energy ❑ Seattle City Light ❑ No Adding more than 50 amps? Yes ❑ No ❑ Addition ❑ Service Change ❑ Generator ❑ Fire Alarm IMApplications\Forms- Applications On Line \4 -2007 - Electrical Permit Application.doc bh ❑ Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT, APPLICATION NOTE Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: W Print Name: Mailing Address: I.175.wo -to nee J, Day Telephone: City Date: 442 to IDate Application Accepted: Date Application Expires: [ 0-0)-11 -0 Staff Initials: H: Applications\Forms- Applications On line \4 -2007 - Electrical Permit Application.doc bh Page 2 of 2 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us 6364200010 1067 SOUTHCENTER MALL TUKW SEATTLE TEAM SPORTS KIDS RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -463 ISSUED 04/24/2008 05/19/2008 Receipt No.: R08 -02709 Initials: WER User ID: 1655 Payee: Payment Amount: $78.50 Payment Date: 07/23/2008 09:22 AM Balance: $0.00 SME OF SEATTLE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21199 78.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 ELECTRICAL PLAN - NONRES 000.345.832.00.0 74.40 4.10 Total: $78.50 doc: Receipt -06 Printed: 07 -23 -2008 Parcel No.: Address: Suite No: Applicant: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www. ci. tukwila. wa. us 6364200010 1067 SOUTHCENTER MALL TUKW WESTFIELD VANILLA BOX RECEIPT Permit Number: Status: Applied Date: Issue Date: EL08 -463 ISSUED 04/24/2008 05/19/2008 Receipt No.: R08 -02278 Initials: User ID: Payee: WER 1655 Payment Amount: $58.00 Payment Date: 06/24/2008 03:07 PM Balance: $0.00 SME INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 21154 58.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 58.00 Total: $58.00 4049 06/24 9711 TOTAL 406.00 doc: Receiot -06 Printed: 06-24 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http:/1www.citukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01707 Initials: JEM Payment Date: 05/19/2008 User ID: 1165 Total Payment: 4,752.00 Payee: SME, INC. OF SEATTLE SET ID: 0519 SET TRANSACTIONS: Set Member Amount EL08 -353 492.00 EL08 -460 852.00 EL08 -461 852.00 EL0,8 -462 852.00 852.00 EL O 852.00 TOTAL: 4,752.00 SET NAME: WESTFIELD VANILLA BOXES TRANSACTION LIST: Type Method Description Amount Payment Check 21106 ACCOUNT ITEM LIST: Description TOTAL: 4,752.00 4,752.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 2,952.00 000.345.832.00.0 1,800.00 TOTAL: 4,752.00 2593 05/19 9711 TOTAL 4752.00 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -463 Address: 1067 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 04/24/2008 Applicant: WESTFIELD VANILLA BOX Issue Date: Receipt No.: R08 -01316 Payment Amount: $123.00 Initials: WER Payment Date: 04/24/2008 11:20 AM User ID: 1655 Balance: $492.00 Payee: WESTFIELD TRANSACTION LIST: Type Method Descriptio Amount Payment Check 06012501 123.00 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.0 123.00 Total: $123.00 1611 04/24 9711 TOTAL 1094.80 <4\ doc: Receiot -06 Printed: 04 -24 -2008 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT O. CITY OF TUKWILA BUILDING DIVISION f- 6300 Southc te #100, Tukwila, WA 98188 (206)431 -360 Pr•'- ' Type of Inspection: Date Called: Special Instructio s: Date Wanted: 2 a.m. Requester: Phone No: 140-e_d Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: OK. nspector: lat du\'Date: c ( 2,? ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERM CITY OF TUKWILA BUILDING DIVISION vQ 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 Project: Type of Inspection: a) act)riiC y y0L"'1GL f7'l ( ///sF Ad s; 007 SC- fl/91L Date Called Special Instructions: Date Wanted: a.m. p.m. Requester: cl lfl PLr-4 11) L cec. /1/4.'6e/11 Phone No: s)�cifii iJL 1 M/ alexx c..�� 4. roved per applicable codes. Corrections required prior to approval. COMMENTS: pig, a) act)riiC y y0L"'1GL f7'l ( ///sF l...oL.c S F2, 11/1/1 4S e. '' CAM / /.,E 7 Mat_ Sc,f /L U'L .S L)fl!,1LI/'ti, 1'411 <- /A) i (I i/9,EL- cl lfl PLr-4 11) L cec. /1/4.'6e/11 s)�cifii iJL 1 M/ alexx c..�� Z C.z./i7i 77 GL /i' / G UA)M/ ci9 ./ _ f he14a14 coat/. fI S /= =. '-/-11R 5 a< 7) z 7 Q ( Inriz, ...� Ka16/- Date io kI� $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit eta -L{b3 PERMIT NO. (206)431 -3670 Project: a ( _�� 41 Type of Inspection: 3 DO Address: ® Date Called: Special Instructions: Date Wanted: 1 1� all%: Requester: Phone No: NApproved per applicable codes. Corrections required prior to approval. COMMENTS: - CE ILA IN) C4(4%. irj Inspector: 6(-4Akt. Date:t tt El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ..w:a..,14a.. _.��.�:��•1'w4.7.t�.'', INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit tv$-`1,3 PERMR NO. (206)431 -3670 'Project: , �� 60/ Type of Inspection: 7003 Address: too ' 144, Date Called: Special Instructions: Date Wanted: 6/TO m. p. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: O.K. - 5-r oen-rt f-r-- (Inspector: `.! &NILS( Ite 04/3°174 El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: INSPECTION NO. INSPECTION RECORDS F— �� Retain a copy with permit (®� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: (3o7< Type of Inspg tio�: _ y l�� Aee : Date Called: special Instructions: Date Wanted: a.m. p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. C MMENTS: f/4 (9/4 -- /e)T.4gi IA/1j it., InspectorAu f)'A &' /Ql Date6 /2-/ok 0 $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 4-0C(9413 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prp/4.14 eciX Type of Inspection: 700 _� Ad is ss _. 45 Date Called: Special Instructions: Date Wanted: J 'i .m. Requester: Phone No: proved per applicable codes. El Corrections required prior to approval. JDate: OMMENTS: /kte K*r 41/0 /6,0e 1-1 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit Ca'V-Y63 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 12-- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project:I�� Type of Inspection: ��� Address: �p� � 11 Date Called: 7., Special Instructions: Date Wanted: A a.m. p.m Requester: Phone No: 0 Approved per applicable codes. Corrections required prior to approval. COMMENTS: F4 Inspector: Date: 0 `/ liv•szj El $58.00 REINSPECTION FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call the schedule reinspection. Receipt No.: Date: 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Farms Revised July 2007 Project Info Project Address 1067 Southcanter Mall Date 6/11/2008 Tukwila, WA 98188 For Building Department Use Applicant Name: Keith kith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, WA 98109 FTC r' J L ,a .an Permit No. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUN 20 2008 � E V »VI ity Of Tukwila B ILDING DIVI ION REVISION' dal ELO9 y b 3 R C1NEF JUN 1 3 2008 PIT CENTEI 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting 1Summary LTG -INT 2006 Washington Stale Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 1067 8outhcenter Mail Date 6/11/2008 Tukwila, WA 98188 For Building Department Use 101 Applicant Name: Keith smith Applicant Address: 1735 Westlake Ave. N, Suite 210 Applicant Phone: ssettle, WA 98109 Project Description 103 ❑ New Building ❑ Addition El Alteration - Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive 0 Lighting Power Allowance (See Qualification Checklist (over). Indicate Prescriptive & LPA 0 Systems Analysis spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) 48.0 IN No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft 2** Area in ft2 Allowed x Area 101 retail 1.50 795.0 1192.5 103 stock room 0.50 80.0 40.0 103 Ll - CANOPY MTD. LINEAR FLUORESCENT 1 48.0 48.0 From Table 15 -1 (over) - document all exceptions on form LTG -LPA Proposed Lighting Wattage Total Allowed Watts 1232.5 Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 Li - CANOPY MTD. LINEAR FLUORESCENT 8 48.0 384.0 101 12 - RECESSED FLUORESCENT 8 26.0 208.0 103 Ll - CANOPY MTD. LINEAR FLUORESCENT 1 48.0 48.0 101 L3 - PENDANT 2 50.0 10 0. 0 101 L3 - LOW VOLTAGE TRACE 9 50.0 450.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1190.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting,'Motor, 2006 Washington Stale and Transformer Permit Plans Checklist i LTG;CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 1067 souchcencer nail 'Date 6/11/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) I Code Section Component Information Required l Location l on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controlaccess Schedule with type, indicate locations E-1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations a.a. vertical glazing Indicate vertical glazing on plans a.a. overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location Yea (a) timer w/backup Indicate location E-1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yea 1513.6.1 (a) occup. sensors Schedule with type and locations E_1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability): Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yea 1514 Max, watts Indicate watts for each exit sign 13 LIGHTING POWER ALLOWANCE (Section 1530 -1532) yea 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture no 1532 Exterior Lighting Summary Forrn Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yea I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency IM_2 TRANSFORMERS (Section 1540) yea I 1540 'Transformers 'Indicate size and efficiency 1E_2 I If "no" is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary; PRJ -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 1067 Southcenter Nall Date 4/7/2008 Tukwila, WA 98188 For Building Department Use Applicant Name: Keith Smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: seattla, WA 98109 FILE COpy Permit Flo. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAY 1 5 2008 ELO9M3 RECE9lEr• APR 2 42008 PERMIT CEN1 L 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Fans Revised July 2007 Project Info Project Address 1067 Southcenter Mall Date 4/7/2008 Tukwila, WA 98188 For Building Department Use 101 Applicant Name: Keith Smith Applicant Address: 1725 Westlake Ave. N, Suite 210 Applicant Phone: Seattle, vui. 98109 Project Description 103 ❑ New Building ❑ Addition J Alteration J Plans Included Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive ® Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2 " Area in ft2 Allowed x Area 101 retail 1.50 671.0 1006.5 103 stock room 0.50 144.0 72.0 104 toilet 0.80 60.0 48.0 •* From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 1126.5 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed 101 Ll - CANOPY MTD. LINEAR FLUORESCENT 6 96.0 576.0 101 12 - RECESSED FLUORESCENT 8 26.0 208.0 103 Ll - CANOPY MTD. LINEAR FLUORESCENT 2 96.0 192.0 104 Ll - CANOPY MTD. LINEAR FLUORESCENT 1 96.0 96.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 1072.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting. note section and exception number, and leave Watts/Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG;INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 0 Warehouses, storage areas or aircraft storage hangers 0 Other Q ualification Checklist Note: If occupancy type is "other and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Li htin Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools. hospitals, institutions, museums, banks, churches) Penitentiary and other Group 1 -3 Occupancies 1.0 1.0 _ Convention center 1.2 Courthouse 1.2 1.3 Police and fire stationsg Post office 1.0 1.1 Cafeterias, fast food establishmentss, restaurants /bars' Dormitory 1.0 Retail70, retail banking. mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasiag, assembly spaces u 1.0 Theater, motion picture Theater, performing arts 1.2 1.6 Health care clinic 1.0 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall" 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory° shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies' (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically. the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Lighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist; LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 1067 southcenter Mall 'Date 4/7/2008 is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements State Nonresidential Energy Code. The following information in the 2006 Washington Applicability) I es, no, n.a.) Code Section ( p Component Information Re wired Required I Location I on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controVaccess Schedule with type, indicate locations E-1 no 1513.2 Area controls Maximum limit per switch no 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans no 1513.4 Display /exhib /special Indicate separate controls 1513.5 Exterior shut -off Schedule with type and features, indicate location Yee (a) timer w/backup Indicate location E_1 no (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location yes 1513.6.1 (a) occup. sensors Schedule with type and locations E_1 no 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans no 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes I 1514 'Max, watts 'Indicate watts for each exit sign 1 13' I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yea 1531 Interior Lighting Summary Fomi Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture no 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes 1511 'Elec motor efficiency'MECH -MOT or Equipment Schedule with hp, rpm, efficiency 'M_2 TRANSFORMERS (Section 1540) yes I 1540 'Transformers 'Indicate size and efficiency 1E_2 ' If "no" is circled for any question, provide explanation: •P • • a2ith co Q May 9, 2008 Jim Benner City of Tukwila Building Department Tukwila, WA Architecture 1 Design 1 Planning 1 Retail RE: CORRECTION LETTER #I Development Application Number EL08 -463 Westfield Vanilla Space — 1067 Southcenter Mall Dear Jim, Below is the responses to your correction letter dated April 29, 2008. 1. Emergency lighting to be on area lighting circuit per N.E.C. 700.12(F). a. Added to area circuit lighting, see Sheet E -1 2. Ensure 1 foot/candle of emergency lighting along entire path of egress measured at the floor. a. Added note and additional emergency lighting along path of egress, see sheet E -1 3. Note 11 on riser diagram should include #6 cu. ground per N.E.C. 250.122 a. Added note, see sheet E -2 4. Note 12 should include #4 cu. grounding electrode conductor to building steel per N.E.C. 250.66 a. Added note, see sheet E -2 5. Note 13 should read "(4) #310 cu." a. Added note, see sheet E -2 6. Loads on transformer, Panel B, branch circuits, and load summary are inconsistent. a. Revised load summary 17 25 w e s t l a k e avenue north suite 21 0 seattle. Washington 98109 206.838.5485 p 206.464.0700 f .1 • • Page 2 May 9, 2008 7. RTU -1 is 208 volt or 480 volt? a. Panel B denotes 3 pole 50 amp breaker (208 volt) i. Panel revised no rtu, FMP -1 is 480v, see sheet E -2 b. Riser diagram (note 8) indicates 30 amp at 480 volt i. Corrected riser diagram note see sheet E -2 c. Power plan (note 4) indicates Panel H 1,3,5 VAV 3 pole 20 amp (480 volt) i. Revised note, see sheet e-I If you require any further information, please don't hesitate to phone me at (206) - 713 -4076. Regards, Keith L. Smith, AIA principal 1725 westlake avenue north suite 210 Seattle, Washington 98109 206.838.5485 p 206.464.0700 f April 30, 2008 • Cizy of Tukwila • Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Keith Smith 1725 Westlake Avenue N, Suite 210 Seattle, WA 98109 RE: CORRECTION LETTER #1 Electrical Permit Application Number EL08 -463 Westfield — Vanilla Box —1067 Southcenter Mall Dear Mr. Smith, This letter is to inform you of corrections that must be addressed before your electrical permit can be approved. All correction requests from the Building Department must be addressed and reflected on your drawings. Building Department: Jim Benner, at 206 431 -3679, if you have questions regarding the attached memo. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block.. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 433 -7165. Brenda Holt Permit Coordinator encl xc: File No. EL08 -463 P:\Permit Center \Correction Letters\2008\EL08 -463 Correction Ltr 41.DOC jem 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 • • Tukwila Building Division Jim Benner, Electrical ;Inspector Building Division Review Memo Date: April 29, 2008 Project Name: Westfield Vanilla Box Permit #: EL08- 463 Plan Review: Jim Benner, Electrical Inspector The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and /or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). Please include One Line Diagram, Load Summary, and Panel Directories (where applicable) 1. Emergency lighting to be on area lighting circuit per N.E.C. 700.12(F). 2. Ensure 1 foot/candle of emergency lighting along entire path of egress measured at the floor. 3. Note 11 on riser diagram should include #6 cu. ground per N.E.C. 250.122 4. Note 12 should include #4 cu. grounding electrode conductor to building steel per N.E.C. 250.66 5. Note 13 should read "(4) #3/0 cu." 6. Loads on transformer, Panel B, branch circuits, and load summary are inconsistent. 7. RTU -1 is 208 volt or 480 volt? a. Panel B denotes 3 pole 50 amp breaker (208 volt) b. Riser diagram (note 8) indicates 30 amp at 480 volt c. Power plan (note 4) indicates Panel H 1,3,5 VAV 3 pole 20 amp (480 volt) Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. •p IT COORD COPY � PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -463 DATE: 07 -11 -08 PROJECT NAME: SEATTLE TEAM SHOP KIDS SITE ADDRESS: 1057 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 2 After Permit Issued DEPARTMENTS: Bull ik Di ion Public Works U Fire Prevention Structural Planning Division ❑ Permit Coordinator u DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07 -17-08 Complete I vii Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS RQUTING: Please Route Structural Review Required REVIEWER'S INITIALS: nNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 08 -14 -08 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 IERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -463 DATE: 06 -13 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 1067 SOUTHCENTER MALL Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 After Permit Issued Original Plan Submittal DEPARTMENTS: AAit (0.149 in. 10 !vision r.�, Public Works Fire Prevention Structural Planning Division n Permit Coordinator n L_, DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06 -19-08 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: UNo further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: DUE DATE: 07 -17 -08 Approved with Conditions r Not Approved (attach comments) REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 PERMIT COORD COPY e PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -463 DATE: 05 -09 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 1067 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: 6-4 0). Ainitision Public Works Fire Prevention Structural Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete ❑ DUE DATE: 05-1 3-08 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 06-10 -08 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28-02 • • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -463 DATE: 04 -24 -08 PROJECT NAME: WESTFIELD VANILLA BOX SITE ADDRESS: 1067 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Bu Iding ivn q-D13 Fire Prevention Public Works ❑ Structural Planning Division Permit Coordinator ►_1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04 -29 -08 Complete Comments: Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ LETTER OF COMPLETENESS MAILED: Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05 -27 -08 Not Approved (attach comments) r/ DATE: Permit Center Use Only CORRECTION LETTER MAILED: t4 O Departments Issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 PROJECT NAME: Vc,,,\: \\ (A SITE ADDRESS: (o-j S -C - Mc., 41 ( PERMIT NO: t LO 8 �t (P3 ORIGINAL ISSUE DATE: S_15.0 g" REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS t 1 e t3- 0 - cam- (D--)-k--or _ IM( Summary of Revision: C e P �ve t,k„; utik v � € r \I C10 v.e 1 c k c L l,es 1� , �p ��sk■ ) -2 40 -e (4 v� 1 cin d i Received by: Received by: /%JQA1LJ //MA p , REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS t I �j� �f2 `1 -2-3 satc Summary of Revision: Summary of Revision: O e. T T - ra v ∎ r P Ct PE s S ti , Received by: l (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received b : (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received b : (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) • City of Tukwila Steven Al Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 7/// /o? ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 2— after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: EL-6F- -- 44.3 Project Name: sesl#/e refit.» 51719 1<"; Is Ct fi t r /. bues/-4'c 1/4ti, 114 X) Project Address: /4 S 7 VO k 1'% C e --. %-ate fl'i4 / Contact Person: �-e ; car1Q Phone Number: 8/ s--4/6 a.— 8, 2.3 Summary of Revision: .i reu.' S 4) c 4dal L 4 64 T /1 F r--Po e4Loiel i' // 4 rr, J,vz 11711A 4 1-- Me_ wa r /E.)- j a mate e_ ea.i c!i ch4 WDY Gier>1 e. b 7 vin,//4 au.li. 4.#i 7 Lack 'til Z y Gt i uet r- e 06o+r cv a y,f . ,c-r. 6ses (S4/.5 211 Slur-4r.2 ?c. JUL 112008 PER v.IT CENT 9 Soo Sheet Number(s): — J "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Flus on 1 —At-0g `applicattons'forns• applications on Iine \tevis;on submittal Created: 8- 13 -2C04 • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http : / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: , L O,' — 4.6.3 ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # / after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: W e6-1-4 e vet," // /`, 6 X Project Address: /o 6 7 6)z- Contact Person: Ma Pda// Phone Number: 214.- flD2 - 6 b7 / Summary of Revision: 6-i 45,5 .i d e L Re-e); 54 e /e-e. r�-� c �/Q a�.r - /7 /�., 1i y " fro- r Y i"e1C /e at" do /eJ« 71v lP/"oa fr e-zi se_ e /e-c_,4— c --:-40 ernmti —) lil5r ■ ry �7� Rio, t, hp� asp /a-:_is (� Rem; s1 /1.14 ,S Ie. G 41 -.� Lr k,r Sa/y7n7 aAr Sheet Number(s): -4 E - "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on te 1-0 X lepplications\fonns- applications on Iine\revision submittal Created: 8-13 -2004 REC 777: CITY OF ' • r. IJUN 1 3 2008 rERI*Fi —cr r - • • City of Tukwila Steven Al. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: ICLDB• - 44,-3 ❑ Response to Incomplete Letter # O Response to Correction Letter # ( RECEIVED CITY OF TI I1M1L.p ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: W Q 5 Pie ( t24 , 7 , lf' c X Project Address: le-) 67 & te >� At4 j 7-14 k i r /� � Iv» 9 kf &P Contact Person: t free/ 9 Fg_Dbi ,n'f Phone Number: eO 2_^ D7 / Summary of Revision: 6e c- j'ta.r ra. r`� 'e r 5� m, 5 �v e cQ MAY 0 9 2008 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all ar s of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on % i m [95 lapplicationslforms- applications on linelrevision submittal Created: 8-13 -2004 Look Up a Contractor, Electr or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SMEINS *066DB Licensee Name S M E INC OF SEATTLE Licensee Type ELECTRICAL CONTRACTOR UBI 601524252 Ind. Ins. Account Id Business Type CORPORATION Address 1 828 POPLAR PL S Address 2 City SEATTLE County KING State WA Zip 98144 Phone 2063292040 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/2/1994 Expiration Date 3/2/2010 Suspend Date Separation Date Parent Company Previous License Next License PACIFFS973PU Associated License BAKERJT973LR Master Electrician Information License BAKERJT973LR Name BAKER, JON T Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MARVICH, STEPHEN E 01/01/1980 PINSKY, ADAM A 01/01/1980 BAKER, JON T AGENT 01/01/1980 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= SMEINS *066DB 05/19/2008 ®4 PROVIDE AND INSTALL NEW 0 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW VAV UNIT. VITRIFY LOCATION IN FIELD. O NOT UISED PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.S. +10' -0" AFF 1057 Southcenter Mall Tukwila, WA 98188 15 1 �- F�U1S40�S No changes shall be mad e to P scope r v of of work without prior ap r val 'Tukwila Building plan submittal B will require a new plan submittal H + an may include additonal plan review 40 ,` 4�.� and may +10' -0"I IAFF 1725 westlake ave. n. suite 210 seattle, washington 981 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://vvvvvv.smithco.org/ Consultant FLOOR PLAN NOTES BY SYMBOL O VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. O INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 UNE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM. OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL. BE A MINIMUM SIZE OF #8 AWG THWN. O NOT USED TRICAL /P ER PLAN Pte' review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation Of any adopted code or ordinanto. Receipt approved Copyand cmditions is acknowledged: By, Date:, 917-* S City of Tukwila BUILDING DIVISION Consultant Registration Architect Registration LIGHT FIXTURE SCHEDULE PLAN MANUFACTURER MODEL MARK DESCRIPTION A COOPER /METALUX 2GA332A120VEB82 2'x4' LAY —IN FLUORESCENT, T8 ENERGY SAVING B U1HONIA 8W1 AZ INCANDESCENT RECESSED DOWNLIGHT, 8" 60 WATTS C COOPER/METALUX GA232A120VEB81 1'x4' LAY —IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL —LIGHT LXURWELED UTEFORM COLLECTION EXIT LIGHTS /BATTERY BACKUP X2 SURELITES CC7 EMERGENCY LIGH11NG /BULBS INCLUDED HUBBELL CSI221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120-277V—WHITE os> PASSIVE INFRARED AND U11UZE AS ADAPTIVE HUBBELL ATP1277W MICROPROCESSOR TO SELF ADJUST 11ME DELAY AND SENSITIVITY DS ULTRASONIC AND U11UZE AS ADAPTIVE �i HUBBELL ATU1277RRW MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY REGISTERED ARCHITECT �ICE171� 1• `SIGITh ■ STATE OF WASHINGTON Issues and Revisions No. Date Issues By Check 1 03.31.08 2 05.05.08 3 05.28.08 4 05.29.08 4 07.08.08 PERMIT PERMIT CORRECTIONS ISSUE CONSTRUCTION SET EGRESS SET KLS KLS KLS KLS KLS ■■NN■ Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description POWER /LIGHTING PLAN REdEIVED UL 112008 PERM CENTEF J Computer File CW05- 2008— E1,DWG Scale AS NOTED CTRICAL /LppHTING PLAN NOTE: PROVIDE 1 FC OF EMERGENY LIGHTING REQUIRED ALONG ENTIRE OF EGRESS MEASURED AT FiLOOR All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. Egos - 443 FLOOR PLAN NOTES BY SYMBOL O VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. O INSTALL A GROUND V1RE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 LINE. GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD 15 IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THWN. ONOT USED LIGHT FIXTURE SCHEDULE PLAN MARK MANUFACTURER MODEL $ DESCRIPTION A COOPER /METALUX 2GA332Al2OVE1382 2'x4' LAY -IN FLUORESCENT, T8 ENERGY SAVING B LITHONIA 6W1AZ INCANDESCENT RECESSED DOWNLIGHT, 8" 60 WATTS C COOPER/METAWX GA232A120VEBB1 1'x4' LAY -IN FLUORESCENT, TB ENERGY SAVING XT DUAL -LIGHT LXURWELED LITEFORM COLLECTION EXIT LIGHTS/BATTERY BACKUP X2 SUREUTES CC7 EMERGENCY LIGHTING /BULBS INCLUDED 4 HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -2774 -WHITE 40S1. HUBBELL ATP1277W PASSIVE INFRARED AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSIT1VITY r HUBBELL ATU1277RRW ULTRASONIC AND UTILIZE AS ADAPTIVE MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY 4 PROVIDE AND INSTALL NEW 30 AMP NEMA 31'y DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VL#RIFY LOCATION IN FIELD. n PROVIDE AND INSTALL NEW DISCONNECT A D ALL ASSOCIATED ELECTRICAL FROM PANEL TO �/ STOREFRONT SIGN PER N.E.C. +10' -0" AFF B 36 38 EP H 1,3,5 B 34 B B 32 30 ECTRICAL /POWER SCALE: 1/4" = 1' -0" -T 15 40 +10' -0" A PLAN PROVIDE 1 FC OF EMERGENCY LVGH11NG REQUIRED ALONG ENTIRE PATH OF EGRESS MEASURED AT FLOOR + 15-0" AFF F ■ ■■P1 ISE ■rA■■E■ NE MI ME ME ELECTRICAL /LIGHTING PLAN FILE, C e� Permit No. Rix- review approval is subject to errors and ins. Approval of construction documents does not aphorize the violation of any adopted code or ordinanw. Receipt of approved f eld Copy and editions is ad' W! d ed: 1067 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant By Date: City of itfitwila `lEti.Dl C fIS ON _ Consultant Registration RVIONED FOR CODE. COMPLIANCE NEC 1'UN `z a 2 City On Yukwila OWING ®NISIO% 6294 Architect Registration Issues and Revisions No. Date Issues By Check 1 03.31.08 2 05.08.08 3 05.26.08 PERMIT KLS PERMIT CORRECTIONS KLS TENANT REVISIONS KLS RE�11SloNS �M V i No changes shall be made to the score I of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review ;ees �i RECEIVED JUN 13 2008 PERMIT CENTER REVISION N0: ELo8'-i,3 Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description POWER /LIGHTING PLAN Computer File CW05- 2008— E1,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. Ilc. E -1 2 \EW PA \EL B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X -- — — SPACE 2 20,030 3 3 TRACK LIGHTING 1200 12 1/20 X -- -- — SPACE 4 1.2 3 5 TRACK LIGHTING 1200 12 1/20 1.25 X — — -- SPACE 6 X 3 7 SPACE — — X — — -- SPACE 8 X 3 9 SPACE — — — X 11 -- -- SPACE 10 X -- 11 SPACE -- — — X -- — -- SPACE 12 X -- 13 SPACE — — — X — — -.- SPACE 14 X 2 15 SIGN 1200 12 1/20 X -- — -- SPACE 16 X — 17 SPACE -- — — REMARKS TOTAL LOAD PHASE 'A' 21630 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61045 WATTS MANUFACTURERS RECOMMENDATION 170 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - OVIDE A LOCK -ON BREAKER NOTE: T. .C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS RE UIRED FOR NEW ELECTRICAL DEVICES. T.G. . TO BALANCE ALL PHASES TO WITHIN 10 %. * VERI EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON P EL OR LOAD PURPOSES ONLY. X -- — — SPACE 18 19 SPACE -- — — X -- — — SPACE 20 21 SPACE -- — — X -- — — SPACE 22 23 SPACE -- — — x -- — — SPACE 24 25 SPACE -- — — X -- — — SPACE 26 27 SPACE -- — -- X — — -- SPACE 28 29 SPACE -- — -- X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE — — -- X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE — — -- X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE — — -- X 1/20 12 1000 GENERAL RECEPTACLES 36 37 SPACE — — -- X 1/20 12 1000 GENERAL RECEPTACLES 38 39 SPACE — — -- X 1/20 12 1000 GENERAL RECEPTACLES 40 41 SPACE — — -- X — -- -- SPACE 42 REMARKS TOTAL LOAD PHASE 'A' 2710 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 4480 2- CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 3700 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 10450 WATTS MANUFACTURERS RECOMMENDATION 31 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. ELECTRICAL \ E W PA\EL ---- LOAD TYPE Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS - WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 2.8 1 FMB -1 1000 10 3/20 X 120 1/0 20,030 TRANSFORMER 2 N/A 4 4 1000 X 3/125 19,150 4 3 6 1.2 1.25 5 1000 1 X 17,165 1.25 7 SPACE -- — — X -- — -- SPACE 8 4 9 SPACE — — — X -- — -- SPACE 10 11 SPACE — — — X -- — -- SPACE 12 13 GENERAL LIGHTING 600 12 1/20 X -- -- -- SPACE 14 15 GENERAL LIGHTING 800 12 1/20 X — -- --. SPACE 16 17 GENERAL LIGHTING 300 12 1/20 X — -- — SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 21630 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61045 WATTS MANUFACTURERS RECOMMENDATION 170 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - OVIDE A LOCK -ON BREAKER NOTE: T. .C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS RE UIRED FOR NEW ELECTRICAL DEVICES. T.G. . TO BALANCE ALL PHASES TO WITHIN 10 %. * VERI EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON P EL OR LOAD PURPOSES ONLY. ELECTRICAL LOAD S, ARY 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK HHHHH • • OVERRIDE SWITCHES • SIGN LIGHTS (B15) • GENERAL LIGHTS (83) L____1 GENERAL LIGHTS (B15) GENERAL LIGHTS (B17) .LIGHT SWITCHING DETAIL Not To SCALE PA\EL R S E R D LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH 277/480V 3 PH, 4 WIRE ELECTRICAL SERVICE VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. LIGHTING 2.2 1.25 2.8 208 1 RECEPTACLES 7.2 1.00 7,2 120 1 WATER HEATER N/A 1.00 N/A 208 1 TRACK LIGHTING 2.4 1.25 3.0 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC .1 1.25 .125 120 1 HVAC 11.0 + 25 OF LARGEST LOAD 13.8 480 3 TOTALS: 24.1 28.4 KW = 23 6 AMPS © 120/208 SERVICE 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK HHHHH • • OVERRIDE SWITCHES • SIGN LIGHTS (B15) • GENERAL LIGHTS (83) L____1 GENERAL LIGHTS (B15) GENERAL LIGHTS (B17) .LIGHT SWITCHING DETAIL Not To SCALE PA\EL R S E R D I A G R A V RISER DIAGRAvI GENERAL NOTES 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN FIELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 277/480V 3 PH, 4 WIRE ELECTRICAL SERVICE VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. ® RI DIAGRAV NOTE • BOL ..R @ PROVIDE AND INSTA ' #1/O THWN . (1) •:. GROUND IN 2° CONDUIT FOR TEN SERVICE. ® PROVIDE AND INSTALL METER PER LOCAL U MY AND LOCAL AUTHORITY RECOMMENDATIO . ® PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. Co PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2° CONDUIT. ® PROVIDE AND INSTALL (4) #1/O THWN CU, (1) #6 GROUND IN 2° CONDUIT FOR PANEL 'H'. © PROVIDE AND INSTALL (3) #10 THWN CU, (1) #8 GROUND IN 3/4° CONDUIT FOR FMB -1 ; NOT USED 0$ PROVIDE AND INSTALL 30 AMP DISCONNECT FOR FMB -1 IN CEILING. VERIFY LOCATION IN FIELD. ®9 PROVIDE AND INSTALL (1) #4 CU, GROUNDING ELECTRODE CONDUCTOR TO BLDG. STEEL 10 NOT USED 11 PROVIDE AND INSTALL (3) #1/O THWN CU, IN 1 -1/4" CONDUIT FOR TRANSFORMER W /#6 CU GROUND PER NEC 250 -122 12 PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. @ PROVIDE AND INSTALL (4) #3/0 THWN CU, (1) #6 GROUND IN 2" CONDUIT FOR PANEL 'B'. PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS QUIRED ® 0 I I I J I I I PANEL H. I NEW PANEL B. 4 O 1 EXISTING ELECTRICAL I 1 ®O 1 DISTRIBUTION SYSTEM(S) 1 FOR OTHER TENANTS 1 1 (1) L J �T' EXISTING LANDLORD WIREWAY ® I Q FLOOR LANDLORD TENANT PROVIDE AND INSTALL GROUND TO BUILDING STEEL PER N.E.. • • 1067 Southcenter Mall Tukwila, WA 98188 smitite*. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Architect Registration 6294 Issues and Revisions No. Date Issues By Check 1 03.31.08 PERMIT KLS 2 05.08.08 PERMIT CORRECTIONS KLS 3 05.26.08 TENANT REVISIONS KLS 4p_ �°20 i ;� j� �, u 2a�8 atv 43i WO* DDI RECEIVED JUN 13 Z. PERMIT COM I II Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description PANELSCHEDULES Computer File CW05- 2008— E2.DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -2 4 PROVIDE AND INSTALL NEW 30 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. 0 PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.E.C. .f14' --.3" REF 1067 Southcenter Mall Tukwila, WA 98188 smith c*. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://wvvw.smithco.org/ Consultant FLOOR PLAN NOTES BY SYMBOL ✓ VERIFY MOUNTING HEIGHTS AND REQUIREMENTS PRIOR TO INSTALLATION OF ANY RECEPTACLES. O INSTALL A GROUND WIRE AND LUG TO THE BACKBOARD FOR THE PURPOSE OF PROVIDING GROUND PROTECTION FOR EQUIPMENT CONNECTED TO THE T -1 IJNE GROUND SHOULD BE RUN DIRECTLY TO THE BACKBOARD FROM A GROUND ROD LOCATED IN THE WAN ROOM, OR IF INSTALLATION OF A GROUND ROD IS IMPRACTICABLE DUE TO LOCATION, GROUND WIRE SHALL BE RUN DIRECTLY TO THE BACKBOARD FROM THE NEAREST ELECTRICAL SUB PANEL OR TRANSFORMER GROUND LUG. GROUND WIRE SHALL BE A MINIMUM SIZE OF #8 AWG THWN. O NOT USED • PROVIDE AND INSTALL NEW 60 AMP NEMA 3R DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW ROOF TOP UNIT ON ROOF. VERIFY LOCATION IN FIELD. O PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO NEW WATER HEATER ABOVE CEILING. VERIFY LOCATION IN FIELD. ✓ PROVIDE AND INSTALL NEW DISCONNECT AND ALL ASSOCIATED ELECTRICAL FROM PANEL TO STOREFRONT SIGN PER N.EC. ECTRICAL /POWER SCALE: 1 /4" = 1' -0" Consultant Registration Architect Registration LIGHT FIXTURE SCHEDULE PLAN MANUFACTURER MODEL DESCRIPTION MARK A COOPER /METALUX 2GA332A120VE882 2'x4' LAY —IN FLUORESCENT, T8 ENERGY SAVING B UTHONIA 8W1AZ INCANDESCENT RECESSED DOWNUGHT, 8' 60 WATTS C COOPER/METALUX GA232Al2OVEBB1 1'x4' LAY —IN FLUORESCENT, T8 ENERGY SAVING X1 DUAL —LIGHT LXURWELED UTEFORM COLLECTION EXIT LIGHTS /BAIIU Y BACKUP X2 SUREIITES CC7 EMERGENCY UCHIING /BULBS INCLUDED HUBBELL CS1221W SINGLE POLE HEAVY DUTY TOGGLE SWITCH. 20A 120 -277V —WHITE psi PASSIVE INFRARED AND UTILIZE AS ADAPTIVE HUBBELL ATP1277W MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY ii- ULTRASONIC AND UTILIZE AS ADAPTIVE HUBBELL ATU1277RRW MICROPROCESSOR TO SELF ADJUST TIME DELAY AND SENSITIVITY REGISTERED ARCHWECT -KM?! L. "SIBITFI STATE OF WASHINGTON NOTE: PROVIDE 1 FC OF EMERGENCY LIGHTING REQUIRED ALONG ENTIRE PATH OF EGRESS MEASURED AT FLOOR Issues and Revisions No. Date Issues By Check 1 03.31.08 2 05.08.08 PERMIT KLS PERMIT CORRECTIONS KLS i ■.0P Plar review approval Is subject to errot5 and moons. Approval of construction documents does not aithorize the violation of any adopted code or ordinance. Receipt of approved RI Copy and co cans is aged: B t (160 h `t Date:, 3h9 \05 City of Tukwila BUILDING DIVISION X2 % i ME ME ISO 0 0 EMMMIEll MIME. EMMEN REVISIONS No changes shall be made to the scope I of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees; RECEIVED v nr rt IVUA CORRECTION LTR# PERMIT CENTER Project Name WESTFIELD SOUTHCENTER MALL SEPARATE PERMIT REQUIRED FOR: Mechanical D Electrical Plumbing tVGas Piping City of Tukwila BUILDING DIVISION ELECTRICAL /LIGHTING PLAN SCALE: 1 /4" = 1' -0" Project Number 02008018.00 Description POWER /LIGHTING PLAN Computer File CW05- 2008— E1.DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. Ile and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co, Ilc. \FW PA\-L B Service: 120/208 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 200 Total Watts: 34,174 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM 6 1 EXIT /NIGHT LIGHTING 450 12 1/20 X 1/20 12 100 EF1 2 WATER HEATER 3 3 SPACE -- - - X -- - -- SPACE 4 17,165 3 5 SPACE -- - - - X -- - -- SPACE 6 -- 3 7 SPACE -- - SPACE X - - -- SPACE 8 -- 3 9 SPACE -- - - X - - -- SPACE 10 -- SPACE 11 WATER HEATER 750 12 2/20 600 X - - -- SPACE 12 -- X - - SPACE 14 800 12 13 750 2 15 SIGN 1200 12 1/20 X -- w- -- SPACE 16 X - 17 SPACE -- - -- REMARKS TOTAL LOAD PHASE 'A' 21630 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61045 WATTS MANUFACTURERS RECOMMENDATION 170 AMPS 5 - PROVIDE H.A.C.R. BREAKER - OVIDE A LOCK -ON BREAKER NOTE: T. .C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS RE UIRED FOR NEW ELECTRICAL DEVICES. T.G. . TO BALANCE ALL PHASES TO WITHIN 10 %. * VERI EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON P EL OR LOAD PURPOSES ONLY. X - - -- SPACE 18 19 SPACE -- - -- X -.. -- SPACE 20 21 SPACE -- - -- X - - -- SPACE 22 23 SPACE -- - -- x - - -- SPACE 24 25 SPACE -- - -- X -- •-- -- SPACE 26 27 SPACE -- - -- X 1/20 12 360 GFI RECEPTACLES 28 29 SPACE -- - -- X 1/20 12 1500 GENERAL RECEPTACLES 30 31 SPACE -- -- -- X 1/20 12 1260 GENERAL RECEPTACLES 32 33 SPACE -- - -- X 1/20 12 1080 GENERAL RECEPTACLES 34 35 SPACE -- - -- X 1/20 12 1000 GENERAL RECEPTACLES 36 37 SPACE -- - - X 1/20 12 1000 GENERAL RECEPTACLES 38 39 SPACE -- -- X 1/20 12 1000 GENERAL RECEPTACLES 40 41 SPACE -- - -- X -- - - SPACE 42 REMARKS TOTAL LOAD PHASE 'A' 3560 1- PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 3640 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 3250 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 10450 WATTS MANUFACTURERS RECOMMENDATION 30 AMPS 5 - PROVIDE H.A.C.R. BREAKER 6 - PROVIDE A LOCK -ON BREAKER NOTE: T.G.C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS REQUIRED FOR NEW ELECTRICAL DEVICES. T.G.C. TO BALANCE ALL PHASES TO WITHIN 10 %. * VERIFY EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON PANEL FOR LOAD PURPOSES ONLY. \EW PANEL H Service: 277/480 Volts 3 Phase 4 Wire Cabinets: Surface Mounted Mains: 200 Amp Main Circuit Breaker 125 Total Watts: 71,345 NEMA 1 REM CKT DESCRIPTION WATTS WIRE BKR A B C BKR WIRE WATTS DESCRIPTION CKT REM LIGHTING 1 FMB -1 1000 10 3/20 X 7.2 1/0 20,030 TRANSFORMER 2 WATER HEATER X 3/125 19,150 4 4 4 3 1000 N/A 5 1 X 17,165 6 1.5 1000 1 7 SPACE - -- - X - -- -- SPACE 8 3 4 9 SPACE - - - X -- -- -- SPACE 10 11 SPACE - - - X -- -- -- SPACE 12 13 GENERAL LIGHTING 600 12 1/20 X - -- -- SPACE 14 15 GENERAL LIGHTING 800 12 1/20 X -- -- SPACE 16 17 GENERAL LIGHTING 300 12 1/20 X - -- - SPACE 18 REMARKS TOTAL LOAD PHASE 'A' 21630 1 - PROVIDE GFCI BREAKER TOTAL LOAD PHASE 'B' 20950 2 - CIRCUIT VIA TIME CLOCK TOTAL LOAD PHASE 'C' 18465 3 - CIRCUIT VIA CONTACTOR 4 - PROVIDE BREAKER AND FUSES PER EQUIPMENT TOTAL LOAD ALL PHASES 61045 WATTS MANUFACTURERS RECOMMENDATION 170 AMPS 5 - PROVIDE H.A.C.R. BREAKER - OVIDE A LOCK -ON BREAKER NOTE: T. .C. SHALL PROVIDE NEW BREAKERS, FEEDERS AND CONDUIT AS RE UIRED FOR NEW ELECTRICAL DEVICES. T.G. . TO BALANCE ALL PHASES TO WITHIN 10 %. * VERI EXACT EXISTING CIRCUIT(S) NUMBER IN FIELD. SHOWN ON P EL OR LOAD PURPOSES ONLY. -- LFCTRICAL LOA SJv v ARY 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK DEIDHHIR OVERRIDE SWITCHES 'b' SIGN LIGHTS (B15) GENERAL LIGHTS (B3) GENERAL LIGHTS (815) L____1 J)LIGHT SWITCHING DETAIL NOT TO SCALE GENERAL LIGHTS (817) P A \- L RS- R DIAGRAy LOAD TYPE CONNECTED KW FACTOR DEMAND KW VOLTAGE PH VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. C--- LIGHTING 2.2 1.25 2.8 208 1 RECEPTACLES 7.2 1.00 7.2 120 1 WATER HEATER 1.5 1.00 1.5 208 1 MISCELLANEOUS N/A 1.00 N/A 120 1 SIGN 1.2 1.25 1.5 120 1 SUPPLEMENTAL HVAC .1 1.25 .125 120 1 HVAC 11.0 + 25 OF LARGEST LOAD 13.8 480 3 TOTALS: 23.2 26.9 KW - 32 3 AMPS © 120/208 SERVICE 120 VOLT CIRCUIT REFER TO RISER DIAGRAM FOR TIMECLOCK AND CONTACTORS LANDLORD SPECIFICATIONS TIME CLOCK DEIDHHIR OVERRIDE SWITCHES 'b' SIGN LIGHTS (B15) GENERAL LIGHTS (B3) GENERAL LIGHTS (815) L____1 J)LIGHT SWITCHING DETAIL NOT TO SCALE GENERAL LIGHTS (817) P A \- L RS- R DIAGRAy RISER DIAGRAM GENERAL NOTES 1. TENANT'S GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL COPPER CONDUCTORS. 2. VERIFY ALL EXISTING CONDITIONS IN HELD. ALL UPGRADES REQUIRED BY CODES, LANDLORD OR TENANT SHALL BE BY TENANT AT TENANTS EXPENSE. 3. ALL WIRING SHALL BE IN CONDUIT E.M.T. OR RIGID. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTION, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED CABLE, ETC ALLOWED. 0V 3 PH, 4 WIRE 4 WIRE ELECTRICAL SERVICE I VERIFY EXISTING CONDITIONS AND REQUIREMENTS PRIOR TO BIDDING AND INSTALLATION. C--- _1® RI R DIAGRAM NOTE : BOL ® PROVIDE AND INSTA #1/o THWN . (1) • =. GROUND IN 2" CONDUIT FOR TENA ' SERVICE. (®�_ 0 r 1 I 0 ® PROVIDE AND INSTALL METER PER LOCAL U UTY AND LOCAL AUTHORITY RECOMMENDAIIO -. O PROVIDE AND INSTALL 200 AMP DISCONNECT FUSED AT 125 AMPS FOR TENANT SERVICE. VERIFY LOCATION IN FIELD. ® PROVIDE AND INSTALL (4) #1 /O THWN CU, (1) #6 GROUND IN LANDLORD PROVIDED 2° CONDUIT. ® PROVIDE AND INSTALL (4) #1/0 THWN CU, (1) #6 GROUND IN 2° CONDUIT FOR PANEL 'H'. ® PROVIDE AND INSTALL (3) #10 THWN CU, (1) 0 GROUND IN 3/4° CONDUIT FOR RTU -1 ON ROOF. O NOT USED $ PROVIDE AND INSTALL 30 AMP DISCONNECT FOR FMB -1 IN CEIUNG. VERIFY LOCATION IN FIELD. O PROVIDE AND INSTALL (1) #4 CU, GROUNDING ELECTRODE CONDUCTOR TO BLDG. STEEL 10 NOT USED 11 PROVIDE AND INSTALL (3) #1/O THWN CU, IN 1 -1/4° CONDUIT FOR TRANSFORMER W /#6 CU GROUND PER NEC 250 -122 g 1C PROVIDE AND INSTALL A 75 KVA FLOOR MOUNTED TRANSFORMER. 13 PROVIDE AND INSTALL (4) #3/0 THWN CU, (1) 0 GROUND IN 2° CONDUIT FOR PANEL 'A'. PROVIDE AND INSTALL 24 HR, 7 DAY TIMECLOCK FOR SHOW WINDOW AND SIGNAGE. PROVIDE NEW AS QUIRED .AL I I EXISTING ELECTRICAL I l NEW PANEL NEW PANEL — 14 O ®0 DISTRIBUTION SYSTEM(S) 1 FOR OTHER TENANTS I I LJ EXISTING LANDLORD WIREWAY I 1, ® ® 12 FLOOR LANDLORD TENANT FJ PROVIDE AND INSTALL — GROUND TO BUILDING 51EEL PER N.E.. 1067 Southcenter Mall Tukwila, WA 98188 smith c*. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http: / /www.smithco.org/ Consultant Consultant Registration Architect Registration 6294 Issues and Revisions No. Date Issues By Check 1 03.31.08 PERMIT KLS 2 05.08.08 PERMIT CORRECTIONS KLS RECFiVFD CITY OF TUKWII A MAY 0 9 2008 PERMIT CENTER Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018,00 Description PANELSCHEDULES Computer File CW05- 2008— E2,DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. E -2 PART 1 - GENERAL 1.01 SCOPE OF WORK: FURNISH AND INSTALL ALL EQUIPMENT AND EQUIPMENT AND PROVIDE ALL LABOR, TOOLS, TRANSPORTATION, SUPERINTENDENT AND SERVICES REQUIRED AND NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS AND /OR SPECIFIED HEREIN. ALSO ARE INCLUDED ALL OTHER WORK AND MISCELLANEOUS ITEMS, NOT SPECIFICALLY MENTIONED BUT REASONABLY INFERRED FOR A COMPLETE INSTALLATION INCLUDING ALL ACCESSORIES AND APPURTENANCE REQUIRED FOR TESTING THE SYSTEM. IT IS THE INTENT OF THE DRAWING AND SPECIFICATIONS THAT ALL SYSTEMS BE COMPLETE AND READY FOR OPERATION. 1.02 REGULATORY REQUIREMENTS CODE COMPLIANCE IS MANDATORY. NOTHING IN THESE DRAWINGS AND SPECIFICATIONS PERMITS WORK AND NOT CONFORMING TO THESE CODES. WHERE WORK IS SHOWN TO EXCEED MINIMUM CODE REQUIREMENTS, COMPLY WITH DRAWINGS AND SPECIFICATIONS. ALL WORK AND MATERIALS SHALL COMPLY WITH THE LATEST RULES, CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING: 1. OCCUPATIONAL SAFETY AND HEALTH ACT STANDARDS (OSH). 2. NFPA #70; NATIONAL ELECTRIC CODE (NEC). 3. NFPA #101: LIFE SAFELY CODE. 4, STATE FIRE MARSHAL. 5. LOCAL UTILITIES COMPANIES. 6. ALL LANDLORD GENERAL REQUIREMENTS FOR MALL. 1.03 LICENSE. FEES AND PERMITS: ELECTRICAL CONTRACTOR SHALL PAY FOR ALL LICENSES, PERMITS AND INSPECTION FEES REQUIRED BY THE AUTHORITY HAVING JURISDICTION AND SHALL ARRANGE FOR ALL REQUIRED INSPECTIONS. 1.04 SAFETY AND INDEMNITY: THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. NO ACT, SERVICE, DRAWING REVIEW OR CONSTRUCTION REVIEW BY THE OWNER, THE ENGINEERS OR THEIR CONSULTANTS, IS INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, ON, OR NEAR THE CONSTRUCTION SITE. 1.05 DRAWINGS AND SPECIFICATIONS: ALL DRAWINGS AND ALL DIVISIONS OF THESE SPECIFICATIONS SHALL BE CONSIDERED AS A WHOLE AND WORK OF THIS DIVISION SHOW ANYWHERE THEREIN SHALL BE FURNISHED UNDER THIS DIVISION. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF EQUIPMENT AND WIRING. MOST DIRECT ROUTING OF CONDUITS AND WIRING IS NOT ASSURED. EXACT REQUIREMENTS SHALL BE GOVERNED BY CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS, WHETHER SPECIFICALLY MENTIONED OR NOT. 1.06 CONDITIONS AT SITE: THE ELECTRICAL CONTRACTOR SHALL HAVE EXAMINED THE SITE AND FAMILIARIZED THEMSELVES WITH ALL DISCERNIBLE EXISTING CONDITIONS. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK REQUIRED BECAUSE OF THESE CONDITIONS SHALL BE INCLUDED IN THE BID. 1.07 WORKMANSHIP AND CONTRACTOR'S QUALIFICATIONS: ONLY QUALITY WORKMANSHIP WILL BE ACCEPTED. HAPHAZARD OR POOR INSTALLATION WILL BE CAUSE FOR REJECTION OF WORK. THE CONTRACTOR SHALL BE A LICENSED MASTERED ELECTRICIAN OF THE STATE IN WHICH THE JOB 15 LOCATED. 1.08 SHOP DRAWINGS AND MATERIALS LISTS: SUBMIT TO OWNER IN A SINGLE PACKAGE SIX (6) COPIES OF COMPLETE SHOP DRAWINGS AND MATERIALS LISTS, AS NOTED BELOW, FOR REVIEW WITHIN FIFTEEN (15) DAYS AFTER AWARD OF CONTRACT. SUBMITTALS REQUIRED AS FOLLOWS. 1. WIRING DEVICES: SWITCHES, RECEPTACLES, DEVICE PLATES. 2. ENCLOSURES FOR UTILITY COMPANY METERING. 3. MAIN FUSED DISCONNECT SWITCH. 4. PANELBOARDS 5. DISCONNECT SWITCHES 6. LIGHT FIXTURES, LAMPS AND LIGHTING CONTROL EQUIPMENT. 1.09 SUBSTITUTIONS: ONE OF MORE MAKES OF MATERIALS OR METHODS MAY HAVE BEEN SPECIFIED TO ESTABLISH THE STANDARD OF QUALITY, WORKMANSHIP, FINISH AND DESIGN REQUIRED, BUT OTHER MATERIALS OR METHODS EQUAL IN QUALITY, WORKMANSHIP, FINISH, DESIGN, AND GUARANTEED PERFORMANCE, WILL BE ACCEPTED. HOWEVER, ALL CHANGES AND SUBSTITUTIONS SHALL BE REQUESTED IN LETTER FORM AND SHALL BE ACCOMPANIED WITH A STATEMENT OF THE AMOUNT OF MONEY TO BE RETURNED TO THE CONTRACT IF THE SUBSTITUTION 15 PERMITTED. NO WORK INVOLVING MATERIALS SUBMITTED FOR SUBSTITUTION SHALL PROCEED UNTIL WRITTEN ACCEPTANCE IS RECEIVED FROM THE OWNER. THE OWNER 15 THE SOLE JUDGE OF ACCEPTABILITY OF PREFERRED SUBSTITUTIONS. IF A SUBSTITUTION ITEM IS PERMITTED, AND ANY RE- DESIGN EFFORT IS THEREBY NECESSITATED, THE REQUIRED RE- DESIGN SHALL BE AT THE CONTRACTOR'S EXPENSE. 1.10 COORDINATION: COORDINATE WORK WITH OTHER TRADES TO AVOID CONFLICT AND TO PROVIDE CORRECT ROUGH -IN AND CONNECTION FOR EQUIPMENT FURNISHED UNDER OTHER TRADES THAT REQUIRED ELECTRICAL CONNECTIONS. INFORM CONTRACTORS OF OTHER TRADES THAT REQUIRE ACCESS TO AND CLEARANCES AROUND ELECTRICAL EQUIPMENT TO MAINTAIN SERVICE ABILITY AND CODE COMPLIANCE. VERIFY EQUIPMENT DIMENSIONS AND REQUIREMENTS WITH PROVISIONS SPECIFIED UNDER THIS SECTION. CHECK ACTUAL JOB CONDITIONS BEFORE FABRICATING WORK. REPORT NECESSARY CHANGES IN TIME TO PREVENT NEEDLESS WORK. CHANGES OR ADDITIONS, SUBJECT TO ADDITIONAL COMPENSATION, WHICH ARE MADE WITHOUT WRITTEN AUTHORIZATION AND AN AGREED PRICE, SHALL BE AT THE CONTRACTOR'S RISK AND EXPENSE. 1.11 CUTTING AND PATCHING: ALL CUTTING AND PATCHING REQUIRED FOR WORK OF THIS DIVISION 15 INCLUDED HEREIN. COORDINATION WITH GENERAL CONTRACTOR AND OTHER TRADES 15 IMPERATIVE. CONTRACTOR SHALL BEAR THE RESPONSIBILITY FOR AND THE ADDED EXPENSE OF ADJUSTING FOR IMPROPER HOLES, SUPPORTS, ETC. 1.12 ACCEPTANCE DEMONSTRATION: UPON COMPLETION OF THE WORK, AT A TIME TO BE DESIGNATED BY THE OWNER, THE CONTRACTOR SHALL DEMONSTRATE FOR OWNER THE OPERATION OF THE ELECTRICAL INSTALLATION, INCLUDING ANY AND ALL SPECIAL ITEMS INSTALLED BY HIM OR INSTALLED UNDER HIS SUPERVISION. PROPERTY SET AUTOMATIC TIME SWITCHES TO PERFORM SWITCHING OPERATIONS IN ACCORDANCE WITH SCHEDULES PROVIDED BY THE OWNER'S REPRESENTATIVE, AND DEMONSTRATE (USING THE MANUFACTURER'S OPERATING INSTRUCTIONS) HOW TO OVERRIDE AND /OR TEST TIME SWITCHES PROGRAMMING. 1.13 RECORD DRAWINGS, EQUIPMENT DATA: MAINTAIN ONE SET OF CLEAN WORKING DRAWINGS AT THE JOB SITE AND ENTER DAILY SUCH AS -BUILT INFORMATION AS FEEDER AND SERVICE ROUTES, PULL BOX LOCATIONS AND CHANGES IN LAYOUT OR ARRANGEMENT WHICH OCCUR DURING CONSTRUCTION. DELIVER COMPLETED DRAWINGS TO THE OWNER. DELIVER TO THE OWNER'S REPRESENTATIVE THREE COPIES OF DATA SHEETS OR OTHER CURRENT MANUFACTURERS PUBLICATIONS FOR EACH ITEM OF ELECTRICAL EQUIPMENT FURNISHED FOR THE PROJECT INCLUDING AT LEAST THESE DATA: 1. TECHNICAL DESCRIPTION AND REPLACEABLE PARTS LIST. 2. PHYSICAL DESCRIPTION AND INSTALLATION INSTRUCTIONS. 3. USER'S MANUAL AND OPERATING INSTRUCTIONS. 4. MANUFACTURER'S WARRANTY. 1.14 CLEANUP RID THE PREMISES OF SCRAP MATERIALS, TRASH AND DEBRIS BOTH DURING CONSTRUCTION AND AT COMPLETION OF THE PROJECT. LEAVE THE BUILDING AND SURROUNDING AREA IN A CLEAN AND ORDERLY CONDITION. 1.15 GUARANTEE: GUARANTEE THE INSTALLATION FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE YEAR AFTER DATE OF CERTIFICATION OF FINAL PAYMENT AND PROMPTLY REMEDY ANY DEFECTS DEVELOPING DURING THIS PERIOD, WITHOUT CHANGE. 1.16 TEMPORARY SERVICES: PROVIDE ADEQUATE AND SAFE TEMPORARY ELECTRICAL POWER AND LIGHTING THROUGHOUT THE CONSTRUCTION AND FINISHING OF THE PREMISES FOR BENEFICIAL OCCUPANCY. IN ADDITION TO SPECIAL OR UNUSUAL REQUIREMENTS, PROVIDE AT LEAST THESE ITEMS: 1. THREE 20 -AMP CIRCUITS FOR CONSTRUCTION POWER TOOLS. PROVIDE GFI TEMPORARY CIRCUITS WITH COVERPLATES TO MEET OSHA REQUIREMENTS. 2. THREE OR MORE LIGHT STRINGS SUSPENDED APPROXIMATELY ONE FOOT BELOW THE HEIGHT OF FINISH CEILING WITH LAMPS SPACED NOT MORE THAN TWELVE FEET ON CENTERS. STRINGS SHALL BE RUN THE LENGTH OF THE STORE SPACE PARALLEL TO THE DEMISING WALLS, WITH ONE STRING WITHIN EIGHT FEET OF EACH WALL AND ONE (OR MORE) INTERMEDIATE STRING(S) ARRANGED TO LIMIT THE SPACING BETWEEN ROWS TO SIXTEEN FEET OR LESS. 3. FLOOD LIGHTING AND TASK UGHTING FOR PAINTING AND OTHER FINISH WORK. WHEN PERMANENT ELECTRICAL SERVICE IS OPERABLE, DISCONNECT AND REMOVE FROM THE PREMISES THE MATERIALS AND EQUIPMENT USED FOR TEMPORARY POWER AND LIGHTING, AND RESTORE MODIFICATIONS AND REPAIR DAMAGE CAUSED BY THE INSTALLATION, USE OR REMOVAL OF TEMPORARY SERVICE PROVISIONS. 1.17 OWNER- FURNISHED ITEMS: CONTRACTOR SHALL INSTALL, CONNECT AND COMPLETE THE FOLLOWING ITEMS FURNISHED BY THE OWNER AND SHALL PROVIDE WIRES, CABLES, CONNECTORS, PIGTAILS, CORDS AND CORD -CAPS, BOXES, CONDUIT, PLATES, SUPPORTS, AND. OPERATING TESTS TO MAKE COMPONENTS AND SYSTEMS OPERATE SATISFACTORILY. PROVIDE SYSTEMS DRAWING FROM THE MANUFACTURER THROUGH THE OWNER IN ORDER TO INSTALL COMPLETE OPERABLE SYSTEM. 1. MUSIC SOUND SYSTEM COMPONENTS. 2. ENTRY ALARM SYSTEM CONTROL PANEL AND CONTACTS /SECURITY SYSTEMS. PART 2 - PRODUCTS 2.01 MATERIAL APPROVAL ALL MATERIALS MUST BE NEW AND BEAR UNDERWRITERS LABORATORIES LABEL. MATERIALS THAT ARE NOT COVERED BY UL TESTING STANDARDS SHALL BE TESTED AND APPROVED BY AN INDEPENDENT TESTING LABORATORY OR A GOVERNMENTAL AGENCY. MATERIAL NOT IN ACCORDANCE WITH THESE SPECIFICATIONS MAY BE REJECTED EITHER BEFORE OR AFTER INSTALLATION. 2.02 CONDUITS AND OTHER RACEWAYS: A. RIGID STEEL: HOT- DIPPED GALVANIZED. B. INTERMEDIATE METAL CONDUIT (IMC): HOT- DIPPED GALVANIZED C. ELECTRICAL METALLIC TUBING (EMT): ELECTRO- GALVANIZED. D. WIREWAY CODE GAUGE STEEL, WITH KNOCKOUTS AND HINGED COVER, CORROSION RESISTANT GRAY BAKED ENAMEL FINISH. E. PROVIDE FITTINGS AND ACCESSORIES APPROVED FOR THE PURPOSE EQUAL IN ALL RESPECTS TO THE CONDUIT OR RACEWAY. EMT CONNECTORS AND COUPLINGS SHALL BE STEEL SETSCREW TYPE INDOORS AND STEEL COMPRESSION TYPE IN WET LOCATIONS AND OUTDOORS. 2.03 WIRES AND CABLES: A. FOR POWER AND LIGHTING SYSTEM 600V OR LESS: 1. CONDUCTOR: MINIMUM SIZE #12 . A. #12 AND #10 AWG SOLID COPPER. B. #8 AWG AND LARGER SHALL BE STRANDED COPPER. 2. INSULATION TYPE: A. #12 TO #1 AWG: THWN FOR WET OR UNDERGROUND AND THWN FOR DRY LOCATIONS. B. #10 THROUGH #4/0 AWG: XHHW (55 MILS). C. #250 MCM AND LARGER XHHW (65 MILS). D. GROUNDING WIRE: TW. B. FOR SIGNAL AND COMMUNICATIONS CIRCUIT: 1. SPECIAL CABLES SHALL BE AS SPECIFIED ON DRAWINGS. 2. CONDUCTORS FOR GENERAL USE SHALL BE STRANDED COPPER CONDUCTOR, #16 AWG MINIMUM, WITH THWN INSULATION FOR UNDERGROUND OR WET LOCATIONS AND THHN INSULATION FOR DRY LOCATIONS. C. ACCEPTABLE PRODUCTS GENERAL ELECTRIC, ANACONDA, OKONITE, PARANITE OR TRIANGLE PRODUCTS CONFORMING OR EXCEEDING APPLICABLE IPCEA STANDARDS. 2.04 OUTLET BOXES, JUNCTION AND PULL BOXES: A. OUTLET BOXES: 4" SQUARE X 1 - I/2" DEEP (OR LARGER) GALVANIZED SHEET STEEL KO -TYPE WITH PLASTER RING AND COVER FOR GENERAL INTERIOR USE AND CAST METAL TYPE FS OR FD WITH MATCHING SCREW COVERS FOR EXTERIOR AND EXPOSED INTERIOR LOCATIONS (GASKETED IN DAMP OR WET LOCATIONS). B. JUNCTION BOXES SHALL BE SAME AS OUTLET BOXES UP TO 42 CU. IN. AND CODE- GAUGE STEEL IN LARGER SIZES WITH SURFACE OR FLUSH -TYPE SCREW- MOUNTED TRIM COVERS, BOTH BOXES AND COVERS INHIBITOR- PRIMED AND PAINTED INSIDE OUT. C. PULL BOXES SHALL BE SAME AS JUNCTION BOXES UNLESS INDICATED OTHERWISE ON THE DRAWINGS, WITH COVERS. D. TELEPHONE OUTLET BOXES SHALL BE THE TYPE AND SIZE REQUIRED BY THE SERVING TELEPHONE COMPANY BUT NOT SMALLER THAN 4- 11/16" SQUARE X 2 -1/8" DEEP WITH SINGLE -GANG RING AND SIERRA #S -754N SPLIT PLATE BUSHING. E. ALL BOXES AND ASSOCIATED COMPONENTS SHALL BE STEEL CITY 683 SERIES, WITH P60 -3B COVERPLATE. 2.05 WIRING DEVICES AND PLATES: WIRING DEVICES AND PLATES SHALL BE HUBBELL. ARROW HART, GE OR P &S WITH HUBBELL NUMBERS USED TO SPECIFY TYPE USED. STANDARD DESIGN: A. SWITCH AND RECEPTACLES DEVICES SHALL BE IVORY EXCEPT WHEN THE DEVICE IS LOCATED ORE A PURPLE WALL, WHEN ON PURPLE WAIL DEVICE SHALL BE BLACK B. ISOLATED GROUND RECEPTACLES SHALL BE WHITE WITH ORANGE TRIANGLE AS REQUIRED PER NEC, MANUFACTURED BY LEVITON # 5362 -IGW OR APPROVED EQUAL. C. SWITCHES SHALL BE 20 AMP, 120/277 VOLT A.C. RATED SINGLE POLE SWITCHES SHALL BE #1221 AND .3-WAY SWITCHES SHALL BE #1223. D. RECEPTACLES SHALL BE GROUNDING TYPE #5362. 2.06 CONDUIT HANGERS: FOR INDIVIDUAL CONDUIT RUNS NOT DIRECTLY FASTENED TO THE STRUCTURE, USE ROD HANGERS MANUFACTURED BY CADDY, UNISTRUT OR POWERSTRUT, FOR MULTIPLE CONDUIT RUNS, USE UNISTRUT OR POWERSTRUT TRAPEZE TYPE CONDUIT SUPPORT DESIGNED FOR MAXIMUM DEFLECTION NOT GREATER THAN 1/8" 2.07 WIRE CONNECTORS: FOR WIRE SIZES #8 AWG AND SMALLER INSULATED PRESSURE TYPE (WITH LIVE SPRING) RATED 105 DEGREES C. 600V, FOR BUILDING WIRING AND 1000W IN SIGNS OR FIXTURES, SCOTCHLOK OR IDEAL. FOR WIRE SIZE #6 AWG AND LARGER T & B OR EQUIVALENT COMPRESSION TYPE WITH 3M #33 OR PLYMOUTH "SLIPKNOT GRAY" TAPE INSULATION. 2.08 PANELBOARD: A. CONSTRUCTION: CABINETS SHALL BE OF CODE GAUGE, GALVANIZED STEEL, SURFACE OR FLUSH MOUNTED AS INDICATED. DOORS SHALL BE OF COLD - ROLLED STEEL WITH CONCEALED HINGES AND FLUSH CATCH AND LOCK. ALL PANELS SHALL BE KEYED ALIKE. PANELS LOCATED ADJACENT TO EACH OTHER SHALL HAVE IDENTICALLY SIZED ENCLOSURE AND TRIMS. MINIMUM PANEL WIDTH SHALL BE 20 ". FINISH EXPOSED PART WITH ONE COAT OF PRIMER AND ONE COAT OF LIGHT GRAY ENAMEL SUITABLE FOR OVER PAINTING IN FIELD IT DESIRED. B. BUS BARS: PROVIDE GROUND BLOCK WITH FULL COMPLEMENT OF TERMINALS IN ADDITION TO INSULATED NEUTRAL BUS. FUTURE BREAKER SPACES SHALL HAVE COMPLETE PROVISION INCLUDING BUSSES AIR CONNECTING HARDWARE. C. MANUFACTURER PANELBOARD SHALL IN GENERAL ELECTRIC TYPE AQ OR TYPE AE OR EQUIVALENT PRODUCTS OF CUTTER- HAMMER, SQUARE D, OR SIEMENS -ITE. D. CIRCUIT BREAKERS SHALL BE BOLT -ON, THERMAL- MAGNETIC, MOLDED CASE TYPE: U.L. LISTED FOR SWITCHING DUTY. BREAKERS SHALL HAVE ON OVER- CENTER TRIP FREE, TOGGLE TYPE HANDLE WITH QUICK -MAKE, QUICK -BREAK ACTION. 1. 120/208 VOLT PANELS: SHALL BE GENERAL ELECTRIC TYPE "Q" LINE, BOLT -ON TYPE, WITH MINIMUM SYMMETRICAL INTERRUPTING CAPACITY AS SHOWN. NO SERIES RATING ALLOWED. 2. PROVIDE MULTI -POLE UNITS WITH COMMON TRIP ELEMENT. 3. CIRCUIT BREAKERS USED ON "ON -OFF" CONTROL OF FLUORESCENT LIGHTING (PANELBOARD SWITCHING) SHALL BE UNDERWRITERS - LABORATORIES LISTED AND MARKED "SWD" TO INDICATE THEIR SUITABILITY. E. IDENTIFICATION: PROVIDE SCREWED -ON (NO ADHESIVES) BAKELITE OR PHOTO - ETCHED METALLIC NAMEPLATE IDENTIFICATION AN OUTSIDE OF EACH PANEL SHOWING PANEL DESIGNATION, VOLTAGE, AND PHASE IN MINIMUM 1/4" HIGH LETTERS. EACH PANEL SHALL CONTAIN A METAL- FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. F. COMPLETE SHOP DRAWINGS ARE REQUIRED. SEE ARTICLE 1.08. 2.09 DRY TYPE TRANSFORMER: A. GENERAL: EQUIPMENT SHALL CONFORM TO OR EXCEED REQUIREMENTS OF NEMA, ANSI STANDARD C89.2 FOR DRY TYPE TRANSFORMERS FOR GENERAL APPLICATIONS. ACCEPTABLE PRODUCTS ARE THOSE OF GENERAL ELECTRIC COMPANYS "QHT" LINE OR EQUIVALENT SQUARE D, SIEMENS -ITE, OR CUTTLER - HAMMER. ELECTRICAL RATINGS: 1. PRIMARY WINDINGS VOLTAGE 480 VOLTS, 3- PHASE, DELTA. SECONDARY WINDING VOLTAGES 208Y/120 VOLTS, 3 -PHASE GROUNDED. FREQUENCY: 60 HZ. KVA RATING: AS SHOWN ON DRAWINGS. TOPS: SIX (6) 2.5% FULL CAPACITY TAPS, 2 ABOVE AND 4 BELOW, RATED VOLTAGE. IMPEDANCE: FOR TRANSFORMERS LARGER THAN 75 KVA, 4.5% MINIMUM, 5.75 MAXIMUM 2. WINDING TEMPERATURE RISE SHALL BE 150 DEGREES CENTIGRADE IN ACCORDANCE WITH UL SPECIFICATION ARTICLE 506. 3. TRANSFORMER SHALL BE CAPABLE OF OPERATING AT 100% OF NAMEPLATE RATING CONTINUOUSLY WHILE IN AN AMBIENT TEMPERATURE NOT EXCEEDING 40 DEGREES CENTIGRADE. 4. TRANSFORMER SHALL MEET THE DAILY OVERLOAD REQUIREMENTS OF ANSI STANDARD C57.96. C. VIBRATION ISOLATION, FACTORY- INSTALLED: PROVIDE NEOPRENE RUBBER PADS TO ISOLATE CORE AND COIL ASSEMBLY FROM TRANSFORMER ENCLOSURE. D. INSTALLATION: 1. ANCHOR TRANSFORMER SECURITY WITH MINIMUM 1/2" DIAMETER BOLTS. STRENGTH OF BOLTS USED TO SECURE THE TRANSFORMER SHALL BE SUFFICIENT TO RESIST SHEAR AND UPLIFT PRODUCED BY FORCE EQUAL TO 1/2 OF THE EQUIPMENT MASS APPLIED HORIZONTALLY AT ENTER OF GRAVITY. 2. PROVIDE 1 THICK HIGH RESILIENCY PADS TO ISOLATE TRANSFORMER FROM FLOOR OR PLATFORM. KORFUND "ELASTO RIB" OR EQUIVALENT. 3. USE FLEXIBLE CONDUITS AT LEAST 24" LONG FOR ELECTRICAL CONNECTIONS. 4. PROVIDE GROUNDING OF EACH TRANSFORMER SECONDARY INCLUDING ALL CONDUITS. WIRES, AND CONNECTORS IN ACCORDANCE WITH NEC 250 -26 AND ANY LOCAL ADDITIONAL REGULATIONS. 2.10 INDIVIDUALLY MOUNTED MOTOR CONTROLLER: A, FOR POLYPHASE MOTORS: COMBINATION MOTOR CIRCUIT PROTECTOR AND MAGNETIC STARTER, WITH 3 -LEG OVERLOAD PROTECTION. PROVIDE TWO INTERLOCK CONTACTS OF THE INTERCHANGEABLE OPEN -CLOSE TYPE. PROVIDE HAND -OFF AUTOMATIC SELECTOR SWITCH, MOTOR RUNNING PILOT LIGHT AND RESET BUTTON IN COVER. CIRCUITS 30DV AND OVER SHALL BE PROVIDED WITH INDIVIDUAL 120V CONTROL TRANSFORMERS. B. STARTERS FOR FRACTIONAL HORSEPOWER 120V MOTORS SHALL BE MANUAL TYPE UNLESS SHOWN OTHERWISE, EQUIPPED WITH BUILT -IN OVERLOAD PROTECTION. C. ACCEPTABLE MANUFACTURERS GENERAL ELECTRIC SIEMENS, SQUARE D, CUTTER - HAMMER, AND ALLEN BRADLEY. 2.11 LIGHTING A. LIGHTING TO BE PROVIDED BY OWNER. SUBCONTRACTORS TO INSTALL ALL FIXTURES COMPLETE, INCLUDING LAMPS AND BALLASTS, READY FOR SERVICE. B. SUPPORTS: PROPER SUPPORTS AND MOUNTING ACCESSORIES, SUCH AS HANGERS, STEMS, YOKES, PLASTER FRAMES, ETC SHALL BE PROVIDED AS REQUIRED BY THE TYPE OF CEILING INSTALLED. WHERE SWIVEL CANOPIES OR BALL ALIGNERS ARE SPECIFIED, THEY SHALL CAUSE FIXTURE TO HANG PLUMP REGARDLESS OF CEILING SLOPE. C. FIXTURE DESIGNATION: FIXTURE TYPES ARE DESIGNATED ON DRAWINGS, WHERE ONLY ONE FIXTURE DESIGNATION IS SHOWN, IT APPLIES TO ALL FIXTURES IN THAT ROOM OR AREA. FOR EXACT FIXTURE COUNT AND LOCATION REFER TO REFLECTED CEILING PLAN. D. WIRE 1 -LAMP AND 3-LAMP FLUORESCENT FIXTURES IN TANDEM WHERE REQUIRED BY CODE. E. BALLASTS: ADVANCE, GE, OR APPROVED HIGH FREQUENCY ELECTRONIC, FULL LIGHT OUTPUT, ENERGY SAVING, CLASS "P ", HIGH POWER FACTOR. ETL CERTIFIED, SOUND RATING "A" OR AS INDICATED ON DRAWINGS. 2.12 MISCELLANEOUS MATERIALS: A: SAFETY SWITCHES: HEAVY DUTY TYPE, 600V. HORSEPOWER RATED FOR MOTORS, FUSED OR NON -FUSED AS REQUIRED. MOUNT IN ENCLOSURE WITH NEMA RATING AS REQUIRED FOR THE SPECIFIC APPLICATION GENERAL ELECTRIC, SQUARE D OR CUTLER - HAMMER. PART 3 - EXECUTION 3.01 GENERAL A. ELECTRIC SYSTEM LAYOUTS INDICATED ON THE DRAWINGS ARE GENERALLY DIAGRAMMATIC AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION AND WORK OF OTHER TRADES WILL PERMIT. GOVERN EXACT ROUTING OF CABLE AND WRING AND THE LOCATIONS OF OUTLETS BY THE STRUCTURE AND EQUIPMENT SERVED. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS. B. CONSULT ALL OTHER DRAWINGS, VERIFY SCALES AND REPORT ANY DIMENSIONS, DISCREPANCIES OR OTHER CONFLICTS WITH OWNER BEFORE SUBMITTING BID. C. ALL HOME RUNS TO PANELBOARDS ARE INDICATED AS STARTING FROM THE OUTLET NEAREST THE PANEL AND CONTINUING IN THE GENERAL DIRECTION OF THAT PANEL. CONTINUE SUCH CIRCUITS TO THE PANEL AS THOUGH THE ROUTES WERE COMPLETELY INDICATED. TERMINATE HOMERUNS OF SIGNAL, ALARM, AND COMMUNICATION SYSTEMS IN A SIMILAR MANNER. D. AVOID CUTTING AND BORING HOLES THROUGH STRUCTURE OR STRUCTURAL MEMBERS WHEREVER POSSIBLE. OBTAIN PRIOR APPROVAL OF OWNER AND CONFORM TO ALL STRUCTURAL REQUIREMENTS WHEN CUTTING OR BORING THE STRUCTURE IS NECESSARY AND PERMITTED. E. FURNISH AND INSTALL ALL NECESSARY HARDWARE, HANGERS, BLOCKING, BRACKETS, BRACING, RUNNERS, ETC. REQUIRED FOR EQUIPMENT SPECIFIED UNDER THIS SECTION. F. PROVIDE NECESSARY BACKING REQUIRED TO INSURE RIGID MOUNTING OF OUTLET BOXES. 3.02 WIRING METHODS: A. NO 'ROMEX' OR 'BX' WIRING 15 PERMITTED - ALL ELECTRICAL WIRING MUST BE IN CONDUIT. B. CONDUIT SHALL BE RIGID STEEL, IMC OR EMT AS FOLLOWS: 1. ABOVE GROUND: USE RIGID STEEL IMC OR EMT. A. WET LOCATIONS: RIGID STEEL OR IMC ONLY. B. LOCATIONS SUBJECT TO MECHANICAL INJURY: RIGID STEEL OR IMC ONLY. C. DRY LOCATIONS AND NOT SUBJECT TO MECHANICAL INJURY: EMC OR RIGID STEEL CONDUIT 2. UNDERGROUND: USE RIGID STEEL. C. USE FLEXIBLE CONDUITS IN THE FOLLOWING APPLICATIONS. 1. RECESSED LIGHTING FIXTURES. 2. MOTOR CONNECTIONS. 3. AT BUILDING JOINTS AND WET LOCATIONS, FLEXIBLE CONDUIT SHALL BE LIQUID TIGHT TYPE. D. LIGHT FIXTURES INSTALLED IN SHEETROCK CEILINGS MAY BE WIRED FROM FIXTURE TO FUTURE USING METAL CLAD (MC) CABLE. VERIFY THAT LIGHT FIXTURES ARE PROVIDED WITH JUNCTION BOXES APPROVED FOR THIS PURPOSE. MC TYPE CABLE TO MEET ANSI /NFPA 70 REQUIREMENTS. CABLE ARMOR TO BE INTERLOCKED STEEL METAL TAPE. MC TYPE CABLE MANUFACTURED BY AFC CABLE SYSTEMS, PIRELLI CABLE CORPORATION AND SOUTHWIRE COMPANY ARE APPROVED. MC CABLE SHALL NOT BE USED TO WIRE LIGHT FIXTURES INSTALLED IN LAY -IN OR EXPOSED CEILINGS, OR TO WIRE RECEPTACLES. 3.03 INSTALLATION OF CONDUITS: GENERAL: 1. RUN ALL CONDUIT CONCEALED UNLESS OTHERWISE NOTED OR SHOWN. 2. RUN ALL CONDUIT PARALLEL TO OR AT RIGHT ANGLES TO CENTER LINES OF COLUMNS END BEAMS. 3. CONDUITS ABOVE CEILINGS SHOULD NOT OBSTRUCT REMOVAL OF CEILING TILES, LIGHTING FIXTURES, AIR DIFFUSERS, ETC. 4. CONDUITS SHALL NOT CROSS ANY DUCT SHAFT OR AREA DESIGNATED AS FUTURE DUCT SHAFT HORIZONTALLY. CONDUIT RISERS WHEN ALLOWED IN DUCT SHAFT MUST BE COORDINATED IMTH MECHANICAL WORK TO AVOID ANY CONFLICT. B. CONDUIT SUPPORTS: 1. SUPPORT CONDUITS WITH UNDERWRITER'S LABORATORIES LISTED STEEL CONDUIT SUPPORTS AT INTERVALS REQUIRED BY THE NATIONAL ELECTRIC CODE. WIRES OR SHEET METAL STRIPS ARE NOT ACCEPTABLE FOR CONDUIT SUPPORT. USE CONDUIT HANGERS FOR ALL CONDUITS NOT DIRECTLY FASTENED TO STRUCTURE AND FOR ALL MULTIPLE CONDUIT RUNS. DO NOT ATTACH ANY CONDUIT TO MECHANICAL DUCTS OR PIPES. 2. INDIVIDUAL CONDUITS 1/2" AND 3/4" SIZE FOR LIGHTING MAY BE SUPPORTED FROM CEILING SUPPORT WIRES WITH CADDY CLIPS ONLY IF ACCEPTABLE TO LOCAL CODE. ONLY ONE CONDUIT 15 PERMITTED TO BE ATTACHED TO ANY CEILING SUPPORT WIRE. HANG SUCH CONDUIT 50 AS NOT TO AFFECT LEVEL OF CEILING. 3. AVOID ATTACHING CONDUIT TO FAN PLENUMS. WHEN IT IS NECESSARY TO SUPPORT CONDUIT FROM FAN PLENUM, PROVIDE A LENGTH OF FLEXIBLE CONDUIT BETWEEN PORTION ATTACHED FAN PLENUM AND PORTION ATTACHED TO THE BUILDING TO MINIMIZE TRANSMISSION OF VIBRATION TO THE BUILDING STRUCTURE. C. CONDUIT PENETRATION: 1. PENETRATING FIRE RATED FLOOR OR WALL: INSTALL CONDUIT IN CONDUIT SLEEVE OR FRAMED OPENING. SEAL PENETRATION WITH FIRE RETARDANT SEALANT SPECIFIED HEREIN. 2. PENETRATING ROOF OR EXTERIOR WALL: AVOID PENETRATING ROOF OR EXTERIOR WALL WHERE POSSIBLE. WHERE PENETRATIONS ARE NECESSARY, BUILDING WEATHERPROOF INTEGRITY MUST BE PRESERVED. 3. PENETRATING SOUND INSULATED OR AIR PLENUM WALL: INSTALL CONDUIT IN CONDUIT SLEEVE AND SEAL PENETRATION AS DETAILED ON THE DRAWINGS. 4. PENETRATING NON-FIRE RATED DRY WALL: CONDUIT SLEEVES ARE NOT REQUIRED. PENETRATIONS MUST BE SEALED WITH PLASTER PRIOR TO PAINTING. PENETRATIONS MADE AFTER WALL FINISH 15 APPLIED MUST BE AS SMALL AS POSSIBLE AND PROVIDED WITH ESCUTCHEONS, ONE ON EACH SIDE OF WALL. 5. PENETRATING SUSPENDED CEIUNG: CUT HOLE AS SMALL AS POSSIBLE TO PERMIT CONDUIT PENETRATION. PROVIDE ESCUTCHEON FOR EACH CONDUIT BELOW CEILING. 3.04 CONNECTIONS TO EQUIPMENT: A. GENERAL 1. FURNISH AND INSTALL REQUIRED POWER SUPPLY CONDUIT AND WIRING TO ALL EQUIPMENT. SEE BELOW FOR OTHER WIRING REQUIRED. 2. FURNISH AND INSTALL A DISCONNECT SWITCH IMMEDIATELY AHEAD OF AND ADJACENT TO EACH MAGNETIC MOTOR STARTER OR APPLIANCE UNLESS THE MOTOR APPLIANCE IS LOCATED ADJACENT AND WITHIN SIGHT OF THE SERVING PANELBOARD, CIRCUIT BREAKER OR SWITCH. VERIFY ALL EQUIPMENT NAMEPLATE CURRENT RATINGS PRIOR TO INSTALLATION, 3. INSTALL ALL ROUGH -N WORK FOR EQUIPMENT FROM APPROVED SHOP DRAWINGS TO SUIT THE SPECIFIC REQUIREMENTS OF THE EQUIPMENT. 4. FURNISH AND INSTALL MANUAL THERMAL PROTECTION FOR ALL MOTORS NOT INTEGRALLY EQUIPPED WITH THERMAL PROTECTION. 5. FURNISH 120 VOLT POWER TO EACH CONTROL PANEL AND TIME SWITCH REQUIRING A SOURCE OF POWER TO OPERATE. 3.05 INSULATION OF WIRES: A, PULL NO WIRE INTO ANY PORTION OF THE CONDUIT SYSTEM UNTIL ALL CONSTRUCTION WORK WHICH MIGHT DAMAGE THE WIRE HAS BEEN COMPLETED. B. INSTALL ALL WIRE CONTINUOUS FROM OUTLET TO OUTLET OR TERMINAL TO TERMINAL. SPLICES IN CABLES WHERE REQUIRED SHALL BE MADE IN HANDHOLES, PULL BOXES OR JUNCTION BOXES. MAKE BRANCH CIRCUIT SPLICES IN OUTLET BOXES WITH 8" OF CORRECTLY COLOR -CODED TAILS LEFT IN THE BOX. C. SPLICES IN WIRES AND CABLES SHALL BE MADE UTILIZING MATERIALS AND METHODS DESCRIBED HEREIN BEFORE. D. MAKE ALL GROUND, NEUTRAL AND LINE CONNECTIONS TO RECEPTACLE AND WIRING DEVICE TERMINALS AS RECOMMENDED BY MANUFACTURER. PROVIDE GROUND JUMPER FROM OUTLET BOX TO GROUND TERMINAL OF DEVICES WHEN THE DEVICE 15 NOT APPROVED FOR GROUNDING THROUGH THE MOUNTING SCREWS. E. PROVIDE BRADY WIRE MARKERS WHERE NUMBER OF CONDUCTORS IN A BOX EXCEEDS FOUR. F. MEGGER AND RECORD INSULATION RESISTANCE OF ALL 600 VOLT INSULATED CONDUCTORS SIZE #4/0 AND LARGER USING 500 VOLT MEGGER FOR ONE MINUTE. MAKE TESTS WITH CIRCUITS ISOLATED FROM SOURCE AND LOAD, 3.06 WIRE COLOR CODE: COLOR CODING SHALL BE CONTINUOUS FOR WIRE #12 THROUGH #10 AWG. PHASE CONDUCTORS #8 AND LARGER AND CONDUCTORS OF ANY SIZE IN CABLE ASSEMBLIES MAY HAVE COLORED PHASING TAPE AT TERMINATIONS. COLOR CODE WIRES AS FOLLOWS: VOLTAGE PHASE A PHASE B PHASE C NEUTRAL GROUND 120/208V BLACKRED BLUE WHITE GREEN 277/480V BROWN ORANGE YELLOW GRAY GREEN 3.07 IDENTIFICATION A. PROVIDE NAMEPLATES FAR SWITCHGEARS, PANELBOARD, AND ALL SIMILAR DEVICES. NAMEPLATES SHALL BE SCREWED (NO ADHESIVES) ENGRAVED BAKELITE OR PHOTO- ETCHED METALLIC NAMEPLATE IDENTIFICATION SHOWING PANEL DESIGNATORS, VOLTAGE AND PHASE IN MINIMUM 1/4" HIGH LETTERS. B. PROVIDE DYMO LABELS ON ALL LIGHTING SWITCHES AND CONVENIENCE AND SPECIAL PURPOSE RECEPTACLES TO SHOW PANEL AND CIRCUIT NUMBER TO WHICH THE DEVICE IS CONNECTED. C. EACH BOARD SHALL CONTAIN A METAL - FRAMED CIRCUIT DIRECTORY INSIDE COVER, WITH PLASTIC PROTECTOR. D. PANELBOARD SCHEDULE: AFTER COMPLETION OF WORK, PROVIDE TYPEWRITTEN UPDATED PANELBOARD SCHEDULES FOR ALL PANELBOARD. 3.08 GROUNDING A. ELECTRICAL SERVICE AND SEPARATELY DERIVED ALTERNATING CURRENT SYSTEMS SHALL BE GROUNDED IS ACCORDANCE WITH NEC ARTICLE 250 -3 TO 250 -26, INCLUSIVE. B. GROUND NON- CURRENT CARRYING METAL PORTS OF ELECTRICAL EQUIPMENT ENCLOSURES, FRAMES, CONDUCTOR RACEWAYS OR CABLE TRAYS TO PROVIDE A LOW IMPEDANCE PATH FOR LINE -TO- GROUND FAULT CURRENT AND TO BOND ALL NON-CURRENT CARRYING METAL PARTS TOGETHER. PROVIDE GROUND CONDUCTOR IN EACH RACEWAY SYSTEM IN ADDITION TO CONDUCTORS SHOWN. EQUIPMENT GROUND CONDUCTOR SHALL BE ELECTRICALLY AND MECHANICALLY CONTINUOUS FROM THE ELECTRICAL CIRCUIT SOURCE TO THE EQUIPMENT TO BE GROUNDED. SIZE GROUND CONDUCTORS PER NEC ARTICLE 250 -95 UNLESS LARGER CONDUCTORS ARE SHOWN ON DRAWINGS. C. GROUNDING CONDUCTORS SHALL BE IDENTIFIED WITH GREEN INSULATION. WHERE GREEN INSULATION IS NOT AVAILABLE ON LARGER SIZES, BLOCK INSULATION SHALL BE USED AND SUITABLY IDENTIFIED WITH GREEN TAPE AT EACH JUNCTION BOX OR DEVICE ENCLOSURE. END OF SECTION 1067 Southcenter Mall Tukwila, WA 98188 smith co. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http : / /www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration .r��. No. Date Issues By Check kikg A. 5 210 .., 0 6 -ir 1 03.31.08 PERMIT KLS ItAkktaa �pN1P ��G co��p�7o RECEIVED APR 2 4 2008 PERMIT CENTER Project Name Project Number Description Computer File Scale Template WESTFIELD SOUTHCENTER MALL 02008018.00 ELECTRICAL SPECIFICATIONS CW05- 2008- E3,DWG AS NOTED 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. 11c. E -3