Loading...
HomeMy WebLinkAboutPermit EL08-0486 - WESTFIELD SOUTHCENTER MALL - EXPRESSEXPRESS 1070 SOUTHCENTER MALI. ELO8-486 Parcel No.: 6364200010 Address: Suite No: City* Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us ELECTRICAL PERMIT 1070 SOUTHCENTER MALL TUKW Permit Number: Issue Date: Permit Expires On: EL08 -486 08/15/2008 02/11/2009 Tenant: Name: EXPRESS Address: 1070 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST , BLOOMINGTON MN Contractor: Name: HAGGARD ELECTRICAL CONTRACTORS LLC Address: 16702 65 AV SE , SNOHOMISH WA Contractor License No: HAGGAEC960DA Phone: Phone: 800 541 -0821 Phone: 425 - 949 -4004 Expiration Date: 03/01/2010 DESCRIPTION OF WORK: NEW LIGHTING, CIRCUITS, RECEPTACLES, SWITCHES Value of Electrical: $75,000.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of constructio Signatur Print Name: $1,502.50 2005 Date: C, [CIA ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this electrical permit. Date: U///67! G This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -486 Printed: 08-15 -2008 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us PERMIT CONDITIONS Parcel No.: 6364200010 Address: 1070 SOUTHCENTER MALL TUKW Suite No: Tenant: EXPRESS Permit Number: EL08 -486 Status: ISSUED Applied Date: 04/29/2008 Issue Date: 08/15/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this pe resume to give authority to violate or cancel the provision of any other work or local laws regulating ction or the pe ormanc work. Signature: Date: O /i� /02.4 Print Name: 1):)/ doc: Cond -Elec EL08 -486 Printed: 08-15 -2008 CITY OF TUKWILIP Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. f3J V V {t ` Vi yob- IO( (For office use only) Project No. ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 10-10 Ck..X.t W_enter- MCIal King Co Assessor's Tax No.: (p3fa420 - 0O \ tp Suite Number: 332 Floor: Tenant Name: eXtpCeSS Property Owners Name: V `68 Cbe `ik e v) New Tenant: Yes 1 I..No Mailing Address: 11CoO\ Vs) ∎\Slri 't-Q_ Q. -SOSI LOS PrecAeNeS, CR cjbb2.S State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: l'IneN c_e e.v\t Day Telephone: 'iObisT'-% 1- Cell Mailing Address: 1120 EES* 2:OAV1 Sit-veer- ..Like - \ \, Q\pphnxYJ *bv1 t 1N `�Za City State Zip E -Mail Address:A∎01 , t2NA CSC r e •LOYYI Fax Number: CISZ )S'S4- - 4.010°I ELECTRICAL CONTRACTOR INFORMATION Company Name: T. $ - �• Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 'j CO Scope of Work (please provide detailed information): M2A-43 ltghtj�q (jam ti eS StoileheS •) ��JJ Will service be altered? ❑ Yes ® No Adding more than 50 amps? ❑ Yes ❑ No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Remodel ® Tenant Improvement ❑ Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: gPuget Sound Energy Seattle City Light H:\ApplicationsTorms- Applications On Line'4 -2007 - Electrical Permit Application.doc Page 1 of 2 bh ti RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added /altered circuits) ❑ Service change with added /altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added /altered without service change $50.00 (up to 5 circuits) ❑ Circuits added /altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI- FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) 558.00 ❑ Temporary service (generator) 575.00 ❑ Manufactured /mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: Date: 412114 4 Print Name: 1"' ��.qq,,, 4 `hSIC Day Telephone: ' *Of °22- a LD .►GIN A-44 s r4-za . Mailing Address: I it t 0111 - a I( IDate Application Accepted: 0tt12I1� City State Zip Staff Initials: Date Application Expires: (0121 101 H:\ Applications \Frrms - Applications On Line \4-2007 - Electrical Pcnmt Application.doc bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http: //www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -486 Address: 1070 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 04/29/2008 Applicant: EXPRESS Issue Date: Receipt No.: R08 -02957 Payment Amount: $1,202.00 Initials: JEM Payment Date: 08/15/2008 09:18 AM User ID: 1165 Balance: $0.00 Payee: HAGGARD ELECTRICAL CONTRACTORS TRANSACTION LIST: Type Method Descriptio Amount Payment Check ACCOUNT ITEM LIST: Description 15696 1,202.00 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.0 1,202.00 Total: $1,202.00 rinr. RArnint -OR Printari• OR-15 -2008 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 -431 -3665 Web site: http://www.citukwi/a.wa.us SET RECEIPT RECEIPT NO: R08 -01394 Initials: JEM User ID: 1165 Payee: ELDER -JONES Payment Date: 04/29/2008 Total Payment: 2,859.25 SET ID: S000001014 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount D08 -235 2,346.50 486 300.50 165.25 PGO8 -137 47.00 TOTAL: 2,859.25 TRANSACTION LIST: Type Method Description Amount Payment Check 51321 2,859.25 TOTAL: 2,859.25 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 300.50 000/345.830 2,558.75 TOTAL: 2,859.25 1770 04/29 9711 TOTAL 285925 n..... corer me nc INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 koS- Ligb Project: G piz Type of Inspection: ` I X Address: 1070 ti Date Called: Special Instructions: 00 Date Wanted: % f/ c a. /� Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: c), 100- ,or‘15 h Ail) � (v\iivt- Inspector: 6044t-ic Date: bti J ogial ❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit Ct -o' -�6 PERMIT NO. / (206)431 -367p Project: i i� 55 Type of Inspection: 2 r 0 \ Address: 1 010 11644, Date Called: Special Instructions: Date Wanted: '° 2j a . . Requester: Phone No: EjApproved per applicable codes. El Corrections required prior to approval. COMMENTS: 0 - -TO OCcUP1 ("impair l Ai S ► U.w4TTl OJ 0 F LAG Etc oal G604 i rJ1 4CCJ - 1 Inspector: -1;,/ /3(-v\ij 61\ ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: / 42-3 3 /IV Receipt No.: Date: /3Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ,! CITY OF TUKWILA BUILDING DIVISION J�\( 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3610 s Project: t PROS Type of Inspection: �oo� \ Address: 1 010 tint/ Date Called: Special Instructions: Date Wanted: 0/1 En. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 'la1/41c0.1 irk Inspector: Date: r 0 ]f M ri$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: LA INSPECtION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION le- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: �� G X G Type of Inspection: v0 � 3 Address: 1070 5TRCI A,• Date Called: Special Instructions: Date Wanted: ?/,, n. Requester: Phone No: ElApproved per applicable codes. EICorrections required prior to approval. COMMENTS: PA U•14- - 0,4.,E�S M10 7 gaK c.6 .4c) Inspector: J•..J 1 1 &' Q ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 01 fZ4 k Receipt No.: Date: 3 INSPECTION RECORD Retain a copy with permit IA-VIP PERMIT NO. al CITY OF TUKWILA BUILDING DIVISION A 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -367 INSPECTION NO. Project: ���n �5 I " Type of Inspection: � 003 ''�.l Address: 10"10 r'1k. Date Called: Special Instructions: Date Wanted: (�A jr 1 p.m` Requester: Phone No: ElApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Sa1. -5 A t D 143 asiQmt1 (o 2-tDoc Inspector: 464,10, Date: m /11 O(,, El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit PERMIT t10. g. (206)431 -36,7 Project: E rra -( "5) Type of Inspection: 7003 ‘4,4,... Address: 1070 Pi 414, Date Called: -5-rb ick Rogir 13c.FFl r -- ,u. ( k)2 5e Fr t TS Special Instructions: Date Wanted: q 0 �/ ei. Requester: Phone No: 4. Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: \%A Q- • lc • — Wes, — G`9rkoo -5-rb ick Rogir 13c.FFl r -- ,u. ( k)2 5e Fr t TS pc. re7' co/K S4 -i.c5 E uDS Inspector: H &14A/6 ' Date: 07/01 o ❑$60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: INSPECTION RECORD Retain a copy with permit li,DV_ t IT 6 INSPEITION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: f WO -tea Type of Inspection: OO 3 Address: 1074 tittki Date Called: Special Instructions: Date Wanted: V/2- r In- Requester: Phone No: EiApproved per applicable codes. El Corrections required prior to approval. COMMENTS: • Vi 1 tibud5 (Inspector: 1\I / $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 2 /try Receipt No.: ,Date: 06 Washington State Nonresidential Energy Code Compliance Form 1 terior Lighting Summary LTG-INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address EXPRESS - WESTFIELD SOUTHCENTER Date 4/18/2008 1070 SOUTHCENTER MALL For Building `"■nA it . . Department Use SEATTLE, WASHINGTON 98188 m f^ (*::776:-/ Applicant Name: SHREMSHOCK ENGINEERING, INC. n Applicant Address: 6130 SUNBURY RD. WESTERVILLE OHIO 43065 '._.....-.. REVIEWED 1O co M ®t IA Applicant Phone: ..... 614 - 545 -4550 Project Description ❑ Plans requrements. IncludNFPA 70 - NE J `j ❑ New Building ❑ Addition ' Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option • Lighting Power Allowance Prescriptive 9 9 Syst ®ms (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces c " 2008 0 Analysis early on plans�:Nh 1 dV Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting City-Of Tukwila ❑ Less than 60% of the fixtures new, installed wattage not increased, & ipa(i 1'et ; Negravisi Maximum Allowed Lighting Wattage R JCE Location (floor /room no.) Occupancy Description Allowed Watts per ft2,,,,, Area in ft2 Allowed x Area SALES RETAIL 3.00 7023.0 21069.0 NONSALES STORAGE AREA 0.50 1221.0 610.5 RESTROOM RESTROOM 0.80 127.0 101.6 OFFICE OFFICE 1.00 60.0 60.0 ** From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 21841.1 Provosed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed SALES TRACK 343 50.0 17150.0 SALES C2 - 4" RECESS HALOGEN 21 35.0 735.0 SALES H5 - 4" RECESS QUARTZ HALOGEN 84 20.0 1680.0 SALES B6 - 4" RECESSED MR16 14 35.0 490.0 SALES BQ - 3" RECESSED MR16 8 35.0 280.0 SALES A9 - 7° RECESSED HALOGEN 5 75.0 375.0 SALES A4 - 6° RECESSED COMPACT FLUORESCENT 2 36.0 72.0 NONSALES A4 - 6" RECESSED COMPACT FLUORESCENT 8 36.0 288.0 NONSALES FG - 4', 1 LAMP FLUORESCENT 3 32.0 96.0 NONSALES FR - 4', 1 LAMP FLUORESCENT 2 32.0 64.0 NONSALES FT - 8', 2 LAMP FLUORESCENT /+ r 1 58.0 58.0 NONSALES FU - 12', 3 LAMP FLUORESCENT ROF Ti crnraFr� I 3 � 85.0 255.0 NONSALES FW - 16', 4 LAMP FLUORESCENT 1 112.0 112.0 OFFICE ��� N1 - 1'x4', 1 LAMP FLUORESCENT L�OV 1 32.0 32.0 RESTROOM A4 - 6" RECESSED COMPACT FLUORESCENT PERMIT CENTER 4 36.0 144.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 21831.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. N UN, L-1149 2006 Washington State Nonresidential Energy Code Compliance Form Interi "or Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: 00 Warehouses, storage areas or aircraft storage hangers C) Other Q ualification Checklist Note: If occupancy type is 'Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) EI Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures non - lensed with a) 1 or 2 two lamps, b) reflector ures which are ) p ) or louvers, c) 5 -60 watt T -1, T -2, T -4, T -5, T -8 lamps, and d) hard -wired elec- tropic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings. office /administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5•711 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stations" 1.0 Cafeterias, fast food establishments5, restaurants /bars5 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spaces 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies • 1.2 Transportation 1.0 Hotel /motel 1.0 Warehouses'', storage areas 0.5 Hotel banquet/conference /exhibition halV4 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries5 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. 2006 Washington State Nonresidential Energy Code Compliance Form Project Summary PRJ -SUM: 2006 Washington State Nonres dential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 1 - EXPRESS AT WESTFIELD SOUTHCENTER Date 4/18/2008 2 - 1070 SOUTHCENTER MALL For Building Department Use 3 - SEATTLE, WA 98188 Applicant Name: 4 - SHREMSHOCR ENGINEERING ICN. Applicant Address: 5 -6130 S, SUNBURY RD. WESTERVILLE OH, 43081 Applicant Phone: 6 - (614) 545 -4550 pre-mi! ,f_C rit1,6 REVIEWED FOR CODE COMPLIANCE NF ®E - J 2008 Cstiltlef ukwila B IIDING DIVISION CITY OF TIUKIMLA AI-1H 2 9 2008 PERMIT CENTER fi,osi4101)(0 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary 2006 Washington State Nonresidential Energy Code Compliance Forms MECH -SUMS Revised July 2007 Project Info Project Address 1 - EXPRESS AT WESTFIELD SOUTHCENTER Model No.1 Date 4/18/2008 Total CFM 2 - 1070 SOUTHCENTER MALL SEER or EER IPLV3 For Building Dept. Use ACCU -1 3 - SEATTLE, WA 98188 TTA240 237660 Applicant Name: 4 - SHREMSHOCX ENGINEERING ICN. 9.70 170750 Applicant Address: 5 -6130 0, SUNBURY RD. WESTERVILLE OH, 43081 Applicant Phone: 6 - (614) 545 -4550 2265 Project Description Briefly describe mechanical system type and features. Includes Plans SPLIT DX SYSTEM. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location ACCU -1 TRANE (CONDENSER) TTA240 237660 8000 22665 9.70 170750 ROOF AHU -1 TRANE (AIR HANDLER) LAPCAA14F 193790 8000 2265 ABOVE CEILING Heating Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency.' AHU -1 TRANS LAPCAA14F 193790 8000 22665 50KW ELEC 170750 Fan Equipment Schedule Equip. ID Brand Name' Model No.1 CFM SP' HP /BHP Flow Controls Location of Service EF -1 LOREN COOK GEMINI 122 75 cv RESTROOMS 'If available. 2 As tested accord ng to Table 14 -1A through 14 -1G. 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: ✓ Constant vol? 1 ✓ 1 Air cooled? [ Packaged sys? ❑ <20,000 Btuh? ✓ Split system? ✓ Economizer included? If Heating Only: g y' o ❑ <5000 cfm? ❑ <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( STAR Heating Only Heating /Cooling or Cooling Only Reference Section 1421 Yes — Yes* No Yes Reference Section 1423 pfSimple System Allowed (section 1420) No otal Ca.. wo economize <240,000 Btuh or 10 %? Yes - —No Yes -- Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary MECH -SUM 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address 1 - EXPRESS AT WESTFIELD SOUTHCENTER Model No.1 Date 4/18/2008 Total CFM 2 - 1070 SOUTHCENTER MALL SEER or EER For Building Dept. Use Location 3 - SEATTLE, WA 98188 TRANE Applicant Name: 4 - SHREMSHOCR ENGINEERING ICN. 8000 Applicant Address: 5 -6130 8, SUNBURY RD. WESTERVILLE OH, 43081 Applicant Phone: 6 - (614) 545 -4550 Project Description Briefly describe mechanical system type and features. Includes Plans SPLIT DX SYSTEM. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option 0 Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex systems.) Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Brand Name' Model No.1 Capacity2 Btu /h Total CFM OSA CFM or Econo? SEER or EER IPLV3 Location ACCU -1 TRANE TTA240 237660 8000 22665 9.70 170750 ROOF Heating Equipment Schedule Equip. ID Brand Name Model No.1 Capacity2 Btu /h Total CFM OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 AHU -1 TRANE LAPCAA14F 193790 8000 22665 170750 Fan Equipment Schedule Equip. ID Brand Name Model No.1 CFM SP' HP /BHP Flow Controls Location of Service EP -1 LOREN COOK GEM 'lf available. 2 As tested accord ng to Table 14 -1A through 14-1G. 3 If required. " COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Summary (back) MECH -SUM System Description See Section 1421 for full description of Simple System qualifications. If Heating /Cooling or Cooling Only: 0 Constant vol? •/ Air cooled? Packaged sys? ❑ <20,000 Btuh? Ea Split system? • Economizer included? If Heating Only: ❑ <5000 cfm? ❑ <70% outside air? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating Only Heating /Cooling or Cooling Only Reference Section 1421 J Yes — Yes* Yes Reference Section 1423/ Simple System Allowed (section 1420) otal Ca.. wo economize <240,000 Btuh or 10 %? t Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2006 Washington State Nonresidential Energy Code Compliance Form Electric Motors MECH -MOT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 1 - EXPRESS AT WESTFIELD SODTHCENTER Date 4/18/2008 Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors from 1 hp to 200 hp having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). For Building Department Use Motor No. or Location HP Type (open /closed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency AHD -1 7- 1/2 closed SUPPLY AIR 1800 8900.0% Minimum Nominal Full -Load Efficiency Synchronous Speed (RPM) HP 1.0 1.5 2.0 3.0 5.0 7.5 10 15 20 25 30 40 50 60 75 100 125 150 200 Open Motors Closed Motors 3,600 1,800 1,200 3,600 1 1,800 1,200 Efficiency ( %) Efficiency ( %) - 82.5 800 75.5 82.5 80.0 82.5 84.0 84.0 82.5 84.0 85.5 84.0 84.0 85.5 84.0 84.0 86.5 84.0 86.5 86.5 85.5 87.5 87.5 85.5 87.5 87.5 87.5 87.5 87.5 87.5 88.5 88.5 88.5 89.5 89.5 88.5 89.5 90.2 89.5 89.5 89.5 89.5 91.0 90.2 90.2 91.0 90.2 90.2 91.0 91.0 90.2 91.0 90.2 91.0 91.7 91.7 91.0 924 91.7 91.0 92.4 92.4 91.0 92.4 91.7 91.7 93.0 93.0 91.7 93.0 93.0 92.4 93.0 93.0 92.4 93.0 93.0 93.0 93.6 93.6 93.0 93.6 93.6 93.0 94.1 93.6 93.0 94.1 93.6 93.0 94.1 94.1 93.6 94.5 94.1 93.6 94.5 94.1 94.5 94.5 94.1 93.6 95.0 94.5 94.5 95.0 95.0 94.5 95.0 94.5 95.0 95.0 95.0 Exceptions: 1. Motors in systems designed to use more than one speed of a multi -speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14 -1B). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (i.e. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment is with a less- efficient motor and there is no energy - efficient motor option). For motors claiming an exception, list motor and note which exception applies. 2006 Washington State Nonresidential Energy Code Compliance Form 'Mech+anical Permit Plans Checklist MECH -CHK' 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address 1 - EXPRESS AT WESTFIELD SOUTHCENTER Date 4/18/2008 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401 -1424) 1411 Equipment performance n.a. 1411.4 Pkg. elec. htg.& clg. List heat pumps -on schedule yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency a. a. 1411.1 Combustion htg. Indicate intermittent ignition, flue /draft damper & jacket loss 1412 HVAC controls yes 1412.1 Temperature zones Indicate locations on plans yes 1412.2 Deadband control Indicate 5 degree deadband minimum yes 1412.3 Humidity control Indicate humidistat yes 1412.4 Automatic setback Indicate thermostat with night setback and 7 diff. day types yes 1412.4.1 Dampers Indicate damper location and auto. controls & max. leakage yes 1412.4.2 Optimum Start Indicate optimum start controls no 1412.5 Heat pump control Indicate microprocessor on thermostat schedule n. a. 1412.6 Combustion htg. Indicate modulating or staged control yes 1412.7 Balancing Indicate balancing features on plans 1412.8 Ventilation Control Indicate demand control ventilation for high - occupancy areas yes 1422 Thermostat interlock Indicate thermostat interlock on plans yes 1423 Economizers Equipment schedule 1413 Air economizers yes 1413.1 Air Econo Operation Indicate 100% capability on schedule yes 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb n.a. 1413.2 Water Econo Doc Indicate clg load & water econoe & clg tower performance yes 1413.3 Integrated operation Indicate capability for partial cooling yes 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting systems yes 1414.1 Duct sealing Indicate sealing necessary yes 1414.2 Duct insulation Indicate R -value of insulation on duct yea 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements yes 1416.2.1 Commissioning Provide commissioning plan 1416.2.2 -3 Sys.Bal & Func.Test Indicate air and water system balancing & functional testing yes 1416.2.4 Commissioning Indicate O &M manuals, record drawings, staff training yes 1416.2.5 Comm. Report Indicate requirements for prelim. & final commissioning report a. a. 1434 Separate air sys. Indicate separate systems on plans yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer SERVICE WATER HEATING AND HEATED POOLS (Sections 1440 -1454) 1440 Service water htg. yes 1441 Elec. water heater Indicate R -10 insulation under tank yes 1442 Shut -off controls Indicate automatic shut -off yes 1443 Pipe Insulation Indicate R -value of insulation on piping n.a. 1452 Heat Pump COP Indicate minimum COP of 4.0 n.a. 1452 Heater Efficiency Indicate pool heater efficiency a.a. 1453 Pool heater controls Indicate switch and 65 degree control n.a. 1454 Pool covers Indicate vapor retardant cover n.a. 1454 Pools 90+ degrees Indicate R -12 pool cover If "no' is circled for any question, provide explanation: 2006 Washington State Nonresidential Energy Code Compliance Form Mechanical Permit Plans Checklist MECH -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Mechanical - General Requirements 1411.1 General: Equipment shall have a minimum performance at the specified rating conditions not less than the values shown in Table 14 -1A through 14 -1G. If a nationally recognized certification program exists for a product covered in Tables 14-1A through 14-1G, and it includes provisions for verification and challenge of equipment efficiency ratings, then the product shall be listed in the certification program. Gas -fired and oil -fired forced air fumaces with input ratings > 225,000 Btu /h (65 kW) and all unit heaters shall also have an intermittent ignition or interrupted device (IID), and have either mechanical draft (including power venting) or a flue damper. A vent damper is an acceptable alternative to a flue damper for furnaces where combustion air is drawn from the conditioned space. All fumaces with input ratings > 225,000 Btu /h (65 kW). including electric fumaces, that are not located within the conditioned space shall have jacket losses not exceeding 0.75% of the input rating. 1411.2 Rating Conditions: Cooling equipment shall be rated at ARI test conditions and procedures when available. Where no applicable procedures exist, data shall be fumished by the equipment manufacturer. 1411.3 Combination Space and Service Water Heating: For combination space and service water heaters with a principal function of providing space heat, the Combined Annual Efficiency (CAE) may be calculated by using ASHRAE Standard 124 -1991. Storage water heaters used in combination space heat and water heat applications shall have either an Energy FActor (EF) or a CAE of not less than the following: 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooting with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1 Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stones in height. 'I A1�1 .4 ' flwal...,,n. C41..4 Pnnlrnle • LJaafinn anrf .nnnnn cl.ctomc 'fh riacinn c.,nnh. 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer. at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 7 aro ientatart fmm tho oxtorinr with an antnmatio chat -nff riamnar nmmnlvinn EF CAE < 50 gal storage 0.58 0.71 50 to 70 gal storage 0.57 0.71 > 70 gal storage 0.55 0.70 1411.4 Packaged Electric Heating and Coo ing Equipment: Packaged electric equipment providing both heating and cooting with a total cooling capacity greater than 20, Btu /h shall be a heat pump. Exception: Unstaffed equipment shaelters or cabinets used solely for personal wireless service facilities. 1412 Controls 1412.1 Temperature Controls: Each system shall be provided with at least one temperature control device. Each zone shall be controlled by individual thermostatic controls responding to temperature within the zone. At a minimum, each floor of a building shall be considered as a separate zone. 1412.2 Deadband Controls: When used to control both comfort heating and cooling, zone thermostatic controls shall be capable of a deadband of at least 5 degrees F within which the supply of heating and cooling energy to the zone is shut off or reduced to a minimum. Exceptions: 1. Special occupancy, special usage, or code requirements where deadband controls are not appropriate. 2. Buildings complying with Section 1141.4, if in the proposed building energy analysis, heating and cooling thermostat setpoints are set to the same temperature between 70 degrees F and 75 degrees F inclusive, and assumed to be constant throughout the year. 3. Thermostats that require manual changeover between heating and cooling modes. 1412.3 Humidity Controls: If a system is equipped with a means for adding moisture, a humidistat shall be provided. 1412.4 Setback and Shut -Off: HVAC systems shall be equipped with automatic controls capable of accomplishing a reduction of energy use through control setback or equipment shutdown during periods of non -use or altemate use of the spaces served by the system. The automatic controls shall have a minimum seven -day clock and be capable of being set for seven different day types per week. It must retain programming and time for a power loss of 10 hours and include an accessible manual override of up to 2 hours. Exceptions: 1. Systems serving areas which require continuous operation at the same temperature setpoint. 2. Equipment with full load demands of 2 kW (6,826 Btu /h) or less may be controlled by readily accessible manual off-hour controls. 3. Systems controlled by an occupant sensor that is capable of shutting the system off when no occupant is sensed for a period of up to 30 minutes. 4. Systems controlled solely by a manually operated timer capable of operating the system for no more than two hours. 1412.4.1 Dampers: Outside air intakes, exhaust outlets and relief outlets serving conditioned spaces shall be equipped with dampers which close automatically when the system is off or upon power failure. Stair shaft and elevator shaft smoke relief openings shall be equipped with normally open (fails to open upon loss of power) dampers. These dampers shall remain closed until activated by the fire alarm system or other approved smoke detection system. Exceptions: 1 Systems serving areas which require continuous operation. 2. Combustion air intakes. 3. Gravity (nonmotorized) dampers are acceptable in buildings less than 3 stories in height. 4. Gravity (nonmotorized) dampers are acceptable in exhaust and relief outlets in the first story and levels below the first story of buildings three or more stones in height. 'I A1�1 .4 ' flwal...,,n. C41..4 Pnnlrnle • LJaafinn anrf .nnnnn cl.ctomc 'fh riacinn c.,nnh. 1412.8 Ventilation Controls for High- Occupancy Areas: Demand control ventilation (DCV) is required for spaces that are larger than 500 ft2, have a design occupancy for ventilation of greater than 40 people for 1000 ft2 of floor area, and are served by systems with one or more of the following: a. An air -side economizer, b. Automatic modulating control of the outdoor air damper, or c. A design outdoor airflow greater than 3000 cfm. Exceptions: 1.Systems with energy recovery complying with Section 1436. 2. Multiple -zone systems without direct - digital control of individual zones communicating with a central control panel. 3. Systems with a design outdoor airflow less than 1200 cfm. 4. Spaces where the supply airflow rate minus any makeup or outgoing transfer air requirement is less than 1200 cfm. 1413 Air Economizers 1413.1 Operation: Air economizers shall be of automatically modulating outside and return air dampers to provide 100 percent of the design supply air as outside air to reduce or eliminate the need for mechanical cooling. Water economizers shall be capable of providing the total concurrent cooling load served by the conneted terminal equipment lacking airside economizer. at outside air temperatures of 45 °F dry- bulb /40 °F wet -bulb and below. For this calculation, all factors including solar and internal load shall be the same as those used for peak load calculations, except for the outside temperatures. Exception: Water economizers using air - cooled heat rejection equipment may use a 35 °F dry-bulb outside air temperature for this calculation. This exception is limited to a maximum of 20 tons per building. 1413.2 Documentation: Water economizer plans submitted for approval shall include the following information: 1. Maximum outside air conditions for which economizer is sized to provide full cooling. 2. Design cooling load to be provided by economizer at this outside air condition. 3. Heat rejection and terminal equipment performance data including model number, flow rate, capacity, entering and leaving temperature in full economizer cooling mode. 1413.3 Integrated Operation: Air economizers shall be capable of providing partial cooling even when additional mechanical cooling is required to meet the remainder of the cooling load. Exceptions: 1. Individual, direct expansion units that have a rated capacity less than 65,000 Btu /h and use nonintegrated economizer controls that preclude simultaneous operation of the economizer and mechanical cooling. 2. Water-cooled water chillers with waterside economizer. 1413.4 Humidification: If an air economizer is required on a cooling system for which humidification equipment is to be provided to maintain minimum indoor humidity levels, then the humidifier shall be of the adiabatic type (direct evaporative media or fog atomization type). Exceptions: 1. Health care facilities where WAC 246 - 320 -525 allows only steam injection humidifiers in ductwork downstream of final filters. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment with a capacity over 225,000 Btu /h shall have modulating or staged combustion control. 2. Systems with water economizer 3. 100% outside air systems with no provisions for air recirculation to the central supply fan. 4. Nonadiabatic humidifiers cumulatively serving no more than 10% of a building's air economizer capacity as measured in cfm. This refers to the system cfm serving rooms with stand alone or duct mounted humidifiers. 1414 Ducting Systems 1414.1 Sealing: Duct work which is designed to operate at pressures above 1/2 inch water column static pressure shall be sealed in accordance with Standard RS -18. Extent of sealing required is as follows: 1. Static pressure: 1/2 inch to 2 inches; seal transverse joints. 2. Static pressure: 2 inches to 3 inches; seal all transverse joints and longitudinal seams. 3. Static pressure: above 3 inches; seal all transverse joints, longitudinal seams and duct wall penetrations. Duct tape and other pressure sensitive tape shall not be used as the primary sealant where ducts are designed to operate at static pressures of 1 inch W.C. or greater. 1414.2 Insulation: Ducts and plenums that are constructed and function as part of the building envelope, by separating interior space from exterior space, shall meet all applicable requirements of Chapter 13. These requirements include insulation installation, moisture control, air leakage, and building envelope insulation levels. Unheated equipment rooms with combustion air louvers must be isolated from the conditioned space by insulating interior surfaces to a minimum of R -11 and any exterior envelope surfaces per Chapter 13. Outside air ducts serving individual supply air units with less than 2,800 cfm of total supply air capacity shall be insulated to a minimum of R -7 and are not considered building envelope. Other outside air duct runs are considered building envelope until they, 1. connect to the heating or cooling equipment, or 7 aro ientatart fmm tho oxtorinr with an antnmatio chat -nff riamnar nmmnlvinn vwtGLJ 111 wIG IuJl Jtwly clew IGVCIJ ueiuw MC 111 L Jtwl y vi uWIUWUyJ ���• •'-••" "•" ° °••_.__.__ __.__...� _ _ _,-_ _,. three or more stories in he b6 Washington State Nonresidential Eher§rett58 tbii10112Theecl2bPfhecluipment, or 1412.4.2 Optimum Start Controls: Heating and cooling systems with design supply 2. are isolated from the exterior with an automatic shut -off damper complying a air capacities exceeding 10,000 cfm shall have optimum start controls. Optimum with Section 1412.4.1. start controls shall be designed to automatically adjust the start time of an HVAC Once outside air ducts meet the above listed requirements, any runs within system each day to bring the space to desired occupied temperature levels conditioned space shall comply with Table 14 -5 requirements. immediately before scheduled occupancy. The control algorithm shall, as a Other ducts and plenums shall be thermally insulated per Table 14 -5. minimum, be a function of the difference between space temperature and occupied Exceptions: setpoint and the amount of time prior to scheduled occupancy. 1. Within the HVAC equipment. 1412.5 Heat Pump Controls: Unitary air cooled heat pumps shall include microprocessor controls that minimize supplemental heat usage during start-up, set 2. Exhaust air ducts not subject to condensation. up, and defrost conditions. These controls shall anticipate need for heat and use 3. Exposed ductwork within a zone that serves that zone. compression heating as the first stage of heat. Controls shall indicate when 1415 Piping Systems supplemental heating Is being used through visual means (e.g., LED indicators). 1415.1 Insulation: Piping shall be thermally insulated in accordance with Table 14 -6. 1412.6 Combustion Heating Equipment Controls: Combustion heating equipment Exception: Piping installed within unitary HVAC equipment. with a capacity over 225,000 Btu /h shall have modulating or staged combustion Water pipes outside the conditioned space shall be insulated in accordance with control. 000 Washington State Plumbing Code (WAC 51 -26) EXCEPTIONS: 1. Boilers. 2. Radiant heaters. 1416 Completion Requirements (Refer to NREC Section 1416 and the Building 1412.7 Balancing: Each air supply outlet or air or water terminal device shall have Commissioning Guidelines, published by the Building Commissioning Association, a means for balancing, including but not limited to, dampers, temperature and for complete text and guidelines for building completion and commissioning pressure test connections and balancing valves. requirements.) 03 -13 -2009 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director TIM SCHENK 1120E 80 ST BLOOMINGTON MN 55420 RE: Permit No. EL08 -486 1070 SOUTHCENTER MALL TUKW Dear Permit Holder: In reviewing our current records the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code, every permit issued by the Building Division under the provisions of the code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit issuance, or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days. Based on the above, you are hereby advised to: Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection. This inspection is intended to determine if substantial work has been accomplished since issuance of the permit or last inspection; or if the project should be considered abandoned. If such determination is made, the International Codes, Uniform Plumbing/Fuel Gas Code and/or the National Electrical Code does allow the Building Official to approve one extension of time for an additional period not exceeding 180 days. Extension requests must be in writing and provide satisfactory reasons why circumstances beyond the applicants control have prevented action from being taken. In the event you do not call for the above inspection and receive an extension prior to 04/21/2009 , your permit will become null and void and any further work on the project will require a new permit application and associated fees. Thank you for your cooperation in this matter. Sincerely, 1—a;912 qvitiftir Bill Rambo Permit Technician xc: Permit File No. EL.08 -486 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 SPERMITCOORDCOP\ • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: E1_08 -486 DATE: 04 -29 -08 PROJECT NAME: EXPRESS SITE ADDRESS: 1070 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Bul ding 1 vision Public Works n Fire Prevention Structural Planning Division nPermit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 7 Incomplete n DUE DATE: 05-01 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 05-29-08 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Untitled Page • • Page 1 of 2 Electrical Contractor A business licensed by Lai to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. HAGGARD ELECTRICAL CONTRS LLC Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company HAGGARD ELECTRICAL CONTRS LLC 4259494004 16702 65TH AVE SE SNOHOMISH WA 98296 SNOHOMISH LIMITED LIABILITY COMPANY UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Separation Date Previous License Next License Associated License Specialty 1 Specialty 2 602357747 ACTIVE HAGGAEC960DA ELECTRICAL CONTRACTOR 3/1/2004 3/1/2010 HAGGAR*964CL GENERAL UNUSED ADMINISTRATOR INFORMATION License HAGGAR*964CL Name HAGGARD, RYAN Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date HAGGARD, RYAN L PARTNER /MEMBER 03/01/2004 HAGGARD, ELIZABETH A PARTNER /MEMBER 03/01/2004 Bond Information https: / /fortress. wa. gov /lni/bbip/Detai 1. aspx ?License= HAGGAEC960DA 08/15/2008 DIVISION 26 - ELECTRICAL SECTION 26 00 00 - BASIC ELECTRICAL REQUIREMENTS A. NOTES 1. THE ABBREVIATION ESD &C WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS AND /OR SPECIFICATIONS SHALL REFER TO "EXPRESS STORE DESIGN AND CONSTRUCTION ". ANY REFERENCE TO TENANT'S PROJECT MANAGER OR FURNISHED BY ANY OF THE ABOVE REFERS TO ESD &C. 2. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 26. 3. THE CONTRACTOR FOR THIS DIVISION OF WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS OR HER SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTORS RESPONSIBILITY TO PROVIDE HIS OR HER SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 4. THIS ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THIS WORK TO COMPLY WITH THE ESD &C SCHEDULE AND THE PROJECT COMPLETION DATE. 5. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK. ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTORS BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF HIS OR HER WORK. 6. REFER TO RESPONSIBILITY SCHEDULE ON SHEET E02.3 OF THIS SET FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. B. GENERAL REQUIREMENTS 1. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE A COMPLETE ELECTRICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR ESD &C SHALL BE PROVIDED BY THIS CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH THE LANDLORD AND THE ESD &C PROJECT MANAGER, AS REQUIRED. 2. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED AND INSTALLED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK, AND WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE FURNISHED AND INSTALLED AS PART OF CONTRACT. 3. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. 4. ALL WORK IN THIS SECTION SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING, AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. 5. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD CONSTRUCTION PRACTICES. 6. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. 7. THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING AND CHANNELING REQUIRED FOR ANY WORK UNDER THIS DIVISION. CUTTING SHALL HAVE PRIOR APPROVAL BY ESD &C PROJECT MANAGER AND THE LANDLORD. ALL PATCHING SHALL BE BY G.C. AND SHALL MATCH THE SURROUNDING SURFACES. 8. THE ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. C. TEMPORARY LIGHT AND POWER 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL TEMPORARY WIRING AND RELATED GROUND FAULT INTERRUPTION PROTECTION FOR LIGHT AND POWER FOR ALL CONTRACTORS AND IS RESPONSIBLE FOR IT'S REMOVAL 2. THE GENERAL CONTRACTOR SETS UP ALL ELECTRICAL UTILITIES IN THE NAME OF ESD &C. ESD &C PAYS FOR ALL UTILITIES THROUGHOUT CONSTRUCTION. D. CODES 1. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE HANGERS ARE NOT INCLUDED IN THE BID, THEY SHALL BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS AWARDED, CHANGE ORDERS FOR INCREASED COSTS DUE TO CODE ISSUES WILL NOT BE ACCEPTED BY ESD &C, UNLESS ALLOWANCES HAVE PREVIOUSLY BEEN AGREED UPON. E. LICENSES, PERMITS, INSPECTIONS & FEES 1. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO HIS OR HER WORK. 2. FURNISH TO THE ESD &C'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. F. TRADE NAMES, MANUFACTURERS & SHOP DRAWINGS 1. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE SUBJECT TO APPROVAL IN WRITING BY ESD &C'S PROJECT MANAGER THROUGH SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE PRIOR TO INSTALLATIONS. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE REPLACED AT THE CONTRACTOR'S EXPENSE. 2. GENERAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO ESD &C PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR ESD &C PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS. SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND THE SUBCONTRACTOR SHOWING THAT HE HAS REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. G. GUARANTEE 1. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER HIS OR HER CONTRACT AND SHALL MAKE GOOD, REPAIR OR, REPLACE AT HIS OR HER OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE OF THE INSTALLATION BY ESD &C'S PROJECT MANAGER (IN WRITING). EXTENDED WARRANTIES ARE AS SPECIFIED WITH INDIVIDUAL EQUIPMENT. 2. THE EQUIPMENT MANUFACTURER SHALL GUARANTEE AND PROVIDE A 12 MONTH GUARANTEE TO ESD &C FROM THE DATE OF ACCEPTANCE. THE CONTRACTOR SHALL WARRANT" TIjE INSTALLATION OF THIS EQUIPMENT AND WILL BE RESPONSIBLE FOR ANY DAMAGE AND /OR MALFUNCTION CAUSED BY THE INSTALLATION. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM. H. RECORD DRAWINGS 1. THIS CONTRACTOR SHALL MAINTAIN ONE SET OF DRAWINGS ON THE JOB SITE UPDATED WEEKLY TO RECORD ALL DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: a. b. c. LOCATION OF CONCEALED PULLBOXES. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. 2. AT COMPLETION OF THE PROJECT AND BEFORE FINAL APPROVAL, THIS CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. FAILURE TO KEEP THESE RECORDS WILL ALLOW ESD &C TO DIRECT THE GENERAL CONTRACTOR TO PROVIDE THESE RECORDS AT HIS OR HER EXPENSE PRIOR TO FINAL PAYMENT. I. DISCREPANCIES IN DOCUMENTS 1. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEMS. WHERE DRAWINGS, EXISTING:-SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE THE GENERAL CONTRACTOR IN WRITING, PRIOR TO ,SUBMITTAL OF BID. THE GENERAL CONTRACTOR IS RESPONSIBLE TO ADVISE ESD &C'S PROJECT MANAGER, IN WRITING, OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMISSION OF BID. OTHERWISE, ESD &C PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. J. PHASING REQUIREMENTS 1. THIS CONTRACTOR IS TO INCLUDE IN HIS OR HER BID ALL NECESSARY SERVICE REQUIRED TO KEEP THE OPERATING PHASE OF THE STORE'S HVAC, ELECTRICAL, PLUMBING AND SPRINKLER SERVICE IN OPERATION. CONTRACTOR SHALL SCHEDULE IN WRITING WITH ESD &C'S PROJECT MANAGER AND THE LANDLORD ONE WEEK PRIOR TO ANY SHUT DOWN OF THE HVAC, PLUMBING OR FIRE PROTECTION SYSTEMS. K. DEMOLITION 1. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 2. THIS CONTRACTOR SHALL INCLUDE, AND WILL BE HELD RESPONSIBLE FOR, THE REMOVAL OF ALL EXISTING CONDUIT, FIRE ALARM SYSTEM, SWITCH GEAR, PITCH POCKETS AND EQUIPMENT ETC.. UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR SHALL VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, CONDUIT AND SWITCH GEAR PRIOR TO REMOVAL. PITCH POCKETS SHALL BE REMOVED AND THE ROOF PATCHED, AS REQUIRED BY THE LANDLORD. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK SHALL BE REMOVED AND ROOF /WALL /FLOOR PATCHED /REPAIRED TO LIKE NEW CONDITION. EXISTING ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE, ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT SHALL BE REMOVED TO POINT OF ORIGINATION. CONFIRM EXTENT OF DEMOLITION PRIOR TO BID AND INCLUDE IN PROPOSAL. 3. ALL UNUSED COMMUNICATION, DATA, AND LOW VOLTAGE CABLING IS TO BE REMOVED IN ACCORDANCE WITH N.E.C. 725.(3)B AND 760.3(A). L. SLEEVES 1. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR SHALL COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. 2. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND /OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. 3. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS, AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL PIPING, SLEEVES SHALL BE NO. 22 U.S.G. GALVANIZED STEEL MINIMUM. M. HANGERS 1. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, BANDS, C- CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. 2. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS SHALL BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR SHALL INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA. 3. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. 4. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI- ELECTRICALLY SEPARATED. N. FINAL ELECTRICAL INSPECTIONS 1. ASIDE FROM NORMAL INTERIM INSPECTIONS OF WORK IN PLACE, ESD &C MAY HAVE AN INDEPENDENT ELECTRICAL CONTRACTOR INSPECT THE FINISHED ELECTRICAL INSTALLATION UPON COMPLETION FOR COMPLIANCE WITH THE PLANS, SPECIFICATIONS AND CODES. THE INSTALLING CONTRACTOR WILL BE RESPONSIBLE TO BRING ALL ITEMS REPORTED BY THE INDEPENDENT ELECTRICAL CONTRACTOR UP TO PLANS AND SPECIFICATION REQUIREMENTS. O. SCOPE OF WORK 1. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, AND FACILITIES NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: a. A COMPLETE ELECTRICAL DISTRIBUTION SYSTEM INCLUDING THE INSTALLATION OF ESD &C FURNISHED POWER DISTRIBUTION SYSTEM UNIT, SAFETY SWITCHES, DISCONNECT SWITCHES AND MOTOR STARTERS (SOMETIMES FURNISHED AND INSTALLED BY CONTRACTOR), AND LIGHTING. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO INCLUDE IN HIS OR HER BID FOR PROVIDING SERVICE EQUIPMENT NECESSARY FOR TIE -IN TO LANDLORD'S DISTRIBUTION EQUIPMENT OR TO OBTAIN SERVICE FROM LOCAL UTILITY COMPANY. REFER TO ELECTRICAL RESPONSIBILITY SCHEDULE AND ELECTRICAL POWER RISER DIAGRAM FOR ADDITIONAL INFORMATION. b. CONTRACTOR SHALL INCLUDE IN BID ALL NECESSARY MATERIALS REQUIRED TO COMPLETE THE SYSTEM INCLUDING, BUT NOT LIMITED TO, FEEDERS, BRANCH CIRCUITS, JUNCTION BOXES, OUTLET BOXES, WIRING DEVICES, COVERPLATES, CONDUITS, MOTOR STARTERS, DISCONNECTS, ETC. c. METERING AND CURRENT TRANSFORMERS AS REQUIRED BY DRAWINGS, ESD &C, UTILITY COMPANY, AND /OR LANDLORD. d. THE WIRING OF MECHANICAL EQUIPMENT AS OUTLINED ON THE BID SET DRAWINGS AND IN THE SPECIFICATIONS. WORK SHALL INCLUDE WIRING OF ALL STARTERS, DISCONNECTS, AND POWER WIRING OF MECHANICAL EQUIPMENT EXCEPT AS SPECIFICALLY NOTED OTHERWISE. ALL LOW VOLTAGE (24 VOLT) EMS TEMPERATURE CONTROL WIRING SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR UNLESS NOTED SPECIFICALLY ON DRAWING. e. INSTALLATION OF LIGHT FIXTURES AND LAMPS AS SHOWN ON THE DRAWINGS INCLUDING ALL DEVICES, EQUIPMENT, ETC. REQUIRED FOR MOUNTING. f. A COMPLETE CONDUIT SYSTEM FOR TELEPHONE /DATA INCLUDING BRANCH CONDUITS, OUTLET BOXES, PULL WIRES, GROUND CONDUCTORS, COVER PLATES, ETC. OR AS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. g. A COMPLETE EMERGENCY AND EXIT LIGHTING SYSTEM AS SHOWN ON THE DRAWINGS. h. TEMPORARY SERVICE AS INDICATED IN THE SPECIFICATIONS, INCLUDING IT'S REMOVAL. L FINAL CONNECTIONS TO ALL SIGNS, CORNICE LIGHTING, CASE LIGHTING, ETC. AS SHOWN ON DRAWINGS. j. IF INDICATED ON DRAWINGS, INSTALLATION AND WIRING OF SPEAKERS, AMPLIFIERS, CONDUIT AND FINAL CONNECTIONS FOR SOUND SYSTEM AS SHOWN. k. SMOKE /FIRE ALARM WIRING, DEVICES AND CONDUIT, AS SHOWN OR DESCRIBED ON DRAWINGS OR AS NECESSARY TO MEET LANDLORD, STATE, LOCAL, INSURANCE AND FIRE DEPARTMENT REQUIREMENTS. I. INSTALLATION OF CONDUITS STUBBED TO ABOVE CEILING FOR HVAC. ALSO, ANY ADDITIONAL CONDUIT FOR HVAC CONTROL EQUIPMENT WHERE PLENUM RATED CABLES ARE NOT PERMITTED. m. BALANCING LOADS. n. AS- BUILTS, PANEL DESCRIPTION AND CIRCUIT BREAKER SPECIFIC LABELING. 2. WORK NOT INCLUDED THE FOLLOWING ITEMS OF ELECTRICAL CONSTRUCTION ARE NOT INCLUDED IN THIS CONTRACT: a. TELEPHONE INSTRUMENTS AND WIRING UNLESS NOTED OTHERWISE. b. DATA CABLE WIRING UNLESS NOTED OTHERWISE. 3. BEFORE STARTING WORK, THIS CONTRACTOR SHALL EXAMINE THE ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL AND PLUMBING PLANS, SHOP DRAWINGS AND SPECIFICATIONS TO SEQUENCE, COORDINATE, AND INTEGRATE THE VARIOUS ELEMENTS OF THE ELECTRICAL SYSTEM, MATERIALS AND EQUIPMENT WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. P. CLEANING 1. AT THE END OF THE PROJECT, THIS CONTRACTOR SHALL CLEAN ALL EQUIPMENT, INCLUDING LIGHT FIXTURES, TO THE SATISFACTION OF ESD &C. ALL DUST, DIRT, DEBRIS, AND FOREIGN MATTER SHALL BE REMOVED FROM ALL EQUIPMENT. END OF SECTION 26 00 00 SECTION 26 01 26 - MAINTENANCE TESTING OF ELECTRICAL SYSTEMS 1. ALL CONNECTIONS AT PANELS, LIGHTING CONTACTORS AND SWITCHES ARE TO BE MADE, ALL SPLICES COMPLETE, ALL FUSES IN PLACE, AND ALL CIRCUITS CONTINUOUS FROM POINT OF SERVICE CONNECTION TO ITS FINAL DESTINATION, AND ALL COVERS AND PLATES INSTALLED PRIOR TO THE TIME OF FINAL INSPECTION BY ESD &C'S PROJECT MANAGER. 2. UPON COMPLETION OF THE WORK, ALL PARTS OF THE ELECTRICAL INSTALLATION SHALL BE TESTED AND PROVED FREE OF UNWANTED GROUNDS AND OTHER DEFECTS. 3. ALL OVERLOAD DEVICES, INCLUDING EQUIPMENT FURNISHED UNDER OTHER CONTRACTS, SHALL BE SET AND ADJUSTED TO SUIT THE LOAD CONDITIONS. 4. TEST AND MAKE CORRECTIONS /ADJUSTMENTS FOR PHASE BALANCING. 5. THIS CONTRACTOR IS TO BALANCE THE VOLTAGE LEAVING THE STEP -DOWN TRANSFORMER TO PROVIDE A SECONDARY VOLTAGE OF 120 MINIMUM TO 125 VOLTS MAXIMUM BY ADJUSTING THE TRANSFORMER TAPS ONCE ALL THE FINAL CONNECTIONS HAVE BEEN MADE TO THE LOW VOLTAGE PANELBOARD. INCLUDE FINAL BALANCE REPORT WITH AS -BUILT DRAWINGS. END OF SECTION 26 01 26 SECTION 26 05 19 - ELECTRICAL POWER CONDUCTORS AND CABLES 1. CONDUCTORS FOR FEEDERS AND BRANCH CIRCUITS SHALL BE COPPER AND THE AWG SIZE AND TYPE AS SHOWN ON DRAWINGS. MINIMUM WIRE SIZE SHALL BE #12 AND THE CONDUCTORS SHALL BE 600 VOLT INSULATION TYPE THW, THWN OR THHN. 2. MINIMUM WIRE SIZE - 20 AMP BRANCH CIRCUIT SHALL BE AWG LISTED SIZE PER DISTANCE SHOWN BELOW. DISTANCE SHALL BE MEASURED FROM THE PANELBOARD CIRCUIT BREAKER TO THE FARTHEST OUTLET. a. #12 LESS THAN 100 FEET b. 110 BETWEEN 100 - 150 FEET c. 18 BETWEEN 150 - 250 FEET d. #6 OVER 250 FEET 3. ON ALL 20 AMP BRANCH CIRCUITS, CONDUCTORS LARGER THAN #10 AWG SHALL BE REDUCED TO #10 AWG WITHIN 10 FEET OF PANELBOARD AND DEVICE IN JUNCTION BOXES ON RATED TERMINAL STRIPS. 4. CONDUCTORS MAY BE STRANDED FOR SIZES #10 AWG AND LARGER. .CONDUCTORS SIZE #12 SHALL BE SOLID. 5. ALUMINUM CONDUCTORS ARE NOT PERMITTED, EXCEPT AT SERVICE ENTRANCE, WHERE REQUIRED BY LANDLORD. CONDUCTOR CONNECTION SHALL BE PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR SHALL OBTAIN WRITTEN PERMISSION FROM GENERAL CONTRACTOR AND ESD &C'S PROJECT MANAGER WHEN USED. 6. ALL WIRING SHALL BE IN CONDUIT, UNLESS SPECIFICALLY NOTED OTHERWISE (IE. LOW VOLTAGE PLENUM RATED WIRE). 7. THE USE OF ROMEX OR BX CABLE IS NOT PERMITTED. 8. WIRE CONNECTORS SHALL BE EQUAL TO "SCOTCH LOCK" FOR #8 AWG WIRE AND SMALLER AND EQUAL TO T & B "LOCKTIGHT" FOR #6 AWG AND LARGER. 9. NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. END OF SECTION 26 05 19 SECTION 26 05 23 - CONTROL VOLTAGE ELECTRICAL POWER CABLES 1. FURNISH AND INSTALL A SYSTEM OF CONDUIT RACEWAYS, OUTLET BOXES AND PULL WIRES AS SHOWN ON THE DRAWINGS UNLESS OTHERWISE NOTED ON PLANS. TELEPHONE SWITCHING APPARATUS, CONDUCTORS, INSTRUMENTS, MISCELLANEOUS EQUIPMENT AND APPURTENANCES ARE NOT PART OF THIS CONTRACT AND WILL BE PROVIDED AND INSTALLED BY ESD &C. 2. OUTLET BOXES TO BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. 3. CONDUIT RUNS FROM IFS ENCLOSURE OR MANAGER'S OFFICE FOR TELEPHONE AND DATA LINES TO CASHWRAPS ARE TO BE CONTINUOUS WITH NO JUNCTION BOXES EXCEPT AS NOTED OTHERWISE ON DRAWINGS. 4. ALL PULL WIRES ARE TO BE LABELED FOR PURPOSE DESIGNATED. 5. NO OTHER CIRCUITS ARE TO BE RUN IN SAME CONDUIT FEEDING ISOLATED GROUND RECEPTACLES. 6. ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL DRAWINGS FOR ADDITIONAL ELECTRICAL WORK TO BE INCLUDED IN HIS OR HER BID. 7. ELECTRICAL CONTRACTOR SHALL DO ALL POWER WIRINGS, LINE VOLTAGE WIRINGS, AND LINE VOLTAGE CONTROL WIRING INDICATED UNDER THE HEATING, VENTILATION AND AIR CONDITIONING, PLUMBING AND FIRE PROTECTION SPECIFICATIONS AND DRAWINGS. THIS CONTRACTOR SHALL ALSO DO ALL INTERCONNECTING LINE VOLTAGE WIRINGS BETWEEN RELAYS AND SWITCHES AS REQUIRED. 8. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING CONDUIT FOR HVAC CONTROL WIRING WHERE REQUIRED BY CODE OR SHOWN ON PRINTS TO BE IN CONDUIT. REFER TO PLANS FOR REQUIREMENTS AND SIZE. ELECTRICAL SPECIFICATIONS 9. FIRE AND /OR SMOKE DAMPERS SHALL BE WIRED BY ELECTRICAL CONTRACTOR. COORDINATE WITH HVAC CONTRACTOR FOR POWER REQUIREMENTS. 10. REFER TO MECHANICAL DRAWINGS FOR AVAILABLE SCHEMATIC WIRING DIAGRAMS OF EQUIPMENT. END OF SECTION 26 05 23 SECTION 26 05 26 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS 1. FURNISH AND INSTALL COMPLETE WIRED GROUNDING CONDUCTOR SYSTEM, #12 AWG MINIMUM, SIZED AND INSTALLED IN ACCORDANCE WITH THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, THE LANDLORD'S TENANT CRITERIA, AS NOTED IN THE SPECIFICATIONS, AND AS INDICATED ON THE DRAWINGS. 2. ALL CONDUITS, INCLUDING FLEXIBLE METAL CONDUIT, SHALL BE GROUNDED WITH A GREEN GROUNDING CONDUCTOR. 3. GROUNDING CONNECTIONS MADE TO THE WATER PIPING SYSTEM SHALL BE COORDINATED WITH THE PLUMBING CONTRACTOR AND A BONDING JUMPER INSTALLED AROUND WATER METER PER CODES AND AS INDICATED ON DRAWINGS. 4. ALL DEVICES SHALL BE BONDED TO THE CONDUIT SYSTEM. USE A BONDING JUMPER BETWEEN THE OUTLET BOX AND THE DEVICE GROUNDING TERMINAL. METAL -TO -METAL CONTACT BETWEEN THE DEVICE YOKE AND THE OUTLET BOX IS NOT ACCEPTABLE AS A BOND FOR EITHER SURFACE MOUNTED BOXES OR FLUSH TYPE BOXES. ALL JUNCTION BOXES, OUTLET BOXES, AND PULL BOXES SHALL BE BONDED TO THE CONDUIT SYSTEM. 5. RUN A SEPARATE ISOLATED GROUNDING CONDUCTOR, #12 AWG MINIMUM, IN EACH CONDUIT FEEDING THE CASHWRAP, THE SENSORMATIC AND OTHER COMPUTERIZED EQUIPMENT AS SHOWN ON DRAWINGS. 6. ALL ENCLOSURES AND NON- CURRENT CARRYING METAL PARTS ARE TO BE GROUNDED. CONDUIT SYSTEM IS TO BE ELECTRICALLY CONTINUOUS. ALL LOCKNUTS SHALL CUT THROUGH ENAMELED OR PAINTED SURFACES ON ENCLOSURES. WHERE ENCLOSURES AND NON- CURRENT CARRYING METAL PARTS ARE ISOLATED FROM THE CONDUIT SYSTEM, USE BONDING JUMPERS WITH APPROVED CLAMPS. ALL GROUND CLAMPS SHALL BE "PENN- UNION" OR EQUAL, SIMILAR TO "GPL" TYPE. END OF SECTION 26 05 26 SECTION 26 05 33 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL CONDUITS SERVING ALL EQUIPMENT, INCLUDING BUT NOT LIMITED TO, LIGHTING, RECEPTACLES, HEATING, AIR CONDITIONING, PLUMBING EQUIPMENT, TELEPHONE, DATA, SPEAKERS, SECURITY, PAGER, TRAFFIC COUNTING SYSTEM AND ELECTRICAL EQUIPMENT. 2. ALL CONDUITS SHALL BE GALVANIZED IMC OR EMT UNLESS OTHERWISE SPECIFIED IN SPECIFICATIONS OR ON DRAWINGS. ALL CONDUIT IS TO BE UL LABELED. EMT CONNECTORS SHALL BE STEEL COMPRESSION OR SET SCREW TYPE. CONDUIT UNDER SLAB ON GRADE SHALL BE RIGID STEEL, OR SCHEDULE 40 PVC WITH RIGID STEEL ELLS WHERE PERMITTED BY LANDLORD OR CODE. 3. MINIMUM SIZE OF CONDUIT SHALL BE: a. MAIN FEEDER CONDUIT TO 2" OR LARGER FOR ALL APPLICATIONS. b. 1/2" MINIMUM FOR ALL LOCATIONS (IF ACCEPTABLE BY THE LANDLORD AND LOCAL CODE OFFICIALS), UNLESS NOTED OTHERWISE IN PLANS, SPECIFICATIONS, OR DRAWINGS. c. IF HVAC CONTROL WIRING IS REQUIRED TO BE RUN IN CONDUIT, IT SHALL BE A MINIMUM OF 3/4 ", UNLESS NOTED OTHERWISE ON DRAWINGS. d. ALL IN /UNDER FLOOR CONDUIT SHALL BE OF MINIMUM 3/4" SIZE. e. ALL FIRE ALARM CONDUIT SHALL BE OF MINIMUM 3/4" SIZE. 4. SUPPORT ALL CONDUIT, INCLUDING SEISMIC AND SWAY BRACING, IN ACCORDANCE WITH THE NEC AND LOCAL CODES. 5. GENERALLY, ALL CONDUIT SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY ESD &C'S PROJECT MANAGER. PAINTING OF CONDUITS, NOTED ON DRAWINGS OR SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR. 6. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE a. FLEXIBLE METAL CONDUIT OR MC TYPE CABLE SHALL BE USED FOR THE FOLLOWING APPLICATIONS ONLY: I. FINAL CONNECTIONS TO MOTORS. 11. FINAL CONNECTIONS INTO AND OUT OF THE TRANSFORMER. 111. FINAL CONNECTIONS TO VIBRATING EQUIPMENT. IV. INTER - CONNECTIONS BETWEEN ALL RECESSED LIGHT FIXTURES AND JUNCTION BOXES. V. FINAL CONNECTIONS WHERE RIGID CONDUIT I5 NOT PRACTICAL. VI. IN WALLS (FOR LIGHT SWITCHES AND 120 VOLT POWER RECEPTACLES AND HVAC CONTROL EQUIPMENT). b. FLEXIBLE METAL CONDUIT SHALL BE THE SAME SIZE AS THE IMC OR EMT CONDUIT TO WHICH IT 15 CONNECTED. BOTH THE FLEXIBLE METAL CONDUIT AND IT'S FITTINGS ARE TO BE LISTED FOR GROUNDING. A GREEN GROUNDING CONDUCTOR SHALL BE INSTALLED. ALL CONNECTORS ARE TO BE OF A NEMA APPROVED TYPE. c. LENGTH OF FLEXIBLE METAL CONDUIT IS NOT TO EXCEED 6' -O ". d. THE USE OF ROMEX OR BX CABLE IS NOT PERMITTED. 0. CONNECTION TO ANY OUTDOOR EQUIPMENT SHALL BE MADE WITH LIQUIDTIGHT FLEXIBLE METAL CONDUIT. 7. PROVIDE PULL -WIRE IN ALL EMPTY CONDUITS EXCEPT AS NOTED OTHERWISE ON DRAWINGS. 8. HOME RUNS AND MAIN CONDUIT RUNS ARE TO BE HELD TIGHT TO STRUCTURE ABOVE OR AS REQUIRED TO ALLOW PROPER SERVICE ACCESS AND OTHER TRADES WORK. CONDUIT SHALL BE TRAPEZED TO ALLOW 3 FEET MINIMUM CLEARANCE ABOVE CEILING. 9. ALL CONDUITS SHALL BE SIZED PER NEC AND LOCAL CODES. 10. ALL SENSORMATIC WIRING SHALL BE PLACED IN EMT, IMC, OR RMC CONDUIT. PVC IS NOT ALLOWED. 11. ALL OUTLET BOXES SHALL BE GALVANIZED PRESSED STEEL OF THE STANDARD KNOCKOUT TYPE. NO ROUND OUTLET BOXES SHALL BE PERMITTED UNLESS INDICATED AND FOR LIGHTING THAT REQUIRE SUCH CONFIGURATION. CONCEALED BOXES SHALL NOT BE LESS THAN 4" SQUARE AND 1 -1/2" DEEP, WITH PLASTER RINGS. 12. ALL KNOCKOUT BOXES, UPON WHICH LIGHTING FIXTURES ARE TO BE INSTALLED, SHALL BE EQUIPPED WITH 3/8" FIXTURE STUDS. 13. EXTERIOR BOXES SHALL BE CAST RUST - RESISTING METAL WITH GASKETED COVERS. 14. INSTALL BOXES RIGIDLY FROM BUILDING STRUCTURE AND SUPPORT INDEPENDENTLY OF THE CONDUIT SYSTEM. ALSO PROVIDE SUITABLE BOX EXTENSIONS TO EXTEND BOXES TO FINISHED FACES OF FLOORS, CEILINGS, WALLS ETC. ALL OUTLET BOXES TO BE PROVIDED WITH CADDY "QUICK -MOUNT BOX SUPPORT" TO MINIMIZE THE DEFLECTION THAT OCCURS WHEN PLUGGING /UNPLUGGING INTO THESE DEVICES. 15. UNLESS OTHERWISE NOTED ON DRAWINGS OR OTHERWISE REQUIRED BY THE NATIONAL ELECTRICAL CODE, HANDICAP CODES OR LOCAL CODES, OUTLET HEIGHTS SHALL BE AS FOLLOWS: a. SWITCH HEIGHT 48" FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. b. - CONVENIENCE OUTLETS: I. SALES AREAS: MOUNTED ON THE WALL 15" AFF UNLESS INDICATED OR HORIZONTALLY MOUNTED IN BASEBOARD BENEATH CABINETS, AS SHOWN ON DRAWINGS, OR AS REQUIRED BY LOCAL CODES. SEE DRAWINGS. 11. NON- SALES AREA: 15" FROM FINISHED FLOOR TO CENTERLINE OF OUTLET. c. TELEPHONE OUTLETS SHALL BE LOCATED AS NOTED ON DRAWINGS. 16. THE PLANS INDICATE ONLY SCHEMATIC ROUTINGS FOR CONDUIT RUNS. THIS CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL BOXES WHERE REQUIRED BY FIELD CONDITIONS OR BY CODE. 17. BOXES AND COVERS SHALL BE GALVANIZED STEEL OF CODE GAUGE SIZE 18. ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHOULD BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. END OF SECTION 26 05 33 SECTION 26 05 53 ID ENTIFICA • N FOR ELECTRIGAL SYSTEMS 1. ALL WIRING SHALL BE COLOR -CODED AS FOLLOWS: 120/208 VOLT SYSTEM NEUTRAL - WHITE PHASE A OR L1 - BLACK PHASE B OR L2 - RED PHASE C OR L3 - BLUE GROUND - GREEN ISOLATED GROUND - GREEN WITH YELLOW TRACER 277/480 VOLT SYSTEM NEUTRAL - GRAY PHASE A OR L1 - BROWN PHASE B OR L2 - ORANGE PHASE C OR L3 - YELLOW GROUND - GREEN 2. JUNCTION AND PULL BOXES SHALL BE LABELED WITH CIRCUIT NUMBER IDENTIFICATION AND SYSTEM TYPE ON COVER. END OF SECTION 26 05 53 SECTION 26 09 23 - LIGHTING CONTROL EQUIPMENT 1. LIGHTING CONTROL PANEL WILL BE PROVIDED BY ESD &C THROUGH CONTROL MANUFACTURER, MOUNTED IN IFS PANEL WITH CONDUIT, INSTALLED BY THE ELECTRICAL CONTRACTOR. THE CONTROL PANEL SHALL BE PROGRAMMED AND COMPLETE WHEN SHIPPED TO THE JOB SITE THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE TO PULL ALL WIRES AS DETAILED ON THESE DRAWINGS AND CIRCUITED EXACTLY AS DIAGRAMMED ON THE ELECTRICAL PLAN DRAWINGS. NO VARIATIONS TO THE CIRCUITING ARE ALLOWED WITHOUT PRIOR WRITTEN APPROVAL BY ESD &C'S PROJECT MANAGER. END OF SECTION 26 09 23 . SECTION 26 22 13 - DRY TYPE TRANSFORMERS 1. TRANSFORMERS ARE GENERALLY INCLUDED IN THE 'IFS - SWITCHGEAR. IF NOT, TRANSFORMER SHALL BE PAD MOUNTED OR SHALL BE SECURELY MOUNTED FROM THE BUILDING STRUCTURE, REINFORCED WALLS OR AS NOTED ON DRAWINGS. USE ADDITIONAL VIBRATION ISOLATORS AT POINTS OF MOUNTING TO CUT VIBRATION NOISES. USE FLEXIBLE METALLIC CONDUIT WITH GROUNDING BUSHING FOR PRIMARY AND SECONDARY CONNECTIONS TO TRANSFORMER. TRANSFORMERS SHALL BE LOCATED, SET, MOUNTED AND CONNECTED IN SUCH A MANNER AS TO KEEP NOISE LEVELS WITHIN THE SURROUNDING AMBIENT NOISE LEVELS AND MAINTAIN ALL CODE REQUIRED CLEARANCES. 2. TRANSFORMER SHALL BE QUIET TYPE CONSTRUCTION AND HAVE SIX (6) 2 -1/2% TAPS, TWO (2) TAPS ABOVE AND FOUR (4) TAPS BELOW NORMAL PRIMARY RATING. END OF SECTION 26 22 13 SECTION 26 24 16 - PANELBOARDS 1. ALL PANELBOARDS SHALL BE FACTORY ASSEMBLED OF THE BOLTED CIRCUIT BREAKER TYPE WITH SOLID COPPER BUSSING, FULL SIZED COPPER NEUTRAL, 100% GROUND BUSHING, AND OVERALL HINGED /LOCKABLE DOOR. ALL CIRCUIT BREAKERS SHALL BE OF THE QUICK -MAKE AND QUICK -BREAK DESIGN, THERMAL - MAGNETIC TYPE, TRIP FREE AND TRIP - INDICATING. ALL PANELS SHALL BE DEAD FRONT AND FLUSH OR SURFACE MOUNTED AS SHOWN. 2. CONTRACTOR SHALL FURNISH AND INSTALL A TYPEWRITTEN DIRECTORY CARD OF THE CIRCUITS AND PLACE IN PANEL DOOR. THE DIRECTORY SHALL IDENTIFY THE SPECIFIC ROOM LOCATION FOR EACH CIRCUIT. 3. ALL PANELBOARDS PHASE AMPERAGE SHALL BE BALANCED TO WITHIN 7 PERCENT MAX. TO MIN. REARRANGE NON- LIGHTING BRANCH CIRCUITS AS REQUIRED AND NOTE CHANGES ON RECORD DRAWINGS. LIGHTING PANEL CIRCUIT BREAKERS SHALL BE INSTALLED AND WIRED EXACTLY AS SHOWN ON DRAWINGS. 4. IF LOOSE PANELBOARDS ARE USED, PANELBOARDS SHALL BE MOUNTED ON MINIMUM 3/4" A/D PLYWOOD AND PAINTED IN A COLOR TO MATCH THE SURROUNDING WALLS OR A COLOR AS REQUIRED BY LOCAL CODE. PLYWOOD SHALL EXTEND 1 FOOT MINIMUM BEYOND EDGE OF EQUIPMENT. 5. PANELBOARDS SHALL HAVE A MINIMUM SHORT CIRCUIT CURRENT RATING AND LUG CONNECTIONS AS FOLLOWS: 120/208 VOLT PANELBOARDS: 10,000 A.I.C. 277/480 VOLT PANELBOARDS: 14,000 A.I.C. VERIFY ACTUAL A.I.C. SHORT CIRCUIT CURRENT REQUIREMENTS WITH THE LANDLORD OR UTILITY COMPANY AND VERIFY SWITCHGEAR COMPLIANCE PRIOR TO INSTALLING EQUIPMENT. ALL LUG CONNECTIONS TO BE 75'C RATED. 6. IFS ENCLOSURE FURNISHED BY ESD &C AND INSTALLED BY ELECTRICAL CONTRACTOR IS HEREIN DESCRIBED: a. UNIT WILL BE SHIPPED TO THE PROJECT IN MULTIPLE SECTIONS AND THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR OFF- LOADING OF EQUIPMENT, INSPECTION OF EQUIPMENT FOR DAMAGES, VERIFICATION OF EQUIPMENT RECEIVED, ENSURING THAT THE EQUIPMENT RECEIVED IS COMPLETE AND MEETS THE SCHEDULED PANELS FOR THE PROJECT, MOVING AND MOUNTING OF SECTIONS AS WELL AS REASSEMBLING OF SAME INTO ONE COMPLETE UNIT PER MANUFACTURER'S REQUIREMENTS. b. ELECTRICAL CONTRACTOR IS TO CONNECT ALL PROVIDED INTERCONNECTING CABLES BETWEEN SECTIONS AND TORQUE CONNECTIONS PER MANUFACTURER'S REQUIREMENTS. CONTRACTOR IS TO ANCHOR PANEL SYSTEM IN ACCORDANCE WITH MANUFACTURERS SPECIFICATIONS AND LOCAL CODES IN SEISMIC ZONES. c. ELECTRICAL CONTRACTOR IS TO CONNECT LIGHTING BRANCH CIRCUITS TO APPROPRIATE LOAD TERMINALS PROVIDED WITHIN IFS ENCLOSURE PER LIGHTING ZONES INDICATED IN THE PANEL SCHEDULE (I.E: ZONE A, B, C, OR D). LINE SIDE WIRING AND LIGHTING CONTROL WIRING WILL BE PREWIRED BY MANUFACTURER AT FACTORY. COORDINATE EXACT TERMINAL NUMBER FOR EACH CIRCUIT CONNECTION WITH MANUFACTURER'S DRAWINGS. d. ALL LIGHTING, RECEPTACLE AND MISCELLANEOUS BRANCH CIRCUITS NOT SPECIFIED AS BEING CONTROLLED, ARE TO BE WIRED DIRECTLY TO THE CORRESPONDING BRANCH BREAKER IN THE DESIGNATED PANEL e. ALL CONNECTIONS WITHIN THE TELEPHONE /DATA SECTION AND HVAC CONTROL SECTION OF THE IFS ENCLOSURE ARE TO BE PERFORMED BY OTHERS. f. ELECTRICAL CONTRACTOR WILL ONLY BE RESPONSIBLE FOR INSTALLATION OF THE CONDUIT SYSTEM INTO THE LOW VOLTAGE SECTION OF THE IFS PANEL. END OF SECTION 26 24 16 SECTION 26 27 26 - WIRING DEVICES 1. THIS CONTRACTOR SHALL FURNISH AND INSTALL SWITCHES AND RECEPTACLES, UNLESS NOTED OTHERWISE, AS NECESSARY FOR A COMPLETE INSTALLATION. COLOR OF DEVICES AND PLATES SHALL BE SELECTED BY ESD &C. THE DEVICES SHALL BE OF THE TYPES AND RATINGS LISTED, OR EQUALS BY ARROW -HART, HUBBELL OR PASS & SEYMOUR. WEATHERPROOF GFI RECEPTACLES SHALL BE INSTALLED WHERE SHOWN ON DRAWINGS OR AS REQUIRED BY CODE. SINGLE POLE TOGGLE SWITCHES: 20 AMP,120 -277V: PASS & SEYMOUR "PS2OAC1 -W" THREE WAY SWITCHES: 20 AMP, 120 -277V: PASS & SEYMOUR "PS2OAC3 -W" DUPLEX RECEPTACLES: 20 AMP, 125V: PASS & SEYMOUR "BR2OW" ISOLATED GROUND RECEPTACLES: 20 AMP, 125V: PASS & SEYMOUR "IG6300W" GROUND FAULT CIRCUIT INTERRUPTING RECEPTACLES: 20 AMP, 125V: PASS & SEYMOUR "2094 -W" 2. ALL DEVICE COVERPLATES SHALL BE PASS AND SEYMOUR SERIES "TP" OR EQUAL. END OF SECTION 26 27 26 REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC 4i MAY - b 2008 Icy Off Tukwila BUILDING DIVISION SECTION 26 28 16 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS 1. SAFETY AND DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, QUICK -MAKE, QUICK -BREAK FUSED OR NON- FUSIBLE WITH RATINGS AND SIZES AS NOTED ON PLANS AND REQUIRED BY CODES. 2. SWITCHES SHALL BE WEATHERPROOF IN OUTDOOR LOCATIONS OR AS REQUIRED BY LOCAL CODES. 3. AT SERVICE ENTRANCE, DISCONNECT SHALL BEAR THE MANUFACTURER'S LABEL INDICATING THE EQUIPMENT IS UL RATED FOR APPLICATION IN ACCORDANCE WITH ALL CODES. 4. CUTLER HAMMER OR EQUAL MANUAL MOTOR STARTERS, LESS OVERLOAD PROTECTION HEATERS, ARE TO BE USED AS A DISCONNECTING MEANS ONLY WHERE INDICATED ON DRAWINGS FOR MOTORS ABOVE 1 1/2 HP AT 120 VOLTS AND 2 HP AT 240 VOLTS THAT DO NOT REQUIRE AUXILIARY CONTROL MOTORS THAT ARE BELOW THE 1 1/2 HP AT 120 VOLTS, 2 HP AT 240 VOLTS, WATER HEATER AND ROLLING GRILLE ARE TO BE PROVIDED WITH HUBBELL "HEIL -1221, OR 1222" AC SWITCH. 5. MAGNETIC MOTOR STARTERS SHALL BE PROVIDED WITH RESET TYPE OVERLOADS THAT CLOSELY MATCH MOTOR NAMEPLATE RATING AND SHALL BE ELECTRICALLY HELD (MINIMUM SIZE #1 IN A NEMA 1 ENCLOSURE) AND BE USED FOR ALL SINGLE PHASE AND THREE PHASE MOTORS RATED ABOVE 1/2 HP THAT REQUIRE AUXILIARY CONTROL. PROVIDE CONTROL DEVICES (AUXILIARY CONTACTS, TRANSFORMERS, H -O -A, ETC.) IN STARTERS AS REQUIRED FOR INTERLOCKS. COORDINATE ALL CONTROL DEVICES WITH MECHANICAL CONTRACTOR. COMBINATION STARTER /DISCONNECT SWITCHES SHALL CONTAIN FUSIBLE SWITCHES AND ONLY USED WHERE INDICATED ON DRAWINGS. END OF SECTION 26 28 16 SECTION 26 51 00 - INTERIOR LIGHTING REVISIONS No changes shall b me ade to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review tees. 1 1. THIS CONTRACTOR SHALL INSTALL ALL LIGHTING FIXTURES AND LAMPS AS SHOWN ON THE FIXTURE SCHEDULE. LIGHTING FIXTURES AND LAMPS ARE SUPPLIED BY ESD &C, UNLESS NOTED OTHERWISE. CONTRACTOR IS TO REPLACE ALL NON - WORKING LAMPS PRIOR TO MERCHANDISE DATE AND IS TO INCLUDE COST IN BID. 2. ALL RECESSED INCANDESCENT FIXTURES SHALL BE PROVIDED WITH APPLICABLE THERMAL PROTECTION. 3. WHERE FLUORESCENT FIXTURES ARE SPECIFIED, THEY SHALL BE PROVIDED WITH HIGH POWER FACTOR RAPID START BALLASTS, U.L. LISTED, C.B.M. CERTIFIED, AND E.T.L. APPROVED WITH EFFICIENCY FACTORS IN ACCORDANCE WITH THE ENERGY POLICY ACT OF 1992" AND ITS AMENDMENTS AS A MINIMUM. 4. THIS CONTRACTOR SHALL FURNISH ADDITIONAL AUXILIARY SUPPORT STEEL HANGER WIRES ADEQUATELY SIZED TO SUPPORT THE WEIGHT OF THE FIXTURE FASTENED TO THE BUILDING STRUCTURE (MINIMUM TWO PER FIXTURE) FOR ALL FIXTURES IN LAY -IN CEILINGS AND OTHER FIXTURES AS REQUIRED BY THE LANDLORD AND LOCAL CODE OFFICIALS. 5. FURNISH AND INSTALL APPLICABLE FIRE RATED DRYWALL BOXES OVER RECESSED FIXTURES IN FIRE RATED CEILINGS AS REQUIRED BY CODES. FIELD COORDINATE AS REQUIRED TO AVOID CONFLICTS. END OF SECTION 26 51 00 A/C AC A.F.F. AHU AIC AMP., A C. C.B. CCTV CIRC. CEIL. COL. COND CONT. CU. DF DIA. DISC. DISTR DWG E E.F. ELEC. E.W.C. EXIST. EXO EXT. LOC. F.A. FIXT. FLA ABBREVIATIONS - ELECTRICAL AIR CONDITIONER ALTERNATING CURRENT ABOVE FINISH FLOOR AIR HANDLING UNIT AMPERE INTERRUPTING CAPACITY AMPERE CONDUIT CIRCUIT BREAKER CLOSED CIRCUIT TELEVISION CIRCUIT CEILING COLUMN CONDUIT CONTINUED COPPER DRINKING FOUNTAIN DIAMETER DISCONNECT DISTRIBUTION DRAWING EXISTING TO REMAIN EXHAUST FAN ELECTRICAL ELECTRIC WATER COOLER EXISTING EXTERNALLY OPERATED EXTERIOR LOCATION FIRE ALARM FIXTURE FULL LOAD AMPS G GROUND GFI GROUND FAULT INTERRUPTER H.P. HORSE POWER H.V. HIGH VOLTAGE HZ HERTZ IP IFS I.G. INTERCOM PHONE INTEGRATED FACILITY SYSTEM ISOLATED GROUND N.F. J -BOX KVA LCL LTG L..V. MAX MCA MCC MFR. M.H. M.O.C.P. MTD. Par review approval is subject to errors and amiss!, JUNCTION BOX Apprava' Of COflStruCtIOi document does no ^I tho the violation of any adopted code or rdinance. R c of approve i ��^ d COP a ns is r'iOki owied LONG CONTINUOUS LOCAI LIGHTING "y LOW VOLTAGE MAXIMUM MINIMUM CIRCUIT AMPACITY MOTOR CONTROL CENTER MANUFACTURER MOUNTING HEIGHT MAXIMUM OVER CURRENT PROTECTION MOUNTED City of Tukwila BUILDING' DIVISION N.C. NORMALLY CLOSED NON -FUSED N.I.C. NOT IN CONTRACT N.O. NORMALLY OPEN O.C. ON CENTER 0.L. OVERLOAD P P.A. P.E. PNL PWR. RELOC RM R.T. RTU KILOVOLT -AMPS POLE PUBLIC ADDRESS PHOTOELECTRIC PANEL POWER RELOCATED EXISTING ROOM RAIN TIGHT ROOF TOP UNIT SW. SWITCH SW'BD SWITCHBOARD T.C. TEL TYP V W.P. TIME CLOCK TELEPHONE TYPICAL VOLT SEPARATE PERMIT REQUIRED FOR: Mechanical ❑ Iectrical a Iumbin LWGas Piping City of Tukwila BUILDING DIVISION WEATHERPROOF RECEIVED CITY OF TUKVVILA APR 2 9 2008 PERMIT' CENTER le'14?),(a N.T.S. OODE011AOSPEC SHREMSHOCK 6130 S. WESTERVIL 614- 545 => INEERING, INC. ROAD EXPIRES (� - ((o ^ (0 o 0 wEa Y = = w nz z� L w (D � 31w ° r W z 1N., - =- o r W <L.F- ° (Zo W 0 Z ,=O 0 • ° W °n. �(.0 W W OU 2 X 4 a. WUO. :=1 V 0 a F. W r W W -W-s W ::u &v)z▪ °m¢ 3 :aa=te a▪ o�c>F N 0 � � W a0 Vl - ,O(_/1 tan 0-u= O ���O,,V,w W¢ w f- f�oz °Z¢c.i Fvl��oU cS - - as °Z� o�w�= a = =aZ= h Wm r h a- c? W !!!!:; oW 2 i!!:L=i Y M a: N1- m K ¢ 0 > o 0 V 1 K O O! w :'-g-w:(c-:;L::'-] a 3O z4 �'"'-3 >- cr,, W J c!! V) X O 0 W >- o -` 0 0 Q: W n: - U W T V0 00o W 0- =20c W X = 2=W 0 . F=- OS ¢Off.UJ dQ n.r O aa= w a raa a u, 0 0 rx -? W vl N O CO (!.�� u7 CT) 1- O CO CO CL 00 REVISIONS: REQUIRED BY: A • INDICATES NO REVISION TO THIS SHEET DATE ISSUED: 04/18/2008 DESIGNED BY: EDS DRAWN BY: AOH CHECKED BY: RAP ELECTRICAL SPECIFICATIONS DRAWING NUMBER: EQ EQ I'1 1p B -26 8 -22 ELECTRICAL CONTRACTOR SHALL MOUNT RECEPTACLE ON TOP LEDGE OF PLANT SHELF. ELECTRICAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS WITH ARCHITECT PRIOR TO ROUGH -IN (TYPICAL). DENIM ROOM I 1l1 NON -SALES AREA IFS -1 1'1 RESTROOM ALCOVE WOMEN'S TOILET ROOM TO LIGHTING 8 -19 MEN'S TOILET ROOM 1) mm 1. B -12 B -8/10 TO LIGHTING B -11 L GFI MANAGER'S OFFICE 8 -35 T B -37 8 -15 IFS -2 B -18 B -4 TV RECEPT. BREAK AREA PANELS A & B Ip TO TELCO SECTION OF IFS SWITCHGEAR. STUBBED -UP CONDUITS, SEE CASHWRAP DETAIL 4 REGISTER STRAIGHT CASHWRAP. FOR MORE INFORMATION AND DIMENSIONS, REFER TO ARCHITECTURAL SHEETS AND DETAIL ROOM THREE B -2 F.R.9. H.C.F.R.1. Jam RTU -1 1�1 B -30 WOMEN'S ROOM TWO iDe B -31 8 -36 TO TELCO SECTION OF IFS SWITCHGEAR. F.R.8. FITTING ROOM ALCOVE F.R.5. F.R.4. B -28 F.R.3. F.R.B.• F.R.2. • • F.R.1. a E04.1 B -20 STUBBED -UP CONDUITS, SEE CASHWRAP DETAIL 2 REGISTER STRAIGHT CASHWRAP. FOR MORE INFORMATION AND DIMENSIONS, REFER TO ARCHITECTURAL SHEETS AND DETAIL MEN'S ROOM TWO 1�1 I'1 B -24 WOMEN'S ROOM ONE 111 • • • • MEN'S ROOM ONE I'1 (�1 E04.2 16Log)-ii NOTE: REFER TO SHEETS F01.1, F01.2, AND F01.3 FOR FIRE ALARM REQUIREMENTS. OTE: REFER TO SHEET E02.2 FOR POWER CODED NOTES. VERIFY ALL FIELD CONDITIONS PRIOR TO BID O O O REVi wEO FOR ,000E COMPLIANCE t AI _ 0 2000 City Of Tukwila 111)jG DIVISION KEY PLAN SEE SHEET E02.2 ELECTRICAL POWER PLAN 1/4" = 1' -0" A SHREMSHOCK 6130 S. WESTERVI 614 -545 G1NEERING, INC. AD O 0 W Lao w g=z W N34� = = :E.J1 ar J W = O W r Vx,w3w �w n=om = .. • W h Q z O W Wm Z O 430 °0 O 2 0 w mMo-J a w 0 w OV a a 0 w 0 d' O _ L.,,-6. 0 r , Q 0 a II a= Woo U O'0 W (Do w4 °dOW C Z= N 6 N Z 0 0 U 3 0 00= a 0 u 0 = O �arno w S Z W 7 n_ 0 r O = 4 0 c F a Z 2 =ma as W 0 0 Z Q O 0 w a01-o0- 0000581 INFORMATION: N 0 DO CD O 00 CO a. O O 4 W 1- Z W 0 cn O 1- W Z W PC WM�3 M CL 1 ° Lv ' J W X V^ + W I-- o W<N< Q_ 11I 1 O w cn co GO 0) W I— d. Z C9 Ocnc, chow REVISIONS: REQUIRED DY: DATE RECEiVED CITY OF TUKWILA APR 2 9 2008 PERMIT CENTER • INDICATES NO REVISION TO THIS SHEET DATE ISSUED: 04/18/2008 DESIGNED BY: AOH DRAWN BY: AOH CHECKED BY: RAP ELECTRICAL POWER PLAN DRAWING NUMBER. PROCESSING AREA O1 RECEPTACLES AND COVERPLATES DESIGNATED "SF" SHALL BE WHITE IN COLOR. MOUNT WHERE SHOWN ON PLANS ON THE UNDERSIDE OF THE STOREFRONT SOFFIT WITH THE 4" SIDE PARALLEL TO THE STOREFRONT GLASS. SUPPORT BOX FROM STRUCTURE. O2 RECEPTACLES AND COVERPLATES IN "NON- SALES" SHALL BE WHITE IN COLOR. MOUNT ALL RECEPTACLES AT 15" A.F.F., EXCEPT AS NOTED ON PLAN. O3 CONDUIT FOR TRAFFIC COUNTER. INSTALL 1" CONDUIT FROM IFS ENCLOSURE TO THE MAIN ENTRY OF STORE AND FINISH CONDUIT WITH AN INSULATED BUSHING (INSULATED CAP) FOR FUTURE INSTALLATION OF THE TRAFFIC COUNTER. O4 INSTALL A DELIVERY BUZZER SYSTEM AS SHOWN ON DRAWINGS. ESD &C SHALL FURNISH A COMPLETE EDWARDS DELIVERY BUZZER SYSTEM, COMPLETE WITH TRANSFORMER, BUZZERS, LOUVERED COVERPLATES, AND PUSHBUTTON (WEATHERPROOF FOR OUTSIDE LOCATIONS). THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL NECESSARY JUNCTION BOXES, CONDUIT, AND WIRE TO COMPLETELY INSTALL THE DELIVERY BUZZER SYSTEM. ALL JUNCTION BOXES SHALL BE MOUNTED VERTICALLY. O TELEPHONE OUTLET IN WALL. INSTALL EMPTY 3/4" CONDUIT, WITH PULLWIRE, BACK TO TELCO SECTION OF IFS ENCLOSURE. TELEPHONE WIRE AND #RJ14C JACK FOR TWO LINE TELEPHONE BY OTHERS. MOUNT AT 15" A.F.F., EXCEPT AS NOTED ON PLANS. O EXTEND 1" TELEPHONE CONDUIT FROM SERVICE ENTRANCE AT DEMISING WALL TO TELEPHONE /DATA SECTION OF IFS ENCLOSURE. 07 SOUND SYSTEM. FURNISH AND INSTALL ALL CONDUIT AND JUNCTION BOXES, AND PERFORM ALL WORK AS INDICATED IN THE DETAIL. O8 FURNISH AND INSTALL A 3/4" CONDUIT WITH PULLWIRE FROM HVAC SECTION OF IFS ENCLOSURE, UP TO ABOVE CEILING. COORDINATE EXACT REQUIREMENT WITH MECHANICAL CONTRACTOR. (') QUADRUPLEX OUTLET FOR DATA, TELEPHONE, FAX, AND POLLING. INSTALL EMPTY 1" CONDUIT, WITH PULLWIRE, BACK TO TELCO SECTION OF IFS ENCLOSURE. DATA /TELEPHONE WIRE AND COVERPLATE BY OTHERS. 10 20 AMP, 120 VOLT, SINGLE PHASE ISOLATED DEDICATED CIRCUIT, 20 AMP #IG6300 -W RECEPTACLE, WITH ISOLATED THIRD WIRE GROUND, IN A SINGLE 1/2" CONDUIT BACK TO PANELBOARD SECTION OF IFS ENCLOSURE FOR COMPUTER TERMINAL. DO NOT SHARE ANY PART OF THIS CIRCUIT WITH ANY OTHER BRANCH CIRCUITS. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. 20 AMP, 120 VOLT CIRCUIT AND DUPLEX WHITE RECEPTACLE AND COVERPLATE FOR UTILITY POWER, IN A SINGLE 1/2" CONDUIT BACK TO PANELBOARD SECTION OF IFS ENCLOSURE. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. 12 20 AMP, 120 VOLT CIRCUIT AND QUAD RECEPTACLE FOR UTILITY POWER, IN A SINGLE 1/2" CONDUIT BACK TO PANELBOARD SECTION OF IFS ENCLOSURE. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. 13 IFS ENCLOSURE. ALL CONDUITS STUBBED INTO IFS ENCLOSURE SHALL BE INSTALLED IN A CLEAN AND NEAT MANNER. ANCHOR IFS ENCLOSURE ACCORDING TO MANUFACTURERS SPECIFICATIONS AND LOCAL CODES IN SEISMIC AREAS. REFER TO SPECIFICATIONS AND E05.1 FOR MORE INFORMATION. 14 REGISTER CASHWRAP /BACKWRAP COUNTER. PERFORM ALL WORK AS INDICATED IN THE DETAIL. 15 JUNCTION BOX INSTALLED AT 48" A.F.F. WITH FACE FLUSH TO DRYWALL AND 1/2" CONDUIT UP IN WALL TO ABOVE CEILING FOR TEMPERATURE T- STAT(S) /SENSOR(S) /CO2 SENSORS. COORDINATE EXACT REQUIREMENTS WITH MECHANICAL CONTRACTOR. MECHANICAL CONTRACTOR SHALL INSTALL ESD &C FURNISHED CONTROL CABLE FROM JUNCTION BOX TO HVAC UNITS. 16 MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL AIR DEVICE OR ACCESS PANEL TO BE USED AS ACCESS TO EQUIPMENT LOCATED ABOVE THE CEILING. THIS CONTRACTOR SHALL BE RESPONSIBLE TO ENSURE THAT A MINIMUM UNOBSTRUCTED FREE AREA OF 3 -FEET VERTICALLY AND 3 -FEET HORIZONTALLY IN ALL DIRECTIONS AROUND EQUIPMENT IS MAINTAINED TO ALLOW FOR INSTALLATION AND MAINTENANCE OF EQUIPMENT. IF THIS FREE AREA CANNOT BE OBTAINED, CONTACT THE ESD &C'S PROJECT MANAGER IMMEDIATELY. 17 20 AMP RECEPTACLE ® 42" A.F.F. FOR MICROWAVE. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT ESD &C PROJECT MANAGER FOR DIRECTION. 20 AMP RECEPTACLE 0 18" A.F.F. FOR REFRIGERATOR. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT ESD &C PROJECT MANAGER FOR DIRECTION. 19 JUNCTION BOX FOR WATER HEATER ELECTRICAL CONNECTION. FURNISH AND INSTALL CODE REQUIRED DISCONNECT SWITCH. COORDINATE EXACT LOCATION AND RELATED REQUIREMENTS WITH PLUMBING CONTRACTOR PRIOR TO WORK COMMENCEMENT. 11 :: C 21 DUCT MOUNTED SMOKE DETECTOR. 22 f1 ; ;. -; PP ON • R 25 120V, GFI, W.P. UNIT RECEPTACLE. FURNISH AND INSTALL CONDUCTORS AND CONDUIT FOR 120V POWER. 26 QUADRUPLEX RECEPTACLE, DUPLEX RECEPTACLE, AND COVERPLATES FOR SECURITY SYSTEM. MOUNT AT 55" A.F.F. TO MIDDLE OF QUADRUPLEX. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH -IN AND WORK COMMENCEMENT. 27 28 0: 8" A.f.F. fl S, AN /1 29 RECEPTACLES AND COVERPLATES MOUNTED AT 18" A.F.F., EXCEPT AS NOTED ON PLAN. RECEPTACLES SHOWN INSIDE CABINETS SHALL BE CENTERED ON THE BACK WALL OF THE CABINET. 30 iT ri i icu 31 GFI DUPLEX RECEPTACLE AND COVERPLATE FOR RESTROOM SHALL BE WHITE IN COLOR. MOUNT AT 42" A.F.F. O. RECEPTACLES AND COVERPLATES WITHIN SHOW WINDOW SHALL BE WHITE IN COLOR. MOUNT ABOVE SHOW WINDOW PLATFORM. REFER TO ARCHITECTURAL DETAILS FOR EXACT LOCATION AND MOUNTING REQUIREMENTS. 33 ELECTRIC WATER COOLER RECEPTACLE AND COVERPLATE SHALL BE WHITE IN COLOR. MOUNT AT 18" A.F.F. O. 30 AMP, 250 VOLT, 3 PHASE TWIST -LOCK RECEPTACLE AND STAINLESS STEEL COVERPLATE FOR DREAMSTEAMER. 35 SAW CUT /CORE DRILL FLOOR SLAB AS REQUIRED FOR UNDERSLAB CONDUIT. 36 , CENTERED ON THE PUCK FOCAL WALL. 37 RECEPTACLES IN DENIM AREA SHALL BE BLACK IN COLOR WITH STAINLESS STEEL COVERPLATES. 38 ENCLOSURE WITH SENSORMATIC POWER PACK AND ISOLATED GROUND TYPE DUPLEX RECEPTACLE MOUNTED ON VERTICAL FACE OF SOFFIT ABOVE CEILING. COORDINATE SENSORMATIC FREQUENCY WITH ADJACENT TENANT SENSORMATIC SYSTEMS. PAINT ENCLOSURE TO MATCH CEILING. 39 SENSORMATIC SYSTEM. REFER TO SENSORMATIC DETAIL FOR ELECTRICAL CONTRACTOR'S RESPONSIBILITIES. 40 RECEPTACLE AND COVERPLATES FOR WALKIES SHALL BE WHITE IN COLOR. WHEN ARCHITECTURAL FINISH ON WALLS IS P -9 OR P -2, RECEPTACLES AND COVERPLATES SHALL BE WHITE IN COLOR. VERIFY WALL FINISH WITH ARCHITECTURAL SHEETS. 42 FIRE ALARM CONTROL PANEL. ELECTRICAL CONTRACTOR TO SUPPLY 120V IG, DEDICATED RECEPTACLE. POWER PLAN CODED NOTES NTS 02DE022BONOTE B SHREMSHOCK 6130 S. WESTERVI 614-545 GINEERING, INC. ,1'< ROAD EXPIRES C,7 (` /� � W W � w<(- c w �¢ o o p o Z o3c n w r w U = U O ¢ wm� >\ W W \ Np(°il p ¢ D p 0 j Z Z O Z O Z /¢�1 Z Z Q? W(.J Z c Z Q r owpm p W O w a , N (n 0-1.i • ° W w a vw p 0- w °= w Z N W —Ldx 0 Q W 8M 6M1--Z1= <ar • 6.2 ES zo ar g (n i W ° W ¢ O W En Em z °Z O aW �z �W o�r O a or aJ N ! W 0 W o U � O ° �xo¢wxz d r U 0- CC w¢ 0000581 INFORMATION: VERIFY ALL FIELD CONDITIONS PRIOR TO BID ELECTRICAL POWER PLAN 1/4" = 1' -0" A N O 00 LO o co co W 0 REVISIONS: REQUIRED BY: PERMI (;EN I tl-� • INDICATES NO REVISION TO THIS SHEET DATE ISSUED: 04/18/2008 DESIGNED BY: AOH DRAWN BY: AOH CHECKED BY: RAP ELECTRICAL POWER PLAN DRAWING NUMBER: LOW VOLTAGE WIRING TO BE INSTALLED IN CONDUIT AS REQUIRED BY JURISDICTION OR LANDLORD. LOW VOLTAGE WIRING TO BE INSTALLED IN CONDUIT DUE TO HARD CEILING. NOTE: CONTRACTOR SHALL FIELD VERIFY LOW VOLTAGE WIRING IN CONDUIT PRIOR TO BID. LOW VOLTAGE WIRE IN CONDUIT SYMBOL -e bT EV 0 0 TC 0 DC MD „1�!1 O 4te, DESCRIPTION SINGLE RECEPT. W/ COVERPLATE DUPLEX RECEPT. W/ COVERPLATE QUAD. RECEPT. W/ COVERPLATE DUPLEX RECEPT. W/ COVERPLATE TELEPHONE OUTLET DATA /TELEPHONE OUTLET JUNCTION BOX MAGNETIC STARTER DISCONNECT SWITCH DELIVERY BUZZER TRANSFORMER DELIVERY BUZZER DELIVERY BUZZER PUSHBUTTON CEILING SMOKE DETECTOR DUCT SMOKE DETECTOR SINGLE PHASE MOTOR TRAFFIC COUNTER DUPLEX FLOOR RECEPT. W/ COVERPLATE TWIST -LOCK RECEPTACLE DOOR CONTACT MOTION DETECTOR TWO GANG FLOOR BOX W/ RECEPT. LID KEYPAD SENSOR THERMOSTAT ELECTRONICALLY OPERATED DAMPER NTS OODE023LONOTE MANUFACTURER & MODEL NUMBER 20 AMP, 120 VOLT 20 AMP, 120 VOLT 20 AMP, 120 VOLT DEDICATED DUPLEX RECEPTACLE ON ISOLATED GROUND, 20 AMP, 120 VOLT WHITE COLOR RJ14C TELE. JACK IN SALES AND NON -SALES AREA. WHITE COLOR PLATE IN SALES AND IN NON -SALES AREA. JUNCTION BOX, 4" X 4" X 2 1/8" DEEP MINIMUM FULL VOLTAGE STARTER IN A NEMA 1 ENCLOSURE, SIZE 1 MINIMUM HEAVY DUTY, FUSIBLE AND NON- FUSIBLE TRANSFORMER AT 8' -0" A.F.F. SEE FLOOR PLAN FOR MOUNTING HEIGHT PUSH BUTTON UNIT AT 48" A.F.F. SYSTEM CONNECTED CEILING MOUNTED PHOTOELECTRIC TYPE SMOKE DETECTOR SYSTEM CONNECTED DUCT MOUNTED PHOTOELECTRIC TYPE SMOKE DETECTOR COMPLETE WITH SAMPLING TUBES L REMARKS 20 AMP, 120 VOLT FLOOR BOX - ONE GANG BOX: B2414; LID: S3825 DREAMSTEAMER - (FURNISHED BY ESD &C) INSTALLED AT ALL EXIT DOORS, INCLUDING ROLLING GRILLES. CEILING OR WALL MOUNTED 20 AMP, 120 VOLT, HUBBELL TWO GANG FLOOR BOX (1) B4214, W/ HUBBELL RECEPTACLE LIDS; (1) S3826 AND (1) S3825, WITH SEPARATION FOR POWER AND DATA OUTLET. KEYPAD MOUNTED AT 4' -4" A.F.F. SEE FLOOR PLAN FOR LOCATION SINGLE GANG DRYWALL. BOX (2 "x4 ") FOR SENSOR AT 48" A.F.F. WITH FACE FLUSH TO SINGLE GANG DRYWALL. BOX (2 "x4 ") FOR THERMOSTAT AT 48" A.F.F. WITH FACE FLUSH TO REFER TO MECHANICAL DRAWINGS FOR SPECIFICATIONS. NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. SHOWN FOR REFERENCE ONLY. POWER REFERENCE SCHEDULE NTS OODE023KONOTE K ELECTRICAL RESPONSIBILITY SCHEDULE ITEM FURNISHED BY LANDLORD CONT'R. ESD&C VENDOR INSTALLED OR PERFORMED BY LANDLORD CONT'R. OTHER RE -USE EXISTING N/A REMARKS ELECTRICAL SERVICE / DISTRIBUTION MAIN OVERCURRENT DEVICE IN LANDLORD'S ELECTRICAL EQUIPMENT METER IN LANDLORD'S OR TENANT'S SPACE (VERIFY W/ POWER PLANS, RISER) C/T'S AND CABINET IN LANDLORD'S OR TENANT'S SPACE (VERIFY W/ POWER PLANS, RISER SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE I.F.S. ENCLOSURE (SWITCHGEAR ASSEMBLY) 277/480 VOLT PANEL STEP DOWN LINE TRANSFORMER & MOUNTING ACCESSORIES 120/208 VOLT PANEL(S) SMART BREAKER SYSTEM FOR LIGHTING CONTROL LIGHTING CONTROLLER WITH POWER SUPPLY AND OVERRIDE STATION BREAKER LOCKS LL LL LL LL LL IF IF IF IF IF EMS IF u. LL IL IL LL EC EC IF IF IF IF IF FIELD VERIFY PRIOR TO BID FIELD VERIFY PRIOR TO BID FIELD VERIFY PRIOR TO BID FIELD VERIFY PRIOR TO BID FIELD VERIFY PRIOR TO BID INSTALLED IN FACTORY INSTALLED IN FACTORY INSTALLED IN FACTORY INSTALLED IN FACTORY LANDLORD BUILDING MANAGEMENT SYSTEM AS REQUIRED BY ENGINEER MECHANICAL / PLUMBING EQUIPMENT COORDINATION POWER WIRING AND CONDUIT / PULL STRING TO ALL HVAC EQUIPMENT ROOF TOP UNIT - DISCONNECT SWITCH ROOF TOP UNIT - WEATHERPROOF GFI SERVICE REC. AIR HANDUNG UNIT CW AND OR HW, CW WITH ELECTRIC HEAT) - DISCONNECT SWITCH FAN CONTACTS AIR HANDLING UNIT (DX SPUT) - DISCONNECT SWITCH / FAN CONTACTS CONDENSING UNIT (DX SPUT) - DISCONNECT SWITCH CONDENSING UNIT (DX SPLIT) - WEATHERPROOF GFI SERVICE REC. FAN POWERED VAV / VAV SYSTEM (WITH OR WITHOUT ELECTRIC HEAT) - DISCONNECT SWITCH WATER SOURCE HEAT PUMP - DISCONNECT SWITCH TOILET EXHAUST FANS (FRACTIONAL HP) WITH . DISCONNECT SWITCH ELECTRONIC CONTROL DAMPERS - DISCONNECT SWITCH DUCT HEATERS EC EC EC EC EC MC AC AC AC AC EC AC ID EC EC EC MC EC MC AC AC AC AC WIRED BY EC AC LOW VOLTAGE SYSTEMS PAGING SYSTEM - HARDWARE ESIMINEMPINW ill" ULU PAGING SYSTEM - CONDUIT / PULL STRING BURGLAR / SECURITY SYSTEM - HARDWARE BURGLAR / SECURITY SYSTEM - CONDUIT / PULL STRING RF TECHNOLOGY SYSTEM - HARDWARE RF TECHNOLOGY SYSTEM - WIRE RF TECHNOLOGY SYSTEM - CONDUIT / PULL STRING CCTV / ALARM SYSTEM - HARDWARE CCTV / ALARM SYSTEM - WIRE CCTV / ALARM SYSTEM - CONDUIT / PULL STRING MUSIC SYSTEM - HARDWARE (SPEAKERS / CD PLAYER) MUSIC SYSTEM - WIRE MUSIC SYSTEM - CONDUIT / PULL STRING DEUVERY BUZZER SYSTEM - HARDWARE DEUVERY BUZZER SYSTEM - WIRE DEUVERY BUZZER SYSTEM - CONDUIT / PULL STRING A! IN P:i71 mai EC RF RF RC RC EC • WIRED BY EC, FINAL CONNECT. BY PS IF REQUIRED BY AUTHORITY HAVING JURISDIC. IF REQUIRED BY AUTHORITY HAVING JURISDIC. EC EC EC EC MS LD EC EC EC EC EC EC • IF REQUIRED BY AUTHORITY HAVING JURISDIC. IF REQUIRED BY AUTHORITY HAVING JURISDIC. IF REQUIRED BY AUTHORITY HAVING JURISDIC. IF REQUIRED BY AUTHORITY HAVING JURISDIC. MISCELLANEOUS ELECTRICAL ITEMS UGHTING FIXTURES AND LAMPS RECEPTACLES AND COVERPLATES FLOOR BOXES AND COVERS JUNCTION BOXES SENSORMATIC SYSTEM - HARDWARE SENSORMATIC SYSTEM - POWER WIRING AND CONDUIT / PULL STRING DATA AND TELEPHONE SYSTEMS - CABLE AND JACKS DATA AND TELEPHONE SYSTEMS - CONDUITS / PULL STRING TELEPHONE DEMARC PANEL - PROTECTION OF DURING CONSTRUCTION / RELOCATION DEMOUTION DUCT SMOKE DETECTOR MECHANICAL EQUIPMENT SHUT -DOWN RELAY FIRE ALARM SYSTEM CASHWRAP - POWER WIRING AND CONDUIT / PULL STRING ROWNG GRILLE - POWER WIRING AND CONDUIT / PULL STRING DREAMSTEAMER - POWER WIRING AND CONDUIT / PULL STRING AS -BUILT DRAWINGS EC EC TEL EC GC FAC FAC FAC EC EC EC EC LD LD LD SV EC EC EC EC EC EC TEL EC GC MC FAC FAC EC EC EC EC UNLESS OTHERWISE NOTED ON PLANS CALL ESD&C TO RELOCATE. DO NOT CUT WIRES. RECEPTACLE BY LD AC EC EMS FAC GC IF LD HVAC EQUIPMENT SUPPLIER ELECTRICAL CONTRACTOR ENERGY MANAGEMENT SYSTEM VENDOR FIRE ALARM CONTRACTOR GENERAL CONTRACTOR IFS SUPPLIER LIGHTING PACKAGE DISTRIBUTOR LANDLORD .; 1: 1 k • . 0k MC MS PC PS RC RF SC SSV MECHANICAL CONTRACTOR MUSIC SYSTEM VENDOR PLUMBING CONTRACTOR PAGING SYSTEM VENDOR RF TECHNOLOGY CONTRACTOR RF TECHNOLOGY SYSTEM VENDOR SECURITY CONTRACTOR SECURITY SYSTEM VENDOR SV SENSORMATIC VENDOR TEL TELEPHONE CONTRACTOR ANY ITEM NOT SHOWN IS THE RESPONSIBILITY OF CONTRACTOR. ELECTRICAL RESPONSIBILITY SCHEDULE NTS OODE023EOSCHD 1. REFER TO LANDLORD'S SPECIFICATIONS AND TENANT DESIGN CRITERIA FOR NECESSARY INFORMATION AND COORDINATION WITH OTHER TRADES. COORDINATE ALL WORK WITH ALL TRADES INCLUDED BUT NOT LIMITED TO MECHANICAL, PLUMBING, FIRE PROTECTION, AND STRUCTURAL CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT, ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. 2. ANY DISCREPANCY BETWEEN ESD &C DRAWINGS AND TENANT CRITERIA, ESD &C DRAWINGS SHALL TAKE PRECEDENCE. 3. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL INSTALLED ITEMS AND LOCATIONS ARE NOT EXACTLY PLACED AND ARE NOT TO BE SCALED. ALL CONDUITS SHALL BE RUN TO SUIT CONDITIONS IN THE FIELD. CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY ON THESE PLANS AND DO NOT NECESSARY REFLECT THE EXACT CONDUIT LOCATIONS. ALL CONDUITS SHALL BE RUN INSIDE SHELL OF BUILDING AND UNDER INSULATED CEILING TO AVOID HIGH AMBIENT TEMPERATURE CONDITION. 4. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO SCHEDULE ALL ELECTRICAL INSPECTIONS REQUIRED BY THE BUILDING DEPARTMENT AND SERVING UTILITIES, AND EACH CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OR HER PERMITS AND INSPECTION FEES. 5. BEFORE COMMENCING ANY WORK, CONTRACTORS SHALL REVIEW THE LATEST NATIONAL, STATE, AND LOCAL CODE REQUIREMENTS, INCLUDING LANDLORD CRITERIA, AND PERFORM THE WORK IN STRICT ACCORDANCE WITH THESE. IN CASE OF CONFLICT, THE STRICTER REQUIREMENTS WILL PREVAIL. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS OR HER BID. FOR THE PURPOSE OF SURVEYING EXISTING CONDITIONS, WHICH MAY AFFECT THE WORK TO BE DONE UNDER THIS SECTION, ANY DISCREPANCIES SHALL BE IMMEDIATELY REPORTED TO THE GENERAL CONTRACTOR, ESD &C, OR THE LANDLORD'S FIELD REPRESENTATIVE FOR CLARIFICATION. 7. AFTER BID, ANY QUESTIONS RELATING TO SPECIFIC M, E, OR P ISSUES ARE TO BE DIRECTED AS RFI'S THROUGH THE ESD &C PROJECT MANAGER. 8. SHOULD THE SPACE HAVE BEEN INACCESSIBLE FOR INSPECTION, CONTRACTOR MUST INDICATE SO ON HIS OR HER BID. 9. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR ANY CHANGE ORDERS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOBSITE AND /OR PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS OR HER BID. 10. THE CONTRACTOR, WITHIN FIFTEEN (15) DAYS OF THE AWARD OF THE CONTRACT, SHALL SUBMIT TO THE OWNER, SIX (6) COPIES OF A COMPLETE LIST OF MATERIALS AND EQUIPMENT PROPOSED FOR THE JOB INCLUDING ALL DATA, PART NUMBERS, RATING CAPACITY, SIZE, DIMENSIONS, ELECTRICAL DATA, GRADE, MANUFACTURER, AND ANY OTHER DESCRIPTIVE DATA FOR ALL EQUIPMENT OR SYSTEMS THAT DEVIATE FROM SPECIFIED ITEMS. ANY DELAYS OR COSTS DUE TO THESE DEVIATIONS, WILL BE THE RESPONSIBILITY OF THE CONTRACTOR. 11. CONTRACTOR SHALL REMOVE ALL ABANDONED WIRING WHICH IS NOT TO BE REUSED. ABANDONED WIRING SHALL BE DISCONNECTED AND REMOVED FROM CONDUIT OR RACEWAY. AS -IS PRACTICAL, CONDUIT AND /OR RACEWAYS SHALL REMAIN WITH PULL STRING AND CAPPED. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DISPOSAL OF ALL UNUSED OR ABANDONED MATERIALS AND EQUIPMENT AND ITS REMOVAL OFF THE TENANT'S AND LANDLORD'S PREMISES. 12. OWNER RESERVES THE RIGHT TO HAVE CONSTRUCTION REVIEWED BY AN OUTSIDE CONSULTANT PRIOR TO ACCEPTANCE OF THE PROJECT. 13. EACH CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP RELATED TO HIS OR HER WORK FOR A MINIMUM PERIOD OF ONE YEAR FROM THE DATE WHICH THE OWNER ACCEPTS THE PROJECT. THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER OR TENANT, SHALL CORRECT ANY DEFECTS IN MATERIALS OR WORKMANSHIP DURING THIS GUARANTEE PERIOD. 14. EACH CONTRACTOR SHALL BE RESPONSIBLE AND ENSURE A CLEAN INSTALLATION, ESPECIALLY IN EXPOSED CEILING AREAS. THE FINAL APPROVAL OF THIS WORK WILL BE ISSUED BY ESD &C PROJECT MANAGER. 15. PROVIDE THREE SETS OF "AS- BUILT" DRAWINGS AND TWO BOUND SETS OF ALL OPERATIONS MANUALS, DIAGRAMS, SERVICE CONTRACTS, AND GUARANTEES TO ESD &C PRECEDENT TO FINAL PAYMENT. A REPORT PREPARED BY AN INDEPENDENT AIR BALANCE CONTRACTOR, HIRED BY GC, MUST BE INCLUDED IN THE CLOSEOUT PACKAGE. 16. THE ABBREVIATION "ESD &C ", WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS, SHALL REFER TO "EXPRESS BRANDS STORE DESIGN AND CONSTRUCTION ". 17. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS OR HER SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 18. THESE PLANS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT ELECTRICAL PLAN CHECK DIVISION AND THAT DIVISION'S STAMPED APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PLANS. 19. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK. 20. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION. 21. DESIGN AND CIRCUITRY MAY BE BASED ON AS -BUILT DRAWINGS. GC AND ELECTRICAL CONTRACTOR SHALL VERIFY ACCURACY OF AS -BUILT DRAWINGS. IN CASE OF DISCREPANCY, ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES, MISCELLANEOUS FITTINGS, ETC. FOR A COMPLETE AND OPERABLE SYSTEM FOR HOME RUNS SHOWN. BRANCH CIRCUIT INSTALLATION SHALL COMPLY WITH SPECIFICATIONS AND LATEST N.E.C. 22. WHERE PRACTICAL, AND WHERE CONDUIT CONDITION WARRANTS, CONTRACTOR MAY REUSE APPROPRIATE EXISTING CONDUIT SYSTEM. HOWEVER, IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CORRECT ANY AND ALL EXISTING CODE VIOLATIONS IN CONDUIT SYSTEMS TO BE REUSED. CONTRACTOR MUST OBTAIN THE ESD &C PROJECT MANAGER'S PERMISSION IN WRITING. 23. IF APPLICABLE, RECONNECT, COMPLETE, AND MAKE OPERABLE ALL EXISTING LIGHTING, RECEPTACLES, AND CIRCUITRY. 24. PRIOR TO INSTALLING ANY UNDERGROUND CONDUIT, VERIFY CONDUIT SIZES AND POINTS OF SERVICE WITH THE SERVING UTILITIES. 25. ALL CONDUCTORS ARE TO BE STANDARD ANNEALED COPPER CONDUCTORS WITH TYPE THHN INSULATION, UNLESS NOTED OTHERWISE, AND SHALL RUN FROM POINT TO POINT IN APPROVED CONDUIT. ALL CONDUITS, WHEN EXPOSED IN AREA WITH NO CEILING (EXCEPT STOCKROOM AREAS), SHALL BE INSTALLED IN RACKED FORM, WITH FITTED CONDUIT AND PARALLEL TO STRUCTURAL MEMBERS. 26. ALL CONDUCTORS SHALL BE PHYSICALLY IDENTIFIED AT EACH END FOR CIRCUIT USAGE AND CONTINUITY. 27. GENERALLY, ALL CONDUITS SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT SHALL BE ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY ESD &C'S PROJECT MANAGER. PAINTING OF CONDUITS, NOTED ON DRAWINGS OR SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR. ELECTRICAL GENERAL NOTES NTS OODE023CONOTE C 1. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU- WIRING" WHERE AND WHENEVER POSSIBLE. 2. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 3. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 100' -1" TO 150' -0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 150' -1" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 250' -0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. 4. PLACEMENT OF ALL RECEPTACLES IN THE SALES AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS), UNLESS OTHERWISE NOTED. IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH ESD &C'S PROJECT MANAGER PRIOR TO ROUGH IN. 5. ALL RECEPTACLES AND COVERS (DUPLEX, QUADRAPLEX, ETC) SHALL BE THE COLORS AS NOTED IN THE ELECTRICAL POWER PLAN NOTES AND SCHEDULES. 6. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 7. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT ESD &C PROJECT MANAGER. 8. ELECTRICAL CONTRACTOR SHALL PROVIDE A COMPLETE FIRE ALARM SYSTEM LAYOUT (SEE SHEETS F01.1, F01.2, AND F01.3) AS REQUIRED BY THE AUTHORITIES HAVING JURISDICTION AND ALL APPLICABLE CODES, AND COMPATIBLE WITH THE LANDLORD'S FIRE ALARM SYSTEM. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR INFORMING THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE IN BID. NO ADDITIONAL MONIES SHALL BE AWARDED FOR TIE -IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF BID, WITHOUT A SEPARATE LINE ITEM. 9. ANY PENETRATION THROUGH THE ROOF OR WALL WITH CONTROL WIRING MUST BE SLEEVED IN A CONDUIT. 10. ALL 24 VOLT COMMUNICATION AND /OR SENSOR WIRING ASSOCIATED WITH HVAC SYSTEM SHALL BE FURNISHED BY HVAC EQUIPMENT MANUFACTURER AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL FINAL CONNECTIONS SHALL BE BY MECHANICAL CONTRACTOR. ALL WIRING AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E.C., LOCAL CODE, AND LANDLORD REQUIREMENTS. 11. FURNISH AND INSTALL GROUND WIRE CONNECTION (BY -PASS) BETWEEN WATER METER PLUMBING END PIPE USING CLAMP CONNECTORS. MAKE SURE PLUMBING METALLIC WATER PIPE IS SECURELY GROUNDED AS PER N.E.C. AND LOCAL CODES. 12. IFS ENCLOSURE FURNISHED BY ESD &C AND INSTALLED BY ELECTRICAL CONTRACTOR IS HEREIN DESCRIBED: a. EQUIPMENT NOTED HAS BEEN PREPURCHASED BY EXPRESS STORE DESIGN & CONSTRUCTION. b. UNIT WILL BE SHIPPED TO THE PROJECT IN MULTIPLE SECTIONS AND THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR OFF- LOADING OF EQUIPMENT, INSPECTION OF EQUIPMENT FOR DAMAGES, VERIFICATION OF EQUIPMENT RECEIVED, ENSURING THAT THE EQUIPMENT RECEIVED IS COMPLETE AND MEETS THE SCHEDULED PANELS FOR THE PROJECT, MOVING AND MOUNTING OF SECTIONS AS WELL AS REASSEMBLING OF SAME INTO ONE COMPLETE UNIT PER MANUFACTURER'S REQUIREMENTS. c. ELECTRICAL CONTRACTOR IS TO CONNECT ALL PROVIDED INTERCONNECTING CABLES BETWEEN SECTIONS AND TORQUE CONNECTIONS PER MANUFACTURER'S REQUIREMENTS. d. ELECTRICAL CONTRACTOR IS TO CONNECT LIGHTING BRANCH CIRCUITS TO APPROPRIATE LOAD TERMINALS PROVIDED WITHIN IFS ENCLOSURE PER LIGHTING ZONES INDICATED IN THE PANEL SCHEDULE (I.E: ZONE A, B, C, AND D). LINE SIDE WIRING AND LIGHTING CONTROL WIRING WILL BE PREWIRED BY MANUFACTURER AT FACTORY. COORDINATE EXACT TERMINAL NUMBER FOR EACH CIRCUIT CONNECTION WITH MANUFACTURER'S DRAWINGS. e. ALL LIGHTING, RECEPTACLE, AND MISCELLANEOUS BRANCH CIRCUITS NOT SPECIFIED AS BEING CONTROLLED ARE TO BE WIRED DIRECTLY TO THE CORRESPONDING BRANCH BREAKER IN THE DESIGNATED PANEL. f. ALL CONNECTIONS WITHIN THE TELEPHONE /DATA SECTION AND HVAC CONTROL SECTION OF THE IFS ENCLOSURE ARE TO BE PERFORMED BY OTHERS. 13. THE GENERAL CONTRACTOR'S FIRE SPRINKLER SUB - CONTRACTOR SHALL DESIGN AND INSTALL FIRE SPRINKLER SYSTEM CONFORMING TO LANDLORD'S CRITERIA, TENANT'S REQUIREMENTS, AND PER LOCAL CODES AND NFPA STANDARDS. 14. CENTER ALL FIXTURES IN CEILING TILE WHERE APPLICABLE. 15. THE ELECTRICAL AND TELEPHONE SERVICES SHALL BE INSTALLED TO THE REQUIREMENTS OF THE SERVING UTILITIES. THE MAIN SERVICE SHALL BE ABLE TO WITHSTAND THE AVAILABLE SHORT CIRCUIT CURRENT INDICATED (AIC) ON THE ONE -LINE DIAGRAM. 16. CONTRACTOR SHALL PROVIDE CUT SHEETS TO ESD &C FOR ALL EQUIPMENT AND DEVICES FURNISHED BY THE CONTRACTOR THAT DEVIATE FROM SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES. 17. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND ARCHITECT FOR LOCATION, RESTRICTION, AND REQUIREMENTS OF ALL CONCRETE SAW CUTS. SAW CUTS SHALL BE PATCHED TO MATCH EXISTING CONCRETE. 18. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. POWER PLAN CONSTRUCTION NOTES NTS OODE023AONOTE A SHREMSHOCK:< 6130 S. WESTERVI# 614- 545 GINEERING, INC. AD ti�CE A. Plq,gr/ W AS tt "Go ' 43084 4Zt'S 1S cv'" O r %348 z 0 z cx: w O u) co W ce It O < In °2g N V, r O W U 0 L) m w .-. ; W Z <000 U =. z N C7 V) Z Z O Z o�om � } W O W W W a O d � � EL, N Q. W VI W lJ O U W W r W .Wy 3 a "' Z N m Z W 0- W= C7 Q : i r0 Z rz 1- ¢ :L.:: Z . rw 3„ 1L. Z • W • ix<vl aw Zz <_ .. =p ✓, i �= O • O ,,, ce 00 W O Z W :CCU _ CC Z1Q-¢ m i V O W W W U O W Z O d < 0 n_ S O W x Z d r U a� w< Z O W r.2 I";'- r Z U N uJ 0 0 W X 0 0 v/ o 2 0 U W W C. W i- d r W S ,- Z W = a 00 N O DO LO rn 0 o :00 op f .��� r O O 1,01 EWE eN CODE COMPLIANCE NFPA 70 -NEC MAY - 2008 0 PROJECT INFORMATION: City Of Tukwila BUILDING DIVISION F- CC W 1- z W U I� J D d CO O CO 2 CO Cn.-- ® Z� J W W M F- N W IA can- W 1- 0 LLJ 1- Er LL Z O ad O u) C] V) L J REVISIONS: REQUIRED BY: DATE RECEIVED c1-1YU1- IUKWIL APR 2 9 2008 PERMIT CENTER. . INDICATES NO REVISION TO THIS SHEET DATE ISSUED: 04/18/2008 DESIGNED BY: AOH DRAWN BY: AOH CHECKED BY: RAP ELECTRICAL POWER PLAN NOTES DRAWING NUMBER: SHREMSHOCK• ENGINEERING, INC. 6130 S. WESTERVILLEI OH 4308i 614-545 1 - - 1` 461 —‹ - - : L'c'L LI: a ( n 0 La ,- 0 li :: 5.: 1 Z V /.. l . 1 4" 73: 0,0 2= , : .:› , i -\. 0:891:,,v,122.!,._. - Z '71 W 2 1 - . ti O!'''. 'ja = xi z i ;:c nv .; C::: -419' ": :::-LXL49-- . 4! :7> -:2-1191 - .2: . . ?--C: '71' "7L . L J L ' "I: I! c! :uj°5 '2 0 Cri_ 1- 8 1:1 ..1 E' Wcc L>< <CX :).< ": ,g. : !,_ : 1-.: E !,,, .: c!"'>,35)!LAJF- ! : ! L.+ ‹,--,u :6" a., : "j. (1) .< —v 9c : ,. El : 3 „ z 01 r- I— (1) Is , 0 0 m 1 a J I= I W a J L1J . . < 0 0 o en ,= g . - - '.. • , 2 R. L . . , i i i i L. ' '-' - 11 Ell rc z LaJ '. 6 " L.C1 < JC 4!0. 1;612:. tz :16 g o 90 11 i3 Co !7.2 Ed Di n ...... Li RESTROOM ALCOVE (NO Y. • .. " • • A-6 F.R.5. F.R.4. F.R.3. • F.R.2. F.R.1. NOTE: REFER TO SHEET E03.2 FOR LIGHTING PLAN CODED NOTES. NOTE: REFER TO SHEET E05.1 FOR PANEL SCHEDULES AND LIGHTING ZONE DESIGNATIONS. NOTE: REFER TO SHEET E03.3 FOR ELECTRICAL LIGHTING SCHEDULE AND LIGHT DESCRIPTIONS. NOTE: GENERAL CONTRACTOR SHALL VERIFY CEILING FIRE RATING WITH ARCHITECT, AND BOX OR TENT ALL RECESSED LIGHT FIXTURES, IF REQUIRED, TO MAINTAIN CEILING FIRE RATING. NOTE: ELECTRICAL CONTRACTOR SHALL REFER TO ARCHITECTURAL SHEETS FOR MOUNTING HEIGHTS AND INSTALLATION DETAILS FOR SUSPENDED LIGHTING IN DENIM AND NON-SALES AREAS. DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: VERIFY ALL FIELD CONDITIONS PRIOR TO BID (EM /NL) (EM /NL) IPROCESSING AREA O ELECTRICAL CONTRACTOR SHALL INSTALL OCCUPANCY MOTION SENSOR SWITCH FOR CONTROL OF LIGHTS AS SHOWN. ELECTRICAL CONTRACTOR SHALL SET SWITCH FOR 15 MINUTES. O CLCCTRICAL CONTRACTOR SIIALL It I.WI( WTC AMfl CVArT 1 n/`ATIrUJ i • •D MOUNTING XHAUST FAN SHALL BE CONTROLLED BY SAME DEVICE THAT CONTROLS LIGHTS IN RESTROOM. O4 FURNISH AND INSTALL JUNCTION BOX, TOGGLE DISCONNECT SWITCH IN NON- VISIBLE LOCATION, AND FINAL CONNECTION FOR 120 VOLT SIGN. SIGN IS FURNISHED WITH INTERNAL GROUND FAULT PROTECTION BY SIGN MANUFACTURER PER N.E.C. ARTICLE 600.23(B). VERIFY EXACT LOCATION OF JUNCTION BOX WITH SIGN DETAILS ON ARCHITECTURAL DRAWINGS. (REUSE EXISTING JUNCTION BOX AND CONDUIT INTO SPACE IF ALREADY INSTALLED. VERIFY IN FIELD EXACT LOCATION ON CANOPY). NOTE: THE CIRCUIT FOR SIGNAGE MUST BE A DEDICATED ISOLATED 4 -LINE CIRCUIT CONSISTING OF HOT, NEUTRAL, AND TWO (2) GROUND WIRES LEADING DIRECTLY TO THE PANEL. O CIRCUIT EXIT AND EMERGENCY /NIGHT LIGHT BATTERY BACKUP BALLAST TO LOCAL CIRCUIT AHEAD OF ALL SWITCHING. O ELECTRICAL CONTRACTOR SHALL MOUNT EXIT SIGN /EMERGENCY LIGHT TO JUNCTION BOX ATTACHED TO CONDUIT HANGING FROM STRUCTURE ABOVE. REFER TO ARCHITECTURAL SHEETS FOR MOUNTING HEIGHTS AND EXACT LOCATIONS. 07 SPEAKERS IN DENIM AREA SHALL BE WALL MOUNTED WITH BOTTOM OF SPEAKER AT 14' -6" A.F.F. VERIFY ALL REQUIREMENTS WITH ARCHITECT AND EQUIPMENT MANUFACTURER PRIOR TO WORK COMMENCEMENT. O FIXTURE SHALL BE MOUNTED AT 8' -B" TO BOTTOM OF FIXTURE. O ELECTRICAL CONTRACTOR SHALL SUPPLY AND INSTALL JUNCTION BOX AT DENIM WALL SIGN LOCATION. CONTACT SIGN DESIGNER FOR EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK. 10 EXIT SIGN SHALL BE TOP MOUNTED TO J -BOX SUSPENDED FROM CEILING, WITH BOTTOM OF FIXTURE 12' -2" A.F.F. AND 6" AWAY FROM FINISHED SOFFIT. • LIGHTING PLAN CODED NOTES NTS 02DE032DONOTE VERIFY ALL FIELD CONDITIONS PRIOR TO BID rREVIEWED FOR C ■ODE COMPLIANCE NFIPA 70 At ( -u 2108 City Of Tukwila BUILDING DIVISION_... FIRE ALARM PLAN 1/4" = 1' -0" A SHREMSHOCK::. 6130 S. WESTERVI 614 -545 GINEERING, INC. AD O z z 'Q W (aiU) 0 co co W W G. 00 X col 13 .D s = p Q w I -y Z c. ZO Z Z ¢ �O� 0.,-, y Z oZ O 7 W Z W= 0 U s �a !!:.',_:1 : mwo- II a O W Fw y W U WKO � w W ~ 2 d p z v 'S- m „, • Z W Z 0 • c --. • ¢ O q' F Z U Q ? WU LJ ° J S U ¢ Ai:i Z z 2 tO `p W W Z -~ 2 7 ° W 0 °y 0 O Z O � - 1- W 2 m z!�oy� :�o 42U � wZ V = ZZ U Z Z 2K TY3o m N _I_= Wa0 -W N O �Ur R,,,, a F-. . (1-.TWmJ 0 .. 0000581 INFORMATION: 1- w a. N 0 CO LC) 0') O Y GO DO o- O O REVISIONS: REQUIRED BY: DATE RECEIVED CITY OF TUKWLA APR 2 9 7008 Pc wii� O1...4 * INDICATES NO REVISION TO THIS SHEET DATE ISSUED: 04/18/2008 DESIGNED BY: AOH DRAWN BY: AOH CHECKED BY: RAP ELECTRICAL LIGHTING PLAN DRAWING NUMBER: Si) FIRE RATED PENETRATION SCHEDULE TYPE OF PENETRATION CONCRETE OR MASONRY GYPSUM BOARD /FRAME "SPECSEAL FIRESTOP" PRODUCTS FLOORS UL SYSTEM # WALLS UL SYSTEM # FLOORS UL SYSTEM # WALLS UL SYSTEM # METAL CONDUITS MAX. 4" CAJ10B0 CAJ1080 FC1010 WL1049 SSS100 SEALANT CAJ1213 WJ1030 WL1088 LC150 SEALANT CAJ1198 CAJ1198 WL1062 PEN300 SILICONE PVC CONDUIT 2" AND SMALLER CAJ2031 WJ2018 FC2032 WL2093 SSS100 SEALANT PVC CONDUITS 2" THRU 4" CAJ2038 CAJ2038 WL2029 FIRESTOP COLLAR CAJ2045 CAJ2045 FIRESTOP COLLAR CAJ2124 CAJ2124 FC2033 WL2059 WRAP STRIPS CABLE TRAY STEEL OR ALUMINUM CAJ4029 WJ4021 WL4008 FIRESTOP PILLOWS CAJ4020 CAJ4020 FIRESTOP MORTAR WJ4009 WL4005 SSS100 SEALANT ELECTRICAL BUS DUCT CAJ6003 CAJ6003 PEN300 SILICONE CAJ6008 CAJ6008 WL6001 SSS100 SEALANT MAX. 3" CABLE BUNDLES CAJ3154 WJ3022 WL3076 SSS100 SEALANT NOTES: ABOVE ARE BASED ON PROVIDING A 1 & 2 HOUR RATED FIRESTOP. REQUIRED, CONTACT FIRESTOP PRODUCT MANUFACTURER FOR DESIGN ABOVE ARE BASED ON "SpecSeal Flrestop" PRODUCTS FROM OR APPROVED EQUAL PRODUCTS FROM "3 -M" OR HILTI, INC. 1. ALL U.L. LISTED SYSTEMS SHOWN WHERE 3 HOUR RATING IS MODIFICATIONS. 2. ALL U.L. LISTED SYSTEMS SHOWN SPECIFIED TECHNOLOGIES, INC. FIRE PENETRATION SCHEDULE NTS OODE033MOSCHD S ELECTRICAL LIGHT FIXTURE SCHEDULE SYMBOL A DESCRIPTION RECESSED DOWNLIGHT TRACK LIGHT TRACK HEAD SHOW WINDOW MANUFACTURER & MODEL NUMBER REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION SYMBOL A4 A9 B6 BQ C2 CA FG DESCRIPTION 6" DIAMETER RECESSED COMPACT FLUORESCENT DOWNUGHT, CLEAR CONE, MATTE FINISH, ELECTRONIC BALLAST, SELF FLANGED REFLECTOR 7' DIAMETER RECESSED HALOGEN 'A' LAMP DOWNLIGHT, CLEAR CONE, MATTE FINISH, SELF FLANGED REFLECTOR 4" DIAMETER RECESSED ADJUSTABLE MR16 ACCENT LIGHT, CONICAL DROP HINGE LAMP, INDUSTRIAL SILVER FINISH, 358' ROTATION, 85' ADJUSTABIUTY, INTEGRAL ELECTRONIC TRANSFORMER, SECURE HOUSING TO STRUCTURE 3" DIAMETER RECESSED ADJUSTABLE MR16 ACCENT LIGHT, CONICAL DROP HINGE LAMP, MATTE WHITE FINISH, 358' ROTATION, 85' ADJUSTABIUTY, INTEGRAL ELECTRONIC TRANSFORMER, SECURE HOUSING TO STRUCTURE 4" DIAMETER RECESSED HALOGEN MR16 LENSED WALLWASHER, CLEAR CONE, MATTE FINISH, SELF FLANGED REFLECTOR CERAMIC METAL HALIDE TRACK HEAD, INTEGRAL ELECTRONIC BALLAST, COLOR CORRECTION REFLECTOR, SNOUT, WHiTE FINISH 4' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST. 1 LAMP IN SECTION. WiTH EMERGENCY PACK. WIRE GUARD. MANUFACTURER & MODEL NUMBER .HALO—PORTFOLIO: C7032 -1E- 7001 41. LIGHTOUER— CALCULFTE: B021CCDP. S6132BU JUNO: CV6- 126 /32T- 600C —SF HALO — PORTFOLIO: HD7- 7701 —H -75 UGHTOUER— CALCUUTE: C7055CCDP— C700 -75 JUNO: TC906- 643C —SF -75 RSA: MLV3087, C500 /EL/MBA -35 CON —TECH: LVR316. CTR325 —S -35 RSA: MLV3084. C500 /EL/MBA -35 CON —TECH: LVR316. CTR325 UTHONIA— GOTHAM: DLV WSH MR16 4AC LD 120 -35 AMERLUX: CYTL 20 T4GU6.5 E WT TJ1 120 FL DB2690 SN WT MERCURY: NM- 132— OCT —C— ELB- 120V —EMPI( HEIGHT 10 7/8" 10 5/8" 3 1/2" 3 1/2' 6 3/4" 5 7/16' 3 1/4" LAMP 32 watt, T4, 4Pin GX24q -3 Base, Triple Compact Fluorescent, 3000K, 82CRI, 10,000 Hrs. 75 watt, BT -15. Medium Screw Base, Tungsten Halogen, 3,000 Hrs. 35 watt HIR, MR16, 2 Pin GX 5.3 Base, Quartz Halogen. Narrow Flood 24', 5000 Hrs. 35 watt HIR, MR16, 2 Pin GX 5.3 Base, Quartz Halogen, Narrow Flood 24', 5000 Hre. 35 watt HIR, MR16, 2 Pin GX 5.3 Base, Quartz Halogen. Narrow Flood 24', 5000 Hrs. WATTAGE 20 watt, Ceramic Metal Halide, T4, GU6.5 TAL base, 3000K, 80CRI 32 Watt, T8. Medium Bi —Pin Bose, Unear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. 36 WATTS 75 WATTS 35 WATTS 35 WATTS 35 WATTS 25 WATTS 32 WATTS VOLTAGE 120 VOLTS 120 VOLTS 12/120 VOLTS 12/120 VOLTS 12/120 VOLTS 120 VOLTS 120 VOLTS SHREMSHOCK 6130 S. S WESTERVI;: 614- 545 REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION S1 A EM FLUORESCENT STRIP EMERGENCY FLUOR. STRIP REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION A FLUORESCENT TROFFER REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION A SCONCE FR 4' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION FT WIRE GUARD REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION 8' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION, (2) 4' SECTIONS TANDEM WIRED ON ONE BALLAST, QUICK CONNECT PLUGS WIRE GUARD MERCURY: MM- 132— OCT —C— ELB -120V. WG —MM -140 METALUX: SN- 132 —LRS- 120 —EBBI. WG /SN -4FT DURAY: EQH1132. WG -3" MERCURY: MM- 132— OCT /8T —C— ELB -120V. (2)WG —MM -140 METALUX: BTSN- 132 —LRS- 120 —EB81. (2)WG /SN -4FT DURAY: E0H1132TZ. (2)WG -3" 3 1/4" 3 1/4' 32 Watt, T8, Medium Bi —Pin Base, Unear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. 32 Watt, T8, Medium Bi —Pin Base, Unear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. 32 WATTS 120 VOLTS 58 WATTS 120 VOLTS REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION DECORATIVE PENDANTS REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION FU 12' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION, (3) 4' SECTIONS TANDEM WIRED ON ONE BALLAST, QUICK CONNECT PLUGS X2 X9 MS $D NL EM trcI EXIT SIGN EMERGENCY LIGHT, SEMI — RECESSED EMERGENCY LIGHT, RECESSED REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION REFER TO THIS SHEET FOR LIGHTING FIXTURE DESCRIPTION SWITCH SWITCH — MOTION SENSOR HUBBELL WS1277W2 PASSIVE INFRARED, DOUBLE POLE, SINGLE THROW WALL SWITCH SENSOR WITH TWO SEPARATE RELAYS. WHITE COLOR FINISH. SWITCH — DIMMER HUBBELL S61W, SINGLE POLE, SINGLE THROW WALL DIMMER SWITCH. WHITE COLOR FINISH. NIGHT LIGHT EMERGENCY LIGHTING FIXTURE CEILING EXHAUST FAN TRAFFIC COUNTER €11 SM SPEAKERS SUBWOOFER SECURITY CAMERA VIEW MONITOR FOR SECURITY SYSTEM GC160, 120 VOLT, 1 PHASE, 115 WATTS NOTE: WALL MOUNTED /CEILING MOUNTED FW H5 N1 T2 WIRE GUARD 16' SURFACE MOUNTED BARE LAMP FLUORESCENT STRIP, ELECTRONIC BALLAST, 1 LAMP IN SECTION, (4) 4' SECTIONS TANDEM WIRED ON ONE BALLAST, QUICK CONNECT PLUGS WIRE GUARD 4' DIAMETER RECESSED QUARTZ HALOGEN DOWNUGHT, INTEGRAL ELECTRONIC TRANSFORMER, CLEAR CONE, CHROME TRIM, NEW CONSTRUCTION HOUSING 1' X 4' SURFACE MOUNTED SINGLE LAMP FLUORESCENT TROFFER, PRISMATIC ACRYUC LENS, ELECTRONIC BALLAST PAR30 FRONT LOADING GIMBAL RING TRACK HEAD, MATTE WHITE FINISH NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. SHOWN FOR REFERENCE ONLY. LIGHTING SYMBOL SCHEDULE NTS 1'f OODE033KOSCHD r TA MR16 GIMBAL RING TRACK HEAD, INTEGRAL ELECTRONIC TRANSFORMER, MATTE WHITE FINISH MERCURY: MM- 132 —OCT /121 —C— ELB -120V. jMG —MM -140 J�ETALUX: 12TSN- 132 —LRS- 120 —EB81. (3)WG /SN -4FT DURAY: EOH1132TZ -12'. (3)WG -3" 3 1/4' MERCURY: MM- 132— OCT /16T —C— ELB -120V, f4)WG —MM -140 ETALUX: 16TSN- 132 —LRS- 120 —EB81. (4)WG /SN -4FT DURAY: EQH1132TZ -16'. (4)WG -3° RSA: MLV2051. C500 /EL /MBA -20 CON —TECH: LVR316 -5. CTR311— GY —P -20 MERCURY: M30- 132— OCT -9A— ELB -120V METALUX: MC -132A- 120 —EB81 DURAY: S14132PFLA CON —TECH: CTL2830P -40 JUNO: V689WH -50 HALO: L1730P -50 JNDY: 133T —W -50 3 1/4' 5 1/2' 3 3/4" B° CON —TECH: CTL8116P. LA2050P -35 JUNO: V696WH. T538WH -35 JIAL.O: L2717P -35 JNDY: 78TL —W -35 3 3/4' 32 Watt, T8, Medium Bi —Pin Base, Unear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. 32 Watt, T8. Medium Bi —Pin Base, Unear Fluorescent, 3000K, 82 CRI, 20,000 Hre. 20 watt, T4, GY6.35 Bi Pin Base, Halogen, 3000 Hrs. 32 Watt, T8, Medium Bi —Pin Base, Unear Fluorescent, 3000K, 82 CRI, 20,000 Hrs. 40 watt, PAR30, Medium Screw Base, IRC, Flood 25', 4200 Hrs. 85 WATTS 112 WATTS 20 WATTS 32 WATTS 40 WATTS 120 VOLTS 120 VOLTS 12/120 35 watt HIR, MR16, 2 Pin GX 5.3 Base, Quartz Halogen, Narrow Flood 24', 5000 Hrs. 35 WATTS VOLTS 120 VOLTS 120 VOLTS 120 VOLTS TD 4 1/4" DIAMETER TRACK MOUNTED PAR30 METAL HALIDE TRACKHEAD, INTEGRAL ELECTRONIC BALLAST, MATTE WHITE FINISH CON —TECH: CTL1610M /39MH —P 10 1/2" 39 Watt, PAR30, Medium Base, Metal Halide, Clear, 3000K, 85 CRI, Flood 30', 9000 Hre. 46 WATTS 120 VOLTS . LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE "THRU— WIRING" WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU— WIRING ". ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHOULD BE INCLUDED IN BID. • ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND ASSOCIATED LAMPS FURNISHED BY ESD &C. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM PER GC DIRECTION. LIGHT FIXTURE SPECIFICATIONS MAY VARY. IF THIS IS THE CASE, CONTRACTOR IS TO CALL ESD &C PURCHASING AGENT WHO WILL THEN CALL THE DISTRIBUTOR FOR EXACT SPECIFICATION OF LIGHTING FIXTURES. IF THE CEILING SYSTEMS ARE FIRE RATED, ELECTRICAL CONTRACTOR IS TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH ESD &C. 1 EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER LOCAL AND LATEST NATIONAL ELECTRICAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL VOLTAGE WITH BATTERY BACK UP (120/277 VOLT INPUT). INSTALL A CENTRAL BATTERY SYSTEM WHERE THE USE OF INDIVIDUAL BATTERY UNITS ARE PROHIBITED BY LOCAL CODES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT ESD &C PROJECT MANAGER FOR DIRECTION. ALL LIGHTING CIRCUITS UP TO 100' -0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM 100' -1" TO 150' -0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS 150' -01" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251' -0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. i ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. EXIT /EMERGENCY LIGHTS AT STOREFRONT ARE TO BE CEILING MOUNTED AND CENTERED OVER OPENING. EXIT /EMERGENCY LIGHTS AT DOOR TO NON —SALES SHALL BE CEILING MOUNTED AND CENTERED ABOVE DOOR. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT THE ESD &C PROJECT MANAGER FOR DIRECTION. 7 IT WILL BE THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO UNLOAD INVENTORY AND STORE LIGHTING PACKAGE. THE ELECTRICAL CONTRACTOR WILL ALSO SHIP ANY EXCESS MATERIALS BACK TO THE ELECTRICAL PACKAGE DISTRIBUTOR. B. ELECTRICAL CONTRACTOR SHALL REFER BACK TO ARCHITECTURAL SHEETS FOR MOUNTING HEIGHTS OF ALL WALL MOUNTED EMERGENCY EGRESS AND EXIT FIXTURES. IF PLAN LOCATION IS NOT ACCEPTABLE, IMMEDIATELY CONTACT ESD &C PROJECT MANAGER FOR DIRECTION. 9 REFER TO ARCHITECTURAL DRAWINGS FOR COORDINATION AND EXACT LOCATION OF EXIT SIGNS, EMERGENCY LIGHTING FIXTURES, SPEAKERS, DIFFUSERS, AND OTHER ARCHITECTURAL ELEMENTS, 10. THE ELECTRICAL CONTRACTOR MUST INCLUDE IN THE BID TWO (2) HOURS OF START —UP TIME FOR THE LIGHTING CONTROL SYSTEM. THE ELECTRICAL CONTRACTOR WILL BE REQUIRED TO REPAIR OR REPLACE COMPONENTS FOUND TO BE DEFECTIVE. THE ELECTRICAL CONTRACTOR MUST COORDINATE LIGHTING CONTROL START —UP WITH HVAC MANUFACTURER REPRESENTATIVE. FAILURE TO DO SO MAY REQUIRE THE ELECTRICAL CONTRACTOR TO RETURN TO THE JOB SITE TO PERFORM START —UP AT A FUTURE DATE AT THE ELECTRICAL CONTRACTOR'S OWN EXPENSE. TP PENDENT MOUNTED SINGLE CIRCUIT TRACK, MATTE WHITE FINISH CON —TECH: LT2P —LT12P w /LA5012P— LA5118P JUNO: T2WH —T12WH w/T90WH -12 -48 or T91WH -12 -48 }IALO: L650P —L653P w /L992P. L48P INDY: 2T —W — 12T —W w /50T -18W — 48W or 50LE -18W — 48W or 51T -18W — 48W or 51LE -18W - MI 11/16" 120 VOLTS TS SURFACE MOUNTED SINGLE CIRCUIT TRACK, MATTE WHiTE FINISH CON —TECH: LT2P. LT4P. LT6P. LISP. LT12P as required JUNO: T2WH. T4WH. T6WH. TBWH. T12WH as required }HALO: L650P. L651P. L652P. L653P as required INDY: 2T —W. 4T —W. 6T —W. 8T —W. 12T —W as required 11/16" 120 VOLTS X2 SEMI — RECESSED CEILING MOUNTED LED EXIT SIGN, EDGE LIT, SINGLE FACE, INJECTION — MOLDED. WEDGE SHAPED ACRYLIC, RED LETTERS, INTEGRAL EMERGENCY SERVICE HIGH —UTES: LED— BPN— RXFO -2 —RC LED 4 WATTS 120 VOLTS X6 THERMOPLASTIC EXIT SIGN, UNIVERSAL MOUNTING CEIUNG/WALL, 110 LAMPS AND INTEGRAL BATTERY BACK UP FOR 90 MINUTES fSTRAUTE: TPURWEIM LED 4 WATTS 120 VOLTS X9 RECESSED EMERGENCY LIGHT FOR SALES FLOOR USE, ADJUSTABLE LAMP. INTEGRAL BATTERY FOR EMERGENCY OPERATION NIGHUTES: AG -1 -16 UGHTALARMS: 805P1 /LH5 (1) 8W Halogen 8 WATTS 120 VOLTS XA SEMI— RECESSED CEILING MOUNTED EMERGENCY LIGHT FOR SALES FLOOR USE, (2) ADJUSTABLE LAMPS BELOW CEILING LINE, INTEGRAL BATTERY FOR EMERGENCY OPERATION. HIGHUTES: XC —R -05 (2) 4W Halogen 8 WATTS 120 VOLTS NOTES 1. ALL FIXTURES ARE FURNISHED BY ESD &C UNLESS OTHERWISE NOTED. 2. ALL UGHT FIXTURES AND WIRING METHODS WITHIN PLENUM CEILING SHALL BE "PLENUM APPROVED" AS PER LOCAL ORDINANCES. 3. ALL LIGHT FIXTURES WITH 'EM' AFTER FIXTURE DESIGNATION SHALL BE PROVIDED WITH AN EMERGENCY BALLAST, PRODUCING A MINIMUM OF 1000 LUMENS FOR ONE (1) 48" LAMP. L p REVIEWED FOR CODE NW\ 70 CEO City Of 'Tukwila BUILDING DIVISION LIGHTING PLAN CONSTRUCTION NOTES NTS OODE033JONOTE ELECTRICAL LIGHT FIXTURE SCHEDULE NTS N D CO Ln d) Y0000 Q-oo 1- 0 La1 0 11x' O.. 0 0 V1 LLI REVISIONS: REQUIRED BY: RECEIVED CITY OF TI IKVVILA * INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 04/18/2008 AOH AOH RAP ELECTRICAL LIGHTING SCHEDULE DRAWING NUMBER: MOTION SENSOR SWITCH IN RESTROOM FER TO LIGHTING PLAN SHEETS FOR NOTE 1) (NEUTRAL) N 120V (LINE) L RESTROOM EXHAUST FAN G LOAD IFS NOTE: 1" CONDUIT TENANT SPACE FINISH CONDUIT WITH INSULATED BUSHING 1. FURNISH AND INSTALL 1" CONDUIT FROM IFS TO MAIN ENTRANCE OF VSS AND FINISH CONDUIT WITH AN INSULATED BUSHING FOR FUTURE INSTALLATION OF THE TRAFFIC COUNTER. TRAFFIC COUNTER DETAIL NTS OODE041DOXFAN REVII YYED OR COLE COMPLIANCE NFPA 70 ° NEC City Of Tukwila MAY 200E BURDINC DIVISION MAIN ENTRANCE NTS OODE041BOTRAF B 4-Ft- (LINE) 0 120V PRIMARY (NEUTRAL) N 24V SECONDARY TRANSFORMER REAR DOOR PUSHBUTTON AT 48" A.F.F. BUZZER IN "NON- SALES" BUZZER AT BREAK AREA AT 78" A.F.F. "SALES" BUZZER AT CASH WRAP "SALES" BUZZER AT CASH WRAP DELIVERY BUZZER SCHEMATIC NTS OODE041AOBUZZ SHREMSHOCK> 6130 S. WESTERVI 614 -545- GINEERING, INC. ::. ROAD �XPifl p�_ /Co — rc7 j z 0 z z • VU-1 ? !!!!!! w O ° O V l W>.- w » Z Z W '�` 4 f'! 1 a h Z _ _ OOZQ W m x 2 0= z r� =r'zo = zN z !IO Z 3 r 3 0 G 7 ¢ O W Q !! _ W 4 "' it W x r O W S W— N Z U U O O N ce W== 0E,11-0 N N z Q° r= ~ Q°= 0 ¢� Or- U r z4w o ■w O V W w y �__(¢ W�JOZ ("1-.2 W Q'1 =O3 °z Wa�r°— °� -owF-z k "g omN�� zxaj= ow ° =o_ � ° °r��v W d () �-- �U' 4Z z = U r O V) V 7 :-C! m O O w V W = rUWO W W r'w-wi o: O< O _ l Z W J 03 ° VN m - ^JON N Ovl J= Z OtiW jww W f -. _ O F- O Z U t n c c�r�z3� :::::::: w x O Z p N3S� W W Y 7 z �aO �y 0= Q n: Vl O x 0 S a o= O ZZOZ = u 3a,wQ_ p�QpNU VN� V~i mO�(F -jam N O :::::: �W W W O W V x V) r ¢ D: O WZOn. 0_ ° ::::W X Z R r U n. n- w Q ¢ W W , O 0000581 PROJECT INFORMATION: N 0 CO u7 0) CO 00 0 0 t UJ o 00 Z o 0 co W o ✓ >o t= o r J a (n 0 co oo C. I-00 Zci) W J w WN)I= -3 u. 4Ow (/�J Z X Wa °a ov—)o E_Ow UwN V) V) V) CI 1- W w� LLI REVISIONS: REQUIRED 13Y: DATE ��n_vi..i ILLS CITY OR TUKWILA APR 2 9 2008 PERMIT CENTER * INDICATES NO REVISION TO THIS SHEET DATE ISSUED: 04/18/2008 DESIGNED BY: AOH DRAWN BY: AOH CHECKED BY: RAP ELECTRICAL DETAILS DRAWING NUMBER: 1 THIS SHEET IS PART OF THE CONTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY, THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS. THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEERING ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. DREAMSTEAMER "A" 7 - 411E1%/Ar I` La DREAMSTEAMER DREAMSTEAMER ■B" NOTE: CONTRACTOR TO LOCATE OUTLET WHERE MOST ACCESIBLE, BASED ON DETAIL. DREAMSTEAMER OUTLET LOCATION 6-1 -0101- DRAIN (DO NOT CONNECT) SPECIFICATION SERIES 2200 COLUMNS OF QUAD RECEPT'S. THREE PHASE MODEL (208 VOLTS) 2200 -308 MODEL (240 VOLTS) 2200 -340 BRANCH CIRCUIT RATING 30 AMPS RECEPTACLE NEMA CONFIGURATION NEMA L15 -30R CATALOG NO. PASS & SEYMOUR L -15 30R POWER 9,000 WATTS WIDTH 48 INCHES DEPTH 30 1/2 INCHES HEIGHT 88 INCHES WEIGHT (WITH WATER) 300 LBS. WATER CAPACITY (APX.) 7 GALLONS WATER USAGE (APX.) 1/2 GALLONS PER HOUR 18" DREAMSTEAMER DETAIL "c" INDIVIDUAL BRANCH CIRCUIT COLD WATER LINE, REFER TO PLUMBING DRAWINGS FOR DETAIL TWIST LOCK RECEPTACLE 18" A.F.F. FROM CENTER OF THE OUTLET BOX NTS t,Ya 1] :eL Ir$ I•]'];1!, 111 J NO OF WALKIES QUAD RECEPT'S. REQUIRED COLUMNS OF QUAD RECEPT'S. 0 -12 2 1 13 -24 4 2 INSTALL QUAD RECEPTACLES FOR EMPLOYEE WALKIES INTO COLUMNS. THE NUMBER OF RECEPTACLES AND COLUMNS DEPENDS UPON THE NUMBER OF WALKIES. REFER TO SCHEDULE. QUAD RECEPTACLE FOR WALKIES (TYP) SHELVING IN NON -SALES AREA. REFER TO ARCHITECTURAL SHEETS FOR MORE INFORMATION. 1" SECOND COLUMN OF QUAD RECEPTACLES (IF REQUIRED) REFER TO SCHEDULE. 3, -5" 4' -7" EMPLOYEE WALKIE RECEPTACLE DETAIL TO TELCO SECTION OF THE SWITCHGEAR. TO PANEL BOARD SECTION OF THE SWITCHGEAR. CEILING 21 2" SS O O O 0 ELEVATION NTS MANAGER PLAN NTS CODED NOTES NTS 02DE042DOWALK 10 QUAD OUTLET FOR DATA, TELEPHONE, FAX, AND POLLING. ELECTRICAL CONTRACTOR TO RUN A 1" EMPTY CONDUIT, WITH PULLWIRE, BACK TO TELCO SECTION OF THE SWITCHGEAR. DATA /TELEPHONE WIRE AND COVERPLATE BY OTHERS. 02 20 AMP, 120 VOLT SINGLE PHASE ISOLATED DEDICATED CIRCUIT, 20 AMP #166300 -W RECEPTACLE, WITH ISOLATED THIRD WIRE GROUND, IN A SINGLE 3/4" CONDUIT BACK TO PANELBOARD SECTION OF THE SWITCHGEAR FOR COMPUTER TERMINAL DO NOT SHARE ANY PART OF THIS CIRCUIT WITH ANY OTHER BRANCH CIRCUITS. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. 30 20 AMP, 120 VOLT CIRCUIT AND DUPLEX RECEPTACLE FOR UTILITY POWER, IN A SINGLE 3/4" CONDUIT BACK TO PANELBOARD SECTION OF THE SWITCHGEAR. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. 0 20 AMP, 120 VOLT CIRCUIT AND QUAD RECEPTACLE FOR UTILITY POWER, IN A SINGLE 3/4" CONDUIT BACK TO PANELBOARD SECTION OF THE SWITCHGEAR. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. 05 20 AMP, 120 VOLT CIRCUIT AND QUADRUPLEX RECEPTACLE AND DUPLEX RECEPTACLE FOR CCTV SECURITY EQUIPMENT IN A SINGLE 3/4" CONDUIT BACK TO PANELBOARD SECTION OF THE SWITCHGEAR. INSTALL QUAD AT 55" A.F.F. TO MIDDLE OF QUAD. CONNECT TO CIRCUIT SHOWN ON POWER PLAN. D MANAGER'S OFFICE DETAIL (TYPICAL) NTS 02DE042COMNGD C LEAVE 6' -0" OF COILED, TAPED & LABELED SPEAKER WIRING (TYP. EACH CIRCUIT) d J -BOX ABOVE CEILING WITH PULLWIRE 3/4" CONDUIT 1► • ,1 J -BOX IN WALL W/ COVERPLATE MOUNTED AT 80" A.F.F. NEXT TO QUAD RECEPTACLE 14" WALL CLEARANCE ON HINGED SIDE OF CABINET 1'1 TYP. COILED AND TAPED (TYP). 1 0 NON -SALES SOUND SYSTEM CODED NOTES T COAXIAL SPEAKER ENCLOSURE ( #CP87) AND SUPPORTS. LEAVE SLACK SPEAKER WIRE HANG 36" BELOW CEILING LINE. SUB - WOOFER SPEAKER ENCLOSURE ( #DX1312) AND SUPPORTS. LEAVE SLACK SPEAKER WIRE HANG 36" BELOW CEILING LINE. SPEAKER WIRE "WEST PENN" 125224 #18 AWG OR "DECARON" 1P70 118 AWG ONLY. NO SUBSTITUTIONS. RUN WIRE (IN CONDUIT, IF REQUIRED BY LOCAL CODE. SEE ELECTRICAL SPECIFICATIONS FOR EXACT REQUIREMENTS) BETWEEN SPEAKER ENCLOSURES AND TO SYSTEM CABINET LOCATED IN SALES AREA. RUN WIRE IN RELATED CONDUIT AT SOUND SYSTEM CABINET. LABEL AND TAG SPEAKER WIRE HOMERUNS AT SOUND SYSTEM CABINET AS TO AREA SERVED (I.E. SALES COAX, SUB - WOOFER, FITTING ROOM, NON- SALES, ETC.). TYPICAL AS REQUIRED. SOUND SYSTEM CABINET. DWR SERIES 19" SECTIONAL WALL RACK ENCLOSURE, MODEL NO. 24 -22. REFER TO SPECIFICATION. RUN 3/4" CONDUIT TO TELEPHONE BOARD. MUSIC VENDOR WILL RUN (2) PAIR OF #20 AWG SPEAKER WIRE FOR EACH TELEPHONE SYSTEM AS REQUIRED, AND LABEL AND TAG WIRE AT EACH END (THUS: M.O.H. AND TELECO PAGE"). NOTE: REFER TO RESPONSIBILTY SCHEDULE. COAX SUB - WOOFER (2) 1 -1/2" EMT CONDUIT FOR SPEAKER WIRE, RUN INSIDE WALL. TERMINATE IN 6x6x4 BOX INSIDE OPENING. LEAVE 6' -0" OF COILED, TAPED & LABELED SPEAKER WIRING (TYP. EACH CIRCUIT) QUADRAPLEX RECEPTACLE MOUNTED AT 80" A.F.F. TO CENTERLINE OF SOUND SYSTEM CABINET. 36" TYP. SALES DWR SERIES 19" SPECIFICATIONS EIA COMPLIANT 19" WALL -MOUNT RACK SHALL BE MIDDLE ATLANTIC PRODUCTS /DATATEL MODEL IIDWR- 24 -22. PART NUMBER SHALL BE SUFFIXED WITH "PD" TO INDICATE THAT THE RACK SHALL SHIP ASSEMBLED WITH LOCKING PLEXIGLASS DOOR PRE - INSTALLED. OVERALL DIMENSIONS SHALL BE 23.4 "Wx24 "Hx22 "D. WEIGHT CAPACITY SHALL BE 300Ibs. CENTER SECTION AND BACKPAN SHALL BE 16 -GAUGE STEEL, PHOSPHATE PRE - TREATED AND FINISHED IN BLACK POWDER COAT. RACKRAIL SHALL BE CONSTRUCTED OF 11 -GAUGE STEEL WITH TAPPED 1 - -32 MOUNTING HOLES IN UNIVERSAL EIA SPACING WITH BLACK AND COAT FINISH AND MARKED RACKSPACES. RACK SHALL BE CONSTRUCTED TO SWING OPEN FOR COMPONENT CABLING ACCESS, CENTER SECTION SHALL PIVOT FOR EITHER LEFT OR RIGHT OPENING. BACKPAN SHALL BE FITTED WITH FACTORY INSTALLED LOCK AND LATCH CAPABLE OF ACCEPTING PADLOCK. RACK SHALL HAVE A REMOVABLE KNOCKOUT PANEL WITH 1/2 ", 3/4 ", AND 1 -1/2" ELECTRICAL KNOCKOUTS INSTALLED IN BOTTOM OF BACKPAN, AND A REMOVABLE REAR KNOCKOUT PANEL WITH 1/2 ", 3/4 ", 1" AND 1 -1/2" ELECTRICAL KNOCKOUTS, AND BNC KNOCKOUTS FOR UHF /VHF ANTENNAS INSTALLED IN TOP OF BACKPAN. LARGE LASER KNOCKOUT ON BACKPAN SHALL HAVE A 12 -1/2 "x12 -1/2" OPENING FOR CABLE PASS - THROUGH. FAN KNOCKOUTS ON TOP AND BOTTOM SHALL ALLOW FOR INSTALLATION OF UP TO FOUR 4 -1/2" FANS. TOP, BOTTOM AND SIDES SHALL FEATURE VERTICAL VENT PATTERN. RACK SHALL BE UL LISTED IN THE US AND CANADA. REVIEWED FOR CODE COMPLIANCE NFPA 70 °- NEC EIA 2u03 City Of Tukwila BUILDING NISI (JBL -RACK) SOUND SYSTEM INSTALLATION DETAIL NTS oiJiiti. *1iL'l A G_ I•NEERING, INC. AD 11 4 43▪ 084 '?;S70NAL E E12 3 o z O 2 Z O H :1 O W W Ii QN a Z W U W N - O O W O p. oozy • °N3a oow m::: V l x V d ~ O 0 � o z r :- z c 4'14 z Z 0 w Z3,__3• w co�oQ Li0• L) • J W x H O W W W • m x W 3 O U O° N NO°- O N� W =C O'/1U�� [W/11 QZ;LI! O= •<2:: ��zaWo �o_ N Q Z w C J O Z N a W W= m = Q V° ° ,- o w �- Z x W z °� oWtio Q���Zo m Z 0 ° x C O Lz a O x �CaO N Q a z c� > :f _ W L-iO"- T =0p W °V Z, O V N UU N0 O~ Uw O W w!• = • O X • W g. N _Z W d' Q Z Q1• 6- Z Q Z Q ~_ w � f-w 3• ^ • Q�ci�W • t W • ~ ?° ° • Z x W U Q D W W 4�,QW Z Qom ~ ~�O z °'- ° a �. il 3' Q J O Z Z W Z O 0 Z° Z; Z C7 �(~j0 y O O -V- ('/La 1W-- YW Z i:2)1 W W • W O W • U • W B O O O W LY W O W O W Z 0 2 0° W >-- d H W 2 d W U O J L OLr W X Z xZ W �dH O= Q p.0 �F --U• LLK W Q H QlY Q • NO U_ .--Z W J 0000581 INFORMATION: N 000 LC) CD CD CD y 00 00 o 4 H Z U 0 W,.=O < 0- Y W < w 0- < REVISIONS: REQUIRED BY: DATE RtCddtD CITY OF TUKWILA APR 2 9 2008 PERMIT CPI .IrrR + INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 04/18/2008 AOH EDS RAP ELECTRICAL DETAILS DRAWING NUMBER: 4. ExPIRES (--[ , -/o 1 I F-1 CONDUIT STUB -UPS d d b 0 3" 0.C. CASHWRAP BACK ELEVATION NTS (1 0 0 0 0 CABLE MGMT thk MI II o -6" 2' -2" ACCESS PANEL (TYP.) CASHWRAP- REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE AND ASSOCIATE FACE OF CASHWRAP IN ORDER TO LOCATE STUB -UPS CONNECT TO CIRCUIT SHOWN ON POWER PLAN O CASHWRAP /BACKWRAP PLAN NTS -9 1/8" CONNECT TO CIRCUIT SHOWN ON POWER PLAN 2' -4 1/8" m m m 1 BACKWRAP FRONT ELEVATION NTS 2' -4 1/8" 2' -9 1/8' �-.- " - REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE CASHWRAP COUNTER DETAIL EXPRESS 4 REGISTER CASHWRAP (STRAIGHT) CASHWRAP CODED NOTES 0 REGISTERS SHALL SHARE A 20 AMP, 120 VOLT DEDICATED CIRCUIT WITH A SEPARATE ISOLATED NEUTRAL & 3RD WIRE GROUND. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. THE ELECTRICAL CONTRACTOR SHALL FURNISH ORANGE #IG5362 RECEPTACLES (HUBBELL). CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP INSIDE WALL TO CEILING SPACE AND CONNECT TO PANEL LOCATED INSIDE IFS ENCLOSURE. REFER TO POWER PLAN AND PANEL SCHEDULES FOR CIRCUIT DESIGNATIONS. 02 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /DUPLEX RECEPTACLE. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE UP INSIDE WALL TO CEILING SPACE AND BACK TO PANEL AS INDICATED ON POWER PLAN. 03 STUB UP 1" CONDUIT 1" (A.F.F.). INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO 4X4 J -BOX FOR DATA AND TELEPHONE. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP IN WALL TO CEILING SPACE AND CONNECT TO TELECO STRUCTURE PORTION OF THE IFS SWITCHGEAR. WIRE FOR DATA LINES TO BE PULLED AND CONNECTED BY P.O.S. CONTRACTOR. ® 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /QUAD RECEPTACLE BY ELECTRICAL CONTRACTOR. CONNECT TO CIRCUIT AS SHOWN ON POWER PLAN. ® TELEPHONE OUTLET ON INSIDE OF BACKWRAP UNIT. SEE NOTE (6). TELEPHONE WIRE AND #RJ14C JACK BY OTHERS. ® 3/4" TELEPHONE CONDUIT WITH PULLWIRE TO TELEPHONE BOARD BY ELECTRICAL CONTRACTOR. #RJ14C JACK ON LINES #1 AND #2 FOR TELEPHONE BY OTHERS. 07 EDWARDS 1064 -G5 BUZZER. SEE POWER PLAN FOR ADDITIONAL INFORMATION. GENERAL NOTES 1. RUN METAL CLAD (MC) CABLE TO EACH RECEPTACLE FROM J -BOXES THRU WIREWAY WITHIN CASHWRAP COUNTER. 2. WIRING FROM CONDUIT STUB -UPS TO J -BOXES ARE TO BE RUN IN FLEXIBLE METAL CONDUIT. 3. LABEL AND TAG ALL PULLWIRE RUNS AT EACH END WITH ORIGIN /DESIGNATION. 4. DATA TERMINALS AND CONNECTIONS BY P.O.S. CONTRACTOR. 5. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. 4 REG. CASHWRAP /BACKWRAP DETAIL NTS t•E P7IePrkL! ►C•'►l N 0 0 0 0 1111- TT CABLE MG u CI CONDUIT STUB -UPC O.C. III d b b CASHWRAP BACK ELEVATION NTS L.- . 2' -6" n- - 2' -1 7/8" 0 0 kn CONNECT TO CIRCUIT 51-1OWN ON POWER PLAN ACCESS PANEL (TYP.) 0 REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE AND ASSOCIATE SIDE FACE OF CASHWRAP IN ORDER TO LOCATE STUB -UPS CASHWRAP /BACKWRAP PLAN NTS 1'-1" BACK WALL/ CONNECT TO CIRCUIT SHOWN ON POWER PLAN BACKWRAP FRONT ELEVATION NTS 1' -1" REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE CASHWRAP COUNTER DETAIL EXPRESS 2 REGISTER CASHWRAP (STRAIGHT) CASHWRAP CODED NOTES 0 REGISTERS SHALL SHARE A 20 AMP, 120 VOLT DEDICATED CIRCUIT WITH A SEPARATE ISOLATED NEUTRAL & 3RD WIRE GROUND. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. THE ELECTRICAL CONTRACTOR SHALL FURNISH ORANGE #IG5362 RECEPTACLES (HUBBELL). CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP INSIDE WALL TO CEILING SPACE AND CONNECT TO PANEL LOCATED INSIDE IFS ENCLOSURE. REFER TO POWER PLAN AND PANEL SCHEDULES FOR CIRCUIT DESIGNATIONS. 0 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /DUPLEX RECEPTACLE. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE UP INSIDE WALL TO CEILING SPACE AND BACK TO PANEL AS INDICATED ON POWER PLAN. ® STUB UP 1" CONDUIT 1" (A.F.F.). INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO 4X4 J -BOX FOR DATA AND TELEPHONE. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP IN WALL TO CEILING SPACE AND CONNECT TO TELECO STRUCTURE PORTION OF THE IFS SWITCHGEAR. WIRE FOR DATA LINES TO BE PULLED AND CONNECTED BY P.O.S. CONTRACTOR. ® 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /QUAD RECEPTACLE BY ELECTRICAL CONTRACTOR. CONNECT TO CIRCUIT AS SHOWN ON POWER PLAN. 05 TELEPHONE OUTLET ON INSIDE OF BACKWRAP UNIT. SEE NOTE (6). TELEPHONE WIRE AND #RJ14C JACK BY OTHERS. ® 3/4" TELEPHONE CONDUIT WITH PULLWIRE TO TELEPHONE BOARD BY ELECTRICAL CONTRACTOR. #RJ14C JACK ON LINES #1 AND #2 FOR TELEPHONE BY OTHERS. 70 EDWARDS 1064 -G5 BUZZER. SEE POWER PLAN FOR ADDITIONAL INFORMATION. GENERAL NOTES 1. RUN METAL CLAD (MC) CABLE TO EACH RECEPTACLE FROM J -BOXES THRU WIREWAY WITHIN CASHWRAP COUNTER. 2. WIRING FROM CONDUIT STUB -UPS TO J -BOXES ARE TO BE RUN IN FLEXIBLE METAL CONDUIT. 3. LABEL AND TAG ALL PULLWIRE RUNS AT EACH END WITH ORIGIN /DESIGNATION. 4. DATA TERMINALS AND CONNECTIONS BY P.O.S. CONTRACTOR. 5. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. FRONT ELEVATION NTS NO METAL REBAR OR WIRE MESH WITHIN 8" OF BOTTOM AND 12" OF SIDES OF ANTENNA (K) POWER PACK • - e -,r7r w -1T- -e C- IF it - a -6 % d a- -a STORE SIDE (P) ANTENNAS 0 00 0 0 0 EMOTE ALARM CEILING LINE REBAR, MESH, PAN OR OTHER METAL REINFORCEMENT CONDUIT RUN 35' OR 55' MAX. CAP BOARD ENCLOSURE DESCRIPTION DIMENSIONS (A) 1 1 jo - -- �mom�� (N) ■��� � (H) DEPTH OF EXCAVATION 2" MIN. TO 2.75" MAX. ra---J U El Wi U 8" MIN. (F) CAP BOX TO POWER PACK 7' MAX. (G) POWER PACK TO REMOTE ALARM 25' MAX. (H) ANTENNA SEPERATION 2" MIN., 24" MAX. (J) OUTER CONDUIT TO ANTENNA 10" MIN. •' I-I- 4' -3" (L) I F-1 CONDUIT STUB -UPS d d b 0 3" 0.C. CASHWRAP BACK ELEVATION NTS (1 0 0 0 0 CABLE MGMT thk MI II o -6" 2' -2" ACCESS PANEL (TYP.) CASHWRAP- REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE AND ASSOCIATE FACE OF CASHWRAP IN ORDER TO LOCATE STUB -UPS CONNECT TO CIRCUIT SHOWN ON POWER PLAN O CASHWRAP /BACKWRAP PLAN NTS -9 1/8" CONNECT TO CIRCUIT SHOWN ON POWER PLAN 2' -4 1/8" m m m 1 BACKWRAP FRONT ELEVATION NTS 2' -4 1/8" 2' -9 1/8' �-.- " - REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE CASHWRAP COUNTER DETAIL EXPRESS 4 REGISTER CASHWRAP (STRAIGHT) CASHWRAP CODED NOTES 0 REGISTERS SHALL SHARE A 20 AMP, 120 VOLT DEDICATED CIRCUIT WITH A SEPARATE ISOLATED NEUTRAL & 3RD WIRE GROUND. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. THE ELECTRICAL CONTRACTOR SHALL FURNISH ORANGE #IG5362 RECEPTACLES (HUBBELL). CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP INSIDE WALL TO CEILING SPACE AND CONNECT TO PANEL LOCATED INSIDE IFS ENCLOSURE. REFER TO POWER PLAN AND PANEL SCHEDULES FOR CIRCUIT DESIGNATIONS. 02 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /DUPLEX RECEPTACLE. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE UP INSIDE WALL TO CEILING SPACE AND BACK TO PANEL AS INDICATED ON POWER PLAN. 03 STUB UP 1" CONDUIT 1" (A.F.F.). INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO 4X4 J -BOX FOR DATA AND TELEPHONE. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP IN WALL TO CEILING SPACE AND CONNECT TO TELECO STRUCTURE PORTION OF THE IFS SWITCHGEAR. WIRE FOR DATA LINES TO BE PULLED AND CONNECTED BY P.O.S. CONTRACTOR. ® 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /QUAD RECEPTACLE BY ELECTRICAL CONTRACTOR. CONNECT TO CIRCUIT AS SHOWN ON POWER PLAN. ® TELEPHONE OUTLET ON INSIDE OF BACKWRAP UNIT. SEE NOTE (6). TELEPHONE WIRE AND #RJ14C JACK BY OTHERS. ® 3/4" TELEPHONE CONDUIT WITH PULLWIRE TO TELEPHONE BOARD BY ELECTRICAL CONTRACTOR. #RJ14C JACK ON LINES #1 AND #2 FOR TELEPHONE BY OTHERS. 07 EDWARDS 1064 -G5 BUZZER. SEE POWER PLAN FOR ADDITIONAL INFORMATION. GENERAL NOTES 1. RUN METAL CLAD (MC) CABLE TO EACH RECEPTACLE FROM J -BOXES THRU WIREWAY WITHIN CASHWRAP COUNTER. 2. WIRING FROM CONDUIT STUB -UPS TO J -BOXES ARE TO BE RUN IN FLEXIBLE METAL CONDUIT. 3. LABEL AND TAG ALL PULLWIRE RUNS AT EACH END WITH ORIGIN /DESIGNATION. 4. DATA TERMINALS AND CONNECTIONS BY P.O.S. CONTRACTOR. 5. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. 4 REG. CASHWRAP /BACKWRAP DETAIL NTS t•E P7IePrkL! ►C•'►l N 0 0 0 0 1111- TT CABLE MG u CI CONDUIT STUB -UPC O.C. III d b b CASHWRAP BACK ELEVATION NTS L.- . 2' -6" n- - 2' -1 7/8" 0 0 kn CONNECT TO CIRCUIT 51-1OWN ON POWER PLAN ACCESS PANEL (TYP.) 0 REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE AND ASSOCIATE SIDE FACE OF CASHWRAP IN ORDER TO LOCATE STUB -UPS CASHWRAP /BACKWRAP PLAN NTS 1'-1" BACK WALL/ CONNECT TO CIRCUIT SHOWN ON POWER PLAN BACKWRAP FRONT ELEVATION NTS 1' -1" REFER TO ARCHITECT PLAN FOR LOCATION OF CENTERLINE CASHWRAP COUNTER DETAIL EXPRESS 2 REGISTER CASHWRAP (STRAIGHT) CASHWRAP CODED NOTES 0 REGISTERS SHALL SHARE A 20 AMP, 120 VOLT DEDICATED CIRCUIT WITH A SEPARATE ISOLATED NEUTRAL & 3RD WIRE GROUND. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. THE ELECTRICAL CONTRACTOR SHALL FURNISH ORANGE #IG5362 RECEPTACLES (HUBBELL). CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP INSIDE WALL TO CEILING SPACE AND CONNECT TO PANEL LOCATED INSIDE IFS ENCLOSURE. REFER TO POWER PLAN AND PANEL SCHEDULES FOR CIRCUIT DESIGNATIONS. 0 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /DUPLEX RECEPTACLE. STUB UP 3/4" CONDUIT 1" (A.F.F.) WHERE SHOWN ON DETAIL. INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO J -BOX AND CONNECT TO DUPLEX RECEPTACLES. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE UP INSIDE WALL TO CEILING SPACE AND BACK TO PANEL AS INDICATED ON POWER PLAN. ® STUB UP 1" CONDUIT 1" (A.F.F.). INSTALL FLEXIBLE METAL CONDUIT FROM STUB -UP TO 4X4 J -BOX FOR DATA AND TELEPHONE. CUT AND PATCH FLOOR AS REQUIRED TO ROUTE CONDUIT TO WALL AS SHOWN. ROUTE UP IN WALL TO CEILING SPACE AND CONNECT TO TELECO STRUCTURE PORTION OF THE IFS SWITCHGEAR. WIRE FOR DATA LINES TO BE PULLED AND CONNECTED BY P.O.S. CONTRACTOR. ® 20 AMP, 120V, CIRCUIT FOR UTILITY POWER W /QUAD RECEPTACLE BY ELECTRICAL CONTRACTOR. CONNECT TO CIRCUIT AS SHOWN ON POWER PLAN. 05 TELEPHONE OUTLET ON INSIDE OF BACKWRAP UNIT. SEE NOTE (6). TELEPHONE WIRE AND #RJ14C JACK BY OTHERS. ® 3/4" TELEPHONE CONDUIT WITH PULLWIRE TO TELEPHONE BOARD BY ELECTRICAL CONTRACTOR. #RJ14C JACK ON LINES #1 AND #2 FOR TELEPHONE BY OTHERS. 70 EDWARDS 1064 -G5 BUZZER. SEE POWER PLAN FOR ADDITIONAL INFORMATION. GENERAL NOTES 1. RUN METAL CLAD (MC) CABLE TO EACH RECEPTACLE FROM J -BOXES THRU WIREWAY WITHIN CASHWRAP COUNTER. 2. WIRING FROM CONDUIT STUB -UPS TO J -BOXES ARE TO BE RUN IN FLEXIBLE METAL CONDUIT. 3. LABEL AND TAG ALL PULLWIRE RUNS AT EACH END WITH ORIGIN /DESIGNATION. 4. DATA TERMINALS AND CONNECTIONS BY P.O.S. CONTRACTOR. 5. REFER TO ARCHITECTURAL SHEETS FOR ADDITIONAL INFORMATION. FRONT ELEVATION NTS NO METAL REBAR OR WIRE MESH WITHIN 8" OF BOTTOM AND 12" OF SIDES OF ANTENNA (K) POWER PACK • - e -,r7r w -1T- -e C- IF it - a -6 % d a- -a STORE SIDE (P) ANTENNAS 0 00 0 0 0 EMOTE ALARM CEILING LINE REBAR, MESH, PAN OR OTHER METAL REINFORCEMENT CONDUIT RUN 35' OR 55' MAX. CAP BOARD ENCLOSURE PLAN VIEW NTS MALL SIDE LEASE LINE (FIELD VERIFY) CENTERLINE OF GRILLE SENSORMATIC DIGITAL FLOOR MAX SYSTEM NOTES REMOTE ALARM POWER PACK O INDIVIDUAL 3/4 INCH CONDUIT INTERCONNECTS BETWEEN EACH FLOOR PANEL AND ITS RESPECTIVE CAP ENCLOSURE BOX - CAP ENCLOSURE BOXES ARE LOCATED ABOVE CEILING WITHIN 2 FEET OF POWER PACK. CONDUIT ABOVE CEILING SHALL BE ROUTED CLEAR OF ACCESS OPENING. MAXIMUM LENGTH OF CONDUIT SHALL NOT EXCEED 35' FROM FLOOR PANEL TO CAP BOX. NOTE: CONDUIT RUNS UNDERFLOOR SHALL BE RMC OR IMC. 0 CAP BOARD ENCLOSURE. EACH CAP BOX MUST BE MOUNTED WITHIN 2 FEET OF POWER PACK. ® DUPLEX RECEPTACLE BOX LOCATED IN AREA ABOVE CEILING. ELECTRICAL REQUIREMENTS ARE 120V. AC, THREE WIRE, DEDICATED CIRCUIT, 24 HOUR CIRCUIT WITH LESS THAN 0.5V. AC BETWEEN NEUTRAL AND ISOLATED GROUND. RECEPTACLE SHALL BE INSTALLED WITHIN 2' -0" OF POWER PACK. INSTALLATION OF POWER PACK AND PLUG IN OF POWER PACKS TO RECEPTACLE TO BE BY SENSORMATIC. ® RETURN AIR GRILLE OR ACCESS PANEL TO BE USED FOR SERVICING OF EQUIPMENT LOCATED ABOVE CEILING. COORDINATE ROUGH -IN OF JUNCTION BOX AND RECEPTACLE WITH THE GENERAL CONTRACTOR. REFER TO MECHANICAL PLANS FOR SIZE OF ACCESS PANEL /GRILLE. 05 1 -1/2 INCHES DEEP X 4 FOOT WIDE (APPROXIMATE) SAWCUT FOR EACH FLOOR PANEL. DEPTH OF CUT SHALL BE LEVEL THROUGHOUT. CONFIRM ACTUAL DIMENSIONS OF SAWCUTS WITH MANUFACTURER'S INSTRUCTIONS. IF THE SLAB CANNOT BE CUT FOR THE INSTALLATION OF THE FLOOR (ANTENNA) PANELS, THE GENERAL CONTRACTOR MUST INVESTIGATE THE OPTION OF "FLOATING" THE PANELS IN AN ADDITIONAL LAYER OF POURED CONCRETE ('RAMPING UP'). THIS WILL DEPEND ON THE LEVEL OF THE FLOOR INSIDE THE STORE IN RELATION TO THE LEVEL OF THE FLOOR IN THE MALL. THE TYPE OF FINISHED FLOORING WILL HAVE SOME EFFECT ON THE ACTUAL DEPTH OF THE FLOOR PANELS IN THE SLAB. THE THICKNESS OF THE FLOORING PLUS THE THICKNESS OF THE CONCRETE PATCH OVER THE PANELS SHOULD BE APPROXIMATELY 1 -1/2 INCHES. © SAWCUT FLOOR 1" WIDE X 1 -1/2" DEEP FOR INSTALLATION OF 3/4" CONDUIT. Q NOTCH TRENCHES AT CONNECTOR LOCATIONS OF FLOOR PANELS. TYPICAL OF ALL FLOOR PANELS. ® NEMA 1 ENCLOSURE SIZED PER N.E.C. TO ENCLOSE DUPLEX RECEPTACLE ABOVE CEILING. NOTE: CONTRACTOR MUST VERIFY AN UNOBSTRUCTED MINIMUM FREE AREA OF 3 FEET VERTICALLY AND 3 FEET WIDE IN EVERY DIRECTION ABOVE THE ACCESS PANEL TO ALLOW FOR INSTALLATION OF THE SENSORMATIC POWER PACK AND CAP ENCLOSURE BOXES. IF FREE AREA CANNOT BE OBTAINED IN THIS LOCATION, IMMEDIATELY CONTACT THE LSD &C PROJECT MANAGER FOR FURTHER INSTALLATION INSTRUCTIONS. NOTE: GENERAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE SENSORMATIC SYSTEM WITH SENSORMATIC MANUFACTURER SPECIFICATIONS. NOTE: INSTALL ANTENNAS EITHER INSIDE THE STORE OR INSIDE THE PORTAL OPENING BASED ON THE TABLE BELOW: PORTAL WIDTH ANTENNA LOCATION 5'- 10.4" TO 7' -10.4" 7'- 10.4" TO 10'- 10.8" 10' -10.8" TO 14' -8.8" 14' -8.8" TO 15' -11.2" 15'- 11.2" 10 28' -5.6" INSIDE PORTAL INSIDE STORE INSIDE PORTAL INSIDE STORE INSIDE PORTAL NOTE DESCRIPTION DIMENSIONS (A) 1 1 (B) - -- (C) (N) 8" MIN. (UNLESS USING SHIELDS UNDER ANTENNA) (H) DEPTH OF EXCAVATION 2" MIN. TO 2.75" MAX. -.. - -,.._. (L) _.-- (M) 8" MIN. (F) CAP BOX TO POWER PACK 7' MAX. (G) PLAN VIEW NTS MALL SIDE LEASE LINE (FIELD VERIFY) CENTERLINE OF GRILLE SENSORMATIC DIGITAL FLOOR MAX SYSTEM NOTES REMOTE ALARM POWER PACK O INDIVIDUAL 3/4 INCH CONDUIT INTERCONNECTS BETWEEN EACH FLOOR PANEL AND ITS RESPECTIVE CAP ENCLOSURE BOX - CAP ENCLOSURE BOXES ARE LOCATED ABOVE CEILING WITHIN 2 FEET OF POWER PACK. CONDUIT ABOVE CEILING SHALL BE ROUTED CLEAR OF ACCESS OPENING. MAXIMUM LENGTH OF CONDUIT SHALL NOT EXCEED 35' FROM FLOOR PANEL TO CAP BOX. NOTE: CONDUIT RUNS UNDERFLOOR SHALL BE RMC OR IMC. 0 CAP BOARD ENCLOSURE. EACH CAP BOX MUST BE MOUNTED WITHIN 2 FEET OF POWER PACK. ® DUPLEX RECEPTACLE BOX LOCATED IN AREA ABOVE CEILING. ELECTRICAL REQUIREMENTS ARE 120V. AC, THREE WIRE, DEDICATED CIRCUIT, 24 HOUR CIRCUIT WITH LESS THAN 0.5V. AC BETWEEN NEUTRAL AND ISOLATED GROUND. RECEPTACLE SHALL BE INSTALLED WITHIN 2' -0" OF POWER PACK. INSTALLATION OF POWER PACK AND PLUG IN OF POWER PACKS TO RECEPTACLE TO BE BY SENSORMATIC. ® RETURN AIR GRILLE OR ACCESS PANEL TO BE USED FOR SERVICING OF EQUIPMENT LOCATED ABOVE CEILING. COORDINATE ROUGH -IN OF JUNCTION BOX AND RECEPTACLE WITH THE GENERAL CONTRACTOR. REFER TO MECHANICAL PLANS FOR SIZE OF ACCESS PANEL /GRILLE. 05 1 -1/2 INCHES DEEP X 4 FOOT WIDE (APPROXIMATE) SAWCUT FOR EACH FLOOR PANEL. DEPTH OF CUT SHALL BE LEVEL THROUGHOUT. CONFIRM ACTUAL DIMENSIONS OF SAWCUTS WITH MANUFACTURER'S INSTRUCTIONS. IF THE SLAB CANNOT BE CUT FOR THE INSTALLATION OF THE FLOOR (ANTENNA) PANELS, THE GENERAL CONTRACTOR MUST INVESTIGATE THE OPTION OF "FLOATING" THE PANELS IN AN ADDITIONAL LAYER OF POURED CONCRETE ('RAMPING UP'). THIS WILL DEPEND ON THE LEVEL OF THE FLOOR INSIDE THE STORE IN RELATION TO THE LEVEL OF THE FLOOR IN THE MALL. THE TYPE OF FINISHED FLOORING WILL HAVE SOME EFFECT ON THE ACTUAL DEPTH OF THE FLOOR PANELS IN THE SLAB. THE THICKNESS OF THE FLOORING PLUS THE THICKNESS OF THE CONCRETE PATCH OVER THE PANELS SHOULD BE APPROXIMATELY 1 -1/2 INCHES. © SAWCUT FLOOR 1" WIDE X 1 -1/2" DEEP FOR INSTALLATION OF 3/4" CONDUIT. Q NOTCH TRENCHES AT CONNECTOR LOCATIONS OF FLOOR PANELS. TYPICAL OF ALL FLOOR PANELS. ® NEMA 1 ENCLOSURE SIZED PER N.E.C. TO ENCLOSE DUPLEX RECEPTACLE ABOVE CEILING. NOTE: CONTRACTOR MUST VERIFY AN UNOBSTRUCTED MINIMUM FREE AREA OF 3 FEET VERTICALLY AND 3 FEET WIDE IN EVERY DIRECTION ABOVE THE ACCESS PANEL TO ALLOW FOR INSTALLATION OF THE SENSORMATIC POWER PACK AND CAP ENCLOSURE BOXES. IF FREE AREA CANNOT BE OBTAINED IN THIS LOCATION, IMMEDIATELY CONTACT THE LSD &C PROJECT MANAGER FOR FURTHER INSTALLATION INSTRUCTIONS. NOTE: GENERAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF THE SENSORMATIC SYSTEM WITH SENSORMATIC MANUFACTURER SPECIFICATIONS. NOTE: INSTALL ANTENNAS EITHER INSIDE THE STORE OR INSIDE THE PORTAL OPENING BASED ON THE TABLE BELOW: PORTAL WIDTH ANTENNA LOCATION 5'- 10.4" TO 7' -10.4" 7'- 10.4" TO 10'- 10.8" 10' -10.8" TO 14' -8.8" 14' -8.8" TO 15' -11.2" 15'- 11.2" 10 28' -5.6" INSIDE PORTAL INSIDE STORE INSIDE PORTAL INSIDE STORE INSIDE PORTAL NOTE DESCRIPTION DIMENSIONS (A) SURFACE TO ANTENNA 1.25" MIN., 2" MAX. (B) ANTENNA THICKNESS 0.75" (C) ANTENNA TO REBAR 8" MIN. (UNLESS USING SHIELDS UNDER ANTENNA) (D) DEPTH OF EXCAVATION 2" MIN. TO 2.75" MAX. (E) INNER CONDUIT TO ANTENNA 8" MIN. (F) CAP BOX TO POWER PACK 7' MAX. (G) POWER PACK TO REMOTE ALARM 25' MAX. (H) ANTENNA SEPERATION 2" MIN., 24" MAX. (J) OUTER CONDUIT TO ANTENNA 10" MIN. (K) WIDTH OF EXCAVATION 4' -3" (L) WIDTH OF ANTENNA 4'- 10.4" (M) ANTENNA TO LEASE LINE 1" MIN. (N) ANTENNA TO PORTAL LEG 6" MIN., 18" MAX. (0) ANTENNA TO CENTERLINE GRILLE 6.5" MIN. NOTE NO OF ANTENNAS LENGTH OF EXCAVATION (P) 1 5'- 10.4" MIN., 7'- 10.4" MAX. 2 10'- 10.8" MIN., 14' -8.8" MAX. 3 15'- 11.2" MIN., 21' -7.2" MAX. 4 20'- 11.6" MIN., 28' -5.6" MAX. NO OF ANTENNAS POWER PACK(S) REQUIRED CAP ENCLOSURE(S) REQUIRED 1 1 1 2 1 1 3 1 2 4 1 2 2 REG. CASHWRAP /BACKWRAP DETAIL NTS J "ON GRADE" SENSORMATIC (IN STORE) NTS E THIS SHEET IS PART OF THE CONTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY, THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS. THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEERING ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. SHREMSHOCK. 6130 S. WESTERVI 614- 545 GINEERING, INC. AD "F-72 Yoe z 0 z z - J UJ O CO I- Q CO c/a co a. C/) X td W � CC 0000581 INFORMATION: H W CZ 0 /0- o w V/ •- VI N a 00 in rn o 00 00 0- 1- Z U 0 CD et Et NG W Q w \ O CD Q II 00 O O co } Q 0 o = 0 O CL 0 I- a. Z ▪ 0 OS O N C] ow REVISIONS: REQUIRED BY: DATE RECEIVED CITY OF 1 UKWILA APR L 91000 PERMIT CENTER INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 04/18/2008 AOH A0 H RAP ELECTRICAL DETAILS DRAWING NUMBER: ELECTRICAL LOAD SUMMARY SUPPL80V, 30, 4W, 60HZ PANELBOARD A ACTUAL LOCATION : WR ENCLOSURE (IFS) ACTUAL N.E.C. N.E.C. N.E.C. DESCRIPTION CONNECTED POWER FACTOR DEMAND CONNECTED DEMAND DEMAND DESCRIPTION KW /KVA POLE KVA KW /KVA FACTOR KVA LIGHTING 6.566 1.0 6.566 6.566 1.25 8.208 TRACK LIGHTING 17.673 1.0 17.673 23.550 (312 FT) * 29.438 *0.150 SHOW WINDOW 3.675 1.0 3.675 4.800 (24.00' X 0.200) 6.000 LIGHTING ALLOWANCE 9.360 500 1000 9.360 9.360 0 0 9.360 RECEPTACLES 9.360 1.0 9.360 9.360 0.5 1.0 < 10KW REMAINING KW 9.360 MOTORS 40.929 1.0 40.929 40.929 1.0 40.929 FIXED ELECTRIC SPACE HEATING * 59.111 1.0 * 59.111* 59.111* 59.111 1.0 59.111* AIR CONDITIONING 3.000 1.0 0.000* 0.000* 1.25 * * ** 0.000* SYSTEM 0.000* 1.0 3000 1500 D 7 SALES AREA PERIMETER LIGHTS ELECTRIC WATER HEATER 3.000 1.0 3.000 3.000 1.25 3.000 MISCELLANEOUS 23.460 1.0 23.460 23.460 1.0 23.460 TOTAL 163.770 SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. 163.770 170.780 9 179.510 NOTES 1200 1575 * USE GREATER VALUE OF THE TWO CATEGORIES ** N.E.C. ARTICLE 220 -12 REQUIREMENT (200VA PER FOOT OF SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. * ** N.E.C. ARTICLE 220 -12 REQUIREMENT - THE GREATER OF (150VA PER 2 FOOT OF TRACK LIGHTING) OR ACTUAL INSTALLED TRACK LIGHTING VA. * * ** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. N.E.C. DEMAND KVA x 1000 = MINIMUM FEEDER AMPERAGE SYSTEM VOLTAGE x 12 179.510 X 1000 = 216 AMPS NEW 300 AMP SERVICE 480 x 1.73 ENTRY /SHOW WINDOW LIGHTS VOLTAGE : 120/208V, 30, 4W MOUNTING - BUS RATING : 225A PANELBOARD A MAIN CIRCUIT BREAKER • 100 A 5 000 A.I.C. SERIES RATED (SSE SERIES RATED NOTES) LOCATION : WR ENCLOSURE (IFS) LCL LTG ZONE CIR. NO. N.E.C. CB LOAD CB DESCRIPTION CIR. NO. LTG. ZONE LCL DESCRIPTION AMP POLE A B C AMP POLE * 1.0 1 EXIT /EMERGENCY LIGHTS 20 1 344 1134 360 800 1,0 20 1 STOCKROOM LIGHTS /FAN 2 B * 3.675 1.0 3.675 3 3 SPARE 4, 1 9.360 500 1000 9.360 9.360 0 0 9.360 MOTORS SECURITY SYSTEM 4 0.000 SPARE 4 C 5 DREAMSTEAMER O 30 3 D 5 SALES AREA PERIMETER LIGHTS AIR CONDITIONING SYSTEM 0.000* 1.0 0.000 * WALKIE RECEPTACLES 6 760 1052 ELECTRIC WATER HEATER 3.000 1.0 7 FITTING ROOM LIGHTS 6 C MISCELLANEOUS 23.460 1.0 3000 1500 D 7 SALES AREA PERIMETER LIGHTS 2 O WATER HEATER 8 63.734 724 0 79.466 9 ' SPARE 8 C 30001500 ** N.E.C. ARTICLE 220 -12 REQUIREMENT - (200VA PER FOOT OF SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. i A 9 SIGN 10 1200 1575 11 STOCKROOM RECEPTACLES 20 1 SALES AREA TRACK LIGHTS 10 C 1 ELECTRIC WATER COOLER 12 A 11 ENTRY /SHOW WINDOW LIGHTS 13 STOCKROOM RECEPTACLES 1275 1060 SALES AREA NIGHT LIGHTS 12 SPARE 14 13 SALES AREA NIGHT LIGHTS 985 940 800 9QQ SALES AREA TRACK LIGHTS 14 C 17 MICROWAVE 15 SPARE 1200 500 O 1 275 FIRE ALARM CONTROL PANEL 18 SALES AREA TRACK LIGHTS 16 C 19 REFRIGERATOR A 17 SIGN 1200 1080 1200/ 1710 SALES AREA RECEPTACLE 20 SALES AREA TRACK LIGHTS 18 C SPARE 19 SALES AREA NIGHT LIGHTS 1515 1770 SALES AREA RECEPTACLE 22 SALES AREA TRACK LIGHTS 20 C A 21 SIGN SALES AREA RECEPTACLE 24 1200 1210 25 SPARE SALES AREA TRACK LIGHTS 22 C °720 23 SPARE SALES AREA RECEPTACLE 26 0 0 27 SPARE SPARE 24 C O 1260 25 SPARE 28 • 0 119 6 29 SENSORMATIC, I.G. SALES AREA TRACK LIGHTS 26 C D 27 SALES AREA PERIMETER LIGHTS 31 CASHWRAP REGISTER, I.G. 690 945 720 01440 SALES AREA TRACK LIGHTS 28 C • 32 29 SALES AREA NIGHT LIGHTS 33 CASHWRAP REGISTER, I.G. 1435 822 720 SALES AREA TRACK LIGHTS C SPARE 34 31 SPACE MANAGER RECEPTACLE 0 660 540 360 DENIM NEON SIGN 32 36 33 SPACE 360 720 d 1 235 SALES AREA TRACK LIGHTS 34 C 39 35 SPACE Co 0 0 SPARE SPARE 36 41 SPARE 37 SPACE c1,0 ' 0 SPARE 42 LOAD PER PHASE: (N.E.C. CONNECTED) SPARE 38 11,900 TOTAL VA: 35.820 VA TOTAL AMPS: 99.43 A LCL 0 25% PER PHASE - 39 SPACE TOTAL LOAD PER PHASE: (N.E.C. DEMAND) 11,900 12,020 11,900 0 SPARE 40 41 SPACE ' ' 0 t 1 SPARE 42 LOAD PER PHASE: (N.E.C. CONNECTED) 9,268 9,330 9,316 TOTAL VA: 34,893 VA TOTAL AMPS: 96.925 A LCL 0 25% PER PHASE 2,317 2,333 2,329 TOTAL LOAD PER PHASE: (N.E.C. DEMAND) 11,585 11,663 11,645 VOLTAGE : 120/208V, 30, 4W MOUNTING : - BUS RATING : 225A PANELBOARD B MAIN 00 A. CIRCUIT BRE ESE RATED 150 A (SEE SERIES RATED NOTES) LOCATION : WR ENCLOSURE (IFS) ISOLATED GROUND BUS LCL LTG. ZONE CIR. NO. N.E.C. DESCRIPTION CB LOAD CB DESCRIPTION CIR. NO. LTG. ZONE LCL DESCRIPTION AMP POLE A B C AMP POLE 1.0 6.566 1 (WR) TELEPHONE BOARD 20 1 360 800 1,0 17.673 20 1 MUSIC / SOUND SYSTEM 2 SHOW WINDOW LIGHTING ALLOWANCE 3.675 1.0 3.675 3 (WR) TEMPERATURE CONTROLS 6.000 4, 1 9.360 500 1000 9.360 9.360 1•0 < 10K 0.5 REMAINING G KW 9.360 MOTORS SECURITY SYSTEM 4 0.000 0.000 1.0 0.000 5 DREAMSTEAMER O 30 3 0.000 * 1.0 3000 1500 AIR CONDITIONING SYSTEM 0.000* 1.0 0.000 * WALKIE RECEPTACLES 6 0.000* ELECTRIC WATER HEATER 3.000 1.0 7 3.000 3.000 MISCELLANEOUS 23.460 1.0 3000 1500 23.460 1.0 20 2 O WATER HEATER 8 63.734 70.736 79.466 9 ' ' * USE GREATER 30001500 ** N.E.C. ARTICLE 220 -12 REQUIREMENT - (200VA PER FOOT OF SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. i TRACK LIGHTING) OR ACTUAL INSTALLED TRACK LIGHTING VA. * * ** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. USE 112.5 KVA, 480V- 120/208V, 3 PHASE TRANSFORMER. 10 11 STOCKROOM RECEPTACLES 20 1 360 660 20 1 ELECTRIC WATER COOLER 12 13 STOCKROOM RECEPTACLES 720 Q SPARE 14 15 TV RECEPTACLE 800 9QQ MANAGER COMPUTER, I.G. 16 17 MICROWAVE 1200 500 FIRE ALARM CONTROL PANEL 18 19 REFRIGERATOR 1200 1080 SALES AREA RECEPTACLE 20 21 SPARE 0 00 SALES AREA RECEPTACLE 22 23 SENSORMATIC, I.G. 720 1260 SALES AREA RECEPTACLE 24 25 SPARE °720 SALES AREA RECEPTACLE 26 27 SPARE O 1260 SALES AREA RECEPTACLE 28 • 29 SENSORMATIC, I.G. 720 1080 SHOW WINDOW RECEPTACLE 30 31 CASHWRAP REGISTER, I.G. 720 01440 SPARE 32 33 CASHWRAP REGISTER, I.G. 720 SPARE 34 35 MANAGER RECEPTACLE 540 360 CASHWRAP UTILITY POWER 36 37 RTU RECEPTACLE 360 720 CASHWRAP UTILITY POWER 35 39 SPARE Co SPARE 40 41 SPARE ' ' c1,0 ' ' SPARE 42 LOAD PER PHASE: (N.E.C. CONNECTED) 11,900 12,020 11,900 TOTAL VA: 35.820 VA TOTAL AMPS: 99.43 A LCL 0 25% PER PHASE - - - TOTAL LOAD PER PHASE: (N.E.C. DEMAND) 11,900 12,020 11,900 SHREMSHOCK: >:ENGINEERING, INC. 6130 S. 1IR' ROAD WESTERVILL 614- 545_;_. TRANSFORMER LOAD SUMMARY SUPPLY V, 30, 4W, 60HZ SYM. ACTUAL VOLTAGE ACTUAL N.E.C. N.E.C. N.E.C. DESCRIPTION CONNECTED POWER DEMAND CONNECTED DEMAND DEMAND OWATER KW /KVA FACTOR KVA KW /KVA FACTOR KVA LIGHTING 6.566 1.0 6.566 6.566 1.25 8.208 TRACK LIGHTING 17.673 1,0 17.673 23.550 (312 FT) * 29.438 *0.150 SHOW WINDOW LIGHTING ALLOWANCE 3.675 1.0 3.675 4.800 . X24.00' ** 0.200) 6.000 RECEPTACLES 9.360 1.0 9.360 9.360 1•0 < 10K 0.5 REMAINING G KW 9.360 MOTORS 0.000 1.0 0.000 0.000 1.0 0.000 FIXED ELECTRIC SPACE HEATING 0.000 * 1.0 0.000 * 0.000 * 1.0 0.000 AIR CONDITIONING SYSTEM 0.000* 1.0 0.000 * 0.000 * 1.25 * * ** 0.000* ELECTRIC WATER HEATER 3.000 1.0 3.000 3.000 1.25 3.000 MISCELLANEOUS 23.460 1.0 23.460 23.460 1.0 23.460 TOTAL 63.734 63.734 70.736 79.466 NOTES * USE GREATER VALUE OF THE TWO CATEGORIES ** N.E.C. ARTICLE 220 -12 REQUIREMENT - (200VA PER FOOT OF SHOW WINDOW) MINUS ACTUAL INSTALLED SHOW WINDOW LIGHTING VA. * ** N.E.C. ARTICLE 220 -12 REQUIREMENT - THE GREATER OF (150VA PER 2 FOOT OF TRACK LIGHTING) OR ACTUAL INSTALLED TRACK LIGHTING VA. * * ** 125% OF THE LARGEST MOTOR OF COMPRESSOR IN SYSTEM. APPLIED ONLY ON ONE UNIT. USE 112.5 KVA, 480V- 120/208V, 3 PHASE TRANSFORMER. L.O. L.0 LO N.E.C. Connected Totals: 0A 9.268 kw N.E.C. Demand Totals: 0A 11.585 kw 0B 11.663 kw 0C 11.645 kw Total 34.893 kw 08 9.330 kw 0C 9.316 kw Total 27.914 kw (All Phases to be balanced to within 7% using Actual Load Totals.) Breaker Options: BABR - Solenoid Operated BABR Breaker LO - Handle lock -off device ST - Shunt Trip Type AUX - Auxiliary Contacts PA - Handle Padlock Attachment GFCI - Ground Fault Circuit Interrupter HACR - Heating, A/C & Refrigeration * LCL - Long Continuous Load ELECTRICAL EQUIPMENT DATA SYM. ITEM VOLTAGE HP. KW. F.L.A. FEEDERS TYPE OF CONN. BRANCH BREAKER DISC. SW. BUS/ FUSES REMARKS WIRE COND. OWATER HEATER 208V, 10 -- 3.0 -- 2 #12 THHN 1#12 G 1/2)� 'AC' TOGGLE SWITCH 20A -2P ___ ___ SEE NOTE NO. 1 BELOW O DREAM STEAMER 208V, 30 -- 9.0 __ 3 #8 THHN 1#10 G 1•F THRU RECEPTACLE 30A -3P m a a m O AHU -1 (WITH HEATING) 480V, 30 -- HEAT 71.1 3 #3 THHN 1 #8 G •• 1 1 /4 THRU UNIT DISC. SW. 90A -3P ___ - -- NO. 2 BELOW SEE NOTE O4 ACCU -1 480V, 30 -- -- 49.23 4 #8 THHN 1 #10 G in THRU UNIT DISC. SW. 50A -3P --- --- SEE NOTE NO. 2 BELOW NOTE: , SWITCH TO BE FURNISHED BY ESD &C AND INSTALLED BY ELECTRICAL CONTRACTOR. SWITCH TO BE FURNISHED AND INSTALLED BY MECHANICAL SUPPLIER. 1. 'AC' TOGGLE 2. DISCONNECT ELECTRICAL POWER GENERAL NOTES 1. HVAC CIRCUIT BREAKERS SHALL BE "HACR" TYPE WHEN REQUIRED BY EQUIPMENT NAMEPLATE PER N.E.C. 2. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT K.A.I.C. RATING (BUILDING SERVICE AVAILABLE FAULT CURRENT) OF LANDLORDS DISTRIBUTION EQUIPMENT PRIOR TO BID AND WORK COMMENCEMENT. IF FOUND TO BE HIGHER THAN PANEL RATING, NOTIFY YOUR ESD &C PROJECT MANAGER IMMEDIATELY. 3. ELECTRICAL CONTRACTOR SHALL BALANCE ALL PANELS AND ELECTRICAL EQUIPMENT TO 7% ( + / -) BETWEEN PHASES: A /8, B /C, A /C, REGARDLESS OF CIRCUITING INDICATED. 4. PROPER CLEARANCE MUST BE MAINTAINED ABOUT ELECTRICAL EQUIPMENT PER N.E.C. FIELD VERIFY EXACT MOUNTING SPACE AVAILABLE IN ELECTRICAL ROOM /AREA PRIOR TO INSTALLATION OF ELECTRICAL EQUIPMENT. 5. ALL PANEL BRANCH CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE. 6. ALL PANEL BUS BARS SHALL BE COPPER. 7. MOUNT A TYPEWRITTEN DIRECTORY BEHIND GLASS OR PLASTIC ON THE INSIDE OF EACH PANEL DOOR AND, ON THE DIRECTORY, SHOW THE CIRCUIT NUMBER AND COMPLETE DESCRIPTION OF ALL OUTLETS ON EACH CIRCUIT. 8. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS FOR A COMPLETE AND OPERABLE ELECTRICAL DISTRIBUTION SYSTEM. 9. ALL PANELBOARDS, SWITCHBOARDS AND LINE VOLTAGE CONTROL EQUIPMENT SHALL BE FACTORY MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ARC FLASH HAZARDS. MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSONS BEFORE EXAMINATION, ADJUSTING, SERVICING OR MAINTENANCE OF EQUIPMENT. 10. ELECTRICAL CONTRACTOR SHALL MAKE SURE ENTIRE INSTALLATION CONFORMS TO N.E.C. 110.3 - EXAMINATION, IDENTIFICATION, INSTALLATION, AND USE OF EQUIPMENT. 11. SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, AND CONTACTORS ARE TO BE "LISTED" AND "IDENTIFIED" AS RATED FOR A MINIMUM OF 75 *C CONDUCTOR TERMINATION. 12. IFS ENCLOSURE LIGHTING CONTROLS: SOLENOID OPERATED BABR BREAKERS ARE PROVIDED WITH IFS PANELS FOR STORE LIGHTING CONTROLS AND STOREFRONT SIGNS. SEE PANEL SCHEDULES FOR LIGHTING ZONE DESIGNATIONS (ie: ZONE A, B, C, D) 13. IFS ENCLOSURE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR IS HEREIN DESCRIBED: A. UNIT WILL BE SHIPPED TO PROJECT IN MULTIPLE SECTIONS AND THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR OFF- LOADING OF EQUIPMENT, INSPECTION OF EQUIPMENT FOR DAMAGE, VERIFICATION OF EQUIPMENT RECEIVED FOR PROPER STORAGE, SETTING AND MOVING OF EQUIPMENT INTO SPACE AS WELL AS REASSEMBLING OF SECTIONS INTO ONE COMPLETE UNIT PER MANUFACTURER'S DOCUMENTATION. B. ELECTRICAL CONTRACTOR SHALL CONNECT ALL PROVIDED INTERCONNECTING CABLES BETWEEN SECTIONS AND TORQUE CONNECTIONS PER MANUFACTURER'S REQUIREMENTS. C. ALL CONNECTIONS WITHIN THE TELEPHONE /DATA SECTION AND HVAC CONTROL SECTION OF THE IFS ENCLOSURE WILL BE DONE BY OTHERS. ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR INSTALLATION OF LOW VOLTAGE CONDUIT SYSTEM (IF REQUIRED BY CODE OR LANDLORD) INTO THESE SECTIONS ONLY. D. SWITCHBOARD WILL BE SHIPPED ON AN ENCLOSED SEMI - TRAILER. ELECTRICAL CONTRACTOR MUST ARRANGE FOR A FORKLIFT TO OFF -LOAD AT JOB SITE. ELECTRICAL CONTRACTOR WILL RECEIVE 24 NOTICE PRIOR TO DELIVERY. 14. ELECTRICAL CONTRACTOR SHALL INCLUDE ALL COSTS TO FURNISH AND INSTALL ALL LOW VOLTAGE WIRING IN CONDUIT, AS PART OF BASE BID. DEMARC DEMOLITION NOTES 1. THE G.C. SHALL NOT CUT THE MAIN TELEPHONE WIRES LEADING TO THE TERMINATION STRIP (DEMARC BLOCK) OR PHONE SYSTEM. 2. IF THE DEMARC IS TO BE RELOCATED, IT SHALL BE COORDINATED WITH EXPRESS TECHNICAL SERVICES (LTS). THE PRIMARY CONTACT IS BRENDEN SPIVEY AT 614 - 415 -4077, AND THE SECONDARY CONTACT IS ZELDA WARD AT 614 - 415 -2160. 3. THE G.C. SHALL ALLOW ADEQUATE TIME FOR RELOCATION IN THE CONSTRUCTION SCHEDULE. 4. IF THE WALL WITH THE TELEPHONE BLOCK IS SCHEDULED FOR DEMOLITION, THE ENTIRE BACKING PANEL SHALL BE REMOVED FROM THE WALL (WITHOUT DISCONNECTING THE WIRING) AND IT SHALL BE SAFELY SECURED IN THE CEILING UNTIL IT CAN BE RELOCATED TO THE NEW AREA OR REINSTALLED ON WALL. SERIES RATED NOTES 1. MAIN CIRCUIT BREAKER IN 'PANEL IFS' SHALL BE FULLY RATED TO PROVIDE AN INTERRUPTING RATING OF 65,000 AMPS RMS. 2. MAIN CIRCUIT BREAKER SHALL BE "SERIES" RATED WITH ALL OTHER FEEDER BREAKERS IN 'PANEL IFS' TO PROVIDE AN INTERRUPTING RATING OF 65,000 AMPS RMS. 3. PANELBOARDS OR OTHER EQUIPMENT THAT IS PROTECTED BY "SERIES" RATED OVERCURRENT PROTECTED DEVICES UPSTREAM SHALL BE MARKED WITH A PERMANENT LABEL THAT INDICATES THE SHORT- CIRCUIT RATING OF THE SERIES COMBINATION AND CALLS OUT THE SPECIFIC REPLACEMENT OVERCURRENT DEVICE(S) THAT CAN BE UTILIZED. L.O. L.0 L.0 N.E.C. Connected Totals: 0A 11.900 kw 0B 12.020 kw 0C 11.900 kw Total 35.820 kw N.E.C. Demand Totals: 0A 11.900kw 0B 12.020 kw 0C 11.900kw Total 35.820 kw (All Phases to be balanced to within 7% using Actual Load Totals.) Breaker Options: LO - Handle lock -off device ST - Shunt Trip Type AUX - Auxiliary Contacts PA - Handle Padlock Attachment HACR - Heating, A/C & Refrigeration * LCL - Long Continuous Load LO. Lighting Time Control Legend: A - Marketing Level Lighting Show Window Lights Show Window Receptacles Exterior Signage B - Stocking Stockroom (Non - Sales) Lighting C - Task Level 2/3 Sales Floor Lighting evenly distributed (preferably Down Lights) General Sales Floor Receptacles D - Sales Level Lighting Balance of Sales Floor Lighting Interior Display Lighting Display Cabinet Lighting Receptacles VERIFY MINIMUM 3" CONDUIT WITH 4 #350 KCMIL THHN + 114 CU G. NOTE: G.C. IS TO VERIFY LOCATION AND SIZE OF LANDLORD ELECTRICAL CONDUIT AND CONDUCTORS (IF EXISTING) PRIOR TO BEGINNING OF CONSTRUCTION INCLUDING OTHER RELATED WORKS. REFER TO FIELD SURVEY OR DESIGN CRITERIA. -LEASE LINE LANDLORD TENANT SPACE LO. a0S- (0. REVIEWED FOR CODE COMPLIANCE NFPA70 -NEC MAY 2aca City Of Tukwila BUILDING DIVISION LINE LEVEL POINT WHERE TO INTERCEPT /EXTEND CONDUIT (SERVICE FEEDER) STUB -IN. PROVIDE PULL /CONNECTION BOX AS NECESSARY, SIZE AS PER CODE REQUIREMENTS. ASSUMED FAULT CURRENT IS 65,000 SYM AMPS AT LL PANEL. ELECTRICAL CONTRACTOR TO EXTEND THE SERVICE FEEDER AS SHOWN, 3 "C, 4 #350 KCMIL THHN + 114 G. FIELD VERIFY. E.C. SHALL FURNISH AND INSTALL A 1" CONDUIT AND PULLWIRE FROM DEMARC TO IFS ENCLOSURE. CEILING LINE SEE SERIES RATED NOTE FAULT CURRENT IS 40,747 SYM AMPS. / -PANEL IFS; 277/480V; 30; 4W; 60HZ SUPPLY; 400A BUSS; 65,000 A.I.C. PANEL HEIGHT, LANDLORD MAIN SWITCHBOARD, 277/480V, 30, 4W, 60HZ. FIELD VERIFY. VERIFY EXISTING TENANT ELECTRICAL SERVICE METER COMPLETE WITH CT'S. FIELD VERIFY REQUIREMENTS WITH THE LANDLORD AND /OR UTILITY COMPANY, PRIOR TO BID AND WORK COMMENCEMENT. 400A, 277/480V, 30, TENANT MAIN DISCONNECT SWITCH WITH (3) 300 LPS -RK FUSES. FIELD VERIFY REQUIREMENTS WITH THE LANDLORD ENGINEER PRIOR TO BID AND WORK COMMENCEMENT. TRANSFORMER AND PANEL FEEDER FURNISHED BY IFS MFGR. AS REQUIRED. E.C. TO MAKE FINAL CONNECTIONS TO PANELBOARD (TYP.) FAULT CURRENT IS 40,747 SYM AMPS. ELECTRICAL CONTRACTOR TO BALANCE TRANSFORMER TO SUPPLY 120V±3% AFTER ALL CONNECTIONS ARE MADE AND RUNNING. PROVIDE BALANCE SHEET TO THE ESD &C PROJECT MANAGER AT PUNCHLIST. M.C.B. 300A /3P © HACR1 90A 3P O 0 SPARE O 0 0 0 ACCU -1 HACR 4 4 50A 3P SPACE 5 0 (..?\_s O 0 SPACE O 0 TRANSFORMER 1751 3P O 0 EE SERIES RATED NOTE #2. (TYP.) FAULT CURRENT IS 16,162 SYM AMPS. 3#2/0 THHN 112.5 KVA 4#1/0 + 1 #6 XHHW FAULT CURRENT IS 13,701 SYM AMPS. 1 4 #1/0 + 1 #6 XHHW PANEL "A" 150A -3P MCB 19 33 53 7I 93 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 1 1 ❑ 00 a m) I 1 1D❑ In a a a 0 m a ❑ml Im❑ a CO l I m a a m 1M a ❑ m m a ❑ m m ❑ ❑ m m a a 0 m a a m m a a m m a a m m a ❑ cc m a amI ma' ❑ 00 ' In a am ma m a ❑ m ❑ m , m a m 0 ❑ m I "❑ CO I m a 1 1 1 1 FAULT CURRENT IS 13,701 SYM AMPS. E 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 PANEL "B" 150A -3P MCB 7 7 7 7 2 ❑ CO M ❑ CO M a a m m a a m ❑ 03 M ❑ O CO m a a m M ❑ ❑ 00 M ❑ a CO M a a m M a O 13 ❑ CO m 0 M a ❑ m M 0 ❑ M ❑ m m a ❑ m M a a1 M ❑ ❑ m m a O CO m 0 ❑ m M ❑ ❑ m 13 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 B -3 TELEPHONE /HVAC EQUIPMENT CONTROL PANEL TOP OF IFS PANEL B -1 DEMARCATION POINT PROVIDED BY PHONE CO, (REFER TO DEMARC DEMOLITION NOTES). .C. TO PROVIDE AND INSTALL PLYWOOD SURFACE MOUNTED BACKBOARD ON WALL. LOCATE ADJACENT TO IFS PANEL LECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL #6 THHN GROUND CONDUCTOR, TERMINATED AT GROUNDING ELECTRODE CONDUCTOR, CONFORMING TO N.E.C. 800.40 AND LOCAL UTILITY REQUIREMENTS. FINISH FLOOR LEVEL IFS IS A SINGLE SWITCHGEAR ENCLOSURE THAT MEETS NEMA STANDARD PB -2 AND UL 891 (SWITCHBOARD CONSTRUCTION). #1/0 THHN GROUND CONDUCTOR (SYSTEM BONDING JUMPER) TO BLDG. STEEL, METALLIC WATER PIPE AND /OR GROUND ROD PER N.E.C. AND LOCAL CODES. SHORT CIRCUIT CALCULATIONS BASED ON 50 FEET FROM LANDLORD ELECTRICAL EQUIPMENT TO TENANT ELECTRICAL EQUIPMENT. FIELD VERIFY EXACT DISTANCE PRIOR TO BID. ELECTRICAL RISER DIAGRAM, PANEL SCHEDULES, AND NOTES N.T.S. A E 4EE$ - - 6 7 - - / ( 0 . - ( 7 O 0 Z a V1 O r a °� N Vl LJ0°� a" V W F W = U O a O U �' m W w \ v d ° N Z Q O °O �j 2 Z U Z W Z (7 < Z oZ3° Z �Za�"g 1:1-:' ::M1 O W �,�0 � ul N V) ).i W w _ w V) W m 2 U - Z W Z F = =ace . F Z 3 ^ w= g O Z O a H wry 3 a Wo i W _ = J� v �a ;so V] O o 1-. H Z U' W O U °< -0 <� 0 0 V) U N N .. W W W 0 W U O W Z O W d• ° ._ 2 0� W Z 0. F- U 0. ce w w 6 O W ° V1 V1 Z W w r Z QN3a= = i W V 1 W 3 W w o 0 DC Q a = W F- 2 O .. -0o W J O Z 3�0 O 2 ° , 0a _ EarVrc,CD W O W CD O a. - K 0_ - 11 0 o ,mn,„ a O`' V1 Wa0k- Z 0 0 z a z U >' Q V) E Q V W w =O °WZ2 d O W W W VI w m ° W 2=F-m V) O O W Z° Z Z Z C 7 W O °W VS1-) Z a O O W U 4 U = 7E' 2 3 W 0 O C S W F- 0 PROJECT INFORMATION: N 0 00 u7 O o 0 00 F- U Z W .. O -� L11 0 0 a Nd ex: a. W oo O O o0 0 Q o =o 0 00 O QO�w cn 1- U W LAJ >>-- I- 0_ 6.1 :2 o OUwV) V) o W REVISIONS: REQUIRED BY: DATE RECEIVED CITY OF TUKWILA APR 2 . 2008 r ; ivn 1 CSI 1 INDICATES NO REVISION TO THIS SHEET DATE ISSUED: DESIGNED BY: DRAWN BY: CHECKED BY: 04/18/2008 AOH AOH RAP ELECTRICAL PANELS AND x RISER DIAGRAM DRAWING NUMBER: i