Loading...
HomeMy WebLinkAboutPermit EL08-0470 - KING COUNTY HOUSING AUTHORITYKING COUNTY HOUSING AUTHORITY 600 ANDOVER PK W ELO8-470 CitAbf Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049123 Address: 600 ANDOVER PK W TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -470 Issue Date: 05/09/2008 Permit Expires On: 11/05/2008 Tenant: Name: KING COUNTY HOUSING AUTHORITY Address: 600 ANDOVER PK W , TUKWILA WA Owner: Name: KC HOUSING AUTHORITY Phone: Address: 600 ANDOVER PARK W , TUKWILA WA Contact Person: Name: ROBERT DAVENPORT Phone: 360 668 -9540 Address: 16510 SR 9, STE 3, #223 , SNOHOMISH WA Contractor: Name: FARMERS ELECTRIC Address: 30 E HEMLOCK , OTHELLO WA Contractor License No: FARMEE*42509 Phone: 509 -488 -2822 Expiration Date: 07/31/2008 DESCRIPTION OF WORK: PLACING EXISTING 200 AMP ON EMERGENCY GENERATOR CIRCUIT Value of Electrical: $24,500.00 Fees Collected: $492.00 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and 440 Date: 65191 01) ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or ce of wOr . I am autho ' - d to sign and obtain this electrical permit. Signature: Print Name: A46iGJ - J/fa%////°d^t.1/ Date: S /ef/(1)" This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -470 Printed: 05 -09 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 2623049123 Address: Suite No: Tenant: 600 ANDOVER PK W TUKW KING COUNTY HOUSING AUTHORITY Permit Number: Status: Applied Date: Issue Date: EL08 -470 ISSUED 04/25/2008 05/09/2008 1: ** *ELECTRICAL * ** 2: A copy of the electncal work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: G 4,47-- 4/,/)o/t7; Date: / /d doc: Cond -Elec EL08 -470 Printed: 05-09 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. Project No. i LI (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** King Co Assessor's Tax No.: • 4egi ael 40444./ Site Address: , '/avre� A.f-oce, Suite Number: Floor: Tenant Name: 4 1(0-447 fr New Tenant: ❑ Yes ❑ .. No Property Owners Name: Mailing Address: 6;a0 Gvec4 City 4'ij /Yr- ZS , State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: /7.--z/tel./Jos tgleoA riuo(d•f) Day Telephone: 36ci- 66'x_ 9s z/ 7 Mailing Address: /X57& Ji[ �j Sf $ er7 E .2Z sjvv/ir "Ai /fig J4- 4'S 29,6 City E -Mail Address: /6/2-6-/ (% y.,,.e s e eck • •+ice State Zip Fax Number: a /o- 610-&- - 'Kea/ ELECTRICAL CONTRACTOR INFORMATION` Company Name: --/ Aleo /ate. Mailing Address: /bid ' Se ■ Contact Person: A.44-1 Aiep" ' . -/ E -Mail Address: /a 443-1' .r' e4" e € %•z - •*Kf Contractor Registration Number: /e4/'i (ee- 49-5-0/ ‹oef ayet#+ slur City Day Telephone: Fax Number: Expiration Date: (v/4 -r 244 State Zip Ga -6G - is-ga V6 s- 6l'� - 4f96/ / 2/1f I/u s8 Valuation of Project (contractor's bid price): $ "2-6 ;eV- - ( 49;.0c //ft%2 Scope of Work (please provide detailed information): Will service be altered? Type of Use: Type of work: ❑ New ❑ Addition ❑ Low Voltage ■enerator Property Served by: LI-1---)t-iget Sound Energy ❑ Seattle City Light ❑ Yes PL/516<i✓4 i€P75l /X1 A in more than 50 amps? Oce0.4 dry ,F411.,er."7.1. -7' Yes a [I No ❑ Service Change emodel ❑ Tenant Improvement ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service H:Wpplications\Porms- Applications On Line\4 -2007 - Electrical Permit Application.doc bh Page 1 oft RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O1j#ELECTRICAL CONTRACTOR: Signature: Print Name: Day Telephone: Date: 47/4,7 2cu� t6a- 4. sr p- -7 Mailing Address: /65*-Y0 .a445C /-54ri £. ,041-7-5— f 5lN1,,f w rog, eime- City State Zip IDate Application Accepted: l- Date Application Expires: H:\Applications \Forms - Applications On Line \4-2007 - Electrical Permit Application.doc bh Staff Initials: �5 Page 2 of 2 21/120D City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206-431 -3665 Web site: http:/lwww.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R08 -01339 Initials: JEM User ID: 1165 Payee: FARMER'S ELECTRIC, INC. Payment Date: 04/25/2008 Total Payment: 685.88 SET ID: S000001012 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount anELQ'8 -47 492.00 M08 -118 193.88 TOTAL: 685.88 TRANSACTION LIST: Type Method Description Amount Payment Check 51022 685.88 TOTAL: 685.88 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 492.00 000.322.102.00.0 155.10 000/345.830 38.78 TOTAL: 685.88 1642 04/25 9711 TOTAL 685.88 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 (or- y-io Project ,,''-- ,,II Type of inspection: 100 Address. (goo i Dai/e Date Called: --, Special Instructions: Date Wanted: WI( r m.• Ca: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ag. 4f4Ai 4114 ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IR 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 64-(Po Project: K C • &SIhik Type of Inspection: 2r00 Address: l oev Pic• ul - Date Called: --, Specia II nstructions: Date Wanted: iivi I :m: Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: OK, 4clihe-t L4$E(. aJ got&. Stut i€ 140 141)rcApn44 SE(o /J f6ltJOK 1-CE Inspector: 664461( (Date: 01 is 9 %� El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: ,,,,rn,.046440"°ittaat INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit PERMIT NO. Project: K,I Cro l t-/o u t Je Type of Inspection: 7vo j "7003 Address: 400 A,/00 QK • a. Date Called: Special Instructions: Date Wanted: 51/57 m. Requester: j Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: _ thibouktooNl.c2 Koost4 Inspector: f % / Date: Os/15_ , of $58.00 REINSPECT1ON FEE REQUIRED. Prior o inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: le- Diesel generator set clTM °FE4 �► APR 2 4 2008 QSB7 series engine PERMIT CENTER EPA emissions > Specification sheet 100 kW - 150 kW 60 Hz Our energy working for you.TM Power Generation Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum performance, reliability and versatility for stationary and prime power applications. 1St tti )(II This generator set is designed in facilities certified to IS09001 and manufactured in facilities certified to IS09001 or IS09002. The Prototype Test Support (PTS) program verifies the performance integrity of the generator set design. Cummins Power Generation products bearing the PTS symbol meet the prototype test requirements of NFPA 110 for Level 1 systems. SP• All low voltage models are CSA certified to product class 4215 -01. The generator set is available Listed to UL2200, Stationary Engine Generator Assemblies. Engine certified to U.S. EPA Nonroad Source R CODE COMPLIANCE NFPA 70 - NEC MAY - 2008 Ci BUI s Standards, 40 CFR 89, Tier 3. Features Cummins heavy -duty engine - Rugged 4- cycle, industrial diesel delivers reliable power, low emissions and fast response to load changes. Alternator - Several alternator sizes offer selectable motor starting capability with low reactance 2/3 pitch windings, low waveform distortion with non - linear loads and fault clearing short- circuit capability. Permanent magnet generator (PMG) - Offers enhanced motor starting and fault clearing short- circuit capability. Control system - The PowerCommand® 1.1 electronic control is standard equipment and provides total genset system integration including automatic remote starting /stopping, precise frequency and voltage regulation, alarm and status message display, output metering, auto - shutdown at fault detection and NFPA 110 Level 1 compliance. The optional PowerCommand 2.2 control is UL 508 Listed and provides AmpSentry" protection. Cooling system - Standard integral set - mounted radiator system, designed and tested for rated ambient temperatures, simplifies facility design requirements for rejected heat. E nclosures - Optional weather protective and sound attenuated enclosures are available. N FPA - The genset accepts full rated load in a single step in accordance with NFPA 110 for Level 1 systems. Warranty and service - Backed by a comprehensive warranty and worldwide distributor network. %.7 VI . u.......... 1 ng Prime rating Continuous rating Data sheets DING DI Model kW tkVA1 BO kW IkVA1 60 Hz kW IkVAI 50 Hz kW /kVA1 60 Hz kW /kVAI ti kW IkVA1 60 Hz 50 Hz DSGAA 100 (125) 90 (113) D -3349 DSGAB 125 (156) 113 (141) D -3350 DSGAC 150 (188) 135 (169) D -3351 02007 1 Cummins Power Generation Inc. 1 All rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and "Our energy working for you." are trademarks of Cummins Power Generation. Other company, product or service names may be trademarks or service marks of others. S -15440 (9/07) Generator set specifications Governor regulation class Voltage regulation, no load to full load Random voltage variation Frequency regulation Random frequency variation ± 1% ± 0.5% Isochronous ± 0.25% Radio frequency emissions compliance Engine specifications Design _ 4 cycle, turbocharged and charge air aftercooled Bore 107 mm (4.21 in) Stroke 124.0 mm (4.88 in) Displacement 6.69 litres (408 in') Cylinder block Cast iron, in -line, 6 cylinder Battery capacity 1100 amps minimum at ambient temperature of =18 °C to 0 °C (0 °F to 32 °F) Battery charging alternator 100 amps Starting voltage 12 volt, negative ground Fuel system Direct injection: number 2 diesel fuel Fuel filter Single element, 10 micron filtration, spin -on fuel filter with water separator Air cleaner type Dry replaceable element Lube oil filter type(s) One spin -on, full flow filter Standard cooling system High ambient radiator Alternator specifications Design Brushless, 4 pole, revolving field Stator 2/3 pitch Rotor Single bearing, flexible disc Insulation system Class H Standard temperature rise 150 °C standby @ 40 °C ambient Exciter type Torque match (shunt) standard, PMG optional Phase rotation A (U), B (V), C (W) Altemator cooling Direct drive centrifugal blower fan AC waveform total harmonic distortion < 5% no load to full linear load, < 3% for any single harmonic Telephone influence factor (T1F) < 50 per NEMA MG1 -22.43 Telephone harmonic factor (THF) < 3 Available voltages 60 Hz Three phase Tine- neutral /line -line 50 Hz Single phase line- neutral/line -line • 110/190 • 110/220 • 115/200 • 115/230 Delta • 120/208 • 120/240 Delta • 127/220 • 139/240 • 220/380 • 230/400 • 240/416 • 255/440 • 277/480 • 347/600 • 110/220 • 115/230 • 120/240 • Note: Consult factory for other voltages. Generator set options and accessories Engine ❑ 120 V, 150 W tube oil heater ❑ 120/240 V. 1500 W coolant heater Fuel System ❑ 24 hour dual wall sub -base tank Alternator ❑ 105 °C rise alternator ❑ 125 °C rise alternator ❑ 120 V, 100 W anti - condensation heater ❑ PMG excitation ❑ Single phase Exhaust system ❑ Heavy duty exhaust elbow ❑ Slip on exhaust connection Generator set ❑ Battery ❑ Battery charger ❑ Enclosure: aluminum, steel, weather protective or sound attenuated ❑ Main line circuit breaker • Note: Some options may not be available on all models - consult factory for availability. Our energy working for you."' www.cumminapowcr.cQm ©2007 1 Cummins Power Generation Inc. 1 Al rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and Our energy working for you.° are trademarks of Cummins Power Generation. Other company, product or service names may be trademarks or service marks of others. S -1544e (9/07) ❑ PowerCommand Network Communications Module (NCM) ❑ Remote annunciator panel ❑ Spring isolators ❑ UL 2200 Listed ❑ 2 year prime power warranty ❑ 2 year standby power warranty ❑ 5 year basic power warranty Power Generation A Control system Operator panel features PowerCommand control - An integrated generator set control system providing voltage regulation, engine protection, generator protection, operator interface and isochronous goveming (optional). Control - Provides battery monitoring and testing features and smart- starting control system. InPower" - PC -based service tool available for detailed diagnostics. PCCNet RS485 - Network interface (standard) to devices such as remote annunciator for NFPA 110 applications. Control boards - Potted for environmental protection. Ifligh ambient operation - Suitable for operation in ambient temperatures from -40 °C to +70 °C and altitudes to 13,000 feet (5000 meters). Prototype tested - UL, CSA and CE compliant. AC protection • Over current warning and shutdown • Over and under voltage shutdown • Over and under frequency shutdown • Over excitation (loss of sensing) fault • Field overload Engine protection • Overspeed shutdown • Low oil pressure warning and shutdown • High coolant temperature warning and shutdown • Low coolant level warning or shutdown • Low coolant temperature warning • High, low and weak battery voltage warning • Fail to start (overcrank) shutdown • Fail to crank shutdown • Redundant start disconnect • Cranking lockout • Sensor failure indication • Low fuel level warning or shutdown • Fuel -in- rupture -basin warning or shutdown Operator /display panel • Manual off switch • Alpha- numeric display with pushbutton access for viewing engine and alternator data and providing setup, controls and adjustments (English or international symbols) • LED lamps indicating genset running, not in auto, common warning, common shutdown, manual run mode and remote start • Suitable for operation in ambient temperatures from -20 °C to +70 °C Alternator data • Line -to- neutral AC volts • Line -to -line AC volts • 3 -phase AC current • Frequency • Total kVA Standard control functions Engine data • DC voltage • Lube oil pressure • Coolant temperature Other data • Genset model data • Start attempts, starts, running hours O Fault history • RS485 Modbus interface • Data logging and fault simulation (requires InPower service tool) Digital governing (optional) • Integrated digital electronic isochronous governor • Temperature dynamic governing Digital voltage regulation • Integrated digital electronic voltage regulator 0 2 -phase line -to -line sensing • Configurable torque matching Control functions e Time delay start and cooldown • Glow plug control (some models) • Cycle cranking • PCCNet interface O (2) Configurable inputs • (2) Configurable outputs • Remote emergency stop Options o Auxiliary output relays (2) ❑ 120/240 V, 100 W anti- condensation heater ❑ Remote annunciator with (3) configurable inputs and (4) configurable outputs ❑ PMG alternator excitation O PowerCommand for Windows remote monitoring software (direct connect) ❑ Auxiliary, configurable signal inputs (8) and configurable relay outputs (8) ❑ AC output analogue meters ❑ PowerCommand 2.2 control with AmpSentry protection Standard PowerCommand 1.1 control operator /display panel Our energy working for YOU.TM www.cumminspower.com 02007 1 Cummins Power Generation Inc. 1 All rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc: PowerCommand, InPower and "Our energy working for you." are trademarks of Cummins Power Generation. Other company, product or service names may be trademarks or service marks of others. S -1544e (9/07) Optional AC output analog meters Power Generation Ratings definitions Emergency standby power (ESP): Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. Emergency Standby Power (ESP) is in accordance with ISO 8528. Fuel Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Limited -time running power (LTP): Applicable for supplying power to a constant electrical load for limited hours. Limited Time Running Power (LTP) is in accordance with ISO 8528. Prime power (PRP): Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten percent overload capability is available in accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. Base load (continuous) power (COP): Applicable for supplying power continuously to a constant electrical load for unlimited hours. Continuous Power (COP) in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 and BS 5514. Model DSGAA DSGAB DSGAC Dim "A" mm l$n.) Dim "B" mm (in.) _ — — This outline drawing is for reference only. See respective model data sheet for specific model outline drawing number. Do not use for installation design Dim "C" mm (In.) Set Weight* dry kg (Ibs) Set Weight* wet kg (Ibs) 1180 (2602) 1225 (2700) 1263 (2784) 2656 (104.6) 1100 (43.3) 1549 (61) 2656 (104.6) 1100 (43.3) 1549 (61) 2656 (104.6) 1100 (43.3) 1549 (61) Note: Weights represent a set with standard features. See outline drawings for weights of other configurations. Cummins Power Generation 1400 73'd Avenue N.E. Minneapolis, MN 55432 USA Telephone: 763 574 5000 Fax: 763 574 5298 Important: Back feed to a utility system can cause electrocution and /or property damage. Do not connect to any building's electrical system except through an approved device or after building main switch is open. Our energy working for you: m www.cumminspower.com ©2007 1 Cummins Power Generation Inc. 1 All rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. PowerCommand, InPower and "Our energy working for you." are trademarks of Cummins Power Generation. Other company, product or service names may be trademarks or service marks of others. S -1544e (9/07) Power Generation 0500 -4897 was exported on Dec 10 2007 and is an Un- Controlled Document 6 1 6 ♦ 1 2 7 ID _ C B _ A 700,1 All C CANER G[N(vA TOR Fl[L TRICAL Q701.11= rodl'.7DanraTcFfil{.:IPn- 116p 7I.JOH..7<7 61m61Jt7E1,r x f- B _ A RADIATOR FILL 155.51 OIL TILL (DOM 17 IIAD CONADED STUDS YID TREADED STUDS 11;317;.flnn171111 i�eml7J•R�(I1P.IIF1 '11111mp,IIMIEMCIFE8 g C7 1, �� �.! ..... 1 ■ Ill11 I' „!!!!le MM- m=m[RRRR� Rl�M = -M1��1 ∎111 . •',�� '��- l� �+ � '1E �1'/'f�lll '*r=• MOTES, I. DI FUSIONS 1X011 IN I I ARE 1NCNES. .)1 0. 615. 11.01 NOL[5 NARKED BT 1 AVE 1011 SUBBASE FU L TAMR ATTACHMENT OR SECURI 6 AN MOUh11N6 SURF C(, OH SUPPLEMENTAL VIBRATION ISOLATORS. 3. G[ SET SUPPLIED YITR FLEXIBLE FUEL LIMES INAE CAN B[ C NN[C1E0 10 Eh6l hC INTERFACE POINSS. 177.3 121.61 i11 /, �`�!���� yOSI .... ... � ' _ �_ ... (O_ '-I�1,-. Ii: lI _ 111 11E1 1100 r O: CRANR �.�.1 -- � 4 i_`- I!'6,i;;lii � jr -II - .,I --- y �( -- ` �Tn �J IIF+__ATOM II 17.1 121,71 J 111,E IS.Al 3.1 fU L RE 7pRN lIN[: I067 E 421 LOBE AIM 1/4 .16 XPTF DI SEAL YALE. 3.0 FU L SOPPLP LIIEI HIS 1321 10(06 '11TH Ill-IS MPTF DI15[AL MALI. 1►.n .�j � 1 ® �1 1 _y •�• O ... FUEL RE IUR BARE FI11IM6 FOR 3/B• NOSE SEE NOTE 3,1 TO .5 1. RE ER TO CIRCUIT BREAKER OUTLINE DROVING FOR (1 17 El ETHICAL SILO-OP AREA FOR SPECIFIC BREAKERS. 502,5 180 1.1 RE ER 70 SUBBASE FUEL TEAK OUTLAY' DRA61A6 FOR 111.51 17.11 ELECIRICIL STUB -UP AREA AAAILABLE 01(11 FUEL TEAKS. LECTR CAL 5. TAOULATED MEIGHI AND CS IS FOR 6EMSE1 MIEN NO UEL SUPPLY STUBS OPTIONS. BARR FITTING SEE TOTE 1 1 /.7 ROSE S. SLR MOTE OPTIONAL DUCT ADAPTER 031,1 13281 FUEL FILTER 100,6 155,51 HEARS( CORRECTOR 3 INCH APT 11191-21 ��r, �I • 2051.1 (50.01 - �- _ - ` I NOi15x00MY1 191` �I'I[I�I111I1I �II11 OIL TILL OIL CNCCR -- ��i l�Ill �_ \ /�i _ __ '�- 3.3 CON TACTLLLOSURF EA APPROOOIIYA IEMT RICUALLd15 OF USABLE FEEL REMAIN IM THE TANK. - I .. I, .. L Ill �� IAA ,4I,Qet,� _ - , . •O 00 h 7. ELECTRICAL II RUPTURE BASIN SNITCH PROVIDES A1111 ELECTRICAL CONI ACT CLOSURE /HEN APPRO1 1 AIELI 0 - = c 1 t 1� -1 y IA GALLONS OE FLUID ARE PRESENT IA THE RUPTURE BA51A, IOf 71 IRCUI/ NE1RE110PTIOMALI (SEE SHEARER OVTL IRE FOR CONNECT IOhfl i _i',C`'�, 'j4. ; 1_'' �. `; .`,- 1 -.i1 r. _ \- ` 'KAY �-� -I - L�I� ur,._I -II = LI.,,�/I I) IIFJ�O�I,-J�I ' e e TABULATION 118.71 '. 9-. Nib, )_I ALT DIM 'A• DIY 'B' GEN SET 0E1 AEIUHT FUEL TAME DRY ME16HT AI 11 � JAI, II� r� ` DATA SDATA 1 `r..�^7 , +� R �1= -� � e J 106 1235110.611 +/1 (38.131 1715 (31111 IOee. 111.91 , -._ e 111 130821 117_7_---"=-7 HRH _ 101 1(55 (19.107 (30.531 1761 � _ _ _ Q - - -• tee 101 1271 (50.111 1214 (50,951 175 (38.521 162 136,671 1806 (31501 1011 (20611 DIM B 1L�AS:tf1•�- - • 210 1317 (Shell REF 176.011 IRIS (4116) 1211.1 f 5.11 , I I11 1 I 211 1339 152.711 112 131.011 1912 112801 t1 ;1t L3 u/l (53,001 1000 f.351 2031 111e II 14 3,5 3, I RI UEL FILTER C259 DUAL WALL &E MT RA TANK (2a HOUR) I 25 111 COI ANT - ---- -6 SLOT �- -- 805.9 - .IC DRAIN 1211.6 E (14.5 116,31 ORAIN 1 I I I ° I. Er., A. 1...., . a,l.. 1150 141.31 131,71 150.11 M& 0 f -MICE Fm Fa- PEE �� � �n11 DIY A ,i m ii /Ml GENSEi OUTLINE Ref ft 0590 _ 4897 I':'I11 550,1 (7''71 1517.2 REAR FACE OF BLOCK LIFIIA6 SLOT ' , I. I ...... �u �:n w ti,iA ,, ,,, RE 1.0/ 1 i i - 1B_wXh4c 00 151.71 �,l� 01 -o�I -1II nR'R35.iL..IM56r. A1, E( 2056 (43.01 1111,11 AA la, R i..1 HALF,„ I/6 , 6 I 6 I 4 'T 3 I 2 I 1 LPr *TM 1 UTERI 0500 -4897 was exported on: Dec 10 2007 and is an Un- Controlled Document 0 1 6 I 4 ,' a L 2 I 0 C 4 B A MALI moor A I PRpRTIG9.P[L[AO[ 3 II 111 417, If 0 0 4— 0 A I - 11 4 11 00 34 sr T104A[ O [Al 1292 150.041 151 121.001 Si00i L0CAT109 311 *12TH j���j j t 0.90] 28 15 1050 Al 1 111 11 1100 (13 6EMS[T 331 I 20 t 22.10 11 .31 II 111.01 4001111116 HOLE l0CAT109S 1T/ 11.11 [T.II L[CT3ICAL Me 9P L0CAT109 2050 6[9011 l[9619 1112,11] MOUNTING PAD LAYOUT C259 DUAL WALL SUBSET FUEL TANK (24 HOUR) I I TT— .% nr,sa. m .....-1-1-......0 ..• - . 1.1811 .. g P� H m.<A.�1 i8 _ , L HUSET OUTLINE ,I..,. z iA S.n iii �1 it Y.n..w 111 .- e_H[MMIk ` ..00-01 -01 n..Q cm P. .... .eIx. ■ 20 y '7:''u[G,,k POT — p 0500.1897 I . . 6 1 0 I 4 T 3 I 2 ' 1 i01 ✓[A0 1 C E 01 0500 -4897 was exported on: Dec 10 2007 and is an Un- Controlled Document 0 1 6 1 4 4' 0 1 Z I 0 - 0 6 A FUEL GAGE •'11044 100 10EL 20001 50LTCR (0415 00 *5151 FUEL FILL 2 IACR APT FEMALE 1-111 INCU EIPI FEMALE Lf00 YOIC fl (° 111111111 " T A" r 0 - 0 6 - A .,. .,- I 1 n 1194.4/ 2 INCH APT FEMALE 21 502.5 115.61 21 100 III 1100 11]1 EMERGENCY 16117 1 IXCN API FEMALE 110101AL MIT - ;�� 1 11.1 i /.11 0 _. • L; J I:41 [1 :T.:)‘-i jU 21 111 141 OVER PAAEL A01 510011 IA1fRAAl (PIL 59014 TO 1A4A 2 IACR MP1 Ff C • 7101AL 1445 DYE1FL00 OR -ill IACR API FEMALE 4E4111 2 Wit APT FEMALE (_ =— j //. .110441 400441 Y AT ENG140 RE 7UR PT IDAAI FUEL 114.117 2 140 401 FEMALE EA61AF SUPPLY 516 1401 401 FEMALE _ YER6ENC1 MEAT 1 INCx NP1 FYA1[ / I i 122.4 SEE ADTE 1 124.11 � 1 1 2054 1112.141 ��-Illica=. o 21 105 II III 21 1 1 511 /�� /�j/ ilEIMiI I' 21 1211.4 21 158.5 --•{ 150.051 121.11 T 1 I 1 I '• 1...1...1.• I ...^•+ 1•" ^• 1E • Lisa PGF Cit•P ®�D•oL�u ° !p.S111E. +9 'mutt , 1 R104/iPAL . 1 Amu ••O.UEAAU4 GENSET OUTLINE ft! 0500.1897 Iq l MIfpl1( VA ,s . ,..I .0 110 z EI , A 6 I 4 Is I Z I I IP..IE16141El 0500 -4897 was exported on Dec 10 2007 and is an Un- Controlled Document ° N 4 4. 2 I 1 A dS1=1.0 MOM! . `. 0 C C- A A 1111.4 1111.41 77I�FR 1Mt11n0Y �\ � i u,„_:,lnnoua*.nnu s-- muru nnmrn MOM . _- Mil 11E01 E Ill '1• 11Y 1' a1u� 1[ 1iIIl • rRl IL11 111E Ll 1 WIID 14 S1E(l l l• 1111 121 i rlgl 441 pf i Gli I 0AO t1 14 ii iii , _ ..1. i Ill 1111 111.11 M1111. Ill 310 IMMI ,1111 14401 • 11111111111111 • I • • • . • • • •. . • • • • . .. . NOTE% I. DINENS IONS SK01N 135 1 I ARE 14003. t. NWSIN4 AAO MUFFLER lit 1610t 1e011 ns101Yt1 NI ISIS 1l1.l1 1111 M.111 !311111111 NI1113,31 1111".1 • 111P41!1c11Mat 1141111111111: •••11111 . . • 14 WI !Wit 11111.121 N13 IL41 1111441 111 1113 111.11 111111.41 (MY 11111 1111 111111 .III • • • • • 511 N1• 14.11 111 135.111 1111 111131 1111 111511 111111111111 • IIm! 311 1111131.11 51(131.41 017 11110 35111 it, i1 411311 105 131.11 NM ❑1.111 114 Non 5111 44511 11012\C / l III 111 111 1111.....) • 1111111111 11111111111111 •111111111111/1•. • • .%. • i\\ s _ v' L`Cna ACCESS 1 DOOR " �� DOOR LATCHES ARE CENTER LIFT XET LOCKABLE AAO SECTION eel DOOR 541354 PADLOCXABL[ 1A 000251 035110% ODOR 111004 IOe1 111 1-1 • . • . ' • . - - - - - - - - - . .. • __1 - :__ IN - MI - . : - - - In - - - - - - - - - In - in 1.1 = - • 2AMA 1X.11 - - - M - - 1I - .I I. • .. d ig.1 111..1. Al . . 1021.5 140.21 DIN If , . r I r °'N" 11.2 "A'S' F232 SOUND HOUSING (STEEL) W /MUFFLER 104 s e11 [n.11 I34.51 - - F233 SOUND HOUSING (ALUMINUM) W /MUFFLER 1100.1 111,31 L_ 11i6u111o1 1 °I..1••� ^••W• T�"d81j I 3m• s 1_35E1 sirs 00 PG �—M it —fyu>� • 4 33.1.3 3:11 113 N1.1', . M rim 5.01. 1 , i -Ilu� - i ABEL 1l I.ltNYIA4 GENSET OUTLINE 0112 01 0500.4897 ]I='1Lr , y �.�. e33s.0147 p� ow%— ,.u.lc W 11: • 1.eI 1=11■ Ire I A 1 4 'T 3 1 2 1 1 1R1.IE1140 0E1 0500 -4897 was exported on: Dec 10 2007 and is an Un- Controlled Document 6 1 6 I 4 4. ] 1 2 I I D _ D 6 A u Y `. •_TEFJ7_ • o _ 0 E 6 I _ " J 116.6 11151 PPM/ I 1 IIR III IIR. 7311! 413113 .i17tI t 1 I SR 50-111 10 -38 II 1 • 1131311101 cif• 3113.1• Al Y' 0331{11 f�pT6L¢f•�L10 I 41.26 i. la 1117131 lb 4�., f[ � 1 r13l 1'71' I 1 y 1 • • • • • • • • • A • % • . •• • • • 11111111•U•1u „I' • •1Ni/11 „,,,,,,I • 11111!T:1111 "11 „IE-_ • 1111111111111• 111♦11111111 • llIIUUIU11U11l %IL1I111111 z 1 a.. •-•, 'I,,, .r1Io31.1 IIO J i i. "' • • • • • • • • t0 131010.11 HI 131.111 31010531 1x1113811 ill 1303 10.11 111131.111 7314 115511 1 U 11 111311 i38 1303 01.51 III 133371 7511 1•01 111311W1 10 10110.11 383131.111 [!011101 7113 110411 111 101 113.11 01 138.111 051 131111 113S 11101 311 1311 111.01 02 131.111 011 11011 3111 113871 1121711 10010.11 1103311f1 11/1111111 30110111 Want ACCESS rI [NITER LIFT SECT• 3000 (OPT !MALI 652 ODOR 5 1116 DOOR IRE 11 000057 OCIASL KEY IPADLOL ISLE 10111106141 1067 �• • • . . • • • • • . Momal ` Cif MEM ___ MINIM i •-- • Iowa --S ‘.`... • • --S moss •m_• • moor or --S woo mom OMB =MIN MUM MEM 2456.3 (56.71 • •_. Mae MISS owe MEM I ail i 7 722.1 121.411 sf 12.11 . 11 DIY 6 = DIYI �F173 SOUND HOUSING (STEEL) W /MUFFLER 626.2 -4-- 111•5 636 11.51 414.11 000,6 [10,!1 F2I7 -2 SOUND HOUSING (ALUMINUM) W /MUFFLER MI 1 •i J PlI I 1 • f � •' P.P.,. I m•• +•�••• '0� T.ABEL ml!Eel PGF �11�MPaa�aOR y.utl1ilt& i _ 11 J t«:l.0la1011 11; vM6■ R 1. i:w a m4wl•r ;�� s T ABEL GENSET OUTLINE cm pI0500.1897 1,-.70 .1.6.11[YY1116 06Y0•16-III y101031,1133 wKu: ..3j13.038 Ill 5 _r_ 6 I 4 T 3 I 2 I I EonIc1Y[EI1 0500 -4897 was exported on Dec 10 2007 and is an Un- Controlled Document B s ♦ d, S A tlWU 1 Up IA C _ 0 F el A. MD Itt E6 OUTLET ' 1661 �{ 1 1 0 5 1 IIOINU rNJJfn I I 1 ;,1401!!01 N N 11 G II II N J I It Man 1 0 1 . { 1 1 . 0 1 0 D. 1 it , 5 1 1 , 1 75.711 I 1 I / \ ` ill! •1 LIT Igo 012 '1' NY - {• G": :1 411 1 tKl lA1;ip1¢I RIMI I fl OAhP MNI 1 Mt IELGt 1 / I! tl 10.71 /A1 • . . NI W. 141.41 0I IM..I m/ Nlul IN. 111111 !,� 86/ 101111.41 111 114.131 MN 11,111 Mt 111101 507 110.71 ` • 141 Gu 161.71 11110.21 NN 11401 1... Ia .I ill 1114 111.11 I7t 114.111 1111 111411 140 111011 411 111111.11 NI 1N. /11 N2 111611 MS 114111 RADIATOR PILL 611\ ��' I • //)\\ • . • . ill II10 113.11 IN 12.411 3161 14011 Mr 111271 N! /N! 1ST 113.11 IMO IS DI MI ISM] 1411 111011 ACCESS COOLA111 RECOVER( 00(1LE ACCESS 0111R0. ACCESS DOOR 111 DOOR $111116 711.0 111.71 WI [11 115.0 11.11 11 DOZ0S1 - -- 1100 (17.71 I e 1°1.11 �� 8•= �� 0: . M!= I 1 • • - •.,.C- • IN.110"1•1t• •-iny,IM •�e,a ..ice. - as a,.,•,• e,111,1MIS• =_,.ar•a- ilt =g= • ....... Ilkiin;•a..•iM a,e S. IOC NI MINI - ■ a MAI N MUNN a - -M M N �� a. EIa =T,�la 1M M Oa • DIY .. .' B • • Imo_ 1 DIM A - - - - -� -- 711.1 115.5] 976 (76.51 f16 F182 WEATHER HOUSING (STEEL) W /MUFFLER 7 6'5' F216 WEATHER HOUSING (ALUMINUM) W /MUFFLER 117°. 1 (68. 41 I- 1 .r.r.... 1 iA7.m l...► 0 ,141, gm • 1.1et1 //7�11 0PC ` II mao161m , Q • 14801 GENSET OUTLINE ..... , « L «.nn1« . h•.'Yr..1 1 14 N h ..B.REI111151 04.01.11 Minsk Nv O. POP CtN 00500 -1697 1h11 r IN.01.,. ..4.)•u. I+e .i+�n1. e 1 17 1 4 is S I 2 1 I IPr•/ER6111EERi Model: DSGAB Frequency: 60 Fuel type: Diesel Emissions level: EPA Nonroad Tier 3 > Generator set data sheet 125 kW standby Our energy working for you.TM Power Generation Exhaust emission data sheet: EDS -1084 EPA Tier 3 exhaust emission compliance sheet: EPA -1118 Sound performance data sheet: MSP -1056 Cooling performance data sheet: MCP -171 Prototype test summary data sheet: PTS -285 Standard set - mounted radiator cooling outline: 500 -4659 Optional set - mounted radiator cooling outline: 1/4 Optional heat exchanger cooling outline: 3/4 Optional remote radiator cooling outline: 1/4 Fuel consumption Standby Prime Continuous kW (kVA) kW (kVA) kW (kVA) Ratings 125 156) 113 (141) Cast iron, in -line, 6 cylinder Load 1/4 1/2 3/4 Full 1/4 1/2 3/4 Full Full US gph 3.38 5.77 7.89 10.00 3.10 5.21 7.32 9.15 1800 L/hr 12.8 21.9 29.9 37.9 11.7 19.7 27.7 34.7 Engine Standby rating I Prime I rating Continuous rating Engine manufacturer Cummins Engine model QSB7 -G3 NR3 Configuration Cast iron, in -line, 6 cylinder 127 Aspiration Turbocharged and CAC Maximum return restriction, mm Hg (in Hg) Gross engine power output, kWm (bhp) 186 (250) 162 (217) BMEP at set rated load, kPa (psi) 1435 (208) 1301 (189) Bore, mm (in) 107 (4.21) Stroke, mm (in) 124 (4.88) Rated speed, rpm 1800 Piston speed, m/s (ft/min) 7.4 (1464) Compression ratio 17.3:1 Lube oil capacity, L (qt) 17.5 (18.5) Overspeed limit, rpm 2100 Regenerative power, kW 20.4 Fuel flow Maximum fuel flow, Vhr (US gph) 106 (28) Maximum fuel flow with C174, Vhr (US gph) Maximum fuel inlet restriction w/ clean filter, mm Hg (in Hg) 127 (5) Maximum return restriction, mm Hg (in Hg) 152 (6) 02007 1 Cummins Power Generation Inc. 1 All rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. Our energy working for you." Is a trademark of Cummins Power Generation. D -3350b (9/07) Air Combustion air, m' /min (scfm) Maximum air cleaner restriction w /clean filter, kPa (n H2O) Alternator cooling air, m3 /min (cfm) Standby rating Prime rating Continuous rating 13.5 1476) 12.7 (449) 31 (15) 37.0 (1308) Exhaust Exhaust gas flow at set rated Toad, m3 /min (cfm) Exhaust gas temperature, ° C (° F) Maximum exhaust back pressure, kPa (in H2O) 32.0 (1129) 29.7 (1050) 466 (871) 454 (850) 10 (40) Standard set - mounted radiator cooling Ambient design, °C ( °F) Ambient design, ° C (° F) 54 (129) Fan load, kWm (HP) Fan load, kWm (HP) 6.5 (8.7) Total heat radiated to room, MJ /min (BTU /min) Coolant capacity (with radiator), L (US Gal) 23 (6:1) Total heat rejection, MJ /min (BTU /min) Cooling system air flow, m3 /min (scfm) 324 (11450) Maximum cooling air flow static restriction, kPa (in. H20) Maximum raw water flow, jacket water circuit, Umin (US GaVmin) Total heat rejection, MJ /min (BTU /min) 7.36 (6973) _ 6.71 (6363) Maximum raw water flow, fuel circuit, Umin (US GaVmin) Maximum cooling air flow static restriction, kPa (in H2O) 0.12 (0.5) Minimum raw water flow © 27 °C (80 °F) Inlet remp, after - cooler circuit, Umin (US GaVmin) Optional set - mounted radiator cooling Ambient design, °C ( °F) Fan load, kWm (HP) Coolant capacity (with radiator), L (US Gal.) Total heat radiated to room, MJ /min (BTU /min) Cooling system air flow, m' /min (scfm) Maximum raw water pressure, jacket water circuit, kPa (psi) Total heat rejection, MJ /min (BTU /min) Maximum raw water pressure, fuel circuit, kPa (psi) Maximum cooling air flow static restriction, kPa (in. H20) Maximum raw water flow, jacket water circuit, Umin (US GaVmin) Optional heat exchanger cooling Set coolant capacity, L (US Gal.) Heat rejected, jacket water circuit, MJ /min (BTU /min) Heat rejected, after - cooler circuit, MJ /min (BTU /min) Heat rejected, fuel circuit, MJ /min (BTU /min) Total heat radiated to room, MJ /min (BTU /min) Maximum raw water pressure, jacket water circuit, kPa (psi) Maximum raw water pressure, sftercooler circuit, kPa (psi) Maximum raw water pressure, fuel circuit, kPa (psi) Maximum raw water flow, jacket water circuit, Umin (US GaVmin) i Maximum raw water flow, aftercooler circuit, Umin (US Gal /min) Maximum raw water flow, fuel circuit, Umin (US GaVmin) Minimum raw water flow @ 27 °C (80 °F) Inlet temp, jacket water circuit, Umin (US GaVmin) Minimum raw water flow © 27 °C (80 °F) Inlet remp, after - cooler circuit, Umin (US GaVmin) Minimum raw water flow © 27 °C (80 °F) Inlet temp, fuel circuit, Umin (US GaVmin) Raw water delta P @ min flow, jacket water circuit, kPa (psi) Raw water delta P @ min flow, after - cooler circuit, kPa (psi) Raw water delta P © min flow, fuel circuit, kPa (psi) Maximum jacket water outlet temp, °C ( °F) Maximum after- cooler inlet temp, °C ( °F) Maximum after - cooler inlet temp @ 25 °C (77 °F) ambient, °C( °F) Our energy working for you: u www.cummin,pQwer.QQm ©2007 1 Cummins Power Generation Inc. 1 All rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. Our energy working for you." is a trademark of Cummins Power Generation. D -3350b (9/07) Power Generation Optional remote radiator cooling' Set coolant capacity, L (US Gal.) Max flow rate O max friction head, jacket water circuit, L/min (US GaVmin) _ Standby rating Prime Cont(nuoaits rating rating Heat rejected, jacket water circuit, MJ /min (BTU /min) Total heat radiated to room, MJ /min (BTU /min) Maximum friction head, jacket water circuit, kPa (psi) Maximum static head, jacket water circuit , m (ft) Maximum jacket water outlet temp, °C ( °F) Weights2 Unit dry weight kgs (lbs.) Unit wet weight kgs (lbs.) 1225 (2700) Notes: 'For non - standard remote installations contact your local Cummins Power Generation representative: :Weights represent a set with standard features. See outline drawing for weights of other configurations. Oerating factors Standby Prime Engine power available up to 3048 m (10,000 ft) at ambient temperature up to 50° C (122° F). Consult your Cummins Power Generation distributor for temperature and ambient requirements above these parameters. Engine power available up to 3048 m (10,000 ft) at ambient temperature up to 40° C (104° F) and 2804 m (9200 ft) at 50° C (122° F): Consult your Cummins Power Generation ciist "ributo "r for temperature and ambient requirements above these parameters. Continuous Ratings definitions Emergency standby power (ESP): Llmited -time running power (LTP): Prime power (PRP): Base Toad (continuous) power (COP): Applicable for supplying power to Applicable for supplying power Applicable for supplying power Applicable for supplying power varying electrical load for the to a constant electrical load for to varying electrical load for continuously to a constant duration of power interruption of a limited hours. Limited Time unlimited hours. Prime Power electrical load for unlimited reliable utility source. Emergency Running Power (LTP) is in (PRP) is in accordance with ISO hours. Continuous Power (COP) Standby Power (ESP) is in accordance with ISO 8528. Fuel accordance with ISO 8528. 8528. Ten percent overload capability is available in is in accordance with ISO 8528, ISO 3046, AS 2789, DIN 6271 Stop power in accordance with ISO 3046, AS 2789, DIN 6271 and accordance with ISO 3046, AS 2789, DIN 6271 and BS 5514. and BS 5514. BS 5514. Our energy working for you: m www.cumminspower.com ©2007 1 Cummins Power Generation Inc. 1 All rights reserved 1 Specifications subject to change without notice 1 Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. Our energy working for you:" is a trademark of Cummins Power Generation. D -3350b (9/07) Power Generation Alternator data Three Phase Table' 105' C 105° C 105° C 105' C 125° C 125' C 125' C 125' C 125' C 150' C 150' C 150' C Feature Code 6418 B415 B268 B304 B417 B414 B267 B246 B303 B416 B413 B419 Alternator Data Sheet 209 209 211 208 208 208 211 208 208 208 208 208 Number Voltage Ranges 110/190 120/208 120/208 347/600 110/190 120/208 120/208 139/240 347/600 110/190 120/208 347/600 Surge kW Thru Thru Thru 156 Thru Thru Thru 277/480 Thru Thru Motor Starting kVA (at Shunt 120/208 139/240 139/240 250 120/208 139/240 139/240 120/208 139/240 90% sustained voltage) 220/380 240/416 240/416 220/380 240/416 240/416 220/380 240/416 PMG Thru Thru Thru 290 Thru Thru Thru Thru Thru 240/416 277/480 277/480 240/416 277/480 277/480 240/416 277/480 Surge kW 160 161 163 160 159 159 163 160 160 159 160 160 Motor Starting kVA (at Shunt 516 516 672 422 422 422 672 422 422 422 422 422 90% sustained voltage) PMG 607 607 791 497 497 497 791 497 497 497 497 497 Full Load Current - Amps at Standby Rating 120/2013 127/220 139/240 220/380 240/416 254/440 277/480 347/600 434 411 376 238 217 205 188 151 Single Phase Table 105' C 105' C 105' C 125' C 125' C 125' C 150' C Feature Code B418 6415 B268 B417 6414 B267 B413 Alternator Data Sheet 209 209 211 208 208 211 208 Number Voltage Ranges 120/240' 120/240' 120/240' 120/240' 120/240' 120/240' 120/240' Surge kW 156 156 159 156 156 159 156 Motor Starting kVA (at Shunt 305 305 395 250 250 395 250 90% sustained voltage) PMG 360 360 465 290 290 465 290 Full Load Current - Amps at Standby Rating 120/240' 120/24Q' 347 521 ' Single phase power can be taken from a three phase generator set at up to 2/3 set rated 3 -phase kW at 1.0 power factor. Also see Note 3 below. ' The broad range alternators can supply single phase output up to 2/3 set rated 3 -phase kW at 1.0 power factor. ' The extended stack (full single phase output) and 4 lead alternators can supply single phase output up to full set rated 3 -phase kW at 1.0 power factor. Formulas for calculating full Toad currents: Three phase output Single phase output kW x 1000 Voltage x 1.73 x 0.8 kW x Single Phase Factor x 1000 Voltage Cummins Power Generation 1400 73" Avenue N.E. Minneapolis, MN 55432 USA Telephone: 763 574 5000 Fax: 763 574 5298 Important: Back feed to a utility system can cause electrocution and/or property damage. Do not connect to any building's electrical system except through an approved device or after building main switch is open. Our energy working for YOU.TM www.cumminspower,00m 02007 l Cummins Power Generation Inc. l All rights reserved l Specifications subject to change without notice l Cummins Power Generation and Cummins are registered trademarks of Cummins Inc. "Our energy working for you." is a trademark of Cummins Power Generation. D -3350b (9/07) Power Generation ',PERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -470 DATE: 04 -25 -08 PROJECT NAME: KING COUNTY HOUSING AUTHORITY SITE ADDRESS: 600 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: B iltlin 'vision Public Works ❑ -Db Fire Prevention Structural Planning Division Permit Coordinator 11 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -29 -08 Not Applicable Li Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-27-08 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Look Up a Contractor, Elect an or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License FARMEE *42509 Licensee Name FARMERS ELECTRIC Licensee Type ELECTRICAL CONTRACTOR UBI 600107216 Ind. Ins. Account Id Business Type CORPORATION Address 1 30 E HEMLOCK Address 2 City OTHELLO County ADAMS State WA Zip 99344 Phone 5094882822 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 9/29/1958 Expiration Date 7/31/2008 Suspend Date Separation Date Parent Company Previous License Next License Associated License BOOTHF *093LA Electrical Administrator Information License BOOTHF *093LA Name BOOTH, FRANK Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date BOOTH, FRANK 01/01/1980 BOOTH, BRENDA 01/01/1980 BOOTH, JOSH 01/01/1980 BOOTH, FRANK AGENT 01/01/1980 • Page 1 of 2 https: // fortress. wa. gov /lni/bbip /printer.aspx ?License= FARMEE *42509 05/09/2008 m 011 411 u IL.rr•( r EA McNtl 50' -a" Gorr 1c) • . I so' —o LEGAL DESCRIPTION 170' -© 1-0wmg mcor z plh'f icl`I (o' -od �S..815 /2 3Z" 0, 0670,00j ?40- i--iAN p G4 vilzEP c,F21121411-140. l� 4 SI k7Bvv,441,.I4. -twit7vaXI�T'1. au �—K. vie NW ! -1 1 W -r I ,-rcH • eX IST`,- 15>wil4 cow.. hone EXi -t hlf��tV pRs=tvi P . NEW u � 0 :GONG: W44r,14 . That portion of the northeast quarter of the southeast quarter of Section 26, Ibwnsh.ip 23 North,, Range 4 East, W.M., in King County, Washington, described as follows: Cormencing •at the southwest corner, of the said northeast quarter of the southoeast quarter; thence South 88 12'32" East 30.00 feet to the Point of Origin of the center- line of the P -17 drainage channel, which channel continues South 88`' 12'32"' East to terminus at the westerly margin of Christensen Road; thence continuing South 88c' 12'32" Est 360.00 feet; thence North 01 47'28" East 69.00 feet to the northerly margin of Minkler Bo8levard; thence continuing North O1 .47' 28" East 319.85 feet ter the TALE POINT OF BEGINNING of the parcel to be described herein; thence from said TRUE POINT OF BEGINNING North 88 12'32" West 360.00 feet to the easterly 'margin of Andover f �a rk West as recorded under Auditor's File No. 6355529, "Volume 5095, pager 63 and 64, Records of King.Country., Washington; thence alone said .easterly margin North 01 °47'28" East 150.00 feet; thence'leavng said easterly margin South 88. 12'32" East 6Q.00 feet; thence South 'O1.47' 28 "West 150.00 feet to the TRUE POINT OF BEGINNING. E z. 0 O T SUR I.�.�r tai �1. clINO . 8 /2./ 2'" E : ;34,0,901 FILE OPY Permit No. _ lar review approval is subject to errors and ornissic. • • royal of construction documents does not authoeze e violation of any adopted code or ordinance. RecRipt approve: Feld Copy and conditions is acknoWlet ed: I By `% " F�EMEN 1u/ rr .m pw, ur parr mm1 4 11-' r�4 t°411 $'p1 .u. • • Ole, ` , ? . ; r! ,f..1 rtI I 11 5 REVISIONS No char3. -s shall be mad* to fh of 4yo k without prior approval ofopQ Tu ila Building Division. • ReVlS ti . C tna s and ay include additional plan review fees. .�a� �.cra+.y1 ao. I t RTM.. 6twrwe..•s. J2Jwr lull CURB _:TYPE VED WAU(W. AY -‘1466 Ld NEM MAN'; t -3 •u WHITE: UrTERNATiONAi.: SYM$OLi OF., ACCESS TO BE ..� ! PANTED N PAVEMENT , • CURB TYPE S*.oPE VANES 1/4'.� : r4.. Ipp Ill • C.LJ TYPE ZNI�}G) C-M FIRE ZONE . 5 QGGUP ANDY - 2 CON5Tt2ltCTION -ry'PE - N SITE AREA 54 726 S, F. C t. 24 ACRE 91 Te CoYERAO - /S.7 , PAR KiMc ReQUIRat) 4/000 5. : NAT = 65 CA.C.C.) @3.1//0040 5,P. 4RoES = 61 CTw ;wILAD PAMKIN PIWVIDeP 50 STAc.t.S MAX- SLOPE 1:50 112' R �c.00R AkEA COWER - '14.7Lf Q.F. UPP5iR - to,4(2 5,r, TOT - (;a; 4a 5,f [11 U W 2 U CC Q W 1 CCZ Q I `L 0 U CC 0 Z W 0 12•-6 ,,, „A RECEIVED CITY OF TUKWILA APR 2 4 2008 PERMIT CENTER D U M P S T E R S C R E E N CURB PROFILES A2.1 04YMYtc SLUE PRINT CO moo c,r md• ‘-7ir/k U/7)! tr) /02 cEe Tell) Incoming 200A Service - -Fused (q7 200 A (per PSE) pt: ( ) Iry CQQ- 7H1/z/ ($2 #e--Or C'' C f- a -1 ,c-*77 7 1 /9° MIN ■EMM/ Imaimum iminimumm summimmul iiiMiiMEii s R& ?&? (rot Tfl/C(ctir rd 1tm9 F') Load Calculations for New Generator 1Gxt5T /.vii yZ Westinghouse 225A 480V, 3 phase, 4 wire, 42 space w/ Qty Amps Description 9 20A/1P lighting loads 1 30Af2P hot water Toad 2 20A/1P duct heaters 1 40A/3P HVAC load 200A/3P 75 KVA transformer VA load/ea Sub T1 VA demand f. 4432 39888 1.25 4500 4500 1.00 4432 8864 1.00 24930 24930 1.00 75000 75000 1.00 Total VA 49860 4500 8864 24930 75000 Panel PC fed from 75 KVA transformer 14 20A/1P receptacle loads 3 30NIP UPS loads 2 20A/1P Genset loads—(cc heater, etc) 225A in Generator >> 163154 Total VA 1920 2880 1920 26880 8640 3840 1.00 1.00 1.00 26880 8640 3840 part of 75 KVA load above 39360 Total VA ELOBA-tio RECEIVED CITY OF TUKWiLA APR 2 4 NIA PERMIT CENTER FARMERS ELECTRIC, Inc. 16510 SR9 SE, SUITE E, # 225 SNOHOMISH, WA 98296 for all your electrical needs DESIGNED BY: RRD DRAWN BY: RRD PROJECT NUMBER: 04---08 4- DATE: 03/11/08 J J 1 REVISIONS NO DATE DESCRIPTION 1. 03/21/2008 Review 2. 3/24/2008 Plan Updates 1 Authority 600 Andover Park West, Tukwila, WA 98188 -2583 Generator Pad Notes E -1