Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL08-0538 - WESTFIELD SOUTHCENTER MALL - SELECT COMFORT
SELECT COMFORT 436 SC MALL 07 -21 -08 ELO8-538 CitAf Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us Parcel No.: 6364200010 Address: 436 SOUTHCENTER MALL TUKW Suite No: ELECTRICAL PERMIT Permit Number: EL08 -538 Issue Date: 05/22/2008 Permit Expires On: 11/18/2008 Tenant: Name: SELECT COMFORT Address: 436 SOUTHCENTER MALL , TUKWILA WA Owner: Name: WESTFIELD PROPERTY TAX DEPT Phone: Address: PO BOX 130940 , CARLSBAD CA Contact Person: Name: MIKE PETERSON Phone: 909 949 -0380 x 111 Address: 1659 W ARROW RTE , UPLAND CA Contractor: Name: SIGN -TECH ELECTRIC LLC Phone: 253- 922 -2146 Address: 5113 PACIFIC HWY E, SUITE 12 , Contractor License No: SIGNTEL988BG Expiration Date: 01/07/2010 DESCRIPTION OF WORK: INSTALL LIGHTS, SWITCHES, BOXES, AND TRIMS (REFERENCE EXPIRED APPLICATION EL07 -598) Value of Electrical: $26,000.00 Fees Collected: $635.50 Type of Fire Protection: National Electrical Code Edition: 2005 Electrical Service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: Date: c'--,I-al- - I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perfforn nce of work. I am auth' ' ed to sign and obtain this electrical permit. y// Signature: Print Name: Date: _5—p 2 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/07 EL08 -538 Printed: 05-22 -2008 Parcel No.: 6364200010 Address: Suite No: Tenant: • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us 436 SOUTHCENTER MALL TUKW SELECT COMFORT PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: EL08 -538 ISSUED 05/08/2008 05/22/2008 1: ** *ELECTRICAL * ** 2: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 3: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 4: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 5: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 6: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 7: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. Signature: Print Name: m trt 044 Z./ Date: �^ a doc: Cond -Elec EL08 -538 Printed: 05-22 -2008 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us Electrical Permit No. /V1/ D Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: g60 (CFiv%L a bU Y Tenant Name: &I e cr ec'lu•_r-,-14- Property Owners Name: ().� 1 N4-1-F ( Address: 436 S:Dor-lc-e r "Aka King Co Assessor's Tax No.: tQ9. L? 4147^Q)t Suite Number: / cos- Floor: New Tenant: [l Yes ❑ ..No —T kcw !(q City tteiq State 981/F Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: Ak Mailing Address: I(5 1 (A ). C , Day Telephone: E -Mail Address: f.-(p f--5' So t'-- @ (, wA.iseCW�'$r� City G° 7Fax Number: 9o`?- ? 9 - 6384 -x t ( ( A T 1'3F16, 909 sC 49 -8 �x).0 ELECTRICAL CONTRACTOR INFORMATION Company Name: 57 C— tJ P_c (7"---R1?) Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip Valuation of Project (contractor's bid price): $ 2-6) O0 t Scope of Work (please provide detailed information): t-1TS / Sc� �- -4 Will service be altered? ❑ Yes [r No Type of Use: Type of work: ❑ New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Proaert v Served bv: Puget Sound Energy ❑ Seattle City Light H: Applicauons\Forms- Applications On Une\4 -2007 - Elecmcal Pemut Application doe bh Adding more than 50 amps? ❑ Yes L 'No ❑ Remodel ❑ Telecommunication []Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ... .......... .......... $140.00 (including an attached garage) ❑ Garages, pools, spas and outbuildings $75.00 ea ❑ Low voltage systems (alarm, furnace thermostat) $55.00 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $75.00 (no added/altered circuits) ❑ Service change with added/altered circuits $75.00 number of added circuits $10.00 ea ❑ Circuits added/altered without service change $50.00 (up to 5 circuits) ❑ Circuits added/altered without service change $50.00 (6 or more circuits) $7.00 ea ❑ Meter /mast repair $65.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) MULTI - FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured/mobile home service $80.00 (excluding garage or outbuilding) ❑ Carnivals $75.00 Number of concessions $10.00 ea PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER Oft ELECTRICAL CONTRACTOR: Signature: ( Print Name: Mailing Address: car Date: 5NO 8 Day Telephone: IDate Application Accepted: t i ) City State Zip Date Application Expires: Staff Initials: H°ApplicanonsTanns- Apphcaoons On 4n&4.2007- Electrical Peril Applicationdoc bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 6364200010 Permit Number: EL08 -538 Address: 436 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/08/2008 Applicant: SELECT COMFORT Issue Date: Receipt No.: R08 -01531 Payment Amount: $635.50 Initials: JEM Payment Date: 05/08/2008 02:38 PM User ID: 1165 Balance: $0.00 Payee: TIMBERWOLFF CONSTRUCTION, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 2229 635.50 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR ELECTRICAL PLAN - NONRES 000.322.101.00.0 508.40 000.345.832.00.0 127.10 Total: $635.50 2148 05/08 9711 TOTAL 635.50 dnr.• Raraint -OR Printwri. ns- nR -2nnR INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ttot-53\7 Project: ,�/�.� ,t,,f%� CD��tl Type of Inspection: 1100 Address: q314 hiy ` riV\. Date Called: � Special Instructions: Date Wanted: 7111 a.�—. Requester: Phone No: Approved per applicable codes. Corrections required prix .to approval. COMMENTS: Inspector: Date: 0-712 if OE ri $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: (Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 INSPECTION RECORD Retain a copy with permit twV-- sus PERMIT NO. (206)431 -3670 Project: / _' e Cr (ptr ��` ;� Type of Inspection: - 5-roci. s-r 4 F j`oo Address: �� �7Y� Date Called: Special Instructions: Date Wanted: 'j (� p.m. Requester: Phone No: DApproved per applicable codes. Corrections required prior to approval. COMMENTS: PA- - 5-roci. s-r 4 F CC �fZCn�5 r'1 ki>L` (1^141— Pc-7J91,4 Fret C rub Inspector: Date: jric El $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: n&.. ffia�vm^:''•`"nitt r�+�rfs.a INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit Eco`Y- Stg PERMIT NO. Project: 56Lc Co/IA(� Type of Inspection: 2-too Address: 36 ii Date Called: Special Instructions: Date Wanted: jt� 1/ 4. Requester: Phone No: DIApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector:j, $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be 1Q paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. wAitic (Date: Receipt No.: 'Date: INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 INSPECTION RECORD Retain a copy with permit 601-5* PERMIT NO. Project: satcr C k&T Type of Inspection: 2x04 g(LocI tic Actors Act.CS5 Address: 1-13‘ O Piiiti Date Called: ir- - URATt IMO Pit4ti,, DItEcToe.f Special Instructions: Date Wanted: ft ` a.m., Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (Clet ' f idDmit,, nee 4Qo J'K.- oF mozetAkAf L14 irtek g(LocI tic Actors Act.CS5 - 5 0 Pro e'r a cic rd & \AV isJ r*trki 1 ." or sox, cvcivt ir- - URATt IMO Pit4ti,, DItEcToe.f - [nf DI CA'rE lh%A-iJ C 1tait_ �j- C 11-4)4k C o\/r\ - (o+Jg.t.I. 14 Inspector: —/;/ 636\ial (Date: Q1 (lip ich ❑ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be k. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ...-ISS..,_._ �.._� __g .,_.■ INSPECTION NO. INSPECTION RECORD Retain a copy with permit Cog-Ct PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 1- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: S6 t." �1�Fp Type of Inspection: 700 Address: ,154 /I Date Called: Special Instructions: s Date Wanted: tO� tJ a:m. ' Requester: Phone No: 414 Approved per applicable codes. Corrections required prior to approval. CO MENTS: r�. 1) f r itotel Inspector: Date: 01 lQ� O� f 0 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: ar.. - a . - INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION IL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: ! C_uf.1r Type of Inspection: 7oo 2.— TQ SFati...AtA�, DTI L41 Address: q 3 � PI AU./ Date Called: t410 d cc-6p Ar CA C tAi s I<,tc.. LO. — Rt r of f. ,DPIPf•kt Tv 1 PEA s) S Fit Special Instructions: Date Wanted: �} f v 3 P•m� Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: - V't af1142kiJai (f illJt ILO roc. TQ SFati...AtA�, DTI L41 ..- 13ZLT T�.,4J 4& 1 (tor - 491J, • +ttrl _ 9 (0 11.4 t a.C.-0 PAL. t410 d cc-6p Ar CA C tAi s I<,tc.. LO. — Rt r of f. ,DPIPf•kt Tv 1 PEA s) S Fit — Pt of %DC IA./DIVA/4 C -t-c) Lego v (k 'PKC JT . 3D" LJgge q2" c d Inspector: jt1 6E7* Date: Q7'0 /0\5 $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: AL -ci PP4t _ -. aai J�aa� act g'' ems,,. INSPECTION RECORD Retain a copy with permit INSPE ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 0- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 ti Project: Cori fl).- Type of Inspection: 7003 Address: q 3 T 14 644, Date Called: Special Instructions: Date Wanted: (/ Z3 p.m. Requester: Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: Pik 041-Q.p U� .3m1 reofwr .0t.1 r) Inspector: (Date: V &/ GS LJ $60.00 REINSPECTION FEE REbUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 0 Receipt No.: Date: INSPECTION NO. INSPECTION RECORD Retain a copy with permit 6.0\1-s31 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION CL 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: cs cr coilwr. Type of Inspection: .7003 Address: I 1 3(0 littij Date Called: Special Instructions: Date Wanted: W Z4..r Requester: -' Phone No: EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: - t tss'A K. D t sue.. 4 E C4d c4- - , =J J t Abo iv kEc cii5 N oT ('J STML4.D Inspector: Date: 043 poi? LJ $60.00 REINSPECTION FEE REWIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: !Date: .tea. - eta INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION e- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: Cir Type of Inspection: 7003 Address: 136 ( Date Called: Special Instructions: Date Wanted: (p)a.m Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Pa 0. K UPius Inspector: Date: 04 l3 dg LJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION R 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 euig -ss\z Projectoz ev C'r Type of Inspection: 7 � Address: 3 Date Called: Special Instructions: Date Wanted: I) ) '! a.m. ( Requester: ttt Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 9.K_ d4P (IOLA-5 Inspector: Date: oco I, 01 LJ $60.00 REINSPECTION FEE REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: 'Date: uiS6s er4Fffi. ' }W �' .`�«af19.. r �a.._..�� +Le�6: • ..a,y • • • �_�.A INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION tie- 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Pr ect: t 5 4 % 61),rn,P1-� T Type of Inspection: -70-. 3 Addres : yg& Sur7/c..t /)2 t, Date Called: Special Instructions: Date Wanted: r e/ a Requester: Phone No: proved per applicable codes. LJ Corrections required prior to approval. C•MMENTS: 6/4 - m/s/Ng -- S4LFs .9/'119 C>,vL/ Inspector �uT �0/ 1 Date: 4/r /D $58.00 REINSPECTION FEE REQUIRED. Prior o inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: • 2006 Washington State Nonresidential Energy Code Compliance Form 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Project Info Project Address Select Comfort 2 Southcenter Mall Date 5/5/2008 633 Southcenter Parkway, #1005 For Building Department Use Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: FILE COpy Permit No. REVIEWED FOR CODE COMPLIANCE NFPA 70 - NEC MAY 1 5 X008 i Of Tukwila B LDI G DM ION CITY OF TUKWILA MAY 0 8 2008 PERMIT CENTER F 5Sb 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary 2006 Washington State Nonresidential Energy Code Compliance Forms LTG -INT Revised July 2007 Project Info Project Address Select Comfort g Southcenter Mall Date 5/5/2008 633 Southcenter Parkway, #1005 For Building Department Use Tukwila, WA 98188 Applicant Name: Applicant Address: Applicant Phone: Project Description ❑ New Building ❑ Addition ./ Alteration Plans Induded Indicate controls (Sections 1513) including commissioning requirements on plans. Compliance Option 0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting ❑ Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. Maximum Allowed Lighting Wattage Location (floor /room no.) Occupancy Description Allowed Watts per ft2** Area in ft2 Allowed x Area Retail Sales 1.50 1465.0 2197.5 Sales Display 1.50 1170.0 1755.0 R2 - 60W PAR Downlight 5 60.0 300.0 " From Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 3952.5 Proposed Lighting Wattage Location (floor /room no.) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed C2 - 2 -Lamp Fluorescent Wraparound 1 58.0 58.0 R1 - Recessed CFL Downlight 11 95.0 1045.0 R2 - 60W PAR Downlight 5 60.0 300.0 R3 - Recessed CFL Downlight 5 60.0 300.0 LT - Decorative Custom Pendant 1 300.0 300.0 W1 - ADA CFL Wall Sconce 4 40.0 160.0 T - Track Ltg., 50w /Ln. Ft. 20 50.0 1000.0 T4 - Monopoint 4 75.0 300.0 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 3463.0 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For hard -wired ballasts only, the default table in the NREC Technical Reference Manual may also be used. For track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts /Fixture blank. 2006 Washington State Nonresidential Energy Code Compliance Form Interior Lighting Summary (back) LTG -INT 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Prescriptive Spaces Occupancy: O Warehouses, storage areas or aircraft storage hangers O Other Qualification Checklist Note: If occupancy type is "Other" and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521) ❑ Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures which are non - lensed with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8 lamps, and d) hard -wired elec- tronic dimming ballasts. Screw -in compact fluorescent fixtures do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps <= 150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Lighting Power Allowance (LPA Use' LPA` (W /sf) Use' LPA` (W /sf) Automotive facility 0.9 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools. hospitals, institutions, museums, banks, churches) 1.0 Convention center 1.2 Penitentiary and other Group 1 -3 Occupancies 1.0 Courthouse 1.2 Police and fire stationsB 1.0 Cafeterias, fast food establishments', restaurants/bars' 1.3 Post office 1.1 Dormitory 1.0 Retail10, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.5 Exercise center 1.0 School buildings (Group E Occupancy only), school classrooms, day care centers 1.2 Gymnasia'', assembly spacese 1.0 Theater, motion picture 1.2 Health care clinic 1.0 Theater, performing arts 1.6 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.2 Transportation 1.0 HoteVmotel 1.0 Warehouses ", storage areas 0.5 Hotel banquet/conference/exhibition hall•; 2.0 Workshops 1.4 Laboratory spaces (all spaces not classified °laboratory° shall meet office and other appropriate categories) 1.8 Parking garages 0.2 Laundries 1.2 Libraries' 1.3 Plans Submitted for Common Areas Only' Manufacturing facility 1.3 Main floor building lobbies3 (except mall concourses) 1.2 Museum 1.1 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.8 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by two percent per foot of ceiling height above twenty feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by two percent per foot of ceiling height above twelve feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by two percent per foot of ceiling height above nine feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.10 w/ft may be used. 8) Reserved. 9) For indoor sport toumament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W /ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque). and lighting for free - standing display where the lighting moves with the display are exempt. An additional 1.5 w /ft2 of merchandise display luminaires are exempt provided that they comply with all three of the following: a) located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). b) adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). c) fitted with LED, tungsten halogen, fluorescent, or high intensity discharge lamps. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and height, is submitted, the square footage for a warehouse may be defined, for computing the interior Unit Lighting Power Allowance, as the floor area not covered by racks plus the vertical face area (access side only) of the racks. The height allowance defined in footnote 2 applies only to the floor area not covered by racks. • 2006 Washington State Nonresidential Energy Code Compliance Form fighting, 2006 Washington State Motor, and Transformer Permit Plans Checklist LTG -CHK Nonresidential Energy Code Compliance Forms Revised July 2007 Project Address Select Comfort B Southcenter Mall Date 5/5/2008 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2006 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) yes 1513.1 Local controUaccess Schedule with type, indicate locations E1.0 yes 1513.2 Area controls Maximum limit per switch E1.0 n.a. 1513.3 Daylight zone control Schedule with type and features, indicate locations n.a. vertical glazing Indicate vertical glazing on plans n.a. overhead glazing Indicate overhead glazing on plans yes 1513.4 Display /exhib /special Indicate separate controls El. 0 1513.5 Exterior shut -off Schedule with type and features, indicate location n.a. (a) timerw /backup Indicate location n.a. (b) photocell. Indicate location 1513.6 Inter. auto shut -off Indicate location n.a. 1513.6.1 (a) occup. sensors Schedule with type and locations n.a. 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans n.a. 1513.7 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) yes I 1514 'Max. watts `Indicate watts for each exit sign 1 I LIGHTING POWER ALLOWANCE (Section 1530 -1532) yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture n.a. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) yes I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I TRANSFORMERS (Section 1540) yes I 1540 'Transformers 'Indicate size and efficiency IE2.0 I If "no" is circled for any question, provide explanation: 2006 Washin•ton State Nonresidential Energ Code Com•liance Form lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2006 Washington State Nonresidential Energy Code Compliance Forms Revised July 2007 Lighting - General Requirements 1513 Lighting Controls: Lighting, including exempt lighting in Section 1512, shall comply with this section. Where occupancy sensors are cited, they shall have the features listed in Section 1513.6.1. Where automatic time switches are cited, they shall have the features listed in Section 1513.6.2. 1513.1 Local Control and Accessibility: Each space, enclosed by walls or ceiling- height partitions, shall be provided with lighting controls located within that space. The lighting controls, whether one or more, shall be capable of tuming off all lights within the space. The controls shall be readily accessible, at the point of entry/exit, to personnel occupying or using the space. EXCEPTIONS: The following lighting controls may be centralized in remote locations: 1. Lighting controls for spaces which must be used as a whole_ 2. Automatic controls. 3. Controls requiring trained operators. 4. Controls for safety hazards and security. 1513.2 Area Controls: The maximum lighting power that may be controlled from a single switch or automatic control shall not exceed that which is provided by a 20 ampere circuit loaded to not more than 80 %. A master control may be installed provided the individual switches retain their capability to function independently. Circuit breakers may not be used as the sole means of switching. EXCEPTIONS: 1. Industrial or manufacturing process areas, as may be required for production. 2. Areas less than 5% of the building footprint for footprints over 100,000 ft2. 1513.3 Daylight Zone Control: All daylighted zones, as defined in Chapter 2, both under overhead glazing and adjacent to vertical glazing, shall be provided with individual controls, or daylight- or occupant- sensing automatic controls, which control the lights independent of general area lighting. Contiguous daylight zones adjacent to vertical glazing are allowed to be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations (i.e. north, east, south, west). Daylight zones under overhead glazing more than 15 feet from the perimeter shall be controlled separately from daylight zones adjacent to vertical glazing. EXCEPTION: Daylight spaces enclosed by walls or ceiling height partitions and containing 2 or fewer Tight fixtures are not required to have a separate switch for general area lighting. 1513.4 Display, Exhibition and Specialty Lighting Controls: All display, exhibition or specialty lighting shall be controlled independently of general area lighting. 1513.5 Automatic Shut -off Controls, Exterior: Lighting for all exterior applications shall have automatic controls capable of tuming off exterior lighting when sufficient daylight is available or when the lighting is not required during nighttime hours. Lighting not designated for dusk -to -dawn operation shall be controlled by either: a. A combination of a photosensor and a time switch; or b. An astronomical time switch. Lighting designated for dusk -to -dawn operation shall be controlled by an astronomical time switch or photosensor. All time switches shall be capable of retaining programming and the time setting during loss of power for a period of at least 10 hours. EXCEPTION: Lighting for covered vehicle entrances or exits from buildings or parking structures where required for safety, security, or eye adaptation. 1513.6 Automatic Shut -Off Controls, Interior: Buildings greater than 5,000 ft2 and all school classrooms shall be equipped with separate automatic controls to shut off the lighting during unoccupied hours. Within these buildings, all office areas less than 300 ft2 enclosed by walls or ceiling - height partitions, and all meeting and conference rooms, and all school classrooms, shall be equipped with occupancy sensors that comply with Section 1513.6.1. For other spaces, automatic controls may be an occupancy sensor, time switch or other device capable of automatically shutting off lighting. EXCEPTIONS: 1. Areas that must be continuously illuminated (e.g., 24 -hour convenience stores), or illuminated in a manner requiring manual operation of the lighting. 2. Emergency lighting systems. 3. Switching for industrial or manufacturing process facilities as may be required for production. 4. Hospitals and laboratory spaces. 5. Areas in which medical or dental tasks are performed are exempt from the occupancy sensor requirement. 1513.6.1 Occupancy Sensors: Occupancy sensors shall be capable of automatically turning off all the lights in an area, no more than 30 minutes after the area has been vacated. Light fixtures controlled by occupancy sensors shall have a wall- mounted, manual switch capable of tuming off lights when the space is occupied. EXCEPTION: Occupancy sensors in stairwells are allowed to have two step lighting (high -light and low - light) provided the control fails in the high -light position. 1513.6.2 Automatic Time Switches: Automatic time switches shall have a minimum 7 day clock and be capable of being set for 7 different day types per week and incorporate an automatic holiday "shut -off' feature, which tums off all Toads for at least 24 hours and then resumes normally scheduled operations. Automatic time switches shall also have program back -up capabilities, which prevent the loss of program and time settings for at least 10 hours, if power is interrupted. Automatic time switches shall incorporate an over -ride switching device which: a. is readily accessible; b. is located so that a person using the device can see the lights or the areas controlled by the switch, or so that the area being illuminated is annunciated; c. is manually operated; d. allows the lighting to remain on for no more than 2 hours when an over -ride is initiated; and e. controls an area not exceeding 5,000 «2 or 5% of the building footprint for footprints over 100,000 ft2, whichever is greater. 1513.7 Commissioning Requirements: For lighting controls which include daylight or occupant sensing automatic controls, automatic shut -off controls, occupancy sensors, or automatic time switches, the lighting controls shall be tested to ensure that control devices, components, equipment and systems are calibrated, adjusted and operate in accordance with approved plans and specifications. Sequences of operation shall be functionally tested to ensure they operate in accordance with approved plans and specifications. A complete report of test procedures and results shall be prepared and filed with the owner. Drawing notes shall require commissioning in accordance with this paragraph. 1514 Exit Signs: Exit signs shall have an input power demand of 5 Watts or less per sign_ Motors - General Requirements 1511 Electric Motors: All permanently wired polyphase motors of 1 hp or more, which are not part of an HVAC system, shall comply with Section 1437. EXCEPTIONS: 1. Motors that are an integral part of specialized process equipment. 2. Where the motor is integral to a listed piece of equipment for which no complying motor has been approved. Transformers - General Requirements SECTION 1540 — TRANSFORMERS The minimum efficiency of a low voltage dry-type distribution transformer shall be the Class I Efficiency Levels for distribution transformers specified in Table 4 -2 of the "Guide for Determining Energy Efficiency for Distribution Transformers" published by the National Electrical Manufacturers Association (NEMA TP- 1- 2002). • PERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL08 -538 DATE: 05 -08 -08 PROJECT NAME: SELECT COMFORT SITE ADDRESS: 436 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: v 6ig 'vision Fire Prevention Public Works ❑ Structural Planning Division Permit Coordinator n n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-13 -08 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROU ING: Please Route Structural Review Required REVIEWER'S INITIALS: n No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06-10-08 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents routing slip.doc 2 -28 -02 Look Up a Contractor, Electric or Plumber License Detail Washington State Department of Labor and Industries Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. License Information License SIGNTEL988BG Licensee Name SIGN -TECH ELECTRIC LLC Licensee Type ELECTRICAL CONTRACTOR UBI 602152490 Ind. Ins. Account Id Business Type LIMITED LIABILITY COMPANY Address 1 5113 PACIFIC HWY E #12 Address 2 City FIFE County PIERCE State WA Zip 98424 Phone 2539222146 Status ACTIVE Specialty 1 GENERAL Specialty 2 UNUSED Effective Date 1/7/2002 Expiration Date 1/7/2010 Suspend Date Separation Date Parent Company Previous License Next License Associated License MORRIT *943K6 Electrical Administrator Information License MORRIT *943K6 Name MORRISON, TRAVIS Status ACTIVE Business Owner Information Name Role Effective Date Expiration Date MENDENHALL, JOHN C PARTNER/MEMBER 01/07/2002 MENDENHALL, LINDA D PARTNER/MEMBER 01/07/2002 Page 1 of 2 https: // fortress .wa.gov /lnifbbip /printer.aspx ?License= SIGNTEL988BG 05/22/2008 LANDLORD NOTES A. PER CODE, INSTALL SELF- CONTAINED BATTERY PACK EMERGENCY LIGHTING THROUGHOUT DEMISED PREMISES. B. LIGHTING AND LIGHTING CONTROL SHALL COMPLY WITH WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE. C. STOREFRONT SIGNAGE AND LIGHTING TIMECLOCKS SHALL BE SET TO MALL'S OPERATING HOURS. D. TRACK LIGHTING MUST BE INSTALLED IN RECESSED TROUGH AT STOREFRONT AND FORWARD SELLING AREAS. = = = = == T S1 c_ = _--_= L -13d 51 L -13d = = = =_= 51 L -13d R2 L— 9 TB1 • R1 —EM L -9b 0 R3 L -9b T1(3),TL4' -0 7, 1 L_J O R3 L -9b T1(9),T( L -3 OOR1 q2 L -5 L -5 NL ( LT —13d T1(4),j — /a TB1 R1 —EM L -9b • 0 L -9br- L -7a T1(7),T6' -0 ") L -7a 0 T1(3),E2' -0 ") L- L� S1 L -13d = = = = == 51 L -13d C — — — — LIGHT FIXTURE SCHEDULE PROVIDED BY SELECT COMFORT INSTALLED BY GC SYMBOLTYPE DESCRIPTION MANF. MODEL NUMBER LAMP COMMENTS C2 FLUORESCENT W /LENSE(4') SURFACE MTD TOILET RM HE WILLIAMS ESD 213232EW TWO F32T8 /SP30 /ECO SURFACE MOUNTED- TOILET ROOM F2 2' X 4' PRISMATIC TIC FL OURESCENT CRESCENT 24GP332UNIV THREE F32T8 /SP30 STOCKROOM • R1 RECESSED COMPACT FLUORESCENT DOWNLIGHT INDY LIGHTING ELATE C852WTL - TRIM - HOUSING ELATE C852WTL - TRIM ELATE HB -28 - HANGER BAR TWO F42TBX /830 /A /4P /EOL "WHEAT" REFLECTOR, LOW IRIDESCENT FINISH, NIGHT LIGHTING FIXTURES NOTED AS "R1 NL" ON PLAN. • R1 -EM RECESSED COMPACT FLUORESCENT DOWNLIGHT INDY LIGHTING ELATE C8H- 226/42T/BR EMERGENCY HOUSING ELATE C852WTL -TRIM ELATE HB -28 - HANGER BAR TWO F42TBX /830 /A /4P /EOL "WHEAT" REFLECTOR, LOW IRIDESCENT FINISH 0 R2 RECESSED ADJUSTABLE DOWNLIGHT INDY LIGHTING ELATE P8A-P38 -HOUSING ELATE P800A -P38 -WTL - TRIM ONE 60 PAR /HIR /S /SP1 U 75W AT STOREFRONT DISPLAY WINDOWS 0 R3 RECESSED COMPACT FLUORESCENT DOWNLIGHT INDY LIGHTING ELATE C9HD- 226/42T - HOUSING ELATE C952 -T- WTL -FD - TRIM TWO F32TBX /830 /A /4P /EOL "WHEAT" REFLECTOR, GLASS DISK SHIELDS LAMP 0 R4 RECESSED WALL WASHER JUNO TC2-261W-WH PAR LAMPS, 75 WATT FLOOD 50W AT STOREFRONT DISPLAY BED 0 W1 WALL SCONCE Y LIGHTING DOLCE 1 ADA WALL SCONCE ONE GE ENERIC ESIGN 5 NEMA GENERIC DESIGNATION :ONE FT38W/2G11/830 BACK WALL FLANKING CHECKOUT MOUNT APPROX 72" AFF T SURFACE MOUNTED TRACK AND CONNECTORS JUNO SALES AREA CEILING ' 0 T1 TRACK HEAD JUNO T239WH ONE 50PAR /HIR /S /SP10 gT4 MONO POINT TRACK HEAD JUNO T239WH ONE 75W30PAR /HIR /S /SP10 S1 48" SURFACE MOUNTED STIP FLUORESCENT METALUX ONE T8 FLUORESCENT LAMP SURFACE MOUNT STRIP CONCEALED IN HEADBOARD 1 -$- TB -1 LAMP FOOTBOARD LAMP PROVIDED BY SC INSTALLED BY GC. LAMP HAS CORD (NO PLUG). GC TO RUN CORD THROUGH CONDUIT IN FOOTBOARD FIXTURE AND INSTALL PLUG ON CORD. ANCHOR LAMP TO FOOTBOARD USING CLAMP AND SET SCREWS PROVIDED WITH FIXTURE. 4 LT CUSTOM FIXTURE STONEGATE DESIGNS 5 LH 0063 THREE 100W A LAMPS MOUNT AT 86" AFF ® E EXIT SIGN CARPENTER CEWXLDRU INCLUDED UNIVERSAL LED EXIT SIGN, WHITE. DETERMINE NUMBER OF FACES (1 OR 2) PER PLAN El EMERGENCY LIGHT CARPENTER BKO INCLUDED UNIVERSAL EMERGENCY LIGHT CEILING SYMBOLS PROVIDED AND INSTALLED BY GC EXHAUST FAN NUTONE Q 1 T110H / * LIGHT IN MET IIAWINGSM TO CONTROL LIGHT AND FAN. SWITCH 1Q 0 SPEAKER ATLAS FAP -40T W/ IW2 -22GA COPPER ALTERNATE SPEAKER: TWISTED WIRE AUDIO SOURCE IC8S CABLE TO RUN FROM SPEAKERS TO STOCKROOM LOCATION PLUS 10'COILED FOR FINAL HOOKUP GENERAL NOTES A. ALL LIGHT FIXTURES WITH LAMPS PROVIDED BY TENANT'S VENDOR. INSTALLED AND CONNECTED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. B. C. COORDINATE EXACT FIXTURE LOCATION WITH ARCHITECTURAL REFLECTED CEILING PLAN. TYPE "T1" TRACK TO BE MOUNTED TO CEILING ON GRID SYSTEM. SEE LIGHTING PLAN THIS SHEET AND ARCHITECTURAL DETAILS. D. AFTER MERCHANDISE FIXTURES ARE IN PLACE, ELECTRICAL CONTRACTOR TO CLEAN AND AIM ALL LIGHT FIXTURES AS DIRECTED BY OWNER. E. ELECTRICAL CONTRACTOR IS TO PROVIDE TEMPORARY LIGHTING WITHIN THE SPACE. F. 'NL' INDICATES NIGHT LIGHT, 'EM' INDICATES EMERGENCY LIGHT. G. LIGHTING FIXTURE BALLASTS SHALL BE HIGH POWER FACTOR CBM LABELED. NOTES FOR THIS DRAWING ELECTRICAL SERVICE LOCATION. SEE RISER DIAGRAM AND PANELBOARD SCHEDULES. SEE SHEET E2.0 O2 SWITCH LOCATION. SEE SWITCHBANK DETAIL 2/E1.0. SEE SHEET E1.0 FOR LIGHTING CIRCUITS, FIELD VERIFY. O LIGHT SWITCH TO CONTROL BOTH FAN AND LIGHT. MAKE CONNECTION TO FAN, PROVIDED AND INSTALLED BY OTHERS ON ROOF. COORDINATE WITH MECHANICAL. CENTER OF SWITCH AT 45" A.F.F. O4 CIRCUIT EMERGENCY, EXIT, AND NIGHT LIGHTING AHEAD OF SWITCH. • ELECTRICAL CONTRACTOR SHALL FISH LAMP CORD THROUGH CONDUIT IN FOOTBOARD, ATTACH PLUG TO CORD (INCLUDED WITH LAMP), AND ATTACH LAMP TO FOOTBOARD. TB1 LAMPS PLUG INTO RECEPTACLE AT HEADBOARD. O6 ALL STOREFRONT DISPLAY ZONE / SIGNAGE LIGHTING TO BE CONTROLLED VIA TIMECLOCK. REVISIONS No changes shall be made to the of scope of work without prior approval Tukwila Building Division. NOTE: Revisions d �u e submittal and may include additional plan review fees FILE PY Permit No. Pfar review approval is subject to errors Approval of construction documents ordinance. Receipt the violation of any of approved Field , and .. ='' / d/4; BY difr Date: City of Tukwila BUILDING DIVISION LIGHTING PLA\ 1/4" = REVIEWED FOR CODE COMPLIANCE NFPA70 °NE SEPARATE PERMIT REQUIRED FOR: tf Machanica) liElectrical Plumbing If Gas Piping City of Tukwila BUIL nimr, nn,�s�,,. MAY 1 5 2008 la 12 [6 w 8 LDING DM I 0 N Of Tukwila TRACK LIGHTING INDICATES FIXTURE TYPE O x INDICATES CIRCUIT NUMBER INDICATES SWITCH CONTROL SALES LIGHTING SALES LIGHTING ACCENT LIGHTING STOCK LIGHTING SWITI, H BA\ K DETAIL NO SCALE RECEIVED CITY OF TUKWILA MAY 0 8 2008 PERMIT CENTER �I,D�-53g IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS PLEASE CALL THE ELECTRICAL DESIGNER. DESIGNER: PATRICK DAVITT 612 -465 -7677 OR SUPERVISOR: RON MATHESON 612-465-7673 CONCEPT BY: L&M ASSOCIATES LTD [1 2 ct I z Dunham Associates, Inc. 0 Q 0 w >- W J J a n 0 0 FAx 612.465.7551 PHONE 612.465.7550 i • , O a ❑W w z x z L z W - as CC 9, 0 za w ❑ Q wu- d unhameng.com mechanical + electrical consulting engineering 02007 LAM ASSOCIATES, LTD. ALL RIGHTS RESERVED w z D SELECT COMFORT Z N w t z� a� zz O2 Z_ Lu I— 0 o>- (D CL 1- 0 w 0 a J ¢ CC cc - O pC Z LL w O w 2 O w O I— O • H -wOu) w O O M 00 no 0 PROJECT NO. 0 0 0 a 0 0 0 a 1- w 1— 0 CO cV tV cV CO z 0 w J or w a_ 1— z z w 1- w 0_ PER TENANT PER ARCH CCC DOCUMENT DATE 27 AUGUST 2007 DRAWN BY w 1— 0 SUED FOR CHECKED BY 1- w w 1 O w 1- 1- NOTES FOR THIS DRAWING O INTERCEPT AND EXTEND LANDLORD'S TELEPHONE CONDUIT TO TELEPHONE BACKBOARD LOCATION. IF NOT EXISTING, CONDUIT SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR. VERIFY EXACT DISTANCE AND ROUTING IN THE FIELD. COORDINATE WITH LANDLORD'S REPRESENTATIVE. O2 NEW WATER HEATER: 4.16KW, 208V, 1- PHASE, FURNISHED AND INSTALLED BY OTHERS. VERIFY REQUIREMENTS PRIOR TO ROUGH -IN. PROVIDE ALL REQUIRED CONNECTIONS. ELECTRICAL CONTRACTOR TO MOUNT FLUSH DUPLEX RECEPTACLE IN SHOW WINDOW CEILING. CEILING RECEPTACLE IS TO BE 6" FROM FACE OF GLASS IN SOFFIT(S). COLOR: BEIGE /IVORY. COORDINATE LOCATION WITH ARCHITECTURAL REFLECTED CEILING PLAN. 0. PROVIDE TIME SWITCH: PARAGON MODEL 7000 - SERIES OR EQUAL WITH 7 DAY, 24 HOUR SCHEDULING FORMAT, MIN. (4) N.O. 20 AMP 120 VOLT CONTACTS VOLT COIL AND SPRING WOUND RIDE - THROUGH. SWITCH SHALL CONTROL STOREFRONT AND SIGN LIGHTING OR CONTACTOR(S) AS INDICATED. OSPEAKERS AND WIRING PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR, FIELD VERIFY. . PROVIDE PANELS AS REQUIRED. SEE RISER DIAGRAM ON SHEET E3.0 FOR MORE INFORMATION. O NEW VAV /DUCT HEATER: 480V, 3- PHASE, S.OKW, 1/2 HP FAN. PROVIDE 30A, DISCONNECT AT UNIT. MAKE FINAL CONNECTION, COORDINATE WITH MECHANICAL. <> PROVIDE (2) SINGLE GANG OUTLET BOXES, FOR TELEPHONE /DATA OUTLETS, (2) 3/4" CONDUITS WITH PULL WIRE STUBBED INTO ACCESSIBLE CEILING SPACE FOR DATA LINE. MOUNT 4' -10" FROM BACK WALL. FIELD VERIFY ALL DEVICE LOCATIONS PRIOR TO ROUGH -IN WITH OWNER'S FIELD REPRESENTATIVE. SEE DETAIL 2/E2.0. O9 ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL (2 -GANG) J -BOX FOR SOUND SYSTEM. SOUND AMPLIFIER BY TENANT, VERIFY LOCATION. <> ELECTRICAL CONTRACTOR SHALL MOUNT OUTLETS RECESSED IN WALL. FIELD VERIFY ALL DEVICE LOCATIONS PRIOR TO ROUGH -IN WITH OWNER'S FIELD REPRESENTATIVE. SEE DETAIL 2/E2.0. DO NOT SURFACE MOUNT. 11 J -BOX W/ DISC. SW., PER NEC ART. 600, ABOVE ACCESSIBLE CEILING FOR CONNECTION TO STOREFRONT SIGN. 12 THERMOSTAT, COORDINATE WITH MECHANICAL. 13 PROVIDE RECEPTACLES MOUNTED AT 18" A.F.F. PROVIDE SEPARATE CIRCUIT FOR EACH DUPLEX RECEPTACLE, CIRCUITS AS INDICATED. <> PROVIDE FLOOR BOX WITH RECEPTACLE. VERIFY COVER WITH OWNER/ ARCHITECT. PROVIDE SEPARATE CIRCUITS TO EACH RECEPTACLE AS INDICATED. VERIFY CORING /TRENCHING REQUIREMENTS WITH LANDLORD'S OPERATIONS MANAGER PRIOR TO BID. ELECTRICAL CONTRACTOR TO VERIFY ALL DIMENSIONS WITH G.C. AND OWNER'S FIELD REPRESENTATIVE PRIOR TO ROUGH -IN. FAILURE TO DO 50 WILL BE SOLELY AT THE CONTRACTOR'S EXPENSE TO RELOCATE. (FLUSH FLOOR BOX SHALL BE STEEL CITY OR APPROVED EQUAL.) <> PROVIDE RECEPTACLE AT CEILING FOR SCENT DISPENSOR. VERIFY EXACT LOCATION WITH OWNER'S REPRESENTATIVE IN THE FIELD. <> PROVIDE JUNCTION BOX CENTERED IN WALL BEHIND CASHWRAP AT 6' -7" AFF FOR SIGN PANEL. SIGN TO BE CONTROLLED BY TIMECLOCK. PROVIDE JUNCTION BOX IN SOFFIT FOR CONNECTION TO "NUMBER WALL" SIGN. VERIFY EXACT LOCATION AND REQUIREMENTS WITH SIGN SUPPLIER /INSTALLER. CONTROL VIA TIMECLOCK. IN T•LL R CE TA LE AN I JUNG ION :OX ON E U DE -SITE IF TH 12' -O" CEILING FOR PROJECTOR. PROVIDE 3/4" DATA CONDUIT AND C TI IVD P •Y R LO ATISN •T ."IG T -SIZE IE NISI► G L. • PROVIDE RECEPTACLE AND 2 -GANG JUNCTION BOX WITH SINGLE -GANG MUD RING @18" AFF. PROVIDE 1" CONDUIT WITH PULL STRING STUBBED FROM JUNCTION BOX TO ABOVE ACCESSIBLE CEILING INSIDE THE STORE. • PROVIDE JUNCTION BOX IN WALL 18" AFF ADJACENT TO RECEPTACLES. JUNCTION BOX TO BE USED FOR CONNECTION TO "51" FIXTURES IN HEADBOARDS. SEE SHEET E1.0 FOR MORE INFORMATION. A GENERAL NOTES A. REFER TO ARCHITECTURAL DETAILS FOR COORDINATION OF ALL ELECTRICAL DEVICES. B. REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF MECHANICAL EQUIPMENT. C. COORDINATE WITH LANDLORD'S FIRE ALARM SYSTEM CONTRACTOR REQUIREMENTS FOR FIRE ALARM SYSTEM: SMOKE DETECTORS, HORN /STROBES, STROBES, ZONE MODULES, MONITORING MODULES AND ALL ASSOCIATED WORK AND COSTS INVOLVED THEREIN. D. AN EQUIPMENT GROUNDING CONDUCTOR IS REQURIED IN ALL CONDUIT RUNS PER LOCAL CODE. PROVIDE 1 # 8 GROUND FOR EACH N UL 5 0 :W I II •T D E. ALL DUPLEX RECEPTACLES, LIGHT SWITCHES AND COVER- PLATES SHALL BE WHITE. PROVIDE ORANGE IG RECEPTACLES. LANDLORD NOTES A. STOREFRONT SIGNAGE AND LIGHTING TIME CLOCKS SHALL BE SET TO MALL'S OPERATING HOURS. B. LANDLORD WILL PROVIDE A COMMUNICATION CABLE TRAY LOCATED IN THE UTILITY CORRIDOR FOR TENANT'S USE. NO CONDUIT WILL BE PROVIDED. LANDLORD WILL PROVIDE A COMMUNICATIONS TERMINAL BOARD WITHIN EACH LANDLORD ELECTRICAL ROOM. TENANT SHALL PROVIDE AND INSTALL A COMPLETE TELEPHONE SERVICE SUPPORT FACILITIES AS REQUIRED BY THE SERVING TELEPHONE COMPANY. ALL TENANT TELEPHONE SHALL BE CONTAINED WITHIN THE TENANT'S SPACE. TENANT SHALL PROVIDE PLENUM RATED WIRE FROM THE TELEPHONE ROOM TO THE TENANT'S TELEPHONE EQUIPMENT WITHIN THE DEMISED PREMISES UTILIZING THE LANDLORD SUPPLIED CABLE TRAY. ANY CORRIDOR WALL PENETRATIONS WILL NEED TO BE FIRE CAULKED AS REQUIRED. C. LANDLORD SHALL FURNISH AND INSTALL ONE FIRE ALARM JUNCTION BOX INSIDE THE DEMISED PREMISES FOR EACH TENANT'S USE IN CONNECTING THEIR INDIVIDUAL FORE ALARM SYSTEMS OR COMPONENTS. TENANT SHALL FURNISH AND INSTALL ALL NECESSARY INITIATION DEVICES, ANNUNCIATION DEVICES AND CONTROLS ARE REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. TENANT SHALL CONTRACT WITH LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR FOR DESIGN, PROGRAMMING, AND FINAL CONNECTIONS TO LANDLORD'S FIRE ALARM SYSTEM AT TENANT'S EXPENSE. TENANT SHALL USE ONLY LANDLORD'S DESIGNATED FIRE ALARM CONTRACTOR SPECIFIED EQUIPMENT TO ENSURE COMPATIBILITY WITH LANDLORD'S FIRE ALARM SYSTEM. PANEL L PANEL H TIMECLOCK L -16 % PHONE LINES 1 & 2 OF CW ACCESS PANEL 20" OF CW ACCESS PANEL DEDICATED POWER CIRCUITS L2 & L4 D 0 0 PHONE LINES 3 & 4 1" NON- DEDICATED POWER CIRCUIT L6 CAST NTS WRAP 3 -TAIL Station 1 Wallplate L1L2 Phone ,1 L3 PC 11 Modem L2 Fox DSL DSL Line Station 2 Wallplate L1 L2 R1 -14 Phone #2 L.3 PC A2 Modem L2 Fax DSL 1 DSL Line WIRING GUIDELINES FOR TELEPHONE * EACH STORE SHOULD HAVE A DEMARC SOMEWHERE IN THE MALL OUTSIDE OF THE SUITE. THAT DEMARC 1S THEN EXTENDED INTO THE SUITE AND TERMINATED TO WHAT IS CALLED THE IN -STORE DEMARC. * TYPICALLY 4 PAIR ARE TO THE DEMARC: THREE FOR POTS VOICE LINES AND A SEPARATE PAIR WHICH IS NEEDED FOR SOME DEDICATED DSL CIRCUITS. * THE COUNTER UNIT WHERE THE PC 15 LOCATED 15 REFERRED TO AS THE "CASH WRAP". STORES HAVE THREE PHONE LINES PLUS A DSL UNE THAT ALL RUN UP TO THE CASH WRAP. * THERE WILL BE 2 "STATIONS' AT THE CASH WRAP. EACH WILL HAVE A PC AND A 2 -LINE, RJ -14 STYLE PHONE. A SEPARATE FACE PLATE AND SET OF JACKS SHOULD BE INSTALLED FOR EACH STATION. * THE FAX WILL SHARE LINE 2. * BOTH PCs WILL SHARE LINE 3 FOR OCCASIONAL MODEM USE. LABEUNG * PLEASE LABEL ALL JACKS WITH THE APPROPRIATE PHONE NUMBERS. * USE A MARKER AND WRITE THE NUMBERS DIRECTLY ON THE FACEPLATE BELOW EACH CONNECTOR. LINE 1 NUMBER (1_1)• LINE 2 NUMBER (L2)• LINE 2 NUMBER (L2): _ _____ TFLFPHO NTS \G RJ -14 PINOUT RING 2 TIP 2 RING 1 - -TIP 1 STORE PHONE SETS ARE 2 -LINE ANALOG SETS. THEY USE AN RJ -14 CONNECTOR AS SHOWN ABOVE POWER PEA\ REVIEWED MPIsANCE CODE CO NFPA 70 ° NEC MAY 1. 5 NOB O�y Of Tukwila B .`ILD'IN .. D`... SI N: 1/4" = 1' —O" IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS PLEASE CALL THE ELECTRICAL DESIGNER. DESIGNER: PATRICK DAVITT 612- 465 -7677 OR SUPERVISOR: RON MATHESON 612- 465 -7673 O DEDICATED > NON- DEDICATED POWER POWER ORANGE IVORY CIRCUIT 19 CIRCUIT 21 PRESSJR L, CABI NTS \ET NAPPING DETAIL CONCEPT BY: Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 H Minneapolis. Minnesota 55402 -1546 0 cc w 5 w 1 7 N. 0 a 0 FA% 612.465.7551 PHONE 612.465.7550 4 L 1- 0 cn W W z z = z� ui a3 0_ M za LU ❑ < wti- a 0) c v rn N 0 U W „ i. a) m 0) - C co s 0 d E 952 -944 -7576 dunhameng.com © 2007 L &M ASSOCIATES, LTD. ALL RIGHTS RESERVED INSTALL J -BOX FOR LINE 3 AND DSL LINE. ORANGE DEDICATED RECEPTICLE LEFT SIDE, NON- DEDICATED RECEPTICLE RIGHT SIDE. SEE 4/E2.0 SEE SHEET A5.0 FOR MOUNTING HEIGHT. PRESS,RE CAB \ -T 3 VAPPI -TAIL NTS \ C RECEIVED CITY of TuKVnLA MAY 0 8 2[ 08 PERMIT CENTER PROJECT SELECT COMFORT SOUTHCENTER MALL SUITE # 1005 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 PROJECT NO. 408865 -13 ELECTRICAL LEGEND ALL SYMBOLS DO NOT NECESSARILY APPLY a a 0 0_ CI a MOUNTING HGT. TO CENTERLINE MOUNTING HGT. TO CENTERLINE SYMBOL DESCRIPTION UNLESS OTHERWISE NOTED SYMBOL DESCRIPTION UNLESS OTHERWISE NOTED 0 CEIUNG OUTLET 1 TELEPHONE OUTLET - 4" SQ. W /PLASTER RING 18" ;PER TENANT -0 WALL OUTLET SEE DRAWINGS -0 WIRED JUNCTION BOX SEE DRAWINGS B DATA OUTLET - 4" SQ. W /PLASTER RING 18" ta CEILING MOUNTED EXIT LIGHT VI FIRE ALARM AUDIO /VISUAL SIGNAL DEVICE 96" DUPLEX RECEPTACLE, 3 WIRE GRD. TYPE 18" DUCT MTD. SYSTEM SMOKE DETECTOR F W/ REMOTE INDICATORS QUADRAPLEX RECEPTACLE 18" 0 JUNCTION BOX AS REQUIRED $ TOGGLE SWITCH. SINGLE POLE 48" DUPLEX RECEPTACLE AT STOREFRONT CEILING MTD. $3 $4 TOGGLE SWITCH, 3 -WAY, 4 -WAY 48" O CEILING SPEAKER CEILING MTD. 10 SAFETY SWITCH AS REQUIRED E. TIME CLOCK AS REQUIRED — ELECTRIC PANEL 6' -0° TO TOP UGHTING CONTACTOR AS REQUIRED C PHONE LINES 1 & 2 OF CW ACCESS PANEL 20" OF CW ACCESS PANEL DEDICATED POWER CIRCUITS L2 & L4 D 0 0 PHONE LINES 3 & 4 1" NON- DEDICATED POWER CIRCUIT L6 CAST NTS WRAP 3 -TAIL Station 1 Wallplate L1L2 Phone ,1 L3 PC 11 Modem L2 Fox DSL DSL Line Station 2 Wallplate L1 L2 R1 -14 Phone #2 L.3 PC A2 Modem L2 Fax DSL 1 DSL Line WIRING GUIDELINES FOR TELEPHONE * EACH STORE SHOULD HAVE A DEMARC SOMEWHERE IN THE MALL OUTSIDE OF THE SUITE. THAT DEMARC 1S THEN EXTENDED INTO THE SUITE AND TERMINATED TO WHAT IS CALLED THE IN -STORE DEMARC. * TYPICALLY 4 PAIR ARE TO THE DEMARC: THREE FOR POTS VOICE LINES AND A SEPARATE PAIR WHICH IS NEEDED FOR SOME DEDICATED DSL CIRCUITS. * THE COUNTER UNIT WHERE THE PC 15 LOCATED 15 REFERRED TO AS THE "CASH WRAP". STORES HAVE THREE PHONE LINES PLUS A DSL UNE THAT ALL RUN UP TO THE CASH WRAP. * THERE WILL BE 2 "STATIONS' AT THE CASH WRAP. EACH WILL HAVE A PC AND A 2 -LINE, RJ -14 STYLE PHONE. A SEPARATE FACE PLATE AND SET OF JACKS SHOULD BE INSTALLED FOR EACH STATION. * THE FAX WILL SHARE LINE 2. * BOTH PCs WILL SHARE LINE 3 FOR OCCASIONAL MODEM USE. LABEUNG * PLEASE LABEL ALL JACKS WITH THE APPROPRIATE PHONE NUMBERS. * USE A MARKER AND WRITE THE NUMBERS DIRECTLY ON THE FACEPLATE BELOW EACH CONNECTOR. LINE 1 NUMBER (1_1)• LINE 2 NUMBER (L2)• LINE 2 NUMBER (L2): _ _____ TFLFPHO NTS \G RJ -14 PINOUT RING 2 TIP 2 RING 1 - -TIP 1 STORE PHONE SETS ARE 2 -LINE ANALOG SETS. THEY USE AN RJ -14 CONNECTOR AS SHOWN ABOVE POWER PEA\ REVIEWED MPIsANCE CODE CO NFPA 70 ° NEC MAY 1. 5 NOB O�y Of Tukwila B .`ILD'IN .. D`... SI N: 1/4" = 1' —O" IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS PLEASE CALL THE ELECTRICAL DESIGNER. DESIGNER: PATRICK DAVITT 612- 465 -7677 OR SUPERVISOR: RON MATHESON 612- 465 -7673 O DEDICATED > NON- DEDICATED POWER POWER ORANGE IVORY CIRCUIT 19 CIRCUIT 21 PRESSJR L, CABI NTS \ET NAPPING DETAIL CONCEPT BY: Dunham Associates, Inc. 50 South Sixth Street / Suite 1100 H Minneapolis. Minnesota 55402 -1546 0 cc w 5 w 1 7 N. 0 a 0 FA% 612.465.7551 PHONE 612.465.7550 4 L 1- 0 cn W W z z = z� ui a3 0_ M za LU ❑ < wti- a 0) c v rn N 0 U W „ i. a) m 0) - C co s 0 d E 952 -944 -7576 dunhameng.com © 2007 L &M ASSOCIATES, LTD. ALL RIGHTS RESERVED INSTALL J -BOX FOR LINE 3 AND DSL LINE. ORANGE DEDICATED RECEPTICLE LEFT SIDE, NON- DEDICATED RECEPTICLE RIGHT SIDE. SEE 4/E2.0 SEE SHEET A5.0 FOR MOUNTING HEIGHT. PRESS,RE CAB \ -T 3 VAPPI -TAIL NTS \ C RECEIVED CITY of TuKVnLA MAY 0 8 2[ 08 PERMIT CENTER PROJECT SELECT COMFORT SOUTHCENTER MALL SUITE # 1005 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 PROJECT NO. 408865 -13 m a a 0 0_ CI a 1 DATE r- 0 4 2/26/08 3/20/08 z 0 w cc PER LL, ARCH. ;PER TENANT PER TENANT DOCUMENT DATE 27 AUGUST 2007 DRAWN BY W 1- Q ISSUED FOR 0 CHECKED BY 1- W 1 U) 0 N w J 1- POWER PLAN E L E C T R I C A L S P E C I F I C A T I O 16000 - GENERAL PROVISIONS 0.01 PERFORMANCE: ELECTRICAL CONTRACTOR SHALL PERFORM ALL WORK SPECIFIED, INDICATED AND REQUIRED UNLESS NOTED, INCLUDING FINAL CONNECTIONS, IN A WORKMANLIKE MANNER USING WORKERS SKILLED AND EXPERIENCED IN THE THE TRADE. 0.02 SITE EXAMINATION: EXAMINE SITE BEFORE BIDDING. CLAIMS FOR EXTRAS RESULTING FROM LACK OF KNOWLEDGE OF SITE CONDITIONS SHALL NOT BE ALLOWED OR APPROVED. 0.03 JOB SITE CONDITIONS: ACCEPT SOLE AND COMPLETE RESPONSIBILITY FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFROMANCE OF WORK. 0.04 FULL FUNCTION: PROVIDE ALL MINOR ITEMS NECCESARY FOR COMPLETE AND FULLY FUNCTIONAL INSTALLATION. 0.05 ADMINISTRATION: PROVIDE EVIDENCE OF LICENSING, BONDING, AND INSURANCE, AND PERFORM OTHER ADMINISTRATIVE FUNCTIONS, AS REQUIRED. 0.06 PERMITS: PROCURE AND PAY FOR ALL REQUIRED PERMITS AND SERVICE CHARGES. 0.07 COORDINATION: CONFIRM TO GENERAL CONSTRUCTION CONTRACT DOCUMENTS EXCEPT AS MODIFIED HERON. REFER ALSO TO STRUCTURAL AND MECHANICAL CONTRACT DOCUMENTS, COORDINATE ALL WORK WITH OTHER TRADES. 0.08 ROOF PENETRATIONS: COORDINATE WITH LANDLORD. 0.09 MECHANICAL SUBSTITUTIONS: INVOICE MECHANICAL CONTRACTOR, NOT TENANT FOR COSTS INCURRED DUE TO SUBSTITUTION OF MECHANICAL EQUIPMENT HAVING ELECTRICAL REQUIREMENTS DIFFERING FROM THOSE INDICATED. 0.10 ADJUSTMENTS: MAKE MINOR ADJUSTMENTS TO WORK WHERE REQUESTED BY TENANT, WHEN SUCH ADJUSTMENTS ARE NECESSARY TO PROPER OPERATION AND WITHIN THE INTENT OF THE CONTRACT. 0.11 REFERENCE STANDARDS: COMPLY WITH NEC, AND APPLICABLE STANDARDS OF NFPA, ANSI, NEMA, AND UL, EXEPT AS SUPERSEDED BY LOCAL AUTHORITY. CONFORM WITH CONTRACT DOCUMENTS WHERE THEY EXCEED CODE MINIMUM REQUIREMENTS. 012 LOCAL REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF LOCAL CODES, LANDLORD, SERVING UTILITY, AND THE LOCAL AUTHORITY HAVING JURISDICTION. SECURE APPROVAL OF INSTALLLATION BY LANDLORD, LOCAL AUTHORITY, AND OTHERS AS REQUIRED. 0.13 SCHEDULE: ORDER EQUIPMENT WITHIN 5 DAYS OF RECEIPT OF CONTRACT TO MAINTAIN CONSTRUCTION SCHEDULE. 0.14 TEMPORARIES: PROVIDE ALL TEMPORARY SERVICE, LIGHTING AND POWER FOR ALL TRADES AS REQUIRED. REMOVE ALL TEMPORARIES BY THE TIME OF PROJECT COMPLETION. 0.15 MATERIALS AND EQUIPMENT: PROVIDE NEW, UL LISTED, COMMERCIAL GRADE MATERIALS, DEVICES, EQUIPMENT, AND FIXTURES, SUITABLE FOR ENVIRONMENT. REUSE EXISTING ONLY WHEN COMPLIANT WITH THE CONTRACT DOCUMENTS, IN GOOD CONDITION, AND APPROVED BY THE ENGINEER. COMPLY WITH CURRENT CODES. 0.16 INSTALLATION: INSTALL ALL MATERIALS, EQUIPMENT AND SYSTEMS IN FULL ACCORD WITH MANUFACTURERS' RECOMMENDATIONS. 0.17 COMMISSIONING: THOROUGHLY TEST AND DEMONSTRATE PROPER OPERATION OF ALL SYSTEMS AND EQUIPMENT FURNISHED OR INSTALLED UNDER THIS CONTRACT, VERIFY PROPER MOTOR ROTATION OF ALL EQUIPMENT. 0.18 0 & M MANUALS: AT COMPLETION OF PROJECT, PROVIDE TO TENANT ALL OPERATING AND MAINTENANCE MANUALS AND INFORMATION FOR MATERIAL EQUIPMENT AND SYSTEMS INSTALLED UNDER THIS CONTRACT. 0.19 CORRECTIVE PERIOD: PROVIDE A CORRECTIVE PERIOD FROM DATE OF FINAL ACCEPTANCE OF NOT LESS THAN ONE (1) YEAR FOR THE ENTIRE INSTALLATION. DURING WHICH PERIOD UNCONDITIONALLY MAKE GOOD ANY DEFECTS IN MATERIALS OR WORKMANSHIP WITHOUT COST TO TENANT. 0.20 DRAWINGS ARE DIAGRAMMTIC: VERIFY ALL DIMENSIONS AND LENGTHS, AND ADJUST EQUIPMENT AND RACEWAY LOCATIONS TO AVOID CONFLICTS AND OTHER CONSTRUCTION. 0.21 DOCUMENT PRIORITY: DRAWING INDICATIONS AND NOTATIONS SUPERSEDE THESE SPECIFICATIONS. 0.22 RATINGS: REFER TO DRAWINGS AND SCHEDULES FOR ADDITIONAL RATINGS AND REQUIREMENTS. 0.23 PROJECT REQUIREMENTS: REFER TO DRAWING FOR PARTICULAR PROJECT REQUIREMENTS, AS NOT ALL ITEMS SPECIFIED MAY BE REQUIRED FOR THIS PROJECT. 0.24 DOCUMENT ERRORS: NOTIFY THE ENGINEER OF ERRORS, DISCREPANCIES OR OMISSIONS BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, FAILING SUCH NOTICE, BE RESPONSIBLE FOR CORRECTING SAME. 0.25 CERTIFICATION: PROFESSIONAL ENGINEER CERTIFICATION OF THESE DOCUMENTS DOES NOT EXTEND TO STANDARDIZED DESIGN OR INSTALLATION GUIDELINES PREPARED BY OTHERS AND REQUIRED BY A THIRD PARTY TO BE INCLUDED HEREON. 0.26 DEFINITIONS: THE TERMS LISTED BELOW ARE DEFINED AS FOLLOWS WHEN USED IN DIVISION 16 AND ONLY DIVISION 16. A. FURNISH: OBTAIN, COORDINATE, SUBMIT THE NECESSARY DRAWINGS, DELIVER TO THE JOB SITE IN NEW CONDITION AND GUARANTEE. B. INSTALL: RECEIVE AT THE JOB SITE, UNLOAD, STORE, SET IN PLACE, CONNECT, PLACE IN OPERATION AND GUARANTEE. C. PROVIDE: FURNISH AND INSTALL. D. REMOVE: REMOVE INSTALLATION BACK TO NEXT REMAINING POINT OF USE. 0.27 IDENTIFICATION AND LABELING: PROVIDE IDENTIFICATION AND NAMEPLATES ON PANELBOARDS, DISCONNECT SWITCHES AND CONTROLS WITHIN THE TENANT SPACE. NAMEPLATES SHALL BE ENGRAVED LAMINATED PLASTIC, WHITE LETTERS ON BLACK BACKGROUND. LLIIERS FOR PANELBOARDS AND SWITCHBOARDS SHALL BE 1/4" HIGH. LETTER HEIGHTS FOR ALL OTHER NAMEPLATES SHALL BE 1/8" HIGH. 16100 - MATERIALS 1.01 RACEWAY: CONTINUOUS SYSTEM, 1/2" MINIMUM EMT EXCEPT: 3/4" MINIMUM RNC WITH GROUND CONDUCTOR WHERE EMBEDDED IN CONCRETE OR MASONRY; 3/4" MINIMUM GALVANIZED RMC OR IMC WHERE EXPOSED TO WEATHER (ALSO PERMITTED WHERE EMBEDDED IN CONCRETE OR MASONRY); AND FMC (OR LTFMC IF WET LOCATION) FOR SHORT FINAL CONNECTIONS TO LIGHTING FIXTURES, TRANSFORMERS, AND MECHANICAL EQUIPMENT. 1.02 IG RACEWAY: PROVIDE SEPARATE RACEWAY SYSTEM FOR IC CIRCUITS. 1.03 RACEWAY INSTALLATION: CONCEAL RACEWAY IN FINISHED SPACES. ROUTE SQUARE WITH BUILDING LINES AND SUPPORT PER NEC. DO NOT ATTACH TO OR PENETRATE HVAC DUCTS. MAINTAIN HEADROOM AND EQUIPMENT AND FLUE CLEARANCE. FIRE /SMOKE - SEAL PENETRATIONS OF RATED CONSTRUCTION. 1.04 RACEWAY ADJUSTMENTS: WHERE INDIVIDUAL HOME RUNS ARE SHOWN FOR CLARITY, CIRCUITS MAY BE COMBINED INTO COMMON CONDUITS. CONDUCTORS SIZES SHALL BE INCREASED TO ACCOMDATE APPROPRIATE CONDUCTOR DERATING FACTORS PER NEC. 1.05 WIRE: TYPE THHN, COPPER ONLY, 12AWG MINIMUM, STRANDED FOR 8 AWG AND LARGER, LV WIRING, FOR EMERGENCY LIGHTING 10AWG MINIMUM. USE OF ALUMINUM CONDUCTORS SHALL NOT BE ALLOWED. 1.06 COLOR CODE: COLOR CODE ENTIRE WIRING SYSTEM FROM SERVICE DISCONNECT OR TRANSFORMER THROUGHOUT ALL BRANCH CIRCUITS AS FOLLOWS: 120/208 Y VOLTS 277/480 Y VOLTS PHASE A B C NEUTRAL GROUND COLOR BLACK RED BLUE WHITE GREEN PHASE COLOR A BROWN C ORANGE YELLOW NEUTRAL NATURAL GRAY GROUND GREEN 1.07 WIRE SIZE: WHERE WIRES ARE SIZED PER 60 DEC. C TEMPERATURE RATING FOR SIZES UP TO 1 AWG, SUBJECT TO COMPLIANCE WITH EQUIPMENT UL LISTING, AND APPROVAL OF LOCAL AUTHORITY AND ENGINEER, SUCH WIRES MAY BE REDUCED TO 75 DEG. C RATED SIZE, WITH RACEWAY SIZE ADJUSTED ACCORDINGLY. WIRE SIZE PER 90 DEG. C TEMPERATURE RATING IS NOT APPROVED. 1.08 VOLTAGE DROP: FOR CONDUCTORS SIZED PER NEC ON DRAWINGS, INCREASE SIZE BY NUMBER OF STANDARD SIZES SHOWN IN TABLE TO COMPENSATE FOR VOLTAGE DROP. CONTACT ENGINEER FOR ASSISTANCE IF CIRCUIT LENGTH FROM SOURCE TO LOAD EXCEEDS MAXIMUMS SHOWN: INCREASE # CCT VOLTS /PH CCT LENGTH FT. CONDUIT SIZES 120/1 120/1 208/3 OR 277/1 208/3 OR 277/1 75 -150 150 -200 150 -200 200 -250 1 2 1 2 1.09 TYPE MC CABLE: MC CABLE EQUIPPED WITH A GREEN INSULATED GROUND PERMITTED FOR BRANCH CIRCUITS IN CONCEALED LOCATIONS ONLY SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY. .10 SPLICES: SPLICE ONLY IN ACCESSIBLE JUNCTION BOXES, USING WIRENUT CONNECTORS FOR 8 AWG AND SMALLER, OR MECHANICAL COMPRESSION CONNECTORS WITH INSULATION KIT FOR 6 AWG AND LARGER. 1.11 BOXES: NEMA OS1 IN INTERIOR DRY LOCATIONS, CAST WEATHERPROOF TYPE IN WET LOCATIONS. 1.12 WALL SWITCHES: FED SPEC W -S -896, AC GENERAL USE, 20 AMP, 120 -277 VOLT, TOGGLE HANDLE. INSTALL 48" A.F.F TO CENTER. 1.13 WALL RECEPTACLES: FED SPEC W -C -596, NEMA 5 -20R CONFIGURATION OR AS REQUIRED. PROVIDE IG (ISOLATED GROUND) AND GFCI /WP (GROUND -FAULT CIRCUIT INTERRUPTER) RECEPTACLES WHERE APPROPRIATE OR INDICATED. INSTALL 18" A.F.F TO CENTER, OR AS INDICATED. 1.14 WALL PLATES: SMOOTH PLASTIC, WHITE. 1.15 WALL DEVICE AND PLATE COLOR: WHITE. PROVIDE ORANGE IG RECEPTACLES. 1.16 MANUFACTURED WIRING SYSTEMS: PERMITTED FOR BRANCH CIRCUITS SUBJECT TO APPROVAL OF TENANT, LANDLORD, AND LOCAL AUTHORITY. 1.17 GROUNDING: PROVIDE CONTINUOUS, PERMANENT, AND EFFECTIVE GROUNDING SYSTEM. GROUND SEPARATELY DERIVED SYSTEMS IN ACCORDANCE WITH NEC. 16400 - EQUIPMENT 4.01 DISCONNECT SWITCH: NEMA KS1, GENERAL DUTY, 3 -POLE, S/N IF NEUTRAL IS PRESENT. NEMA 3R ENCLOSURE IF OUTDOORS. LOCK -OFF, NON- FUSIBLE UNLESS INDICATED WITH FUSES. 4.02 DRY -TYPE TRANSFORMER: REUSE EXISTING OR PROVIDE NEW PER THE FOLLOWING: NEW NEMA ST20, 480: 208Y120 CONNECTED, 115 DEGREE RISE, KVA RATING AS INDICATED. INSTALL USING VIBRATION ISOLATORS. FOR JURISTRICTIONS WITH REQUIREMENTS FOR ENERGY EFFICIENT TRANSFORMERS, PROVIDE NEMA TYPE-TP1, 150' RISE. 4.03 PANELBOARDS: REUSE EXISTING IF APPLICABLE AND STILL MEETS CODE REQUIREMENTS OR PROVIDE NEW PER THE FOLLOWING: NEMA PB1 AS SCHEDULED, 20" WIDE SECTION, BUSSING AS INDICATED. PROVIDE TYPEWRITTEN BRANCH CIRCUIT DIRECTORY. LOAD CENTERS ARE NOT APPROVED. ALL COMBINATIONS OF EQUIPMENT AND MAIN /BRANCH OVERCURRENT PROTECTION SHALL BE FULLY RATED AIC. 4.04 CIRCUIT BREAKERS: NEMA A81 AS SCHEDULED, BOLT -ON, CENTER TRIP, SWD IF SINGLE POLE, COMMON TRIP IF MULTI -POLE, HACR IF REQUIRED BY LOAD. MATCH EXISTING EQUIPMENT. 4.05 FUSES: UL CLASS J. WHEN FUSING EXISTING EQUIPMENT, FUSES SHALL BE CURRENT LIMITING AND MATCH EXISTING FUSE MANUFACTURER. PROVIDE 3 SPARE OF EACH SIZE AND TYPE INSTALLED. 4.06 MAGNETIC MOTOR STARTER: NEMA 1052, FVNR, SIZE PER MOTOR REQUIREMENTS BUT SIZE 0 MINIMUM, NEMA 3R ENCLOSURE IF OUTDOORS. PROVIDE CLASS 20 HEATERS PER ACTUAL MOTOR NAMEPLATE DATA. PROVIDE 120VAC OR 24VAC FUSED CONTROL CIRCUIT AS REQUIRED. 4.07 MANUAL MOTOR STARTER: NEMA RATED, FHP, SINGLE SPEED, TOGGLE OPERATED, MANUAL RESET OVERLOAD, NEMA 1 ENCLOSURE. 16500 - LIGHTING 5.01 TENANT FURNISHED EQUIPMENT: FOR LIGHT FIXTURES AND AUXILIARY ITEMS SCHEDULED AS FURNISHED BY TENANT, RECEIVE, PROTECT, INSTALL, CLEAN, AND LAMP LIGHT FIXTURES AS SCHEDULED, OR EQUAL. 5.02 CONTRACTOR FURNISHED EQUIPMENT: FOR LIGHT FIXTURES SCHEDULED AS FURNISHED BY CONTRACTOR, FURNISH AND INSTALL COMPLETE, OR APPROVED EQUAL. 5.03 ACCESSORIES: PROVIDE ACCESSORIES, INCIDENTAL MATERIALS, AND MOUNTING HARDWARE AS REQUIRED. 5.04 LOCATION: REFER ALSO TO ARCHITECTURAL DRAWINGS FOR FIXTURE LOCATIONS AND MOUNTING DETAILS. 5.05 INSTALLATION: PROPERLY INSTALL AND SUPPORT ALL FIXTURES PLUMB AND TRUE, AND FREE OF LIGHT LEAKS. CONFORM TO MANUFACTURER'S RECOMMENDATIONS AND INDUSTRY PRACTICE. LEAVE PROTECTIVE FILM IN PLACE ON FIXTURES UNTIL FINAL CLEAN -UP. INSTALL LIGHT FIXTURES IN RATED CEILINGS TO MAINTAIN THE RATING OF CEILING. 5.06 EMERGENCY LIGHTING: PROVIDE AND LOCATE EMERGENCY LIGHTING TO MEET LOCAL REQUIREMENTS. 5.07 FLUORESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ELECTRONIC HPF, RAPID- START, PARALLEL LAMP OPERATION, CBM, TYPE 1, CLASS P, SOUND RATED A, THD<20 %, CCFC 1.5, NAECA COMPLIANT WHERE APPLICABLE, ENERGY SAVING BALLASTS. 5.08 RECESSED INCANDESCENT FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE FMC AND 150 DEGREE C FIXTURE WIRE FROM LAMP HOUSING TO INDEPENDENT BRANCH CIRCUIT OUTLET BOX. 5.09 HID FIXTURES: IF FURNISHED BY CONTRACTOR, PROVIDE ANSI C82.4 COMPLIANT, HPF, ENCAPSULATED BALLASTS, ADVANCE SERIES 73B OR EQUAL. 5.10 FINAL ADJUSTMENT AFTER TRADE FIXTURES ARE INSTALLED BY OTHERS: CLEAN ALL LIGHTING FIXTURES, REPLACE ALL EXPIRED LAMPS, AND ADJUST DIRECTIONAL LIGHTING AS DIRECTED BY TENANT AND ARCHITECT. \S 5.11 SIGN DISCONNECT: PROVIDE DISCONNECT SWITCH IN ACCESSIBLE CEILING SPACE FOR STORE SIGN AND MAKE FINAL CONNECTION. VERIFY LOCATION IN FIELD. SIGN FURNISHED AND INSTALLED BY OTHERS. COORDINATE ALL REQUIREMENTS PRIOR TO BID. 16700 - SYSTEM 7.01 DATA SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS 3/4" MINIMUM EMT RACEWAY SYSTEM WITH PULL WIRE FROM DATA SYSTEM EQUIPMENT LOCATION TO ALL DATA SYSTEM OUTLETS. FOR NON- PLENUM ACCESSIBLE CEILING SPACES, AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEILING SPACE ARE PERMITTED IN LIEU OF CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS, PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND BLANK PLATE. FOR FLOOR OUTLET PROVIDE FLOOR BOX AS ELSEWHERE SPECIFIED AND BLANK PLATE. 7.02 TELEPHONE SYSTEM ROUGH -IN: PROVIDE DEDICATED CONTINUOUS 3/4" MINIMUM EMT RACEWAY SYSTEM WITH PULL WIRE FROM LANDLORD STUB -IN TO BACKBOARD AND FROM BACKBOARD TO ALL TELEPHONE OUTLETS. FOR NON- PLENUM ACCESSIBLE CEILING SPACES, AND WHERE APPROVED BY TENANT, LANDLORD, AND LOCAL AUTHORITY, BUSHED RACEWAY STUBS FROM OUTLET BOXES TO CEILING SPACE ARE PERMITTED IN LIEU OF CONTINUOUS SYSTEM OR AS NOTED. FOR WALL OUTLETS, PROVIDE 4" SQUARE OUTLET BOX WITH SINGLE GANG ADAPTER RING AND TELEPHONE PLATE. FOR FLOOR OUTLET, PROVIDE FLOOR BOX AS ELSEWHERE SPECIFIED AND TELEPHONE PLATE. PROVIDE 3/4" FIRE - TREATED PLYWOOD BACKBOARD OF SIZE REQUIRED FOR TELEPHONE EQUIPMENT. PROMPTLY NOTIFY TENANT WHEN ROUGH -IN INSTALLATION IS COMPLETE. THE FOLLOWING REQUIREMENTS APPLY TO THE PHONE AND DATA INSTALLATION AND CONSTRUCTION PROCESS. 1. CONDUIT MUST BE INSTALLED AND FIRE RATED CAULKING /SEALANT USED AT THE POINT WHERE THE LINE CROSSES THE DEMISING PARTITION AND ENTERS INTO THE SERVICE CORRIDOR (WHICH ARE RATED FOR LIFE SAFETY). THIS IS A REQUIREMENT OF THE FIRE MARSHALL. FOR CONSISTENCY, CONDUIT WILL BE USED ABOVE THE TENANT SPACE, AND THROUGHOUT THE SPACE. CONDUIT IS LIMITED TO 2" DIAMETER FOR PHONE /DATA LINES. 7.03 SECURITY SYSTEM ROUGH -IN: PROVIDE CONTINUOUS RACEWAY SYSTEM WITH PULL WIRE AS INDICATED FOR INSTALLATION OF SECURITY SYSTEMS BY OTHERS. ELECTRICAL LOA D SU A LANDLORD NOTES A. NO BX, AC, OR ROMEX TYPE WIRING ALLOWED. B. ALL CABLING SHALL BE PLENUM RATED. ALL TENANTS SERVED BY LANDLORD'S AIR CONDITIONING UNITS HAVE PLENUM RETURNS. C. ELECTRICAL CONTRACTOR SHALL UTILIZE LANDLORD PROVIDED FUSED DISCONNECT SWITCH LOCATED WITHIN THE TENANT SPACE ON BACK WALL FOR TEMPORARY ELECTRICAL FOR CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY TRANSFORMER AND PANEL AS REQUIRED WITHIN TENANT SPACE. D. NO ATTACHMENT OR SUPPORT FROM ANY ROOF DECK IS ALLOWED. HANGERS, CLAMPS, AND SUPPORTS SHALL BE FASTENED TO BAR JOISTS OR BEAMS ONLY. E. TENANT'S ELECTRICAL CONTRACTOR SHALL FURNISH AND IDENTIFICATION NAMEPLATE ON TENANT'S MAIN DISCONNECT SWITCH IN LANDLORD'S SWITCHBOARD. NAMEPLATES SHALL BE ONE- EIGHTH INCH (1/8" ) THICK PLASTIC, BLACK ON WHITE, WITH ETCHED LETTERS. THE MINIMUM SIZE SHALL BE ONE INCH (1 ") WITH ONLY THE TENANT'S SPACE NUMBER ENGRAVED ON SUCH, PERMANANTLY AFFIXED. v1 vARY LOAD TYPE CONNECT. LOAD (KVA) DEMAND FACTOR DEMAND LOAD (KVA) LIGHTING 4.9 1.25 6.1 SIGN 1.2 1.25 1.5 RECEPTACLES* 7.6 1.0 7.6 WATER HEATER 4.3 1.25 5.4 HVAC ** 6.0 1.0 +0.25 7.5 0 0 3 - Storefront Lighting Storefront Li hq nng - - 8- 1865 TOTAL 24.0 100 28.1 SERVICE SIZING LOAD = 28.1 KVA TOTAL DEMAND LOAD: 28.1 / 0.831 = 34 AMPS TOTAL CONNECTED LOAD: 24.0 / 0.831 = 29 AMPS * 100% OF THE FIRST 1OKVA + 50% OF REMAINING KVA ** 100% + 25% OF LARGEST MOTOR, LARGEST LOAD OF HEATING OR COOLING. • LANDLORD'S SPADE TENANT'S SPACE VERIFY EXISTING FEEDER, 4 #250KCMIL, #4 CND. AL MC CABLE. VERIFY EXISTING 200 AMP, 3 -POLE, 277/480V SERVICE DISCONNECT METER BASE BY LANDLORD. PROVIDE METER AS REQUIRED. COORDINATE WITH ELECTRIC UTILITY. J 200A/ 200AF (EXIST.) 2" C. -4 #3/0, #4 GND. PANEL 'H' 277/480V 3PH, 4W 3/4 "C. -3 #6 Sag PANEL 'L' 120/208V 3PH, 4W TC Panel: H Vo tage: 2771480v, 3P #h. 4w No. Amp /p Not Description Ph Code L VA Code C VA Code R VA Code M VA Code E VA Code K VA Code D VA 1 50/3 Storefront Sign Transformer - A-, 3150 ' 2880 0 0 0 0 0 3 - Storefront Lighting Storefront Li hq nng - - 8- 1865 1980 400 100 2160 0 0 - 5 - 7 - - C - 1100 2160 200 0 2160 0 0 7 20/1 9 Spare - A - Sates Lighting Spare • B - - C - 835 9 20/1 11 Spare - B -- 13 15 2011 2011 20/1 l_ 0 1 Accent Lighting • A - 600 11 20/1 Spare - C - Toilet/Stock Lighting - B - 230 - 15 . %S111111111 2 17 Spare P 0 S Receptacle VAV - A - 180 11!!!: _ {3 __',._ � 3 305 1666 _ T 19 21 4 _15/3 - - B- - - B - _ 305 _ 1666 23 20/1 6 - C - - C - ���= Vijaillkin� MailiiillailliiIIIIIIIIIII 26 305 1666 Protector Receptacles A • 8 20/1 27 Spare - A - Raafio• Rece +tale - 8 • 180 29 20/1 10 2011 Spare - B - 20/1 • Spare • A . 12 20/1 Spare - C - 2011 S. are - B - Through Feed Lug Connection t:, tlE - A - 35 20/1 Spare • C - .._� 37 - B - Spare , A _ 39 41 20/1 20/1 Mil IIME - C - B- - rl Eitt!i Main Breaker Spare - C - - A - 3150 2880 0 305 1666 0 0 20/1 - B- 1865 1980 400 405 3826 0 0 4 - C - 1100 2160 200 305 3826 0 0 Overcurrent Device Notes: Conn KVA phase loads Total - A - -15 - - C - _ i - C - 24.1 8.0 8.5 7.6 Dmd Conn Bus KVA Toads Sales Receptacles 7.6 6.1 Code L - Lighting l 7.0 7.0 Code C - Convenience Receptacles (180 VV) 10 2011 0.6 0.6 Code R - Receptacles (Non Convenience) Panelboard Notes: 1.2 1.0 Code M - Motors L.:, 9, t .1 Mtr ': A = I 915 11.6 9.3 Code E - Electric Heat Sales Receptacles 0.0 0.0 Code K - Kitchen Equip [.IA _ ( loci% 0.0 0.0 Cade ID - Dwelling Units (Hotel/Motel Rooms) 14 20/1 28 24 Total KVA 540 0 Spare KVA . ,j,. ,,. I- 0'-:, SURFACE : Mounting 28 Adjusted KVA (Demand + Spare KVA) 14.000 : Amps AIC Rating 34 Adjusted Amps (Demand + Spare KVA) 1 00 : Amp Rating of Bus 36 High Phase Amps (Demand + Spare KVA) 1 4(9(08 60 : Panel Amp Rating (Min Main or Bus Rating) File Name: Pro'ect Number : Project Name : , T.i+ :,I., v'rr'■ . 480 i , .,, r I , , n.ig, 1 ., .1F Fr +,' , ■ l Panel: L Voltage: 12012O8v, 3Ph, 4w No Amp /p Note Descni bon Ph Code L VA Code C VA Code R VA Code M VA Code E VA Code K VA Code D VA 1 20/1 1,2 Storefront Sign - A - 1200 PER LL, ARCH. J 3 20 /1 1.2 Storefront Lighting Storefront Li hq nng - 13 • - C • 600 1100 5 20/1 1 ,2 7 20/1 Track Lighting - A - 1350 TITLE ELECTRICAL SPECIFICATIONS 9 20/1 Sates Lighting Spare • B - - C - 835 11 20/1 13 15 2011 2011 20/1 l_ 0 1 Accent Lighting • A - 600 _,.......riala Toilet/Stock Lighting - B - 230 _. 15 . %S111111111 17 Spare P 0 S Receptacle • C - - A - 180 11!!!: _ {3 __',._ � 3 is �;j�j• _ T 19 21 20/1 20/1 P ❑ S Rece.tacle - B- 1B0.41�� i�► 23 20/1 I Telephone Board Receptade C - 360 ���= Vijaillkin� MailiiillailliiIIIIIIIIIII 26 20/1 Protector Receptacles A • 360 27 2011 Raafio• Rece +tale - 8 • 180 29 20/1 Spare - C - 31 20/1 • Spare • A . 33 2011 S. are - B - IllrOrgii240 35 20/1 Spare • C - .._� 37 20/1 Spare , A _ 39 41 20/1 20/1 Mil IIME S.are B- :lr_ rl Eitt!i ► `� Spare - C - Li IP- 2 20/1 Cashwrap Receptacle - A - 180 4 20(1 Dashwrap Receptacle • 8 • 180 6 20/1 Cashwrap Receptacle - C - 380 8 20/1 Sales Receptacles • A • 720 10 2011 3 Sales Receptacles - 8 - 720 12 20/1 Sales Receptacles - C - 540 14 20/1 Sales Receptacles • A - 540 16 2011 Ceiling Receptacles - 8 • 200 360 18 20 20/1 20/1 Sales Receptacles • C • 900 Sales Receptacles - A - 900 RF IVFn 22 20/1 Rece•tactesiEWC - 8 • 360 400 200 OF TU -.l A 24 20/1 Timeclock /Sound Sys - C - 26 20/1 Spare - A MAY I) 8 n 8 20118 p 28 20/1 Spare - 8 • 30 20/1 Spare - C - MIii,_ :4iyilM1[ogail 32 20/1 Spare - A - 34 20/1 C 36 6 20/1 ■ Spare Spare - • - A • NM 38 20/1 40 20/2 Water Heater - 8 • 2160 42 - - - C - 2160 Through Feed Lug Connection • A .8 - Main Breaker - A- 3150 2880 0 0 0 0 0 -8• 1865 1980 400 100 2160 0 0 C - 1100 2160 200 0 2160 0 0 Overcurrent Device Notes: Conn kVA phase loads Total - A - -13 - - C - _ I I ,i i i i 18 2 6 0 6 5 5 6 .I; 1 inn Dmd Conn Bus KVA loads 1 7 6 6 1 Code L - Lighting 7 0 7 0 Code C - Convenience Receptacles (180 W) 0 6 0 6 Cade R- Receptacles (Non Convenience) Panelboard Notes: 0 1 0 1 Code M - Motors , !.iii 104) 5 4 4 3 Code E - Electric Heat 0 0 0 0 Code K - Kitchen Equip 1 100"4 0 0 0 0 Code D - Dwelling Units (Hotel Motel Rooms) 21 18 Total KVA 0 Spare KVA . I 0 °� SURFACE Mounting 21 Adjusted KVA (Demand + Spare KVA) 10.000 Amps AIC Rating 58 Adjusted Amps (Dem and + Spare KVA) 100 Amp Rating of Bus I 4/9/08 100 Panel Amp Rating (Min Man or Bus Rating) Fie Name Project Number Project Name 208 ",, 4,, ',;', ilii 1-,l a , PROVIDE NEW TIMECLOCK. SEE KEYNOTE 1/- #4, SHEET E2.0. SHALL ALSO CONTROL: - ENTRY LIGHTING - SHOW WINDOW RECEPTACLES. - SHOW WINDOW LIGHTING. 1- 1/2 "C. -4 #1, #6 GND. LANDLORD'S EXISTING 480/277V, 3PH, 4W PANEL, 1B RISER IIAGRA v NO SCALE ELECTRICAL CONTRACTOR SHALL VISIT SITE, NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO BID. PROVIDE 30KVA TRANSFORMER: 3 -0, 3 -WIRE PRIMARY, 120/208 VOLT, 3 -0, 4 -WIRE SECONDARY, 3% IMPED. 1 #6 GROUND TO BLDG. STEEL SHORT CIRCUIT CALCULATION: 18,437A AVAILABLE AT PANEL 1B, APPROX. 20' FROM PANEL "H ", FEEDER: #250 KCMIL MC CABLE f =(1 .732 *20 *18437)/(480 *12797) =0.1 M= 1/1 +.1 =0.91 A.I.0 @ PANEL "H" =1843.7 *.91 =1 6,706 CONCEPT BY: 3 Dunham Associates, Inc. 0) 0 0 VALLEY VIEW 1` 0 tT 0 FAx 612.465.7551 PHONE 612.465.7550 PHONE 952-944-7576 dunhameng.ccm IF YOU HAVE ANY QUESTIONS REGARDING THE ELECTRICAL PLANS PLEASE CALL THE ELECTRICAL DESIGNER: DESIGNER: PATRICK DAVITT 612 - 465 -7677 OR SUPERVISOR: RON MATHESON 612 -465 -7673 © 2007 L8M ASSOCIATES, LTD. ALL RIGHTS RESERVED ww Z 0 N LLi. d' Z� CC J LL O O U� I-1_O w in L.0 O%- J U] CO 0- PROJECT SELECT COMFORT SOUTHCENTER MALL SUITE # 1005 633 SOUTHCENTER PARKWAY TUKWILA, WA 98188 PROJECT NO. 408865 -13 n DATE 0 m Q z 0 rn w ct PER LL, ARCH. J 0 0 INC) W 1- w w z to TITLE ELECTRICAL SPECIFICATIONS