Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0471 - ASEMCO
ASEMCO 500 ANDOVER PK E ELO8-471 Cityyif Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049097 Address: S00 ANDOVER PK E TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -471 Issue Date: 06/12/2008 Permit Expires On: 12/09/2008 Tenant: Name: ASEMCO Address: 500 ANDOVER PK E , TUKWILA WA Owner: Name: VALENTINE/WALKER PROPERTIES LLC Phone: Address: 480 ANDOVER PARK E , SEATTLE WA Contact Person: Name: KEVIN LEWIS Phone: 253 - 813 -5817 Address: 804 W MEEKER ST , KENT WA Contractor: Name: A C ELECTRIC SERVICE INC Phone: 253 852 -0225 Address: 804 W MEEKER ST STE 102 , KENT WA Contractor License No: ACELESI025DF Expiration Date: 03/06/2010 DESCRIPTION OF WORK: INSTALL (16) EQUIPMENT CIRCUITS, (37) CORD DROPS, (1) AHU CIRCUIT. ALL FROM EXISTING 2000 AMP SERVICE Value of Electrical: $40,000.00 Fees Collected: $922.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: JO:( W^' Date: L 1'-- -0 l/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the pgrfornce • ork. I am authorized to sign and obtain this electrical permit. Signature: Print Name: 6 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 6 (2--a(s) doc: EL -4/07 EL08 -471 Printed: 06-12 -2008 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049097 Address: 500 ANDOVER PK E TUKW Suite No: Tenant: ASEMCO PERMIT CONDITIONS Permit Number: EL08 -471 Status: ISSUED Applied Date: 04/25/2008 Issue Date: 06/12/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or e performance of work. / cl Signature: � u �./[ JU Date: t< • t z ' tJ Print Name:�� doc: Cond -Elec EL08 -471 Printed: 06-12 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http: //www. ci. tukwila. wa. us Electrical Permit No. E.-L-0 $ - j,1 Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION dia6OM —1 Oq 1 King Co Assessor's Tax No.: ' Site Address: !inn Pkocicio mi. A2 t L V Suite Number: Floor: Tenant Name: As E ML C. New Tenant: ❑ Yes ❑ ..No Property Owners Name: L i,...Ro d Lo Rd' V A I E0+ I t-e 1 Lk.),FtLIL12.. Pa PtVA I E s 1_. LG Mailing Address: 853 1 LiJ .1 CRS l of TRH I■..E. l3A 6.3 b aicla& a 1 A 13d Lf ci 11 In City State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: V I 0 I- -EUC1S Day Telephone: 25A "g52-i 2.2 5 Mailing Address: 91b4 Li . m& E aril_ £1 & IC) Z I< i 1 LOA 9 6.3—L City State Zip Fax Number: 253 - g 13- 5 g t 1 E -Mail Address: kL£u9 AG Lc ELL) 1-1bierA11, Clem ELECTRICAL CONTRACTOR INFORMATION Company Name: Mailing Address: aL 4 t_,.) M Efs IZ t'2 Si Contact Person: 1 y3 LE.Lit 15 E -Mail Address: SAME flS A %0 VE f\c t= LEci .5ev Fz.E 1►Jt LEA; Contractor Registration Number: It C ELE SIO 2.5 D 1 City ? 3_ State Zip Day Telephone: 2 5a - 4 (3 - 5 % Fax Number: 253- g 13 ' 11 Expiration Date: 2 3 " i C) Valuation of Project (contractor's bid price): $ 4/...) t ©D/ . 0 3 l Scope of Work (please provide detailed information): 1 f`^L' EG u1 (J to E n)1 LiF1Ltx 1"1-.5 a 717 - LDRA eL(26os 1— Pc t-1 - Gt2Gutt L=.1L1ST1100i -2..L60 ptri,p Will service be altered? ❑ Yes Nor Adding more than 50 amps? © Yes Gi No Type of Use: 1 � W\ 1 e% t3 to ALi 1 cl Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel [9Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: 2/ Puget Sound Energy ❑ Seattle City Light H:1Applicefioms1Fonns.Appiiaoens On linel4.2007 - Electrical Permit Appiiation.doc bh Page 1 of 2 �fl �� z -o6 -13 ‘- 3 678 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Print Name: l C1 Ma in Address: Alt AI Date Application Accepted: 1. 4,- v. Date: Day Telephone: (11 1,3 3 — - Date Application Expires: City state Zip Staff Initials: H.UpplicationsWorms- Applications On Line\4.2007 - Electrical Permit Application.doc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us Parcel No.: 2623049097 Address: 500 ANDOVER PK E TUKW Suite No: Applicant: ASEMCO RECEIPT Permit Number: EL08 -471 Status: PENDING Applied Date: 04/25/2008 Issue Date: Receipt No.: R08 -01340 Payment Amount: $922.50 Initials: WER Payment Date: 04/25/2008 11:17 AM User ID: 1655 Balance: $0.00 Payee: AC ELECTRIC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 09929 922.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 738.00 000.345.832.00.0 184.50 Total: $922.50 1650 04/25 9711 TOTAL 990.50 rinr.• Rwraint -OR Pri ntRrl. 04- 2fii- 2flflR INSPECTION NO. INSPECTION RECORD Retain a copy with permit etz\Y-911 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: 4.5z. P �� W Type of Inspection: [C. 2I` Address: Sao motes, Pe. 6 Date Called: Special Instructions: Date Wanted: � a.m. p.m. Requester: Phone No: r:1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 40(1.,0 I/J Inspector: &We\ 'Date: 044 by pi $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: m -- •',A s' . ir LP -Trr- ?< . NI p. 4 . - D-Gr D 35 3 ITT -31\ r . 4 r- P ill , ___7> 0 D .___ T i-1- r\ ------------,t_rt_ -0 Xi M c.. ,..., 1 n ' A 7m rr 1>C7 =1" c) oun . 1 _._0 Z g tit -4 -- P rvi iis, rr a PANEL: A 5 SEC 2 VOLTAGE: . ' 1 ' 08V FEED FROM : A 5 SEC 1 43 44 ) 45 ) AIR COMPRESSOR a 46 47 - 48 ' 4 50 51 )VIP 70 52 53 ) 54 55 SPARE 56 57 SPARE 58 59 SPARE 60 61 SPARE 62 63 SPARE 64 64 SPARE 66 67 EAST WALL RECPT. 68 69 EAST WALL RECPT. 70 71 EAST WALL RECPT. 72 73 EAST WALL RECPT. \,...______________........___) 74 COMPRESSOR ROOM RECPT. 75 SPARE 76 COMPRESSOR ROOM RECPT. 77 SPARE 78 79 SPARE 80 81 SPARE 82 ) ) 220 OUTLET COMPRESSOR RM 83 SPARE 84 ) AC ELECTRIC SERVICE 253 -852 -0225 ASEMCO .PANEL: A 3 SEC. #1 VOLTAGE: 120V / 208V FEED FROM : M D P 1 OFFICE RECPT. 2 WHAREHOUSE RECPT. 3 OFFICE RECPT. 4 WHAREHOUSE RECPT. 5 OFFICE RECPT. 6 WHAREHOUSE RECPT. 7 OFFICE RECPT. 8 WHAREHOUSE RECPT. 9 OFFICE RECPT. 10 WHAREHOUSE RECPT. 11 OFFICE RECPT. 12 OFFICE RECPT. 13 OFFICE RECPT. 14 E F - 1 15 OFFICE RECPT. 16 INDOOR COOLING UNIT 17 MAILING OFFICE 18 ) )ENVELOPEINSERT 19 COMPUTER RM RECPT. 20 ) 21 COMPUTER RM RECPT. 22 LUNCHROOM RECPT. 23 COMPUTER RM RECPT. 24 LUNCHROOM RECPT. 25 COMPUTER RM RECPT. 26 ROOF TOP RECPT. 27 COMPUTER RM RECPT. 28 LUNCH ROOM RECPT. 29 COMPUTER RM RECPT. 30 ) ) ROOF TOP COMPRESSOR 31 ) "' , 32 ) (COMPUTER ROOM ) - �t �. 33 ) CORD DROP 34 ) W 1 ) )AQUEOUSTECHAQ -2015C 35 ) 36 ) 37 ) 38 ) ) ) 39 ) CORD DROP 40 ) 2 WEST EXHAUST FANS 41 ) / 42 ) AC ELECTRIC SERVI E 253- 852 -0225 ASEMCO .PANEL: A 3 SEC. # 2 FEED FROM : A 3 SEC 1 pactif21.1.Ara" 120V / 208V 43 CORD DROP 120 v 44 ) _ ) HOT WATER TANK L:1.5 CORD DROP 120 v 46 ) 47 SPARE 48 TIME CLOCK 49 SPARE 50 RECPTS. NORTH 51 SPARE 52 ) 53 SPARE 54 ) BATTERY CHARGER 55 SPARE 56 ) 57 SPARE 58 COMPUTER ROOM AC UNIT 59 SPARE 60 SPARE 61 SPARE 62 SPARE 63 SPARE 64 SPARE 64 SPARE 66 SPARE 67 SPARE 68 SPARE r"� 69 CORD DROP 120 v ' 70 SPARE ,--71 72 SPARE SPARE 73 WHAREHOUSE OUTLETS 74 CORD DROP 120 v 75 WHAREHOUSE OUTLETS 76 SPARE 77 WHAREHOUSE OUTLETS 78 SSPARE 79 WHAREHOUSE OUTLETS 80 SPARE 81 WHAREHOUSE OUTLETS 82 SPARE 83 WHAREHOUSE OUTLETS 84 WHAREHOUSE OUTLETS AC ELECTRIC SERVICE 253 - 852 -0225 ASEMCO PANEL: A 5 SEC 1 OLTAG • _- ... ; : - ---./ 8V - FEED FROM : M D P -. 1 C 120 v OUTLET .' 2 ) ) 3 CORD DROP 120 v OUTLET ' 4 ) JUKI 2020 E 5 CORD DROP 120 v OUTLET 6 ) - - j • 7 CORD DROP 120 v OUTLET ! 8 ) -s-- 9 CORD DROP 120 v OUTLET 10 ) MY DATA MY12E 11 CORD DROP 120 v OUTLET 12 ) f 13 CORD DROP 120 v OUTLET 14 SPARE 15 CORD DROP 120 v OUTLET 16 SPARE 17 CORD DROP 120 v OUTLET 18 SPARE 19 CORD DROP 120 v OUTLET 20 SPARE 21 CORD DROP 120 v OUTLET 22 SPARE 23 CORD DROP 120 v OUTLET 24 SPARE 25 ) _/ 26 SPARE 27 ) EXHAUST FANS (2 EAST) 28 M P M / S P M PRINTER ) 29 ) . 30 UNIVERSAL SEQUENCER '31 ERKA E 5 32 UNIVERSAL V C D ' 33 ERKA E 5 34 UNIVERSAL RADIAL 35 SPAR 36 UNIVERSAL DIP 37 ) 38 S.E. WALL OUTLETS 39 ) JUKI 2010 E 40 S.E. WALL OUTLETS 41 ) 42 S.E. WALL OUTLETS AC ELECTRIC SERVICE 253 -852 -0225 ASEMCO PANEL: P4 OLTAGE: 277 v / 480 v FEED FROM :MDP l = 1 ) _ 2 ) ) ) 3 ) A H V- 2 4) ELECTOVERT VECTRA ELYTE 5 ) 6 ) 8 ) ) ) 9 )VIP 98A 10 )ACU -2 ) ) 11 ) 12 ) 14 ) ) 15 )P -5 PANEL FEED 16 )ACU -3 ) ) 17 ) 18 ) 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 AC ELECTRIC SERVICE 253- 852 -0225 ASEMCO PANEL: P 5 FEED FROM P 4 VOLTAGE: 277 v / 480 v 1 OUTSIDE LIGHTS - NORTH 2 ) 3 OUTSIDE LIGHTS - WEST 4 ) ROLL UP DOOR # 4 W. WALL ) 5 SPARE 6 ) 7 SPARE 8 ) 9 SPARE 10 ) ROLL UP DOOR N.E. CORNER 11 ) 12 ) ) 13 ) AQUA CYCLER 14 ) ) ) 15 ) _ _ 16 )ACU -1 17 SPACE 18 ) 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 AC ELECTRIC SERVICE 253 -852 -0225 ASEMCO r May 2, 2008 • Ciz of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Kevin Lewis 804 West Meeker, Suite 102 Kent, WA 98032 RE: Letter of Incomplete Application # 1 Electrical Permit Application EL08 -471 Asemco — 500 Andover Park E Dear Mr. Lewis, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on April 25, 2008 is determined to be incomplete. Before your application can continue the plan review process the following item from the following department needs to be addressed: Building Department: Jim Benner, at 206 431 -3679, if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that three (3) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Brenda Holt Permit Coordinator Enclosures File: EL08 -471 P:\Permit Center\Incomplete Letters\2008\EL08 -471 Incomplete Ltr # 1.DOC wer 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206- 431 -3665 r i • • Tukwila Building Division Jim Benner, Electrical Inspector Determination of Completeness Memo Date: April 30, 2008 Project Name: Asemco Permit #: EL08- 471 Plan Review: Jim Benner, Electrical Inspector The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). 1. Provide present service demand per N.E.C. 220.87 and WAC 296- 46B- 901(15)(j). 2. Provide calculated load after proposed increase. 3. Provide panel schedules for all panels with load increase. Should there be questions concerning the above requirements, contact the Building Division at 206 - 431 -3670. No further comments at this time. •PEHMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -471 DATE: 06 -02 -08 PROJECT NAME: ASEMCO SITE ADDRESS: 500 ANDOVER PK E Original Plan Submittal X Response to Incomplete Letter # 1 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: B tJTlding'Divisi n� Fire Prevention Public Works ❑ Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 06-03-08 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUESITHURS RO TING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07 -01-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 •ERMIT COORD COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -471 PROJECT NAME: ASEMCO SITE ADDRESS: 500 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # DATE: 04 -25 -08 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS ALIA 1 j�C�t Biii ng I islon Public Works U Fire Prevention Structural Planning Division ❑ Permit Coordinator t.1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 04 -29 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: GO/ LETTER OF COMPLETENE($�(I4 AILED: Departments determined incomplete: Bldg GO Fire ❑ Ping ❑ PW ❑ Staff Initials: `f"' TUES/THURS ROUTING: Please Route n Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 05 -27 -08 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 • • City of Tukwila Steven M. Mullet, Mayor Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.cLtukwila.wa.us Steve Lancaster, Director Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, eta Date: 1,1? il ` D.' Plan Check/Permit Number: _Lu)2,____,________ Ea Response to Incomplete Letter # ) 0 Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Contact Person: Y--1(3 \) 1 v k_a> t n Phone Number: C1 'J53 - g3( - ocpq Summary of Revision: drr OF TUKWILA 1JUN 0 2 2000 QERMITp Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on (0-.)_-0 r kapplicationssforms- applications on Iinelnwision submittal Created: 8-13 -2004 Look Up a Contractor, Electrician or Plumber License Detail • Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License ACELESI025DF Licensee Name A C ELECTRIC SERVICE INC Licensee Type ELECTRICAL CONTRACTOR UBI 601858837 Ind. Ins. Account Id Business Type CORPORATION Address 1 804 W MEEKER ST STE 102 Address 2 City KENT County KING State WA Zip 98032 Phone 2538520225 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 3/6/1998 Expiration Date 3/6/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License CHUTIAM960L8 Master Electrician Information License CHUTIAM960L8 Name CHUTICH, ALAN M Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date CHUTICH, ALAN 01/01/1980 Bond Information Bond Page 1 of 2 https: // fortress .wa.gov /lni/bbip /printer.aspx ?License= ACELESI025DF 06/12/2008 Asemco, Inc, 500 Andover Park East Monday, April 21, 2008 49' 1 1/2" Shipping Storage #15 Shipping #14 Test Department #13 Final QA #12 Final Assembly 31' 9" X 72' Space TBD 11' 1" r --- #11 Wash #10 Wave Solder Quality Assurance #5 SMT Brink,* &vb. Nu /Clem Poly aft - -- CO #9 Solder ine #6 Board Prep IU 11. IUU IUU #8 Slide Line ._...i, li #7 Comp. Prep 4' • 49' 1 1/2" .0 13' #3 Kit Audit aterial Stores = #1 Incoming Receiving 0 co 2 1 SMT Set-Up :: • .4 :.."4.4 Al.ina•i -:•:,,,,,Wq .... . .. ';`,00....0,M,64.• ,.:...:.: Ar.: 0 .,::- ,,,....-: ::: '' .-" ''1,0 ANDOVER PARKWAY EAST - 1-8TH SCALE - DRAWN SY Timothy Ramsey PAGE 1 OF 1 SCALE 1 : 8 VAS ItOYALT.1- : •••::•0:1 58' 11" DESCRIPTION Electrical Layout #2 FILENAME PLAN VIEW - 500 ANDOVER PARKWAY EAST - 1-8TH SCALE - EQUIPMENT ELEGTRICAL 3 - 4.VSD DATE 10/10/2007 FULL FILENAME E:\500 ANDOVER PARKWAY EAST\EQUIPMENT ELECTRICAL 1 - 4\PLAN VIEW - 500 MI IIPMFNT FI FCTRICAL S - 4 VS ANDOVER PARKWAY EAST - 1-8TH SCALE - DRAWN SY Timothy Ramsey PAGE 1 OF 1 SCALE 1 : 8 REVISED 4/21/2008 APPROVED SUBMITTED 6 ft. 0.75 in. 13 ft. 3.875 in. 14 ft. 2.3757 in. 24 ft. 2.5017 in. 27 ft. 8.3765 in. 31 ft. 5 in. 85 ft. 8 in. 111 ft. 2.5015 in. 118 ft. 10.5408 in. 113ft. 7 in. SEPAFIATE PERMIT FiEQUIRED FOR: eMechanlcat Eiumbing ectrical Gas Piping l City of Tukwila BUILDING DIVISION rREVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC JUN -6 2008 ity Of Tukwila B ILDING DIVISION • ALE •OPY Permit No. Plar review approval is subject to err= and.om,. Risseeloens:pt the violation of any Approval of construction documents does not authorize code or o pi, ,..: By ze-n ,. i EU:- II. , W O f approved Fiel . . an 1111d —,1,...- is acknowledged: arer Date: Tukwila ETIOINC) DNISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. ELO&91I Page 1 RECEIVEr APR 2 52008 PERMIT CENTE- Kim M. Deanna Tim R. 1 49' 1 t /2„ Accounting Storage Asemco, Inc. 500 Andover Park East Shipping Storage #15 Shipping XOOKOIONXIC of IT Department 11' 1" 114 Si Wednesday, April 23, 2008 #14 Test Department #11 Wash #13 Final QA ■ ■ •• 158'11" !1_ N.,:,.............,,,,,..x. #12 Final Assembly 31' 9" X 72' Space TBD 411 =':.: #16Air T i Compressor 0) 9'1" iu 11V 1] r■■■■ #10 Wave Solder Quality Assurance mow #5 SMT Aquo, o Tech Aa Oru O r�m.rm, ro.iam,vcysvr " rcok.A.. L so_o, Tech IAO* ocw 118 ■ ■ ■ ■r11 ■ ••••r #9 Solder Line r as. ale. NSF #8 Slide Line 35' 4.5" 49' 1 1/2" #3 Kit Audit #7 C• mp Prep gib \1r rn W 0) IV 01 7 #1? Material Stores #4 Auto Insertio DESCRIPTION Electrical Layout #1 FILENAME UPDATED - PLAN VIEW - 500 ANDOVER PARKWAY EAST - 1 -8TH SCALE - EQUIPMENT ELECTRICAL 2 - 4.VSD DATE FULL FILENAME 10/10/2007 E :\500 ANDOVER PARKWAY EAST\EQUIPMENT ELECTRICAL 1 - 4 \UPDATED - PLAN VIEW - 500 ANDOVER PARKWAY EAST - 1 -8TH SCALE - E.' i IIPMFNT Fl FCTRICAI 2 - VSD DRAWN BY PAGE SCALE REVISED APPROVED SUBMITTED Timothy Ramsey 1 OF 1 1 :8 4/23/2008 co #1 Incoming Receiving SMT Set -Up :.e.,:,;i::?:, 32.+,'E�,;} y'y< Y3 'v N'.q: }g...; 8 , 84:..> b°wy Y. Lcnnr}.:.c;'?5£{'%'.',2 : - --,-: E±$L4.v' y . °' { to3:T;? ..%.,f, -* l:i "i:.::: ":•.1 4'•IiMi:2 .x: •.+ &.fir' {f3 id .y'Ae { L i 0) 1158' 11" 1481/. 4.5011 in. 126 ft. 3.25 in. 135 ft. 7.75 in 126 ft. 3.25 in. 95 ft. 10.5 in 83 ft. 4.5 in 71 ft. 4.25 in. 43 ft. 1.5 in. 52 ft. 9.25 in. 31 ft. 4.5 in. 18 ft. 6 in. d 0. EL*. 71 Page 1 #1 Incoming Receiving - 1 each 120 / 20 Amp Quad Drops from Ceiling #2 Material Stores - NONE #3 Kit Audit - NONE SMT Set -Up - NONE #4a Auto Insertion - NONE #4b Auto Insertion - NONE #5a SMT / MyData Line - 4 each 120 / 20 Amp Quad Drops from Ceiling #5b SMT / Juki Line - 4 each 120 / 20 Amp Quad Drops from Ceiling #6 Board Prep -1 each 120 / 20 Amp Quad Drop from Ceiling #7 Component Prep - NONE #8 Slide Line - 2 each 120 / 20 Amp Quad Drops from Ceiling #9 Solder Line - 2 each 120 / 20 Amp Quad Drops from Ceiling Quality Assurance - 2 each 120 / 20 Amp Quad Drops from Ceiling #10 Wave Solder - 1 each 120120 Amp Quad Drops from Ceiling #11 Aqueous Wash - 2 each 120 / 20 Amp Quad Drops from Ceiling #1 2 Final Assembly - NONE #13 Final QA — NONE #14 Test Department - 2 each 120 / 20 Amp Quad Drops from Ceiling #15 Shipping - 1 each 120 / 20 Amp Quad Drops from Ceiling #4a Auto Insertion Universal / Sequencer Power Requirement: 115V, 30 Amp Serial Number: 2596B 7 813841 #6b Auto Insertion Universal Axial Inserter Power Requirement: 115V, 30 Amp Serial Number: 6285 - 809109 DESCRIPTION Electrical Legend FILENAME PLAN VIEW - 500 ANDOVER PARKWAY EAST - 1 -8TH SCALE - EQUIPMENT ELECTRICAL 4 - 4.VSD DATE FULL FILENAME 10/10/2007 E:1500 ANDOVER PARKWAY EAST\EQUIPMENT ELECTRICAL 1 - 41PLAN VIEW - 500 ANDOVER PARKWAY EAST - 1 -8TH SCALE - P(I IIPMFNT Fl FCTRICAI a - 4 VS DRAWN BY PAGE SCALE REVISED APPROVED SUBMITTED Timothy th Y Ramsey 1 OF 1 1 4/23 / 2 008 Asemco, Inc. 500 Andover Park East Wednesday, April 23, 2008 #5a Line #1 Juki SMT Line Ekra E5 SMT Screen Printer Power Requirements: 230V, 50/60Hz, 2.7KW, 16 Amp Serial Number: 501669 Juki 2010 SMT Chip Shooter Power Requirement: 220V 3kVA, 50 /60Hz / 24 Amp Serial Number: 210 -L1020 Juki 2020 SMT Chip Shooter Power Requirement: 220V 3kVA, 50 /60Hz / 24 Amp Serial Number: 222 -C1592 BTU V1P98 SMT Reflow Oven Power Requirement: 480V, 50kVA, 50 /60Hz, 61 Amp Serial Number: PHFA -4 #4b Auto Insertion Universal DIP Inserter Power Requirement: 115V, 30 Amp Serial Number: 6796A #10 Electrovert Vectra Elite Wave Solder Process Electrovert / Vectra Elite Power Requirement: 440 -480V, 3 phase, 54.9kVA, 60Hz, 60 Amp Serial Number: VC2 -14660 #16 Air Compressor Ingersoll Rand T -30 Air Compressor Power Requirement: 200 VAC / 3 Phase / 60 Hz / 74 Amp Serial Number: Pending Ingersoll Rand TS100 Air Dryer Power Requirement: 115 VAC / 20 Amp Serial Number: DR10015687- 062304 #5b Line #2 MyData SMT Line MPM SPM SMT Screen Printer Power Requirement: 115V, 10 Amp Serial Number: 7648 MyData MY12E SMT Chip Shooter Power Requirement: 3x210V / 121V AC +1 -10 %, 50/60Hz, 3x2.2kVA / 16 Amp Serial Number: 13548 BTU VIP70 SMT Reflow Oven Power Requirement: 208V, 31 kVA, 50 /60Hz, 80 Amp Serial Number: ASWA #4b Auto Insertion Universal Radial inserter Power Requirement: 115V, 30 Amp Serial Number: 6358 #11 Aqueous Wash Station Technical Devices Nu / Clean Poly SMT Power Requirement: 208 3 phase, 3PHZ, 60Hz, 174.4 Amp Serial Number: 4996 -350 Separation Tech / Aqua Cycler 118 Power Requirement: 460V, 3 phase, 60Hz, 24 Amp Serial Number: n/a Aqueous Tech / AO-2015C Stencil Cleaner Power Requirement: 208V, 50 Amp Serial Number: 6716 101` 5. (ac ' e .,..+ -' : ^;L tr. >:•. F: E *SL:;f.Akiii'iS:ii•}ii,'i :-: •.::::. -' �� i `.y 1 + +:.: ?•:- .::•:' -:_ :�:::::::: is 3"1 7 ELO841i Page 1 RECEIVE( APR 2 5 2008 PERMIT CENTEi-